  1. Impact of 18F-Fluoro-2-Deoxyglucose Positron Emission Tomography on Treatment Strategy and Radiotherapy Planning for Stage I-II Hodgkin Disease: A Prospective Multicenter Study

    SciTech Connect

    Pommier, Pascal; Dussart, Sophie; Girinsky, Theodore; Chabaud, Sylvie; Lagrange, Jean Leon; Nguyen, Tan Dat; Beckendorff, Veronique; D'Hombres, Anne; Artignan, Xavier; Bondiau, Pierre Yves; Carrie, Christian; Giammarile, Francesco

    2011-03-01

    Purpose: To quantify the impact of preradiotherapy 18F-fluoro-2-deoxyglucose positron-emission tomography (FDG-PET) on treatment strategy and radiotherapy planning for patients with Stage I/II Hodgkin disease included in a large prospective multicenter study. Patients and Methods: Conventional computed tomography and FDG-PET were performed just before the planned radiotherapy. The radiotherapy plan was first elaborated under blinded conditions for FDG-PET data. Then, the medical staff was asked to confirm or not confirm the treatment strategy and, if appropriate, to modify the radiotherapy plan based on additional information from FDG-PET. Results: Between January 2004 and January 2006, 137 patients were included (124 were available for analysis) in 11 centers (108 adults, 16 children). All but 1 patient had received chemotherapy before inclusion. Prechemotherapy work-up included FDG-PET for 61 patients, and data were available for elaboration of the first radiotherapy plan. Based on preradiotherapy FDG-PET data, the radiotherapy was cancelled in 6 patients (4.8%), and treatment plan modifications occurred in 16 patients (12.9%): total dose (11 patients), CTV volume (5 patients), number of beam incidences (6 patients), and number of CTV (6 patients). The concordance between the treatment strategies with or without preradiotherapy FDG-PET was 82.3%. Concordance results were not significantly different when prechemotherapy PET-CT information was available. Conclusion: Preradiotherapy FDG-PET for treatment planning in Hodgkin lymphoma may lead to significant modification of the treatment strategy and the radiotherapy planning in patients with Stage I or II Hodgkin disease, even in those who have undergone FDG-PET as part of the prechemotherapy work-up.

  2. Radiation Treatment Planning Using Positron Emission and Computed Tomography for Lung and Pharyngeal Cancers: A Multiple-Threshold Method for [{sup 18}F]Fluoro-2-Deoxyglucose Activity

    SciTech Connect

    Okubo, Mitsuru; Nishimura, Yasumasa; Nakamatsu, Kiyoshi; Okumura, Masahiko R.T.; Shibata, Toru; Kanamori, Shuichi; Hanaoka, Kouhei R.T.; Hosono, Makoto

    2010-06-01

    Purpose: Clinical applicability of a multiple-threshold method for [{sup 18}F]fluoro-2-deoxyglucose (FDG) activity in radiation treatment planning was evaluated. Methods and Materials: A total of 32 patients who underwent positron emission and computed tomography (PET/CT) simulation were included; 18 patients had lung cancer, and 14 patients had pharyngeal cancer. For tumors of <=2 cm, 2 to 5 cm, and >5 cm, thresholds were defined as 2.5 standardized uptake value (SUV), 35%, and 20% of the maximum FDG activity, respectively. The cervical and mediastinal lymph nodes with the shortest axial diameter of >=10 mm were considered to be metastatic on CT (LNCT). The retropharyngeal lymph nodes with the shortest axial diameter of >=5 mm on CT and MRI were also defined as metastatic. Lymph nodes showing maximum FDG activity greater than the adopted thresholds for radiation therapy planning were designated LNPET-RTP, and lymph nodes with a maximum FDG activity of >=2.5 SUV were regarded as malignant and were designated LNPET-2.5 SUV. Results: The sizes of gross tumor volumes on PET (GTVPET) with the adopted thresholds in the axial plane were visually well fitted to those of GTV on CT (GTVCT). However, the volumes of GTVPET were larger than those of GTVCT, with significant differences (p < 0.0001) for lung cancer, due to respiratory motion. For lung cancer, the numbers of LNCT, LNPET-RTP, and LNPET-2.5 SUV were 29, 28, and 34, respectively. For pharyngeal cancer, the numbers of LNCT, LNPET-RTP, and LNPET-2.5 SUV were 14, 9, and 15, respectively. Conclusions: Our multiple thresholds were applicable for delineating the primary target on PET/CT simulation. However, these thresholds were inaccurate for depicting malignant lymph nodes.

  3. Evaluation of 18-F-fluoro-2-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) as a staging and monitoring tool for dogs with stage-2 splenic hemangiosarcoma – A pilot study

    PubMed Central

    Winter, Amber L.; Stuebner, Kathleen; Scott, Ruth; Ober, Christopher P.; Anderson, Kari L.; Feeney, Daniel A.; Vallera, Daniel A.; Koopmeiners, Joseph S.; Modiano, Jaime F.; Froelich, Jerry

    2017-01-01

    Positron Emission Tomography-Computed Tomography (PET-CT) is routinely used for staging and monitoring of human cancer patients and is becoming increasingly available in veterinary medicine. In this study, 18-fluorodeoxyglucose (18FDG)-PET-CT was used in dogs with naturally occurring splenic hemangiosarcoma (HSA) to assess its utility as a staging and monitoring modality as compared to standard radiography and ultrasonography. Nine dogs with stage-2 HSA underwent 18FDG-PET-CT following splenectomy and prior to commencement of chemotherapy. Routine staging (thoracic radiography and abdominal ultrasonography) was performed prior to 18FDG-PET-CT in all dogs. When abnormalities not identified on routine tests were noted on 18FDG-PET-CT, owners were given the option to repeat a PET-CT following treatment with eBAT. A PET-CT scan was repeated on Day 21 in three dogs. Abnormalities not observed on conventional staging tools, and most consistent with malignant disease based on location, appearance, and outcome, were detected in two dogs and included a right atrial mass and a hepatic nodule, respectively. These lesions were larger and had higher metabolic activity on the second scans. 18FDG-PET-CT has potential to provide important prognostic information and influence treatment recommendations for dogs with stage-2 HSA. Additional studies will be needed to precisely define the value of this imaging tool for staging and therapy monitoring in dogs with this and other cancers. PMID:28222142

  4. Clinically determined type of 18F-fluoro-2-deoxyglucose uptake as an alternative prognostic marker in resectable pancreatic cancer

    PubMed Central

    Chong, Jae Uk; Hwang, Ho Kyoung; Lee, Jin Ho; Yun, Mijin; Kang, Chang Moo; Lee, Woo Jung

    2017-01-01

    Purpose To investigate the association between clinical PET (positron emission tomography) type and oncologic outcome in resectable pancreatic cancer. Methods Between January 2008 and October 2012, patients who underwent potentially curative resection for resectable pancreatic ductal adenocarcinoma without neoadjuvant treatment were retrospectively investigated. Clinical PET type was defined as follows: pancreatic cancer with similar 18FDG uptake to renal calyx was determined as kidney-type (K-type), and relatively lower 18FDG uptake than that of renal calyx was regarded as Non-K type. Results A total of 53 patients were enrolled. After agreement-based reclassification, agreement based K-type (aK-type) was noted in 34 patients (64.2%), and agreement based Non-K type (aNon K-type) was found in 19 patients (35.8%). There was a significant difference between aK-type and aNon K-type pancreatic cancer (tumor size (P = 0.030), adjusted CA 19–9 (P = 0.007), maximum standard uptake value (SUVmax,P<0.001), metabolic tumor volume (MTV2.5, P<0.001), total lesion glycolysis (TLG, P<0.001)). K-type pancreatic cancer (n = 31) showed a significantly shorter disease-free time compared with Non-K type (n = 16) (10.8 vs. 24.1 months, P = 0.013). It was also noted that aK-type showed inferior disease-free survival to that of aNon-K type pancreatic cancer (11.9 vs. 28.6 months, P = 0.012). Conclusions Clinical PET type is a reliable clinical marker to estimate aggressive tumor biology and can be utilized in predicting tumor recurrence and necessity for postoperative chemotherapy. PMID:28235029

  5. Neuro-imaging and positron emission tomography of congenital homonymous hemianopsia.

    PubMed

    Bosley, T M; Kiyosawa, M; Moster, M; Harbour, R; Zimmerman, R; Savino, P J; Sergott, R C; Alavi, A; Reivich, M

    1991-04-15

    Congenital homonymous hemianopsia is an uncommon asymptomatic visual field defect discovered typically in young adult life that is caused by a diverse group of insults to the retrochiasmal afferent visual system occurring prenatally, at birth, or during early childhood. We treated eight patients with congenital homonymous hemianopsia; seven with damage involving the optic radiations and one with an abnormality of the optic tract. We performed positron emission tomography using 18F-fluoro-2-deoxyglucose on two patients with dense homonymous hemianopsias, lesions of the contralateral optic radiations, and largely intact occipital cortex. These studies showed minimal abnormalities in resting visual cortex glucose metabolism of the affected visual cortex.

  6. [{sup 18}F]FDG-Positron Emission Tomography Coregistration With Computed Tomography Scans for Radiation Treatment Planning of Lymphoma and Hematologic Malignancies

    SciTech Connect

    Terezakis, Stephanie A.; Hunt, Margie A.; Kowalski, Alexander; McCann, Patrick; Schmidtlein, C. Ross; Reiner, Anne; Goenen, Mithat; Kirov, Assen S.; Gonzales, Anne Marie; Schoeder, Heiko; Yahalom, Joachim

    2011-11-01

    Purpose: Positron emission-tomography (PET) using 2-[{sup 18}F]fluoro-2-deoxyglucose (FDG-PET) increases sensitivity and specificity of disease detection in lymphoma and thus is standard in lymphoma management. This study examines the effects of coregistering FDG-PET and computed tomography (CT) (PET/CT) scans on treatment planning for lymphoma patients. Methods and Materials: Twenty-nine patients (30 positive PET scans) underwent PET/CT treatment planning from July 2004 to February 2007 and were retrospectively studied. For each patient, gross tumor volume was blindly contoured on the CT-only and PET/CT studies by a radiation oncologist. Treatment plans were generated for both the CT-only and PET/CT planning target volumes (PTVs) for all patients. Normal tissue doses and PTV coverage were evaluated using dose--volume histograms for all sites. Results: Thirty-two treatment sites were evaluated. Twenty-one patients had non-Hodgkin lymphoma, 5 patients had Hodgkin lymphoma, and 3 patients had plasma cell neoplasms. Previously undetected FDG-avid sites were identified in 3 patients during PET/CT simulation, resulting in one additional treatment field. Due to unexpected PET/CT simulation findings, 2 patients did not proceed with radiation treatment. The addition of PET changed the volume of 23 sites (72%). The PTV was increased in 15 sites (47%) by a median of 11% (range, 6-40%) and reduced in 8 sites (25%) by a median of 20% (range, 6%-75%). In six (19%) replanned sites, the CT-based treatment plan would not have adequately covered the PTV defined by PET/CT. Conclusions: Incorporation of FDG-PET into CT-based treatment planning for lymphoma patients resulted in considerable changes in management, volume definition, and normal tissue dosimetry for a significant number of patients.

  7. 68Ga-prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography for Prostate Cancer Imaging: A Narrative Literature Review

    PubMed Central

    Oliveira, Jose M.; Gomes, Catarina; Faria, Diogo B.; Vieira, Tiago S.; Silva, Fernando A.; Vale, Joana; Pimentel, Francisco L.

    2017-01-01

    The 68Ga-prostate-specific membrane antigen ( 68Ga-PSMA) has been recently developed to be used, as a ligand, in positron emission tomography/computed tomography (PET/CT) prostate cancer imaging, to detect prostate disease. The main objective of this review was to collect data and findings from other studies and articles to assess, theoretically, if 68GA-PSMA PET/CT is a more appropriate prostate cancer diagnostic technique in comparison with others available such as CT, 18F-fluoro-2-deoxyglucose PET/CT, or 18F-fluoromethylcholine ( 18F-choline) PET/CT. For that purpose, PubMed, the online scientific articles’ database, was consulted where the keywords “PSMA” and “PET” were used to find relevant articles. The clinicaltrials.gov, clinical trials’ database, was also consulted where the keywords “68Ga-PSMA” and “prostate” were used to search clinical trials. Based on the reviewed scientific literature, several studies were conducted to assess and compare the 68Ga-PSMA PET/CT detection rate in prostate cancer with other available techniques. One of those studies, conducted by Giesel et al., concluded, within study sample, that 75% of patients with lymph nodes detected by 68Ga-PSMA PET/CT would have not been identified using other conventional morphological criteria based techniques. In Eiber et al.'s study, 68Ga-PSMA PET detected prostatic disease findings in 67% of patients with prostate-specific antigen levels <1 ng/mL, when compared with choline-based PET that presented detection rates between 19% and 36%. In Bluemel et al.'s study, 68Ga-PSMA identified positive prostatic disease in 43.8% of the patients with negative findings in F-choline PET/CT. Findings from this review demonstrate that 68Ga-PSMA PET/C is more effective in detecting metastases, lymph nodes, and recurrent prostate cancer when compared to 18F-choline-based PET/CT and CT. 68Ga-PSMA PET/CT presents also more imaging contrast and can be more cost-effective. 68Ga-PSMA has already

  8. Quantitative techniques in 18FDG PET scanning in oncology.

    PubMed

    Castell, F; Cook, G J R

    2008-05-20

    The clinical applications of (18)F-fluoro-2-deoxyglucose ((18)FDG) positron emission tomography (PET) in oncology are becoming established. While simple static scanning techniques are used for the majority of routine clinical examinations, increasing use of PET in clinical trials to monitor treatment response with (18)FDG and novel tracers reflecting different pharmacodynamic end points, often necessitates a more complex and quantitative analysis of radiopharmaceutical kinetics. A wide range of PET analysis techniques exist, ranging from simple visual analysis and semiquantitative methods to full dynamic studies with kinetic analysis. These methods are discussed, focusing particularly on the available methodologies that can be utilised in clinical trials.

  9. Positron Emission Tomography (PET)

    DOE R&D Accomplishments Database

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  10. Positron Emission Tomography (PET)

    SciTech Connect

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  11. Positron emission mammography imaging

    SciTech Connect

    Moses, William W.

    2003-10-02

    This paper examines current trends in Positron Emission Mammography (PEM) instrumentation and the performance tradeoffs inherent in them. The most common geometry is a pair of parallel planes of detector modules. They subtend a larger solid angle around the breast than conventional PET cameras, and so have both higher efficiency and lower cost. Extensions to this geometry include encircling the breast, measuring the depth of interaction (DOI), and dual-modality imaging (PEM and x-ray mammography, as well as PEM and x-ray guided biopsy). The ultimate utility of PEM may not be decided by instrument performance, but by biological and medical factors, such as the patient to patient variation in radiotracer uptake or the as yet undetermined role of PEM in breast cancer diagnosis and treatment.

  12. A Case of Gastric Cancer with Situs Inversus Totalis

    PubMed Central

    Suh, Byoung Jo

    2017-01-01

    Situs inversus totalis (SIT) is a rare congenital anomaly that refers to a completely reversed location of the abdominal and thoracic organs. We report the case of 50-year-old man with gastric cancer and SIT who was diagnosed during a screening esophagogastroduodenoscopy. A chest X-ray, abdominopelvic computed tomography, and 18F-fluoro2-deoxyglucose-D-glucose-positron emission tomography scans revealed SIT. We performed a radical subtotal gastrectomy with D2 lymph node dissection. Advanced surgical skill is required to perform a precise lymphadenectomy in a patient with SIT by visualizing the exact mirror image of the anatomy during the operation. The patient had an uneventful intra- and postoperative course and was followed up at the outpatient department without any evidence of recurrence. In conclusion, surgery in a patient with gastric cancer and SIT can be safely performed by paying attention to the inverted anatomic structures during the operation. PMID:28203176

  13. State-Of-The-Art and Recent Advances in Quantification for Therapeutic Follow-Up in Oncology Using PET

    PubMed Central

    Carlier, Thomas; Bailly, Clément

    2015-01-01

    18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography (PET) is an important tool in oncology. Its use has greatly progressed from initial diagnosis to staging and patient monitoring. The information derived from 18F-FDG-PET allowed the development of a wide range of PET quantitative analysis techniques ranging from simple semi-quantitative methods like the standardized uptake value (SUV) to “high order metrics” that require a segmentation step and additional image processing. In this review, these methods are discussed, focusing particularly on the available methodologies that can be used in clinical trials as well as their current applications in international consensus for PET interpretation in lymphoma and solid tumors. PMID:26090365

  14. Positron emission tomography wrist detector

    DOEpatents

    Schlyer, David J.; O'Connor, Paul; Woody, Craig; Junnarkar, Sachin Shrirang; Radeka, Veljko; Vaska, Paul; Pratte, Jean-Francois

    2006-08-15

    A method of serially transferring annihilation information in a compact positron emission tomography (PET) scanner includes generating a time signal representing a time-of-occurrence of an annihilation event, generating an address signal representing a channel detecting the annihilation event, and generating a channel signal including the time and address signals. The method also includes generating a composite signal including the channel signal and another similarly generated channel signal concerning another annihilation event. An apparatus that serially transfers annihilation information includes a time signal generator, address signal generator, channel signal generator, and composite signal generator. The time signal is asynchronous and the address signal is synchronous to a clock signal. A PET scanner includes a scintillation array, detection array, front-end array, and a serial encoder. The serial encoders include the time signal generator, address signal generator, channel signal generator, and composite signal generator.

  15. Addiction Studies with Positron Emission Tomography

    ScienceCinema

    Joanna Fowler

    2016-07-12

    Brookhaven scientist Joanna Fowler describes Positron Emission Technology (PET) research at BNL which for the past 30 years has focused in the integration of basic research in radiotracer chemistry with the tools of neuroscience to develop new scientific

  16. Addiction Studies with Positron Emission Tomography

    SciTech Connect

    Joanna Fowler

    2008-10-13

    Brookhaven scientist Joanna Fowler describes Positron Emission Technology (PET) research at BNL which for the past 30 years has focused in the integration of basic research in radiotracer chemistry with the tools of neuroscience to develop new scientific

  17. Positron annihilation induced Auger electron emission

    SciTech Connect

    Weiss, A.; Jibaly, M.; Lei, Chun; Mehl, D.; Mayer, R.; Lynn, K.G.

    1988-01-01

    We report on measurements of Auger electron emission from Cu and Fe due to core hole excitations produced by the removal of core electrons by matter-antimatter annihilation. Estimates are developed of the probability of positrons annihilating with a 3p electron in these materials. Several important advantages of Positron annihilation induced Auger Electron Spectroscopy (PAES) for surface analysis are suggested. 10 refs., 2 figs.

  18. Advanced Instrumentation for Positron Emission Tomography [PET

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  19. Advanced instrumentation for Positron Emission Tomography

    SciTech Connect

    Derenzo, S.E.; Budinger, T.F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underly modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost. 71 refs., 3 figs., 3 tabs.

  20. Positron emission tomography - a new approach to brain chemistry

    SciTech Connect

    Jacobson, H.G.

    1988-11-11

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission.

  1. Positron emission tomography: An overview

    PubMed Central

    Shukla, A. K.; Kumar, Utham

    2006-01-01

    The rate of glucose utilization in tumor cells is significantly enhanced as compared to normal cells and this biochemical characteristic is utilized in PET imaging using FDG as a major workhorse. The PET systems as well as cyclotrons producing positron emitting radiopharmaceuticals have undergone continuous technological refinements. While PET (CT) systems enable fusion images as well as precise attenuation correction, the self-shielded cyclotrons developed provide dedicated systems for in-house production of a large number of PET radiopharmaceuticals. The application of PET images in oncology includes those of pulmonary, colorectal, breast, lymphoma, head & neck, bone, ovarian and GI cancers. The PET has been recognized as promising diagnostic tool to predict biological and physiological changes at the molecular level and hence offer a potential area for future applications including Stem Cell research. PMID:21206635

  2. Positron Emission Tomography Imaging of Hypoxia

    PubMed Central

    Lapi, Suzanne E.; Voller, Thomas F.; Welch, Michael J.

    2009-01-01

    Synopsis Hypoxia imaging has applications in functional recovery in ischemic events such as stroke and myocardial ischemia, but especially in tumors in which hypoxia can be predictive of treatment response and overall prognosis. Recently there has been development of imaging agents utilizing positron emission tomography for non-invasive imaging of hypoxia. Many of these PET agents have come to the forefront of hypoxia imaging. Halogenated PET nitroimidazole imaging agents labeled with 18F (t1/2 = 110 m) and 124I (t1/2 = 110 m) have been under investigation for the last 25 years, with radiometal agents (64Cu-ATSM) being developed more recently. This review focuses on these positron emission tomography imaging agents for hypoxia. PMID:20046923

  3. Imaging Prostate Cancer with Positron Emission Tomography

    DTIC Science & Technology

    2014-07-01

    AD_________________ Award Number: W81XWH-13-1-0125 TITLE: Imaging Prostate Cancer with Positron Emission Tomography...ABOVE ADDRESS. 1. REPORT DATE 2014 2. REPORT TYPE Annual 3. DATES COVERED 01 Sept 2013-31 Aug 2014 4. TITLE AND SUBTITLE Imaging Prostate Cancer ...proposal is to develop peptide based radiopharmaceuticals and evaluate them as PET imaging agents in preclinical animal models of prostate cancer

  4. Feasibility study for positron emission mammography.

    PubMed

    Thompson, C J; Murthy, K; Weinberg, I N; Mako, F

    1994-04-01

    A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.

  5. Positron emission tomography (PET) for cholangiocarcinoma

    PubMed Central

    Breitenstein, S.; Apestegui, C.

    2008-01-01

    The combination of positron emission tomography (PET) with computed tomography (PET-CT) provides simultaneous metabolic and anatomic information on tumors in the same imaging session. Sensitivity of PET/PET-CT is higher for intrahepatic (>90%) than for extrahepatic cholangiocarcinoma (CCA) (about 60%). The detection rate of distant metastasis is 100%. PET, and particularly PET-CT, improves the results and impacts on the oncological management in CCA compared with other imaging modalities. Therefore, PET-CT is recommended in the preoperative staging of intrahepatic (strength of recommendation: moderate) and extrahepatic (strength of recommendation: low) CCA. PMID:18773069

  6. Positron Emission Tomography: Its 65 years

    NASA Astrophysics Data System (ADS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-04-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, pre-clinical and hybrid scanners (, PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  7. Positron Emission Tomography: A Basic Analysis

    NASA Astrophysics Data System (ADS)

    Kerbacher, M. E.; Deaton, J. W.; Phinney, L. C.; Mitchell, L. J.; Duggan, J. L.

    2007-10-01

    Positron Emission Tomography is useful in detecting biological abnormalities. The technique involves attaching radiotracers to a material used inside the body, in many cases glucose. Glucose is absorbed most readily in areas of unusual cell growth or uptake of nutrients so through natural processes the treated glucose highlights regions of tumors and other degenerative disorders such as Alzheimer's disease. The higher the concentration of isotopes, the more dynamic the area. Isotopes commonly used as tracers are 11C, 18F, 13N, and 15O due to their easy production and short half-lives. Once the tracers have saturated an area of tissue they are detected using coincidence detectors collinear with individual isotopes. As the isotope decays it emits a positron which, upon annihilating an electron, produces two oppositely directioned gamma rays. The PET machine consists of several pairs of detectors, each 180 degrees from their partner detector. When the oppositely positioned detectors are collinear with the area of the isotope, a computer registers the location of the isotope and can compile an image of the activity of the highlighted area based on the position and strength of the isotopes.

  8. Positron Emission Tomography of the Heart

    DOE R&D Accomplishments Database

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  9. Compact conscious animal positron emission tomography scanner

    DOEpatents

    Schyler, David J.; O'Connor, Paul; Woody, Craig; Junnarkar, Sachin Shrirang; Radeka, Veljko; Vaska, Paul; Pratte, Jean-Francois; Volkow, Nora

    2006-10-24

    A method of serially transferring annihilation information in a compact positron emission tomography (PET) scanner includes generating a time signal for an event, generating an address signal representing a detecting channel, generating a detector channel signal including the time and address signals, and generating a composite signal including the channel signal and similarly generated signals. The composite signal includes events from detectors in a block and is serially output. An apparatus that serially transfers annihilation information from a block includes time signal generators for detectors in a block and an address and channel signal generator. The PET scanner includes a ring tomograph that mounts onto a portion of an animal, which includes opposing block pairs. Each of the blocks in a block pair includes a scintillator layer, detection array, front-end array, and a serial encoder. The serial encoder includes time signal generators and an address signal and channel signal generator.

  10. Tumor Quantification in Clinical Positron Emission Tomography

    PubMed Central

    Bai, Bing; Bading, James; Conti, Peter S

    2013-01-01

    Positron emission tomography (PET) is used extensively in clinical oncology for tumor detection, staging and therapy response assessment. Quantitative measurements of tumor uptake, usually in the form of standardized uptake values (SUVs), have enhanced or replaced qualitative interpretation. In this paper we review the current status of tumor quantification methods and their applications to clinical oncology. Factors that impede quantitative assessment and limit its accuracy and reproducibility are summarized, with special emphasis on SUV analysis. We describe current efforts to improve the accuracy of tumor uptake measurements, characterize overall metabolic tumor burden and heterogeneity of tumor uptake, and account for the effects of image noise. We also summarize recent developments in PET instrumentation and image reconstruction and their impact on tumor quantification. Finally, we offer our assessment of the current development needs in PET tumor quantification, including practical techniques for fully quantitative, pharmacokinetic measurements. PMID:24312151

  11. Positron Emission Tomography with improved spatial resolution

    SciTech Connect

    Drukier, A.K.

    1990-04-01

    Applied Research Corporation (ARC) proposed the development of a new class of solid state detectors called Superconducting Granular Detectors (SGD). These new detectors permit considerable improvements in medical imaging, e.g. Positron Emission Tomography (PET). The biggest impact of this technique will be in imaging of the brain. It should permit better clinical diagnosis of such important diseases as Altzheimer's or schizophrenia. More specifically, we will develop an improved PET-imager; a spatial resolution 2 mm may be achievable with SGD. A time-of-flight capability(t {approx} 100 psec) will permit better contrast and facilitate 3D imaging. In the following, we describe the results of the first 9 months of the development.

  12. Instrumentation optimization for positron emission mammography

    SciTech Connect

    Moses, William W.; Qi, Jinyi

    2003-06-05

    The past several years have seen designs for PET cameras optimized to image the breast, commonly known as Positron Emission Mammography or PEM cameras. The guiding principal behind PEM instrumentation is that a camera whose field of view is restricted to a single breast has higher performance and lower cost than a conventional PET camera. The most common geometry is a pair of parallel planes of detector modules, although geometries that encircle the breast have also been proposed. The ability of the detector modules to measure the depth of interaction (DOI) is also a relevant feature. This paper finds that while both the additional solid angle coverage afforded by encircling the breast and the decreased blurring afforded by the DOI measurement improve performance, the ability to measure DOI is more important than the ability to encircle the breast.

  13. Recent Developments in Positron Emission Tomography (PET) Instrumentation

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.

  14. Recent developments in positron emission tomography (PET) instrumentation

    SciTech Connect

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  15. Data acquisition with a positron emission tomograph

    SciTech Connect

    Freifelder, R.; Karp, J.S.

    1997-12-31

    Positron Emission Tomography (PET) is a clinical imaging modality used in Nuclear Medicine. PET measures functionality rather than anatomical features and is therefore invaluable in the treatment of diseases which are characterized by functional changes in organs rather than anatomical changes. Typical diseases for which PET is used are cancer, epilepsy, and heart disease. While the scanners are not very complex, the performance demands on the devices are high. Excellent spatial resolution, 4-5 mm, and high sensitivity are key to maintaining high image quality. Compensation or suppression of scattered radiation is also necessary for good image quality. The ability to acquire data under high counting rates is also necessary in order to minimize the injected dose to the patient, minimize the patient`s time in the scanner, and finally to minimize blurring due to patient motion. We have adapted various techniques in our data acquisition system which will be reported on in this talk. These include pulse clipping using lumped delay lines, flash ADCs with short sampling time, the use of a local positioning algorithm to limit the number of data words being used in subsequent second level software triggers and calculations, and finally the use of high speed dedicated calculator boards for on-line rebinning and reduction of the data. Modifications to the system to allow for transmission scanning will also be discussed.

  16. Positron emission tomography in generalized seizures

    SciTech Connect

    Theodore, W.H.; Brooks, R.; Margolin, R.; Patronas, N.; Sato, S.; Porter, R.J.; Mansi, L.; Bairamian, D.; DiChiro, G.

    1985-05-01

    The authors used /sup 18/F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to study nine patients with clinical absence or generalized seizures. One patient had only absence seizures, two had only generalized tonic-clonic seizures, and six had both seizure types. Interictal scans in eight failed to reveal focal or lateralized hypometabolism. No apparent abnormalities were noted. Two patients had PET scans after isotope injection during hyperventilation-induced generalized spike-wave discharges. Diffusely increased metabolic rates were found in one compared with an interictal scan, and in another compared with control values. Another patient had FDG injected during absence status: EEG showed generalized spike-wave discharges (during which she was unresponsive) intermixed with slow activity accompanied by confusion. Metabolic rates were decreased, compared with the interictal scan, throughout both cortical and subcortical structures. Interictal PET did not detect specific anatomic regions responsible for absence seizure onset in any patient, but the results of the ictal scans did suggest that pathophysiologic differences exist between absence status and single absence attacks.

  17. Amorphous silicon detectors in positron emission tomography

    SciTech Connect

    Conti, M. Lawrence Berkeley Lab., CA ); Perez-Mendez, V. )

    1989-12-01

    The physics of the detection process is studied and the performances of different Positron Emission Tomography (PET) system are evaluated by theoretical calculation and/or Monte Carlo Simulation (using the EGS code) in this paper, whose table of contents can be summarized as follows: a brief introduction to amorphous silicon detectors and some useful equation is presented; a Tantalum/Amorphous Silicon PET project is studied and the efficiency of the systems is studied by Monte Carlo Simulation; two similar CsI/Amorphous Silicon PET projects are presented and their efficiency and spatial resolution are studied by Monte Carlo Simulation, light yield and time characteristics of the scintillation light are discussed for different scintillators; some experimental result on light yield measurements are presented; a Xenon/Amorphous Silicon PET is presented, the physical mechanism of scintillation in Xenon is explained, a theoretical estimation of total light yield in Xenon and the resulting efficiency is discussed altogether with some consideration of the time resolution of the system; the amorphous silicon integrated electronics is presented, total noise and time resolution are evaluated in each of our applications; the merit parameters {epsilon}{sup 2}{tau}'s are evaluated and compared with other PET systems and conclusions are drawn; and a complete reference list for Xenon scintillation light physics and its applications is presented altogether with the listing of the developed simulation programs.

  18. The Role of Chemistry in Positron Emission Tomography.

    ERIC Educational Resources Information Center

    Feliu, Anthony L.

    1988-01-01

    Investigates use of positron emission tomography (PET) to study in-vivo metabolic processes. Discusses methodology of PET and medical uses. Outlines the production of different radioisotopes used in PET radiotracers. Includes selected bibliography. (ML)

  19. Positron Emission Mammography with Multiple Angle Acquisition

    SciTech Connect

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FDG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three- dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  20. Positron Emission Mammography with Multiple Angle Acquisition

    SciTech Connect

    Mark F. Smith; Stan Majewski; Raymond R. Raylman

    2002-11-01

    Positron emission mammography (PEM) of F-18 fluorodeoxyglucose (FbG) uptake in breast tumors with dedicated detectors typically has been accomplished with two planar detectors in a fixed position with the breast under compression. The potential use of PEM imaging at two detector positions to guide stereotactic breast biopsy has motivated us to use PEM coincidence data acquired at two or more detector positions together in a single image reconstruction. Multiple angle PEM acquisition and iterative image reconstruction were investigated using point source and compressed breast phantom acquisitions with 5, 9, 12 and 15 mm diameter spheres and a simulated tumor:background activity concentration ratio of 6:1. Image reconstruction was performed with an iterative MLEM algorithm that used coincidence events between any two detector pixels on opposed detector heads at each detector position. This present study compared two acquisition protocols: 2 angle acquisition with detector angular positions of -15 and +15 degrees and 11 angle acquisition with detector positions spaced at 3 degree increments over the range -15 to +15 degrees. Three-dimensional image resolution was assessed for the point source acquisitions, and contrast and signal-to-noise metrics were evaluated for the compressed breast phantom with different simulated tumor sizes. Radial and tangential resolutions were similar for the two protocols, while normal resolution was better for the 2 angle acquisition. Analysis is complicated by the asymmetric point spread functions. Signal- to-noise vs. contrast tradeoffs were better for 11 angle acquisition for the smallest visible 9 mm sphere, while tradeoff results were mixed for the larger and more easily visible 12 mm and 15 mm diameter spheres. Additional study is needed to better understand the performance of limited angle tomography for PEM. PEM tomography experiments with complete angular sampling are planned.

  1. Hodgkin's lymphoma--patient's assessment and staging.

    PubMed

    Gospodarowicz, Mary K

    2009-01-01

    Hodgkin's lymphoma is one of the most curable malignancies today. But treatment is associated with significant toxicity. The objective of high-quality management is to minimize treatment exposure while maximizing cure of disease. Principles of cancer staging and patient's assessment taxonomy are important to improve communication. An orderly patient evaluation and systematic recording of disease extent using the Ann Arbor classification forms the basis for treatment decision, response assessment, and clinical trials. The practice of staging in Hodgkin's lymphoma evolved over the past 40 years from clinical examination and plain imaging to modern anatomic and functional imaging. Although useful in the past, staging laparotomy, lymphangiograms, and Gallium scintigraphy have now been abandoned. Computerized tomography combined with 2-[18F]fluoro-2-deoxyglucose-positron emission tomography form the basis for anatomic disease extent assessment. Although patients' evaluation and staging at diagnosis are important, the management of Hodgkin's lymphoma involves a complex series of algorithms requiring interim and overall response assessment, careful follow-up, repeat assessment, and salvage management of recurrent disease.

  2. Positron emission tomographic imaging of tumors using monoclonal antibodies

    SciTech Connect

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  3. 77 FR 71802 - Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ... ``Investigational New Drug Applications for Positron Emission Tomography (PET) Drugs.'' The guidance is intended to assist manufacturers of PET drugs in submitting investigational new drug applications (INDs). DATES... guidance entitled ``Investigational New Drug Applications for Positron Emission Tomography (PET)...

  4. Positron Emission Tomography: Human Brain Function and Biochemistry.

    ERIC Educational Resources Information Center

    Phelps, Michael E.; Mazziotta, John C.

    1985-01-01

    Describes the method, present status, and application of positron emission tomography (PET), an analytical imaging technique for "in vivo" measurements of the anatomical distribution and rates of specific biochemical reactions. Measurements and image dynamic biochemistry link basic and clinical neurosciences with clinical findings…

  5. Positron emission tomography: the conceptual idea using a multidisciplinary approach.

    PubMed

    Paans, Anne M J; van Waarde, Aren; Elsinga, Philip H; Willemsen, Antoon T M; Vaalburg, Willem

    2002-07-01

    Positron emission tomography (PET) is a method for quantitatively measuring biochemical and physiological processes in vivo by using radiopharmaceuticals labeled with positron-emitting radionuclides such as 11C, 13N, 15O, and 18F and by measuring the annihilation radiation using a coincidence technique. This technique is also used for measurement of the pharmacokinetics of labeled drugs and measurement of the effects of drugs on metabolism. Deviations from normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained.

  6. Pure hemidystonia with basal ganglion abnormalities on positron emission tomography

    SciTech Connect

    Perlmutter, J.S.; Raichle, M.E.

    1984-03-01

    We present a patient with hemidystonia and an abnormality of the contralateral basal ganglion seen only with positron emission tomography. A 50-year-old sinistral man suffered minor trauma to the right side of his head and neck. Within 20 minutes he developed paroxysmal intermittent dystonic posturing of his right face, forearm, hand, and foot, with weaker contractions of the left foot, lasting several seconds and recurring every few minutes. Neurological findings between spells were normal. The following were also normal: electrolyte, calcium, magnesium, and arterial blood gas levels, and findings of drug screen, cerebrospinal fluid examination, electroencephalography with nasopharyngeal leads, computed tomographic scanning (initially and four weeks later), and cerebral angiography. Positron emission tomographic scanning revealed abnormalities in the left basal ganglion region, including decreased oxygen metabolism, decreased oxygen extraction, increased blood volume, and increased blood flow.

  7. Technology related parameters affecting quantification in positron emission tomography imaging.

    PubMed

    Visvikis, D; Turzo, A; Bizais, Y; Cheze-Le Rest, C

    2004-07-01

    Some of the issues associated with positron emission tomography (PET) technology which still pose challenges for the recovery of quantitative images are discussed. Through these issues reference to what is today considered as the 'gold standard' in quantitative PET imaging is also presented. A brief comparison of 2-D and 3-D PET is given, together with a short discussion of combined PET/CT imaging devices.

  8. Current and future technological trends in positron emission tomography.

    PubMed

    Karp, J S; Freifelder, R

    1992-04-01

    Current trends in positron emission tomography (PET) instrumentation are examined, with an emphasis on providing information suitable to the prospective PET user. Basic principles underlying PET are explained and information on performance measurements, techniques, and quantitation are given in order to allow the user to compare and contrast different types of PET scanners. These scanner designs are described. Specific examples are given and the combination of PET with other modalities is discussed.

  9. Magnetic resonance imaging and positron emission tomography of band heterotopia.

    PubMed

    Miura, K; Watanabe, K; Maeda, N; Matsumoto, A; Kumagai, T; Ito, K; Kato, T

    1993-01-01

    A case of band heterotopia was reported with findings of positron emission tomography (PET). The patient was an 8-year-old girl who had mild mental retardation and intractable partial epilepsy. Her MRI showed another diffuse layer of gray matter underlying the normal-looking cortex and separated from it by an apparently normal layer of white matter. PET scan with [18F]fluorodeoxyglucose revealed that band heterotopia had the same degree of glucose metabolism as that of the overlying cortex.

  10. Positron emission tomography in the evaluation of subdural hematomas

    SciTech Connect

    Ericson, K.; Bergstroem, M.; Eriksson, L.

    1980-12-01

    Fifteen patients with 21 subdural effusions were investigated both with transmission computer assisted tomography (CAT) and positron emission tomography (PET). The tracer in the emission studies was /sup 68/Ga-EDTA. Twelve lesions were visualized both with CAT and PET. Five lesions that were negative or doubtful on CAT were visualized with PET, whereas four lesions negative or doubtful on PET were demonstrated by CAT. The two methods complement each other due to the fact that they are based on different mechanisms: CAT mainly on attenuation of the fluid collection. PET on isotope accumulation, particularly in the hematoma membranes.

  11. Positron emission tomographic imaging of tumors using monoclonal antibodies

    SciTech Connect

    Zalutsky, M.R.

    1990-12-01

    The overall objective for this research project is to develop methods for utilizing Positron Emission Tomography (PET) to increase the clinical potential of radiolabelled monoclonal antibodies (MAbs). By labeling MAbs with positron-emitting nuclides, it should be possible to quantitate the dynamics of their three-dimensional distribution in vivo. Our long term goals are to apply this approach to investigate the following: normal tissue toxicity; radiation dose to the tumor; and early tumor imaging. The research plans of this proposal include the following specific aims: optimize labeling of MAbs with fluorine 18, bromine 76 and bromine 75; label MAb Mel-14 (reactive against human gliomas and melanomas) and its Fab and F(ab{prime}){sub 2} fragments while retaining immunoreactivity; determine the distribution of Mel-14 in athymic mice bearing human gliomas; determine pharmacokinetics of Mel-14 in nonhuman primates. Experiments with another MAb, TP-1, and iodine 124 and 131 are also planned. 8 figs.

  12. Principles and clinical applications of positron emission tomography.

    PubMed

    Gardner, S F; Green, J A; Bednarczyk, E M; Farnett, L; Miraldi, F

    1992-06-01

    The basics of positron emission tomography (PET) are presented, including the physics, instrumentation, and radiopharmaceuticals involved; the clinical and research applications; and the cost. In PET, organic molecules labeled with positron-emitting radionuclides are injected or inhaled, and the high-energy photons produced by annihilation events are detected by paired, integrated crystal detectors. A computer uses the lines of origin of these photons to reconstruct a three-dimensional map of a functioning organ system. The positron-emitting radionuclides most often used are carbon 11, oxygen 15, nitrogen 13, fluorine 18, and rubidium 82. PET imaging centers usually consist of a cyclotron facility, a radiochemistry facility, a PET scanner, and computers for image reconstruction. Radiopharmaceuticals used in PET may be divided into blood flow-imaging agents, metabolic imaging agents, and drug receptor-imaging agents. Although PET is still primarily a research tool, it has shown diagnostic potential in neurology, cardiology, and oncology. It has also shown promise as a tool for pharmacologic assessment, as in studies of the effects of the fluorinated quinolones on cerebral blood flow and glucose metabolism. PET may become important in drug development because it yields specific information relatively noninvasively. A single study carries an average break-even price tag of $1500-$2000; rigorous cost-benefit analyses should be conducted before society is asked to subsidize such costs. Positron emission tomography is a frontier technology for which valuable clinical applications are being discovered. Pharmacists can contribute enormously to PET applications and at the same time establish a unique subspecialty for the profession.

  13. [Methods and clinical applications of positron emission tomography in endocrinology].

    PubMed

    De Landsheere, C; Lamotte, D

    1990-01-01

    Positron emission tomography (PET) allows to detect in coincidence photons issued from annihilation between positrons and electrons nearby situated. Tomographic detection (plane by plane) and tomographic reconstruction will lead to the quantitation of radioactive distribution per voxel, in the organ of interest. Recent tomographs can acquire simultaneously several transaxial slices, with a high sensitivity and a spatial resolution of 3-5 mm. Commonly used positron emitters have a short half-life: 2, 10, 20 and 110 min for 150, 13N, 11C and 18F, respectively. The use of these isotopes requires on line production of radionuclides and synthesis of selected molecules. In endocrinology, PET allows among others to study noninvasively the receptor density of hormone-dependent neoplasms such as breast, uterus, prostate tumors and prolactinomas. These last tumors represent a particular entity because of several combined characteristics: high turnover rate of amino acids, high density of dopaminergic receptors and response to bromocriptine (analogue of dopamine inhibiting the secretion of prolactin) in relation to the level of receptors. Because PET permits to evaluate the density of dopaminergic receptors and the metabolism of amino acids, theoretical response of the prolactinoma to bromocriptine can be predicted, the achieved therapeutic efficacy can be estimated and the long-term follow up of tumor growth can be assessed. This example illustrates the clinical value of PET in endocrinology.

  14. Positron emission tomography for use in microdosing studies.

    PubMed

    Wagner, Claudia Christina; Müller, Markus; Lappin, Graham; Langer, Oliver

    2008-01-01

    Positron emission tomography (PET) imaging using microdoses of radiolabeled drug tracers is gaining increasing acceptance in modern clinical drug development. This approach is unique in that it allows for direct quantitative assessment of drug concentrations in the tissues targeted for treatment, thereby bridging the gap between pharmacokinetics and pharmacodynamics. Current applications of PET in anticancer, anti-infective and central nervous system drug research are reviewed herein. Situated at the interface of preclinical and clinical drug testing, PET microdosing is a powerful and highly innovative tool for pharmaceutical development.

  15. Direct conversion semiconductor detectors in positron emission tomography

    NASA Astrophysics Data System (ADS)

    Cates, Joshua W.; Gu, Yi; Levin, Craig S.

    2015-05-01

    Semiconductor detectors are playing an increasing role in ongoing research to improve image resolution, contrast, and quantitative accuracy in preclinical applications of positron emission tomography (PET). These detectors serve as a medium for direct detection of annihilation photons. Early clinical translation of this technology has shown improvements in image quality and tumor delineation for head and neck cancers, relative to conventional scintillator-based systems. After a brief outline of the basics of PET imaging and the physical detection mechanisms for semiconductor detectors, an overview of ongoing detector development work is presented. The capabilities of semiconductor-based PET systems and the current state of these devices are discussed.

  16. [Positron emission tomography: diagnostic imaging on a molecular level].

    PubMed

    Allemann, K; Wyss, M; Wergin, M; Bley, C Rohrer; Ametamay, S; Bruehlmeier, M; Kaser-Hotz, B

    2004-08-01

    In human medicine positron emission tomography (PET) is a modern diagnostic imaging method. In the present paper we outline the physical principles of PET and give an overview over the main clinic fields where PET is being used, such as neurology, cardiology and oncology. Moreover, we present a current project in veterinary medicine (in collaboration with the Paul Scherrer Institute and the University Hospital Zurich), where a hypoxia tracer is applied to dogs and cats suffering from spontaneous tumors. Finally new developments in the field of PET were discussed.

  17. Positron Emission Tomography (PET) for benign and malignant disease

    PubMed Central

    Visioni, Anthony; Kim, Julian

    2011-01-01

    Synopsis Functional imaging using radiolabeled probes which specifically bind and accumulate in target tissues has improved the sensitivity and specificity of conventional imaging. Positron Emission Tomography using modified glucose probes (FDG-PET) has demonstrated improved diagnostic accuracy in differentiating benign from malignant lesions in the setting of solitary pulmonary nodules. In addition, FDG-PET has become a useful modality in pre-operative staging of patients with lung cancer and is being tested with many other malignancies for its ability to change patient management. This article provides an overview of the current status of FDG-PET and presents the challenges of moving towards routine use. PMID:21184913

  18. Role of positron emission tomography/computed tomography in dementia.

    PubMed

    Hinds, Sidney R; Stocker, Derek J; Bradley, Yong C

    2013-09-01

    This article provides a clinically based review of positron emission tomography (PET) imaging for dementia. Significant advances in nuclear medicine and molecular imaging techniques have improved the understanding of the genetic and molecular processes that define neurodegenerative dementia diseases. Metabolic imaging remains constant in its ability to document neuronal loss and lost function. Amyloid-β radiotracers are useful in documenting amyloid deposition, differentiating origins of dementia and possibly predicting disease progression. These radiotracers may be useful in diagnosis-specific treatment. PET radiotracers have increased sensitivity and specificity to complement clinical presentation and other adjunct testing in the evaluation of dementia.

  19. The McMaster positron emission tomograph: Design and evaluation

    NASA Astrophysics Data System (ADS)

    Nahmias, Claude

    1984-03-01

    The McMaster positron emission tomograph is an instrument designed for the high resolution, cross sectional study of the human brain. The detector head comprises 160 bismuth germanate crystals, each coupled to a 12.7 mm photomultiplier tube, closely packed on a ring, 53.5 cm in diameter. The tomographic slices examined are either 10 or 20 mm thick. The spatial resolution is 8 mm (fwhm) in the stationary mode. The sensitivity is 16 000 cps/μCi/cc for a 10 mm slice. The instrument has been in clinical use for the past 18 months.

  20. Positron emission tomography: physics, instrumentation, and image analysis.

    PubMed

    Porenta, G

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources, PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and user-friendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center.

  1. Neutrino emissivity from electron-positron annihilation in hot matter in a strong magnetic field

    SciTech Connect

    Amsterdamski, P.; Haensel, P. )

    1990-10-15

    The neutrino emissivity due to electron-positron annihilation in a strong magnetic field is computed. A strong magnetic field can significantly increase the neutrino emissivity at {ital T}{similar to}10{sup 9} K.

  2. Photon shielding for a positron emission tomography suite.

    PubMed

    Courtney, J C; Mendez, P; Hidalgo-Salvatierra, O; Bujenovic, S

    2001-08-01

    This paper provides information on the effects of distance and attenuation in lead sheet and gypsum board of the 0.511 MeV photon produced by positron annihilation. Exposure rates are projected external to an adult injected with 185 MBq (5 mCi) of 18F in a fluorodeoxyglucose solution and for the same activity in a small unshielded container. These data have been applied to estimate the shielding requirements for the Positron Emission Tomography (PET) suite operated by the Nuclear Medicine Department of Our Lady of the Lake Regional Medical Center. To assure that exposures are as low as reasonably achievable, lead was added to the walls of the room where the 18F is stored, handled, and injected into the patients. The PET scanner is installed in a room that formerly contained a Computerized Axial Tomography scanner; the existing 1.6 mm of lead sheet was left in place even though it is not required for personnel protection. During the initial phase of operation, a shield test program was conducted to estimate annual exposures to personnel inside and outside the suite. Projection of measured rates over a year of operation demonstrate that whole body doses are well below regulatory limits.

  3. Positron Emission Tomography Application to Drug Development and Research

    NASA Astrophysics Data System (ADS)

    Salvadori, Piero A.

    The research for the identification and development of new drugs represents a very complex process implying long times and massive investments. This process was not able to parallel the rate of discoveries made in the field of genomic and molecular biology and a gap created between demand of new drugs and the ability of pharmaceutical companies to select good candidates. Positron Emission Tomography, among the different Molecular Imaging modalities, could represent a new tool for the early assessment and screening of new drug candidates and, due to its physical performances and the characteristics of positron-labeled tracers, gain the role of "Biomarker" accepted by the Companies and the Regulatory Bodies of Drug Agencies. To fulfil this task PET has to exploit all of its special features such as data absolute quantification and modelling, high spatial resolution and dynamic imaging. Relevant efforts need to be directed to the careful design and validation of experimental protocols with the main goal of achieving consistency in multi- centric trials.

  4. Microdosing studies in humans: the role of positron emission tomography.

    PubMed

    Bauer, Martin; Wagner, Claudia Christina; Langer, Oliver

    2008-01-01

    Positron emission tomography (PET)-microdosing comprises the administration of a carbon-11- or fluorine-18-labelled drug candidate to human subjects in order to describe the drug's concentration-time profile in body tissues targeted for treatment. As PET microdosing involves the administration of only microgram amounts of unlabelled drug, the potential toxicological risk to human subjects is very limited. Consequently, regulatory authorities require reduced preclinical safety testing as compared with conventional phase 1 studies. Microdose studies are gaining increasing importance in clinical drug research as they have the potential to shorten time-lines and cut costs along the critical path of drug development. Current applications of PET in anticancer, anti-infective and CNS system drug research are reviewed.

  5. Studies of the brain cannabinoid system using positron emission tomography

    SciTech Connect

    Gatley, S.J.; Volkow, N.D.

    1995-10-01

    Studies using radiolabeled psychoactive drugs in conjunction with positron emission tomography (PET) have permitted the imaging of binding sites in the human brain. Similar studies of marijuana have been hampered by the unsuitability of radiolabeled THC for PET studies, and the current unavailability of other in vivo imaging agents for cannabinoid receptors. Recent developments in medicinal chemistry suggest that a PET radiotracer for cannabinoid receptors will soon become available. This chapter briefly reviews these developments, together with the results of PET studies of the effects of marijuana and other abused drugs on brain metabolism. It also reviews PET studies of cocaine binding sites, to demonstrate the kind of investigations that will be possible when a cannabinoid receptor PET radioligand becomes available.

  6. Positron Emission Tomography: state of the art and future developments

    NASA Astrophysics Data System (ADS)

    Pizzichemi, M.

    2016-08-01

    Positron emission tomography (PET) plays a fundamental role in medical imaging, with a wide range of applications covering, among the others, oncology, neurology and cardiology. PET has undergone a steady technological evolution since its introduction in mid 20th century, from the development of 3D PET in the late 1980s, to the invention of PET/CT in the 1990s and more recently with the introduction of PET/MR scanners. The current research topics aiming to develop the next generation of PET scanners are summarized in this paper, focusing on the efforts to increase the sensitivity of the detectors, as long as improving their timing, spatial and energy resolutions, with the final goal of reducing the amount of radioactive dose received by the patients and the duration of the exams while improving at the same time the detectability of lesions.

  7. A Review on Segmentation of Positron Emission Tomography Images

    PubMed Central

    Foster, Brent; Bagci, Ulas; Mansoor, Awais; Xu, Ziyue; Mollura, Daniel J.

    2014-01-01

    Positron Emission Tomography (PET), a non-invasive functional imaging method at the molecular level, images the distribution of biologically targeted radiotracers with high sensitivity. PET imaging provides detailed quantitative information about many diseases and is often used to evaluate inflammation, infection, and cancer by detecting emitted photons from a radiotracer localized to abnormal cells. In order to differentiate abnormal tissue from surrounding areas in PET images, image segmentation methods play a vital role; therefore, accurate image segmentation is often necessary for proper disease detection, diagnosis, treatment planning, and follow-ups. In this review paper, we present state-of-the-art PET image segmentation methods, as well as the recent advances in image segmentation techniques. In order to make this manuscript self-contained, we also briefly explain the fundamentals of PET imaging, the challenges of diagnostic PET image analysis, and the effects of these challenges on the segmentation results. PMID:24845019

  8. Wilson's disease studied with FDG and positron emission tomography

    SciTech Connect

    Hawkins, R.A.; Mazziotta, J.C.; Phelps, M.E.

    1987-11-01

    Four patients with Wilson's disease and eight normal controls were studied with 2-deoxy-2-(/sup 18/F)fluoro-D-glucose (FDG) and positron emission tomography (PET). The patients had diffusely reduced glucose metabolism in all brain regions evaluated compared with controls, with the exception of the thalamus. The ratio of the cerebral metabolic rate for glucose in the lenticular nuclei to hemispheres declined from 1.23 (+/- 0.14 SD) in controls to 1.03 (+/- 0.06) (p less than 0.025) in Wilson's disease patients. Compared with Huntington's disease, the PET FDG results in Wilson's disease indicate relatively less focal involvement of the caudate nucleus, more severe focal changes in the lenticular nuclei, and more significant global changes in glucose metabolism.

  9. History and future technical innovation in positron emission tomography.

    PubMed

    Jones, Terry; Townsend, David

    2017-01-01

    Instrumentation for positron emission tomography (PET) imaging has experienced tremendous improvements in performance over the past 60 years since it was first conceived as a medical imaging modality. Spatial resolution has improved by a factor of 10 and sensitivity by a factor of 40 from the early designs in the 1970s to the high-performance scanners of today. Multimodality configurations have emerged that combine PET with computed tomography (CT) and, more recently, with MR. Whole-body scans for clinical purposes can now be acquired in under 10 min on a state-of-the-art PET/CT. This paper will review the history of these technical developments over 40 years and summarize the important clinical research and healthcare applications that have been made possible by these technical advances. Some perspectives for the future of this technology will also be presented that promise to bring about new applications of this imaging modality in clinical research and healthcare.

  10. Positron emission tomography in CNS drug discovery and drug monitoring.

    PubMed

    Piel, Markus; Vernaleken, Ingo; Rösch, Frank

    2014-11-26

    Molecular imaging methods such as positron emission tomography (PET) are increasingly involved in the development of new drugs. Using radioactive tracers as imaging probes, PET allows the determination of the pharmacokinetic and pharmacodynamic properties of a drug candidate, via recording target engagement, the pattern of distribution, and metabolism. Because of the noninvasive nature and quantitative end point obtainable by molecular imaging, it seems inherently suited for the examination of a pharmaceutical's behavior in the brain. Molecular imaging, most especially PET, can therefore be a valuable tool in CNS drug research. In this Perspective, we present the basic principles of PET, the importance of appropriate tracer selection, the impact of improved radiopharmaceutical chemistry in radiotracer development, and the different roles that PET can fulfill in CNS drug research.

  11. Translational neuroimaging: positron emission tomography studies of monoamine oxidase.

    PubMed

    Fowler, Joanna S; Logan, Jean; Volkow, Nora D; Wang, Gene-Jack

    2005-01-01

    Positron emission tomography (PET) using radiotracers with high molecular specificity is an important scientific tool in studies of monoamine oxidase (MAO), an important enzyme in the regulation of the neurotransmitters dopamine, norepinephrine, and serotonin as well as the dietary amine, tyramine. MAO occurs in two different subtypes, MAO A and MAO B, which have different substrate and inhibitor specificity and which are different gene products. The highly variable subtype distribution with different species makes human studies of special value. MAO A and B can be imaged in the human brain and certain peripheral organs using PET and carbon-11 (half-life 20.4 minutes) labeled mechanism-based irreversible inhibitors, clorgyline and L -deprenyl, respectively. In this article we introduce MAO and describe the development of these radiotracers and their translation from preclinical studies to the investigation of variables affecting MAO in the human brain and peripheral organs.

  12. Tau Positron Emission Tomography (PET) Imaging: Past, Present, and Future.

    PubMed

    Ariza, Manuela; Kolb, Hartmuth C; Moechars, Dieder; Rombouts, Frederik; Andrés, José Ignacio

    2015-06-11

    Alzheimer's disease (AD) is a chronic neurodegenerative disorder and the most common cause of dementia among the elderly population. The good correlation of the density and neocortical spread of neurofibrillary tangles (NFTs) with clinical AD disease progression offers an opportunity for the early diagnosis and staging using a noninvasive imaging technique such as positron emission tomography (PET). Thus, PET imaging of NFTs not only holds promise as a diagnostic tool but also may enable the development of disease modifying therapeutics for AD. In this review, we focus on the structural diversity of tau PET tracers, the challenges related to the identification of high affinity and highly selective NFT ligands, and recent progress in the clinical development of tau PET radioligands.

  13. Newer positron emission tomography radiopharmaceuticals for radiotherapy planning: an overview

    PubMed Central

    Mukherjee, Anirban

    2016-01-01

    Positron emission tomography-computed tomography (PET-CT) has changed cancer imaging in the last decade, for better. It can be employed for radiation treatment planning of different cancers with improved accuracy and outcomes as compared to conventional imaging methods. 18F-fluorodeoxyglucose remains the most widely used though relatively non-specific cancer imaging PET tracer. A wide array of newer PET radiopharmaceuticals has been developed for targeted imaging of different cancers. PET-CT with such new PET radiopharmaceuticals has also been used for radiotherapy planning with encouraging results. In the present review we have briefly outlined the role of PET-CT with newer radiopharmaceuticals for radiotherapy planning and briefly reviewed the available literature in this regard. PMID:26904575

  14. Differential diagnosis of depression: relevance of positron emission tomography

    SciTech Connect

    Schwartz, J.M.; Baxter, L.R. Jr.; Mazziotta, J.C.; Gerner, R.H.; Phelps, M.E.

    1987-09-11

    The proper differential diagnosis of depression is important. A large body of research supports the division of depressive illness into bipolar and unipolar subtypes with respect to demographics, genetics, treatment response, and neurochemical mechanisms. Optimal treatment is different for unipolar and bipolar depressions. Treating a patient with bipolar depression as one would a unipolar patient may precipitate a serious manic episode or possibly even permanent rapid cycling disorder. The clinical distinction between these disorders, while sometimes difficult, can often be achieved through an increased diagnostic suspicion concerning a personal or family history of mania. Positron emission tomography and the FDG method, which allow in vivo study of the glucose metabolic rates for discrete cerebral structures, provide new evidence that bipolar and unipolar depression are two different disorders.

  15. FDG positron emission computed tomography in a study of aphasia

    SciTech Connect

    Metter, E.J.; Wasterlain, C.G.; Kuhl, D.E.; Hanson, W.R.; Phelps, M.E.

    1981-08-01

    Positron emission computed tomography (PECT) using 18F-2-fluoro-2-deoxy-D-glucose (FDG) was used to investigate the correlations between clinical status, anatomy (as described by CT), and metabolism in five patients with stable aphasia resulting from ischemic cerebral infarction. Local cerebral metabolic activity was diminished in an area larger than the area of infarction demonstrated by CT. In one patient, FDG PECT revealed a metabolic lesion that probably caused the aphasic syndrome and was not apparent by CT. The data suggest that reliance on CT in delineating the extent of the brain lesion in aphasia or other neuropsychological defects can be misleading; FDG PECT may provide important additional information. Two patients with similar metabolic lesions had very different clinical syndromes, showing that even when currently available methods are combined, major gaps remain in clinicoanatomical correlations in aphasia.

  16. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    SciTech Connect

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. )

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  17. Antiretroviral Tissue Kinetics: In Vivo Imaging Using Positron Emission Tomography▿

    PubMed Central

    Di Mascio, Michele; Srinivasula, Sharat; Bhattacharjee, Abesh; Cheng, Lily; Martiniova, Lucia; Herscovitch, Peter; Lertora, Juan; Kiesewetter, Dale

    2009-01-01

    Our current knowledge on the antiviral efficacy, dosing, and toxicity of available highly active antiretroviral therapy regimens is mostly derived from plasma or blood kinetics of anti-human immunodeficiency virus (anti-HIV) drugs. However, the blood comprises only 2% of the total target cells in the body. Tissue drug levels may differ substantially from corresponding plasma levels, and drug distribution processes may be characterized by high intertissue variability, leading to suboptimal target site concentrations and the potential risk for therapeutic failures. Positron emission tomography has greatly expanded the scope of the pharmacokinetic measurements that can be performed noninvasively in animal models or humans. We have prepared [18F]FPMPA, a fluorine-18-radiolabeled analogue of tenofovir, to study antiretroviral tissue kinetics in vivo noninvasively and tested the imaging probe in rats. The biodistribution of the fluorine-18 analogue closely follows that of nonfluorinated tenofovir. Compared to that in the blood, the levels of penetration of the antiretroviral drug were found to be significantly reduced in the spleen and submandibular lymph nodes (∼2-fold), in the mesenteric lymph nodes and the testes (∼4-fold), and in the brain compartment (∼25-fold). Intersubject variability of the trough drug concentration (measured at 120 min) in certain tissues, like the colon (coefficient of variation, >100%), is not reflected by the intersubject variability in the blood compartment (coefficient of variation, 24%). Positron emission tomography imaging of the fluorine-18 analogue revealed the accumulation of the antiretroviral drug in the cortex of the kidneys, a potential correlate of tenofovir-induced nephrotoxicity observed in HIV-1-infected treated patients. Thus, [18F]FPMPA is a promising radiotracer for evaluation of tenofovir biodistribution under carefully controlled drug administration protocols. PMID:19667288

  18. Modification of loco-regional microenvironment in brain tumors by spinal cord stimulation. Implications for radio-chemotherapy.

    PubMed

    Clavo, B; Robaina, F; Valcarcel, B; Catala, L; Perez, J L; Cabezon, A; Jorge, I J; Fiuza, D; Hernandez, M A; Jover, R; Carreras, J L

    2012-01-01

    The effectiveness of radiotherapy and chemotherapy in high grade gliomas (HGG) depends on tumor micro-environment. We summarize our experience of the influence of spinal cord stimulation (SCS) on this micro-environment. Patients with HGG (n = 26) were assessed pre- and post-SCS, using: (1) Doppler in middle cerebral arteries (MCA) and (2) in common carotid arteries (CCA); (3) tumor blood-flow using single photon emission computed tomography (SPECT); (4) tumor-pO(2) (mmHg) using polarographic probes (eight tumor areas from five patients); and (5) tumor glucose metabolism using (18)F-fluoro-2-deoxyglucose ((18)FDG) positron emission tomography ((18)FDG-PET). Pre-SCS: tumor blood-flow was lower (P < 0.001) than peri-tumor areas and healthy contra-lateral areas. Tumor-pO(2) was lower (P < 0.042) than healthy tissue. Tumor glucose metabolism was higher than peri-tumor areas (P = 0.017) and healthy contra-lateral areas (P = 0.048). Post-SCS: there were increases in: MCA blood-flow (P ≤ 0.002), CCA blood-flow (P ≤ 0.013), tumor blood-flow (P = 0.033), tumor glucose metabolism (P = 0.027) and tumor-pO(2) (P = 0.022). The percentage of hypoxic values decreased (P = 0.007). SCS can modify tumor micro-environment. The potential usefulness of SCS in improving the effectiveness of radio-chemotherapy in HGG needs to be evaluated.

  19. Design Study of Linear Accelerator-Based Positron Re-Emission Microscopy

    NASA Astrophysics Data System (ADS)

    Ogawa, Hiroshi; Kinomura, Atsushi; Oshima, Nagayasu; Suzuki, Ryoichi; O'Rourke, Brian E.

    In order to shorten the acquisition time of positron re-emission microscopy (PRM), a linear accelerator (LINAC)-based PRM system has been studied. The beam focusing system was designed to obtain a high brightness positron beam on the PRM sample. The beam size at the sample was calculated to be 0.8mm (FWHM), and the positron intensity within the field of view of the PRM was more than one order of magnitude higher in comparison with the previous studies.

  20. Magnetosensory function in rats: localization using positron emission tomography.

    PubMed

    Frilot, Clifton; Carrubba, Simona; Marino, Andrew A

    2009-05-01

    The aim of this study was to show that low-strength electromagnetic fields (EMFs) produced evoked potentials in rats and to localize the activated region in the brain. In response to a 2.5-G, 60-Hz stimulus, onset- and offset-evoked potentials were detected (P < 0.05 in each of the 10 animals studied); the evoked potentials had the same magnitude, latency, and nonlinear relationship to the field seen in previous studies on rabbits and human subjects. The neuroanatomical region of activation associated with the electrophysiological effect was identified by positron emission tomography using fluorodeoxyglucose. Paired emission scans (the same animal with and without field treatment) from 10 additional rats were differenced and averaged to produce a t-statistic image using the pooled variance; the t value of each voxel was compared with a calculated critical t value to identify the activated voxels (P < 0.05). A brain volume of 13 mm(3) (15 voxels) located in the posterior, central cerebellum was found to have been activated by exposure to the field. Taken together, the results indicated that magnetosensory evoked potentials in the rats were associated with increased glucose utilization in the cerebellum, thereby supporting earlier evidence that EMF transduction occurred in the brain.

  1. Metabolic Covariant Network in Relation to Nigrostriatal Degeneration in Carbon Monoxide Intoxication-Related Parkinsonism

    PubMed Central

    Chang, Chiung-Chih; Hsu, Jung-Lung; Chang, Wen-Neng; Huang, Shu-Hua; Huang, Chi-Wei; Chang, Ya-Ting; Chen, Nai-Ching; Lui, Chun-Chung; Lee, Chen-Chang; Hsu, Shih-Wei

    2016-01-01

    Presence of parkinsonian features after carbon monoxide (CO) intoxication is well known and the severity was found to relate to the pre-synaptic dopaminergic deficits. There is no systemic study to analyse the functional network involved in CO-related Parkinsonism. Forty-five CO-related parkinsonism patients and 25 aged-matched controls completed the 3D T1-weighted imaging and 18F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET). Voxel-based morphometry (VBM) was performed to assess the structural and functional brain differences between the patients and controls. Spatial covariant networks responsible for distinguishing patients and controls were constructed using independent component analysis. For validation, the pre-synaptic dopaminergic functional network was established by regression model using striatal TRODAT-1 SPECT as the independent variable. The clinical significance of both networks was determined by correlation with the Unified Parkinson's Disease Rating Scale (UPDRS). Compared with controls, the spatial covariant signals of FDG-PET were significantly lower in the medial and lateral frontal, caudate nucleus, dorsomedial prefrontal areas, and temporal-parietal regions while the spatial intensities correlated significantly with UPDRS total scores. The functional network that correlated with striatum pre-synaptic dopaminergic uptakes included the midbrain, thalamus, caudate, lateral frontal cortex, ventral striatum, ventral, or dorsal anterior cingulate cortex. Both networks overlapped considerably and the topographies reflected structural damage pattern. Our study provides evidence that glucose metabolism in CO-parkinsonism patients pertains to an organized covariant pattern in the cortical regions that is spatially coherent with the cortical map of pre-synaptic dopamine deficits. As the fronto-temporal, striatum, and temporal-parietal areas were involved, the unique metabolic covariant network suggests a different pathophysiology in CO

  2. Associations between the standardized uptake value of 18F-FDG PET/CT and demographic, clinical, pathological, radiological factors in lung cancer

    PubMed Central

    Sunnetcioglu, Aysel; Arısoy, Ahmet; Demir, Yusuf; Ekin, Selami; Dogan, Erkan

    2015-01-01

    Objectives: 18F-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is extensively used to diagnose and stage of lung cancer. The aim of the current study was to investigate the correlation of demographic, clinical, pathological and radiological factors with primer tumor FDG Uptake in patients with lung cancer. Materials and methods: This cross-sectional, clinical study was performed on a total of 57 lung cancer patients newly diagnosed that underwent FDG PET/CT. In addition to descriptive variables, histopathological diagnosis, tumor site and size, hemoglobin level, red cell distribution width, neutrophil to lymphocyte ratio were noted for each patient. The correlation of these variables to SUVmax values in FDG PET/CT was investigated. Results: A total of 57 patients (4 women, 53 men) with an average age of 60.8±9.4 (range: 33-89) participated in the study. Histopathological diagnoses were consistent with squamous cell carcinoma (28, 49.1%), adenocarcinoma (15, 26.3%) and small cell cancer (14, 24.6%). The SUVmax of primary tumor was positively correlated with tumor size (P<0.001). The tumor SUVmax of squamous cell carcinoma (SqCC) (17.49±8.37) was higher than that of adenocarcinoma (AC) (12.80±4.77) and small cell carcinoma (SCC) (12.40±5.80) (P=0.038). Conclusion: SUVmax value was significantly higher for squamous cell carcinoma and it SUVmax values in PET scans was found to be positively correlated with tumor size. This study suggests that, tumor size and histologic subtype had influences upon FDG uptake in lung cancer. PMID:26629078

  3. A Novel Method for Direct site-specific Radiolabeling of Peptides Using [18F]FDG

    PubMed Central

    Namavari, Mohammad; Cheng, Zhen; Zhang, Rong; De, Abhijit; Levi, Jelena; Hoerner, Joshua K.; Yaghoubi, Shahriar S.; Syud, Faisal A.; Gambhir, Sanjiv S.

    2009-01-01

    We have used the well-accepted and easily available 2-[18F]Fluoro-2-deoxyglucose ([18F]FDG) positron emission tomography (PET) tracer as a prosthetic group for synthesis of 18F-labeled peptides. We herein report the synthesis of [18F]FDG-RGD (18F labeled linear RGD) and [18F]FDG-cyclo(RGDDYK) (18F labeled cyclic RGD) as examples of the use of [18F]FDG. We have successfully prepared [18F]FDG-RGD and [18F]FDG-cyclo(RGDDYK) in 27.5% and 41% radiochemical yields (decay corrected) respectively. The receptor binding affinity study of FDG-cyclo(RGDDYK) for integrin αvβ3 , using αvβ3 positive U87MG cells confirmed a competitive displacement with 125I-echistatin as a radioligand. The IC50 value for FDG-cyclo(RGDDYK) was determined to be 0.67 ± 0.19µM. High contrast small animal PET images with relatively moderate tumor uptake were observed for [18F]FDG-RGD and [18F]FDG-cyclo(RGDDYK) as PET probes in xenografts models expressing αvβ3 integrin. In conclusion, we have successfully used [18F]FDG as a prosthetic group to prepare 18F]FDG-RGD and [18F]FDG-cyclic[RGDDYK] based on a simple one step radiosynthesis. The one step radiosynthesis methodology consists of chemoselective oxime formation between an aminooxy functionalized peptide and [18F]FDG. The results have implications for radiolabeling of other macromolecules and would lead to a very simple strategy for routine pre-clinical and clinical use. PMID:19226160

  4. Cerebrospinal fluid analysis detects cerebral amyloid-β accumulation earlier than positron emission tomography.

    PubMed

    Palmqvist, Sebastian; Mattsson, Niklas; Hansson, Oskar

    2016-04-01

    Cerebral accumulation of amyloid-β is thought to be the starting mechanism in Alzheimer's disease. Amyloid-β can be detected by analysis of cerebrospinal fluid amyloid-β42 or amyloid positron emission tomography, but it is unknown if any of the methods can identify an abnormal amyloid accumulation prior to the other. Our aim was to determine whether cerebrospinal fluid amyloid-β42 change before amyloid PET during preclinical stages of Alzheimer's disease. We included 437 non-demented subjects from the prospective, longitudinal Alzheimer's Disease Neuroimaging Initiative (ADNI) study. All underwent (18)F-florbetapir positron emission tomography and cerebrospinal fluid amyloid-β42 analysis at baseline and at least one additional positron emission tomography after a mean follow-up of 2.1 years (range 1.1-4.4 years). Group classifications were based on normal and abnormal cerebrospinal fluid and positron emission tomography results at baseline. We found that cases with isolated abnormal cerebrospinal fluid amyloid-β and normal positron emission tomography at baseline accumulated amyloid with a mean rate of 1.2%/year, which was similar to the rate in cases with both abnormal cerebrospinal fluid and positron emission tomography (1.2%/year, P = 0.86). The mean accumulation rate of those with isolated abnormal cerebrospinal fluid was more than three times that of those with both normal cerebrospinal fluid and positron emission tomography (0.35%/year, P = 0.018). The group differences were similar when analysing yearly change in standardized uptake value ratio of florbetapir instead of percentage change. Those with both abnormal cerebrospinal fluid and positron emission tomography deteriorated more in memory and hippocampal volume compared with the other groups (P < 0.001), indicating that they were closer to Alzheimer's disease dementia. The results were replicated after adjustments of different factors and when using different cut-offs for amyloid-β abnormality

  5. Positron emission tomography: a first-hand experience.

    PubMed

    Traylor, J

    2000-01-01

    In July 1999, the University of Kansas Hospital installed a positron emission tomography (PET) scanner and added PET to the imaging technologies it offers patients and physicians. The new service is managed by the nuclear medicine section in the department of radiology. Plans are being implemented now to install a cyclotron in March 2000. Prior to installation of the scanner, a radiation area survey was performed in the space being considered for the PET unit. We also needed to address other critical considerations, including the manufacturer's requirements for construction of the scanner room, special electrical needs, and how the system would connect to our existing information network. It is important to work closely with your chief financial officer and chief operations officer from the beginning of the purchasing process so that these administrators have up-to-date, supportive information about PET and the progress of the installation. We made use of a variety of promotional techniques to market the new service, including broadcast e-mail, an open house for potential referring physicians, postings on the nuclear medicine Web site and communication through the local media. We also worked with the major insurance providers that utilize our hospital to educate them about PET and its benefits. In addition, we trained our own billing staff about procedures that optimize reimbursement for PET. In March 2000, University of Kansas Hospital will install the first cyclotron in the state, enabling us to generate the drugs used for PET scanning and potentially to add targets for research PET radiopharmaceuticals.

  6. Comparison of scintillators for positron emission mammography (PEM) systems

    SciTech Connect

    Raymond Raylman; Stanislaw Majewski; Mark Smith; Randolph Wojcik; Andrew Weisenberger; Brian Kross; Vladimir Popov; Jamal J. Derakhshan

    2003-02-01

    Positron emission mammography (PEM) has promise as an effective method for the detection of breast lesions. Perhaps the most significant design feature of a PEM system is the choice of scintillator material. In this investigation we compared three scintillators for use in PEM: NaI(Tl), gadolinium oxyorthosilicate (GSO), and lutetium-gadolinium oxyorthosilicate (LGSO). The PEM systems consisted of two 30/spl times/30 arrays of pixelated scintillators (3/spl times/3/spl times/10 mm/sup 3/ for GSO and LGSO and 3/spl times/3/spl times/19 mm/sup 3/ for NaI(Tl)) coupled to arrays of square position-sensitive photomultiplier tubes. The Compton scatter fraction, system energy resolution, spatial resolution, spatial resolution uniformity, and detection sensitivity were compared. Compton scatter fractions for the systems were comparable, between 8% and 9%. The NaI(Tl) system produced the best system energy resolution (18.2%), the GSO system had the worst system energy resolution (28.7%).

  7. Imaging pancreatic islet cells by positron emission tomography

    PubMed Central

    Li, Junfeng; Karunananthan, Johann; Pelham, Bradley; Kandeel, Fouad

    2016-01-01

    It was estimated that every year more than 30000 persons in the United States - approximately 80 people per day - are diagnosed with type 1 diabetes (T1D). T1D is caused by autoimmune destruction of the pancreatic islet (β cells) cells. Islet transplantation has become a promising therapy option for T1D patients, while the lack of suitable tools is difficult to directly evaluate of the viability of the grafted islet over time. Positron emission tomography (PET) as an important non-invasive methodology providing high sensitivity and good resolution, is able to accurate detection of the disturbed biochemical processes and physiological abnormality in living organism. The successful PET imaging of islets would be able to localize the specific site where transplanted islets engraft in the liver, and to quantify the level of islets remain alive and functional over time. This information would be vital to establishing and evaluating the efficiency of pancreatic islet transplantation. Many novel imaging agents have been developed to improve the sensitivity and specificity of PET islet imaging. In this article, we summarize the latest developments in carbon-11, fluorine-18, copper-64, and gallium-68 labeled radioligands for the PET imaging of pancreatic islet cells. PMID:27721939

  8. Geoscientific process monitoring with positron emission tomography (GeoPET)

    NASA Astrophysics Data System (ADS)

    Kulenkampff, Johannes; Gründig, Marion; Zakhnini, Abdelhamid; Lippmann-Pipke, Johanna

    2016-08-01

    Transport processes in geomaterials can be observed with input-output experiments, which yield no direct information on the impact of heterogeneities, or they can be assessed by model simulations based on structural imaging using µ-CT. Positron emission tomography (PET) provides an alternative experimental observation method which directly and quantitatively yields the spatio-temporal distribution of tracer concentration. Process observation with PET benefits from its extremely high sensitivity together with a resolution that is acceptable in relation to standard drill core sizes. We strongly recommend applying high-resolution PET scanners in order to achieve a resolution on the order of 1 mm. We discuss the particularities of PET applications in geoscientific experiments (GeoPET), which essentially are due to high material density. Although PET is rather insensitive to matrix effects, mass attenuation and Compton scattering have to be corrected thoroughly in order to derive quantitative values. Examples of process monitoring of advection and diffusion processes with GeoPET illustrate the procedure and the experimental conditions, as well as the benefits and limits of the method.

  9. The economics of creating a positron emission tomography center.

    PubMed

    Lissak, R J

    2000-10-01

    Positron emission tomography (PET) scanning has been a powerful research tool since its inception. Changes in the marketplace that have allowed PET to move into the clinical environment include the commercial availability of appropriate radiopharmaceuticals, reimbursement of procedures by insurance companies, and increasing awareness of physicians of the benefits of PET. Facilities that are interested in clinical PET need to develop a process to purchase equipment with an appropriate business plan. This is necessary to assure financial viability and to convince hospital administrators of the viability. The creation of a successful PET program requires an understanding of all aspects relating to a center. The process begins with reviewing the mission statement of the facility. The next step is to prepare the feasibility study, which includes reviewing the existing marketplace and determining the volume, level of referring physicians' interest, and availability of radiopharmaceuticals. Finally, an appropriate pro forma needs to be constructed to facilitate the final decision concerning the potential financial viability of such an endeavor.

  10. Usefulness of Positron Emission Tomographic Studies for Gliomas

    PubMed Central

    MIYAKE, Keisuke; OGAWA, Daisuke; OKADA, Masaki; HATAKEYAMA, Tetsuhiro; TAMIYA, Takashi

    2016-01-01

    Non-invasive positron emission tomography (PET) enables the measurement of metabolic and molecular processes with high sensitivity. PET plays a significant role in the diagnosis, prognosis, and treatment of brain tumors and predominantly detects brain tumors by detecting their metabolic alterations, including energy metabolism, amino acids, nucleic acids, and hypoxia. Glucose metabolic tracers are related to tumor cell energy and exhibit good sensitivity but poor specificity for malignant tumors. Amino acid metabolic tracers provide a better delineation of tumors and cellular proliferation. Nucleic acid metabolic tracers have a high sensitivity for malignant tumors and cellular proliferation. Hypoxic metabolism tracers are useful for detecting resistance to radiotherapy and chemotherapy. Therefore, PET imaging techniques are useful for detecting biopsy-targeting points, deciding on tumor resection, radiotherapy planning, monitoring therapy, and distinguishing brain tumor recurrence or progression from post-radiotherapy effects. However, it is not possible to use only one PET tracer to make all clinical decisions because each tracer has both advantages and disadvantages. This study focuses on the different kinds of PET tracers and summarizes their recent applications in patients with gliomas. Combinational uses of PET tracers are expected to contribute to differential diagnosis, prognosis, treatment targeting, and monitoring therapy. PMID:27250577

  11. Modularized compact positron emission tomography detector for rapid system development.

    PubMed

    Xi, Daoming; Liu, Xiang; Zeng, Chen; Liu, Wei; Li, Yanzhao; Hua, Yuexuan; Mei, Xiongze; Kim, Heejong; Xiao, Peng; Kao, Chien-Min; Xie, Qingguo

    2017-01-01

    We report the development of a modularized compact positron emission tomography (PET) detector that outputs serial streams of digital samples of PET event pulses via an Ethernet interface using the UDP/IP protocol to enable rapid configuration of a PET system by connecting multiple such detectors via a network switch to a computer. Presently, the detector is [Formula: see text] in extent (excluding I/O connectors) and contains an [Formula: see text] array of [Formula: see text] one-to-one coupled lutetium-yttrium oxyorthosilicate/silicon photomultiplier pixels. It employs cross-wire and stripline readouts to merge the outputs of the 216 detector pixels to 24 channels. Signals at these channels are sampled using a built-in 24-ch, 4-level field programmable gate arrays-only multivoltage threshold digitizer. In the computer, software programs are implemented to analyze the digital samples to extract event information and to perform energy qualification and coincidence filtering. We have developed two such detectors. We show that all their pixels can be accurately discriminated and measure a crystal-level energy resolution of 14.4% to 19.4% and a detector-level coincidence time resolution of 1.67 ns FWHM. Preliminary imaging results suggests that a PET system based on the detectors can achieve an image resolution of [Formula: see text].

  12. FPGA-Based Pulse Parameter Discovery for Positron Emission Tomography.

    PubMed

    Haselman, Michael; Hauck, Scott; Lewellen, Thomas K; Miyaoka, Robert S

    2009-10-24

    Modern Field Programmable Gate Arrays (FPGAs) are capable of performing complex digital signal processing algorithms with clock rates well above 100MHz. This, combined with FPGA's low expense and ease of use make them an ideal technology for a data acquisition system for a positron emission tomography (PET) scanner. The University of Washington is producing a series of high-resolution, small-animal PET scanners that utilize FPGAs as the core of the front-end electronics. For these next generation scanners, functions that are typically performed in dedicated circuits, or offline, are being migrated to the FPGA. This will not only simplify the electronics, but the features of modern FPGAs can be utilizes to add significant signal processing power to produce higher resolution images. In this paper we report how we utilize the reconfigurable property of an FPGA to self-calibrate itself to determine pulse parameters necessary for some of the pulse processing steps. Specifically, we show how the FPGA can generate a reference pulse based on actual pulse data instead of a model. We also report how other properties of the photodetector pulse (baseline, pulse length, average pulse energy and event triggers) can be determined automatically by the FPGA.

  13. Quantitative Cardiac Positron Emission Tomography: The Time Is Coming!

    PubMed Central

    Sciagrà, Roberto

    2012-01-01

    In the last 20 years, the use of positron emission tomography (PET) has grown dramatically because of its oncological applications, and PET facilities are now easily accessible. At the same time, various groups have explored the specific advantages of PET in heart disease and demonstrated the major diagnostic and prognostic role of quantitation in cardiac PET. Nowadays, different approaches for the measurement of myocardial blood flow (MBF) have been developed and implemented in user-friendly programs. There is large evidence that MBF at rest and under stress together with the calculation of coronary flow reserve are able to improve the detection and prognostication of coronary artery disease. Moreover, quantitative PET makes possible to assess the presence of microvascular dysfunction, which is involved in various cardiac diseases, including the early stages of coronary atherosclerosis, hypertrophic and dilated cardiomyopathy, and hypertensive heart disease. Therefore, it is probably time to consider the routine use of quantitative cardiac PET and to work for defining its place in the clinical scenario of modern cardiology. PMID:24278760

  14. Role of positron emission tomography in urological oncology.

    PubMed

    Rioja, Jorge; Rodríguez-Fraile, Macarena; Lima-Favaretto, Ricardo; Rincón-Mayans, Anibal; Peñuelas-Sánchez, Iván; Zudaire-Bergera, Juan Javier; Parra, Raul O

    2010-12-01

    • Positron emission tomography (PET) is a diagnostic tool using radiotracers to show changes in metabolic activities in tissues. We analysed the role of PET and PET/computed tomography (CT) in the diagnosis, staging, and follow-up of urological tumours. • A critical, non-structured review of the literature of the role of PET and PET/CT in urological oncology was conducted. • PET and PET/CT can play a role in the management of urological malignancies. For prostate cancer, the advances in radiotracers seems promising, with novel radiotracers yielding better diagnostic and staging results than 18F-fluorodeoxyglucose (18F-FDG). In kidney cancer, PET and PET/CT allow a proper diagnosis before the pathological examination of the surgical specimen. For testis cancer, PET and PET/CT have been shown to be useful in the management of seminoma tumours. In bladder cancer, these scans allow a better initial diagnosis for invasive cancer, while detecting occult metastases. • PET and its combined modality PET/CT have shown their potential in the diagnosis of urological malignancies. However, further studies are needed to establish the role of PET in the management of these diseases. Future applications of PET may involve fusion techniques such as magnetic resonance imaging with PET.

  15. Markerless motion tracking of awake animals in positron emission tomography.

    PubMed

    Kyme, Andre; Se, Stephen; Meikle, Steven; Angelis, Georgios; Ryder, Will; Popovic, Kata; Yatigammana, Dylan; Fulton, Roger

    2014-11-01

    Noninvasive functional imaging of awake, unrestrained small animals using motion-compensation removes the need for anesthetics and enables an animal's behavioral response to stimuli or administered drugs to be studied concurrently with imaging. While the feasibility of motion-compensated radiotracer imaging of awake rodents using marker-based optical motion tracking has been shown, markerless motion tracking would avoid the risk of marker detachment, streamline the experimental workflow, and potentially provide more accurate pose estimates over a greater range of motion. We have developed a stereoscopic tracking system which relies on native features on the head to estimate motion. Features are detected and matched across multiple camera views to accumulate a database of head landmarks and pose is estimated based on 3D-2D registration of the landmarks to features in each image. Pose estimates of a taxidermal rat head phantom undergoing realistic rat head motion via robot control had a root mean square error of 0.15 and 1.8 mm using markerless and marker-based motion tracking, respectively. Markerless motion tracking also led to an appreciable reduction in motion artifacts in motion-compensated positron emission tomography imaging of a live, unanesthetized rat. The results suggest that further improvements in live subjects are likely if nonrigid features are discriminated robustly and excluded from the pose estimation process.

  16. Variation in Positron Emission Tomography Use After Colon Cancer Resection

    PubMed Central

    Bailey, Christina E.; Hu, Chung-Yuan; You, Y. Nancy; Kaur, Harmeet; Ernst, Randy D.; Chang, George J.

    2015-01-01

    Purpose: Colon cancer surveillance guidelines do not routinely include positron emission tomography (PET) imaging; however, its use after surgical resection has been increasing. We evaluated the secular patterns of PET use after surgical resection of colon cancer among elderly patients and identified factors associated with its increasing use. Patients and Methods: We used the SEER-linked Medicare database (July 2001 through December 2009) to establish a retrospective cohort of patients age ≥ 66 years who had undergone surgical resection for colon cancer. Postoperative PET use was assessed with the test for trends. Patient, tumor, and treatment characteristics were analyzed using univariable and multivariable logistic regression analyses. Results: Of the 39,221 patients with colon cancer, 6,326 (16.1%) had undergone a PET scan within 2 years after surgery. The use rate steadily increased over time. The majority of PET scans had been performed within 2 months after surgery. Among patients who had undergone a PET scan, 3,644 (57.6%) had also undergone preoperative imaging, and 1,977 (54.3%) of these patients had undergone reimaging with PET within 2 months after surgery. Marriage, year of diagnosis, tumor stage, preoperative imaging, postoperative visit to a medical oncologist, and adjuvant chemotherapy were significantly associated with increased PET use. Conclusion: PET use after colon cancer resection is steadily increasing, and further study is needed to understand the clinical value and effectiveness of PET scans and the reasons for this departure from guideline-concordant care. PMID:25852143

  17. Positron emission tomography in patients with clinically diagnosed Alzheimer's disease.

    PubMed Central

    McGeer, P L; Kamo, H; Harrop, R; Li, D K; Tuokko, H; McGeer, E G; Adam, M J; Ammann, W; Beattie, B L; Calne, D B

    1986-01-01

    Fourteen patients who had clinically diagnosed Alzheimer's disease with mild to severe dementia (mean age 69.1 years) were evaluated by calculation of local cerebral metabolic rate for glucose (LCMR-gl) based on uptake of 18F-2-fluoro-2-deoxyglucose (FDG) detected with positron emission tomography (PET). PET scanning showed that the patients had significantly lower LCMR-gl values than 11 age-matched neurologically normal volunteers (mean age 66.3 years). The differences were most marked in the temporal cortex, followed by the frontal, parietal and occipital cortex. In each case the LCMR-gl value was below the lowest control value in at least one cortical area and usually in several; the reduction in LCMR-gl and the number of regions involved in the patients increased with the severity of the dementia. Deficits noted in neuropsychologic testing generally correlated with those predicted from loss of regional cortical metabolism. The patients with Alzheimer's disease were also examined with magnetic resonance imaging, computed tomography or both; the degree of atrophy found showed only a poor correlation with the neuropsychologic deficit. Significant atrophy was also noted in some of the controls. A detailed analysis of LCMR-gl values in selected cerebral regions of various sizes refuted the hypothesis that the reduction in cortical glucose metabolism in Alzheimer's disease is due to the filling by metabolically inert cerebrospinal fluid of space created by tissue atrophy. Images Fig. 2 Fig. 3 Fig. 4 Fig. 7 Fig. 8 Fig. 9 PMID:3512063

  18. Therapy response evaluation with positron emission tomography-computed tomography.

    PubMed

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice.

  19. Characterization of nontransmural myocardial infarction by positron-emission tomography

    SciTech Connect

    Geltman, E.M.; Biello, D.; Welch, M.J.; Ter-Pogossian, M.M.; Roberts, R.; Sobel, B.E.

    1982-04-01

    The present study was performed to determine whether positron emission tomography (PET) performed after i.v. 11C-palmitate permits detection and characterization of nontransmural myocardial infarction. PET was performed after the i.v. injection of 11C-palmitate in 10 normal subjects, 24 patients with initial nontransmural myocardial infarction (defined electrocardiographically), and 22 patients with transmural infarction. Depressed accumulation of 11C-palmitate was detected with sagittal, coronal and transverse reconstructions, and quantified based on 14 contiguous transaxial reconstructions. Defects with homogeneously intense depression of accumulation of tracer were detected in all 22 patients with transmural infarction (100%). Abnormalities of the distribution of 11C-palmitate in the myocardium were detected in 23 patients with nontransmural infarction (96%). Thallium scintigrams were abnormal in only 11 of 18 patients with nontransmural infarction (61%). Tomographically estimated infarct size was greater among patients with transmural infarction (50.4 +/- 7.8 PET-g-Eq/m2 (+/- SEM SEM)) compared with those with nontransmural infarction (19 +/- 4 PET-g-Eq, p less than 0.01). Residual accumulation of 11C-palmitate within regions of infarction was more intensely depressed among patients with transmural compared to nontransmural infarction (33 +/- 1 vs 39 +/- 1% maximal myocardial radioactivity, p less than 0.01). Thus, PET and metabolic imaging with 11C-palmitate is a sensitive means of detecting, quantifying and characterizing nontransmural and transmural myocardial infarction.

  20. Application of silicon photomultipliers to positron emission tomography.

    PubMed

    Roncali, Emilie; Cherry, Simon R

    2011-04-01

    Historically, positron emission tomography (PET) systems have been based on scintillation crystals coupled to photomultipliers tubes (PMTs). However, the limited quantum efficiency, bulkiness, and relatively high cost per unit surface area of PMTs, along with the growth of new applications for PET, offers opportunities for other photodetectors. Among these, small-animal scanners, hybrid PET/MRI systems, and incorporation of time-of-flight information are of particular interest and require low-cost, compact, fast, and magnetic field compatible photodetectors. With high quantum efficiency and compact structure, avalanche photodiodes (APDs) overcome several of the drawbacks of PMTs, but this is offset by degraded signal-to-noise and timing properties. Silicon photomultipliers (SiPMs) offer an alternative solution, combining many of the advantages of PMTs and APDs. They have high gain, excellent timing properties and are insensitive to magnetic fields. At the present time, SiPM technology is rapidly developing and therefore an investigation into optimal design and operating conditions is underway together with detailed characterization of SiPM-based PET detectors. Published data are extremely promising and show good energy and timing resolution, as well as the ability to decode small scintillator arrays. SiPMs clearly have the potential to be the photodetector of choice for some, or even perhaps most, PET systems.

  1. Microfluidics for Positron Emission Tomography (PET) Imaging Probe Development

    PubMed Central

    Wang, Ming-Wei; Lin, Wei-Yu; Liu, Kan; Masterman-Smith, Michael; Shen, Clifton Kwang-Fu

    2012-01-01

    Due to increased needs for Positron Emission Tomography (PET) scanning, high demands for a wide variety of radiolabeled compounds will have to be met by exploiting novel radiochemistry and engineering technologies to improve the production and development of PET probes. The application of microfluidic reactors to perform radiosyntheses is currently attracting a great deal of interest because of their potential to deliver many advantages over conventional labeling systems. Microfluidic-based radiochemistry can lead to the use of smaller quantities of precursors, accelerated reaction rates and easier purification processes with greater yield and higher specific activity of desired probes. Several ‘proof-of-principle’ examples, along with basics of device architecture and operation, and potential limitations of each design are discussed here. Along with the concept of radioisotope distribution from centralized cyclotron facilities to individual imaging centers and laboratories (“decentralized model”), an easy-to-use, standalone, flexible, fully-automated radiochemical microfluidic platform can open up to simpler and more cost-effective procedures for molecular imaging using PET. PMID:20643021

  2. Automated identification of the lung contours in positron emission tomography

    NASA Astrophysics Data System (ADS)

    Nery, F.; Silvestre Silva, J.; Ferreira, N. C.; Caramelo, F. J.; Faustino, R.

    2013-03-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that permits to analyze, in three dimensions, the physiological processes in vivo. One of the areas where PET has demonstrated its advantages is in the staging of lung cancer, where it offers better sensitivity and specificity than other techniques such as CT. On the other hand, accurate segmentation, an important procedure for Computer Aided Diagnostics (CAD) and automated image analysis, is a challenging task given the low spatial resolution and the high noise that are intrinsic characteristics of PET images. This work presents an algorithm for the segmentation of lungs in PET images, to be used in CAD and group analysis in a large patient database. The lung boundaries are automatically extracted from a PET volume through the application of a marker-driven watershed segmentation procedure which is robust to the noise. In order to test the effectiveness of the proposed method, we compared the segmentation results in several slices using our approach with the results obtained from manual delineation. The manual delineation was performed by nuclear medicine physicians that used a software routine that we developed specifically for this task. To quantify the similarity between the contours obtained from the two methods, we used figures of merit based on region and also on contour definitions. Results show that the performance of the algorithm was similar to the performance of human physicians. Additionally, we found that the algorithm-physician agreement is similar (statistically significant) to the inter-physician agreement.

  3. Positron Emission Tomography Detector Development for Plant Biology

    SciTech Connect

    Weisenberger, A G; McKisson, J; Stolin, A; Zorn, C; Howell, C R; Crowell, A S; Reid, C D; Majewski, S; Smith, M F

    2010-01-01

    There are opportunities for the development of new tools to advance plant biology research through the use of radionuclides. Thomas Jefferson National Accelerator Facility, Duke University, West Virginia University and the University of Maryland are collaborating on the development of radionuclide imaging technologies to facilitate plant biology research. Biological research into optimizing plant productivity under various environmental constraints, biofuel and carbon sequestration research are areas that could potentially benefit from new imaging technologies. Using 11CO2 tracers, the investigators at Triangle University Nuclear Laboratory / Duke University Phytotron are currently researching the dynamical responses of plants to environmental changes forecasted from increasing greenhouse trace gases involved in global change. The biological research primary focus is to investigate the impact of elevated atmospheric CO2 and nutrients limitation on carbon and nitrogen dynamics in plants. We report here on preliminary results of 11CO2 plant imaging experiments involving barley plants using Jefferson Lab dual planar positron emission tomography detectors to image 11CO2 in live barley plants. New detector designs will be developed based on the preliminary studies reported here and further planned.

  4. Florbetapir positron emission tomography and cerebrospinal fluid biomarkers

    PubMed Central

    Hake, Ann; Trzepacz, Paula T.; Wang, Shufang; Yu, Peng; Case, Michael; Hochstetler, Helen; Witte, Michael M.; Degenhardt, Elisabeth K.; Dean, Robert A.

    2015-01-01

    Background We evaluated the relationship between florbetapir-F18 positron emission tomography (FBP PET) and cerebrospinal fluid (CSF) biomarkers. Methods Alzheimer’s Disease Neuroimaging Initiative (ADNI)-GO/2 healthy control (HC), mild cognitive impairment (MCI), and Alzheimer’s disease (AD) dementia subjects with clinical measures and CSF collected ±90 days of FBP PET data were analyzed using correlation and logistic regression. Results In HC and MCI subjects, FBP PET anterior and posterior cingulate and composite standard uptake value ratios correlated with CSF amyloid beta (Aβ1-42) and tau/Aβ1-42 ratios. Using logistic regression, Aβ1-42, total tau (t-tau), phosphorylated tau181P (p-tau), and FBP PET composite each differentiated HC versus AD. Aβ1-42 and t-tau distinguished MCI versus AD, without additional contribution by FBP PET. Total tau and p-tau added discriminative power to FBP PET when classifying HC versus AD. Conclusion Based on cross-sectional diagnostic groups, both amyloid and tau measures distinguish healthy from demented subjects. Longitudinal analyses are needed. PMID:25916563

  5. Simultaneous laser speckle imaging and positron emission tomography

    NASA Astrophysics Data System (ADS)

    Gramer, M.; Feuerstein, D.; Backes, H.; Takagaki, M.; Kumagai, T.; Graf, R.

    2013-06-01

    Complex biological systems often require measurements of multiple parameters with high temporal and spatial resolution. Multimodal approaches and the combination of methods are therefore a powerful tool to address such scientific questions. Laser speckle imaging (LSI) is an optical method that monitors dynamic changes in cortical blood flow (CBF) with high temporal resolution. Positron emission tomography (PET) allows for quantitative imaging of physiological processes and is a gold standard method to determine absolute cerebral blood flow. We developed a setup that allows simultaneous measurement with both modalities. Here, we simultaneously measured CBF with PET and LSI in rats and analyzed how the correlation of PET and LSI is modified when (1) different methods are used for the calculation of speckle inverse correlation time (ICT), (2) speckle data is acquired through thinned or craniectomized skull, (3) influence of surface vessels is removed from the speckle data. For the latter, a method for automated vessel segmentation from LSI data was developed. We obtained the best correlation (R² = 0.890, p<0.001) when correcting for surface vessel structures taking into account the contribution of static scatterers while keeping the coherence factor constant. However, using the originally published relation, which allows a 900 times faster computation of blood flow maps, still provided a good correlation (R2 = 0.879, p<0.001). Given the good correlation between LSI and PET we used our data to calibrate the speckle ICT. Thus, LSI provides CBF in absolute units at high temporal resolution.

  6. Fuzzy-rule-based image reconstruction for positron emission tomography

    NASA Astrophysics Data System (ADS)

    Mondal, Partha P.; Rajan, K.

    2005-09-01

    Positron emission tomography (PET) and single-photon emission computed tomography have revolutionized the field of medicine and biology. Penalized iterative algorithms based on maximum a posteriori (MAP) estimation eliminate noisy artifacts by utilizing available prior information in the reconstruction process but often result in a blurring effect. MAP-based algorithms fail to determine the density class in the reconstructed image and hence penalize the pixels irrespective of the density class. Reconstruction with better edge information is often difficult because prior knowledge is not taken into account. The recently introduced median-root-prior (MRP)-based algorithm preserves the edges, but a steplike streaking effect is observed in the reconstructed image, which is undesirable. A fuzzy approach is proposed for modeling the nature of interpixel interaction in order to build an artifact-free edge-preserving reconstruction. The proposed algorithm consists of two elementary steps: (1) edge detection, in which fuzzy-rule-based derivatives are used for the detection of edges in the nearest neighborhood window (which is equivalent to recognizing nearby density classes), and (2) fuzzy smoothing, in which penalization is performed only for those pixels for which no edge is detected in the nearest neighborhood. Both of these operations are carried out iteratively until the image converges. Analysis shows that the proposed fuzzy-rule-based reconstruction algorithm is capable of producing qualitatively better reconstructed images than those reconstructed by MAP and MRP algorithms. The reconstructed images are sharper, with small features being better resolved owing to the nature of the fuzzy potential function.

  7. Positron emission tomography as a diagnostic tool in oncology.

    PubMed

    Schiepers, C; Hoh, C K

    1998-01-01

    Early diagnosis in oncology is important for treatment by surgical intervention, which generally has the highest curative potential. For higher stages of disease involvement, initiation of rapid treatment is indicated to provide the patient with the optimal therapy regimen. Although this may not improve the prognosis, it will maintain the quality of life. Anatomic imaging modalities, such as CT, MR imaging, and US, are clinically important high-resolution imaging techniques that are well suited to reveal structural abnormalities. However, the differentiation of lesions as being benign or malignant is still problematic. Metabolic imaging modalities in nuclear medicine (NM), i.e., single photon emission computed tomography (SPECT) and positron emission tomography (PET), can reveal biochemical parameters of the lesions such as glucose, oxygen, or amino acid metabolism, or measure the receptor density status. These parameters may allow a completely new clinical perspective in the management and understanding of diseases such as cancer. Although PET has been around since the early 1960s, it has only recently emerged as a powerful diagnostic tool in oncology. Society has great difficulty accepting this clinical imaging modality because of its high cost and complexity. Current applications of PET in oncology have been in characterizing lesions, differentiating recurrent disease from treatment effects, staging tumors, evaluating the extent of disease, and therapy monitoring. Here, the role of PET in diagnosis, staging, and restaging of cancer is reviewed and compared with the other tumor imaging modalities. We cover articles published in the past 3 years. We utilize the typical radiology format, in which the contribution in each body area is reviewed (topographic orientation), instead of the more organ-based approach used in internal medicine.

  8. Positron bunching and electrostatic transport system for the production and emission of dense positronium clouds into vacuum

    NASA Astrophysics Data System (ADS)

    Aghion, S.; Amsler, C.; Ariga, A.; Ariga, T.; Belov, A. S.; Bonomi, G.; Bräunig, P.; Bremer, J.; Brusa, R. S.; Cabaret, L.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Chlouba, K.; Cialdi, S.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Dudarev, A.; Ereditato, A.; Evans, C.; Fesel, J.; Fontana, A.; Forslund, O. K.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Gninenko, S.; Guatieri, F.; Haider, S.; Holmestad, H.; Huse, T.; Jernelv, I. L.; Jordan, E.; Kaltenbacher, T.; Kellerbauer, A.; Kimura, M.; Koetting, T.; Krasnicky, D.; Lagomarsino, V.; Lebrun, P.; Lansonneur, P.; Lehner, S.; Liberadzka, J.; Malbrunot, C.; Mariazzi, S.; Marx, L.; Matveev, V.; Mazzotta, Z.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Pistillo, C.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Rienäcker, B.; Røhne, O. M.; Rosenberger, S.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Sorrentino, F.; Spacek, M.; Storey, J.; Strojek, I. M.; Testera, G.; Tietje, I.; Vamosi, S.; Widmann, E.; Yzombard, P.; Zavatarelli, S.; Zmeskal, J.

    2015-11-01

    We describe a system designed to re-bunch positron pulses delivered by an accumulator supplied by a positron source and a Surko-trap. Positron pulses from the accumulator are magnetically guided in a 0.085 T field and are injected into a region free of magnetic fields through a μ -metal field terminator. Here positrons are temporally compressed, electrostatically guided and accelerated towards a porous silicon target for the production and emission of positronium into vacuum. Positrons are focused in a spot of less than 4 mm FWTM in bunches of ∼8 ns FWHM. Emission of positronium into the vacuum is shown by single shot positron annihilation lifetime spectroscopy.

  9. Positron Emission Tomography for the Assessment of Myocardial Viability

    PubMed Central

    2005-01-01

    Executive Summary Objective The objective was to update the 2001 systematic review conducted by the Institute For Clinical Evaluative Sciences (ICES) on the use of positron emission tomography (PET) in assessing myocardial viability. The update consisted of a review and analysis of the research evidence published since the 2001 ICES review to determine the effectiveness and cost-effectiveness of PET in detecting left ventricular (LV) viability and predicting patient outcomes after revascularization in comparison with other noninvasive techniques. Background Left Ventricular Viability Heart failure is a complex syndrome that impairs the contractile ability of the heart to maintain adequate blood circulation, resulting in poor functional capacity and increased risk of morbidity and mortality. It is the leading cause of hospitalization in elderly Canadians. In more than two-thirds of cases, heart failure is secondary to coronary heart disease. It has been shown that dysfunctional myocardium resulting from coronary heart disease (CAD) may recover contractile function (i.e. considered viable). Dysfunctional but viable myocardium may have been stunned by a brief episode of ischemia, followed by restoration of perfusion, and may regain function spontaneously. It is believed that repetitive stunning results in hibernating myocardium that will only regain contractile function upon revascularization. For people with CAD and severe LV dysfunction (left ventricular ejection fraction [LVEF] <35%) refractory to medical therapy, coronary artery bypass and heart transplantation are the only treatment options. The opportunity for a heart transplant is limited by scarcityof donor hearts. Coronary artery bypass in these patients is associated with high perioperative complications; however, there is evidence that revascularization in the presence of dysfunctional but viable myocardium is associated with survival benefits and lower rates of cardiac events. The assessment of left

  10. Positron emission tomography: a financial and operational analysis.

    PubMed

    Conti, P S; Keppler, J S; Halls, J M

    1994-06-01

    Positron emission tomography (PET) is an emerging clinical imaging technique that is facing the challenges of expansion in a period of imminent health care contraction and reform. Although PET began showing utility in clinical medicine in the mid-1980s [1], its proliferation into mainstream medical practice has not matched that of other new imaging technologies such as MR imaging. Many factors have contributed to this, including the changing health care economy, the high cost of PET, the length of time it takes to develop a PET facility, and its inherent complexity. In part because of the proliferation of the use of other technologies and the general explosion of costs, insurance carriers are now holding diagnostic techniques, including PET, to stricter standards of efficacy. New techniques must show improvement in long-term outcome of patients, a difficult task for diagnostic tools. In addition to these issues, PET is an expensive technology that requires highly trained multidisciplinary personnel. Questions have also been raised about the most appropriate mechanism for regulation of PET isotope preparation, leading to speculation about future regulatory requirements. The current pioneers of PET must meet these challenges in order for it to become a routine imaging technique. Because of its clinical value, PET will probably survive despite the challenges. For many reasons, though, not every hospital should necessarily develop PET services. Conversely, many hospitals without this technology should consider acquiring PET. The purpose of this article is to identify the financial, operational, and clinical challenges facing PET centers today, describe potential organizational configurations that may enable PET to survive in an antitechnology environment, and delineate which institutions should consider this new technology.

  11. Nonhuman primate positron emission tomography neuroimaging in drug abuse research.

    PubMed

    Howell, Leonard Lee; Murnane, Kevin Sean

    2011-05-01

    Positron emission tomography (PET) neuroimaging in nonhuman primates has led to significant advances in our current understanding of the neurobiology and treatment of stimulant addiction in humans. PET neuroimaging has defined the in vivo biodistribution and pharmacokinetics of abused drugs and related these findings to the time course of behavioral effects associated with their addictive properties. With novel radiotracers and enhanced resolution, PET neuroimaging techniques have also characterized in vivo drug interactions with specific protein targets in the brain, including neurotransmitter receptors and transporters. In vivo determinations of cerebral blood flow and metabolism have localized brain circuits implicated in the effects of abused drugs and drug-associated stimuli. Moreover, determinations of the predisposing factors to chronic drug use and long-term neurobiological consequences of chronic drug use, such as potential neurotoxicity, have led to novel insights regarding the pathology and treatment of drug addiction. However, similar approaches clearly need to be extended to drug classes other than stimulants. Although dopaminergic systems have been extensively studied, other neurotransmitter systems known to play a critical role in the pharmacological effects of abused drugs have been largely ignored in nonhuman primate PET neuroimaging. Finally, the study of brain activation with PET neuroimaging has been replaced in humans mostly by functional magnetic resonance imaging (fMRI). There has been some success in implementing pharmacological fMRI in awake nonhuman primates. Nevertheless, the unique versatility of PET imaging will continue to complement the systems-level strengths of fMRI, especially in the context of nonhuman primate drug abuse research.

  12. Super-resolution in respiratory synchronized positron emission tomography.

    PubMed

    Wallach, Daphné; Lamare, Frédéric; Kontaxakis, Giorgos; Visvikis, Dimitris

    2012-02-01

    Respiratory motion is a major source of reduced quality in positron emission tomography (PET). In order to minimize its effects, the use of respiratory synchronized acquisitions, leading to gated frames, has been suggested. Such frames, however, are of low signal-to-noise ratio (SNR) as they contain reduced statistics. Super-resolution (SR) techniques make use of the motion in a sequence of images in order to improve their quality. They aim at enhancing a low-resolution image belonging to a sequence of images representing different views of the same scene. In this work, a maximum a posteriori (MAP) super-resolution algorithm has been implemented and applied to respiratory gated PET images for motion compensation. An edge preserving Huber regularization term was used to ensure convergence. Motion fields were recovered using a B-spline based elastic registration algorithm. The performance of the SR algorithm was evaluated through the use of both simulated and clinical datasets by assessing image SNR, as well as the contrast, position and extent of the different lesions. Results were compared to summing the registered synchronized frames on both simulated and clinical datasets. The super-resolution image had higher SNR (by a factor of over 4 on average) and lesion contrast (by a factor of 2) than the single respiratory synchronized frame using the same reconstruction matrix size. In comparison to the motion corrected or the motion free images a similar SNR was obtained, while improvements of up to 20% in the recovered lesion size and contrast were measured. Finally, the recovered lesion locations on the SR images were systematically closer to the true simulated lesion positions. These observations concerning the SNR, lesion contrast and size were confirmed on two clinical datasets included in the study. In conclusion, the use of SR techniques applied to respiratory motion synchronized images lead to motion compensation combined with improved image SNR and contrast

  13. Noninvasive imaging of islet grafts using positron-emission tomography

    NASA Astrophysics Data System (ADS)

    Lu, Yuxin; Dang, Hoa; Middleton, Blake; Zhang, Zesong; Washburn, Lorraine; Stout, David B.; Campbell-Thompson, Martha; Atkinson, Mark A.; Phelps, Michael; Gambhir, Sanjiv Sam; Tian, Jide; Kaufman, Daniel L.

    2006-07-01

    Islet transplantation offers a potential therapy to restore glucose homeostasis in type 1 diabetes patients. However, islet transplantation is not routinely successful because most islet recipients gradually lose graft function. Furthermore, serological markers of islet function are insensitive to islet loss until the latter stages of islet graft rejection. A noninvasive method of monitoring islet grafts would aid in the assessment of islet graft survival and the evaluation of interventions designed to prolong graft survival. Here, we show that recombinant adenovirus can engineer isolated islets to express a positron-emission tomography (PET) reporter gene and that these islets can be repeatedly imaged by using microPET after transplantation into mice. The magnitude of signal from engineered islets implanted into the axillary cavity was directly related to the implanted islet mass. PET signals attenuated over the following weeks because of the transient nature of adenovirus-mediated gene expression. Because the liver is the preferred site for islet implantation in humans, we also tested whether islets could be imaged after transfusion into the mouse liver. Control studies revealed that both intrahepatic islet transplantation and hyperglycemia altered the biodistribution kinetics of the PET probe systemically. Although transplanted islets were dispersed throughout the liver, clear signals from the liver region of mice receiving PET reporter-expressing islets were detectable for several weeks. Viral transduction, PET reporter expression, and repeated microPET imaging had no apparent deleterious effects on islet function after implantation. These studies lay a foundation for noninvasive quantitative assessments of islet graft survival using PET. diabetes | transplantation

  14. The accuracy of positron emission tomography in the detection of posttransplant lymphoproliferative disorder.

    PubMed

    Dierickx, Daan; Tousseyn, Thomas; Requilé, Annelies; Verscuren, Raf; Sagaert, Xavier; Morscio, Julie; Wlodarska, Iwona; Herreman, An; Kuypers, Dirk; Van Cleemput, Johan; Nevens, Frederik; Dupont, Lieven; Uyttebroeck, Anne; Pirenne, Jacques; De Wolf-Peeters, Christiane; Verhoef, Gregor; Brepoels, Lieselot; Gheysens, Olivier

    2013-05-01

    We investigated sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 18F-fluorodeoxyglucose-positron emission tomography in 170 cases with suspected or biopsy-proven posttransplant lymphoproliferative disorder. All solid organ and hematopoietic stem cell transplant recipients who underwent an 18F-fluorodeoxyglucose-positron emission tomography scan between 2003 and 2010 in our center for the indication posttransplant lymphoproliferative disorder, were retrospectively reviewed and results were compared with tissue biopsy whenever possible. One hundred and seventy positron emission tomography scans in 150 patients were eligible for evaluation. In 45 cases, the patient had a biopsy-confirmed posttransplant lymphoproliferative disorder before positron emission tomography scanning and positron emission tomography was performed for staging purposes. In the remaining 125 cases, positron emission tomography was performed to differentiate between posttransplant lymphoproliferative disorder and other diseases. 18F-fluorodeoxyglucose-uptake was quantitatively expressed by calculation of maximum and mean standardized uptake value in the most intense lesion or, in the absence of attenuation corrected positron emission tomography scans, by comparing uptake in target lesion to liver and mediastinal uptake. We found an overall sensitivity of 89%, specificity of 89%, positive predictive value of 91% and negative predictive value of 87% for posttransplant lymphoproliferative disorder detection by 18F-fluorodeoxyglucose-positron emission tomography. In a subanalysis of the 125 scans performed for differentiating posttransplant lymphoproliferative disorder from other diseases, sensitivity, specificity, positive predictive value and negative predictive value were 90%, 89%, 85% and 93%, respectively. 18F-fluorodeoxyglucose-uptake in posttransplant lymphoproliferative disorder was generally high with a median mean and maximum standardized uptake

  15. The accuracy of positron emission tomography in the detection of posttransplant lymphoproliferative disorder

    PubMed Central

    Dierickx, Daan; Tousseyn, Thomas; Requilé, Annelies; Verscuren, Raf; Sagaert, Xavier; Morscio, Julie; Wlodarska, Iwona; Herreman, An; Kuypers, Dirk; Van Cleemput, Johan; Nevens, Frederik; Dupont, Lieven; Uyttebroeck, Anne; Pirenne, Jacques; De Wolf-Peeters, Christiane; Verhoef, Gregor; Brepoels, Lieselot; Gheysens, Olivier

    2013-01-01

    We investigated sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 18F-fluorodeoxyglucose-positron emission tomography in 170 cases with suspected or biopsy-proven posttransplant lymphoproliferative disorder. All solid organ and hematopoietic stem cell transplant recipients who underwent an 18F-fluorodeoxyglucose-positron emission tomography scan between 2003 and 2010 in our center for the indication posttransplant lymphoproliferative disorder, were retrospectively reviewed and results were compared with tissue biopsy whenever possible. One hundred and seventy positron emission tomography scans in 150 patients were eligible for evaluation. In 45 cases, the patient had a biopsy-confirmed posttransplant lymphoproliferative disorder before positron emission tomography scanning and positron emission tomography was performed for staging purposes. In the remaining 125 cases, positron emission tomography was performed to differentiate between posttransplant lymphoproliferative disorder and other diseases. 18F-fluorodeoxyglucose-uptake was quantitatively expressed by calculation of maximum and mean standardized uptake value in the most intense lesion or, in the absence of attenuation corrected positron emission tomography scans, by comparing uptake in target lesion to liver and mediastinal uptake. We found an overall sensitivity of 89%, specificity of 89%, positive predictive value of 91% and negative predictive value of 87% for posttransplant lymphoproliferative disorder detection by 18F-fluorodeoxyglucose-positron emission tomography. In a subanalysis of the 125 scans performed for differentiating posttransplant lymphoproliferative disorder from other diseases, sensitivity, specificity, positive predictive value and negative predictive value were 90%, 89%, 85% and 93%, respectively. 18F-fluorodeoxyglucose-uptake in posttransplant lymphoproliferative disorder was generally high with a median mean and maximum standardized uptake

  16. Positron Emission Tomography Imaging Using Radiolabeled Inorganic Nanomaterials

    PubMed Central

    Sun, Xiaolian; Cai, Weibo; Chen, Xiaoyuan

    2015-01-01

    CONSPECTUS Positron emission tomography (PET) is a radionuclide imaging technology that plays an important role in preclinical and clinical research. With administration of a small amount of radiotracer, PET imaging can provide a noninvasive, highly sensitive, and quantitative readout of its organ/tissue targeting efficiency and pharmacokinetics. Various radiotracers have been designed to target specific molecular events. Compared with antibodies, proteins, peptides, and other biologically relevant molecules, nanoparticles represent a new frontier in molecular imaging probe design, enabling the attachment of different imaging modalities, targeting ligands, and therapeutic payloads in a single vector. We introduce the radiolabeled nanoparticle platforms that we and others have developed. Due to the fundamental differences in the various nanoparticles and radioisotopes, most radiolabeling methods are designed case-by-case. We focus on some general rules about selecting appropriate isotopes for given types of nanoparticles, as well as adjusting the labeling strategies according to specific applications. We classified these radiolabeling methods into four categories: (1) complexation reaction of radiometal ions with chelators via coordination chemistry; (2) direct bombardment of nanoparticles via hadronic projectiles; (3) synthesis of nanoparticles using a mixture of radioactive and nonradioactive precursors; (4) chelator-free postsynthetic radiolabeling. Method 1 is generally applicable to different nanomaterials as long as the surface chemistry is well-designed. However, the addition of chelators brings concerns of possible changes to the physicochemical properties of nanomaterials and detachment of the radiometal. Methods 2 and 3 have improved radiochemical stability. The applications are, however, limited by the possible damage to the nanocomponent caused by the proton beams (method 2) and harsh synthetic conditions (method 3). Method 4 is still in its infancy

  17. Evaluating Positron Emission Tomography Use in Differentiated Thyroid Cancer

    PubMed Central

    Esfandiari, Nazanene H.; Papaleontiou, Maria; Worden, Francis P.; Haymart, Megan R.

    2015-01-01

    Background: Using the Surveillance, Epidemiology, and End Results—Medicare database, a substantial increase was found in the use of positron emission tomography (PET) scans after 2004 in differentiated thyroid cancer (DTC) patients. The reason for the increased utilization of the PET scan was not clear based on available the data. Therefore, the indications for and outcomes of PET scans performed at an academic institution were evaluated. Methods: A retrospective cohort study was performed of DTC patients who underwent surgery at the University of Michigan Health System from 2006 to 2011. After identifying patients who underwent a PET scan, indications, rate of positive PET scans, and impact on management were evaluated. For positive scans, the location of disease was characterized, and presence of disease on other imaging was determined. Results: Of the 585 patients in the cohort, 111 (19%) patients had 200 PET scans performed for evaluation of DTC. Indications for PET scan included: elevated thyroglobulin and negative radioiodine scan in 52 scans (26.0%), thyroglobulin antibodies in 13 scans (6.5%), rising thyroglobulin in 18 scans (9.0%), evaluation of abnormality on other imaging in 22 scans (11.0%), evaluation of extent of disease in 33 scans (16.5%), follow-up of previous scan in 57 scans (28.5%), other indications in two scans (1.0%), and unclear indications in three scans (1.5%). The PET scan was positive in 124 studies (62.0%); positivity was identified in the thyroid bed on 25 scans, cervical or mediastinal lymph nodes on 105 scans, lung on 28 scans, bone on four scans, and other areas on 14 scans. Therapy following PET scan was surgery in 66 cases (33.0%), chemotherapy or radiation in 23 cases (11.5%), observation in 110 cases (55.0%), and palliative care in one case (0.5%). Disease was identifiable on other imaging in 66% of cases. PET scan results changed management in 59 cases (29.5%). Conclusions: In this academic medical center, the PET scan was

  18. Positron emission tomography imaging using radiolabeled inorganic nanomaterials.

    PubMed

    Sun, Xiaolian; Cai, Weibo; Chen, Xiaoyuan

    2015-02-17

    CONSPECTUS: Positron emission tomography (PET) is a radionuclide imaging technology that plays an important role in preclinical and clinical research. With administration of a small amount of radiotracer, PET imaging can provide a noninvasive, highly sensitive, and quantitative readout of its organ/tissue targeting efficiency and pharmacokinetics. Various radiotracers have been designed to target specific molecular events. Compared with antibodies, proteins, peptides, and other biologically relevant molecules, nanoparticles represent a new frontier in molecular imaging probe design, enabling the attachment of different imaging modalities, targeting ligands, and therapeutic payloads in a single vector. We introduce the radiolabeled nanoparticle platforms that we and others have developed. Due to the fundamental differences in the various nanoparticles and radioisotopes, most radiolabeling methods are designed case-by-case. We focus on some general rules about selecting appropriate isotopes for given types of nanoparticles, as well as adjusting the labeling strategies according to specific applications. We classified these radiolabeling methods into four categories: (1) complexation reaction of radiometal ions with chelators via coordination chemistry; (2) direct bombardment of nanoparticles via hadronic projectiles; (3) synthesis of nanoparticles using a mixture of radioactive and nonradioactive precursors; (4) chelator-free postsynthetic radiolabeling. Method 1 is generally applicable to different nanomaterials as long as the surface chemistry is well-designed. However, the addition of chelators brings concerns of possible changes to the physicochemical properties of nanomaterials and detachment of the radiometal. Methods 2 and 3 have improved radiochemical stability. The applications are, however, limited by the possible damage to the nanocomponent caused by the proton beams (method 2) and harsh synthetic conditions (method 3). Method 4 is still in its infancy

  19. Positron emission tomography and single-photon emission computed tomography in substance abuse research.

    PubMed

    Volkow, Nora D; Fowler, Joanna S; Wang, Gene-Jack

    2003-04-01

    Many advances in the conceptualization of addiction as a disease of the brain have come from the application of imaging technologies directly in the human drug abuser. New knowledge has been driven by advances in radiotracer design and chemistry and positron emission tomography (PET) and single-photon emission computed tomography (SPECT) instrumentation and the integration of these scientific tools with the tools of biochemistry, pharmacology, and medicine. This topic cuts across the medical specialties of neurology, psychiatry, oncology, and cardiology because of the high medical, social, and economic toll that drugs of abuse, including the legal drugs, cigarettes and alcohol, take on society. This article highlights recent advances in the use of PET and SPECT imaging to measure the pharmacokinetic and pharmacodynamic effects of drugs of abuse on the human brain.

  20. Positron emission tomography within a magnetic field using photomultiplier tubes and lightguides.

    PubMed

    Christensen, N L; Hammer, B E; Heil, B G; Fetterly, K

    1995-04-01

    The spatial resolution of positron emission tomography (PET) improves when positron annihilation takes place in a strong magnetic field. In a magnetic field, the Lorentz force restricts positron range perpendicular to the field. Since positron annihilation occurs closer to its point of origin, the positron annihilation point spread function decreases. This was verified experimentally by measuring the spread function of positron annihilation from a 500 mm 68Ge bead imbedded in tissue-equivalent wax. At 5 T the spread function full width at half maximum (FWHM) and the full width at tenth maximum (FWTM) decrease by a factor of 1.42 and 2.09, respectively. Two NaI(Tl) scintillation crystals that interface to a pair of photomultiplier tubes (PMTS) through long lightguides detect positron annihilation at zero field and 5.0 T. Photomultiplier tubes, inoperable in strong magnetic fields, are functional if lightguides bring the photons produced by scintillators within the field to a minimal magnetic field. These tests also demonstrate techniques necessary for combining magnetic resonance imaging (MRI) and PET into one scanner.

  1. Novel pulsed particle accelerator for energy dependent positron re-emission experiments.

    PubMed

    Grill, Niklas; Piochacz, Christian; Zimnik, Samantha; Hugenschmidt, Christoph

    2016-05-01

    We report on a novel device for particle acceleration based on elevation of the potential energy of beam pulses. This so-called energy elevator is particularly beneficial if both the particle source and the sample have to be near ground potential due to experimental constraints. We applied this new technique to enable depth dependent measurements of re-emitted positrons using the surface spectrometer at the NEPOMUC positron beam facility. First, a two-stage bunching system is used to generate positron pulses with a repetition rate of 5 MHz and a duration of 1.663(5) ns before their energy is raised to several keV. The whole system was shown to work with an exceptional efficiency of 88%. We demonstrated the usability of our setup by investigating the positron re-emission spectra of Ni and Pd as function of positron implantation energy. For Ni the positron work function could be determined to be ΦNi (+)=-1.4(2)eV. In addition, as predicted by theory, our experimental findings imply a positive positron work function for Pd.

  2. Cerebrospinal fluid analysis detects cerebral amyloid-β accumulation earlier than positron emission tomography

    PubMed Central

    Mattsson, Niklas

    2016-01-01

    See Rabinovici (doi:10.1093/brain/aww025) for a scientific commentary on this article. Cerebral accumulation of amyloid-β is thought to be the starting mechanism in Alzheimer’s disease. Amyloid-β can be detected by analysis of cerebrospinal fluid amyloid-β42 or amyloid positron emission tomography, but it is unknown if any of the methods can identify an abnormal amyloid accumulation prior to the other. Our aim was to determine whether cerebrospinal fluid amyloid-β42 change before amyloid PET during preclinical stages of Alzheimer’s disease. We included 437 non-demented subjects from the prospective, longitudinal Alzheimer’s Disease Neuroimaging Initiative (ADNI) study. All underwent 18F-florbetapir positron emission tomography and cerebrospinal fluid amyloid-β42 analysis at baseline and at least one additional positron emission tomography after a mean follow-up of 2.1 years (range 1.1–4.4 years). Group classifications were based on normal and abnormal cerebrospinal fluid and positron emission tomography results at baseline. We found that cases with isolated abnormal cerebrospinal fluid amyloid-β and normal positron emission tomography at baseline accumulated amyloid with a mean rate of 1.2%/year, which was similar to the rate in cases with both abnormal cerebrospinal fluid and positron emission tomography (1.2%/year, P = 0.86). The mean accumulation rate of those with isolated abnormal cerebrospinal fluid was more than three times that of those with both normal cerebrospinal fluid and positron emission tomography (0.35%/year, P = 0.018). The group differences were similar when analysing yearly change in standardized uptake value ratio of florbetapir instead of percentage change. Those with both abnormal cerebrospinal fluid and positron emission tomography deteriorated more in memory and hippocampal volume compared with the other groups (P < 0.001), indicating that they were closer to Alzheimer’s disease dementia. The results were replicated after

  3. The diagnostic possibilities of positron emission tomography (PET): applications in oral and maxillofacial buccal oncology.

    PubMed

    Carranza-Pelegrina, Daniela; Lomeña-Caballero, Francisco; Soler-Peter, Marina; Berini-Aytés, Leonardo; Gay-Escoda, Cosme

    2005-01-01

    The principles of positron emission tomography (PET), recently introduced as a diagnostic procedure into the health sciences, are described. The principle clinical applications apply to a particular group of specialties: cardiology, neurology, psychiatry, and above all oncology. Positron emission tomography is a non-invasive diagnostic imaging technique with clinical applications. It is an excellent tool for the study of the stage and possible malignancy of tumors of head and neck, the detection of otherwise clinically indeterminate metastases and lymphadenopathies, and likewise for the diagnosis of relapses. The only tracer with any practical clinical application is fluor-desoxyglucosa-F18 (FDG). PET detects the intense accumulation of FDG produced in malignant tumors due to the increased glycolytic rate of the neoplastic cells. With the introduction of hybrid systems that combine computerized tomography or magnetic resonance with positron emission tomography, important advances are being made in the diagnosis and follow-up of oncologic pathology of head and neck.

  4. Distinguishing tumor recurrence from irradiation sequelae with positron emission tomography in patients treated for larynx cancer

    SciTech Connect

    Greven, K.M.; Williams, D.W. III; Keyes, J.W. Jr.; McGuirt, W.F.; Harkness, B.A.; Watson, N.E. Jr.; Raben, M.; Frazier, L.C.; Geisinger, K.R.; Capellari, J.O.

    1994-07-01

    Distinguishing persistent or recurrent tumor from postradiation edema, or soft tissue/cartilage necrosis in patients treated for carcinoma of the larynx can be difficult. Because recurrent tumor is often submucosal, multiple deep biopsies may be necessary before a diagnosis can be established. Positron emission tomography with 18F-2-fluro-2-deoxglucose (FDG) was studied for its ability to aid in this problem. Positron emission tomography (18FDG) scans were performed on 11 patients who were suspected of having persistent or recurrent tumor after radiation treatment for carcinoma of the larynx. Patients underwent thorough history and physical examinations, scans with computerized tomography, and pathologic evaluation when indicated. Standard uptake values were used to quantitate the FDG uptake in the larynx. The time between completion of radiation treatment and positron emission tomography examination ranged from 2 to 26 months with a median of 6 months. Ten patients underwent computed tomography (CT) of the larynx, which revealed edema of the larynx (six patients), glottic mass (four patients), and cervical nodes (one patient). Positron emission tomography scans revealed increased FDG uptake in the larynx in five patients and laryngectomy confirmed the presence of carcinoma in these patients. Five patients had positron emission tomography results consistent with normal tissue changes in the larynx, and one patient had increased FDG uptake in neck nodes. This patient underwent laryngectomy, and no cancer was found in the primary site, but nodes were pathologically positive. One patient had slightly elevated FDG uptake and negative biopsy results. The remaining patients have been followed for 11 to 14 months since their positron emission studies and their examinations have remained stable. In patients without tumor, average standard uptake values of the larynx ranged from 2.4 to 4.7, and in patients with tumor, the range was 4.9 to 10.7. 18 refs., 3 figs., 1 tab.

  5. The 511 keV emission from positron annihilation in the Galaxy

    SciTech Connect

    Prantzos, N.; Boehm, C.; Bykov, A. M.; Diehl, R.; Ferriere, K.; Guessoum, N.; Jean, P.; Knoedlseder, J.; Marcowith, A.; Moskalenko, I. V.; Strong, A.; Weidenspointner, G.

    2011-07-01

    The first {gamma}-ray line originating from outside the Solar System that was ever detected is the 511 keV emission from positron annihilation in the Galaxy. Despite 30 years of intense theoretical and observational investigation, the main sources of positrons have not been identified up to now. Observations in the 1990s with OSSE/CGRO (Oriented Scintillation Spectrometer Experiment on GRO satellite/Compton Gamma Ray Observatory) showed that the emission is strongly concentrated toward the Galactic bulge. In the 2000s, the spectrometer SPI aboard the European Space Agency's (ESA) International Gamma Ray Astrophysics Laboratory (INTEGRAL) allowed scientists to measure that emission across the entire Galaxy, revealing that the bulge-to-disk luminosity ratio is larger than observed at any other wavelength. This mapping prompted a number of novel explanations, including rather ''exotic'' ones (e.g., dark matter annihilation). However, conventional astrophysical sources, such as type Ia supernovae, microquasars, or x-ray binaries, are still plausible candidates for a large fraction of the observed total 511 keV emission of the bulge. A closer study of the subject reveals new layers of complexity, since positrons may propagate far away from their production sites, making it difficult to infer the underlying source distribution from the observed map of 511 keV emission. However, in contrast to the rather well-understood propagation of high-energy (>GeV) particles of Galactic cosmic rays, understanding the propagation of low-energy ({approx}MeV) positrons in the turbulent, magnetized interstellar medium still remains a formidable challenge. The spectral and imaging properties of the observed 511 keV emission are reviewed and candidate positron sources and models of positron propagation in the Galaxy are critically discussed.

  6. In vitro positron emission tomography (PET): use of positron emission tracers in functional imaging in living brain slices.

    PubMed

    Matsumura, K; Bergström, M; Onoe, H; Takechi, H; Westerberg, G; Antoni, G; Bjurling, P; Jacobson, G B; Långström, B; Watanabe, Y

    1995-05-01

    Positron-emitting radionuclides have short half-lives and high radiation energies compared with radioisotopes generally used in biomedical research. We examined the possibility of applying positron emitter-labeled compounds to functional imaging in brain slices kept viable in an oxygenated buffer solution. Brain slices (300 microns thick) containing the striatum were incubated with positron emitter-labeled tracers for 30-45 min. The slices were then rinsed and placed on the bottom of a Plexiglas chamber filled with oxygenated Krebs-Ringer solution. The bottom of the chamber consisted of a thin polypropylene film to allow good penetration of beta+ particles from the brain slices. The chamber was placed on a storage phosphor screen, which has a higher sensitivity and a wider dynamic range than X-ray films. After an exposure period of 15-60 min, the screen was scanned by the analyzer and radioactivity images of brain slices were obtained within 20 min. We succeeded in obtaining quantitative images of (1) [18F]fluorodeoxyglucose uptake, (2) dopamine D2 receptor binding, (3) dopa-decarboxylase activity, and (4) release of [11C]dopamine preloaded as L-[11C]DOPA in the brain slice preparation. These results demonstrate that positron emitter-labeled tracers in combination with storage phosphor screens are useful for functional imaging of living brain slices as a novel neuroscience technique.

  7. Early postischemic hyperperfusion: pathophysiologic insights from positron emission tomography.

    PubMed

    Marchal, G; Young, A R; Baron, J C

    1999-05-01

    Early postischemic hyperperfusion (EPIH) has long been documented in animal stroke models and is the hallmark of efficient recanalization of the occluded artery with subsequent reperfusion of the tissue (although occasionally it may be seen in areas bordering the hypoperfused area during arterial occlusion). In experimental stroke, early reperfusion has been reported to both prevent infarct growth and aggravate edema formation and hemorrhage, depending on the severity and duration of prior ischemia and the efficiency of reperfusion, whereas neuronal damage with or without enlarged infarction also may result from reperfusion (so-called "reperfusion injury"). In humans, focal hyperperfusion in the subacute stage (i.e., more than 48 hours after onset) has been associated with tissue necrosis in most instances, but regarding the acute stage, its occurrence, its relations with tissue metabolism and viability, and its clinical prognostic value were poorly understood before the advent of positron emission tomography (PET), in part because of methodologic issues. By measuring both CBF and metabolism, PET is an ideal imaging modality to study the pathophysiologic mechanism of EPIH. Although only a few PET studies have been performed in the acute stage that have systematically assessed tissue and clinical outcome in relation to EPIH, they have provided important insights. In one study, about one third of the patients with first-ever middle cerebral artery (MCA) territory stroke studied within 5 to 18 hours after symptom onset exhibited EPIH. In most cases, EPIH affected large parts of the cortical MCA territory in a patchy fashion, together with abnormal vasodilation (increased cerebral blood volume), "luxury perfusion" (decreased oxygen extraction fraction), and mildly increased CMRO2, which was interpreted as postischemic rebound of cellular metabolism in structurally preserved tissue. In that study, the spontaneous outcome of the tissue exhibiting EPIH was good, with late

  8. Molecular Imaging of Transporters with Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Antoni, Gunnar; Sörensen, Jens; Hall, Håkan

    Positron emission tomography (PET) visualization of brain components in vivo is a rapidly growing field. Molecular imaging with PET is also increasingly used in drug development, especially for the determination of drug receptor interaction for CNS-active drugs. This gives the opportunity to relate clinical efficacy to per cent receptor occupancy of a drug on a certain targeted receptor and to relate drug pharmacokinetics in plasma to interaction with target protein. In the present review we will focus on the study of transporters, such as the monoamine transporters, the P-glycoprotein (Pgp) transporter, the vesicular monoamine transporter type 2, and the glucose transporter using PET radioligands. Neurotransmitter transporters are presynaptically located and in vivo imaging using PET can therefore be used for the determination of the density of afferent neurons. Several promising PET ligands for the noradrenaline transporter (NET) have been labeled and evaluated in vivo including in man, but a really useful PET ligand for NET still remains to be identified. The most promising tracer to date is (S,S)-[18F]FMeNER-D2. The in vivo visualization of the dopamine transporter (DAT) may give clues in the evaluation of conditions related to dopamine, such as Parkinson's disease and drug abuse. The first PET radioligands based on cocaine were not selective, but more recently several selective tracers such as [11C]PE2I have been characterized and shown to be suitable as PET radioligands. Although there are a large number of serotonin transporter inhibitors used today as SSRIs, it was not until very recently, when [11C]McN5652 was synthesized, that this transporter was studied using PET. New candidates as PET radioligands for the SERT have subsequently been developed and [11C]DASB and [11C]MADAM and their analogues are today the most promising ligands. The existing radioligands for Pgp transporters seem to be suitable tools for the study of both peripheral and central drug

  9. 77 FR 71803 - Guidance on Food and Drug Administration Oversight of Positron Emission Tomography Drug Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-04

    ... HUMAN SERVICES Food and Drug Administration Guidance on Food and Drug Administration Oversight of Positron Emission Tomography Drug Products--Questions and Answers; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing...

  10. 76 FR 60847 - Draft Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... for the Agency's current good manufacturing practice regulations for PET drugs. DATES: Although you... HUMAN SERVICES Food and Drug Administration Draft Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography Drugs; Availability AGENCY: Food and Drug Administration,...

  11. 77 FR 11553 - Draft Guidance on Food and Drug Administration Oversight of Positron Emission Tomography Drug...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-27

    ... good manufacturing practices (CGMP) for PET drugs. The procedures were finalized and an implementation... HUMAN SERVICES Food and Drug Administration Draft Guidance on Food and Drug Administration Oversight of Positron Emission Tomography Drug Products--Questions and Answers; Availability AGENCY: Food and...

  12. A case of eosinophilic esophagitis discovered with positron emission tomography imaging: a case report

    PubMed Central

    2013-01-01

    Introduction Eosinophilic esophagitis was first reported in 1978, and since then it has been increasingly recognized as one of the major etiologies for dysphagia, food impaction, and food regurgitation. To the best of our knowledge, no case of eosinophilic esophagitis (excluding esophageal eosinophilia not responsive to proton pump inhibitor treatment) has previously been demonstrated on the basis of positron emission tomography imaging. Case presentation A 68-year-old Caucasian man presented with dysphagia to solids with recurrent regurgitation and weight loss of 7lb within the preceding 2 months. The patient attributed these symptoms to radiation therapy he had received 1 year earlier for squamous cell cancer of the lung. The patient underwent routine follow-up positron emission tomography imaging, which showed a hypermetabolic lesion in the posterior mediastinum and was increased at the level of the midesophagus. Conclusion To the best of our knowledge, this is the first reported case of eosinophilic esophagitis demonstrated by positron emission tomography imaging and confirmed with endoscopic evaluation and biopsies both after positron emission tomography imaging and a trial of proton pump inhibitor therapy. This could have an impact on the diagnostic evaluation of esophageal eosinophilic inflammation as well as eosinophilic infiltration of other gastrointestinal organs. PMID:23855975

  13. Functional-Lesion Investigation of Developmental Stuttering with Positron Emission Tomography.

    ERIC Educational Resources Information Center

    Ingham, Roger J.; And Others

    1996-01-01

    Analysis of use of positron emission tomographic measurements of resting-state regional cerebral blood flow in 29 men, 10 of whom stuttered, did not support the idea that developmental stuttering is associated with abnormalities of blood flow at rest. Findings did suggest an essentially normal functional brain terrain with a small number of minor…

  14. Asymptomatic Emphysematous Pyelonephritis - Positron Emission Tomography Computerized Tomography Aided Diagnostic and Therapeutic Elucidation

    PubMed Central

    Pathapati, Deepti; Shinkar, Pawan Gulabrao; kumar, Satya Awadhesh; Jha; Dattatreya, Palanki Satya; Chigurupati, Namrata; Chigurupati, Mohana Vamsy; Rao, Vatturi Venkata Satya Prabhakar

    2017-01-01

    The authors report an interesting coincidental unearthing by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) of a potentially serious medical condition of emphysematous pyelonephritis in a case of nasopharyngeal carcinoma. The management by conservative ureteric stenting and antibiotics was done with gratifying clinical outcome. PMID:28242985

  15. 76 FR 6144 - Positron Emission Tomography; Notice of Public Meeting; Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... injection, ammonia N 13 injection, and sodium fluoride F 18 injection used in positron emission tomography... be submitted for FDG F 18 injection, ammonia N 13 injection, and sodium fluoride F 18 injection used..., ammonia N 13 injection, and sodium fluoride F 18 injection. FDA will present information designed...

  16. Attention Performance in Autism and Regional Brain Metabolic Rate Assessed by Positron Emission Tomography. Brief Report.

    ERIC Educational Resources Information Center

    Buchsbaum, M. S.; And Others

    1992-01-01

    This evaluation of seven high functioning adults with autism utilized positron emission tomography on a visual vigilance task. Although the subjects, as a group, did as well as normal controls on the task, there was a lack of normal hemispheric asymmetry in glucose metabolic rate. A heterogeneous etiology for autism is suggested to explain…

  17. Brain tumor imaging with synthesized /sup 18/F-fluorophenylalanine and positron emission tomography

    SciTech Connect

    Mineura, K.; Kowada, M.; Shishido, F.

    1989-06-01

    Two patients with cerebral gliomas were studied with 18F-fluorophenylalanine, newly synthesized by the electrophilic substitution reaction, using positron emission tomography. The tracer accumulated markedly in the tumor lesion and delineated the extent of the lesion. This new tracer will be promising in the diagnosis of gliomas.

  18. The Neural Correlates of Driving Performance Identified Using Positron Emission Tomography

    ERIC Educational Resources Information Center

    Horikawa, E.; Okamura, N.; Tashiro, M.; Sakurada, Y.; Maruyama, M.; Arai, H.; Yamaguchi, K.; Sasaki, H.; Yanai, K.; Itoh, M.

    2005-01-01

    Driving is a complex behavior involving multiple cognitive domains. To identify neural correlates of driving performance, [^1^5O]H"2O positron emission tomography was performed using a simulated driving task. Compared with the resting condition, simulated driving increased regional cerebral blood flow (rCBF) in the cerebellum, occipital, and…

  19. 77 FR 8262 - Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... HUMAN SERVICES Food and Drug Administration Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing the availability of a draft...

  20. Positron Emission Tomography Methods with Potential for Increased Understanding of Mental Retardation and Developmental Disabilities

    ERIC Educational Resources Information Center

    Sundaram, Senthil K.; Chugani, Harry T.; Chugani, Diane C.

    2005-01-01

    Positron emission tomography (PET) is a technique that enables imaging of the distribution of radiolabeled tracers designed to track biochemical and molecular processes in the body after intravenous injection or inhalation. New strategies for the use of radiolabeled tracers hold potential for imaging gene expression in the brain during development…

  1. Positron emission imaging device and method of using the same

    DOEpatents

    Bingham, Philip R.; Mullens, James Allen

    2013-01-15

    An imaging system and method of imaging are disclosed. The imaging system can include an external radiation source producing pairs of substantially simultaneous radiation emissions of a picturization emission and a verification emissions at an emission angle. The imaging system can also include a plurality of picturization sensors and at least one verification sensor for detecting the picturization and verification emissions, respectively. The imaging system also includes an object stage is arranged such that a picturization emission can pass through an object supported on said object stage before being detected by one of said plurality of picturization sensors. A coincidence system and a reconstruction system can also be included. The coincidence can receive information from the picturization and verification sensors and determine whether a detected picturization emission is direct radiation or scattered radiation. The reconstruction system can produce a multi-dimensional representation of an object imaged with the imaging system.

  2. Non-invasive studies of multiphase flow in process equipment. Positron emission particle tracking technique

    NASA Astrophysics Data System (ADS)

    Balakin, B. V.; Adamsen, T. C. H.; Chang, Y.-F.; Kosinski, P.; Hoffmann, A. C.

    2017-01-01

    Positron emission particle tracking (PEPT) is a novel experimental technique for non-invasive inspection of industrial fluid/particle flows. The method is based on the dynamic positioning of a positron-emitting, flowing object (particle) performed through the sensing of annihilation events and subsequent numerical treatment to determine the particle position. The present paper shows an integrated overview of PEPT studies which were carried out using a new PET scanner in the Bergen University Hospital to study multiphase flows in different geometric configurations.

  3. Current status and future needs for standards of radionuclides used in positron emission tomography.

    PubMed

    Zimmerman, B E

    2013-06-01

    Positron Emission Tomography (PET) is being increasingly used as a quantitative technique for detecting disease and monitoring patient progress during treatment. To ensure the validity of the quantitative information derived from the imaging data, it is imperative that all radioactivity measurements that are part of the imaging procedure be traceable to national or international standards. This paper reviews the current status of standards for positron emitting radionuclides (e.g., (18)F, (68)Ge/(68)Ga, and (124)I) and suggests needs for future work.

  4. Three-dimensional imaging of hidden objects using positron emission backscatter

    SciTech Connect

    Lee, Dongwon; Cowee, Misa; Fenimore, Ed; Galassi, Mark; Looker, Quinn; Mcneil, Wendy V; Stonehill, Laura; Wallace, Mark

    2009-01-01

    Positron emission backscatter imaging is a technique for interrogation and three-dimensional (3-D) reconstruction of hidden objects when we only have access to the objects from one side. Using time-of-flight differences in detected direct and backscattered positron-emitted photons, we construct 3-D images of target objects. Recently at Los Alamos National Laboratory, a fully three-dimensional imaging system has been built and the experimental results are discussed in this paper. Quantitative analysis of images reconstructed in both two- and three-dimensions are also presented.

  5. Asymmetric 511 keV Positron Annihilation Line Emission from the Inner Galactic Disk

    NASA Technical Reports Server (NTRS)

    Skinner, Gerry; Weidenspointner, Georg; Jean, Pierre; Knodlseder, Jurgen; Ballmoos, Perer von; Bignami, Giovanni; Diehl, Roland; Strong, Andrew; Cordier, Bertrand; Schanne, Stephane; Winkler, Christoph

    2008-01-01

    A recently reported asymmetry in the 511 keV gamma-ray line emission from the inner galactic disk is unexpected and mimics an equally unexpected one in the distribution of LMXBs seen at hard X-ray energies. A possible conclusion is that LMXBs are an important source of the positrons whose annihilation gives rise to the line. We will discuss these results, their statistical significance and that of any link between the two. The implication of any association between LMXBs and positrons for the strong annihilation radiation from the galactic bulge will be reviewed.

  6. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

    PubMed

    Vaquero, Juan José; Kinahan, Paul

    2015-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.

  7. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems

    PubMed Central

    Vaquero, Juan José; Kinahan, Paul

    2017-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges. PMID:26643024

  8. Radiopharmaceutical chemistry with iodine-124: a non-standard radiohalogen for positron emission tomography.

    PubMed

    Chacko, Ann-Marie; Divgi, Chaitanya R

    2011-09-01

    Positron emission tomography (PET) is a powerful molecular imaging technology with the ability to image and monitor molecular events in vivo and in real time. With the increased application of PET radiopharmaceuticals for imaging physiological and pathological processes in vivo, there is a demand for versatile positron emitters with longer physical and biological half-lives. Traditional PET radionuclides, such as carbon-11 ((11)C) and fluorine-18 ((18)F), have relatively short half-lives (20 min and 110 min, respectively). Among the currently available positron emitters, the non-standard radiohalogen iodine-124 ((124)I) has the longest physical half-life at 4.2 d. This, combined with the well characterized radiochemistry of radioiodine, is contributing to the increasing utility of (124)I in investigating slow and complex pharmacokinetic processes in clinical nuclear medicine and small animal PET imaging studies. This review will summarize the progress to date on the potential of (124)I as a positron emitting nuclide for molecular imaging purposes, beginning with the production of (124)I. Particular emphasis will be placed on the basic radiochemistry as it applies to the production of various (124)I-labeled compounds, from small molecules, to biomolecules such as peptides and proteins, and finally to macromolecules like nanoparticles. The review will conclude by highlighting promising future directions in using (124)I as a positron emitter in PET radiochemistry and molecular imaging.

  9. Flourodeoxyglucose positron emission tomography scan may be helpful in the case of ductal variant prostate cancer when prostate specific membrane antigen ligand positron emission tomography scan is negative.

    PubMed

    McEwan, Louise M; Wong, David; Yaxley, John

    2017-03-28

    Gallium-68 prostate specific membrane antigen ligand (Ga-68 PSMA) positron emission tomography/computed tomography (PET/CT) scanning is emerging as a useful imaging modality for the staging of suspected and known recurrent or metastatic prostate cancer and in staging of newly diagnosed higher grade prostate cancer. However, we have observed at our institution that in some cases of the more aggressive ductal variant, Ga-68 PSMA uptake has sometimes been poor compared with prominent 18-flourodeoxyglucose (F-18 FDG) avidity seen in F-18 FDG PET/CT, which would suggest that FDG PET/CT scans are important in staging of ductal pattern prostate cancer.

  10. [Positron-emission tomography (PET)--basic considerations].

    PubMed

    von Schulthess, G K; Westera, G; Schubiger, P A

    1993-08-24

    A PET installation is a technically complex system composed essentially of two parts. The first consists in isotope production and synthesis of labeled biochemical compounds, the second in measuring the distribution of radioactivity in the body with the PET camera and the generation of image data. The specific advantage of PET lies on one hand in the use of positron emitters that are isotopes of ubiquitous elements in biologic matter, i.e. exact analogs of biomolecules can be produced and utilized and on the other hand quantification is possible. (= enable quantitative...?) Theoretically there are no limits for the synthesis of radioactive compounds and the method therefore provides unlimited test designs. The short half-life of the employed isotopes is advantageous for radioprotection reasons but the production of labeled compounds necessitates a cyclotron accelerator and a special laboratory for the handling of radioactive compounds rendering the production of the test substances relatively expensive. Measurements take place in a PET camera with a large number of coincidence detectors. The best available cameras have a spatial resolution of 5 mm in all three axes with an axial window of about 15 cm diameter. Evaluation of PET images is done in a qualitative way by superposition on anatomic images (CT, MRI) by image fusion. Quantitative determinations require elaborate computer modeling.

  11. Positron emission tomography detects tissue metabolic activity in myocardial segments with persistent thallium perfusion defects

    SciTech Connect

    Brunken, R.; Schwaiger, M.; Grover-McKay, M.; Phelps, M.E.; Tillisch, J.; Schelbert, H.R.

    1987-09-01

    Positron emission tomography with /sup 13/N-ammonia and /sup 18/F-2-deoxyglucose was used to assess myocardial perfusion and glucose utilization in 51 myocardial segments with a stress thallium defect in 12 patients. Myocardial infarction was defined by a concordant reduction in segmental perfusion and glucose utilization, and myocardial ischemia was identified by preservation of glucose utilization in segments with rest hypoperfusion. Of the 51 segments studied, 36 had a fixed thallium defect, 11 had a partially reversible defect and 4 had a completely reversible defect. Only 15 (42%) of the 36 segments with a fixed defect and 4 (36%) of the 11 segments with a partially reversible defect exhibited myocardial infarction on study with positron tomography. In contrast, residual myocardial glucose utilization was identified in the majority of segments with a fixed (58%) or a partially reversible (64%) thallium defect. All of the segments with a completely reversible defect appeared normal on positron tomography. Apparent improvement in the thallium defect on delayed images did not distinguish segments with ischemia from infarction. Thus, positron emission tomography reveals evidence of persistent tissue metabolism in the majority of segments with a fixed or partially resolving stress thallium defect, implying that markers of perfusion alone may underestimate the extent of viable tissue in hypoperfused myocardial segments.

  12. Positron emission tomography scanning is coming to a hospital near you soon!

    PubMed

    Bashir, Humayun; Shabo, Gregory; Nunan, T O

    2008-04-01

    Positron emission tomography (PET) is still generally not available in the UK; however, there are plans to introduce a national service in England from April 2008. Plans are also at an advanced stage in Scotland and Wales. The main uses of PET are in preoperative staging of lung cancer, detection of recurrent colorectal cancer, and management of patients with lymphoma. Although these provide the bulk of the referral base, PET is also of use in specific situations in patients with less common cancers, such as head and neck cancer, gynaecological cancer, and melanoma. In its more common uses, PET has been shown to be cost effective. Positron emission tomography will play an increasing role in the evaluation of response to treatment to enable early separation of patients who are responding well to chemotherapy from those who are not responding and need to be transferred to another therapy.

  13. Persistence of cerebral metabolic abnormalities in chronic schizophrenia as determined by positron emission tomography

    SciTech Connect

    Wolkin, A.; Jaeger, J.; Brodie, J.D.; Wolf, A.P.; Fowler, J.; Rotrosen, J.; Gomez-Mont, F.; Cancro, R.

    1985-05-01

    Local cerebral metabolic rates were determined by positron emission tomography and the deoxyglucose method in a group of 10 chronic schizophrenic subjects before and after somatic treatment and in eight normal subjects. Before treatment, schizophrenic subjects had markedly lower absolute metabolic activity than did normal controls in both frontal and temporal regions and a trend toward relative hyperactivity in the basal ganglia area. After treatment, their metabolic rates approached those seen in normal subjects in nearly all regions except frontal. Persistence of diminished frontal metabolism was manifested as significant relative hypofrontality. These findings suggest specific loci of aberrant cerebral functioning in chronic schizophrenia and the utility of positron emission tomography in characterizing these abnormalities.

  14. Pain and Opiate Receptors: Considerations for the Design of Positron Emission Tomography Studies

    PubMed Central

    Sadzot, B.; Frost, J. J.

    1990-01-01

    Opiate receptors in the brain are the target of endogenous opioids and of exogenous synthetic opiates. These receptors play a major role in the modulation of pain perception. Using the appropriate ligands, positron emission tomography now allows investigators to monitor neuroreceptors in vivo. We have used 11C-diprenorphine and the extremely potent mu opiate receptor agonist, 11C-carfentanil, to image the distribution of opiate receptors in the brain and to quantify their density, their affinity, and their occupancy. Several important aspects of the in vivo opiate receptor labeling with positron emission tomography in relation to the study of pain are considered in this paper. Monitoring receptor occupancy by opiate drugs as a function of pain relief has the potential to reveal better ways to treat pain. PMID:1964768

  15. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    SciTech Connect

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-05-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions.

  16. Existing Pittsburgh Compound-B positron emission tomography thresholds are too high: statistical and pathological evaluation.

    PubMed

    Villeneuve, Sylvia; Rabinovici, Gil D; Cohn-Sheehy, Brendan I; Madison, Cindee; Ayakta, Nagehan; Ghosh, Pia M; La Joie, Renaud; Arthur-Bentil, Samia Kate; Vogel, Jacob W; Marks, Shawn M; Lehmann, Manja; Rosen, Howard J; Reed, Bruce; Olichney, John; Boxer, Adam L; Miller, Bruce L; Borys, Ewa; Jin, Lee-Way; Huang, Eric J; Grinberg, Lea T; DeCarli, Charles; Seeley, William W; Jagust, William

    2015-07-01

    Amyloid-β, a hallmark of Alzheimer's disease, begins accumulating up to two decades before the onset of dementia, and can be detected in vivo applying amyloid-β positron emission tomography tracers such as carbon-11-labelled Pittsburgh compound-B. A variety of thresholds have been applied in the literature to define Pittsburgh compound-B positron emission tomography positivity, but the ability of these thresholds to detect early amyloid-β deposition is unknown, and validation studies comparing Pittsburgh compound-B thresholds to post-mortem amyloid burden are lacking. In this study we first derived thresholds for amyloid positron emission tomography positivity using Pittsburgh compound-B positron emission tomography in 154 cognitively normal older adults with four complementary approaches: (i) reference values from a young control group aged between 20 and 30 years; (ii) a Gaussian mixture model that assigned each subject a probability of being amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B index uptake; (iii) a k-means cluster approach that clustered subjects into amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B uptake in different brain regions (features); and (iv) an iterative voxel-based analysis that further explored the spatial pattern of early amyloid-β positron emission tomography signal. Next, we tested the sensitivity and specificity of the derived thresholds in 50 individuals who underwent Pittsburgh compound-B positron emission tomography during life and brain autopsy (mean time positron emission tomography to autopsy 3.1 ± 1.8 years). Amyloid at autopsy was classified using Consortium to Establish a Registry for Alzheimer's Disease (CERAD) criteria, unadjusted for age. The analytic approaches yielded low thresholds (standard uptake value ratiolow = 1.21, distribution volume ratiolow = 1.08) that represent the earliest detectable Pittsburgh compound-B signal, as well as high thresholds (standard

  17. Progressive degeneration of the right temporal lobe studied with positron emission tomography.

    PubMed Central

    Tyrrell, P J; Warrington, E K; Frackowiak, R S; Rossor, M N

    1990-01-01

    A 79 year old man with a twelve year progressive history of prosopagnosia and recent naming difficulty, in whom other intellectual skills were preserved, is described. Positron emission tomography (PET) revealed an area of right temporal lobe hypometabolism, with an additional area of less severe hypometabolism at the left temporal pole. This may represent an example of progressive focal cortical degeneration similar to that associated with primary progressive dysphasia, but affecting the right temporal lobe. Images PMID:2292695

  18. Investigation of the performance of the General Electric ADVANCE positron emission tomograph in 3D mode

    SciTech Connect

    Lewellen, T.K.; Kohlmyer, S.G.; Miyaoka, R.S.; Kaplan, M.S.; Stearns, C.W.; Schubert, S.F.

    1996-08-01

    Performance measurements of the General Electric ADVANCE Positron Emission Tomograph operating with the septa retracted (3D mode) were made. All reconstructions were performed with the GE ADVANCE 3D package. Performance tests were carried out with: the NEMA phantoms; a 3D Hoffman phantom; a Data Spectrum torso phantom with lung and cardiac inserts; and the Utah 3D evaluation phantom. Data collected included: transaxial and axial resolution, uniformity, recovery coefficients, count rate performance, dead time accuracy, and effect of scatter correction.

  19. Noninvasive measurement of regional myocardial glucose metabolism by positron emission computed tomography. [Dogs

    SciTech Connect

    Schelbert, H.R.; Phelps, M.E.

    1980-06-01

    While the results of regional myocardial glucose metabolism measurements using positron emission computed tomography (/sup 13/N-ammonia) are promising, their utility and value remains to be determined in man. If this technique can be applied to patients with acute myocardial ischemia or infarction it may permit delineation of regional myocardial segments with altered, yet still active metabolism. Further, it may become possible to evaluate the effects of interventions designed to salvage reversibly injured myocardium by this technique.

  20. Bimedial rectus hypermetabolism in convergence spasm as observed on positron emission tomography.

    PubMed

    Jeong, Seong-Hae; Oh, Young-Mi; Kim, Chae-Yong; Kim, Ji Soo

    2008-09-01

    A 52-year-old man developed vertical gaze palsy, convergence spasm, and convergence-retraction nystagmus due to glioblastoma of the right thalamus. 18F-fluorodeoxyglucose positron emission tomography (PET) inadvertently demonstrated markedly increased metabolism in the medial rectus muscles. The hypermetabolism indicates active contraction of these extraocular muscles due to excessive convergence drive attributed to inappropriate activation or disrupted inhibition of convergence neurons by the diencephalic lesion.

  1. Positron emission tomography-computed tomography coregistration for diagnosis and intraoperative localization in recurrent nelson syndrome.

    PubMed

    Hintz, Eric B; Tomlin, Jeffery M; Chengazi, Vaseem; Vates, G Edward

    2013-06-01

    Recurrent pituitary disease presents unique challenges, including in some cases difficulty localizing a tumor radiographically. Here, we present the case of a patient with recurrent Nelson syndrome whose radiographic work-up was complicated by a significant parasellar metallic artifact. Positron emission tomography ultimately localized the lesion, and coregistration with computed tomography allowed for accurate intraoperative navigation. Additionally, we review a range of imaging techniques available in the evaluation of pituitary disease.

  2. Dynamic Positron Emission Tomography [PET] in Man Using Small Bismuth Germanate Crystals

    DOE R&D Accomplishments Database

    Derenzo, S. E.; Budinger, T. F.; Huesman, R. H.; Cahoon, J. L.

    1982-04-01

    Primary considerations for the design of positron emission tomographs for medical studies in humans are the need for high imaging sensitivity, whole organ coverage, good spatial resolution, high maximum data rates, adequate spatial sampling with minimum mechanical motion, shielding against out of plane activity, pulse height discrimination against scattered photons, and timing discrimination against accidental coincidences. We discuss the choice of detectors, sampling motion, shielding, and electronics to meet these objectives.

  3. [Positron emission tomography in neuroscience. An integrative part of clinical diagnostic methods and experimental research].

    PubMed

    Schaller, B

    2005-02-01

    The role of molecular neuroimaging techniques is increasing in the understanding of pathophysiological mechanism of diseases. To date, positron emission tomography is the most powerful tool for the non-invasive study of biochemical and molecular processes in humans and animals in vivo. With the development in radiochemistry and tracer technology, a variety of endogenously expressed and exogenously introduced genes can be analyzed by PET. This opens up the exciting and rapidly field of molecular imaging, aiming at the non-invasive localisation of a biological process of interest in normal and diseased cells in animal models and humans in vivo. Besides its usefulness for basic research positron emission tomography has been proven to be superior to conventional diagnostic methods in several clinical indications. This is illustrated by detection of biological or anatomic changes that cannot be demonstrated by computed tomography or magnetic resonance imaging, as well as even before symptoms are expressed. The present review summarizes the clinical use of positron emission tomography in neuroscience that has helped elucidate the pathophysiology of a number of diseases and has suggested strategies in the treatment of these patients. Special reference is given to the neurovascular, neurodegenerative and neurooncological disease.

  4. Targeted positron emission tomography imaging of CXCR4 expression in patients with acute myeloid leukemia.

    PubMed

    Herhaus, Peter; Habringer, Stefan; Philipp-Abbrederis, Kathrin; Vag, Tibor; Gerngross, Carlos; Schottelius, Margret; Slotta-Huspenina, Julia; Steiger, Katja; Altmann, Torben; Weißer, Tanja; Steidle, Sabine; Schick, Markus; Jacobs, Laura; Slawska, Jolanta; Müller-Thomas, Catharina; Verbeek, Mareike; Subklewe, Marion; Peschel, Christian; Wester, Hans-Jürgen; Schwaiger, Markus; Götze, Katharina; Keller, Ulrich

    2016-08-01

    Acute myeloid leukemia originates from leukemia-initiating cells that reside in the protective bone marrow niche. CXCR4/CXCL12 interaction is crucially involved in recruitment and retention of leukemia-initiating cells within this niche. Various drugs targeting this pathway have entered clinical trials. To evaluate CXCR4 imaging in acute myeloid leukemia, we first tested CXCR4 expression in patient-derived primary blasts. Flow cytometry revealed that high blast counts in patients with acute myeloid leukemia correlate with high CXCR4 expression. The wide range of CXCR4 surface expression in patients was reflected in cell lines of acute myeloid leukemia. Next, we evaluated the CXCR4-specific peptide Pentixafor by positron emission tomography imaging in mice harboring CXCR4 positive and CXCR4 negative leukemia xenografts, and in 10 patients with active disease. [(68)Ga]Pentixafor-positron emission tomography showed specific measurable disease in murine CXCR4 positive xenografts, but not when CXCR4 was knocked out with CRISPR/Cas9 gene editing. Five of 10 patients showed tracer uptake correlating well with leukemia infiltration assessed by magnetic resonance imaging. The mean maximal standard uptake value was significantly higher in visually CXCR4 positive patients compared to CXCR4 negative patients. In summary, in vivo molecular CXCR4 imaging by means of positron emission tomography is feasible in acute myeloid leukemia. These data provide a framework for future diagnostic and theranostic approaches targeting the CXCR4/CXCL12-defined leukemia-initiating cell niche.

  5. Targeted positron emission tomography imaging of CXCR4 expression in patients with acute myeloid leukemia

    PubMed Central

    Herhaus, Peter; Habringer, Stefan; Philipp-Abbrederis, Kathrin; Vag, Tibor; Gerngross, Carlos; Schottelius, Margret; Slotta-Huspenina, Julia; Steiger, Katja; Altmann, Torben; Weißer, Tanja; Steidle, Sabine; Schick, Markus; Jacobs, Laura; Slawska, Jolanta; Müller-Thomas, Catharina; Verbeek, Mareike; Subklewe, Marion; Peschel, Christian; Wester, Hans-Jürgen; Schwaiger, Markus; Götze, Katharina; Keller, Ulrich

    2016-01-01

    Acute myeloid leukemia originates from leukemia-initiating cells that reside in the protective bone marrow niche. CXCR4/CXCL12 interaction is crucially involved in recruitment and retention of leukemia-initiating cells within this niche. Various drugs targeting this pathway have entered clinical trials. To evaluate CXCR4 imaging in acute myeloid leukemia, we first tested CXCR4 expression in patient-derived primary blasts. Flow cytometry revealed that high blast counts in patients with acute myeloid leukemia correlate with high CXCR4 expression. The wide range of CXCR4 surface expression in patients was reflected in cell lines of acute myeloid leukemia. Next, we evaluated the CXCR4-specific peptide Pentixafor by positron emission tomography imaging in mice harboring CXCR4 positive and CXCR4 negative leukemia xenografts, and in 10 patients with active disease. [68Ga]Pentixafor-positron emission tomography showed specific measurable disease in murine CXCR4 positive xenografts, but not when CXCR4 was knocked out with CRISPR/Cas9 gene editing. Five of 10 patients showed tracer uptake correlating well with leukemia infiltration assessed by magnetic resonance imaging. The mean maximal standard uptake value was significantly higher in visually CXCR4 positive patients compared to CXCR4 negative patients. In summary, in vivo molecular CXCR4 imaging by means of positron emission tomography is feasible in acute myeloid leukemia. These data provide a framework for future diagnostic and theranostic approaches targeting the CXCR4/CXCL12-defined leukemia-initiating cell niche. PMID:27175029

  6. Aspects of positron emission tomography radiochemistry as relevant for food chemistry.

    PubMed

    Wuest, F

    2005-12-01

    Positron emission tomography (PET) is a medical imaging technique using compounds labelled with short-lived positron emitting radioisotopes to obtain functional information of physiological, biochemical and pharmacological processes in vivo. The need to understand the potential link between the ingestion of individual dietary agents and the effect of health promotion or health risk requires the exact metabolic characterization of food ingredients in vivo. This exciting but rather new research field of PET would provide new insights and perspectives on food chemistry by assessing quantitative information on pharmocokinetics and pharmacodynamics of food ingredients and dietary agents. To fully exploit PET technology in food chemistry appropriately radiolabelled compounds as relevant for food sciences are needed. The most widely used short-lived positron emitters are (11)C (t(1/2) = 20.4 min) and (18)F (t(1/2) = 109.8 min). Longer-lived radioisotopes are available by using (76)Br (t(1/2) = 16.2 h) and (124)I (t(1/2) = 4.12 d). The present review article tries to discuss some aspects for the radiolabelling of food ingredients and dietary agents either by means of isotopic labelling with (11)C or via prosthetic group labelling approaches using the positron emitting halogens (18)F, (76)Br and (124)I.

  7. High-resolution PET (positron emission tomography) for medical science studies

    SciTech Connect

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.; Jagust, W.J.; Valk, P.E. )

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging. 6 refs., 21 figs.

  8. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    DOE R&D Accomplishments Database

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  9. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    NASA Astrophysics Data System (ADS)

    Sato, K.; Kobayashi, Y.

    2015-05-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  10. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons.

    PubMed

    Sato, K; Kobayashi, Y

    2015-05-01

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  11. Synthesis and characterisation of zirconium complexes for cell tracking with Zr-89 by positron emission tomography.

    PubMed

    Ferris, Trevor J; Charoenphun, Putthiporn; Meszaros, Levente K; Mullen, Gregory E D; Blower, Philip J; Went, Michael J

    2014-10-21

    The increasing availability of the long half-life positron emitter Zr-89 (half life 78.4 h) suggests that it is a strong candidate for cell labelling and hence cell tracking using positron emission tomography. The aim was to produce a range of neutral ZrL4 lipophilic complexes for cell labelling which could be prepared under radiopharmaceutical conditions. This was achieved when the ligand was oxine, tropolone or ethyl maltol. The complexes can be prepared in high yield from zirconium(iv) precursors in hydrochloric or oxalic acid solution. The oxinate and tropolonate complexes were the most amenable to chromatographic characterisation, and HPLC and ITLC protocols have been established to monitor their radiochemical purity. The radiochemical synthesis and quality control of (89)Zr(oxinate)4 is reported as well as preliminary cell labelling data for the oxinate, tropolonate and ethyl maltolate complexes which indicates that (89)Zr(oxinate)4 is the most promising candidate for further evaluation.

  12. Enhancement of molecular sensitivity in positron emission tomography with quantum correlation of γ-ray photons

    SciTech Connect

    Sato, K.; Kobayashi, Y.

    2015-05-15

    Enhancement of molecular sensitivity in positron emission tomography (PET) has long been discussed with respect to imaging instrumentation and algorithms for data treatment. Here, the molecular sensitivity in PET is discussed on the basis of 2-dimensional coincident measurements of 511 keV γ ray photons resultant from two-photon annihilation. Introduction of an additional selection window based on the energy sum and difference of the coincidently measured γ ray photons, without any significant instrumental and algorithmic changes, showed an improvement in the signal-to-noise ratio (SNR) by an order of magnitude. Improvement of performance characteristics in the PET imaging system was demonstrated by an increase in the noise equivalent count rate (NECR) which takes both the SNR and the detection efficiency into consideration. A further improvement of both the SNR and the NECR is expected for the present system in real clinical and in-vivo environments, where much stronger positron sources are employed.

  13. Brain energy metabolism and dopaminergic function in Huntington's disease measured in vivo using positron emission tomography.

    PubMed

    Leenders, K L; Frackowiak, R S; Quinn, N; Marsden, C D

    1986-01-01

    A 48-year-old man with typical Huntington's disease was investigated with computed tomography (CT) and positron emission tomography. Regional cerebral blood flow, oxygen extraction, oxygen and glucose utilisation, L-Dopa uptake, and dopamine (D2) receptor binding were measured using several positron-labelled tracers. CT showed slight atrophy of the head of caudate but no cortical atrophy, although distinct frontal lobe dysfunction was present on psychometric testing. Oxygen and glucose metabolism and cerebral blood flow were decreased in the striata and to a lesser extent in frontal cortex. Cerebral blood flow was in the low normal range throughout the remainder of the brain. A normal metabolic ratio was found in all regions, since the changes in glucose utilisation paralleled those in oxygen consumption. The capacity of the striatum to store dopamine as assessed by L-[18F]-fluorodopa uptake was normal, but dopamine (D2) receptor binding was decreased when compared to normal subjects.

  14. Brain energy metabolism and dopaminergic function in Huntington's disease measured in vivo using positron emission tomography

    SciTech Connect

    Leenders, K.L.; Frackowiak, R.S.; Quinn, N.; Marsden, C.D.

    1986-01-01

    A 48-year-old man with typical Huntington's disease was investigated with computed tomography (CT) and positron emission tomography. Regional cerebral blood flow, oxygen extraction, oxygen and glucose utilization, L-Dopa uptake, and dopamine (D2) receptor binding were measured using several positron-labelled tracers. CT showed slight atrophy of the head of caudate but no cortical atrophy, although distinct frontal lobe dysfunction was present on psychometric testing. Oxygen and glucose metabolism and cerebral blood flow were decreased in the striata and to a lesser extent in frontal cortex. Cerebral blood flow was in the low normal range throughout the remainder of the brain. A normal metabolic ratio was found in all regions, since the changes in glucose utilization paralleled those in oxygen consumption. The capacity of the striatum to store dopamine as assessed by L-( YF)-fluorodopa uptake was normal, but dopamine (D2) receptor binding was decreased when compared to normal subjects.

  15. FEASIBILITY OF POSITRON EMISSION TOMOGRAPHY OF DOSE DISTRIBUTION IN PROTON BEAM CANCER THERAPY.

    SciTech Connect

    BEEBE - WANG,J.J.; DILMANIAN,F.A.; PEGGS,S.G.; SCHLYEER,D.J.; VASKA,P.

    2002-06-03

    Proton therapy is a treatment modality of increasing utility in clinical radiation oncology mostly because its dose distribution conforms more tightly to the target volume than x-ray radiation therapy. One important feature of proton therapy is that it produces a small amount of positron-emitting isotopes along the beam-path through the non-elastic nuclear interaction of protons with target nuclei such as {sup 12}C, {sup 14}N, and {sup 16}O. These radioisotopes, mainly {sup 11}C, {sup 13}N and {sup 15}O, allow imaging the therapy dose distribution using positron emission tomography (PET). The resulting PET images provide a powerful tool for quality assurance of the treatment, especially when treating inhomogeneous organs such as the lungs or the head-and-neck, where the calculation of the dose distribution for treatment planning is more difficult. This paper uses Monte Carlo simulations to predict the yield of positron emitters produced by a 250 MeV proton beam, and to simulate the productions of the image in a clinical PET scanner.

  16. Positron emission tomography (PET) imaging with 18F-based radiotracers

    PubMed Central

    Alauddin, Mian M

    2012-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that is widely used in early detection and treatment follow up of many diseases, including cancer. This modality requires positron-emitting isotope labeled biomolecules, which are synthesized prior to perform imaging studies. Fluorine-18 is one of the several isotopes of fluorine that is routinely used in radiolabeling of biomolecules for PET; because of its positron emitting property and favorable half-life of 109.8 min. The biologically active molecule most commonly used for PET is 2-deoxy-2-18F-fluoro-β-D-glucose (18F-FDG), an analogue of glucose, for early detection of tumors. The concentrations of tracer accumulation (PET image) demonstrate the metabolic activity of tissues in terms of regional glucose metabolism and accumulation. Other tracers are also used in PET to image the tissue concentration. In this review, information on fluorination and radiofluorination reactions, radiofluorinating agents, and radiolabeling of various compounds and their application in PET imaging is presented. PMID:23133802

  17. Positron emission tomographic imaging of tumors using monoclonal antibodies. Progress report, April 15, 1992--October 31, 1992

    SciTech Connect

    Zalutsky, M.R.

    1992-08-01

    This research project is developing methods for utilizing positron emission tomography (PET) to increase the clinical potential of radiolabeled monoclonal antibodies (MAbs). This report describes the development of methods for labeling MAbs and their fragments with positron-emitting halogen nuclides, fluorine-18 and iodine-124. These nulides were selected because of the widespread availability of F-18 and because of our extensive experience in the development of new protein radiohalogenation methods.

  18. Fluorodeoxyglucose positron emission tomography (FDG-PET) for monitoring lymphadenopathy in the autoimmune lymphoproliferative syndrome (ALPS).

    PubMed

    Rao, V Koneti; Carrasquillo, Jorge A; Dale, Janet K; Bacharach, Stephen L; Whatley, Millie; Dugan, Faith; Tretler, Jean; Fleisher, Thomas; Puck, Jennifer M; Wilson, Wyndham; Jaffe, Elaine S; Avila, Nilo; Chen, Clara C; Straus, Stephen E

    2006-02-01

    Autoimmune lymphoproliferative syndrome (ALPS) is associated with mutations that impair the activity of lymphocyte apoptosis proteins, leading to chronic lymphadenopathy, hepatosplenomegaly, autoimmunity, and an increased risk of lymphoma. We investigated the utility of fluorodeoxyglucose positron emission tomography (FDG-PET) in discriminating benign from malignant lymphadenopathy in ALPS. We report that FDG avidity of benign lymph nodes in ALPS can be high and, hence, by itself does not imply presence of lymphoma; but FDG-PET can help guide the decision for selecting which of many enlarged nodes in ALPS patients to biopsy when lymphoma is suspected.

  19. Positron emission tomography and computed tomography assessments of the aging human brain

    SciTech Connect

    de Leon, M.J.; George, A.E.; Ferris, S.H.; Christman, D.R.; Fowler, J.S.; Gentes, C.I.; Brodie, J.; Reisberg, B.; Wolf, A.P.

    1984-02-01

    The relationship between alterations in brain structure and brain function was studied in vivo in both young and elderly human subjects. Computed tomography revealed significant age-related ventricular and cortical sulcal dilatation. The cortical changes were most closely related to age. Positron emission tomography failed to show regional changes in brain glucose metabolic rate. The results suggest that the normal aging brain undergoes structural atrophic changes without incurring regional metabolic changes. Examination of the correlations between the structural and the metabolic measures revealed no significant relationships. These data are discussed with respect to the significant structure-function relationships that have been reported in Alzheimer disease. 27 references, 3 figures, 2 tables.

  20. [Study of regional cerebral glucose metabolism, in man, while awake or asleep, by positron emission tomography].

    PubMed

    Franck, G; Salmon, E; Poirrier, R; Sadzot, B; Franco, G

    1987-03-01

    Measurements of regional cerebral glucose uptake by the 18F-fluorodeoxyglucose technique (18FDG) and positron emission tomography (PET) along with polygraph recordings were made serially during relaxed wakefulness and different stages of nocturnal sleep in two right-handed normal volunteers. During stage III-IV sleep, values declined diffusely in both hemispheric regions (-31%), thalamus (-33%), cerebellum (-33%) and brain stem (-25%). During paradoxical sleep regional values increased diffusely compared with slow wave sleep. Compared to wakefulness, regional metabolic values seemed to increase but the results were more variable from one volunteer to the other. These preliminary data indicate important regional alterations in cerebral metabolism between sleep states.

  1. Evidence for a dopaminergic deficit in sporadic amyotrophic lateral sclerosis on positron emission scanning

    SciTech Connect

    Takahashi, Hirohide; Snow, B.J.; Bhatt, M.H.; Peppard, R.; Eisen, A.; Calne, D.B. )

    1993-10-23

    Although rare, the chronic neurodegenerative disorders amyotrophic lateral sclerosis (ALS) and idiopathic parkinsonism coexist to a greater degree than expected by chance. This suggests that patients with ALS may have subclinical lesions of the nigrostriatal dopaminergic pathway. To study this hypothesis, the authors did positron emission tomography with 6-fluorodopa on 16 patients with sporadic ALS and without extrapyramidal disease, and compared the results with age-matched controls. They found a significant progressive fall in 6-fluorodopa uptake with time since diagnosis, and reduced dopaminergic function in 3 patients with ALS of long duration. This supports the hypothesis that ALS and IP may share pathogenesis, and, perhaps, etiology.

  2. [Principles and applications of positron emission tomography (PET) in cardiology. PET in Mexico: a reality].

    PubMed

    Alexanderson Rosas, Erick; Kerik, Nora E; Unzek Freiman, Samuel; Fermon Schwaycer, Salomón

    2002-01-01

    Positron emission tomography (PET) offers the unique capability of measuring non-invasive by the regional myocardial substrate flow and the biochemical reaction index in millimol per minute per gram of myocardial tissue. PET also allows for the assessment or quantification of regional myocardial blood flow, cardiac metabolism, ventricular function, myocardial viability, as well as autonomous nervous system, research and evaluating of dilated myocardiopathy and of ventricular hypertrophy. PET's success is based on the radioisotopes properties, their very short half-life allows for the administration of large doses.

  3. Revocation of regulation on positron emission tomography drug products--FDA. Final rule; revocation.

    PubMed

    1997-12-19

    The Food and Drug Administration (FDA) is revoking a regulation on positron emission tomography (PET) radiopharmaceutical drug products. The regulation permits FDA to approve requests from manufacturers of PET drugs for exceptions or alternatives to provisions of the current good manufacturing practice (CGMP) regulations. FDA is taking this action in accordance with provisions of the Food and Drug Administration Modernization Act of 1997 (Modernization Act). Elsewhere in this issue of the Federal Register, FDA is publishing a notice revoking two notices concerning certain guidance documents on PET drugs and the guidance documents to which the notices relate.

  4. Florbetapir (18F) for brain amyloid positron emission tomography: highlights on the European marketing approval.

    PubMed

    Cortes-Blanco, Anabel; Prieto-Yerro, Concha; Martinez-Lazaro, Raul; Zamora, Javier; Jiménez-Huete, Adolfo; Haberkamp, Marion; Pohly, Johannes; Enzmann, Harald; Zinserling, Jörg; Strassmann, Valerie; Broich, Karl

    2014-10-01

    Florbetapir (18F) for brain amyloid positron emission tomography (PET) imaging has been recently approved in Europe to estimate β-amyloid neuritic plaque density in the brain when the subject is still alive. Such density is one of the key issues for the definitive diagnosis of Alzheimer's disease (AD) at autopsy. This capability of florbetapir (18F) is regarded as a significant improvement in the diagnostic procedures for adult patients with cognitive impairment who are being evaluated for AD and other causes of cognitive impairment. The current paper highlights the specific characteristics of the European marketing authorization of florbetapir (18F).

  5. Clinical correlates of decreased anteroposterior metabolic gradients in positron emission tomography (PET) of schizophrenic patients

    SciTech Connect

    DeLisi, L.E.; Buchsbaum, M.S.; Holcomb, H.H.; Dowling-Zimmerman, S.; Pickar, D.; Boronow, J.; Morihisa, J.M.; van Kammen, D.P.; Carpenter, W.; Kessler, R.

    1985-01-01

    The finding in schizophrenic patients of a reversal of the normal frontal to posterior pattern of brain metabolic activity with positron emission tomography (PET) is of interest, but its relevance to psychopathology is unknown. Using PET, the authors studied 21 patients with chronic schizophrenia and 21 age- and sex-matched control subjects. Although eight of the 21 patients and only one of the control subjects showed a relatively lower anteroposterior metabolic gradient, no clinical correlates of this finding were noted. In addition, cerebral atrophy, as determined by CAT scan, was not associated with this aberrant metabolic pattern.

  6. Positron emission tracking of individual particles in particle-laden rimming flow

    SciTech Connect

    Denissenko, P. Thomas, P. J.; Guyez, E.; Parker, D. J.; Seville, J. P. K.

    2014-05-15

    The motion of a single tracer particle in particle-laden rimming flows is investigated experimentally by means of Positron Emission Particle Tracking (PEPT). Semi-dilute suspensions, with a volume fraction of 8% of heavy particles are considered. The trajectory of the tracer particle is monitored for several thousand cylinder revolutions and related to the optically recorded drift of the large-scale granular segregation bands developing in the cylinder. Results of the data analysis provide first insights into the relation between behaviour of individual particles and the spatiotemporal dynamics displayed by the macroscopic particle-segregation patterns.

  7. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    DOE R&D Accomplishments Database

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  8. Treatment modification of yttrium-90 radioembolization based on quantitative positron emission tomography/CT imaging.

    PubMed

    Chang, Ted T; Bourgeois, Austin C; Balius, Anastasia M; Pasciak, Alexander S

    2013-03-01

    Treatment activity for yttrium-90 ((90)Y) radioembolization when calculated by using the manufacturer-recommended technique is only partially patient-specific and may result in a subtumoricidal dose in some patients. The authors describe the use of quantitative (90)Y positron emission tomography/computed tomography as a tool to provide patient-specific optimization of treatment activity and evaluate this new method in a patient who previously received traditional (90)Y radioembolization. The modified treatment resulted in a 40-Gy increase in absorbed dose to tumor and complete resolution of disease in the treated area within 3 months.

  9. Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility.

    PubMed

    da Silva, Teógenes A; Guimarães, Margarete C; Meireles, Leonardo S; Teles, Luciana L D; Lacerda, Marco Aurélio S

    2016-11-01

    A new regulatory statement was issued concerning the eye lens radiation protection of persons in planned exposures. A debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to establish the individual monitoring procedure with the EYE-D™ holder and a MCP-N LiF:Mg,Cu,P thermoluminescent chip detector for measuring the personal dose equivalent Hp(3) in workers of a Positron Emission Tomography Radiopharmaceutical Production Facility.

  10. Positron Emission Tomography-Scanner at Children`s Hospital of Michigan at Detroit, Michigan

    SciTech Connect

    Not Available

    1992-12-31

    The Department of Energy has prepared an environmental assessment (EA), DOE/EA-0795, to support the DOE decision to provide a grant of $7,953,600 to be used in support of a proposed Positron Emission Tomography Scanner at Children`s Hospital of Michigan at Detroit, Michigan. Based upon the analysis in the EA, DOE has determined that the proposed action is not a major Federal action significantly affected the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA). Therefore, the preparation of an Environmental Impact Statement is not required and DOE is issuing this Finding of No Significant Impact (FONSI).

  11. Intraprocedural yttrium-90 positron emission tomography/CT for treatment optimization of yttrium-90 radioembolization.

    PubMed

    Bourgeois, Austin C; Chang, Ted T; Bradley, Yong C; Acuff, Shelley N; Pasciak, Alexander S

    2014-02-01

    Radioembolization with yttrium-90 ((90)Y) microspheres relies on delivery of appropriate treatment activity to ensure patient safety and optimize treatment efficacy. We report a case in which (90)Y positron emission tomography (PET)/computed tomography (CT) was performed to optimize treatment planning during a same-day, three-part treatment session. This treatment consisted of (i) an initial (90)Y infusion with a dosage determined using an empiric treatment planning model, (ii) quantitative (90)Y PET/CT imaging, and (iii) a secondary infusion with treatment planning based on quantitative imaging data with the goal of delivering a specific total tumor absorbed dose.

  12. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    SciTech Connect

    Herraiz, J. L.; Sitek, A.

    2015-11-15

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  13. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    PubMed Central

    Herraiz, J. L.; Sitek, A.

    2015-01-01

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data. PMID:26520759

  14. Pixelated CdTe detectors to overcome intrinsic limitations of crystal based positron emission mammographs

    NASA Astrophysics Data System (ADS)

    De Lorenzo, G.; Chmeissani, M.; Uzun, D.; Kolstein, M.; Ozsahin, I.; Mikhaylova, E.; Arce, P.; Cañadas, M.; Ariño, G.; Calderón, Y.

    2013-01-01

    A positron emission mammograph (PEM) is an organ dedicated positron emission tomography (PET) scanner for breast cancer detection. State-of-the-art PEMs employing scintillating crystals as detection medium can provide metabolic images of the breast with significantly higher sensitivity and specificity with respect to standard whole body PET scanners. Over the past few years, crystal PEMs have dramatically increased their importance in the diagnosis and treatment of early stage breast cancer. Nevertheless, designs based on scintillators are characterized by an intrinsic deficiency of the depth of interaction (DOI) information from relatively thick crystals constraining the size of the smallest detectable tumor. This work shows how to overcome such intrinsic limitation by substituting scintillating crystals with pixelated CdTe detectors. The proposed novel design is developed within the Voxel Imaging PET (VIP) Pathfinder project and evaluated via Monte Carlo simulation. The volumetric spatial resolution of the VIP-PEM is expected to be up to 6 times better than standard commercial devices with a point spread function of 1 mm full width at half maximum (FWHM) in all directions. Pixelated CdTe detectors can also provide an energy resolution as low as 1.5% FWHM at 511 keV for a virtually pure signal with negligible contribution from scattered events.

  15. Pixelated CdTe detectors to overcome intrinsic limitations of crystal based positron emission mammographs.

    PubMed

    De Lorenzo, G; Chmeissani, M; Uzun, D; Kolstein, M; Ozsahin, I; Mikhaylova, E; Arce, P; Cañadas, M; Ariño, G; Calderón, Y

    2013-01-01

    A positron emission mammograph (PEM) is an organ dedicated positron emission tomography (PET) scanner for breast cancer detection. State-of-the-art PEMs employing scintillating crystals as detection medium can provide metabolic images of the breast with significantly higher sensitivity and specificity with respect to standard whole body PET scanners. Over the past few years, crystal PEMs have dramatically increased their importance in the diagnosis and treatment of early stage breast cancer. Nevertheless, designs based on scintillators are characterized by an intrinsic deficiency of the depth of interaction (DOI) information from relatively thick crystals constraining the size of the smallest detectable tumor. This work shows how to overcome such intrinsic limitation by substituting scintillating crystals with pixelated CdTe detectors. The proposed novel design is developed within the Voxel Imaging PET (VIP) Pathfinder project and evaluated via Monte Carlo simulation. The volumetric spatial resolution of the VIP-PEM is expected to be up to 6 times better than standard commercial devices with a point spread function of 1 mm full width at half maximum (FWHM) in all directions. Pixelated CdTe detectors can also provide an energy resolution as low as 1.5% FWHM at 511 keV for a virtually pure signal with negligible contribution from scattered events.

  16. Pixelated CdTe detectors to overcome intrinsic limitations of crystal based positron emission mammographs

    PubMed Central

    De Lorenzo, G.; Chmeissani, M.; Uzun, D.; Kolstein, M.; Ozsahin, I.; Mikhaylova, E.; Arce, P.; Cañadas, M.; Ariño, G.; Calderón, Y.

    2013-01-01

    A positron emission mammograph (PEM) is an organ dedicated positron emission tomography (PET) scanner for breast cancer detection. State-of-the-art PEMs employing scintillating crystals as detection medium can provide metabolic images of the breast with significantly higher sensitivity and specificity with respect to standard whole body PET scanners. Over the past few years, crystal PEMs have dramatically increased their importance in the diagnosis and treatment of early stage breast cancer. Nevertheless, designs based on scintillators are characterized by an intrinsic deficiency of the depth of interaction (DOI) information from relatively thick crystals constraining the size of the smallest detectable tumor. This work shows how to overcome such intrinsic limitation by substituting scintillating crystals with pixelated CdTe detectors. The proposed novel design is developed within the Voxel Imaging PET (VIP) Pathfinder project and evaluated via Monte Carlo simulation. The volumetric spatial resolution of the VIP-PEM is expected to be up to 6 times better than standard commercial devices with a point spread function of 1 mm full width at half maximum (FWHM) in all directions. Pixelated CdTe detectors can also provide an energy resolution as low as 1.5% FWHM at 511 keV for a virtually pure signal with negligible contribution from scattered events. PMID:23750176

  17. Overview of positron emission tomography chemistry: clinical and technical considerations and combination with computed tomography.

    PubMed

    Koukourakis, G; Maravelis, G; Koukouraki, S; Padelakos, P; Kouloulias, V

    2009-01-01

    The concept of emission and transmission tomography was introduced by David Kuhl and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania. Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at the Washington University School of Medicine. Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a 3-dimensional image or map of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional space within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine. If the biologically active molecule chosen for PET is 18F-fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged give tissue metabolic activity in terms of regional glucose uptake. Although use of this tracer results in the most common type of PET scan, other tracer molecules are used in PET to image the tissue concentration of many other types of molecules of interest. The main role of this article was to analyse the available types of radiopharmaceuticals used in PET-CT along with the principles of its clinical and technical considerations.

  18. Clinical evaluation of a high-resolution (2. 6-mm) positron emission tomography

    SciTech Connect

    Valk, P.E.; Jagust, W.J.; Derenzo, S.E.; Huesman, R.H.; Geyer, A.B.; Budinger, T.F. )

    1990-09-01

    The intrinsic resolution of the Donner 600-crystal positron emission tomograph (PET 600) is 2.6 mm full width at half maximum (FWHM) in-plane and 6 mm FWHM axially. More than 100 patients with glioma, radiation necrosis, Alzheimer disease, or epilepsy have been studied with this system. Approximately 1 million events are acquired in 15 minutes, starting 1 hour after injection of 10 mCi (370 MBq) of fluorine-18-fluorodeoxyglucose. Normal structures as small as the superior colliculi and the external capsule have been resolved. Improved separation of the cortical ribbon from adjacent white matter has allowed more accurate determination of cortical metabolic rate. In two of 15 patients undergoing evaluation for recurrent glioma, the PET 600 images showed tumor uptake that was not apparent on a lower-resolution study. A high-activity orbiting transmission source with electronic collimation allows accurate, short-duration transmission measurements to be made after radiopharmaceutical administration. The anatomic detail seen on the transmission images can be used for reproducible patient positioning with an accuracy of 1-2 mm perpendicular to the image plane. These findings demonstrate the practicality and clinical effectiveness of high-resolution positron emission tomography.

  19. Imaging in breast cancer: Single-photon computed tomography and positron-emission tomography

    PubMed Central

    Bénard, François; Turcotte, Éric

    2005-01-01

    Although mammography remains a key imaging method for the early detection and screening of breast cancer, the overall accuracy of this test remains low. Several radiopharmaceuticals have been proposed as adjunct imaging methods to characterize breast masses by single-photon-emission computed tomography (SPECT) and positron-emission tomography (PET). Useful in characterizing indeterminate palpable masses and in the detection of axillary metastases, these techniques are insufficiently sensitive to detect subcentimetric tumor deposits. Their role in staging nodal involvement of the axillary areas therefore currently remains limited. Several enzymes and receptors have been targeted for imaging breast cancers with PET. [18F]Fluorodeoxyglucose is particularly useful in the detection and staging of recurrent breast cancer and in assessing the response to chemotherapy. Several other ligands targeting proliferative activity, protein synthesis, and hormone and cell-membrane receptors may complement this approach by providing unique information about biological characteristics of breast cancer across primary and metastatic tumor sites. PMID:15987467

  20. 18F-AV-1451 positron emission tomography in Alzheimer's disease and progressive supranuclear palsy.

    PubMed

    Passamonti, Luca; Vázquez Rodríguez, Patricia; Hong, Young T; Allinson, Kieren S J; Williamson, David; Borchert, Robin J; Sami, Saber; Cope, Thomas E; Bevan-Jones, W Richard; Jones, P Simon; Arnold, Robert; Surendranathan, Ajenthan; Mak, Elijah; Su, Li; Fryer, Tim D; Aigbirhio, Franklin I; O'Brien, John T; Rowe, James B

    2017-03-01

    The ability to assess the distribution and extent of tau pathology in Alzheimer's disease and progressive supranuclear palsy in vivo would help to develop biomarkers for these tauopathies and clinical trials of disease-modifying therapies. New radioligands for positron emission tomography have generated considerable interest, and controversy, in their potential as tau biomarkers. We assessed the radiotracer 18F-AV-1451 with positron emission tomography imaging to compare the distribution and intensity of tau pathology in 15 patients with Alzheimer's pathology (including amyloid-positive mild cognitive impairment), 19 patients with progressive supranuclear palsy, and 13 age- and sex-matched controls. Regional analysis of variance and a support vector machine were used to compare and discriminate the clinical groups, respectively. We also examined the 18F-AV-1451 autoradiographic binding in post-mortem tissue from patients with Alzheimer's disease, progressive supranuclear palsy, and a control case to assess the 18F-AV-1451 binding specificity to Alzheimer's and non-Alzheimer's tau pathology. There was increased 18F-AV-1451 binding in multiple regions in living patients with Alzheimer's disease and progressive supranuclear palsy relative to controls [main effect of group, F(2,41) = 17.5, P < 0.0001; region of interest × group interaction, F(2,68) = 7.5, P < 0.00001]. More specifically, 18F-AV-1451 binding was significantly increased in patients with Alzheimer's disease, relative to patients with progressive supranuclear palsy and with control subjects, in the hippocampus and in occipital, parietal, temporal, and frontal cortices (t's > 2.2, P's < 0.04). Conversely, in patients with progressive supranuclear palsy, relative to patients with Alzheimer's disease, 18F-AV-1451 binding was elevated in the midbrain (t = 2.1, P < 0.04); while patients with progressive supranuclear palsy showed, relative to controls, increased 18F-AV-1451 uptake in the putamen, pallidum

  1. Relation between tumor FDG uptake and hematologic prognostic indicators in stage I lung cancer patients following curative resection

    PubMed Central

    Jeong, Eugene; Hyun, Seung Hyup; Moon, Seung Hwan; Cho, Young Seok; Kim, Byung-Tae; Lee, Kyung-Han

    2017-01-01

    Abstract Hematologic parameters of systemic inflammation are receiving attention as promising prognostic indicators in cancer patients. Here, we investigated the relation and compared the prognostic values of circulating blood cell-based parameters and tumor 18F-fluoro-2-deoxyglucose (FDG) uptake in patients with stage I nonsmall cell lung cancers (NSCLC). Subjects were 1034 patients with newly diagnosed stage I NSCLC who underwent FDG positron emission tomography/computed tomography (PET/CT) followed by curative resection. Total white blood cell (WBC) count, absolute neutrophil, lymphocyte and platelet counts, neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR) were obtained. Tumor FDG uptake was measured as SUVmax. WBC, neutrophil and lymphocyte counts, and NLR demonstrated weak but significant correlation to tumor SUVmax. Using the upper quartile as cutoff, patients with high tumor SUVmax had significantly higher WBC, neutrophil and lymphocyte counts, and greater NLR. There were 144 recurrences (13.9%) over a median follow-up of 29.5 months. On Cox proportional hazards regression analysis, WBC count, tumor SUVmax, age, gender, smoking, cell type, and tumor stage were significant univariate prognostic factors. On multivariate analysis, high tumor SUVmax (HR = 2.22; 95% CI, 1.52–3.25; P < 0.001), tumor stage 1B (HR = 2.11; 95% CI, 1.47–3.01; P < 0.001), and old age (HR = 1.03; 95% CI, 1.01–1.05; P = 0.002) were significant independent predictors of poor survival. Finally, high tumor SUVmax remained a significant predictor of prognosis in both low and WBC count groups. Circulating blood counts showed significant correlation to tumor FDG uptake in early stage NSCLC. WBC count was a significant univariate variable, but tumor FDG uptake was a superior and independent predictor of outcome. Hence, tumor FDG uptake effectively stratified prognosis in patients with low as well as high WBC count. PMID:28151879

  2. Conventional and Nuclear Medicine Imaging in Ectopic Cushing's Syndrome: A Systematic Review

    PubMed Central

    Isidori, Andrea M.; Sbardella, Emilia; Zatelli, Maria Chiara; Boschetti, Mara; Vitale, Giovanni; Colao, Annamaria

    2015-01-01

    Context: Ectopic Cushing's Syndrome (ECS) can be a diagnostic challenge with the hormonal source difficult to find. This study analyzes the accuracy of imaging studies in ECS localization. Evidence Acquisition: Systematic review of medical literature for ECS case series providing individual patient data on at least one conventional imaging technique (computed tomography [CT]/magnetic resonance imaging) and one of the following: 111In-pentetreotide (OCT), 131I/123I-metaiodobenzylguanidine, 18F-fluoro-2-deoxyglucose-positron emission tomography (FDG-PET), 18F-fluorodopa-PET (F-DOPA-PET), 68Ga-DOTATATE-PET/CT or 68Ga-DOTATOC-PET/CT scan (68Gallium-SSTR-PET/CT). Evidence Summary: The analysis comprised 231 patients (females, 50.2%; age, 42.6 ± 17 y). Overall, 52.4% (121/231) had “overt” ECS, 18.6% had “occult” ECS, and 29% had “covert” ECS. Tumors were located in the lung (55.3%), mediastinum-thymus (7.9%), pancreas (8.5%), adrenal glands (6.4%), gastrointestinal tract (5.4%), thyroid (3.7%), and other sites (12.8%), and primary tumors were mostly bronchial neuroendocrine tumors (NETs) (54.8%), pancreatic NETs (8%), mediastinum-thymus NETs (6.9%), gastrointestinal NETs (5.3%), pheochromocytoma (6.4%), neuroblastoma (3.2%), and medullary thyroid carcinoma (3.2%). Tumors were localized by CT in 66.2% (137/207), magnetic resonance imaging in 51.5% (53/103), OCT in 48.9% (84/172), FDG-PET in 51.7% (46/89), F-DOPA-PET in 57.1% (12/21), 131/123I-metaiodobenzylguanidine in 30.8% (4/13), and 68Gallium-SSTR-PET/CT in 81.8% (18/22) of cases. Molecular imaging discovered 79.1% (53/67) of tumors unidentified by conventional radiology, with OCT the most commonly used, revealing the tumor in 64%, followed by FDG-PET in 59.4%. F-DOPA-PET was used in only seven covert cases (sensitivity, 85.7%). Notably, 68Gallium-SSTR-PET/CT had 100% sensitivity among covert cases. Conclusions: Nuclear medicine improves the sensitivity of conventional radiology when tumor site

  3. Inter- and Intra- observer agreement of FDG-PET/CT image interpretation in patients referred for assessment of Cardiac Sarcoidosis.

    PubMed

    Ohira, Hiroshi; Mc Ardle, Brian; deKemp, Robert A; Nery, Pablo B; Juneau, Daniel; Renaud, Jennifer M; Klein, Ran; Clarkin, Owen; MacDonald, Karen; Leung, Eugene; Nair, Girish; Beanlands, Rob S B; Birnie, David

    2017-03-02

    Recent studies have reported the usefulness of (18)F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in aiding with the diagnosis and management of patients with cardiac sarcoidosis (CS). However, the image interpretation of FDG-PET for CS is sometimes challenging. We sought to investigate the inter- and intra-observer agreement and explore factors which lead to important discrepancies between readers. METHODS: We studied consecutive patients with no significant coronary artery disease who were referred for assessment of CS. Two experienced readers blinded to clinical information, imaging reports, independently reviewed FDG-PET/CT images. FDG-PET/CT images were interpreted according to a predefined standard operating procedure, with cardiac FDG uptake patterns categorized into 5 patterns; 1) none, 2) focal, 3) focal on diffuse, 4) diffuse and 5) isolated lateral wall and/or basal uptake. Overall image assessment was classified as either consistent with active CS or not. RESULTS: One hundred scans were included from 71 patients. Of these, 46 underwent FDG-PET/CT with no-restricted diet (no-restriction group) and 54 underwent FDG-PET/CT with low-carbohydrate, high fat and protein-permitted diet (low-carb group). There was agreement of the interpretation category in 74 of 100 scans. Kappa value of agreement among all 5 categories was 0.64 indicating moderate agreement. For overall clinical interpretation, there was agreement in 93 of 100 scans (kappa = 0.85). When scans were divided into the preparation groups; there was trend towards higher agreement in the low-carb group vs no-restriction (80% vs 67%, P = 0.08). Regarding the overall clinical interpretation, there was also trend towards greater agreement in the low-carb group vs no-restriction (96% vs 89%, P = 0.08). CONCLUSION: The inter-observer agreement of cardiac FDG uptake image patterns was moderate. However, agreement was better regarding overall interpretation of CS. Detailed pre-scan dietary

  4. A Prospective Study of {sup 18}FDG-PET With CT Coregistration for Radiation Treatment Planning of Lymphomas and Other Hematologic Malignancies

    SciTech Connect

    Terezakis, Stephanie A.; Schöder, Heiko; Kowalski, Alexander; McCann, Patrick; Lim, Remy; Turlakov, Alla; Gonen, Mithat; Barker, Chris; Goenka, Anuj; Lovie, Shona; Yahalom, Joachim

    2014-06-01

    Purpose: This prospective single-institution study examined the impact of positron emission tomography (PET) with the use of 2-[{sup 18}F] fluoro-2-deoxyglucose and computed tomography (CT) scan radiation treatment planning (TP) on target volume definition in lymphoma. Methods and Materials: 118 patients underwent PET/CT TP during June 2007 to May 2009. Gross tumor volume (GTV) was contoured on CT-only and PET/CT studies by radiation oncologists (ROs) and nuclear medicine physicians (NMPs) for 95 patients with positive PET scans. Treatment plans and dose-volume histograms were generated for CT-only and PET/CT for 95 evaluable sites. Paired t test statistics and Pearson correlation coefficients were used for analysis. Results: 70 (74%) patients had non-Hodgkin lymphoma, 10 (11%) had Hodgkin lymphoma, 12 (10%) had plasma-cell neoplasm, and 3 (3%) had other hematologic malignancies. Forty-three (45%) presented with relapsed/refractory disease. Forty-five (47%) received no prior chemotherapy. The addition of PET increased GTV as defined by ROs in 38 patients (median, 27%; range, 5%-70%) and decreased GTV in 41 (median, 39.5%; range, 5%-80%). The addition of PET increased GTV as defined by NMPs in 27 patients (median, 26.5%; range, 5%-95%) and decreased GTV in 52 (median, 70%; range, 5%-99%). The intraobserver correlation between CT-GTV and PET-GTV was higher for ROs than for NMPs (0.94, P<.01 vs 0.89, P<.01). On the basis of Bland-Altman plots, the PET-GTVs defined by ROs were larger than those defined by NMPs. On evaluation of clinical TPs, only 4 (4%) patients had inadequate target coverage (D95 <95%) of the PET-GTV defined by NMPs. Conclusions: Significant differences between the RO and NMP volumes were identified when PET was coregistered to CT for radiation planning. Despite this, the PET-GTV defined by ROs and NMPs received acceptable prescription dose in nearly all patients. However, given the potential for a marginal miss, consultation with an experienced PET

  5. Routine positron emission tomography and positron emission tomography/computed tomography in melanoma staging with positive sentinel node biopsy is of limited benefit.

    PubMed

    Constantinidou, Anastasia; Hofman, Michael; O'Doherty, Michael; Acland, Katharine M; Healy, Ciaran; Harries, Mark

    2008-02-01

    Positron emission tomography (PET) is increasingly used for the staging and management of melanoma. The aim of this study was to evaluate the role of PET or PET/ computed tomography (CT) as a routine procedure in patients with positive sentinel node biopsy (SNB). Thirty patients with melanoma of Breslow thickness greater than 1 mm who had PET or PET/CT scans performed within 100 days after a positive SNB were reviewed retrospectively. Two patients (6%) had a positive PET scan, none of which were melanoma related. The first patient had a synchronous neuroendocrine thyroid tumour and the second patient had increased uptake in the chest wall, which proved to be old trauma. Lymph node dissection was positive in five cases (16%). With a median follow-up of 24 months, 21 patients remained disease free. In none of the 30 cases did the early PET scan after a positive SNB alter subsequent melanoma management. The role of PET scanning soon after a positive sentinel node biopsy seems to be of limited benefit. It is questionable whether any imaging is beneficial at this stage. The results of this review suggest that PET scanning might not be indicated for this group of patients.

  6. Positron emission tomography microdosing: a new concept with application in tracer and early clinical drug development.

    PubMed

    Bergström, Mats; Grahnén, Anders; Långström, Bengt

    2003-09-01

    The realisation that new chemical entities under development as drug candidates fail in three of four cases in clinical trials, together with increased costs and increased demands of reducing preclinical animal experiments, have promoted concepts for improvement of early screening procedures in humans. Positron emission tomography (PET) is a non-invasive imaging technology, which makes it possible to determine drug distribution and concentration in vivo in man with the drug labelled with a positron-emitting radionuclide that does not change the biochemical properties. Recently, developments in the field of rapid synthesis of organic compounds labelled with positron-emitting radionuclides have allowed a substantial number of new drug candidates to be labelled and potentially used as probes in PET studies. Together, these factors led to the logical conclusion that early PET studies, performed with very low drug doses-PET-microdosing-could be included in the drug development process as one means for selection or rejection of compounds based on performance in vivo in man. Another important option of PET, to evaluate drug interaction with a target, utilising a PET tracer specific for this target, necessitates a more rapid development of such PET methodology and validations in humans. Since only very low amounts of drugs are used in PET-microdosing studies, the safety requirements should be reduced relative to the safety requirements needed for therapeutic doses. In the following, a methodological scrutinising of the concept is presented. A complete pre-clinical package including limited toxicity assessment is proposed as a base for the regulatory framework of the PET-microdosing concept.

  7. Quantitative imaging of I-124 using positron emission tomography with applications to radioimmunodiagnosis and radioimmunotherapy

    SciTech Connect

    Pentlow, K.S.; Graham, M.C.; Lambrecht, R.M.; Cheung, N.K.; Larson, S.M. )

    1991-05-01

    Positron emission tomography (PET) is potentially useful for the quantitative imaging of radiolabeled antibodies, leading in turn to improved dosimetry in radioimmunotherapy. Iodine-124 is a positron-emitting nuclide with appropriate chemical properties and half-life (4.2 days) for such studies since the radiolabeling of antibodies with iodine is well understood and the half-life permits measurements over several days. Unfortunately, I-124 has a complex decay scheme with many high-energy gamma rays and a positron abundance of only 25%. It has therefore been largely ignored as a PET-imaging nuclide. However, measurements made with phantoms and animals under realistic conditions using a BGO-based PET scanner have shown that satisfactory imaging and quantitation can be achieved. Investigations of spatial resolution, the linearity of regional observed count rate versus activity in the presence of other activity, and the visualization and quantitation of activity in spheres with different surrounding background activities were carried out with phantoms up to 22 cm in diameter. Compared with F-18, spatial resolution was only slightly degraded (13.5 mm FWHM vs 12 mm FWHM) while linearity was the same over a 10:1 activity range (0.015 to 0.15 MBq/ml for I-124). The visualization and quantitation of spheres was also slightly degraded when using similar imaging times. Increasing the imaging time for I-124 reduced the difference. To verify that the technique would work in vivo, measurements were made of human neuroblastoma tumors in rats which had been injected with I-124 labeled 3F8 antibody. Although the number of samples was small, good agreement was achieved between image-based measurements and direct measurements of excised 4-g tumors. Thus quantitative imaging of I-124 labeled antibodies appears to be possible under realistic conditions.

  8. Positron emission tomography in the quantification of cellular and biochemical responses to intrapulmonary particulates

    SciTech Connect

    Jones, Hazel A. . E-mail: hazel.jones@imperial.ac.uk; Hamacher, Kurt; Clark, John C.; Schofield, John B.; Krausz, Thomas; Haslett, Christopher; Boobis, Alan R.

    2005-09-01

    Inhaled mineral dusts and fibres can cause chronic pulmonary inflammation, often leading to permanent scarring with loss of function, but the mechanisms involved remain obscure. There are currently no good methods for monitoring inflammatory processes in situ. Positron emission tomography (PET) of suitable intravenously injected radiolabelled markers provides non-invasive and repeatable methods of quantifying biochemical and cellular responses. We have developed animal models of fibrotic and non-fibrotic pulmonary response to particulate instillation and characterised these by histology. Different components of the inflammatory response have been investigated by PET: (1) [{sup 18}F]-labelled fluoro-deoxyglucose, a positron emitting glucose analogue, accumulates in cells in proportion to their glucose uptake; ex vivo microautoradiography indicates that neutrophils are the cells responsible for an increased signal during pulmonary inflammation; a persistently high uptake is associated with lung scarring. (2) The radioligand [{sup 11}C]-R-PK11195 binds to benzodiazepine-like receptors abundant in macrophages; following particulate instillation, the [{sup 11}C]-R-PK11195 PET signal tracks with lung macrophage accumulation and also localises to regions consistent with macrophage clearance; poor macrophage clearance is associated with fibrosis. (3) [{sup 18}F]-fluoroproline is likely a substrate for extracellular matrix production, especially proline-rich collagen; during active scarring, the rate of lung uptake of fluoroproline is elevated. Localisation of radioactivity in the lung has been validated ex vivo by microautoradiography of tritium analogues of each of the positron emitting tracers. The use of PET to monitor different inflammatory processes by repeated scanning of the same animal or individual is helping to identify key events in the fibrotic process.

  9. Studies of discrete symmetries in a purely leptonic system using the Jagiellonian Positron Emission Tomograph

    NASA Astrophysics Data System (ADS)

    Moskal, P.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Gajos, A.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Khreptak, O.; Korcyl, G.; Kowalski, P.; Krzemień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Pawlik-Niedńwiecka, M.; Raczyński, L.; Rudy, Z.; Silarski, M.; Smyrski, J.; Wieczorek, A.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.

    2016-11-01

    Discrete symmetries such as parity (P), charge-conjugation (C) and time reversal (T) are of fundamental importance in physics and cosmology. Breaking of charge conjugation symmetry (C) and its combination with parity (CP) constitute necessary conditions for the existence of the asymmetry between matter and antimatter in the observed Universe. The presently known sources of discrete symmetries violations can account for only a tiny fraction of the excess of matter over antimatter. So far CP and T symmetries violations were observed only for systems involving quarks and they were never reported for the purely leptonic objects. In this article we describe briefly an experimental proposal for the test of discrete symmetries in the decays of positronium atom which is made exclusively of leptons. The experiments are conducted by means of the Jagiellonian Positron Emission Tomograph (J-PET) which is constructed from strips of plastic scintillators enabling registration of photons from the positronium annihilation. J-PET tomograph together with the positronium target system enable to measure expectation values for the discrete symmetries odd operators constructed from (i) spin vector of the ortho-positronium atom, (ii) momentum vectors of photons originating from the decay of positronium, and (iii) linear polarization direction of annihilation photons. Linearly polarized positronium will be produced in the highly porous aerogel or polymer targets, exploiting longitudinally polarized positrons emitted by the sodium 22Na isotope. Information about the polarization vector of orthopositronium will be available on the event by event basis and will be reconstructed from the known position of the positron source and the reconstructed position of the orthopositronium annihilation. In 2016 the first tests and calibration runs are planned, and the data collection with high statistics will commence in the year 2017.

  10. Randomized Trial of Neuroprotective Effects of Erythropoietin in Patients Receiving Adjuvant Chemotherapy for Breast Cancer: Positron Emission Tomography and Neuropsychological Study

    DTIC Science & Technology

    2008-09-01

    Effects of Erythropoietin in Patients Receiving Adjuvant Chemotherapy for Breast Cancer : Positron Emission Tomography and Neuropsychological Study...Neuroprotective Effects of Erythropoietin in Patients 5a. CONTRACT NUMBER Receiving Adjuvant Chemotherapy for Breast Cancer : Positron Emission Tomography...11 Introduction In the United States approximately 60-80% of patients diagnosed with breast cancer will receive

  11. Positron emission mammography (PEM): A promising technique for detecting breast cancer

    SciTech Connect

    Thompson, C.J.; Murthy, K.; Picard, Y.; Mako, R.; Weinberg, I.N.

    1995-08-01

    The authors are developing a high specificity technique for detecting the increased metabolic rate of breast tumors. The glucose analog FDG is known to concentrate in breast tumors rendering them easily detectable in conventional PET scans. Since PET is a relatively expensive imaging technique it has not been used routinely in the detection of breast cancer. Positron emission mammography (PEM) will provide a highly efficient, high spatial resolution, and low cost positron imaging system whose metabolic images are co-registered with conventional mammography. Coincidences between two BGO blocks cut into 2 x 2 mm squares coupled to two 7.5 cm square imaging PMTs are detected and back-projected to form real-time multiple plane images. The design is about 20 times more sensitive than a conventional multi-slice PET body scanner, so much less radio-pharmaceutical can be used, reducing the patient dose and cost per scan. Prototype detectors have been made and extensive measurements done. The device is expected to have an in-plane spatial resolution about 2 mm FWHM. Besides the application as a secondary screening tool the device may be beneficial in measuring a tumor`s response to radio-therapy or chemo-therapy, as well as aiding the surgeon in optimizing the removal of malignant tissue.

  12. Positron emission tomography (PET): expanding the horizons of oncology drug development.

    PubMed

    Hammond, Lisa A; Denis, Louis; Salman, Umber; Jerabek, Paul; Thomas, Charles R; Kuhn, John G

    2003-08-01

    Positron emission tomography (PET) allows three-dimensional quantitative determination of the distribution of radioactivity permitting measurement of physiological, biochemical, and pharmacological functions at the molecular level. Until recently, no method existed to directly and noninvasively assess transport and metabolism of neoplastic agents as a function of time in various organs as well as in the tumor. Standard preclinical evaluation of potential anticancer agents entails radiolabeling the agent, usually with tritium or 14C, sacrifice experiments, and high-performance liquid chromatography (HPLC) analysis to determine the biodistribution and metabolism in animals. Radiolabeling agents with positron-emitting radionuclides allows the same information to be obtained as well as in vivo pharmacokinetic (PK) data by animal tissue and plasma sampling in combination with PET scanning. In phase I/II human studies, classic PK measurements can be coupled with imaging measurements to define an optimal dosing schedule and help formulate the design of phase III studies that are essential for drug licensure [1]. Many of the novel agents currently in development are cytostatic rather than cytotoxic and therefore, the traditional standard endpoints in phase I and II studies may no longer be relevant. The use of a specialized imaging modality that allows PK and pharmacodynamic (PD) evaluation of a drug of interest has been proposed to permit rapid and sensitive assessment of the biological effects of novel anticancer agents. The progress to date and the challenges of incorporating PET technology into oncology drug development from the preclinical to clinical setting are reviewed in this article.

  13. Cosmic ray electrons, positrons and the synchrotron emission of the Galaxy: consistent analysis and implications

    SciTech Connect

    Bernardo, Giuseppe Di; Evoli, Carmelo; Gaggero, Daniele; Grasso, Dario; Maccione, Luca E-mail: carmelo.evoli@desy.de E-mail: dario.grasso@pi.infn.it

    2013-03-01

    A multichannel analysis of cosmic ray electron and positron spectra and of the diffuse synchrotron emission of the Galaxy is performed by using the DRAGON code. This study is aimed at probing the interstellar electron source spectrum down to E ∼< 1GeV and at constraining several propagation parameters. We find that above 4GeV the e{sup −} source spectrum is compatible with a power-law of index ∼ 2.5. Below 4GeV instead it must be significantly suppressed and the total lepton spectrum is dominated by secondary particles. The positron spectrum and fraction measured below a few GeV are consistently reproduced only within low reacceleration models. We also constrain the scale-height z{sub t} of the cosmic-ray distribution using three independent (and, in two cases, original) arguments, showing that values of z{sub t} ∼< 2kpc are excluded. This result may have strong implications for particle dark matter searches.

  14. Measurement of human cerebral blood flow with (15O)butanol and positron emission tomography

    SciTech Connect

    Berridge, M.S.; Adler, L.P.; Nelson, A.D.; Cassidy, E.H.; Muzic, R.F.; Bednarczyk, E.M.; Miraldi, F. )

    1991-09-01

    Although H2(15)O is widely used for CBF measurement by positron tomography, it underestimates CBF, especially at elevated flow rates. Several tracers, including butanol, overcome this problem, but the short half-life of 15O provides advantages that cause water to remain the tracer of choice. The authors report the first use and evaluation of 15O-labeled butanol for CBF measurement. Flow measurements made in a similar fashion with water and butanol at 10-min intervals were compared in normal volunteers under resting and hypercapnic conditions. Regional analysis showed good agreement between the tracers at low flows, and significant underestimation of flow by water relative to butanol in regions of elevated flow. The observed relationship between the tracers and the curve-fitted permeability-surface area product for water (133 ml.100 g-1.min-1) follow the known relationship between water and true flow. These observations indicate that (15O)-butanol provided accurate measurements of human regional CBF under conditions of elevated perfusion. They conclude that butanol is a convenient and accurate method for routine CBF determination by positron emission tomography.

  15. Pretargeted Positron Emission Tomography Imaging That Employs Supramolecular Nanoparticles with in Vivo Bioorthogonal Chemistry.

    PubMed

    Hou, Shuang; Choi, Jin-Sil; Garcia, Mitch Andre; Xing, Yan; Chen, Kuan-Ju; Chen, Yi-Ming; Jiang, Ziyue K; Ro, Tracy; Wu, Lily; Stout, David B; Tomlinson, James S; Wang, Hao; Chen, Kai; Tseng, Hsian-Rong; Lin, Wei-Yu

    2016-01-26

    A pretargeted oncologic positron emission tomography (PET) imaging that leverages the power of supramolecular nanoparticles with in vivo bioorthogonal chemistry was demonstrated for the clinically relevant problem of tumor imaging. The advantages of this approach are that (i) the pharmacokinetics (PKs) of tumor-targeting and imaging agents can be independently altered via chemical alteration to achieve the desired in vivo performance and (ii) the interplay between the two PKs and other controllable variables confers a second layer of control toward improved PET imaging. In brief, we utilized supramolecular chemistry to synthesize tumor-targeting nanoparticles containing transcyclooctene (TCO, a bioorthogonal reactive motif), called TCO⊂SNPs. After the intravenous injection and subsequent concentration of the TCO⊂SNPs in the tumors of living mice, a small molecule containing both the complementary bioorthogonal motif (tetrazine, Tz) and a positron-emitting radioisotope ((64)Cu) was injected to react selectively and irreversibly to TCO. High-contrast PET imaging of the tumor mass was accomplished after the rapid clearance of the unreacted (64)Cu-Tz probe. Our nanoparticle approach encompasses a wider gamut of tumor types due to the use of EPR effects, which is a universal phenomenon for most solid tumors.

  16. 11C=O Bonds Made Easily for Positron Emission Tomography Radiopharmaceuticals

    PubMed Central

    Rotstein, Benjamin H.; Liang, Steven H.; Placzek, Michael S.; Hooker, Jacob M.; Gee, Antony D.; Dollé, Frédéric; Wilson, Alan A.; Vasdev, Neil

    2016-01-01

    The positron-emitting radionuclide carbon-11 (11C, t1/2 = 20.3 minutes) possesses the unique potential for radiolabeling of any biological, naturally occurring, or synthetic organic molecule for in vivo positron emission tomography (PET) imaging. Carbon-11 is most often incorporated into small molecules by methylation of alcohol, thiol, amine or carboxylic acid precursors using [11C]methyl iodide or [11C]methyl triflate (generated from [11C]CO2). Consequently, small molecules that lack an easily substituted 11C-methyl group are often considered to have non-obvious strategies for radiolabeling and require a more customized approach. [11C]Carbon dioxide, [11C]carbon monoxide, [11C]cyanide, and [11C]phosgene represent alternative carbon-11 reactants to enable 11C-carbonylation. Methodologies developed for preparation of 11C-carbonyl groups have had a tremendous impact on the development of novel PET radiopharmaceuticals and provided key tools for clinical research. 11C-Carbonyl radiopharmaceuticals based on labeled carboxylic acids, amides, carbamates, and ureas now account for a substantial number of important imaging agents that have seen translation to higher species and clinical research of previously inaccessible targets, which is a testament to the creativity, utility, and practicality of the underlying radiochemistry. PMID:27276357

  17. Evaluation of positron emission tomography as a method to visualize subsurface microbial processes

    SciTech Connect

    Kinsella K.; Schlyer D.; Kinsella, K.; Schlyer, D.J.; Fowler, J.S.; Martinez, R.J.; Sobecky, P.A.

    2012-01-18

    Positron emission tomography (PET) provides spatiotemporal monitoring in a nondestructive manner and has higher sensitivity and resolution relative to other tomographic methods. Therefore, this technology was evaluated for its application to monitor in situ subsurface bacterial activity. To date, however, it has not been used to monitor or image soil microbial processes. In this study, PET imaging was applied as a 'proof-of-principle' method to assess the feasibility of visualizing a radiotracer labeled subsurface bacterial strain (Rahnella sp. Y9602), previously isolated from uranium contaminated soils and shown to promote uranium phosphate precipitation. Soil columns packed with acid-purified simulated mineral soils were seeded with 2-deoxy-2-[{sup 18}F]fluoro-d-glucose ({sup 18}FDG) labeled Rahnella sp. Y9602. The applicability of [{sup 18}F]fluoride ion as a tracer for measuring hydraulic conductivity and {sup 18}FDG as a tracer to identify subsurface metabolically active bacteria was successful in our soil column studies. Our findings indicate that positron-emitting isotopes can be utilized for studies aimed at elucidating subsurface microbiology and geochemical processes important in contaminant remediation.

  18. Development of a treatment planning system for BNCT based on positron emission tomography data: preliminary results

    NASA Astrophysics Data System (ADS)

    Cerullo, N.; Daquino, G. G.; Muzi, L.; Esposito, J.

    2004-01-01

    Present standard treatment planning (TP) for glioblastoma multiforme (GBM - a kind of brain tumor), used in all boron neutron capture therapy (BNCT) trials, requires the construction (based on CT and/or MRI images) of a 3D model of the patient head, in which several regions, corresponding to different anatomical structures, are identified. The model is then employed by a computer code to simulate radiation transport in human tissues. The assumption is always made that considering a single value of boron concentration for each specific region will not lead to significant errors in dose computation. The concentration values are estimated "indirectly", on the basis of previous experience and blood sample analysis. This paper describes an original approach, with the introduction of data on the in vivo boron distribution, acquired by a positron emission tomography (PET) scan after labeling the BPA (borono-phenylalanine) with the positron emitter 18F. The feasibility of this approach was first tested with good results using the code CARONTE. Now a complete TPS is under development. The main features of the first version of this code are described and the results of a preliminary study are presented. Significant differences in dose computation arise when the two different approaches ("standard" and "PET-based") are applied to the TP of the same GBM case.

  19. A positron emission particle tracking investigation of the flow regimes in tumbling mills

    NASA Astrophysics Data System (ADS)

    Govender, I.; Pathmathas, T.

    2017-01-01

    Using positron emission particle tracking (PEPT) data we recover key granular rheology ingredients (velocity, shear rate, volume concentration, bed depth) for developing, testing and calibrating granular flow models. In this regard, 5 mm glass beads were rotated within a 476 mm diameter mill fitted with angled lifter bars along the inner azimuthal walls and operated in batch mode across a range of drum rotation speeds that span cascading and cataracting Froude regimes. After averaging the PEPT outputs into representative volume elements, subsequent continuum analysis of the flowing layer revealed a rich coexistence of flow regimes: a quasi-static layer dominated by frictional interactions, a dense, liquid-like layer that is stressed by frictional and collisional interactions, and an inertial layer that interacts mainly through collisions. Combining the inertial number with an empirically formulated dilatancy law and the measured granular rheological ingredients then facilitated the recovery of the total depth-dependent pressure of the free surface layer.

  20. An 8×8 Row-Column Summing Readout Electronics for Preclinical Positron Emission Tomography Scanners

    PubMed Central

    Shih, Y. C.; Sun, F. W.; MacDonald, L. R.; Otis, B. P.; Miyaoka, R. S.; McDougald, W.; Lewellen, T. K.

    2010-01-01

    This work presents a row/column summing readout electronics for an 8×8 silicon photomultiplier array. The summation circuit greatly reduces the number of electronic channels, which is desirable for pursuing higher resolution positron emission tomography scanners. By using a degenerated common source topology in the summation circuit, more fan-in is possible and therefore a greater reduction in the number of electronic channels can be achieved. The timing signal is retrieved from a common anode, which allows the use of a single fast-sampling analog to digital converter (ADC) for the timing channel and slower, lower power ADCs for the 64 spatial channels. Preliminary results of one row summation of the 8×8 readout electronics exhibited FWHM energy resolution of 17.8% and 18.3% with and without multiplexing, respectively. The measured timing resolution is 2.9ns FWHM. PMID:20729983

  1. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    PubMed Central

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  2. Regional cerebral glucose metabolic rate in human sleep assessed by positron emission tomography

    SciTech Connect

    Buchsbaum, M.S.; Wu, J.; Hazlett, E.; Sicotte, N.; Bunney, W.E. Jr. ); Gillin, J.C. )

    1989-01-01

    The cerebral metabolic rate of glucose was measured during nighttime sleep in 36 normal volunteers using positron emission tomography and fluorine-18-labeled 2-deoxyglucose (FDG). In comparison to waking controls, subjects given FDG during non-rapid eye movement (NREM) sleep showed about a 23% reduction in metabolic rate across the entire brain. This decrease was greater for the frontal than temporal or occipital lobes, and greater for basal ganglia and thalamus than cortex. Subjects in rapid eye movement (REM) sleep tended to have higher cortical metabolic rates than walking subjects. The cingulate gyrus was the only cortical structure to show a significant increase in glucose metabolic rate in REM sleep in comparison to waking. The basal ganglia were relatively more active on the right in REM sleep and symmetrical in NREM sleep.

  3. Myelin imaging with C-11 labeled diphenylmethanol and positron emission tomography

    SciTech Connect

    Herscovitch, P.; Dischino, D.D.; Kilbourn, M.R.; Welch, M.J.; Raichle, M.E.

    1985-05-01

    The authors have recently studied several C-11-labeled radiopharmaceuticals for their suitability as myelin imaging agents with positron emission tomography (PET). C-11 diphenylmethanol (DPM) was selected on the basis of its in vivo metabolic stability and high extraction and lipophilicity. PET studies were performed in three normal subjects and in one patient with multiple sclerosis (MS). Myelin distribution was imaged following the bolus intravenous administration of 25-30 mCi of C-11 DPM. Sequential scans were obtained after radiotracer administration to measure the DPM distribution as a function of time. In addition, regional cerebral blood flow was measured after the bolus intravenous injection of 0-15 water. A tomographic slice through the centrum semiovale was used to obtain regional data for gray matter (GM) and white matter (WM).

  4. The Use and Misuse of Positron Emission Tomography in Lung Cancer Evaluation

    PubMed Central

    Chang, Ching-Fei; Rashtian, Afshin; Gould, Michael K.

    2011-01-01

    Synopsis Positron emission tomography (PET) has been studied for a variety of indications in patients with known or suspected non-small cell lung cancer (NSCLC). In this review, we discuss the potential benefits and limitations of PET for characterizing lung nodules, staging the mediastinum, identifying occult distant metastasis, determining prognosis and treatment response, guiding plans for radiation therapy, restaging during and after treatment, and selecting targets for tissue sampling. (Table 1) Evidence from randomized, controlled trials supports the use of PET for initial staging in NSCLC, while lower quality evidence from studies of diagnostic accuracy and modeling studies supports the use of PET for characterizing lung nodules. For most other indications in NSCLC, additional studies are required to clarify the role of PET and determine who is most likely to benefit. PMID:22054883

  5. Extramedullary Plasmacytoma of the Gallbladder Detected on Fluorine 18-fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    PubMed Central

    Fakhri, Asif Ali; Rodrigue, Paul David; Fakhri, Amena Fatima

    2016-01-01

    Extramedullary plasmacytoma is rare in patients with diagnosed multiple myeloma. Soft tissue plasmacytoma of the gallbladder is particularly uncommon and has been described in only a handful of cases. Diagnosis of gallbladder plasmacytoma with fluorine 18-fluorodeoxyglucose (F18-FDG) positron emission tomography/computed tomography (PET/CT) has not previously been reported. We present a 65-year-old female with a history of multiple myeloma who underwent a restaging F18-FDG-PET/CT which showed a focal area of hypermetabolic activity, corresponding to a nodular lesion within the posterior gallbladder wall. The patient underwent successful cholecystectomy, with surgical pathology revealing gallbladder plasmacytoma. A follow-up scan was negative for active malignancy. This is a novel case of gallbladder plasmacytoma diagnosed on whole-body F18-FDG PET/CT – thus demonstrating the clinical value of this imaging modality in staging, restaging, and surveillance for patients with multiple myeloma. PMID:27761300

  6. Positron emission tomography demonstrated localized luxury perfusion in subacute sclerosing panencephalitis.

    PubMed

    Yoshikawa, H; Fueki, N; Yoneyama, H; Ogawa, M; Sakuragawa, N

    1990-10-01

    Positron emission tomography (PET) was performed on two patients in different stages of subacute sclerosing panencephalitis (SSPE) and compared with the concurrent computed tomography (CT) findings and clinical status. Case 1, which was in stage II, showed luxury perfusion in the anterior half of the cerebrum and decreases of cerebral blood flow and oxygen metabolism in the right frontal watershed zone, where CT showed low density. Case 2, which was in stage III, showed marked decreases of cerebral blood flow and cerebral metabolic rate of oxygen in all regions except the occipital region. The present PET study demonstrated that SSPE showed inflammatory-destructive progression and rostral-caudal progression. Further, it was suspected that low density on CT scan, especially in the watershed zone, resulted partly from disturbances in cerebral circulation.

  7. Magnetic field calculation for a 10 MeV positron emission tomography cyclotron.

    PubMed

    Chen, Dezhi; Chen, Zihao; Liu, Kaifeng; Yang, Jun; Li, Dong; Qin, Bin; Xiong, Yongqian

    2013-05-01

    The magnetic field calculation and correction for a 10 MeV positron emission tomography cyclotron is presented. 3D TOSCA analysis results are compared with the measured data, and the calculation error is used to calibrate the B-H curve to obtain a very precise finite element method estimator, which is used to predict the correction of the magnet pole for achieving the isochronous field. The isochronous field error is approximated with the effects of a set of standard patches. On the assumption that the effect of each small patch is proportional to its surface, the correction of the magnet pole is found by solving a system of equations using the least square scheme. The magnet shimming is performed and the measured magnetic field is found in good agreement with the prediction, with an error less than 2 G.

  8. Regional brain glucose metabolism in chronic schizophrenia. A positron emission transaxial tomographic study

    SciTech Connect

    Farkas, T.; Wolf, A.P.; Jaeger, J.; Brodie, J.D.; Christman, D.R.; Fowler, J.S.

    1984-03-01

    Thirteen diagnosed schizophrenics and 11 normal controls were studied with a method using the PETT III positron emission tomograph (PET) and fluorodeoxyglucose labeled with fluorine 18. Each subject also had a computed tomographic (CT) scan. For each subject, two brain levels, one through the basal ganglia and one through the semioval center, were analyzed for the mean regional metabolic glucose rate. Specifically, relationships between frontal and posterior regions were evaluated. The CT scans of matching levels were superimposed on the functional PET images to provide anatomic criteria for region of interest selection. While no whole-slice metabolic differences were apparent between groups, schizophrenics had significantly lower activity in the frontal lobes, relative to posterior regions. The medicated and drug-free groups did not differ from one another in these regards. Trait v state dependency of the phenomenon was analyzed, and several technological limitations were considered.

  9. Positron emission tomography in minor ischemic stroke using oxygen-15 steady-state technique

    SciTech Connect

    Pozzilli, C.; Itoh, M.; Matsuzawa, T.; Fukuda, H.; Abe, Y.; Sato, T.; Takeda, S.; Ido, T.

    1987-04-01

    A study with positron emission tomography (PET) was performed on 10 patients with ischemic stroke and mild disability. The patients underwent cerebral angiography, x-ray computed tomography (CT) scan and regional cerebral measurements of CBF, CMRO2, oxygen extraction ratio (OER), and cerebral blood volume (CBV). Only minor arterial involvement was detected by angiography. In all patients, PET images of functional defects were more extensive than the corresponding CT hypodensity, and there were statistically significant reductions in CBF, CMRO2, and CBF/CBV ratio as compared with control subjects. Half of the regions analyzed in the affected hemisphere demonstrated a disruption of the normal coupling between CBF and CMRO2 as reflected by OER values significantly higher or lower than those of the corresponding region of the contralateral hemisphere. The pathophysiological pattern of high OER combined with a reduction in CBF proportionally greater than the reduction in CMRO2 was particularly indicative of regional chronic hemodynamic compromise in these patients.

  10. 18F-FDG positron emission tomography in oncology: main indications.

    PubMed

    Vercher-Conejero, J L; Gámez Cenzano, C

    2016-01-01

    The development of molecular and functional imaging with new imaging techniques such as computed tomography, magnetic resonance imaging, and positron emission tomography (PET) among others, has greatly improved the detection of tumors, tumor staging, and the detection of possible recurrences. Furthermore, the combination of these different imaging modalities and the continual development of radiotracers for PET have advanced our understanding and knowledge of the different pathophysiological processes in cancer, thereby helping to make treatment more efficacious, improving patients' quality of life, and increasing survival. PET is one of the imaging techniques that has attracted the most interest in recent years for its diagnostic capabilities. Its ability to anatomically locate pathologic foci of metabolic activity has revolutionized the detection and staging of many tumors, exponentially broadening its potential indications not only in oncology but also in other fields such as cardiology, neurology, and inflammatory and infectious diseases.

  11. Refraction-compensated motion tracking of unrestrained small animals in positron emission tomography.

    PubMed

    Kyme, Andre; Meikle, Steven; Baldock, Clive; Fulton, Roger

    2012-08-01

    Motion-compensated radiotracer imaging of fully conscious rodents represents an important paradigm shift for preclinical investigations. In such studies, if motion tracking is performed through a transparent enclosure containing the awake animal, light refraction at the interface will introduce errors in stereo pose estimation. We have performed a thorough investigation of how this impacts the accuracy of pose estimates and the resulting motion correction, and developed an efficient method to predict and correct for refraction-based error. The refraction model underlying this study was validated using a state-of-the-art motion tracking system. Refraction-based error was shown to be dependent on tracking marker size, working distance, and interface thickness and tilt. Correcting for refraction error improved the spatial resolution and quantitative accuracy of motion-corrected positron emission tomography images. Since the methods are general, they may also be useful in other contexts where data are corrupted by refraction effects.

  12. Positron emission tomography suggests that the rate of progression of idiopathic parkinsonism is slow

    SciTech Connect

    Bhatt, M.H.; Snow, B.J.; Martin, W.R.; Pate, B.D.; Ruth, T.J.; Calne, D.B. )

    1991-06-01

    The authors performed sequential positron emission tomography scans with 6-(18F)fluoro-L-dopa in 9 patients with idiopathic parkinsonism and 7 age-matched normal control subjects to compare changes in the nigrostriatal dopaminergic pathway over time. The mean interval between the scans was 3.3 years for the group with idiopathic parkinsonism and 3.9 years for the control subjects. The scans were analyzed by calculating the ratio of striatal to background radioactivity. Both groups showed statistically significant reductions of striatal uptake over the interval. The rate of decrease was almost identical in each group (p = 0.6). They infer that the usual rate of loss of integrity of the dopaminergic nigrostriatal pathway in patients with idiopathic parkinsonism is slow and the rate of change between the two groups was comparable.

  13. Imaging amyloid in Parkinson's disease dementia and dementia with Lewy bodies with positron emission tomography.

    PubMed

    Brooks, David J

    2009-01-01

    Although Parkinson's disease with later dementia (PDD) and dementia with Lewy bodies (DLB) are pathologically characterized by the presence of intraneuronal Lewy inclusion bodies, amyloid deposition is also associated to varying degrees with both these disorders. Fibrillar amyloid load can now be quantitated in vivo with positron emission tomography (PET) using imaging biomarkers. Here the reported findings of 11C-PIB PET studies concerning the amyloid load associated with PD and its influence on dementia are reviewed. It is concluded that the presence of amyloid acts to accelerate the dementia process in Lewy body disorders, though has little influence on its nature. Anti-amyloid strategies could be a relevant approach for slowing dementia in a number of DLB and PDD cases.

  14. The impact of positron emission tomography imaging on the clinical management of patients with epilepsy.

    PubMed

    Juhász, Csaba

    2012-06-01

    Clinical positron emission tomography (PET) imaging of human epilepsy has a 30-year history, but it is still searching for its exact role among rapidly advancing neuroimaging techniques. The vast majority of epilepsy PET studies used this technique to improve detection of epileptic foci for surgical resection. Here, we review the main trends emerging from three decades of PET research in epilepsy, with a particular emphasis on how PET imaging has impacted on the clinical management of patients with intractable epilepsy. While reviewing the latest studies, we also present an argument for a changing role of PET and molecular imaging in the future, with an increasing focus on epileptogenesis and newly discovered molecular mechanisms of epilepsy. These new applications will be facilitated by technological advances, such as the use of integrated PET/MRI systems and utilization of novel radiotracers, which may also enhance phenotype-genotype correlations and assist rational, individualized treatment strategies.

  15. Greater left cerebral hemispheric metabolism in bulimia assessed by positron emission tomography

    SciTech Connect

    Wu, J.C.; Hagman, J.; Buchsbaum, M.S.; Blinder, B.; Derrfler, M.; Tai, W.Y.; Hazlett, E.; Sicotte, N. )

    1990-03-01

    Eight women with bulimia and eight age- and sex-matched normal control subjects were studied with positron emission tomography using (18F)-fluorodeoxyglucose (FDG) as a tracer of brain metabolic rate. Subjects performed a visual vigilance task during FDG uptake. In control subjects, the metabolic rate was higher in the right hemisphere than in the left, but patients with bulimia did not have this normal asymmetry. Lower metabolic rates in the basal ganglia, found in studies of depressed subjects, and higher rates in the basal ganglia, reported in a study of anorexia nervosa, were not found. This is consistent with the suggestion that bulimia is a diagnostic grouping distinct from these disorders.

  16. Receptor-specific positron emission tomography radiopharmaceuticals: /sup 75/Br-labeled butyrophenone neuroleptics

    SciTech Connect

    Moerlein, S.M.; Stoecklin, G.; Weinhard, K.; Pawlik, G.; Heiss, W.D.

    1985-11-01

    Cerebral dopaminergic D/sub 2/ receptors are involved in several common disease states, such as schizophrenia, Parkinson's disease, and Huntington's chorea. The use of radiolabeled D/sub 2/ receptor-binding ligands with positron emission tomography (PET) to noninvasively quantitate D/sub 2/ receptor densities thus has potential application in medicine. Butyrophenone neuroleptics have a high in vitro and in vivo binding affinity for cerebral D/sub 2/ receptors, and due to the useful chemical and nuclear decay properties of /sup 74/Br (76% ..beta../sup +/, half-life = 1.6 h), the authors have evaluated radiobrominated bromospiperone (BSP), brombenperidol (BBP), and bromperidol (BP) as radiopharmaceuticals for use with PET.

  17. Caffeine and human cerebral blood flow: A positron emission tomography study

    SciTech Connect

    Cameron, O.G.; Modell, J.G.; Hariharan, M. )

    1990-01-01

    Positron emission tomography (PET) was used to quantify the effect of caffeine on whole brain and regional cerebral blood flow (CBF) in humans. A mean dose of 250 mg of caffeine produced approximately a 30% decrease in whole brain CBF; regional differences in caffeine effect were not observed. Pre-caffeine CBF strongly influenced the magnitude of the caffeine-induced decrease. Caffeine decreased p{sub a}CO{sub 2} and increased systolic blood pressure significantly; the change in p{sub a}CO{sub 2} did not account for the change in CBF. Smaller increases in diastolic blood pressure, heart rate, plasma epinephrine and norepinephrine, and subjectively reported anxiety were also observed.

  18. Nicotine Blocks Brain Estrogen Synthase (Aromatase): In Vivo Positron Emission Tomography Studies in Female Baboons

    SciTech Connect

    Biegon, A.; Biegon, A.; Kim, S.-W.; Logan, J.; Hooker, J.M.; Muench, L.; Fowler, J.S.

    2010-01-12

    Cigarette smoking and nicotine have complex effects on human physiology and behavior, including some effects similar to those elicited by inhibition of aromatase, the last enzyme in estrogen biosynthesis. We report the first in vivo primate study to determine whether there is a direct effect of nicotine administration on brain aromatase. Brain aromatase availability was examined with positron emission tomography and the selective aromatase inhibitor [{sup 11}C]vorozole in six baboons before and after exposure to IV nicotine at .015 and .03 mg/kg. Nicotine administration produced significant, dose-dependent reductions in [{sup 11}C]vorozole binding. The amygdala and preoptic area showed the largest reductions. Plasma levels of nicotine and its major metabolite cotinine were similar to those found in cigarette smokers. Nicotine interacts in vivo with primate brain aromatase in regions involved in mood, aggression, and sexual behavior.

  19. Clinical Utility of Positron Emission Tomography Magnetic Resonance Imaging (PET-MRI) in Gastrointestinal Cancers.

    PubMed

    Matthews, Robert; Choi, Minsig

    2016-09-09

    Anatomic imaging utilizing both CT (computed tomography) and MRI (magnetic resonance imaging) limits the assessment of cancer metastases in lymph nodes and distant organs while functional imaging like PET (positron emission tomography) scan has its limitation in spatial resolution capacity. Hybrid imaging utilizing PET-CT and PET-MRI are novel imaging modalities that are changing the current landscape in cancer diagnosis, staging, and treatment response. MRI has shown to have higher sensitivity in soft tissue, head and neck pathology, and pelvic disease, as well as, detecting small metastases in the liver and bone compared to CT. Combining MRI with PET allows for detection of metastases that may have been missed with current imaging modalities. In this review, we will examine the clinical utility of FDG PET-MRI in the diagnosis and staging of gastrointestinal cancers with focus on esophageal, stomach, colorectal, and pancreatic cancers. We will also explore its role in treatment response and future directions associated with it.

  20. Parametric imaging via kinetics-induced filter for dynamic positron emission tomography.

    PubMed

    Bian, Zhaoying; Huang, Jing; Lu, Lijun; Ma, Jianhua; Zeng, Dong; Feng, Qianjin; Chen, Wufan

    2013-01-01

    Due to the noisy measurement of the voxel-wise time activity curve (TAC), parametric imaging for dynamic positron emission tomography (PET) is a challenging task. To address this problem, some spatial filters, such as Gaussian filter, bilateral filter, wavelet-based filter, and so on, are often performed to reduce the noise of each frame. However, these filters usually just consider local properties of each frame without exploring the kinetic information. In this paper, aiming to improve the quantitative accuracy of parametric imaging, we present a kinetics-induced filter to lower the noise of dynamic PET images by incorporating the kinetic information. The present kinetics-induced filter is designed via the similarity between voxel-wise TACs under the framework of bilateral filter. Experimental results with a simulation study demonstrate that the present kinetics-induced filter can achieve noticeable gains than other existing methods for parametric images in terms of quantitative accuracy measures.

  1. [Fluorodeoxyglucose and bronchopulmonary cancer. Initial French results with positron emission tomography].

    PubMed

    Vaylet, F; Foehrenbach, H; De Dreuille, O; Maszelin, P; Merlet, P; Bendriem, B; L'Her, P; Syrota, A; Gaillard, J F

    1998-09-01

    Despite recent advances, the contribution of medical imaging techniques is limited, particularly in terms of tissue characterization, in the diagnosis of pulmonary nodules and search for extension of bronchogenic cancer. The metabolic properties of the glucose analog deoxyglucose labeled with 18F1 would allow metabolic imaging. Positron emission tomography (PET) provides clinicians with quality images with an interesting sensitivity. We report the results of a feasibility study conducted in our first 17 patients. We observed 14 true positives, 1 true negative and 1 false positive and 1 false negative in patients with a malignant primary lesion. We analyzed the causes of error. Ten disseminated localizations were identified. Possible developments in terms of therapeutic strategy are discussed. The agreement between our findings and data reported in the literature prompted us to develop a study protocol using 18-fluorodeoxyglucose PET in patients with bronchogenic cancer.

  2. Combined positron emission tomography and computed tomography to visualize and quantify fluid flow in sedimentary rocks

    NASA Astrophysics Data System (ADS)

    Fernø, M. A.; Gauteplass, J.; Hauge, L. P.; Abell, G. E.; Adamsen, T. C. H.; Graue, A.

    2015-09-01

    Here we show for the first time the combined positron emission tomography (PET) and computed tomography (CT) imaging of flow processes within porous rocks to quantify the development in local fluid saturations. The coupling between local rock structure and displacement fronts is demonstrated in exploratory experiments using this novel approach. We also compare quantification of 3-D temporal and spatial water saturations in two similar CO2 storage tests in sandstone imaged separately with PET and CT. The applicability of each visualization technique is evaluated for a range of displacement processes, and the favorable implementation of combining PET/CT for laboratory core analysis is discussed. We learn that the signal-to-noise ratio (SNR) is over an order of magnitude higher for PET compared with CT for the studied processes.

  3. Hemiballismus: Study of a case using positron emission tomography with 18fluoro-2-deoxyglucose

    SciTech Connect

    Dubinsky, R.M.; Greenberg, M.; Di Chiro, G.; Baker, M.; Hallett, M. )

    1989-01-01

    A 64-year-old man had right-sided persistent hemiballismus. Cerebral computed tomography (CT) and 0.5-T magnetic resonance imaging (MRI) showed no abnormalities, but 1.5-T MRI showed decreased signal intensity of the putamina, greater on the left than on the right. The subthalamic area was normal on CT and MRI. Positron emission tomography with 18fluoro2-deoxyglucose showed marked hypometabolism of the left putamen (60% of the right) and hypermetabolism of the left parietal lobe (138% of the right). The decreased metabolism of the left putamen may indicate a reduction in neuronal firing. The pathophysiology of the hemiballismus in this case may be loss of tonic inhibition of the lateral globus pallidus from the putamen, leading in turn to greater inhibition of the subthalamic nucleus, less excitation of the medial globus pallidus, and less inhibition of the thalamus and motor cortex, and thus allowing expression of the ballistic movements.

  4. Current status of positron emission tomography radiotracers for serotonin receptors in humans.

    PubMed

    Zimmer, Luc; Le Bars, Didier

    2013-01-01

    Serotonin (5-HT) neurotransmission plays a key modulatory role in the brain. This system is critical for pathophysiological processes and many drug treatments for brain disorders interact with its 14 subtypes of receptors. Positron emission tomography (PET) is a unique tool for the study of the living brain in translational studies from animal models to patients in neurology or psychiatry. This short review is intended to cover the current status of PET radioligands used for imaging human brain 5-HT receptors. Here, we describe the available PET radioligands for the 5-HT1A , 5-HT1B , 5-HT2A , 5-HT4 and 5-HT6 receptors. Finally, we highlight the future challenges for a functional PET imaging of serotonin receptors, including the research towards specific PET radiotracers for yet unexplored serotonin receptors, the need of radiotracers for endogenous serotonin level measurement and the contribution of agonist radiotracers for functional imaging of 5-HT neurotransmission.

  5. Hypoxia imaging using Positron Emission Tomography in non-small cell lung cancer: implications for radiotherapy.

    PubMed

    Bollineni, Vikram Rao; Wiegman, Erwin M; Pruim, Jan; Groen, Harry J M; Langendijk, Johannes A

    2012-12-01

    Tumour hypoxia is an important contributor to radioresistance. Thus, increasing the radiation dose to hypoxic areas may result in improved locoregional tumour control. However, this strategy requires accurate detection of the hypoxic sub-volume using PET imaging. Secondly, hypoxia imaging may also provide prognostic information and may be of help to monitor treatment response. Therefore, a systematic review of the scientific literature was carried out on the use of Positron Emission Tomography (PET) to image Tumour hypoxia in non-small cell lung cancer (NSCLC). More specifically, the purpose of this review was (1) to summarize the different hypoxia tracers used, (2) to investigate whether Tumour hypoxia can be detected in NSCLC and finally (3) whether the presence of hypoxia can be used to predict outcome.

  6. Optical imaging of reporter gene expression using a positron-emission-tomography probe

    NASA Astrophysics Data System (ADS)

    Liu, Hongguang; Ren, Gang; Liu, Shuanglong; Zhang, Xiaofen; Chen, Luxi; Han, Peizhen; Cheng, Zhen

    2010-11-01

    Reporter gene/reporter probe technology is one of the most important techniques in molecular imaging. Lately, many reporter gene/reporter probe systems have been coupled to different imaging modalities such as positron emission tomography (PET) and optical imaging (OI). It has been recently found that OI techniques could be used to monitor radioactive tracers in vitro and in living subjects. In this study, we further demonstrate that a reporter gene/nuclear reporter probe system [herpes simplex virus type-1 thymidine kinase (HSV1-tk) and 9-(4-18F-fluoro-3-[hydroxymethyl] butyl) guanine ([18F]FHBG)] could be successfully imaged by OI in vitro and in vivo. OI with radioactive reporter probes will facilitate and broaden the applications of reporter gene/reporter probe techniques in medical research.

  7. Investigation of Abnormal Left Temporal Functioning in Dyslexia through rCBF, Auditory Evoked Potentials, and Positron Emission Tomography.

    ERIC Educational Resources Information Center

    Wood, Frank; And Others

    1991-01-01

    Investigates the proposed left hemisphere dysfunction in dyslexia by reviewing four studies using regional cerebral blood flow (RCBF) and combined auditory evoked responses with positron emission tomography. Emphasizes methodological issues. Finds that dyslexics showed a positive correlation between Heschl's gyrus activation and phonemic…

  8. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    PubMed

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted.

  9. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging in a Patient with HIV (-) Kaposi Sarcoma

    PubMed Central

    Cengiz, Arzu; Şavk, Ekin; Tataroğlu, Canten; Yürekli, Yakup

    2016-01-01

    Kaposi sarcoma (KS) is a vascular neoplasm that often manifests with multiple vascular nodules on the skin and other organs. Various imaging modalities can be used to display disease extent. Herein we present a 65-year-old female patient with human immunodeficiency virus negative KS along with her whole-body positron emission tomography/computed tomography imaging findings. PMID:27751977

  10. Rare case of an ovarian vein tumor thrombosis identified on fluorodeoxyglucose positron emission tomography/computed tomography

    PubMed Central

    Chandra, Piyush; Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    Fludeoxyglucose positron emission tomography/computed tomography is valuable in the identification of tumor thrombus and differentiating it from bland thrombus which has implications in initiating anticoagulation. We present a rare case of tumor thrombosis in ovarian vein, in a recurrent case of uterine carcinosarcoma. PMID:27833321

  11. Serotonin transporter in attention-deficit hyperactivity disorder--preliminary results from a positron emission tomography study.

    PubMed

    Karlsson, Linnea; Tuominen, Lauri; Huotarinen, Antti; Leppämäki, Sami; Sihvola, Elina; Helin, Semi; Sipilä, Maria; Tani, Pekka; Hirvonen, Jussi; Hietala, Jarmo; Karlsson, Hasse

    2013-05-30

    The serotonin transporter (SERT) in attention-deficit hyperactivity disorder (ADHD) patients has not been explored by earlier positron emission tomography (PET) studies. We measured SERT availability in female ADHD patients (n=8) and healthy controls (n=14) with PET and [11C]MADAM as a tracer. No significant group differences in [11C]MADAM binding potential were noted.

  12. Effective dose to staff members in a positron emission tomography/CT facility using zirconium-89

    PubMed Central

    2013-01-01

    Objective: Positron emission tomography (PET) using zirconium-89 (89Zr) is complicated by its complex decay scheme. In this study, we quantified the effective dose from 89Zr and compared it with fluorine-18 fludeoxyglucose (18F-FDG). Methods: Effective dose distribution in a PET/CT facility in Riyadh was calculated by Monte Carlo simulations using MCNPX. The positron bremsstrahlung, the annihilation photons, the delayed gammas from 89Zr and those emissions from 18F-FDG were modelled in the simulations but low-energy characteristic X-rays were ignored. Results: On the basis of injected activity, the dose from 89Zr was higher than that of 18F-FDG. However, the dose per scan from 89Zr became less than that from 18F-FDG near the patient, owing to the difference in injected activities. In the corridor and control rooms, the 89Zr dose was much higher than 18F-FDG, owing to the difference in attenuation by the shielding materials. Conclusion: The presence of the high-energy photons from 89Zr-labelled immuno-PET radiopharmaceuticals causes a significantly higher effective dose than 18F-FDG to the staff outside the patient room. Conversely, despite the low administered activity of 89Zr, it gives rise to a comparable or even lower dose than 18F-FDG to the staff near the patient. This interesting result raises apparently contradictory implications in the radiation protection considerations of a PET/CT facility. Advances in knowledge: To the best of our knowledge, radiation exposure to staff and public in the PET/CT unit using 89Zr has not been investigated. The ultimate output of this study will lead to the optimal design of the facility for routine use of 89Zr. PMID:23934963

  13. A Conway-Maxwell-Poisson (CMP) model to address data dispersion on positron emission tomography.

    PubMed

    Santarelli, Maria Filomena; Della Latta, Daniele; Scipioni, Michele; Positano, Vincenzo; Landini, Luigi

    2016-10-01

    Positron emission tomography (PET) in medicine exploits the properties of positron-emitting unstable nuclei. The pairs of γ- rays emitted after annihilation are revealed by coincidence detectors and stored as projections in a sinogram. It is well known that radioactive decay follows a Poisson distribution; however, deviation from Poisson statistics occurs on PET projection data prior to reconstruction due to physical effects, measurement errors, correction of deadtime, scatter, and random coincidences. A model that describes the statistical behavior of measured and corrected PET data can aid in understanding the statistical nature of the data: it is a prerequisite to develop efficient reconstruction and processing methods and to reduce noise. The deviation from Poisson statistics in PET data could be described by the Conway-Maxwell-Poisson (CMP) distribution model, which is characterized by the centring parameter λ and the dispersion parameter ν, the latter quantifying the deviation from a Poisson distribution model. In particular, the parameter ν allows quantifying over-dispersion (ν<1) or under-dispersion (ν>1) of data. A simple and efficient method for λ and ν parameters estimation is introduced and assessed using Monte Carlo simulation for a wide range of activity values. The application of the method to simulated and experimental PET phantom data demonstrated that the CMP distribution parameters could detect deviation from the Poisson distribution both in raw and corrected PET data. It may be usefully implemented in image reconstruction algorithms and quantitative PET data analysis, especially in low counting emission data, as in dynamic PET data, where the method demonstrated the best accuracy.

  14. Predicting Outcome in Patients with Rhabdomyosarcoma: Role of [{sup 18}F]Fluorodeoxyglucose Positron Emission Tomography

    SciTech Connect

    Casey, Dana L.; Wexler, Leonard H.; Fox, Josef J.; Dharmarajan, Kavita V.; Schoder, Heiko; Price, Alison N.; Wolden, Suzanne L.

    2014-12-01

    Purpose: To evaluate whether [{sup 18}F]fluorodeoxyglucose positron emission tomography (FDG-PET) response of the primary tumor after induction chemotherapy predicts outcomes in rhabdomyosarcoma (RMS). Methods and Materials: After excluding those with initial tumor resection, 107 patients who underwent FDG-PET after induction chemotherapy at Memorial Sloan Kettering Cancer Center from 2002 to 2013 were reviewed. Local control (LC), progression-free survival (PFS), and overall survival (OS) were calculated according to FDG-PET response and maximum standardized uptake value (SUV) at baseline (PET1/SUV1), after induction chemotherapy (PET2/SUV2), and after local therapy (PET3/SUV3). Receiver operator characteristic curves were used to determine the optimal cutoff for dichotomization of SUV1 and SUV2 values. Results: The SUV1 (<9.5 vs ≥9.5) was predictive of PFS (P=.02) and OS (P=.02), but not LC. After 12 weeks (median) of induction chemotherapy, 45 patients had negative PET2 scans and 62 had positive scans: 3-year PFS was 72% versus 44%, respectively (P=.01). The SUV2 (<1.5 vs ≥1.5) was similarly predictive of PFS (P=.005) and was associated with LC (P=.02) and OS (P=.03). A positive PET3 scan was predictive of worse PFS (P=.0009), LC (P=.05), and OS (P=.03). Conclusions: [{sup 18}F]fluorodeoxyglucose positron emission tomography is an early indicator of outcomes in patients with RMS. Future prospective trials may incorporate FDG-PET response data for risk-adapted therapy and early assessment of new treatment regimens.

  15. Quantitative evaluation of benzodiazepine receptors in live Papio papio baboons using positron emission tomography

    SciTech Connect

    Brouillet, E.; Chavoix, C.; Khalili-Varasteh, M.; Bottlaender, M.; Hantraye, P.; Yorke, J.C.; Maziere, M. )

    1990-10-01

    The binding of the 11C-labeled benzodiazepine antagonist Ro 15-1788 (flumazenil) was measured in the neocortex of live Papio papio baboons by positron emission tomography. This allowed us to calculate in vivo (i.e., at physiological temperature, neurotransmitters concentrations, and ionic environment) the apparent density of available benzodiazepine receptors (B'max) and the dissociation constant of Ro 15-1788 (Kd). By coadministering increasing doses of unlabeled Ro 15-1788 with (11C)Ro 15-1788 and assuming that nonsaturable radioactivity indicated the free ligand concentration, we were able to obtain saturation isotherms. We showed that a state of quasiequilibrium was reached 50 min after the administration of the radioligand. Linear Scatchard plots allowed us to calculate B'max at 78 and 50 pmol/ml of cerebral tissue in the occipital and frontal cortices, respectively. In both these areas, Kd is on the order of 6 nM, with a Hill number very close to unity. This indicates that Ro 15-1788 binds in vivo with high affinity to an homogeneous population of saturable sites. A similar measurement was carried out on a naturally photosensitive P. papio baboon. Absolute values of B'max, Kd, and Hill number were similar to those of the control baboons. Although results concerning this baboon can only be considered as a case report, this similarity may suggest that its epileptic syndrome is not related to a large change in B'max or Kd, at least in occipital and frontal cortices. Our results showed that quantitative estimation by positron emission tomography of some characteristics of benzodiazepine receptors is possible in live baboons and may represent a supplementary tool for investigating further the molecular mechanisms of benzodiazepine receptor function in physiological and physiopathological conditions.

  16. Microwave accelerated labeling methods in the synthesis of radioligands for positron emission tomography imaging.

    PubMed

    Kallmerten, Amy E; Alexander, Abigail; Wager, Krista M; Jones, Graham B

    2011-10-01

    Nuclear imaging using positron emission tomography [PET] is a powerful technique with clinical applications which include oncology, cardiovascular disease and CNS disorders. Conventional chemical syntheses of the short half-life radionuclides used in the process however imposes numerous limitations on scope of available ligands. By utilizing microwave assisted synthesis methods many of these limitations can be overcome, paving the way for the design of diverse families of agents with defined cellular targets. This review will survey recent developments in the field with emphasis on the period 2006-2011. Positron emission tomography [PET] has become one of the most powerful in vivo imaging modalities, capable of delivering mm3 resolution of radiotracer distribution and metabolism [1]. When combined with anatomic imaging methods (MRI, CT) co-registered multimode images offer the potential to track metabolic and physiologic events in diseased states and guide and accelerate clinical trials of investigational new drugs. Also, this same methodology can be used to evaluate first pass pharmacokinetics/pharmacodynamics in early stage drug discovery. Though powerful as a technique only a limited number of drugs have seen clinical use and to date only one drug 2-fluoro-deoxy-D-glucose (FDG) has received FDA approval [2]. One of the drawbacks of PET imaging is the need for tracers labeled with an appropriate nuclide and the half-lives of these agents places special constraints on the chemical synthesis. Among the most popular are 11C (t½ =20.4 min) and 18F (t ½ =109.8 min) labeled compounds and this has resulted in a resurgence of interest in practical application of their chemistries [3,4]. This review will focus on microwave mediated methods of acceleration of organic reactions used for the production of labeled PET image contrast agents, with emphasis on the five year period 2006 to 2011.

  17. A Lower-Cost High-Resolution LYSO Detector Development for Positron Emission Mammography (PEM)

    PubMed Central

    Ramirez, Rocio A.; Zhang, Yuxuan; Liu, Shitao; Li, Hongdi; Baghaei, Hossain; An, Shaohui; Wang, Chao; Jan, Meei-Ling; Wong, Wai-Hoi

    2010-01-01

    In photomultiplier-quadrant-sharing (PQS) geometry for positron emission tomography applications, each PMT is shared by four blocks and each detector block is optically coupled to four round PMTs. Although this design reduces the cost of high-resolution PET systems, when the camera consists of detector panels that are made up of square blocks, half of the PMT’s sensitive window remains unused at the detector panel edge. Our goal was to develop a LYSO detector panel which minimizes the unused portion of the PMTs for a low-cost, high-resolution, and high-sensitivity positron emission mammography (PEM) camera. We modified the PQS design by using elongated blocks at panel edges and square blocks in the inner area. For elongated blocks, symmetric and asymmetrical reflector patterns were developed and PQS and PMT-half-sharing (PHS) arrangements were implemented in order to obtain a suitable decoding. The packing fraction was 96.3% for asymmetric block and 95.5% for symmetric block. Both of the blocks have excellent decoding capability with all crystals clearly identified, 156 for asymmetric and 144 for symmetric and peak-to-valley ratio of 3.0 and 2.3 respectively. The average energy resolution was 14.2% for the asymmetric block and 13.1% for the symmetric block. Using a modified PQS geometry and asymmetric block design, we reduced the unused PMT region at detector panel edges, thereby increased the field-of-view and the overall detection sensitivity and minimized the undetected breast region near the chest wall. This detector design and using regular round PMT allowed building a lower-cost, high-resolution and high-sensitivity PEM camera. PMID:20485510

  18. Ictal onset zone and seizure propagation delineated on ictal F-18 fluorodeoxyglucose positron emission tomography/computed tomography.

    PubMed

    Tripathi, Madhavi; Tripathi, Manjari; Garg, Ajay; Damle, Nishikant; Bal, Chandrasekhar

    2016-01-01

    The present case highlights the utility of ictal F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in delineating the seizure onset zone in a child with complex partial seizures. Although F-18 FDG PET has been successfully used to delineate interictal hypometabolism, planned ictal FDG PET, in cases with prolonged seizure activity, can provide better spatial resolution than single-photon emission CT by delineating the seizure onset zone and propagation pathway.

  19. Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry.

    PubMed

    Weinberg, I; Majewski, S; Weisenberger, A; Markowitz, A; Aloj, L; Majewski, L; Danforth, D; Mulshine, J; Cowan, K; Zujewski, J; Chow, C; Jones, E; Chang, V; Berg, W; Frank, J

    1996-07-01

    In order to optimally integrate radiotracer breast imaging within the breast clinic, anatomy and pathology should be easily correlated with functional nuclear medicine breast images. As a first step in the development of a hybrid functional/anatomic breast imaging platform with biopsy capability, a conventional X-ray mammography gantry was modified to image the compressed breast with positron emitters. Phantom studies with the positron emission mammography (PEM) device showed that a 1-cc hot spot could be detected within 5 min. A preliminary clinical trial demonstrated in vivo visualization of primary breast cancer within 4 min. For sites where positron-emitting radionuclides are available, PEM promises to achieve low-cost directed functional examination of breast abnormalities, with the potential for achieving X-ray correlation and image-guided biopsy.

  20. Real-time tumor tracking using implanted positron emission markers: concept and simulation study.

    PubMed

    Xu, Tong; Wong, Jerry T; Shikhaliev, Polad M; Ducote, Justin L; Al-Ghazi, Muthana S; Molloi, Sabee

    2006-07-01

    The delivery accuracy of radiation therapy for pulmonary and abdominal tumors suffers from tumor motion due to respiration. Respiratory gating should be applied to avoid the use of a large target volume margin that results in a substantial dose to the surrounding normal tissue. Precise respiratory gating requires the exact spatial position of the tumor to be determined in real time during treatment. Usually, fiducial markers are implanted inside or next to the tumor to provide both accurate patient setup and real-time tumor tracking. However, current tumor tracking systems require either substantial x-ray exposure to the patient or large fiducial markers that limit the value of their application for pulmonary tumors. We propose a real-time tumor tracking system using implanted positron emission markers (PeTrack). Each marker will be labeled with low activity positron emitting isotopes, such as 124I, 74As, or 84Rb. These isotopes have half-lives comparable to the duration of radiation therapy (from a few days to a few weeks). The size of the proposed PeTrack marker will be 0.5-0.8 mm, which is approximately one-half the size of markers currently employed in other techniques. By detecting annihilation gammas using position-sensitive detectors, multiple positron emission markers can be tracked in real time. A multimarker localization algorithm was developed using an Expectation-Maximization clustering technique. A Monte Carlo simulation model was developed for the PeTrack system. Patient dose, detector sensitivity, and scatter fraction were evaluated. Depending on the isotope, the lifetime dose from a 3.7 MBq PeTrack marker was determined to be 0.7-5.0 Gy at 10 mm from the marker. At the center of the field of view (FOV), the sensitivity of the PeTrack system was 240-320 counts/s per 1 MBq marker activity within a 30 cm thick patient. The sensitivity was reduced by 45% when the marker was near the edge of the FOV. The scatter fraction ranged from 12% (124I, 74As) to

  1. Real-time tumor tracking using implanted positron emission markers: Concept and simulation study

    SciTech Connect

    Xu Tong; Wong, Jerry T.; Shikhaliev, Polad M.; Ducote, Justin L.; Al-Ghazi, Muthana S.; Molloi, Sabee

    2006-07-15

    The delivery accuracy of radiation therapy for pulmonary and abdominal tumors suffers from tumor motion due to respiration. Respiratory gating should be applied to avoid the use of a large target volume margin that results in a substantial dose to the surrounding normal tissue. Precise respiratory gating requires the exact spatial position of the tumor to be determined in real time during treatment. Usually, fiducial markers are implanted inside or next to the tumor to provide both accurate patient setup and real-time tumor tracking. However, current tumor tracking systems require either substantial x-ray exposure to the patient or large fiducial markers that limit the value of their application for pulmonary tumors. We propose a real-time tumor tracking system using implanted positron emission markers (PeTrack). Each marker will be labeled with low activity positron emitting isotopes, such as {sup 124}I, {sup 74}As, or {sup 84}Rb. These isotopes have half-lives comparable to the duration of radiation therapy (from a few days to a few weeks). The size of the proposed PeTrack marker will be 0.5-0.8 mm, which is approximately one-half the size of markers currently employed in other techniques. By detecting annihilation gammas using position-sensitive detectors, multiple positron emission markers can be tracked in real time. A multimarker localization algorithm was developed using an Expectation-Maximization clustering technique. A Monte Carlo simulation model was developed for the PeTrack system. Patient dose, detector sensitivity, and scatter fraction were evaluated. Depending on the isotope, the lifetime dose from a 3.7 MBq PeTrack marker was determined to be 0.7-5.0 Gy at 10 mm from the marker. At the center of the field of view (FOV), the sensitivity of the PeTrack system was 240-320 counts/s per 1 MBq marker activity within a 30 cm thick patient. The sensitivity was reduced by 45% when the marker was near the edge of the FOV. The scatter fraction ranged from 12

  2. Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

    SciTech Connect

    Parodi, Katia

    2015-12-15

    Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy

  3. Optimised motion tracking for positron emission tomography studies of brain function in awake rats.

    PubMed

    Kyme, Andre Z; Zhou, Victor W; Meikle, Steven R; Baldock, Clive; Fulton, Roger R

    2011-01-01

    Positron emission tomography (PET) is a non-invasive molecular imaging technique using positron-emitting radioisotopes to study functional processes within the body. High resolution PET scanners designed for imaging rodents and non-human primates are now commonplace in preclinical research. Brain imaging in this context, with motion compensation, can potentially enhance the usefulness of PET by avoiding confounds due to anaesthetic drugs and enabling freely moving animals to be imaged during normal and evoked behaviours. Due to the frequent and rapid motion exhibited by alert, awake animals, optimal motion correction requires frequently sampled pose information and precise synchronisation of these data with events in the PET coincidence data stream. Motion measurements should also be as accurate as possible to avoid degrading the excellent spatial resolution provided by state-of-the-art scanners. Here we describe and validate methods for optimised motion tracking suited to the correction of motion in awake rats. A hardware based synchronisation approach is used to achieve temporal alignment of tracker and scanner data to within 10 ms. We explored the impact of motion tracker synchronisation error, pose sampling rate, rate of motion, and marker size on motion correction accuracy. With accurate synchronisation (<100 ms error), a sampling rate of >20 Hz, and a small head marker suitable for awake animal studies, excellent motion correction results were obtained in phantom studies with a variety of continuous motion patterns, including realistic rat motion (<5% bias in mean concentration). Feasibility of the approach was also demonstrated in an awake rat study. We conclude that motion tracking parameters needed for effective motion correction in preclinical brain imaging of awake rats are achievable in the laboratory setting. This could broaden the scope of animal experiments currently possible with PET.

  4. [Neurotransmitter systems in the human brain studied by positron emission tomography].

    PubMed

    Shinotoh, H

    1996-12-01

    Positron emission tomography with appropriate tracers provides unique opportunity to study neurotransmitter systems in the living human brain. PET with [18F] 6-fluoro-L-dopa (FD) provides an index of the integrity of nigrostriatal pathway, and striatal FD uptake correlates linearly with the density of nigral neurons. PET allows us to assess the progression of the nigral lesions in Parkinson's disease (PD). A 68-year-old normal female volunteer was scanned by FD-PET. Subsequently, she developed parkinsonism 3.7 years after the scan. A repeated FD-PET scan revealed a significant reduction of FD uptake by 20% over the 5.2 year interval. The results suggest a relatively short presymptomatic period with fast initial losses of nigral neurons in PD. FD-PET has been used to determine the viability of fetal graft implanted in the striatum for the treatment of PD. PET imaging of dopamine D1 and D2 receptors may be useful for the differential diagnosis of PD and striatonigral degeneration. PET reveals significant reduction of dopamine D1 and D2 receptor binding in the putamen of patients with SND, while D1 and D2 receptor binding is normal or slightly upregulated in PD. We found hypersensitivity of muscarinic cholinergic receptors in the frontal cortex of patients with PD by using PET. The result suggests a loss of ascending cholinergic system in the frontal cortex in PD, which may cause the frontal lobe dysfunction in PD. Recently, acetylcholine analogs labelled with positron emitter have been developed for measurement of brain acetylcholinesterase activity in vivo. These tracers may be useful for the assessment of ascending cholinergic system in Alzheimer's disease and PD.

  5. Analysis of optimum diameter of orbit of transmission line source in positron emission tomograph

    SciTech Connect

    Yamamoto, S.; Amano, M.; Hirose, Y.; Muira, S.; Kanno, I.

    1989-02-01

    Accurate attenuation correction is one of the most important factors to achieve quantitative measurements in positron emission tomography (PET). A transmission scan is most commonly used technique for the attenuation correction in PET. A difficulty in transmission scan is relatively long period to obtain a data with good signal-to-noise ratio. Insufficient signal-to-noise ratio of the transmission data limits that of emission data. Several approaches were reported to improve the transmission data. Those were (1) optimizing of detector threshold, (2) processing delayed coincidence sinogram before subtraction, filtering of transmission sinogram before performing attenuation correction, and (3) rejection of random and scatter coincidence by using rotating line source and information of its position. In some of these methods, additional calculation time or processing hardware is needed. The authors have estimated a relationship between ring diameter of a transmission line source and signal to noise ratio of the transmission dat. This paper aimes to analyze optimum diameter of the orbit of transmission line source in concerning to signal to noise ratio in transmission data.

  6. Graphics processing unit (GPU)-accelerated particle filter framework for positron emission tomography image reconstruction.

    PubMed

    Yu, Fengchao; Liu, Huafeng; Hu, Zhenghui; Shi, Pengcheng

    2012-04-01

    As a consequence of the random nature of photon emissions and detections, the data collected by a positron emission tomography (PET) imaging system can be shown to be Poisson distributed. Meanwhile, there have been considerable efforts within the tracer kinetic modeling communities aimed at establishing the relationship between the PET data and physiological parameters that affect the uptake and metabolism of the tracer. Both statistical and physiological models are important to PET reconstruction. The majority of previous efforts are based on simplified, nonphysical mathematical expression, such as Poisson modeling of the measured data, which is, on the whole, completed without consideration of the underlying physiology. In this paper, we proposed a graphics processing unit (GPU)-accelerated reconstruction strategy that can take both statistical model and physiological model into consideration with the aid of state-space evolution equations. The proposed strategy formulates the organ activity distribution through tracer kinetics models and the photon-counting measurements through observation equations, thus making it possible to unify these two constraints into a general framework. In order to accelerate reconstruction, GPU-based parallel computing is introduced. Experiments of Zubal-thorax-phantom data, Monte Carlo simulated phantom data, and real phantom data show the power of the method. Furthermore, thanks to the computing power of the GPU, the reconstruction time is practical for clinical application.

  7. Clustering-initiated factor analysis application for tissue classification in dynamic brain positron emission tomography.

    PubMed

    Boutchko, Rostyslav; Mitra, Debasis; Baker, Suzanne L; Jagust, William J; Gullberg, Grant T

    2015-07-01

    The goal is to quantify the fraction of tissues that exhibit specific tracer binding in dynamic brain positron emission tomography (PET). It is achieved using a new method of dynamic image processing: clustering-initiated factor analysis (CIFA). Standard processing of such data relies on region of interest analysis and approximate models of the tracer kinetics and of tissue properties, which can degrade accuracy and reproducibility of the analysis. Clustering-initiated factor analysis allows accurate determination of the time-activity curves and spatial distributions for tissues that exhibit significant radiotracer concentration at any stage of the emission scan, including the arterial input function. We used this approach in the analysis of PET images obtained using (11)C-Pittsburgh Compound B in which specific binding reflects the presence of β-amyloid. The fraction of the specific binding tissues determined using our approach correlated with that computed using the Logan graphical analysis. We believe that CIFA can be an accurate and convenient tool for measuring specific binding tissue concentration and for analyzing tracer kinetics from dynamic images for a variety of PET tracers. As an illustration, we show that four-factor CIFA allows extraction of two blood curves and the corresponding distributions of arterial and venous blood from PET images even with a coarse temporal resolution.

  8. Simulation study of respiratory-induced errors in cardiac positron emission tomography/computed tomography

    SciTech Connect

    Fitzpatrick, Gianna M.; Wells, R. Glenn

    2006-08-15

    Heart disease is a leading killer in Canada and positron emission tomography (PET) provides clinicians with in vivo metabolic information for diagnosing heart disease. Transmission data are usually acquired with {sup 68}Ge, although the advent of PET/CT scanners has made computed tomography (CT) an alternative option. The fast data acquisition of CT compared to PET may cause potential misregistration problems, leading to inaccurate attenuation correction (AC). Using Monte Carlo simulations and an anthropomorphic dynamic computer phantom, this study determines the magnitude and location of respiratory-induced errors in radioactivity uptake measured in cardiac PET/CT. A homogeneous tracer distribution in the heart was considered. The AC was based on (1) a time-averaged attenuation map (2) CT maps from a single phase of the respiratory cycle, and (3) CT maps phase matched to the emission data. Circumferential profiles of the heart uptake were compared and differences of up to 24% were found between the single-phase CT-AC method and the true phantom values. Simulation results were supported by a PET/CT canine study which showed differences of up to 10% in the heart uptake in the lung-heart boundary region when comparing {sup 68}Ge- to CT-based AC with the CT map acquired at end inhalation.

  9. Fluorodeoxyglucose-positron emission tomography in carcinoma nasopharynx: Can we predict outcomes and tailor therapy based on postradiotherapy fluorodeoxyglucose-positron emission tomography?

    PubMed Central

    Laskar, Sarbani Ghosh; Baijal, Gunjan; Rangarajan, Venkatesh; Purandare, Nilendu; Sengar, Manju; Shah, Sneha; Gupta, Tejpal; Budrukkar, Ashwini; Murthy, Vedang; Pai, Prathamesh S.; D’Cruz, A. K.; Agarwal, J. P.

    2016-01-01

    Background: Positron emission tomography-computed tomography (PET-CT) is an emerging modality for staging and response evaluation in carcinoma nasopharynx. This study was conducted to evaluate the impact of PET-CT in assessing response and outcomes in carcinoma nasopharynx. Materials and Methods: Forty-five patients of nonmetastatic carcinoma nasopharynx who underwent PET-CT for response evaluation at 10-12 weeks posttherapy between 2004 and 2009 were evaluated. Patients were classified as responders (Group A) if there was a complete response on PET-CT or as nonresponders (Group B) if there was any uptake above the background activity. Data regarding demographics, treatment, and outcomes were collected from their records and compared across the Groups A and B. Results: The median age was 41 years. 42 out of 45 (93.3%) patients had WHO Grade 2B disease (undifferentiated squamous carcinoma). 24.4%, 31.1%, 15.6, and 28.8% patients were in American Joint Committee on Cancer Stage IIb, III, Iva, and IVb. All patients were treated with neoadjuvant chemotherapy followed by concomitant chemoradiotherapy. Forty-five patients, 28 (62.2%) were classified as responders, whereas 17 (37.8%) were classified as nonresponders. There was no significant difference in the age, sex, WHO grade, and stage distribution between the groups. Compliance to treatment was comparable across both groups. The median follow-up was 25.3 months (759 days). The disease-free survival (DFS) of the group was 57.3% at 3 years. The DFS at 3 years was 87.3% and 19.7% for Group A and B, respectively (log-rank test, P < 0.001). Univariate and multivariate analysis revealed Groups to be the only significant factor predicting DFS (P value 0.002 and < 0.001, respectively). In Group B, the most common site of disease failure was distant (9, 53%). Conclusion: PET-CT can be used to evaluate response and as a tool to identify patients at higher risk of distant failure. Further, this could be exploited to identify

  10. CO2BOLD assessment of moyamoya syndrome: Validation with single photon emission computed tomography and positron emission tomography imaging

    PubMed Central

    Pellaton, Alain; Bijlenga, Philippe; Bouchez, Laurie; Cuvinciuc, Victor; Barnaure, Isabelle; Garibotto, Valentina; Lövblad, Karl-Olof; Haller, Sven

    2016-01-01

    AIM To compare the assessment of cerebrovascular reserve (CVR) using CO2BOLD magnetic resonance imaging (MRI) vs positron emission tomography (PET) and single photon emission computed tomography (SPECT) as reference standard. METHODS Ten consecutive patients (8 women, mean age of 41 ± 26 years) with moyamoya syndrome underwent 14 pre-surgical evaluations for external-internal carotid artery bypass surgery. CVR was assessed using CO2BOLD and PET (4)/SPECT (11) with a maximum interval of 36 d, and evaluated by two experienced neuroradiologists. RESULTS The inter-rater agreement was 0.81 for SPECT (excellent), 0.43 for PET (fair) and 0.7 for CO2BOLD (good). In 9/14 cases, there was a correspondence between CO2BOLD and PET/SPECT. In 4/14 cases, CVR was over-estimated in CO2BOLD, while in 1/14 case, CVR was underestimated in CO2BOLD. The sensitivity of CO2BOLD was 86% and a specificity of 43%. CONCLUSION CO2BOLD can be used for pre-surgical assessment of CVR in patients with moyamoya syndrome and combines the advantages of absent irradiation, high availability of MRI and assessment of brain parenchyma, cerebral vessels and surrogate CVR in one stop. PMID:27928470

  11. Technical aspects of real time positron emission tracking for gated radiotherapy

    SciTech Connect

    Chamberland, Marc; Xu, Tong; McEwen, Malcolm R.

    2016-02-15

    Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS

  12. Applications of Beta Particle Detection for Synthesis and Usage of Radiotracers Developed for Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Dooraghi, Alex Abreu

    Positron Emission Tomography (PET) is a noninvasive molecular imaging tool that requires the use of a radioactive compound or radiotracer which targets a molecular pathway of interest. We have developed and employed three beta particle radiation detection systems to advance PET. Specifically, the goals of these systems are to: 1. Automate dispensing of solutions containing a positron emitting isotope. 2. Monitor radioactivity on-chip during synthesis of a positron emitting radiotracer. 3. Assay cellular uptake on-chip of a positron emitting radiotracer. Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing an optimum environment for radiation workers, but also to ensure a quantitatively accurate workflow. For the first project, we describe the development and performance of a system for automated radioactivity distribution of beta particle emitting radioisotopes such as fluorine-18 (F-18). Key to the system is a radiation detector in-line with a peristaltic pump. The system demonstrates volume accuracy within 5 % for volumes of 20 muL or greater. When considering volumes of 20 muL or greater, delivered radioactivity is in agreement with the requested radioactivity as measured with the dose calibrator. The integration of the detector and pump leads to a flexible system that can accurately dispense solutions containing F-18 in radioactivity concentrations directly produced from a cyclotron (~ 0.1-1 mCi/muL), to low activity concentrations intended for preclinical mouse scans (~ 1-10 muCi/muL), and anywhere in between. Electrowetting on dielectric (EWOD) is an attractive microfluidic platform for batch synthesis of PET radiotracers. Visualization of radioisotopes on-chip is critical for synthesis optimization and technological development. For the second project, we describe the development and performance of a Cerenkov/real-time imaging system for PET radiotracer synthesis on EWOD. We also investigate

  13. Noninvasive quantification of muscarinic receptors in vivo with positron emission tomography in the dog heart

    SciTech Connect

    Delforge, J.; Janier, M.; Syrota, A.; Crouzel, C.; Vallois, J.M.; Cayla, J.; Lancon, J.P.; Mazoyer, B.M. )

    1990-10-01

    The in vivo quantification of myocardial muscarinic receptors has been obtained in six closed-chest dogs by using positron emission tomography. The dogs were injected with a trace amount of 11C-labeled methylquinuclidinyl benzilate (MQNB), a nonmetabolized antagonist of the muscarinic receptor. This was followed 30 minutes later by an injection of an excess of unlabeled MQNB (displacement experiment). Two additional injections of unlabeled MQNB with (11C)MQNB and without (11C)MQNB (second displacement experiment) were administered after 70 and 120 minutes, respectively. This protocol allowed a separate evaluation of the quantity of available receptors (B'max) as well as the association and dissociation rate constants (k+1 and k-1) in each dog. The parameters were calculated by using a nonlinear mathematical model in regions of interest over the left ventricle and the interventricular septum. The average value of B'max was 42 +/- 11 pmol/ml tissue, the rate constants k+1, k-1, and Kd were 0.6 +/- 0.1 ml.pmol-1.min-1, 0.27 +/- 0.03 ml.pmol-1.min-1, and 0.49 +/- 0.14 pmol.ml-1, respectively, taking into account the MQNB reaction volume estimated to 0.15 ml/ml tissue. Although (11C)MQNB binding would appear irreversible, our findings indicate that the association of the antagonist is very rapid and that the dissociation is far from negligible. The dissociated ligand, however, has a high probability of rebinding to a free receptor site instead of escaping into the microcirculation. We deduce that the positron emission tomographic images obtained after injecting a trace amount of (11C)MQNB are more representative of blood flow than of receptor density or affinity. We also suggest a simplified protocol consisting of a tracer injection of (11C)MQNB and a second injection of an excess of cold MQNB, which is sufficient to measure B'max and Kd in humans.

  14. High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

    SciTech Connect

    Ronzhin, A.; Los, S.; Martens, M.; Ramberg, E.; Kim, H.; Chen, C.; Kao, C.; Niessen, K.; Zatserklyaniy, A.; Mazzillo, M.; Carbone, B.; /SGS Thomson, Catania

    2011-02-01

    We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage

  15. A novel image reconstruction methodology based on inverse Monte Carlo analysis for positron emission tomography

    NASA Astrophysics Data System (ADS)

    Kudrolli, Haris A.

    2001-04-01

    A three dimensional (3D) reconstruction procedure for Positron Emission Tomography (PET) based on inverse Monte Carlo analysis is presented. PET is a medical imaging modality which employs a positron emitting radio-tracer to give functional images of an organ's metabolic activity. This makes PET an invaluable tool in the detection of cancer and for in-vivo biochemical measurements. There are a number of analytical and iterative algorithms for image reconstruction of PET data. Analytical algorithms are computationally fast, but the assumptions intrinsic in the line integral model limit their accuracy. Iterative algorithms can apply accurate models for reconstruction and give improvements in image quality, but at an increased computational cost. These algorithms require the explicit calculation of the system response matrix, which may not be easy to calculate. This matrix gives the probability that a photon emitted from a certain source element will be detected in a particular detector line of response. The ``Three Dimensional Stochastic Sampling'' (SS3D) procedure implements iterative algorithms in a manner that does not require the explicit calculation of the system response matrix. It uses Monte Carlo techniques to simulate the process of photon emission from a source distribution and interaction with the detector. This technique has the advantage of being able to model complex detector systems and also take into account the physics of gamma ray interaction within the source and detector systems, which leads to an accurate image estimate. A series of simulation studies was conducted to validate the method using the Maximum Likelihood - Expectation Maximization (ML-EM) algorithm. The accuracy of the reconstructed images was improved by using an algorithm that required a priori knowledge of the source distribution. Means to reduce the computational time for reconstruction were explored by using parallel processors and algorithms that had faster convergence rates

  16. Injectable silver nanosensors: in vivo dosimetry for external beam radiotherapy using positron emission tomography

    NASA Astrophysics Data System (ADS)

    Christensen, A. N.; Rydhög, J. S.; Søndergaard, R. V.; Andresen, T. L.; Holm, S.; Munck Af Rosenschöld, P.; Conradsen, K.; Jølck, R. I.

    2016-05-01

    Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive 106Ag, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The silver-nanosensor was investigated in a tissue equivalent thorax phantom using clinical settings and workflow for both standard fractionated radiotherapy (2 Gy) and stereotactic radiotherapy (10- and 22 Gy) in a high-energy beam setting (18 MV). The developed silver-nanosensor provided high radiopacity on the planning CT-scans sufficient for patient positioning in image-guided radiotherapy and provided dosimetric information about the absorbed dose with a 10% and 8% standard deviation for the stereotactic regimens, 10 and 22 Gy, respectively.Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive 106Ag, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The

  17. Differential diagnosis of solitary pulmonary nodules with positron emission tomography using (/sup 11/C)L-methionine

    SciTech Connect

    Kubota, K.; Matsuzawa, T.; Fujiwara, T.; Abe, Y.; Ito, M.; Hatazawa, J.; Ido, T.; Ishiwata, K.; Watanuki, S.

    1988-09-01

    Two patients with solitary pulmonary nodules, 1.5-2.0 cm in diameter, were studied by positron emission tomography using (/sup 11/C-Methyl)L-methionine (/sup 11/C-Met). Case 1 showed high accumulation of /sup 11/C-Met in the tumor, and a tumor/muscle ratio of 6.0 suggesting malignancy. Tissue obtained by biopsy revealed a squamous cell carcinoma. Case 2 showed nonspecific isotope accumulation in the tumor, and a tumor/muscle ratio of 1.2 suggesting a benign lesion. Lung biopsy demonstrated granuloma. Positron emission tomography with /sup 11/C-Met seems to be useful for the differential diagnosis of solitary lung nodules.

  18. Development of EndoTOFPET-US, a multi-modal endoscope for ultrasound and time of flight positron emission tomography

    NASA Astrophysics Data System (ADS)

    Pizzichemi, M.

    2014-02-01

    The EndoTOFPET-US project aims at delevoping a multi-modal imaging device that combines Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The goal is to obtain a coincidence time resolution of about 200 ps FWHM and sub-millimetric spatial resolution for the PET head, integrating the components in a very compact detector suitable for endoscopic use. The scanner will be exploited for the clinical test of new bio-markers especially targeted for prostate and pancreatic cancer as well as for diagnostic and surgical oncology. This paper focuses on the status of the Time-Of-Flight Positron Emission Tomograph under development for the EndoTOFPET-US project.

  19. Diffuse skeletal muscles uptake of [18F] fluorodeoxyglucose on positron emission tomography in primary muscle peripheral T-cell lymphoma.

    PubMed

    Tanaka, Yuji; Hayashi, Yuichi; Kato, Jun'ichi; Yamada, Megumi; Koumura, Akihiro; Sakurai, Takeo; Kimura, Akio; Hozumi, Isao; Hatano, Yuichiro; Hirose, Yoshinobu; Takami, Tsuyoshi; Nakamura, Hiroshi; Kasahara, Senji; Tsurumi, Hisashi; Moriwaki, Hisataka; Inuzuka, Takashi

    2011-01-01

    A 40-year-old man presented with weakness of neck extensor muscles. Cervical magnetic resonance imaging showed high-intensity areas in muscles of the left lateral cervical region on T2-weighted images. Fluorodeoxyglucose-positron emission tomography scan demonstrated striking fluorodeoxyglucose uptake by multiple skeletal muscles of the neck, chest, and abdominal region. Muscle biopsy demonstrated peripheral T-cell lymphoma, unspecified. The diagnosis was primary skeletal muscle peripheral T-cell lymphoma. Primary skeletal muscle non-Hodgkin's lymphoma of T-cell immunophenotype is extremely rare and fluorodeoxyglucose-positron emission tomography demonstrated striking fluorodeoxyglucose uptake in multiple skeletal muscles and served as a quite useful modality for the diagnosis of this patient.

  20. Amyloid deposition after cerebral hypoperfusion: evidenced on [(18)F]AV-45 positron emission tomography.

    PubMed

    Huang, Kuo-Lun; Lin, Kun-Ju; Ho, Meng-Yang; Chang, Yeu-Jhy; Chang, Chien-Hung; Wey, Shiaw-Pyng; Hsieh, Chia-Ju; Yen, Tzu-Chen; Hsiao, Ing-Tsung; Lee, Tsong-Hai

    2012-08-15

    Animal studies have shown that cerebral hypoperfusion may be associated with amyloid plaque accumulation. Amyloid plaque is known to be associated with dementia and [(18)F]AV-45 is a positron emission tomography (PET) ligand that binds to extracelluar plaques. We hypothesized that demented patients with cerebral hypoperfusion may have increased [(18)F]AV-45 uptake. Five demented patients with cerebral hypoperfusion due to unilateral carotid artery stenosis (CAS) were examined with [(18)F]AV-45 PET, and the results were compared with six elderly controls. The standard uptake value ratio (SUVR) of each region of interest (ROI) was created using whole cerebellum as the reference region. All subjects underwent magnetic resonance imaging (MRI) for obtaining structural information. Patients with dementia and unilateral CAS had a higher global [(18)F]AV-45 SUVR (1.34 ± 0.06) as compared with controls (1.10 ± 0.04, p=0.0043), especially over the frontal, temporal, precuneus, anterior cingulate and occipital regions. The statistical distribution maps revealed a significantly increased [(18)F]AV-45 SUVR in the medial frontal, caudate, thalamus, posterior cingulate, occipital and middle and superior temporal regions ipsilateral to the side of CAS (p<0.01). The present study found that cerebral [(18)F]AV-45 binding is increased in demented patients with CAS, and its distribution is lateralized to the CAS side, suggesting that amyloid-related dementia may occur under cerebral hypoperfusion.

  1. Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations

    SciTech Connect

    Mark F Smith; Raymond R Raylman; Stan Majewski; Andrew G Weisenberger

    2004-05-01

    Positron emission mammography (PEM) with tomographic acquisition using dual planar detectors rotating about the breast can obtain complete angular sampling and has the potential to improve activity estimation compared with PEM using stationary detectors. PEM tomography (PEMT) was compared with stationary PEM for point source and compressed breast phantom studies performed with a compact dual detector system. The acquisition geometries were appropriate for the target application of PEM guidance of stereotactic core biopsy. Images were reconstructed with a three-dimensional iterative maximum likelihood expectation maximization algorithm. PEMT eliminated blurring normal to the detectors seen with stationary PEM. Depth of interaction effects distorted the shape of the point spread functions for PEMT as the angular range from normal incidence of lines of response used in image reconstruction increased. Streak artifacts in PEMT for large detector rotation increments led to the development of an expression for the maximum rotation increment that maintains complete angular sampling. Studies with a compressed breast phantom were used to investigate contrast and signal-to-noise ratio (SNR) trade-offs for different sized spherical tumor models. PEMT and PEM both had advantages depending on lesion size and detector separation. The most appropriate acquisition method for specific detection or quantitation tasks requires additional investigation.

  2. Positron Emission Tomography to Elucidate Pharmacokinetic Differences of Regioisomeric Retinoid X Receptor Agonists

    PubMed Central

    2015-01-01

    RXR partial agonist NEt-4IB (2a, 6-[ethyl-(4-isobutoxy-3-isopropylphenyl)amino]pyridine-3-carboxylic acid: EC50 = 169 nM, Emax = 55%) showed a blood concentration higher than its Emax after single oral administration at 30 mg/kg to mice, and repeated oral administration at 10 mg/kg/day to KK-Ay mice afforded antitype 2 diabetes activity without the side effects caused by RXR full agonists. However, RXR full agonist NEt-3IB (1a), in which the isobutoxy and isopropyl groups of 2a are interchanged, gave a much lower blood concentration than 2a. Here we used positron emission tomography (PET) with tracers [11C]1a, [11C]2a and fluorinated derivatives [18F]1b, [18F]2b, which have longer half-lives, to examine the reason why 1a and 2a exhibited significantly different blood concentrations. As a result, the reason for the high blood concentration of 2a after oral administration was found to be linked to higher intestinal absorbability together with lower biliary excretion, compared with 1a. PMID:25815156

  3. Positron emission tomography molecular imaging of dopaminergic system in drug addiction.

    PubMed

    Hou, Haifeng; Tian, Mei; Zhang, Hong

    2012-05-01

    Dopamine (DA) is involved in drug reinforcement, but its role in drug addiction remains unclear. Positron emission tomography (PET) is the first technology used for the direct measurement of components of the dopaminergic system in the living human brain. In this article, we reviewed the major findings of PET imaging studies on the involvement of DA in drug addiction, especially in heroin addiction. Furthermore, we summarized PET radiotracers that have been used to study the role of DA in drug addiction. To investigate presynaptic function in drug addiction, PET tracers have been developed to measure DA synthesis and transport. For the investigation of postsynaptic function, several radioligands targeting dopamine one (D1) receptor and dopamine two (D2) receptor are extensively used in PET imaging studies. Moreover, we also summarized the PET imaging findings of heroin addiction studies, including heroin-induced DA increases and the reinforcement, role of DA in the long-term effects of heroin abuse, DA and vulnerability to heroin abuse and the treatment implications. PET imaging studies have corroborated the role of DA in drug addiction and increase our understanding the mechanism of drug addiction.

  4. Regional changes in extravascular lung water detected by positron emission tomography

    SciTech Connect

    Schuster, D.P.; Marklin, G.F.; Mintun, M.A.

    1986-04-01

    Regional measurements of extravascular lung water (rEVLW) were made with positron emission tomography (PET) and 15O-labeled radionuclides. The label used to measure the total lung water (TLW) content fully equilibrated with TLW prior to scanning in both dogs with normal and low cardiac outputs, and nearly so in areas of lung made edematous by oleic acid injury (the TLW values used were 97% of maximum values). Regional EVLW measurements made by PET (EVLW-PET) and gravimetric techniques in both normal and edematous lung were closely correlated (r = 0.93), and EVLW-PET increased from an average of 0.20 to 0.37 mlH/sub 2/O/ml lung (P less than 0.05) after regional lung injury. PET measurements of regional blood volume always decreased (from an average of 0.12 to 0.09 ml blood/ml lung (P less than 0.05)) after cardiac output was lowered by hemorrhage in a separate set of animals. Total EVLW (by thermodye indicator dilution) did not change. Likewise, regional EVLW remained constant in areas below the left atrium but decreased in areas above the left atrium. We conclude that PET measurements are accurate, noninvasive, and reproducible and that regional changes may be detected even when measurements of total EVLW by other methods may fail to change significantly.

  5. Modelling Random Coincidences in Positron Emission Tomography by Using Singles and Prompts: A Comparison Study

    PubMed Central

    2016-01-01

    Random coincidences degrade the image in Positron Emission Tomography, PET. To compensate for their degradation effects, the rate of random coincidences should be estimated. Under certain circumstances, current estimation methods fail to provide accurate results. We propose a novel method, “Singles–Prompts” (SP), that includes the information conveyed by prompt coincidences and models the pile–up. The SP method has the same structure than the well-known “Singles Rate” (SR) approach. Hence, SP can straightforwardly replace SR. In this work, the SP method has been extensively assessed and compared to two conventional methods, SR and the delayed window (DW) method, in a preclinical PET scenario using Monte–Carlo simulations. SP offers accurate estimates for the randoms rates, while SR and DW tend to overestimate the rates (∼10%, and 5%, respectively). With pile-up, the SP method is more robust than SR (but less than DW). At the image level, the contrast is overestimated in SR-corrected images, +16%, while SP produces the correct value. Spill–over is slightly reduced using SP instead of SR. The DW images values are similar to those of SP except for low-statistic scenarios, where DW behaves as if randoms were not compensated for. In particular, the contrast is reduced, −16%. In general, the better estimations of SP translate into better image quality. PMID:27603143

  6. Comparison of three image segmentation techniques for target volume delineation in positron emission tomography.

    PubMed

    Drever, Laura A; Roa, Wilson; McEwan, Alexander; Robinson, Don

    2007-03-09

    Incorporation of positron emission tomography (PET) data into radiotherapy planning is currently under investigation for numerous sites including lung, brain, head and neck, breast, and prostate. Accurate tumor-volume quantification is essential to the proper utilization of the unique information provided by PET. Unfortunately,target delineation within PET currently remains a largely unaddressed problem. We therefore examined the ability of three segmentation methods-thresholding, Sobel edge detection, and the watershed approach-to yield accurate delineation of PET target cross-sections. A phantom study employing well-defined cylindrical and spherical volumes and activity distributions provided an opportunity to assess the relative efficacy with which the three approaches could yield accurate target delineation in PET. Results revealed that threshold segmentation can accurately delineate target cross-sections, but that the Sobel and watershed techniques both consistently fail to correctly identify the size of experimental volumes. The usefulness of threshold-based segmentation is limited, however, by the dependence of the correct threshold (that which returns the correct area at each image slice) on target size.

  7. Positron Emission Tomography Reveals Abnormal Topological Organization in Functional Brain Network in Diabetic Patients

    PubMed Central

    Qiu, Xiangzhe; Zhang, Yanjun; Feng, Hongbo; Jiang, Donglang

    2016-01-01

    Recent studies have demonstrated alterations in the topological organization of structural brain networks in diabetes mellitus (DM). However, the DM-related changes in the topological properties in functional brain networks are unexplored so far. We therefore used fluoro-D-glucose positron emission tomography (FDG-PET) data to construct functional brain networks of 73 DM patients and 91 sex- and age-matched normal controls (NCs), followed by a graph theoretical analysis. We found that both DM patients and NCs had a small-world topology in functional brain network. In comparison to the NC group, the DM group was found to have significantly lower small-world index, lower normalized clustering coefficients and higher normalized characteristic path length. Moreover, for diabetic patients, the nodal centrality was significantly reduced in the right rectus, the right cuneus, the left middle occipital gyrus, and the left postcentral gyrus, and it was significantly increased in the orbitofrontal region of the left middle frontal gyrus, the left olfactory region, and the right paracentral lobule. Our results demonstrated that the diabetic brain was associated with disrupted topological organization in the functional PET network, thus providing functional evidence for the abnormalities of brain networks in DM. PMID:27303259

  8. Quantitative experimental monitoring of molecular diffusion in clay with positron emission tomography

    NASA Astrophysics Data System (ADS)

    Kulenkampff, Johannes; Zakhnini, Abdelhamid; Gründig, Marion; Lippmann-Pipke, Johanna

    2016-08-01

    Clay plays a prominent role as barrier material in the geosphere. The small particle sizes cause extremely small pore sizes and induce low permeability and high sorption capacity. Transport of dissolved species by molecular diffusion, driven only by a concentration gradient, is less sensitive to the pore size. Heterogeneous structures on the centimetre scale could cause heterogeneous effects, like preferential transport zones, which are difficult to assess. Laboratory measurements with diffusion cells yield limited information on heterogeneity, and pore space imaging methods have to consider scale effects. We established positron emission tomography (PET), applying a high-resolution PET scanner as a spatially resolved quantitative method for direct laboratory observation of the molecular diffusion process of a PET tracer on the prominent scale of 1-100 mm. Although PET is rather insensitive to bulk effects, quantification required significant improvements of the image reconstruction procedure with respect to Compton scatter and attenuation. The experiments were conducted with 22Na and 124I over periods of 100 and 25 days, respectively. From the images we derived trustable anisotropic diffusion coefficients and, in addition, we identified indications of preferential transport zones. We thus demonstrated the unique potential of the PET imaging modality for geoscientific process monitoring under conditions where other methods fail, taking advantage of the extremely high detection sensitivity that is typical of radiotracer applications.

  9. A new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties

    NASA Astrophysics Data System (ADS)

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-10-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) annihilation photon pair coincidence time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit of around 100 ps. On the other hand, modulation mechanisms of a material's optical properties as exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to study whether ionizing radiation can also produce fast modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately 5x10-6 is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the radiation source flux rate and average photon energy.

  10. Identifying active vascular microcalcification by 18F-sodium fluoride positron emission tomography

    PubMed Central

    Irkle, Agnese; Vesey, Alex T.; Lewis, David Y.; Skepper, Jeremy N.; Bird, Joseph L. E.; Dweck, Marc R.; Joshi, Francis R.; Gallagher, Ferdia A.; Warburton, Elizabeth A.; Bennett, Martin R.; Brindle, Kevin M.; Newby, David E.; Rudd, James H.; Davenport, Anthony P.

    2015-01-01

    Vascular calcification is a complex biological process that is a hallmark of atherosclerosis. While macrocalcification confers plaque stability, microcalcification is a key feature of high-risk atheroma and is associated with increased morbidity and mortality. Positron emission tomography and X-ray computed tomography (PET/CT) imaging of atherosclerosis using 18F-sodium fluoride (18F-NaF) has the potential to identify pathologically high-risk nascent microcalcification. However, the precise molecular mechanism of 18F-NaF vascular uptake is still unknown. Here we use electron microscopy, autoradiography, histology and preclinical and clinical PET/CT to analyse 18F-NaF binding. We show that 18F-NaF adsorbs to calcified deposits within plaque with high affinity and is selective and specific. 18F-NaF PET/CT imaging can distinguish between areas of macro- and microcalcification. This is the only currently available clinical imaging platform that can non-invasively detect microcalcification in active unstable atherosclerosis. The use of 18F-NaF may foster new approaches to developing treatments for vascular calcification. PMID:26151378

  11. Quantitation in positron emission computed tomography: 4. Effect of accidental coincidences.

    PubMed

    Hoffman, E J; Huang, S C; Phelps, M E; Kuhl, D E

    1981-06-01

    Accidental coincidences (ACs) and methods of compensation for ACs were investigated in terms of their effect on quantitation in positron emission computed tomography (ECT). Formulations of basic expressions describing the physical factors, which cause true coincidences or ACs, are presented to provide a framework of contrasting the two phenomena. Correction of image data for attenuation of the annihilation radiation or nonuniformities in detector efficiency is shown to amplify errors caused by the presence of ACs in the data. It was shown that failure to compensate for ACs caused overestimates in measurements of isotope concentrations from image data and that in many cases the overestimate was significant for relatively modest percentages of ACs in the data. Three methods of compensation for ACs were evaluated as to their accuracy and effect on statistical noise in images. It was found that nonuniform detector efficiencies could cause prominent image artifacts if an inadequate method was employed in the determination and subtraction of ACs from image data. The additional statistical noise produced in images by subtraction of ACs from total coincidence data demonstrates the advisability of minimizing AC rates in spite of an ability to adequately measure and compensate for their presence in the data.

  12. Design of a super fast three-dimensional projection system for positron emission tomography

    SciTech Connect

    Jones, W.F.; Byars, L.G.; Casey, M.E. )

    1990-04-01

    A hardware architecture for rapid three-dimensional (3D) reconstruction is considered for positron emission tomography (PET). For possibly improved PET performance, obliquely oriented lines of response (LOR) are to be collected and properly utilized by one of several experimental 3D reconstruction algorithms. Image signal-to-noise may improve. Septa removal increases the signal by allowing extra LOR collection but also increases the noise due to reduced shielding against out-of-plane events. Primary utility for all LOR collection and 3D reconstruction algorithms may lie with count starved applications. A major obstacle is the time required to compute the 3D reconstruction. Several hours are required even for general purpose computers capable of several million instructions power second. The bulk of the computations for the various reconstruction algorithms are typically in support of forward and back projection. This paper describes a VLSI based architecture which will support forward and back projection for a 3D image and 4096 2D views totaling over 25 million lines of response projected into 0.5 million voxels.

  13. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

    SciTech Connect

    Saha, Krishnendu; Straus, Kenneth J.; Glick, Stephen J.; Chen, Yu.

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  14. Positron emission tomography (PET) studies of dopaminergic/cholinergic interactions in the baboon brain

    SciTech Connect

    Dewey, S.L.; Brodie, J.D.; Fowler, J.S.; MacGregor, R.R.; Schlyer, D.J.; King, P.T.; Alexoff, D.L.; Volkow, N.D.; Shiue, C.Y.; Wolf, A.P. )

    1990-01-01

    Interactions between the dopaminergic D2 receptor system and the muscarinic cholinergic system in the corpus striatum of adult female baboons (Papio anubis) were examined using positron emission tomography (PET) combined with (18F)N-methylspiroperidol (( 18F)NMSP) (to probe D2 receptor availability) and (N-11C-methyl)benztropine (to probe muscarinic cholinergic receptor availability). Pretreatment with benztropine, a long-lasting anticholinergic drug, bilaterally reduced the incorporation of radioactivity in the corpus striatum but did not alter that observed in the cerebellum or the rate of metabolism of (18F)NMSP in plasma. Pretreatment with unlabelled NMSP, a potent dopaminergic antagonist, reduced the incorporation of (N-11C-methyl)benztropine in all brain regions, with the greatest effect being in the corpus striatum greater than cortex greater than thalamus greater than cerebellum, but did not alter the rate of metabolism of the labelled benztropine in the plasma. These reductions in the incorporation of either (18F)NMSP or (N-11C-methyl)benztropine exceeded the normal variation in tracer incorporation in repeated studies in the same animal. This study demonstrates that PET can be used as a tool for investigating interactions between neurochemically different yet functionally linked neurotransmitters systems in vivo and provides insight into the consequences of multiple pharmacologic administration.

  15. Test-Retest Repeatability of Myocardial Blood Flow Measurements using Rubidium-82 Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Efseaff, Matthew

    Rubidium-82 positron emission tomography (PET) imaging has been proposed for routine myocardial blood flow (MBF) quantification. Few studies have investigated the test-retest repeatability of this method. Same-day repeatability of rest MBF imaging was optimized with a highly automated analysis program using image-derived input functions and a dual spillover correction (SOC). The effects of heterogeneous tracer infusion profiles and subject hemodynamics on test-retest repeatability were investigated at rest and during hyperemic stress. Factors affecting rest MBF repeatability included gender, suspected coronary artery disease, and dual SOC (p < 0.001). The best repeatability coefficient for same-day rest MBF was 0.20 mL/min/g using a six-minute scan-time, iterative reconstruction, dual SOC, resting rate-pressure-product (RPP) adjustment, and a left atrium image-derived input function. The serial study repeatabilities of the optimized protocol in subjects with homogeneous RPPs and tracer infusion profiles was 0.19 and 0.53 mL/min/g at rest and stress, and 0.95 for stress / rest myocardial flow reserve (MFR). Subjects with heterogeneous tracer infusion profiles and hemodynamic conditions had significantly less repeatable MBF measurements at rest, stress, and stress/rest flow reserve (p < 0.05).

  16. A behavioral and micro positron emission tomography imaging study in a rat model of hypothyroidism.

    PubMed

    Yu, Jing; Tang, Yi-Yuang; Feng, Hong-Bo; Cheng, Xiao-Xin

    2014-09-01

    Hypothyroidism leads to somatic, neuropsychological, and psychiatric changes that are similar to depression. The mechanisms underlying the behavioral abnormalities in adult onset hypothyroidism remain ambiguous. Hypothyroidism was induced in adult male Wistar rats by the maintenance of 0.05% propylthiouracil (PTU) in drinking water for 5 weeks (hypothyroid group; HP group); control rats (CON group) received an equivalent amount of water. The open field and sucrose preference tests were employed, and the link between behavioral changes and brain glucose metabolism was evaluated using micro positron emission tomography imaging. The open field test revealed slightly decreased locomotor activity and significantly reduced rearing and defecation in the hypothyroid group. Hypothyroid rats were also characterized by decreased body weight, sucrose preference, and relative sucrose intake compared to control rats. Hypothyroidism induced reduced brain glucose metabolism in the bilateral motor cortex, the caudate putamen, the cortex cingulate, the nucleus accumbens, and the frontal association cortex. A decreased sucrose preference was positively correlated with metabolic glucose changes in the caudate putamen and the nucleus accumbens. The results indicate that the activity pattern in adult onset hypothyroidism is different from the activity pattern when hypothyroidism is induced in the developmental period of the central nervous system. Decreased sucrose preference in hypothyroid rats may be attributed to anhedonia. Furthermore, these findings suggest there may be a common mechanism underlying adult onset hypothyroidism and depression.

  17. The metabolic landscape of cortico-basal ganglionic degeneration: regional asymmetries studied with positron emission tomography.

    PubMed Central

    Eidelberg, D; Dhawan, V; Moeller, J R; Sidtis, J J; Ginos, J Z; Strother, S C; Cederbaum, J; Greene, P; Fahn, S; Powers, J M

    1991-01-01

    Regional metabolic rate for glucose (rCMRGlc) was estimated using [18F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) in five patients (four men, one woman; mean age 68; mean disease duration 2.4 years) with clinical findings consistent with the syndrome of cortico-basal ganglionic degeneration (CBGD). Left-right rCMRGlc asymmetry, (L-R)/(L + R) x 100, was calculated for 13 grey matter regions and compared with regional metabolic data from 18 normal volunteers and nine patients with asymmetrical Parkinson's disease (PD). In the CBGD group mean metabolic asymmetry values in the thalamus, inferior parietal lobule and hippocampus were greater than those measured in normal control subjects and patients with asymmetrical PD (p less than 0.02). Parietal lobe asymmetry of 5% or more was evident in all CBGD patients, whereas in PD patients and normal controls, all regional asymmetry measures were less than 5% in absolute value. Measures of frontal, parietal and hemispheric metabolic asymmetry were found to be positively correlated with asymmetries in thalamic rCMRGlc (p less than 0.05). The presence of cortico-thalamic metabolic asymmetry is consistent with the focal neuropathological changes reported in CBGD brains. Our findings suggest that metabolic asymmetries detected with FDG/PET may support a diagnosis of CBGD in life. Images PMID:1744638

  18. Positron emission tomography in the diagnostic work-up of screening-detected lung nodules.

    PubMed

    Veronesi, Giulia; Travaini, Laura L; Maisonneuve, Patrick; Rampinelli, Cristiano; Bertolotti, Raffaella; Spaggiari, Lorenzo; Bellomi, Massimo; Paganelli, Giovanni

    2015-02-01

    Low-dose computed tomography (CT) screening for lung cancer can reduce lung cancer mortality, but overdiagnosis, false positives and invasive procedures for benign nodules are worrying. We evaluated the utility of positron emission tomography (PET)-CT in characterising indeterminate screening-detected lung nodules. 383 nodules, examined by PET-CT over the first 6 years of the COSMOS (Continuous Observation of Smoking Subjects) study to diagnose primary lung cancer, were reviewed and compared with pathological findings (surgically-treated patients) or follow-up (negative CT for ⩾2 years, considered negative); 196 nodules were malignant. The sensitivity, specificity and accuracy of PET-CT for differentially diagnosing malignant nodules were, respectively, 64%, 89% and 76% overall, and 82%, 92% and 88% for baseline-detected nodules. Performance was lower for nodules found at repeat annual scans, with sensitivity ranging from 22% for nonsolid to 79% for solid nodules (p=0.0001). Sensitivity (87%) and specificity (73%) were high for nodules ⩾15 mm, better (sensitivity 98%) for solid nodules ⩾15 mm. PET-CT was highly sensitive for the differential diagnosis of indeterminate nodules detected at baseline, nodules ⩾15 mm and solid nodules. Sensitivity was low for sub-solid nodules and nodules discovered after baseline for which other methods, e.g. volume doubling time, should be used.

  19. A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties

    NASA Astrophysics Data System (ADS)

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-11-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the other hand, modulation mechanisms of the optical properties of a material exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to for the first time study whether ionizing radiation can produce modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately 5× {{10}-6} is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the detected event rate and average photon energy of the radiation source.

  20. Positron emission tomography imaging of tau pathology in progressive supranuclear palsy.

    PubMed

    Coakeley, Sarah; Cho, Sang Soo; Koshimori, Yuko; Rusjan, Pablo; Harris, Madeleine; Ghadery, Christine; Kim, Jinhee; Lang, Anthony E; Wilson, Alan; Houle, Sylvain; Strafella, Antonio P

    2016-01-01

    Progressive supranuclear palsy is a rare form of atypical Parkinsonism that differs neuropathologically from other parkinsonian disorders. While many parkinsonian disorders such as Parkinson's disease, Lewy body dementia, and multiple system atrophy are classified as synucleinopathies, progressive supranuclear palsy is coined a tauopathy due to the aggregation of pathological tau in the brain. [(18)F]AV-1451 (also known as [(18)F]-T807) is a positron emission tomography radiotracer that binds to paired helical filaments of tau in Alzheimer's disease. We investigated whether [(18)F]AV-1451 could be used as biomarker for the diagnosis and disease progression monitoring in progressive supranuclear palsy. Six progressive supranuclear palsy, six Parkinson's disease, and 10 age-matched healthy controls were recruited. An anatomical MRI and a 90-min PET scan, using [(18)F]AV-1451, were acquired from all participants. The standardized uptake value ratio from 60 to 90 min post-injection was calculated in each region of interest, using the cerebellar cortex as a reference region. No significant differences in standardized uptake value ratios were detected in our progressive supranuclear palsy group compared to the two control groups. [(18)F]AV-1451 may bind selectivity to the paired helical filaments in Alzheimer's disease, which differ from the straight conformation of tau filaments in progressive supranuclear palsy.

  1. Positron Emission Tomography Imaging of Tumor Cell Metabolism and Application to Therapy Response Monitoring

    PubMed Central

    Challapalli, Amarnath; Aboagye, Eric O.

    2016-01-01

    Cancer cells do reprogram their energy metabolism to enable several functions, such as generation of biomass including membrane biosynthesis, and overcoming bioenergetic and redox stress. In this article, we review both established and evolving radioprobes developed in association with positron emission tomography (PET) to detect tumor cell metabolism and effect of treatment. Measurement of enhanced tumor cell glycolysis using 2-deoxy-2-[18F]fluoro-D-glucose is well established in the clinic. Analogs of choline, including [11C]choline and various fluorinated derivatives are being tested in several cancer types clinically with PET. In addition to these, there is an evolving array of metabolic tracers for measuring intracellular transport of glutamine and other amino acids or for measuring glycogenesis, as well as probes used as surrogates for fatty acid synthesis or precursors for fatty acid oxidation. In addition to providing us with opportunities for examining the complex regulation of reprogramed energy metabolism in living subjects, the PET methods open up opportunities for monitoring pharmacological activity of new therapies that directly or indirectly inhibit tumor cell metabolism. PMID:26973812

  2. Cognitive processes and cerebral cortical fundi: findings from positron-emission tomography studies.

    PubMed

    Markowitsch, H J; Tulving, E

    1994-10-25

    Positron-emission tomography (PET) studies of regional cerebral blood flow have provided evidence relevant to localization of cognitive functions. The critical loci identified in these studies are typically described in terms of macroanatomically labeled cortical and subcortical regions. We report the results of a meta-analysis of localization of changes in blood flow, based on nearly 1000 cerebral cortical peaks of activity obtained from groups of subjects in 30 PET studies. The results showed that, on average, 47% of these peaks were localized within the fundus regions of cortical sulci. This is an unexpectedly high proportion because fundal regions compose < 8% of the cortical mantle. Further analysis suggested a coarse correlation between the extent of fundal activation observed in different studies and the estimated cognitive complexity of the tasks used in the studies. These findings are potentially interesting because (i) the preponderance of fundal activation has implications for the interpretation of the PET data, (ii) they suggest that cortical sulcal and fundal regions may play a distinctive role in higher cognitive processing, or (iii) both of the above.

  3. TOPICAL REVIEW: Biological imaging in radiation therapy: role of positron emission tomography

    NASA Astrophysics Data System (ADS)

    Nestle, Ursula; Weber, Wolfgang; Hentschel, Michael; Grosu, Anca-Ligia

    2009-01-01

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.

  4. FPGA-Based Front-End Electronics for Positron Emission Tomography.

    PubMed

    Haselman, Michael; Dewitt, Don; McDougald, Wendy; Lewellen, Thomas K; Miyaoka, Robert; Hauck, Scott

    2009-02-22

    Modern Field Programmable Gate Arrays (FPGAs) are capable of performing complex discrete signal processing algorithms with clock rates above 100MHz. This combined with FPGA's low expense, ease of use, and selected dedicated hardware make them an ideal technology for a data acquisition system for positron emission tomography (PET) scanners. Our laboratory is producing a high-resolution, small-animal PET scanner that utilizes FPGAs as the core of the front-end electronics. For this next generation scanner, functions that are typically performed in dedicated circuits, or offline, are being migrated to the FPGA. This will not only simplify the electronics, but the features of modern FPGAs can be utilizes to add significant signal processing power to produce higher resolution images. In this paper two such processes, sub-clock rate pulse timing and event localization, will be discussed in detail. We show that timing performed in the FPGA can achieve a resolution that is suitable for small-animal scanners, and will outperform the analog version given a low enough sampling period for the ADC. We will also show that the position of events in the scanner can be determined in real time using a statistical positioning based algorithm.

  5. Development of analog solid-state photo-detectors for Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Bisogni, Maria Giuseppina; Morrocchi, Matteo

    2016-02-01

    Solid-state photo-detectors are one of the main innovations of past century in the field of sensors. First produced in the early forties with the invention of the p-n junction in silicon and the study of its optical properties, photo-detectors received a major boost in the sixties when the p-i-n (PIN) photodiode was developed and successfully used in several applications. The development of devices with internal gain, avalanche photodiodes (APD) first and then Geiger-mode avalanche photodiodes, named single photon avalanche diode (SPAD), leads to a substantial improvement in sensitivity and allowed single photon detection. Later on, thousands of SPADs have been assembled in arrays of few millimeters squared (named SiPM, silicon photo-multiplier) with single photon resolution. The high internal gain of SiPMs, together with other features peculiar of the silicon technology like compactness, speed and compatibility with magnetic fields, promoted SiPMs as the principal photo-detector competitor of photomultipliers in many applications from radiation detection to medical imaging. This paper provides a review of the properties of analog solid-state photo-detectors. Particular emphasis is given to latest advances on Positron Emission Tomography instrumentation boosted by the adoption of the silicon photo-detectors as an alternative to photomultiplier tubes (PMTs). Special attention is dedicated to the SiPMs, which are playing a key role in the development of innovative scanners.

  6. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    PubMed

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  7. Positron Emission Tomography (PET) Quantification of GABAA Receptors in the Brain of Fragile X Patients.

    PubMed

    D'Hulst, Charlotte; Heulens, Inge; Van der Aa, Nathalie; Goffin, Karolien; Koole, Michel; Porke, Kathleen; Van De Velde, Marc; Rooms, Liesbeth; Van Paesschen, Wim; Van Esch, Hilde; Van Laere, Koen; Kooy, R Frank

    2015-01-01

    Over the last several years, evidence has accumulated that the GABAA receptor is compromised in animal models for fragile X syndrome (FXS), a common hereditary form of intellectual disability. In mouse and fly models, agonists of the GABAA receptor were able to rescue specific consequences of the fragile X mutation. Here, we imaged and quantified GABAA receptors in vivo in brain of fragile X patients using Positron Emission Topography (PET) and [11C]flumazenil, a known high-affinity and specific ligand for the benzodiazepine site of GABAA receptors. We measured regional GABAA receptor availability in 10 fragile X patients and 10 control subjects. We found a significant reduction of on average 10% in GABAA receptor binding potential throughout the brain in fragile X patients. In the thalamus, the brain region showing the largest difference, the GABAA receptor availability was even reduced with 17%. This is one of the first reports of a PET study of human fragile X brain and directly demonstrates that the GABAA receptor availability is reduced in fragile X patients. The study reinforces previous hypotheses that the GABAA receptor is a potential target for rational pharmacological treatment of fragile X syndrome.

  8. Clinical applications of positron emission tomography/computed tomography treatment planning.

    PubMed

    Macapinlac, Homer A

    2008-03-01

    Positron emission tomography/computed tomography (PET/CT) has provided an incremental dimension to the management of cancer patients by allowing the incorporation of important molecular images in radiotherapy treatment planning, ie, direct evaluation of tumor metabolism, cell proliferation, apoptosis, hypoxia, and angiogenesis. The CT component allows 4D imaging techniques, allowing improvements in the accuracy of treatment delivery by compensating for tumor/normal organ motion, improving PET quantification, and correcting PET and CT image misregistration. The combination of PET and CT in a single imaging system to obtain a fused anatomical and functional image data is now emerging as a promising tool in radiotherapy departments for improved delineation of tumor volumes and optimization of treatment plans. PET has the potential to improve radiotherapy planning by minimizing unnecessary irradiation of normal tissues and by reducing the risk of geographic miss. PET influences treatment planning in a high proportion of cases and therefore radiotherapy dose escalation without PET may be futile. This article examines the increasing role of hybrid PET/CT imaging techniques in process of improving treatment planning in oncology with emphasis on non small cell lung cancer.

  9. A fast rebinning algorithm for 3D positron emission tomography using John's equation

    NASA Astrophysics Data System (ADS)

    Defrise, Michel; Liu, Xuan

    1999-08-01

    Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.

  10. The value of positron emission tomography scanning in the detection of subclinical metastatic melanoma.

    PubMed

    Acland, K M; O'Doherty, M J; Russell-Jones, R

    2000-04-01

    We have undertaken a retrospective analysis of all positron emission tomography (PET) scans carried out at St Thomas' Hospital, London, since 1994 to establish the sensitivity and specificity of this radiologic technique in cutaneous malignant melanoma. In particular, we have identified those patients with primary cutaneous malignant melanoma in whom PET scanning revealed in-transit or regional spread to nodes and those patients with known regional spread in whom PET scanning revealed distant metastases. We defined our false-negative results as a negative scan result with positive histology or subsequent clinical progression of disease. False-positive results were defined as a suspect scan with negative histology or no subsequent progression of disease. PET scanning had an overall sensitivity of 78% and specificity of 87%; however, subset analysis (M. D. Anderson staging system) showed a sensitivity of 50% for stage I disease (34 patients and 35 scans) and 33% for stage II disease (9 patients and 9 scans) with specificities of 87% and 100%, respectively. For stage III disease (16 patients and 17 scans), PET showed a sensitivity of 93% and specificity of 50%. Overall, 35% of patients with true-positive scans had their disease restaged. We can conclude therefore that PET is valuable as a staging procedure in patients with known regional spread but is suboptimal in the prediction of outcome in stage I or stage II disease.

  11. Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) Correlation of Histopathology and MRI in Prion Disease.

    PubMed

    Mente, Karin P; O'Donnell, James K; Jones, Stephen E; Cohen, Mark L; Thompson, Nicolas R; Bizzi, Alberto; Gambetti, Pierluigi; Safar, Jiri G; Appleby, Brian S

    2017-01-01

    Creutzfeldt-Jakob disease (CJD) and other prion diseases are rapidly progressive spongiform encephalopathies that are invariably fatal. Clinical features and magnetic resonance imaging, electroencephalogram, and cerebrospinal fluid abnormalities may suggest prion disease, but a definitive diagnosis can only be made by means of neuropathologic examination. Fluorodeoxyglucose positron emission tomography (FDG-PET) is not routinely used to evaluate patients with suspected prion disease. This study includes 11 cases of definite prion disease in which FDG-PET scans were obtained. There were 8 sporadic CJD cases, 2 genetic CJD cases, and 1 fatal familial insomnia case. Automated FDG-PET analysis revealed parietal region hypometabolism in all cases. Surprisingly, limbic and mesolimbic hypermetabolism were also present in the majority of cases. When FDG-PET hypometabolism was compared with neuropathologic changes (neuronal loss, astrocytosis, spongiosis), hypometabolism was predictive of neuropathology in 80.6% of cortical regions versus 17.6% of subcortical regions. The odds of neuropathologic changes were 2.1 times higher in cortical regions than subcortical regions (P=0.0265). A similar discordance between cortical and subcortical regions was observed between FDG-PET hypometabolism and magnetic resonance imaging diffusion weighted imaging hyperintensity. This study shows that there may be a relationship between FDG-PET hypometabolism and neuropathology in cortical regions in prion disease but it is unlikely to be helpful for diagnosis.

  12. Binocular disparity discrimination in human cerebral cortex: functional anatomy by positron emission tomography.

    PubMed Central

    Gulyás, B; Roland, P E

    1994-01-01

    Neurobiological studies in higher primates indicate that the processing of stereoscopic information takes place at early levels in the visual cortex. To map the anatomical structures in the human brain participating in pure stereopsis based upon binocular disparity, we measured with positron emission tomography the changes in regional cerebral blood flow as an indicator of metabolic activity in 10 healthy young men during visual discrimination of binocular disparity. The data demonstrate that the discrimination of pure stereo-optic disparity information takes place in the polar striate cortex and the neighboring peri-striate cortices, as well as in the parietal lobe, the prefrontal cortex, and the cerebellum. The discrimination of stereoscopic depth is dependent on a network composed of multiple functional fields localized in occipital- and parietal-lobe visual areas as well as in the dorsolateral and mesial prefrontal cortex. The findings support the importance of coactivated occipitoparietal visual areas in the processing and analysis of binocular depth information in humans. Images PMID:8108394

  13. Modelling human drug abuse and addiction with dedicated small animal positron emission tomography.

    PubMed

    Dalley, Jeffrey W; Fryer, Tim D; Aigbirhio, Franklin I; Brichard, Laurent; Richards, Hugh K; Hong, Young T; Baron, Jean-Claude; Everitt, Barry J; Robbins, Trevor W

    2009-01-01

    Drug addiction is a chronically relapsing brain disorder, which causes substantial harm to the addicted individual and society as a whole. Despite considerable research we still do not understand why some people appear particularly disposed to drug abuse and addiction, nor do we understand how frequently co-morbid brain disorders such as depression and attention-deficit hyperactivity disorder (ADHD) contribute causally to the emergence of addiction-like behaviour. In recent years positron emission tomography (PET) has come of age as a translational neuroimaging technique in the study of drug addiction, ADHD and other psychopathological states in humans. PET provides unparalleled quantitative assessment of the spatial distribution of radiolabelled molecules in the brain and because it is non-invasive permits longitudinal assessment of physiological parameters such as binding potential in the same subject over extended periods of time. However, whilst there are a burgeoning number of human PET experiments in ADHD and drug addiction there is presently a paucity of PET imaging studies in animals despite enormous advances in our understanding of the neurobiology of these disorders based on sophisticated animal models. This article highlights recent examples of successful cross-species convergence of findings from PET studies in the context of drug addiction and ADHD and identifies how small animal PET can more effectively be used to model complex psychiatric disorders involving at their core impaired behavioural self-control.

  14. Positron emission tomography to assess hypoxia and perfusion in lung cancer

    PubMed Central

    Verwer, Eline E; Boellaard, Ronald; van der Veldt, Astrid AM

    2014-01-01

    In lung cancer, tumor hypoxia is a characteristic feature, which is associated with a poor prognosis and resistance to both radiation therapy and chemotherapy. As the development of tumor hypoxia is associated with decreased perfusion, perfusion measurements provide more insight into the relation between hypoxia and perfusion in malignant tumors. Positron emission tomography (PET) is a highly sensitive nuclear imaging technique that is suited for non-invasive in vivo monitoring of dynamic processes including hypoxia and its associated parameter perfusion. The PET technique enables quantitative assessment of hypoxia and perfusion in tumors. To this end, consecutive PET scans can be performed in one scan session. Using different hypoxia tracers, PET imaging may provide insight into the prognostic significance of hypoxia and perfusion in lung cancer. In addition, PET studies may play an important role in various stages of personalized medicine, as these may help to select patients for specific treatments including radiation therapy, hypoxia modifying therapies, and antiangiogenic strategies. In addition, specific PET tracers can be applied for monitoring therapy. The present review provides an overview of the clinical applications of PET to measure hypoxia and perfusion in lung cancer. Available PET tracers and their characteristics as well as the applications of combined hypoxia and perfusion PET imaging are discussed. PMID:25493221

  15. Magnetic resonance imaging and positron emission tomography in the diagnosis of neurodegenerative dementias

    PubMed Central

    Del Sole, Angelo; Malaspina, Simona; Biasina, Alberto Magenta

    2016-01-01

    Summary Neuroimaging, both with magnetic resonance imaging (MRI) and positron emission tomography (PET), has gained a pivotal role in the diagnosis of primary neurodegenerative diseases. These two techniques are used as biomarkers of both pathology and progression of Alzheimer’s disease (AD) and to differentiate AD from other neurodegenerative diseases. MRI is able to identify structural changes including patterns of atrophy characterizing neurodegenerative diseases, and to distinguish these from other causes of cognitive impairment, e.g. infarcts, space-occupying lesions and hydrocephalus. PET is widely used to identify regional patterns of glucose utilization, since distinct patterns of distribution of cerebral glucose metabolism are related to different subtypes of neurodegenerative dementia. The use of PET in mild cognitive impairment, though controversial, is deemed helpful for predicting conversion to dementia and the dementia clinical subtype. Recently, new radiopharmaceuticals for the in vivo imaging of amyloid burden have been licensed and more tracers are being developed for the assessment of tauopathies and inflammatory processes, which may underlie the onset of the amyloid cascade. At present, the cerebral amyloid burden, imaged with PET, may help to exclude the presence of AD as well as forecast its possible onset. Finally PET imaging may be particularly useful in ongoing clinical trials for the development of dementia treatments. In the near future, the use of the above methods, in accordance with specific guidelines, along with the use of effective treatments will likely lead to more timely and successful treatment of neurodegenerative dementias. PMID:28072381

  16. Dynamic positron emission tomography image restoration via a kinetics-induced bilateral filter.

    PubMed

    Bian, Zhaoying; Huang, Jing; Ma, Jianhua; Lu, Lijun; Niu, Shanzhou; Zeng, Dong; Feng, Qianjin; Chen, Wufan

    2014-01-01

    Dynamic positron emission tomography (PET) imaging is a powerful tool that provides useful quantitative information on physiological and biochemical processes. However, low signal-to-noise ratio in short dynamic frames makes accurate kinetic parameter estimation from noisy voxel-wise time activity curves (TAC) a challenging task. To address this problem, several spatial filters have been investigated to reduce the noise of each frame with noticeable gains. These filters include the Gaussian filter, bilateral filter, and wavelet-based filter. These filters usually consider only the local properties of each frame without exploring potential kinetic information from entire frames. Thus, in this work, to improve PET parametric imaging accuracy, we present a kinetics-induced bilateral filter (KIBF) to reduce the noise of dynamic image frames by incorporating the similarity between the voxel-wise TACs using the framework of bilateral filter. The aim of the proposed KIBF algorithm is to reduce the noise in homogeneous areas while preserving the distinct kinetics of regions of interest. Experimental results on digital brain phantom and in vivo rat study with typical (18)F-FDG kinetics have shown that the present KIBF algorithm can achieve notable gains over other existing algorithms in terms of quantitative accuracy measures and visual inspection.

  17. Positron emission tomographic scan investigations of Huntington's disease: cerebral metabolic correlates of cognitive function

    SciTech Connect

    Berent, S.; Giordani, B.; Lehtinen, S.; Markel, D.; Penney, J.B.; Buchtel, H.A.; Starosta-Rubinstein, S.; Hichwa, R.; Young, A.B.

    1988-06-01

    Fifteen drug-free patients with early to mid-stage Huntington's disease (HD) were evaluated with positron emission tomographic (PET) scans of /sup 18/F-2-fluoro-2-deoxy-D-glucose uptake and quantitative measures of neurological function, learning, memory, and general intelligence. In comparison with a group of normal volunteers, the HD patients showed lower metabolism in both caudate (p less than 0.001) and putamen (p less than 0.001) on PET scans. A significant and positive relationship was found between neuropsychological measures of verbal learning and memory and caudate metabolism in the patient group but not in the normal group. Visual-spatial learning did not reflect a similar pattern, but performance intelligence quotient was positively related to both caudate and putamen metabolism in the HD group. Vocabulary level was unrelated to either brain structure. Discussion focuses on these and other observed brain-behavior relationships and on the implications of these findings for general behaviors such as those involved in coping and adaptation.

  18. Evoked Potentials and Neuropsychological Tests Validate Positron Emission Topography (PET) Brain Metabolism in Cognitively Impaired Patients

    PubMed Central

    Braverman, Eric R.; Blum, Kenneth; Damle, Uma J.; Kerner, Mallory; Dushaj, Kristina; Oscar-Berman, Marlene

    2013-01-01

    Fluorodeoxyglucose (FDG) Positron Emission Topography (PET) brain hypometabolism (HM) correlates with diminished cognitive capacity and risk of developing dementia. However, because clinical utility of PET is limited by cost, we sought to determine whether a less costly electrophysiological measure, the P300 evoked potential, in combination with neuropsychological test performance, would validate PET HM in neuropsychiatric patients. We found that patients with amnestic and non-amnestic cognitive impairment and HM (n = 43) evidenced significantly reduced P300 amplitudes, delayed latencies, and neuropsychological deficits, compared to patients with normal brain metabolism (NM; n = 187). Data from patients with missing cognitive test scores (n = 57) were removed from the final sample, and logistic regression modeling was performed on the modified sample (n = 173, p = .000004). The logistic regression modeling, based on P300 and neuropsychological measures, was used to validate membership in the HM vs. NM groups. It showed classification validation in 13/25 HM subjects (52.0%) and in 125/148 NM subjects (84.5%), correlating with total classification accuracy of 79.8%. In this paper, abnormal P300 evoked potentials coupled with cognitive test impairment validates brain metabolism and mild/moderate cognitive impairment (MCI). To this end, we cautiously propose incorporating electrophysiological and neuropsychological assessments as cost-effective brain metabolism and MCI indicators in primary care. Final interpretation of these results must await required additional studies confirming these interesting results. PMID:23526928

  19. Metabolizer in vivo of fullerenes and metallofullerenes by positron emission tomography

    NASA Astrophysics Data System (ADS)

    Li, Juan; Yang, Wenjiang; Cui, Rongli; Wang, Dongliang; Chang, Yanan; Gu, Weihong; Yin, Wenyan; Bai, Xue; Chen, Kui; Xia, Lin; Geng, Huan; Xing, Gengmei

    2016-04-01

    Fullerenes (C60) and metallofullerenes (Gd@C82) have similar chemical structure, but the bio-effects of both fullerene-based materials are distinct in vivo. Tracking organic carbon-based materials such as C60 and Gd@C82 is difficult in vivo due to the high content of carbon element in the living tissues themselves. In this study, the biodistribution and metabolism of fullerenes (C60 and Gd@C82) radiolabeled with 64Cu were observed by positron emission tomography (PET). 64Cu-C60 and 64Cu-Gd@C82 were prepared using 1, 4, 7, 10-tetrakis (carbamoylmethyl)-1, 4, 7, 10-tetra-azacyclodo-decanes grafted on carbon cages as a chelator for 64Cu, and were obtained rapidly with high radiochemical yield (≥90%). The new radio-conjugates were evaluated in vivo in the normal mouse model and tissue distribution by small animal PET/CT imaging and histology was carried out. The PET imaging, the biodistribution and the excretion of C60 and Gd@C82 indicated that C60 samples have higher blood retention and lower renal clearance than the Gd@C82 samples in vivo and suggested that the differences in metabolism and distribution in vivo were caused by the structural differences of the groups on the fullerene cages though there is chemical similarity between C60 and Gd@C82.

  20. Assessment of Cancer-Associated Biomarkers by Positron Emission Tomography: Advances and Challenges

    PubMed Central

    Collier, T. Lee; Lecomte, Roger; McCarthy, Timothy J.; Meikle, Steve; Ruth, Thomas J.; Scopinaro, Francesco; Signore, Alberto; Van Brocklin, Henry; Van de Wiele, Christophe; Waterhouse, Rikki N.

    2002-01-01

    Positron emission tomography (PET) provides a powerful means to non-invasively image and quantify protein expression and biochemical changes in living subjects at nano- and picomolar levels. As the field of molecular imaging develops, and as advances in the biochemistry, pharmacology, therapeutics, and molecular biology of disease are made, there is a corresponding increase in the number of clinically relevant, novel disease-associated biomarkers that are brought to the attention of those developing imaging probes for PET. In addition, due to the high specificity of the PET radiotracers being developed, there is a demand for PET cameras with higher sensitivity and resolution. This manuscript reviews advances over the past five years in clinical and pre-clinical PET instrumentation and in new PET probes and imaging methods associated with the latest trends in the molecular imaging of cancer. Included in the PET tracer review is a description of new radioligands for steroid receptors, growth factor receptors, receptor tyrosine kinases, sigma receptors, tumor-associated enzymes, gene reporter probes, markers for tumor hypoxia and metabolism, and sites associated with angiogenesis and cellular proliferation. The use of PET imaging in drug development, including the monitoring of cancer chemotherapy, also is discussed. PMID:14646039

  1. Future imaging of atherosclerosis: molecular imaging of coronary atherosclerosis with 18F positron emission tomography

    PubMed Central

    Psaltis, Peter J.

    2016-01-01

    Atherosclerosis is characterized by the formation of complex atheroma lesions (plaques) in arteries that pose risk by their flow-limiting nature and propensity for rupture and thrombotic occlusion. It develops in the context of disturbances to lipid metabolism and immune response, with inflammation underpinning all stages of plaque formation, progression and rupture. As the primary disease process responsible for myocardial infarction, stroke and peripheral vascular disease, atherosclerosis is a leading cause of morbidity and mortality on a global scale. A precise understanding of its pathogenic mechanisms is therefore critically important. Integral to this is the role of vascular wall imaging. Over recent years, the rapidly evolving field of molecular imaging has begun to revolutionize our ability to image beyond just the anatomical substrate of vascular disease, and more dynamically assess its pathobiology. Nuclear imaging by positron emission tomography (PET) can target specific molecular and biological pathways involved in atherosclerosis, with the application of 18Fluoride PET imaging being widely studied for its potential to identify plaques that are vulnerable or high risk. In this review, we discuss the emergence of 18Fluoride PET as a promising modality for the assessment of coronary atherosclerosis, focusing on the strengths and limitations of the two main radionuclide tracers that have been investigated to date: 2-deoxy-2-(18F)fluoro-D-glucose (18F-FDG) and sodium 18F-fluoride (18F-NaF). PMID:27500093

  2. INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy.

    PubMed

    Bisogni, Maria Giuseppina; Attili, Andrea; Battistoni, Giuseppe; Belcari, Nicola; Camarlinghi, Niccolo'; Cerello, Piergiorgio; Coli, Silvia; Del Guerra, Alberto; Ferrari, Alfredo; Ferrero, Veronica; Fiorina, Elisa; Giraudo, Giuseppe; Kostara, Eleftheria; Morrocchi, Matteo; Pennazio, Francesco; Peroni, Cristiana; Piliero, Maria Antonietta; Pirrone, Giovanni; Rivetti, Angelo; Rolo, Manuel D; Rosso, Valeria; Sala, Paola; Sportelli, Giancarlo; Wheadon, Richard

    2017-01-01

    The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. In 2013, the Innovative Solutions for Dosimetry in Hadrontherapy (INSIDE) collaboration proposed an innovative bimodal imaging concept that combines an in-beam PET scanner with a tracking system for charged particle imaging. This paper presents the general architecture of the INSIDE project but focuses on the in-beam PET scanner that has been designed to reconstruct the particles range with millimetric resolution within a fraction of the dose delivered in a treatment of head and neck tumors. The in-beam PET scanner has been recently installed at the Italian National Center of Oncologic Hadrontherapy (CNAO) in Pavia, Italy, and the commissioning phase has just started. The results of the first beam test with clinical proton beams on phantoms clearly show the capability of the in-beam PET to operate during the irradiation delivery and to reconstruct on-line the beam-induced activity map. The accuracy in the activity distal fall-off determination is millimetric for therapeutic doses.

  3. The role of positron emission tomography in the detection of pancreatic disease

    SciTech Connect

    Syrota, A.; Duquesnoy, N.; Paraf, A.; Kellershohn, C.

    1982-04-01

    Positron emission tomography (PET) was used to assess possible pancreatic disease in 100 patients. Following injection of 10-15 mCi (370-740 MBq) of /sup 11/C-L-methionine, 4-12 transverse sections 2 cm thick were obtained. In 85 patients with a definite diagnosis (45 normal, 9 acute pancreatitis, 18 chronic pancreatitis, and 13 cancer), PET showed a sensitivity of 85.0%, a specificity of 97.8%, and an accuracy of 91.8%, higher than with transmission computed tomography (CT) or ultrasonography, despite relatively low spatial resolution; this can be explained by the fact that exocrine pancreatic function was altered prior to morphological change. In 22 normal subjects, 0.011 +/- 0.003% (mean +/- S.D.) of injected /sup 11/C was found in 1 ml of liver tissue and 0.015 +/- 0.005% in 1 ml of pancreatic tissue; the pancreas-to-liver concentration ratio was 1.3 +/- 0.4. Hepatic /sup 11/C concentration was identical in the four groups of patients. Pancreatic uptake of /sup 11/C-L-methionine was significantly lower in patients with chronic pancreatitis (n = 13) and pancreatic carcinoma (n = 10) (p <0.001); however, it was not possible to distinguish cancer from chronic pancreatitis because the same functional alteration occurred in both.

  4. Imaging of the pancreas using dynamic positron emission tomography with N-13 ammonia

    SciTech Connect

    Hayashi, N.; Tamaki, N.; Yonekura, Y.; Adachi, H.; Senda, M.; Saji, H.; Torizuka, K.

    1985-05-01

    This study was undertaken to develop a new imaging technique of the pancreas. Dynamic positron emission tomography (PET) was performed in 3 normal volunteers, 9 patient without the evidence of pancreatic diseases, 2 patients with adenocarcinoma of the pancreatic head and one patient with islet cell carcinoma. Immediately after the intravenous injection of 10-20mCi of N-13 ammonia, data were obtained every 150 seconds for 30 minutes using a multi-slice whole-body PET scanner. In two cases of adenocarcinoma, the pancreas was not imaged, probably because the nontumorous portion of the pancreas was also suffered from severe pancreatitis due to the duct obstruction at the pancreatic head. In the case with islet cell carcinoma, the radionuclide was accumulated in the tumor and pancreas similarly. Thus, both of them were visualized but not separated. The central necrosis of the tumor showed poor radioactivity. The mechanism of the radionuclide accumulation in the pancreas is not well understood. However, the authors also studied the biodistribution of N-13 ammonia in mice and confirmed that there is an early and high accumulation of the radionuclide in the murine pancreas. These preliminary results of this paper suggest that the dynamic PET study may be useful for the imaging of the pancreas as well as for the further study of the blood supply and metabolism of the pancreas.

  5. The role of positron emission tomography in the detection of pancreatic disease

    SciTech Connect

    Syrota, A.; Duquesnoy, N.; Paraf, A.; Kellershohn, C.

    1982-04-01

    Positron emission tomography (PET) was used to assess possible pancreatic disease in 100 patients. Following injection of 10-15 mCi (370-740 MBq) of 11C-L-methionine, 4-12 transverse sections 2 cm thick were obtained. In 85 patients with a definite diagnosis (45 normal, 9 acute pancreatitis, 18 chronic pancreatitis, and 13 cancer), PET showed a sensitivity of 85.0%, a specificity of 97.8%, and an accuracy of 91.8%, higher than with transmission computed tomography (CT) or ultrasonography, despite relatively low spatial resolution; this can be explained by the fact that exocrine pancreatic function was altered prior to morphological change. In 22 normal subjects, 0.011 +/- 0.003% (mean +/- S.D). of injected 11C was found in 1 ml of liver tissue and 0.015 +/- 0.005% in 1 ml of pancreatic tissue; the pancreas-to-liver concentration ratio was 1.3 +/- 0.4. Hepatic 11C concentration was identical in the four groups of patients. Pancreatic uptake of 11C-L-methionine was significantly lower in patients with chronic pancreatitis (n . 13) and pancreatic carcinoma (n . 10) (p less than 0.001); however, it was not possible to distinguish cancer from chronic pancreatitis because the same functional alteration occurred in both.

  6. Speech disorders in olivopontocerebellar atrophy correlate with positron emission tomography findings

    SciTech Connect

    Kluin, K.J.; Gilman, S.; Markel, D.S.; Koeppe, R.A.; Rosenthal, G.; Junck, L.

    1988-06-01

    We compared the severity of ataxic and spastic dysarthria with local cerebral metabolic rates for glucose (lCMRGlc) in 30 patients with olivopontocerebellar atrophy (OPCA). Perceptual analysis was used to examine the speech disorders, and rating scales were devised to quantitate the degree of ataxia and spasticity in the speech of each patient. lCMRGlc was measured with /sup 18/F-2-fluoro-2-deoxy-D-glucose and positron emission tomography (PET). PET studies revealed marked hypometabolism in the cerebellar hemispheres, cerebellar vermis, and brainstem of OPCA patients compared with 30 control subjects. With data normalized to the cerebral cortex, a significant inverse correlation was found between the severity of ataxia in speech and the lCMRGlc within the cerebellar vermis, cerebellar hemispheres, and brainstem, but not within the thalamus. No significant correlation was found between the severity of spasticity in speech and lCMRGlc in any of these structures. The findings support the view that the severity of ataxia in speech in OPCA is related to the functional activity of the cerebellum and its connections in the brainstem.

  7. Molecular imaging of neuroinflammation in preclinical rodent models using positron emission tomography.

    PubMed

    Gargiulo, Sara; Coda, Anna R; Panico, Mariarosaria; Gramanzini, Matteo; Moresco, Rosa M; Chalon, Sylvie; Pappatà, Sabina

    2017-03-01

    Neuroinflammation (NI) is an adaptive response to different noxious stimuli, involving microglia, astrocytes and peripheral immune cells. NI is a hallmark of several acute and chronic diseases of central nervous system (CNS) and contributes to both damage and repair of CNS tissue. Interventional or genetically modified rodent models mimicking human neuropathologies may provide valuable insights on basic mechanisms of NI, but also for improving the development of new diagnostic and therapeutic strategies. Preclinical positron emission tomography (PET) allows to investigate noninvasively the inflammatory response in CNS of rodent models at a molecular level, validating innovative probes for early diagnosis, and characterizing the time course of neuroinflammatory changes and their relationship with disease progression, as well as the effects of experimental treatments with high translational potential. In particular, recent efforts of preclinical PET field are intended to develop specific and selective radiotracers that target the activation of innate immune system in CNS. Here, we have reviewed the state of art for PET in relevant rodent models of acute and chronic neuropathologies associated with NI, with particular regard on imaging of activated microglia and astrocytes.

  8. Imaging Multimodalities for Dissecting Alzheimer's Disease: Advanced Technologies of Positron Emission Tomography and Fluorescence Imaging

    PubMed Central

    Shimojo, Masafumi; Higuchi, Makoto; Suhara, Tetsuya; Sahara, Naruhiko

    2015-01-01

    The rapid progress in advanced imaging technologies has expanded our toolbox for monitoring a variety of biological aspects in living subjects including human. In vivo radiological imaging using small chemical tracers, such as with positron emission tomography, represents an especially vital breakthrough in the efforts to improve our understanding of the complicated cascade of neurodegenerative disorders including Alzheimer's disease (AD), and it has provided the most reliable visible biomarkers for enabling clinical diagnosis. At the same time, in combination with genetically modified animal model systems, the most recent innovation of fluorescence imaging is helping establish diverse applications in basic neuroscience research, from single-molecule analysis to animal behavior manipulation, suggesting the potential utility of fluorescence technology for dissecting the detailed molecular-based consequence of AD pathophysiology. In this review, our primary focus is on a current update of PET radiotracers and fluorescence indicators beneficial for understanding the AD cascade, and discussion of the utility and pitfalls of those imaging modalities for future translational research applications. We will also highlight current cutting-edge genetic approaches and discuss how to integrate individual technologies for further potential innovations. PMID:26733795

  9. Positron emission tomography / computerized tomography evaluation of primary Hodgkin's disease of liver.

    PubMed

    Gota, V S; Purandare, N C; Gujral, S; Shah, S; Nair, R; Rangarajan, V

    2009-01-01

    Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.

  10. The role of pallidal serotonergic function in Parkinson's disease dyskinesias: a positron emission tomography study.

    PubMed

    Smith, Ruben; Wu, Kit; Hart, Thomas; Loane, Clare; Brooks, David J; Björklund, Anders; Odin, Per; Piccini, Paola; Politis, Marios

    2015-04-01

    We have investigated the role of globus pallidus (GP) serotonergic terminals in the development of levodopa-induced dyskinesias (LIDs) in Parkinson's disease (PD). We studied 12 PD patients without LIDs, 12 PD patients with LIDs, and 12 healthy control subjects. We used (11)C-DASB positron emission tomography (PET), a marker of serotonin transporter availability, and (11)C-raclopride PET to measure changes in synaptic dopamine levels following levodopa administration. PD patients without LIDs showed a significant reduction of GP serotonin transporter binding compared with healthy controls although this was within the normal range in PD patients with LIDs. Levels of GP serotonin transporter binding correlated positively with severity of dyskinesias. (11)C-raclopride PET detected a significant rise in GP synaptic dopamine levels of patients with LIDs after a levodopa challenge but not in patients with a stable response. Our findings indicate that LIDs in PD are associated with higher GP serotonergic function. This increased serotonin function may result in further dysregulation of thalamocortical signals and so promote the expression of dyskinesias.

  11. Mycosis fungoides staged by 18F-flurodeoxyglucose positron emission tomography/computed tomography

    PubMed Central

    Xu, Lu; Pang, Hua; Zhu, Jin; Chen, Xi; Guan, Lili; Wang, Jie; Chen, Jing; Liu, Ying

    2016-01-01

    Abstract Introduction: Mycosis fungoides is a kind of malignant lymphoma arising from T cells, but primarily occurs in skin, and it is the most common type of cutaneous lymphoma. Mycosis fungoides (MF) is a rare non-Hodgkin lymphoma but the most common type of primary cutaneous T-cell lymphomas. Because of unknown etiology and mechanism, and lack of typical clinical and histophysiological manifestations, the final diagnosis of MF is currently dependent on pathology and immunohistochemistry. Subsequently, tumor staging is very important. Different approaches would be taken according to varying degrees of cutaneous and extracutaneous lesions. Computed tomography (CT) scan has been chosen to stage tumors customarily. However, CT could only provide morphological information and analyze lymphadenopathy by the size criteria. 18F-flurodeoxyglucose positron emission tomography/computed tomography (PET/CT) could provide morphological information and metabolic conditions simultaneously, which is helpful to locate and stage lesion. Conclusion: 18F-flurodeoxyglucose PET/CT could identify cutaneous and extracutaneous lesions in patients with MF. It could provide the range of lesions and biopsy target. PMID:27828842

  12. Regional Cerebral Glucose Metabolism in Novelty Seeking and Antisocial Personality: A Positron Emission Tomography Study

    PubMed Central

    Park, So Hyeon; Park, Hyun Soo

    2016-01-01

    Novelty seeking (NS) and antisocial personality (ASP) are commonly exhibited by those who suffer from addictions, such as substance abuse. NS has been suggested to be a fundamental aspect of ASP. To investigate the neurobiological substrate of NS and ASP, we tested the relationship between regional cerebral glucose metabolism and the level of NS, determining the differences between individuals with and without ASP. Seventy-two healthy adults (43 males, mean age±SD=38.8±16.6 years, range=20~70 years; 29 females, 44.2±20.1 years, range=19~72 years) underwent resting-state brain positron emission tomography (PET) 40 minutes after 18F-fluorodeoxyglucose (FDG) injection. Within 10 days of the FDG PET study, participants completed Cloninger's 240-item Temperament and Character Inventory (TCI) to determine NS scores. Participants with and without ASP were grouped according to their TCI profiles. Statistical parametric mapping analysis was performed using the FDG PET and TCI profile data. NS scores positively correlated with metabolism in the left anterior cingulate gyrus and the insula on both sides of the brain and negatively correlated with metabolism in the right pallidum and putamen. Participants with ASP showed differences in cerebral glucose metabolism across various cortical and subcortical regions, mainly in the frontal and prefrontal areas. These data demonstrate altered regional cerebral glucose metabolism in individuals with NS and ASP and inform our understanding of the neurobiological substrates of problematic behaviors and personality disorders. PMID:27574485

  13. Low background high efficiency radiocesium detection system based on positron emission tomography technology

    SciTech Connect

    Yamamoto, Seiichi; Ogata, Yoshimune

    2013-09-15

    After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

  14. Preclinical positron emission tomography scanner based on a monolithic annulus of scintillator: initial design study.

    PubMed

    Stolin, Alexander V; Martone, Peter F; Jaliparthi, Gangadhar; Raylman, Raymond R

    2017-01-01

    Positron emission tomography (PET) scanners designed for imaging of small animals have transformed translational research by reducing the necessity to invasively monitor physiology and disease progression. Virtually all of these scanners are based on the use of pixelated detector modules arranged in rings. This design, while generally successful, has some limitations. Specifically, use of discrete detector modules to construct PET scanners reduces detection sensitivity and can introduce artifacts in reconstructed images, requiring the use of correction methods. To address these challenges, and facilitate measurement of photon depth-of-interaction in the detector, we investigated a small animal PET scanner (called AnnPET) based on a monolithic annulus of scintillator. The scanner was created by placing 12 flat facets around the outer surface of the scintillator to accommodate placement of silicon photomultiplier arrays. Its performance characteristics were explored using Monte Carlo simulations and sections of the NEMA NU4-2008 protocol. Results from this study revealed that AnnPET's reconstructed spatial resolution is predicted to be [Formula: see text] full width at half maximum in the radial, tangential, and axial directions. Peak detection sensitivity is predicted to be 10.1%. Images of simulated phantoms (mini-hot rod and mouse whole body) yielded promising results, indicating the potential of this system for enhancing PET imaging of small animals.

  15. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    SciTech Connect

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-09-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients.

  16. Positron emission tomography--examination of chemical transmission in the living human brain. Development of radioligands.

    PubMed

    Farde, L; Hall, H

    1992-02-01

    The imaging technique Positron Emission Tomography (PET) allows examination of chemical neurotransmission in brain. Of key importance for PET-research on neuroreceptors is the development of suitable radiolabelled tracers (ligands). This paper illustrates the multidisciplinary research activities necessary for ligand development. The selective D1- and D2-dopamine receptor antagonists SCH 23390 and raclopride (CAS 84225-95-6), respectively, were labelled with [3H] and characterized in biochemical studies in vitro on human brain homogenates and in autoradiographic studies on cryosections from human hemispheres. The experimental information was used to interpret and support the PET-findings with [11C]-labelled SCH 23390 and raclopride in vivo in humans. In conclusion, these ligands can be used to quantitatively examine dopamine receptors in the human basal ganglia in vivo. An applied study for PET-determination of D1- and D2-dopamine receptor occupancy during antipsychotic drug treatment indicates that the D2-dopamine receptor and possibly also the D1-dopamine receptor are targets for neuroleptic drug action.

  17. In vivo measurement of dopamine receptors in pituitary adenomas using positron emission tomography.

    PubMed

    Muhr, C; Bergström, M; Lundberg, P O; Bergström, K; Långström, B

    1986-01-01

    Patients with pituitary adenomas were examined with positron emission tomography (PET) with the administration of the 11C-labelled dopamine-D2 antagonists N-methylspiperone and raclopride. The studies were repeated after protection of the D2-receptors with Haloperidol to enable a separation of specific and unspecific receptor binding. The receptor binding was evaluated by visual inspection and with the application of a kinetic model. The results showed marked specific dopamine-D2 receptor binding in the prolactinomas and minimal or no such binding in the hormonally inactive adenomas. The two tracers 11C-raclopride and 11C-N-methylspiperone showed qualitatively the same result although raclopride resulted in a higher tumor to normal brain ratio. In conclusion, PET is a valuable complement to other radiologic techniques like computed tomography and magnetic resonance imaging in the evaluation of pituitary adenomas. An assessment of the dopamine-D2 receptors in the adenomas has a direct influence on the choice of treatment because adenomas with high amounts of receptors are in most cases effectively treated with dopamine agonists like bromocriptine.

  18. A New Positron Emission Tomography (PET) Radioligand for Imaging Sigma-1 Receptors in Living Subjects

    PubMed Central

    Zavaleta, Cristina L.; Nielsen, Carsten H.; Mesangeau, Christophe; Vuppala, Pradeep K.; Chan, Carmel; Avery, Bonnie A.; Fishback, James A.; Matsumoto, Rae R.; Gambhir, Sanjiv S.; McCurdy, Christopher R.; Chin, Frederick T.

    2014-01-01

    Sigma-1 receptor (S1R) radioligands have the potential to detect and monitor various neurological diseases. Herein we report the synthesis, radiofluorination and evaluation of a new S1R ligand 6-(3-fluoropropyl)-3-(2-(azepan-1-yl)ethyl)benzo[d]thiazol-2(3H)-one ([18F]FTC-146, [18F]13). [18F]13 was synthesized by nucleophilic fluorination, affording a product with >99% radiochemical purity (RCP) and specific activity (SA) of 2.6 ± 1.2 Ci/Amol (n = 13) at end of synthesis (EOS). Positron emission tomography (PET) and ex vivo autoradiography studies of [18F]13 in mice showed high uptake of the radioligand in S1R rich regions of the brain. Pre treatment with 1 mg/kg haloperidol (2), non radioactive 13, or BD1047 (18) reduced the binding of [18F]13 in the brain at 60 min by 80%, 82% and 81% respectively, suggesting that [18F]13 accumulation in mouse brain represents specific binding to S1Rs. These results indicate that [18F]13 is a promising candidate radiotracer for further evaluation as a tool for studying S1Rs in living subjects. PMID:22853801

  19. Caged [(18)F]FDG Glycosylamines for Imaging Acidic Tumor Microenvironments Using Positron Emission Tomography.

    PubMed

    Flavell, Robert R; Truillet, Charles; Regan, Melanie K; Ganguly, Tanushree; Blecha, Joseph E; Kurhanewicz, John; VanBrocklin, Henry F; Keshari, Kayvan R; Chang, Christopher J; Evans, Michael J; Wilson, David M

    2016-01-20

    Solid tumors are hypoxic with altered metabolism, resulting in secretion of acids into the extracellular matrix and lower relative pH, a feature associated with local invasion and metastasis. Therapeutic and diagnostic agents responsive to this microenvironment may improve tumor-specific delivery. Therefore, we pursued a general strategy whereby caged small-molecule drugs or imaging agents liberate their parent compounds in regions of low interstitial pH. In this manuscript, we present a new acid-labile prodrug method based on the glycosylamine linkage, and its application to a class of positron emission tomography (PET) imaging tracers, termed [(18)F]FDG amines. [(18)F]FDG amines operate via a proposed two-step mechanism, in which an acid-labile precursor decomposes to form the common radiotracer 2-deoxy-2-[(18)F]fluoro-d-glucose, which is subsequently accumulated by glucose avid cells. The rate of decomposition of [(18)F]FDG amines is tunable in a systematic fashion, tracking the pKa of the parent amine. In vivo, a 4-phenylbenzylamine [(18)F]FDG amine congener showed greater relative accumulation in tumors over benign tissue, which could be attenuated upon tumor alkalinization using previously validated models, including sodium bicarbonate treatment, or overexpression of carbonic anhydrase. This new class of PET tracer represents a viable approach for imaging acidic interstitial pH with potential for clinical translation.

  20. Utility of positron emission tomography-magnetic resonance imaging in musculoskeletal imaging

    PubMed Central

    Chaudhry, Ammar A; Gul, Maryam; Gould, Elaine; Teng, Mathew; Baker, Kevin; Matthews, Robert

    2016-01-01

    Differentiation between neoplastic and nonneoplastic conditions magnetic resonance imaging (MRI) has established itself as one of the key clinical tools in evaluation of musculoskeletal pathology. However, MRI still has several key limitations which require supplemental information from additional modalities to complete evaluation of various disorders. This has led to the development hybrid positron emission tomography (PET)-MRI which is rapidly evolving to address key clinical questions by using the morphological strengths of MRI and functional information of PET imaging. In this article, we aim to review physical principles and techniques of PET-MRI and discuss clinical utility of functional information obtained from PET imaging and structural information obtained from MRI imaging for the evaluation of musculoskeletal pathology. More specifically, this review highlights the role of PET-MRI in musculoskeletal oncology including initial diagnosis and staging, treatment planning and post-treatment follow-up. Also we will review utility of PET-MRI in evaluating musculoskeletal infections (especially in the immunocompromised and diabetics) and inflammatory condition. Additionally, common pitfalls of PET-MRI will be addressed. PMID:27027320

  1. F-18 Fluorodeoxyglucose Positron Emission Tomography study of Impaired Emotion Processing in First Episode Schizophrenia

    PubMed Central

    Choudhary, Mona; Kumar, Arvind; Tripathi, Madhavi; Bhatia, Triptish; Shivakumar, Venkataram; Beniwal, Ram Pratap; Gur, Ruben C.; Gur, Raquel E.; Nimgaonkar, Vishwajit L.

    2015-01-01

    Background Schizophrenia cases have consistently shown to have behavioural and neurofunctional abnormalities but studies during early course are scarce. The present work assesses the performance of acute first episode schizophrenia cases on correlation of a facial emotion perception task with brain function using Fluorine-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET). Methods Twenty First episode schizophrenia cases and 20 matched healthy controls living in the community were enrolled. For cases, longest duration of illness was one year and treatment with neuroleptic did not exceed two weeks on the day of scan. To measure facial emotion perception (FEP) both groups were administered the Emotion battery from the Penn Computerized Battery followed by PET acquisition. SPM 8 analysis for group differences at p<0.001 was performed. Results Schizophrenia subjects showed hypoactivation of bilateral prefrontal cortices and fusiform gyrii, with significant hyperactivation of bilateral basal ganglia and left precuneus. Positive correlation of metabolism in prefrontal cortex and performance indices on emotions domain was seen. No correlation of CPZ equivalent days with metabolism in basal ganglia was observed. Conclusions The performance of schizophrenia cases on FEP task was significantly impaired in comparison to the control group. Brain regions implicated in emotion processing showed hypometabolism in cases as compared to controls. Failure of schizophrenia cases to optimally recruit brain circuitry may be contributing to deficits on FEP task. These findings suggest inherent deficits in neural circuitry of emotion processing in schizophrenia; devoid of confounding effects of neuroleptics and duration of illness. PMID:25655909

  2. [Multi-center study of inter-scanner difference in brain positron emission tomography].

    PubMed

    Oda, Keiichi; Sakata, Muneyuki; Nishio, Tomoyuki; Tsushima, Hiroyuki; Tanizaki, Yasuo; Kato, Seiji; Ochi, Shinji

    2012-01-01

    We showed scanner dependence of brain (18)F-FDG and (11)C-PiB images by using phantom examination with nine kinds of positron emission tomography (PET) scanners. We used two types of phantoms, cylindrical phantom with 15 cm inside diameter and three-dimensional (3D) brain phantom, and we set the body phantom on the bed to examine the effect of scatter and random coefficients from outside of the axial field of view (AFOV). Radioactivity and distance of the two phantoms were determined by a pilot study to obtain a condition similar to the clinical study. Axial uniformity was evaluated by circular region of interest (ROI) of 12 cm diameter, set in the center of the reconstruction image of the cylindrical phantom. As a result, the standardized uptake value (SUV) was lower than the true value in some scanners, and there was a scanner in which the axial uniformity was deteriorated by high radioactivity outside the AFOV. In the cylindrical phantom, the axial uniformity of the scanner was improved using the new dead-time correction method; however, it was not improved in the 3D brain phantom. Quality-controlled PET scanners are important to maintain constant levels for multicenter studies.

  3. Clinical Utility of Positron Emission Tomography Magnetic Resonance Imaging (PET-MRI) in Gastrointestinal Cancers

    PubMed Central

    Matthews, Robert; Choi, Minsig

    2016-01-01

    Anatomic imaging utilizing both CT (computed tomography) and MRI (magnetic resonance imaging) limits the assessment of cancer metastases in lymph nodes and distant organs while functional imaging like PET (positron emission tomography) scan has its limitation in spatial resolution capacity. Hybrid imaging utilizing PET-CT and PET-MRI are novel imaging modalities that are changing the current landscape in cancer diagnosis, staging, and treatment response. MRI has shown to have higher sensitivity in soft tissue, head and neck pathology, and pelvic disease, as well as, detecting small metastases in the liver and bone compared to CT. Combining MRI with PET allows for detection of metastases that may have been missed with current imaging modalities. In this review, we will examine the clinical utility of FDG PET-MRI in the diagnosis and staging of gastrointestinal cancers with focus on esophageal, stomach, colorectal, and pancreatic cancers. We will also explore its role in treatment response and future directions associated with it. PMID:27618106

  4. Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

    PubMed

    Tsoumpas, Charalampos; Turkheimer, Federico E; Thielemans, Kris

    2008-04-01

    In dynamic positron emission tomography (PET) studies, the time changing activity of the radiotracer is measured through multiple consecutive frames. Subsequent pixel-by-pixel application of the appropriate kinetic model provides quantitative information in terms of images of the distribution of the physiological parameter of interest. In this context, iterative reconstruction methods may be used to reconstruct for each time frame a static image of appreciable higher quality than the analytical algorithms, especially in low-count cases. Furthermore, if the reconstruction algorithm also models the kinetics of the measured counts, the parametric image is expected to be of even higher quality. In this work, we investigate the methodology to directly reconstruct parametric images in three-dimensional PET when the kinetic model is linear in its parameters (Patlak plot) and compare with indirectly estimated parametric maps, where the radioactivity distribution was estimated by the filtered back projection and ordered subsets expectation maximization algorithms. Both real and simulated data for tracers with irreversible kinetics in brain studies are included. The results demonstrate appreciable smaller standard deviation and mean squared error characteristics for the direct reconstruction. However, some regions may converge slowly. The FBP and ordered subsets expectation maximization (OSEM) indirect estimations have a similar level of bias after matching their resolutions, but OSEM has smaller standard deviation.

  5. An investigation into positron emission tomography contouring methods across two treatment planning systems

    SciTech Connect

    Young, Tony; Som, Seu; Sathiakumar, Chithradevi; Holloway, Lois

    2013-04-01

    Positron emission tomography (PET) imaging has been used to provide additional information regarding patient tumor location, size, and staging for radiotherapy treatment planning purposes. This additional information reduces interobserver variability and produces more consistent contouring. It is well recognized that different contouring methodology for PET data results in different contoured volumes. The goal of this study was to compare the difference in PET contouring methods for 2 different treatment planning systems using a phantom dataset and a series of patient datasets. Contouring methodology was compared on the ADAC Pinnacle Treatment Planning System and the CMS XiO Treatment Planning System. Contours were completed on the phantom and patient datasets using a number of PET contouring methods—the standardized uptake value 2.5 method, 30%, 40%, and 50% of the maximum uptake method and the signal to background ratio method. Differences of >15% were observed for PET-contoured volumes between the different treatment planning systems for the same data and the same PET contouring methodology. Contoured volume differences between treatment planning systems were caused by differences in data formatting and display and the different contouring tools available. Differences in treatment planning system as well as contouring methodology should be considered carefully in dose-volume contouring and reporting, especially between centers that may use different treatment planning systems or those that have several different treatment planning systems.

  6. Positron emission tomography findings in children with infantile spasms and autism.

    PubMed

    Dilber, Cengiz; Calışkan, Mine; Sönmezoğlu, Kerim; Nişli, Serap; Mukaddes, Nahit Motavalli; Tatlı, Burak; Aydınlı, Nur; Ekici, Barış; Özmen, Meral

    2013-03-01

    The purpose of this study was to evaluate positron emission tomography (PET) findings in patients diagnosed with infantile spasms and autism. This study includes 90 patients who were diagnosed with infantile spasms at the Department of Pediatric Neurology in the Istanbul University Medical Faculty between 1995 and 2007. Of the 90 patients, 15 patients who were diagnosed with autism using the Autism Behaviour Checklist and Childhood Autism Rating Scale and a control group of nine patients without autism but with infantile spasms underwent PET examination. Mean patient age (± standard error, SE) varied between 3 years and 16 years (7.8 ± 4 years), while the mean follow-up time (±SE) varied between 2 years and 16 years (average: 7.1 ± 4 years). Autism was present in 11 patients with symptomatic spasms and in four patients with cryptogenic spasms (p=0.009). On the PET scans of the 15 patients with autism, 13 (86.7%) had significantly decreased metabolic activity in the temporal lobe (p<0.001), nine (60%) had significantly decreased activity in the frontal lobe (p=0.004), and seven (46.7%) had significantly decreased activity in the parietal lobe (p=0.022). In our opinion, hypometabolism in the frontal and parietal lobes, in addition to that previously reported in the temporal lobe, plays a role in the development of autism in patients with infantile spasms.

  7. Tumour response evaluation with fluorodeoxyglucose positron emission tomography: research technique or clinical tool?

    PubMed

    Anderson, H; Singh, N; Miles, K

    2010-10-04

    The evaluation of treatment response is an established role for imaging in oncologic research and clinical practice. In early phase trials, imaging response criteria are used to determine the presence and magnitude of the drug effect on tumour to aid decisions concerning progress to late phase trials, and to inform dose selection and scheduling. In late phase trials and clinical practice, the imaging response is used as a surrogate for clinical outcome. Due to the limitations of current anatomic response criteria, there is growing interest in the use of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET) to assess treatment response. The technique is beginning to be adopted within mainstream approaches for evaluation of response in solid tumours and lymphoma. Difficulties with standardisation across PET centres and tumour types combined with uncertainty concerning the timing of assessment relative to treatment, have limited the use of quantitative measurements of FDG uptake to research applications. However, with a growing body of evidence that qualitative criteria such as the development of new PET lesions or complete metabolic response following treatment can provide surrogates marker for clinical outcome, [(18)F]FDG-PET is becoming established as a clinical technique for assessing tumour response, especially for FDG-avid lymphoma subtypes. Multimodality imaging using perfusion computed tomography/PET is an exciting novel technique with the potential to define treatment response in a new way.

  8. Positron emission tomography in aging and dementia: effect of cerebral atrophy

    SciTech Connect

    Chawluk, J.B.; Alavi, A.; Dann, R.; Hurtig, H.I.; Bais, S.; Kushner, M.J.; Zimmerman, R.A.; Reivich, M.

    1987-04-01

    The spatial resolution of current positron emission tomography (PET) scanners does not allow a distinction between cerebrospinal fluid (CSF) containing spaces and contiguous brain tissue. Data analysis strategies which therefore purport to quantify cerebral metabolism per unit mass brain tissue are in fact measuring a value which may be artifactually reduced due to contamination by CSF. We studied cerebral glucose metabolism (CMRglc) in 17 healthy elderly individuals and 24 patients with Alzheimer's dementia using (/sup 18/F)fluorodeoxyglucose and PET. All subjects underwent x-ray computed tomography (XCT) scanning at the time of their PET study. The XCT scans were analyzed volumetrically, in order to determine relative areas for ventricles, sulci, and brain tissue. Global CMRglc was calculated before and after correction for contamination by CSF (cerebral atrophy). A greater increase in global CMRglc after atrophy correction was seen in demented individuals compared with elderly controls (16.9% versus 9.0%, p less than 0.0005). Additional preliminary data suggest that volumetric analysis of proton-NMR images may prove superior to analysis of XCT data in quantifying the degree of atrophy. Appropriate corrections for atrophy should be employed if current PET scanners are to accurately measure actual brain tissue metabolism in various pathologic states.

  9. Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography

    SciTech Connect

    Derenzo, S.E.

    1983-11-01

    Spatial resolution in positron emission tomography is currently limited by the resolution of the detectors. This work presents the initial characterization of a detector design using small bismuth germanate (BGO) crystals individually coupled to silicon photodiodes (SPDs) for crystal identification, and coupled in groups to phototubes (PMTs) for coincidence timing. A 3 mm x 3 mm x 3 mm BGO crystal coupled only to an SPD can achieve a 511 keV photopeak resolution of 8.7% FWHM at -150/sup 0/C, using a pulse peaking time of 10 ..mu..s. When two 3 mm x 3 mm x 15 mm BGO crystals are coupled individually to SPDs and also coupled to a common 14 mm diam PMT, the SPDs detect the 511 keV photopeak with a resolution of 30% FWHM at -76/sup 0/C. In coincidence with an opposing 3 mm wide BGO crystal, the SPDs are able to identify the crystal of interaction with good signal-to-noise ratio, and the detector pair resolution is 2 mm FWHM. 32 references, 7 figures, 3 tables.

  10. Effect of Harderian adenectomy on the statistical analyses of mouse brain imaging using positron emission tomography

    PubMed Central

    Kim, Minsoo; Woo, Sang-Keun; Yu, Jung Woo; Lee, Yong Jin; Kim, Kyeong Min; Kang, Joo Hyun; Eom, Kidong

    2014-01-01

    Positron emission tomography (PET) using 2-deoxy-2-[18F] fluoro-D-glucose (FDG) as a radioactive tracer is a useful technique for in vivo brain imaging. However, the anatomical and physiological features of the Harderian gland limit the use of FDG-PET imaging in the mouse brain. The gland shows strong FDG uptake, which in turn results in distorted PET images of the frontal brain region. The purpose of this study was to determine if a simple surgical procedure to remove the Harderian gland prior to PET imaging of mouse brains could reduce or eliminate FDG uptake. Measurement of FDG uptake in unilaterally adenectomized mice showed that the radioactive signal emitted from the intact Harderian gland distorts frontal brain region images. Spatial parametric measurement analysis demonstrated that the presence of the Harderian gland could prevent accurate assessment of brain PET imaging. Bilateral Harderian adenectomy efficiently eliminated unwanted radioactive signal spillover into the frontal brain region beginning on postoperative Day 10. Harderian adenectomy did not cause any post-operative complications during the experimental period. These findings demonstrate the benefits of performing a Harderian adenectomy prior to PET imaging of mouse brains. PMID:23820224

  11. Fluorodeoxyglucose-based positron emission tomography imaging to monitor drug responses in hematological tumors.

    PubMed

    Newbold, Andrea; Martin, Ben P; Cullinane, Carleen; Bots, Michael

    2014-10-01

    Positron emission tomography (PET) can be used to monitor the uptake of the labeled glucose analog fluorodeoxyglucose (¹⁸F-FDG), a process that is generally believed to reflect viable tumor cell mass. The use of ¹⁸F-FDG PET can be helpful in documenting over time the reduction in tumor mass volume in response to anticancer drug therapy in vivo. In this protocol, we describe how to monitor the response of murine B-cell lymphomas to an inducer of apoptosis, the anticancer drug vorinostat (a histone deacetylase inhibitor). B-cell lymphoma cells are injected into recipient mice and, on tumor formation, the mice are treated with vorinostat. The tracer ¹⁸F-FDG is then injected into the mice at several time points, and its uptake is monitored using PET. Because the uptake of ¹⁸F-FDG is not a direct measure of apoptosis, an additional direct method proving that apoptotic cells are present should also be performed.

  12. Fluorodeoxyglucose-based positron emission tomography imaging to monitor drug responses in solid tumors.

    PubMed

    Newbold, Andrea; Martin, Ben P; Cullinane, Carleen; Bots, Michael

    2014-10-01

    Positron emission tomography (PET) is used to monitor the uptake of the labeled glucose analogue fluorodeoxyglucose (¹⁸F-FDG) by solid tumor cells, a process generally believed to reflect viable tumor cell mass. The use of ¹⁸F-FDG exploits the high demand for glucose in tumor cells, and serves to document over time the response of a solid tumor to an inducer of apoptosis. The apoptosis inducer crizotinib is a small-molecule inhibitor of c-Met, a receptor tyrosine kinase that is often dysregulated in human tumors. In this protocol, we describe how to monitor the response of a solid tumor to crizotinib. Human gastric tumor cells (GTL-16 cells) are injected into recipient mice and, on tumor formation, the mice are treated with crizotinib. The tracer ¹⁸F-FDG is then injected into the mice at several time points, and its uptake is monitored using PET. Because ¹⁸F-FDG uptake varies widely among different tumor models, preliminary experiments should be performed with each new model to determine its basal level of ¹⁸F-FDG uptake. Verifying that the basal level of uptake is sufficiently above background levels will assure accurate quantitation. Because ¹⁸F-FDG uptake is not a direct measure of apoptosis, it is advisable to carry out an additional direct method to show the presence of apoptotic cells.

  13. The prognostic value of interim positron emission tomography scans combined with immunohistochemical data in diffuse large B-cell lymphoma.

    PubMed

    Fields, Paul A; Mikhaeel, George; Hutchings, Martin; van der Walt, Jon; Nunan, Tom; Schey, Steve A

    2005-12-01

    The treatment of hematologic malignancies is moving towards risk-stratified directed therapy, whereby treatment is based on the disease's biological characteristics and response to treatment. We investigated whether BCL2 and BCL6 status could add to the prognostic information yielded by an interim positron emission tomography (PET) scan in the ability to predict outcome. Negative interim scans and BCL2-negative status correlated with continuing remission (p<0.005) at a median follow up of 24 months.

  14. Intractable gelastic seizures during infancy: ictal positron emission tomography (PET) demonstrating epileptiform activity within the hypothalamic hamartoma.

    PubMed

    Shahar, Eli; Goldsher, Dorit; Genizi, Jacob; Ravid, Sarit; Keidar, Zohar

    2008-02-01

    Gelastic seizures comprise a very rare form of epilepsy. They present with recurrent bursts of laughter voices without mirth and are most commonly associated with the evolution of a hypothalamic hamartoma. The purpose of this article is to describe the second reported ictal fluorodeoxyglucose-positron emission tomography study in a unique case of an infant with intractable gelastic seizures since the neonatal period associated with a hypothalamic hamartoma. The patient presented at 4 months old with recurrent, almost persistent, gelastic seizures consisting of laughter bouts without mirth. The seizures were noticeable at the first week of life and increased in frequency to last up to 12 hours, namely status gelasticus. These gelastic fits were accompanied with focal motor seizures, including unilateral right-eye blinking and mouth twitching. Developmental mile-stones were intact for age. Magnetic resonance imaging of the cortex demonstrated a large hypothalamic hamartoma within the third ventricle, hampering cerebrovascular fluid drainage of the lateral ventricles. An electroencephalography was nondiagnostic. Ictal fluorodeoxyglucose-positron emission tomography demonstrated a large circumscribed hypermetabolic region within the location of the hypothalamic hamartoma, representing localized intense epileptiform activity. The infant became instantly free of all seizure types given minute doses of oral benzodiazepine (clonazepam) and remains completely controlled after 12 months. Her overall development remains intact. This ictal fluorodeoxyglucose-positron emission tomography is the second reported study verifying that the main source of the epileptic activity inducing gelastic seizures originates from the hypothalamic hamartoma itself; therefore, a complementary fluorodeoxyglucose-positron emission tomography study should be considered in any patient presenting with intractable gelastic seizures, especially in those associated with hypothalamic hamartoma, in order

  15. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    PubMed Central

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18F-fluorodeoxyglucose positron emission tomography/computed tomography. PMID:26097425

  16. Pneumococcal aortitis, report of a case with emphasis on the contribution to diagnosis of positron emission tomography using fluorinated deoxyglucose.

    PubMed

    Hoogendoorn, E H; Oyen, W J G; van Dijk, A P J; van der Meer, J W M

    2003-01-01

    We describe an 82-year-old male with pneumococcal aortitis of the descending aorta, visualized by echocardiography and positron emission tomography using fluorinated deoxyglucose (FDG-PET). Computed tomography is considered to be the best diagnostic imaging modality in infected aortic lesions; in this case, the use of FDG-PET, which gives the opportunity to distinguish between inflammatory and non-inflammatory aortic aneurysms, made an important contribution to the diagnosis.

  17. Diagnosis of Alzheimer-type dementia: a preliminary comparison of positron emission tomography and proton magnetic resonance

    SciTech Connect

    Friedland, R.P.; Budinger, T.F.; Brant-Zawadzki, M.; Jagust, W.J.

    1984-11-16

    The use of positron emission tomography with (18F)-2-fluoro-2-deoxy-D-glucose (FDG) to study glucose metabolism in dementia is described and compared with the use of magnetic resonance imaging. These studies suggest that physiological imaging with PET may be superior to MR as it is currently used in the diagnosis of dementia-like diseases. Pet is currently limited to a few centers; however, single photon emission CT can provide regional physiological data without the need for a local cyclotron. 15 references, 2 tables.

  18. Volunteerism and Self-Selection Bias in Human Positron Emission Tomography Neuroimaging Research

    PubMed Central

    Oswald, Lynn M.; Wand, Gary S.; Zhu, Shijun; Selby, Victoria

    2012-01-01

    Scientists have known for decades that persons who volunteer for behavioral research may be different from those who decline participation and that characteristics differentiating volunteers from non-volunteers may vary depending on the nature of the research. There is evidence that volunteer self-selection can impact representativeness of samples in studies involving physically or psychologically stressful procedures, such as electric shocks, sensory isolation, or drug effects. However, the degree to which self-selection influences sample characteristics in “stressful” studies involving positron emission tomography (PET) has not been evaluated. Since estimation of population parameters, robustness of findings, and validity of inferred relationships can all be impacted by volunteer bias, it is important to determine if self-selection may act as an unrecognized confound in such studies. In the present investigation, we obtained baseline data on 114 M, F subjects who participated in a study involving completion of several self-report questionnaires and behavioral performance tasks. Participants were later given the opportunity to enroll in an [11C]raclopride PET study involving intravenous amphetamine (AMPH) administration. Demographic characteristics, personality traits, and task performance of subjects who consented to the latter study were compared with those who declined participation. Findings showed that the principal personality trait that distinguished the two groups was sensation-seeking; volunteers scored significantly higher on this dimension than non-volunteers. Males were more likely to volunteer than females. However, results of mediation analysis suggested that the relationship between gender and volunteer status was mediated by greater sensation-seeking traits in the males. Implications of these findings are discussed. PMID:23196924

  19. 18F-fluorodeoxyglucose positron-emission tomography-computed tomography to diagnose recurrent cancer

    PubMed Central

    You, J J; Cline, K J; Gu, C-S; Pritchard, K I; Dayes, I S; Gulenchyn, K Y; Inculet, R I; Dhesy-Thind, S K; Freeman, M A; Chan, A M; Julian, J A; Levine, M N

    2015-01-01

    Background: Sometimes the diagnosis of recurrent cancer in patients with a previous malignancy can be challenging. This prospective cohort study assessed the clinical utility of 18F-fluorodeoxyglucose positron-emission tomography-computed tomography (18F-FDG PET-CT) in the diagnosis of clinically suspected recurrence of cancer. Methods: Patients were eligible if cancer recurrence (non-small-cell lung (NSCL), breast, head and neck, ovarian, oesophageal, Hodgkin's or non-Hodgkin's lymphoma) was suspected clinically, and if conventional imaging was non-diagnostic. Clinicians were asked to indicate their management plan before and after 18F-FDG PET-CT scanning. The primary outcome was change in planned management after 18F-FDG PET-CT. Results: Between April 2009 and June 2011, 101 patients (age, median 65 years; 55% female) were enroled from four cancer centres in Ontario, Canada. Distribution by primary tumour type was: NSCL (55%), breast (19%), ovarian (10%), oesophageal (6%), lymphoma (6%), and head and neck (4%). Of the 99 subjects who underwent 18F-FDG PET-CT, planned management changed after 18F-FDG PET-CT in 52 subjects (53%, 95% confidence interval (CI), 42–63%); a major change in plan from no treatment to treatment was observed in 38 subjects (38%, 95% CI, 29–49%), and was typically associated with 18F-FDG PET-CT findings that were positive for recurrent cancer (37 subjects). After 3 months, the stated post-18F-FDG PET-CT management plan was actually completed in 88 subjects (89%, 95% CI, 81–94%). Conclusion: In patients with suspected cancer recurrence and conventional imaging that is non-diagnostic, 18F-FDG PET-CT often provides new information that leads to important changes in patient management. PMID:25942398

  20. Positron Emission Tomography Image-Guided Drug Delivery: Current Status and Future Perspectives

    PubMed Central

    2015-01-01

    Positron emission tomography (PET) is an important modality in the field of molecular imaging, which is gradually impacting patient care by providing safe, fast, and reliable techniques that help to alter the course of patient care by revealing invasive, de facto procedures to be unnecessary or rendering them obsolete. Also, PET provides a key connection between the molecular mechanisms involved in the pathophysiology of disease and the according targeted therapies. Recently, PET imaging is also gaining ground in the field of drug delivery. Current drug delivery research is focused on developing novel drug delivery systems with emphasis on precise targeting, accurate dose delivery, and minimal toxicity in order to achieve maximum therapeutic efficacy. At the intersection between PET imaging and controlled drug delivery, interest has grown in combining both these paradigms into clinically effective formulations. PET image-guided drug delivery has great potential to revolutionize patient care by in vivo assessment of drug biodistribution and accumulation at the target site and real-time monitoring of the therapeutic outcome. The expected end point of this approach is to provide fundamental support for the optimization of innovative diagnostic and therapeutic strategies that could contribute to emerging concepts in the field of “personalized medicine”. This review focuses on the recent developments in PET image-guided drug delivery and discusses intriguing opportunities for future development. The preclinical data reported to date are quite promising, and it is evident that such strategies in cancer management hold promise for clinically translatable advances that can positively impact the overall diagnostic and therapeutic processes and result in enhanced quality of life for cancer patients. PMID:24865108

  1. Accuracy of 18F fluorodeoxyglucose positron emission tomography/computed tomography in staging of pediatric sarcomas.

    PubMed

    Tateishi, Ukihide; Hosono, Ako; Makimoto, Atsushi; Sakurada, Aine; Terauchi, Takashi; Arai, Yasuaki; Imai, Yutaka; Kim, Euishin Edmund

    2007-09-01

    The present study was conducted to clarify the diagnostic accuracy of 18F-fluoro-2-deoxy-D-glucose (18FDG) positron emission tomography (PET)/computed tomography (CT) in the staging in pediatric sarcomas. Fifty pediatric patients with histologically proven sarcomas who underwent 18FDG PET/CT before treatment were evaluated retrospectively for the detection of nodal and distant metastases. Diagnostic accuracy of 18FDG PET/CT in detecting nodal and distant metastases was compared with that of 18FDG PET and conventional imaging (CI). The images were reviewed and a diagnostic consensus was reached by 3 observers. REFERENCE standard was histologic examination in 15 patients and confirmation of an obvious progression in size of the lesions on follow-up examinations. Nodal metastasis was correctly assessed in 48 patients (96%) with PET/CT, in contrast to 43 patients (86%) with PET, and 46 patients (92%) with CI. Diagnostic accuracies of nodal metastasis in 3 modalities were similar. Using PET/CT, distant metastasis was correctly assigned in 43 patients (86%), whereas interpretation based on PET alone or CI revealed distant metastasis in 33 patients (66%) and 35 patients (70%), respectively. Diagnostic accuracy of distant metastasis with PET/CT was significantly higher than that of PET (P=0.002) or CI (P=0.008). False negative results regarding distant metastasis by PET/CT in 7 patients (14%) were caused by subcentimetric lesions (n=4), bone marrow lesion (n=2), and soft tissue lesions (n=1). PET/CT is more accurate and probably more cost-effective than PET alone or CI regarding distant metastasis in pediatric sarcomas.

  2. Development of an angled Si-PM-based detector unit for positron emission mammography (PEM) system

    NASA Astrophysics Data System (ADS)

    Nakanishi, Kouhei; Yamamoto, Seiichi

    2016-11-01

    Positron emission mammography (PEM) systems have higher sensitivity than clinical whole body PET systems because they have a smaller ring diameter. However, the spatial resolution of PEM systems is not high enough to detect early stage breast cancer. To solve this problem, we developed a silicon photomultiplier (Si-PM) based detector unit for the development of a PEM system. Since a Si-PM's channel is small, Si-PM can resolve small scintillator pixels to improve the spatial resolution. Also Si-PM based detectors have inherently high timing resolution and are able to reduce the random coincidence events by reducing the time window. We used 1.5×1.9×15 mm LGSO scintillation pixels and arranged them in an 8×24 matrix to form scintillator blocks. Four scintillator blocks were optically coupled to Si-PM arrays with an angled light guide to form a detector unit. Since the light guide has angles of 5.625°, we can arrange 64 scintillator blocks in a nearly circular shape (a regular 64-sided polygon) using 16 detector units. We clearly resolved the pixels of the scintillator blocks in a 2-dimensional position histogram where the averages of the peak-to-valley ratios (P/Vs) were 3.7±0.3 and 5.7±0.8 in the transverse and axial directions, respectively. The average energy resolution was 14.2±2.1% full-width at half-maximum (FWHM). By including the temperature dependent gain control electronics, the photo-peak channel shifts were controlled within ±1.5% with the temperature from 23 °C to 28 °C. With these results, in addition to the potential high timing performance of Si-PM based detectors, our developed detector unit is promising for the development of a high-resolution PEM system.

  3. Noninvasive evaluation of sympathetic nervous system in human heart by positron emission tomography

    SciTech Connect

    Schwaiger, M.; Kalff, V.; Rosenspire, K.; Haka, M.S.; Molina, E.; Hutchins, G.D.; Deeb, M.; Wolfe, E. Jr.; Wieland, D.M. )

    1990-08-01

    The noninvasive functional characterization of the cardiac sympathetic nervous system by imaging techniques may provide important pathophysiological information in various cardiac disease states. Hydroxyephedrine labeled with carbon 11 has been developed as a new catecholamine analogue to be used in the in vivo evaluation of presynaptic adrenergic nerve terminals by positron emission tomography (PET). To determine the feasibility of this imaging approach in the human heart, six normal volunteers and five patients with recent cardiac transplants underwent dynamic PET imaging after intravenous injection of 20 mCi (11C)hydroxyephedrine. Blood and myocardial tracer kinetics were assessed using a regions-of-interest approach. In normal volunteers, blood 11C activity cleared rapidly, whereas myocardium retained 11C activity with a long tissue half-life. Relative tracer retention in the myocardium averaged 79 +/- 31% of peak activity at 60 minutes after tracer injection. The heart-to-blood 11C activity ratio exceeded 6:1 as soon as 30 minutes after tracer injection, yielding excellent image quality. Little regional variation of tracer retention was observed, indicating homogeneous sympathetic innervation throughout the left ventricle. In the transplant recipients, myocardial (11C)hydroxyephedrine retention at 60 minutes was significantly less (-82%) than that of normal volunteers, indicating only little non-neuronal binding of the tracer in the denervated human heart. Thus, (11C)hydroxyephedrine, in combination with dynamic PET imaging, allows the noninvasive delineation of myocardial adrenergic nerve terminals. Tracer kinetic modeling may permit quantitative assessment of myocardial catecholamine uptake, which will in turn provide insights into the effects of various disease processes on the neuronal integrity of the heart.

  4. Glycine Transporter Type 1 Occupancy by Bitopertin: a Positron Emission Tomography Study in Healthy Volunteers

    PubMed Central

    Martin-Facklam, Meret; Pizzagalli, Flavia; Zhou, Yun; Ostrowitzki, Susanne; Raymont, Vanessa; Brašić, James R; Parkar, Nikhat; Umbricht, Daniel; Dannals, Robert F; Goldwater, Ron; Wong, Dean F

    2013-01-01

    Deficient N-methyl-D-aspartate (NMDA) receptor transmission is thought to underlie schizophrenia. An approach for normalizing glutamate neurotransmission by enhancing NMDA receptor transmission is to increase glycine availability by inhibiting the glycine transporter type 1 (GlyT1). This study investigated the relationship between the plasma concentration of the glycine reuptake inhibitor bitopertin (RG1678) and brain GlyT1 occupancy. Healthy male volunteers received up to 175 mg bitopertin once daily, for 10–12 days. Three positron emission tomography scans, preceded by a single intravenous infusion of ∼30 mCi [11C]RO5013853, were performed: at baseline, on the last day of bitopertin treatment, and 2 days after drug discontinuation. Eighteen subjects were enrolled. At baseline, regional volume of distribution (VT) values were highest in the pons, thalamus, and cerebellum (1.7–2.7 ml/cm3) and lowest in cortical areas (∼0.8 ml/cm3). VT values were reduced to a homogeneous level following administration of 175 mg bitopertin. Occupancy values derived by a two-tissue five-parameter (2T5P) model, a simplified reference tissue model (SRTM), and a pseudoreference tissue model (PRTM) were overall comparable. At steady state, the relationship between bitopertin plasma concentration and GlyT1 occupancy derived by the 2T5P model, SRTM, and PRTM exhibited an EC50 of ∼190, ∼200, and ∼130 ng/ml, respectively. Emax was ∼92% independently of the model used. Bitopertin plasma concentration was a reliable predictor of occupancy because the concentration–occupancy relationship was superimposable at steady state and 2 days after drug discontinuation. These data allow understanding of the concentration–occupancy–efficacy relationship of bitopertin and support dose selection of future molecules. PMID:23132267

  5. [Positron emission tomography in the Netherlands: need to expand the capacity].

    PubMed

    Comans, E F I; Smit, E F

    2002-09-28

    Positron emission tomography with 18fluor-2-deoxy-D-glucose (FDG-PET) is increasingly used in clinical practice, especially in oncology. However, in the Netherlands, guidelines for its routine use are lacking, probably due to the limited availability and costs of PET technology. The increasing demand for evidence of a positive effect on patient management (and outcome) following the introduction of new diagnostic tests, also plays an important role. For non-small cell lung cancer (NSCLC) such evidence is now available. In a prospective randomised multicentre study performed in the Comprehensive Cancer Centre in Amsterdam, FDG-PET reduced the number of futile thoracotomies in patients with suspected NSCLC by 50%. This and other studies resulted in a regional guideline (formulated by pulmonologists, surgeons, radiotherapists, radiologists and nuclear medicine physicians) for the use of FDG-PET in patients with (suspected) NSCLC. Several, predominantly multicentre, studies to evaluate the effectiveness of FDG-PET in subgroups of patients with colorectal cancer, breast cancer, oesophageal cancer, ENT tumours, non-Hodgkin's lymphoma and NSCLC (early in the diagnostic workup), are currently being undertaken in the Netherlands. The results of these might facilitate a cost-effective positioning of PET technology for routine patient care in the Netherlands. A recent report from the Comprehensive Cancer Centre in the south of the Netherlands, based on scenarios in Belgium and the United States, indicates that the availability of PET facilities should increase substantially over the next decade, so as to ensure access to all patients who may benefit from this technology.

  6. EndoTOFPET-US - A Miniaturised Calorimeter for Endoscopic Time-of-Flight Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zvolský, Milan; EndoTOFPET-US Collaboration

    2015-02-01

    In the scope of the EndoTOFPET-US project, a novel multimodal device for Ultrasound (US) Endoscopy and Positron Emission Tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional markers and developing new biomarkers for pancreas and prostate oncology. Exploiting the Time-of-Flight (TOF) information of the gamma rays allows for a more sensitive, more precise and lower radiation- dose imaging and intervention on small internal structures. The detection of the gamma rays is realised with the help of scintillator crystals with Silicon Photomultiplier (SiPM) read-out, aiming at a coincidence time resolution of 200 ps and a spatial resolution of ≈ 1 mm. For the endoscopic detector, digital SiPMs are utilised for the first time in an instrument planned for clinical applications. The functionality of the instrument as well as the challenges that accompany the high miniaturisation of the endoscopic detector and the asymmetric and variable geometry of the system, are presented. The demands on the system involve the fields of scintillating crystallography, ultra-fast photon detection, highly integrated electronics, system integration as well as image reconstruction. The single detector components have been fully characterised and are performing up to specifications. Two dedicated ASIC chips have been developed for the project. The first PET images have been acquired with a test setup that consists solely of hardware and software developed within the collaboration and demonstrate that the data acquisition and reconstruction chain is operational. In this talk, the characterisation of the single components and the status of the detector integration and comissioning is presented.

  7. Metabolic positron emission tomography imaging of cancer: Pairing lipid metabolism with glycolysis

    PubMed Central

    Kwee, Sandi A; Lim, John

    2016-01-01

    The limitations of fluorine-18 fluorodeoxy-D-glucose (FDG) in detecting some cancers has prompted a longstanding search for other positron emission tomography (PET) tracers to complement the imaging of glycolysis in oncology, with much attention paid to lipogenesis based on observations that the production of various lipid and lipid-containing compounds is increased in most cancers. Radiolabeled analogs of choline and acetate have now been used as oncologic PET probes for over a decade, showing convincingly improved detection sensitivity over FDG for certain cancers. However, neither choline nor acetate have been thoroughly validated as lipogenic biomarkers, and while acetyl-CoA produced from acetate is used in de-novo lipogenesis to synthesize fatty acids, acetate is also consumed by various other synthetic and metabolic pathways, with recent experimental observations challenging the assumption that lipogenesis is its predominant role in all cancers. Since tumors detected by acetate PET are also frequently detected by choline PET, imaging of choline metabolism might serve as an alternative albeit indirect marker of lipogenesis, particularly if the fatty acids produced in cancer cells are mainly destined for membrane synthesis through incorporation into phosphatidylcholines. Aerobic glycolysis may or may not coincide with changes in lipid metabolism, resulting in combinatorial metabolic phenotypes that may have different prognostic or therapeutic implications. Consequently, PET imaging using dual metabolic tracers, in addition to being diagnostically superior to imaging with individual tracers, could eventually play a greater role in supporting precision medicine, as efforts to develop small-molecule metabolic pathway inhibitors are coming to fruition. To prepare for this advent, clinical and translational studies of metabolic PET tracers must go beyond simply estimating tracer diagnostic utility, and aim to uncover potential therapeutic avenues associated with

  8. Imaging substance P receptors (NK1) in the living human brain using positron emission tomography.

    PubMed

    Hargreaves, Richard

    2002-01-01

    Substance P (SP)-neurokinin-1 (NK1) receptor pathways have been implicated in the pathophysiology of emesis and depression. Autoradiographic studies in monkey and human brains have shown a high expression of NK1 receptors in regions important for the regulation of affective behaviors and the neurochemical response to stress. Furthermore, clinical studies demonstrated that treatment with the SP (NK1 receptor) antagonist (SPA) aprepitant (also known as MK-0869) significantly improves depression symptoms and reduces the incidence of chemotherapy-induced nausea and vomiting. An important objective of all neuroscience drug discovery and development programs is to establish the correlation between dose, receptor occupancy, and the observed clinical effect (the dose-response relationship). These goals can be achieved using radioactive receptor-specific tracers and dynamic noninvasive brain imaging modalities, such as positron emission tomography (PET). In the SPA program, a tracer [18F]SPA-RQ was chosen for PET studies on the basis of several criteria, including high affinity for the NK1 receptor, low nonspecific binding, and good blood-brain barrier penetration. PET imaging studies in rhesus monkeys and humans confirmed these tracer features and established the usefulness of this probe for in vivo NK1 receptor occupancy studies. Subsequent PET occupancy studies in humans predicted that very high levels of central NK1 receptor occupancy (> 90%) were associated with therapeutically significant antidepressant and antiemetic effects. Future PET imaging studies will focus on quantification of NK1 receptor expression in depressed patients, both before and after successful treatment with antidepressants.

  9. PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography.

    PubMed

    Thomas, Benjamin A; Cuplov, Vesna; Bousse, Alexandre; Mendes, Adriana; Thielemans, Kris; Hutton, Brian F; Erlandsson, Kjell

    2016-11-21

    Positron emission tomography (PET) images are degraded by a phenomenon known as the partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically through the utilisation of structural information provided by other imaging modalities such as MRI or CT. These methods, known as partial volume correction (PVC) techniques, reduce PVEs by compensating for the effects of the scanner resolution, thereby improving the quantitative accuracy. The PETPVC toolbox described in this paper comprises a suite of methods, both classic and more recent approaches, for the purposes of applying PVC to PET data. Eight core PVC techniques are available. These core methods can be combined to create a total of 22 different PVC techniques. Simulated brain PET data are used to demonstrate the utility of toolbox in idealised conditions, the effects of applying PVC with mismatched point-spread function (PSF) estimates and the potential of novel hybrid PVC methods to improve the quantification of lesions. All anatomy-based PVC techniques achieve complete recovery of the PET signal in cortical grey matter (GM) when performed in idealised conditions. Applying deconvolution-based approaches results in incomplete recovery due to premature termination of the iterative process. PVC techniques are sensitive to PSF mismatch, causing a bias of up to 16.7% in GM recovery when over-estimating the PSF by 3 mm. The recovery of both GM and a simulated lesion was improved by combining two PVC techniques together. The PETPVC toolbox has been written in C++, supports Windows, Mac and Linux operating systems, is open-source and publicly available.

  10. Positron emission tomography imaging of braintumors with Cobalt-55 and L-[1-C11]-tyrosine

    SciTech Connect

    Jansen, H.M.L.; Pruim J.; Willemsen, A.T.M.

    1994-05-01

    The applicability of positron emission tomography (PET) with [C-11] tyrosine (TYR) and Cobalt-55 (Co) in patients with known primary brain tumors is reported. We used Co as a Calcium (Ca) marker to study Ca influx in degenerating neural tissue and TYR to indicate incorporation of amino acids into protein. Four patients showing a primary brain tumor with central necrosis on CT/MRI were studied with Co-PET. Additionally, 2 of these patients were consecutively studied with TYR-PET. Diagnostic confirmation was obtained by means of histology and/or cytology shortly after PET. Thirty-seven MBq Co was administered iv. approximately 24 hours before acquisition. The Co-scan was acquired for I hour. Immediately following Co-PET, 2 patients received 370 MBq TYR iv. TYR-PET acquisition was done dynamically for 55 minutes starting from the time of injection. The necrotic center of the tumor revealed no uptake of either Co or TYR. Vital tumor tissue showed intense uptake of TYR, indicating a high protein synthesis rate (PSR). The circumferent zone between necrotic and tumor tissue showed evident uptake of Co, suggesting cell-decay. In conclusion, TYR and Co are both suitable tracers for visualization of different aspects of brain malignancies, ie. PSR and cell-decay. Combining Co and TYR enables differentiation of necrosis vs. tumor growth with clear marking of the border zone. We think these complementary PET-techniques in conjunction with CT and/or MRI allow the visualization of different aspects of tumor tissue: central necrosis (CT/MRI), cell-decay (Co-PET) and vital tumor tissue (TYR-PET).

  11. Whole-body energy mapping under physical exercise using positron emission tomography.

    PubMed

    Iemitsu, M; Itoh, M; Fujimoto, T; Tashiro, M; Nagatomi, R; Ohmori, H; Ishii, K

    2000-12-01

    We attempted to visualize dynamic adjustment of glucose utilization in humans in the whole-body organs during physical exercise by using three-dimensional positron emission tomography (3D-PET) and [18F]-2-fluoro-deoxy-glucose (FDG). Twelve healthy male volunteers collaborated on the study; six subjects were assigned to the resting control group (C) and the other six to the running group (E). Group E subjects performed running on a flat road for 35 min. After 15 min of running, subjects injected FDG and kept on running thereafter for another 20 min. Group C subjects sat on a comfortable chair in a quiet room for 35 min after the injection of FDG. After scanning by PET, the regions of interest (ROIs) were manually set on brain, heart, thorax, abdomen, lower extremities, and the rest of the body on the corresponding transaxial images. The uptake of FDG in each region was evaluated as the % fraction of FDG accumulation relative to the total amount of whole-body accumulation. The results revealed increase of FDG uptake after running in the lower leg muscles from 24.6 +/- 9.5% to 43.1 +/- 4.7% and in the heart from 2.3 +/- 0.4% to 2.8 +/- 0.6%. The differences were significant (P < 0.05). These increases reflect the rise in energy consumption in leg and heart muscles and were balanced by the reduction of energy consumption in the other part of the body. FDG uptake in the abdominal region reduced from 37.3 +/- 7.2% to 19.7 +/- 4.9%. However, FDG uptake in the brain remained stable, i.e., 11.9 +/- 2.8% at rest and 10.3 +/- 2.5% after exercise. Thus, 3D-PET is a tool to visualize the dynamic adjustment of energy consumption during physical exercise in humans.

  12. Differentiating cardiomyopathy of coronary artery disease from nonischemic dilated cardiomyopathy utilizing positron emission tomography

    SciTech Connect

    Mody, F.V.; Brunken, R.C.; Stevenson, L.W.; Nienaber, C.A.; Phelps, M.E.; Schelbert, H.R. )

    1991-02-01

    To determine if imaging of blood flow (using N-13 ammonia) and glucose metabolism (using F-18 2-deoxyglucose) with positron emission tomography can distinguish cardiomyopathy of coronary artery disease from nonischemic dilated cardiomyopathy, 21 patients with severe left ventricular dysfunction who were evaluated for cardiac transplantation were studied. The origin of left ventricular dysfunction had been previously determined by coronary angiography to be ischemic (11 patients) or nonischemic (10 patients). Images were visually analyzed by three observers on a graded scale in seven left ventricular segments and revealed fewer defects in dilated cardiomyopathy compared with ischemic cardiomyopathy for N-13 ammonia (2.7 +/- 1.6 versus 5 +/- 0.6; p less than 0.03) and F-18 deoxyglucose (2.8 +/- 2.1 versus 4.6 +/- 1.1; p less than 0.03). An index incorporating extent and severity of defects revealed more homogeneity with fewer and less severe defects in subjects with nonischemic than in those with ischemic cardiomyopathy as assessed by imaging of flow (2.8 +/- 1.8 versus 9.2 +/- 3; p less than 0.001) and metabolism (3.8 +/- 3.3 versus 8.5 +/- 3.6; p less than 0.005). Diagnostic accuracy for distinguishing the two subgroups by visual image analysis was 85%. Using previously published circumferential count profile criteria, patients with dilated cardiomyopathy had fewer ischemic segments (0.4 +/- 0.8 versus 2.5 +/- 2 per patient; p less than 0.01) and infarcted segments (0.1 +/- 0.3 versus 2.4 +/- 1.4 per patient; p less than 0.001) than did patients with cardiomyopathy of coronary artery disease. The sensitivity for differentiating the two clinical subgroups using circumferential profile analysis was 100% and the specificity 80%.

  13. The Usefulness of Positron-Emission Tomography Findings in the Management of Anterior Mediastinal Tumors

    PubMed Central

    Sano, Fumitoshi; Ohashi, Shinichi; Suzuki, Kosuke; Uematsu, Shugo; Suzuki, Takashi; Kadokura, Mitsutaka

    2017-01-01

    Purpose: We performed a retrospective analysis to evaluate the usefulness of positron-emission tomography/computed tomography (PET/CT) findings in the classification and management of anterior mediastinal tumors. Methods: Between 2006 and 2015, 105 patients with anterior mediastinal tumor received PET/CT. 18F-fluorodeoxyglucose (18F-FDG)-PET images were obtained 60 minutes after the injection of 18F-FDG. Results: The histological classifications were as follows: thymoma (n = 49), thymic carcinoma (TC) (n = 19), malignant lymphoma (ML) (n = 8), teratoma (n = 7), thymic cyst (n = 14), and others (n = 8). Upon visual inspection (SUV max: >2.0), all of the malignant tumors showed 18F-FDG accumulation (with the exception of one type A thymoma). Two of the 14 thymic cysts and three of the seven teratomas showed slight 18F-FDG accumulation. The SUV max values of the low-grade thymomas, high-grade thymomas, TCs and MLs were 3.14 ± 0.73, 4.34 ± 1.49, 8.59 ± 3.05, and 10.08 ± 2.53, respectively, with significant differences between the low- and high-grade thymomas, and between TCs and MLs. The sensitivity, specificity and accuracy of 18F-FDG in the detection of low-grade thymomas and thymomas with a maximum diameter of ≤50 mm and an SUV max of ≤3.4 were 85%, 48%, and 60%, respectively. Conclusion: FDG-PET/CT is an objective and useful modality in the differential diagnosis and management of anterior mediastinal tumors. PMID:28123154

  14. Trends in radiation protection of positron emission tomography/computed tomography imaging.

    PubMed

    Alenezi, A; Soliman, K

    2015-06-01

    Over the past decade, the number of positron emission tomography/computed tomography (PET/CT) imaging procedures has increased substantially. This imaging technique provides accurate functional and anatomical information, particularly for oncological applications. Separately, both PET and CT are considered as high-dose imaging modalities. With the increased use of PET/CT, one could expect an increase in radiation doses to staff and patients. As such, major efforts have been made to reduce radiation dose in PET/CT facilities. Variations in working techniques have made it difficult to compare published results. This study aimed to review the literature on proposed methods to reduce patient and staff dose in clinical PET/CT imaging. A brief overview of some published information on staff and patient doses will be analysed and presented. Recent trends regarding radiation protection in PET/CT imaging will be discussed, and practical recommendations for reducing radiation doses to staff and patients will be discussed and summarised. Generally, the CT dose component is often higher in magnitude than the dose from PET alone; as such, focusing on CT dose reduction will decrease the overall patient dose in PET/CT imaging studies. The following factors should be considered in order to reduce the patient's dose from CT alone: proper justification for ordering contrast-enhanced CT; use of automatic exposure control features; use of adaptive statistical iterative reconstruction algorithms; and optimisation of scan parameters, especially scan length. The PET dose component can be reduced by administration of lower activity to the patient, optimisation of the workflow, and appropriate use of protective devices and engineered systems. At the international level, there is wide variation in work practices among institutions. The current observed trends are such that the annual dose limits for radiation workers in PET/CT imaging are unlikely to be exceeded.

  15. Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

    PubMed

    Karakatsanis, Nicolas A; Fokou, Eleni; Tsoumpas, Charalampos

    2015-01-01

    Positron emission tomography (PET) is widely used nowadays for tumor staging and therapy response in the clinic. However, average PET radiation exposure has increased due to higher PET utilization. This study aims to review state-of-the-art PET tracer dosage optimization methods after accounting for the effects of human body attenuation and scan protocol parameters on the counting rate. In particular, the relationship between the noise equivalent count rate (NECR) and the dosage (NECR-dosage curve) for a range of clinical PET systems and body attenuation sizes will be systematically studied to prospectively estimate the minimum dosage required for sufficiently high NECR. The optimization criterion can be determined either as a function of the peak of the NECR-dosage curve or as a fixed NECR score when NECR uniformity across a patient population is important. In addition, the systematic NECR assessments within a controllable environment of realistic simulations and phantom experiments can lead to a NECR-dosage response model, capable of predicting the optimal dosage for every individual PET scan. Unlike conventional guidelines suggesting considerably large dosage levels for obese patients, NECR-based optimization recommends: i) moderate dosage to achieve 90% of peak NECR for obese patients, ii) considerable dosage reduction for slimmer patients such that uniform NECR is attained across the patient population, and iii) prolongation of scans for PET/MR protocols, where longer PET acquisitions are affordable due to lengthy MR sequences, with motion compensation becoming important then. Finally, the need for continuous adaptation of dosage optimization to emerging technologies will be discussed.

  16. Evaluation of response to immune checkpoint inhibitors: Is there a role for positron emission tomography?

    PubMed Central

    Bauckneht, Matteo; Piva, Roberta; Sambuceti, Gianmario; Grossi, Francesco; Morbelli, Silvia

    2017-01-01

    Strategies targeting intracellular negative regulators such as immune checkpoint inhibitors (ICPIs) have demonstrated significant antitumor activity across a wide range of solid tumors. In the clinical practice, the radiological effect of immunotherapeutic agents has raised several more relevant and complex challenges for the determination of their imaging-based response at single patient level. Accordingly, it has been suggested that the conventional Response Evaluation Criteria in Solid Tumors assessment alone, based on dimensional evaluation provided by computed tomography (CT), tends to underestimate the benefit of ICPIs at least in a subset of patients, supporting the need of immune-related response criteria. Different from CT, very few data are available for the evaluation of immunotherapy by means of 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET). Moreover, since the antineoplastic activity of ICPIs is highly related to the activation of T cells against cancer cells, FDG accumulation might cause false-positive findings. Yet, discrimination between benign and malignant processes represents a huge challenge for FDG-PET in this clinical setting. Consequently, it might be of high interest to test the complex and variegated response to ICPIs by means of PET and thus it is worthwhile to ask if a similar introduction of immune-related PET-based criteria could be proposed in the future. Finally, PET might offer a new insight into the biology and pathophysiology of ICPIs thanks to a growing number of non-invasive immune-diagnostic approaches based on non-FDG tracers. PMID:28298962

  17. Four-Dimensional Positron Emission Tomography: Implications for Dose Painting of High-Uptake Regions

    SciTech Connect

    Aristophanous, Michalis; Killoran, Joseph H.; Chen, Aileen B.; Berbeco, Ross I.

    2011-07-01

    Purpose: To investigate the behavior of tumor subvolumes of high [18F]-fluorodeoxyglucose (FDG) uptake as seen on clinical four-dimensional (4D) FDG-positron emission tomography (PET) scans. Methods and Materials: Four-dimensional FDG-PET/computed tomography scans from 13 patients taken before radiotherapy were available. The analysis was focused on regions of high uptake that are potential dose-painting targets. A total of 17 lesions (primary tumors and lymph nodes) were analyzed. On each one of the five phases of the 4D scan a classification algorithm was applied to obtain the region of highest uptake and segment the tumor volume. We looked at the behavior of both the high-uptake subvolume, called 'Boost,' and the segmented tumor volume, called 'Target.' We measured several quantities that characterize the Target and Boost volumes and quantified correlations between them. Results: The behavior of the Target could not always predict the behavior of the Boost. The shape deformation of the Boost regions was on average 133% higher than that of the Target. The gross to internal target volume expansion was on average 27.4% for the Target and 64% for the Boost, a statistically significant difference (p < 0.05). Finally, the inhale-to-exhale phase (20%) had the highest shape deformation for the Boost regions. Conclusions: A complex relationship between the measured quantities for the Boost and Target volumes is revealed. The results suggest that in cases in which advanced therapy techniques such as dose painting are being used, a close examination of the 4D PET scan should be performed.

  18. Development of a multiplexed readout with high position resolution for positron emission tomography

    NASA Astrophysics Data System (ADS)

    Lee, Sangwon; Choi, Yong; Kang, Jihoon; Jung, Jin Ho

    2017-04-01

    Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high-resolution PET detector block composed of 2×3 detector modules, each consisting of an 8×8 array of 1.52×1.52×6 mm3 LYSO, a 4×4 array of 3×3 mm2 silicon photomultiplier (SiPM) and 13.4×13.4 mm2 light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7±1.6% full-width-at-half-maximum (FWHM) and the peak-to-valley ratios of the flood histogram on the horizontal and vertical lines were 18.8±0.8 and 22.8±1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 mm could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

  19. Detection of occult disease in breast cancer using fluorodeoxyglucose camera-based positron emission tomography.

    PubMed

    Pecking, A P; Mechelany-Corone, C; Bertrand-Kermorgant, F; Alberini, J L; Floiras, J L; Goupil, A; Pichon, M F

    2001-10-01

    An isolated increase of blood tumor marker CA 15.3 in breast cancer is considered a sensitive indicator for occult metastatic disease but by itself is not sufficient for initiating therapeutic intervention. We investigated the potential of camera-based positron emission tomography (PET) imaging using [18F]-fluorodeoxyglucose (FDG) to detect clinically occult recurrences in 132 female patients (age, 35-69 years) treated for breast cancer, all presenting with an isolated increase in blood tumor marker CA 15.3 without any other evidence of metastatic disease. FDG results were correlated to pathology results or to a sequentially guided conventional imaging method. One hundred nineteen patients were eligible for correlations. Positive FDG scans were obtained for 106 patients, including 89 with a single lesion and 17 with 2 or more lesion. There were 92 true-positive and 14 false-positive cases, 10 of which became true positive within 1 year. Among the 13 negative cases, 7 were false negative and 6 were true negative. Camera-based PET using FDG has successfully identified clinically occult disease with an overall sensitivity of 93.6% and a positive predictive value of 96.2%. The smallest detected size was 6 mm for a lymph node metastasis (tumor to nontumor ratio, 4:2). FDG camera-based PET localized tumors in 85.7% of cases suspected for clinically occult metastatic disease on the basis of a significant increase in blood tumor marker. A positive FDG scan associated with an elevated CA 15.3 level is most consistent with metastatic relapse of breast cancer.

  20. Patient self-attenuation and technologist dose in positron emission tomography

    SciTech Connect

    Zeff, Benjamin W.; Yester, Michael V.

    2005-04-01

    Positron emission tomography (PET), with 511-keV radiation and long patient-uptake times, presents unique radiation safety concerns. This two-part study considers aspects of PET radiation safety as they relate to PET suite design, dose to the public, and technologist occupational dose. In the first part of the study, the self-attenuation of radiation by patients' bodies was quantified. The radiation exposure was measured at three positions from 64 patients injected with fluorine-18 fluorodeoxyglucose (FDG) during the uptake period. Compared with an in vitro control used as a point source, a significant decrease in exposure (>40% at 1 m) was observed due to nonuniform distribution of FDG and attenuation within the patients. The attenuation data are consistent with results from simulations [M. E. Phelps, ''Comments and Perspectives,'' J. Nucl. Med. 45, 1601 (2004)] that treat the body as a uniform, water-filled cylinder. As distance is often the principal source of protection for 511-keV radiation, the considerable self-attenuation may allow for more compact PET suites. However, despite high patient self-attenuation, shielding, and standard precautionary measures, PET technologist occupational doses can remain quite high ({approx}12 mSv/year). The second part of this study tracked the daily dose received by PET technologists. Close technologist-patient interaction both during and following FDG administration, as much as 20 min/study, contribute to the high doses and point to the need for a more innovative approach to radiation protection for PET technologists.

  1. What have positron emission tomography and 'Zippy' told us about the neuropharmacology of drug addiction?

    PubMed

    Cumming, Paul; Caprioli, Daniele; Dalley, Jeffrey W

    2011-08-01

    Translational molecular imaging with positron emission tomography (PET) and allied technologies offer unrivalled applications in the discovery of biomarkers and aetiological mechanisms relevant to human disease. Foremost among clinical PET findings during the past two decades of addiction research is the seminal discovery of reduced dopamine D(2/3) receptor expression in the striatum of drug addicts, which could indicate a predisposing factor and/or compensatory reaction to the chronic abuse of stimulant drugs. In parallel, recent years have witnessed significant improvements in the performance of small animal tomographs (microPET) and a refinement of animal models of addiction based on clinically relevant diagnostic criteria. This review surveys the utility of PET in the elucidation of neuropharmacological mechanisms underlying drug addiction. It considers the consequences of chronic drug exposure on regional brain metabolism and neurotransmitter function and identifies those areas where further research is needed, especially concerning the implementation of PET tracers targeting neurotransmitter systems other than dopamine, which increasingly have been implicated in the pathophysiology of drug addiction. In addition, this review considers the causal effects of behavioural traits such as impulsivity and novelty/sensation-seeking on the emergence of compulsive drug-taking. Previous research indicates that spontaneously high-impulsive rats--as exemplified by 'Zippy'--are pre-disposed to escalate intravenous cocaine self-administration, and subsequently to develop compulsive drug taking tendencies that endure despite concurrent adverse consequences of such behaviour, just as in human addiction. The discovery using microPET of pre-existing differences in dopamine D(2/3) receptor expression in the striatum of high-impulsive rats suggests a neural endophenotype that may likewise pre-dispose to stimulant addiction in humans.

  2. Positron emission tomography in the follow-up of cutaneous malignant melanoma patients: a systematic review

    PubMed Central

    Danielsen, Maria; Højgaard, Liselotte; Kjær, Andreas; Fischer, Barbara MB

    2014-01-01

    Cutaneous malignant melanoma (CMM) has a high risk of dissemination to regional lymph nodes and visceral organs. Recurrences are most frequently seen within the first 2-3 years after initial treatment, but these patients have a life-long risk of relapse. The prognosis is highly dependent on lymph node involvement and distant metastases, accentuating the importance of close surveillance to identify disease progression at an early stage, and thereby detect recurrences amenable to treatment. Positron emission tomography (PET) has already been proven useful in the staging of CMM, but the utility of PET in follow-up programs for asymptomatic patients in high risk of relapse to detect systemic recurrences has yet to be investigated. We performed a systematic literature search in PUBMED, EMBASE and the Cochrane Controlled Trials Register, and identified 7 original studies on the diagnostic value of FDG-PET in the follow-up of CMM. Sensitivity, specificity, positive and negative predictive values were calculated to examine PET’s diagnostic value in detecting relapse. The mean sensitivity of PET was 96% and the specificity was 92%. The positive and negative predictive values were, respectively, 92% and 95%. Overall, PET has a high diagnostic value and the many advantages of PET indicate utility in the routine follow-up program of CMM. However, the number of prospective studies of high quality is scarce, and as the use of PET and PET/CT is becoming more widespread and the technology is expensive, there is an urgent need for systematic assessment of the diagnostic value. PMID:24380042

  3. Theory of Mind and Schizophrenia: A Positron Emission Tomography Study of Medication-Free Patients

    PubMed Central

    Andreasen, Nancy C.; Calage, Chadi A.; O'Leary, Daniel S.

    2008-01-01

    Background: “Theory of mind” (TOM) refers to the ability to attribute mental states (ie, beliefs and goals) to one's self and others and to recognize that behaviors are guided by these mental states. This capacity, critical for social competence, is impaired in schizophrenia. We undertook a study of TOM in a group of patients with schizophrenia and healthy controls. Method: We used positron emission tomography to identify the neural circuits recruited during a verbal task that required participants to attribute mental states to a character in a story of their creation. The comparison task consisted of reading aloud a neutral story, controlling for the speech component of the task. Results: Patients and controls generated the same percentage of TOM utterances. However, the two groups had markedly different patterns of brain activation. Compared with controls, patients had a lower blood flow in multiple regions in the left hemisphere including the frontal and visual association cortices, posterior hippocampus, and insula. The flow was also lower in contralateral areas in the lateral cerebellum and vermis, thalamus, and posterior insula. On the other hand, the flow was higher in the patients predominantly in the right hemisphere, including multiple frontal and parietal regions, insula, visual association cortex, and pulvinar. Discussion: The areas of lower flow are consistent with previous studies indicating impairment in recruiting cortical-cerebellar circuitry in schizophrenia. The areas of higher flow may reflect a need to draw on the right hemisphere to compensate for deficits in left hemisphere networks that include frontal cortex, anterior cingulate, cerebellum, and thalamus. PMID:18559406

  4. Crystal identification in positron emission tomography using nonrigid registration to a Fourier-based template

    PubMed Central

    Chaudhari, Abhijit J.; Joshi, Anand A.; Bowen, Spencer L.; Leahy, Richard M.; Cherry, Simon R.; Badawi, Ramsey D.

    2009-01-01

    Modern Positron Emission Tomography (PET) detectors typically are made from 2D modular arrays of scintillation crystals. Their characteristic flood field response (or flood histogram) must be segmented in order to correctly determine the crystal of annihilation photon interaction in the system. Crystal identification information thus generated is also needed for accurate system modeling as well as for detailed detector characterization and performance studies. In this paper, we present a semi-automatic general purpose template-guided scheme for segmentation of flood histograms. We first generate a template image that exploits the spatial frequency information in the given flood histogram using Fourier-space analysis. This template image is a lower order approximation of the flood histogram, and can be segmented with horizontal and vertical lines drawn midway between adjacent peaks in the histogram. The template is then registered to the given flood histogram by a diffeomorphic polynomial-based warping scheme that is capable of iteratively minimizing intensity differences. The displacement field thus calculated is applied to the segmentation of the template resulting in a segmentation of the given flood histogram. We evaluate our segmentation scheme for a photomultiplier tube-based PET detector, a detector with readout by a position-sensitive avalanche photodiode (PSAPD) and a detector consisting of a stack of photomultiplier tubes and scintillator arrays. Further, we quantitatively compare the performance of the proposed method to that of a manual segmentation scheme using reconstructed images of a line source phantom. We also present an adaptive method for distortion reduction in flood histograms obtained for PET detectors that use PSAPDs. PMID:18723924

  5. Autoradiography screening of potential positron emission tomography tracers for asymptomatic abdominal aortic aneurysms

    PubMed Central

    Estrada, Sergio; Hall, Håkan; Wanhainen, Anders; Björck, Martin; Sörensen, Jens; Antoni, Gunnar

    2014-01-01

    Objective The aetiology and early pathophysiological mechanisms of aortic aneurysm formation are still unknown and challenging to study in vivo. Positron emission tomography (PET) is a potentially valuable instrument for non-invasive in vivo pathophysiological studies. No specific tracer to identify the pathophysiological process of aneurysmal dilatation is yet available, however. The aim of this study was to explore if different PET tracers could be useful to image aneurysmal disease. Methods and results Human aneurysmal aortic tissue, collected during elective resection of abdominal aortic aneurysm (AAA) of asymptomatic patients, was investigated in vitro by means of autoradiography with [68Ga]CRP-binder targeting C-reactive protein, [11C]DAA1106 targeting translocator protein (18 kDa), [11C]D-deprenyl with unknown target receptor, [11C]deuterium-L-deprenyl targeting astrocytes, [18F]fluciclatide targeting integrin αVβ3, [68Ga]IMP461 and bi-specific antibody TF2 052107 targeting carcinoembryonic antigen, [18F]F-metomidate targeting mitochondrial cytochrome P-450 species in the adrenal cortex, and [18F]vorozole targeting aromatase. Of the investigated tracers, only [18F]fluciclatide exhibited specific binding, whereas the other PET tracers failed to show specific uptake in the investigated tissue and are probably not useful for the intended purpose. Conclusion It seems likely that αVβ3 integrin expression in AAA can be visualized with PET and that the αVβ3 selective tracer, [18F]fluciclatide, may be suitable for in vivo molecular imaging of asymptomatic AAA. Additional evaluation of [18F]fluciclatide and αVβ3 integrin expression in AAA will be performed in vitro as well as in vivo. PMID:24555564

  6. Positron Emission Tomography Reporter Genes and Reporter Probes: Gene and Cell Therapy Applications

    PubMed Central

    Yaghoubi, Shahriar S.; Campbell, Dean O.; Radu, Caius G.; Czernin, Johannes

    2012-01-01

    Positron emission tomography (PET) imaging reporter genes (IRGs) and PET reporter probes (PRPs) are amongst the most valuable tools for gene and cell therapy. PET IRGs/PRPs can be used to non-invasively monitor all aspects of the kinetics of therapeutic transgenes and cells in all types of living mammals. This technology is generalizable and can allow long-term kinetics monitoring. In gene therapy, PET IRGs/PRPs can be used for whole-body imaging of therapeutic transgene expression, monitoring variations in the magnitude of transgene expression over time. In cell or cellular gene therapy, PET IRGs/PRPs can be used for whole-body monitoring of therapeutic cell locations, quantity at all locations, survival and proliferation over time and also possibly changes in characteristics or function over time. In this review, we have classified PET IRGs/PRPs into two groups based on the source from which they were derived: human or non-human. This classification addresses the important concern of potential immunogenicity in humans, which is important for expansion of PET IRG imaging in clinical trials. We have then discussed the application of this technology in gene/cell therapy and described its use in these fields, including a summary of using PET IRGs/PRPs in gene and cell therapy clinical trials. This review concludes with a discussion of the future direction of PET IRGs/PRPs and recommends cell and gene therapists collaborate with molecular imaging experts early in their investigations to choose a PET IRG/PRP system suitable for progression into clinical trials. PMID:22509201

  7. Accurate Automatic Delineation of Heterogeneous Functional Volumes in Positron Emission Tomography for Oncology Applications

    SciTech Connect

    Hatt, Mathieu; Cheze le Rest, Catherine; Descourt, Patrice; Dekker, Andre; De Ruysscher, Dirk; Oellers, Michel; Lambin, Philippe; Pradier, Olivier; Visvikis, Dimitris

    2010-05-01

    Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.

  8. Digital contrast enhancement of 18Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma

    PubMed Central

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    Purpose: The role of 18fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. Materials and Methods: A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold “m” and slope “e”). The input parameters which resulted in an image having a high value of 2nd order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. Results: The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters “m” had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope “e” was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. Conclusion: The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted. PMID:26917889

  9. Assessment of myocardial oxidative metabolic reserve with positron emission tomography and carbon-11 acetate

    SciTech Connect

    Henes, C.G.; Bergmann, S.R.; Walsh, M.N.; Sobel, B.E.; Geltman, E.M. )

    1989-09-01

    We have previously demonstrated that positron emission tomography (PET) with ({sup 11}C)acetate allows noninvasive regional quantification of myocardial oxidative metabolism. To assess the metabolic response of normal myocardium to increased work (oxidative metabolic reserve), clearance of myocardial {sup 11}C activity after administration of ({sup 11}C)acetate i.v. was measured with PET in seven normal subjects at rest and during dobutamine infusion. At rest, clearance of {sup 11}C was monoexponential and homogeneous. The rate constant of the first phase of {sup 11}C clearance, k1, averaged 0.054 {plus minus} 0.014 min-1 at a rate-pressure produce (RPP) of 7329 {plus minus} 1445 mmHg X bpm. During dobutamine infusion, RPP increased by an average of 141% to 17,493 {plus minus} 3582 mm Hg Z bpm. Clearance of 11C became biexponential and remained homogeneous. k1 averaged 0.198 {plus minus} 0.043 min-1 with a mean coefficient of variation of 16%.. k1 and RPP correlated closely (r = 0.91; p less than 0.001), and the slope of the k1/RPP relation remained consistent in all subjects (1.48 {plus minus} 0.42). These findings suggest that PET with ({sup 11}C)acetate and dobutamine stress may provide a promising approach for evaluation of regional myocardial oxidative metabolic reserve in patients with cardiac diseases of diverse etiologies and for assessment of the efficacy of interventions designed to enhance the recovery of metabolically comprised myocardium.

  10. Positron Emission Tomography (PET) Evaluation After Initial Chemotherapy and Radiation Therapy Predicts Local Control in Rhabdomyosarcoma

    SciTech Connect

    Dharmarajan, Kavita V.; Wexler, Leonard H.; Gavane, Somali; Fox, Josef J.; Schoder, Heiko; Tom, Ashlyn K.; Price, Alison N.; Meyers, Paul A.; Wolden, Suzanne L.

    2012-11-15

    Purpose: 18-fluorodeoxyglucose positron emission tomography (PET) is already an integral part of staging in rhabdomyosarcoma. We investigated whether primary-site treatment response characterized by serial PET imaging at specific time points can be correlated with local control. Patients and Methods: We retrospectively examined 94 patients with rhabdomyosarcoma who received initial chemotherapy 15 weeks (median) before radiotherapy and underwent baseline, preradiation, and postradiation PET. Baseline PET standardized uptake values (SUVmax) and the presence or absence of abnormal uptake (termed PET-positive or PET-negative) both before and after radiation were examined for the primary site. Local relapse-free survival (LRFS) was calculated according to baseline SUVmax, PET-positive status, and PET-negative status by the Kaplan-Meier method, and comparisons were tested with the log-rank test. Results: The median patient age was 11 years. With 3-year median follow-up, LRFS was improved among postradiation PET-negative vs PET-positive patients: 94% vs 75%, P=.02. By contrast, on baseline PET, LRFS was not significantly different for primary-site SUVmax {<=}7 vs >7 (median), although the findings suggested a trend toward improved LRFS: 96% for SUVmax {<=}7 vs 79% for SUVmax >7, P=.08. Preradiation PET also suggested a statistically insignificant trend toward improved LRFS for PET-negative (97%) vs PET-positive (81%) patients (P=.06). Conclusion: Negative postradiation PET predicted improved LRFS. Notably, 77% of patients with persistent postradiation uptake did not experience local failure, suggesting that these patients could be closely followed up rather than immediately referred for intervention. Negative baseline and preradiation PET findings suggested statistically insignificant trends toward improved LRFS. Additional study may further understanding of relationships between PET findings at these time points and outcome in rhabdomyosarcoma.

  11. A practical guide to the construction of radiometallated bioconjugates for positron emission tomography

    PubMed Central

    Zeglis, Brian M.

    2013-01-01

    Positron emission tomography (PET) has become a vital imaging modality in the diagnosis and treatment of disease, most notably cancer. A wide array of small molecule PET radiotracers have been developed that employ the short half-life radionuclides 11C, 13N, 15O, and 18F. However, PET radiopharmaceuticals based on biomolecular targeting vectors have been the subject of dramatically increased research in both the laboratory and the clinic. Typically based on antibodies, oligopeptides, or oligonucleotides, these tracers have longer biological half-lives than their small molecule counterparts and thus require labeling with radionuclides with longer, complementary radioactive half-lives, such as the metallic isotopes 64Cu, 68Ga, 86Y, and 89Zr. Each bioconjugate radiopharmaceutical has four component parts: biomolecular vector, radiometal, chelator, and covalent link between chelator and biomolecule. With the exception of the radiometal, a tremendous variety of choices exists for each of these pieces, and a plethora of different chelation, conjugation, and radiometallation strategies have been utilized to create agents ranging from 68Ga-labeled pentapeptides to 89Zr-labeled monoclonal antibodies. Herein, the authors present a practical guide to the construction of radiometal-based PET bioconjugates, in which the design choices and synthetic details of a wide range of biomolecular tracers from the literature are collected in a single reference. In assembling this information, the authors hope both to illuminate the diverse methods employed in the synthesis of these agents and also to create a useful reference for molecular imaging researchers both experienced and new to the field. PMID:21442098

  12. Imaging Enterobacteriaceae infection in vivo with 18F-fluorodeoxysorbitol positron emission tomography

    PubMed Central

    Weinstein, Edward A.; Ordonez, Alvaro A.; DeMarco, Vincent P.; Murawski, Allison M.; Pokkali, Supriya; MacDonald, Elizabeth M.; Klunk, Mariah; Mease, Ronnie C.; Pomper, Martin G.; Jain, Sanjay K.

    2015-01-01

    The Enterobacteriaceae are a family of rod-shaped Gram-negative bacteria that normally inhabit the gastrointestinal tract and are the most common cause of Gram-negative bacterial infections in humans. In addition to causing serious multidrug-resistant, hospital-acquired infections, a number of Enterobacteriaceae species are also recognized as biothreat pathogens. As a consequence, new tools are urgently needed to specifically identify and localize infections due to Enterobacteriaceae and to monitor antimicrobial efficacy. In this report, we used commercially available 2-[18F]-fluorodeoxyglucose (18F-FDG) to produce 2-[18F]-fluorodeoxysorbitol (18F-FDS), a radioactive probe for Enterobacteriaceae, in 30 min. 18F-FDS selectively accumulated in Enterobacteriaceae, but not in Gram-positive bacteria or healthy mammalian or cancer cells in vitro. In a murine myositis model, 18F-FDS positron emission tomography (PET) rapidly differentiated true infection from sterile inflammation with a limit of detection of 6.2 ± 0.2 log10 colony-forming units (CFU) for Escherichia coli. Our findings were extended to models of mixed Gram-positive and Gram-negative thigh co-infections, brain infection, Klebsiella pneumonia, and mice undergoing immunosuppressive chemotherapy. This technique rapidly and specifically localized infections due to Enterobacteriaceae, providing a three-dimensional holistic view within the animal. Last, 18F-FDS PET monitored the efficacy of antimicrobial treatment, demonstrating a PET signal proportionate to the bacterial burden. Therapeutic failures associated with multidrug-resistant, extended-spectrum β-lactamase (ESBL)–producing E. coli infections were detected in real time. Together, these data show that 18F-FDS is a candidate imaging probe for translation to human clinical cases of known or suspected infections owing to Enterobacteriaceae. PMID:25338757

  13. A Bayesian spatial temporal mixtures approach to kinetic parametric images in dynamic positron emission tomography

    PubMed Central

    Zhu, W.; Ouyang, J.; Rakvongthai, Y.; Guehl, N. J.; Wooten, D. W.; El Fakhri, G.; Normandin, M. D.; Fan, Y.

    2016-01-01

    Purpose: Estimation of parametric maps is challenging for kinetic models in dynamic positron emission tomography. Since voxel kinetics tend to be spatially contiguous, the authors consider groups of homogeneous voxels together. The authors propose a novel algorithm to identify the groups and estimate kinetic parameters simultaneously. Uncertainty estimates for kinetic parameters are also obtained. Methods: Mixture models were used to fit the time activity curves. In order to borrow information from spatially nearby voxels, the Potts model was adopted. A spatial temporal model was built incorporating both spatial and temporal information in the data. Markov chain Monte Carlo was used to carry out parameter estimation. Evaluation and comparisons with existing methods were carried out on cardiac studies using both simulated data sets and a pig study data. One-compartment kinetic modeling was used, in which K1 is the parameter of interest, providing a measure of local perfusion. Results: Based on simulation experiments, the median standard deviation across all image voxels, of K1 estimates were 0, 0.13, and 0.16 for the proposed spatial mixture models (SMMs), standard curve fitting, and spatial K-means methods, respectively. The corresponding median mean squared biases for K1 were 0.04, 0.06, and 0.06 for abnormal region of interest (ROI); 0.03, 0.03, and 0.04 for normal ROI; and 0.007, 0.02, and 0.05 for the noise region. Conclusions: SMM is a fully Bayesian algorithm which determines the optimal number of homogeneous voxel groups, voxel group membership, parameter estimation, and parameter uncertainty estimation simultaneously. The voxel membership can also be used for classification purposes. By borrowing information from spatially nearby voxels, SMM substantially reduces the variability of parameter estimates. In some ROIs, SMM also reduces mean squared bias. PMID:26936707

  14. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    SciTech Connect

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  15. PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography

    NASA Astrophysics Data System (ADS)

    Thomas, Benjamin A.; Cuplov, Vesna; Bousse, Alexandre; Mendes, Adriana; Thielemans, Kris; Hutton, Brian F.; Erlandsson, Kjell

    2016-11-01

    Positron emission tomography (PET) images are degraded by a phenomenon known as the partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically through the utilisation of structural information provided by other imaging modalities such as MRI or CT. These methods, known as partial volume correction (PVC) techniques, reduce PVEs by compensating for the effects of the scanner resolution, thereby improving the quantitative accuracy. The PETPVC toolbox described in this paper comprises a suite of methods, both classic and more recent approaches, for the purposes of applying PVC to PET data. Eight core PVC techniques are available. These core methods can be combined to create a total of 22 different PVC techniques. Simulated brain PET data are used to demonstrate the utility of toolbox in idealised conditions, the effects of applying PVC with mismatched point-spread function (PSF) estimates and the potential of novel hybrid PVC methods to improve the quantification of lesions. All anatomy-based PVC techniques achieve complete recovery of the PET signal in cortical grey matter (GM) when performed in idealised conditions. Applying deconvolution-based approaches results in incomplete recovery due to premature termination of the iterative process. PVC techniques are sensitive to PSF mismatch, causing a bias of up to 16.7% in GM recovery when over-estimating the PSF by 3 mm. The recovery of both GM and a simulated lesion was improved by combining two PVC techniques together. The PETPVC toolbox has been written in C++, supports Windows, Mac and Linux operating systems, is open-source and publicly available.

  16. Determination of elemental tissue composition following proton treatment using positron emission tomography

    NASA Astrophysics Data System (ADS)

    Cho, Jongmin; Ibbott, Geoffrey; Gillin, Michael; Gonzalez-Lepera, Carlos; Min, Chul Hee; Zhu, Xuping; El Fakhri, Georges; Paganetti, Harald; Mawlawi, Osama

    2013-06-01

    Positron emission tomography (PET) has been suggested as an imaging technique for in vivo proton dose and range verification after proton induced-tissue activation. During proton treatment, irradiated tissue is activated and decays while emitting positrons. In this paper, we assessed the feasibility of using PET imaging after proton treatment to determine tissue elemental composition by evaluating the resultant composite decay curve of activated tissue. A phantom consisting of sections composed of different combinations of 1H, 12C, 14N, and 16O was irradiated using a pristine Bragg peak and a 6 cm spread-out Bragg-peak (SOBP) proton beam. The beam ranges defined at 90% distal dose were 10 cm the delivered dose was 1.6 Gy for the near monoenergetic beam and 2 Gy for the SOBP beam. After irradiation, activated phantom decay was measured using an in-room PET scanner for 30 min in list mode. Decay curves from the activated 12C and 16O sections were first decomposed into multiple simple exponential decay curves, each curve corresponding to a constituent radioisotope, using a least-squares method. The relative radioisotope fractions from each section were determined. These fractions were used to guide the decay curve decomposition from the section consisting mainly of 12C + 16O and calculate the relative elemental composition of 12C and 16O. A Monte Carlo simulation was also used to determine the elemental composition of the 12C + 16O section. The calculated compositions of the 12C + 16O section using both approaches (PET and Monte Carlo) were compared with the true known phantom composition. Finally, two patients were imaged using an in-room PET scanner after proton therapy of the head. Their PET data and the technique described above were used to construct elemental composition (12C and 16O) maps that corresponded to the proton-activated regions. We compared the 12C and 16O compositions of seven ROIs that corresponded to the vitreous humor, adipose/face mask, adipose

  17. Progressive failure of coronary flow during reperfusion of myocardial infarction: Documentation of the no reflow phenomenon with positron emission tomography

    SciTech Connect

    Jeremy, R.W.; Links, J.M.; Becker, L.C. )

    1990-09-01

    During reperfusion of a myocardial infarct, development of microvascular occlusion may result in regional hypoperfusion (no reflow) despite a patent infarct-related artery. This study examined the extent and time course of no reflow with use of rubidium-82 positron emission tomography. In 12 anesthetized dogs, the left anterior descending coronary artery was occluded for 90 min and then freely reperfused. Regional myocardial perfusion was imaged by serial rubidium-82 positron emission tomography during coronary occlusion and every 30 min during reperfusion. After 4 h of reperfusion, infarct size and no reflow zone were measured postmortem by triphenyltetrazolium and thioflavin staining, respectively. Perfusion defects evident on rubidium-82 images during coronary occlusion rapidly resolved during the early reflow period. However, a recurrent perfusion defect appeared after 1 to 2 h of reflow in all dogs. The severity of recurrent perfusion defects progressed with time; after 5 min of reflow, relative perfusion in the left anterior descending artery territory was 97 +/- 6% of that in the normal circumflex artery region, but perfusion decreased progressively to 68 +/- 5% after 2 h (p less than 0.05) and to 55 +/- 4% after 4 h of reperfusion (p less than 0.05 versus 2 h). As measured by radioactive tracer microspheres, endocardial blood flow decreased similarly in the postischemic left anterior descending artery region from 1.2 +/- 0.2 ml/min per g after 5 min of reflow to 0.4 +/- 0.1 ml/min per g after 3 h of reflow (p less than 0.01). Residual infarct perfusion, measured by rubidium-82 after 4 h of reflow, was related to both infarct size (r = -0.88) and the extent of the no reflow zone (r = -0.84) in the postmortem left ventricular sections. Thus, serial positron emission tomography with rubidium-82 demonstrates a progressive loss of infarct perfusion.

  18. Correlation of PUV and SUV in the Extremities while using PEM as a High Resolution Positron Emission Scanner

    PubMed Central

    Rahim, Sania; Mawlawi, Osama; Fox, Patricia; Taylor, Shree; Millican, Richelle; Swanston, Nancy M.; Brown, Elliott; Rohren, Eric M.

    2014-01-01

    Intro Due to its unique configuration of two adjustable plate detectors Positron Emission Mammography, or PEM, could theoretically also function as a high resolution positron emission scanner for the extremities or neck. PEM quantitates its activity via a “PEM Uptake Value,” or PUV, and although its relationship to the Standardized Uptake Value, or SUV, has been demonstrated in the breasts, to our knowledge there are no studies validating PUV in other sites such as the extremities. Materials/Methods Thi s was a retrospective chart review of two separate protocols of a total of 15 patients. The patients all had hypermetabolic lesions in the extremities or neck on imaging with PET/CT and were sent after their PET/CT to PEM for further imaging. Due to the se quential nature of these exams no additional radiotracer was administered. Results A spearman rank order correlation was calculated between the PUV max obtained from PEM images, and the SUVmax for all. The spearman rank order correlation for all sites wa s 0.42 which is not significantly different from 0 (p=0.13). When neck lesions were excluded from the group, there was a strong and statistically significant correlation between PUVmax and SUVmax, with a spearman rank correlation of 0.73 and significantly different from 0 (p=0.0068). Discussion The correlation of PUV and SUV in the extremities indicates the potential use of PEM as a semiquantitative, high resolution positron emission scanner and warrants further investigation especially in the realm of dis ease processes that often present in the extremities such as melanoma, osteomyelitis and arthritis as well as playing a role in the imaging of patients with metallic hardware post limb salvage surgery. PMID:24430256

  19. Positron Emission Tomography-Guided, Focal-Dose Escalation Using Intensity-Modulated Radiotherapy for Head and Neck Cancer

    SciTech Connect

    Madani, Indira . E-mail: indira@krtkg1.ugent.be; Duthoy, Wim; Derie, Cristina R.N.; De Gersem, Werner Ir.; Boterberg, Tom; Saerens, Micky; Jacobs, Filip Ir.; Gregoire, Vincent; Lonneux, Max; Vakaet, Luc; Vanderstraeten, Barbara; Bauters, Wouter; Bonte, Katrien; Thierens, Hubert; Neve, Wilfried de

    2007-05-01

    Purpose: To assess the feasibility of intensity-modulated radiotherapy (IMRT) using positron emission tomography (PET)-guided dose escalation, and to determine the maximum tolerated dose in head and neck cancer. Methods and Materials: A Phase I clinical trial was designed to escalate the dose limited to the [{sup 18}-F]fluoro-2-deoxy-D-glucose positron emission tomography ({sup 18}F-FDG-PET)-delineated subvolume within the gross tumor volume. Positron emission tomography scanning was performed in the treatment position. Intensity-modulated radiotherapy with an upfront simultaneously integrated boost was employed. Two dose levels were planned: 25 Gy (level I) and 30 Gy (level II), delivered in 10 fractions. Standard IMRT was applied for the remaining 22 fractions of 2.16 Gy. Results: Between 2003 and 2005, 41 patients were enrolled, with 23 at dose level I, and 18 at dose level II; 39 patients completed the planned therapy. The median follow-up for surviving patients was 14 months. Two cases of dose-limiting toxicity occurred at dose level I (Grade 4 dermitis and Grade 4 dysphagia). One treatment-related death at dose level II halted the study. Complete response was observed in 18 of 21 (86%) and 13 of 16 (81%) evaluated patients at dose levels I and II (p < 0.7), respectively, with actuarial 1-year local control at 85% and 87% (p n.s.), and 1-year overall survival at 82% and 54% (p = 0.06), at dose levels I and II, respectively. In 4 of 9 patients, the site of relapse was in the boosted {sup 18}F-FDG-PET-delineated region. Conclusions: For head and neck cancer, PET-guided dose escalation appears to be well-tolerated. The maximum tolerated dose was not reached at the investigated dose levels.

  20. High resolution gamma detector for small-animal positron emission tomography

    NASA Astrophysics Data System (ADS)

    Ling, Tao

    In this study, the performance of continuous miniature crystal element (cMiCE) detectors with LYSO crystals of different thickness were investigated. Potential designs of a cMiCE small animal positron emission tomography scanner were also evaluated by an analytical simulation approach. The cMiCE detector was proposed as a high sensitivity, low cost alternative to the prevailing discrete crystal detectors. A statistics based positioning (SBP) algorithm was developed to solve the scintillation position estimation problem and proved to be successful on a cMiCE detector with a 4 mm thick crystal. By assuming a Gaussian distribution, the distributions of the photomultiplier signals could be characterized by mean and variance, which are functions of scintillation position. After calibrating the detector on a grid of locations, a 2D table of the mean and variance can be built. The SBP algorithm searches the tables to find the location that maximizes the likelihood between the mean and variance of known positions and the incoming scintillation event. In this work, the performance of the SBP algorithm on cMiCE detectors with thicker crystals (6 and 8 mm) was studied. The stopping power of a cMiCE detector is 40% and 49% for 6 and 8 mm thick crystals respectively. The intrinsic spatial resolution is 1.2 mm and 1.4 mm FWHM for the center and corner sections of a 6 mm thick crystal detector, and 1.3 mm and 1.6 mm for center and corner of an 8 mm thick crystal detector. These results demonstrate that the cMiCE detector is a promising candidate for high resolution, high sensitivity PET applications. A maximum-likelihood (ML) clustering method was developed to empirically separate the experimental data set into two to four subgroups according to the depth-of-interaction of the detected photons. This method enabled us to build 2-DOI lookup tables (LUT) (mean and variance lookup tables for front group and back group). Using the 2-DOI SBP LUTs, the scintillation position and DOI

  1. Role of 18F-fluorodeoxyglucose positron emission tomography imaging in surgery for pancreatic cancer

    PubMed Central

    Wakabayashi, Hisao; Nishiyama, Yoshihiro; Otani, Tsuyoshi; Sano, Takanori; Yachida, Shinichi; Okano, Keiichi; Izuishi, Kunihiko; Suzuki, Yasuyuki

    2008-01-01

    AIM: To evaluate the role of positron emission tomo-graphy using 18F-fluorodeoxyglucose (FDG-PET) in the surgical management of patients with pancreatic cancer, including the diagnosis, staging, and selection of patients for the subsequent surgical treatment. METHODS: This study involved 53 patients with proven primary pancreatic cancer. The sensitivity of diagnosing the primary cancer was examined for FDG-PET, CT, cytological examination of the bile or pancreatic juice, and the serum levels of carcinoembrionic antigens (CEA) and carbohydrate antigen 19-9 (CA19-9). Next, the accuracy of staging was compared between FDG-PET and CT. Finally, FDG-PET was analyzed semiquantitatively using the standard uptake value (SUV). The impact of the SUV on patient management was evaluated by examining the correlations between the SUV and the histological findings of cancer. RESULTS: The sensitivity of FDG-PET, CT, cytological examination of the bile or pancreatic juice, and the serum levels of CEA and CA19-9 were 92.5%, 88.7%, 46.4%, 37.7% and 69.8%, respectively. In staging, FDG-PET was superior to CT only in diagnosing distant disease (bone metastasis). For local staging, the sensitivity of CT was better than that of FDG-PET. The SUV did not correlate with the pTNM stage, grades, invasions to the vessels and nerve, or with the size of the tumor. However, there was a statistically significant difference (4.6 ± 2.9 vs 7.8 ± 4.5, P = 0.024) in the SUV between patients with respectable and unresectable disease. CONCLUSION: FDG-PET is thus considered to be useful in the diagnosis of pancreatic cancer. However, regarding the staging of the disease, FDG-PET is not considered to be a sufficiently accurate diagnostic modality. Although the SUV does not correlate with the patho-histological prognostic factors, it may be useful in selecting patients who should undergo subsequent surgical treatment. PMID:18176963

  2. A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography.

    PubMed

    Aristophanous, Michalis; Penney, Bill C; Martel, Mary K; Pelizzari, Charles A

    2007-11-01

    The increased interest in 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an "analysis region" to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the

  3. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    SciTech Connect

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET

  4. Fluorodeoxyglucose Positron Emission Tomography Response and Normal Tissue Regeneration After Stereotactic Body Radiotherapy to Liver Metastases

    SciTech Connect

    Stinauer, Michelle A.; Diot, Quentin; Westerly, David C.; Schefter, Tracey E.; Kavanagh, Brian D.

    2012-08-01

    Purpose: To characterize changes in standardized uptake value (SUV) in positron emission tomography (PET) scans and determine the pace of normal tissue regeneration after stereotactic body radiation therapy (SBRT) for solid tumor liver metastases. Methods and Materials: We reviewed records of patients with liver metastases treated with SBRT to {>=}40 Gy in 3-5 fractions. Evaluable patients had pretreatment PET and {>=}1 post-treatment PET. Each PET/CT scan was fused to the planning computed tomography (CT) scan. The maximum SUV (SUV{sub max}) for each lesion and the total liver volume were measured on each PET/CT scan. Maximum SUV levels before and after SBRT were recorded. Results: Twenty-seven patients with 35 treated liver lesions were studied. The median follow-up was 15.7 months (range, 1.5-38.4 mo), with 5 PET scans per patient (range, 2-14). Exponential decay curve fitting (r=0.97) showed that SUV{sub max} declined to a plateau of 3.1 for controlled lesions at 5 months after SBRT. The estimated SUV{sub max} decay half-time was 2.0 months. The SUV{sub max} in controlled lesions fluctuated up to 4.2 during follow-up and later declined; this level is close to 2 standard deviations above the mean normal liver SUV{sub max} (4.01). A failure cutoff of SUV{sub max} {>=}6 is twice the calculated plateau SUV{sub max} of controlled lesions. Parenchymal liver volume decreased by 20% at 3-6 months and regenerated to a new baseline level approximately 10% below the pretreatment level at 12 months. Conclusions: Maximum SUV decreases over the first months after SBRT to plateau at 3.1, similar to the median SUV{sub max} of normal livers. Transient moderate increases in SUV{sub max} may be observed after SBRT. We propose a cutoff SUV{sub max} {>=}6, twice the baseline normal liver SUV{sub max}, to score local failure by PET criteria. Post-SBRT values between 4 and 6 would be suspicious for local tumor persistence or recurrence. The volume of normal liver reached nadir 3

  5. A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

    SciTech Connect

    Aristophanous, Michalis; Penney, Bill C.; Martel, Mary K.; Pelizzari, Charles A.

    2007-11-15

    The increased interest in {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an 'analysis region' to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of

  6. Postchemoradiotherapy Positron Emission Tomography Predicts Pathologic Response and Survival in Patients With Esophageal Cancer

    SciTech Connect

    Jayachandran, Priya; Pai, Reetesh K.; Quon, Andrew; Graves, Edward; Krakow, Trevor E.; La, Trang; Loo, Billy W.; Koong, Albert C.; Chang, Daniel T.

    2012-10-01

    Purpose: To correlate the prechemoradiotherapy (CRT) and post-CRT metabolic tumor volume (MTV) on positron emission tomography (PET) scanning with the pathologic response and survival in patients receiving preoperative CRT for esophageal cancer. Materials and Methods: The medical records of 37 patients with histologically confirmed Stage I-IVA esophageal cancer treated with CRT with or without surgical resection were reviewed. Of the 37 patients, 21 received preoperative CRT (57%) and 16 received definitive CRT (43%). All patients had a pre-CRT and 32 had a post-CRT PET scan. The MTV was measured on the pre-CRT PET and post-CRT PET scan, respectively, using a minimum standardized uptake value (SUV) threshold x, where x = 2, 2.5, 3, or the SUV maximum Multiplication-Sign 50%. The total glycolytic activity (TGA{sub x}) was defined as the mean SUV Multiplication-Sign MTV{sub x}. The MTV ratio was defined as the pre-CRT PET MTV/post-CRT MTV. The SUV ratio was defined similarly. A single pathologist scored the pathologic response using a tumor regression grade (TRG) scale. Results: The median follow-up was 1.5 years (range, 0.4-4.9). No significant correlation was found between any parameters on the pre-CRT PET scan and the TRG or overall survival (OS). Multiple post-CRT MTV values and post-TGA values correlated with the TRG and OS; however, the MTV{sub 2.5Post} and TGA{sub 2.5Post} had the greatest correlation. The MTV{sub 2} ratio correlated with OS. The maximum SUV on either the pre-CRT and post-CRT PET scans or the maximum SUV ratio did not correlate with the TRG or OS. Patients treated preoperatively had survival similar compared with those treated definitively with a good PET response (p = 0.97) and significantly better than that of patients treated definitively with a poor PET response (p < 0.0001). Conclusion: The maximum SUV was not a predictive or prognostic parameter. The MTV{sub 2.5} and TGA{sub 2.5} were useful markers for predicting the response and

  7. Role of Positron Emission Tomography-Computed Tomography in the Management of Anal Cancer

    SciTech Connect

    Mistrangelo, Massimiliano; Pelosi, Ettore; Bello, Marilena; Ricardi, Umberto; Milanesi, Enrica; Cassoni, Paola; Baccega, Massimo; Filippini, Claudia; Racca, Patrizia; Lesca, Adriana; Munoz, Fernando H.; Fora, Gianluca; Skanjeti, Andrea; Cravero, Francesca; Morino, Mario

    2012-09-01

    Purpose: Pre- and post-treatment staging of anal cancer are often inaccurate. The role of positron emission tomograpy-computed tomography (PET-CT) in anal cancer is yet to be defined. The aim of the study was to compare PET-CT with CT scan, sentinel node biopsy results of inguinal lymph nodes, and anal biopsy results in staging and in follow-up of anal cancer. Methods and Materials: Fifty-three consecutive patients diagnosed with anal cancer underwent PET-CT. Results were compared with computed tomography (CT), performed in 40 patients, and with sentinel node biopsy (SNB) (41 patients) at pretreatment workup. Early follow-up consisted of a digital rectal examination, an anoscopy, a PET-CT scan, and anal biopsies performed at 1 and 3 months after the end of treatment. Data sets were then compared. Results: At pretreatment assessment, anal cancer was identified by PET-CT in 47 patients (88.7%) and by CT in 30 patients (75%). The detection rates rose to 97.9% with PET-CT and to 82.9% with CT (P=.042) when the 5 patients who had undergone surgery prior to this assessment and whose margins were positive at histological examination were censored. Perirectal and/or pelvic nodes were considered metastatic by PET-CT in 14 of 53 patients (26.4%) and by CT in 7 of 40 patients (17.5%). SNB was superior to both PET-CT and CT in detecting inguinal lymph nodes. PET-CT upstaged 37.5% of patients and downstaged 25% of patients. Radiation fields were changed in 12.6% of patients. PET-CT at 3 months was more accurate than PET-CT at 1 month in evaluating outcomes after chemoradiation therapy treatment: sensitivity was 100% vs 66.6%, and specificity was 97.4% vs 92.5%, respectively. Median follow-up was 20.3 months. Conclusions: In this series, PET-CT detected the primary tumor more often than CT. Staging of perirectal/pelvic or inguinal lymph nodes was better with PET-CT. SNB was more accurate in staging inguinal lymph nodes.

  8. The relationship between cerebrospinal fluid markers of Alzheimer pathology and positron emission tomography tau imaging.

    PubMed

    Gordon, Brian A; Friedrichsen, Karl; Brier, Matthew; Blazey, Tyler; Su, Yi; Christensen, Jon; Aldea, Patricia; McConathy, Jonathan; Holtzman, David M; Cairns, Nigel J; Morris, John C; Fagan, Anne M; Ances, Beau M; Benzinger, Tammie L S

    2016-08-01

    The two primary molecular pathologies in Alzheimer's disease are amyloid-β plaques and tau-immunoreactive neurofibrillary tangles. Investigations into these pathologies have been restricted to cerebrospinal fluid assays, and positron emission tomography tracers that can image amyloid-β plaques. Tau tracers have recently been introduced into the field, although the utility of the tracer and its relationship to other Alzheimer biomarkers are still unknown. Here we examined tau deposition in 41 cognitively normal and 11 cognitively impaired older adults using the radioactive tau ligand (18)F-AV-1451 (previously known as T807) who also underwent a lumbar puncture to assess cerebrospinal fluid levels of total tau (t-tau), phosphorylated tau181 (p-tau181) and amyloid-β42 Voxel-wise statistical analyses examined spatial patterns of tau deposition associated with cognitive impairment. We then related the amount of tau tracer uptake to levels of cerebrospinal fluid biomarkers. All analyses controlled for age and gender and, when appropriate, the time between imaging and lumbar puncture assessments. Symptomatic individuals (Clinical Dementia Rating > 0) demonstrated markedly increased levels of tau tracer uptake. This elevation was most prominent in the temporal lobe and temporoparietal junction, but extended more broadly into parietal and frontal cortices. In the entire cohort, there were significant relationships among all cerebrospinal fluid biomarkers and tracer uptake, notably for tau-related cerebrospinal fluid markers. After controlling for levels of amyloid-β42, the correlations with tau uptake were r = 0.490 (P < 0.001) for t-tau and r = 0.492 (P < 0.001) for p-tau181 Within the cognitively normal cohort, levels of amyloid-β42, but not t-tau or p-tau181, were associated with elevated tracer binding that was confined primarily to the medial temporal lobe and adjacent neocortical regions. AV-1451 tau binding in the medial temporal, parietal, and frontal cortices

  9. Effectiveness of positron emission tomography for the detection of melanoma metastases.

    PubMed Central

    Holder, W D; White, R L; Zuger, J H; Easton, E J; Greene, F L

    1998-01-01

    OBJECTIVE: The purpose of this study was to determine the sensitivity, specificity, and clinical utility of 18F 2-fluoro-2-deoxy-D-glucose (FDG) total-body positron emission tomography (PET) scanning for the detection of metastases in patients with malignant melanoma. SUMMARY BACKGROUND DATA: Recent preliminary reports suggest that PET using FDG may be more sensitive and specific for detection of metastatic melanoma than standard radiologic imaging studies using computed tomography (CT). PET technology is showing utility in the detection of metastatic tumors from multiple primary sites including breast, lung, lymphoma, and melanoma. However, little information is available concerning the general utility, sensitivity, and specificity of PET scanning of patients with metastatic melanoma. METHODS: One hundred three PET scans done on 76 nonrandomized patients having AJCC stage II to IV melanoma were prospectively evaluated. Patients were derived from two groups. Group 1 (63 patients) had PET, CT (chest and abdomen), and magnetic resonance imaging (MRI; brain) scans as a part of staging requirements for immunotherapy protocols. Group 2 (13 nonprotocol patients) had PET, CT, and MRI scans as in group 1, but for clinical evaluation only. PET scans were done using 12 to 20 mCi of FDG given intravenously. Results of PET scans were compared to CT scans and biopsy or cytology results. RESULTS: PET scanning for the detection of melanoma metastases had a sensitivity of 94.2% and a specificity of 83.3% compared to 55.3% and 84.4%, respectively, for CT scanning. Factors that produced false-positive PET scans were papillary carcinoma of the thyroid (1), bronchogenic carcinoma (1), inflamed epidermal cyst (1), Warthin's tumor of the parotid gland (1), surgical wound inflammation (2), leiomyoma of the uterus (1), suture granuloma (1), and endometriosis (1). The four false-negative scans were thought to be due to smaller (<0.3 to 0.5 cm) and diffuse areas of melanoma without a mass

  10. Site-Specific Labeling of scVEGF with Fluorine-18 for Positron Emission Tomography Imaging

    PubMed Central

    Wang, Hui; Gao, Haokao; Guo, Ning; Niu, Gang; Ma, Ying; Kiesewetter, Dale O.; Chen, Xiaoyuan

    2012-01-01

    Vascular endothelial growth factor (VEGF) is one of the most important mediators of angiogenesis. Single-chain (sc)-VEGF protein containing an N-terminal Cys-tag has been designed for site-specific modification with a variety of imaging and therapeutic moieties. Site-specific labeling of scVEGF with thiol-reactive prosthetic group, N-[2-(4-18F-fluorobenzamido) ethyl] maleimide ([18F]FBEM) for positron emission tomography (PET) imaging of VEFGR may provide a new tracer which has great potential for clinical translation. Methods: [18F]FBEM-scVEGF was synthesized by site-specific conjugation of 18F-FBEM to a thiol group in Cys-tag of scVEGF at room temperature. The functional activity after labeling was tested by immunofluorescence staining, cellular uptake and efflux. The tumor targeting and in vivo properties were evaluated by biodistribution and microPET studies in tumor-bearing mice. Results: The radiolabeling yield and specific activity of [18F]FBEM-scVEGF were 20.6 ± 15.1% (based on starting [18F]FBEM, uncorrected, n = 5) and 58.8 ± 12.4 GBq/µmol, respectively. Noninvasive microPET and direct tissue sampling experiments demonstrated that [18F]FBEM-scVEGF had VEGFR specific tumor uptake in MDA-MB-435, U87MG and 4T1 xenograft models. The optimal tumor uptake was achieved at 2 h p.i., which can be partially, but significantly blocked by co-injection of non-labeled scVEGF protein. Overall, [18F]FBEM-scVEGF showed VEGFR specific tumor uptake. Conclusion: The scVEGF was site-specifically labeled with 18F via [18F]FBEM prosthetic group and the tracer [18F]FBEM-scVEGF exhibited high receptor binding affinity and tumor targeting efficacy. Further study of [18F] FBEM-scVEGF to evaluate angiogenesis in cancer and other disease types is warranted. PMID:22768028

  11. Development of a prototype Open-close positron emission tomography system

    SciTech Connect

    Yamamoto, Seiichi Okumura, Satoshi; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Hatazawa, Jun

    2015-08-15

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

  12. Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

    SciTech Connect

    Bradshaw, Tyler J.; Yip, Stephen; Jallow, Ngoneh; Forrest, Lisa J.; Jeraj, Robert

    2014-06-01

    Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeated after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies

  13. [11C]-(R)-PK11195 positron emission tomography in patients with complex regional pain syndrome

    PubMed Central

    Jeon, So Yeon; Seo, Seongho; Lee, Jae Sung; Choi, Soo-Hee; Lee, Do-Hyeong; Jung, Ye-Ha; Song, Man-Kyu; Lee, Kyung-Jun; Kim, Yong Chul; Kwon, Hyun Woo; Im, Hyung-Jun; Lee, Dong Soo; Cheon, Gi Jeong; Kang, Do-Hyung

    2017-01-01

    Abstract Complex regional pain syndrome (CRPS) is characterized by severe and chronic pain, but the pathophysiology of this disease are not clearly understood. The primary aim of our case–control study was to explore neuroinflammation in patients with CRPS using positron emission tomography (PET), with an 18-kDa translocator protein specific radioligand [11C]-(R)-PK11195. [11C]-(R)-PK11195 PET scans were acquired for 11 patients with CRPS (30–55 years) and 12 control subjects (30–52 years). Parametric image of distribution volume ratio (DVR) for each participant was generated by applying a relative equilibrium-based graphical analysis. The DVR of [11C]-(R)-PK11195 in the caudate nucleus (t(21) = −3.209, P = 0.004), putamen (t(21) = −2.492, P = 0.022), nucleus accumbens (t(21) = −2.218, P = 0.040), and thalamus (t(21) = −2.395, P = 0.026) were significantly higher in CRPS patients than in healthy controls. Those of globus pallidus (t(21) = −2.045, P = 0.054) tended to be higher in CRPS patients than in healthy controls. In patients with CRPS, there was a positive correlation between the DVR of [11C]-(R)-PK11195 in the caudate nucleus and the pain score, the visual analog scale (r = 0.661, P = 0.026, R2 = 0.408) and affective subscales of McGill Pain Questionnaire (r = 0.604, P = 0.049, R2 = 0.364). We demonstrated that neuroinflammation of CRPS patients in basal ganglia. Our results suggest that microglial pathology can be an important pathophysiology of CRPS. Association between the level of caudate nucleus and pain severity indicated that neuroinflammation in this region might play a key role. These results may be essential for developing effective medical treatments. PMID:28072713

  14. Transfer of learning with an application to the physics of positron emission tomography

    NASA Astrophysics Data System (ADS)

    Aryal, Bijaya

    2007-12-01

    A series of teaching activities using physical models was developed to present some portions of physics of Positron Emission Tomography (PET) and investigate students' understanding and transfer of learning in physics to a medical technology. A teaching interview protocol consistent with a qualitative research methodology was developed and administered to the students enrolled in an algebra-based introductory level physics course. 16 students participated in individual interviews and another 21 students participated in the group sessions. The major objectives of the teaching interviews were to investigate students' transfer of physics learning from their prior experiences to the provided physical models, from one model to the other and from the models to the PET problems. The study adapted phenomenological research methodology in analyzing students' use of cognitive resources and cognitive strategies during knowledge construction and reconstruction. A resource based transfer model framed under the cognitive theory of learning and consistent with contemporary views of transfer was used to describe the transfer of physics learning. Results of the study indicated both appropriate and inappropriate use of the students' prior conceptual resources in novel contexts. Scaffolding and questioning were found to be effective in activating appropriate and suppressing the inappropriate resources. The physical models used as analogies were found useful in transferring physics learning to understand image construction in PET. Positive transfer was possible when the models were introduced in an appropriate sequence. The results of the study indicate the occurrence of three types of non-scaffolded transfer---spontaneous, semi spontaneous and non-spontaneous. The research found connections between sequencing of hints and phrasing of information in activating students' different conceptual resources. A qualitative investigation based on Vygotsky's Zone of Proximal Development (ZPD

  15. Molecular Imaging Probes for Positron Emission Tomography and Optical Imaging of Sentinel Lymph Node and Tumor

    NASA Astrophysics Data System (ADS)

    Qin, Zhengtao

    Molecular imaging is visualizations and measurements of in vivo biological processes at the molecular or cellular level using specific imaging probes. As an emerging technology, biocompatible macromolecular or nanoparticle based targeted imaging probes have gained increasing popularities. Those complexes consist of a carrier, an imaging reporter, and a targeting ligand. The active targeting ability dramatically increases the specificity. And the multivalency effect may further reduce the dose while providing a decent signal. In this thesis, sentinel lymph node (SLN) mapping and cancer imaging are two research topics. The focus is to develop molecular imaging probes with high specificity and sensitivity, for Positron Emission Tomography (PET) and optical imaging. The objective of this thesis is to explore dextran radiopharmaceuticals and porous silicon nanoparticles based molecular imaging agents. Dextran polymers are excellent carriers to deliver imaging reporters or therapeutic agents due to its well established safety profile and oligosaccharide conjugation chemistry. There is also a wide selection of dextran polymers with different lengths. On the other hand, Silicon nanoparticles represent another class of biodegradable materials for imaging and drug delivery. The success in fluorescence lifetime imaging and enhancements of the immune activation potency was briefly discussed. Chapter 1 begins with an overview on current molecular imaging techniques and imaging probes. Chapter 2 presents a near-IR dye conjugated probe, IRDye 800CW-tilmanocept. Fluorophore density was optimized to generate the maximum brightness. It was labeled with 68Ga and 99mTc and in vivo SLN mapping was successfully performed in different animals, such as mice, rabbits, dogs and pigs. With 99mTc labeled IRDye 800CW-tilmanocept, chapter 3 introduces a two-day imaging protocol with a hand-held imager. Chapter 4 proposed a method to dual radiolabel the IRDye 800CW-tilmanocept with both 68Ga and

  16. Image reconstruction for a Positron Emission Tomograph optimized for breast cancer imaging

    SciTech Connect

    Virador, Patrick R.G.

    2000-04-01

    The author performs image reconstruction for a novel Positron Emission Tomography camera that is optimized for breast cancer imaging. This work addresses for the first time, the problem of fully-3D, tomographic reconstruction using a septa-less, stationary, (i.e. no rotation or linear motion), and rectangular camera whose Field of View (FOV) encompasses the entire volume enclosed by detector modules capable of measuring Depth of Interaction (DOI) information. The camera is rectangular in shape in order to accommodate breasts of varying sizes while allowing for soft compression of the breast during the scan. This non-standard geometry of the camera exacerbates two problems: (a) radial elongation due to crystal penetration and (b) reconstructing images from irregularly sampled data. Packing considerations also give rise to regions in projection space that are not sampled which lead to missing information. The author presents new Fourier Methods based image reconstruction algorithms that incorporate DOI information and accommodate the irregular sampling of the camera in a consistent manner by defining lines of responses (LORs) between the measured interaction points instead of rebinning the events into predefined crystal face LORs which is the only other method to handle DOI information proposed thus far. The new procedures maximize the use of the increased sampling provided by the DOI while minimizing interpolation in the data. The new algorithms use fixed-width evenly spaced radial bins in order to take advantage of the speed of the Fast Fourier Transform (FFT), which necessitates the use of irregular angular sampling in order to minimize the number of unnormalizable Zero-Efficiency Bins (ZEBs). In order to address the persisting ZEBs and the issue of missing information originating from packing considerations, the algorithms (a) perform nearest neighbor smoothing in 2D in the radial bins (b) employ a semi-iterative procedure in order to estimate the unsampled data

  17. Budget impact from the incorporation of positron emission tomography – computed tomography for staging lung cancers

    PubMed Central

    Biz, Aline Navega; Caetano, Rosângela

    2015-01-01

    OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer. METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used. RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively. CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated. PMID:26274871

  18. Design and development of a dedicated mammary and axillary region positron emission tomography system

    NASA Astrophysics Data System (ADS)

    Doshi, Niraj Kumar

    Breast cancer is the second leading cause of cancer death in women. Currently, mammography and physical breast examination, both non-invasive techniques, provide the two most effective methods available for screening potential breast cancer patients. During the management of patients, however, several invasive techniques such as axillary lymph node dissection, core biopsies and lumpectomies, are utilized to determine the stage or malignancy of the disease with significant cost and morbidity associated with them. Positron Emission Tomography (PET), using [F-18] fluorodeoxyglucose (FDG) tracer is a sensitive and non-invasive imaging modality that may be a cost-effective alternative to certain invasive procedures. In this project we have developed a low cost, high performance, dedicated PET camera (maxPET) for mammary and axillary region imaging. The system consists of two 15x15 cm2 planar scintillation detector arrays composed of modular detectors operating in coincidence. The modular detectors are comprised of a 9x9 array of 3x3x20 mm3 lutetiurn oxyorthosilicate (LSO) detector elements, read out by a 5x5 array of position- sensitive photomultiplier tubes. The average measured intrinsic spatial resolution of a detector module is 2.26 mm with a sensitivity of up to 40% for a central point source. The measured coincidence timing resolution for two modules is 2.4 ns. The average energy resolution measured across the entire two detector plates is 21.6%. The coincidence timing resolution for the entire system is 8.1 ns. A line bar phantom was imaged and images were reconstructed using the focal plane tomography algorithm. A 4 mm projection image resolution was measured based on profiles taken through the line bar phantom images. The goal of the maxPET system will be to aid in breast cancer patient management by assisting in imaging women with dense, fibro-glandular breasts, detecting axillary lymph node metastases without surgery, monitoring chemotherapy effectiveness and

  19. Development of Traceable Phantoms for Improved Image Quantification in Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zimmerman, Brian

    2014-03-01

    Clinical trials for new drugs increasingly rely on imaging data to monitor patient response to the therapy being studied. In the case of radiopharmaceutical applications, imaging data are also used to estimate organ and tumor doses in order to arrive at the optimal dosage for safe and effective treatment. Positron Emission Tomography (PET) is one of the most commonly used imaging modalities for these types of applications. In large, multicenter trials it is crucial to minimize as much as possible the variability that arises due to use of different types of scanners and other instrumentation so that the biological response can be more readily evaluated. This can be achieved by ensuring that all the instruments are calibrated to a common standard and that their performance is continuously monitored throughout the trial. Maintaining links to a single standard also enables the comparability of data acquired on a heterogeneous collection of instruments in different clinical settings. As the standards laboratory for the United States, the National Institute of Standards and Technology (NIST) has been developing a suite of phantoms having traceable activity content to enable scanner calibration and performance testing. The configurations range from small solid cylindrical sources having volumes from 1 mL to 23 mL to large cylinders having a total volume of 9 L. The phantoms are constructed with 68Ge as a long-lived substitute for the more clinically useful radionuclide 18F. The contained activity values are traceable to the national standard for 68Ge and are also linked to the standard for 18F through a careful series of comparisons. The techniques that have been developed are being applied to a variety of new phantom configurations using different radionuclides. Image-based additive manufacturing techniques are also being investigated to create fillable phantoms having irregular shapes which can better mimic actual organs and tumors while still maintaining traceability

  20. Development of a prototype Open-close positron emission tomography system

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Okumura, Satoshi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Hatazawa, Jun

    2015-08-01

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

  1. Positron emission tomography assessment of effects of benzodiazepines on regional glucose metabolic rate in patients with anxiety disorder

    SciTech Connect

    Buchsbaum, M.S.; Wu, J.; Haier, R.; Hazlett, E.; Ball, R.; Katz, M.; Sokolski, K.; Lagunas-Solar, M.; Langer, D.

    1987-06-22

    Patients with generalized anxiety disorder (n = 18) entered a 21-day, double-blind, placebo-controlled random assignment trial of clorazepate. Positron emission tomography with YF-deoxyglucose was carried out before and after treatment. Decreases in glucose metabolic rate in visual cortex and relative increases in the basal ganglia and thalamus were found. A correlation between regional changes in metabolic rate and regional benzodiazepine receptor binding density from other human autopsy studies was observed; brain regions highest in receptor density showed the greatest decrease in rate.

  2. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Other Thyroid Cancers: Medullary, Anaplastic, Lymphoma and So Forth

    PubMed Central

    Araz, Mine; Çayır, Derya

    2017-01-01

    Positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (FDG) is used in staging, restaging, and evaluation of therapy response in many cancers as well as differentiated thyroid carcinomas especially in non-iodine avid variants. Its potential in less frequent thyroid tumors like medullary, anaplastic thyroid cancers, thyroid lymphoma and metastatic tumors of the thyroid however, is not well established yet. The aim of this review is to provide an overview on the recent applications and indications of 18F-FDG PET/CT in these tumors and to focus on the controversies in the clinical setting. PMID:28291004

  3. The effect of nifedipine on myocardial perfusion and metabolism in systemic sclerosis. A positron emission tomographic study

    SciTech Connect

    Duboc, D.; Kahan, A.; Maziere, B.; Loc'h, C.; Crouzel, C.; Menkes, C.J.; Amor, B.; Strauch, G.; Guerin, F.; Syrota, A. )

    1991-02-01

    We assessed the effect of nifedipine on myocardial perfusion and metabolism in 9 patients with systemic sclerosis, using positron emission tomography with a perfusion tracer (potassium-38) and a metabolic tracer (18F-fluorodeoxyglucose (18FDG)). Nifedipine, 20 mg 3 times daily for 1 week, induced a significant increase in 38K myocardial uptake, a significant decrease in 18FDG myocardial uptake, and a significant increase in the myocardial 38K: 18FDG ratio. These results indicate that the increase in myocardial perfusion is associated with modifications in myocardial energy metabolism, which probably result from a beneficial anti-ischemic effect of nifedipine in patients with systemic sclerosis.

  4. Metastatic superscan in prostate carcinoma on gallium-68-prostate-specific membrane antigen positron emission tomography/computed tomography scan.

    PubMed

    Agarwal, Krishan Kant; Tripathi, Madhavi; Kumar, Rajeev; Bal, Chandrasekhar

    2016-01-01

    We describe the imaging features of a metastatic superscan on gallium-68 Glu-NH-CO-NH-Lys-(Ahx)-[Ga-68(HBED-CC)], abbreviated as gallium-68-prostate-specific membrane antigen ((68)Ga-PSMA) positron emission tomography/computed tomography (PET/CT) imaging. (68)Ga-PSMA is novel radiotracer undergoing evaluation for PET/CT imaging of prostate carcinoma. This patient had a superscan of metastases on conventional bone scintigraphy and was referred for (68)Ga-PSMA PET/CT to evaluate the feasibility of (177)Lu-PSMA therapy.

  5. 18F-fluorodeoxyglucose positron emission tomography as a noninvasive method for the diagnosis of primary pulmonary artery sarcoma.

    PubMed

    Dias, Olívia Meira; Lombardi, Elisa Maria Siqueira; Canzian, Mauro; Soares Júnior, José; Vieira, Lucas de Oliveira; Terra Filho, Mário

    2011-01-01

    Pulmonary artery sarcomas are rare, difficult-to-diagnose tumors that frequently mimic chronic pulmonary thromboembolism. We report the cases of two female patients with clinical signs of dyspnea and lung masses associated with pulmonary artery filling defects on chest CT angiography. We performed 18F-fluorodeoxyglucose positron emission tomography, which revealed increased radiotracer uptake in those lesions. Pulmonary artery sarcoma was subsequently confirmed by anatomopathological examination. We emphasize the importance of this type of tomography as a noninvasive method for the diagnosis of these tumors.

  6. Pulmonary artery intimal sarcoma: the role of ¹⁸F-fluorodeoxyglucose positron emission tomography in monitoring response to treatment.

    PubMed

    Ote, Enrique Leonardo P; Oriuchi, Noboru; Miyashita, Go; Paudyal, Bishnuhari; Ishikita, Tomohiro; Arisaka, Yukiko; Higuchi, Tetsuya; Hirato, Junko; Endo, Keigo

    2011-05-01

    We report the case of 58-year-old man with pulmonary artery intimal sarcoma. He initially presented with cough, right-sided chest pain, and shortness of breath. Although the diagnosis of pulmonary embolism had been considered, chest radiograph and pulmonary perfusion scintigraphy showed a mass in the right hilum and no perfusion in the right lung. (18)F-fluorodeoxyglucose positron emission computed tomography (FDGPET) showed increased FDG uptake in the mass obstructing the right pulmonary artery. Fine-needle biopsy revealed a pathological diagnosis of pulmonary artery intimal sarcoma. The patient was successfully treated with radiotherapy and adjuvant chemotherapy. FDG-PET was used for monitoring the response to therapy.

  7. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in a rare case of carcinoma stomach with concomitant silicosis

    PubMed Central

    Sasikumar, Arun; Joy, Ajith; Unni, Madhavan; Madhavan, Jayaprakash

    2016-01-01

    The role of fluorine-18 fluorodeoxyglucose. (18F-FDG) positron emission tomography. (PET)/computed tomography. (CT) in the initial staging of various malignancies is now well established. However, nonspecificity of FDG occasionally results in tracer uptake in benign lung lesions. The authors describe a complicated case of carcinoma stomach with multiple nodules and a cavitary lesion in lungs where 18F-FDG PET CT done for initial staging revealed FDG avid mass in stomach, FDG avid multiple mediastinal lymph nodes and multiple intensely FDG avid bilateral lung lesions. The FDG avid lung lesions turned out to be due to silicosis as confirmed by histopathology. PMID:27833322

  8. Comparison of diffuse optical tomography of human breast with whole-body and breast-only positron emission tomography

    PubMed Central

    Konecky, Soren D.; Choe, Regine; Corlu, Alper; Lee, Kijoon; Wiener, Rony; Srinivas, Shyam M.; Saffer, Janet R.; Freifelder, Richard; Karp, Joel S.; Hajjioui, Nassim; Azar, Fred; Yodh, Arjun G.

    2008-01-01

    We acquire and compare three-dimensional tomographic breast images of three females with suspicious masses using diffuse optical tomography (DOT) and positron emission tomography (PET). Co-registration of DOT and PET images was facilitated by a mutual information maximization algorithm. We also compared DOT and whole-body PET images of 14 patients with breast abnormalities. Positive correlations were found between total hemoglobin concentration and tissue scattering measured by DOT, and fluorodeoxyglucose (18F-FDG) uptake. In light of these observations, we suggest potential benefits of combining both PET and DOT for characterization of breast lesions. PMID:18383664

  9. Comparison of diffuse optical tomography of human breast with whole-body and breast-only positron emission tomography.

    PubMed

    Konecky, Soren D; Choe, Regine; Corlu, Alper; Lee, Kijoon; Wiener, Rony; Srinivas, Shyam M; Saffer, Janet R; Freifelder, Richard; Karp, Joel S; Hajjioui, Nassim; Azar, Fred; Yodh, Arjun G

    2008-02-01

    We acquire and compare three-dimensional tomographic breast images of three females with suspicious masses using diffuse optical tomography (DOT) and positron emission tomography (PET). Co-registration of DOT and PET images was facilitated by a mutual information maximization algorithm. We also compared DOT and whole-body PET images of 14 patients with breast abnormalities. Positive correlations were found between total hemoglobin concentration and tissue scattering measured by DOT, and fluorodeoxyglucose (18F-FDG) uptake. In light of these observations, we suggest potential benefits of combining both PET and DOT for characterization of breast lesions.

  10. Reduced cerebral glucose metabolism and increased brain capillary permeability following high-dose methotrexate chemotherapy: a positron emission tomographic study

    SciTech Connect

    Phillips, P.C.; Dhawan, V.; Strother, S.C.; Sidtis, J.J.; Evans, A.C.; Allen, J.C.; Rottenberg, D.A.

    1987-01-01

    Regional glucose metabolic rate constants and blood-to-brain transport of rubidium were estimated using positron emission tomography in an adolescent patient with a brain tumor, before and after chemotherapy with intravenous high-dose methotrexate. Widespread depression of cerebral glucose metabolism was apparent 24 hours after drug administration, which may reflect reduced glucose phosphorylation, and the influx rate constant for /sup 82/Rb was increased, indicating a drug-induced alteration in blood-brain barrier function. Associated changes in neuropsychological performance, electroencephalogram, and plasma amino acid concentration were identified in the absence of evidence of systemic methotrexate toxicity, suggesting primary methotrexate neurotoxicity.

  11. Novel amphiphilic probes for [18F]-radiolabeling preformed liposomes and determination of liposomal trafficking by positron emission tomography.

    PubMed

    Urakami, Takeo; Akai, Shuji; Katayama, Yurie; Harada, Norihiro; Tsukada, Hideo; Oku, Naoto

    2007-12-27

    Positron-emission tomography (PET) is a noninvasive real-time functional imaging system and is expected to be useful for the development of new drug candidates in clinical trials. For its application with preformulated liposomes, we devised an optimized [18F]-compound and developed a direct liposome modification method that we termed the "solid-phase transition method". We were successful in using 1-[18F]fluoro-3,6-dioxatetracosane ([18F]7a) for in vivo trafficking of liposomes. This method might be a useful tool in preclinical and clinical studies of lipidic particle-related drugs.

  12. Role of F18 fluorodeoxyglucose positron-emission tomography/computed tomography in the management of Askin's tumor.

    PubMed

    Santhosh, Sampath; Kashyap, Raghava; Bhattacharya, Anish; Kumar Jindal, Surinder; Rai Mittal, Bhagwant

    2013-07-01

    A primitive neuroectodermal tumor (PNET) of the thoraco-abdominal region is one of a group of small round cell tumors usually found in children and young adults, originally described by Askin et al. Most cases arise in the soft-tissues of the thorax, but may rarely occur within the lung with the symptoms of chest wall pain, pleural effusion and dyspnea. The authors present two cases demonstrating the utility of F18 fluorodeoxyglucose positron-emission tomography/computed tomography in the staging and prognosis of PNET of the chest wall.

  13. New techniques for positron emission tomography in the study of human neurological disorders

    SciTech Connect

    Kuhl, D.E.

    1993-01-01

    This progress report describes accomplishments of four programs. The four programs are entitled (1) Faster,simpler processing of positron-computing precursors: New physicochemical approaches, (2) Novel solid phase reagents and methods to improve radiosynthesis and isotope production, (3) Quantitative evaluation of the extraction of information from PET images, and (4) Optimization of tracer kinetic methods for radioligand studies in PET.

  14. SU-E-T-230: Measurement of Proton-Activated Positron Emission with PRESAGE 3-D Dosimeters

    SciTech Connect

    Carroll, M; Mawlawi, O; Ibbott, G; Adamovics, J

    2014-06-01

    Purpose: Measurement of positron emission following proton beam irradiation of a target has been studied as a method of in-vivo dosimetry. Relative dosimetry studies between a phantom and treatment plan are susceptible to range uncertainties from material heterogeneities and setup error. By using the radiochromic polyurethane dosimeter PRESAGE, we can correlate the proton dose distribution to the PET activity measurement within a single detector. The PRESAGE formulation used was developed for high-LET proton radiotherapy, has similar density and RLSP to tissue, and consists of a greater carbon component, which gives it a higher positron signal than many other 3D detectors. Methods: Three cylindrical PRESAGE dosimeters were irradiated semi-uniformly to 500 cGy with 180- MeV protons. The beam was directed along the dosimeter axis and delivered a 2-cm SOBP at the center of the dosimeter. The dosimeters were rushed to a nearby PET/CT where imaging began within 15 minutes, less than a single half-life of 11C. A 3-hr measurement captured the full activation decay. Afterwards, the dose profiles were measured by optical-CT. A direct comparison between the measured dose and the positron emission was performed using CERR software. Results: The correlations between dose distributions and PET activity were consistent with previous studies in that the proximal region of the SOBP displayed the highest activity. The spatial distributions between the dose and activity were similar. Along the central axis of the beam, we found a shift in the distal 80% of 1 cm. The lateral profile showed good agreement between dose and activity. PET imaging times between 30-min and 3-hrs showed <5% discrepancy. Conclusion: PRESAGE dosimeters offer a strong and unique potential to accurately correlate dosimetric and PET activation information. Implementation in an anthropomorphic phantom could be used to study representative treatment plans. NIH grant 5R01CA100835.

  15. Identification of ischemic and hibernating myocardium: feasibility of post-exercise F-18 deoxyglucose positron emission tomography

    SciTech Connect

    Marwick, T.H.; MacIntyre, W.J.; Salcedo, E.E.; Go, R.T.; Saha, G.; Beachler, A. )

    1991-02-01

    The identification of ischemic and hibernating myocardium facilitates the selection of patients most likely to benefit from revascularization. This study examined the feasibility of metabolic imaging, using post-exercise F-18 deoxyglucose positron emission tomography (FDG-PET) for the diagnosis of both ischemia and hibernation in 27 patients with known coronary anatomy. Normal post-exercise FDG uptake was defined in each patient by reference to normal resting perfusion and normal coronary supply. Abnormal elevation of FDG (ischemia or hibernation) was compared in 13 myocardial segments in each patient, with the results of dipyridamole stress perfusion imaging performed by rubidium-82 positron emission tomography (Rb-PET). Myocardial ischemia was diagnosed by either FDG-PET or Rb-PET in 34 segments subtended by significant local coronary stenoses. Increased FDG uptake was present in 32/34 (94%) and a reversible perfusion defect was identified by Rb-PET in 22/34 (65%, p less than .01). In 3 patients, ischemia was identified by metabolic imaging alone. In 16 patients with previous myocardial infarction, perfusion defects were present at rest in 89 regions, 30 of which (34%) demonstrated increased FDG uptake, consistent with the presence of hibernation. Increased post-exercise FDG uptake appears to be a sensitive indicator of ischemia and myocardial hibernation. Increased post-exercise FDG uptake, appears to be a sensitive indicator of ischemia and myocardial hibernation. This test may be useful in selecting post-infarction patients for revascularization.

  16. Regional cerebral metabolic alterations in dementia of the Alzheimer type: positron emission tomography with (/sup 18/F)fluorodeoxyglucose

    SciTech Connect

    Friedland, R.P.; Budinger, T.F.; Ganz, E.; Yano, Y.; Mathis, C.A.; Koss, B.; Ober, B.A.; Huesman, R.H.; Derenzo, S.E.

    1983-08-01

    Alzheimer disease is the most common cause of dementia in adults. Despite recent advances in our understanding of its anatomy and chemistry, we remain largely ignorant of its pathogenesis, physiology, diagnosis, and treatment. Dynamic positron emission tomography using (/sup 18/F)fluorodeoxyglucose (FDG) was performed on the Donner 280-crystal ring in 10 subjects with dementia of the Alzheimer type and six healthy age-matched controls. Ratios comparing mean counts per resolution element in frontal, temporoparietal, and entire cortex regions in brain sections 10 mm thick obtained 40-70 min following FDG injection showed relatively less FDG uptake in the temporoparietal cortex bilaterally in all the Alzheimer subjects (p less than 0.01). Left-right alterations were less prominent than the anteroposterior changes. This diminished uptake was due to lowered rates of FDG use and suggests that the metabolic effects of Alzheimer disease are most concentrated in the temporoparietal cortex. Positron emission tomography is a most powerful tool for the noninvasive in vivo assessment of cerebral pathophysiology in dementia.

  17. Investigation of brain tumors using 18F-fluorobutyl ethacrynic amide and its metabolite with positron emission tomography

    PubMed Central

    Huang, Ying-Cheng; Huang, Ho-Lien; Yeh, Chun-Nan; Lin, Kun-Ju; Yu, Chung-Shan

    2015-01-01

    To date, imaging of malignant glioma remains challenging. In positron emission tomography-related diagnostic imaging, differential tumor uptake of 3′-deoxy-3′-[18F] fluorothymidine ([18F]FLT) has been shown to reflect the levels of cell proliferation and DNA synthesis. However, additional biomarkers for tumors are urgently required. Aberrant levels of glutathione transferase (GST) activity have been hypothesized to constitute such a novel diagnostic marker. Here, a C6 rat glioma tumor model was used to assess the ability of the positron emission tomography tracers, [18F]FLT and 18F-fluorobutyl ethacrynic amide ([18F]FBuEA), to indicate reactive oxygen species-induced stress responses as well as detoxification-related processes in tumors. Using a GST activity assay, we were able to demonstrate that FBuEA is more readily catalyzed by GST-π than by GST-α. Furthermore, we showed that FBuEA-GS, a metabolite of FBuEA, elicits greater cytotoxicity in tumor cells than in normal fibroblast cells. Finally, in vitro and in vivo investigation of radiotracer distribution of [18F]FBuEA and [18F] FBuEA-GS revealed preferential accumulation in C6 glioma tumor cells over normal fibroblast cells for [18F]FBuEA-GS but not for [18F]FBuEA. PMID:26244025

  18. 18F-AV-1451 positron emission tomography in Alzheimer’s disease and progressive supranuclear palsy

    PubMed Central

    Vázquez Rodríguez, Patricia; Hong, Young T.; Allinson, Kieren S. J.; Williamson, David; Borchert, Robin J.; Sami, Saber; Cope, Thomas E.; Bevan-Jones, W. Richard; Jones, P. Simon; Arnold, Robert; Surendranathan, Ajenthan; Mak, Elijah; Su, Li; Fryer, Tim D.; Aigbirhio, Franklin I.; O’Brien, John T.; Rowe, James B.

    2017-01-01

    Abstract The ability to assess the distribution and extent of tau pathology in Alzheimer’s disease and progressive supranuclear palsy in vivo would help to develop biomarkers for these tauopathies and clinical trials of disease-modifying therapies. New radioligands for positron emission tomography have generated considerable interest, and controversy, in their potential as tau biomarkers. We assessed the radiotracer 18F-AV-1451 with positron emission tomography imaging to compare the distribution and intensity of tau pathology in 15 patients with Alzheimer’s pathology (including amyloid-positive mild cognitive impairment), 19 patients with progressive supranuclear palsy, and 13 age- and sex-matched controls. Regional analysis of variance and a support vector machine were used to compare and discriminate the clinical groups, respectively. We also examined the 18F-AV-1451 autoradiographic binding in post-mortem tissue from patients with Alzheimer’s disease, progressive supranuclear palsy, and a control case to assess the 18F-AV-1451 binding specificity to Alzheimer’s and non-Alzheimer’s tau pathology. There was increased 18F-AV-1451 binding in multiple regions in living patients with Alzheimer’s disease and progressive supranuclear palsy relative to controls [main effect of group, F(2,41) = 17.5, P < 0.0001; region of interest × group interaction, F(2,68) = 7.5, P < 0.00001]. More specifically, 18F-AV-1451 binding was significantly increased in patients with Alzheimer’s disease, relative to patients with progressive supranuclear palsy and with control subjects, in the hippocampus and in occipital, parietal, temporal, and frontal cortices (t’s > 2.2, P’s < 0.04). Conversely, in patients with progressive supranuclear palsy, relative to patients with Alzheimer’s disease, 18F-AV-1451 binding was elevated in the midbrain (t = 2.1, P < 0.04); while patients with progressive supranuclear palsy showed, relative to controls, increased 18F-AV-1451 uptake

  19. Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission Tomography

    SciTech Connect

    Campbell, Janice M. Wong, C. Oliver; Muzik, Otto; Marples, Brian; Joiner, Michael; Burmeister, Jay

    2009-05-01

    Purpose: To evaluate a patient-specific single photon emission computed tomography (SPECT)-based method of dose calculation for treatment planning of yttrium-90 ({sup 90}Y) microsphere selective internal radiotherapy (SIRT). Methods and Materials: Fourteen consecutive {sup 90}Y SIRTs for colorectal liver metastasis were retrospectively analyzed. Absorbed dose to tumor and normal liver tissue was calculated by partition methods with two different tumor/normal liver vascularity ratios: an average 3:1 and a patient-specific ratio derived from pretreatment technetium-99m macroaggregated albumin SPECT. Tumor response was quantitatively evaluated from fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography scans. Results: Positron emission tomography showed a significant decrease in total tumor standardized uptake value (average, 52%). There was a significant difference in the tumor absorbed dose between the average and specific methods (p = 0.009). Response vs. dose curves fit by linear and linear-quadratic modeling showed similar results. Linear fit r values increased for all tumor response parameters with the specific method (+0.20 for mean standardized uptake value). Conclusion: Tumor dose calculated with the patient-specific method was more predictive of response in liver-directed {sup 90}Y SIRT.

  20. The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

    SciTech Connect

    Yang, Jaewon; Yamamoto, Tokihiro; Mazin, Samuel R.; Graves, Edward E.; Keall, Paul J.

    2014-02-15

    Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D

  1. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma

    PubMed Central

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.

    2016-01-01

    Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0

  2. Myocardial Blood Flow Quantification for Evaluation of Coronary Artery Disease by Positron Emission Tomography, Cardiac Magnetic Resonance Imaging, and Computed Tomography

    PubMed Central

    Waller, Alfonso H.; Blankstein, Ron; Kwong, Raymond Y.; Di Carli, Marcelo F.

    2014-01-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging and computed tomography, and its emerging clinical applications. PMID:24718671

  3. (/sup 11/C)clorgyline and (/sup 11/C)-L-deprenyl and their use in measuring functional monoamine oxidase activity in the brain using positron emission tomography

    DOEpatents

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.

    1986-04-17

    This invention involves a new strategy for imaging the activity of the enzyme monoamine oxidase in the living body by using /sup 11/C-labeled enzyme inhibitors which bind irreversibly to an enzyme as a result of catalysis. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography. 2 figs.

  4. [In vivo imaging of liposomal small interfering RNA (siRNA) trafficking by positron emission tomography].

    PubMed

    Ando, Hidenori; Yonenaga, Norihito; Asai, Tomohiro; Hatanaka, Kentaro; Koide, Hiroyuki; Tsuzuku, Takuma; Harada, Norihiro; Tsukada, Hideo; Oku, Naoto

    2012-01-01

    In the development of nucleic acid medicines such as small interfering RNA (siRNA) drugs, one problem is how to study the pharmacokinetics and pharmacodynamics, since the precise in vivo behavior of siRNA is hard to detect. In this research, to establish a highly sensitive detection system of siRNA biodistribution in the whole body, the technology of positron imaging was applied. First, a one-step synthetic method in which double-stranded siRNA was directly labeled by a positron emitter, (18)F, was developed. By using [(18)F]-labeled siRNA ([(18)F]-siRNA), the complex of siRNA and polycation liposomes (PCL) containing dicetylphosphate tetraethylenepentamine (TEPA-PCL) was prepared. Then, the biodistribution of the siRNA after intravenous administration to mice was analyzed by planar positron imaging system (PPIS). As a result, whereas naked [(18)F]-siRNA was immediately excreted in mouse bladder after administration, the complex with cationic liposome (CL) was trapped in the lungs. Furthermore, [(18)F]-siRNA carried with PEGylated CL (PL) was distributed throughout the body, suggesting that it circulated in the bloodstream for an extended period of time. Additionally, PET imaging revealed more detailed biodistribution of the siRNA than in vivo imaging system (IVIS) because PET imaging is not affected by the depth variation of target tissues. On the other hand, to induce high accumulation of siRNAs against c-myc, MDM2, and VEGF in tumor tissue, a tumor-targeting probe, RGD peptide, was grafted at the top of PEG chain in PEGylated TEPA-PCL and the effect of the complex on experimental lung metastasis of B16 melanoma was examined. The complex suppressed the progression of tumor. We believe that the positron imaging data would support the development of siRNA agent for clinical use.

  5. The neurobiology of glucocerebrosidase-associated parkinsonism: a positron emission tomography study of dopamine synthesis and regional cerebral blood flow.

    PubMed

    Goker-Alpan, Ozlem; Masdeu, Joseph C; Kohn, Philip D; Ianni, Angela; Lopez, Grisel; Groden, Catherine; Chapman, Molly C; Cropp, Brett; Eisenberg, Daniel P; Maniwang, Emerson D; Davis, Joie; Wiggs, Edythe; Sidransky, Ellen; Berman, Karen F

    2012-08-01

    Mutations in GBA, the gene encoding glucocerebrosidase, the enzyme deficient in Gaucher disease, are common risk factors for Parkinson disease, as patients with Parkinson disease are over five times more likely to carry GBA mutations than healthy controls. Patients with GBA mutations generally have an earlier onset of Parkinson disease and more cognitive impairment than those without GBA mutations. We investigated whether GBA mutations alter the neurobiology of Parkinson disease, studying brain dopamine synthesis and resting regional cerebral blood flow in 107 subjects (38 women, 69 men). We measured dopamine synthesis with (18)F-fluorodopa positron emission tomography, and resting regional cerebral blood flow with H(2)(15)O positron emission tomography in the wakeful, resting state in four study groups: (i) patients with Parkinson disease and Gaucher disease (n = 7, average age = 56.6 ± 9.2 years); (ii) patients with Parkinson disease without GBA mutations (n = 11, 62.1 ± 7.1 years); (iii) patients with Gaucher disease without parkinsonism, but with a family history of Parkinson disease (n = 14, 52.6 ± 12.4 years); and (iv) healthy GBA-mutation carriers with a family history of Parkinson disease (n = 7, 50.1 ± 18 years). We compared each study group with a matched control group. Data were analysed with region of interest and voxel-based methods. Disease duration and Parkinson disease functional and staging scores were similar in the two groups with parkinsonism, as was striatal dopamine synthesis: both had greatest loss in the caudal striatum (putamen Ki loss: 44 and 42%, respectively), with less reduction in the caudate (20 and 18% loss). However, the group with both Parkinson and Gaucher diseases showed decreased resting regional cerebral blood flow in the lateral parieto-occipital association cortex and precuneus bilaterally. Furthermore, two subjects with Gaucher disease without parkinsonian manifestations showed diminished striatal dopamine. In conclusion

  6. Aspects of the application of positron emission tomography to engineering studies: Drawing overlays and correction for photon attenuation

    NASA Astrophysics Data System (ADS)

    O'Dwyer, M. A.; Hawkesworth, M. R.; Walker, J.

    1988-12-01

    Two important aspects of the application of positron emission tomography in engineering are: the creation of accurate but simplified engineering drawings to overlay the radiolabel tomograms as an aid to their interpretation, and the correction of important features in tomograms for attenuation in overlying metal to provide quantitative information. The practical difficulties met in producing overlays and correcting for attenuation are described, and strategies which are proving useful to overcome them are outlined. The essential starting point is the creation in computer memory of a full three-dimensional representation of all the subject of interest. After scaling, any plane through this model can then be extracted to overlay the appropriate plane through the radiolabel distribution, and all acceptable photon trajectories can be traced from each volume element containing positron emitter to give correction factors for attenuation in the materials traversed. It is shown that it is appropriate to use the total attenuation coefficients of materials in the correction and, finally, a gradient-contour routine is described for separating true signal from background prior to correction.

  7. The fast method of Cu-porphyrin complex synthesis for potential use in positron emission tomography imaging

    NASA Astrophysics Data System (ADS)

    Kilian, Krzysztof; Pęgier, Maria; Pyrzyńska, Krystyna

    2016-04-01

    Porphyrin based photosensitizers are useful agents for photodynamic therapy and fluorescence imaging of cancer. Additionally, porphyrins are excellent metal chelators, forming stable metalo-complexes and 64Cu isotope can serve as a positron emitter (t1/2 = 12.7 h). The other advantage of 64Cu is its decay characteristics that facilitates the use of 64Cu-porphyrin complex as a therapeutic agent. Thus, 64Cu chelation with porphyrin photosensitizer may become a simple and versatile labeling strategy for clinical positron emission tomography. The present study reports a convenient method for the synthesis of Cu complex with tetrakis(4-carboxyphenyl)porphyrin (TCPP). The experimental conditions for labeling, such as the metal-to-ligand molar ratio, pH and time of reaction were optimized to achieve a high complexation efficiency in a short period of time as possible. In order to accelerate the metallation, the use of substitution reactions of cadmium or lead porphyrin and the presence of reducing agent, such as ascorbic acid, hydroxylamine and flavonoid - morin, were evaluated. The optimum conditions for the synthesis of the copper complex were borate buffer at pH 9 with the addition of 10-fold molar excess, with respect to Cu2 + ions and TCPP and ascorbic acid which resulted in reduction of the reaction time from 30 min to below 1 min.

  8. Positron emission tomographic imaging of tumors using monoclonal antibodies. Progress report, November 1, 1992--October 31, 1993

    SciTech Connect

    Zalutsky, M.R.

    1993-07-29

    The overall goal of this project is to be able to combine the molecular specificity of monoclonal antibodies with the imaging advantages of positron emission tomography. During the past year, were have made progress in a number of areas. This report will focus on our studies evaluating the potential of two different methods for labeling a monoclonal antibody fragment with positron-emitting F-18 both in vitro and in athymic mice bearing subcutaneous D-54 MG human glioma xenografts. The F (a b{prime}){sub 2} fragment of Me1-14, a murine egg{sub 2a} reactive with an epitope of the tumor associated proteoglycan sulfate present in gliomas and melanomas, was used. This antibody is a particular interest because of our ongoing clinical radioimmunotherapy trails using Me1--14 that could ultimately benefit from the determination of quantitative dosimetry using monoclonal antibody PET imaging. Our results demonstrated, for the first time, that MAb fragments could be labeled with F-18 with retention of immunoreactivity and affinity. Further, they show that selective and specific tumor uptake of an F-18 labeled MAb fragment can be achieved in a xenograft model in a time frame compatible with the short half life of this nuclide.

  9. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using (15)O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets.

    PubMed

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich; Ladefoged, Claes N; Højgaard, Liselotte; Greisen, Gorm; Law, Ian

    2015-11-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed arterial spin labeling (ASL) magnetic resonance imaging (MR) on a hybrid PET/MR in seven newborn piglets. Positron emission tomography was performed with IV injections of 20 MBq and 100 MBq (15)O-water to confirm CBF reliability at low activity. Cerebral blood flow was quantified using a one-tissue-compartment-model using two input functions: an arterial input function (AIF) or an image-derived input function (IDIF). The mean global CBF (95% CI) PET-AIF, PET-IDIF, and ASL at baseline were 27 (23; 32), 34 (31; 37), and 27 (22; 32) mL/100 g per minute, respectively. At acetazolamide stimulus, PET-AIF, PET-IDIF, and ASL were 64 (55; 74), 76 (70; 83) and 79 (67; 92) mL/100 g per minute, respectively. At baseline, differences between PET-AIF, PET-IDIF, and ASL were 22% (P<0.0001) and -0.7% (P=0.9). At acetazolamide, differences between PET-AIF, PET-IDIF, and ASL were 19% (P=0.001) and 24% (P=0.0003). In conclusion, PET-IDIF overestimated CBF. Injected activity of 20 MBq (15)O-water had acceptable concordance with 100 MBq, without compromising image quality. Single TI ASL was questionable for regional CBF measurements. Global ASL CBF and PET CBF were congruent during baseline but not during hyperperfusion.

  10. An introduction to the physics and instrumentation of positron emission tomography

    SciTech Connect

    Bennett, G.W.

    1986-06-01

    Positron-emitting radionuclides permit the use of electronic collimation and thus achieve higher resolution and better sensitivity than can be obtained with gamma-emitting radiotracers. The evolution of PET imaging systems can be traced from the use of opposed collimated scanning detectors, which had all the limitations of traditional single photon imaging devices, to the present systems which surround the subject with a large volume of detector material. The improvements in system resolution now approach the theoretical limitation imposed by positron-range, and angular deviation. The use of coding permits the use of shared electronics for reading our multiple detectors, which promises to decrease the cost of PET imaging devices, at some penalty of degraded performance. Improvements in computer architectures and capabilities permit faster reconstruction of the multiple planes imaged by multi-slice imaging systems. Software for distortion correction and image processing are still under development, and the ability to map between different devices requires the coordination of efforts between different groups in the same institution. The development and validation of the mathematical models for tracer kinetic analyses will continue to occupy the attention of clinicians and scientists involved in these developments. The desire to make these devices simple and cheap enough to be used in routine patient care is occupying the attention of industry and pioneering users, but this goal has not yet been achieved. 17 refs., 15 figs., 3 tabs.

  11. One-step synthesis of 4-[(18) F]fluorobenzyltriphenylphosphonium cation for imaging with positron emission tomography.

    PubMed

    Zhang, Zhengxing; Zhang, Chengcheng; Lau, Joseph; Colpo, Nadine; Bénard, François; Lin, Kuo-Shyan

    2016-09-01

    4-[(18) F]Fluorobenzyltriphenylphosphonium cation ((18) F-FBnTP) is a promising negative membrane potential targeting positron emission tomography tracer. However, the reported multistep radiolabeling approach for the synthesis of (18) F-FBnTP poses a challenge for routine clinical applications. In this study, we demonstrated that (18) F-FBnTP can be prepared in good conversion yields (~60%, nondecay corrected) in just one step via a copper-mediated (18) F-fluorination reaction using a pinacolyl arylboronate precursor. In addition, our data suggest that (18) F-labeled (phosphonium) cations can be efficiently prepared via a copper-mediated (18) F-fluoronation by using triflate as the counterion.

  12. An extension of the real option approach to the evaluation of health care technologies: the case of positron emission tomography.

    PubMed

    Pertile, Paolo

    2009-09-01

    This paper aims to incorporate option values into the economic evaluation of positron emission tomography (PET). The installation of this equipment requires a substantial capital outlay, while uncertainty, especially regarding the possibility of new applications, is relevant, because the evidence available is still insufficient. Treating the number of examinations to provide as a stochastic variable, the cost-effectiveness analysis is extended to include the value of flexibility both with respect to the timing of investment and to the size of the project. The threshold values of the stochastic variable that ensure the cost-effectiveness of a PET scan according to this approach are obtained as a function of the value of the incremental effectiveness.

  13. Use of 18F-2-Fluorodeoxyglucose to Label Antibody Fragments for Immuno-Positron Emission Tomography of Pancreatic Cancer

    PubMed Central

    2015-01-01

    We generated 18F-labeled antibody fragments for positron emission tomography (PET) imaging using a sortase-mediated reaction to install a trans-cyclooctene-functionalized short peptide onto proteins of interest, followed by reaction with a tetrazine-labeled-18F-2-deoxyfluoroglucose (FDG). The method is rapid, robust, and site-specific (radiochemical yields > 25%, not decay corrected). The availability of 18F-2-deoxyfluoroglucose avoids the need for more complicated chemistries used to generate carbon–fluorine bonds. We demonstrate the utility of the method by detecting heterotopic pancreatic tumors in mice by PET, using anti-Class II MHC single domain antibodies. We correlate macroscopic PET images with microscopic two-photon visualization of the tumor. Our approach provides easy access to 18F-labeled antibodies and their fragments at a level of molecular specificity that complements conventional 18F-FDG imaging. PMID:26955657

  14. Use of a YAP:Ce matrix coupled to a position-sensitive photomultiplier for high resolution positron emission tomography

    SciTech Connect

    Del Guerra, A.; Zavattini, G. |; Notaristefani, F. de |; Di Domenico, G. |; Giganti, M.; Piffanelli, A.; Pani, R.; Turra, A.

    1996-06-01

    A new scintillation detector system has been designed for application in high resolution Positron Emission Tomography (PET). The detector is a bundle of small YAlO{sub 3}:Ce (YAP) crystals closely packed (0.2 x 0.2 x 3.0 cm{sup 3}), coupled to a position sensitive photomultiplier tube (PSPMT). The preliminary results obtained for spatial resolution, time resolution, energy resolution and efficiency of two such detectors working in coincidence are presented. These are 1.2 mm for the FWHM spatial resolution, 2.0 ns for the FWHM time resolution and 20% for the FWHM energy resolution at 511 keV. The measured efficiency is (44 {+-} 3)% with a 150 keV threshold and (20 {+-} 2)% with a 300 keV threshold.

  15. Diagnostic efficacy of bone scintigraphy, magnetic resonance imaging, and positron emission tomography in bone metastases of myxoid liposarcoma.

    PubMed

    Conill, Carlos; Setoain, Xavier; Colomo, Luis; Palacín, Antonio; Combalia-Aleu, Andreu; Pomés, Jaime; Marruecos, Jordi; Vargas, Mauricio; Maurel, Joan

    2008-03-01

    Myxoid liposarcomas (MLS) have a tendency to metastasize to unusual sites. We report an unusual case of bone metastases not detected by bone scan and neither by fluorodeoxyglucose positron emission tomography (PET-FDG) and successfully identified with magnetic resonance imaging (MRI) in a patient with metachronic MLS. Histopathological examination of the primary tumor evidenced a tumor with unfavorable prognostic markers, and the biopsy of an iliac bone lesion confirmed the diagnosis of metastatic disease. On histological grounds, the tumor showed features of a more differentiated neoplasm without foci of round cells or necrosis in the latter. MRI allowed the identification of disseminated disease compared to computed tomography (CT) and PET scans. Thus, because of the heterogeneous histological features of MLS and the biological behavior of the disease, a combined approach of FDGPET-CT and MRI, may allow a more accurate staging of soft tissue sarcomas.

  16. Richter Transformation of Chronic Lymphocytic Leukemia: A Review of Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography and Molecular Diagnostics

    PubMed Central

    Janjua, Amna; Van Gestel, Frederick; Ahmad, Adeel

    2017-01-01

    Chronic lymphocytic leukemia (CLL) is a low-grade B-cell proliferative disease with a generally indolent course. In a few cases, it undergoes transformation and becomes a more aggressive malignancy, such as diffuse large B-cell lymphoma (DLBCL). This process, which is called Richter transformation (RT), is often detected too late and is associated with a poor prognosis. There are multiple molecular diagnostic approaches to detect RT in preexisting CLL. Metabolic imaging using 18-fluorine fluorodeoxyglucose positron emission tomography–computed tomography (18F-FDG PET/CT) can be a very useful tool for early detection of RT and which can hence allow for timely intervention, thereby improving the patient’s chances of survival. PMID:28191372

  17. Striatal and extrastriatal dopamine release in the common marmoset brain measured by positron emission tomography and [(18)F]fallypride.

    PubMed

    Ota, Miho; Ogawa, Shintaro; Kato, Koichi; Masuda, Chiaki; Kunugi, Hiroshi

    2015-12-01

    Previous studies have demonstrated that patients with schizophrenia show greater sensitivity to psychostimulants than healthy subjects. Sensitization to psychostimulants and resultant alteration of dopaminergic neurotransmission in rodents has been suggested as a useful model of schizophrenia. This study sought to examine the use of methylphenidate as a psychostimulant to induce dopamine release and that of [(18)F]fallypride as a radioligand to quantify the release in a primate model of schizophrenia. Four common marmosets were scanned by positron emission tomography twice, before and after methylphenidate challenge, to evaluate dopamine release. Four other marmosets were sensitized by repeated methamphetamine (MAP) administration. Then, they were scanned twice, before and after methylphenidate challenge, to evaluate whether MAP-sensitization induced greater sensitivity to methylphenidate. We revealed a main effect of the methylphenidate challenge but not the MAP pretreatment on the striatal binding potential. These results suggest that methylphenidate-induced striatal dopamine release in the common marmoset could be evaluated by [(18)F]fallypride.

  18. Bitemporal hypometabolism in Creutzfeldt-Jakob disease measured by positron emission tomography with (/sup 18/F)-2-fluorodeoxyglucose

    SciTech Connect

    Friedland, R.P.; Prusiner, S.B.; Jagust, W.J.; Budinger, T.F.; Davis, R.L.

    1984-10-01

    It is well established that Creutzfeldt-Jakob disease (CJD) is caused by a slow infectious agent similar to the scrapie prion. However, the pathogenesis of this infection is poorly understood. Positron emission tomography (PET) was performed on a 54-year-old man with autopsy confirmed CJD using (18F)-2-fluorodeoxyglucose (FDG) and the Donner 280-crystal tomograph. Temporal lobe hypometabolism with hemispheric asymmetry was observed. These findings are similar to those previously obtained in PET-FDG studies of patients with clinically defined Alzheimer disease (AD). The similarities in the regional metabolic alterations between CJD and AD provide additional evidence for the possibility that AD may be caused by a slow infectious prion.

  19. Intracranial Leptomeningeal Carcinomatosis in Three Cases from Breast Cancer Demonstrated on F-18 Fluorodeoxyglucose Positron Emission Tomography/Computerized Tomography.

    PubMed

    Ortapamuk, Hulya; Demir, Mustafa Kemal

    2017-01-01

    Leptomeningeal carcinomatosis (LC) is an uncommon late manifestation of non-central nervous system (CNS) solid tumors. With prolonged survival in solid tumors, an increased frequency of metastases is noted in these tumors too. The detection of tumor cells in the cerebrospinal fluid remains the gold standard. Noninvasively, magnetic resonance imaging is frequently used for the diagnosis of LC. Although its low sensitivity of F-18 fluorodeoxyglucose positron emission tomography/computerized tomography (F-18 FDG PET/CT) on demonstrating CNS lesions, it could be useful in identifying the possibility of LC of breast carcinoma by giving high attention to the meninges. We discuss here three cases all of them having intracranial LC; where (18)F-FDG PET/CT study helped us in the diagnosis of LC. To our knowledge, this is the second report about intracranial LC from breast cancer demonstrating on (18)F-FDG PET/CT.

  20. Imaging Spectrum and Pitfalls of 11C-Methionine Positron Emission Tomography in a Series of Patients with Intracranial Lesions

    PubMed Central

    Matsuda, Hiroshi; Kubota, Kazoo

    2016-01-01

    11C-methionine (Met) positron emission tomography (PET) is one of the most commonly used PET tracers for evaluating brain tumors. However, few reports have described tips and pitfalls of 11C-Met PET for general practitioners. Physiological 11C-Met uptake, anatomical variations, vascular disorders, non-tumorous lesions such as inflammation or dysplasia, benign brain tumors and patient condition during 11C-Met PET examination can potentially affect the image interpretation and cause false positives and negatives. These pitfalls in the interpretation of 11C-Met PET images are important for not only nuclear medicine physicians but also general radiologists. Familiarity with the spectrum and pitfalls of 11C-Met images could help prevent unfavorable clinical results caused by misdiagnoses. PMID:27134530

  1. Intracranial Leptomeningeal Carcinomatosis in Three Cases from Breast Cancer Demonstrated on F-18 Fluorodeoxyglucose Positron Emission Tomography/Computerized Tomography

    PubMed Central

    Ortapamuk, Hulya; Demir, Mustafa Kemal

    2017-01-01

    Leptomeningeal carcinomatosis (LC) is an uncommon late manifestation of non-central nervous system (CNS) solid tumors. With prolonged survival in solid tumors, an increased frequency of metastases is noted in these tumors too. The detection of tumor cells in the cerebrospinal fluid remains the gold standard. Noninvasively, magnetic resonance imaging is frequently used for the diagnosis of LC. Although its low sensitivity of F-18 fluorodeoxyglucose positron emission tomography/computerized tomography (F-18 FDG PET/CT) on demonstrating CNS lesions, it could be useful in identifying the possibility of LC of breast carcinoma by giving high attention to the meninges. We discuss here three cases all of them having intracranial LC; where 18F-FDG PET/CT study helped us in the diagnosis of LC. To our knowledge, this is the second report about intracranial LC from breast cancer demonstrating on 18F-FDG PET/CT. PMID:28242978

  2. The Role of Iodine-124-Positron Emission Tomography Imaging in the Management of Patients with Thyroid Cancer.

    PubMed

    Grewal, Ravinder K; Lubberink, Mark; Pentlow, Keith S; Larson, Steven M

    2007-07-01

    Molecular imaging is the visualization, characterization, and measurement of biologic processes at the molecular and cellular levels in human beings and other living systems. In thyroid cancer, this includes imaging iodine transport, which is active in about 80% of well-differentiated thyroid malignancies. Iodine-124 imaging with positron emission tomography (I-124-PET) is ideal for this purpose because PET provides tomographic images with spatial and contrast resolution. Because iodine-131 is the mainstay for therapy in thyroid cancer, and because success or failure of therapy depends on the degree of iodine uptake by the tumor cells, I-124-PET imaging will increasingly act as a surrogate for this treatment. This approach may serve as a model for individualized therapeutic interventions for many other malignant and nonmalignant diseases.

  3. [(18)F]Fluorodeoxyglucose Positron Emission Tomography Reveals a Complete Remission of Refractory Metastatic Melanoma after Therapy with Ipilimumab.

    PubMed

    Yordanova, Anna; Schlenkhoff, Carl; Palmedo, Holger; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-01-01

    Ipilimumab (YERVOY) is a monoclonal CTLA-4-antibody with anti-tumor-immunogenic effect and is used to treat malignant melanoma. In this case study, we present [(18)F]Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) images of a 37-year-old woman with metastatic melanoma, who was previously treated with interferon-alpha therapy and dacarbazine and still progressed. After four cycles of ipilimumab, there was a complete remission of the disease with no evidence of vital, FDG-positive tumor tissue. The follow-up for a total of 1 year confirmed the therapeutic success. This report demonstrates that FDG-PET/CT is a reliable imaging method for response monitoring in metastatic melanoma treated with ipilimumab.

  4. [18F]Fluorodeoxyglucose Positron Emission Tomography Reveals a Complete Remission of Refractory Metastatic Melanoma after Therapy with Ipilimumab

    PubMed Central

    Yordanova, Anna; Schlenkhoff, Carl; Palmedo, Holger; Essler, Markus; Ahmadzadehfar, Hojjat

    2017-01-01

    Ipilimumab (YERVOY) is a monoclonal CTLA-4-antibody with anti-tumor-immunogenic effect and is used to treat malignant melanoma. In this case study, we present [18F]Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) images of a 37-year-old woman with metastatic melanoma, who was previously treated with interferon-alpha therapy and dacarbazine and still progressed. After four cycles of ipilimumab, there was a complete remission of the disease with no evidence of vital, FDG-positive tumor tissue. The follow-up for a total of 1 year confirmed the therapeutic success. This report demonstrates that FDG-PET/CT is a reliable imaging method for response monitoring in metastatic melanoma treated with ipilimumab. PMID:28242993

  5. 18F-fluoroethyl-L-tyrosine positron emission tomography-guided diagnosis of a malignant intramedullary spinal cord tumor

    PubMed Central

    Kebir, Sied; Kimmich, Okka; Niehusmann, Pitt; Gaertner, Florian C.; Essler, Markus; Landsberg, Jennifer; Klockgether, Thomas; Simon, Matthias; Herrlinger, Ulrich; Glas, Martin

    2016-01-01

    Diagnosis in patients with a suspected malignant intramedullary lesion that requires biopsy for definitive diagnosis may be challenging, as spinal cord surgery carries the risk of irreversible neurological deficits. The current study presents the first case of 18F-fluoroethyl-L-tyrosine (18F-FET) positron emission tomography (PET) imaging in a patient with a spinal cord tumor. The patient was unsuitable for magnetic resonance imaging due to his implanted cardiac defibrillator. 18F-FET PET indicated a high-grade malignancy of the spinal cord, justifying tumor biopsy. Histological analysis was compatible with a malignant melanoma. This is also the first report demonstrating the FET-PET appearance/metabolic phenotype of a malignant melanoma of the spinal cord. PMID:28105177

  6. Development of new deoxycytidine kinase inhibitors and non-invasive in vivo evaluation using Positron Emission Tomography

    PubMed Central

    Murphy, Jennifer M.; Armijo, Amanda L.; Nomme, Julian; Lee, Chi Hang; Smith, Quentin A.; Li, Zheng; Campbell, Dean O.; Liao, Hsiang-I; Nathanson, David A.; Austin, Wayne R.; Lee, Jason T.; Darvish, Ryan; Wei, Liu; Wang, Jue; Su, Ying; Damoiseaux, Robert; Sadeghi, Saman; Phelps, Michael E.; Herschman, Harvey R.; Czernin, Johannes; Alexandrova, Anastassia N.; Jung, Michael E.; Lavie, Arnon; Radu, Caius G.

    2013-01-01

    Combined inhibition of ribonucleotide reductase and deoxycytidine kinase (dCK) in multiple cancer cell lines depletes deoxycytidine triphosphate pools leading to DNA replication stress, cell cycle arrest and apoptosis. Evidence implicating dCK in cancer cell proliferation and survival stimulated our interest in developing small molecule dCK inhibitors. Following a high throughput screen of a diverse chemical library, a structure-activity relationship study was carried out. Positron Emission Tomography (PET) using 18F-L-1-(2′-deoxy-2′-FluoroArabinofuranosyl) Cytosine (18F-L-FAC), a dCK-specific substrate, was used to rapidly rank lead compounds based on their ability to inhibit dCK activity in vivo. Evaluation of a subset of the most potent compounds in cell culture (IC50 = ∼1 – 12 nM) using the 18F-L-FAC PET pharmacodynamic assay identified compounds demonstrating superior in vivo efficacy. PMID:23947754

  7. A comparison of positron emission particle tracking (PEPT) methods for analysis of a tube-in-shell heat exchanger

    NASA Astrophysics Data System (ADS)

    Wiggins, Cody; Patel, Nitant; Ruggles, Arthur

    2016-03-01

    A positron emission particle tracking (PEPT) study of a stainless steel tube-in-shell heat exchanger is performed. Studies are performed using two different energy window settings. A new multiple particle tracking technique is introduced and used in this analysis. Results are compared to those obtained with previously established multiple particle tracking technique. Both techniques are found to be capable of flow imaging through opaque surfaces. No significant difference is observed between energy window settings using either method. Results from both methods are found to be qualitatively similar; however, it is observed that the new method exhibits consistently lower measurement uncertainty across the field of view of the scanner and is robust against the adverse effects of stationary particles in the flow field.

  8. The influence of tomograph sensitivity on kinetic parameter estimation in positron emission tomography imaging studies of the rat brain.

    PubMed

    Meikle, S R; Eberl, S; Fulton, R R; Kassiou, M; Fulham, M J

    2000-08-01

    We investigated the influence of tomograph sensitivity on reliability of parameter estimation in positron emission tomography studies of the rat brain. The kinetics of two tracers in rat striatum and cerebellum were simulated. A typical injected dose of 10 MBq and a reduced dose of 1 MBq were assumed. Kinetic parameters were estimated using a region of interest (ROI) analysis and two pixel-by-pixel analyses. Striatal binding potential was estimated as a function of effective tomograph sensitivity (S(eff)) using a simplified reference tissue model. A S(eff) value of > or =1% was required to ensure reliable parameter estimation for ROI analysis and a S(eff) of 3-6% was required for pixel-by-pixel analysis. We conclude that effective tomograph sensitivity of 3% may be an appropriate design goal for rat brain imaging.

  9. [18F] fluorodeoxyglucose-positron-emission tomography and MR imaging coregistration for presurgical evaluation of medically refractory epilepsy.

    PubMed

    Lee, K K; Salamon, N

    2009-11-01

    Epilepsy is a chronic disorder affecting approximately 1% of the population of the world. Approximately one third of patients with epilepsy remain refractory to medical therapy. For these patients, surgery is a curative option. In order for surgery to be considered, precise localization of the structural abnormality is needed. When MR imaging findings are normal, more sensitive techniques such as positron-emission tomography (PET) can help find the abnormality. Combining MR imaging and PET information increases the sensitivity of the presurgical evaluation. In this review, we discuss the clinical applications of coregistration of [(18)F] fluorodeoxyglucose (FDG)-PET with MR imaging for medically refractory epilepsy. Because FDG-PET/MR imaging coregistration has been a routine component of the presurgical evaluation for patients with epilepsy at our institution since 2004, we also included cases from our data base that exemplify the utility of this technology to obtain better postsurgical outcomes.

  10. Contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography in solid pseudopapillary neoplasm of the pancreas.

    PubMed

    Santhosh, Sampath; Lakshmanan, Ramesh Kumar; Sonik, Bhavay; Padmavathy, Rajagopalan; Gunaseelan, Rajamani Emmanuel

    2016-01-01

    Solid pseudopapillary neoplasm (SPN) of the pancreas is a rare pancreatic tumor with low malignant potential. It occurs characteristically more often in young women. Radiological and pathological studies have revealed that the tumor is quite different from other pancreatic tumors. Limited information is available in the literature reporting their accumulation of fluorine-(18) fluorodeoxyglucose ((18)F-FDG) in positron emission tomography/computed tomography (PET/CT). Here, we report a case of pancreatic SPN imaged with contrast-enhanced FDG PET/CT. A percutaneous fine needle aspiration from the metabolically active lesion revealed SPN, and it was confirmed with histopathological results. Recurrence or metastasis was not found after 7 months of follow-up.

  11. Contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography in solid pseudopapillary neoplasm of the pancreas

    PubMed Central

    Santhosh, Sampath; Lakshmanan, Ramesh Kumar; Sonik, Bhavay; Padmavathy, Rajagopalan; Gunaseelan, Rajamani Emmanuel

    2016-01-01

    Solid pseudopapillary neoplasm (SPN) of the pancreas is a rare pancreatic tumor with low malignant potential. It occurs characteristically more often in young women. Radiological and pathological studies have revealed that the tumor is quite different from other pancreatic tumors. Limited information is available in the literature reporting their accumulation of fluorine-18 fluorodeoxyglucose (18F-FDG) in positron emission tomography/computed tomography (PET/CT). Here, we report a case of pancreatic SPN imaged with contrast-enhanced FDG PET/CT. A percutaneous fine needle aspiration from the metabolically active lesion revealed SPN, and it was confirmed with histopathological results. Recurrence or metastasis was not found after 7 months of follow-up. PMID:27095862

  12. A rare cardiac haemangioma in the right ventricle diagnosed accurately using ¹⁸F-fluorodeoxyglucose-positron emission tomography.

    PubMed

    Matsuba, Tomoyuki; Hisashi, Yosuke; Yotsumoto, Goichi; Imoto, Yutaka

    2015-05-01

    A right ventricular cardiac tumour was incidentally detected in a 61-year-old man during a preoperative examination for coronary artery bypass grafting (CABG). Findings on computed tomography and magnetic resonance imaging suggested the differential diagnoses of myxoma, haemangioma and haemangiosarcoma, and it was difficult to identify whether the tumour was benign or malignant. (18)F-fluorodeoxyglucose-positron emission tomography strongly suggested a benign tumour. We enucleated the tumour, because an intraoperative frozen section also strongly suggested a benign origin. After resection, CABG under cardiopulmonary bypass was performed. Histopathological and immunohistochemical analysis indicated a cavernous haemangioma without evidence of malignant tissue. The patient has survived 20 months after surgery with no evidence of tumour recurrence.

  13. Are We Ready for Positron Emission Tomography/Computed Tomography-based Target Volume Definition in Lymphoma Radiation Therapy?

    SciTech Connect

    Yeoh, Kheng-Wei; Mikhaeel, N. George

    2013-01-01

    Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) has become indispensable for the clinical management of lymphomas. With consistent evidence that it is more accurate than anatomic imaging in the staging and response assessment of many lymphoma subtypes, its utility continues to increase. There have therefore been efforts to incorporate PET/CT data into radiation therapy decision making and in the planning process. Further, there have also been studies investigating target volume definition for radiation therapy using PET/CT data. This article will critically review the literature and ongoing studies on the above topics, examining the value and methods of adding PET/CT data to the radiation therapy treatment algorithm. We will also discuss the various challenges and the areas where more evidence is required.

  14. Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

    PubMed

    Fan, Audrey P; Jahanian, Hesamoddin; Holdsworth, Samantha J; Zaharchuk, Greg

    2016-05-01

    Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [(15)O]-water radiotracer. Although [(15)O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [(15)O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.

  15. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome.

    PubMed

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome.

  16. /sup 18/F-2-deoxy-2-fluoro-D-glucose as a tracer in the positron emission tomographic study of senile dementia

    SciTech Connect

    Farkas, T.; Ferris, S.H.; Wolf, A.P.; De Leon, M.J.; Christman, D.R.; Reisberg, B.; Alavi, A.; Fowler, J.S.; George, A.E.; Reivich, M.

    1982-03-01

    Using /sup 18/F-2-deoxy-2-fluoro-D-glucose as a tracer, the authors obtained positron emission tomographic scans of 11 patients with senile dementia and 6 age-matched controls. The rate of glucose metabolism was significantly lower in the patients with senile dementia and significantly correlated with the degree of cognitive impairment.

  17. Augmented myocardial perfusion reserve after coronary angioplasty quantified by positron emission tomography with H2(15)O

    SciTech Connect

    Walsh, M.N.; Geltman, E.M.; Steele, R.L.; Kenzora, J.L.; Ludbrook, P.A.; Sobel, B.E.; Bergmann, S.R. )

    1990-01-01

    Effects of coronary angioplasty on myocardial flow reserve have been difficult to characterize noninvasively because conventional imaging techniques cannot quantitate blood flow in absolute terms. The effects of coronary angioplasty on myocardial perfusion and perfusion reserve were delineated with positron emission tomography and oxygen-15-labeled water (H2(15)O) in 13 patients before and after single vessel angioplasty. In 11 patients, angioplasty was successful (minimal cross-sectional area increased from 0.60 +/- 0.59 to 3.45 +/- 1.09 mm2, p less than 0.001). In these patients, regional H2(15)O radioactivity (the ratio of nutritional perfusion in regions distal to the stenosis compared with regions supplied by angiographically normal arteries) at rest before angioplasty was 55 +/- 22% of peak myocardial radioactivity and did not increase significantly afterward (70 +/- 16%, p = NS). However, after administration of intravenous dipyridamole, hyperemic perfusion in regions distal to a stenosis averaged only 39 +/- 18% of peak myocardial counts before angioplasty, but increased to 66 +/- 22% after angioplasty (p less than 0.02). Perfusion reserve in the two patients in whom angioplasty was angiographically unsuccessful showed no change. Quantitative estimates of perfusion in absolute rather than relative terms were obtained with positron emission tomographic data from seven of the patients with successful angioplasty. At rest, perfusion in regions distal to a stenosis was not different from the values in regions supplied by normal coronary arteries (1.54 +/- 0.54 compared with 1.46 +/- 0.38 ml/g per min, p = NS).

  18. Mathematical modeling of positron emission tomography (PET) data to assess radiofluoride transport in living plants following petiolar administration

    DOE PAGES

    Converse, Alexander K.; Ahlers, Elizabeth O.; Bryan, Tom W.; ...

    2015-03-15

    Background: Ion transport is a fundamental physiological process that can be studied non-invasively in living plants with radiotracer imaging methods. Fluoride is a known phytotoxic pollutant and understanding its transport in plants after leaf absorption is of interest to those in agricultural areas near industrial sources of airborne fluoride. Here we report the novel use of a commercial, high-resolution, animal positron emission tomography (PET) scanner to trace a bolus of [¹⁸F]fluoride administered via bisected petioles of Brassica oleracea, an established model species, to simulate whole plant uptake of atmospheric fluoride. This methodology allows for the first time mathematical compartmental modelingmore » of fluoride transport in the living plant. Radiotracer kinetics in the stem were described with a single-parameter free- and trapped-compartment model and mean arrival times at different stem positions were calculated from the free-compartment time-activity curves. Results: After initiation of administration at the bisected leaf stalk, [¹⁸F] radioactivity climbed for approximately 10 minutes followed by rapid washout from the stem and equilibration within leaves. Kinetic modeling of transport in the stem yielded a trapping rate of 1.5 +/- 0.3%/min (mean +/- s.d., n = 3), velocity of 2.2 +/- 1.1 cm/min, and trapping fraction of 0.8 +/- 0.5%/cm. Conclusion: Quantitative assessment of physiologically meaningful transport parameters of fluoride in living plants is possible using standard positron emission tomography in combination with petiolar radiotracer administration. Movement of free fluoride was observed to be consistent with bulk flow in xylem, namely a rapid and linear change in position with respect to time. Trapping, likely in the apoplast, was observed. Future applications of the methods described here include studies of transport of other ions and molecules of interest in plant physiology.« less

  19. Suivi in situ de cultures tridimensionnelles en bioreacteur a perfusion grace a la tomographie d'emission par positrons

    NASA Astrophysics Data System (ADS)

    Chouinard, Julie

    The continuous assessment of developing tissue substitutes is crucial to understand their evolution over time. However, this represents quite a challenge when thick samples must be evaluated with standard microscopy techniques. Common characterization methods are time consuming and usually result in the destruction of the culture. Real-time, in situ, non-invasive and non-destructives methods are needed to monitor the growth of large non-transparent constructs in tissue engineering. Medical imaging modalities, which can provide information on the structure and function of internal organs and tissues in living organisms, have the potential of allowing repetitive monitoring of these 3D cultures in vitro. The working hypothesis of this thesis was to establish standard noninvasive and nondestructive real-time bioreactor imaging protocols for in situ monitoring of the viability and metabolism of endothelial cells when grown in perfused 3D fibrin gel scaffolds. To achieve this goal, a culture chamber with hollow fibers was designed and a pulsatile perfusion bioreactor system, able to promote cell survival and proliferation, was constructed and validated. Standard imaging protocols in Positron Emission Tomography (PET) are not adapted to image bioreactor systems. A suitable method had to be devised using the well-known radiotracer 18F-fluorodeoxyglucose ( 18FDG), a marker of glucose metabolism. Optimal uptake conditions were determined using cell monolayers and the best parameters were then applied on perfused 3D cultures to evaluate perfusion, cell viability and emerging cell structures. After only 12 hours of culture, the cell density could be estimated and cell structures were localized within the fibrin gels after 1-2 weeks of culture. PET is a promising tool for tissue engineering with many specific tracers available that might eventually be able to reveal new information on tissue development. Key words: Endothelial cells, Perfusion bioreactor, Positron Emission

  20. Predictive value of dobutamine echocardiography and positron emission tomography in identifying hibernating myocardium in patients with postischaemic heart failure

    PubMed Central

    Pagano, D; Bonser, R; Townend, J; Ordoubadi, F; Lorenzoni, R; Camici, P

    1998-01-01

    Objective—To compare the predictive value of dobutamine echocardiography (DE) and positron emission tomography (PET) in identifying reversible chronic left ventricular (LV) dysfunction (hibernating myocardium) in patients with coronary artery disease (CAD) and overt heart failure.
Patients—30 patients (four women) with CAD and heart failure undergoing coronary artery bypass grafting (CABG).
Methods—Myocardial viability was assessed with DE (5 and 10 µg/kg/min) and PET with [18F] 2-fluoro-2-deoxy-D-glucose (FDG) under hyperinsulinaemic euglycaemic clamp. Regional (echo) and global LV function (MUGA) were assessed at baseline and six months after CABG.
Results—192 of the 336 (57%) dysfunctional LV segments improved function following CABG (hibernating) and the LV ejection fraction (EF) increased from 23(7) to 32(9)% (p < 0.0001) (in 17 patients > 5%). DE and PET had similar positive predictive values (68% and 66%) in the identification of hibernating myocardium, but DE had a significantly lower negative predictive value than PET (54% v 96%; p < 0.0001). A significant linear correlation was found between the number of PET viable segments and the changes in EF following CABG (r = 0.65; p = 0.0001). Stepwise logistic regression identified the number of PET viable segments as an independent predictor of improvement in EF > 5%, whereas the number of DE viable segments, the baseline LVEF, and wall motion were not.
Conclusions—DE has a higher false negative rate than PET in identifying recoverable LV dysfunction in patients with severe postischaemic heart failure. The amount of PET viable myocardium correlates with the functional outcome following CABG.

 Keywords: dobutamine echocardiography;  positron emission tomography;  coronary artery disease;  heart failure;  hibernating myocardium PMID:9602663

  1. Mathematical modeling of positron emission tomography (PET) data to assess radiofluoride transport in living plants following petiolar administration

    SciTech Connect

    Converse, Alexander K.; Ahlers, Elizabeth O.; Bryan, Tom W.; Hetue, Jackson D.; Lake, Katherine A.; Ellison, Paul A.; Engle, Jonathan W.; Barnhart, Todd E.; Nickles, Robert J.; Williams, Paul H.; DeJesus, Onofre T.

    2015-03-15

    Background: Ion transport is a fundamental physiological process that can be studied non-invasively in living plants with radiotracer imaging methods. Fluoride is a known phytotoxic pollutant and understanding its transport in plants after leaf absorption is of interest to those in agricultural areas near industrial sources of airborne fluoride. Here we report the novel use of a commercial, high-resolution, animal positron emission tomography (PET) scanner to trace a bolus of [¹⁸F]fluoride administered via bisected petioles of Brassica oleracea, an established model species, to simulate whole plant uptake of atmospheric fluoride. This methodology allows for the first time mathematical compartmental modeling of fluoride transport in the living plant. Radiotracer kinetics in the stem were described with a single-parameter free- and trapped-compartment model and mean arrival times at different stem positions were calculated from the free-compartment time-activity curves. Results: After initiation of administration at the bisected leaf stalk, [¹⁸F] radioactivity climbed for approximately 10 minutes followed by rapid washout from the stem and equilibration within leaves. Kinetic modeling of transport in the stem yielded a trapping rate of 1.5 +/- 0.3%/min (mean +/- s.d., n = 3), velocity of 2.2 +/- 1.1 cm/min, and trapping fraction of 0.8 +/- 0.5%/cm. Conclusion: Quantitative assessment of physiologically meaningful transport parameters of fluoride in living plants is possible using standard positron emission tomography in combination with petiolar radiotracer administration. Movement of free fluoride was observed to be consistent with bulk flow in xylem, namely a rapid and linear change in position with respect to time. Trapping, likely in the apoplast, was observed. Future applications of the methods described here include studies of transport of other ions and molecules of interest in plant physiology.

  2. The predictive role of interim positron emission tomography for Hodgkin lymphoma treatment outcome is confirmed using the interpretation criteria of the Deauville five-point scale.

    PubMed

    Gallamini, Andrea; Barrington, Sally F; Biggi, Alberto; Chauvie, Stephane; Kostakoglu, Lale; Gregianin, Michele; Meignan, Michel; Mikhaeel, George N; Loft, Annika; Zaucha, Jan M; Seymour, John F; Hofman, Michael S; Rigacci, Luigi; Pulsoni, Alessandro; Coleman, Morton; Dann, Eldad J; Trentin, Livio; Casasnovas, Olivier; Rusconi, Chiara; Brice, Pauline; Bolis, Silvia; Viviani, Simonetta; Salvi, Flavia; Luminari, Stefano; Hutchings, Martin

    2014-06-01

    A retrospective, international, multicenter study was undertaken to assess: (i) the prognostic role of 'interim' positron emission tomography performed during treatment with doxorubicin, bleomycin, vinblastine and dacarbazine in patients with Hodgkin lymphoma; and (ii) the reproducibility of the Deauville five-point scale for the interpretation of interim positron emission tomography scan. Two hundred and sixty patients with newly diagnosed Hodgkin lymphoma were enrolled. Fifty-three patients with early unfavorable and 207 with advanced-stage disease were treated with doxorubicin, bleomycin, vinblastine and dacarbazine ± involved-field or consolidation radiotherapy. Positron emission tomography scan was performed at baseline and after two cycles of chemotherapy. Treatment was not changed according to the results of the interim scan. An international panel of six expert reviewers independently reported the scans using the Deauville five-point scale, blinded to treatment outcome. Forty-five scans were scored as positive (17.3%) and 215 (82.7%) as negative. After a median follow up of 37.0 (2-110) months, 252 patients are alive and eight have died. The 3-year progression-free survival rate was 83% for the whole study population, 28% for patients with interim positive scans and 95% for patients with interim negative scans (P<0.0001). The sensitivity, specificity, and negative and positive predictive values of interim positron emission tomography scans for predicting treatment outcome were 0.73, 0.94, 0.94 and 0.73, respectively. Binary concordance amongst reviewers was good (Cohen's kappa 0.69-0.84). In conclusion, the prognostic role and validity of the Deauville five-point scale for interpretation of interim positron emission tomography scans have been confirmed by the present study.

  3. Measurement of radiation dose to the thyroid using positron emission tomography.

    PubMed

    Ott, R J; Batty, V; Webb, B S; Flower, M A; Leach, M O; Clack, R; Marsden, P K; McCready, V R; Bateman, J E; Sharma, H

    1987-03-01

    Measurements of the functioning volume of thyroid tissue have been made in 22 patients undergoing radioiodine therapy for thyrotoxicosis, using a prototype multiwire proportional counter positron camera. Tomographic images were produced of the distribution of 124I in the thyroid. Functioning volumes were found to be in the range 21-79 cm3 with volume errors of the order of +/- 4% to +/- 14%. Radioiodine uptake varied from 28% to 98%. Using a value of 6 days for the effective half-life of radioiodine in hyperactive thyroids, radiation doses from a standard therapy administration of 75 MBq of 131I varied from 11 to 48 Gy (compared with a recommended 50-70 Gy). In five cases PET imaging showed a non-uniform distribution of radioiodine in thyroids thought to have uniform uptake from conventional pinhole scintigraphy.

  4. Final Report Summary: Radiation dosimetry of Cu-64-labeled radiotherapy agents using PET [Positron Emission Tomography

    SciTech Connect

    Anderson, Carolyn J.; Cutler, P.D.

    2002-09-01

    This project began in 1996, and was completed in July 2001. The overall goals were to compare various methods of dosimetry of PET imaging agents, as well as develop more optimal methods. One of the major accomplishments of this grant was the human PET imaging studies of a positron-emitting radiopharmaceutical for somatostatin-receptor imaging, and subsequent dosimetry calculations resulting from this study. In addition, we collaborated with Darrell Fisher and Edmund Hui to develop a MIRD-hamster program for calculating hamster organ and tumor dosimetry in hamster models. Progress was made towards a point kernel approach to more accurately determining absorbed doses to normal organs, as well as towards co-registration of PET and MRI images. This report focuses on the progress made in the last 15 months of the grant, which in general is a summary of the progress over the 5 years the project was ongoing.

  5. Evidence for a caudate role in aphasia from FDG positron emission tomography

    SciTech Connect

    Metter, E.J.; Riege, W.H.; Hanson, W.R.; Phelps, M.; Kuhl, D.E.

    1982-01-01

    In a recent study correlations between language function and regional glucose metabolism from FDG positron computed tomography were examined. Caudate metabolism correlated with PICA speaking and comprehension factors, as well as BDAE mean writing and reading scores. To identify the language function implicated with caudate metabolism in these eleven patients, twenty subtests making up these two PICA factors and mean BDAE scores were correlated to caudate metabolism. Also a principle components analysis on the twenty subtests identified three factors, only one of which correlated with caudate metabolism. Evidence was found that the caudate has a functional relationship to recognition or motor planning of simple and overlearned materials. This involved simple syntax, low levels of abstraction, identification or sequencing of phonetic and semantic material. This role appeared related to but independent of Broca and frontal lobe function, and may involve the focusing of cortical functions, by allowing two or more regions to interact together.

  6. Positron emission reconstruction tomography for the assessment of regional myocardial metabolism by the administration of substrates labeled with cyclotron produced radionuclides

    NASA Technical Reports Server (NTRS)

    Ter-Pogossian, M. M.; Hoffman, E. J.; Weiss, E. S.; Coleman, R. E.; Phelps, M. E.; Welch, M. J.; Sobel, B. E.

    1975-01-01

    A positron emission transverse tomograph device was developed which provides transaxial sectional images of the distribution of positron-emitting radionuclides in the heart. The images provide a quantitative three-dimensional map of the distribution of activity unencumbered by the superimposition of activity originating from regions overlying and underlying the plane of interest. PETT is used primarily with the cyclotron-produced radionuclides oxygen-15, nitrogen-13 and carbon-11. Because of the participation of these atoms in metabolism, they can be used to label metabolic substrates and intermediary molecules incorporated in myocardial metabolism.

  7. Carbon-11 and fluorine-18 chemistry devoted to molecular probes for imaging the brain with positron emission tomography.

    PubMed

    Dollé, Frédéric

    2013-01-01

    Exploration of the living human brain in real-time and in a noninvasive way was for centuries only a dream, made, however, possible today with the remarkable development during the four last decades of powerful molecular imaging techniques, and especially positron emission tomography (PET). Molecular PET imaging relies, from a chemical point of view, on the use and preparation of a positron-emitting radiolabelled probe or radiotracer, notably compounds incorporating one of two short-lived radionuclides fluorine-18 (T1/2 : 109.8 min) and carbon-11 (T1/2 : 20.38 min). The growing availability and interest for the radiohalogen fluorine-18 in radiopharmaceutical chemistry undoubtedly results from its convenient half-life and the successful use in clinical oncology of 2-[(18) F]fluoro-2-deoxy-d-glucose ([(18) F]FDG). The special interest of carbon-11 is not only that carbon is present in virtually all biomolecules and drugs allowing therefore for isotopic labelling of their chemical structures but also that a given molecule could be radiolabelled at different functions or sites, permitting to explore (or to take advantage of) in vivo metabolic pathways. PET chemistry includes production of these short-lived radioactive isotopes via nuclear transmutation reactions using a cyclotron, and is directed towards the development of rapid synthetic methods, at the trace level, for the introduction of these nuclides into a molecule, as well as the use of fast purification, analysis and formulation techniques. PET chemistry is the driving force in molecular PET imaging, and this special issue of the Journal of Labelled Compounds and Radiopharmaceuticals, which is strongly chemistry and radiochemistry-oriented, aims at illustrating, be it in part only, the state-of-the-art arsenal of reactions currently available and its potential for the research and development of specific molecular probes labelled with the positron emitters carbon-11 and fluorine-18, with optimal imaging

  8. Positron emission tomography and [18F]BPA: a perspective application to assess tumour extraction of boron in BNCT.

    PubMed

    Menichetti, L; Cionini, L; Sauerwein, W A; Altieri, S; Solin, O; Minn, H; Salvadori, P A

    2009-07-01

    Positron emission tomography (PET) has become a key imaging tool in clinical practice and biomedical research to quantify and study biochemical processes in vivo. Physiologically active compounds are tagged with positron emitters (e.g. (18)F, (11)C, (124)I) while maintaining their biological properties, and are administered intravenously in tracer amounts (10(-9)-10(-12)M quantities). The recent physical integration of PET and computed tomography (CT) in hybrid PET/CT scanners allows a combined anatomical and functional imaging: nowadays PET molecular imaging is emerging as powerful pharmacological tool in oncology, neurology and for treatment planning as guidance for radiation therapy. The in vivo pharmacokinetics of boron carrier for BNCT and the quantification of (10)B in living tissue were performed by PET in the late nineties using compartmental models based on PET data. Nowadays PET and PET/CT have been used to address the issue of pharmacokinetic, metabolism and accumulation of BPA in target tissue. The added value of the use of L-[(18)F]FBPA and PET/CT in BNCT is to provide key data on the tumour extraction of (10)B-BPA versus normal tissue and to predict the efficacy of the treatment based on a single-study patient analysis. Due to the complexity of a binary treatment like BNCT, the role of PET/CT is currently to design new criteria for patient enrolment in treatment protocols: the L-[(18)F]BPA/PET methodology could be considered as an important tool in newly designed clinical trials to better estimate the concentration ratio of BPA in the tumour as compared to neighbouring normal tissues. Based on these values for individual patients the decision could be made whether BNCT treatment could be advantageous due to a selective accumulation of BPA in an individual tumour. This approach, applicable in different tumour entities like melanoma, glioblastoma and head and neck malignancies, make this methodology as reliable prognostic and therapeutic indicator for

  9. Development and Operation of a High Resolution Positron Emission Tomography System to Perform Metabolic Studies on Small Animals.

    NASA Astrophysics Data System (ADS)

    Hogan, Matthew John

    A positron emission tomography system designed to perform high resolution imaging of small volumes has been characterized. Two large area planar detectors, used to detect the annihilation gamma rays, formed a large aperture stationary positron camera. The detectors were multiwire proportional chambers coupled to high density lead stack converters. Detector efficiency was 8%. The coincidence resolving time was 500 nsec. The maximum system sensitivity was 60 cps/(mu)Ci for a solid angle of acceptance of 0.74(pi) St. The maximum useful coincidence count rate was 1500 cps and was limited by electronic dead time. Image reconstruction was done by performing a 3-dimensional deconvolution using Fourier transform methods. Noise propagation during reconstruction was minimized by choosing a 'minimum norm' reconstructed image. In the stationary detector system (with a limited angle of acceptance for coincident events) statistical uncertainty in the data limited reconstruction in the direction normal to the detector surfaces. Data from a rotated phantom showed that detector rotation will correct this problem. Resolution was 4 mm in planes parallel to the detectors and (TURN)15 mm in the normal direction. Compton scattering of gamma rays within a source distribution was investigated using both simulated and measured data. Attenuation due to scatter was as high as 60%. For small volume imaging the Compton background was identified and an approximate correction was performed. A semiquantitative blood flow measurement to bone in the leg of a cat using the ('18)F('-) ion was performed. The results were comparable to investigations using more conventional techniques. Qualitative scans using ('18)F labelled deoxy -D-glucose to assess brain glucose metabolism in a rhesus monkey were also performed.

  10. Positron emission tomography in the newborn: extensive impairment of regional cerebral blood flow with intraventricular hemorrhage and hemorrhagic intracerebral involvement

    SciTech Connect

    Volpe, J.J.; Herscovitch, P.; Perlman, J.M.; Raichle, M.E.

    1983-11-01

    Positron emission tomography (PET) now provides the capability of measuring regional cerebral blood flow with high resolution and little risk. In this study, we utilized PET in six premature infants (920 to 1,200 g) with major intraventricular hemorrhage and hemorrhagic intracerebral involvement to measure regional cerebral blood flow during the acute period (5 to 17 days of age). Cerebral blood flow was determined after intravenous injection of H/sub 2/O, labeled with the positron-emitting isotope, /sup 15/O. Findings were similar and dramatic in all six infants. In the area of hemorrhagic intracerebral involvement, little or no cerebral blood flow was detected. However, in addition, surprisingly, a marked two- to fourfold reduction in cerebral blood flow was observed throughout the affected hemisphere, well posterior and lateral to the intracerebral hematoma, including cerebral white matter and, to a lesser extent, frontal, temporal, and parietal cortex. In the one infant studied a second time, ie, at 3 months of age, the extent and severity of the decreased cerebral blood flows in the affected hemisphere were similar to those observed on the study during the neonatal period. At the three autopsies, the affected left hemisphere showed extensive infarction, corroborating the PET scans. These observations, the first demonstration of the use of PET in the determination of regional cerebral blood flow in the newborn, show marked impairments in regional cerebral blood flow in the hemisphere containing an apparently restricted intracerebral hematoma, indicating that the hemorrhagic intracerebral involvement is only a component of a much larger lesion, ischemic in basic nature, ie, an infarction. This large ischemic lesion explains the poor neurologic outcome in infants with intraventricular hemorrhage and hemorrhagic intracerebral involvement.