Science.gov

Sample records for 24-hour holter monitoring

  1. Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring

    PubMed Central

    Barrett, Paddy M.; Komatireddy, Ravi; Haaser, Sharon; Topol, Sarah; Sheard, Judith; Encinas, Jackie; Fought, Angela J.; Topol, Eric J.

    2013-01-01

    BACKGROUND Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration–cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar’s tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring. PMID:24384108

  2. [Identification of paroxysmal, transient arrhythmias: Intermittent registration more efficient than the 24-hour Holter monitoring].

    PubMed

    Hendrikx, Tijn; Rosenqvist, Mårten; Sandström, Herbert; Persson, Mats; Hörnsten, Rolf

    2015-01-06

    Many patients suffer from palpitations or dizziness/presyncope. These patients are often referred for Holter ECG (24 hour), although the sensitivity for detecting arrhythmias is low. A new method, short intermittent regular and symptomatic ECG registrations at home, might be a convenient and more sensitive alternative also suitable for primary health care. In this case report we present a patient who had contacted health care several times during a seven year period for paroxysmal palpitations. Routine examination with 24 hour Holter ECG and event recorder did not result in a diagnosis. Using intermittent handheld ECG registration at home, a paroxysmal supraventricular arrhythmia was diagnosed. Further investigation revealed that the patient had a concealed Wolff-Parkinson-White (WPW) syndrome.

  3. Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias

    PubMed Central

    2014-01-01

    Background Many patients report symptoms of palpitations or dizziness/presyncope. These patients are often referred for 24-hour Holter ECG, although the sensitivity for detecting relevant arrhythmias is comparatively low. Intermittent short ECG recording over a longer time period might be a convenient and more sensitive alternative. The objective of this study is to compare the efficacy of 24-hour Holter ECG with intermittent short ECG recording over four weeks to detect relevant arrhythmias in patients with palpitations or dizziness/presyncope. Methods Design: prospective, observational, cross-sectional study. Setting: Clinical Physiology, University Hospital. Patients: 108 consecutive patients referred for ambiguous palpitations or dizziness/presyncope. Interventions: All individuals underwent a 24-hour Holter ECG and additionally registered 30-second handheld ECG (Zenicor EKG® thumb) recordings at home, twice daily and when having cardiac symptoms, during 28 days. Main outcome measures: Significant arrhythmias: atrial fibrillation (AF), paroxysmal supraventricular tachycardia (PSVT), atrioventricular (AV) block II–III, sinus arrest (SA), wide complex tachycardia (WCT). Results 95 patients, 42 men and 53 women with a mean age of 54.1 years, completed registrations. Analysis of Holter registrations showed atrial fibrillation (AF) in two patients and atrioventricular (AV) block II in one patient (= 3.2% relevant arrhythmias [95% CI 1.1–8.9]). Intermittent handheld ECG detected nine patients with AF, three with paroxysmal supraventricular tachycardia (PSVT) and one with AV-block-II (= 13.7% relevant arrhythmias [95% CI 8.2–22.0]). There was a significant difference between the two methods in favour of intermittent ECG with regard to the ability to detect relevant arrhythmias (P = 0.0094). With Holter ECG, no symptoms were registered during any of the detected arrhythmias. With intermittent ECG, symptoms were registered during half of the arrhythmia

  4. [Electrocardiographic recording of long duration (Holter) of 24 hours during idiopathic cardiomyopathy of the peripartum].

    PubMed

    Diao, M; Diop, I B; Kane, A; Camara, S; Kane, Ad; Sarr, M; Ba, S A; Diouf, S M

    2004-01-01

    The idiopathic myocardiopathy of the peripartum (IMPP) is a frequent disease in the Soudano-Sahelian zone of Africa whose evolution is loaded with many complications hemodynamic, thrombo-embolic and rhythmic. The prevalence and the meaning of the rhythm disorders are unknown. The aims of this prospective study are to measure and to describe the prevalence of the anomalies observed in Holter ECG of 24 hours. It's about a description cross-sectional study realized at the Cardiology Department (CHU Dakar) and 19 patients with IMPP were included, from October 2000 to July 2002. A recording ECG of 24 hours (Holter) was realized on all the patients. The average age was 29.4+/-6.9 years with a low socio-economic level (100%). The diagnosis of IMPP done before childbirth in 4 cases (21%) and the post partum on 15 patients (78.9%). The dyspnea was constant, the chest pain in 12 cases (63.1%) and palpitations in 8 cases (42%). The average rate of hemoglobin was of 10.85+/-2.05 g/dL. The standard electrocardiogram recorded a sinusal tachycardia (68.4%), a cavitary hypertrophy (78.8%), and disorders of the repolarization (47.3%). The cardiac echo-Doppler noted a cavitary dilatation (84.2%), a constant alteration of the left ventricular systolic function with a fraction of average ejection of 29.7+/-10.3%. The anatomy of the valves was normal. The recording Holter ECG of 24 hours recorded a sinusal tachycardia in 17 cases (89.4%), ventricular extrasystoles on 7 patients (36.8%), 4 cases of ventricular tachycardia non-sustained and double ventricular extrasystole on 1 patient, auricular extrasystoles in 4 cases (21%) and 1 case of auriculo-ventricular block of the first degree. The study of heart rate variability founded a mean value of 106 ms.

  5. Sudden cardiac arrest risk stratification based on 24-hour Holter ECG statistics.

    PubMed

    Kasahara, Keisuke; Shiobara, Masahito; Nakamura, Saya; Yamashiro, Koichiro; Yana, Kazuo; Ono, Takuya

    2015-08-01

    This study examined the feasibility of using indices obtained from a long term Holter ECG record for sudden cardiac arrest (SCA) risk stratification. The ndices tested were the QT-RR interval co-variability and the alternans ratio percentile (ARP(θ)) which is defined as the θ(th) percentile of alternans ratios over a 24 hour period. The QT-RR interval co-variabilities are evaluated by the serial correlation coefficient between QT and RR trend sequences (QTRC). Previously reported Kalman filter technique and a simple smoothing spline method for the trend estimation are compared. Parameter θ in the alternans ratio percentile index was optimized to achieve the best classification accuracy. These indices were estimated from 26 cardiovascular outpatients for Holter ECG record. Patients were classified into high and low risk groups according to their clinical diagnosis, and the obtained indices were compared with those of 25 control subjects. A risk stratification using the two indices QTRC and ARP(θ) yielded an average sensitivity of 0.812 and a specificity of 0.925. The sensitivities and specificities of all three categories exceeded 0.8 except for the sensitivity to detect the high-risk patient group. Other short-term ECG parameters may need to be incorporated in order to improve the sensitivity.

  6. Holter and Event Monitors

    MedlinePlus

    ... Holter and event monitors are similar to an EKG (electrocardiogram). An EKG is a simple test that detects and records ... for diagnosing heart rhythm problems. However, a standard EKG only records the heartbeat for a few seconds. ...

  7. Holter monitor (24h)

    MedlinePlus

    Electrodes (small conducting patches) are stuck onto your chest. These are attached by wires to a small ... can match them with your Holter monitor findings. Electrodes must be firmly attached to the chest so ...

  8. [Gastroesophageal reflux during pregnancy: 24-hour esophageal ph monitoring].

    PubMed

    Anton, C; Anton, E; Drug, V; Stanciu, C

    2001-01-01

    Gastroesophageal reflux (GER) occurs in 30-50% of all pregnancies. The progressive rise in plasma progesterone has been suggested as a possible mediator of GER during pregnancy. Recent advances in technology have made it possible to detect GER through monitoring of esophageal pH for prolonged periods, including sleep. 24-hour pH monitoring is the proper method for diagnosing GER in pregnant women. If 24-hour esophageal pH monitoring is to be a useful diagnostic tool, it must reliably discriminate GER patients despite daily variations in distal esophageal acid exposure. To address this issue, we studied 62 women (30 healthy non-pregnant women without GER symptoms and 32 pregnant women with GER symptoms-heartburn, acid regurgitation) with 24-hour esophageal pH monitoring. Intrasubject reproducibility of three pH parameters to discriminate the presence of abnormal acid reflux was determined (DeMeester score, Kaye score, circadian one hour diagram for pH < 4). Each patient was interviewed, using a reliable questionnaire detailing individual habits, life style characteristics and symptoms, at four time points during the first, second, third trimesters of pregnancy and post-partum period. Symptoms of GER are common in pregnancy and although GER rarely endangers maternal or fetal health, it can significantly affect patient comfort and quality of life. We conclude: 1. GER is almost constantly present during pregnancy, increasing with gestational age. 2. The most important pH--parameter is DeMcester score. 3. Heartburn disappear after delivery. 4. 24-hour esophageal pH monitoring is the gold standard for measuring acid exposure and is a reproducible test for the diagnosis of GER in pregnancy.

  9. Heart rate variability parameters of myxomatous mitral valve disease in dogs with and without heart failure obtained using 24-hour Holter electrocardiography.

    PubMed

    Oliveira, M S; Muzzi, R A L; Araújo, R B; Muzzi, L A L; Ferreira, D F; Nogueira, R; Silva, E F

    2012-06-16

    Time-domain heart rate variability (HRV) parameters and the correlation between echocardiography and Holter examinations in dogs with myxomatous mitral valve disease (MMVD) were determined. Holter examination was also performed at different time frames: an entire 24-hour period, a four-hour period during sleep, and a four-hour period while awake. Ten healthy (control group) and 28 MMVD dogs, 15 with and 13 without heart failure, were evaluated. The SDANN (sd of the mean normal RR intervals for all five-minute segments during 24-hour Holter) and pNN(50) (percentage of differences between adjacent normal RR intervals that are >50 ms computed over 24-hour Holter) variables were significantly lower in the dogs with MMVD heart failure. The differences in HRV between the groups were only detected during the 24-hour evaluation period (P<0.05). There were high correlations (canonical analysis) between Holter and echocardiography examinations when considering pNN(50), SDANN, and LA/AO (left atrial to aortic root ratio) (r=0.92; P<0.05), indicating that both are important in evaluating MMVD dogs. SDANN and pNN(50) are measures of parasympathetic control of the heart, and thus, it is possible to infer that the MMVD dogs exhibit parasympathetic withdrawal during the development of heart failure.

  10. A 24-HOUR AMBULATORY ECG MONITORING IN ASSESSMENT OF QT INTERVAL DURATION AND DISPERSION IN ROWERS WITH PHYSIOLOGICAL MYOCARDIAL HYPERTROPHY

    PubMed Central

    Kim, Z.F.; Bilalova, R.R.; Tsibulkin, N.A.; Almetova, R.R.; Mudarisova, R.R.; Ahmetov, I.I.

    2013-01-01

    Myocardial hypertrophy (MH) due to cardiac pathology is characterized by an increase in QT interval duration and dispersion, while the findings for exercise-induced myocardial hypertrophy are contradictory. The majority of published research findings have not explored this relationship, but there have only been a few conducted studies using 24-hour ECG monitoring. The aim of the study was to determine the QT interval duration and dispersion in short-term and 24-hour ECG in endurance athletes with myocardial hypertrophy and without it. Methods: A total of 26 well-trained rowers underwent a resting 12-lead ECG, 24-hour ECG monitoring and echocardiography. Results: Athletes with MH (n = 7) at rest did not show any increase in QTc interval duration and dispersion, or mean and maximal QTc duration in Holter monitoring compared to athletes without MH (n = 19). Left ventricular mass was not significantly correlated with any QTc characteristics. Furthermore, athletes with MH had significantly longer mean QT (P = 0.01) and maximal QT (P = 0.018) intervals in Holter monitoring and higher 24-hour heart rate variability indexes due to stronger vagal effects. Conclusions: The present study demonstrated that athlete's heart syndrome with myocardial hypertrophy as a benign phenomenon does not lead to an increase in QT interval duration, or increases in maximal and mean duration in a 24-hour ECG. An increase in QT interval duration in athletes may have an autonomic nature. PMID:24744494

  11. Holter monitoring: are two days better than one?

    NASA Technical Reports Server (NTRS)

    McClennen, S.; Zimetbaum, P. J.; Ho, K. K.; Goldberger, A. L.

    2000-01-01

    The optimal duration of Holter monitoring (HM) to minimize costs and maximize yield is unknown. In a retrospective review of 164 patients referred to a tertiary care center for evaluation with 2 days of HM, we found that 48 hours was not cost effective when compared with the traditional 24-hour period.

  12. [Holter monitoring data in children with gastroesophageal reflux disease].

    PubMed

    Apenchenko, Iu S; Shcherbakov, P L; Gnusaev, S F; Ivanova, I I; Rozov, D N

    2014-01-01

    The aim of research is to estimate the functional state of the cardiovascular system in children with gastroesophageal reflux disease (GERD) with the help of Holter monitoring. 117 children of school age were examined: 69 children with GERD and 48 children with chronic gastroduodenitis. All children passed esophagogastroduodenoscopy, 24-hour pH-monitoring, electrocardiography and Holter monitoring. According to Holter monitoring data it was revealed that children with GERD had increased low-frequency components of frequency domain analyses, increased number of nocturnal PVCs and increased time of enhanced dispertion periods. Holter monitoring in patients with GERD can be used to detect preclinical ectopic rhythm, to evaluate autonomic dysfunction by frequency domain analyses, to predict nocturnal symptoms.

  13. Relative prognostic value of rest thallium-201 imaging, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring after acute myocardial infarction

    SciTech Connect

    Hakki, A.H.; Nestico, P.F.; Heo, J.; Unwala, A.A.; Iskandrian, A.S.

    1987-07-01

    Rest thallium-201 scintigraphy, radionuclide ventriculography and 24 hour Holter monitoring are acceptable methods to assess myocardial necrosis, performance and electrical instability. This study examined the relative value of the three tests, when obtained a mean of 7 days after acute myocardial infarction, in predicting 1 year mortality in 93 patients. Planar thallium-201 images were obtained in three projections and were scored on a scale of 0 to 4 in 15 segments (normal score = 60). Patients were classified as having high risk test results as follows: thallium score less than or equal to 45 (33 patients), left ventricular ejection fraction less than or equal to 40% (51 patients) and complex ventricular arrhythmias on Holter monitoring (36 patients). During the follow-up of 6.4 +/- 3.4 months (mean +/- SD), 15 patients died of cardiac causes. All three tests were important predictors of survival by univariate Cox survival analysis; the thallium score, however, was the only important predictor by multivariate analysis. The predictive power of the thallium score was comparable with that of combined ejection fraction and Holter monitoring (chi-square = 21 versus chi-square = 22). Thus, rest thallium-201 imaging performed before hospital discharge provides important prognostic information in survivors of acute myocardial infarction which is comparable with that provided by left ventricular ejection fraction and Holter monitoring. Patients with a lower thallium score (large perfusion defects) are at high risk of cardiac death during the first year after infarction.

  14. 24 hour blood pressure monitoring in healthy and hypertensive children.

    PubMed Central

    Reusz, G S; Hóbor, M; Tulassay, T; Sallay, P; Miltényi, M

    1994-01-01

    24 Hour ambulatory blood pressure monitoring (ABPM) was performed to provide data on the normal daily blood pressure of healthy schoolchildren and on patients with hypertension. The subjects studied were 123 healthy schoolchildren with a mean (SD) age of 12.5 (1.6) years (range 9.5-14.5 years), 24 children with borderline or mild hypertension, 17 with renal hypertension and normal renal function, 10 with chronic renal failure, and six with a renal allograft. In eight children with definite renal disease a second measurement was performed after treatment modification. The monitor used for ABPM was validated with a mercury column manometer. The mean (SD) of the signed differences of the blood pressure measured by the two methods was -0.19 (1.75) mmHg for the systolic and -0.21 (2.11) mmHg for the diastolic blood pressure (n = 60). Normal values for daytime and night time blood pressure were determined for those aged 10-14 years. The mean (SD) blood pressure of the 123 children was 109 (7)/66 (8) mmHg (systolic/diastolic) for the daytime and 96 (8)/52 (7) mmHg at night time. Of the 24 children with borderline or mild hypertension 14 had a raised blood pressure on ABPM. The circadian rhythm was disturbed in three children of this group. Even children with normal daytime blood pressure had significantly higher systolic blood pressure in the night when compared with the controls. The incidence of disturbed circadian rhythm was higher in the groups with renal hypertension (4/17 in the subgroup with normal renal function, 5/16 in the group with renal failure and/or transplantation). All children undergoing a second ABPM measurement had a lower average blood pressure after treatment adjustment. ABPM measurements were reproducible and accurate. The method provided new data on the physiological circadian variation of blood pressure in healthy children. It proved to be a helpful tool in the diagnosis of hypertension, particularly in the detection of cases of disturbance of the

  15. Evaluation of the indications and arrhythmic patterns of 24 hour Holter electrocardiography among hypertensive and diabetic patients seen at OAUTHC, Ile-Ife Nigeria

    PubMed Central

    Adebayo, Rasaaq A; Ikwu, Amanze N; Balogun, Michael O; Akintomide, Anthony O; Mene-Afejuku, Tuoyo O; Adeyeye, Victor O; Bamikole, Olaniyi J; Bisiriyu, Luqman A; Ajayi, Olufemi E; Ogunyemi, Suraj A; Oketona, Omolola A

    2014-01-01

    Background There are very limited published studies in Nigeria on the use of 24 hour Holter electrocardiogram (Holter ECG) in the arrhythmic evaluation of hypertensive and diabetic patients. Objective To evaluate indications, arrhythmic pattern of Holter ECG, and heart rate variability (HRV) among patients with hypertensive heart disease (HHD) with or without heart failure and type 2 diabetes mellitus (T2DM) seen in our cardiac care unit. Methods Seventy-nine patients (32 males and 47 females) were studied consecutively over a year using Schiller type (MT-101) Holter ECG machine. Results Out of the 79 patients, 17 (21.5%) had HHD without heart failure, 33 (41.8%) had HHD with hypertensive heart failure (HHF), while 29 (36.7%) were T2DM patients. The mean (standard deviation) ages of HHD without heart failure, HHF and T2DM patients were 59.65 (±14.38), 65.15 (±14.30), and 54.66 (±8.88) respectively. The commonest indication for Holter ECG was palpitation (38%), followed by syncope (20.3%). Premature ventricular contraction was the commonest arrhythmic pattern among the 79 patients, especially among HHF patients. The HRV using standard deviation of all normal-normal intervals was significantly reduced in T2DM patients (81.03±26.33, confidence interval [CI] =71.02–91.05) compared to the HHD without heart failure (119.65±29.86, CI =104.30–135.00) and HHF (107.03±62.50, CI =84.00–129.19). There was a negative correlation between the duration of T2DM and HRV (r=−0.613). Conclusion Palpitation was the commonest Holter ECG indication and premature ventricular contractions were the commonest arrhythmic pattern among our patients. HRV was reduced in T2DM patients compared with hypertensive patients. PMID:25473303

  16. [The incidence of arrhythmias in young persons without demonstrable heart disease: a 24-hour Holter study in 100 medical students].

    PubMed

    Berrazueta, J R; Poveda, J J; Puebla, F; Salas, E; Ochoteco, A; Gutiérrez, N

    1993-03-01

    A Holter monitorization study was performed in 100 voluntary university students (64 men and 36 women). The mean age was 23.6 years and organic heart disease was ruled out in all cases. Data were analysed in different subgroups including the practice of physical activity and subjects smokers or alcohol consumers. The maximum heart rate (HR) achieved during the wake period was 138.3 +/- 20.43 beat/m. Minimum daytime heart rate was 61.42 +/- 10.32 beat/m and it was below 60 beat/m in 41 subjects. During the nighttime period, the maximum heart rate achieved by the group was 89.34 +/- 11.31 beat/m. Minimum nighttime heart rate was 45.82 +/- 6.35 beat/m. Maximum heart rate in men was 134.3 +/- 21.35 beat/m, while in women was 145.42 +/- 16.36 beat/m. Eighty students presented one or more arrhythmias, among them 28 women and 52 men (p = NS): 92% in sportsmen and women groups as compared with 79% in the non sports practicers, 90% of alcohol consumers and 82% between subjects who smoked and drank, compared with 63% in the non drinkers (p < 0.006). 48% of the subjects presented one or more supraventricular arrhythmias during the daytime or during the nighttime (p = NS). Ventricular rhythm disturbances were found in 20 subjects. There was only one case who had a non sustained ventricular tachycardia of 4 complexes. These disturbances were not increased by practising sport nor by toxic habits. In 15 cases we found sinoatrial block, with a male predominance. Five subjects presented some type of atrioventricular block, 4 of which were alcohol and tobacco consumers.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Comparing 14-day adhesive patch with 24-h Holter monitoring.

    PubMed

    Cheung, Christopher C; Kerr, Charles R; Krahn, Andrew D

    2014-05-01

    Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor and 14-day adhesive patch monitor (Zio Patch) simultaneously. The primary outcome was the detection of any one of six arrhythmias: supraventricular tachycardia, atrial fibrillation/flutter, pause >3 s, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/fibrillation. The adhesive patch monitor detected more arrhythmia events compared with the Holter monitor over the total wear time (96 vs. 61 events; p < 0.001), although the Holter monitor detected more events during the initial 24-h monitoring period (61 vs. 52 events; p = 0.013). Novel, single-lead, intermediate-duration, user-friendly adhesive patch monitoring devices, such as the Zio Patch, represent the changing face of ambulatory ECG monitoring. However, the loss of quality, automated rhythm analysis and inability to detect myocardial ischemia continue to remain important issues that will need to be addressed prior to the implementation of these new devices.

  18. Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy.

    PubMed

    Seegers, Joachim; Bergau, Leonard; Expósito, Pascal Muñoz; Bauer, Axel; Fischer, Thomas H; Lüthje, Lars; Hasenfuß, Gerd; Friede, Tim; Zabel, Markus

    2016-07-01

    In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holter variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holter for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 ± 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (≥1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks

  19. Oropharyngeal 24-Hour pH Monitoring in Children With Airway-Related Problems

    PubMed Central

    Mesallam, Tamer A.

    2016-01-01

    Objectives Diagnosis and clinical presentation of pediatric laryngopharyngeal reflux (LPR) is still controversial. The aims of this work were to study the possibility of performing 24-hour oropharyngeal pH monitoring for children in the outpatient clinic setup and to explore the results of this test in correlation to airway-related problems. Methods In this descriptive qualitative study, 26 children suffering from airway-related problems were included. Oropharyngeal 24-hour pH monitoring was performed for all subjects in the outpatient clinic setting. The distribution of airway diagnoses among the study group was studied versus the results of the pH monitoring. Results There were 16 males and 10 females participated in the study with a mean age of 6.88 (SD, ±5.77) years. Thirty-five percent of the patients were under the age of 3 years (range, 11 months to 3 years). Eight-five percent of the patients tolerated the pH probe insertion and completed 24-hour of pH recording. Laryngomalacia and subglottic stenosis (SGS) were more frequently reported in the positive LPR patients (77%). Conclusion Oropharyngeal 24-hour pH monitoring can be conducted for children in the outpatient setup even in young age children below 3 years old. Among the positive LPR group, SGS and laryngomalacia were the most commonly reported airway findings. PMID:27090271

  20. Continuous 24-hour intraocular pressure monitoring for glaucoma--time for a paradigm change.

    PubMed

    Mansouri, K; Weinreb, R

    2012-01-01

    Glaucoma is the main cause of irreversible blindness and intraocular pressure (IOP) is its only modifiable risk factor. The importance of robust lowering of IOP for prevention of glaucoma onset and progression is well established. Although IOP is a dynamic parameter with individual circadian rhythms, current management usually relies on single IOP measurements during regular clinic hours performed a few times a year. Recent technological advances have provided clinicians with tools for continuous IOP monitoring during a 24 hour period in an ambulatory setting. There are two approaches being investigated. The first is permanent IOP monitoring through an implantable sensor and the other is temporary monitoring through a contact lens sensor. In this article, we discuss the shortcomings of the current gold standard for tonometry (Goldmann Applanation Tonometry) and the current experience with the first commercially available continuous 24 hour IOP monitoring technology (SENSIMED Triggerfish®); a telemetric contact lens sensor produced by a Swiss start-up company (Sensimed AG, Lausanne, Switzerland). Recent studies suggest that 24 hour continuous monitoring of IOP can be integrated into clinical practice and have the potential to contribute to the reduction of glaucoma-related vision loss.

  1. Huge ST elevation and ventricular arrhythmias in vasospastic angina diagnosed by Holter monitoring.

    PubMed

    Mugnai, Giacomo; Marchese, Giuseppe; Fede, Alfredo; Vassanelli, Corrado

    2013-01-01

    We report a case of a 67year old man with a recent history of sporadic chest pain and palpitations. After a normal, maximal stress test he underwent 24-hours Holter monitoring that showed two short periods of huge ST segment elevation associated with non sustained ventricular tachycardia and chest pain, referable to coronary spasm. Coronary angiogram showed significant atherosclerotic stenosis in the right coronary artery treated by angioplasty and bare metal stent implantation. Holter monitoring is a non-invasive and low-cost examination that can give valuable informations; it should be reserved for selected patients when vasospastic angina is suspected.

  2. Ambulatory arterial stiffness index derived from 24-hour ambulatory blood pressure monitoring.

    PubMed

    Li, Yan; Wang, Ji-Guang; Dolan, Eamon; Gao, Ping-Jin; Guo, Hui-Feng; Nawrot, Tim; Stanton, Alice V; Zhu, Ding-Liang; O'Brien, Eoin; Staessen, Jan A

    2006-03-01

    We hypothesized that 1 minus the slope of diastolic on systolic pressure during 24-hour ambulatory monitoring (ambulatory arterial stiffness index [AASI]) might reflect arterial stiffness. We compared AASI with established measures of arterial stiffness and studied its distribution in Chinese and European populations. We used 90207 SpaceLabs monitors and the SphygmoCor device to measure AASI, central and peripheral pulse pressures, the central (CAIx) and peripheral (PAIx) systolic augmentation indexes, and aortic pulse wave velocity. In 166 volunteers, the correlation coefficient between AASI and pulse wave velocity was 0.51 (P<0.0001). In 348 randomly recruited Chinese subjects, AASI correlated (P<0.0001) with CAIx (r=0.48), PAIx (r=0.50), and central pulse pressure (r=0.50). AASI increased with age and mean arterial pressure but decreased with body height. Both before and after adjustment for arterial wave reflections by considering height and heart rate as covariates, AASI correlated more (P<0.0001) closely with CAIx and PAIx than 24-hour pulse pressure. Among normotensive subjects, the 95th percentile of AASI was 0.55 in Chinese and 0.57 in 1617 Europeans enrolled in the International Database on Ambulatory Blood Pressure Monitoring. The upper boundary of the 95% prediction interval of AASI in relation to age ranged from 0.53 at 20 years to 0.72 at 80 years. In conclusion, AASI is a new index of arterial stiffness that can be easily measured under ambulatory conditions. Pending additional validation in outcome studies, normal values of AASI are probably <0.50 and 0.70 in young and older subjects, respectively. PMID:16432048

  3. [Development of direct and indirect ambulatory 24-hour blood pressure monitoring].

    PubMed

    Krönig, B

    1991-01-01

    The direct ambulatory 24-hour blood-pressure monitoring has been applied in two ways. With the so called "Oxford-system", blood pressure is recorded via a cannula in the brachial artery which is connected to a perfusion unit that is worn around the neck, on the front of the chest, with a tape recorder carried in a pouch on the patient's belt. Using the micro-catheter blood-pressure telemetry recording is done in the same way, but transmission of the data to a stationary-receiving unit is managed by telemetry. The usage of the latter method is limited by the weight and complexity of the patient-sited equipment. Compared to the Oxford-system there is the advantage of continuously observing the patients blood-pressure "on-line" during the recording. The invasive character of both methods limits the application to special, scientific investigations. In recent years the indirect recording machines for 24-hour blood-pressure monitoring has been developed further. They are now accurate, easy to apply and simple to work out. Beside the auscultatory way of recording, with or without ECG-gating, the oscillometry recording machines have been improved. There should be automatically-operated intervals with recordings in day-time every 15-20 minutes and during the night every 30 minutes. The recorded data should be analysed by computer, calculating mean values with standard deviations in day-time and night-time separately. Further more, there should be a listing of reading-errors and probably corrected measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Electrodes for 24 hours pH monitoring--a comparative study.

    PubMed Central

    McLauchlan, G; Rawlings, J M; Lucas, M L; McCloy, R F; Crean, G P; McColl, K E

    1987-01-01

    Three pH electrodes in clinical use were examined--(1) antimony electrode with remote reference electrode (Synectics 0011), (2) glass electrode with remote reference electrode (Microelectrodes Inc. MI 506) and (3) combined glass electrode with integral reference electrode (Radiometer GK2801C). In vitro studies showed that both glass electrodes were similar and superior to the antimony electrode with respect to response time, drift, and sensitivity. The effect of the siting of the reference electrode on the recorded pH was examined in five human volunteers. The pH reading using a remote skin reference electrode was higher by a mean of 0.3 pH units (range 0.0-0.6) in the stomach, lower by 0.65 pH units (0.5-0.8) in the duodenum and lower by 0.3 pH units (0.0-0.6) in the oesophagus than that simultaneously obtained with an intraluminal reference electrode. Buccal reference electrodes gave similar readings to skin. Combined reference and glass pH electrodes are recommended for 24-hour ambulatory pH monitoring. Images Fig. 1 PMID:3666560

  5. Holter Monitoring and Loop Recorders: From Research to Clinical Practice

    PubMed Central

    Ambrosini, Francesco; Lombardi, Federico

    2016-01-01

    Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases.

  6. Holter Monitoring and Loop Recorders: From Research to Clinical Practice

    PubMed Central

    Ambrosini, Francesco; Lombardi, Federico

    2016-01-01

    Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases. PMID:27617093

  7. Holter Monitoring and Loop Recorders: From Research to Clinical Practice.

    PubMed

    Galli, Alessio; Ambrosini, Francesco; Lombardi, Federico

    2016-08-01

    Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases.

  8. Holter Monitoring and Loop Recorders: From Research to Clinical Practice.

    PubMed

    Galli, Alessio; Ambrosini, Francesco; Lombardi, Federico

    2016-08-01

    Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases. PMID:27617093

  9. The Use of Continuous Electrocardiographic Holter Monitoring in Pediatric Cardiology

    PubMed Central

    Begic, Zijo; Begic, Edin; Mesihovic-Dinarevic, Senka; Masic, Izet; Pesto, Senad; Halimic, Mirza; Kadic, Almira; Dobraca, Amra

    2016-01-01

    Objective: To show the place and role of continuous electrocardiographic twenty-four-hour ECG monitoring in daily clinical practice of pediatric cardiologists. Methods: According to protocol, 2753 patients underwent dynamic continuous ECG Holter monitoring (data collected from the “Register of ECG Holter monitoring” of Pediatric Clinic, UCC Sarajevo in period April 2003- April 2015). Results: There were 50,5% boys and 49,5% girls, aged from birth to 19 years (1,63% - neonates and infants, 2,6% - toddlers, 9,95% - preschool children, 35,5% - gradeschoolers and 50,3% children in puberty and adolescence). In 68,1% of patients Holter was performed for the first time. Indications for conducting Holter were: arrhythmias in 42,2% cases, precordial pain in 23,5%, suspicion of pre-excitation and/or pre-excitation in 10%, crisis of consciousness in 8%, uncorrected congenital/acquired heart defects in 4,2%, operated heart defects in 3,7%, hypertension in 3,1% cases, control of the pacemaker in 1,63% and other causes in 3,5% cases. Discharge diagnosis after ECG Holter monitoring were: insignificant arrhythmias in 47,1% cases, wandering pacemaker in 21,3%, pre-excitation in 16,2%, benign ventricular premature beats in 6,3%, atrioventricular block in 3%, sinus pause in 2.2% cases and other arrhythmias in 3,5%. In mentioned period 57 cases of Wolf Parkinson White syndrome were registered, in 4,5% of patients antiarrhythmic therapy was administered. Radiofrequent ablation was performed in 23 cases. Conclusion: The development of pediatric cardiac surgery has initiated development of pediatric arrhythmology as imperative segment of pediatric cardiology. Continuous ECG Holter monitoring has become irreplaceable method in everyday diagnostics and therapy of arrhythmias in children. PMID:27708487

  10. Analysis of 24-Hour Ambulatory Blood Pressure Monitoring in Children With Obstructive Sleep Apnea

    PubMed Central

    Kang, Kun-Tai; Chiu, Shuenn-Nan; Weng, Wen-Chin; Lee, Pei-Lin; Hsu, Wei-Chung

    2015-01-01

    Abstract In the present study, we aimed to verify associations between ambulatory blood pressure (ABP) and pediatric obstructive sleep apnea (OSA) in a hospital-based population. This was a cross-sectional observational study on children aged 4 to 16 years with OSA-related symptoms from a tertiary referral medical center. All children received overnight polysomnography and 24-hour recording of ABP. Severity of the disease was classified as primary snoring (apnea-hypopnea index, AHI <1), mild OSA (AHI 1–5), and moderate-to-severe OSA (AHI >5). For 195 children enrolled in this study (mean age, 7.8 ± 3.4 years; 69% boy), ABP increased as severity of OSA increased. During daytime, children with moderate-to-severe OSA had significantly higher systolic blood pressure (BP) (117.0 ± 12.7 vs 110.5 ± 9.3 mmHg), mean arterial pressure (MAP) (85.6 ± 8.1 vs 81.6 ± 6.8 mmHg), and diastolic BP load (12.0 ± 9.6 vs 8.4 ± 10.9 mmHg) compared with children with primary snoring. During nighttime, children with moderate-to-severe OSA had significantly higher systolic BP (108.6 ± 15.0 vs 100.0 ± 9.4 mmHg), MAP (75.9 ± 9.6 vs 71.1 ± 7.0 mmHg), systolic BP load (44.0 ± 32.6 vs 26.8 ± 24.5 mmHg), systolic BP index (0.5 ± 13.1 vs −6.8 ± 8.5 mmHg), and higher prevalence of systolic hypertension (47.6% vs 14.7 %) compared with children with primary snoring. Multiple linear regression analyses revealed an independent association between AHI and nighttime systolic BP and MAP after adjusting for adiposity variables. This large hospital-based study showed that children with moderate-to-severe OSA had a higher ABP compared with children who were primary snorers. As elevated BP in childhood predicts future cardiovascular risks, children with severe OSA should be treated properly to prevent further adverse cardiovascular outcomes. PMID:26448004

  11. Predictors of poor blood pressure control assessed by 24 hour monitoring in patients with type B acute aortic dissection

    PubMed Central

    Delsart, Pascal; Midulla, Marco; Sobocinski, Jonathan; Achere, Charles; Haulon, Stephan; Claisse, Gonzague; Mounier-Vehier, Claire

    2012-01-01

    The chronic management of post-acute aortic dissection (AD) of the descending aorta (Type B) is based on optimal control of blood pressure (BP), with a target BP < 135/80 mmHg. The aim of our study was to determine and verify effective blood pressure control with an objective measurement method and to identify predicting factors. Methods We collected data from 26 patients hospitalized in the acute phase of a Type B AD between 2006 and 2009. Two groups were defined according to 24 hour BP monitoring results at follow-up. Group 1 consisted of patients with a controlled BP (<130/80 mmHg), and Group 2 consisted of patients with an uncontrolled BP. Results Thirty four percent of patients showed an uncontrolled BP at checkup. Vascular history before AD (P = 0.06), high baseline BP trend (P = 0.01 for systolic and P = 0.08 for diastolic), and greater diameter of the descending aorta (P = 0.02) were associated with poor BP control. Conclusion Prognosis after AD is associated with BP control. Therefore, 24 hour BP monitoring can be made. PMID:22272072

  12. [Individual peculiarities of adaptation to long-term space flights: 24-hour heart rhythm monitoring

    NASA Technical Reports Server (NTRS)

    Baevskii, R. M.; Bogomolov, V. V.; Gol'dberger, A. L.; Nikulina, G. A.; Charl'z, D. B.; Goldberger, A. L. (Principal Investigator); Charles, J. B. (Principal Investigator)

    2000-01-01

    Presented are results of studying 24-hr variability of the cardiac rhythm which characterizes individual difference in reactions of two crew members to the same set of stresses during a 115-day MIR mission. Spacelab (USA) cardiorecorders were used. Data of monitoring revealed significantly different baseline health statuses of the cosmonauts. These functional differences were also observed in the mission. In one of the cosmonauts, the cardiac regulation changed over to a more economic functioning with the autonomous balance shifted towards enhanced sympathetic activity. After 2-3 months on mission he had almost recovered pre-launch level of regulation. In the other, the regulatory system was appreciably strained at the beginning of the mission as compared with preflight baseline. Later on, on flight months 2-3, this strain kept growing till a drastic depletion of the functional reserve. On return to Earth, this was manifested by a strong stress reaction with a sharp decline in power of high-frequency and grow in power of very low frequency components of the heart rhythm. The data suggest that adaptation to space flight and reactions in the readaptation period are dependent on initial health status of crew members, and functional reserve.

  13. Effect of ambulatory 24-hour esophageal pH monitoring on reflux-provoking activities.

    PubMed

    Fass, R; Hell, R; Sampliner, R E; Pulliam, G; Graver, E; Hartz, V; Johnson, C; Jaffe, P

    1999-11-01

    Ambulatory 24-hr esophageal pH monitoring is considered the gold standard for diagnosing gastroesophageal reflux disease (GERD). The current approach is to encourage patients to pursue their everyday activity in order to obtain near-physiological recordings. However, the effect of the test itself on reflux-provoking activities has never been evaluated. Thus, the aim of our study was to assess daily food consumption, habits, symptoms, sleep, and perceived experience of patients undergoing pH testing as compared to an off test (normal) day. Patients reported type and time spent in each activity pursued, food ingested and length of each meal, habits, frequency and severity of GERD and other related symptoms, sleep disturbances, side effects, and overall perceived experience during pH testing and four weeks later, during a normal day. Fifty-four patients enrolled. pH testing significantly reduced time spent being active, number of meals and cups of coffee consumed, and frequency of GERD symptoms. Almost half of the patients reported having dysphagia during the test. Most patients experienced side effects and stated that the test bothered them most of the time. In conclusion, pH testing has a significant effect on decreasing reflux-provoking activities-patients tend to assume a more sedentary lifestyle. This may influence the reliability of the test as a physiologic measure of acid reflux.

  14. Discussion of "Computational Electrocardiography: Revisiting Holter ECG Monitoring".

    PubMed

    Baumgartner, Christian; Caiani, Enrico G; Dickhaus, Hartmut; Kulikowski, Casimir A; Schiecke, Karin; van Bemmel, Jan H; Witte, Herbert

    2016-08-01

    This article is part of a For-Discussion-Section of Methods of Information in Medicine about the paper "Computational Electrocardiography: Revisiting Holter ECG Monitoring" written by Thomas M. Deserno and Nikolaus Marx. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the paper of Deserno and Marx. In subsequent issues the discussion can continue through letters to the editor.

  15. Prevalence of type 1 brugada electrocardiographic pattern evaluated by twelve-lead twenty-four-hour holter monitoring.

    PubMed

    Cerrato, Natascia; Giustetto, Carla; Gribaudo, Elena; Richiardi, Elena; Barbonaglia, Lorella; Scrocco, Chiara; Zema, Domenica; Gaita, Fiorenzo

    2015-01-01

    Patients with drug-induced type 1 Brugada electrocardiograms (BrECGs) are considered to have good prognosis. Spontaneous type 1 is, instead, considered a risk factor; however, it is probably underestimated because of the BrECG fluctuations. The aim of this study was to analyze, in a large population of patients with Br, the real prevalence of type 1 BrECG using 12-lead 24-hour Holter monitoring (12L-Holter) and its correlation with the time of the day. We recorded 303 12L-Holter in 251 patients. Seventy-five (30%) patients exhibited spontaneous type 1 BrECG at 12-lead ECG (group 1) and 176 (70%) had only drug-induced type 1 (group 2). Type 1 BrECG was defined as "persistent" (>85% of the recording), "intermittent" (<85%), or "absent." In group 1, 12% showed persistent type 1 at 12L-Holter, 57% intermittent type 1%, and 31% never had type 1; in group 2, none had persistent type 1, 20% had intermittent type 1%, and 80% never showed type 1. To evaluate the circadian fluctuations of BrECG, 4 periods in the day were considered. Type 1 BrECG was more frequent between 12-noon and 6 p.m. (52%, p <0.001). In conclusion, in patients with drug-induced type 1, spontaneous type 1 BrECG can be detected more frequently with 12L-Holter than with conventional follow-up with periodic ECGs and this has important implications in the risk stratification. 12L-Holter recording might avoid 20% of the pharmacological challenges with sodium channel blockers, which are not without risks, and should thus be considered as the first screening test, particularly in children or in presence of borderline diagnostic basal ECG.

  16. Ambulatory Holter monitoring in asymptomatic patients with DDD pacemakers – do we need ACC/AHA Guidelines revision?

    PubMed Central

    Klimczak, Artur; Wranicz, Jerzy Krzysztof

    2013-01-01

    Introduction We sought to determine the usefulness of ambulatory 24-hour Holter monitoring in detecting asymptomatic pacemaker (PM) malfunction episodes in patients with dual-chamber pacemakers whose pacing and sensing parameters were proper, as seen in routine post-implantation follow-ups. Material and methods Ambulatory 24-hour Holter recordings (HM) were performed in 100 patients with DDD pacemakers 1 day after the implantation. Only asymptomatic patients with proper pacing and sensing parameters (assessed on PM telemetry on the first day post-implantation) were enrolled in the study. The following parameters were assessed: failure to pace, failure to sense (both oversensing and undersensing episodes) as well as the percentage of all PM disturbances. Results Despite proper sensing and pacing parameters, HM revealed PM disturbances in 23 patients out of 100 (23%). Atrial undersensing episodes were found in 12 patients (p < 0.005) with totally 963 episodes and failure to capture in 1 patient (1%). T wave oversensing was the most common ventricular channel disorder (1316 episodes in 9 patients, p < 0.0005). Malfunction episodes occurred sporadically, leading to pauses of up to 1.6 s or temporary bradycardia, which were, nevertheless, not accompanied by clinical symptoms. No ventricular pacing disturbances were found. Conclusions Asymptomatic pacemaker dysfunction may be observed in nearly 25% of patients with proper DDD parameters after implantation. Thus, ambulatory HM during the early post-implantation period may be a useful tool to detect the need to reprogram PM parameters. PMID:24273562

  17. Prevalence of Masked Hypertension: a Population-Based Survey in a Large City by Using 24-Hour Ambulatory Blood Pressure Monitoring

    PubMed Central

    Kim, Sun-Woong; Choi, Eun-Hee; Kim, Ji-Hyun; Nah, Deuk-Young; Shin, Sung-Joon; Gu, Namyi

    2016-01-01

    Background and Objectives We estimated the prevalence of hypertension and hypertension subtypes in a large semi-urban city in Korea, using 24-hour ambulatory blood pressure monitoring (ABPM) in a randomly selected sample population. Subjects and Methods A random sample (aged 20-65 years) from a city with an adult population of approximately 600000 was selected by using a list-assisted random digit dialing method. The 24-hour ABPM and conventional blood pressure measurement (CBPM) of these individuals were obtained. Results Among the 496 participants, valid 24-hour ABPM and CBPM were obtained from 462 (93%) individuals. The estimated prevalence of hypertension in Goyang was 17.54% by CBPM and 32.70% by 24-hour ABPM (p<0.01). In the age stratified analysis, both CBPM and 24-hour ABPM showed increased prevalence of hypertension with age. The estimated prevalence of masked hypertension was 16.22% and that of white-coat hypertension was 1.08%. Men had a higher prevalence of masked hypertension than women (20.79% vs. 11.86%, p=0.0295). The estimated prevalence of masked hypertension was 17.5%, 20.58%, 24.34%, and 13.29% in the age categories of 30s, 40s, 50s, and 60s, respectively. The estimated prevalence of masked uncontrolled hypertension was 26.79% in patients with hypertension who were taking antihypertensive medications. Conclusion The estimated prevalence of hypertension by 24-hour ABPM was higher than that by CBPM, revealing high prevalence of masked hypertension. The high prevalence of masked hypertension supports the adoption of ABPM in the national population survey and clinical practice to improve public health and reduce health care costs. PMID:27721860

  18. Timing and duration of myocardial ischemia on Holter monitoring following percutaneous coronary intervention and their association with clinical outcomes (a PROTECT-TIMI 30 Substudy Analysis).

    PubMed

    Gibson, C Michael; Pride, Yuri B; Buros, Jacqueline L; Ciaglo, Lauren N; Morrow, David A; Scirica, Benjamin M; Stone, Peter H

    2009-07-01

    In patients with unstable angina, evidence of myocardial ischemia on Holter monitoring is associated with an adverse prognosis. However, the association of duration and timing of ischemia on Holter monitoring with outcomes after percutaneous coronary intervention (PCI) in patients with non-ST-segment elevation acute coronary syndromes (NSTEACSs) has not been systematically evaluated. PROTECT-TIMI 30 randomized 857 patients with NSTEACSs undergoing PCI to eptifibatide plus a heparin product or bivalirudin monotherapy. Patients underwent continuous Holter monitoring following PCI, and the association between ischemia and clinical outcomes was evaluated retrospectively. Forty-three patients (5.0%) had ischemia on Holter after PCI. Any ischemia was associated with a significant increase in the incidence of death or myocardial infarction (MI) within 48 hours (32.6% vs 6.1%, odds ratio 7.5, 95% confidence interval 3.70 to 15.10, p <0.001). In patients who developed ischemia, there was a 1.44-fold increase in the odds for death or MI for every 30 minutes of ischemia (95% confidence interval 1.12 to 1.84, p = 0.004). Duration of ischemic events was related to their timing, such that ischemic events that occurred within the first 4 hours after PCI (median duration 141 minutes, interquartile range 36 to 227.5) were significantly longer than events occurring 4 to 24 hours after PCI (median duration 32.8 minutes, interquartile range 17.5 to 118, p = 0.041). In conclusion, early ischemia after PCI for NSTEACS is of longer duration, and longer duration of ischemia recognized by Holter monitoring is associated with an increased incidence of death or MI. Holter monitoring may be a useful surrogate end point in clinical trials.

  19. [Holter monitoring of patients treated with cytostatic agents].

    PubMed

    Kozáková, M; Beńesová, E; Cieslar, P; Sálková, J

    1989-01-20

    After cytostatic treatment severe arrhythmias, the development of angina pectoris and even the development of acute myocardial infarction and sudden death were observed. Therefore we made in 42 patients with malignant haematological disease treated with cytostatics 96 Holter monitorings of the electrocardiographic signal. The monitoring was made during the administration of cytostatics as well as during the time interval between the administration of combinations of cytostatics. In both instances (during the administration and during the interval between administration) we recorded a surprisingly high, mean all-day as well as maximal, heart rate. In the group monitored during administration of chemotherapeutic drugs we observed 5-8 hours after administration of cytostatics serious ventricular arrhythmias [incl. ventricular tachycardia], denivelization of the ST segment, paroxysms of supraventricular tachycardia. In the group monitored during the interval between administration of cytostatics the sick-sinus syndrome was recorded, as well as a passive nodal rhythm, disorders of the intraventricular conduction. The described changes are explained by the release of vasoactive substances after administration of cytostatics, by a change of the transmembrane calcium transport leading to an increased excitability of the heart muscle and possibly to coronary spasms and direct irreversible damage of the conduction system.

  20. Effect of burden and origin sites of premature ventricular contractions on left ventricular function by 7-day Holter monitor.

    PubMed

    Xu, Wenhua; Li, Mingfang; Chen, Minglong; Yang, Bing; Wang, Daowu; Kong, Xiangqing; Chen, Hongwu; Ju, Weizhu; Gu, Kai; Cao, Kejiang; Liu, Hailei; Jiang, Qi; Shi, Jiaojiao; Cui, Yan; Wang, Hong

    2015-11-01

    Recent studies have shown that premature ventricular contractions (PVCs) could enlarge the heart, but its risk factors are incompletely understood as a single 24-hour recording cannot reflect the true PVC burden due to day-to-day variability. Our purpose was to investigate the effect of burden and origin sites on left ventricular (LV) function in patients with PVCs by 7-day Holter electrocardiography (ECG). From May 2012 to August 2013, 112 consecutive patients with PVCs were recruited from the authors' affiliated hospital. All patients received 2-dimensional transthoracic echocardiography, 12-lead routing ECG and 7-days Holter ECG. Serum N-terminal pro-brain natriuretic peptide (NT-proBNP) levels were measured. A total of 102 participants with PVCs were included in the final analysis. Origin of PVCs from the tricuspid annulus had the highest burden and NT-proBNP level. LV papillary muscle had a higher LV ejection fraction (EF) level and a lower LV end-systolic dimension (ESD) than other PVC foci (P<0.05). The high burden group had a higher LV end-diastolic dimension (EDD) and LVESD but lower LVEF than the other two groups (P<0.05). Female, older age, physical work, and history of PVCs had a significantly positive correlation with symptoms. Male, older age, physical work, and high burden were positive predictors of enlarged LVEDD, LVESD and higher serum NT-proBNP level, but lower LVEF. Seven-day dynamic ECG Holter monitor showed the true PVC burden on patients with PVCs. PVCs with a lower burden or origin from the LV papillary muscle and the fascicle were relatively benign, while PVCs with a higher burden or origin from the tricuspid annulus may lead to cardiac dysfunction.

  1. Self-Perception of Swallowing-Related Problems in Laryngopharyngeal Reflux Patients Diagnosed with 24-Hour Oropharyngeal pH Monitoring

    PubMed Central

    Mesallam, Tamer A.; Farahat, Mohamed

    2016-01-01

    Background and Objectives. Swallowing difficulty is considered one of the nonspecific symptoms that many patients with laryngopharyngeal reflux complain of. However, the relationship between laryngopharyngeal reflux and swallowing problems is not clear. The purpose of this work is to explore correlation between swallowing-related problems and laryngopharyngeal reflux (LPR) in a group of patients diagnosed with oropharyngeal pH monitoring and to study the effect of laryngopharyngeal reflux on the patients' self-perception of swallowing problems. Methods. 44 patients complaining of reflux-related problems were included in the study. Patients underwent 24-hour oropharyngeal pH monitoring and were divided into positive and negative LPR groups based on the pH monitoring results. All patient filled out the Dysphagia Handicap Index (DHI) and Reflux Symptom Index (RSI) questionnaires. Comparison was made between the positive and negative LPR groups regarding the results of the DHI and RSI ratings. Also, correlation between DHI scores, RSI scores, and pH monitoring results was studied. Results. Significant difference was reported between positive and negative LPR groups regarding DHI scores, RSI scores, and overall rating of swallowing difficulty. There was significant correlation demonstrated between DHI scores, RSI scores, and 24-hour oropharyngeal pH results. Conclusion. Laryngopharyngeal reflux appears to have a significant impact on patients' self-perception of swallowing problems as measured by DHI. PMID:26966689

  2. :Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: implications for patient follow-up.

    PubMed

    Dagres, Nikolaos; Kottkamp, Hans; Piorkowski, Christopher; Weis, Sebastian; Arya, Arash; Sommer, Philipp; Bode, Kerstin; Gerds-Li, Jin-Hong; Kremastinos, Dimitrios Th; Hindricks, Gerhard

    2010-03-18

    We investigated the influence of Holter duration on the detection of recurrences after ablation for atrial fibrillation (AF). Two-hundred-and-fifteen patients underwent a 7-day Holter ECG at 6 months after catheter ablation. We analyzed the number of patients who had a recurrence within the first 24, 48, 72 h etc. up to the total of 7 days. During the complete 7-day recording, 30% had a recurrence. All Holter durations ≤5 days would have detected significantly less patients with recurrence than the complete 7-day recording. A 24-hour Holter would have detected 59%, a 48-hour Holter 67% and a 72-hour Holter 80% of patients with recurrences, whereas a 4-day recording would have detected 91% of the recurrences that were detected with the complete 7-day recording. In conclusion, a Holter duration of less than 4 days misses a great portion of recurrences, whereas a 4-day recording might offer a reasonable compromise.

  3. Liquid-containing Refluxes and Acid Refluxes May Be Less Frequent in the Japanese Population Than in Other Populations: Normal Values of 24-hour Esophageal Impedance and pH Monitoring

    PubMed Central

    Kawamura, Osamu; Kohata, Yukie; Kawami, Noriyuki; Iida, Hiroshi; Kawada, Akiyo; Hosaka, Hiroko; Shimoyama, Yasuyuki; Kuribayashi, Shiko; Fujiwara, Yasuhiro; Iwakiri, Katsuhiko; Inamori, Masahiko; Kusano, Motoyasu; Hongo, Micho

    2016-01-01

    Background/Aims Twenty-four-hour esophageal impedance and pH monitoring allows detection of all types of reflux episodes and is considered the best technique for identifying gastroesophageal refluxes. However, normative data for the Japanese population are lacking. This multicenter study aimed to establish the normal range of 24-hour esophageal impedance and pH data both in the distal and the proximal esophagus in Japanese subjects. Methods Forty-two healthy volunteers (25 men and 17 women) with a mean ± standard deviation age of 33.3 ± 12.4 years (range: 22–72 years) underwent a combined 24-hour esophageal impedance and pH monitoring. According to the physical and pH properties, distal or proximal esophageal reflux events were categorized. Results Median 45 reflux events occurred in 24 hours, and the 95th percentile was 85 events. Unlike previous reports, liquid-containing reflux events are median 25/24 hours with the 95th percentile of 62/24 hours. Acidic reflux events were median 11/24 hours with the 95th percentile of 39/24 hours. Non-acidic gas reflux events were median 15/24 hours with the 95th percentile of 39/24 hours. Proximal reflux events accounted for 80% of the total reflux events and were mainly non-acidic gas refluxes. About 19% of liquid and mixed refluxes reached the proximal esophagus. Conclusions Unlike previous studies, liquid-containing and acidic reflux events may be less frequent in the Japanese population. Non-acidic gas reflux events may be frequent and a cause of frequent proximal reflux events. This study provides important normative data for 24-hour impedance and pH monitoring in both the distal and the proximal esophagus in the Japanese population. PMID:27247103

  4. Prognosis in medically stabilized unstable angina: Early Holter ST-segment monitoring compared with predischarge exercise thallium tomography

    SciTech Connect

    Marmur, J.D.; Freeman, M.R.; Langer, A.; Armstrong, P.W. )

    1990-10-15

    The objective of this study was to assess the relative value of invasive and noninvasive predictors of outcome in patients after unstable angina. Fifty-four patients with unstable angina who had 6-month follow-up after stabilization on medical therapy were evaluated. We prospectively compared 24-hour Holter ST-segment monitoring at admission, quantitative exercise thallium tomography, and cardiac catheterization 5 +/- 2 days after admission and analyzed their value for predicting a cardiac event in patients with unstable angina within 6 months. When patients with a favorable outcome (n = 40) were compared with patients with an unfavorable outcome (n = 11) no statistical difference was found in duration of ST shift of 1 mm or more on Holter monitoring (51 +/- 119 min compared with 37 +/- 43 min), exercise duration by the standard Bruce protocol (8.0 +/- 3.6 min compared with 7.9 +/- 3.1 min), exercise-induced ST depression (0.6 +/- 0.9 mm compared with 1.0 +/- 1.0 mm), and contrast left ventricular ejection fraction (70% +/- 10% compared with 69% +/- 15%). Patients with a favorable outcome were distinguished from those with an unfavorable outcome by a higher maximum rate-pressure product (24 x 10(3) +/- 6 x 10(3) compared with 18 x 10(3) +/- 7 x 10(3), P = 0.0025), smaller size of the reversible scintigraphic perfusion defect expressed as a percentage of total myocardium imaged (6% +/- 11% compared with 17% +/- 18%, P = 0.05) and a smaller number of vessels with stenosis of 50% or more (1.1 +/- 1.2 compared with 2.1 +/- 1.0, P = 0.01). On multiple logistic regression analysis, a history of previous myocardial infarction was the most powerful predictor of outcome. In patients without myocardial infarction, reversible exercise thallium perfusion defect size was the only predictor.

  5. Holter monitoring for the screening of cardiac disease in diabetes mellitus: The non-invasive Holter monitoring observation of new cardiac events in diabetics study.

    PubMed

    Nakao, Yoko M; Ueshima, Kenji; Nohara, Ryuji; Mizunuma, Yoshimi; Segawa, Ikuo; Tanaka-Mizuno, Sachiko; Yasuno, Shinji; Nakao, Kazuwa; Hiramori, Katsuhiko; Kihara, Yasuki

    2015-11-01

    We investigated the usefulness of Holter monitoring to detect cardiac disease and predict future cardiovascular risk in asymptomatic diabetic patients. This is a multi-centre, prospective study in 406 asymptomatic diabetic patients. They were categorized into three groups based on findings of Holter monitoring. A total of 377 met inclusion criteria and were classified as low (n = 172), moderate (n = 136) and high risk (n = 69). In total, 86 in moderate and 53 in high risk receive further evaluation. In total, 29 in moderate and 25 in high risk were diagnosed as cardiac disease and 12 required additional treatment, including coronary intervention. Over 1.8 years of mean follow-up, 11 (16.5 per 1000 person-years) experienced cardiovascular events. The cumulative incidence in moderate and high risk was higher than that in low risk (p = 0.029 and p = 0.014, respectively). Our study suggests that Holter monitoring may be a useful screening tool to detect cardiac disease and predict future cardiovascular risk in asymptomatic diabetic patients.

  6. Detection of atrial fibrillation with concurrent holter monitoring and continuous cardiac telemetry following ischemic stroke and transient ischemic attack.

    PubMed

    Lazzaro, Marc A; Krishnan, Kousik; Prabhakaran, Shyam

    2012-02-01

    Atrial fibrillation (AF) is a major risk factor for recurrent ischemic stroke. We aimed to compare the detection rate of AF using continuous cardiac telemetry (CCT) versus Holter monitoring in hospitalized patients with ischemic stroke or transient ischemic attack (TIA). Between June 2007 and December 2008, 133 patients were admitted to an academic institution for ischemic stroke or TIA and underwent concurrent inpatient CCT and Holter monitoring. Rates of AF detection by CCT and Holter monitoring were compared using the McNemar paired proportion test. Among the 133 patients, 8 (6.0%) were diagnosed with new-onset AF. On average, Holter monitoring was performed for 29.8 hours, and CCT was performed for 73.6 hours. The overall rate of AF detection was higher for Holter monitoring compared with CCT (6.0%; 95% confidence interval [CI], 2.9-11.6 vs 0; 95% CI, 0-3.4; P = .008). Holter detection of AF was even higher in specific subgroups (those with an embolic infarct pattern, those age >65 years, and those with coronary artery disease). Holter monitoring detected AF in 6% of hospitalized ischemic stroke and TIA patients, with higher proportions in high-risk subgroups. Compared with CCT, Holter monitoring is significantly more likely to detect arrhythmias.

  7. Gastroesophageal and pharyngeal reflux detection using impedance and 24-hour pH monitoring in asymptomatic subjects: defining the normal environment.

    PubMed

    Oelschlager, Brant K; Quiroga, Elina; Isch, John A; Cuenca-Abente, Federico

    2006-01-01

    Airway symptoms are often caused by aspiration of refluxed materials into the larynx. In this study we sought to define the frequency, character, and proximal extent of refluxed contents - including nonacid reflux-in normal subjects using intraluminal impedance to improve our understanding of the relationship between reflux and aspiration. Ten subjects, who had no symptoms of gastroesophageal reflux disease or airway disease, underwent impedance/pH monitoring with a catheter that allowed simultaneous esophageal and pharyngeal monitoring. Impedance detected 496 gastroesophageal reflux episodes in the 10 subjects during 240 hours of study. The majority, 399 (81% of the total) were acid reflux episodes (pH < 4). Ninety-seven were nonacid (pH > 4). Most reflux episodes (348 of 496) reached the mid esophagus (9 cm above lower esophageal sphincter). There were 51 reflux episodes that reached the pharynx (PR). Only 13 (25%) of PR were acidic (pH < 4), while 38 were nonacid. Twenty-six PR episodes were liquid and 25 were mixed (liquid and gas). The median number of PR episodes measured with impedance was 5 (0-10). In asymptomatic subjects, most episodes of gastroesophageal reflux are acidic and reach the midesophagus. Reflux into the PR appears to be more common than previously believed, and most of these episodes are not acidic. Thus, traditional 24-hour pH monitoring may underestimate the presence of pharyngeal reflux. The combination of impedance with pH monitoring markedly enhances our ability to accurately detect potential microaspiration.

  8. Holter registers and metabolic syndrome

    NASA Astrophysics Data System (ADS)

    Muñoz-Diosdado, A.; Ramírez-Hernández, L.; Aguilar-Molina, A. M.; Zamora-Justo, J. A.; Gutiérrez-Calleja, R. A.; Virgilio-González, C. D.

    2014-11-01

    There is a relationship between the state of the cardiovascular system and metabolic syndrome (MS). A way to diagnose the heart state of a person is to monitor the electrical activity of the heart using a 24 hours Holter monitor. Scanned ECG signal can be analyzed beat-by-beat by algorithms that separate normal of abnormal heartbeats. If the percentage of abnormal heartbeats is too high it could be argued that the patient has heart problems. We have algorithms that can not only identify the abnormal heartbeats, but they can also classify them, so we classified and counted abnormal heartbeats in patients with MS and subjects without MS. Most of our patients have large waist circumference, high triglycerides and high levels of LDL (high-density lipoprotein) cholesterol although some of them have high blood pressure. We enrolled adult patients with MS free of diabetes in a four month lifestyle intervention program including diet and physical aerobic exercise, and compared with healthy controls. We made an initial registration with a Holter, and 24 hours ECG signal is analyzed to identify and classify the different types of heartbeats. The patients then begin with diet or exercise (at least half an hour daily). Periodically Holter records were taken up and we describe the evolution in time of the number and type of abnormal heartbeats. Results show that the percentage of abnormal heartbeats decreases over time, in some cases the decline is very significant, and almost a reduction to half or less of abnormal heartbeats after several months since the patients changed their eating or physical activity habits.

  9. Twenty-eight day Holter monitoring is poorly tolerated and insensitive for paroxysmal atrial fibrillation detection in cryptogenic stroke.

    PubMed

    Tu, H T; Spence, S; Kalman, J M; Davis, S M

    2014-05-01

    This pilot study in a prospective cohort of 20 cryptogenic stroke patients showed that a significant proportion has paroxysmal atrial fibrillation undetected by 24-h Holter monitoring. However, longer monitoring with 28-day Holter was poorly tolerated and still insufficiently sensitive for paroxysmal atrial fibrillation detection. Further studies are urgently needed to elucidate the optimal timing, method and duration of cardiac rhythm monitoring following ischaemic stroke.

  10. Recommendations of the Brazilian Society of Cardiac Arrhythmias for Holter Monitoring Services

    PubMed Central

    Lorga Filho, Adalberto; Cintra, Fatima Dumas; Lorga, Adalberto; Grupi, Cesar José; Pinho, Claudio; Moreira, Dalmo Antonio Ribeiro; Sobral Filho, Dario C.; de Brito, Fabio Sandoli; Kruse, José Claudio Lupi; Neto, José Sobral

    2013-01-01

    Background There are innumerous indicators to assure the quality of a service. However, medical competence and the proper performance of a procedure determine its final quality. The Brazilian Society of Cardiac Arrhythmias recommends minimum parameters necessary to guarantee the excellence of ambulatory electrocardiographic monitoring services. Objective To recommend minimum medical competences and the information required to issue a Holter monitoring report. Methods This study was grounded in the concept of evidence-based medicine and, when evidence was not available, the opinion of a writing committee was used to formulate the recommendation. That committee consisted of professionals with experience on the difficulties of the method and management in providing services in that area. Results The professional responsible for the Holter monitoring analysis should know cardiovascular pathologies and have consistent formation on electrocardiography, including cardiac arrhythmias and their differential diagnoses. The report should be written in a clear and objective way. The minimum parameters that comprise a Holter report should include statistics of the exam, as well as quantification and analysis of the rhythm disorders observed during monitoring. Conclusion Ambulatory electrocardiographic monitoring should be performed by professionals knowledgeable about electrocardiographic analysis, whose report should comprise the minimum parameters mentioned in this document. PMID:24030077

  11. Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

    SciTech Connect

    Carbaugh, Eugene H.

    2008-10-01

    The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

  12. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    PubMed

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  13. Human prolactin - 24-hour pattern with increased release during sleep.

    NASA Technical Reports Server (NTRS)

    Sassin, J. F.; Weitzman, E. D.; Kapen, S.; Frantz, A. G.

    1972-01-01

    Human prolactin was measured in plasma by radioimmunoassay at 20-minute intervals for a 24-hour period in each of six normal adults, whose sleep-wake cycles were monitored polygraphically. A marked diurnal variation in plasma concentrations was demonstrated, with highest values during sleep. Periods of episodic release occurred throughout the 24 hours.

  14. Holter monitoring to detect silent atrial fibrillation in high-risk subjects: the Perugia General Practitioner Study.

    PubMed

    Salvatori, Valentina; Becattini, Cecilia; Laureti, Stefano; Baglioni, Gregorio; Germini, Fabrizio; Grilli, Piero; Guercini, Francesco; Filippucci, Esmeralda; Agnelli, Giancarlo

    2015-08-01

    Atrial fibrillation (AF) is diagnosed for the first time in about 5 % of patients admitted for acute ischemic stroke. Advanced aged and arterial hypertension are risk factors for AF. We evaluated the prevalence of silent AF in subjects with advanced age and systemic arterial hypertension. Subjects of both gender, aged 65 years or more with systemic arterial hypertension were randomly identified from the patient lists of the participating general practitioners in the Perugia area, in Italy. Study subjects underwent baseline 12-lead ECG and, if this did not show AF, 48-h Holter monitoring was performed. AF was known and confirmed by 12-lead ECG in 4 out of the 308 evaluated subjects (1.3 %). Baseline 12-lead ECG showed no cases of silent AF. Holter monitoring was performed in 300 subjects, mean age 70 ± 4. Twenty-six recordings were not evaluable for the presence of artifacts; therefore, 274 subjects were included in the analysis. Holter monitoring showed AF in 27 out of 274 subjects (10 %; 95 % confidence interval 6.4-13.5 %); AF was longer than 30 s in four of the subjects. In 56 additional subjects, Holter monitoring revealed excessive supraventricular ectopic activity (20 %; 95 % confidence interval 15.3-24.7 %). Holter monitoring was able to detect silent AF in about 10 % of subjects aged 65 or above with systemic arterial hypertension. The risk of stroke associated with screened silent AF should be carefully evaluated.

  15. 24-Hour Relativistic Bit Commitment

    NASA Astrophysics Data System (ADS)

    Verbanis, Ephanielle; Martin, Anthony; Houlmann, Raphaël; Boso, Gianluca; Bussières, Félix; Zbinden, Hugo

    2016-09-01

    Bit commitment is a fundamental cryptographic primitive in which a party wishes to commit a secret bit to another party. Perfect security between mistrustful parties is unfortunately impossible to achieve through the asynchronous exchange of classical and quantum messages. Perfect security can nonetheless be achieved if each party splits into two agents exchanging classical information at times and locations satisfying strict relativistic constraints. A relativistic multiround protocol to achieve this was previously proposed and used to implement a 2-millisecond commitment time. Much longer durations were initially thought to be insecure, but recent theoretical progress showed that this is not so. In this Letter, we report on the implementation of a 24-hour bit commitment solely based on timed high-speed optical communication and fast data processing, with all agents located within the city of Geneva. This duration is more than 6 orders of magnitude longer than before, and we argue that it could be extended to one year and allow much more flexibility on the locations of the agents. Our implementation offers a practical and viable solution for use in applications such as digital signatures, secure voting and honesty-preserving auctions.

  16. Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

    NASA Technical Reports Server (NTRS)

    Baevsky, R. M.; Bennett, B. S.; Bungo, M. W.; Charles, J. B.; Goldberger, A. L.; Nikulina, G. A.

    1997-01-01

    This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.

  17. An atypical case of vasospastic angina: demonstrating the usefulness of Holter monitoring.

    PubMed

    Sanjeeva, Naveen Chandra Ganiga; Shetty, Ranjan K; Agarwal, Sumit

    2015-08-25

    Prinzmetal variant angina or vasospastic angina is a clinical syndrome characterised by episodic chest pain and transient reversible ST segment changes in ECG. The aetiology and treatment of the condition are quite different compared to those of conventional coronary artery disease. The crux of the problem in variant angina patients remains the diagnosis, especially if coexisting coronary artery disease is present. Timely diagnosis not only helps relieve symptoms, it also prevents complications such as ventricular tachycardia. Conventional provocative tests are used for diagnosis of such conditions; they have varied sensitively and specificity, and are cumbersome to perform. We present a case of an elderly man who presented with recurrent episodes of breathlessness and chest pain, where Holter monitoring proved to be a better mode for diagnosing variant angina than more invasive provocative tests. In this report, we reemphasis the role of this simple non-invasive diagnostic mode for diagnosis of variant angina.

  18. 24-Hour Academic Libraries: Adjusting to Change

    ERIC Educational Resources Information Center

    Bowman, Adam C.

    2013-01-01

    The purpose of this study was to explore the adaptive measures that academic libraries perform when implementing and operating a 24-hour schedule. Five in-depth interviews were conducted with current managerial-level librarians at 24-hour academic libraries. The exploratory interviews revealed similar measures for security, budgeting, employee…

  19. [Informative value of programmed electric stimulation of the ventricles, 24-hour ECG monitoring and bicycle ergometry in the diagnosis of electric instability of the myocardium in various clinical variants of stenocardia].

    PubMed

    Makhotina, V N; Rimsha, E; Kaĭk, Iu

    1991-01-01

    The informative value of programmed ventricular pacing (PVP), Holter monitoring (HM), and bicycle ergometry (BEM) in the diagnosis of myocardial electric instability was assessed in various clinical types of angina pectoris. An examination was made of 20 patients with first exercise-induced angina (FEIA), 33 with progressive exercise-induced angina (PEIA), 17 with spontaneous angina (SA), 30 with stable exercise-induced angina (SEIA), and postinfarction angina. Myocardial electric instability was estimated from HM and BEM findings in patients with FEIA, SA, as well as in PEIA, SEIA in the presence of preserved myocardial contractility as evidenced by ventriculography. A clear-cut correlation was found between transient myocardial ischemia and the occurrence of high-grade ventricular arrhythmias for the patients from the above-mentioned groups. Lower myocardial contractility despite the nature of angina is an indication for PVP.

  20. Comparison of Population Iodine Estimates from 24-Hour Urine and Timed-Spot Urine Samples

    PubMed Central

    Cogswell, Mary E.; Swanson, Christine A.; Sullivan, Kevin M.; Chen, Te-Ching; Carriquiry, Alicia L.; Dodd, Kevin W.; Caldwell, Kathleen L.; Wang, Chia-Yih

    2014-01-01

    Background: Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr×predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Methods: Volunteers aged 18–39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland–Altman plots. Results: Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3–156.2 μg/L; I/Cr 103.6–114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7–163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5–187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Conclusions: Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr×predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and

  1. The 24-Hour Mathematical Modeling Challenge

    ERIC Educational Resources Information Center

    Galluzzo, Benjamin J.; Wendt, Theodore J.

    2015-01-01

    Across the mathematics curriculum there is a renewed emphasis on applications of mathematics and on mathematical modeling. Providing students with modeling experiences beyond the ordinary classroom setting remains a challenge, however. In this article, we describe the 24-hour Mathematical Modeling Challenge, an extracurricular event that exposes…

  2. The otolaryngologic manifestations of gastroesophageal reflux disease (GERD): a clinical investigation of 225 patients using ambulatory 24-hour pH monitoring and an experimental investigation of the role of acid and pepsin in the development of laryngeal injury.

    PubMed

    Koufman, J A

    1991-04-01

    Occult (silent) gastroesophageal reflux disease (GER, GERD) is believed to be an important etiologic factor in the development of many inflammatory and neoplastic disorders of the upper aerodigestive tract. In order ot test this hypothesis, a human study and an animal study were performed. The human study consisted primarily of applying a new diagnostic technique (double-probe pH monitoring) to a population of otolaryngology patients with GERD to determine the incidence of overt and occult GERD. The animal study consisted of experiments to evaluate the potential damaging effects of intermittent GER on the larynx. Two hundred twenty-five consecutive patients with otolaryngologic disorders having suspected GERD evaluated from 1985 through 1988 are reported. Ambulatory 24-hour intraesophageal pH monitoring was performed in 197; of those, 81% underwent double-probe pH monitoring, with the second pH probe being placed in the hypopharynx at the laryngeal inlet. Seventy percent of the patients also underwent barium esophagography with videofluoroscopy. The patient population was divided into seven diagnostic subgroups: carcinoma of the larynx (n = 31), laryngeal and tracheal stenosis (n = 33), reflux laryngitis (n = 61), globus pharyngeus (n = 27), dysphagia (n = 25), chronic cough (n = 30), and a group with miscellaneous disorders (n = 18). The most common symptoms were hoarseness (71%), cough (51%), globus (47%), and throat clearing (42%). Only 43% of the patients had gastrointestinal symptoms (heartburn or acid regurgitation). Thus, by traditional symptomatology, GER was occult or silent in the majority of the study population. Twenty-eight patients (12%) refused or could not tolerate pH monitoring. Of the patients undergoing diagnostic pH monitoring, 62% had abnormal esophageal pH studies, and 30% demonstrated reflux into the pharynx. The results of diagnostic pH monitoring for each of the subgroups were as follows (percentage with abnormal studies): carcinoma (71

  3. Effects of Verapamil SR and Atenolol on 24-Hour Blood Pressure and Heart Rate in Hypertension Patients with Coronary Artery Disease: An International Verapamil SR-Trandolapril Ambulatory Monitoring Substudy

    PubMed Central

    Denardo, Scott J.; Gong, Yan; Cooper-DeHoff, Rhonda M.; Farsang, Csaba; Keltai, Matyas; Szirmai, László; Messerli, Franz H.; Bavry, Anthony A.; Handberg, Eileen M.; Mancia, Giuseppe; Pepine, Carl J.

    2015-01-01

    Elevated nighttime blood pressure (BP) and heart rate (HR), increased BP and HR variability, and altered diurnal variations of BP and HR (nighttime dipping and morning surge) in patients with systemic hypertension are each associated with increased adverse cardiovascular events. However, there are no reports on the effect of hypertension treatment on these important hemodynamic parameters in the growing population of hypertensive patients with atherosclerotic coronary artery disease (CAD). This was a pre-specified subgroup analysis of the INternational VErapamil SR-Trandolapril STudy (INVEST), which involved 22,576 clinically stable patients aged ≥50 years with hypertension and CAD randomized to either verapamil SR- or atenolol-based hypertension treatment strategies. The subgroup consisted of 117 patients undergoing 24-hour ambulatory monitoring at baseline and after 1 year of treatment. Hourly systolic and diastolic BP (SBP and DBP) decreased after 1 year for both verapamil SR- and atenolol-based treatment strategies compared with baseline (P<0.0001). Atenolol also decreased hourly HR (P<0.0001). Both treatment strategies decreased SBP variability (weighted standard deviation: P = 0.012 and 0.021, respectively). Compared with verapamil SR, atenolol also increased the prevalence of BP and HR nighttime dipping among prior non-dippers (BP: OR = 3.37; 95% CI: 1.26 – 8.97; P = 0.015; HR: OR = 4.06; 95% CI: 1.35-12.17; P = 0.012) and blunted HR morning surge (+2.8 vs. +4.5 beats/min/hr; P = 0.019). Both verapamil SR- and especially atenolol-based strategies resulted in favorable changes in ambulatory monitoring parameters that have been previously associated with increased adverse cardiovascular events. Trial Registration Clinicaltrials.gov; NCT00133692 PMID:25835002

  4. Laparoscopic Colon Resections With Discharge Less Than 24 Hours

    PubMed Central

    Ganji, Maedeh; Alam, Shaan E.; Kar, Pran M.

    2013-01-01

    Background and Objectives: A short hospital stay is one of the main advantages of laparoscopic surgery. Previous studies have shown that after a multimodal fast-track process, the hospital length of stay can be shortened to between 2 and 5 days. The objective of this review is to show that the hospital length of stay can, in some cases, be reduced to <24 hours. Methods: This study retrospectively reviews a surgeon's experience with laparoscopic surgery over a 12-month period. Seven patients were discharged home within 24 hours after minimally invasive laparoscopic surgical treatment, following a modified fast-track protocol that was adopted for perioperative care. Results: Of the 7 patients, 4 received laparoscopic right hemicolectomy for malignant disease and 3 underwent sigmoid colectomies for recurrent diverticulitis. The mean hospital stay was 21 hours, 47 minutes; the mean volume of intraoperative fluid (lactated Ringer) was 1850 mL; the mean surgical blood loss was only 74.3 mL; the mean duration of surgery was 118 minutes; and the patients were ambulated and fed a liquid diet after recovery from anesthesia. The reviewed patients had functional gastrointestinal tracts and were agreeable to the timing of discharge. On the follow-up visit, they showed no adverse consequences such as bleeding, infection, or anastomotic leak. Conclusion: Laparoscopic colon surgery that incorporated multimodal perioperative care allowed patients to be discharged within the first 24 hours. Careful postoperative outpatient follow-up is important in monitoring complications such as anastomotic leak, which may not present until postoperative day 5. PMID:23925012

  5. [Study of the informative value of Holter ECG monitoring and exercise test in ventricular arrhythmia in patients with ischemic heart disease and a high degree of myocardial electric instability, based on the data of programmed electric stimulation of the heart ventricles].

    PubMed

    Kaĭn, Iu L; Makhotina, V N; Vaĭnu, M K; Malviste, M R; Kalde, Iu L

    1989-03-01

    A total of 118 individuals were investigated to assess the value of Holter's ECG monitoring and bicycle ergometry for the identification of coronary patients predisposed to dangerous arrhythmias. Programmed ventricular stimulation was carried out: 1, 2 and 3 electric stimuli from the apex and/or outflow pathway of the right ventricle were applied in the presence of a pacemaker operating at 100 and 140 imp/min rates. The analysis of 24-hour ECG records demonstrated a correlation between some parameters (number of different ventricular extrasystole configurations, presence of high-grade ventricular arrhythmias) and the magnitude of myocardial electric instability, as shown by electric stimulation. An emergence or essential increase in ectopic ventricular activity during bicycle ergometry is not a precursor of myocardial instability at programmed pacemaker stimulation. At the same time, the absence of ventricular arrhythmias in response to stress does not exclude high-grade myocardial instability, detectable at programmed pacemaker stimulation.

  6. The importance of utilizing 24-h Holter monitoring as a non-invasive method of predicting the mechanism of supraventricular tachycardia.

    PubMed

    Al Mehairi, M; Al Ghamdi, S A; Dagriri, K; Al Fagih, A

    2011-10-01

    Despite the emergence of advanced invasive technology in identifying the various types of arrhythmia mechanisms, 24-h ambulatory electrocardiogram monitoring as a non-invasive method remains an invaluable informative tool in delineating such mechanisms. Furthermore, one observational study has supported the utilization of 24-h Holter monitoring in exploring AV Node (AVN) characteristics sufficiently in correlation with invasive studies when limited to patients without Wolf Parkinson White syndrome showing a positive predictive value of 98% in their supraventricular tachycardia (SVT) assessment (Fukuda et al., 2005). We describe in this report suspected tachycardia initiation mechanism in three SVT cases based on 24-h Holter recordings. Premature atrial contraction with subsequent AVN fast pathway conduction block initiated the common type AVN re-entrant tachycardia (AVNRT). Dual AVN physiology was documented during the electrophysiological studies in all three cases and a definitive therapy was achieved by the AVN slow pathway modification.

  7. 24-hour esophageal pH-monitoring in children suspected of gastroesophageal reflux disease: Analysis of intraesophageal pH monitoring values recorded in distal and proximal channel at diagnosis

    PubMed Central

    Semeniuk, Janusz; Kaczmarski, Maciej

    2007-01-01

    AIM: To assess values of 24-h esophageal pH-monitoring parameters with dual-channel probe (distal and proximal channel) in children suspected of gastroesophageal reflux disease (GERD). METHODS: 264 children suspected of gastroesophageal reflux (GER) were enrolled in a study (mean age χ = 20.78 ± 17.23 mo). The outcomes of this study, immunoallerrgological tests and positive result of oral food challenge test with a potentially noxious nutrient, enabled to qualify children into particular study groups. RESULTS: 32 (12.1%) infants (group 1) had physiological GER diagnosed. Pathological acid GER was confirmed in 138 (52.3%) children. Primary GER was diagnosed in 76 (28.8%) children (group 2) and GER secondary to allergy to cow milk protein and/or other food (CMA/FA) in 62 (23.5%) children (group 3). 32 (12.1%) of them had CMA/FA (group 4-reference group), and in remaining 62 (23.5%) children neither GER nor CMA/FA was confirmed (group 5). Mean values of pH monitoring parameters measured in distal and proximal channel were analyzed in individual groups. This analysis showed statistically significant differentiation of mean values in the case of: number of episodes of acid GER, episodes of acid GER lasting > 5 min, duration of the longest episode of acid GER in both channels, acid GER index total and supine in proximal channel. Statistically significant differences of mean values among examined groups, especially between group 2 and 3 in the case of total acid GER index (only distal channel) were confirmed. CONCLUSION: 24-h esophageal pH monitoring confirmed pathological acid GER in 52.3% of children with typical and atypical symptoms of GERD. The similar pH-monitoring values obtained in group 2 and 3 confirm the necessity of implementation of differential diagnosis for primary vs secondary cause of GER. PMID:17876877

  8. A Comparison of Atrial Fibrillation Monitoring Strategies After Cryptogenic Stroke (from the Cryptogenic Stroke and Underlying AF Trial).

    PubMed

    Choe, William C; Passman, Rod S; Brachmann, Johannes; Morillo, Carlos A; Sanna, Tommaso; Bernstein, Richard A; Di Lazzaro, Vincenzo; Diener, Hans-Christoph; Rymer, Marilyn M; Beckers, Frank; Koehler, Jodi; Ziegler, Paul D

    2015-09-15

    Ischemic stroke cause remains undetermined in 30% of cases, leading to a diagnosis of cryptogenic stroke. Paroxysmal atrial fibrillation (AF) is a major cause of ischemic stroke but may go undetected with short periods of ECG monitoring. The Cryptogenic Stroke and Underlying Atrial Fibrillation trial (CRYSTAL AF) demonstrated that long-term electrocardiographic monitoring with insertable cardiac monitors (ICM) is superior to conventional follow-up in detecting AF in the population with cryptogenic stroke. We evaluated the sensitivity and negative predictive value (NPV) of various external monitoring techniques within a cryptogenic stroke cohort. Simulated intermittent monitoring strategies were compared to continuous rhythm monitoring in 168 ICM patients of the CRYSTAL AF trial. Short-term monitoring included a single 24-hour, 48-hour, and 7-day Holter and 21-day and 30-day event recorders. Periodic monitoring consisted of quarterly monitoring through 24-hour, 48-hour, and 7-day Holters and monthly 24-hour Holters. For a single monitoring period, the sensitivity for AF diagnosis was lowest with a 24-hour Holter (1.3%) and highest with a 30-day event recorder (22.8%). The NPV ranged from 82.3% to 85.6% for all single external monitoring strategies. Quarterly monitoring with 24-hour Holters had a sensitivity of 3.1%, whereas quarterly 7-day monitors increased the sensitivity to 20.8%. The NPVs for repetitive periodic monitoring strategies were similar at 82.6% to 85.3%. Long-term continuous monitoring was superior in detecting AF compared to all intermittent monitoring strategies evaluated (p <0.001). Long-term continuous electrocardiographic monitoring with ICMs is significantly more effective than any of the simulated intermittent monitoring strategies for identifying AF in patients with previous cryptogenic stroke. PMID:26183793

  9. Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor

    PubMed Central

    Liu, John H. K.; Mansouri, Kaweh; Weinreb, Robert N.

    2015-01-01

    Purpose To compare estimates of 24-hour intraocular pressure (IOP) peak timing and variation obtained using a contact lens sensor (CLS) and using a pneumatonometer. Methods Laboratory data collected from 30 healthy volunteers (ages, 20-66 years) in a randomized, controlled clinical trial were analyzed. Participants were housed for 24 hours in a sleep laboratory. One randomly selected right or left eye was fitted with a CLS that monitored circumferential curvature in the corneoscleral region related to the change of IOP. Electronic output signals of 30 seconds were averaged and recorded every 5 minutes. In the contralateral eye, habitual IOP measurements were taken using a pneumatonometer once every two hours. Simulated 24-hour rhythms in both eyes were determined by cosinor fitting. Simulated peak timings (acrophases) and simulated data variations (amplitudes) were compared between the paired eyes. Results Bilateral change patterns of average 24-hour data for the group were in parallel. The simulated peak timing in the CLS fitted eye occurred at 4:44 AM ± 210 min (mean ± SD) and the IOP peak timing in the contralateral eye at 4:11 AM ± 120 min (P=0.256, Wilcoxon signed-rank test). There was no significant correlation between the simulated data variations in the paired eyes (P=0.820, linear regression). Conclusions The 24-hour CLS data showed a simulated peak timing close to the 24-hour IOP peak timing obtained using the pneumatonometer. However, the simulated variations of 24-hour data in the paired eyes were not correlated. Estimated 24-hour IOP rhythms using the two devices should not be considered interchangeable. PMID:26076472

  10. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  11. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  12. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  13. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  14. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  15. 24-hour central blood pressure and intermediate cardiovascular phenotypes in untreated subjects

    PubMed Central

    Bednarek, Agnieszka; Jankowski, Piotr; Olszanecka, Agnieszka; Windak, Adam; Kawecka-Jaszcz, Kalina; Czarnecka, Danuta

    2014-01-01

    Background: Recently, 24-hour monitoring of central systolic blood pressure (SBP) has become available. However, the relation between end-organ damage and the 24-hour central SBP profile and variability has not so far been analyzed. Therefore, the aim of this cross-sectional study was to evaluate the relation between 24-hour central SBP, 24-hour central SBP profile as well as central SBP short-term variability and parameters of cardiac and vascular intermediate phenotypes. Methods: The study group consisted of 50 patients with newly diagnosed, untreated hypertension (age 40.4 ± 11.5 years, 35 men) and 50 normotensive subjects (age 38.3 ± 12.0 years, 35 men). Applanation tonometry of the radial artery and the “n-point forward moving average” method were used to determine 24-hour central SBP. Each study participant underwent echocardiography and carotid ultrasonography. Results: 24-hour, daytime, and nighttime central SBP was related to left ventricle end-diastole diameter (p < 0.05), left ventricular mass index (p < 0.001), relative wall thickness (p < 0.05), E/E’ ratio (p < 0.01), and left atrium volume (p < 0.01). The nocturnal central SBP fall was not related to any of the mentioned parameters, whereas parameters of short-term variability were related to IMT in hypertensives only (p < 0.05). Conclusions: The present study showed that 24-hour central SBP is related to intermediate cardiac phenotypes as assessed by echocardiography whereas short-term central SBP variability is mainly related to vascular phenotype as determined by IMT. PMID:25628959

  16. Incidence and Predictors of New-Onset Atrial Fibrillation in Septic Shock Patients in a Medical ICU: Data from 7-Day Holter ECG Monitoring

    PubMed Central

    Guenancia, Charles; Binquet, Christine; Laurent, Gabriel; Vinault, Sandrine; Bruyère, Rémi; Prin, Sébastien; Pavon, Arnaud; Charles, Pierre-Emmanuel; Quenot, Jean-Pierre

    2015-01-01

    Purpose We investigated incidence, risk factors for new-onset atrial fibrillation (NAF), and prognostic impact during septic shock in medical Intensive Care Unit (ICU) patients. Methods Prospective, observational study in a university hospital. Consecutive patients from 03/2011 to 05/2013 with septic shock were eligible. Exclusion criteria were age <18 years, history of AF, transfer with prior septic shock. Included patients were equipped with long-duration (7 days) Holter ECG monitoring. NAF was defined as an AF episode lasting >30 seconds. Patient characteristics, infection criteria, cardiovascular parameters, severity of illness, support therapies were recorded. Results Among 66 patients, 29(44%) developed NAF; 10 (34%) would not have been diagnosed without Holter ECG monitoring. NAF patients were older, with more markers of heart failure (troponin and NT-pro-BNP), lower left ventricular ejection fraction (LVEF), longer QRS duration and more nonsustained supra ventricular arrhythmias (<30s) on day 1 than patients who maintained sinus rhythm. By multivariate analysis, age (OR: 1.06; p = 0.01) and LVEF<45% (OR: 13.01, p = 0.03) were associated with NAF. NAF did not predict 28 or 90 day mortality. Conclusions NAF is common, especially in older patients, and is associated with low ejection fraction. We did not find NAF to be independently associated with higher mortality. PMID:25965915

  17. Preparation and results of a 24-hour orbital flight.

    PubMed

    Titov, G S

    1963-01-01

    The space age presents man with unprecedented opportunities for discovery and for cooperative endeavors to benefit all mankind. My flight of August 6-7, 1961 was conducted for the purpose of determining whether man can stay and work effectively and whether all systems of the spaceship can operate successfully during a period of 24 hours in space. The flight of Vostok II represents an experimental step in a logical sequence which included the first earth orbiting flight of USSR citizen Yuri A. Gagarin. Preparation for the flight included the study of theoretical and applied subjects, testing in various kinds of apparatus which provide acceleration, heat and isolation experience, brief airborne weightless flights and parachute landings, in addition to extensive training in a real spacecraft having simulators for normal and emergency contingencies of space flight. The actual flight was therefore carried out with a sense of confidence and familiarity and with continuous close radio contact with ground centers from whom my fellow cosmonauts served as spokesmen. Sequential boosters totaling 600 000 kg thrust placed the 4731 kg spaceship into a perfect orbit varying in altitude from 178-246 km in a plane 64 degrees 58' inclined to the equator. The spaceship made 17 orbits around the earth landing 25 hours, 18 minutes after take-off. The cabin had full atmospheric pressure and a comfortable habitability which could be extended for 10 days. I was able to maneuver the spaceship and perform many other control functions, make observations and take pictures of the earth and its cloud cover, eat meals and sleep all with good efficiency. I experienced mild symptoms suggestive of seasickness which were aggravated by head turning, ameliorated by sleep and entirely relieved by resumption of g-loading during descent. Altogether analyses of the physical and structural performance of the spaceship and the continuously monitored physiological responses of the pilot indicate that all

  18. Using the net benefit regression framework to construct cost-effectiveness acceptability curves: an example using data from a trial of external loop recorders versus Holter monitoring for ambulatory monitoring of "community acquired" syncope

    PubMed Central

    Hoch, Jeffrey S; Rockx, Marie Antoinette; Krahn, Andrew D

    2006-01-01

    Background Cost-effectiveness acceptability curves (CEACs) describe the probability that a new treatment or intervention is cost-effective. The net benefit regression framework (NBRF) allows cost-effectiveness analysis to be done in a simple regression framework. The objective of the paper is to illustrate how net benefit regression can be used to construct a CEAC. Methods One hundred patients referred for ambulatory monitoring with syncope or presyncope were randomized to a one-month external loop recorder (n = 49) or 48-hour Holter monitor (n = 51). The primary endpoint was symptom-rhythm correlation during monitoring. Direct costs were calculated based on the 2003 Ontario Health Insurance Plan (OHIP) fee schedule combined with hospital case costing of labour, materials, service and overhead costs for diagnostic testing and related equipment. Results In the loop recorder group, 63.27% of patients (31/49) had symptom recurrence and successful activation, compared to 23.53% in the Holter group (12/51). The cost in US dollars for loop recording was $648.50 and $212.92 for Holter monitoring. The incremental cost-effectiveness ratio (ICER) of the loop recorder was $1,096 per extra successful diagnosis. The probability that the loop recorder was cost-effective compared to the Holter monitor was estimated using net benefit regression and plotted on a CEAC. In a sensitivity analysis, bootstrapping was used to examine the effect of distributional assumptions. Conclusion The NBRF is straightforward to use and interpret. The resulting uncertainty surrounding the regression coefficient relates to the CEAC. When the link from the regression's p-value to the probability of cost-effectiveness is tentative, bootstrapping may be used. PMID:16756680

  19. The 24 Hours before Hospitalization: Factors Related to Suicide Attempting.

    ERIC Educational Resources Information Center

    Chiles, John A.; And Others

    1986-01-01

    Psychiatric inpatients (N=59) were interviewd concerning psychological and environmental events that occurred in the 24 hours prior to their hospitalization. Suicide attempters were more likely to have used alcohol or marijuana and less likely to have contacted a health care professional than suicide ideators, even when past history of suicide…

  20. Effect of daily oral omeprazole on 24 hour intragastric acidity.

    PubMed Central

    Walt, R P; Gomes, M D; Wood, E C; Logan, L H; Pounder, R E

    1983-01-01

    Twenty four hour intragastric acidity was measured in nine patients with duodenal ulcer before and after one week of treatment with oral omeprazole 30 mg daily, a drug that inhibits gastric secretion by inhibition of parietal cell H+K+ adenosinetriphosphatase (ATPase). Omeprazole virtually eliminated intragastric acidity in all patients: the median 24 hour intragastric pH rose from 1.4 to 5.3 and the mean hourly hydrogen ion activity fell from 38.50 to 1.95 mmol(mEq)/1 (p less than 0.001). This inhibition of 24 hour intragastric acidity is more profound than that previously reported with either cimetidine 1 g daily or ranitidine 300 mg daily. PMID:6407676

  1. Holter ECG for pacemaker/defibrillator carriers: what is its role in the era of remote monitoring?

    PubMed

    Diemberger, Igor; Gardini, Beatrice; Martignani, Cristian; Ziacchi, Matteo; Corzani, Alessandro; Biffi, Mauro; Boriani, Giuseppe

    2015-08-01

    Nowadays several diagnostic tools are available to investigate cardiovascular symptoms like palpitations, dizziness and syncope: ECG Holter (or ambulatory ECG, AECG), external and implantable event/loop recorders. Despite this technological burden, many diagnoses are still missed. In the meantime, we are facing an increasing use of implantable devices for cardiac pacing/defibrillation (CIED), which have rapidly evolved from simple pacing/shock boxes to devices including several diagnostic features. However, these functions are not adequately exploited in current clinical practice and several redundant diagnostic tests, like AECG, are still prescribed to CIED carriers, leading to an increase of costs and a delay in final diagnosis. This review is aimed at identifying the current role of AECG in CIED carriers in view of this technological improvement. First, we will briefly present the indications for AECG according to current guidelines. We will then provide a direct comparison of the different diagnostic features provided by AECG (and event/loop recorders) versus automatic diagnostic CIED to highlight the respective pros and cons. This will serve to carefully discuss these indications in view of the results of recent studies on CIED carriers, highlighting the need for proper implantation and follow-up. Eventually, we will provide useful hints to properly analyse AECG in CIED carriers, considering the different behaviours according to the implemented algorithms. We will conclude by suggesting updated indications for AECG.

  2. Demonstration that thiazole-orange-positive platelets in the dog are less than 24 hours old.

    PubMed

    Dale, G L; Friese, P; Hynes, L A; Burstein, S A

    1995-04-01

    Approximately 6% of dog platelets are positive for staining with thiazole orange, a dye frequently used to stain ribonucleic acid. In this report, thiazole-orange positivity is shown to mark platelets that are less than 24 hours old. Dog platelets were derivatized in vivo with N-hydroxysuccinimido biotin such that greater than 95% of all platelets were biotinylated. Newly synthesized, nonbiotinylated platelets were then monitored by flow cytometry for their ability to bind thiazole orange. After biotinylation, the percentage of biotin-negative, thiazole-orange-positive platelets increased gradually from 0.72% at 30 minutes to 5.44% at 24 hours. These data indicate that thiazole-orange staining does label newly synthesized platelets.

  3. Multiprocessor system for Holter tape analysis (ECG)

    SciTech Connect

    Feldman, C.L.; Hubelbank, M.; Valvo, V.; Lane, B.

    1983-01-01

    Although techniques for recording and analyzing longterm ambulatory ECGS have been in existence for more than 20 years, the clinical usefulness and frequency of application of the technique continue to grow at an extraordinary rate. To meet the need for faster, more efficient processing of Holter tapes and the growing requirement that the analysis of the tape be quantitatively accurate, a new Holter analysis system has been developed. This system is built around two LSI11 microprocessors and a special purpose byte processor which incorporates an AMD 2903 bit slice chip. It includes 30 MB of mass storage and an impact printer with alphanumeric and graphic capabilities. In a test which included 55 separate readings of 34 12- or 24-hour tapes, correlations with hand counts of vpbs was greater than .99. The system processes either cassette or reel-to-reel tapes at 120* with simultaneous print/process capabilities, has a variety of user interactive displays to assure continuous operator validation, is remarkably nonfatiguing to operate, and automatically produces reports with tables, graphs, and sample ECG strips. 8 references.

  4. [ANMCO/AIIC/SIT Consensus document: Definition, precision and appropriateness of the electrocardiographic signal of electrocardiographic recorders, ergometry systems, Holter systems, telemetry and bedside monitors].

    PubMed

    Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Gensini, Gian Franco

    2016-06-01

    The ECG signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests and systems for telemetry and bedside monitoring of vital parameters, useful to rhythm and ST-segment analysis and ECG screening of cardiac electrical sudden death predictors. A precise ECG diagnosis is based upon a correct recording, elaboration and presentation of the signal. Several sources of artifacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depends upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high quality ECG signal are therefore of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to offer a scientific reference for the choice of systems able to offer a high quality ECG signal acquisition, processing and presentation suitable for clinical use. PMID:27311085

  5. [ANMCO/AIIC/SIT Consensus document: Definition, precision and appropriateness of the electrocardiographic signal of electrocardiographic recorders, ergometry systems, Holter systems, telemetry and bedside monitors].

    PubMed

    Gulizia, Michele Massimo; Casolo, Giancarlo; Zuin, Guerrino; Morichelli, Loredana; Calcagnini, Giovanni; Ventimiglia, Vincenzo; Censi, Federica; Caldarola, Pasquale; Russo, Giancarmine; Leogrande, Lorenzo; Gensini, Gian Franco

    2016-06-01

    The ECG signal can be derived from different sources. These include systems for surface ECG, Holter monitoring, ergometric stress tests and systems for telemetry and bedside monitoring of vital parameters, useful to rhythm and ST-segment analysis and ECG screening of cardiac electrical sudden death predictors. A precise ECG diagnosis is based upon a correct recording, elaboration and presentation of the signal. Several sources of artifacts and potential external causes may influence the quality of the original ECG waveforms. Other factors that may affect the quality of the information presented depends upon the technical solutions employed to improve the signal. The choice of the instrumentations and solutions used to offer a high quality ECG signal are therefore of paramount importance. Some requirements are reported in detail in scientific statements and recommendations. The aim of this consensus document is to offer a scientific reference for the choice of systems able to offer a high quality ECG signal acquisition, processing and presentation suitable for clinical use.

  6. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion

    PubMed Central

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-01-01

    Abstract Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286–4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the

  7. Managing sleep and wakefulness in a 24-hour world

    PubMed Central

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work–social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns. PMID:23957268

  8. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation.

    PubMed

    Taber, Michael J; Hartley, Geoffrey L; McGarr, Gregory W; Zaharieva, Dessi; Basset, Fabien A; Hynes, Zach; Haman, Francois; Pinet, Bernard M; DuCharme, Michel B; Cheung, Stephen S

    2016-01-01

    Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (T c) and cognitive test battery (CTB) performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature). Participants (recruited from those who have regular occupational exposure to cold) were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease T c after exposure and to eliminate the typical 0.5-1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance. PMID:27478839

  9. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation

    PubMed Central

    Hartley, Geoffrey L.; Zaharieva, Dessi; Basset, Fabien A.; Hynes, Zach

    2016-01-01

    Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (Tc) and cognitive test battery (CTB) performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature). Participants (recruited from those who have regular occupational exposure to cold) were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease Tc after exposure and to eliminate the typical 0.5–1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance. PMID:27478839

  10. [Necessity of a 24-hour system of blood transfusion testing].

    PubMed

    Kishimoto, Yuji

    2003-01-01

    The preventive effects of a 24-hour system of blood transfusion testing on mistyping of transfused blood was examined. Blood transfusion tests have been performed by blood transfusion technologists during working hours and by physicians at other times. In March 2000, we introduced a system in which technologists perform blood transfusion tests after working hours. Technologists of the Blood Transfusion Unit and Central Clinical Laboratory perform the test jointly, and column agglutination technology was introduced as the test method. A computer system setup exclusively for the testing was also introduced to perform computer cross-matching. Since transfusion error is likely to occur during emergency blood transfusion, a manual was established to prioritize safety. After introduction of the system, mistyping that may have been caused by inaccurate blood test results markedly decreased, confirming the usefulness of this system for prevention of mistyping. In addition, transfusion errors also decreased in wards and the improved system increased the safety of the entire medical care system. The frequency of mistyping was about 1% when physicians performed blood typing, showing the importance of clinical technologists for blood transfusion tests. PMID:12652691

  11. Managing sleep and wakefulness in a 24-hour world.

    PubMed

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work-social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns.

  12. Flexibility of working hours in the 24-hour society.

    PubMed

    Costa, G

    2006-01-01

    The 24-hour Society undergoes an ineluctable process towards a social organisation where time constraints are no more restricting human life. The borders between working and social times are no more fixed and rigidly determined, and the value of working time changes according to the different economic and social effects you may consider. Shift and night work, irregular and flexible working hours, together with new technologies, are the milestone of this epochal passage. What are the advantages and disadvantages for the individual, the companies, and the society? What is the cost/benefit ratio in terms of health and social well-being? Coping properly with this process means avoiding a passive acceptance of it with consequent maladjustments at both individual and social level, but adopting effective preventive and compensative strategies aimed at building up a more sustainable society. Flexible working times now appear to be one of the best ways to cope with the demands of the modern life, but there are different points of view about labour and temporal 'flexibility" between employers and employees. For the former it means a prompt adaptation to market demands and technological innovations; for the latter it is a way to improve working and social life, by decreasing work constraints and increasing control and autonomy. Although it can be easily speculated that individual-based 'flexibility" should improve health and well-being, and especially satisfaction, whereas company-based flexibility" might interfere negatively, the effective consequences on health and well-being have still to be analysed properly. PMID:17017360

  13. [To the centennial of Norman Holter (1914-1983)].

    PubMed

    Makarov, L M

    2015-01-01

    The article is devoted to the centennial of the founder of ambulatory ECG monitoring Norman Jeffrey Holter (1914-1983). It contains brief history of the scientist's family, and depiction of his own educational way from magister of chemistry and physics to specialist in nuclear research. His activity during World War II, research related to impact of nuclear tests on environment after the war is also described. The fact is stressed that N. Holter was organizer and first president of Society of Nuclear Medicine. But most prominent contribution of N. Holter was elaboration of the method of long-term ECG monitoring of freely active patients--the method which was later named Holter Monitoring (HM). The article also contains data of first clinical trials of HM systems and stresses contribution of Holter team-mates and colleagues (B. Del Mar, G. Kennedy, S. Stern and others) in their conduct. It shows technical and ideological evolution of HM systems from large apparatuses weighting 40 kg to modern portable devices capable of collecting, storing and processing huge amounts of information, transmitting it over internet to any distance. Nontriviality and serendipity of N. Holter's approach to obtaining novel unpredictable knowledge allowed him to realize his numerous talents and abilities.

  14. [To the centennial of Norman Holter (1914-1983)].

    PubMed

    Makarov, L M

    2015-01-01

    The article is devoted to the centennial of the founder of ambulatory ECG monitoring Norman Jeffrey Holter (1914-1983). It contains brief history of the scientist's family, and depiction of his own educational way from magister of chemistry and physics to specialist in nuclear research. His activity during World War II, research related to impact of nuclear tests on environment after the war is also described. The fact is stressed that N. Holter was organizer and first president of Society of Nuclear Medicine. But most prominent contribution of N. Holter was elaboration of the method of long-term ECG monitoring of freely active patients--the method which was later named Holter Monitoring (HM). The article also contains data of first clinical trials of HM systems and stresses contribution of Holter team-mates and colleagues (B. Del Mar, G. Kennedy, S. Stern and others) in their conduct. It shows technical and ideological evolution of HM systems from large apparatuses weighting 40 kg to modern portable devices capable of collecting, storing and processing huge amounts of information, transmitting it over internet to any distance. Nontriviality and serendipity of N. Holter's approach to obtaining novel unpredictable knowledge allowed him to realize his numerous talents and abilities. PMID:26050493

  15. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns

    PubMed Central

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  16. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers.

    PubMed

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m(2), had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab(®) device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens(®) algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for "24-hour", "awake", and "asleep" periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects.

  17. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns.

    PubMed

    Xu, Sarah C; Gauthier, Angela C; Liu, Ji

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  18. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers.

    PubMed

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m(2), had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab(®) device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens(®) algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for "24-hour", "awake", and "asleep" periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects. PMID:24812515

  19. [High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism].

    PubMed

    Rojo-Martinez, Esther; Sandín-Fuentes, María; Calleja-Sanz, Ana I; Cortijo-García, Elisa; García-Bermejo, Pablo; Ruiz-Piñero, Marina; Rubio-Sanz, Jerónimo; Arenillas-Lara, Juan F

    2013-09-16

    Introduccion. El holter implantable permite detectar fibrilacion auricular paroxistica (FAP) oculta en pacientes con ictus criptogenico, pero se desconoce que algoritmo de seleccion tiene un mayor rendimiento y la duracion optima de monitorizacion. Objetivo. Conocer la frecuencia y el tiempo hasta detectar la FAP mediante un holter implantable Reveal XT ® en pacientes con ictus criptogenico seleccionados por sospecha elevada de embolismo cerebral. Pacientes y metodos. Criterios de seleccion: ausencia de etiologia del ictus tras el estudio completo incluyendo un ecocardiograma transesofagico, monitorizacion ECG y holter de 24 horas, asi como confirmacion de oclusion aguda embolica de la arteria intracraneal por duplex transcraneal o bien alta sospecha de embolismo por caracteristicas de neuroimagen. Tras implantar el holter Reveal XT se formo a los pacientes para que emprendieran transmisiones todos los meses o ante sintomas. Se reviso la informacion online mensualmente y se realizaron visitas clinicas en las unidades de Neurologia y Cardiologia. Resultados. Se incluyeron 101 pacientes con ictus criptogenico y al menos un mes de seguimiento: edad media de 67 años, 54 mujeres (53,5%). Tiempo medio de seguimiento: 281 ± 212 dias. Se detecto FAP oculta en 34 pacientes (33,7%) y falsos positivos en 23 (22,8%). Mediana desde el implante hasta la deteccion de la arritmia: 102 dias (rango: 26-240 dias). En un 70% de los pacientes se registraron multiples episodios de FAP. El 75% de los eventos se detectaron durante los primeros seis meses de monitorizacion. Conclusiones. El algoritmo de seleccion de pacientes con ictus criptogenico segun sospecha de embolismo cerebral se asocio a una elevada frecuencia (33,7%) de FAP oculta con holter implantable. Uno de cada cuatro eventos sucedio tras los primeros seis meses de monitorizacion.

  20. Assessing the interaction of respiration and heart rate in heart failure and controls using ambulatory Holter recordings.

    PubMed

    Haigney, Mark; Zareba, Wojceich; La Rovere, Maria Teresa; Grasso, Ian; Mortara, David

    2014-01-01

    Breathing is a critical component of cardiopulmonary function, but few tools exist to evaluate respiration in ambulatory patients. Holter monitoring allows accurate diagnosis of a host of cardiac issues, and several investigators have demonstrated the ability to detect respiratory effort on the electrocardiogram. In this study we introduce a myogram signal derived from 12-lead, high frequency Holter as a means of detecting respiratory effort. Using the combined myogram and ECG signal, four novel variables were created: total number of Cheyne-Stokes episodes; the BWRatio, the ratio of power (above baseline) measured one second after peak-to-peak respiratory power, an assessment of the "shape" of the respiratory effort; DRR, the change in RR interval centering around peak inspiration; and minutes of synchronized breathing, a fixed ratio of heart beats to respiratory cycles. These variables were assessed in 24-hour recordings from three cohorts: healthy volunteers (n=33), heart failure subjects from the GISSI HF trial (n=383), and subjects receiving implantable defibrillators with severely depressed left ventricular function enrolled in the M2Risk trial (n=470). We observed a statistically significant 6-fold increase in the number of Cheyne-Stokes episodes (p=0.01 by ANOVA), decreases in BWRatio (p<0.001), as well as decrease in DRR in heart failure subjects; only minutes of synchronized breathing was not significantly decreased in heart failure. This study provides "proof of concept" that novel variables incorporating Holter-derived respiration can distinguish healthy subjects from heart failure. The utility of these variables for predicting heart failure, arrhythmia, and death risk in prospective studies needs to be assessed.

  1. [HOLTER TAKES CENTER STAGE INTO FINAL INDICATION OF CARDIAC STIMULATION].

    PubMed

    Gracía Barrera, Ma De Gracia

    2016-02-01

    The study was performed in order to obtain specific data confirming the influence in the diagnosis of many cardiac pathologies detected by Holter heart rate. Holter heart rate of 24 hours is an electronic device, of small size, which records and stores an electrocardiographic tracing two or three leads, while the patient activities of daily life. It leads us to conduct this study increased requests we've had in our hospital and the numerous reports that have helped in the diagnosis of our patients. We base the study with statistical data, therefore, produce two databases, one that reflects the total of studies conducted in 2013 and another with patients diagnosed with cardiac stimulation and need to refer to it. Crossing these two databases get third with patients referred for cardiac stimulation Holter heart rate realized. With these data we can say that, when this test is requested, it has a great influence on the final diagnosis (87%) and there is a high probability of finding significant findings, without forgetting the clinical and personal aspects of each patient.

  2. Low correlation between visit-to-visit variability and 24-hour variability of blood pressure

    PubMed Central

    Muntner, Paul; Shimbo, Daichi; Diaz, Keith M.; Newman, Jonathan; Sloan, Richard P.; Schwartz, Joseph E.

    2013-01-01

    Visit-to-visit variability (VVV) of clinic systolic blood pressure (SBP) has been associated with cardiovascular disease risk. Given the need for obtaining blood pressure (BP) at multiple visits to calculate VVV, substituting BP variability from ambulatory blood pressure monitoring (ABPM) may be a practical alternative. We assessed the correlation between VVV of BP and BP variability from ABPM using data from 146 untreated, mostly normotensive participants (mean age 47.9 years) in a substudy of the ongoing Masked Hypertension Study. VVV of SBP and diastolic blood pressure (DBP) was estimated by the standard deviation (SDvvv) and average real variability (ARVvvv) from 6 study visits over a median of 216 days. ABPM data were used to calculate the day-night SD (SDdn) and the ARV of SBP and DBP over 24 hours (ARV24). For SBP, the mean SDvvv and SDdn were 6.3 (SD=2.5) and 8.8 (SD=1.8) mmHg, respectively, and mean ARVvvv and ARV24 were 7.2 (SD=3.2) and 8.4 (SD=2.1) mmHg, respectively. The Spearman correlation coefficient between SDvvv and SDdn of SBP was rs=0.25 and between ARVvvv and ARV24 was rs=0.17. Participants in the highest quartile of SDdn of SBP were 1.66 (95% CI: 0.93 – 2.75) times more likely to be in the highest quartile of SDvvv of SBP. The observed-to-expected ratio between the highest quartiles of ARVvvv and ARV24 of SBP was 0.89 (95% CI: 0.41 – 1.69). The correlations for SDvvv and SDdn and ARVvvv and ARV24 of DBP were minimal. These data suggest VVV and 24-hour variability are weakly correlated and not interchangeable. PMID:23784506

  3. A 24-hour remote surveillance system for terrestrial wildlife studies

    USGS Publications Warehouse

    Sykes, P.W.; Ryman, W.E.; Kepler, C.B.; Hardy, J.W.

    1995-01-01

    The configuration, components, specifications and costs of a state-of-the-art closed-circuit television system with wide application for wildlife research and management are described. The principal system components consist of color CCTV camera with zoom lens, pan/tilt system, infrared illuminator, heavy duty tripod, coaxial cable, coaxitron system, half-duplex equalizing video/control amplifier, timelapse video cassette recorder, color video monitor, VHS video cassettes, portable generator, fuel tank and power cable. This system was developed and used in a study of Mississippi sandhiIl Crane (Grus canadensis pratensis) behaviors during incubation, hatching and fledging. The main advantages of the system are minimal downtime where a complete record of every event, its time of occurrence and duration, are permanently recorded and can be replayed as many times as necessary thereafter to retrieve the data. The system is particularly applicable for studies of behavior and predation, for counting individuals, or recording difficult to observe activities. The system can be run continuously for several weeks by two people, reducing personnel costs. This paper is intended to provide biologists who have litte knowledge of electronics with a system that might be useful to their specific needs. The disadvantages of this system are the initial costs (about $9800 basic, 1990-1991 U.S. dollars) and the time required to playback video cassette tapes for data retrieval, but the playback can be sped up when litte or no activity of interest is taking place. In our study, the positive aspects of the system far outweighed the negative.

  4. 24-Hour ICH Score Is a Better Predictor of Outcome than Admission ICH Score

    PubMed Central

    Aysenne, Aimee M.; Albright, Karen C.; Mathias, Tiffany; Chang, Tiffany R.; Boehme, Amelia K.; Beasley, T. Mark; Martin-Schild, Sheryl

    2016-01-01

    Background The ICH score is a validated tool for predicting 30-day morbidity and mortality in patients with intracerebral hemorrhage. Aims and/or Hypothesis The aim of this study is to determine if the ICH score calculated 24 hours after admission is a better predictor of mortality than the ICH score calculated on admission. Methods Patients presenting to our center with ICH from 7/08-12/10 were retrospectively identified from our prospective stroke registry. ICH scores were calculated based on initial Glasgow coma scale (GCS) and emergent head computed tomography (CT) on initial presentation and were recalculated after 24 hours. Results A total of 91 patients out of 121 had complete data for admission and 24-hour ICH score. The ICH score changed in 38% from baseline to 24 hours. After adjusting for age, NIHSS on admission, and glucose, ICH score at 24 hours was a significant, independent predictor of mortality (OR = 2.71, 95% CI 1–19–6.20, and P = 0.018), but ICH score on admission was not (OR = 2.14, 95% CI 0.88-5.24, and P = 0.095). Conclusion Early determination of the ICH score may incorrectly estimate the severity and expected outcome after ICH. Calculations of the ICH score 24 hours after admission will better predict early outcomes.

  5. Dissociated 24-hour patterns of somatotropin and prolactin in fatal familial insomnia.

    PubMed

    Portaluppi, F; Cortelli, P; Avoni, P; Vergnani, L; Maltoni, P; Pavani, A; Sforza, E; Manfredini, R; Montagna, P; Roiter, I

    1995-06-01

    To assess the changes in the 24-hour profiles of serum somatotropin and prolactin levels during total disruption of the sleep/wake cycle sustained over several months, we studied 2 subjects affected by fatal familial insomnia, a rare disease characterized by selective thalamic degeneration that causes chronic sleep loss. Under standardized conditions and polysomnographic control, the patients underwent repeated 24-hour study sessions covering the entire clinical course of the disease. Hormones were assayed at 30-min intervals. Four healthy volunteers were used as controls. A sleep/wake cycle was always absent in fatal familial insomnia. Serum somatotropin and prolactin concentrations never exceeded the normal range of variation. The nocturnal elevation of somatotropin disappeared simultaneously with sleep loss, whereas a significant 24-hour component of variations in serum prolactin levels was present for months after total disruption of the sleep/wake cycle, with normally placed nocturnal acrophases. Complete obliteration of the 24-hour component was achieved for prolactin only in the advanced stages, through a progressive decrease in 24-hour amplitude of variation. Selective and progressive degeneration of the mediodorsal and anterior ventral nuclei of the thalamus causes an early obliteration of the 24-hour rhythm of somatotropin and a later disappearance of circadian prolactin rhythmicity.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. High energy deficit in an ultraendurance athlete in a 24-hour ultracycling race

    PubMed Central

    Rodríguez, Ferran A.; Iglesias, Xavier; Benítez, Adolfo; Marina, Míchel; Padullés, Josep M.; Torrado, Priscila; Vázquez, Jairo; Knechtle, Beat

    2012-01-01

    This case study examined the nutritional behavior and energy balance in an official finisher of a 24-hour ultracycling race. The food and beverages consumed by the cyclist were continuously weighed and recorded to estimate intake of energy, macronutrients, sodium, and caffeine. In addition, during the race, heart rate was continuously monitored. Energy expenditure was assessed using a heart rate–oxygen uptake regression equation obtained previously from a laboratory test. The athlete (39 years, 175.6 cm, 84.2 kg, maximum oxygen uptake, 64 mL/kg/min) cycled during 22 h 22 min, in which he completed 557.3 km with 8760 m of altitude at an average speed of 25.1 km/h. The average heart rate was 131 beats/min. Carbohydrates were the main macronutrient intake (1102 g, 13.1 g/kg); however, intake was below current recommendations. The consumption of protein and fat was 86 g and 91 g, respectively. He ingested 20.7 L (862 mL/h) of fluids, with sport drinks the main fluid used for hydration. Sodium concentration in relation to total fluid intake was 34.0 mmol/L. Caffeine consumption over the race was 231 mg (2.7 mg/kg). During the race, he expended 15,533 kcal. Total energy intake was 5571 kcal, with 4058 (73%) and 1513 (27%) kcal derived from solids and fluids, respectively. The energy balance resulted in an energy deficit of 9915 kcal. PMID:22481841

  7. Sleep-Disordered Breathing and 24-Hour Blood Pressure Pattern Among Older Adults

    PubMed Central

    White, William B.; Kutner, Michael; Ouslander, Joseph G.; Bliwise, Donald L.

    2009-01-01

    Background To examine the association between sleep-disordered breathing (SDB) and 24-hour blood pressure (BP) pattern among community-dwelling older adults. Methods A convenience sample of 70 community-dwelling older adults, recruited from senior housing, community centers, and learning centers, were admitted to General Clinical Research Center, Emory University Hospital, Atlanta, Ga. Information regarding demographic and clinical history was obtained using questionnaires. Twenty-four–hour BP monitoring in supine position was performed using Spacelabs model 20207. Breathing during sleep was monitored with the use of a modified sleep recording system (Embletta, PDS), which monitors nasal and oral airflow, chest and abdominal movements, and pulse oximetry. Night time–daytime (night-day) BP ratio (average night-time BP divided by daytime BP) was calculated both for systolic and diastolic BPs. Results Sixty-nine participants, mean age 74.9 ± 6.4 years (41 [57%] women), completed the study. The mean apnea-hypopnea index (AHI) was 13 ± 13 per hour of sleep, and 20 participants (29%) had AHI ≥15 per hour of sleep, indicating moderate to severe SDB. Moderate to severe SDB (AHI ≥15 per hour of sleep) was significantly associated with nocturnal hypertension, whereas there was no statistically significant difference in wake-time BP between those with and without moderate to severe SDB. Stepwise multiple regressions showed that AHI independently predicted increased night-day systolic and night-day diastolic BP ratio, even after controlling for nocturia frequency. Conclusions The results indicate increased BP load associated with increased AHI in this group of older adults. This increased BP load may contribute to increased hypertension-related morbidity and disease burden. PMID:19196901

  8. Insights about serum sodium behavior after 24 hours of continuous renal replacement therapy

    PubMed Central

    Romano, Thiago Gomes; Martins, Cassia Pimenta Barufi; Mendes, Pedro Vitale; Besen, Bruno Adler Maccagnan Pinheiro; Zampieri, Fernando Godinho; Park, Marcelo

    2016-01-01

    Objective The aim of this study was to investigate the clinical and laboratorial factors associated with serum sodium variation during continuous renal replacement therapy and to assess whether the perfect admixture formula could predict 24-hour sodium variation. Methods Thirty-six continuous renal replacement therapy sessions of 33 patients, in which the affluent prescription was unchanged during the first 24 hours, were retrieved from a prospective collected database and then analyzed. A mixed linear model was performed to investigate the factors associated with large serum sodium variations (≥ 8mEq/L), and a Bland-Altman plot was generated to assess the agreement between the predicted and observed variations. Results In continuous renal replacement therapy 24-hour sessions, SAPS 3 (p = 0.022) and baseline hypernatremia (p = 0.023) were statistically significant predictors of serum sodium variations ≥ 8mEq/L in univariate analysis, but only hypernatremia demonstrated an independent association (β = 0.429, p < 0.001). The perfect admixture formula for sodium prediction at 24 hours demonstrated poor agreement with the observed values. Conclusions Hypernatremia at the time of continuous renal replacement therapy initiation is an important factor associated with clinically significant serum sodium variation. The use of 4% citrate or acid citrate dextrose - formula A 2.2% as anticoagulants was not associated with higher serum sodium variations. A mathematical prediction for the serum sodium concentration after 24 hours was not feasible. PMID:27410407

  9. The Automated Self-Administered 24-hour dietary recall (ASA24): A resource for researchers, clinicians, and educators from the National Cancer Institute

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Extensive evidence has demonstrated that 24-hour dietary recalls (24HDRs) provide high-quality dietary intake data with minimal bias, making them the preferred tool for monitoring the diets of populations and, increasingly, for studying diet and disease associations. Traditional 24HDRs, however, are...

  10. Microtensile bond strength of resin-resin interfaces after 24-hour and 2-month soaking.

    PubMed

    Leavitt, Curry; Boberick, Kenneth G; Winkler, Sheldon

    2007-01-01

    Evaluate the bond strengths of denture base-repair materials to minimize recurrent failure rate. Use microtensile bond strength (muTBS) testing to evaluate the interfacial bonding strength of 6 commercial denture repair materials after 24-hour and 12-month soaking. Blocks of poly(methyl metacrylate) (PMMA) and Triad were fabricated, fractured, and repaired. Twenty bars (1 x 1 x 30 mm) per group were sectioned from each block parallel to the long axis and approximately 90 degrees to the resin-resin repair interface and stored before muTBS testing in a servo-hydraulic tensile-testing machine. Intact PMMA and Triad bars that had been soaked for 24 hours and 12 months were tested for reference. The 24-hour repair strengths for PMMA ranged from 52% to 84% of original strength. Soaking for 12 months resulted in a 20% decrease in strength for the PMMA control. The 12-month repair strengths for PMMA ranged from 43% to 74% of the 12-month soaked material strength. Triad repair tested 35% of original strength after soaking for 24 hours. Permabond (cyanoacrylate) to PMMA tested 47% of original strength after 24 hours of soaking and 26% of the 12-month soaked material strength. Permabond to Triad tested 30% of original strength after 24 hours of soaking. Permabond and Triad showed a 100% adhesive mode of failure. All other materials tested exhibited either an adhesive mode of failure at the denture base-repair-material interface or a complex cohesive failure within the repair-material interface. The muTBS approach can be used to analyze the resin-resin interface of repaired acrylics. The relatively small standard deviations make the muTBS approach attractive. In this study, muTBS was used to evaluate the repair strength of 6 denture repair materials enabling clinicians to make clinical judgments regarding the strongest repair bond available. PMID:17987865

  11. Agreement between 24-hour salt ingestion and sodium excretion in a controlled environment.

    PubMed

    Lerchl, Kathrin; Rakova, Natalia; Dahlmann, Anke; Rauh, Manfred; Goller, Ulrike; Basner, Mathias; Dinges, David F; Beck, Luis; Agureev, Alexander; Larina, Irina; Baranov, Victor; Morukov, Boris; Eckardt, Kai-Uwe; Vassilieva, Galina; Wabel, Peter; Vienken, Jörg; Kirsch, Karl; Johannes, Bernd; Krannich, Alexander; Luft, Friedrich C; Titze, Jens

    2015-10-01

    Accurately collected 24-hour urine collections are presumed to be valid for estimating salt intake in individuals. We performed 2 independent ultralong-term salt balance studies lasting 105 (4 men) and 205 (6 men) days in 10 men simulating a flight to Mars. We controlled dietary intake of all constituents for months at salt intakes of 12, 9, and 6 g/d and collected all urine. The subjects' daily menus consisted of 27 279 individual servings, of which 83.0% were completely consumed, 16.5% completely rejected, and 0.5% incompletely consumed. Urinary recovery of dietary salt was 92% of recorded intake, indicating long-term steady-state sodium balance in both studies. Even at fixed salt intake, 24-hour urine collection for sodium excretion (UNaV) showed infradian rhythmicity. We defined a ±25 mmol deviation from the average difference between recorded sodium intake and UNaV as the prediction interval to accurately classify a 3-g difference in salt intake. Because of the biological variability in UNaV, only every other daily urine sample correctly classified a 3-g difference in salt intake (49%). By increasing the observations to 3 consecutive 24-hour collections and sodium intakes, classification accuracy improved to 75%. Collecting seven 24-hour urines and sodium intake samples improved classification accuracy to 92%. We conclude that single 24-hour urine collections at intakes ranging from 6 to 12 g salt per day were not suitable to detect a 3-g difference in individual salt intake. Repeated measurements of 24-hour UNaV improve precision. This knowledge could be relevant to patient care and the conduct of intervention trials.

  12. Aldosterone-to-Renin Ratio Is Associated With Reduced 24-Hour Heart Rate Variability and QTc Prolongation in Hypertensive Patients

    PubMed Central

    Grübler, Martin R.; Kienreich, Katharina; Gaksch, Martin; Verheyen, Nicolas; Hartaigh, Bríain Ó.; Fahrleitner-Pammer, Astrid; März, Winfried; Schmid, Johannes; Oberreither, Eva-Maria; Wetzel, Julia; Catena, Cristiana; Sechi, Leonardo A.; Pieske, Burkert; Tomaschitz, Andreas; Pilz, Stefan

    2016-01-01

    Abstract Aldosterone is considered to exert direct effects on the myocardium and the sympathetic nervous system. Both QT time and heart rate (HR) variability (HRV) are considered to be markers of arrhythmic risk and autonomous dysregulation. In this study, we investigated the associations between aldosterone, QT time, and HRV in patients with arterial hypertension. We recruited 477 hypertensive patients (age: 60.2 ± 10.2 years; 52.3% females) with a mean systolic/diastolic 24-hour ambulatory blood pressure monitoring (ABPM) value of 128 ± 12.8/77.1 ± 9.2 mmHg and with a median of 2 (IQR: 1–3) antihypertensive agents. Patients were recruited from the outpatient clinic at the Department of Internal Medicine of the Medical University of Graz, Austria. Blood samples, 24-hour HRV derived from 24-hour blood pressure monitoring (ABPM) and ECG's were obtained. Plasma aldosterone and plasma renin concentrations were measured by means of a radioimmunoassay. Twenty-four-hour urine specimens were collected in parallel with ABPM. Mean QTc was 423.3 ± 42.0 milliseconds for males and 434.7 ± 38.3 milliseconds for females. Mean 24H-HR and 24H-HRV was 71.9 ± 9.8 and 10.0 ± 3.6 bpm, respectively. In linear regression analyses adjusted for age, sex, body mass index, ABPM, and current medication, aldosterone to active renin ratio (AARR) was significantly associated with the QTc interval, a marker for cardiac repolarization abnormalities (mean = 426 ± 42.4 milliseconds; β-coefficient = 0.121; P = 0.03) as well as with the 24-hour heart rate variability a surrogate for autonomic dysfunction (median = 9.67 [IQR = 7.38–12.22 bpm]; β-coefficient = −0.133; P = 0.01). In hypertensive patients, AARR is significantly related to QTc prolongation as well as HRV. Further studies investigating the effects of mineralocorticoid receptor blocker and aldosterone synthase inhibitors on QTc and HRV are warranted

  13. Usability of a smartphone food picture app for assisting 24-hour dietary recall: a pilot study

    PubMed Central

    Pope, Benjamin T.; Bilgiç, Pelin; Orr, Barron J.; Suzuki, Asuka; Kim, Angela Sarah; Merchant, Nirav C.; Roe, Denise J.

    2015-01-01

    BACKGROUND/OBJECTIVES The Recaller app was developed to help individuals record their food intakes. This pilot study evaluated the usability of this new food picture application (app), which operates on a smartphone with an embedded camera and Internet capability. SUBJECTS/METHODS Adults aged 19 to 28 years (23 males and 22 females) were assigned to use the Recaller app on six designated, nonconsecutive days in order to capture an image of each meal and snack before and after eating. The images were automatically time-stamped and uploaded by the app to the Recaller website. A trained nutritionist administered a 24-hour dietary recall interview 1 day after food images were taken. Participants' opinions of the Recaller app and its usability were determined by a follow-up survey. As an evaluation indicator of usability, the number of images taken was analyzed and multivariate Poisson regression used to model the factors determining the number of images sent. RESULTS A total of 3,315 food images were uploaded throughout the study period. The median number of images taken per day was nine for males and 13 for females. The survey showed that the Recaller app was easy to use, and 50% of the participants would consider using the app daily. Predictors of a higher number of images were as follows: greater interval (hours) between the first and last food images sent, weekend, and female. CONCLUSIONS The results of this pilot study provide valuable information for understanding the usability of the Recaller smartphone food picture app as well as other similarly designed apps. This study provides a model for assisting nutrition educators in their collection of food intake information by using tools available on smartphones. This innovative approach has the potential to improve recall of foods eaten and monitoring of dietary intake in nutritional studies. PMID:25861429

  14. The impact of kidney transplantation on 24-hour ambulatory blood pressure in end-stage renal disease patients.

    PubMed

    Lee, Myung Hyun; Ko, Kyung Min; Ahn, Seung Won; Bae, Myoung Nam; Choi, Bum Soon; Park, Cheol Whee; Kim, Yong-Soo; Yang, Chul Woo; Chung, Byung Ha

    2015-06-01

    In this study, we prospectively investigated the impact of kidney transplantation (KT) on the status of hypertension, including circadian rhythm in end-stage renal disease (ESRD) patients. We performed 24-hour ambulatory blood pressure (BP) monitoring and office BP measurement in 48 patients before and 1 year after KT. According to the nocturnal reduction in systolic BP (ΔSBP), the patients were divided into dippers, non-dippers, and reverse dippers. After KT, the mean BP value in office BP and 24-hour ambulatory BP monitoring did not change, but the proportion of patients taking anti-hypertensive drugs and the pill number significantly decreased. In contrast, the mean ΔSBP significantly decreased, and the proportion of non-dippers and reverse dippers did not decrease. Decrease in ΔSBP after KT was associated with inferior allograft function during follow-up. Our study suggests that KT improved the overall BP level, but it did not affect abnormal circadian rhythm in ESRD patients. PMID:26051924

  15. Mood-Dependent Cognitive Change in a Man with Bipolar Disorder Who Cycles Every 24 Hours

    ERIC Educational Resources Information Center

    Lam, Dominic; Mansell, Warren

    2008-01-01

    A case study of a bipolar patient whose mood changes every 24 hours is described to illustrate the changes in cognitive processing and content during different phases of bipolar disorder. The participant completed a battery of questionnaires and tasks on 4 separate occasions: twice when depressed and twice when manic. Depression tended to be…

  16. Leg skinfold thicknesses and race performance in male 24-hour ultra-marathoners.

    PubMed

    Knechtle, Beat; Knechtle, Patrizia; Rüst, Christoph Alexander; Rosemann, Thomas

    2011-04-01

    The association of skinfold thicknesses with race performance has been investigated in runners competing over distances of ≤50 km. This study investigated a potential relation between skinfold thicknesses and race performance in male ultra-marathoners completing >50 km in 24 hours. Variables of anthropometry, training, and previous performance were related to race performance in 63 male ultra-marathoners aged 46.9 (standard deviation [SD] 10.3) years, standing 1.78 (SD 0.07) m in height, and weighing 73.3 (SD 7.6) kg. The runners clocked 146.1 (SD 43.1) km during the 24 hours. In the bivariate analysis, several variables were associated with race performance: body mass (r = -0.25); skinfold thickness at axilla (r = -0.37), subscapula (r = -0.28), abdomen (r = -0.31), and suprailiaca (r = -0.30); the sum of skinfold thicknesses (r = -0.32); percentage body fat (r = -0.32); weekly kilometers run (r = 0.31); personal best time in a marathon (r = -0.58); personal best time in a 100-km ultra-run (r = -0.31); and personal best performance in a 24-hour run (r = 0.46). In the multivariate analysis, no anthropometric or training variable was related to race performance. In conclusion, in contrast to runners up to distances of 50 km, skinfold thicknesses of the lower limbs were not related to race performance in 24-hour ultra-marathoners.

  17. The Three-Continent, 24-Hour Help Desk: An Academic First?

    ERIC Educational Resources Information Center

    Sykes, Jean

    2002-01-01

    Describes Follow the Sun, a computer help-desk service that takes advantage of time differences around the world to permit four universities (University of Colorado Boulder, Australia's Macquarie and Newcastle universities, and the London School of Economics) to share services and provide 24-hour support to users. (EV)

  18. Assessing dietary intake in childhood cancer survivors: Food frequency questionnaire versus 24-hour diet recalls

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet r...

  19. Measurement error corrected sodium and potassium intake estimation using 24-hour urinary excretion.

    PubMed

    Huang, Ying; Van Horn, Linda; Tinker, Lesley F; Neuhouser, Marian L; Carbone, Laura; Mossavar-Rahmani, Yasmin; Thomas, Fridtjof; Prentice, Ross L

    2014-02-01

    Epidemiological studies of the association of sodium and potassium intake with cardiovascular disease risk have almost exclusively relied on self-reported dietary data. Here, 24-hour urinary excretion assessments are used to correct the dietary self-report data for measurement error under the assumption that 24-hour urine recovery provides a biomarker that differs from usual intake according to a classical measurement model. Under this assumption, dietary self-reports underestimate sodium by 0% to 15%, overestimate potassium by 8% to 15%, and underestimate sodium/potassium ratio by ≈20% using food frequency questionnaires, 4-day food records, or three 24-hour dietary recalls in Women's Health Initiative studies. Calibration equations are developed by linear regression of log-transformed 24-hour urine assessments on corresponding log-transformed self-report assessments and several study subject characteristics. For each self-report method, the calibration equations turned out to depend on race and age and strongly on body mass index. After adjustment for temporal variation, calibration equations using food records or recalls explained 45% to 50% of the variation in (log-transformed) 24-hour urine assessments for sodium, 60% to 70% of the variation for potassium, and 55% to 60% of the variation for sodium/potassium ratio. These equations may be suitable for use in epidemiological disease association studies among postmenopausal women. The corresponding signals from food frequency questionnaire data were weak, but calibration equations for the ratios of sodium and potassium/total energy explained ≈35%, 50%, and 45% of log-biomarker variation for sodium, potassium, and their ratio, respectively, after the adjustment for temporal biomarker variation and may be suitable for cautious use in epidemiological studies. Clinical Trial Registration- URL: www.clinicaltrials.gov. Unique identifier: NCT00000611.

  20. Seasonal changes of 24-hour intraocular pressure rhythm in healthy Shanghai population

    PubMed Central

    Cheng, Jingyi; Xiao, Ming; Xu, Huan; Fang, Shaobin; Chen, Xu; Kong, Xiangmei; Sun, Xinghuai

    2016-01-01

    Abstract The aim of the present study was to investigate and compare the 24-hour intraocular pressure (IOP) rhythms in winter and summer in the healthy population of Shanghai, China. This is a cross-sectional study in which 24-hour IOP measurements were taken for all eligible healthy volunteers in winter and summer, respectively, and the temperature, hours of sunlight (sunlight time), and circulatory parameters, including heart rate, systolic blood pressure, and diastolic blood pressure, were also recorded. The 24-hour IOP curves and IOP parameters (mean, peak, trough, and fluctuation of IOP together with the diurnal-to-nocturnal IOP change) in winter and summer were obtained and compared. The magnitude of IOP changes from summer to winter was also calculated. A total of 29 participants (58 eyes), 14 (48.28%) male and 15 (51.72%) female, aged 43.66 ± 12.20 (19–61) years, were considered eligible for this study. Generally, IOP decreased progressively before noon, increased notably in the nocturnal period, and peaked at 12:00 am in winter and at 2:00 am in summer. The pattern of 24-hour IOP in winter and summer was significantly different (P = 0.002). The average IOPs from 4:00 pm to 8:00 am, except for 6:00 am, were significantly higher in winter (P < 0.05). However, no significant differences were shown after adjusting for temperature and/or sunlight time. From summer to winter, the extent of IOP increase was mostly around 0 to 3 mm Hg, and the IOPs increased more significantly in the nocturnal period than in the diurnal period (P = 0.05). The 24-hour IOP rhythms were different in winter and summer, with higher IOP level in winter. Temperature and sunlight time, which are independent of heart rate and blood pressure, affected the 24-hour IOP rhythms in healthy people in Shanghai, China. Further investigations are expected for the rhythm of some endogenous substance secretion and the inner mechanism of regulation of IOP. PMID:27495076

  1. Predicting utility of exercise tests based on history/holter in patients with premature ventricular contractions.

    PubMed

    Robinson, Brad; Xie, Li; Temple, Joel; Octavio, Jenna; Srayyih, Maytham; Thacker, Deepika; Kharouf, Rami; Davies, Ryan; Gidding, Samuel S

    2015-01-01

    Premature ventricular contractions (PVCs) are considered benign in patients with structurally normal hearts, particularly if they suppress with exercise. Catecholaminergic polymorphic ventricular tachycardia (CPVT) requires exercise testing to unmask the malignant phenotype. We studied risk factors and Holter monitor variables to help predict the necessity of exercise testing in patients with PVCs. We retrospectively reviewed 81 patients with PVCs that suppressed at peak exercise and structurally normal hearts referred to the exercise laboratory in 2011. We reviewed 11 patients from 2003 to 2012 whose PVCs were augmented at peak exercise (mean age 13 ± 4 years; 52 % male, 180 exercise studies). We recorded clinical risk factors and comorbidities (family history of arrhythmia or sudden unexpected death [SUD], presence of syncope) and Holter testing parameters. Family history of VT or SUD (P = 0.011) and presence of VT on Holter (P = 0.011) were significant in predicting failure of PVCs to suppress at peak heart rate on exercise testing. Syncope was not statistically significant in predicting suppression (P = 0.18); however, CPVT was diagnosed in four patients with syncope during exercise. Quantity of PVCs, Lown grade, couplets on Holter, monomorphism, and PVC elimination at peak heart rate on Holter were not predictors of PVC suppression on exercise testing. Patients with syncope during exercise, family history of arrhythmia or SUD, or a Holter monitor showing VT warrant exercise testing to assess for CPVT.

  2. Pulmonary function in mechanically-ventilated patients during 24-hour use of a hygroscopic condensor humidifier.

    PubMed

    MacIntyre, N R; Anderson, H R; Silver, R M; Schuler, F R; Coleman, R E

    1983-11-01

    Hygroscopic condensor humidifiers (HCH) are reportedly capable of humidifying even the driest of ventilator source gases with at least 30 mg H2O/liter of ventilation. To assess the adequacy of the HCH during mechanical ventilation, we studied 26 patients over a 72-hour period (alternating 24-hour periods of humidification by a conventional cascade and the HCH). In these patients, we found no significant difference in static lung compliance, airway resistance, PaO2, and PaCO2 on either system. Additionally, estimates of sputum volume (over a four-hour collection period) and clearance of aerosolized 99mTc labelled DTPA (in five of these patients) also showed no significant differences between the two systems. We conclude that the HCH is capable of supplying necessary heat and moisture to most mechanically-ventilated patients for at least a period of 24 hours.

  3. [Contraceptive effect of spermicide on cervical mucus in vivo after 24 hours (authors transl)].

    PubMed

    Batallan, L; Brissi, J; Commerot, J

    1980-10-01

    Efficacy of Alpagelle, a vaginal contraceptive jelly containing benzalkonium chlorohydrate, was tested on 34 women who had been using it for some. The testing was conducted using fresh human spermatozoa, and measuring the penetration into the cervical mucus 24 hours after instillation of 2 ml. of Alpagelle. Maximum penetration of spermatozoa before immobilization and death was 2/10 mm., while it is 2mm. a minute under normal conditions. Alpagelle has no contraindications, and only 1 application every 24 hours will provide contraceptive protection; such method could be ideal for women presenting temporary or permanent contraindications to the IUD, or to the pill, or to those who wish to opt for a method free of side effects. PMID:12262152

  4. Circadian Polymorphisms in Night Owls, in Bipolars, and in Non-24-Hour Sleep Cycles

    PubMed Central

    Klimecki, Walter T.; Nievergelt, Caroline M.; Rex, Katharine M.; Murray, Sarah S.; Shekhtman, Tatyana; Tranah, Gregory J.; Loving, Richard T.; Lee, Heon-Jeong; Rhee, Min Kyu; Shadan, Farhad F.; Poceta, J. Steven; Jamil, Shazia M.; Kline, Lawrence E.; Kelsoe, John R.

    2014-01-01

    People called night owls habitually have late bedtimes and late times of arising, sometimes suffering a heritable circadian disturbance called delayed sleep phase syndrome (DSPS). Those with DSPS, those with more severe progressively-late non-24-hour sleep-wake cycles, and those with bipolar disorder may share genetic tendencies for slowed or delayed circadian cycles. We searched for polymorphisms associated with DSPS in a case-control study of DSPS research participants and a separate study of Sleep Center patients undergoing polysomnography. In 45 participants, we resequenced portions of 15 circadian genes to identify unknown polymorphisms that might be associated with DSPS, non-24-hour rhythms, or bipolar comorbidities. We then genotyped single nucleotide polymorphisms (SNPs) in both larger samples, using Illumina Golden Gate assays. Associations of SNPs with the DSPS phenotype and with the morningness-eveningness parametric phenotype were computed for both samples, then combined for meta-analyses. Delayed sleep and "eveningness" were inversely associated with loci in circadian genes NFIL3 (rs2482705) and RORC (rs3828057). A group of haplotypes overlapping BHLHE40 was associated with non-24-hour sleep-wake cycles, and less robustly, with delayed sleep and bipolar disorder (e.g., rs34883305, rs34870629, rs74439275, and rs3750275 were associated with n=37, p=4.58E-09, Bonferroni p=2.95E-06). Bright light and melatonin can palliate circadian disorders, and genetics may clarify the underlying circadian photoperiodic mechanisms. After further replication and identification of the causal polymorphisms, these findings may point to future treatments for DSPS, non-24-hour rhythms, and possibly bipolar disorder or depression. PMID:25395965

  5. Exercising in the Fasted State Reduced 24-Hour Energy Intake in Active Male Adults

    PubMed Central

    Deitrick, Ronald W.; Hillman, Angela R.

    2016-01-01

    The effect of fasting prior to morning exercise on 24-hour energy intake was examined using a randomized, counterbalanced design. Participants (12 active, white males, 20.8 ± 3.0 years old, VO2max: 59.1 ± 5.7 mL/kg/min) fasted (NoBK) or received breakfast (BK) and then ran for 60 minutes at 60%  VO2max. All food was weighed and measured for 24 hours. Measures of blood glucose and hunger were collected at 5 time points. Respiratory quotient (RQ) was measured during exercise. Generalized linear mixed models and paired sample t-tests examined differences between the conditions. Total 24-hour (BK: 19172 ± 4542 kJ versus NoBK: 15312 ± 4513 kJ; p < 0.001) and evening (BK: 12265 ± 4278 kJ versus NoBK: 10833 ± 4065; p = 0.039) energy intake and RQ (BK: 0.90 ± 0.03 versus NoBK: 0.86 ± 0.03; p < 0.001) were significantly higher in BK than NoBK. Blood glucose was significantly higher in BK than NoBK before exercise (5.2 ± 0.7 versus 4.5 ± 0.6 mmol/L; p = 0.025). Hunger was significantly lower for BK than NoBK before exercise, after exercise, and before lunch. Blood glucose and hunger were not associated with energy intake. Fasting before morning exercise decreased 24-hour energy intake and increased fat oxidation during exercise. Completing exercise in the morning in the fasted state may have implications for weight management. PMID:27738523

  6. Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence

    PubMed Central

    Malik, Rena D.; Cohn, Joshua A.; Fedunok, Pauline A.; Chung, Doreen E.; Bales, Gregory T.

    2016-01-01

    ABSTRACT Purpose: Decision-making regarding surgery for post-prostatectomy incontinence (PPI) is challenging. The 24-hour pad weight test is commonly used to objectively quantify PPI. However, pad weight may vary based upon activity level. We aimed to quantify variability in pad weights based upon patient-reported activity. Materials and Methods: 25 patients who underwent radical prostatectomy were prospectively enrolled. All patients demonstrated clinical stress urinary incontinence without clinical urgency urinary incontinence. On three consecutive alternating days, patients submitted 24-hour pad weights along with a short survey documenting activity level and number of pads used. Results: Pad weights collected across the three days were well correlated to the individual (ICC 0.85 (95% CI 0.74–0.93), p<0.001). The mean difference between the minimum pad weight leakage and maximum leakage per patient was 133.4g (95% CI 80.4–186.5). The mean increase in 24-hour leakage for a one-point increase in self-reported activity level was 118.0g (95% CI 74.3–161.7, p<0.001). Pad weights also varied significantly when self-reported activity levels did not differ (mean difference 51.2g (95% CI 30.3–72.1), p<0.001). Conclusions: 24-hour pad weight leakage may vary significantly on different days of collection. This variation is more pronounced with changes in activity level. Taking into account patient activity level may enhance the predictive value of pad weight testing. PMID:27256187

  7. Circadian polymorphisms in night owls, in bipolars, and in non-24-hour sleep cycles.

    PubMed

    Kripke, Daniel F; Klimecki, Walter T; Nievergelt, Caroline M; Rex, Katharine M; Murray, Sarah S; Shekhtman, Tatyana; Tranah, Gregory J; Loving, Richard T; Lee, Heon-Jeong; Rhee, Min Kyu; Shadan, Farhad F; Poceta, J Steven; Jamil, Shazia M; Kline, Lawrence E; Kelsoe, John R

    2014-10-01

    People called night owls habitually have late bedtimes and late times of arising, sometimes suffering a heritable circadian disturbance called delayed sleep phase syndrome (DSPS). Those with DSPS, those with more severe progressively-late non-24-hour sleep-wake cycles, and those with bipolar disorder may share genetic tendencies for slowed or delayed circadian cycles. We searched for polymorphisms associated with DSPS in a case-control study of DSPS research participants and a separate study of Sleep Center patients undergoing polysomnography. In 45 participants, we resequenced portions of 15 circadian genes to identify unknown polymorphisms that might be associated with DSPS, non-24-hour rhythms, or bipolar comorbidities. We then genotyped single nucleotide polymorphisms (SNPs) in both larger samples, using Illumina Golden Gate assays. Associations of SNPs with the DSPS phenotype and with the morningness-eveningness parametric phenotype were computed for both samples, then combined for meta-analyses. Delayed sleep and "eveningness" were inversely associated with loci in circadian genes NFIL3 (rs2482705) and RORC (rs3828057). A group of haplotypes overlapping BHLHE40 was associated with non-24-hour sleep-wake cycles, and less robustly, with delayed sleep and bipolar disorder (e.g., rs34883305, rs34870629, rs74439275, and rs3750275 were associated with n=37, p=4.58E-09, Bonferroni p=2.95E-06). Bright light and melatonin can palliate circadian disorders, and genetics may clarify the underlying circadian photoperiodic mechanisms. After further replication and identification of the causal polymorphisms, these findings may point to future treatments for DSPS, non-24-hour rhythms, and possibly bipolar disorder or depression. PMID:25395965

  8. Impedance and electrically evoked compound action potential (ECAP) drop within 24 hours after cochlear implantation.

    PubMed

    Chen, Joshua Kuang-Chao; Chuang, Ann Yi-Chiun; Sprinzl, Georg Mathias; Tung, Tao-Hsin; Li, Lieber Po-Hung

    2013-01-01

    Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈ 2.5 cm) and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001). There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes with long

  9. Impedance and Electrically Evoked Compound Action Potential (ECAP) Drop within 24 Hours after Cochlear Implantation

    PubMed Central

    Chen, Joshua Kuang-Chao; Chuang, Ann Yi-Chiun; Sprinzl, Georg Mathias; Tung, Tao-Hsin; Li, Lieber Po-Hung

    2013-01-01

    Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈2.5 cm) and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001). There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes with long

  10. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice

    PubMed Central

    Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-01-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders. PMID:27609090

  11. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice

    NASA Astrophysics Data System (ADS)

    Chu, Xixia; Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-09-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders.

  12. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice.

    PubMed

    Chu, Xixia; Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-01-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders. PMID:27609090

  13. Validation of triple pass 24-hour dietary recall in Ugandan children by simultaneous weighed food assessment

    PubMed Central

    Olupot-Olupot, Peter; Engoru, Charles; Ssenyondo, Tonny; Nteziyaremye, Julius; Amorut, Denis; Nakuya, Margaret; Arimi, Margaret; Frost, Gary; Maitland, Kathryn

    2016-01-01

    Background Undernutrition remains highly prevalent in African children, highlighting the need for accurately assessing dietary intake. In order to do so, the assessment method must be validated in the target population. A triple pass 24 hour dietary recall with volumetric portion size estimation has been described but not previously validated in African children. This study aimed to establish the relative validity of 24-hour dietary recalls of daily food consumption in healthy African children living in Mbale and Soroti, eastern Uganda compared to simultaneous weighed food records. Methods Quantitative assessment of daily food consumption by weighed food records followed by two independent assessments using triple pass 24-hour dietary recall on the following day. In conjunction with household measures and standard food sizes, volumes of liquid, dry rice, or play dough were used to aid portion size estimation. Inter-assessor agreement, and agreement with weighed food records was conducted primarily by Bland-Altman analysis and secondly by intraclass correlation coefficients and quartile cross-classification. Results 19 healthy children aged 6 months to 12 years were included in the study. Bland-Altman analysis showed 24-hour recall only marginally under-estimated energy (mean difference of 149kJ or 2.8%; limits of agreement -1618 to 1321kJ), protein (2.9g or 9.4%; -12.6 to 6.7g), and iron (0.43mg or 8.3%; -3.1 to 2.3mg). Quartile cross-classification was correct in 79% of cases for energy intake, and 89% for both protein and iron. The intraclass correlation coefficient between the separate dietary recalls for energy was 0.801 (95% CI, 0.429-0.933), indicating acceptable inter-observer agreement. Conclusions Dietary assessment using 24-hour dietary recall with volumetric portion size estimation resulted in similar and acceptable estimates of dietary intake compared with weighed food records and thus is considered a valid method for daily dietary intake assessment of

  14. Static stretching can impair explosive performance for at least 24 hours.

    PubMed

    Haddad, Monoem; Dridi, Amir; Chtara, Moktar; Chaouachi, Anis; Wong, Del P; Behm, David; Chamari, Karim

    2014-01-01

    The aim of this study was to compare the effects of static vs. dynamic stretching (DS) on explosive performances and repeated sprint ability (RSA) after a 24-hour delay. Sixteen young male soccer players performed 15 minutes of static stretching (SS), DS, or a no-stretch control condition (CC) 24 hours before performing explosive performances and RSA tests. This was a within-subject repeated measures study with SS, DS, and CC being counterbalanced. Stretching protocols included 2 sets of 7 minutes 30 seconds (2 repetitions of 30 seconds with a 15-second passive recovery) for 5 muscle groups (quadriceps, hamstring, calves, adductors, and hip flexors). Twenty-four hours later (without any kind of stretching in warm-up), the players were tested for the 30-m sprint test (with 10- and 20-m lap times), 5 jump test (5JT), and RSA test. Significant differences were observed between CC, SS, and DS with 5JT (F = 9.99, p < 0.00, effect size [ES] = 0.40), 10-m sprint time (F = 46.52, p < 0.00, ES = 0.76), 20-m sprint time (F = 18.44, p < 0.000, ES = 0.55), and 30-m sprint time (F = 34.25, p < 0.000, ES = 0.70). The significantly better performance (p < 0.05) was observed after DS as compared with that after CC and SS in 5JT, and sprint times for 10, 20, and 30 m. In contrast, significantly worse performance (p < 0.05) was observed after SS as compared with that after CC in 5JT, and sprint times for 10, 20, and 30 m. With RSA, no significant difference was observed between different stretching protocols in the total time (F = 1.55, p > 0.05), average time (F = 1.53, p > 0.05), and fastest time (F = 2.30, p > 0.05), except for the decline index (F = 3.54, p < 0.04, ES = 0.19). Therefore, the SS of the lower limbs and hip muscles had a negative effect on explosive performances up to 24 hours poststretching with no major effects on the RSA. Conversely, the DS of the same muscle groups are highly recommended 24 hours before performing sprint and long-jump performances. In

  15. Influence of Overweight on 24-Hour Urine Chemistry Studies and Recurrent Urolithiasis in Children

    PubMed Central

    Chung, Jae Dong; Kim, Tae-Hyoung; Myung, Soon Chul; Moon, Young Tae; Kim, Kyung Do

    2012-01-01

    Purpose We investigated the influence of overweight on 24-hour urine chemistry studies and recurrent urolithiasis (UL) in children. Materials and Methods A retrospective cohort study was designed to assess children who presented with UL at a pediatric institution between 1985 and 2010. We calculated body mass index percentile (BMIp) adjusted for gender and age according to the 2007 Korean Children and Adolescents Growth Chart and stratified the children into 3 BMI categories: lower body weight (LBW, BMIp≤10), normal BW (NBW, 1024-hour urine chemistry studies did not differ significantly between the three groups. Mean urine citrate levels were lower (0.273±0.218 mg/mg/d vs. 0.429±0.299 mg/mg/d, p<0.05) and the incidence of hypocitraturia was higher (81.5% vs. 45.7%, p<0.05)) in the recurrent stone former group. In the univariate analysis, hypocitraturia and acidic urinary pH were risk factors, but in the multivariate analysis, only hypocitraturia was a risk factor for stone recurrence (hazard ratio, 3.647; 95% confidence interval, 1.047 to 12.703). In the Kaplan-Meier curve, the hypocitraturia group showed higher recurrence than did the normocitraturia group (p<0.05). Conclusions Unlike in adults, in children, overweight adjusted for gender and age was not associated with 24-hour urine chemistry studies and was not a risk factor for recurrent UL. Hypocitraturia was the only risk factor for UL in children. PMID:22536471

  16. Development of an artificial placenta IV: 24 hour venovenous extracorporeal life support in premature lambs.

    PubMed

    Gray, Brian W; El-Sabbagh, Ahmed; Rojas-Pena, Alvaro; Kim, Anne C; Gadepali, Samir; Koch, Kely L; Capizzani, Tony R; Bartlet, Robert H; Mychaliska, George B

    2012-01-01

    An extracorporeal artificial placenta would change the paradigm of treating extremely premature infants. We hypothesized that a venovenous extracorporeal life support (VV-ECLS) artificial placenta would maintain fetal circulation, hemodynamic stability, and adequate gas exchange for 24 hours. A near-term neonatal lamb model (130 days; term = 145 days) was used (n = 9). The right jugular vein was cannulated for VV-ECLS outflow, and an umbilical vein was used for inflow. The circuit included a peristaltic roller pump and a 0.5 m(2) hollow fiber oxygenator. Lambs were maintained on VV-ECLS in an "amniotic bath" for up to 24 hours. Five of nine fetuses survived for 24 hours. In the survivors, average mean arterial pressure was 69 ± 10 mm Hg for the first 4 hours and 36 ± 8 mm Hg for the remaining 20 hours. The mean fetal heart rate was 202 ± 30. Mean VV-ECLS flow was 94 ± 20 ml/kg/min. Using a gas mixture of 50% O(2)/3% CO(2) and sweep flow of 1-2 L/min, the mean pH was 7.27 ± 0.09, with Po(2) of 35 ± 12 mm Hg and Pco(2) of 48 ± 12 mm Hg. Necropsy revealed a patent ductus arteriosus in all cases, and there was no gross or microscopic intracranial hemorrhage. Complications in failed attempts included technically difficult cannulation and multisystem organ failure. Future studies will enhance stability and address the factors necessary for long-term support.

  17. Treating allergic conjunctivitis: A once-daily medication that provides 24-hour symptom relief

    PubMed Central

    Schaeffer, Jack; Donnenfeld, Eric

    2016-01-01

    Background: Allergic conjunctivitis (AC) is a common ocular inflammatory manifestation of allergen exposure in sensitized individuals. Signs and symptoms of AC can decrease quality of life, interfere with productivity, and lead to considerable economic burden. Consistent suppression of conjunctival inflammation is necessary for managing AC, but currently available medications require frequent administration and exhibit limited duration of action. Methods: In this review, we summarized AC pathogenesis, diagnosis, and current treatment options as well as their limitations. Findings from the literature were discussed in the context of the unmet need for a once-daily medication with sustained 24-hour effectiveness. Results: Topical pharmacologic treatments are the most common approach for managing extant AC; however, most available medications require multiple daily instillations. Dual-acting antihistamine-mast cell stabilizing agents are currently considered first-line therapeutics for AC because they provide acute relief of signs and symptoms and block persistent inflammation to promote regression of AC. Recent studies of a newly-developed, higher-concentration formulation of a dual-acting antihistamine-mast cell stabilizer have demonstrated that this formulation provides a 24-hour duration of action with once-daily dosing. Conclusions: Dual-acting AC medications exhibit a high degree of overall effectiveness and are well tolerated for chronic use. A newly available once-daily medication that manages signs and symptoms of AC for a full 24 hours may be considered a treatment of choice for patients experiencing seasonal or perennial AC. ClinicalTrials.gov NCT01743027 and NCT01479374 PMID:27466061

  18. Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions

    PubMed Central

    McVey, Elaine; Keith, Steven; Herr, Joshua K.; Sutter, Diane; Pettis, Ronald J.

    2015-01-01

    Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance. PMID:26319228

  19. 77 FR 65310 - Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... the 2006 24-hour Fine Particle (PM 2.5 ) National Ambient Air Quality Standards,'' 74 FR 58688... Federal Regulations DC District of Columbia EO Executive Order EPA Environmental Protection Agency FR... EPA finalized designations for the 2006 24-hour PM 2.5 NAAQS (74 FR 58688, November 13, 2009), the...

  20. Assessing Dietary Intake in Childhood Cancer Survivors: Food Frequency Questionnaire Versus 24-Hour Diet Recalls.

    PubMed

    Zhang, Fang Fang; Roberts, Susan B; Must, Aviva; Wong, William W; Gilhooly, Cheryl H; Kelly, Michael J; Parsons, Susan K; Saltzman, Edward

    2015-10-01

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet recalls (24HRs) against total energy expenditure (TEE) measured using the doubly labeled water method in 16 childhood cancer survivors. Dietary underreporting, assessed by (EI-TEE)/TEE × 100%, was 22% for FFQ and 1% for repeated 24HRs. FFQ significantly underestimates dietary intake and should not be used to assess the absolute intake of foods and nutrients in childhood cancer survivors.

  1. Nutritional behavior of cyclists during a 24-hour team relay race: a field study report

    PubMed Central

    2012-01-01

    Background Information about behavior of energy intake in ultra-endurance cyclists during a 24-hour team relay race is scarce. The nutritional strategy during such an event is an important factor which athletes should plan carefully before the race. The purpose of this study was to examine and compare the nutritional intake of ultra-endurance cyclists during a 24-hour team relay race with the current nutritional guidelines for endurance events. Additionally, we analyzed the relationship among the nutritional and performance variables. Methods Using a observational design, nutritional intake of eight males (mean ± SD: 36.7 ± 4.7 years; 71.6 ± 4.9 kg; 174.6 ± 7.3 cm; BMI 23.5 ± 0.5 kg/m2) participating in a 24-hour team relay cycling race was assessed. All food and fluid intake by athletes were weighed and recorded. Additionally, distance and speed performed by each rider were also recorded. Furthermore, before to the race, all subjects carried out an incremental exercise test to determine two heart rate-VO2 regression equations which were used to estimate the energy expenditure. Results The mean ingestion of macronutrients during the event was 943 ± 245 g (13.1 ± 4.0 g/kg) of carbohydrates, 174 ± 146 g (2.4 ± 1.9 g/kg) of proteins and 107 ± 56 g (1.5 ± 0.7 g/kg) of lipids, respectively. This amount of nutrients reported an average nutrient intake of 22.8 ± 8.9 MJ which were significantly lower compared with energy expenditure 42.9 ± 6.8 MJ (P = 0.012). Average fluid consumption corresponded to 10497 ± 2654 mL. Mean caffeine ingestion was 142 ± 76 mg. Additionally, there was no relationship between the main nutritional variables (i.e. energy intake, carbohydrates, proteins, fluids and caffeine ingestion) and the main performance variables (i.e. distance and speed). Conclusions A 24-hour hours cycling competition in a team relay format elicited high energy demands which were not compensated by energy intake of the athletes despite that dietary

  2. Assessing Dietary Intake in Childhood Cancer Survivors: Food Frequency Questionnaire versus 24-Hour Diet Recalls

    PubMed Central

    Zhang, Fang Fang; Roberts, Susan B.; Must, Aviva; Wong, William W.; Gilhooly, Cheryl H.; Kelly, Michael J.; Parsons, lkSusan K.; Saltzman, Edward

    2015-01-01

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from food frequency questionnaire (FFQ) and repeated 24-hour diet recalls (24HRs) against total energy expenditure (TEE) measured using the doubly labeled water method in 16 childhood cancer survivors. Dietary underreporting, assessed by (EI-TEE)/TEE ×100%, was 22% for FFQ and 1% for repeated 24HRs. FFQ significantly underestimates dietary intake and should not be used to assess the absolute intake of foods and nutrients in childhood cancer survivors. PMID:25883059

  3. Regional Neurodegeneration and Gliosis Are Amplified by Mild Traumatic Brain Injury Repeated at 24-Hour Intervals

    PubMed Central

    Bolton, Amanda Nicholle; Saatman, Kathryn Eileen

    2014-01-01

    Most traumatic brain injuries (TBIs) that occur every year are classified as ‘mild’. Individuals involved in high-risk activities may sustain multiple mild TBIs. We evaluated the acute physiological and histopathological consequences of mild TBI in a mouse model, comparing sham injury, single impact, or 5 impacts at a 24- or 48-hour inter-injury interval. A single closed skull impact resulted in bilateral gliosis in the hippocampus and entorhinal cortex that was proportional to impact depth. Midline impact, at a depth just above the threshold to induce transient unconsciousness, produced occasional axonal injury and degenerating neurons accompanied by astrogliosis in the entorhinal cortex and cerebellum. Mild TBI repeated every 24 hours resulted in bilateral hemorrhagic lesions in the entorhinal cortex along with significantly increased neurodegeneration and microglial activation despite diminished durations of apnea and unconsciousness with subsequent impacts. Astrogliosis and diffusely distributed axonal injury were also observed bilaterally in the cerebellum and the brainstem. When the interval between mild TBIs was increased to 48 hours, the pathological consequences were comparable to a single TBI. Together, these data suggest that in mice the brain remains at increased risk for damage for 24 hours after mild TBI despite reduced acute physiological responses to subsequent mild impacts. PMID:25232942

  4. A Compute Perspective: Delivering Decision Support Products in 24 Hours from the Airborne Snow Observatory

    NASA Astrophysics Data System (ADS)

    Ramirez, P.; Mattmann, C. A.; Painter, T. H.; Seidel, F. C.; Trangsrud, A.; Hart, A. F.; Goodale, C. E.; Boardman, J. W.; Heneghan, C.; Verma, R.; Khudikyan, S.; Boustani, M.; Zimdars, P. A.; Horn, J.; Neely, S.

    2013-12-01

    The JPL Airborne Snow Observatory (ASO) must process 100s of GB of raw data to 100s of Terabytes of derived data in 24 hour Near Real Time (NRT) latency in a geographically distributed mobile compute and data-intensive processing setting. ASO provides meaningful information to water resource managers in the Western US letting them know how much water to maintain; or release, and what the prospectus of the current snow season is in the Sierra Nevadas. Providing decision support products processed from airborne data in a 24 hour timeframe is an emergent field and required the team to develop a novel solution as this process is typically done over months. We've constructed a system that combines Apache OODT; with Apache Tika; with the Interactive Data Analysis (IDL)/ENVI programming environment to rapidly and unobtrusively generate, distribute and archive ASO data as soon as the plane lands near Mammoth Lakes, CA. Our system is flexible, underwent several redeployments and reconfigurations, and delivered this critical information to stakeholders during the recent "Snow On" campaign March 2013 - June 2013. This talk will take you through a day in the life of the compute team from data acquisition, delivery, processing, and dissemination. Within this context, we will discuss the architecture of ASO; the open source software we used; the data we stored; and how it was delivered to its users. Moreover we will discuss the logistics, system engineering, and staffing that went into the developing, deployment, and operation of the mobile compute system.

  5. Coagulation abnormalities in diabetic coma before and 24 hours after treatment.

    PubMed

    McLaren, E H; Cullen, D R; Brown, M J

    1979-12-01

    A coagulation screen consisting of measurement of the prothrombin time, thrombin time, kaolin caphalin clotting time, platelet count, plasma fibrinogen level, fibrin degradation products and ethanol gelation test was performed on 24 patients with impairment of consciousness due to acute diabetic metabolic decompensation at the start of treatment and 24 hours later. 22 out of 24 patients showed at least one coagulation abnormality on admission of which the commonest were a prolonged prothrombin time, shortened kaolin cephalin clotting.time and raised plasma fibrinogen level. After 24 hours of treatment these values were more normal but 20 out of 22 patients still displayed some abnormality. 15 patients had two or more coagulation abnormalities on admission including 3 patients with haematological abnormalities suggestive of disseminated intravascular coagulation. This group was older and had higher blood ureas than those with fewer abnormalities, but plasma glucose, sodium, potassium and bicarbonate levels were similar in both groups of patients. All 5 patients with hyperosmolar non-ketotic coma and all 3 patients who died without recovering consciousness had two or more coagulation abnormalities on admission.

  6. Deviation of innate circadian period from 24 hours reduces longevity in mice

    PubMed Central

    Libert, Sergiy; Bonkowski, Michael S.; Pointer, Kelli; Pletcher, Scott D.; Guarente, Leonard

    2012-01-01

    Summary The variation of individual lifespans, even in highly inbred cohorts of animals and under strictly controlled environmental conditions, is substantial and not well understood. This variation in part could be due to epigenetic variation, which later affects the animal’s physiology and ultimately longevity. Identification of the physiological properties that impact health and lifespan is crucial for longevity research and the development of anti-aging therapies. Here we measured individual circadian and metabolic characteristics in a cohort of inbred F1 hybrid mice and correlated these parameters to their lifespans. We found that mice with innate circadian periods close to 24 hours (revealed during 30 days of housing in total darkness) enjoyed nearly 20% longer lifespans than their littermates, which had shorter or longer innate circadian periods. These findings show that maintenance of a 24 hour intrinsic circadian period is a positive predictor of longevity. Our data suggest that circadian period may be used to predict individual longevity and that processes that control innate circadian period affect aging. PMID:22702406

  7. Sleep in healthy elderly subjects: a 24-hour ambulatory polysomnographic study.

    PubMed

    Gigli, G L; Placidi, F; Diomedi, M; Maschio, M; Silvestri, G; Scalise, A; Marciani, M G

    1996-04-01

    It is still debated whether the deterioration of the sleep pattern, frequently reported by elderly subjects, is due only to aging per se. Other factors associated with aging or modifications of biological rhythms could also be involved. Elderly subjects frequently complain of daytime sleepiness, but it is not clear whether this actually represents a return to a polyphasic structure of sleep, or only a consequence of a disturbed night sleep. Ten healthy, independent and active elderly subjects (age > 72 years) were elevated by means of 24-hour ambulatory polysomnography. Findings of nocturnal sleep were compared with sleep of the same group in the 24-hour period and with sleep of young healthy controls. We observed a fragmentation of nocturnal sleep, but a fairly good representation of stages and a preservation of cyclicity. Except for three cases, with early or late times of sleep onset and wake-up, sleep disruption did not seem to be related to modification of circadian rhythms. Only three subjects presented undesired daytime naps, whereas the others either did not show daytime sleep at all, or were used to having their siesta after lunch since their young adulthood. In normal aging, daytime sleep does not constitute a social problem. Ambulatory polysomnography is a valid alternative to laboratory recordings in the identification of daytime sleep. PMID:8734563

  8. PHYSICIAN-PHARMACIST CO-MANAGEMENT AND 24-HOUR BLOOD PRESSURE CONTROL

    PubMed Central

    Chen, Ziqian; Ernst, Michael E.; Ardery, Gail; Xu, Yinghui; Carter, Barry L.

    2013-01-01

    The objectives of this study were: to compare indices of 24-hour BP following a physician-pharmacist collaborative intervention and to describe the associated changes in antihypertensive medications. This was a secondary analysis of a prospective, cluster-randomized clinical trial conducted in 6 family medicine clinics randomized to co-managed (n=3 clinics, 176 subjects) or control (n=3 clinics, 198 subjects) groups. Mean ambulatory systolic BP was significantly lower in the co-managed versus the control group: daytime SBP 122.8 mm Hg versus 134.4 mm Hg (p<0.001); nighttime SBP 114.8 mm Hg versus 123.7 mm Hg (p<0.001); and 24-hour SBP 120.4 mm Hg versus 131.8 mm Hg (p<0.001), respectively. Significantly more drug changes were made in the co-managed than in the control group (2.7 versus 1.1 changes/subject, p<0.001), and there was greater diuretic use in co-managed subjects (79.6% versus 62.6%, p<0.001). Ambulatory BPs were significantly lower for the subjects who had a diuretic added during the first month compared with those who never had a diuretic added (p<0.01). Physician-pharmacist co-management significantly improved ambulatory BP compared with a control group. Anti-hypertensive drug therapy was intensified much more for subjects in the co-managed group. PMID:23614849

  9. Association between Sleep Duration and 24-Hour Urine Free Cortisol in the MrOS Sleep Study

    PubMed Central

    Rao, Madhu N.; Blackwell, Terri; Redline, Susan; Punjabi, Naresh M.; Barrett-Connor, Elizabeth; Neylan, Thomas C.; Stone, Katie L.

    2013-01-01

    Context Short sleep duration is associated with adverse health outcomes, but the mechanisms involved are unknown. It has been postulated that short sleep duration may elevate cortisol levels, but studies have had conflicting results. It is unclear whether these differing findings may be due to methodological issues, such as assessment of sleep duration. Specifically, objective versus subjective methods of measuring habitual sleep duration may account for the conflicting results found in epidemiological studies. Objective Our goal was to determine whether habitual sleep duration, measured objectively (by actigraphy) and subjectively (by self-report), was associated with 24-hour urine free cortisol (UFC), a measure of integrated cortisol secretion. Our secondary goal was to determine whether slow wave sleep (SWS, determined by polysomnography) was associated with 24-hour UFC. Design/Setting Cross sectional study of community dwelling older men. Patients/Participants 325 men (mean age = 76.6 years, SD = 5.5) from the Portland site of the MrOS Sleep Study, who underwent 24-hour urine collection, polysomnography, actigraphy and sleep questionnaire. Primary Outcome 24-hour UFC. Results In this study of community dwelling older men, self-reported sleep duration was inversely related to 24-hour UFC levels. Participants reporting <5 hours of habitual sleep had an adjusted mean 24-hour UFC of 29.8 ug, compared to 28.0 ug in participants reporting >5 to <8 hours of sleep 25.5 ug in those reporting >8 hours of habitual sleep. However, sleep duration determined by actigraphy was not associated with 24-hour UFC in either univariable or multivariable regression models. SWS was not associated with 24-hour UFC. Conclusion Objectively measured (i.e., actigraphic) sleep duration is not associated with 24-hour UFC in these community dwelling older men. This finding, together with prior studies, suggests that elevated levels of integrated cortisol secretion is not the

  10. Turbulent diffusion on the solar photosphere through 24-hour continuous observations of magnetic elements

    NASA Astrophysics Data System (ADS)

    Giannattasio, F.; Berrilli, F.; Del Moro, D.; Bellot Rubio, L.; Orozco Suarez, D.; Gosic, M.

    2012-12-01

    Solar atmosphere is a unique laboratory for the study of turbulent flows under extreme conditions (e.g. very high Reynolds numbers). The turbulent nature of the flow may be approached by determining how magnetic flux elements are transported on the solar surface, and measuring the spatio-temporal scales on which these small magnetic structures are organized. The process involved is diffusion. Several works explored this topic, both by simulations and observations, and the results are often contradictory, ranging from fully-developed turbulent scenarios to normal-diffusive motions. We analyze 24-hour continuous Hinode SOT observations of a supergranular region (for the first time these long scales are explored), studying the evolution of the mutual distance between magnetic element pairs and its scaling laws, in order to investigate the diffusion process. We find a super-diffusive behavior, with a gamma index depending on the spatial scale selected.

  11. After 24-hour scrub, another tower rollback for the Boeing Delta II rocket carrying Stardust

    NASA Technical Reports Server (NTRS)

    1999-01-01

    As tower rollback begins, the Boeing Delta II rocket carrying the Stardust spacecraft waits on Launch Pad 17-A, Cape Canaveral Air Station, for the second launch attempt at 4:04 p.m. EST. The original launch was scrubbed on Feb. 6 for 24 hours. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  12. Chest physiotherapy in preterm infants with RDS in the first 24 hours of life.

    PubMed

    Raval, D; Yeh, T F; Mora, A; Cuevas, D; Pyati, S; Pildes, R S

    1987-01-01

    To evaluate if chest physiotherapy is beneficial to premature infants with respiratory distress syndrome (RDS) during the first 24 hours of life, 20 infants were randomly assigned to two groups; 10 infants in Group I received routine chest physiotherapy and suction, and 10 infants in Group II received suction only. The birth weight, gestational age, postnatal age, Apgar scores, blood gases, acid-base status, and ventilatory requirements prior to study were comparable between the two groups. There were no significant differences between the groups in the amount of endotracheal secretions removed, the PO2/FIO2 ratio, blood gases, and pH during the study. The incidence of patent ductus arteriosus (PDA), bronchopulmonary dysplasia (BPD), Grade I and II intraventricular hemorrhage (IVH), and mortality was comparable. However, five of 10 Group I and zero of 10 Group II infants developed Grade III or IV IVH (P less than 0.05).

  13. A 24-Hour Study of the Hypothalamo-Pituitary Axes in Huntington’s Disease

    PubMed Central

    Nambron, Rajasree; Costelloe, Seán J.; Martin, Nicholas G.; Hill, Nathan R.; Frost, Chris; Watt, Hilary C.; Hindmarsh, Peter; Björkqvist, Maria; Warner, Thomas T.

    2015-01-01

    Background Huntington’s disease is an inherited neurodegenerative disorder characterised by motor, cognitive and psychiatric disturbances. Patients exhibit other symptoms including sleep and mood disturbances, muscle atrophy and weight loss which may be linked to hypothalamic pathology and dysfunction of hypothalamo-pituitary axes. Methods We studied neuroendocrine profiles of corticotropic, somatotropic and gonadotropic hypothalamo-pituitary axes hormones over a 24-hour period in controlled environment in 15 healthy controls, 14 premanifest and 13 stage II/III Huntington’s disease subjects. We also quantified fasting levels of vasopressin, oestradiol, testosterone, dehydroepiandrosterone sulphate, thyroid stimulating hormone, free triiodothyronine, free total thyroxine, prolactin, adrenaline and noradrenaline. Somatotropic axis hormones, growth hormone releasing hormone, insulin-like growth factor-1 and insulin-like factor binding protein-3 were quantified at 06:00 (fasting), 15:00 and 23:00. A battery of clinical tests, including neurological rating and function scales were performed. Results 24-hour concentrations of adrenocorticotropic hormone, cortisol, luteinizing hormone and follicle-stimulating hormone did not differ significantly between the Huntington’s disease group and controls. Daytime growth hormone secretion was similar in control and Huntington’s disease subjects. Stage II/III Huntington’s disease subjects had lower concentration of post-sleep growth hormone pulse and higher insulin-like growth factor-1:growth hormone ratio which did not reach significance. In Huntington’s disease subjects, baseline levels of hypothalamo-pituitary axis hormones measured did not significantly differ from those of healthy controls. Conclusions The relatively small subject group means that the study may not detect subtle perturbations in hormone concentrations. A targeted study of the somatotropic axis in larger cohorts may be warranted. However, the lack

  14. Reductions in Mean 24-Hour Ambulatory Blood Pressure After 6-Week Treatment With Canagliflozin in Patients With Type 2 Diabetes Mellitus and Hypertension.

    PubMed

    Townsend, Raymond R; Machin, Israel; Ren, Jimmy; Trujillo, Angelina; Kawaguchi, Masato; Vijapurkar, Ujjwala; Damaraju, Chandrasekharrao V; Pfeifer, Michael

    2016-01-01

    This randomized, double-blind, placebo-controlled study evaluated the early effects of canagliflozin on blood pressure (BP) in patients with type 2 diabetes mellitus (T2DM) and hypertension. Patients were randomized to canagliflozin 300 mg, canagliflozin 100 mg, or placebo for 6 weeks and underwent 24-hour ambulatory BP monitoring before randomization, on day 1 of treatment, and after 6 weeks. The primary endpoint was change in mean 24-hour systolic BP (SBP) from baseline to week 6. Overall, 169 patients were included (mean age, 58.6 years; glycated hemoglobin, 8.1%; seated BP 138.5/82.7 mm Hg). At week 6, canagliflozin 300 mg provided greater reductions in mean 24-hour SBP than placebo (least squares mean -6.2 vs -1.2 mm Hg, respectively; P=.006). Numerical reductions in SBP were observed with canagliflozin 100 mg. Canagliflozin was generally well tolerated, with side effects similar to those reported in previous studies. These results suggest that canagliflozin rapidly reduces BP in patients with T2DM and hypertension.

  15. Attempt Quit Smoking 24+ Hours Maps and Data of Model-Based Small Area Estimates - Small Area Estimates

    Cancer.gov

    Attempt Quit Smoking 24+ Hours is defined as a person 18 years of age or older who must have reported smoking at least 100 cigarettes in his/her life, and now does not smoke at all but it has been less than 365 days since completely stopped smoking cigarettes, or now smoke everyday or some days but reported that have made attempt of quitting for more than 24 hours in the past 12 months.

  16. 12-lead Holter electrocardiography. Review of the literature and clinical application update.

    PubMed

    Su, Li; Borov, Stefan; Zrenner, Bernhard

    2013-06-01

    This brief review is focused on 12-lead Holter electrocardiogram (ECG) recording including a review of the literature and the description of the advantages of its application. The standard 12-lead ECG provides a bedside snapshot of the electrical activity of the heart including vector information, but a snapshot of a few beats for some seconds might miss the whole story. Traditional Holter ECG displaying two or three leads may record all heart beats during a prolonged period, but the limited vector information might be a cause of shortcomings in the ECG diagnosis. The 12-lead Holter ECG overcomes these disadvantages and should be preferred for detecting episodes of arrhythmias, localize their origin or the localization of myocardial ischemia. The 12-lead Holter ECG monitoring is efficient in the evaluation of the effect of drugs or interventional therapeutic procedures, i.e., efficiency of biventricular pacing in patients with heart failure and permanent atrial fibrillation (AF). The automatic analysis of parameters in 12-lead Holter ECG is also providing information for risk stratification. In order to obtain a precise diagnosis based on the criteria established on standard ECG, the "real" 12-lead ECG with ten electrodes is advocated.

  17. Label-free mass spectrometry proteome quantification of human embryonic kidney cells following 24 hours of sialic acid overproduction

    PubMed Central

    2013-01-01

    Background Cell surface glycoprotein sialylation is one of the most ubiquitous glycan modifications found on higher eukaryotes. The surface sialylation pattern of cells is influenced by the cellular environment but also by the Golgi sialyltransferase activity and flux of metabolites through sialic acid producing pathways. Altered cell surface sialic acid patterns have been observed in several cancers and other pathological conditions. In this experiment we examined the cellular proteomic changes that occur in human embryonic kidney cells after 24 hours of sialic acid overproduction using N-Acetylmannosamine. We utilized high resolution mass spectrometry and label free protein quantification to characterize the relative changes in protein abundance as well as multiple reaction monitoring to quantify the cellular sialic acid levels. Results Using N-Acetylmannosamine we were able to induce sialic acid production to almost 70-fold compared to non-induced control cells. Mass spectrometric analysis of cellular proteome of control and induced cells identified 1802 proteins of which 105 displayed significant changes in abundance. Functional analysis of the resulting relative changes in protein abundance revealed regulation of several cellular pathways including protein transport, metabolic and signaling pathways and remodeling of epithelial adherens junctions. We also identified several physically interacting co-regulated proteins in the set of changed proteins. Conclusions In this experiment we show that increased metabolic flux through sialic acid producing pathway affects the abundance of several protein transport, epithelial adherens junction, signaling and metabolic pathway related proteins. PMID:23915316

  18. Once- and twice-daily bevantolol for systemic hypertension using 24-hour ambulatory intraarterial blood pressure recording.

    PubMed

    Al-Khawaja, I M; Caruana, M P; Prince, H; Whittington, J; Raftery, E B

    1986-11-26

    The antihypertensive efficacy of bevantolol, a selective beta 1-adrenoreceptor antagonist, was evaluated in 17 patients with essential hypertension, using continuous ambulatory intraarterial blood pressure (BP) monitoring. The study compared a twice-daily regimen (titrated dose of 200 to 600 mg/day) with the same amount given in a single daily dose. Within-patient comparisons of mean hourly systolic and diastolic BPs and heart rate showed a highly significant effect with twice-daily therapy (p less than 0.001) for all of the 24 hours. Similar significant results were obtained with a single morning dose. There was no difference between the pattern or extent of BP reduction with the 2 regimens. The decrease in BP after bevantolol persisted during the physiologic tests (rest, tilt, isometric and dynamic exercise). Four patients developed minor side effects with the single morning dose, and only 1 patient with the twice-daily regimen. These effects included tiredness, fatigue and dizziness. Unlike pure beta-blocking agents, bevantolol controlled the early morning increase in BP, lending support to the belief that it possesses vasodilatory properties in addition to beta blockade. These results suggest that bevantolol may be useful as first-line therapy in a once-daily dosage for the treatment of essential hypertension.

  19. Hourly thermal load prediction for the next 24 hours by ARIMA, EWMA, LR and an artificial neural network

    SciTech Connect

    Kawashima, Minoru; Dorgan, C.E.; Mitchell, J.W.

    1995-08-01

    Predicting the thermal load for the next 24 hours is essential for optimal control of heating, ventilating, and air conditioning (HVAC) systems that use thermal cool storage. It can be useful in minimizing costs and energy in nonstorage systems. A cooperative research project between a US. university and a Japanese corporation investigated four generally used prediction methods to examine the basic models with variations and to compare the accuracy of each model. A cooling and heating seasonal data set with known next-day weather was used to evaluate the accuracy of each prediction method. The results indicate that an artificial neural network (ANN) model produces the most accurate thermal load predictions. After the initial comparisons with a computer-generated data set, the ANN model was applied to two measured building loads from another research project. These sets included typical measurement noise related to continuous field monitoring. The predictions of the next-day cooling load using the ANN prediction model were close to the actual data, even when the next-day weather was forecast. This confirms that the ANN model has sufficient accuracy and is the correct method for practical utilization in HVAC system control, thermal storage optimal control, and load/demand management.

  20. Time-Based Measurement of Personal Mite Allergen Bioaerosol Exposure over 24 Hour Periods.

    PubMed

    Tovey, Euan R; Liu-Brennan, Damien; Garden, Frances L; Oliver, Brian G; Perzanowski, Matthew S; Marks, Guy B

    2016-01-01

    Allergic diseases such as asthma and rhinitis are common in many countries. Globally the most common allergen associated with symptoms is produced by house dust mites. Although the bed has often been cited as the main site of exposure to mite allergens, surprisingly this has not yet been directly established by measurement due to a lack of suitable methods. Here we report on the development of novel methods to determine the pattern of personal exposure to mite allergen bioaerosols over 24-hour periods and applied this in a small field study using 10 normal adults. Air was sampled using a miniature time-based air-sampler of in-house design located close to the breathing zone of the participants, co-located with a miniature time-lapse camera. Airborne particles, drawn into the sampler at 2L/min via a narrow slot, were impacted onto the peripheral surface of a disk mounted on the hour-hand of either a 12 or 24 hour clock motor. The impaction surface was either an electret cloth, or an adhesive film; both novel for these purposes. Following a review of the time-lapse images, disks were post-hoc cut into subsamples corresponding to eight predetermined categories of indoor or outdoor location, extracted and analysed for mite allergen Der p 1 by an amplified ELISA. Allergen was detected in 57.2% of the total of 353 subsamples collected during 20 days of sampling. Exposure patterns varied over time. Higher concentrations of airborne mite allergen were typically measured in samples collected from domestic locations in the day and evening. Indoor domestic Der p 1 exposures accounted for 59.5% of total exposure, whereas total in-bed-asleep exposure, which varied 80 fold between individuals, accounted overall for 9.85% of total exposure, suggesting beds are not often the main site of exposure. This study establishes the feasibility of novel methods for determining the time-geography of personal exposure to many bioaerosols and identifies new areas for future technical

  1. Non-24-Hour Sleep-Wake Disorder Revisited - A Case Study.

    PubMed

    Garbazza, Corrado; Bromundt, Vivien; Eckert, Anne; Brunner, Daniel P; Meier, Fides; Hackethal, Sandra; Cajochen, Christian

    2016-01-01

    The human sleep-wake cycle is governed by two major factors: a homeostatic hourglass process (process S), which rises linearly during the day, and a circadian process C, which determines the timing of sleep in a ~24-h rhythm in accordance to the external light-dark (LD) cycle. While both individual processes are fairly well characterized, the exact nature of their interaction remains unclear. The circadian rhythm is generated by the suprachiasmatic nucleus ("master clock") of the anterior hypothalamus, through cell-autonomous feedback loops of DNA transcription and translation. While the phase length (tau) of the cycle is relatively stable and genetically determined, the phase of the clock is reset by external stimuli ("zeitgebers"), the most important being the LD cycle. Misalignments of the internal rhythm with the LD cycle can lead to various somatic complaints and to the development of circadian rhythm sleep disorders (CRSD). Non-24-hour sleep-wake disorders (N24HSWD) is a CRSD affecting up to 50% of totally blind patients and characterized by the inability to maintain a stable entrainment of the typically long circadian rhythm (tau > 24.5 h) to the LD cycle. The disease is rare in sighted individuals and the pathophysiology less well understood. Here, we present the case of a 40-year-old sighted male, who developed a misalignment of the internal clock with the external LD cycle following the treatment for Hodgkin's lymphoma (ABVD regimen, four cycles and AVD regimen, four cycles). A thorough clinical assessment, including actigraphy, melatonin profiles and polysomnography led to the diagnosis of non-24-hour sleep-wake disorders (N24HSWD) with a free-running rhythm of tau = 25.27 h. A therapeutic intervention with bright light therapy (30 min, 10,000 lux) in the morning and melatonin administration (0.5-0.75 mg) in the evening failed to entrain the free-running rhythm, although a longer treatment duration and more intense therapy might have

  2. Time-Based Measurement of Personal Mite Allergen Bioaerosol Exposure over 24 Hour Periods

    PubMed Central

    Tovey, Euan R.; Liu-Brennan, Damien; Garden, Frances L.; Oliver, Brian G.; Perzanowski, Matthew S.; Marks, Guy B.

    2016-01-01

    Allergic diseases such as asthma and rhinitis are common in many countries. Globally the most common allergen associated with symptoms is produced by house dust mites. Although the bed has often been cited as the main site of exposure to mite allergens, surprisingly this has not yet been directly established by measurement due to a lack of suitable methods. Here we report on the development of novel methods to determine the pattern of personal exposure to mite allergen bioaerosols over 24-hour periods and applied this in a small field study using 10 normal adults. Air was sampled using a miniature time-based air-sampler of in-house design located close to the breathing zone of the participants, co-located with a miniature time-lapse camera. Airborne particles, drawn into the sampler at 2L/min via a narrow slot, were impacted onto the peripheral surface of a disk mounted on the hour-hand of either a 12 or 24 hour clock motor. The impaction surface was either an electret cloth, or an adhesive film; both novel for these purposes. Following a review of the time-lapse images, disks were post-hoc cut into subsamples corresponding to eight predetermined categories of indoor or outdoor location, extracted and analysed for mite allergen Der p 1 by an amplified ELISA. Allergen was detected in 57.2% of the total of 353 subsamples collected during 20 days of sampling. Exposure patterns varied over time. Higher concentrations of airborne mite allergen were typically measured in samples collected from domestic locations in the day and evening. Indoor domestic Der p 1 exposures accounted for 59.5% of total exposure, whereas total in-bed-asleep exposure, which varied 80 fold between individuals, accounted overall for 9.85% of total exposure, suggesting beds are not often the main site of exposure. This study establishes the feasibility of novel methods for determining the time-geography of personal exposure to many bioaerosols and identifies new areas for future technical

  3. Non-24-Hour Sleep-Wake Disorder Revisited – A Case Study

    PubMed Central

    Garbazza, Corrado; Bromundt, Vivien; Eckert, Anne; Brunner, Daniel P.; Meier, Fides; Hackethal, Sandra; Cajochen, Christian

    2016-01-01

    The human sleep-wake cycle is governed by two major factors: a homeostatic hourglass process (process S), which rises linearly during the day, and a circadian process C, which determines the timing of sleep in a ~24-h rhythm in accordance to the external light–dark (LD) cycle. While both individual processes are fairly well characterized, the exact nature of their interaction remains unclear. The circadian rhythm is generated by the suprachiasmatic nucleus (“master clock”) of the anterior hypothalamus, through cell-autonomous feedback loops of DNA transcription and translation. While the phase length (tau) of the cycle is relatively stable and genetically determined, the phase of the clock is reset by external stimuli (“zeitgebers”), the most important being the LD cycle. Misalignments of the internal rhythm with the LD cycle can lead to various somatic complaints and to the development of circadian rhythm sleep disorders (CRSD). Non-24-hour sleep-wake disorders (N24HSWD) is a CRSD affecting up to 50% of totally blind patients and characterized by the inability to maintain a stable entrainment of the typically long circadian rhythm (tau > 24.5 h) to the LD cycle. The disease is rare in sighted individuals and the pathophysiology less well understood. Here, we present the case of a 40-year-old sighted male, who developed a misalignment of the internal clock with the external LD cycle following the treatment for Hodgkin’s lymphoma (ABVD regimen, four cycles and AVD regimen, four cycles). A thorough clinical assessment, including actigraphy, melatonin profiles and polysomnography led to the diagnosis of non-24-hour sleep-wake disorders (N24HSWD) with a free-running rhythm of tau = 25.27 h. A therapeutic intervention with bright light therapy (30 min, 10,000 lux) in the morning and melatonin administration (0.5–0.75 mg) in the evening failed to entrain the free-running rhythm, although a longer treatment duration and more intense therapy

  4. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion: The 2009-2011 Korea National Health and Nutrition Examination Survey.

    PubMed

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-03-01

    Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286-4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the abovementioned variables

  5. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion: The 2009-2011 Korea National Health and Nutrition Examination Survey.

    PubMed

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-03-01

    Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286-4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the abovementioned variables

  6. What and how much do we eat? 24-hour dietary recall method.

    PubMed

    Salvador Castell, Gemma; Serra-Majem, Lluis; Ribas-Barba, Lourdes

    2015-02-26

    Diet, along with lifestyle factors, is an important determinant of the health status of an individual and of a community. Dietary assessment at the population level provides us with key information on the frequency and distribution of possible inadequate diets and/or nutritional status. It is also useful as input into the elaboration of food and nutrition policies aiming to improve dietary habits and the health status of a community. This article reviews the characteristics, advantages and limitations of the 24-hour dietary recall method (24hDR), which is one of the most widely used tools in nutrition epidemiology to identify food, energy and nutrient intake in national nutrition surveys, cross-sectional studies, clinical trials and cohort studies as well as in the evaluation of individual dietary intake and Total Diet assessment. To reduce the key factors associated with bias, the importance of previously trained interviewers is highlighted, as well as the role of support materials and the contribution of novel technologies.

  7. Severe community-acquired pneumonia: timely management measures in the first 24 hours.

    PubMed

    Phua, Jason; Dean, Nathan C; Guo, Qi; Kuan, Win Sen; Lim, Hui Fang; Lim, Tow Keang

    2016-01-01

    Mortality rates for severe community-acquired pneumonia (CAP) range from 17 to 48 % in published studies.In this review, we searched PubMed for relevant papers published between 1981 and June 2016 and relevant files. We explored how early and aggressive management measures, implemented within 24 hours of recognition of severe CAP and carried out both in the emergency department and in the ICU, decrease mortality in severe CAP.These measures begin with the use of severity assessment tools and the application of care bundles via clinical decision support tools. The bundles include early guideline-concordant antibiotics including macrolides, early haemodynamic support (lactate measurement, intravenous fluids, and vasopressors), and early respiratory support (high-flow nasal cannulae, lung-protective ventilation, prone positioning, and neuromuscular blockade for acute respiratory distress syndrome).While the proposed interventions appear straightforward, multiple barriers to their implementation exist. To successfully decrease mortality for severe CAP, early and close collaboration between emergency medicine and respiratory and critical care medicine teams is required. We propose a workflow incorporating these interventions. PMID:27567896

  8. 24 Hours in the Life of HIV-1 in a T Cell Line

    PubMed Central

    Mohammadi, Pejman; Desfarges, Sébastien; Bartha, István; Joos, Beda; Zangger, Nadine; Muñoz, Miguel; Günthard, Huldrych F.; Beerenwinkel, Niko; Telenti, Amalio; Ciuffi, Angela

    2013-01-01

    HIV-1 infects CD4+ T cells and completes its replication cycle in approximately 24 hours. We employed repeated measurements in a standardized cell system and rigorous mathematical modeling to characterize the emergence of the viral replication intermediates and their impact on the cellular transcriptional response with high temporal resolution. We observed 7,991 (73%) of the 10,958 expressed genes to be modulated in concordance with key steps of viral replication. Fifty-two percent of the overall variability in the host transcriptome was explained by linear regression on the viral life cycle. This profound perturbation of cellular physiology was investigated in the light of several regulatory mechanisms, including transcription factors, miRNAs, host-pathogen interaction, and proviral integration. Key features were validated in primary CD4+ T cells, and with viral constructs using alternative entry strategies. We propose a model of early massive cellular shutdown and progressive upregulation of the cellular machinery to complete the viral life cycle. PMID:23382686

  9. Age and individual sleep characteristics affect cognitive performance in anesthesiology residents after a 24-hour shift.

    PubMed

    Tadinac, Meri; Sekulić, Ante; Hromatko, Ivana; Mazul-Sunko, Branka; Ivancić, Romina

    2014-03-01

    Previous research has shown that both shift work and sleep deprivation have an adverse influence on various aspects of human cognitive performance. The aim of this study was to explore changes in cognitive functioning and subjective sleepiness of anesthesiology residents after a 24-hour shift. Twenty-six anesthesiology residents completed a set of psychological instruments at the beginning and at the end of the shift, as well as a questionnaire regarding information about the shift, Stanford Sleepiness Scale, and Circadian Type Questionnaire. There was a significant decline in cognitive performance measured by the Auditory Verbal Learning Test after the shift. The effect was stronger in older participants and in those with high scores on rigidity of sleep scale and low scores on the ability to overcome sleepiness scale. There were no differences in the digits forward test (a measure of concentration), while digits backward test (a measure of working memory) even showed an improved performance after the shift. Although participants reported being significantly sleepier after the shift, the subjective sleepiness did not correlate with any of the objective measures of cognitive performance. In conclusion, the performance in short tasks involving concentration and working memory was not impaired, while performance in long-term and monotone tasks declined after sleep deprivation, and the magnitude of this decline depended on the specific individual characteristics of sleep and on age Surprisingly, age seemed to have an important impact on cognitive functions after shift work even in the relatively age-homogeneous population of young anesthesiology residents.

  10. Obtaining liver tridimensional scaffold through the decellularization of rabbit whole liver in 24 hours

    NASA Astrophysics Data System (ADS)

    Federico, Schliamser; Ayelen, Rinaldi; Romina, Comin; Alba Nelly, Borchert; Adrian, Nari Gustavo; Alicia, Salvatierra Nancy; Mariana Paula, Cid

    2016-04-01

    In the present work, we development a new protocol for liver decellularization in which the hole decellularization was reached over 24 h. Introduction: the availability of transplantable livers is not sufficient to fulfill the current demand for grafts, with the search for therapeutic alternatives having generated different lines of research, one of which is the use of decellularized three-dimensional biological matrices and subsequent cell seeding to obtain a functional organ. Objective: to produce a decellularization protocol from rabbit liver to generate a three-dimensional matrixin which the time period involved didn't pass 24 h. Methods: The decellularization is obtained through the use of water and SDS (0,1-0,3 %), after freezing at -80 degrees, is the best alternative of different physical and/or chemical mechanisms to break down organ cells and leave only the extracellular matriz. After 24 h of retrograde perfusion, a decellularized translucent matrix was generated. To evaluate if the decellularization protocol was successful, with the extracellular matrix being preserved, we carried out histological (light microscopy) and biochemical (DNA quantification) studies. Results: the decellularization process was verified by macroscopic observation of the organ using microscopic observation corroborated the macroscopic results, with the hematoxylin-eosin and Masson staining showing no cells or nuclear material. In addition, the DNA quantification was less than 10% in the decellularized liver compared to control. Finally,the time taken to develop the decellularization protocol was less than 24 hours.

  11. Depressive Symptoms and 24-Hour Ambulatory Blood Pressure in Africans: The SABPA Study

    PubMed Central

    Hamer, Mark; Frasure-Smith, Nancy; Lespérance, François; Harvey, Brian H.; Malan, Nico T.; Malan, Leoné

    2012-01-01

    Disturbances in circadian rhythm might play a central role in the neurobiology of depression. We examined the association between depressive symptoms and 24-hour ambulatory BP in a sample of 405 (197 black and 208 Caucasian) urbanized African teachers aged 25 to 60 yrs (mean 44.6 ± 9.6 yrs). Depressive symptoms were assessed using the self-administered 9-item Patient Health Questionnaire (PHQ-9). After adjusting for age, sex, and ethnicity, participants with severe depressive symptoms (PHQ-9 ≥ 15) had higher odds of hypertension defined from ambulatory BP and/or use of antihypertensive medication (odds ratio = 2.19, 95% CI, 1.00–4.90) in comparison to participants with no symptoms. Compared to Caucasians with no depressive symptoms, those with severe symptoms had blunted nocturnal systolic BP drop of 4.7 mmHg (95% CI, −0.5 to 10.0, P = 0.07). In summary, depressive symptoms were associated with the circadian BP profile in black and Caucasian Africans. PMID:22028954

  12. Neonatal family care for 24 hours per day: effects on maternal confidence and breast-feeding.

    PubMed

    Wataker, Heidi; Meberg, Alf; Nestaas, Eirik

    2012-01-01

    In family care (FC) program for neonatal intensive care units (NICUs), parents are encouraged to reside together with their infant for 24 hours a day to actively be involved in the care. The aim of this study was to assess the impact of FC on maternal confidence and breast-feeding. Maternal confidence and rate of breast-feeding were assessed in 31 mothers offered FC that included special family rooms in the NICU, and in 30 mothers from a comparable NICU providing traditional care without such facilities. One week prior to hospital discharge, mothers in the FC group felt better informed regarding nursing issues and had more confidence in interpretation of the infants regarding feeding issues and in caregiving without staff attendance (P < .05). They also reported a higher level of empowerment (P < .05). Three months after discharge, the mothers in the FC group had a higher self-reported skill level for interpretation of the infant's signals and knowledge about breast-feeding (P < .05). Despite similar rate of breast-feeding at discharge, more infants in the FC group were breastfed 3 months after discharge (P < .05). An FC program in the NICU promoted better maternal confidence during the hospital stay and 3 months after discharge compared with traditional care.

  13. Importance of all movement behaviors in a 24 hour period for overall health.

    PubMed

    Chaput, Jean-Philippe; Carson, Valerie; Gray, Casey E; Tremblay, Mark S

    2014-12-01

    Physical inactivity and childhood obesity are well-recognized public health concerns that are associated with a range of adverse health outcomes. Historically, the benefits of physical activity (e.g., moderate-to-vigorous physical activity-MVPA) to overall health have dominated discussions and emerging evidence indicates that a broader, more integrated approach is needed to better understand and address current public health crises. Existing guidelines for children and youth around the world only focus on MVPA, and recently sedentary behavior, despite an accumulating body of evidence showing that light-intensity physical activity (LPA) such as walking can provide important health benefits. Furthermore, there is accumulating support for the importance of adequate sleep and that these behaviors moderate the health impact of each other. Ignoring the other components of the movement continuum (i.e., sleep, sedentary time, LPA) while focusing efforts exclusively on MVPA (accounting for <5% of the time in a 24 h period) limits the potential to optimize the health benefits of movement behaviors. In order to address this limitation, experts in Canada are currently developing the world's first Integrated 24 Hour Movement Behaviour Guidelines for Children and Youth to help advance an integrated healthy active living agenda that has the potential to significantly improve the overall health and well-being of children and youth. PMID:25485978

  14. Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

    PubMed

    Parati, Gianfranco; Omboni, Stefano; Palatini, Paolo; Rizzoni, Damiano; Bilo, Grzegorz; Valentini, Mariaconsuelo; Rosei, Enrico Agabiti; Mancia, Giuseppe

    2008-10-01

    This article offers instructions and recommendations on how to perform blood pressure measurements in the doctor's office, in the patient's home and in ambulatory conditions over 24 hours. Great attention is paid to some of the general aspects of blood pressure measurement, including the accuracy of blood pressure measuring devices, the importance of a 'white-coat effect', and the need for patient education. This article also deals with a number of practical details, such as the importance of patient's relaxation and position, arm position and support, arm selection and cuff selection and application. Recommendations are provided on the observer's position and performance, and on the need to pay attention to specific factors affecting the blood pressure measurement in different patient populations, namely in children, elderly and obese people, pregnant women, patients with arrhythmias and patients on treatment. This article then separately focuses on the characteristics of auscultatory and automated measurements, the latter performed either in the office, at home or over 24 hours in ambulatory settings. Home blood pressure monitoring (HBPM) is becoming increasingly important in the diagnosis and management of arterial hypertension. The importance of HBPM in cardiovascular prevention, related to a deeper involvement of patients in their long-term management, and the wide diffusion of this approach in populations, is not always accompanied by adequate knowledge of how to make proper use of this technique, which emphasizes the need for more precise recommendations. This article summarizes the available evidence and provides recommendations on the use of home blood pressure monitoring in clinical practice and in research. It updates the previous recommendations on the same topic issued in 2000. The main topics addressed include the methodology of HBPM, focusing on measurement conditions and procedures, ranging from patient/subject position, to arm selection, arm

  15. Metabolic and renal changes in two athletes during a world 24 hour relay record performance.

    PubMed Central

    Irving, R A; Noakes, T D; van Zyl Smit, R

    1989-01-01

    Metabolic parameters and renal function were studied in two subjects before, during and after they established a world two-man 24 hour relay record. During the race, the athletes expended an estimated 37.747 and 42.880 kJ running at 54 and 61 per cent of maximum oxygen consumption (VO2max). Rectal temperatures reached maxima of 38.6 and 39.2 degrees C respectively during the race. Serum free fatty acid levels peaked at 2108 and 1875 mumol ml-1 after 24 hours; blood glucose levels varied from 4.3-6.5 and 4.9-8.5 mmol.l-1 respectively. Plasma insulin levels fell from 42.9 and 22.7 microU.ml-1 to 11.5 microU.ml-1. Plasma urea, creatinine, beta 2-microglobulin and C-reactive protein concentrations were elevated at the end of the race (to 9.0 and 8.0 mmol.l-1, 119 and 102 mumol.l-1, 3.508 and 3203 micrograms.l-1 and 2.7 and 3.9 mg per cent respectively). Plasma osmolality was altered from 293 and 304 to 302 and 280 mosmol.Kg-1 during the race but increased to 312 and 318 mosmol.Kg-1 the following day probably due to intercompartmental fluid shifts. Plasma creatinine concentration was increased by 38 and 26 per cent due to reduced urinary excretion. Urine flow rate increased 40 and 123 per cent respectively during the race, but creatinine clearance decreased by 38 and 40 per cent. Urine osmolality decreased by 38 and 65 per cent and osmolal clearance decreased by 15 and 16 per cent respectively. Urine sodium excretion was greatly reduced (85 and 90 per cent) on the post-race days (by 88 and 92 per cent on day 2). Both urine total protein and beta2-microglobulin excretion increased during the race (by 89 and 35 per cent and by 334 and 136 per cent respectively), but owing to the increased beta2-microglobulin production renal clearance was unaltered. The changes in renal function were temporary and some aspects of renal tubular function were enhanced during the post-race days. We conclude that, although C-reactive protein concentrations increased sooner and were higher

  16. Methodology for adding glycemic index and glycemic load values to 24-hour dietary recall database

    PubMed Central

    Olendzki, Barbara C.; Ma, Yunsheng; Culver, Annie L.; Ockene, Ira S.; Griffith, Jennifer A.; Hafner, Andrea R.; Hebert, James R.

    2006-01-01

    Objectives We describe a method of adding the glycemic index (GI) and glycemic load (GL) values to the nutrient database of the 24-hour dietary recall interview (24HR), a widely used dietary assessment. We also calculated daily GI and GL values from the 24HR. Methods Subjects were 641 healthy adults from central Massachusetts who completed 9067 24HRs. The 24HR-derived food data were matched to the International Table of Glycemic Index and Glycemic Load Values. The GI values for specific foods not in the table were estimated against similar foods according to physical and chemical factors that determine GI. Mixed foods were disaggregated into individual ingredients. Results Of 1261 carbohydrate-containing foods in the database, GI values of 602 foods were obtained from a direct match (47.7%), accounting for 22.36% of dietary carbohydrate. GI values from 656 foods (52.1%) were estimated, contributing to 77.64% of dietary carbohydrate. The GI values from three unknown foods (0.2%) could not be assigned. The average daily GI was 84 (SD 5.1, white bread as referent) and the average GL was 196 (SD 63). Conclusion Using this methodology for adding GI and GL values to nutrient databases, it is possible to assess associations between GI and/or GL and body weight and chronic disease outcomes (diabetes, cancer, heart disease). This method can be used in clinical and survey research settings where 24HRs are a practical means for assessing diet. The implications for using this methodology compel a broader evaluation of diet with disease outcomes. PMID:17029903

  17. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted.

  18. Executive Functions are not Affected by 24 Hours of Sleep Deprivation: A Color-Word Stroop Task Study

    PubMed Central

    Dixit, Abhinav; Mittal, Tushar

    2015-01-01

    Background: Sleep is an important factor affecting cognitive performance. Sleep deprivation results in fatigue, lack of concentration, confusion and sleepiness along with anxiety, depression and irritability. Sleep deprivation can have serious consequences in professions like armed forces and medicine where quick decisions and actions need to be taken. Color-Word Stroop task is one of the reliable tests to assess attention and it analyzes the processing of information in two dimensions i.e., reading of words and naming of colour. The evidence regarding the effect of sleep deprivation on Stroop interference is conflicting. The present study evaluated the effect of 24 hours of sleep deprivation on reaction time and interference in Stroop task. Materials and Methods: The present study was done on 30 healthy male medical student volunteers in the age group of 18-25 years after taking their consent and clearance from Institute Ethics Committee. Recordings of Stroop task were at three times: baseline (between 7-9 am), after 12 hours (7-9 pm) and after 24 hours (7-9 am, next day). The subjects were allowed to perform normal daily activities. Results: The study revealed a significant increase in reaction time after 24 hours of sleep deprivation in comparison to baseline and after 12 hours of sleep deprivation. There was no significant change in interference and facilitation after sleep deprivation in comparison to baseline. The number of errors also did not show any significant change after sleep deprivation. Conclusion: The study indicated that there was slowing of responses without change in executive functions after 24 hours of sleep deprivation. It is probable that 24 hours of sleep deprivation does not bring about change in areas of brain affecting executive functions in healthy individuals who have normal sleep cycle. The present study indicated that in professions like armed forces and medicine working 24 hours at a stretch can lead to decrease in motor responses

  19. Sex differences in 24-hour ultra-marathon performance - A retrospective data analysis from 1977 to 2012

    PubMed Central

    Peter, Laura; Rüst, Christoph Alexander; Knechtle, Beat; Rosemann, Thomas; Lepers, Romuald

    2014-01-01

    OBJECTIVES: This study examined the changes in running performance and the sex differences between women and men in 24-hour ultra-marathons held worldwide from 1977 to 2012. METHOD: Changes in running speed and ages of the fastest 24-hour ultra-marathoners were determined using single- and multi-level regression analyses. RESULTS: From 1977 to 2012, the sex differences in 24-hour ultra-marathon performance were 4.6±0.5% for all women and men, 13.3% for the annual fastest finishers, 12.9±0.8% for the top 10 and 12.2±0.4% for the top 100 finishers. Over time, the sex differences decreased for the annual fastest finishers to 17%, for the annual 10 fastest finishers to 11.3±2.2% and for the annual 100 fastest finishers to 14.2±1.8%. For the annual fastest men, the age of peak running speed increased from 23 years (1977) to 53 years (2012). For the annual 10 and 100 fastest men, the ages of peak running speed were unchanged at 40.9±2.5 and 44.4±1.1 years, respectively. For women, the ages of the annual fastest, the annual 10 fastest and the annual 100 fastest remained unchanged at 43.0±6.1, 43.2±2.6 and 43.8±0.8 years, respectively. CONCLUSION: The gap between the annual top, annual top 10 and annual top 100 female and male 24-hour ultra-marathoners decreased over the last 35 years; however, it seems unlikely that women will outrun men in 24-hour ultra-marathons in the near future. The fastest 24-hour ultra-marathoners worldwide achieved their peak performance at the age of master athletes (>35 years). PMID:24473558

  20. Circadian (about 24-hour) variation in malondialdehyde content and catalase activity of mouse erythrocytes.

    PubMed

    Sani, Mamane; Sebai, Hichem; Ghanem-Boughanmi, Néziha; Boughattas, Naceur A; Ben-Attia, Mossadok

    2015-01-01

    Lipid peroxidation is a part of normal metabolism that may cause biological molecule damage leading to the formation of several specific metabolites that include aldehydes of variable chains, such as malondialdehyde (MDA). These biological effects are controlled in vivo by a wide spectrum of enzymatic and non-enzymatic defense mechanisms among which catalase (CAT) is considered as an important regulator of oxidative stress. The present study aimed to investigate the possible relationship between the temporal patterns of the formation of MDA and the activity of CAT in the erythrocytes of mice. Twenty-four-hour studies were performed on male Swiss albino mice, 12 weeks old, synchronized to a 12:12 light: dark cycle for 3 weeks. Different and comparable groups of animals (n = 10) were sacrificed at an interval of 4 hours (1, 5, 9, 13, 17, and 21 hours after light onset (HALO)). The levels of erythrocyte MDA concentration and CAT activity both significantly (analysis of variance: F = 6.4, P < 0.002) varied according to the time of sampling under non-stressed conditions. The characteristics of the waveform describing the temporal patterns differed between the two studied variables, e.g. MDA content showing one peak (≅21 HALO) and CAT activity showing three peaks (≅9, 17, and 21 HALO). Cosinor analysis revealed a significant (adjusted Cosinor: P ≤ 0.018) circadian (τ ≅ 24 hours) rhythm in MDA level and no statistically significant rhythmicity in CAT activity. The differences and the absence of correlation between the curve patterns of erythrocyte MDA content and CAT activity under physiological conditions are hypothesized to explain that variation in lipid peroxidation may depend on several factors. Moreover, the identification of peak/trough levels of MDA accumulation in erythrocytes may reflect the degree of oxidative stress in these blood cells. In addition, the observed significant time-of-day effect suggests that, in both clinical and scientific

  1. Characterisation of sleep in intensive care using 24-hour polysomnography: an observational study

    PubMed Central

    2013-01-01

    Introduction Many intensive care patients experience sleep disruption potentially related to noise, light and treatment interventions. The purpose of this study was to characterise, in terms of quantity and quality, the sleep of intensive care patients, taking into account the impact of environmental factors. Methods This observational study was conducted in the adult ICU of a tertiary referral hospital in Australia, enrolling 57 patients. Polysomnography (PSG) was performed over a 24-hour period to assess the quantity (total sleep time: hh:mm) and quality (percentage per stage, duration of sleep episode) of patients' sleep while in ICU. Rechtschaffen and Kales criteria were used to categorise sleep. Interrater checks were performed. Sound pressure and illuminance levels and care events were simultaneously recorded. Patients reported on their sleep quality in ICU using the Richards Campbell Sleep Questionnaire and the Sleep in Intensive Care Questionnaire. Data were summarised using frequencies and proportions or measures of central tendency and dispersion as appropriate and Cohen's Kappa statistic was used for interrater reliability of the sleep data analysis. Results Patients' median total sleep time was 05:00 (IQR: 02:52 to 07:14). The majority of sleep was stage 1 and 2 (medians: 19 and 73%) with scant slow wave and REM sleep. The median duration of sleep without waking was 00:03. Sound levels were high (mean Leq 53.95 dB(A) during the day and 50.20 dB(A) at night) and illuminance levels were appropriate at night (median <2 lux) but low during the day (median: 74.20 lux). There was a median 1.7 care events/h. Patients' mean self-reported sleep quality was poor. Interrater reliability of sleep staging was highest for slow wave sleep and lowest for stage 1 sleep. Conclusions The quantity and quality of sleep in intensive care patients are poor and may be related to noise, critical illness itself and treatment events that disturb sleep. The study highlights the

  2. Effects of dietary interventions on 24-hour urine parameters in patients with idiopathic recurrent calcium oxalate stones.

    PubMed

    Kıraç, Mustafa; Küpeli, Bora; Irkilata, Lokman; Gülbahar, Ozlem; Aksakal, Nur; Karaoğlan, Ustünol; Bozkırlı, Ibrahim

    2013-02-01

    The aim of this study is to investigate the effects of dietary factors on 24-hour urine parameters in patients with idiopathic recurrent calcium oxalate stones. A total of 108 of idiopathic recurrent calcium oxalate stones were included in the study. A 24-hour urinalysis was performed and metabolic abnormalities were measured for all of the patients. All of the patients were given specialized diets for their 24-hour urine abnormalities. At the end of first month, the same parameters were examined in another 24-hour urinalysis. Hyperoxaluria, hypernatruria, and hypercalciuria were found in 84 (77%), 43 (39.8%), and 38 (35.5%) of the patients, respectively. The differences between the oxalate, sodium, volume, uric acid, and citrate parameters before and after the dietary intervention were significant (p < 0.05). The calcium parameters were not significantly different before and after the intervention. We found that oxalate, sodium, volume, uric acid, and citrate-but not calcium-abnormalities in patients with recurrent calcium oxalate stones can be corrected by diet. The metabolic profiles of idiopathic calcium oxalate stone patients should be evaluated and the appropriate dietary interventions should be implemented to decrease stone recurrence.

  3. Self-Renewal and Differentiation Capacity of Urine-Derived Stem Cells after Urine Preservation for 24 Hours

    PubMed Central

    Shi, Yingai; Bharadwaj, Shantaram; Leng, Xiaoyan; Zhou, Xiaobo; Liu, Hong; Atala, Anthony; Zhang, Yuanyuan

    2013-01-01

    Despite successful approaches to preserve organs, tissues, and isolated cells, the maintenance of stem cell viability and function in body fluids during storage for cell distribution and transportation remains unexplored. The aim of this study was to characterize urine-derived stem cells (USCs) after optimal preservation of urine specimens for up to 24 hours. A total of 415 urine specimens were collected from 12 healthy men (age range 20–54 years old). About 6×104 cells shed off from the urinary tract system in 24 hours. At least 100 USC clones were obtained from the stored urine specimens after 24 hours and maintained similar biological features to fresh USCs. The stored USCs had a “rice grain” shape in primary culture, and expressed mesenchymal stem cell surface markers, high telomerase activity, and normal karyotypes. Importantly, the preserved cells retained bipotent differentiation capacity. Differentiated USCs expressed myogenic specific proteins and contractile function when exposed to myogenic differentiation medium, and they expressed urothelial cell-specific markers and barrier function when exposed to urothelial differentiation medium. These data demonstrated that up to 75% of fresh USCs can be safely persevered in urine for 24 hours and that these cells stored in urine retain their original stem cell properties, indicating that preserved USCs could be available for potential use in cell-based therapy or clinical diagnosis. PMID:23349776

  4. Estimation of Daily Sodium and Potassium Excretion Using Spot Urine and 24-Hour Urine Samples in a Black Population (Benin).

    PubMed

    Mizéhoun-Adissoda, Carmelle; Houehanou, Corine; Chianéa, Thierry; Dalmay, François; Bigot, André; Preux, Pierre-Marie; Bovet, Pascal; Houinato, Dismand; Desport, Jean-Claude

    2016-07-01

    The 24-hour urine collection method is considered the gold standard for the estimation of ingested potassium and sodium. Because of the impracticalities of collecting all urine over a 24-hour period, spot urine is often used for epidemiological investigations. This study aims to assess the agreement between spot urine and 24-hour urine measurements to determine sodium and potassium intake. A total of 402 participants aged 25 to 64 years were randomly selected in South Benin. Spot urine was taken during the second urination of the day. Twenty-four-hour urine was also collected. Samples (2-mL) were taken and then stored at -20°C. The analysis was carried out using potentiometric dosage. The agreement between spot urine and 24-hour urine measurements was established using Bland-Altman plots. A total of 354 results were analyzed. Daily sodium chloride and potassium chloride urinary excretion means were 10.2±4.9 g/24 h and 2.9±1.4 g/24 h, respectively. Estimated daily sodium chloride and potassium chloride means from the spot urine were 10.7±7.0 g/24 h and 3.9±2.1 g/24 h, respectively. Concordance coefficients were 0.61 at d=-0.5 g, (d±2SD=-11 g and 10.1 g) for sodium chloride and 0.61 at d=-1 g, (d±2SD=-3.8 g and 1.8 g) for potassium chloride. Spot urine method is acceptable for estimating 24-hour urinary sodium and potassium excretion to assess sodium and potassium intake in a black population. However, the confidence interval for the mean difference, which is too large, makes the sodium chloride results inadmissible at a clinical level.

  5. Value of 24-hour Delayed Film of Barium Enema for Evaluation of Colon Transit Function in Young Children with Constipation

    PubMed Central

    Yoo, Ha Yeong; Son, Jae Sung; Park, Hye Won; Kwak, Byung Ok; Kim, Hyeong Su; Bae, Sun Hwan

    2016-01-01

    Background/Aims A colon transit time test using radio-opaque markers (CTTRM) is considered the gold standard for evaluating colon transit function. A 24-hour delayed film of barium enema (BE) has been used as a supplementary method in structural evaluations. The aim of this study was to evaluate the utility of a 24-hour delayed BE film for assessing colon transit function in young children with constipation. Methods In total, 93 children with constipation who performed both single-contrast BE and CTTRM were enrolled in this study. Of these, the data from 70 children were analyzed (males 33, females 37; mean age [range], 5.63 ± 2.94 [2–14] years). The basic principle of the study is “velocity = distance/time”. Time values were identified in both studies, and the colon length and distance of barium movement were measured on the 24-hour delayed BE film. Thus, colon transit velocity values could be calculated using both methods. The correlation between colon transit velocity using a 24-hour delayed BE film versus CTTRM was analyzed statistically. Results Median value (interquartile range) of colon transit velocity using CTTRM was 1.57 (1.07–2.89) cm/hr, and that using BE of that was 1.58 (0.94–2.07) cm/hr. The Spearman correlation coefficient was 0.438 (P < 0.001) for the overall group. The correlation was strongest in children younger than 4 years (r = 0.537, P = 0.032). Conclusions Although the correlation between BE and CTTRM was not very strong, the 24-hour delayed BE film could provide broad information about colon transit function in young children, especially those under 4 years who usually cannot undergo CTTRM. PMID:26979249

  6. Microleakage of Two Self-Adhesive Cements in the Enamel and Dentin After 24 Hours and Two Months

    PubMed Central

    Jaberi Ansari, Zahra; Kalantar Motamedi, Mojdeh

    2014-01-01

    Objective: Microleakage is a main cause of restorative treatment failure. In this study, we compared occlusal and cervical microleakage of two self-adhesive cements after 24 hours and two months. Materials and Methods: In this in-vitro experimental study, class II inlay cavities were prepared on 60 sound human third molars. Composite inlays were fabricated with Z100 composite resin. The teeth were randomly assigned to six groups. RelyX-Arc (control), RelyX-Unicem and Maxcem were used for the first three groups and specimens were stored in distilled water at 37°C for 24 hours. The same cements were used for the remaining three groups, but the specimens were stored for 2 months. The teeth were subjected to 500 thermal cycles (5°C and 55°C) and immersed in 0.5% basic fuchsin for 24 hours and then sectioned mesiodistally and dye penetration was evaluated in a class II cavity with occlusal and cervical margins using X20 magnification stereomicroscope. Data were analyzed using Kruskal Wallis and Mann-Whitney U tests. Results: After 24 hours, cements had significant differences only in cervical margin microleakage (P=0.0001) and microleakage of RelyX-Unicem and Maxcem was significantly more than that of RelyX-Arc (both P=0.0001). Cervical microleakage in RelyX-Unicem and Maxcem was greater than occlusal (P=0.0001 and P=0.001, respectively). Microleakage was not significantly different between the occlusal and cervical margins after 2 months. Conclusion: Cervical microleakage was greater than occlusal in RelyX-Unicem and Maxcem after 24h. The greatest microleakage was reported for the cervical margin of RelyX-Unicem after 24 hours. PMID:25584053

  7. Changes in platelet morphology and function during 24 hours of storage.

    PubMed

    Braune, S; Walter, M; Schulze, F; Lendlein, A; Jung, F

    2014-01-01

    aggregates could be visualized microscopically. After four hours, first debris and very small aggregates occurred. After 24 hours, platelet aggregates and also debris progressively increased. In accordance to this, the CASY system revealed an increase of platelet aggregates (up to 90 μm diameter) with increasing storage time. The percentage of CD62P positive platelets and PF4 increased significantly with storage time in resting PRP. When soluble ADP was added to stored PRP samples, the number of activatable platelets decreased significantly over storage time. The present study reveals the importance of a consequent standardization in the preparation of WB and PRP. Platelet morphology and function, particularly platelet reactivity to adherent or soluble agonists in their surrounding milieu, changed rapidly outside the vascular system. This knowledge is of crucial interest, particularly in the field of biomaterial development for cardiovascular applications, and may help to define common standards in the in vitro hemocompatibility testing of biomaterials.

  8. Perfusion-CT - Can We Predict Acute Pancreatitis Outcome within the First 24 Hours from the Onset of Symptoms?

    PubMed Central

    Pieńkowska, Joanna; Gwoździewicz, Katarzyna; Skrobisz-Balandowska, Katarzyna; Marek, Iwona; Kostro, Justyna; Szurowska, Edyta; Studniarek, Michał

    2016-01-01

    Purpose Severe acute pancreatitis (AP) is still a significant clinical problem which is associated with a highly mortality. The aim of this study was the evaluation of prognostic value of CT regional perfusion measurement performed on the first day of onset of symptoms of AP, in assessing the risk of developing severe form of acute pancreatitis. Material and Methods 79 patients with clinical symptoms and biochemical criteria indicative of acute pancreatitis (acute upper abdominal pain, elevated levels of serum amylase and lipase) underwent perfusion CT within 24 hours after onset of symptoms. The follow-up examinations were performed after 4–6 days to detect progression of the disease. Perfusion parameters were compared in 41 people who developed severe form of AP (pancreatic and/or peripancreatic tissue necrosis) with parameters in 38 consecutive patients in whom course of AP was mild. Blood flow, blood volume, mean transit time and permeability surface area product were calculated in the three anatomic pancreatic subdivisions (head, body and tail). At the same time the patient's clinical status was assessed by APACHE II score and laboratory parameters such as CRP, serum lipase and amylase, AST, ALT, GGT, ALP and bilirubin were compared. Results Statistical differences in the perfusion parameters between the group of patients with mild and severe AP were shown. Blood flow, blood volume and mean transit time were significantly lower and permeability surface area product was significantly higher in patients who develop severe acute pancreatitis and presence of pancreatic and/or peripancreatic necrosis due to pancreatic ischemia. There were no statistically significant differences between the two groups in terms of evaluated on admission severity of pancreatitis assessed using APACHE II score and laboratory tests. Conclusions CT perfusion is a very useful indicator for prediction and selection patients in early stages of acute pancreatitis who are at risk of

  9. HOW RELIABLE IS 24 HOUR SERUM LITHIUM LEVEL AFTER A TEST DOSE OF LITHIUM IN PREDICTING OPTIMAL LITHIUM DOSE?

    PubMed Central

    Kuruvilla, K.; Shaji, K.S.

    1989-01-01

    SUMMARY 57% of a group of 35 patients treated with Lithium Carbonate at dosages predicted by the nomogram suggested by Cooper et al (1973) failed to reach therapeutic levels of serum lithium. This finding casts serious doubts on the usefulness of the claim by Cooper et al (1973 & 1976) that 24 hour serum lithium level after a test dose of 600 mg. lithium can predict the daily lithium dose. PMID:21927360

  10. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

    PubMed Central

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. Results A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Conclusions Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. PMID:27286119

  11. Increased energy density of the home-delivered lunch meal improves 24-hour nutrient intakes in older adults.

    PubMed

    Silver, Heidi J; Dietrich, Mary S; Castellanos, Victoria H

    2008-12-01

    As food intake declines with aging, older adults develop energy and nutrient inadequacies. It is important to design practical approaches to combat insufficient dietary intakes to decrease risk for acute and chronic diseases, illness, and injury. Manipulating the energy density of meals has improved energy intakes in institutional settings, but the effects on community-residing older adults who are at nutrition risk have not been investigated. The aim of this study was to determine whether enhancing the energy density of food items regularly served in a home-delivered meals program would increase lunch and 24-hour energy and nutrient intakes. In a randomized crossover counterbalanced design, 45 older adult Older American Act Nutrition Program participants received a regular and enhanced version of a lunch meal on alternate weeks. The types of foods, portion sizes (gram weight), and appearance of the lunch meal was held constant. Consumption of the enhanced meal increased average lunch energy intakes by 86% (P<0.001) and 24-hour energy intakes by 453 kcal (from 1,423.1+/-62.2 to 1,876.2+/-78.3 kcal, P<0.001). The 24-hour intakes of several key macronutrients and micronutrients also improved. These data suggest that altering the energy density of regularly served menu items is an effective strategy to improve dietary intakes of free-living older adults.

  12. Assessment of 24-hours Aldosterone Administration on Protein Abundances in Fluorescence-Sorted Mouse Distal Renal Tubules by Mass Spectrometry

    PubMed Central

    Jensen, Thomas B; Pisitkun, Trairak; Hoffert, Jason D; Jensen, Uffe B; Fenton, Robert A; Praetorius, Helle A; Knepper, Mark A; Praetorius, Jeppe

    2013-01-01

    Background/Aims Aldosterone exerts multiple long-term effects in the distal renal tubules. The aim of this study was to establish a method for identifying proteins in these tubules that change in abundance by only 24-hours aldosterone administration. Methods Mice endogenously expressing green fluorescent protein (eGFP) in the connecting tubule and cortical collecting ducts were treated with a subcutaneous injection of 2.0 mg/kg aldosterone or vehicle (n=5), and sacrificed 24 hours later. Suspensions of single cells were obtained enzymatically, and eGFP positive cells were isolated by fluorescence activated cell sorting (FACS). Samples of 100 μg proteins were digested with trypsin and labeled with 8-plex iTRAQ reagents and processed for liquid chromatography tandem mass spectrometry (LC-MS/MS). Results FACS yielded 1.4 million cells per mouse. The LC-MS/MS spectra were matched to peptides by the SEQUEST search algorithm, which identified 3002 peptides corresponding to 506 unique proteins of which 20 significantly changed abundance 24-hours after aldosterone injection. Conclusion We find the method suitable and useful for studying hormonal effects on protein abundance in distal tubular segments. PMID:23428628

  13. Prognostic factors for death and survival with or without complications in cardiac arrest patients receiving CPR within 24 hours of anesthesia for emergency surgery

    PubMed Central

    Siriphuwanun, Visith; Punjasawadwong, Yodying; Lapisatepun, Worawut; Charuluxananan, Somrat; Uerpairojkit, Ketchada

    2014-01-01

    than or equal to 65 years of age (OR =4.30, 95% CI =1.13–16.42), upper abdominal site of surgery (OR =10.86, 95% CI =1.99–59.13), shock prior to cardiac arrest (OR =3.62, 95% CI =1.30–10.12), arrhythmia prior to cardiac arrest (OR =4.61, 95% CI =1.01–21.13), and cardiac arrest occurring in the postoperative period (OR =3.63, 95% CI =1.31–10.02). Conclusion The mortality and morbidity in patients who received anesthesia for emergency surgery within 24 hours of their first CPR were high, and were associated with identifiable patient comorbidity, age, shock, anatomic site of operation, the timing of cardiac arrest, EKG rhythm, and the duration of CPR. EKG monitoring helps to identify cardiac arrest quickly and diagnose the EKG rhythm as a shockable or nonshockable rhythm, with CPR being performed as per the American Heart Association (AHA) CPR Guidelines 2010. The use of the fast track system in combination with an interdisciplinary team for surgery, CPR, and postoperative care helps to rescue patients in a short time. PMID:25378961

  14. Measuring residual renal function in dialysis patients: can we dispense with 24-hour urine collections?

    PubMed

    Davenport, Andrew

    2016-05-01

    Residual renal function is associated with improved survival and quality of life for dialysis patients. Whereas residual renal function is monitored in peritoneal dialysis patients, many hemodialysis centers simply concentrate on achieving dialyzer urea clearance targets. Accurately quantifying residual renal function from urine collections is arduous. Thus, there is a clinical need to develop alternative methods of assessing residual renal function based on serum testing, especially for patients receiving less than thrice weekly dialysis.

  15. Electrophysiology study without intracardiac catheters. The value of proper Holter interpretation: a case report.

    PubMed

    Enriquez, Andres; Bittner, Alex; Almehairi, Mohammed; Baranchuk, Adrian

    2014-01-01

    This case report presents the case of a 55-year-old male patient with a long-standing history of palpitations. A 24-h Holter monitor revealed an incessant form of long-RP supraventricular tachycardia. The differential diagnosis is presented and discussed. In a stepwise approach, it is explained how the exact mechanism of the tachycardia can be inferred through careful examination of the multiple onsets, terminations and response to spontaneous monomorphic premature ventricular contractions.

  16. Association of target organ damage with 24-hour systolic and diastolic blood pressure levels and hypertension subtypes in untreated Chinese.

    PubMed

    Wei, Fang-Fei; Li, Yan; Zhang, Lu; Xu, Ting-Yan; Ding, Feng-Hua; Staessen, Jan A; Wang, Ji-Guang

    2014-02-01

    The association of target organ damage with 24-hour systolic and diastolic blood pressure levels and ambulatory hypertension subtypes has not yet been examined in untreated Chinese patients. We measured left ventricular mass index by echocardiography (n=619), the urinary albumin:creatinine ratio (n=1047), and aortic pulse wave velocity by tonometry (n=1013) in 1047 untreated subjects (mean age, 50.6 years; 48.9% women). Normotension was a 24-hour systolic/diastolic blood pressure <130/<80 mm Hg. Hypertension subtypes were isolated diastolic hypertension and mixed systolic plus diastolic hypertension. We assessed associations of interest by multivariable-adjusted linear models. Using normotension as reference, mixed hypertension was associated with higher (P≤0.003) left ventricular mass index (+4.31 g/m(2)), urinary albumin:creatinine ratio (+1.63 mg/mmol), and pulse wave velocity (+0.76 m/s); and isolated diastolic hypertension was associated with similar left ventricular mass index and pulse wave velocity (P≥0.39), but higher urinary albumin:creatinine ratio (+1.24 mg/mmol; P=0.002). In younger participants (<55 years), the mutually independent effect sizes associated with 1 SD increases in 24-hour systolic/diastolic blood pressure were +3.31/-0.36 g/m(2) (P=0.009/0.79) for left ventricular mass index, +1.15/+1.14 mg/mmol (P=0.02/0.04) for the urinary albumin:creatinine ratio, and +0.54/-0.05 m/s (P<0.001/0.54) for pulse wave velocity. In older participants, these estimates were +3.58/+0.30 g/m(2) (P=0.045/0.88), +1.23/+1.05 mg/mmol (P=0.002/0.54), and +0.76/-0.49 m/s (P<0.001/<0.001), respectively. In conclusion, 24-hour systolic blood pressure and mixed hypertension are major determinants of target organ damage irrespective of age and target organ, whereas 24-hour diastolic blood pressure and isolated diastolic hypertension only relate to the urinary albumin:creatinine ratio below middle age.

  17. 24-hour control of body temperature in rats. I. Integration of behavioral and autonomic effectors.

    PubMed

    Gordon, C J

    1994-07-01

    Some studies suggest that the nocturnal elevation in core temperature (Tc) of the rat is mediated by an elevation in the set point. The role of set point can be assessed if behavioral effectors are measured simultaneously with other thermoregulatory effectors and Tc over a 24-h period. Selected ambient temperature (STa) and motor activity (MA) were measured in rats housed in a temperature gradient system with a 12:12-h photoperiod (lights on 0600 h). Tc and heart rate (HR) were monitored by telemetry. During the light phase, STa, Tc, HR, and MA were relatively stable with values 29.0 degrees C, 37.1 degrees C, 310 beats/min, and 1-2 m/h, respectively. During the light-to-dark transition there were abrupt elevations in Tc, HR, and MA but no change in STa. STa decreased during the dark phase and reached a nadir of 23 degrees C at 0500 h. All variables recovered to basal levels within 3-4 h after the onset of the light phase. Overall, autonomic effectors control the elevation in Tc during the onset of the dark phase while behavioral effectors have little if any role. Behavioral thermoregulation is important in two ways: 1) the selection of cooler Ta values at night to prevent an excess elevation in Tc and 2) a preference for cooler Ta values before the light phase to facilitate the recovery of Tc. PMID:8048648

  18. Electronic Dietary Intake Assessment (e-DIA): Comparison of a Mobile Phone Digital Entry App for Dietary Data Collection With 24-Hour Dietary Recalls

    PubMed Central

    O'Connor, Sarah; Giannelli, Valentina; Yap, Megan LH; Tang, Lie Ming; Roy, Rajshri; Louie, Jimmy Chun Yu; Hebden, Lana; Kay, Judy; Allman-Farinelli, Margaret

    2015-01-01

    Background The electronic Dietary Intake Assessment (e-DIA), a digital entry food record mobile phone app, was developed to measure energy and nutrient intake prospectively. This can be used in monitoring population intakes or intervention studies in young adults. Objective The objective was to assess the relative validity of e-DIA as a dietary assessment tool for energy and nutrient intakes using the 24-hour dietary recall as a reference method. Methods University students aged 19 to 24 years recorded their food and drink intake on the e-DIA for five days consecutively and completed 24-hour dietary recalls on three random days during this 5-day study period. Mean differences in energy, macro-, and micronutrient intakes were evaluated between the methods using paired t tests or Wilcoxon signed-rank tests, and correlation coefficients were calculated on unadjusted, energy-adjusted, and deattenuated values. Bland-Altman plots and cross-classification into quartiles were used to assess agreement between the two methods. Results Eighty participants completed the study (38% male). No significant differences were found between the two methods for mean intakes of energy or nutrients. Deattenuated correlation coefficients ranged from 0.55 to 0.79 (mean 0.68). Bland-Altman plots showed wide limits of agreement between the methods but without obvious bias. Cross-classification into same or adjacent quartiles ranged from 75% to 93% (mean 85%). Conclusions The e-DIA shows potential as a dietary intake assessment tool at a group level with good ranking agreement for energy and all nutrients. PMID:26508282

  19. Meal-induced 24-hour profile of circulating glycated insulin in type 2 diabetic subjects measured by a novel radioimmunoassay.

    PubMed

    Lindsay, John R; McKillop, Aine M; Mooney, Mark H; Flatt, Peter R; Bell, Patrick M; O'harte, Finbarr P M

    2003-05-01

    Increasing evidence supports a role for glycated insulin in the insulin-resistant state of type 2 diabetes. We measured 24-hour profiles of plasma glycated insulin, using a novel radioimmunoassay (RIA), to evaluate the effects of meal stimulation and intermittent fasting on circulating concentrations of plasma glycated insulin in type 2 diabetes. Patients (n = 6; hemoglobin A(1c) [HbA(1c)], 7.2% +/- 0.6%; fasting plasma glucose, 7.4 +/- 0.7 mmol/L; body mass index [BMI], 35.7 +/- 3.5 kg/m(2); age, 56.3 +/- 4.4 years) were admitted for 24 hours and received a standardized meal regimen. Half-hourly venous samples were taken for plasma glycated insulin, glucose, insulin, and C-peptide concentrations between 8 am and midnight and 2-hourly overnight. The mean plasma glycated insulin concentration over 24 hours was 27.8 +/- 1.2 pmol/L with a mean ratio of insulin:glycated insulin of 11:1. Circulating glucose, insulin, C-peptide, and glycated insulin followed a basal and meal-related pattern with most prominent increments following breakfast, lunch, and evening meal, respectively. The mean concentrations of glycated insulin during the morning, afternoon, evening, and night-time periods were 24.4 +/- 2.5, 28.7 +/- 2.3, 31.1 +/- 2.1, and 26.2 +/- 1.5 pmol/L, respectively, giving significantly higher molar ratios of insulin:glycated insulin of 18.0:1, 14.2:1, and 12.7:1 compared with 7.0:1 at night (P <.01 to P <.001). These data demonstrate that glycated insulin circulates at relatively high concentrations in type 2 diabetes with a diurnal pattern of basal and meal-stimulated release. A higher proportion of glycated insulin circulates at night suggestive of differences in metabolic clearance compared with native insulin.

  20. Effects of Fibrinogen Concentrate on Thrombin Generation, Thromboelastometry Parameters, and Laboratory Coagulation Testing in a 24-Hour Porcine Trauma Model

    PubMed Central

    Zentai, Christian; Solomon, Cristina; van der Meijden, Paola E. J.; Spronk, Henri M. H.; Schnabel, Jonas; Rossaint, Rolf

    2015-01-01

    Introduction: In a 24-hour porcine model of liver injury, we showed that fibrinogen supplementation does not downregulate endogenous fibrinogen synthesis. Here we report data from the same study showing the impact of fibrinogen on coagulation variables. Materials and Methods: Coagulopathy was induced in 20 German land race pigs by hemodilution and blunt liver injury. Animals randomly received fibrinogen concentrate (100 mg/kg) or saline. Coagulation parameters were assessed and thromboelastometry (ROTEM) was performed. Results: Fibrinogen concentrate significantly reduced the prolongations of EXTEM clotting time, EXTEM clot formation time, and prothrombin time induced by hemodilution and liver injury. A decrease in clot strength was also ameliorated. Endogenous thrombin potential was significantly higher in the fibrinogen group than in the control group, 20 minutes (353 ± 24 vs 289 ± 22 nmol/L·min; P < .05) and 100 minutes (315 ± 40 vs 263 ± 38 nmol/L·min; P < .05) after the start of infusion. However, no significant between-group differences were seen in other thrombin generation parameters or in d-dimer or thrombin–antithrombin levels. Fibrinogen–platelet binding was reduced following liver injury, with no significant differences between groups. No significant between-group differences were observed in any parameter at ∼12 and ∼24 hours. Conclusion: This study suggests that, in trauma, fibrinogen supplementation may shorten some measurements of the speed of coagulation initiation and produce a short-lived increase in endogenous thrombin potential, potentially through increased clotting substrate availability. Approximately 12 and 24 hours after starting fibrinogen concentrate/saline infusion, all parameters measured in this study were comparable in the 2 study groups. PMID:25948634

  1. The Relationship Between 24-Hour Symptoms and COPD Exacerbations and Healthcare Resource Use: Results from an Observational Study (ASSESS).

    PubMed

    Miravitlles, Marc; Worth, Heinrich; Soler-Cataluña, Juan José; Price, David; De Benedetto, Fernando; Roche, Nicolas; Godtfredsen, Nina S; van der Molen, Thys; Löfdahl, Claes-Göran; Padullés, Laura; Ribera, Anna

    2016-10-01

    This observational study assessed the relationship between nighttime, early-morning and daytime chronic obstructive pulmonary disease (COPD) symptoms and exacerbations and healthcare resource use. COPD symptoms were assessed at baseline in patients with stable COPD using a standardised questionnaire during routine clinical visits. Information was recorded on exacerbations and healthcare resource use during the year before baseline and during a 6-month follow-up period. The main objective of the analysis was to determine the predictive nature of current symptoms for future exacerbations and healthcare resource use. 727 patients were eligible (65.8% male, mean age: 67.2 years, % predicted forced expiratory volume in 1 second: 52.8%); 698 patients (96.0%) provided information after 6 months. Symptoms in any part of the day were associated with a prior history of exacerbations (all p < 0.05) and nighttime and early-morning symptoms were associated with the frequency of primary care visits in the year before baseline (both p < 0.01). During follow-up, patients with baseline symptoms during any part of the 24-hour day had more exacerbations than patients with no symptoms in each period (all p < 0.05); there was also an association between 24-hour symptoms and the frequency of primary care visits (all p ≤ 0.01). Although there was a significant association between early-morning and daytime symptoms and exacerbations during follow-up (both p < 0.01), significance was not maintained when adjusted for potential confounders. Prior exacerbations were most strongly associated with future risk of exacerbation. The results suggest 24-hour COPD symptoms do not independently predict future exacerbation risk.

  2. Developing a Method to Test the Validity of 24 Hour Time Use Diaries Using Wearable Cameras: A Feasibility Pilot

    PubMed Central

    Kelly, Paul; Thomas, Emma; Doherty, Aiden; Harms, Teresa; Burke, Órlaith; Gershuny, Jonathan; Foster, Charlie

    2015-01-01

    Self-report time use diaries collect a continuous sequenced record of daily activities but the validity of the data they produce is uncertain. This study tests the feasibility of using wearable cameras to generate, through image prompted interview, reconstructed 'near-objective' data to assess their validity. 16 volunteers completed the Harmonised European Time Use Survey (HETUS) diary and used an Autographer wearable camera (recording images at approximately 15 second intervals) for the waking hours of the same 24-hour period. Participants then completed an interview in which visual images were used as prompts to reconstruct a record of activities for comparison with the diary record. 14 participants complied with the full collection protocol. We compared time use and number of discrete activities from the diary and camera records (using 10 classifications of activity). In terms of aggregate totals of daily time use we found no significant difference between the diary and camera data. In terms of number of discrete activities, participants reported a mean of 19.2 activities per day in the diaries, while image prompted interviews revealed 41.1 activities per day. The visualisations of the individual activity sequences reveal some potentially important differences between the two record types, which will be explored at the next project stage. This study demonstrates the feasibility of using wearable cameras to reconstruct time use through image prompted interview in order to test the concurrent validity of 24-hour activity time-use budgets. In future we need a suitably powered study to assess the validity and reliability of 24-hour time use diaries. PMID:26633807

  3. The Automated Self-Administered 24-Hour Dietary Recall for Children, 2012 version, for youth aged 9 to 11 Years: A validation study

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our objective was to validate the 2012 version of the Automated Self-Administered 24-Hour Dietary Recall for Children (ASA24-Kids-2012), a self-administered web-based 24-hour dietary recall (24hDR) instrument, among children aged 9 to 11 years, in two sites using a quasiexperimental design. In one s...

  4. A Plaque Disruption Index Identifies Patients with Non-STE-Type 1 Myocardial Infarction within 24 Hours of Troponin Positivity

    PubMed Central

    Al-Mohaissen, Maha A.; Carere, Ronald G.; Mancini, G. B. John; Humphries, Karin H.; Whalen, Beth A.; Lee, Terry; Scheuermeyer, Frank X.; Ignaszewski, Andrew P.

    2016-01-01

    Background Markers of plaque destabilization and disruption may have a role in identifying non-STE- type 1 Myocardial Infarction in patients presenting with troponin elevation. We hypothesized that a plaque disruption index (PDI) derived from multiple biomarkers and measured within 24 hours from the first detectable troponin in patients with acute non-STE- type 1 MI (NSTEMI-A) will confirm the diagnosis and identify these patients with higher specificity when compared to individual markers and coronary angiography. Methods We examined 4 biomarkers of plaque destabilization and disruption: myeloperoxidase (MPO), high-sensitivity interleukin-6, myeloid-related protein 8/14 (MRP8/14) and pregnancy-associated plasma protein-A (PAPP-A) in 83 consecutive patients in 4 groups: stable non-obstructive coronary artery disease (CAD), stable obstructive CAD, NSTEMI-A (enrolled within 24 hours of troponin positivity), and NSTEMI-L (Late presentation NSTEMI, enrolled beyond the 24 hour limit). The PDI was calculated and the patients’ coronary angiograms were reviewed for evidence of plaque disruption. The diagnostic performance of the PDI and angiography were compared. Results Compared to other biomarkers, MPO had the highest specificity (83%) for NSTEMI-A diagnosis (P<0.05). The PDI computed from PAPP-A, MRP8/14 and MPO was higher in NSTEMI-A patients compared to the other three groups (p<0.001) and had the highest diagnostic specificity (87%) with 79% sensitivity and 86% accuracy, which were higher compared to those obtained with MPO, but did not reach statistical significance (P>0.05 for all comparisons). The PDI had higher specificity and accuracy for NSTEMI-A diagnosis compared to coronary angiography (P<0.05). Conclusions A PDI measured within 24 hour of troponin positivity has potential to identify subjects with acute Non-ST-elevation type 1 MI. Additional evidence using other marker combinations and investigation in a sufficiently large non-selected cohort is warranted

  5. 24-Hour Forecasting of CME/Flare Eruptions from Active-Region Magnetograms (Invited)

    NASA Astrophysics Data System (ADS)

    Falconer, D. A.; Barghouty, A.; Khazanov, I. G.; Moore, R. L.

    2010-12-01

    We have developed an automated tool for forecasting severe space weather from full-disk magnetograms. This tool is now being used on a trial basis by NASA’s Space Radiation Analysis Group (SRAG) at JSC. SRAG is responsible for the monitoring and forecasting of exposure the astronauts to particle radiation. The tool is described in Falconer, Barghouty, Khazanov, and Moore (2010), submitted to Space Weather. The new software tool is designed for the empirical forecasting of M- and X-class flares, coronal mass ejections, and solar energetic particle events. For each of these event types, the algorithm is based on the empirical relationship between the event rate and a proxy of the active region’s free magnetic energy. The relationship is determined from ~40,000 active-region magnetograms from ~1,300 active regions that were observed within 30 heliographic degrees from disk center by SOHO/MDI, and that have known histories of flare, coronal mass ejection, and solar energetic particle event production during disk passage. The tool automatically extracts each strong-field magnetic areas from an MDI full-disk magnetogram, identifies each as a NOAA active region, and measures the proxy of the active region’s free magnetic energy from the extracted magnetogram. For each active region, the empirical relationship is then used to convert the free magnetic energy proxy into the active region’s expected event rate (see figure). The expected event rate in turn can be readily converted into the probability that the active region will produce such an event in a given forward time window. We can make this tool applicable to the full-disk line-of-sight magnetograms from SDO/HMI or as a backup, from NSO/GONG. By empirically determining the conversion of the value of free-energy proxy measured from an HMI magnetogram to that which would be measured from an MDI magnetogram, we can use the HMI magnetograms with the empirical relationships determined from our MDI data base to make

  6. Transcranial Direct Current Stimulation Augments Perceptual Sensitivity and 24-Hour Retention in a Complex Threat Detection Task

    PubMed Central

    Falcone, Brian; Coffman, Brian A.; Clark, Vincent P.; Parasuraman, Raja

    2012-01-01

    We have previously shown that transcranial direct current stimulation (tDCS) improved performance of a complex visual perceptual learning task (Clark et al. 2012). However, it is not known whether tDCS can enhance perceptual sensitivity independently of non-specific, arousal-linked changes in response bias, nor whether any such sensitivity benefit can be retained over time. We examined the influence of stimulation of the right inferior frontal cortex using tDCS on perceptual learning and retention in 37 healthy participants, using signal detection theory to distinguish effects on perceptual sensitivity (d′) from response bias (ß). Anodal stimulation with 2 mA increased d′, compared to a 0.1 mA sham stimulation control, with no effect on ß. On completion of training, participants in the active stimulation group had more than double the perceptual sensitivity of the control group. Furthermore, the performance enhancement was maintained for 24 hours. The results show that tDCS augments both skill acquisition and retention in a complex detection task and that the benefits are rooted in an improvement in sensitivity (d′), rather than changes in response bias (ß). Stimulation-driven acceleration of learning and its retention over 24 hours may result from increased activation of prefrontal cortical regions that provide top-down attentional control signals to object recognition areas. PMID:22511978

  7. Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

    NASA Technical Reports Server (NTRS)

    Engelke, K. A.; Shea, J. D.; Doerr, D. F.; Convertino, V. A.

    1992-01-01

    To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

  8. Transcranial direct current stimulation augments perceptual sensitivity and 24-hour retention in a complex threat detection task.

    PubMed

    Falcone, Brian; Coffman, Brian A; Clark, Vincent P; Parasuraman, Raja

    2012-01-01

    We have previously shown that transcranial direct current stimulation (tDCS) improved performance of a complex visual perceptual learning task (Clark et al. 2012). However, it is not known whether tDCS can enhance perceptual sensitivity independently of non-specific, arousal-linked changes in response bias, nor whether any such sensitivity benefit can be retained over time. We examined the influence of stimulation of the right inferior frontal cortex using tDCS on perceptual learning and retention in 37 healthy participants, using signal detection theory to distinguish effects on perceptual sensitivity (d') from response bias (ß). Anodal stimulation with 2 mA increased d', compared to a 0.1 mA sham stimulation control, with no effect on ß. On completion of training, participants in the active stimulation group had more than double the perceptual sensitivity of the control group. Furthermore, the performance enhancement was maintained for 24 hours. The results show that tDCS augments both skill acquisition and retention in a complex detection task and that the benefits are rooted in an improvement in sensitivity (d'), rather than changes in response bias (ß). Stimulation-driven acceleration of learning and its retention over 24 hours may result from increased activation of prefrontal cortical regions that provide top-down attentional control signals to object recognition areas.

  9. Comparison of Interviewer-Administered and Automated Self-Administered 24-Hour Dietary Recalls in 3 Diverse Integrated Health Systems.

    PubMed

    Thompson, Frances E; Dixit-Joshi, Sujata; Potischman, Nancy; Dodd, Kevin W; Kirkpatrick, Sharon I; Kushi, Lawrence H; Alexander, Gwen L; Coleman, Laura A; Zimmerman, Thea P; Sundaram, Maria E; Clancy, Heather A; Groesbeck, Michelle; Douglass, Deirdre; George, Stephanie M; Schap, TusaRebecca E; Subar, Amy F

    2015-06-15

    Twenty-four-hour dietary recalls provide high-quality intake data but have been prohibitively expensive for large epidemiologic studies. This study's goal was to assess whether the web-based Automated Self-Administered 24-Hour Recall (ASA24) performs similarly enough to the standard interviewer-administered, Automated Multiple-Pass Method (AMPM) 24-hour dietary recall to be considered a viable alternative. In 2010-2011, 1,081 adults from 3 integrated health systems in Detroit, Michigan; Marshfield, Wisconsin; and Kaiser-Permanente Northern California participated in a field trial. A quota design ensured a diverse sample by sex, age, and race/ethnicity. Each participant was asked to complete 2 recalls and was randomly assigned to 1 of 4 protocols differing by type of recall and administration order. For energy, the mean intakes were 2,425 versus 2,374 kcal for men and 1,876 versus 1,906 kcal for women by AMPM and ASA24, respectively. Of 20 nutrients/food groups analyzed and controlling for false discovery rate, 87% were judged equivalent at the 20% bound. ASA24 was preferred over AMPM by 70% of the respondents. Attrition was lower in the ASA24/AMPM study group than in the AMPM/ASA24 group, and it was lower in the ASA24/ASA24 group than in the AMPM/AMPM group. ASA24 offers the potential to collect high-quality dietary intake information at low cost with less attrition.

  10. 24-hour urine protein

    MedlinePlus

    ... a blockage of blood vessels, or other causes Multiple myeloma Healthy people may have higher than normal urine ... Distal Hemolytic anemia Macroglobulinemia of Waldenstrom Microalbuminuria test Multiple myeloma Nephrotic syndrome Proximal Wilson disease Update Date 11/ ...

  11. Urine 24-hour volume

    MedlinePlus

    ... in a day, such as: Creatinine Sodium Potassium Nitrogen Protein This test may also be done if ... disease Potassium urine test Sodium urine test Urea nitrogen urine test Urination - excessive amount Urine output - decreased ...

  12. Ultra-Rapid dUT1 Measurements on Japan-Fennoscandian Baselines - Application to 24-hour Sessions

    NASA Technical Reports Server (NTRS)

    Matsuzaka, Shigeru; Kurihara, Shinobu; Sekido, Mamoru; Hobiger, Thomas; Haas, Rudiger; Ritakari, Jouko; Wagner, Jan

    2010-01-01

    GSI, NICT, OSO, and MRO have been engaged in Ultra-rapid dUT1 experiments since 2007 aiming at the technological possibility of real-time dUT1 results using the e-VLBI technique. We have already successfully determined dUT1 in less than four minutes after the end of an experimental Intensive session in 2008, and at present we routinely get the results within 30 minutes for regular Intensives. In 2009 we applied the technique to 24-hour sessions and continuously obtained dUT1 values by processing and analyzing Tsukuba Onsala data in near real-time. It showed a detailed behavior of UT1 variations, which could be very valuable for scientific study as well as for precise prediction of UT1-UTC.

  13. Tolvaptan Prolongs Blockage of the Vasopressin Type II Receptor Over 24 Hours in Responders With Stage D Heart Failure.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Komuro, Issei

    2016-01-01

    The urine aquaporin-2 (U-AQP2) level relative to the plasma arginine vasopressin (P-AVP) level is a novel predictor of the responsiveness to the vasopressin type 2 receptor (V2R) antagonist tolvaptan (TLV). However, little has been reported about the concentration-time profile of U-AQP2 after TLV treatment. We evaluated 24 patients with decompensated stage D heart failure (HF) who had received 3.75 mg/day of TLV on a de novo basis for > 7 days to treat congestion refractory to conventional diuretics. Seventeen patients were TLV-responders, whose 24-hour urine volume (UV) increased after TLV initiation; the other 7 patients were TLV-non-responders. The U-AQP2 of the TLV-responders, corrected for the urine creatinine concentration, decreased significantly at 4 hours after TLV administration without returning to the day-1 morning level on the morning of day-7. The TLV-non-responder U-AQP2 levels remained low even before the TLV treatment. On the morning of day-7, the TLV-responder U-AQP2/P-AVP ratio was comparable to that of the TLV-non-responders. Among 18 patients (11 responders and 7 non-responders), the day-7 TLV trough concentration was 64 ± 62 ng/mL and was negatively correlated with the estimated glomerular filtration rate (eGFR). TLV has antagonistic effects on the V2R over 24 hours in TLV-responders with advanced heart failure and chronic kidney disease, probably due to persistently elevated blood TLV concentration. The unresponsiveness to TLV in the TLV-non-responders is not attributable to malabsorption. PMID:26742881

  14. Prognostic Value of the 24-Hour Neurological Examination in Anterior Circulation Ischemic Stroke: A post hoc Analysis of Two Randomized Controlled Stroke Trials

    PubMed Central

    Rangaraju, Srikant; Frankel, Michael; Jovin, Tudor G.

    2016-01-01

    Background Early prognostication of long-term outcomes following ischemic stroke can facilitate medical decision-making. We hypothesized that the 24-hour National Institute of Health Stroke Scale (NIHSS) predicts 3-month clinical outcomes in anterior circulation stroke. Methods Secondary analyses of the Interventional Management of Stroke 3 (IMS3) and intravenous tissue plasminogen activator (IV tPA) for acute ischemic stroke [National Institute of Neurological Diseases and Stroke (NINDS) IV tPA] trials were performed. In participants with documented 24-hour NIHSS and 3-month Modified Rankin Scale (mRS), the predictive power of the 24-hour NIHSS and 24-hour NIHSS improvement for 3-month outcomes [mRS 0-2 and Barthel Index (BI) ≥95] was assessed. Percentages of good outcome (mRS 0-2 or BI ≥95) at 3, 6, and 12 months and mean quality of life (EQ5D™) index at 3 months across 24-hour NIHSS quartiles were compared. Results The majority of the study participants were included (IMS3 n = 587/656, NINDS IV tPA n = 619/624). The 24-hour NIHSS was correlated with 3-month mRS (R = 0.73) with excellent predictive power for mRS 0-2 [area under the curve (AUC) = 0.91] and BI ≥95 (AUC = 0.9) in both cohorts. A model with the 24-hour NIHSS alone correctly classified 82-84% of patients in both cohorts. The percentages of good outcomes at 3-12 months across 24-hour NIHSS quartiles were similar in both cohorts. mRS 0-2 was achieved by 75.6-77.7% of patients with 24-hour NIHSS ≤11 but by only 1.4-3.6% with 24-hour NIHSS ≥20. The EQ5D index at 3 months varied among NIHSS 0-4 (mean 0.86 ± 0.16), 5-11 (0.77 ± 0.18), and 12-19 (0.59 ± 0.26) quartiles. Conclusions The 24-hour NIHSS strongly predicts long-term stroke outcomes and is associated with quality of life. Its easy availability, reliability, and validity support its use as an early prognostic marker and surrogate of clinical outcome in ischemic stroke. PMID:27051408

  15. A comparison of regression and Bayesian change point analysis for extreme 24hours rainfall in South Australia

    NASA Astrophysics Data System (ADS)

    Kamruzzaman, M.; Beecham, S.; Metcalfe, A.

    2013-12-01

    We consider monthly extremes rainfall, aggregated over 24 hours, at 24 rainfall station in South Australia (SA). A self-organizing map (SOM) technique is used to draw contours of extreme for this area for each month. The possibility of change in extreme rainfall is investigated in two ways. The first is a multiple regression with time, month, station and their interaction as predictor variables. A confidence interval and for the linear and quadratic effects of time series are given. We have developed a strategy to possible improve prediction of extreme rainfall as a linear combination of original prediction. The dramatic improvement is a consequence of introducing squares and cross product of predictor variables is given in calibration, validation and re-calibration model. The similarity between fitted to the calibration and validation periods suggests that the hydrological process have been relatively stable over the period. The modeling strategy is empirical and will valid for different time period; although, in general, estimated coefficients could change substantially. The second analysis is a Bayesian change's point (BCP) analysis based on deseasonalised extreme data. A univariate BCP is applied in the data averaged over stations and compared with a multivariate BCP applied to the individual station records. The BCP is applied to investigate the possibility of sudden change rather than a smooth trend.

  16. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome.

    PubMed

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support. PMID:27398166

  17. Adrenal catecholamine synthesis rate changes induced by combined thermal and immobilization stress in fed and 24 hour fasted rats.

    PubMed

    Bargiel, Z; Nowicka, H

    1989-01-01

    The combined stress of acute immobilization (IM) at high and low ambient temperature has been used to determine its influence on adrenal catecholamine (CA) content assassed histofluorimetrically in fed and 24 hour fasted rats. The general course of changes obtained after the arrangement of adrenal strips deriving from the adrenals of rats exposed to cold and IM stress (CIMS) at +10 degrees C to -25 degrees C during the different time fragments presented the adrenal CA depletion events followed sometimes by the adrenal CA content increase after the longer stress exposure or/and stronger CIMS and WIMS conditions. It was found that this depletion-stimulated increase of adrenal Ca synthesis rate had been accelerated in 24 h fasted rats compared to satiated ones exposed to the same stress conditions, especially after the CIMS exposure. Moreover the survival time duration at first lethal temperature (-5 degrees C and +45 degrees C) was significantly higher in fasted rats. The possible hypothalamic regulation of adrenal CA synthesis rate accordingly to the actual metabolism needs and beta-adrenoceptor sensitivity changes depending on satiety state have been discussed and the necessity of further investigations concerning the specificity of stress-induced metabolism changes in 24 h starved rats has been suggested.

  18. Dietary quality varies according to data collection instrument: a comparison between a food frequency questionnaire and 24-hour recall.

    PubMed

    Rodrigues, Paulo Rogério Melo; de Souza, Rita Adriana Gomes; De Cnop, Mara Lima; Monteiro, Luana Silva; Coura, Camila Pinheiro; Brito, Alessandra Page; Pereira, Rosangela Alves

    2016-02-01

    The objective of this study was to assess the agreement between the Brazilian Healthy Eating Index - Revised (BHEI-R), estimated by a food frequency questionnaire (FFQ) and multiple 24-hour recalls (24h-R). The Wilcoxon paired test, partial correlations (PC), intraclass correlation coefficient (ICC), and Bland-Altman method were used. The total BHEI-R scores and its components ("total fruits", "whole fruits", "total vegetables", "integral cereals", "saturated fat", "sodium", and "energy intake derived from solid fat, added sugar, and alcoholic beverages") were statistically different, with the ICC and PC indicating poor concordance and correlation. The mean concordance estimated for the total BHEI-R and its components varied from 68% for "integral cereals" to 147% for "whole fruits". The suitable concordance limits were violated for most of the components of the BHEI-R. Poor concordance was observed between the BHEI-R estimated by the FFQ and by multiple 24h-R, which indicated a strong reliability of the BHEI-R on the instrument used to collect information on food consumption. PMID:26910251

  19. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome

    PubMed Central

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support. PMID:27398166

  20. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome.

    PubMed

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support.

  1. Comparative studies on 24-hour urinary excretion in Japanese and Chinese adults and children--need for nutritional education.

    PubMed

    Mori, Mari; Xu, Jin-Wen; Mori, Hideki; Ling, Cheng Feng; Wei, Guo Hong; Yamori, Yukio

    2009-01-01

    In order to evaluate the effect of nutritional education on the risk of developing lifestyle-related diseases, we measured taurine and isoflavone content in 24-hour urine samples (24-U) of 3rd grade Chinese children (CC) and of age-matched Japanese children (JC), as well as adult Chinese and Japanese (CA, JA) according to the WHO-CARDIAC (Cardiovascular Diseases and Alimentary Comparison) Study protocol. There was a significantly higher prevalence of obesity and "thin" individuals in CC compared with JC. While K intake was not significantly different in the children, the sodium to potassium ratio (Na/ K) and the intake of sodium chloride (NaCl) were significantly higher in CC than in JC. Taurine excretion (24-U) was significantly higher in CC than in JC, but isoflavone excretion was significantly lower in CC than in JC. Taurine excretion was significantly lower in CA than in JA, while isoflavone excretion was almost the same in CA and JA. After nutritional education CC consumed more isoflavones than the control group that had been subjected to only environmental education. JC exhibited significantly higher 24-U taurine and isoflavone excretion after taking the nutritional class.

  2. Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep.

    PubMed

    Tremblay, Mark S; Carson, Valerie; Chaput, Jean-Philippe; Connor Gorber, Sarah; Dinh, Thy; Duggan, Mary; Faulkner, Guy; Gray, Casey E; Gruber, Reut; Janson, Katherine; Janssen, Ian; Katzmarzyk, Peter T; Kho, Michelle E; Latimer-Cheung, Amy E; LeBlanc, Claire; Okely, Anthony D; Olds, Timothy; Pate, Russell R; Phillips, Andrea; Poitras, Veronica J; Rodenburg, Sophie; Sampson, Margaret; Saunders, Travis J; Stone, James A; Stratton, Gareth; Weiss, Shelly K; Zehr, Lori

    2016-06-01

    Leaders from the Canadian Society for Exercise Physiology convened representatives of national organizations, content experts, methodologists, stakeholders, and end-users who followed rigorous and transparent guideline development procedures to create the Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep. These novel guidelines for children and youth aged 5-17 years respect the natural and intuitive integration of movement behaviours across the whole day (24-h period). The development process was guided by the Appraisal of Guidelines for Research Evaluation (AGREE) II instrument and systematic reviews of evidence informing the guidelines were assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Four systematic reviews (physical activity, sedentary behaviour, sleep, integrated behaviours) examining the relationships between and among movement behaviours and several health indicators were completed and interpreted by expert consensus. Complementary compositional analyses were performed using Canadian Health Measures Survey data to examine the relationships between movement behaviours and health indicators. A stakeholder survey was employed (n = 590) and 28 focus groups/stakeholder interviews (n = 104) were completed to gather feedback on draft guidelines. Following an introductory preamble, the guidelines provide evidence-informed recommendations for a healthy day (24 h), comprising a combination of sleep, sedentary behaviours, light-, moderate-, and vigorous-intensity physical activity. Proactive dissemination, promotion, implementation, and evaluation plans have been prepared in an effort to optimize uptake and activation of the new guidelines. Future research should consider the integrated relationships among movement behaviours, and similar integrated guidelines for other age groups should be developed. PMID:27306437

  3. Risk Stratification by 24-Hour Ambulatory Blood Pressure and Estimated Glomerular Filtration Rate in 5322 Subjects From 11 Populations

    PubMed Central

    Boggia, José; Thijs, Lutgarde; Li, Yan; Hansen, Tine W.; Kikuya, Masahiro; Björklund-Bodegård, Kristina; Ohkubo, Takayoshi; Jeppesen, Jørgen; Torp-Pedersen, Christian; Dolan, Eamon; Kuznetsova, Tatiana; Stolarz-Skrzypek, Katarzyna; Tikhonoff, Valérie; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Schwedt, Emma; Sandoya, Edgardo; Kawecka-Jaszcz, Kalina; Filipovský, Jan; Imai, Yutaka; Wang, Jiguang; Ibsen, Hans; O’Brien, Eoin; Staessen, Jan A.

    2013-01-01

    No previous study addressed whether in the general population estimated glomerular filtration rate (eGFR [Chronic Kidney Disease Epidemiology Collaboration formula]) adds to the prediction of cardiovascular outcome over and beyond ambulatory blood pressure. We recorded health outcomes in 5322 subjects (median age, 51.8 years; 43.1% women) randomly recruited from 11 populations, who had baseline measurements of 24-hour ambulatory blood pressure (ABP24) and eGFR. We computed hazard ratios using multivariable-adjusted Cox regression. Median follow-up was 9.3 years. In fully adjusted models, which included both ABP24 and eGFR, ABP24 predicted (P≤0.008) both total (513 deaths) and cardiovascular (206) mortality; eGFR only predicted cardiovascular mortality (P=0.012). Furthermore, ABP24 predicted (P≤0.0056) fatal combined with nonfatal events as a result of all cardiovascular causes (555 events), cardiac disease (335 events), or stroke (218 events), whereas eGFR only predicted the composite cardiovascular end point and stroke (P≤0.035). The interaction terms between ABP24 and eGFR were all nonsignificant (P≥0.082). For cardiovascular mortality, the composite cardiovascular end point, and stroke, ABP24 added 0.35%, 1.17%, and 1.00% to the risk already explained by cohort, sex, age, body mass index, smoking and drinking, previous cardiovascular disease, diabetes mellitus, and antihypertensive drug treatment. Adding eGFR explained an additional 0.13%, 0.09%, and 0.14%, respectively. Sensitivity analyses stratified for ethnicity, sex, and the presence of hypertension or chronic kidney disease (eGFR <60 mL/min per 1.73 m2) were confirmatory. In conclusion, in the general population, eGFR predicts fewer end points than ABP24. Relative to ABP24, eGFR is as an additive, not a multiplicative, risk factor and refines risk stratification 2- to 14-fold less. PMID:23172928

  4. Accuracy of children's school-breakfast reports and school-lunch reports (in 24-hour dietary recalls) differs by retention interval

    PubMed Central

    Baxter, Suzanne Domel; Guinn, Caroline H.; Royer, Julie A.; Hardin, James W.; Mackelprang, Alyssa J.; Smith, Albert F.

    2009-01-01

    Background/Objectives Validation-study data were analyzed to investigate the effect of retention interval (time between the to-be-reported meal and interview) on accuracy of children's school-breakfast reports and school-lunch reports in 24-hour recalls, and to compare accuracy of children's school-breakfast reports for two breakfast locations (classroom; cafeteria). Subjects/Methods Each of 374 fourth-grade children was interviewed to obtain a 24-hour recall using one of six conditions from crossing two target periods (prior 24 hours; previous day) with three interview times (morning; afternoon; evening). Each condition had 62 or 64 children (half boys). A recall's target period included one school breakfast and one school lunch, for which the child had been observed. Food-item variables (observed number; reported number; omission rate; intrusion rate) and energy variables (observed; reported; report rate; correspondence rate; inflation ratio) were calculated for each child for school breakfast and school lunch separately. Results Accuracy for school-breakfast reports and school-lunch reports was inversely related to retention interval. Specifically, as indicated by smaller omission rates, smaller intrusion rates, larger correspondence rates, and smaller inflation ratios, accuracy for school-breakfast reports was best for prior-24-hour recalls in the morning, and accuracy for school-lunch reports was best for prior-24-hour recalls in the afternoon. For neither school meal was a significant sex effect found for any variable. For school-breakfast reports, there was no significant school-breakfast location effect for any variable. Conclusions By shortening the retention interval, accuracy can be improved for school-breakfast reports and school-lunch reports in children's 24-hour recalls. PMID:19756033

  5. Computerized portion-size estimation compared to multiple 24-hour dietary recalls for measurement of fat, fruit, and vegetable intake in overweight adults.

    PubMed

    Toobert, Deborah J; Strycker, Lisa A; Hampson, Sarah E; Westling, Erika; Christiansen, Steven M; Hurley, Thomas G; Hébert, James R

    2011-10-01

    Validated self-report methods of dietary assessment exist and might be improved in terms of both accuracy and cost-efficiency with computer technology. The objectives of this preliminary study were to develop an initial version of an interactive CD-ROM program to estimate fruit, vegetable, and fat intake, and to compare it to multiple 24-hour dietary recalls (averaged over 3 days). In 2009, overweight male and female adults (n=205) from Lane County, OR, completed computerized and paper versions of fruit, vegetable, and fat screening instruments, and multiple 24-hour dietary recalls. Summary scores from the 10-item National Cancer Institute Fruit and Vegetable Scan and the 18-item Block Fat Screener were compared to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake estimates (criterion measures). Measurement models were used to derive deattenuated correlations with multiple 24-hour dietary recalls of paper and CD-ROM administrations of Fruit and Vegetable Scan fruit intake, vegetable intake, and fruit and vegetable intake, and Block Fat Screener fat intake. The computerized assessment and paper surveys were related to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake. Deattenuated correlation coefficients ranged from 0.50 to 0.73 (all P≤0.0001). The CD-ROM-derived estimate of fruit intake was more closely associated with 24-hour dietary recall (r=0.73) than the paper-derived estimate (r=0.54; P<0.05), but the other comparisons did not differ significantly. Findings from this preliminary study with overweight adults indicate the need for additional enhancements to the CD-ROM assessment and more extensive validation studies.

  6. Computerized portion-size estimation compared to multiple 24-hour dietary recalls for measurement of fat, fruit, and vegetable intake in overweight adults.

    PubMed

    Toobert, Deborah J; Strycker, Lisa A; Hampson, Sarah E; Westling, Erika; Christiansen, Steven M; Hurley, Thomas G; Hébert, James R

    2011-10-01

    Validated self-report methods of dietary assessment exist and might be improved in terms of both accuracy and cost-efficiency with computer technology. The objectives of this preliminary study were to develop an initial version of an interactive CD-ROM program to estimate fruit, vegetable, and fat intake, and to compare it to multiple 24-hour dietary recalls (averaged over 3 days). In 2009, overweight male and female adults (n=205) from Lane County, OR, completed computerized and paper versions of fruit, vegetable, and fat screening instruments, and multiple 24-hour dietary recalls. Summary scores from the 10-item National Cancer Institute Fruit and Vegetable Scan and the 18-item Block Fat Screener were compared to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake estimates (criterion measures). Measurement models were used to derive deattenuated correlations with multiple 24-hour dietary recalls of paper and CD-ROM administrations of Fruit and Vegetable Scan fruit intake, vegetable intake, and fruit and vegetable intake, and Block Fat Screener fat intake. The computerized assessment and paper surveys were related to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake. Deattenuated correlation coefficients ranged from 0.50 to 0.73 (all P≤0.0001). The CD-ROM-derived estimate of fruit intake was more closely associated with 24-hour dietary recall (r=0.73) than the paper-derived estimate (r=0.54; P<0.05), but the other comparisons did not differ significantly. Findings from this preliminary study with overweight adults indicate the need for additional enhancements to the CD-ROM assessment and more extensive validation studies. PMID:21963026

  7. Comparison of gastric body and antral pH: a 24 hour ambulatory study in healthy volunteers.

    PubMed

    McLauchlan, G; Fullarton, G M; Crean, G P; McColl, K E

    1989-05-01

    Simultaneous ambulatory records of gastric antral and body pH were made over 24 hours in nine healthy volunteers by means of endoscopically positioned and anchored glass electrodes. Intragastric pH was temporarily raised after the endoscopy with the median pH value 30 minutes after the procedure being 3.9 (range 1.5-7.0) for the antrum and 4.1 (range 1.5-7.0) for the body. Daytime pH (median pH value between 12 00 h and 23 00 h) was lower in the antrum (median = 1.9, range 1.6-2.6) than in the body (median = 2.7, range 1.8-4.5) (p less than 0.05) and this was because of the rise in pH on eating being less marked in the antrum than in the body. The median peak pH recorded during the evening meal was only 4.1 (range 2.4-6.2) in the antrum compared with 6.3 (range 4.4-6.7) in the body (p less than 0.01). Preprandial pH (median value over the hour prior to the evening meal) was similar in the antrum (median = 1.9, range 1.2-2.5) and body (median = 1.9, range 1.3-2.8). Night-time pH (median pH value between 23 00 h and 05 00 h) in six subjects remained low and was similar in the antrum (median = 1.4, range 1.2-1.7) and body (median = 1.3, range 1.1-1.7). In two subjects, however, there were episodes of raised night-time pH which were more marked in the antrum than in the body. Antral biopsies showed gastritis in four of the nine normal volunteers, which in three was associated with the presence of campylobacter-like organisms. This study shows the significant regional variations in day and night-time intragastric pH.

  8. Identifying nutrients that are under-reported by an automated 24-hour dietary recall method in overweight and obese women after weight loss

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Underreporting of energy intake by 15-50% is a common problem in dietary assessment. Evidence suggests overweight/obese respondents are more likely to under-report than normal weight. This study compared Automated Self-Administered 24-hour recall (ASA24)-reported dietary intake to true intake in ove...

  9. Validation of the automated self-administered 24-hour dietary recall for children (ASA24-Kids) among 9- to 11-year-old youth

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our purpose was to validate ASA24-Kids-2012, a self-administered web-based 24-hour dietary recall (24hDR) among 9- to 11-year-old children. Sixty-nine children in two sites participated in the study. In one site, trained staff observed and recorded types and portions of foods and drinks consumed by ...

  10. Ambulatory 24 hour intraoesophageal pH and pressure recordings v provocation tests in the diagnosis of chest pain of oesophageal origin.

    PubMed Central

    Ghillebert, G; Janssens, J; Vantrappen, G; Nevens, F; Piessens, J

    1990-01-01

    Fifty patients with non-cardiac chest pain underwent 24 hour intraoesophageal pH and pressure recording and provocation tests to determine the relative value of both techniques in establishing the oesophageal origin of the chest pain. Twenty six patients (52%) had at least one positive provocation test: the acid perfusion test was positive related in 18 patients (36%), the edrophonium test in 16 patients (32%), the vasopressin test in five patients (10%), and the balloon distension test (performed in only 20 patients) in one (5%). The 24 hour pH and pressure recording correlated spontaneous chest pain attacks with abnormal motility or gastro-oesophageal reflux in 19 patients (38%). Fourteen of these patients also had at least one positive provocation test. Therefore, 24 hour pH and pressure recordings are only slightly better than a set of provocation tests in identifying the oesophagus as the cause of chest pain (10% diagnostic gain). In the case of oesophageal chest pain, however, 24 hour recording appeared to be the only way to identify the nature of the underlying oesophageal abnormality that caused the spontaneous pain attacks--for example, gastro-oesophageal reflux, motility disorders, or irritability of the oesophagus. PMID:2370009

  11. Bath water contamination with Legionella and nontuberculous mycobacteria in 24-hour home baths, hot springs, and public bathhouses of Nagano Prefecture, Japan.

    PubMed

    Kobayashi, Michiko; Oana, Kozue; Kawakami, Yoshiyuki

    2014-01-01

    Bath water samples were collected from 116 hot springs, 197 public bathhouses, and 38 24-hour home baths in Nagano Prefecture, Japan, during the period of April 2009 to November 2011, for determining the presence and extent of contamination with Legionella and nontuberculous mycobacteria. Cultures positive for Legionella were observed in 123 of the 3,314 bath water samples examined. The distribution and abundance of Legionella and/or combined contamination with Legionella and nontuberculous mycobacteria were investigated to clarify the contamination levels. The abundance of Legionella was demonstrated to correlate considerably with the levels of combined contamination with Legionella and nontuberculous mycobacteria. Legionella spp. were obtained from 61% of the water samples from 24-hour home baths, but only from 3% of the samples from public bathhouses and hot springs. This is despite the fact that a few outbreaks of Legionnaires' disease in Nagano Prefecture as well as other regions of Japan have been traced to bath water contamination. The comparatively higher rate of contamination of the 24-hour home baths is a matter of concern. It is therefore advisable to routinely implement good maintenance of the water basins, particularly of the 24-hour home baths.

  12. The effect of low level radiofrequency electromagnetic radiation on the excretion rates of stress hormones in operators during 24-hour shifts.

    PubMed

    Vangelova, K; Israel, M; Mihaylov, S

    2002-06-01

    The aim of the study was to investigate the effect of long term exposure to low level radiofrequency (RF) electromagnetic (EM) radiation on the excretion rates of stress hormones in satellite station operators during 24-hour shifts. Twelve male operators at a satellite station for TV communications and space research were studied during 24-hour shifts. Dosimetric evaluation of the exposure was carried out and showed low level exposure with specific absorption of 0.1127 J.kg-1. A control group of 12 unexposed male operators with similar job task and the same shift system were studied, too. The 11-oxycorticosteroids (11-OCS), adrenaline and noradrenaline were followed by spectrofluorimetric methods on 3-hour intervals during the 24-hour shifts. The data were analyzed by tests for interindividual analysis, Cosinor analysis and analysis of variance (ANOVA). Significant increase in the 24-hour excretion of 11-OCS and disorders in its circadian rhythm, manifested by increase in the mesor, decrease in the amplitude and shift in the acrophase were found in the exposed operators. The changes in the excretion rates of the catecholamines were significant and showed greater variability of both variables. The long term effect of the exposure to low-level RF EM radiation evoked pronounced stress reaction with changes in the circadian rhythm of 11-OCS and increased variability of catecholamines secretion. The possible health hazards associated with observed alteration in the stress system need to be clarified by identification of their significance and prognostic relevance.

  13. Characterization of pulmonary protein profiles in response to zinc oxide nanoparticles in mice: a 24-hour and 28-day follow-up study.

    PubMed

    Pan, Chih-Hong; Chuang, Kai-Jen; Chen, Jen-Kun; Hsiao, Ta-Chih; Lai, Ching-Huang; Jones, Tim P; BéruBé, Kelly A; Hong, Gui-Bing; Ho, Kin-Fai; Chuang, Hsiao-Chi

    2015-01-01

    Although zinc oxide nanoparticles (ZnONPs) are recognized to cause systemic disorders, little is known about the mechanisms that underlie the time-dependent differences that occur after exposure. The objective of this study was to investigate the mechanistic differences at 24 hours and 28 days after the exposure of BALB/c mice to ZnONPs via intratracheal instillation. An isobaric tag for the relative and absolute quantitation coupled with liquid chromatography/tandem mass spectrometry was used to identify the differential protein expression, biological processes, molecular functions, and pathways. A total of 18 and 14 proteins displayed significant changes in the lung tissues at 24 hours and 28 days after exposure, respectively, with the most striking changes being observed for S100-A9 protein. Metabolic processes and catalytic activity were the main biological processes and molecular functions, respectively, in the responses at the 24-hour and 28-day follow-up times. The glycolysis/gluconeogenesis pathway was continuously downregulated from 24 hours to 28 days, whereas detoxification pathways were activated at the 28-day time-point after exposure. A comprehensive understanding of the potential time-dependent effects of exposure to ZnONPs was provided, which highlights the metabolic mechanisms that may be important in the responses to ZnONP. PMID:26251593

  14. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBONPAK X SOLID ADSORBENT WITH THEMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDIES

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hours onto the graphitic adsorbent Carbopack X contained in a stainless steel tube badge (6.3 mm OD, 5 mm ID, and 90 mm in length) with analysis by thermal desorption/GC/MS has been evaluated in controlled tests. A test matrix of 42 tr...

  15. Association of Holter-Based Measures Including T-wave Alternans with Risk of Sudden Cardiac Death in the Community-Dwelling Elderly: The Cardiovascular Health Study

    PubMed Central

    Stein, Phyllis K.; Sanghavi, Devang; Sotoodehnia, Nona; Siscovick, David S; Gottdiener, John

    2010-01-01

    Background Sudden cardiac death (SCD) can be the first manifestation of cardiovascular disease. Development of screening methods for higher / lower risk is critical. Methods The Cardiovascular Healthy Study (CHS) is a population-based study of risk factors for coronary heart disease and stroke those ≥65 years. N=49 (of 1649) with usable Holters and in normal sinus rhythm, suffered SCD during follow up and were matched with 2 controls, alive at the time of death of the case and not suffering SCD on follow up. Univariate and multivariate conditional logistic regression determined the association of Holter-based information and SCD. Results In univariate models, the upper half of VPC counts, abnormal heart rate turbulence, decreased normalized low frequency power, increased T-wave alternans (TWA) and decreased DFA1 (short-term fractal scaling exponent) were associated with SCD, but time domain HRV was not. In multivariate models, the upper half of VPC counts (OR=6.6) and having TWA ≥37µV on Ch2 (OR=4.8) were independently associated with SCD. Also, the upper half of VPC counts (OR=6.9) and having DFA1 <1.05 (OR=5.0) were independently associated with SCD. When additive effects were explored: having both higher VPCs and higher TWA was associated with an OR of 8.2 for SCD compared to 2.6 for having either. Also, having both higher VPCs and lower DFA1 was associated with an OR of 9.6 for SCD compared to 3.1 for having either. Conclusions Results support a potential role for 24-hour Holter recordings to identify older adults at increased or lower risk of SCD. PMID:20096853

  16. Segment clustering methodology for unsupervised Holter recordings analysis

    NASA Astrophysics Data System (ADS)

    Rodríguez-Sotelo, Jose Luis; Peluffo-Ordoñez, Diego; Castellanos Dominguez, German

    2015-01-01

    Cardiac arrhythmia analysis on Holter recordings is an important issue in clinical settings, however such issue implicitly involves attending other problems related to the large amount of unlabelled data which means a high computational cost. In this work an unsupervised methodology based in a segment framework is presented, which consists of dividing the raw data into a balanced number of segments in order to identify fiducial points, characterize and cluster the heartbeats in each segment separately. The resulting clusters are merged or split according to an assumed criterion of homogeneity. This framework compensates the high computational cost employed in Holter analysis, being possible its implementation for further real time applications. The performance of the method is measure over the records from the MIT/BIH arrhythmia database and achieves high values of sensibility and specificity, taking advantage of database labels, for a broad kind of heartbeats types recommended by the AAMI.

  17. 76 FR 6056 - Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... Protection Agency FR Federal Register NAAQS National Ambient Air Quality Standards NTTAA National Technology... (74 FR 58688), EPA deferred designations for three areas to evaluate further the reason for their high... November 13, 2009 notice (74 FR 58688), we also announced that our review of 2006-2008 monitoring data...

  18. Cross-Sectional Study of 24-Hour Urinary Electrolyte Excretion and Associated Health Outcomes in a Convenience Sample of Australian Primary Schoolchildren: The Salt and Other Nutrients in Children (SONIC) Study Protocol

    PubMed Central

    Baxter, Janet R; Campbell, Karen J; Riddell, Lynn J; Rigo, Manuela; Liem, Djin Gie; Keast, Russell S; He, Feng J; Nowson, Caryl A

    2015-01-01

    Background Dietary sodium and potassium are involved in the pathogenesis of cardiovascular disease. Data exploring the cardiovascular outcomes associated with these electrolytes within Australian children is sparse. Furthermore, an objective measure of sodium and potassium intake within this group is lacking. Objective The primary aim of the Salt and Other Nutrient Intakes in Children (“SONIC”) study was to measure sodium and potassium intakes in a sample of primary schoolchildren located in Victoria, Australia, using 24-hour urine collections. Secondary aims were to identify the dietary sources of sodium and potassium, examine the association between these electrolytes and cardiovascular risk factors, and assess children’s taste preferences and saltiness perception of manufactured foods. Methods A cross-sectional study was conducted in a convenience sample of schoolchildren attending primary schools in Victoria, Australia. Participants completed one 24-hour urine collection, which was analyzed for sodium, potassium, and creatinine. Completeness of collections was assessed using collection time, total volume, and urinary creatinine. One 24-hour dietary recall was completed to assess dietary intake. Other data collected included blood pressure, body weight, height, waist and hip circumference. Children were also presented with high and low sodium variants of food products and asked to discriminate salt level and choose their preferred variant. Parents provided demographic information and information on use of discretionary salt. Descriptive statistics will be used to describe sodium and potassium intakes. Linear and logistic regression models with clustered robust standard errors will be used to assess the association between electrolyte intake and health outcomes (blood pressure and body mass index/BMI z-score and waist circumference) and to assess differences in taste preference and discrimination between high and low sodium foods, and correlations between

  19. 24-hour control of body temperature in the rat: II. Diisopropyl fluorophosphate-induced hypothermia and hyperthermia.

    PubMed

    Gordon, C J

    1994-11-01

    Diisopropyl fluorophosphate (DFP) and other anticholinesterase (antiChE) agents have been found to induce marked hypothermic responses in laboratory rodents. To characterize the effects of DFP on autonomic and behavioral thermoregulation, rats of the Long-Evans strain were injected with DFP while housed in a temperature gradient. The gradient allowed for the measurement of selected ambient temperature (Ta) and motor activity (MA) over a 6- to 7-day period. Core temperature (Tc) and heart rate (HR) were also monitored simultaneously using radiotelemetry. Injection of the peanut oil vehicle led to transient elevations in Tc, HR, and MA, but no change in selected Ta. The next day animals were injected with 0.25, 1.0, or 1.5 mg/kg DFP. DFP (1.0 AND 1.5 mg/kg) led to a marked reduction in Tc. The decrease in Tc was accompanied by reductions in HR, MA, and selected Ta. During the first night after DFP, selected Ta remained elevated as Tc recovered to its preinjection level. The second 24-h period after 1.0 and 1.5 mg/kg DFP was associated with a significant elevation in the daytime Tc. In conclusion, with the option of using behavioral thermoregulatory responses, the hypothermic effects of acute DFP treatment are mediated by a selection for cooler TaS. An elevation in Tc during recovery from acute DFP corroborates the many incidents of fever in humans exposed to anti-ChE agents. PMID:7862732

  20. Evaluating acellular versus cellular perfusate composition during prolonged ex vivo lung perfusion after initial cold ischaemia for 24 hours.

    PubMed

    Becker, Simon; Steinmeyer, Jasmin; Avsar, Murat; Höffler, Klaus; Salman, Jawad; Haverich, Axel; Warnecke, Gregor; Ochs, Matthias; Schnapper, Anke

    2016-01-01

    Normothermic ex vivo lung perfusion (EVLP) has developed as a powerful technique to evaluate particularly marginal donor lungs prior to transplantation. In this study, acellular and cellular perfusate compositions were compared in an identical experimental setting as no consensus has been reached on a preferred technique yet. Porcine lungs underwent EVLP for 12 h on the basis of an acellular or a cellular perfusate composition after 24 h of cold ischaemia as defined organ stress. During perfusion, haemodynamic and respiratory parameters were monitored. After EVLP, the lung condition was assessed by light and transmission electron microscopy. Aerodynamic parameters did not show significant differences between groups and remained within the in vivo range during EVLP. Mean oxygenation indices were 491 ± 39 in the acellular group and 513 ± 53 in the cellular group. Groups only differed significantly in terms of higher pulmonary artery pressure and vascular resistance in the cellular group. Lung histology and ultrastructure were largely well preserved after prolonged EVLP and showed only minor structural alterations which were similarly present in both groups. Prolonged acellular and cellular EVLP for 12 h are both feasible with lungs prechallenged by ischaemic organ stress. Physiological and ultrastructural analysis showed no superiority of either acellular or cellular perfusate composition.

  1. Novel description of the 24-hour circadian rhythms of brachial versus central aortic blood pressure and the impact of blood pressure treatment in a randomized controlled clinical trial: The Ambulatory Central Aortic Pressure (AmCAP) Study.

    PubMed

    Williams, Bryan; Lacy, Peter S; Baschiera, Fabio; Brunel, Patrick; Düsing, Rainer

    2013-06-01

    Elevated brachial blood pressure (BP) is associated with increased cardiovascular risk and predicts morbidity and mortality in humans. Recently, 24-hour ambulatory BP monitoring and assessment of central aortic BP have been introduced to improve BP phenotyping. The Ambulatory Central Aortic Pressure (AmCAP) study combines these approaches and describes, for the first time, the diurnal patterns of simultaneously measured 24-hour ambulatory brachial and central pressures in a prespecified substudy embedded within a clinical trial of BP lowering in patients with hypertension. Twenty-four-hour ambulatory brachial and central pressure measurements were acquired using a tonometer mounted into the articulating strap of a wristwatch-like device (BPro) in 171 participants with hypertension recruited into the ASSERTIVE (AliSkiren Study of profound antihypERtensive efficacy in hyperTensIVE patients) trial. Participants were randomly assigned to BP lowering with either aliskiren 300 mg QD or telmisartan 80 mg QD for 12 weeks. Ambulatory brachial and central BP was measured in all participants both at baseline and at study end. Brachial and central BP both demonstrated typical diurnal patterns with lower pressures at night. However, night time was associated with smaller reductions in central relative to brachial pressure and decreased pulse pressure amplification (P<0.0001 for both). These effects were not modulated after BP lowering and were maintained after adjustment for day and night-time BP and heart rate (P=0.02). This study demonstrates that brachial and central pressure show different diurnal patterns, which are not modulated by BP-lowering therapy, with relatively higher night-time central pressures. These novel data indicate that night-time central BP may provide prognostic importance and warrants further investigation. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00865020. PMID:23630950

  2. Decreased striatal dopamine release underlies increased expression of long-term synaptic potentiation at corticostriatal synapses 24 hours after 3-nitropropionic acid induced chemical hypoxia

    PubMed Central

    Akopian, Garnik; Crawford, Cynthia; Beal, M. Flint; Cappelletti, Maurand; Jakowec, Michael W.; Petzinger, Giselle M.; Zheng, Ling; Gheorghe, Stacey L.; Reichel, Carmela M.; Chow, Robert; Walsh, John P

    2008-01-01

    The striatum is particularly sensitive to the irreversible inhibitor of succinate dehyrdrogenase 3-nitropropionic acid (3-NP). In the present study we examined early changes in behavior and dopamine and glutamate synaptic physiology created by a single systemic injection of 3-NP in Fischer 344 rats. Hind limb dystonia was seen 2 hours after 3-NP injections and rats performed poorly on balance beam and rota-rod motor tests 24 hours later. Systemic 3-NP increased NMDA receptor-dependent long-term potentiation (LTP) at corticostriatal synapses over the same time period. The 3-NP induced corticostriatal LTP was not due to increased NMDA receptor number or function, since 3-NP did not change MK-801 binding or NMDA/AMPA receptor current ratios. The LTP seen 24 hours after 3-NP was D1 receptor-dependent and reversed by exogenous addition of dopamine or a D2 receptor agonist to brain slices. High performance liquid chromatography and fast scan cyclic voltammetry revealed a decrease in dopamine content and release in rats injected 24 hours earlier with 3-NP, and much like the enhanced LTP, dopamine changes were reversed by 48 hours. Tyrosine hydroxylase expression was not changed and there was no evidence of striatal cell loss at 24–48 hours after 3-NP exposure. Sprague-Dawley rats showed similar physiological responses to systemic 3-NP, albeit with reduced sensitivity. Thus, 3-NP causes significant changes in motor behavior marked by parallel changes in striatal dopamine release and corticostriatal synaptic plasticity. PMID:18799690

  3. Development and validity of a 3-day smartphone-assisted 24-hour recall to assess beverage consumption in a Chinese population: a randomized cross-over study

    PubMed Central

    Smith, Lindsey P.; Hua, Jenna; Seto, Edmund; Du, Shufa; Zang, Jiajie; Zou, Shurong; Popkin, Barry M.; Mendez, Michelle A.

    2014-01-01

    This paper addresses the need for diet assessment methods that capture the rapidly changing beverage consumption patterns in China. The objective of this study was to develop a 3-day smartphone-assisted 24-hour recall to improve the quantification of beverage intake amongst young Chinese adults (n=110) and validate, in a small subset (n=34), the extent to which the written record and smartphone-assisted recalls adequately estimated total fluid intake, using 24-hour urine samples. The smartphone-assisted method showed improved validity compared to the written-assisted method, when comparing reported total fluid intake to total urine volume. However, participants reported consuming fewer beverages on the smartphone-assisted method compared to the written-assisted method, primarily due to decreased consumption of traditional zero-energy beverages (i.e. water, tea) in the smartphone-assisted method. It is unclear why participants reported fewer beverages in the smartphone-assisted method than the written-assisted method. One possibility is that participants found the smartphone method too cumbersome, and responded by decreasing beverage intake. These results suggest that smartphone-assisted 24-hour recalls perform comparably but do not appear to substantially improve beverage quantification compared to the current written record based approach. In addition, we piloted a beverage screener to identify consumers of episodically consumed SSBs. As expected, a substantially higher proportion of consumers reported consuming SSBs on the beverage screener compared to either recall type, suggesting that a beverage screener may be useful in characterizing consumption of episodically consumed beverages in China’s dynamic food and beverage landscape. PMID:25516327

  4. Comparison of cimetidine and ranitidine on 24-hour intragastric acidity and serum gastrin profile in patients with esophagitis.

    PubMed

    Mahachai, V; Walker, K; Thomson, A B; Zuk, L; Kirdeikis, P; Fisher, D; Brunet, K

    1985-04-01

    Twenty-four-hour intragastric pH and serum gastrin profiles were monitored in six male asymptomatic patients who previously were found to have esophagitis on endoscopy and biopsy. They received cimetidine 300 mg qid (C), ranitidine 150 mg bid (R), or placebo (P) for one week each, utilizing the Latin-square design. The mean BAO was 0.4 +/- 0.2 mmol/hr, and the pentagastrin-stimulated MAO was 21.2 +/- 3.2 mmol/hr. In the P-treated patients, the pH fluctuated between 1.8 and 3.5 and over 90% of the readings were less than pH 4. As compared to P, both C and R significantly suppressed H+ after breakfast, overnight, and over the 24-hr period. The mean pH after lunch was significantly higher in R than in P, but not in C. Over the 24-hr period, a higher percentage of the readings were above pH 4.0 in R as compared to C. During the night, 50% of the pH readings were above pH 4.0 in C and R, whereas in P 50% of the pH readings were less than pH 2.0. The integrated gastrin responses after each meal were similar in C and R and were greater than in P. The biphasic response of the ratio of H+ and gastrin (H+/G) following each meal was suppressed by both H2-receptor antagonists, with numerically lower values obtained in R than in C. This study suggests that ranitidine 150 mg bid is superior to cimetidine 300 mg qid in suppressing the 24-hr intragastric acidity.

  5. [The normalisation of blood sugar using a non-miniaturised artifical pancreas. Application for 24 hours in 7 insulin-dependent diabetics (author's transl)].

    PubMed

    Slama, G; Klein, J C; Tardieu, M C; Tchobroutsky, G

    1977-06-25

    Seven insulin-dependent diabetic were treated for 24 to 36 hours by intravenous injections of insulin adapted to variations in blood glucose using a fairly voluminous automatic regulation device. This artificial pancreas consists of a modified Technicon blood sugar apparatus which provides continuous estimation of blood glucose using non-haemolysed whole blood by a glucose oxidase method with an inertia time of 6 minutes, a table calculator and a newly developed interpretation and command electronic unit (GlucostatR). Normalisation of blood glucose was obtained for at least 24 hours, during and between meals, during a period following an oral glucose load and throughout the night.

  6. Treatment of burns in the first 24 hours: simple and practical guide by answering 10 questions in a step-by-step form

    PubMed Central

    2012-01-01

    Residents in training, medical students and other staff in surgical sector, emergency room (ER) and intensive care unit (ICU) or Burn Unit face a multitude of questions regarding burn care. Treatment of burns is not always straightforward. Furthermore, National and International guidelines differ from one region to another. On one hand, it is important to understand pathophysiology, classification of burns, surgical treatment, and the latest updates in burn science. On the other hand, the clinical situation for treating these cases needs clear guidelines to cover every single aspect during the treatment procedure. Thus, 10 questions have been organised and discussed in a step-by-step form in order to achieve the excellence of education and the optimal treatment of burn injuries in the first 24 hours. These 10 questions will clearly discuss referral criteria to the burn unit, primary and secondary survey, estimation of the total burned surface area (%TBSA) and the degree of burns as well as resuscitation process, routine interventions, laboratory tests, indications of Bronchoscopy and special considerations for Inhalation trauma, immediate consultations and referrals, emergency surgery and admission orders. Understanding and answering the 10 questions will not only cover the management process of Burns during the first 24 hours but also seems to be an interactive clear guide for education purpose. PMID:22583548

  7. Estimation of 24-hour thyroid uptake of I-131 sodium iodide using a 5-minute uptake of technetium-99m pertechnetate

    SciTech Connect

    Smith, J.J.; Croft, B.Y.; Brookeman, V.A.; Teates, C.D. )

    1990-02-01

    The authors have developed a method to estimate the 24-hour sodium iodide thyroid uptake based on a 5-minute Tc-99m pertechnetate thyroid uptake using the equation: Estimated Iodide Uptake = 17.72*In(Pertechnetate Uptake) + 30.40. This estimation has a correlation coefficient of 0.90. It is based on a data pool of 44 patients who underwent I-131 and Tc-99m studies within 2 weeks of each other from 1978-1988, with established diagnoses as follows: 12 euthyroid, 6 hyperthyroid with multinodular goiters, 15 hyperthyroid with diffuse goiters, 4 with subacute thyroiditis, and 7 unknown. The population consisted of 30 women and 14 men with a mean age of 52.0 +/- 17.5 years; this sample was screened for use of thyroid hormone, propylthiouracil, and radiographic contrast. The authors believe this estimation method is of value whenever a 24-hour iodide uptake is desired, and where speed and minimizing radiation dose are factors. This method is strongly recommended for thyroid uptake evaluation before I-131 therapy.

  8. [How to express results of 24-hour gastric pH measurement? Choice of a mode of expression in 27 healthy subjects].

    PubMed

    Vallot, T; Elouaer-Blanc, L; Garcia del Risco, F; Mignon, M; Vatier, J; Bonfils, S

    1988-01-01

    Twenty-four hour intragastric acidity was studied in 27 healthy subjects (mean age = 29 yrs) by continuous recording in standardized conditions. Data obtained were expressed according to several analytical methods as used extensively elsewhere. In our study, there was a wide discrepancy in results from one subject to another. The use of median values of pH was more appropriate than mean values to express half-hour acidity levels for 24 hours. The median value of H+ concentration is recommended as well. The median value of pH varied from 1 to 4.8 with a slight rise during the second half of the night. During the postprandial period, increase of pH values was prolonged over 2 h 30 in 50 p. 100 of subjects. Profile of pH allowed to demonstrate the distribution of pH value without excluding the extreme values. Both periodicity of pH measurement (30 or 60 min) and parameters used to quantify acidity (percentage of time or pH value at or below threshold values) did not modify results. As measured over a 24 hours period, the percentage of time (mean +/- SEM) at or below pH 1.5 and 3.5 was 54 +/- 3 p. 100 and 85 +/- 2 p. 100, respectively. Daytime and night-time profiles were similar. Mean 24 h H+ concentration (mean +/- SEM) was 47 +/- 35 mmol/l, with, once again, similarity between day and night-time values. The mean 24 h pH values underestimated true acidity with respect to median values.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Demand and characteristics of a psychiatric 24-hour emergency service performed by mandatory rotation of licensed psychiatrists in Swiss primary care

    PubMed Central

    Chmiel, Corinne; Rosemann, Thomas; Senn, Oliver

    2014-01-01

    Background To investigate characteristics of and satisfaction with psychiatric 24-hour emergency primary care performed by mandatory rotation of licensed psychiatrists as a viable baseline for possible reorganizational measures. Methods This was a questionnaire-based cross-sectional study (November 2010–April 2011). The number of patient–psychiatrist encounters, modes of contact, and patient and psychiatrist characteristics were assessed. Diagnoses were coded with ICD-10 (International Classification of Diseases, version 10). Results From 167 duty episodes, 74 (44%) were recorded. Of the psychiatrists (n=44), 52% were female, and mean age (standard deviation) was 49.9 (5.2) years. The median number of encounters per episode was 4 (interquartile range 0–8), mainly in the evenings. Demand for “face-to-face” (direct) patient visits was significantly more common (64.0%) than practice (1.3%) or telephone consultations (34.7%). In 83.8%, psychiatrists judged the encounter as adequate at the patient’s location. A total of 43 different diagnoses were recorded: mainly schizophrenic disorders (23.9%), suicidal behavior (15.2%), and acute stress reactions (10.3%). Psychiatrists felt burdened by services (62.5%): in 39.2%, they felt threatened; and in 6.8%, violence occurred. In 32.4%, bills were not paid for. If services were optional, 45.2% would participate. Conclusion Our findings indicate justified demand for direct mobile patient visits, suggesting that emergency care should be multifaceted, and sole provision of psychiatric care at stationed emergency facilities may not always be appropriate. Reorganization of 24-hour emergency services should carefully evaluate patient and provider’s needs before changing established structures. PMID:24707172

  10. Cardiac safety of tiotropium in patients with COPD: a combined analysis of Holter-ECG data from four randomised clinical trials

    PubMed Central

    Hohlfeld, J M; Furtwaengler, A; Könen-Bergmann, M; Wallenstein, G; Walter, B; Bateman, E D

    2015-01-01

    Background Tiotropium is generally well tolerated; however, there has been debate whether antimuscarinics, particularly tiotropium administered via Respimat® Soft Mist™ Inhaler, may induce cardiac arrhythmias in a vulnerable subpopulation with cardiovascular comorbidity. The aim of this study was to provide evidence of the cardiac safety of tiotropium maintenance therapy. Methods Combined analysis of Holter electrocardiogram (ECG) data from clinical trials of tiotropium in chronic obstructive pulmonary disease (COPD). Trials in the Boehringer Ingelheim clinical trials database conducted between 2003 and 2012, involving tiotropium HandiHaler® 18 μg and/or tiotropium Respimat® (1.25-, 2.5-, 5.0- and 10-μg doses) were reviewed. All trials involving Holter-ECG monitoring during this period were included in the analysis. Men and women aged ≥ 40 years with a smoking history of ≥ 10 pack-years, and a clinical diagnosis of COPD were included. Holter ECGs were evaluated for heart rate (HR), supraventricular premature beats (SVPBs), ventricular premature beats (VPBs) and pauses. Quantitative and categorical end-points were derived for each of the Holter monitoring days. Results Four trials (n = 727) were included in the analysis. Respimat® (1.25–10 μg) or HandiHaler® (18 μg) was not associated with changes in HR, SVPBs, VPBs and pauses compared with placebo or the pretreatment baseline period. In terms of cardiac arrhythmia end-points, there was no evidence for an exposure–effect relationship. Conclusions In this analysis, tiotropium maintenance therapy administered using Respimat® (1.25–10 μg) or HandiHaler® (18 μg) once daily for periods of up to 48 weeks was well tolerated with no increased risk of cardiac arrhythmia in patients with COPD. PMID:25496316

  11. Ambulatory Hypertension Subtypes and 24-Hour Systolic and Diastolic Blood Pressure as Distinct Outcome Predictors in 8341 Untreated People Recruited From 12 Populations

    PubMed Central

    Li, Yan; Wei, Fang-Fei; Thijs, Lutgarde; Boggia, José; Asayama, Kei; Hansen, Tine W.; Kikuya, Masahiro; Björklund-Bodegård, Kristina; Ohkubo, Takayoshi; Jeppesen, Jørgen; Gu, Yu-Mei; Torp-Pedersen, Christian; Dolan, Eamon; Liu, Yan-Ping; Kuznetsova, Tatiana; Stolarz-Skrzypek, Katarzyna; Tikhonoff, Valérie; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Sandoya, Edgardo; Kawecka-Jaszcz, Kalina; Mena, Luis; Maestre, Gladys E.; Filipovský, Jan; Imai, Yutaka; O’Brien, Eoin; Wang, Ji-Guang; Staessen, Jan A.

    2015-01-01

    Background Data on risk associated with 24-hour ambulatory diastolic (DBP24) versus systolic (SBP24) blood pressure are scarce. Methods and Results We recorded 24-hour blood pressure and health outcomes in 8341 untreated people (mean age, 50.8 years; 46.6% women) randomly recruited from 12 populations. We computed hazard ratios (HRs) using multivariable-adjusted Cox regression. Over 11.2 years (median), 927 (11.1%) participants died, 356 (4.3%) from cardiovascular causes, and 744 (8.9%) experienced a fatal or nonfatal cardiovascular event. Isolated diastolic hypertension (DBP24≥80 mm Hg) did not increase the risk of total mortality, cardiovascular mortality, or stroke (HRs≤1.54; P≥0.18), but was associated with a higher risk of fatal combined with nonfatal cardiovascular, cardiac, or coronary events (HRs≥1.75; P≤0.0054). Isolated systolic hypertension (SBP24≥130 mm Hg) and mixed diastolic plus systolic hypertension were associated with increased risks of all aforementioned end points (P≤0.0012). Below age 50, DBP24 was the main driver of risk, reaching significance for total (HR for 1-SD increase, 2.05; P=0.0039) and cardiovascular mortality (HR, 4.07; P=0.0032) and for all cardiovascular end points combined (HR, 1.74; P=0.039) with a nonsignificant contribution of SBP24 (HR≤0.92; P≥0.068); above age 50, SBP24 predicted all end points (HR≥1.19; P≤0.0002) with a nonsignificant contribution of DBP24 (0.96≤HR≤1.14; P≥0.10). The interactions of age with SBP24 and DBP24 were significant for all cardiovascular and coronary events (P≤0.043). Conclusions The risks conferred by DBP24 and SBP24 are age dependent. DBP24 and isolated diastolic hypertension drive coronary complications below age 50, whereas above age 50 SBP24 and isolated systolic and mixed hypertension are the predominant risk factors. PMID:24906822

  12. Metabolic Engineering of Light and Dark Biochemical Pathways in Wild-Type and Mutant Strains of Synechocystis PCC 6803 for Maximal, 24-Hour Production of Hydrogen Gas

    SciTech Connect

    Ely, Roger L.; Chaplen, Frank W.R.

    2014-03-11

    This project used the cyanobacterial species Synechocystis PCC 6803 to pursue two lines of inquiry, with each line addressing one of the two main factors affecting hydrogen (H2) production in Synechocystis PCC 6803: NADPH availability and O2 sensitivity. H2 production in Synechocystis PCC 6803 requires a very high NADPH:NADP+ ratio, that is, the NADP pool must be highly reduced, which can be problematic because several metabolic pathways potentially can act to raise or lower NADPH levels. Also, though the [NiFe]-hydrogenase in PCC 6803 is constitutively expressed, it is reversibly inactivated at very low O2 concentrations. Largely because of this O2 sensitivity and the requirement for high NADPH levels, a major portion of overall H2 production occurs under anoxic conditions in the dark, supported by breakdown of glycogen or other organic substrates accumulated during photosynthesis. Also, other factors, such as N or S limitation, pH changes, presence of other substances, or deletion of particular respiratory components, can affect light or dark H2 production. Therefore, in the first line of inquiry, under a number of culture conditions with wild type (WT) Synechocystis PCC 6803 cells and a mutant with impaired type I NADPH-dehydrogenase (NDH-1) function, we used H2 production profiling and metabolic flux analysis, with and without specific inhibitors, to examine systematically the pathways involved in light and dark H2 production. Results from this work provided rational bases for metabolic engineering to maximize photobiological H2 production on a 24-hour basis. In the second line of inquiry, we used site-directed mutagenesis to create mutants with hydrogenase enzymes exhibiting greater O2 tolerance. The research addressed the following four tasks: 1. Evaluate the effects of various culture conditions (N, S, or P limitation; light/dark; pH; exogenous organic carbon) on H2 production profiles of WT cells and an NDH-1 mutant; 2. Conduct metabolic flux analyses for

  13. Nighttime sleep duration, 24-hour sleep duration and risk of all-cause mortality among adults: a meta-analysis of prospective cohort studies

    PubMed Central

    Shen, Xiaoli; Wu, Yili; Zhang, Dongfeng

    2016-01-01

    A dose-response meta-analysis was conducted to summarize evidence from prospective cohort studies about the association of nighttime sleep duration and 24-hour sleep duration with risk of all-cause mortality among adults. Pertinent studies were identified by a search of Embase and PubMed databases to March 2015. A two-stage random-effects dose–response meta-analysis was used to combine study-specific relative risks and 95% confidence intervals [RRs (95% CIs)]. Thirty-five articles were included. Compared with 7 hours/day, the RRs (95% CIs) of all-cause mortality were 1.07 (1.03–1.13), 1.04 (1.01–1.07), 1.01 (1.00–1.02), 1.07 (1.06–1.09), 1.21 (1.18–1.24), 1.37 (1.32–1.42) and 1.55 (1.47–1.63) for 4, 5, 6, 8, 9, 10 and 11 hours/day of nighttime sleep, respectively (146,830 death cases among 1,526,609 participants), and the risks were 1.09 (1.04–1.14), 1.05 (1.02–1.09), 1.02 (1.00–1.03), 1.08 (1.05–1.10), 1.27 (1.20–1.36), 1.53 (1.38–1.70) and 1.84 (1.59–2.13) for 4, 5, 6, 8, 9, 10 and 11 hours/day of 24-hour sleep, respectively (101,641 death cases among 903,727 participants). The above relationships were also found in subjects without cardiovascular diseases and cancer at baseline, and other covariates did not influence the relationships substantially. The results suggested that 7 hours/day of sleep duration should be recommended to prevent premature death among adults. PMID:26900147

  14. Control of bleeding by silk ligation and diathermy coagulation during tonsillectomy: A comparison of efficacy of the two techniques in the first 24 hours after surgery

    PubMed Central

    Anwar, Khurshid; Ahmad, Rafiq; Khan, Muneeb

    2015-01-01

    Objective: To assess and compare the relative efficacy of silk ligation and diathermy coagulation techniques in controlling bleeding during tonsillectomy in the first 24 hours. Methods: This prospective study was conducted at the Department of ENT, Khalifa Gul Nawaz Teaching Hospital, Bannu and this department related consultants’ private clinics from January 1, 2012 to December 31, 2014. The study included 180 cases. All patients included were having history of recurrent, acute tonsillitis, with more than 6–7 episodes in one year, five episodes per year for two years, or three episodes per year for three years. All the surgeries were performed by dissection method. Haemostasis during the procedure was secured by either ligation with silk 1 or using diathermy. The results were analyzed using SPSS 16.0 for windows. Results: A total of180 cases were included in the study. The ages of the patients ranged from 5 to 40 years with the mean age of 15.56 years and a std.deviation of +/- 8.24. The male to female ratio was 1.25:1. The number of hemorrhages occurring was greater in the ‘diathermy coagulation’ group as compared to the ‘silk ligation’ group. However, the observed difference was statistically insignificant (p >.05). Conclusion: Primary haemorrhage occurring during tonsillectomy is a serious threat and control of bleeding during the procedure should therefore be meticulous. Both suture ligation and coagulation diathermy for control of bleeders during the procedure by dissection method are equally effective. PMID:26430438

  15. Canadian 24-Hour Movement Guidelines for Children and Youth: Exploring the perceptions of stakeholders regarding their acceptability, barriers to uptake, and dissemination.

    PubMed

    Faulkner, Guy; White, Lauren; Riazi, Negin; Latimer-Cheung, Amy E; Tremblay, Mark S

    2016-06-01

    Engaging stakeholders in the development of guidelines and plans for implementation is vital. The purpose of this study was to examine stakeholders' (parents, teachers, exercise professionals, paediatricians, and youth) perceptions of the Canadian 24-Hour Movement Behaviour Guidelines for Children and Youth ("Movement Guidelines"). Stakeholders (n = 104) engaged in semi-structured focus groups or interviews to discuss the perceived acceptability of the guidelines, potential barriers to implementation, and preferred methods and messengers of dissemination. A thematic analysis was conducted. Overall, there was consistent support across all stakeholder groups, with the exception of youth participants, for the Movement Guidelines. Stakeholders identified a range of barriers to the uptake of the guidelines including concerns with accurately defining key terms such as "recreational" screen time; everyday challenges such as financial and time constraints; and the possibility of the Movement Guidelines becoming just another source of stress and guilt for already busy and overwhelmed parents. Participants identified a range of recommended methods and messengers for future dissemination. School and medical settings were the most commonly recommended settings through which dissemination efforts should be delivered. Overall, participants representing a range of stakeholder groups were receptive to the new Movement Guidelines and endorsed their value. In complementing the Movement Guidelines, messaging and resources will need to be developed that address common concerns participants had regarding their dissemination and implementation. PMID:27306436

  16. A Day in the Life of Millisecond Pulsar J1713+0747: Limits on Timing Precision Over 24 Hours and Implications for Gravitational Wave Detection

    NASA Astrophysics Data System (ADS)

    Dolch, Timothy; Bailes, M.; Bassa, C.; Bhat, R.; Bhattacharyya, B.; Champion, D.; Chatterjee, S.; Cognard, I.; Cordes, J. M.; Crowter, K.; Demorest, P.; Finn, L. S.; Fonseca, E.; Hessels, J.; Hobbs, G.; Janssen, G.; Jones, G.; Jordan, C.; Karuppusamy, R.; Keith, M.; Kramer, M.; Kraus, A.; Lam, M. T.; Lazarus, P.; Lazio, J.; Lee, K.; Levin, L.; Liu, K.; Lorimer, D.; Manchester, R. N.; McLaughlin, M.; Palliyaguru, N.; Perrodin, D.; Petroff, E.; Rajwade, K.; Rankin, J. M.; Ransom, S. M.; Rosenblum, J.; Roy, J.; Shannon, R.; Stappers, B.; Stinebring, D.; Stovall, K.; Teixeira, M.; van Leeuwen, J.; van Straten, W.; Verbiest, J.; Zhu, W.

    2014-01-01

    A 24-hour global observation of millisecond radio pulsar J1713+0747 was undertaken by the International Pulsar Timing Array (IPTA) collaboration as an effort to better quantify sources of noise in this object, which is regularly timed for the purpose of detecting gravitational waves (GWs). Given an 8-year timing RMS of 30ns, it is regarded as one of the best precision clocks in the PTA. However, sources of timing noise visible on timescales longer than the usual 20-30min biweekly observation may nonetheless be present. Data from the campaign were taken contiguously with the Parkes, Arecibo, Green Bank, GMRT, LOFAR, Effelsberg, WSRT, Lovell, and Nancay radio telescopes. The combined pulse times-of-arrival provide an estimate of the absolute noise floor, in other words, what unaccounted sources of timing noise impede an otherwise simple sqrt(N) improvement in timing precision, where N is the number of pulses in a single observing session. We present first results of specific phenomena probed on the unusual timescale of tens of hours, in particular interstellar scattering (ISS), and discuss the degree to which ISS affects precision timing. Finally, we examine single pulse information during selected portions of the observation and determine the degree to which the pulse jitter of J1713+0747 varies throughout the course of the day-long dataset.

  17. Age-dependent changes in 24-hour rhythms of catecholamine content and turnover in hypothalamus, corpus striatum and pituitary gland of rats injected with Freund's adjuvant

    PubMed Central

    Cano, Pilar; Cardinali, Daniel P; Chacon, Fernando; Castrillón, Patricia O; Reyes Toso, Carlos A; Esquifino, Ana I

    2001-01-01

    Background Little information is available on the circadian sequela of an immune challenge in the brain of aged rats. To assess them, we studied 24-hour rhythms in hypothalamic and striatal norepinephrine (NE) content, hypothalamic and striatal dopamine (DA) turnover and hypophysial NE and DA content, in young (2 months) and aged (18–20 months) rats killed at 6 different time intervals, on day 18th after Freund's adjuvant or adjuvant's vehicle administration. Results Aging decreased anterior and medial hypothalamic NE content, medial and posterior hypothalamic DA turnover, and striatal NE concentration and DA turnover. Aging also decreased NE and DA content in pituitary neurointermediate lobe and augmented DA content in the anterior pituitary lobe. Immunization by Freund's adjuvant injection caused: (i) reduction of DA turnover in anterior hypothalamus and corpus striatum; (ii) acrophase delay of medial hypothalamic DA turnover in old rats, and of striatal NE content in young rats; (iii) abolition of 24-h rhythm in NE and DA content of neurointermediate pituitary lobe, and in DA content of anterior lobe, of old rats. Conclusions The decline in catecholamine neurotransmission with aging could contribute to the decrease of gonadotropin and increase of prolactin release reported in similar groups of rats. Some circadian responses to immunization, e.g. suppression of 24-h rhythms of neurointermediate lobe NE and DA and of anterior lobe DA were seen only in aged rats. PMID:11741510

  18. Computer simulation of the effect of dDAVP with saline loading on fluid balance after 24-hour head-down tilt

    NASA Technical Reports Server (NTRS)

    Srinivasan, R. S.; Simanonok, K. E.; Charles, J. B.

    1994-01-01

    Fluid loading (FL) before Shuttle reentry is a countermeasure currently in use by NASA to improve the orthostatic tolerance of astronauts during reentry and postflight. The fluid load consists of water and salt tablets equivalent to 32 oz (946 ml) of isotonic saline. However, the effectiveness of this countermeasure has been observed to decrease with the duration of spaceflight. The countermeasure's effectiveness may be improved by enhancing fluid retention using analogs of vasopressin such as lypressin (LVP) and desmopressin (dDAVP). In a computer simulation study reported previously, we attempted to assess the improvement in fluid retention obtained by the use of LVP administered before FL. The present study is concerned with the use of dDAVP. In a recent 24-hour, 6 degree head-down tilt (HDT) study involving seven men, dDAVP was found to improve orthostatic tolerance as assessed by both lower body negative pressure (LBNP) and stand tests. The treatment restored Luft's cumulative stress index (cumulative product of magnitude and duration of LBNP) to nearly pre-bedrest level. The heart rate was lower and stroke volume was marginally higher at the same LBNP levels with administration of dDAVP compared to placebo. Lower heart rates were also observed with dDAVP during stand test, despite the lower level of cardiovascular stress. These improvements were seen with only a small but significant increase in plasma volume of approximately 3 percent. This paper presents a computer simulation analysis of some of the results of this HDT study.

  19. "2001: A Space Odyssey" Revisited--The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    1998-01-01

    The prospects for "24 hour" commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, "high leverage" technologies--liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Ironrich volcanic glass, or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way, LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging front the engine's choked sonic throat--essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  20. 2001: A Space Odyssey Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley; Dudzinski, Leonard A.

    2003-01-01

    The prospects for 24 hour commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, high leverage technologies: liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and lunar-derived oxygen (LUNOX) production. Iron-rich volcanic glass, or orange soil, discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4 percent oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an afterburner into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat, essentially scramjet propulsion in reverse. By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that big engine performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or in-line Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an expendable mode initially, to maximize delivered surface payload on each mission. The increased payload is

  1. "2001: A Space Odyssey" Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    2001-01-01

    The prospects for "24 hour" commuter flights to the Moon. similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale. are examined using two near term. "high leverage" technologies-liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Iron-rich volcanic glass. or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow. has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat-essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller. more affordable. easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  2. Epidemiology of Urban Traffic Accident Victims Hospitalized More Than 24 Hours in a Level III Trauma Center, Kashan County, Iran, During 2012-2013

    PubMed Central

    Mahdian, Mehrdad; Sehat, Mojtaba; Fazel, Mohammad Reza; Moraveji, Alireza; Mohammadzadeh, Mahdi

    2015-01-01

    Background: Urban traffic accidents are an extensively significant problem in small and busy towns in Iran. This study tried to explore the epidemiological pattern of urban traffic accidents in Kashan and Aran-Bidgol cities, Iran. Objectives: This study aimed to assess various epidemiological factors affecting victims of trauma admitted to a main trauma center in Iran. Patients and Methods: During a retrospective study, data including age, sex, injury type and pattern, outcome, hospital stay and treatment expenditures regarding urban Road Traffic Accidents (RTAs) for one year (March 2012-March 2013) were obtained from the registry of trauma research center, emergency medical services and deputy of health of Kashan University of Medical Sciences. One-way ANOVA and chi-square tests were used to analyze data using SPSS version 16.0. P value < 0.05 was considered significant. Results: A total of 1723 victims (82.6% male, sex ratio of almost 5:1) were considered in this study. Mortality rate in trauma cases hospitalized more than 24 hours during our study was 0.8%. Young motorcyclist men with the rate of more than 103 per 10000 were the most vulnerable group. The most common injury was head injury (73.6%) followed by lower limb injury (33.2%). A significant association was found between mechanism of injury and head, lower limb, multiple injuries and high risk age group. Conclusions: Urban RTAs are one of the most important problems in Kashan and Aran-Bidgol cities, which impose a great economic burden on health system. Motorcyclists are the most vulnerable victims and multiple trauma and head injury are seen among them extensively. PMID:26101765

  3. Self-Reported Sleep Disturbance is associated with Lower CD4 Count and 24-Hour Urinary Dopamine Levels in Ethnic Minority Women Living with HIV

    PubMed Central

    Seay, Julia S.; McIntosh, Roger; Fekete, Erin M.; Fletcher, Mary Ann; Kumar, Mahendra; Schneiderman, Neil; Antoni, Michael H.

    2013-01-01

    Background Sleep disturbance is associated with dopamine dysregulation, which can negatively impact immune status. Individuals living with HIV experience more sleep difficulties, and poor sleep may compound immune decrements associated with HIV infection. Little research has examined associations between sleep, dopamine, and immune status (CD4 count) in individuals with HIV. As ethnic minority women living with HIV (WLWH) are at heightened risk for HIV disease progression, we related sleep reports to both CD4 count and dopamine levels in a cohort of ethnic minority WLWH. Methods Participants were 139 low-income WLWH (ages 20–62; 78.3% African-American or Caribbean) who reported both overall sleep quality and sleep disturbance on the Pittsburgh Sleep Quality Index (PSQI). CD4 count and HIV viral load were measured via morning peripheral venous blood samples, and concentrations of dopamine were measured via 24-hour urine collection. Covariates included HIV viral load, length of time since HIV diagnosis, HAART adherence, perceived stress and depression. Results After controlling for all covariates, greater sleep disturbance was associated with significantly lower CD4 count (β = −.20, p = .03) and lower levels of dopamine (β = −.25, p = .04). Poorer overall sleep quality was marginally associated with lower CD4 count (β = −.16, p = .08), and was not associated with dopamine. Conclusion Our analyses suggest that sleep disturbance is independently related with immune status and dopamine levels in WLWH. Lower levels of dopamine may indicate neuroendocrine dysregulation and may impact immune and health status. Results highlight sleep disturbance rather than overall sleep quality as potentially salient to neuroendocrine and immune status in ethnic minority WLWH. PMID:23850225

  4. Establishing normal plasma and 24-hour urinary biochemistry ranges in C3H, BALB/c and C57BL/6J mice following acclimatization in metabolic cages.

    PubMed

    Stechman, Michael J; Ahmad, Bushra N; Loh, Nellie Y; Reed, Anita A C; Stewart, Michelle; Wells, Sara; Hough, Tertius; Bentley, Liz; Cox, Roger D; Brown, Steve D M; Thakker, Rajesh V

    2010-07-01

    Physiological studies of mice are facilitated by normal plasma and 24-hour urinary reference ranges, but variability of these parameters may increase due to stress that is induced by housing in metabolic cages. We assessed daily weight, food and water intake, urine volume and final day measurements of the following: plasma sodium, potassium, chloride, urea, creatinine, calcium, phosphate, alkaline phosphatase, albumin, cholesterol and glucose; and urinary sodium, potassium, calcium, phosphate, glucose and protein in 24- to 30-week-old C3H/HeH, BALB/cAnNCrl and C57BL/6J mice. Between 15 and 20 mice of each sex from all three strains were individually housed in metabolic cages with ad libitum feeding for up to seven days. Acclimatization was evaluated using general linear modelling for repeated measures and comparison of biochemical data was by unpaired t-test and analysis of variance (SPSS version 12.0.1). Following an initial 5-10% fall in body weight, daily dietary intake, urinary output and weight in all three strains reached stable values after 3-4 days of confinement. Significant differences in plasma glucose, cholesterol, urea, chloride, calcium and albumin, and urinary glucose, sodium, phosphate, calcium and protein were observed between strains and genders. Thus, these results provide normal reference values for plasma and urinary biochemistry in three strains housed in metabolic cages and demonstrate that 3-4 days are required to reach equilibrium in metabolic cage studies. These variations due to strain and gender have significant implications for selecting the appropriate strain upon which to breed genetically-altered models of metabolic and renal disease.

  5. Effects of Potassium Magnesium Citrate Supplementation on 24-Hour Ambulatory Blood Pressure and Oxidative Stress Marker in Prehypertensive and Hypertensive Subjects.

    PubMed

    Vongpatanasin, Wanpen; Peri-Okonny, Poghni; Velasco, Alejandro; Arbique, Debbie; Wang, Zhongyun; Ravikumar, Priya; Adams-Huet, Beverly; Moe, Orson W; Pak, Charles Y C

    2016-09-15

    Diet rich in fruits, vegetables, and dairy products, known as the Dietary Approaches to Stop Hypertension (DASH) diet, is known to reduce blood pressure (BP) in hypertensive patients. More recently, the DASH diet was shown to reduce oxidative stress in hypertensive and nonhypertensive humans. However, the main nutritional components responsible for these beneficial effects of the DASH diet remain unknown. Because the DASH diet is rich in potassium (K), magnesium (Mg), and alkali, we performed a randomized, double-blinded, placebo-controlled study to compare effects of potassium magnesium citrate (KMgCit), potassium chloride (KCl), and potassium citrate (KCit) to allow dissociation of the three components of K, Mg, and citrate on 24-hour ambulatory BP and urinary 8-isoprostane in hypertensive and prehypertensive subjects, using a randomized crossover design. We found that KCl supplementation for 4 weeks induced a significant reduction in nighttime SBP compared with placebo (116 ± 12 vs 121 ± 15 mm Hg, respectively, p <0.01 vs placebo), whereas KMgCit and KCit had no significant effect in the same subjects (118 ± 11 and 119 ± 13 mm Hg, respectively, p >0.1 vs placebo). In contrast, urinary 8-isoprostane was significantly reduced with KMgCit powder compared with placebo (13.5 ± 5.7 vs 21.1 ± 10.5 ng/mgCr, respectively, p <0.001), whereas KCl and KCit had no effect (21.4 ± 9.1 and 18.3 ± 8.4, respectively, p >0.1 vs placebo). In conclusion, our study demonstrated differential effects of KCl and KMgCit supplementation on BP and the oxidative stress marker in prehypertensive and hypertensive subjects. Clinical significance of the antioxidative effect of KMgCit remains to be determined in future studies. PMID:27448942

  6. Evidence for Long-period (14-30 Days) and Against Short-period (12-24 Hours) Tidal Modulation of Volcanic Tremor at Arenal Volcano, Costa Rica

    NASA Astrophysics Data System (ADS)

    Hagerty, M. T.; Schwartz, S.; Revenaugh, J.

    2008-12-01

    Many studies have sought a correlation between the occurrence of earthquakes or volcanic activity and various Earth tide components, which would provide evidence for external tidal modulation of these geophysical phenomena. Several studies of short duration seismic experiments at Arenal Volcano in Costa Rica have found evidence of diurnal and semi-diurnal tidal periodicities in the seismic record. However, studies at other volcanoes, using longer time series, with improved spectral resolution, do not find tidal peaks in the seismic spectrum, but rather solar peaks (at exactly 12 and/or 24 hours), suggesting that the modulation is caused not by tidal stresses, but by weather related parameters - temperature, barometric pressure, rainfall. In contrast, recent studies of nonvolcanic tremor in the subduction zones of Japan and Cascadia do find evidence for tidal modulation of tremor activity with a period of 12.4 hours. Thus, the questions of whether or not earthquakes and volcanoes are triggered by external forces, and if so, whether these forces are related to elastic tides or to weather, are still highly relevant. We examine a continuous, 302-day long recording of ground motion at Arenal Volcano, Costa Rica, for potential solar and lunar periodicities in the volcanic seismicity. No evidence is found for significant energy in the semidiurnal (near 12 hr) or diurnal (near 24 hr) frequency bands, in contrast to previous, lower- resolution studies at Arenal. However, analysis with multi-taper method (MTM) and singular spectrum analysis (SSA) reveals significant low-frequency (f < .005 cycles/hr) energy in the tremor and explosivity series, including 14 and 30-day quasi-periodic components, relative to a red noise hypothesis. We attempt to fit the data to long-period tidal frequencies in order to verify potential tidal modulation of the long-period seismic energy at Arenal.

  7. Effect of melatonin on 24-hour rhythms of ornithine decarboxylase activity and norepinephrine and acetylcholine synthesis in submaxillary lymph nodes and spleen of young and aged rats.

    PubMed

    Cardinali, D P; Brusco, L I; García Bonacho, M; Esquifìno, A I

    1998-05-01

    Young (50 days old) and old (18 months old) Sprague-Dawley rats were injected with mycobacterial Freund's adjuvant to produce an inflammatory disease of the joints and were studied the day before, and on days 6, 12 and 18 after injection. At every postinjection interval examined, old rats had significantly lower circadian amplitudes of pineal melatonin content. On day 18 of arthritis development, decreased levels of pineal melatonin were also seen in young rats. A second study, carried out 18 days after the injection of Freund's complete adjuvant and after 17 daily injections of 10 or 100 microg of melatonin in the evening, indicated that melatonin treatment restored the inflammatory response in old rats (assessed plethysmographically in hind paws) to the level found in young animals. In young rats, an inflammation-promoting effect of 100 microg melatonin could be demonstrated. As a consequence of the immune reaction, submaxillary lymph node and splenic ornithine decarboxylase activity (an index of lymph cell proliferation) augmented significantly, with acrophases of 24-hour rhythms in the afternoon for lymph nodes or in the morning for spleen. Mesor and amplitude of ornithine decarboxylase rhythm were lowest in old rats, while melatonin injection generally augmented its amplitude. Lymph node and splenic tyrosine hydroxylase activity (a presynaptic adrenergic marker) reached maximal values during early night hours while maximal values of [3H]acetylcholine synthesis (a presynaptic cholinergic marker) occurred during the afternoon in lymph nodes. Amplitude and mesor of these rhythms were lowest in old rats, an effect generally counteracted by melatonin treatment. The results suggest that inflammation is accompanied by an age-dependent, significant depression of pineal melatonin synthesis during adjuvant-induced arthritis and a decreased amplitude of the circadian rhythm of immune cell proliferation and autonomic activity in lymph nodes and spleen. These effects are

  8. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs

    PubMed Central

    Hodkinson, Emily C.; Neijts, Melanie; Sadrieh, Arash; Imtiaz, Mohammad S.; Baumert, Mathias; Subbiah, Rajesh N.; Hayward, Christopher S.; Boomsma, Dorret; Willemsen, Gonneke; Vandenberg, Jamie I.; Hill, Adam P.; De Geus, Eco

    2016-01-01

    Introduction: The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. Methods and Results: Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters. Conclusions: Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic—environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease. PMID:27199769

  9. Sex and age-related differences in performance in a 24-hour ultra-cycling draft-legal event – a cross-sectional data analysis

    PubMed Central

    2014-01-01

    Background The purpose of this study was to examine the sex and age-related differences in performance in a draft-legal ultra-cycling event. Methods Age-related changes in performance across years were investigated in the 24-hour draft-legal cycling event held in Schötz, Switzerland, between 2000 and 2011 using multi-level regression analyses including age, repeated participation and environmental temperatures as co-variables. Results For all finishers, the age of peak cycling performance decreased significantly (β = −0.273, p = 0.036) from 38 ± 10 to 35 ± 6 years in females but remained unchanged (β = −0.035, p = 0.906) at 41.0 ± 10.3 years in males. For the annual fastest females and males, the age of peak cycling performance remained unchanged at 37.3 ± 8.5 and 38.3 ± 5.4 years, respectively. For all female and male finishers, males improved significantly (β = 7.010, p = 0.006) the cycling distance from 497.8 ± 219.6 km to 546.7 ± 205.0 km whereas females (β = −0.085, p = 0.987) showed an unchanged performance of 593.7 ± 132.3 km. The mean cycling distance achieved by the male winners of 960.5 ± 51.9 km was significantly (p < 0.001) greater than the distance covered by the female winners with 769.7 ± 65.7 km but was not different between the sexes (p > 0.05). The sex difference in performance for the annual winners of 19.7 ± 7.8% remained unchanged across years (p > 0.05). The achieved cycling distance decreased in a curvilinear manner with advancing age. There was a significant age effect (F = 28.4, p < 0.0001) for cycling performance where the fastest cyclists were in age group 35–39 years. Conclusion In this 24-h cycling draft-legal event, performance in females remained unchanged while their age of peak cycling performance decreased and performance in males improved while their age of peak cycling performance remained unchanged. The annual fastest females and males were 37.3 ± 8.5 and 38.3 ± 5.4 years old, respectively. The sex

  10. The Telemetric and Holter ECG Warehouse (THEW): the first three years of development and research.

    PubMed

    Couderc, Jean-Philippe

    2012-01-01

    The Telemetric and Holter ECG Warehouse (THEW) hosts more than 3700 digital 24-Holter ECG recordings from 13 independent studies. In addition to the ECGs, the repository includes patient information in separate clinical database with content varying according to the study focus. In its third year of activities, the THEW database has been accessed by researchers from 37 universities and 16 corporations located in 16 countries worldwide. Twenty publications were released primarily focusing on the development and validation of ECG-based technologies. This communication describes the content of the databases of the repository with brief summary of the research and development projects completed using these data.

  11. Towards a smart Holter system with high performance analogue front-end and enhanced digital processing.

    PubMed

    Du, Leilei; Yan, Yan; Wu, Wenxian; Mei, Qiujun; Luo, Yu; Li, Yang; Wang, Lei

    2013-01-01

    Multiple-lead dynamic ECG recorders (Holter) play an important role in the earlier detection of various cardiovascular diseases. In this paper, we present the first several steps towards a 12-lead Holter system with high-performance AFE (Analogue Front-End) and enhanced digital processing. The system incorporates an analogue front-end chip (ADS1298 from TI), which has not yet been widely used in most commercial Holter products. A highly-efficient data management module was designated to handle the data exchange between the ADS1298 and the microprocessor (STM32L151 from ST electronics). Furthermore, the system employs a Field Programmable Gate Array (Spartan-3E from Xilinx) module, on which a dedicated real-time 227-step FIR filter was executed to improve the overall filtering performance, since the ADS1298 has no high-pass filtering capability and only allows limited low-pass filtering. The Spartan-3E FPGA is also capable of offering further on-board computational ability for a smarter Holter. The results indicate that all functional blocks work as intended. In the future, we will conduct clinical trials and compare our system with other state-of-the-arts.

  12. The evolution of ambulatory ECG monitoring.

    PubMed

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health. PMID:24215744

  13. [Practical value of the detection of silent myocardial ischemia in patients with coronary disease using Holters].

    PubMed

    Jan, F; Monin, J L; Leichter, S; Pochmalicki, G

    1994-02-01

    The prognosis of painless myocardial ischemia is similar to that of symptomatic ischemia. The Holter technique (and solid memory Holter in particular) is a simple method of detection which, taken together with exercise testing, enables the identification among coronary disease patients of a high risk group in whom effort ischemia is accompanied by episodes of ischemia under everyday conditions and in whom additional investigations (exercise thallium scan then coronary arteriography) and appropriate treatment, including transluminal angioplasty and aorto-coronary bypass if necessary, may be required. The role of drug treatment in silent ischemia has not yet been clearly defined. While electrical ischemia regresses significantly with the majority of standard drug regimens, and beta-blockers in particular, none has yet been confirmed as having a preventive effect against serious events following on from silent myocardial ischemia.

  14. Using statistical distances to detect changes in the normal behavior of ECG-Holter signals

    NASA Astrophysics Data System (ADS)

    Bastos de Figueiredo, Julio C.; Furuie, Sergio S.

    2001-05-01

    One of the main problems in the study of complex systems is to define a good metric that can distinguish between different dynamical behaviors in a nonlinear system. In this work we describe a method to detect different types of behaviors in a long term ECG-Holter using short portions of the Holter signal. This method is based on the calculation of the statistical distance between two distributions in a phase-space of a dynamical system. A short portion of an ECG-Holter signal with normal behavior is used to reconstruct the trajectory of an attractor in low dimensional phase-space. The points in this trajectory are interpreted as statistical distributions in the phase-space and assumed to represent the normal dynamical behavior of the ECG recording in this space. A fast algorithm is then used to compute the statistical distance between this attractor and all other attractors that are built using a sliding temporal window over the signal. For normal cases the distance stayed almost constant and below a threshold. For cases with abnormal transients, on the abnormal portion of ECG, the distance increased consistently with morphological changes.

  15. Estimating the Population Distribution of Usual 24-Hour Sodium Excretion from Timed Urine Void Specimens Using a Statistical Approach Accounting for Correlated Measurement Errors1234

    PubMed Central

    Wang, Chia-Yih; Carriquiry, Alicia L; Chen, Te-Ching; Loria, Catherine M; Pfeiffer, Christine M; Liu, Kiang; Sempos, Christopher T; Perrine, Cria G; Cogswell, Mary E

    2015-01-01

    Background: High US sodium intake and national reduction efforts necessitate developing a feasible and valid monitoring method across the distribution of low-to-high sodium intake. Objective: We examined a statistical approach using timed urine voids to estimate the population distribution of usual 24-h sodium excretion. Methods: A sample of 407 adults, aged 18–39 y (54% female, 48% black), collected each void in a separate container for 24 h; 133 repeated the procedure 4–11 d later. Four timed voids (morning, afternoon, evening, overnight) were selected from each 24-h collection. We developed gender-specific equations to calibrate total sodium excreted in each of the one-void (e.g., morning) and combined two-void (e.g., morning + afternoon) urines to 24-h sodium excretion. The calibrated sodium excretions were used to estimate the population distribution of usual 24-h sodium excretion. Participants were then randomly assigned to modeling (n = 160) or validation (n = 247) groups to examine the bias in estimated population percentiles. Results: Median bias in predicting selected percentiles (5th, 25th, 50th, 75th, 95th) of usual 24-h sodium excretion with one-void urines ranged from −367 to 284 mg (−7.7 to 12.2% of the observed usual excretions) for men and −604 to 486 mg (−14.6 to 23.7%) for women, and with two-void urines from −338 to 263 mg (−6.9 to 10.4%) and −166 to 153 mg (−4.1 to 8.1%), respectively. Four of the 6 two-void urine combinations produced no significant bias in predicting selected percentiles. Conclusions: Our approach to estimate the population usual 24-h sodium excretion, which uses calibrated timed-void sodium to account for day-to-day variation and covariance between measurement errors, produced percentile estimates with relatively low biases across low-to-high sodium excretions. This may provide a low-burden, low-cost alternative to 24-h collections in monitoring population sodium intake among healthy young adults and

  16. Urinary excretion of sodium, potassium, and chloride, but not iodine, varies by timing of collection in a 24-hour calibration study.

    PubMed

    Wang, Chia-Yih; Cogswell, Mary E; Loria, Catherine M; Chen, Te-Ching; Pfeiffer, Christine M; Swanson, Christine A; Caldwell, Kathleen L; Perrine, Cria G; Carriquiry, Alicia L; Liu, Kiang; Sempos, Christopher T; Gillespie, Cathleen D; Burt, Vicki L

    2013-08-01

    Because of the logistic complexity, excessive respondent burden, and high cost of conducting 24-h urine collections in a national survey, alternative strategies to monitor sodium intake at the population level need to be evaluated. We conducted a calibration study to assess the ability to characterize sodium intake from timed-spot urine samples calibrated to a 24-h urine collection. In this report, we described the overall design and basic results of the study. Adults aged 18-39 y were recruited to collect urine for a 24-h period, placing each void in a separate container. Four timed-spot specimens (morning, afternoon, evening, and overnight) and the 24-h collection were analyzed for sodium, potassium, chloride, creatinine, and iodine. Of 481 eligible persons, 407 (54% female, 48% black) completed a 24-h urine collection. A subsample (n = 133) collected a second 24-h urine 4-11 d later. Mean sodium excretion was 3.54 ± 1.51 g/d for males and 3.09 ± 1.26 g/d for females. Sensitivity analysis excluding those who did not meet the expected creatinine excretion criterion showed the same results. Day-to-day variability for sodium, potassium, chloride, and iodine was observed among those collecting two 24-h urine samples (CV = 16-29% for 24-h urine samples and 21-41% for timed-spot specimens). Among all race-gender groups, overnight specimens had larger volumes (P < 0.01) and lower sodium (P < 0.01 to P = 0.26), potassium (P < 0.01), and chloride (P < 0.01) concentrations compared with other timed-spot urine samples, although the differences were not always significant. Urine creatinine and iodine concentrations did not differ by the timing of collection. The observed day-to-day and diurnal variations in sodium excretion illustrate the importance of accounting for these factors when developing calibration equations from this study.

  17. Investigation of cattle methane production and emission over a 24-hour period using measurements of δ13C and δD of emitted CH4 and rumen water

    NASA Astrophysics Data System (ADS)

    Bilek, R. S.; Tyler, S. C.; Kurihara, M.; Yagi, K.

    2001-07-01

    We have conducted a series of experiments to determine the effects different diets, including the addition of unsaturated fatty acids, had on isotopic signatures of CH4 emissions from dairy cattle. Measurements of emitted δ13CH4, δ13CO2, and δD-CH4 were made on gases collected over a 24-hour period from animal chambers containing individual Holstein cows. Some measurements of δD-H2O from samples collected directly from the rumen were also made. We observed variation in δ13CH4 values with time after feeding and a correlation in δ13C between emitted gases and diet. The average δ13CH4 value, which includes all samples of emitted gases, was -70.6±4.9‰ (n = 57). Measurements of δD-CH4 over the 24-hour sampling period had an average value of -357.8±15.0‰ (n = 56). These δD measurements are among the lightest reported for CH4 produced by cattle. Our cattle data indicate that hydrogen incorporated into the CH4 produced by CO2 reduction in high H2 concentration environments is fractionated to a greater degree than that incorporated in systems with relatively low H2 conditions, such as wetlands. Our results support bacterial studies that have demonstrated large hydrogen fractionation in high H2 concentration systems during methanogenesis.

  18. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy

    PubMed Central

    Akintola, Abimbola A.; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C.; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93–56.45%) and within (range 0.75–9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was −2.8, −1.0, and −0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed

  19. FREQUENCY DISTRIBUTIONS AND SPATIAL ANALYSIS OF FINE PARTICLE MEASUREMENTS IN ST. LOUIS DURING THE REGIONAL AIR POLLUTION STUDY/REGIONAL AIR MONITORING SYSTEM

    EPA Science Inventory

    Community, time-series epidemiology typically uses either 24-hour integrated particulate matter (PM) concentrations averaged across several monitors in a city or data obtained at a central monitoring site to relate PM concentrations to human health effects. If 24-hour integrated...

  20. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Gruber HA, Farag AF. Evaluation of endocrine function. In: McPherson RA, Pincus MR, eds. Henry's Clinical Diagnosis and Management by Laboratory Methods . 22nd ed. Philadelphia, PA: Elsevier Saunders; 2011:chap 24.

  1. Toys Remain Viral Playground for 24 Hours

    MedlinePlus

    ... a toy's surface at typical indoor temperatures and humidity levels. Specifically, they tested the ability of so- ... East Respiratory Syndrome (MERS). At 60 percent relative humidity, 1 percent of the virus remained infectious on ...

  2. Advances in ambulatory monitoring: regulatory considerations.

    PubMed

    Buckles, David; Aguel, Felipe; Brockman, Randall; Cheng, James; Demian, Cindy; Ho, Charles; Jensen, Donald; Mallis, Elias

    2004-01-01

    Conventional ambulatory electrocardiogram (ECG) (Holter) monitoring involves 2 or 3 surface leads recorded with electrode positions and signal characteristics that are different from diagnostic quality 12-lead ECGs due to the limitations imposed by technology on the ambulatory recorders. The rapid pace of technological development for medical devices, particularly electrocardiography, has now enabled the recording of diagnostic quality 12-lead ECG waveforms for extended time periods. This capability allows Holter recording to become another source for diagnostic 12-lead ECG records on a par with other modalities such as resting ECG and exercise stress testing. Additionally, other diagnostic techniques such as S-T segment analysis and Q-T interval analysis that rely on diagnostic quality waveforms can now be applied. All of these enhancements to the traditional Holter modality have altered the regulatory perspective of these devices, since the enhancements may represent a new intended use for the device.

  3. Advances in ambulatory monitoring: regulatory considerations.

    PubMed

    Buckles, David; Aguel, Felipe; Brockman, Randall; Cheng, James; Demian, Cindy; Ho, Charles; Jensen, Donald; Mallis, Elias

    2004-01-01

    Conventional ambulatory electrocardiogram (ECG) (Holter) monitoring involves 2 or 3 surface leads recorded with electrode positions and signal characteristics that are different from diagnostic quality 12-lead ECGs due to the limitations imposed by technology on the ambulatory recorders. The rapid pace of technological development for medical devices, particularly electrocardiography, has now enabled the recording of diagnostic quality 12-lead ECG waveforms for extended time periods. This capability allows Holter recording to become another source for diagnostic 12-lead ECG records on a par with other modalities such as resting ECG and exercise stress testing. Additionally, other diagnostic techniques such as S-T segment analysis and Q-T interval analysis that rely on diagnostic quality waveforms can now be applied. All of these enhancements to the traditional Holter modality have altered the regulatory perspective of these devices, since the enhancements may represent a new intended use for the device. PMID:15534803

  4. The Relationship of the Increase in the 'Time of the Earth Day,' from 18 Hours to 24 Hours, to the Increase in the Size of the Earth, Using the Laws of the Conservation of Momentum

    NASA Astrophysics Data System (ADS)

    Cimorelli, S. A.; Samuels, C.

    2010-12-01

    There are three articles, by others, which discuss the increase in the Earth's day, from 18 hours to 24 hours, over a period of time of about a billion years. One article refers to Striations in the Substructure of Coral, C.T. Scrutton, et al, 1965. Another article refers to the Laws of the Conservation of Momentum, as related to the relationship of the Earth and the Moon, the lunar tides, the reduction of the Earth year from 481 days to our present 365.25 days, and an increase in the lunar orbit time from 20 days to 28 days. The third article is based on the dates of tidal sediment deposits, tidalites, C. P. Sonett, et al, in the late 1980's. In this paper, we explain how the Earth's Day could have increased from 18 hours to 24 hours, as related to the Laws of Conservation of Momentum (L). Wherein we use the simple formulation from the Law of the Conservation of Angular Momentum, L=Iω, in which I=Moment of Inertia and ω=Angular Velocity; for which we assume the earth to be a perfect sphere, for which I=0.4MR2, where M and R are the Mass and radius of the earth, respectively. We evaluate the radius of the earth over a time period of several billion years, during which time the earth's angular momentum, L=Iω, is conserved. In this formulation, we show a growth in the size of the earth; and present a curve, using just three points in time, which indicates that the rate of growth is increasing over time. The first point is from about 4.5 billion years ago, the second point is from about 1 billion years ago, and the third point represents present day, with an average growth of about 1mm per year. Although evidence has been presented, by others, showing circumferential growth at the Red Sea and in the Atlantic Ocean, at about 1.5cm per year, total. However, no proof of reduction in the size of the Earth has been shown to occur in the Pacific, or anywhere else, including in references to subduction. Some might say that the subduction is occurring at the rim of the

  5. Effective cross-over to granisetron after failure to ondansetron, a randomized double blind study in patients failing ondansetron plus dexamethasone during the first 24 hours following highly emetogenic chemotherapy

    PubMed Central

    de Wit, R; de Boer, A C; vd Linden, G H M; Stoter, G; Sparreboom, A; Verweij, J

    2001-01-01

    In view of the similarity in chemical structure of the available 5HT3-receptor antagonists it is assumed, whilst these agents all act at the same receptor, that failure to one agent would predict subsequent failure to all 5HT3-receptor antagonists. We conducted a randomized double blind trial of granisetron 3 mg plus dexamethasone 10 mg versus continued treatment with ondansetron 8 mg plus dexamethasone 10 mg in patients with protection failure on ondansetron 8 mg plus dexamethasone 10 mg during the first 24 hours following highly emetogenic chemotherapy. Of 40 eligible patients, 21 received ondansetron + dexamethasone and 19 received granisetron + dexamethasone. We found a significant benefit from crossing-over to granisetron after failure on ondansetron. Of the 19 patients who crossed over to granisetron, 9 patients obtained complete protection, whereas this was observed in 1 of the 21 patients continuing ondansetron, P = 0.005. These results indicate that there is no complete cross-resistance between 5HT3-receptor antagonists, and that patients who have acute protection failure on one 5HT3-receptor antagonist should be offered cross-over to another 5HT3-receptor antagonist. © 2001 Cancer Research Campaign  http://www.bjcancer.com PMID:11710819

  6. Comparison of validity of food group intake by food frequency questionnaire between pre- and post- adjustment estimates derived from 2-day 24-hour recalls in combination with the probability of consumption.

    PubMed

    Kim, Dong Woo; Oh, Se-Young; Kwon, Sung-Ok; Kim, Jeongseon

    2012-01-01

    Validation of a food frequency questionnaire (FFQ) utilising a short-term measurement method is challenging when the reference method does not accurately reflect the usual food intake. In addition, food group intake that is not consumed on daily basis is more critical when episodically consumed foods are related and compared. To overcome these challenges, several statistical approaches have been developed to determine usual food intake distributions. The Multiple Source Method (MSM) can calculate the usual food intake by combining the frequency questions of an FFQ with the short-term food intake amount data. In this study, we applied the MSM to estimate the usual food group intake and evaluate the validity of an FFQ with a group of 333 Korean children (aged 3-6 y) who completed two 24-hour recalls (24HR) and one FFQ in 2010. After adjusting the data using the MSM procedure, the true rate of non-consumption for all food groups was less than 1% except for the beans group. The median Spearman correlation coefficients against FFQ of the mean of 2-d 24HRs data and the MSM-adjusted data were 0.20 (range: 0.11 to 0.40) and 0.35 (range: 0.14 to 0.60), respectively. The weighted kappa values against FFQ ranged from 0.08 to 0.25 for the mean of 2-d 24HRs data and from 0.10 to 0.41 for the MSM-adjusted data. For most food groups, the MSM-adjusted data showed relatively stronger correlations against FFQ than raw 2-d 24HRs data, from 0.03 (beverages) to 0.34 (mushrooms). The results of this study indicated that the application of the MSM, which was a better estimate of the usual intake, could be worth considering in FFQ validation studies among Korean children.

  7. Development of an algorithm for heartbeats detection and classification in Holter records based on temporal and morphological features

    NASA Astrophysics Data System (ADS)

    García, A.; Romano, H.; Laciar, E.; Correa, R.

    2011-12-01

    In this work a detection and classification algorithm for heartbeats analysis in Holter records was developed. First, a QRS complexes detector was implemented and their temporal and morphological characteristics were extracted. A vector was built with these features; this vector is the input of the classification module, based on discriminant analysis. The beats were classified in three groups: Premature Ventricular Contraction beat (PVC), Atrial Premature Contraction beat (APC) and Normal Beat (NB). These beat categories represent the most important groups of commercial Holter systems. The developed algorithms were evaluated in 76 ECG records of two validated open-access databases "arrhythmias MIT BIH database" and "MIT BIH supraventricular arrhythmias database". A total of 166343 beats were detected and analyzed, where the QRS detection algorithm provides a sensitivity of 99.69 % and a positive predictive value of 99.84 %. The classification stage gives sensitivities of 97.17% for NB, 97.67% for PCV and 92.78% for APC.

  8. 50 CFR 217.85 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (301-427-8400), within 24 hours of the discovery of the injured or dead animal. (b) Holders of Letters... conducted 30 minutes before missions to clear the mitigation-monitoring zone. Post-mission monitoring shall... the test site). If marine mammals are inside the mitigation-monitoring zone, detonations shall...

  9. 50 CFR 217.85 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (301-427-8400), within 24 hours of the discovery of the injured or dead animal. (b) Holders of Letters... conducted 30 minutes before missions to clear the mitigation-monitoring zone. Post-mission monitoring shall... the test site). If marine mammals are inside the mitigation-monitoring zone, detonations shall...

  10. 50 CFR 217.85 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (301-427-8400), within 24 hours of the discovery of the injured or dead animal. (b) Holders of Letters... conducted 30 minutes before missions to clear the mitigation-monitoring zone. Post-mission monitoring shall... the test site). If marine mammals are inside the mitigation-monitoring zone, detonations shall...

  11. Microprocessor-Based Ambulatory ECG Monitoring System

    PubMed Central

    Le-Huy, P.; L'Huillier, J.P.; Oumerzouk, Y.; Yvroud, E.

    1983-01-01

    Ambulatory monitoring of electrocardiograms (ECGs) was facilitated by the introduction of Holter method in the early '60s. Since this time, many researchs have been undertaken in order to improve the overall performances of the recorder and analyser, two unseparated parts of this method. The principal drawbacks of Holter method are well-known: • Recording of ECG is based on the assumption that the arrhythmia of interest will be occurred in monitoring period. • Analysis and arrhythmia detection could be processed only after the monitoring period. This is a time-consuming and tedious job, and subjected to human error. • Process “Recording-Play-back - Analysis - Diagnosis” takes usually many days. In this paper, the design of a microprocessor - based portable recorder will be described. The analysis and classification of arrhythmia are processed immediately upon their occurrence according to a look-up table, which could be programmed to suit a particular need.

  12. Evaluation of repolarization dynamics using the QT-RR regression line slope and intercept relationship during 24-h Holter ECG.

    PubMed

    Fujiki, Akira; Yoshioka, Ryozo; Sakabe, Masao

    2015-03-01

    QT-RR linear regression consists of two parameters, slope and intercept, and the aim of this study was to evaluate repolarization dynamics using the QT-RR linear regression slope and intercept relationship during 24-h Holter ECG. This study included 466 healthy subjects (54.6 ± 14.6 years; 200 men and 266 women) and 17 patients with ventricular arrhythmias, consisted of 10 patients with idiopathic ventricular fibrillation (IVF) and 7 patients with torsades de pointes (TDP). QT and RR intervals were measured from ECG waves based on a 15-s averaged ECG during 24-h Holter recording using an automatic QT analyzing system. The QT interval dependence on the RR interval was analyzed using a linear regression line for each subject ([QT] = A[RR] + B; where A is the slope and B is the y-intercept). The slope of the QT-RR regression line in healthy subjects was significantly greater in women than in men (0.185 ± 0.036 vs. 0.161 ± 0.033, p < 0.001) and the intercept was significantly smaller in women than in men (0.229 ± 0.028 vs. 0.240 ± 0.027, p < 0.001). A scatter diagram of the QT-RR regression line slope and intercept among healthy subjects demonstrated a statistically significant negative correlation (B = -0.62A + 0.34, r = -0.79). Distribution of both scatter diagrams of the slope and the intercept of the QT-RR regression line in patients with IVF and TDP was different from healthy subjects (left corner for IVF and upward shift for TDP). The slope and intercept relationship of the QT-RR linear regression line based on 24-h Holter ECG may become a simple useful marker for abnormality of ventricular repolarization dynamics.

  13. 40 CFR 61.55 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for Mercury § 61.55 Monitoring of emissions and operations. (a) Wastewater treatment plant sludge incineration and drying plants. All the sources for which mercury emissions exceed 1.6 kg (3.5 lb) per 24-hour....54, shall monitor mercury emissions at intervals of at least once per year by use of Method 105...

  14. 40 CFR 61.55 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for Mercury § 61.55 Monitoring of emissions and operations. (a) Wastewater treatment plant sludge incineration and drying plants. All the sources for which mercury emissions exceed 1.6 kg (3.5 lb) per 24-hour....54, shall monitor mercury emissions at intervals of at least once per year by use of Method 105...

  15. 30 CFR 75.336 - Sampling and monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... monitoring requirements. (a) A certified person as defined in § 75.100 shall monitor atmospheres of sealed... sampled at least every 24 hours. (i) Atmospheres with seals of 120 psi or greater shall be sampled until the design strength is reached for every seal used to seal the area. (ii) Atmospheres with seals...

  16. 40 CFR 60.153 - Monitoring of operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... access to the sludge charged so that a well-mixed representative grab sample of the sludge can be... through the combined system shall be continuously monitored. The device used to monitor scrubber pressure... according to method(s) prescribed by the manufacturer at least once each 24-hour operating period....

  17. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... information on a daily basis: (1) The accumulation of sulfur product over each 24-hour period: The monitoring... a level indicator or by manual soundings, with subsequent calculation of the sulfur production rate... emission monitoring system performance evaluation required by § 60.13(c), Performance Specification 2...

  18. 40 CFR 61.55 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for Mercury § 61.55 Monitoring of emissions and operations. (a) Wastewater treatment plant sludge incineration and drying plants. All the sources for which mercury emissions exceed 1.6 kg (3.5 lb) per 24-hour....54, shall monitor mercury emissions at intervals of at least once per year by use of Method 105...

  19. 30 CFR 75.336 - Sampling and monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring requirements. (a) A certified person as defined in § 75.100 shall monitor atmospheres of sealed... sampled at least every 24 hours. (i) Atmospheres with seals of 120 psi or greater shall be sampled until the design strength is reached for every seal used to seal the area. (ii) Atmospheres with seals...

  20. Long-term invariant parameters obtained from 24-h Holter recordings: A comparison between different analysis techniques

    NASA Astrophysics Data System (ADS)

    Cerutti, Sergio; Esposti, Federico; Ferrario, Manuela; Sassi, Roberto; Signorini, Maria Gabriella

    2007-03-01

    Over the last two decades, a large number of different methods had been used to study the fractal-like behavior of the heart rate variability (HRV). In this paper some of the most used techniques were reviewed. In particular, the focus is set on those methods which characterize the long memory behavior of time series (in particular, periodogram, detrended fluctuation analysis, rescale range analysis, scaled window variance, Higuchi dimension, wavelet-transform modulus maxima, and generalized structure functions). The performances of the different techniques were tested on simulated self-similar noises (fBm and fGn) for values of α, the slope of the spectral density for very small frequency, ranging from -1 to 3 with a 0.05 step. The check was performed using the scaling relationships between the various indices. DFA and periodogram showed the smallest mean square error from the expected values in the range of interest for HRV. Building on the results obtained from these tests, the effective ability of the different methods in discriminating different populations of patients from RR series derived from Holter recordings, was assessed. To this extent, the Noltisalis database was used. It consists of a set of 30, 24-h Holter recordings collected from healthy subjects, patients suffering from congestive heart failure, and heart transplanted patients. All the methods, with the exception at most of rescale range analysis, were almost equivalent in distinguish between the three groups of patients. Finally, the scaling relationships, valid for fBm and fGn, when empirically used on HRV series, also approximately held.

  1. Microbial Load Monitor

    NASA Technical Reports Server (NTRS)

    Gibson, S. F.; Royer, E. R.

    1979-01-01

    The Microbial Load Monitor (MLM) is an automated and computerized system for detection and identification of microorganisms. Additionally, the system is designed to enumerate and provide antimicrobic susceptibility profiles for medically significant bacteria. The system is designed to accomplish these tasks in a time of 13 hours or less versus the traditional time of 24 hours for negatives and 72 hours or more for positives usually required for standard microbiological analysis. The MLM concept differs from other methods of microbial detection in that the system is designed to accept raw untreated clinical samples and to selectively identify each group or species that may be present in a polymicrobic sample.

  2. Monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2004-11-23

    The invention provides apparatus and methods which facilitate movement of an instrument relative to an item or location being monitored and/or the item or location relative to the instrument, whilst successfully excluding extraneous ions from the detection location. Thus, ions generated by emissions from the item or location can successfully be monitored during movement. The technique employs sealing to exclude such ions, for instance, through an electro-field which attracts and discharges the ions prior to their entering the detecting location and/or using a magnetic field configured to repel the ions away from the detecting location.

  3. Rethinking the Youth Weight Debate: The 24 Hour Day

    ERIC Educational Resources Information Center

    Dodd, Graham; Biggs, Sarah; Agley, Daniel; Dollman, James; Lushington, Kurt

    2008-01-01

    Approaches to weight management have traditionally focussed on caloric intake versus caloric expenditure. Despite a range of interventions based on these approaches, the proportion of overweight children and adolescents continues to rise. There are increasing indications that other factors, such as sleep duration, may be at play. This commentary…

  4. Collection of a 24-Hour Urine Specimen (Beyond the Basics)

    MedlinePlus

    ... the Licensed Materials from any location via the Internet. b. STANDALONE WORKSTATION: A standalone subscription permits multiple ... computer. A Standalone Workstation license does not include Internet access to the Licensed Materials. c. INSTITUTIONAL SUBSCRIPTION: ...

  5. Sun Blasts 6 CMEs in 24 Hour Period

    NASA Video Gallery

    This movie from the chronograph on board the SOlar and Heliospheric Observatory (SOHO), shows the sun's atmosphere – the corona – from September 17 to September 20. The sun let loose with at ...

  6. Boerhaave's syndrome: Experience with patients presenting later than 24 hours.

    PubMed

    Ganguly, Amit; Porwal, Manish; Khandeparkar, Jagdish

    2015-01-01

    Boerhaave's syndrome is the most sinister cause of esophageal perforation. Clinical presentation is vague. Diagnostic delays are frequent. As condition is rare therefore no consensus exists on management. A wide variety of management options are described in literature, each with its advantages and disadvantages. We present our experience of managing these cases which presented after 24 hr. Of onset of symptoms with emphasis on primary reinforced repair as first line surgical option. PMID:27522739

  7. Attenuated sympathetic nerve responses after 24 hours of bed rest

    NASA Technical Reports Server (NTRS)

    Khan, Mazhar H.; Kunselman, Allen R.; Leuenberger, Urs A.; Davidson, William R Jr; Ray, Chester A.; Gray, Kristen S.; Hogeman, Cynthia S.; Sinoway, Lawrence I.

    2002-01-01

    Bed rest reduces orthostatic tolerance. Despite decades of study, the cause of this phenomenon remains unclear. In this report we examined hemodynamic and sympathetic nerve responses to graded lower body negative pressure (LBNP) before and after 24 h of bed rest. LBNP allows for baroreceptor disengagement in a graded fashion. We measured heart rate (HR), cardiac output (HR x stroke volume obtained by echo Doppler), and muscle sympathetic nerve activity (MSNA) during a progressive and graded LBNP paradigm. Negative pressure was increased by 10 mmHg every 3 min until presyncope or completion of -60 mmHg. After bed rest, LBNP tolerance was reduced in 11 of 13 subjects (P <.023), HR was greater (P <.002), cardiac output was unchanged, and the ability to augment MSNA at high levels of LBNP was reduced (rate of rise for 30- to 60-mmHg LBNP before bed rest 0.073 bursts x min(-1) x mmHg(-1); after bed rest 0.035 bursts x min(-1) x mmHg(-1); P < 0.016). These findings suggest that 24 h of bed rest reduces sympathetic nerve responses to LBNP.

  8. Decreased 24-hour urinary MHPG in childhood autism.

    PubMed

    Young, J G; Cohen, D J; Caparulo, B K; Brown, S L; Maas, J W

    1979-08-01

    The authors compared a group of boys with childhood autism and a group of normal boys of similar age and found a decrease in urinary 3-methoxy-4-hydroxyphenethylene glycol (MHPG) in the autistic group. They hypothesize that autistic children might have an alteration in central and peripheral noradrenergic function, which might be related to impaired regulation of attention, arousal, and anxiety.

  9. A Holter-type, microprocessor-based, rehabilitation instrument for acquisition and storage of plantar pressure data.

    PubMed

    Abu-Faraj, Z O; Harris, G F; Abler, J H; Wertsch, J J

    1997-04-01

    A Holter-type, microprocessor-based, portable, in-shoe, plantar pressure data acquisition system has been developed. The system allows continuous recording of pressure data between the sole of the foot and the shoe during the performance of daily living activities. Fourteen conductive polymer sensors acquire the plantar pressure history, which is then stored in the system memory. Pressures are sampled at a rate of 40 Hz from each of the 14 sensors for up to 8 hrs. The extended recording and processing capacity of the system developed in this study allows quantitative analysis of cumulative plantar pressure and temporal gait data necessary for characterization of event-related alterations in plantar pressures. The alterations that could be examined with the system include rehabilitative, therapeutic, surgical, and nonsurgical treatment. The system is fully portable and does not disrupt the natural gait pattern of the subject during ambulation. Peak plantar pressures, pressure-time integrals, and contact durations are determined for each of the insole sensors.

  10. The impact of fertilization on the chicken egg yolk plasma and granule proteome 24 hours post-lay at room temperature: capitalizing on high-pH/low-pH reverse phase chromatography in conjunction with tandem mass tag (TMT) technology.

    PubMed

    Padliya, Neerav D; Qian, Meiqian; Mimi Roy, Sushmita; Chu, Patrick; Zheng, Haiyan; Tess, Alex; Dariani, Maghsoud; Hariri, Robert J

    2015-07-01

    Chicken egg yolk is a rich source of nutrients providing high quality proteins, vitamins, minerals, carotenoids and antioxidants. Chicken egg yolk, recovered from whole egg within 24 hours post-lay has been utilized as a starting material in the preparation of a dietary supplement that has been demonstrated to lead to gains in muscle mass in a human clinical study. Further, an oil derived from chicken egg yolk has been utilized as a topical agent to treat third degree burn injury. The molecular changes that take place in fertilized, chicken egg yolk during the first 24 hours post-lay are not well understood. By studying how the protein composition of egg yolk varies with fertility status, one can utilize this knowledge to develop egg yolk-based products that have been optimized for specific applications. In this study, a direct quantitative comparison was made between the proteome of fertilized chicken egg yolk and the proteome of unfertilized chicken egg yolk, both maintained at 20 °C and analyzed within 24 hours post-lay. Egg yolk proteins from each fertility state were digested with trypsin, labeled with distinct chemical labels (tandem mass tag reagents) and then combined in a 1 : 1 ratio. A TMT-labeled tryptic digest derived from chicken egg yolk proteins (fertilized and unfertilized) was separated using high-pH/low-pH reverse-phase chromatography and analyzed using mass spectrometry. 225 protein identifications were made from this TMT-labeled tryptic digest based on a minimum of 2 unique peptides observed per protein. 9 proteins increased in abundance in fertilized egg yolk relative to unfertilized egg yolk and 9 proteins decreased in abundance in fertilized egg yolk relative to unfertilized egg yolk. Some proteins that increased in abundance in fertilized egg yolk play an important role in angiogenesis (pleiotrophin, histidine rich glycoprotein) and defense against pathogens (mannose-binding lectin, β-defensin 11, serum amyloid P-component, ovostatin

  11. Explanation of prerequisites for patient monitoring

    NASA Astrophysics Data System (ADS)

    Kessler, Manfred D.; Singer, Michael; Rauh, Robert

    2002-06-01

    Long-term conservation of organs by use of hemoglobin-free perfusion of tissue can be applied during heart surgery as well as transplantation of kidney, liver and pancreas. Furthermore, a conservation of organs during times of 24 hours can be very useful for transport of organs in order to prevent reperfusion injury. Decisive prerequisites for the application of such new tools is the applicability of modern optical tissue sensors for precise monitoring of local tissue function.

  12. Quasi Real Time Data Analysis for Air Quality Monitoring with an Electronic Nose

    NASA Technical Reports Server (NTRS)

    Zhou, Hanying; Shevade, Abhijit V.; Pelletier, Christine C.; Homer, Margie L.; Ryan, M. Amy

    2006-01-01

    Cabin Air Quality Monitoring: A) Functions; 1) Incident monitor for targeted contaminants exceeding targeted concentrations. Identify and quantify. 2) Monitor for presence of compounds associated with fires or overheating electronics. 3) Monitor clean-up process. B) Characteristics; 1) Low mass, low power device. 2) Requires little crew time for maintenance and calibration. 3) Detects, identifies and quantifies selected chemical species at or below 24 hour SMAC.

  13. Intelligent Classification of Heartbeats for Automated Real-Time ECG Monitoring

    PubMed Central

    Park, Juyoung

    2014-01-01

    Abstract Background: The automatic interpretation of electrocardiography (ECG) data can provide continuous analysis of heart activity, allowing the effective use of wireless devices such as the Holter monitor. Materials and Methods: We propose an intelligent heartbeat monitoring system to detect the possibility of arrhythmia in real time. We detected heartbeats and extracted features such as the QRS complex and P wave from ECG signals using the Pan–Tompkins algorithm, and the heartbeats were then classified into 16 types using a decision tree. Results: We tested the sensitivity, specificity, and accuracy of our system against data from the MIT-BIH Arrhythmia Database. Our system achieved an average accuracy of 97% in heartbeat detection and an average heartbeat classification accuracy of above 96%, which is comparable with the best competing schemes. Conclusions: This work provides a guide to the systematic design of an intelligent classification system for decision support in Holter ECG monitoring. PMID:25010717

  14. 40 CFR 63.11527 - What are the monitoring requirements for new and existing sources?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... any VE, you must conduct a Method 22 (appendix A-7 of 40 CFR part 60) test following the requirements... visual monitoring reveals the presence of any VE, you must conduct a Method 22 (appendix A-7 of 40 CFR...-7 of 40 CFR part 60) test following the requirements of § 63.11528(b)(1) within 24 hours...

  15. 40 CFR 63.11527 - What are the monitoring requirements for new and existing sources?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... any VE, you must conduct a Method 22 (appendix A-7 of 40 CFR part 60) test following the requirements... visual monitoring reveals the presence of any VE, you must conduct a Method 22 (appendix A-7 of 40 CFR...-7 of 40 CFR part 60) test following the requirements of § 63.11528(b)(1) within 24 hours...

  16. ECG patch monitors for assessment of cardiac rhythm abnormalities.

    PubMed

    Lobodzinski, S Suave

    2013-01-01

    The primary goal of long-term monitoring is the improvement of diagnostic yield. Despite the clear utility of Holter monitoring in clinical cardiology, issues of relatively low diagnostic yield, cost and inconvenience have motivated the development of ultra-portable devices referred to as ECG patch monitors. Although the "gold standard" for assessing cardiac rhythm abnormalities remains a 12-lead Holter, there is an increasing interest in portable monitoring devices that provide the opportunity for evaluating cardiac rhythm in real-world environments such as the workplace or home. To facilitate patient acceptance these monitors underwent a radical miniaturization and redesign to include wireless communication, water proofing and a patch carrier for attaching devices directly to the skin. We review recent developments in the field of "patch" devices primarily designed for very long-term monitoring of cardiac arrhythmic events. As the body of supporting clinical validation data grows, these devices hold promise for a variety of cardiac monitoring applications. From a clinical and research standpoint, the capacity to obtain longitudinal cardiac activity data by patch devices may have significant implications for device selection, monitoring duration, and care pathways for arrhythmia evaluation and atrial fibrillation surveillance. From a research standpoint, the new devices may allow for the development of novel diagnostic algorithms with the goal of finding patterns and correlations with exercise and drug regimens.

  17. Clinical Practice Guideline for the Treatment of Intrinsic Circadian Rhythm Sleep-Wake Disorders: Advanced Sleep-Wake Phase Disorder (ASWPD), Delayed Sleep-Wake Phase Disorder (DSWPD), Non-24-Hour Sleep-Wake Rhythm Disorder (N24SWD), and Irregular Sleep-Wake Rhythm Disorder (ISWRD). An Update for 2015

    PubMed Central

    Auger, R. Robert; Burgess, Helen J.; Emens, Jonathan S.; Deriy, Ludmila V.; Thomas, Sherene M.; Sharkey, Katherine M.

    2015-01-01

    A systematic literature review and meta-analyses (where appropriate) were performed and the GRADE approach was used to update the previous American Academy of Sleep Medicine Practice Parameters on the treatment of intrinsic circadian rhythm sleep-wake disorders. Available data allowed for positive endorsement (at a second-tier degree of confidence) of strategically timed melatonin (for the treatment of DSWPD, blind adults with N24SWD, and children/ adolescents with ISWRD and comorbid neurological disorders), and light therapy with or without accompanying behavioral interventions (adults with ASWPD, children/adolescents with DSWPD, and elderly with dementia). Recommendations against the use of melatonin and discrete sleep-promoting medications are provided for demented elderly patients, at a second- and first-tier degree of confidence, respectively. No recommendations were provided for remaining treatments/ populations, due to either insufficient or absent data. Areas where further research is needed are discussed. Citation: Auger RR, Burgess HJ, Emens JS, Deriy LV, Thomas SM, Sharkey KM. Clinical practice guideline for the treatment of intrinsic circadian rhythm sleep-wake disorders: advanced sleep-wake phase disorder (ASWPD), delayed sleep-wake phase disorder (DSWPD), non-24-hour sleep-wake rhythm disorder (N24SWD), and irregular sleep-wake rhythm disorder (ISWRD). An update for 2015. J Clin Sleep Med 2015;11(10):1199–1236. PMID:26414986

  18. Enhanced Raman Monitor Project

    NASA Technical Reports Server (NTRS)

    Westenskow, Dwayne

    1996-01-01

    Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

  19. A unique digital electrocardiographic repository for the development of quantitative electrocardiography and cardiac safety: the Telemetric and Holter ECG Warehouse (THEW).

    PubMed

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following 3 components: data, expertise, and tools. The data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous electrocardiogram signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the American Heart Association - Beth Israel Hospital (AHA-BIH) arrhythmia database, and the Common Standard for Electrocardiography (CSE) database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available.

  20. A unique digital electrocardiographic repository for the development of quantitative electrocardiography and cardiac safety: the Telemetric and Holter ECG Warehouse (THEW).

    PubMed

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following 3 components: data, expertise, and tools. The data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous electrocardiogram signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the American Heart Association - Beth Israel Hospital (AHA-BIH) arrhythmia database, and the Common Standard for Electrocardiography (CSE) database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available. PMID:20863512

  1. Small Active Radiation Monitor

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.

    2004-01-01

    A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the

  2. WIPP Transparency Project - container tracking and monitoring demonstration using the Authenticated Tracking and Monitoring System (ATMS)

    SciTech Connect

    SCHOENEMAN, J. LEE; SMARTT, HEIDI ANNE; HOFER, DENNIS

    2000-01-27

    The Authenticated Tracking and Monitoring System (ATMS) is designed to answer the need for global monitoring of the status and location of proliferation-sensitive items on a worldwide basis, 24 hours a day. ATMS uses wireless sensor packs to monitor the status of the items within the shipment and surrounding environmental conditions. Receiver and processing units collect a variety of sensor event data that is integrated with GPS tracking data. The collected data are transmitted to the International Maritime Satellite (INMARSAT) communication system, which then sends the data to mobile ground stations. Authentication and encryption algorithms secure the data during communication activities. A typical ATMS application would be to track and monitor the stiety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements.

  3. The Relationship between Serum Lipid Fractions and Heart Rate Variability in Diabetic Patients with Statin Therapy

    PubMed Central

    BADEA, ANAMARIA RALUCA; NEDELCU, LAURENTIU; VALEANU, MADALINA; ZDRENGHEA, DUMITRU

    2014-01-01

    Background and aims The aim of this study is to identify and highlight the relationship between serum lipid fractions and heart rate variability in diabetic patients receiving statin therapy. Patients and methods The study was performed in a group of 87 type 2 diabetic patients on statin associated therapy. All patients were on Holter ECG 24 hours monitored with three channel monitor (Labtech ECG Holter monitor), and data were analyzed on a commercially available software (Cardiospy PC SW/EV 5.02.06.02). Concentrations of biochemical parameters were determined using specific enzymatic assays on an autoanalyzer Olympus AU 680. In the studied patients, we analyzed Holter/24 hours monitoring reports with respect to heart rate variability indexes, arrhythmic events and myocardial ischemia. Results It was noticed that the mean values of serum TG were slightly elevated, TC levels were close to the limits specified by the guidelines for diabetic patients and for patients with cardiovascular diseases, with no significant differences between males and females. After analyzing the HRV in both time and frequency domains, we found no strong correlations between any of the HRV indexes and any of the lipid fractions. Conclusions The results suggest that statin therapy may reduce the autonomic impairment secondary to dyslipidemia. PMID:26528015

  4. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  5. Optimal Duration of Monitoring for Atrial Fibrillation in Cryptogenic Stroke: A Nonsystematic Review

    PubMed Central

    Hariri, Essa; Hachem, Ahmad; Sarkis, Georges; Nasr, Samer

    2016-01-01

    Atrial fibrillation (AF) is the most common form of cardiac arrhythmias and an independent risk factor for stroke. Despite major advances in monitoring strategies, clinicians tend to miss the diagnoses of AF and especially paroxysmal AF due mainly to its asymptomatic presentation and the rather limited duration dedicated for monitoring for AF after a stroke, which is 24 hours as per the current recommended guidelines. Hence, determining the optimal duration of monitoring for paroxysmal atrial fibrillation after acute ischemic stroke remains a matter of debate. Multiple trials were published in regard to this matter using both invasive and noninvasive monitoring strategies for different monitoring periods. The data provided by these trials showcase strong evidence suggesting a longer monitoring strategy beyond 24 hours is associated with higher detection rates of AF, with the higher percentage of patients detected consequently receiving proper secondary stroke prevention with anticoagulation and thus justifying the cost-effectiveness of such measures. Overall, we thus conclude that increasing the monitoring duration for AF after a cryptogenic stroke to at least 72 hours will indeed enhance the detection rates, but the cost-effectiveness of this monitoring strategy compared to longer monitoring durations is yet to be established. PMID:27314027

  6. 24-hour central aortic systolic pressure and 24-hour central pulse pressure are related to diabetic complications in type 1 diabetes – a cross-sectional study

    PubMed Central

    2013-01-01

    Background Non-invasive measurements of 24 hour ambulatory central aortic systolic pressure (24 h-CASP) and central pulse pressure (24 h-CPP) are now feasible. We evaluate the relationship between 24 h central blood pressure and diabetes-related complications in patients with type 1 diabetes. Methods The study was cross-sectional, including 715 subjects: 86 controls (C), 69 patients with short diabetes duration (< 10 years), normoalbuminuria (< 30 mg/24 h) without receiving antihypertensive treatment (SN), 211 with longstanding diabetes (≥ 10 years) and normoalbuminuria (LN), 163 with microalbuminuria (30-299 mg/24 h) (Mi) and 186 with macroalbuminuria (> 300 mg/24 h) (Ma). 24 h-CASP and 24 h-CPP was measured using a tonometric wrist-watch-like device (BPro, HealthStats, Singapore) and derived using N-point moving average. Results In C, SN, LN, Mi and Ma mean ± SD 24 h-CASP was: 114 ± 17, 115 ± 13, 121 ± 13, 119 ± 16 and 121 ± 13 mmHg (p < 0.001); and 24 h-CPP: 38 ± 8, 38 ± 7, 44 ± 10, 46 ± 11 and 46 ± 11 mmHg, (p < 0.001). Following rigorous adjustment (24 h mean arterial pressure and conventional risk factors), 24 h-CASP and 24 h-CPP increased with diabetes, albuminuria degree, previous cardiovascular disease (CVD), retinopathy and autonomic dysfunction (p ≤ 0.031). Odds ratios per 1 standard deviation increase in 24 h-CASP, 24 h-CPP and 24 h systolic blood pressure (24 h-SBP) were for CVD: 3.19 (1.68-6.05), 1.43 (1.01-2.02) and 2.39 (1.32-4.33), retinopathy: 4.41 (2.03-9.57), 1.77 (1.17-2.68) and 3.72 (1.85-7.47) and autonomic dysfunction: 3.25 (1.65-6.41), 1.64 (1.12-2.39) and 2.89 (1.54-5.42). Conclusions 24 h-CASP and 24 h-CPP was higher in patients vs. controls and increased with diabetic complications independently of covariates. Furthermore, 24 h-CASP was stronger associated to complications than 24 h-SBP. The prognostic significance of 24 h-CASP and 24 h-CPP needs to be determined in follow-up studies. Trial registration ClinicalTrials.gov ID NCT01171248. PMID:23978271

  7. Possible theoretical explanations for occasional days of non-field-aligned diffusion at neutron monitor energies

    NASA Technical Reports Server (NTRS)

    Forman, M. A.

    1975-01-01

    It has been shown previously (Anath et al., 1973 and Kane, 1974) that 20 to 25% of days, the diffusion component of the cosmic-ray neutron diurnal anisotropy is directed more than 30 degrees away from the ecliptic projection of the interplanetary magnetic field averaged over the same 24 hours. A number of explanations for this deviation are discussed and it is concluded that transverse gradient drifts due to gradients perpendicular to the ecliptic are likely, that diurnal variations in the diffusion component of the neutron anisotropy may affect results from single stations and that the 24 hour mean interplanetary magnetic field may not be the field appropriate to the streaming equation at neutron monitor energies.

  8. Applications of medical intelligence in remote monitoring.

    PubMed

    Vassányi, István; Kozmann, György; Bánhalmi, András; Végsö, Balázs; Kósa, István; Dulai, Tibor; Tarjányi, Zsolt; Tuboly, Gergely; Cserti, Péter; Pintér, Balázs

    2011-01-01

    Prevention and rehabilitation efficiency can greatly benefit from the application of intelligent, 24 hour tele-diagnostics and tele-care information systems. Tele-monitoring also supports a new level of medical supervision over the patient's lifestyle. In this paper we briefly present the architecture and development phase results of the Alpha remote monitoring system. The novelty of the system is the unified and flexible processing of various signals retrieved from modern, unobtrusive devices in an efficient signal abstraction framework. The signals include PIR motion sensors that record patient movement in the home, physiological signals and also patient responses in various tests performed on the GUI of the central home unit. We have developed and tested the prototype system with promising results.

  9. Monitoring and detection platform to prevent anomalous situations in home care.

    PubMed

    Villarrubia, Gabriel; Bajo, Javier; De Paz, Juan F; Corchado, Juan M

    2014-01-01

    Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost. PMID:24905853

  10. Monitoring and Detection Platform to Prevent Anomalous Situations in Home Care

    PubMed Central

    Villarrubia, Gabriel; Bajo, Javier; De Paz, Juan F.; Corchado, Juan M.

    2014-01-01

    Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost. PMID:24905853

  11. Monitoring and detection platform to prevent anomalous situations in home care.

    PubMed

    Villarrubia, Gabriel; Bajo, Javier; De Paz, Juan F; Corchado, Juan M

    2014-06-05

    Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost.

  12. Electrocardiographic patch devices and contemporary wireless cardiac monitoring

    PubMed Central

    Fung, Erik; Järvelin, Marjo-Riitta; Doshi, Rahul N.; Shinbane, Jerold S.; Carlson, Steven K.; Grazette, Luanda P.; Chang, Philip M.; Sangha, Rajbir S.; Huikuri, Heikki V.; Peters, Nicholas S.

    2015-01-01

    Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG), Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable “on-body” ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks) is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery. PMID:26074823

  13. Ventricular Ectopy: Impact of Self-reported Stress following Myocardial Infarction

    PubMed Central

    Smith, Patrick J.; Blumenthal, James A.; Babyak, Michael A.; Georgiades, Anastasia; Sherwood, Andrew; Sketch, Michael H.; Watkins, Lana L.

    2007-01-01

    Background Although psychological stress has been implicated in the pathogenesis of ventricular arrhythmias, the relationship between self-reported stress and ventricular ectopy has not been evaluated under naturalistic conditions in acute post-MI patients, a group at elevated risk for arrhythmias. Methods Diary-reported stress was measured during 24-hour Holter monitoring in 80 patients (52 men, 28 women) approximately 12 weeks following MI. In addition, state and trait anxiety were measured using the Spielberger State and Trait anxiety inventory (STAI), administered at the beginning of the 24-hour holter monitoring session. The relationship between diary reported stress, anxiety, and ventricular ectopy was evaluated. Results Mean diary-reported stress (β= .29, p = .01) was associated with total ventricular ectopy. State anxiety was also associated with 24-hour ectopy (β= .24, p = .04); however, trait anxiety was not significantly associated with ectopy. Temporal analyses of the relationship between stress and ectopy showed that diary-reported stress was associated with an increase in the number of VPBs occurring in the following hour (B = 0.74, p < .0001). Conclusions These findings extend existing evidence linking psychological factors to ventricular arrhythmias by demonstrating that psychological stress predicts increased arrhythmic activity during routine daily activities in post-MI patients. PMID:17174651

  14. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    PubMed Central

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  15. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows.

    PubMed

    Nobre, Fernando; Mion Junior, Décio

    2016-06-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  16. Continuous pulse amplitude monitoring of infrainguinal bypass grafts in the first 24 postoperative hours.

    PubMed

    Blankensteijn, J D; Abbott, W M

    1996-07-01

    To evaluate continuous pulse amplitude monitoring (CPAM) as a method for early postoperative graft surveillance following infrainguinal bypass surgery, a prospective observational study was carried out in 34 consecutive infrainguinal bypass grafts. CPAM tracings were compared with pre- and postoperative pulse palpation, ankle/brachial index (ABI) measurements, and pulse volume recordings (PVR). The utility of each method was defined by its ability to demonstrate graft patency in the first 24 hours. Pulse palpation was considered a useful monitoring tool if a postoperative pedal pulse was found in the absence of palpable preoperative pulses. The ABI qualified in this respect if a postoperative increase of at least 0.25 could be demonstrated; for PVR tracings an increase of at least one category was required. The utility of CPAM was established by an increase of at least 5 mm compared to the preoperative values. There were no early graft failures. We were therefore unable to calculate the ability of the studies to predict graft failure. The percentages (95% confidence limits) for which pulse palpation, ABI, and PVR were found capable of demonstrating graft patency were 50% (range 34% to 66%), 53% (range 36% to 70%), and 71% (range 54% to 83%), respectively. CPAM appeared to be far superior to these three methods with a utility of 94% (range 81% to 98%; p < 0.05). Patient and operator acceptability of CPAM was high. Skin pressure problems are a potential risk if the CPAM probe is left attached to the skin for more than 24 hours. CPAM was a valuable and reliable means of monitoring infrainguinal vascular reconstructions. Apart from being inexpensive, continuous, objective, and simple, CPAM is noninvasive and painless. It is advisable to remove the probe 24 hours after surgery, when the most crucial period for graft monitoring has passed. PMID:8879395

  17. Influence of time of 24-hour day on depth of processing in recall memory.

    PubMed

    Maury, P; Queinnec, Y

    1992-05-01

    In this paper we report hourly variations in recall of words in a short-term memory task. Tests were carried out at 18.00, 22.00, 02.00 and 06.00 hours. The words to be memorized were preceded by a question designed to shape the type of encoding adopted by the subjects. The question concerned semantic, typographic or structural characteristics of the word. After presentation of all the words, the subjects were tested in free recall. Time of day had no effect on overall recall scores. Nevertheless, we observed a phase difference in the recall of items processed at superficial or deep levels. Items encoded by typographical attributes were more readily recalled at 02.00 than at 18.00, whereas semantically encoded words were less well recalled at night than during the day. There was also an interaction between the serial position of the items and time of day. At 22.00 and 02.00, subjects recalled words from the end of the list better. The results are discussed in terms of resource allocation models.

  18. Microstructure of the rat's intake of food, sucrose and saccharin in 24-hour tests.

    PubMed

    Smith, J C

    2000-03-01

    A detailed description of a method for collecting meal and drinking bout patterns for the rat over 24-h preference tests is presented. Both the hardware and software are described for data collection with a 6-s resolution. As an example of the value of knowing the details of ingestive patterns, data are presented describing the meal and drinking bout patterns during daylong preference tests between sucrose or saccharin vs. water. During these two-day tests at each of a wide range of concentrations, the intake of powdered Purina Chow, sucrose and saccharin were observed and quantified into meals or bouts. The analysis allowed for a comparison of sucrose and saccharin ingestion in terms of number of bouts, duration of bouts, rate of licking during bouts, the juxtaposition of eating and drinking and the day/night patterns of intake. Comparisons of drinking during bouts were made with electrophysiological and short-term taste test data. The usefulness of microstructure analysis is discussed.

  19. [Rectal temperature trends during 24 hours in a hot climate with and without nutritional support].

    PubMed

    Cisse, F; Seck-Gassama, S; Gueye, L; Seck, D; Samb, A; Ndoye, R; Martineaud, J P

    1997-01-01

    A group of 22 young subjects staying in rest was studied in the aim to follow the nycthemeral evolution of the rectal temperature, according to two situations: 1) normal feeding, 2) absence of feeding. The use of drinking water was not limited. The experimentation was carried out in tropical area, Kédougou (Eastern Senegal), during a high period of temperature. The mean of day temperature was 38 degrees C and the night temperature, 22 degrees C. The skin and rectal temperature, the arterial pressure and the cardiac frequency were measured every three hours. The results showed a significant difference in the nycthemeral rythm of the rectal temperatures. The nocturnal temperatures were not different in the two conditions. We observed a significant elevation (delta = 0.31 +/- 0.18 degree C) of the diurne post prandial temperature. The results supported that the thermic modification observed during the experience were linked to the feed.

  20. 24 Hours in a Day: A Listening Update to the Time Studies

    ERIC Educational Resources Information Center

    Janusik, Laura A.; Wolvin, Andrew D.

    2009-01-01

    Time is an important communication variable that has been impacted by new technology and changed the way people communicate. This study of communication time use by college students provides an update to earlier studies by factoring in computer and telephone use--media that have forced a multitasking approach to communication. Undergraduate…

  1. The 24-hour respiratory quotient predicts energy intake and changes in body mass.

    PubMed

    Longo, Kenneth A; Charoenthongtrakul, Soratree; Giuliana, Derek J; Govek, Elizabeth K; McDonagh, Thomas; Distefano, Peter S; Geddes, Brad J

    2010-03-01

    To define the relationship between the respiratory quotient (RQ) and energy intake (EI) and to determine the impact of spontaneous locomotor activity (LMA) in the development of diet-induced obesity (DIO), we fed C57BL/6 mice a high-fat diet (HFD) for either 4 days or 17 wk and analyzed them using indirect calorimetry. Importantly, changes in body mass during calorimetry (DeltaM(b)) significantly covaried with RQ and EI; adjusting the data for DeltaM(b) permitted an analysis of the energy-balanced state. The 24-h RQ strongly predicted 24-h EI, and the slope of this relationship was diet dependent (HFD or chow) but independent of the HFD feeding period. Early-stage DIO was characterized by dark-period hyperphagia and fat storage, offset by greater light-period lipid oxidation; later stage DIO mice had a milder hyperphagia and lower substrate flexibility. Consequently, whereas 24-h RQ equaled the food quotient of the HFD in both early- and late-stage DIO, the range of RQ values was negatively correlated with, and mostly explained by, 24-h EI only in late-stage DIO. Lean and early-stage DIO mice had similar LMA values that were reduced in late-stage DIO. However, LMA significantly explained variance in total energy expenditure (EE) in only early-stage DIO mice. This indicated that the link between LMA and EE was a transient adaptive response to early DIO, whereas the later loss of LMA did not explain body weight gain in C57BL/6 DIO mice.

  2. Sex difference in the near-24-hour intrinsic period of the human circadian timing system

    PubMed Central

    Duffy, Jeanne F.; Cain, Sean W.; Chang, Anne-Marie; Phillips, Andrew J. K.; Münch, Mirjam Y.; Gronfier, Claude; Wyatt, James K.; Dijk, Derk-Jan; Czeisler, Charles A.

    2011-01-01

    The circadian rhythms of melatonin and body temperature are set to an earlier hour in women than in men, even when the women and men maintain nearly identical and consistent bedtimes and wake times. Moreover, women tend to wake up earlier than men and exhibit a greater preference for morning activities than men. Although the neurobiological mechanism underlying this sex difference in circadian alignment is unknown, multiple studies in nonhuman animals have demonstrated a sex difference in circadian period that could account for such a difference in circadian alignment between women and men. Whether a sex difference in intrinsic circadian period in humans underlies the difference in circadian alignment between men and women is unknown. We analyzed precise estimates of intrinsic circadian period collected from 157 individuals (52 women, 105 men; aged 18–74 y) studied in a month-long inpatient protocol designed to minimize confounding influences on circadian period estimation. Overall, the average intrinsic period of the melatonin and temperature rhythms in this population was very close to 24 h [24.15 ± 0.2 h (24 h 9 min ± 12 min)]. We further found that the intrinsic circadian period was significantly shorter in women [24.09 ± 0.2 h (24 h 5 min ± 12 min)] than in men [24.19 ± 0.2 h (24 h 11 min ± 12 min); P < 0.01] and that a significantly greater proportion of women have intrinsic circadian periods shorter than 24.0 h (35% vs. 14%; P < 0.01). The shorter average intrinsic circadian period observed in women may have implications for understanding sex differences in habitual sleep duration and insomnia prevalence. PMID:21536890

  3. Case Study: Psychiatric Misdiagnosis of Non-24-Hours Sleep-Wake Schedule Disorder Resolved by Melatonin

    ERIC Educational Resources Information Center

    Dagan, Yaron; Ayalon, Liat

    2005-01-01

    This case study describes a 14-year-old male suffering from significant academic and personal difficulties, who has been diagnosed with depression, schizotypal personality disorder, and learning disabilities. Because of excessive sleepiness, assessment for a potential sleep disorder was performed. An overnight polysomnographic study revealed no…

  4. Radio telemetry documents 24-hour feeding activity of wintering lesser scaup

    USGS Publications Warehouse

    Custer, Christine M.; Custer, T.W.; Sparks, D.W.

    1996-01-01

    We used radio telemetry to record 198 h of feeding behavior of five Lesser Scaup (Aythya affinis) on the Indiana Harbor Canal in northwestern Indiana during January and February 1994. Lesser Scaup fed for short periods of time intermittently during each 24-h period. Lesser Scaup fed a total of 96 min during the day and 226 min during the night. They fed more between sunset and midnight (31.9% of the period, P = 0.003) than between sunrise and noon (11.6%) or noon and sunset (19.5%); time spent feeding between midnight and sunrise (26.3%) did not differ from other times of day. Mean dive duration (22.9 ± 0.64 sec) did not vary by time of day (P = 0.186-0.744). These results are the first 24-h feeding activity reported for individually marked Lesser Scaup.

  5. Australian Nuclear Science & Technology Organization (ANSTO) Interdicted Samples 24-Hour Report

    SciTech Connect

    Kristo, M J; Hutcheon, I D; Grant, P M; Borg, L E; Sharp, M A; Moody, K J; Conrado, C L; Wooddy, P T

    2011-01-27

    Categorization is complete. Samples 11-3-1 (NSR-F-270409-01) and 11-3-2 (NSR-F-270409-02) are depleted uranium powders of moderate purity ({approx}65-80 % U). The uranium feed stocks for 11-3-1 and 11-3-2 have both experienced a neutron flux (as demonstrated by the presence of {sup 232}U). Sample 11-3-3 is indistinguishable from a natural uranium ore concentrate of moderate purity ({approx}70-80% U). Two anomalous objects (11-3-1-4 and 11-3-2-5) were found in the material during aliquoting. These objects might be valuable for route attribution.

  6. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... can usually enjoy an uninterrupted night's sleep. If sleeping period is of more than 8 hours, only 8.... Pa. 1947).) (b) Interruptions of sleep. If the sleeping period is interrupted by a call to duty, the... cannot get a reasonable night's sleep, the entire period must be counted. For enforcement purposes,...

  7. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... can usually enjoy an uninterrupted night's sleep. If sleeping period is of more than 8 hours, only 8.... Pa. 1947).) (b) Interruptions of sleep. If the sleeping period is interrupted by a call to duty, the... cannot get a reasonable night's sleep, the entire period must be counted. For enforcement purposes,...

  8. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... can usually enjoy an uninterrupted night's sleep. If sleeping period is of more than 8 hours, only 8.... Pa. 1947).) (b) Interruptions of sleep. If the sleeping period is interrupted by a call to duty, the... cannot get a reasonable night's sleep, the entire period must be counted. For enforcement purposes,...

  9. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... can usually enjoy an uninterrupted night's sleep. If sleeping period is of more than 8 hours, only 8.... Pa. 1947).) (b) Interruptions of sleep. If the sleeping period is interrupted by a call to duty, the... cannot get a reasonable night's sleep, the entire period must be counted. For enforcement purposes,...

  10. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... can usually enjoy an uninterrupted night's sleep. If sleeping period is of more than 8 hours, only 8.... Pa. 1947).) (b) Interruptions of sleep. If the sleeping period is interrupted by a call to duty, the... cannot get a reasonable night's sleep, the entire period must be counted. For enforcement purposes,...

  11. Cross-validation of a composite pain scale for preschool children within 24 hours of surgery.

    PubMed

    Suraseranivongse, S; Santawat, U; Kraiprasit, K; Petcharatana, S; Prakkamodom, S; Muntraporn, N

    2001-09-01

    This study was designed to cross-validate a composite measure of the pain scales CHEOPS (Children's Hospital of Eastern Ontario Pain Scale), OPS (Objective Pain Scale, simplified for parent use by replacing blood pressure measurement with observation of body language or posture), TPPPS (Toddler Preschool Postoperative Pain Scale) and FLACC (Face, Legs, Activity, Cry, Consolability) in 167 Thai children aged 1-5.5 yr. The pain scales were translated and tested for content, construct and concurrent validity, including inter-rater and intra-rater reliabilities. Discriminative validity in immediate and persistent pain for the age groups < or =3 and >3 yr were also studied. The children's behaviour was videotaped before and after surgery, before analgesia had been given in the post-anaesthesia care unit (PACU), and on the ward. Four observers then rated pain behaviour from rearranged videotapes. The decision to treat pain was based on routine practice and was made by a researcher unaware of the rating procedure. All tools had acceptable content validity and excellent inter-rater and intra-rater reliabilities (intraclass correlation >0.9 and >0.8 respectively). Construct validity was determined by the ability to differentiate the group with no pain before surgery and a high pain level after surgery, before analgesia (P<0.001). The positive correlations among all scales in the PACU and on the ward (r=0.621-0.827, P<0.0001) supported concurrent validity. Use of the kappa statistic indicated that CHEOPS yielded the best agreement with the routine decision to treat pain. The younger and older age groups both yielded very good agreement in the PACU but only moderate agreement on the ward. On the basis of data from this study, we recommend CHEOPS as a valid, reliable and practical tool. PMID:11517123

  12. Albumin infusion in humans does not model exercise induced hypervolaemia after 24 hours

    NASA Technical Reports Server (NTRS)

    Haskell, A.; Gillen, C. M.; Mack, G. W.; Nadel, E. R.

    1998-01-01

    We rapidly infused 234 +/- 3 mL of 5% human serum albumin in eight men while measuring haematocrit, haemoglobin concentration, plasma volume (PV), albumin concentration, total protein concentration, osmolality, sodium concentration, renin activity, aldosterone concentration, and atrial natriuretic peptide concentration to test the hypotheses that plasma volume expansion and plasma albumin content expansion will not persist for 24 h. Plasma volume and albumin content were expanded for the first 6 h after infusion (44.3 +/- 1.9-47.2 +/- 2.0 mL kg-1 and 1.9 +/- 0.1-2.1 +/- 0.1 g kg-1 at pre-infusion and 1 h, respectively, P < 0.05), but by 24 h plasma volume and albumin content decreased significantly from 1 h post-infusion and were not different from pre-infusion (44.8 +/- 1.9 mL kg-1 and 1.9 +/- 0.1 g kg-1, respectively). Plasma aldosterone concentration showed a significant effect of time over the 24 h after infusion (P < 0.05), and showed a trend to decrease at 2 h after infusion (167.6 +/- 32.5(-1) 06.2 +/- 13.4 pg mL-1, P = 0.07). These data demonstrate that a 6.8% expansion of plasma volume and 10.5% expansion of plasma albumin content by infusion does not remain in the vascular space for 24 h and suggest a redistribution occurs between the intravascular space and interstitial fluid space.

  13. 24 hour forecast of the surface UV for the antipsoriatic heliotherapy in Poland.

    PubMed

    Krzyścin, J W; Guzikowski, J; Czerwińska, A; Lesiak, A; Narbutt, J; Jarosławski, J; Sobolewski, P S; Rajewska-Więch, B; Wink, J

    2015-07-01

    Analyses of the spectral and broad-band UV data collected at Belsk (20.79°E, 51.84°N), Poland, show that standard broad-band instrument, Solar Light (SL) 501A, could be used for measurements of both erythemal and antipsoriatic irradiance. A prognostic model is proposed for the next-day duration of outdoor exposure required to receive a dose, the so-called minimum antipsoriatic dose (MAD), equivalent to that received by standard antipsoriatic daily treatment in the phototherapy cabinet containing TL-01 fluorescent tubes. The model uses the 24 h forecast of the column amount of ozone (to predict next day clear sky UV irradiance), and low- and mid-level cloudiness (to estimate a reduction of the clear-sky UV irradiation due to clouds). The predicted duration of sunbathing required to receive a dose of 1 MAD matches the observed value, i.e. the correlation coefficients is 0.68. If the model predicts the antipsoriatic exposure over 1 MAD threshold the observed dose will be also above this threshold in 91% of cases. Thus, the model could be used for planning the next-day outdoor exposure to clear psoriasis. Hourly resolved maps, starting from 6 am up to 1 pm (GMT), showing the duration of antipsoriatic exposure over Poland are made public. The model provides a tool for a psoriatic patient to find the sunbathing starting time and its duration, which has the same healing potential as a single indoor phototherapy session.

  14. Relationships between renin, aldosterone, and 24-hour ambulatory blood pressure in obese adolescents.

    PubMed

    Shatat, Ibrahim F; Flynn, Joseph T

    2011-04-01

    Renin-angiotensin system (RAS) activation and abnormalities of ambulatory blood pressure (ABP) are present in obesity, but relationships between components of the RAS and ABP have not been defined in the young. Anthropometric measurements and 24-h ABP were obtained on 30 obese adolescents with and without type 2 diabetes mellitus. Plasma renin activity (PRA), aldosterone, and other cardiovascular risk factors were measured. Median PRA levels were 2.5 [interquartile range (IQR), 1.7-4.1] ng/mL/h and were higher in the diabetic subjects compared with the nondiabetics. Females had significantly higher PRA than males 3.2 (IQR, 2-4.8) versus 1.8 (IQR, 1.1-2.9) ng/mL/h (p = 0.04) and were more obese. BMI Z score and PRA were significantly correlated (rho = 0.46, p < 0.001). PRA inversely correlated with 24-h systolic ABP (rho = -0.46, p = 0.02) and strongly with 24-h pulse pressure (rho = -0.61, p = 0.001). Aldosterone levels were also correlated with 24-h pulse pressure (rho = -0.46, p = 0.02). In multivariate models, lower PRA was independently associated with 24-h systolic blood pressure. In this study, PRA was positively correlated with BMI, but the relationships between components of the RAS and ABP were inverse. Further studies are needed to define the pathophysiologic relationship between RAS components and blood pressure regulation in obese youth.

  15. Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Weldhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    1998-01-01

    Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

  16. 24-hour pattern of work-related injury risk of French firemen: nocturnal peak time.

    PubMed

    Riedel, Marc; Berrez, Stéphane; Pelisse, Didier; Brousse, Eric; Forget, Coralie; Marlot, Michel; Smolensky, Michael H; Touitou, Yvan; Reinberg, Alain

    2011-10-01

    The first aim of the study was to assess clock-time patterning of work-related injuries (WRIs) of firemen (FM) of Saône et Loire-71 (France) during the 4-yr span of 1 January 2004 to 31 December 2007. FM of this service are legally required to log every WRI and seek its evaluation by the medical service, whether the WRI was the result of worksite duties or exercise/sport activities at the station. WRI was defined specifically as a (nonexercise, nonsport, and nonemotional/stress) work-associated trauma, verified both by log book and medical records. For the corresponding years, the 24-h pattern of emergency calls (Calls) plus road traffic (Traffic) on the main roads of the service area was also assessed. Relative risk (R) of WRI was calculated as the quantity of WRIs/h divided by the quantity of Call responses/h × 1000, which takes into account the number of at-risk FM/unit time, since each dispatched emergency vehicle is staffed with 4 FM. Comparably trained regular (RFM) and volunteer (VFM) FM experienced a total of 187 WRIs. The 24-h WRI curve patterns of RFM and VFM were correlated (r = 0.4, p < .05), with no histogram difference (p > .05). Analysis of variance (ANOVA) validated comparable clock-time patterns in WRIs of RFM and VFM each year and each season (all p < .0001). Thus, time series of the RFM and VFM were pooled, revealing a statistical significant 24-h variation in WRIs (ANOVA, p > .0006; Cosinor analysis, p < .0001), with peak at 16:00 h and trough at 04:00 h. The 24-h pattern in Traffic, which mirrors that of human activity, with peak ∼18:00 h and trough ∼03:00 h, was also verified (ANOVA, p < .0001; Cosinor, p < .0001). Calls (n = 112,059) resulting in FM responses also exhibited statistically significant 24-h variation, with peak at ∼20:00 h and trough at ∼06:00 h. The 24-h pattern of R showed a nocturnal peak at 02:00 h (R = 2.87 ± 0.46; mean ± SEM) and diurnal trough 14:00 h (R = 1.30 ± 0.05) (t test, p < .02); clock-time-related changes in R were further validated by ANOVA (p = .0001) and Cosinor (p < .0001), with acrophase (peak time, Ø) of 02:43 h ± 68 min (SD). The second aim of the study was to evaluate the relationship between the 24-h patterns of WRIs and lag-time (LT) response (used as a measure of work performance) of FM of the same service to urgent medical calls for out-of-hospital cardiac arrests. Highest R of WRI at 02:00 h corresponded closely to longest LT (raw data at ∼02:00 h and Cosinor derived Ø of 02.54 h ± 71 min [SD]), thereby supporting the hypothesis of a common mechanism underlying the two 24-h profiles. A third aim was to determine the relevance of a new concept in work safety, "chronoprevention," for future FM training programs.

  17. Mothers' Maximum Drinks Ever Consumed in 24 Hours Predicts Mental Health Problems in Adolescent Offspring

    ERIC Educational Resources Information Center

    Malone, Stephen M.; McGue, Matt; Iacono, William G.

    2010-01-01

    Background: The maximum number of alcoholic drinks consumed in a single 24-hr period is an alcoholism-related phenotype with both face and empirical validity. It has been associated with severity of withdrawal symptoms and sensitivity to alcohol, genes implicated in alcohol metabolism, and amplitude of a measure of brain activity associated with…

  18. The Success of Surgery in the First 24 Hours in Patients with Esophageal Perforation

    PubMed Central

    Bayram, Ahmet Sami; Erol, Mehmet Muharrem; Melek, Huseyin; Colak, Mehmet Ali; Kermenli, Tayfun; Gebitekin, Cengiz

    2015-01-01

    Objective: Esophageal perforation (EP) is a critical and potentially life-threatening condition with considerable rates of morbidity and mortality. Despite many advances in thoracic surgery, the management of patients with EP is still controversial. Materials and Methods: We retrospectively reviewed 34 patients treated for EP, 62% male, mean age 53.9 years. Sixty-two percent of the EPs were iatrogenic. Spontaneous and traumatic EP rates were 26% and 6%, respectively. Three patients had EP in the cervical esophagus and 31 in the thoracic esophagus. Results: Mean time to initial treatment was 34.2 hours. Twenty patients comprised the early group <24 h) and 14 patients the late group (>24 h). Management of the EP included primary closure in 30 patients, non-surgical treatment in two, stent in one and resection in one. Mortality occurred in nine of the 34 patients (26%). Mortality was EP-related in four patients. Three of the nine patients that died were in the early group (p<0.05). Mean hospital stay was 13.4 days. Conclusion: EP remains a potentially fatal condition and requires early diagnosis and accurate treatment to prevent the morbidity and mortality. PMID:25745344

  19. Specific Antivenom Ability in Neutralizing Hepatic and Renal Changes 24 Hours after Latrodectus dahli Envenomation

    PubMed Central

    Valikhanfard-Zanjani, Elham; Zare-Mirakabadi, Abbas; Oryan, Shahrbanoo; Goodarzi, Hamid Reza; Rajabi, Mahdise

    2016-01-01

    Background: Latrodectism, a syndrome caused by Latrodectus genus, is one of the clinical problems that occur predominantly in north east of Iran. Nowadays antivenom therapy has become the most useful treatment for animal bites; however there is still a controversy about route and time of antivenom administration in spider bite. The aim of the present study was to determine the efficacy of specific antivenom in neutralizing hepatic and renal symptoms 24 h after Latrodectus dahli envenomation. Methods: We selected a group of male New Zealand white rabbits, weighing 2±0.3 kg. The L. dahli venom (0.5 mg/kg) was injected subcutaneously. Specific antivenom (2.5 ml, I.V) was injected 24 h following venom injection. Blood sampling was performed before and 24 h after venom injection, as well within 24, 48 and 72 h after antivenom administration. Serum levels of (aspartate amino transferase (AST) alanine amino transferase (ALT), alkaline phosphatase (ALP), urea, bilirubin, creatinine and albumin were determined in all the sam. Results: Latrodectus dahli venom caused significant increase (P< 0.05) in all foresaid serum parameters. Antivenom reversed the AST, ALP, creatinine, urea and bilirubin to normal levels, but failed about ALT level, also non-significant decrease was observed in albumin levels. Conclusion: Antivenom administration 24 h after venom injection can greatly reverse symptoms caused by venom. Future studies in human beings should be conducted to assess the protection against the specific-Latrodectus anti-venom. PMID:27308281

  20. 24 Hours in the Children's Section: An Observational Study at the Public Library

    ERIC Educational Resources Information Center

    Becker, Katherine

    2012-01-01

    The purpose of this study was to explore patronage and usage of the children's section of a public library. Patrons of the children's section of a public library in a small Northern Arizona city were observed for a total of 24 h over 12 sessions. Analytic induction was used to formulate categories based on field notes made during these…

  1. Influence of mild cold on the components of 24 hour thermogenesis in rats.

    PubMed Central

    Brown, D; Livesey, G; Dauncey, M J

    1991-01-01

    1. The influence of two weeks' acclimation to either 28 degrees C (thermal neutrality) or 21 degrees C (mild cold) on 24 h heat production and motor activity has been investigated in male Wistar rats. Food intake was controlled and provided as a single meal of approximately 170 kJ per day. Mathematical modelling was used to relate metabolic rate to measured movement and time of day. 2. For animals at thermal neutrality it was clear that metabolic rate increased during periods of substantial measured movement and returned to baseline during periods of minimal activity. Total heat production could therefore be divided into two components: underlying and movement-induced thermogenesis. 3. At 21 degrees C, a more complex model was needed. During periods of substantial activity, the relation between metabolic rate and movement was similar to that at 28 degrees C and total heat production could be divided into the same two components of underlying and movement-induced thermogenesis. However, during periods of prolonged inactivity, a different model was required, which included a component of extra metabolic activity, termed supplementary thermogenesis. By fitting this model to data at 28 and 21 degrees C, it was possible to partition 24 h heat production into the three possible sources of underlying, movement-induced and supplementary thermogenesis. 4. Total 24 h heat production was approximately 25% higher for rats at 21 compared with 28 degrees C (P less than 0.01) and underlying thermogenesis was approximately 20% higher for those in the mild cold (P less than 0.01). Measured movement was significantly reduced in the mild cold (P less than 0.05) although it was energetically less efficient since there was no difference in movement-induced thermogenesis, which accounted for 18 and 15% of total heat production at 28 and 21 degrees C respectively. Supplementary thermogenesis was observed only in the mild cold and it accounted for approximately 6% of 24 h heat production, while the peak value accounted for 20% of total heat production. Circadian variations in thermogenesis were also different at 28 compared with 21 degrees C. Possible mechanisms accounting for the components of underlying thermogenesis and supplementary thermogenesis are discussed. PMID:1816371

  2. Psychogenetically selected (Roman high- and low-avoidance) rats differ in 24-hour sleep organization.

    PubMed

    Steimer, T; Python, A; Driscoll, P; de Saint Hilaire, Z

    1999-06-01

    A comparison of sleep organization in Roman high-(RHA/Verh) and low-(RLA/Verh) avoidance rats, which differ in the way they respond to environmental stimuli and in several neuroendocrine and neurochemical parameters, was carried out. EEG-sleep recordings were obtained from adult males over 12:12 light-dark periods to determine how these two psychogenetically selected rat lines might also differ in their sleep-wake cycle. There was no significant difference in total sleep time between the two lines. However, the (hypoemotional) RHA/Verh rats showed an overall increase (percentage of total sleep) in paradoxical sleep (PS) duration, with a concomitant decrease in slow-wave sleep (SWS). During the dark phase, RHA/Verh rats showed a shorter PS latency and a larger number of PS episodes. Hourly sleep scoring also revealed a more discontinuous pattern (total sleep and PS vs. SWS) during the dark phase in RHA/Verh rats. In relation to recognized neurochemical and neuroendocrine differences between them, these rat lines may prove useful in investigations of the neurobiological mechanisms underlying sleep regulation. PMID:10452334

  3. Moderate alcohol consumption and 24-hour urinary levels of melatonin in postmenopausal women

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Low overnight urinary melatonin metabolite concentrations have been associated with increased risk for breast cancer among postmenopausal women. The Postmenopausal Women's Alcohol Study was a controlled feeding study to test the effects of low to moderate alcohol intake on potential risk factors for...

  4. Time course analysis of gene expression over 24 hours in Fe-deficient barley roots.

    PubMed

    Nagasaka, Seiji; Takahashi, Michiko; Nakanishi-Itai, Reiko; Bashir, Khurram; Nakanishi, Hiromi; Mori, Satoshi; Nishizawa, Naoko K

    2009-03-01

    Typical for a graminaceous plant, barley secretes mugineic acid-family phytosiderophores (MAs) to acquire iron (Fe). Under Fe-deficient conditions, MAs secretion from barley roots increases markedly. Secretion shows a diurnal pattern, with a clear peak 2-3 h after sunrise and cessation within a few hours. Microarray analyses were performed to profile the Fe deficiency-inducible genes in barley roots and diurnal changes in the expression of these genes. Genes encoding enzymes involved in MAs biosynthesis, the methionine cycle, and methionine biosynthesis were highly induced by Fe deficiency. The expression of sulfate transporters was also upregulated by Fe deficiency. Therefore, all of the genes participating in the MAs pathway from sulfur uptake and assimilation to the biosynthesis of MAs were upregulated in Fe-deficient barley roots. In contrast to MAs secretion, the transcript levels of these genes did not show diurnal changes. The amount of endogenous MAs gradually increased during the day after MAs secretion ceased, and was highest before secretion began. These results show that MAs biosynthesis, including the supply of the substrate methionine, occurs throughout the day, and biosynthesized MAs likely accumulate in barley roots until their secretion into the rhizosphere. In contrast, the levels of transcripts encoding an Fe(III)-MAs complex transporter, two putative metal-MAs complex transporters, and HvYS1 were also increased in Fe-deficient barley roots, and the levels of two of these transcripts showed diurnal rhythms. The Fe(III)-MAs complex transporters may absorb Fe(III)-MAs diurnally, synchronous with the diurnal secretion of MAs. PMID:19089316

  5. Effect of cimetidine on 24-hour intragastric acidity in normal subjects.

    PubMed Central

    Pounder, R E; Williams, J G; Milton-Thompson, G J; Misiewicz, J J

    1976-01-01

    The effect of H2-receptor blockade on intragastric acidity was studied in nine normal males. The pH of their gastric contents was measured at hourly daytime and two hourly nighttime intervals for 48 hours. The subjects ate identical meals, drank identical volumes of fluid, and smoked the same number of cigarettes during the two study days. Their physical activity was unrestricted in a ward environment. Blood cimetidine and plasma gastrin were measured in serial blood samples. The nine subjects were treated in random sequence with cimetidine 0-8-1-0 g on one day and placebo capsules on the other. The drug was given in four divided doses: four subjects received it before, and five after, the three main meals. All took the fourth dose at bedtime. Replicate studies in an additional subject given placebo on both study days showed good reproducibility (r=0-80, P less than 0-01). Cimetidine therapy decreased intragastric acidity in all nine subjects. The decrease was similar in the two groups taking the drug before or after meals, mean 24 h intragastric hydrogen ion activity being lowered by 70 and 72% respectively. Nocturnal anacidity was recorded in only two of 45 samples. Administration of cimetidine before meals produced earlier and higher drug blood levels than post-prandial medication, but when it was taken after food the blood levels were highest at the time when the buffer capacity of the food was waning. Blood concentrations of cimetidine exceeded the secretory IC50 level for most of the time between doses. The results show that cimetidine 0-8-1-0 g/day in four divided doses produces a striking and consistent decrease of intragastric acidity. Although variation in the timing of the dose in relation to meals did not affect the decrease of acidity, the absorption data suggest that patients should take the drug after meals. PMID:4361

  6. Fluid and electrolyte balance during 24-hour fluid and/or energy restriction.

    PubMed

    James, Lewis J; Shirreffs, Susan M

    2013-12-01

    Weight categorized athletes use a variety of techniques to induce rapid weight loss (RWL) in the days leading up to weigh in. This study examined the fluid and electrolyte balance responses to 24-hr fluid restriction (FR), energy restriction (ER) and fluid and energy restriction (F+ER) compared with a control trial (C), which are commonly used techniques to induce RWL in weight category sports. Twelve subjects (six male, six female) received adequate energy and water (C) intake, adequate energy and restricted water (~10% of C; FR) intake, restricted energy (~25% of C) and adequate water (ER) intake or restricted energy (~25% of C) and restricted (~10% of C) water intake (F+ER) in a randomized counterbalanced order. Subjects visited the laboratory at 0 hr, 12 hr, and 24 hr for blood and urine sample collection. Total body mass loss was 0.33% (C), 1.88% (FR), 1.97% (ER), and 2.44% (F+ER). Plasma volume was reduced at 24 hr during FR, ER, and F+ER, while serum osmolality was increased at 24 hr for FR and F+ER and was greater at 24 hr for FR compared with all other trials. Negative balances of sodium, potassium, and chloride developed during ER and F+ER but not during C and FR. These results demonstrate that 24 hr fluid and/ or energy restriction significantly reduces body mass and plasma volume, but has a disparate effect on serum osmolality, resulting in hypertonic hypohydration during FR and isotonic hypohydration during ER. These findings might be explained by the difference in electrolyte balance between the trials.

  7. Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Weidhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    2000-01-01

    BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, p<0.05) while plasma osmolality remained unchanged (NS). Pre-exercise Tre was elevated after HDT24 (36.71 degrees C +/-0.06 HDT1 vs. 36.93 degrees C+/-0.11 HDT24, p<0.05). The 70 min of exercise did not alter this relationship (p<0.05) with respective end exercise increases in Tre to 38.01 degrees C and 38.26 degrees C (degrees = 1.30 degrees C (HDT1) and 1.33 degrees C (HDT24)). While there were no pre-exercise differences in mean skin temperature (Tsk), a significant (p<0.05) time x treatment interaction occurred during exercise: after min 30 in HDT24 the Tsk leveled off at 31.1 degrees C, while it continued to increase reaching 31.5 degrees C at min 70 in HDT1. A similar response (NS) occurred in skin blood velocity. Neither local sweating rates nor changes in body weight during exercise of -1.63+/-0.24 kg (HDT1) or - 1.33+/-0.09 kg (HDT24) were different (NS) between experiments. CONCLUSION: While HDT24 resulted in elevated pre-exercise Tre, reduced PV, attenuation of Tsk and skin blood velocity during exercise, the absolute increase in exercise Tre was not altered. But if sweat rate and cutaneous vascular responses were similar at different core temperatures (unchanged thermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.

  8. Habitual sleep length and patterns of recovery sleep after 24 hour and 36 hour sleep deprivation.

    PubMed

    Benoit, O; Foret, J; Bouard, G; Merle, B; Landau, J; Marc, M E

    1980-12-01

    Five long sleepers (LS) and 5 short sleepers (SS) were selected from 310 medical students. Nine regular sleepers (RS) were used as a control. The sleep was recorded during 3 reference nights, one recovery night after a 36 h sleep deprivation (R2), one morning sleep after a 24 h sleep deprivation (D1) and the night following D1(R1). According to previous data slow wave sleep (SWS) amounts were the same in the 3 groups while stage 2 and paradoxical sleep (PS) amounts increased with the sleep duration. The hourly distribution of intervening wakefulness and SWS were similar for all groups. When compared to RS or SS the hourly distribution in LS of PS was lower until the sixth hour. As a function of experimental conditions, sleep patterns of LS were the most affected. In R2 the sleep of LS more closely resembled that of RS or SS than in reference nights, while in R1 LS' sleep was the most disturbed. Morning sleep durations were very similar for all groups, but in LS intervening wakefulness was increased and PS was decreased when compared to RS and SS. Negative correlations (Spearman rank test) were found between the morning increase of body temperature after a sleep-deprived night and both TST and PS durations. In all recorded sleep periods, SWS amounts were positively correlated with prior wakefulness duration and the PS amount with TST. PMID:6160990

  9. The 24-hour growth hormone secretion in a boy with giantism.

    PubMed

    Hindmarsh, P C; Pringle, P J; Brook, C G

    1988-03-01

    The endocrinological and radiological findings in a 7.5-year-old boy with giantism are reported and compared with an age and sex matched normal tall boy. A 24-h GH profile demonstrated a persistently elevated GH concentration (mean GH concentration: giant 19.3 mU/l; tall boy 5.4 mU/l) with loss of the dominant GH periodicity of 3 h seen in the boy with tall stature and substitution with one of 8 h. These data support the view that giantism and acromegaly are similar diseases occurring prior to and following epiphyseal fusion, respectively. PMID:3132796

  10. Recovery of function after vagus nerve stimulation initiated 24 hours after fluid percussion brain injury.

    PubMed

    Smith, Douglas C; Tan, Arlene A; Duke, Andrea; Neese, Steven L; Clough, Richard W; Browning, Ronald A; Jensen, Robert A

    2006-10-01

    Recent evidence from our laboratory demonstrated in laboratory rats that stimulation of the vagus nerve (VNS) initiated 2 h after lateral fluid percussion brain injury (FPI) accelerates the rate of recovery on a variety of behavioral and cognitive tests. VNS animals exhibited a level of performance comparable to that of sham-operated uninjured animals by the end of a 2-week testing period. The effectiveness of VNS was further evaluated in the present study in which initiation of stimulation was delayed until 24 h post-injury. Rats were subjected to a moderate FPI and tested on the beam walk, skilled forelimb reaching, locomotor placing, forelimb flexion and Morris water maze tasks for 2 weeks following injury. VNS (30 sec trains of 0.5 mA, 20.0-Hz biphasic pulses) was initiated 24 h post-injury and continued at 30-min intervals for the duration of the study, except for brief periods when the animals were detached for behavioral assessments. Consistent with our previous findings when stimulation was initiated 2 h post-injury, VNS animals showed significantly faster rates of recovery compared to controls. By the last day of testing (day 14 post-injury), the FPI-VNS animals were performing significantly better than the FPI-no-VNS animals and were not significantly different from shams in all motor and sensorimotor tasks. Performance in the Morris water maze indicated that the VNS animals acquired the task more rapidly on days 11-13 post-injury. On day 14, the FPI-VNS animals did not differ in the latency to find the platform from sham controls, whereas the injured controls did; however, the FPI-VNS animals and injured controls were not significantly different. Despite the lack of significant histological differences between the FPI groups, VNS, when initiated 24 h following injury, clearly attenuated the ensuing behavioral deficits and enhanced acquisition of the cognitive task. The results are discussed with respect to the norepinephrine hypothesis. PMID:17020489

  11. Stability, precision, and near-24-hour period of the human circadian pacemaker

    NASA Technical Reports Server (NTRS)

    Czeisler, C. A.; Duffy, J. F.; Shanahan, T. L.; Brown, E. N.; Mitchell, J. F.; Rimmer, D. W.; Ronda, J. M.; Silva, E. J.; Allan, J. S.; Emens, J. S.; Dijk, D. J.; Kronauer, R. E.

    1999-01-01

    Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.

  12. Design of solar thermal dryers for 24-hour food drying processes (abstract)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Solar drying is a ubiquitous method that has been adopted for many years as a food preservation method. Most of the published articles in the literature provide insight on the performance of solar dryers in service but little information on the dryer construction material selection process or mater...

  13. Effect of 16 and 24 hours daily radiation (light) on lettuce growth

    NASA Technical Reports Server (NTRS)

    Koontz, H. V.; Prince, R. P.; Knott, W. M. (Principal Investigator)

    1986-01-01

    A 50% increase in total radiation by extending the photoperiod from 16 to 24 hr doubled the weight of all cultivars of loose-leaf lettuce (Lactuca sativa L.) 'Grand Rapids Forcing', 'Waldmanns Green', 'Salad Bowl', and 'RubyConn', but not a Butterhead cultivar, 'Salina'. When total daily radiation (moles of photons) was the same, plants under continuous radiation weighed 30% to 50% more than plants under a 16 hr photoperiod. By using continuous radiation on loose-leaf lettuce, fewer lamp fixtures were required and yield was increased.

  14. Design of solar thermal dryers for 24-hour food drying processes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Solar drying is a method that has been adopted for many years as a food preservation method. To this date, significant advancements have been made in this field with the adoption of a multitude of solar thermal dryer designs for single-layer and multi-layer drying of fruit and vegetables e.g. cabine...

  15. Authenticated Tracking and Monitoring System (ATMS) tracking shipments from an Australian uranium mine

    SciTech Connect

    Schoeneman, J.L.; Sorokowski, D.

    1997-10-01

    The Authenticated Tracking and Monitoring System (ATMS) answers the need for global monitoring of the status and location of sensitive items on a worldwide basis, 24 hours a day. The ATMS concept uses wireless sensor packs to monitor the status of the items and environmental conditions, to collect a variety of sensor event data, and to transmit the data through the INMARSAT satellite communication system, which then sends that data to appropriate ground stations for tracking and monitoring. Authentication and encryption algorithms are used throughout the system to secure the data during communication activities. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements.

  16. QT dispersion and ventricular arrhythmias in children with primary mitral valve prolapse

    PubMed Central

    İmamoğlu, Ebru Yalın; Eroğlu, Ayşe Güler

    2016-01-01

    Aim: To investigate ventricular arrhythmias in children with primary mitral valve prolapse and to evaluate its relation with QT length, QT dispersion, autonomic function tests and heart rate variability measurements. Material and Methods: Fourty two children with mitral valve prolapse and 32 healthy children were enrolled into the study. Twelve-lead electrocardiograms, autonomic function tests, echocardiography and 24-hour rhythm Holter tests were performed. Electrocardiograms were magnified digitally. The QT length was corrected according to heart rate. The patients were grouped according to the number of premature ventricular contractions and presence of complex ventricular arhythmia in the 24-hour rhythm Holter monitor test. Heart rate variability measurements were calculated automatically from the 24-hour rhythm Holter monitor test. Orthostatic hypotension and resting heart rate were used as autonomic function tests. Results: The mean age was 13.9±3.3 years in the patient group and 14.6±3.1 years in the control group (p>0.05). Thirty four of the patients (81%) were female and eight (19%) were male. Twenty five of the control subjects (78%) were female and seven (22%) were male. The QT dispersion and heart rate corrected QT interval were found to be significantly increased in the children with primary mitral valve prolapse when compared with the control group (56±16 ms vs. 43±11 ms, p=0.001; 426±25 ms vs. 407±26 ms, p=0.002, respectively). In 24-hour rhythm Holter monitor tests, ventricular arrhythmias were found in 21 out of 42 patients (50%) and 6 out of 32 control subjects (18.8%) (p=0.006). QT dispersion was found to be significantly increased in patients with premature ventricular contractions ≥ 10/day and/or complex ventricular arrhythmias compared to the control group without ventricular premature beats (p=0.002). There was no significant difference in autonomic function tests and heart rate variability measurements between the patient and control

  17. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds. PMID:27312253

  18. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  19. Research and Development of Information and Communication Technology-based Home Blood Pressure Monitoring from Morning to Nocturnal Hypertension.

    PubMed

    Kario, Kazuomi; Tomitani, Naoko; Matsumoto, Yuri; Hamasaki, Haruna; Okawara, Yukie; Kondo, Maiko; Nozue, Ryoko; Yamagata, Hiromi; Okura, Ayako; Hoshide, Satoshi

    2016-01-01

    Asians have specific characteristics of hypertension (HTN) and its relationship with cardiovascular disease. The morning surge in blood pressure (BP) in Asians is more extended, and the association slope between higher BP and the risk for cardiovascular events is steeper in this population than in whites. Thus, 24-hour BP control including at night and in the morning is especially important for Asian patients with HTN. There are 3 components of "perfect 24-hour BP control": the 24-hour BP level, adequate dipping of nocturnal BP (dipper type), and adequate BP variability such as the morning BP surge. The morning BP-guided approach using home BP monitoring (HBPM) is the first step toward perfect 24-hour BP control. After controlling morning HTN, nocturnal HTN is the second target. We have been developing HBPM that can measure nocturnal BP. First, we developed a semiautomatic HBPM device with the function of automatic fixed-interval BP measurement during sleep. In the J-HOP (Japan Morning Surge Home Blood Pressure) study, the largest nationwide home BP cohort, we successfully measured nocturnal home BP using this device with data memory, 3 times during sleep (2, 3, and 4 am), and found that nocturnal home BP is significantly correlated with organ damage independently of office and morning BP values. The second advance was the development of trigger nocturnal BP (TNP) monitoring with an added trigger function that initiates BP measurements when oxygen desaturation falls below a variable threshold continuously monitored by pulse oximetry. TNP can detect the specific nocturnal BP surges triggered by hypoxic episodes in patients with sleep apnea syndrome. We also added the lowest heart rate-trigger function to TNP to detect the "basal nocturnal BP," which is determined by the circulating volume and structural cardiovascular system without any increase in sympathetic tonus. This double TNP is a novel concept for evaluating the pathogenic pressor mechanism of nocturnal BP

  20. Remote Physical Activity Monitoring in Neurological Disease: A Systematic Review

    PubMed Central

    Block, Valerie A. J.; Pitsch, Erica; Tahir, Peggy; Cree, Bruce A. C.; Allen, Diane D.; Gelfand, Jeffrey M.

    2016-01-01

    Objective To perform a systematic review of studies using remote physical activity monitoring in neurological diseases, highlighting advances and determining gaps. Methods Studies were systematically identified in PubMed/MEDLINE, CINAHL and SCOPUS from January 2004 to December 2014 that monitored physical activity for ≥24 hours in adults with neurological diseases. Studies that measured only involuntary motor activity (tremor, seizures), energy expenditure or sleep were excluded. Feasibility, findings, and protocols were examined. Results 137 studies met inclusion criteria in multiple sclerosis (MS) (61 studies); stroke (41); Parkinson's Disease (PD) (20); dementia (11); traumatic brain injury (2) and ataxia (1). Physical activity levels measured by remote monitoring are consistently low in people with MS, stroke and dementia, and patterns of physical activity are altered in PD. In MS, decreased ambulatory activity assessed via remote monitoring is associated with greater disability and lower quality of life. In stroke, remote measures of upper limb function and ambulation are associated with functional recovery following rehabilitation and goal-directed interventions. In PD, remote monitoring may help to predict falls. In dementia, remote physical activity measures correlate with disease severity and can detect wandering. Conclusions These studies show that remote physical activity monitoring is feasible in neurological diseases, including in people with moderate to severe neurological disability. Remote monitoring can be a psychometrically sound and responsive way to assess physical activity in neurological disease. Further research is needed to ensure these tools provide meaningful information in the context of specific neurological disorders and patterns of neurological disability. PMID:27124611

  1. Dynamic magnetic resonance monitoring of interstitial laser photocoagulation of hepatic metastases from a colorectal tumor

    NASA Astrophysics Data System (ADS)

    Roberts, Hugh R.; Paley, Martyn; Buonaccorsi, Giovanni A.; Clemence, Matthew; Friedman, Emma P.; Allen, Clare; Hall-Craggs, Margret A.; Lees, William R.; Bown, Stephen G.

    1994-12-01

    Interstitial laser photocoagulation (ILP) is becoming an established treatment for hepatic metastases. Per-procedural ultrasound does not accurately define the tissue coagulated and dynamic computed tomography, while an accurate form of assessment, must be delayed until 24 hours after therapy; it too is, therefore, no use for per-procedural confirmation of total tumor ablation. By virtue of its good contrast, spatial and temporal resolution and the fact that T1 weighted images are temperature sensitive magnetic resonance imaging (MRI) is, theoretically, applicable to the per-procedural guidance of ILP. Our ex vivo porcine, and in vivo rat liver experiments showed good imaging-pathological agreement. We have treated with ILP two patients suffering from hepatic metastases using MRI guidance. Four to eight 400 micrometers optical fibers were passed through the lesion down Teflon sheaths under local anaesthetic and intravenous sedation using ultrasound guidance. Sets of 400 second laser burns at 1.5 - 2.0 W per fiber were then performed, with a 1 cm fiber withdrawal between each set, until the entire tumor had been coagulated. Therapy was monitored with dynamic MRI using a T1 weighted FLASH sequence. MRI showed an enlarging bright rimmed low signal area which correlated with the region of devascularization seen on enhanced helical computed tomography at 24 hours. MRI can monitor ILP of hepatic metastases and confirm tumor ablation at the time of treatment.

  2. Microseismic monitoring of the Chaveroo oil field, New Mexico

    SciTech Connect

    Rutledge, J.T.; Albright, J.N.; Fairbanks, T.D.; Murphy, M.B.; Roberts, P.M.

    1990-01-01

    Induced microseismicity was monitored in the Chaveroo oil field in southeastern New Mexico during a pressurized stimulation of a well being prepared as an injector for a waterflood operation. In addition, the microseismicity was monitored for 5 weeks following the stimulation while the area was under normal waterflood production. Little seismicity was detected during the 5.5 hour stimulation in which three thousand barrels of water were injected into the reservoir at pressures ranging from 96 to 257 bars in excess of hydrostatic pressure. Intermittent monitoring over the 5-week period indicated detectable seismicity occurred during waterflood production. Monitoring during the 5 weeks, however, was not complete enough to draw general conclusions on temporal variations of observed microseismicity. Seventy-three good quality events recorded over a cumulative 24 hours of intermittent monitoring were located using the hodogram technique. Events were detected at distances up to 1700 m from the monitor well but most occurred within 900 m. The map of microearthquake locations indicated that events occurred in the vicinity of producing wells and away from injection wells. The first half of the sequence of mappable events occurred along linear trends, but the pattern became more scattered during the later half of the sequence. The lack of seismicity during the pressurized injection and the increased seismicity levels occurring away from injection wells during waterflood production, suggest seismicity is not induced by Mohr-Coulomb failure. 6 refs., 6 figs.

  3. Heart-rate monitoring by air pressure and causal analysis

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Naoki; Nakajima, Hiroshi; Hata, Yutaka

    2011-06-01

    Among lots of vital signals, heart-rate (HR) is an important index for diagnose human's health condition. For instance, HR provides an early stage of cardiac disease, autonomic nerve behavior, and so forth. However, currently, HR is measured only in medical checkups and clinical diagnosis during the rested state by using electrocardiograph (ECG). Thus, some serious cardiac events in daily life could be lost. Therefore, a continuous HR monitoring during 24 hours is desired. Considering the use in daily life, the monitoring should be noninvasive and low intrusive. Thus, in this paper, an HR monitoring in sleep by using air pressure sensors is proposed. The HR monitoring is realized by employing the causal analysis among air pressure and HR. The causality is described by employing fuzzy logic. According to the experiment on 7 males at age 22-25 (23 on average), the correlation coefficient against ECG is 0.73-0.97 (0.85 on average). In addition, the cause-effect structure for HR monitoring is arranged by employing causal decomposition, and the arranged causality is applied to HR monitoring in a setting posture. According to the additional experiment on 6 males, the correlation coefficient is 0.66-0.86 (0.76 on average). Therefore, the proposed method is suggested to have enough accuracy and robustness for some daily use cases.

  4. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study.

    PubMed

    Gargiulo, Gaetano D; O'Loughlin, Aiden; Breen, Paul P

    2015-02-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need.In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial.

  5. Noninvasive intraocular pressure monitoring: current insights

    PubMed Central

    De Smedt, Stefan

    2015-01-01

    Glaucoma is the second leading cause of blindness worldwide and intraocular pressure (IOP) is currently its only modifiable risk factor. Peak IOP has for a long time been considered as a major contributor to glaucoma progression, but its effects may depend not only on its magnitude, but also on its time course. The IOP is nowadays considered to be a dynamic parameter with a circadian rhythm and spontaneous changes. The current practice of punctual measuring the IOP during office hours is therefore a suboptimal approach, which does not take into account the natural fluctuation of IOP. Because of its static nature a single IOP measurement in sitting position fails to document the true range of an individual’s IOP, peak IOP, or variation throughout the day. Phasing means monitoring a patient’s IOP during the daytime or over a 24-hour period. This can provide additional information in the management of glaucoma patients. This review focuses on the current insight of non-invasive IOP monitoring as a method of obtaining more complete IOP profiles. Invasive techniques using an implantable sensor are beyond the scope of this review. PMID:26257509

  6. Anticoagulation: monitoring of patients receiving anticoagulation.

    PubMed

    Hawes, Emily M; Viera, Anthony J

    2014-07-01

    For patients with acute venous thromboembolism treated with warfarin, parenteral anticoagulation should be continued for a minimum of 5 days and until the international normalized ratio (INR) is 2 or greater for at least 24 hours. Early initiation of warfarin therapy is recommended. The goal therapeutic INR range for patients treated with warfarin is most commonly 2 to 3. During maintenance warfarin therapy, validated decision-support tools should be used to guide dosing. For patients with stable INRs, frequency of INR testing can be extended from every 4 weeks to up to 12 weeks. Self-testing and self-management can be safe options for patients receiving warfarin who are motivated and show competence. Patients starting anticoagulation therapy should receive education on treatment goals, adverse effects, and monitoring strategy. Physicians deciding whether to prescribe one of the new oral anticoagulants instead of warfarin should assess for possible drug interactions and for renal and hepatic impairment and should consider the financial cost to the patient. No routine coagulation assay monitoring is required for patients receiving apixaban, dabigatran, or rivaroxaban. Physicians who oversee oral anticoagulation therapy should do so in a systematic and coordinated fashion.

  7. Real-time optoacoustic monitoring of stroke

    NASA Astrophysics Data System (ADS)

    Kneipp, Moritz; Turner, Jake; Hambauer, Sebastian; Krieg, Sandro M.; Lehmberg, Jens; Lindauer, Ute; Razansky, Daniel

    2014-03-01

    Characterizing disease progression and identifying possible therapeutic interventions in stroke is greatly aided by the use of longitudinal function imaging studies. In this study, we investigate the applicability of real-time multispectral optoacoustic tomography (MSOT) as a tool for non-invasive monitoring of the progression of stroke in the whole brain. The middle cerebral artery occlusion (MCAO) method was used to induce stroke. Mice were imaged under isoflurane anesthesia preoperatively and at several time points during and after the 60-minute occlusion. The animals were sacrificed after 24 hours and their excised brains frozen at -80°C for sectioning. The cryosection were stained using H&E staining to identify the ischemic lesion. Major vessels are readily identifiable in the whole mouse head in the in vivo optoacoustic scans. During ischemia, a reduction in cerebral blood volume is detectable in the cortex. Post ischemia, spectral unmixing of the optoacoustic signals shows an asymmetry of the deoxygenated hemoglobin in the hemisphere affected by MCAO. This hypoxic area was mainly located around the boundary of the ischemic lesion and was therefore identified as the ischemic penumbra. Non-invasive functional MSOT imaging is able to visualize the hypoxic penumbra in brains affected by stroke. Stopping the spread of the infarct area and revitalizing the penumbra is central in stroke research, this new imaging technique may therefore prove to be a valuable tool in the monitoring and developing new treatments.

  8. Short and Long-Term Effect of Carotid Artery Stenting on Arterial Blood Pressure Measured through Ambulatory Blood Pressure Monitoring

    PubMed Central

    Köklü, Erkan; Yüksel, İsa Öner; Arslan, Şakir; Bayar, Nermin; Köklü, Fatma; Çay, Serkan; Çağırcı, Göksel; Küçükseymen, Selçuk; Kuş, Görkem

    2016-01-01

    Background The aim of this study was to assess the short and long-term effects of carotid artery stenting (CAS) procedure on blood pressure (BP) through ambulatory BP monitoring. Methods One hundred fifty three patients who underwent CAS for primary or secondary protection from December 2010 to September 2013 were enrolled to our study. The BP levels of total of 123 patients were monitored for 1 year. Thereafter, the pre-procedure levels of BP were compared with BP levels at the 24-hour and the first year intervals after the procedure. Results Systolic and diastolic BP levels at the 24-hour and the first year intervals after CAS were significantly lower than the pre-procedure BP levels. The mean 24-hour systolic BP was 113 ± 13 mmHg and diastolic BP was 63 ± 8 mmHg, both of which were significantly lower (p < 0.001 and p < 0.001 respectively), while the pre-procedure mean systolic BP was 133 ± 10 mmHg and the mean diastolic BP was 75 ± 9 mmHg. Moreover, the mean first-year systolic BP was 125 ± 10 mmHg with a decline of 8 ± 8 mmHg and mean diastolic BP was 71 ± 8 mmHg with a decline of 4 ± 7 mmHg, both of which were again significantly lower compared to the pre-procedure levels (p < 0.001 and p < 0.001 respectively). Conclusions The results of our study suggested that systolic and diastolic BP levels diminished after CAS. Additionally, BP reduction continued even 1 year after the CAS. PMID:27274176

  9. An integrated approach based on uniform quantization for the evaluation of complexity of short-term heart period variability: Application to 24 h Holter recordings in healthy and heart failure humans

    NASA Astrophysics Data System (ADS)

    Porta, A.; Faes, L.; Masé, M.; D'Addio, G.; Pinna, G. D.; Maestri, R.; Montano, N.; Furlan, R.; Guzzetti, S.; Nollo, G.; Malliani, A.

    2007-03-01

    We propose an integrated approach based on uniform quantization over a small number of levels for the evaluation and characterization of complexity of a process. This approach integrates information-domain analysis based on entropy rate, local nonlinear prediction, and pattern classification based on symbolic analysis. Normalized and non-normalized indexes quantifying complexity over short data sequences (˜300 samples) are derived. This approach provides a rule for deciding the optimal length of the patterns that may be worth considering and some suggestions about possible strategies to group patterns into a smaller number of families. The approach is applied to 24h Holter recordings of heart period variability derived from 12 normal (NO) subjects and 13 heart failure (HF) patients. We found that: (i) in NO subjects the normalized indexes suggest a larger complexity during the nighttime than during the daytime; (ii) this difference may be lost if non-normalized indexes are utilized; (iii) the circadian pattern in the normalized indexes is lost in HF patients; (iv) in HF patients the loss of the day-night variation in the normalized indexes is related to a tendency of complexity to increase during the daytime and to decrease during the nighttime; (v) the most likely length L =3 indicates that stable patterns (i.e., those with no variations) are more present during the daytime, while highly variable patterns (i.e., those with two unlike variations) are more frequent during the nighttime; (vii) during the daytime in HF patients, the percentage of highly variable patterns increases with respect to NO subjects, while during the nighttime, the percentage of patterns with one or two like variations decreases.

  10. [Clinical evaluation of ECG at the onset subjective symptoms using real-time analysis electrocardiograph (event recorder)].

    PubMed

    Takizawa, Yoshinori; Shimetani, Naoto; Uchiyama, Kenji; Takayanagi, Kan; Mori, Mikio

    2005-05-01

    Examination of patient complaining of palpitation, chest pain and chest discomfort is usually performed by 12-lead electrocardiograph. However, the recording time is short and there are few opportunities to capture an ECG demonstrating conditions during subjective symptoms. To investigate the cause, we need to obtain an ECG during subjective symptoms. Thus, we frequently use a Holter ECG, which can be recorded for 24 hours. However, some patients have a low frequency of subjective symptoms, which may not appear during a 24-hour examination. We used a real-time electrocardiograph (Event Recorder CG-6106 made by Card Guard Scientific Survival Limited) as a monitor during subjective symptoms. Thereafter, ECG findings at the onset of subjective symptoms could be analyzed in 30 patients who did not have a clear cardiac disease. In this examination, arrhythmia was recorded in 25 of 30 cases. Although in these cases ECG during subjective symptoms could not be captured even when Holter examination was performed several times ECG during subjective symptoms was captured using an Event Recorder. This method using an Event Recorder is simple and convenient, moreover, is considered very useful for investigation of subjective symptoms. In the future, the use of an Event Recorder for heart-health-care in the daily life of healthy people and/or cardiac disease patient is highly anticipated.

  11. Chronic Management of Hypertension after Stroke: The Role of Ambulatory Blood Pressure Monitoring

    PubMed Central

    Castilla-Guerra, Luis; Fernandez-Moreno, Maria del Carmen

    2016-01-01

    Hypertension is the most important potentially reversible risk factor for stroke in all age groups; high blood pressure (BP) is also associated with increased risk of recurrent stroke in patients who have already had an ischemic or hemorrhagic event. Twenty-four hour ambulatory BP monitoring (ABPM) has become an important tool for improving the diagnosis and management of hypertension, and is increasingly used to assess patients with hypertension. Nevertheless, although ABPM devices are increasingly used for assessment of hypertension, their value in the chronic management of hypertension in patients with stroke has not been systematically studied. In fact, among large-scale randomized trials for secondary stroke prevention, only the Morbidity and Mortality After Stroke, Eprosartan Compared With Nitrendipine for Secondary Prevention trial included 24-hour ABPM. ABPM has demonstrated chronic disruption of the circadian rhythm of BP after acute phase of stroke and has shown higher sensitivity compared to office BP in evaluating the effectiveness of antihypertensive treatment among stroke survivors. High 24-hour BP is an independent predictor for cerebrovascular events, brain microbleeds, and subsequent development of dementia. Nevertheless, although stroke care guidelines endorse the importance of hypertension management, the specific role of ABPM among stroke survivors after the acute phase of disease has not been established. Further studies are needed to clarify whether routine application of ABPM among these patients should be recommended. PMID:26687120

  12. [Design of the Mobile ECG Monitoring System Based on Android 4.3].

    PubMed

    Zhang, Shun; Lian, Yuxi; Qin, Yajie; Wang, Yuanyuan

    2015-07-01

    To monitor and record Electrocardiograph (ECG) signals for 24 hours, a mobile ECG monitoring system is designed based on Android 4.3. In this system, domestic indigenous E9622A is used to acquire ECG signals and TI CC2541 is adopted to communicate with mobile phones. The program is implemented on the Android platform to display and process ECG signals. The whole system is integrated on a 2 cm x 2 cm PCB. From experiments, it is shown that ECG signals can be obtained effectively when this system is worn, and clear ECG waveforms and parameters can be shown on the phones. With this system, arrhythmia can be diagnosed preliminarily. It is also shown that the system is low-power, low-cost, flexible and portable.

  13. Hawai'i air quality monitoring assessment: some effects of Hawai'i's smoke-free work and public places law.

    PubMed

    Pobutsky, Ann; Krupitsky, Dmitry; Kanja, Mildred Lum; Lipsher, Julian

    2008-06-01

    In November 2006, the Smoke-Free Work and Public Places Law passed to protect people from secondhand smoke in Hawai'i. An air-quality monitoring assessment to determine the difference this law made in air quality was conducted at 15 bars/restaurants. Levels of particulate matter (PM2.5) at enclosed (indoor) venues fell 90% after implementation of the law while partially enclosed restaurants/bars were all below the EPA 24 hour average limit both before and after the law. PMID:18678206

  14. International Remote Monitoring Project Argentina nuclear power station remote monitoring system

    SciTech Connect

    Schneider, S.L.; Lucero, R.; Glidewell, D.

    1998-08-01

    A remote monitoring system, designed to monitor spent fuel transfers from wet to dry storage, was installed at the Embalse Nuclear Power Station at Embalse, Argentina. The system consists of 6 gamma and one neutron radiation sensors. Five gamma sensors utilize RF transmission to communicate with Echelon nodes connected to a Local Operating Network (LON). One gamma and one neutron sensor are hardwired to the LON network. Each sensor Echelon node is bound to a single Datalogger that stores data until it receives an acquisition command to download to the Data Acquisition Software (DASW) database. The data from the Datalogger are transferred and stored in the Data Acquisition Software database, which resides on the IAEA MOS-MUX server. At a pre-determined interval, data from the DASW database are converted into Excel files and transferred to the IAEA database every 24 hours. At an predetermined interval all data are transferred to the distribution server located at the ARN laboratory at Ezeiza, Argentina. Remote access to data from the distribution server will be made from IAEA headquarters, Vienna, Austria, from ABACC in Rio de Janeiro, Brazil, from the IAEA field office in Buenos Aires, from ARN, and from Sandia National Laboratories, Albuquerque, New Mexico.

  15. Twenty four hour blood pressure monitoring in normal tension glaucoma.

    PubMed Central

    Meyer, J H; Brandi-Dohrn, J; Funk, J

    1996-01-01

    BACKGROUND: The few investigations that used continuous 24 hour blood pressure monitoring to investigate whether blood pressure in patients with normal tension glaucoma is lower than in normal subjects yielded conflicting results. Therefore, a prospective controlled trial was carried out. METHODS: Systemic blood pressure was recorded continuously over a 24 hour period in 20 patients with normal tension glaucoma (IOP < or = 21 mm Hg). Eight of them showed a localised loss of the neuroretinal rim area and, in addition, optic disc haemorrhages-that is, focal ischaemic signs. Twenty healthy patients without glaucoma, who were hospitalised for cataract or retinal surgery, served as controls. Blood pressure was automatically measured every 20 minutes during the day and every 40 minutes at night. RESULTS: Both groups showed a significant (physiological) blood pressure drop at night, which was significantly (p < 0.001, ANOVA) more pronounced in the group with normal tension glaucoma than in the control group. There was a weak trend towards lower blood pressure values in the normal tension glaucoma group. Minima, maxima, and mean values of the systolic, diastolic, and mean arterial pressures did not differ significantly between the group with normal tension glaucoma and the control group. The greatest differences occurred with nocturnal systolic and diurnal diastolic values. There were no significant differences between the subgroup with focal lesions and the other patients with normal tension glaucoma. CONCLUSIONS: Patients with normal tension glaucoma tend to have lower blood pressure values (p > 0.05, ANOVA) than normals; this difference is probably much smaller than formerly assumed. Patients with normal tension glaucoma, however, have significantly greater nocturnal blood pressure drops (p < 0.001, ANOVA) than normal controls. Nocturnal blood pressure drops (relative day-night differences) may play a more important role in the pathogenesis of normal tension glaucoma

  16. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    PubMed Central

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  17. New Methods for Personal Exposure Monitoring for Airborne Particles

    PubMed Central

    Koehler, Kirsten A.; Peters, Thomas

    2016-01-01

    Airborne particles have been associated with a range of adverse cardiopulmonary outcomes, which has driven its monitoring at stationary, central sites throughout the world. Individual exposures, however, can differ substantially from concentrations measured at central sites due to spatial variability across a region and sources unique to the individual, such as cooking or cleaning in homes, traffic emissions during commutes, and widely varying sources encountered at work. Personal monitoring with small, battery-powered instruments enables the measurement of an individual’s exposure as they go about their daily activities. Personal monitoring can substantially reduce exposure misclassification and improve the power to detect relationships between particulate pollution and adverse health outcomes. By partitioning exposures to known locations and sources, it may be possible to account for variable toxicity of different sources. This review outlines recent advances in the field of personal exposure assessment for particulate pollution. Advances in battery technology have improved the feasibility of 24-hour monitoring, providing the ability to more completely attribute exposures to microenvironment (e.g., work, home, commute). New metrics to evaluate the relationship between particulate matter and health are also being considered, including particle number concentration, particle composition measures, and particle oxidative load. Such metrics provide opportunities to develop more precise associations between airborne particles and health and may provide opportunities for more effective regulations. PMID:26385477

  18. Monitoring materials

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2002-01-01

    The apparatus and method provide techniques for effectively implementing alpha and/or beta and/or gamma monitoring of items or locations as desired. Indirect alpha monitoring by detecting ions generated by alpha emissions, in conjunction with beta and/or gamma monitoring is provided. The invention additionally provides for screening of items prior to alpha monitoring using beta and/or gamma monitoring, so as to ensure that the alpha monitoring apparatus is not contaminated by proceeding direct to alpha monitoring of a heavily contaminated item or location. The invention provides additional versatility in the emission forms which can be monitored, whilst maintaining accuracy and avoiding inadvertent contamination.

  19. Clinical significance of automatic warning function of cardiac remote monitoring systems in preventing acute cardiac episodes

    PubMed Central

    Chen, Shou-Qiang; Xing, Shan-Shan; Gao, Hai-Qing

    2014-01-01

    Objective: In addition to ambulatory Holter electrocardiographic recording and transtelephonic electrocardiographic monitoring (TTM), a cardiac remote monitoring system can provide an automatic warning function through the general packet radio service (GPRS) network, enabling earlier diagnosis, treatment and improved outcome of cardiac diseases. The purpose of this study was to estimate its clinical significance in preventing acute cardiac episodes. Methods: Using 2 leads (V1 and V5 leads) and the automatic warning mode, 7160 patients were tested with a cardiac remote monitoring system from October 2004 to September 2007. If malignant arrhythmias or obvious ST-T changes appeared in the electrocardiogram records was automatically transferred to the monitoring center, the patient and his family members were informed, and the corresponding precautionary or therapeutic measures were implemented immediately. Results: In our study, 274 cases of malignant arrhythmia, including sinus standstill and ventricular tachycardia, and 43 cases of obvious ST-segment elevation were detected and treated. Because of early detection, there was no death or deformity. Conclusions: A cardiac remote monitoring system providing an automatic warning function can play an important role in preventing acute cardiac episodes. PMID:25674124

  20. Monitoring the source monitoring.

    PubMed

    Luna, Karlos; Martín-Luengo, Beatriz

    2013-11-01

    The hypothesis that the retrieval of correct source memory cues, those leading to a correct source attribution, increases confidence, whereas the retrieval of incorrect source memory cues, those leading to a source misattribution, decreases confidence was tested. Four predictions were derived from this hypothesis: (1) confidence should be higher for correct than incorrect source attribution except; (2) when no source cues are retrieved; (3) only the source misattributions inferred from the retrieval of incorrect source cues will be rated with low confidence; and (4) the number of source cues retrieved, either correct or incorrect, will affect the confidence in the source attributions. To test these predictions, participants read two narratives from two witnesses to a bank robbery, a customer and a teller. Then, participants completed a source monitoring test with four alternatives, customer, teller, both, or neither, and rated their confidence in their source attribution. Results supported the first three predictions, but they also suggested that the number of correct source monitoring cues retrieved did not play a role in the monitoring of the accuracy of the source attributions. Attributions made from the recovery of incorrect source cues could be tagged as dubious or uncertain, thus leading to lowered confidence irrespective of the number of incorrect source cues or whether another correct source cue was also recovered. This research has potential applications for eyewitness memory because it shows that confidence can be an indicator of the accuracy of a source attribution. PMID:23553316

  1. Does home blood pressure monitoring improve patient outcomes? A systematic review comparing home and ambulatory blood pressure monitoring on blood pressure control and patient outcomes

    PubMed Central

    Breaux-Shropshire, Tonya L; Judd, Eric; Vucovich, Lee A; Shropshire, Toneyell S; Singh, Sonal

    2015-01-01

    Objective Our objective was to compare the clinical effectiveness of home blood pressure monitoring (HBPM) and 24-hour ambulatory blood pressure monitoring (ABPM) on blood pressure (BP) control and patient outcomes. Design A systematic review was conducted. We also appraised the methodological quality of studies. Data sources PubMed, Scopus, CINAHL, and the Cochrane Central Register of Control Trials (CENTRAL). Inclusion criteria Randomized control trials, prospective and retrospective cohort studies, observational studies, and case-control studies published in English from any year to present that describe HBPM and 24-hour ABPM and report on systolic and/or diastolic BP and/or heart attack, stroke, kidney failure and/or all-cause mortality for adult patients. Due to the nature of the question, studies with only untreated patients were not considered. Results Of 1,742 titles and abstractions independently reviewed by two reviewers, 137 studies met predetermined criteria for evaluation. Nineteen studies were identified as relevant and included in the paper. The common themes were that HBPM and ABPM correlated with cardiovascular events and mortality, and targeting HBPM or ABPM resulted in similar outcomes. Associations between BP measurement type and mortality differed by study population. Both the low sensitivity of office blood pressure monitoring (OBPM) to detect optimal BP control by ABPM and the added association of HBPM with cardiovascular mortality supported the routine use of HBPM in clinical practice. There was insufficient data to determine the benefit of using HBPM as a measurement standard for BP control. Conclusion HBPM encourages patient-centered care and improves BP control and patient outcomes. Given the limited number of studies with both HBPM and ABPM, these measurement types should be incorporated into the design of randomized clinical trials within hypertensive populations. PMID:26170715

  2. Improvements in atrial fibrillation detection for real-time monitoring.

    PubMed

    Babaeizadeh, Saeed; Gregg, Richard E; Helfenbein, Eric D; Lindauer, James M; Zhou, Sophia H

    2009-01-01

    Electrocardiographic (ECG) monitoring plays an important role in the management of patients with atrial fibrillation (AF). Automated real-time AF detection algorithm is an integral part of ECG monitoring during AF therapy. Before and after antiarrhythmic drug therapy and surgical procedures require ECG monitoring to ensure the success of AF therapy. This article reports our experience in developing a real-time AF monitoring algorithm and techniques to eliminate false-positive AF alarms. We start by designing an algorithm based on R-R intervals. This algorithm uses a Markov modeling approach to calculate an R-R Markov score. This score reflects the relative likelihood of observing a sequence of R-R intervals in AF episodes versus making the same observation outside AF episodes. Enhancement of the AF algorithm is achieved by adding atrial activity analysis. P-R interval variability and a P wave morphology similarity measure are used in addition to R-R Markov score in classification. A hysteresis counter is applied to eliminate short AF segments to reduce false AF alarms for better suitability in a monitoring environment. A large ambulatory Holter database (n = 633) was used for algorithm development and the publicly available MIT-BIH AF database (n = 23) was used for algorithm validation. This validation database allowed us to compare our algorithm performance with previously published algorithms. Although R-R irregularity is the main characteristic and strongest discriminator of AF rhythm, by adding atrial activity analysis and techniques to eliminate very short AF episodes, we have achieved 92% sensitivity and 97% positive predictive value in detecting AF episodes, and 93% sensitivity and 98% positive predictive value in quantifying AF segment duration. PMID:19608194

  3. Analysis of long term heart rate variability: methods, 1/f scaling and implications

    NASA Technical Reports Server (NTRS)

    Saul, J. P.; Albrecht, P.; Berger, R. D.; Cohen, R. J.

    1988-01-01

    The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.

  4. Spinal cord fusion with PEG-GNRs (TexasPEG): Neurophysiological recovery in 24 hours in rats

    PubMed Central

    Kim, C-Yoon; Sikkema, William K. A.; Hwang, In-Kyu; Oh, Hanseul; Kim, Un Jeng; Lee, Bae Hwan; Tour, James M.

    2016-01-01

    Background: The GEMINI spinal cord fusion protocol has been developed to achieve a successful cephalosomatic anastomosis. Here, for the first time, we report the effects of locally applied water-soluble, conductive PEG(polyethylene glycol)ylated graphene nanoribbons (PEG-GNRs) on neurophysiologic conduction after sharp cervical cord transection in rats. PEG-GNRs were produced by the polymerization of ethylene oxide from anion-edged graphene nanoribbons. These combine the fusogenic potential of PEG with the electrical conducting properties of the graphene nanoribbons. Methods: Laminectomy and transection of cervical spinal cord (C5) was performed on Female Sprague-Dawley (SD) rats. After applying PEG-GNR on the severed part, electrophysiological recovery of the reconstructed cervical spinal cord was confirmed by somatosensory evoked potentials (SSEPs) at 24 h after surgery. Results: While no SSEPs were detected in the control group, PEG-GNR treated group showed fast recovery of SSEPs at 24 h after the surgery. Conclusion: In this preliminary dataset, for the first time, we report the effect of a novel form of PEG with the goal of rapid reconstruction of a sharply severed spinal cord. PMID:27656326

  5. Effect of 24 hours light on circadian rhythms of secretory enzymes and morphology of rat von Ebner's glands.

    PubMed

    Field, R B; Redman, R S; Calloway, A M; Goldberg, W J

    1999-11-01

    Von Ebner's glands of the rat are minor salivary serous glands in the posterior portion of the tongue. They secrete two digestive enzymes, lingual lipase and amylase. In this investigation, circadian rhythm in feeding was established under a normal 12 h light/12 h dark cycle, with the rats eating primarily during the dark period. At lights on, the size of the acinar cells and the area of the inclusive secretory granules, and the amount of digestive enzyme activity (lingual lipase and amylase) remaining in the gland was significantly less than in the mid-afternoon, after very little daylight food consumption. However, after 7 days of continuous light the circadian rhythm was altered: the food consumption during the normal night-time hours (5 p.m. to 8 a.m.) went from 88% of total 24 h food consumption to 45%, and during normal daylight hours (8 a.m. to 5 p.m.) from 12% to 55%. These changes were correlated with histometric findings of a near reversal of the areas of acinar cells and secretory granules of a.m. and p.m. samples under continuous light. Lingual lipase activity in the glands went from 35% under 12 h light to 61% under continuous light in the a.m. and from 65% to 39% in the p.m. Amylase activity also showed nearly a reversal in activity remaining in the gland, from 36% at 12 h light to 58% at 24 h light in the a.m. and 64% to 41% for the p.m. samples. These results indicate that the von Ebner's glands of the rat have a circadian rhythm of secretion and storage of secretory proteins that is subject to light entrainment similar to that seen in other exocrine glands such as the parotid and pancreas.

  6. Global Molecular and Morphological Effects of 24-Hour Chromium(VI)Exposure on Shewanella oneidensis MR-1

    SciTech Connect

    Chourey, Karuna; Thompson, Melissa R; Morrell-Falvey, Jennifer L; Verberkmoes, Nathan C; Brown, Steven D; Shah, Manesh B; Zhou, Jizhong; Doktycz, Mitchel John; Hettich, Robert {Bob} L; Thompson, Dorothea K

    2006-01-01

    The biological impact of 24-h ("chronic") chromium(VI) [Cr(VI) or chromate] exposure on ShewanellaoneidensisMR-1 was assessed by analyzing cellular morphology as well as genome-wide differential gene and protein expression profiles. Cells challenged aerobically with an initial chromate concentration of 0.3 mM in complex growth medium were compared to untreated control cells grown in the absence of chromate. At the 24-h time point at which cells were harvested for transcriptome and proteome analyses, no residual Cr(VI) was detected in the culture supernatant, thus suggesting the complete uptake and/or reduction of this metal by cells. In contrast to the untreated control cells, Cr(VI)-exposed cells formed apparently aseptate, nonmotile filaments that tended to aggregate. Transcriptome profiling and mass spectrometry-based proteomic charac terization revealed that the principal molecular response to 24-h Cr(VI) exposure was the induction of prophage-related genes and their encoded products as well as a number of functionally undefined hypothetical genes that were located within the integrated phage regions of the MR-1 genome. In addition, genes with annotated functions in DNA metabolism, cell division, biosynthesis and degradation of the murein (pepti doglycan) sacculus, membrane response, and general environmental stress protection were upregulated, while genes encoding chemotaxis, motility, and transport/binding proteins were largely repressed under conditions of 24-h chromate treatment.

  7. Comparison of the Kid's Block Food Frequency Questionnaire to the 24-hour recall in urban Native American youth.

    PubMed

    Smith, Chery; Fila, Stefanie

    2006-01-01

    This study evaluated the appropriateness of the Kid's Block Food Frequency Questionnaire (Kid's Block FFQ) for use in a group of urban Native American youth by comparing it to a self-reported 24-hr recall. Subjects were 61 urban Native American youth, aged 9-13 years. Researchers assessed dietary intake using the two methods in random order on the same day. Analyses of diets revealed no significant difference between estimated total energy, protein, fat, and saturated fat between the two methods. Significant differences in estimations for the two tools occurred for carbohydrates and some micronutrients. Results suggest that the Kid's Block FFQ may be less appropriate than 24-hr recall in measuring the dietary intake of Native American youth. A high prevalence of obesity in this population necessitates more accurate dietary assessment tools for this population. PMID:16917884

  8. Diurnal 24-hour rhythm in ambulatory heart rate variability during the day shift in rotating shift workers.

    PubMed

    Yoshizaki, Takahiro; Kawano, Yukari; Tada, Yuki; Hida, Azumi; Midorikawa, Toru; Hasegawa, Kohe; Mitani, Takeshi; Komatsu, Taiki; Togo, Fumiharu

    2013-06-01

    Circadian variation in cardiac autonomic nervous system activity and behavior during the day shifts of shift workers has not hitherto been clarified. This study examined diurnal 24-h variation in heart rate variability (HRV), sleep-wake cycle, physical activity, and food intake during the day shift in rotating shift workers. The subjects were female nurses and caregivers working at a health care facility (14 day workers and 13 rotating shift workers). Each subject was asked to undergo 24-h electrocardiograph and step count recordings. Coarse graining spectral analysis was used for approximately 10-min segments of HRV (600 beats) to derive the total power (TOT: >0.04 Hz), integrated power in the low-frequency (LF: 0.04-0.15 Hz) and high-frequency (HF: >0.15 Hz) ranges, the ratio of HF power to TOT (HF nu), and the ratio of LF power to HF power (LF/HF). Double cosinor analysis was used to obtain 24-h and 12-h period variations in variables of HRV and physical activity. While no difference was found in the acrophases of either period for step counts or in the 12-h period of HRV variables between the groups, the acrophases of the 24-h period for HRV variables were delayed by 1.3 to 5.5 h in rotating shift workers, and their differences in HF power, HF nu, and LF/HF reached a significant level (p < 0.05). On the days of the experiment, retiring time, waking up time, total time in bed, sleep efficiency, and mealtimes and energy intake for each diet did not differ between the groups. These results suggest that there is a possibility of an abnormal phase angle between circadian variation in cardiac autonomic nervous system activity and the sleep-wake cycle during the day shift in shift workers.

  9. Successful Non-Surgical Deep Uterine Transfer of Porcine Morulae after 24 Hour Culture in a Chemically Defined Medium

    PubMed Central

    Martinez, Emilio A.; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25°C and 37°C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5°C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25°C but not at 37°C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37°C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37°C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0±0.6 and 9.4±0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs. PMID:25118944

  10. Recurrent Bleeding Within 24 Hours After Uterine Artery Embolization for Severe Postpartum Hemorrhage: Are There Predictive Factors?

    SciTech Connect

    Bros, Sebastien Chabrot, Pascal Kastler, Adrian; Ouchchane, Lemlih; Cassagnes, Lucie; Gallot, Denis; Boyer, Louis

    2012-06-15

    Purpose: To retrospectively identify predictive factors of recurrent bleeding within 24 h after uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: A total of 194 patients underwent UAE for PPH between August 1999 and April 2009 at our institution. Twelve patients experienced recurrent bleeding within the next 24 h; a second attempt at UAE was thus necessary, which was successful in 10 cases. In two cases, hemostatic hysterectomy was performed. Epidemiological, gynecological-obstetrical, anatomic, and biological data were analyzed. Results: Complete data were available for 148 of the 194 (76%) included patients. Sixty-four (43%) were primiparous, 18 (12.2%) had a placenta accreta, 21 (14%) had a coagulopathy, and 28 (18.9%) had an anatomic variant of the uterine arterial vasculature. Mean age and pregnancy term were similar in both recurring and nonrecurrent bleeding groups. After multivariate analysis, three criteria emerged as risk factors of recurrent bleeding: primiparity (10 patients, 83%; odds ratio [OR] = 18.84; P = 0.014), coagulation disorders (6 patients, 50%; OR = 12.08; P = 0.006), and anatomic variant of the uterine arterial vasculature (28 patients; OR = 9.83; P = 0.003). Conclusions: earch for uterine collaterals must be performed before UAE for PPH. Primiparity and coagulation disorders increase the risk of recurrent bleeding after UAE for PPH.

  11. Modeling the toxicokinetics of 24-hour toluene exposure in rats, impact of activity patterns and enzyme induction

    EPA Science Inventory

    Toluene, a solvent used in numerous consumer and industrial applications, exerts its critical effects on the brain and nervous system following inhalation exposure. Our previously published PBPK model successfully predicted toluene concentrations in blood and brain over a range o...

  12. Spinal cord fusion with PEG-GNRs (TexasPEG): Neurophysiological recovery in 24 hours in rats

    PubMed Central

    Kim, C-Yoon; Sikkema, William K. A.; Hwang, In-Kyu; Oh, Hanseul; Kim, Un Jeng; Lee, Bae Hwan; Tour, James M.

    2016-01-01

    Background: The GEMINI spinal cord fusion protocol has been developed to achieve a successful cephalosomatic anastomosis. Here, for the first time, we report the effects of locally applied water-soluble, conductive PEG(polyethylene glycol)ylated graphene nanoribbons (PEG-GNRs) on neurophysiologic conduction after sharp cervical cord transection in rats. PEG-GNRs were produced by the polymerization of ethylene oxide from anion-edged graphene nanoribbons. These combine the fusogenic potential of PEG with the electrical conducting properties of the graphene nanoribbons. Methods: Laminectomy and transection of cervical spinal cord (C5) was performed on Female Sprague-Dawley (SD) rats. After applying PEG-GNR on the severed part, electrophysiological recovery of the reconstructed cervical spinal cord was confirmed by somatosensory evoked potentials (SSEPs) at 24 h after surgery. Results: While no SSEPs were detected in the control group, PEG-GNR treated group showed fast recovery of SSEPs at 24 h after the surgery. Conclusion: In this preliminary dataset, for the first time, we report the effect of a novel form of PEG with the goal of rapid reconstruction of a sharply severed spinal cord.

  13. POTENTIATION OF PULMONARY REFLEX RESPONSE TO CAPSAICIN 24 HOURS FOLLOWING WHOLE-BODY ACROLEIN EXPOSURE IS MEDIATED BY TRPV1

    EPA Science Inventory

    Pulmonary C-fibers are stimulated by irritant air pollutants producing apnea, bronchospasm, and decrease in HR. C-fiber chemoreflex activation is mediated by TRPV1 and release of substance P. While acrolein has been shown to stimulate C-fibers, the persistence of acrolein effect...

  14. The development of a multiorgan ex vivo perfused model: results with the porcine liver-kidney circuit over 24 hours.

    PubMed

    Chung, Wen Yuan; Gravante, Gianpiero; Al-Leswas, Dhya; Arshad, Ali; Sorge, Roberto; Watson, Chris C; Pollard, Cristina; Metcalfe, Matthew S; Dennison, Ashley R

    2013-05-01

    We already developed an ex vivo liver-kidney model perfused for 6 h in which the kidney acted as a homeostatic organ to improve the circuit milieu compared to liver alone. In the current study, we extended the multiorgan perfusions to 24 h to evaluate the results and eventual pitfalls manifesting with longer durations. Five livers and kidneys were harvested from female pigs and perfused over 24 h. The extracorporeal circuit included a centrifugal pump, heat exchanger, and oxygenator. The primary end point of the study was the evaluation of the organ functions as gathered from biochemical and acid-base parameters. In the combined liver-kidney circuit, the organs survived and maintained an acceptable homeostasis for different lengths of time, longer for the liver (up to 19-23 h of perfusions) than the kidney (9-13 h of perfusions). Furthermore, glucose and creatinine values decreased significantly over time (from the 5th and 9th hour of perfusion onward). The addition of a kidney to the perfusion circuit improved the biochemical environment by removing excess products from ongoing metabolic processes. The consequence is a more physiological milieu that could improve results from future experimental studies. However, it is likely that long perfusions require some nutritional support over the hours to maintain the organ's vitality and functionality throughout the experiments. PMID:23489088

  15. Fourth-Grade Children are Less Accurate in Reporting School Breakfast than School Lunch during 24-Hour Dietary Recalls

    PubMed Central

    Baxter, Suzanne Domel; Royer, Julie A.; Hardin, James W.; Guinn, Caroline H.; Smith, Albert F.

    2008-01-01

    Objective To compare reporting accuracy for breakfast and lunch in two studies. Design Children were observed eating school meals and interviewed the following morning about the previous day. Study 1 – 104 children were each interviewed one to three times with ≥25 days separating any two interviews. Study 2 – 121 children were each interviewed once in forward (morning-to-evening) and once in reverse (evening-to-morning) order, separated by ≥29 days. Setting 12 schools. Participants Fourth-grade children. Main Outcome Measures For each meal: food-item variables – observed number, reported number, omission rate, intrusion rate, total inaccuracy; kilocalorie variables – observed, reported, correspondence rate, inflation ratio. Analysis General linear mixed-models. Results For each study, observed and reported numbers of items and kilocalories, and correspondence rate (reporting accuracy), were greater for lunch than breakfast; omission rate, intrusion rate, and inflation ratio (measures of reporting error) were greater for breakfast than lunch. Study 1 – for each meal over interviews, total inaccuracy decreased and correspondence rate increased. Study 2 – for each meal for boys for reverse and girls for forward order, omission rate was lower and correspondence rate was higher. Conclusions and Implications Breakfast was reported less accurately than lunch. Despite improvement over interviews (Study 1) and differences for order × sex (Study 2), reporting accuracy was low for breakfast and lunch. PMID:17493562

  16. Effect of captopril and melatonin on fibrotic rebuilding of the aorta in 24 hour light-induced hypertension.

    PubMed

    Repová-Bednárová, K; Aziriová, S; Hrenák, J; Krajčírovičová, K; Adamcová, M; Paulis, L; Simko, F

    2013-01-01

    Chronic continuous light exposure leads to melatonin deficiency along with complex neurohumoral activation resulting in hypertension development in rats. The aim of this study was to show, whether continuous light induces fibrotic rebuilding of the aorta and whether the treatment with melatonin or angiotensin converting enzyme inhibitor captopril can prevent these potential alterations. In a six-week experiment, 3-month-old Wistar rats were divided into 4 groups (ten per group): controls, rats exposed to continuous light, exposed to continuous light plus treated with captopril (100 mg/kg/24 h) and exposed to continuous light plus treated with melatonin (10 mg/kg/24 h). Systolic blood pressure (SBP) and collagen type I and III in the media of thoracic aorta were measured. Continuous light induced hypertension and fibrotic rebuilding of the aorta in terms of enhancement of collagen I and III concentration in the aortic media. Both captopril and melatonin prevented SBP rise and reduced collagen III concentration in the aorta. However, only melatonin reduced collagen I and the sum of collagen I and III in the aortic tissue. We conclude that in continuous light-induced hypertension, administration of melatonin, along with SBP reduction, decreases collagen I and III concentration in the aorta. It is suggested that antifibrotic effect of melatonin may reduce the stiffness of the aorta and small arteries and beneficially influence the nature of the pulse wave and peripheral vascular resistance.

  17. Effect of metoprolol on 24-hour urinary excretion of adrenal steroids and kallikrein in patients with essential hypertension.

    PubMed Central

    Fritschka, E.; Gotzen, R.; Kittler, R.; Schöneshöfer, M.

    1984-01-01

    Treatment of fifteen patients with essential hypertension over four weeks using the beta 1-adrenoceptor blocking agent, metoprolol, resulted in a decrease in 24 h urinary excretion of kallikrein and aldosterone along with a decrease in plasma renin activity. There was no significant change in 24 h excretion rates of the free adrenal steroids deoxycorticosterone, 18-OH-deoxycorticosterone, corticosterone, cortisol or 18-OH-corticosterone during treatment, which were not significantly different from excretion rates of normal males, thus excluding inhibitory effects of adrenal steroids on urinary kallikrein activity. A positive correlation was found between plasma renin activity and urinary excretion of kallikrein during the control period and after 2 weeks on metoprolol, supporting the assumption of a preserved link between the renin-angiotensin-aldosterone system and the renal excretion of kallikrein in these patients. The decrease in kallikrein excretion during beta 1-adrenoceptor blockade in patients with essential hypertension may be explained by a reduction in sympathetic tone and by reduced activity of the renin-aldosterone system. PMID:6367871

  18. What a Difference a Day Makes: Change in Memory for Newly Learned Word Forms over 24 Hours

    ERIC Educational Resources Information Center

    McGregor, Karla K.

    2014-01-01

    Purpose: This study explored the role of time and retrieval experience in the consolidation of word forms. Method: Participants were 106 adults trained on 16 novel word-referent pairs, then tested immediately and 24 hr later for recognition and recall of word forms. In the interim, tests were repeated 2 hr or 12 hr after training, or not at all,…

  19. A phase I trial of bryostatin 1 in patients with advanced malignancy using a 24 hour intravenous infusion.

    PubMed Central

    Jayson, G. C.; Crowther, D.; Prendiville, J.; McGown, A. T.; Scheid, C.; Stern, P.; Young, R.; Brenchley, P.; Chang, J.; Owens, S.

    1995-01-01

    Bryostatin 1 is a macrocyclic lactone derived from the marine invertebrate Bugula neritina. In vitro, bryostatin 1 activates protein kinase C (PKC), induces the differentiation of a number of cancer cell lineages, exhibits anti-tumour activity and augments the response of haemopoietic cells to certain growth factors. In vivo, bryostatin 1 is also immunomodulatory, but the range of tumours which respond to bryostatin 1 in xenograft tumour models is mostly the same as the in vitro tumour types, suggesting a direct mode of action. Nineteen patients with advanced malignancy were entered into a phase I study in which bryostatin 1 was given as a 24 h intravenous infusion, weekly, for 8 weeks. Myalgia was the dose-limiting toxicity and the maximum tolerated dose was 25 micrograms m-2 per week. The myalgia was cumulative and dose related, and chiefly affected the thighs, calves and muscles of extraocular movement. The mechanism of the myalgia is unknown. CTC grade 1 phlebitis affected every patient for at least one cycle and was caused by the diluent, PET, which contains polyethylene glycol, ethanol and Tween 80. Most patients experienced a 1 g dl-1 decrease in haemoglobin within 1 h of commencing the infusion which was associated with a decrease in haematocrit. Radiolabelled red cell studies were performed in one patient to investigate the anaemia. The survival of radiolabelled red cells during the week following treatment was the same as that seen in the week before treatment. However, there was a temporary accumulation of radiolabelled red cells in the liver during the first hour of treatment, suggesting that pooling of erythrocytes in the liver might account for the decrease in haematocrit. Total or activated PKC concentrations were measured in the peripheral blood mononuclear cells (PBMCs) of three patients for the first 4 h of treatment and during the last hour of the infusion. This showed that PKC activity was significantly modulated during the infusion. Bryostatin 1 is immunomodulatory in vitro, and we have confirmed this activity in vivo. An investigation of the first three cycles of treatment in seven patients showed an increased IL-2-induced proliferative response in peripheral blood lymphocytes and enhanced lymphokine-activated killer (LAK) activity. A previously reported rise in serum levels of interleukin 6 (IL-6) and tumour necrosis factor alpha (TNF 1) was not confirmed in our study; of nine patients in this study, including patients at all dose levels, none showed an increase in these cytokines.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:7640233

  20. Chemically modified tetracycline (COL-3) improves survival if given 12 but not 24 hours after cecal ligation and puncture.

    PubMed

    Halter, Jeffrey M; Pavone, Lucio A; Steinberg, Jay M; Gatto, Louis A; DiRocco, Joseph; Landas, Steve; Nieman, Gary F

    2006-12-01

    Sepsis can result in excessive and maladaptive inflammation that is responsible for more than 215,00 deaths per year in the United State alone. Current strategies for reducing the morbidity and mortality associated with sepsis rely on treatment of the syndrome rather than prophylaxis. We have been investigating a modified tetracycline, COL-3, which can be given prophylactically to patients at high risk for developing sepsis. Our group has shown that COL-3 is very effect at preventing the sequelae of sepsis if given before or immediately after injury in both rat and porcine sepsis models. In this study, we wanted to determine the "treatment window" for COL-3 after injury at which it remains protective. Sepsis was induced by cecal ligation and puncture (CLP). Rats were anesthetized and placed into five groups: CLP (n = 20) = CLP without COL-3, sham (n = 5) = surgery without CLP or COL-3, COL3@6h (n = 10) = COL-3 given by gavage 6 h after CLP, COL3@12h (n = 10) = COL-3 given by gavage 12 h after CLP, and COL3@24h (n = 20) = COL-3 given by gavage 24 h after CLP. COL-3 that was given at 6 and 12 h after CLP significantly improved survival as compared with the CLP and the CLP@24h groups. Improved survival was associated with a significant improvement in lung pathology assessed morphologically. These data suggest that COL-3 can be given up to 12 h after trauma and remain effective.

  1. Delayed-Onset Left Main Coronary Artery Obstruction More than 24 Hours after Balloon-Expandable Transcatheter Aortic Valve Replacement

    PubMed Central

    Tada, Norio; Ootomo, Tatsushi

    2016-01-01

    Coronary obstruction during or after transcatheter aortic valve replacement is a rare and catastrophic sequela that occurs most frequently just after valve implantation. Even rarer is the delayed clinical presentation, in some few patients, of coronary obstruction on the day after self-expandable valve implantation. Here we describe a case of balloon-expandable (not self-expandable) transcatheter aortic valve replacement, followed by partial obstruction of the left main coronary artery on the day after that procedure in a 93-year-old man, despite normal left ventricular contraction just after valve implantation. Visual evaluation of the echocardiogram for left ventricular wall motion was not sufficient, by itself, to achieve early diagnosis of the obstruction. We performed emergency percutaneous coronary intervention. Ninety days after the procedure, the patient was in New York Heart Association functional class I. PMID:27777533

  2. Successful non-surgical deep uterine transfer of porcine morulae after 24 hour culture in a chemically defined medium.

    PubMed

    Martinez, Emilio A; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25 °C and 37 °C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5 °C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25 °C but not at 37 °C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37 °C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37 °C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0 ± 0.6 and 9.4 ± 0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs.

  3. Pain Levels Within 24 Hours After UFE: A Comparison of Morphine and Fentanyl Patient-Controlled Analgesia

    SciTech Connect

    Kim, Hyun S. Czuczman, Gregory J.; Nicholson, Wanda K.; Pham, Luu D.; Richman, Jeffrey M.

    2008-11-15

    The purpose of this study was to assess the presence and severity of pain levels during 24 h after uterine fibroid embolization (UFE) for symptomatic leiomyomata and compare the effectiveness and adverse effects of morphine patient-controlled analgesia (PCA) versus fentanyl PCA. We carried out a prospective, nonrandomized study of 200 consecutive women who received UFE and morphine or fentanyl PCA after UFE. Pain perception levels were obtained on a 0-10 scale for the 24-h period after UFE. Linear regression methods were used to determine pain trends and differences in pain trends between two groups and the association between pain scores and patient covariates. One hundred eighty-five patients (92.5%) reported greater-than-baseline pain after UFE, and 198 patients (99%) required IV opioid PCA. One hundred thirty-six patients (68.0%) developed nausea during the 24-h period. Seventy-two patients (36%) received morphine PCA and 128 (64%) received fentanyl PCA, without demographic differences. The mean dose of morphine used was 33.8 {+-} 26.7 mg, while the mean dose of fentanyl was 698.7 {+-} 537.4 {mu}g. Using this regimen, patients who received morphine PCA had significantly lower pain levels than those who received fentanyl PCA (p < 0.0001). We conclude that patients develop pain requiring IV opioid PCA within 24 h after UFE. Morphine PCA is more effective in reducing post-uterine artery embolization pain than fentanyl PCA. Nausea is a significant adverse effect from opioid PCA.

  4. Dipper and non-dipper blood pressure 24-hour patterns: circadian rhythm-dependent physiologic and pathophysiologic mechanisms.

    PubMed

    Fabbian, Fabio; Smolensky, Michael H; Tiseo, Ruana; Pala, Marco; Manfredini, Roberto; Portaluppi, Francesco

    2013-03-01

    Neuroendocrine mechanisms are major determinants of the normal 24-h blood pressure (BP) pattern. At the central level, integration of the major driving factors of this temporal variability is mediated by circadian rhythms of monoaminergic systems in conjunction with those of the hypothalamic-pituitary-adrenal, hypothalamic-pituitary-thyroid, opioid, renin-angiotensin-aldosterone, plus endothelial systems and specific vasoactive peptides. Humoral secretions are typically episodic, coupled either to sleep and/or the circadian endogenous (suprachiasmatic nucleus) central pacemaker clock, but exhibiting also weekly, monthly, seasonal, and annual periodicities. Sleep induction and arousal are influenced also by many hormones and chemical substances that exhibit 24-h variation, e.g., arginine vasopressin, vasoactive intestinal peptide, melatonin, somatotropin, insulin, steroids, serotonin, corticotropin-releasing factor, adrenocorticotropic hormone, thyrotropin-releasing hormone, endogenous opioids, and prostaglandin E2, all with established effects on the cardiovascular system. As a consequence, physical, mental, and pathologic stimuli that activate or inhibit neuroendocrine effectors of biological rhythmicity may also interfere with, or modify, the temporal BP structure. Moreover, immediate adjustment to exogenous components/environment demands by BP rhythms is modulated by the circadian-time-dependent responsiveness of biological oscillators and their neuroendocrine effectors. This knowledge contributes to a better understanding of the pathophysiology of abnormalities of the 24-h BP pattern and level and their correction through circadian rhythm-based chronotherapeutic strategies. PMID:23002916

  5. Association between 24-Hour Urinary Cadmium and Pulmonary Function among Community-Exposed Men: The VA Normative Aging Study

    PubMed Central

    Lampe, Brad J.; Park, Sung Kyun; Robins, Thomas; Mukherjee, Bhramar; Litonjua, Augusto A.; Amarasiriwardena, Chitra; Weisskopf, Marc; Sparrow, David; Hu, Howard

    2008-01-01

    Background High levels of cadmium exposure are known to cause emphysema in occupationally exposed workers, but little has been reported to date on the association between chronic environmental cadmium exposure and pulmonary function. Objective In this study we examined the association between pulmonary function and cadmium body burden in a subcohort of the Normative Aging Study, a community-based study of aging. Methods We examined 96 men who had cadmium measured in single 24-hr urinary specimens collected in 1994–1995 and who had one to three tests of pulmonary function between 1994 and 2002 (a total of 222 observations). We used mixed-effect models to predict pulmonary function based on individual 24-hr urinary cadmium output, adjusted for age, height, time elapsed from the baseline, and smoking status. We assessed effect modification by smoking status. Results Among all subjects, a single log-unit increase in baseline urinary cadmium was inversely associated with forced expiratory volume in 1 sec (FEV1) percent predicted [β = −7.56%; 95% confidence interval (CI) −13.59% to −1.53%]; forced vital capacity (FVC) percent predicted (β = −2.70%; 95% CI −7.39% to 1.99%), and FEV1/FVC ratio (β = −4.13%; 95% CI −7.61% to −0.66%). In models including an interaction between urinary cadmium and smoking status, there was a graded, statistically significant reduction in FEV1/FVC ratio across smoking status in association with urinary cadmium. Conclusions This study suggests that chronic cadmium exposure is associated with reduced pulmonary function, and cigarette smoking modifies this association. These results should be interpreted with caution because the sample size is small, and further studies are needed to confirm our findings. PMID:18795167

  6. Estimated amount of 24-hour urine sodium excretion is positively correlated with stomach and breast cancer prevalence in Korea.

    PubMed

    Park, Jung Hwan; Kim, Yong Chul; Koo, Ho Seok; Oh, Se Won; Kim, Suhnggwon; Chin, Ho Jun

    2014-09-01

    Stomach cancer is one of the most common cancers in Korea. The aim of this study was to identify the association between the prevalence of cancer, particularly stomach cancer, and the amount of 24-hr urine sodium excretion estimated from spot urine specimens. The study included 19,083 subjects who took part in the Korean National Health and Nutritional Examination Survey between 2009 and 2011. The total amount of urine sodium excreted in a 24-hr period was estimated by using two equations based on the values for spot urine sodium and creatinine. In subjects who had an estimated 24-hr urine sodium excretion of more than two standard deviations above the mean (group 2), the prevalence of stomach cancer was higher than in subjects with lower 24-hr sodium excretion (group 1). By using the Tanaka equation to estimate it, the prevalence of stomach cancer was 0.6% (114/18,331) in group 1, whereas it was 1.6% (9/568) in group 2 (P=0.006). By using the Korean equation, the prevalence was 0.6% (115/18,392) in group 1, and 1.6% in group 2 (8/507) (P=0.010). By using the Tanaka equation, breast cancer in women is more prevalent in group 2 (1.9%, 6/324) than group 1 (0.8%, 78/9,985, P=0.039). Higher salt intake, as defined by the estimated amount of 24-hr urine sodium excretion, is positively correlated with a higher prevalence of stomach or breast cancer in the Korean population.

  7. What Do I Do With Him 24 Hours a Day? Changes in the Housewife Role After Retirement.

    ERIC Educational Resources Information Center

    Keating, Norah C.; Cole, Priscilla

    Retirement is a life cycle phase most couples can now expect to experience. Research on retirement has been directed primarily toward the impact of retirement on the retiree, rather than on the marital dyad. Qualitative and quantitative changes that women experience were investigated, with regards to their role as wife in response to their…

  8. Elimination of Asian fish tapeworms from grass carp with praziquantel bath treatments: The need for 24 hour exposures

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Several states require that imported fish be free of the Asian fish tapeworm Bothriocephalus acheilognathi. Praziquantel has been used for several years to treat fish with Asian fish tapeworms but rates and exposure periods necessary to eliminate these tapeworms from infected fish have not been ade...

  9. Relationships between intact parathyroid hormone 24-hour profiles, sleep-wake cycle, and sleep electroencephalographic activity in man.

    PubMed

    Chapotot, F; Gronfier, C; Spiegel, K; Luthringer, R; Brandenberger, G

    1996-10-01

    To determine whether the 24-h intact PTH (iPTH) profile is influenced by the sleep-wake cycle, and whether iPTH pulses show a temporal relationship with internal sleep structure, eight normal young men were studied during 24 h under basal conditions, once with normal nighttime sleep from 2300-0700 h and once after a night of sleep deprivation followed by an 8-h period of daytime sleep from 0700-1500 h. During the 8-h nighttime sleep period, mean iPTH levels were significantly increased by +13% and mean iPTH pulse amplitudes by +31% as compared with the 8-h subsequent waking periods. During the 8 h of total sleep deprivation, mean iPTH levels were not significantly different from the corresponding period in nighttime sleep condition, but mean iPTH pulse amplitudes were significantly lower (P < 0.01). The 8-h daytime sleep period was associated with increased mean iPTH levels and mean iPTH pulse amplitudes (+15% and +57%, respectively, as compared with the corresponding period in nighttime sleep condition). The number of pulses was similar in both experimental series and was not influenced by sleep or by time of day. Analysis of coincidence between iPTH pulses, plasma ionized calcium and plasma phosphate pulses, and slow wave sleep, as well as with rapid eye movement sleep episodes, did not reveal any significant association. Cross-correlation analysis between iPTH, plasma ionized calcium, and plasma phosphate fluctuations during sleep also showed no systematic association. Seven other subjects were studied during a nighttime sleep period in which temporal relationships between iPTH and internal sleep structure were reevaluated using spectral analysis of the sleep electroencephalogram. Cross-correlation analysis between iPTH levels and delta-relative power fluctuations showed nonsignificant results, which confirms the lack of relationship with slow wave sleep. This study demonstrates that the iPTH 24-h profile is influenced by sleep processes with a weak circadian component. However, iPTH pulses are not temporally linked with sleep electroencephalographic activity nor with calcemia and phosphatemia fluctuations. This evidence raises questions about the origin of iPTH pulses.

  10. What a Difference a Day Makes: Change in Memory for Newly Learned Word Forms Over 24 Hours

    PubMed Central

    McGregor, Karla K.

    2014-01-01

    Purpose This study explored the role of time and retrieval experience in the consolidation of word forms. Method Participants were 106 adults trained on 16 novel word-referent pairs, then tested immediately and 24 hr later for recognition and recall of word forms. In the interim, tests were repeated 2 hr or 12 hr after training, or not at all, thus varying the amount and timing of retrieval experience. Results Recognition accuracy was stable and speed improved over the 24-hr period. But these manifestations of consolidation did not depend on interim retrieval experience; in fact, the 2-hr interim test interfered with improvements in speed. In contrast, the number of word forms recalled increased only with interim retrieval experiences, and the 12-hr interim test was more advantageous to recall than the 2-hr test. Conclusions After a word form is encoded, it can become stronger with time. Retrieval experience can also strengthen the trace, but, if retrieval occurs when the memory is still labile, it can be disruptive. This complex interplay between retrieval experience and time holds implications for measuring learning outcomes and for scheduling practice in classrooms and clinics. PMID:24845578

  11. Validation of the Portuguese self-administered computerised 24-hour dietary recall among second-, third- and fourth-grade children

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Current methods for assessing children's dietary intake, such as interviewer-administered 24-h dietary recall (24-h DR), are time consuming and resource intensive. Self-administered instruments offer a low-cost diet assessment method for use with children. The present study assessed the validity of ...

  12. DASH for Health: Validation of Web-based 24-Hour Recall Questionnaire Designed for a Lifestyle Modification Program

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The DASH eating plan is nationally recognized and recommended by the 2005 Dietary Guidelines for Americans, among others, as a healthful way to reduce hypertension and hypercholesterolemia, and as being an overall healthy diet for all Americans. We created a web-based nutrition and physical activity...

  13. Thyroid uptake and imaging with iodine-123 at 4-5 hours: replacement of the 24-hour iodine-131 standard

    SciTech Connect

    Floyd, J.L.; Rosen, P.R.; Borchert, R.D.; Jackson, D.E.; Weiland, F.L.

    1985-08-01

    A study was carried out to determine the suitability of utilizing a 4 to 5 hr interval from administration of Iodine-123 to imaging and uptake measurement as a replacement for the 24-hr standard originally established with Iodine-131. In 55 patients who underwent scintigraphy at 4 and 24 hr, there was no discrepancy between paired images. In 55 patients who had uptake measured at 4 and 24 hr and in 191 patients who had uptake measured at 5 and 24 hr, the early measurements proved equal or better discriminants of euthyroid from hyperthyroid patients. In our institutions, these findings and the logistical advantages of completing the exam in 4-5 hr led us to abandon the 24-hr study in the majority of patients.

  14. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    SciTech Connect

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4].

  15. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    DOE PAGES

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analyticalmore » methods employed and is related to [4].« less

  16. MONITORING DESIGN

    EPA Science Inventory

    The monitoring design component of the overall Monitoring Framework provides answers to the questions: What site or environment will be monitored? What parameters will be measured at the site? Where will the measurements be taken? When and how frequently will the measurements be ...

  17. High-resolution renal perfusion mapping using contrast-enhanced ultrasonography in ischemia-reperfusion injury monitors changes in renal microperfusion.

    PubMed

    Fischer, Krisztina; Meral, F Can; Zhang, Yongzhi; Vangel, Mark G; Jolesz, Ferenc A; Ichimura, Takaharu; Bonventre, Joseph V

    2016-06-01

    Alterations in renal microperfusion play an important role in the development of acute kidney injury with long-term consequences. Here we used contrast-enhanced ultrasonography as a novel method for depicting intrarenal distribution of blood flow. After infusion of microbubble contrast agent, bubbles were collapsed in the kidney and postbubble destruction refilling was measured in various regions of the kidney. Local perfusion was monitored in vivo at 15, 30, 45, 60 minutes and 24 hours after 28 minutes of bilateral ischemia in 12 mice. High-resolution, pixel-by-pixel analysis was performed on each imaging clip using customized software, yielding parametric perfusion maps of the kidney, representing relative blood volume in each pixel. These perfusion maps revealed that outer medullary perfusion decreased disproportionately to the reduction in the cortical and inner medullary perfusion after ischemia. Outer medullary perfusion was significantly decreased by 69% at 60 minutes postischemia and remained significantly less (40%) than preischemic levels at 24 hours postischemia. Thus, contrast-enhanced ultrasonography with high-resolution parametric perfusion maps can monitor changes in renal microvascular perfusion in space and time in mice. This novel technique can be translated to clinical use in man. PMID:27165821

  18. Authenticated tracking and monitoring system (ATMS) tracking shipments from an Australian uranium mine

    SciTech Connect

    Schoeneman, J.L.

    1998-08-01

    The Authenticated Tracking and Monitoring System (ATMS) answers the need for global monitoring of the status and location of sensitive items on a worldwide basis, 24 hours a day. ATMS uses wireless sensor packs to monitor the status of the items and environmental conditions. A receiver and processing unit collect a variety of sensor event data. The collected data are transmitted to the INMARSAT satellite communication system, which then sends the data to appropriate ground stations. Authentication and encryption algorithms secure the data during communication activities. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements. Following discussions between the Australian Safeguards Office (ASO), the US Department of Energy (DOE), and Sandia National Laboratories (SNL) in early 1995, the parties mutually agreed to conduct and evaluate a field trial prototype ATMS to track and monitor shipments of uranium ore concentrate (UOC) from an operating uranium mine in Australia to a final destination in Rotterdam, the Netherlands, with numerous stops along the way. During the months of February and March 1998, the trial was conducted on a worldwide basis, with tracking and monitoring stations located at sites in both Australia and the US. This paper describes ATMS and the trial.

  19. Air monitoring of aromatic hydrocarbons during automobile spray painting for developing change schedule of respirator cartridges

    PubMed Central

    2014-01-01

    In the absence of End of Service Life Indicator (ESLI), a cartridge change schedule should be established for ensuring that cartridges are changed before their end of service life. Factors effecting service life of cartridges were evaluated, including the amount of atmospheric contamination with aromatic hydrocarbon vapors in the workplace, temperature, and relative humidity of the air. A new change schedule was established based on comparing the results of air monitoring and workplace conditions, laboratory experiment, and the NIOSH MultiVapor software. Spray painters were being exposed to aromatic hydrocarbons in a range exceeding occupational exposure limits. The cartridge change schedule was not effective and could no longer provide adequate protection against organic contaminants for sprayers. Change schedules for respirator cartridges should be reduced from 16–24 hours to 4 hours. NIOSH’s service life software program could be applied to developing cartridge change schedules. PMID:24468234

  20. Multi-parameter monitoring of a solution mining cavern collapse: First insight of precursors

    NASA Astrophysics Data System (ADS)

    Contrucci, Isabelle; Klein, Emmanuelle; Cao, Ngoc-Tuyen; Daupley, Xavier; Bigarré, Pascal

    2011-01-01

    In order to improve our understanding of the large-scale ground failure phenomena caused by old underground mining works, a solution mine was instrumented in 2004 prior to its collapse as part of the mining scheme. A permanent monitoring system was set up, including a high-resolution microseismic network linked to a surface field-displacement measurement system. The large amount of data transmitted for on-line processing provided daily insight into the evolution of the geological system. First, microseismic activity showed upward progressive failure migration throughout 2008 without any significant surface movement. Second, after two days of intensive brine extraction, a high microseismicity and energy release rate marked the failure of a thin and very rigid bed at a depth of 120 m. This failure occurred 24 hours before the final collapse; it was followed by transient brine pressure signals, and by acceleration of the surface subsidence rate, reaching 1 m/h in the final phase.

  1. Motion-based wake-up scheme for ambulatory monitoring in wireless body sensor networks.

    PubMed

    Pek, Isaac; Waluyo, Agustinus Borgy; Yeoh, Wee-Soon; Chen, Xiang

    2009-01-01

    Given that wearable sensors that are attached on patients for the purpose of continuous real-time medical monitoring typically need to remain operational for periods of up to 24 hours before a battery change or recharge, power preservation schemes play a critical role in minimizing any possible disruption to a patient's daily activities. In this paper, we propose a motion-based wake-up scheme, a feature which combines motion detection with existing power preservation schemes in order to achieve a balance between energy saving and data timeliness, particularly in critical situations. As a showcase, we have integrated this feature with a healthcare application and demonstrate the capability of the scheme to deal with critical events, e.g., when a patient falls down from the bed. This showcase affirms the effective uses of our proposed motion-based wake-up scheme.

  2. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone

    PubMed Central

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-01-01

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user’s physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone. PMID:25996508

  3. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone.

    PubMed

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-05-19

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user's physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone.

  4. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone.

    PubMed

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-01-01

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user's physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone. PMID:25996508

  5. How Often Should We Monitor for Reliable Detection of Atrial Fibrillation Recurrence? Efficiency Considerations and Implications for Study Design

    PubMed Central

    Charitos, Efstratios I.; Ziegler, Paul D.; Stierle, Ulrich; Robinson, Derek R.; Graf, Bernhard; Sievers, Hans-Hinrich; Hanke, Thorsten

    2014-01-01

    Objective Although atrial fibrillation (AF) recurrence is unpredictable in terms of onset and duration, current intermittent rhythm monitoring (IRM) diagnostic modalities are short-termed and discontinuous. The aim of the present study was to investigate the necessary IRM frequency required to reliably detect recurrence of various AF recurrence patterns. Methods The rhythm histories of 647 patients (mean AF burden: 12±22% of monitored time; 687 patient-years) with implantable continuous monitoring devices were reconstructed and analyzed. With the use of computationally intensive simulation, we evaluated the necessary IRM frequency to reliably detect AF recurrence of various AF phenotypes using IRM of various durations. Results The IRM frequency required for reliable AF detection depends on the amount and temporal aggregation of the AF recurrence (p<0.0001) as well as the duration of the IRM (p<0.001). Reliable detection (>95% sensitivity) of AF recurrence required higher IRM frequencies (>12 24-hour; >6 7-day; >4 14-day; >3 30-day IRM per year; p<0.0001) than currently recommended. Lower IRM frequencies will under-detect AF recurrence and introduce significant bias in the evaluation of therapeutic interventions. More frequent but of shorter duration, IRMs (24-hour) are significantly more time effective (sensitivity per monitored time) than a fewer number of longer IRM durations (p<0.0001). Conclusions Reliable AF recurrence detection requires higher IRM frequencies than currently recommended. Current IRM frequency recommendations will fail to diagnose a significant proportion of patients. Shorter duration but more frequent IRM strategies are significantly more efficient than longer IRM durations. Clinical Trial Registration URL Unique identifier: NCT00806689. PMID:24563690

  6. Use of ambulatory blood pressure monitoring to compare antihypertensive efficacy and safety of two angiotensin II receptor antagonists, losartan and valsartan. Losartan Trial Investigators.

    PubMed

    Monterroso, V H; Rodriguez Chavez, V; Carbajal, E T; Vogel, D R; Aroca Martinez, G J; Garcia, L H; Cuevas, J H; Lara Teran, J; Hitzenberger, G; Leao Neves, P; Middlemost, S J; Dumortier, T; Bunt, A M; Smith, R D

    2000-01-01

    The efficacy and safety of losartan and valsartan were evaluated in a multicenter, double-blind, randomized trial in patients with mild to moderate essential hypertension. Blood pressure responses to once-daily treatment with either losartan 50 mg (n = 93) or valsartan 80 mg (n = 94) for 6 weeks were assessed through measurements taken in the clinic and by 24-hour ambulatory blood pressure monitoring (ABPM). Both drugs significantly reduced clinic sitting systolic (SiSBP) and diastolic blood pressure (SiDBP) at 2, 4, and 6 weeks. Maximum reductions from baseline in SiSBP and SiDBP on 24-hour ABPM were also significant with the two treatments. The reduction in blood pressure was more consistent across patients in the losartan group, as indicated by a numerically smaller variability in change from baseline on all ABPM measures, which achieved significance at peak (P = .017) and during the day (P = .002). In addition, the numerically larger smoothness index with losartan suggested a more homogeneous antihypertensive effect throughout the 24-hour dosing interval. The antihypertensive response rate was 54% with losartan and 46% with valsartan. Three days after discontinuation of therapy, SiDBP remained below baseline in 73% of losartan and 63% of valsartan patients. Both agents were generally well tolerated. Losartan, but not valsartan, significantly decreased serum uric acid an average 0.4 mg/dL at week 6. In conclusion, once-daily losartan 50 mg and valsartan 80 mg had similar antihypertensive effects in patients with mild to moderate essential hypertension. Losartan produced a more consistent blood pressure-lowering response and significantly lowered uric acid, suggesting potentially meaningful differences between these two A II receptor antagonists.

  7. Optimising calcium monitoring post thyroid and parathyroid surgery.

    PubMed

    Rayner, Eleanor; Williams, Nerida; Dunn, Julie

    2014-01-01

    There is a risk of hypocalcaemia following total thyroidectomy and parathyroidectomy surgery, with the nadir being two to five days post operatively.[1] This project examined and improved the post-operative monitoring of serum calcium in patients undergoing these procedures at the Royal Devon and Exeter (RD&E) Hospital over a ten month period in 2013. A retrospective audit was undertaken, identifying whether serum calcium was monitored according to guideline; ie measured within the first 24 hours of surgery and daily thereafter until the patient was normocalcaemic.[2-3] The audit showed an overall compliance in 79% (n = 34) of cases. Of the non-compliant cases (n=9), seven also suffered hypocalcaemia. The current process was mapped by a flow chart and used as a basis for discussing experiences and identifying areas for improvement. Interventions implemented included a patient leaflet, a process flow chart displayed in the team office and in the weekend handover book, standard text for use in discharge summaries describing the process to GPs, the issuing of prescriptions or actual supplements for patients felt to be at high risk of hypocalcaemia, and finally education to the wider surgical junior doctor team. Percentage compliance with guidelines was compared before and after intervention with a re-audit undertaken in April 2014. Significant improvement was shown, with 100% of re-audit cases compliant (n=41), and all seven cases of hypocalcaemia were managed in full compliance with guideline. PMID:26732097

  8. Optimising calcium monitoring post thyroid and parathyroid surgery

    PubMed Central

    Rayner, Eleanor; Williams, Nerida; Dunn, Julie

    2014-01-01

    There is a risk of hypocalcaemia following total thyroidectomy and parathyroidectomy surgery, with the nadir being two to five days post operatively.[1] This project examined and improved the post-operative monitoring of serum calcium in patients undergoing these procedures at the Royal Devon and Exeter (RD&E) Hospital over a ten month period in 2013. A retrospective audit was undertaken, identifying whether serum calcium was monitored according to guideline; ie measured within the first 24 hours of surgery and daily thereafter until the patient was normocalcaemic.[2–3] The audit showed an overall compliance in 79% (n = 34) of cases. Of the non-compliant cases (n=9), seven also suffered hypocalcaemia. The current process was mapped by a flow chart and used as a basis for discussing experiences and identifying areas for improvement. Interventions implemented included a patient leaflet, a process flow chart displayed in the team office and in the weekend handover book, standard text for use in discharge summaries describing the process to GPs, the issuing of prescriptions or actual supplements for patients felt to be at high risk of hypocalcaemia, and finally education to the wider surgical junior doctor team. Percentage compliance with guidelines was compared before and after intervention with a re-audit undertaken in April 2014. Significant improvement was shown, with 100% of re-audit cases compliant (n=41), and all seven cases of hypocalcaemia were managed in full compliance with guideline. PMID:26732097

  9. Volcano monitoring using the Global Positioning System: Filtering strategies

    USGS Publications Warehouse

    Larson, K.M.; Cervelli, Peter; Lisowski, M.; Miklius, Asta; Segall, P.; Owen, S.

    2001-01-01

    Permanent Global Positioning System (GPS) networks are routinely used for producing improved orbits and monitoring secular tectonic deformation. For these applications, data are transferred to an analysis center each day and routinely processed in 24-hour segments. To use GPS for monitoring volcanic events, which may last only a few hours, real-time or near real-time data processing and subdaily position estimates are valuable. Strategies have been researched for obtaining station coordinates every 15 min using a Kalman filter; these strategies have been tested on data collected by a GPS network on Kilauea Volcano. Data from this network are tracked continuously, recorded every 30 s, and telemetered hourly to the Hawaiian Volcano Observatory. A white noise model is heavily impacted by data outages and poor satellite geometry, but a properly constrained random walk model fits the data well. Using a borehole tiltmeter at Kilauea's summit as ground-truth, solutions using different random walk constraints were compared. This study indicates that signals on the order of 5 mm/h are resolvable using a random walk standard deviation of 0.45 cm/???h. Values lower than this suppress small signals, and values greater than this have significantly higher noise at periods of 1-6 hours. Copyright 2001 by the American Geophysical Union.

  10. Bladder Monitor

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Diagnostic Ultrasound Corporation's Bladder Scan Monitor continuously records and monitors bladder fullness and alerts the wearer or caretaker when voiding is required. The sensor is held against the lower abdomen by a belt and connected to the monitor by a cable. The sensor obtains bladder volume data from sound waves reflecting off the bladder wall. The device was developed by Langley Research Center, the Ames Research Center and the NASA Technology Applications Team. It utilizes Langley's advanced ultrasound technology. It is licensed to the ARC for medical applications, and sublicensed to Diagnostics Ultrasound. Central monitoring systems are planned for the future.

  11. Monitoring your baby before labor

    MedlinePlus

    Prenatal care - monitoring; Pregnancy care - monitoring; Non-stress test - monitoring; NST- monitoring; Contraction stress test - monitoring; CST- monitoring; Biophysical profile - monitoring; BPP - monitoring

  12. National Approaches to Monitoring Population Salt Intake: A Trade-Off between Accuracy and Practicality?

    PubMed Central

    Hawkes, Corinna; Webster, Jacqui

    2012-01-01

    Aims There is strong evidence that diets high in salt are bad for health and that salt reduction strategies are cost effective. However, whilst it is clear that most people are eating too much salt, obtaining an accurate assessment of population salt intake is not straightforward, particularly in resource poor settings. The objective of this study is to identify what approaches governments are taking to monitoring salt intake, with the ultimate goal of identifying what actions are needed to address challenges to monitoring salt intake, especially in low and middle-income countries. Methods and Results A written survey was issued to governments to establish the details of their monitoring methods. Of the 30 countries that reported conducting formal government salt monitoring activities, 73% were high income countries. Less than half of the 30 countries, used the most accurate assessment of salt through 24 hour urine, and only two of these were developing countries. The remainder mainly relied on estimates through dietary surveys. Conclusions The study identified a strong need to establish more practical ways of assessing salt intake as well as technical support and advice to ensure that low and middle income countries can implement salt monitoring activities effectively. PMID:23082128

  13. Ion Monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2003-11-18

    The apparatus and method provide a technique for significantly reducing capacitance effects in detector electrodes arising due to movement of the instrument relative to the item/location being monitored in ion detection based techniques. The capacitance variations are rendered less significant by placing an electrically conducting element between the detector electrodes and the monitored location/item. Improved sensitivity and reduced noise signals arise as a result. The technique also provides apparatus and method suitable for monitoring elongate items which are unsuited to complete enclosure in one go within a chamber. The items are monitored part by part as the pass through the instrument, so increasing the range of items or locations which can be successfully monitored.

  14. Ambulatory Cardiac Monitoring for Discharged Emergency Department Patients with Possible Cardiac Arrhythmias

    PubMed Central

    Schreiber, Donald; Sattar, Ayesha; Drigalla, Dorian; Higgins, Steven

    2014-01-01

    Introduction Many emergency department (ED) patients have symptoms that may be attributed to arrhythmias, necessitating outpatient ambulatory cardiac monitoring. Consensus is lacking on the optimal duration of monitoring. We describe the use of a novel device applied at ED discharge that provides continuous prolonged cardiac monitoring. Methods We enrolled discharged adult ED patients with symptoms of possible cardiac arrhythmia. A novel, single use continuous recording patch (Zio®Patch) was applied at ED discharge. Patients wore the device for up to 14 days or until they had symptoms to trigger an event. They then returned the device by mail for interpretation. Significant arrhythmias are defined as: ventricular tachycardia (VT) ≥4 beats, supraventricular tachycardia (SVT) ≥4 beats, atrial fibrillation, ≥3 second pause, 2nd degree Mobitz II, 3rd degree AV Block, or symptomatic bradycardia. Results There were 174 patients were enrolled and all mailed back their devices. The average age was 52.2 (± 21.0) years, and 55% were female. The most common indications for device placement were palpitations 44.8%, syncope 24.1% and dizziness 6.3%. Eighty-three patients (47.7%) had ≥1 arrhythmias and 17 (9.8%) were symptomatic at the time of their arrhythmia. Median time to first arrhythmia was 1.0 days (IQR 0.2–2.8) and median time to first symptomatic arrhythmia was 1.5 days (IQR 0.4–6.7). 93 (53.4%) of symptomatic patients did not have any arrhythmia during their triggered events. The overall diagnostic yield was 63.2% Conclusion The Zio®Patch cardiac monitoring device can efficiently characterize symptomatic patients without significant arrhythmia and has a higher diagnostic yield for arrhythmias than traditional 24–48 hour Holter monitoring. It allows for longer term monitoring up to 14 days. PMID:24672611

  15. Electrostatic monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2001-01-01

    The apparatus and method provide a technique for more simply measuring alpha and/or beta emissions arising from items or locations. The technique uses indirect monitoring of the emissions by detecting ions generated by the emissions, the ions being attracted electrostatically to electrodes for discharge of collection. The apparatus and method employ a chamber which is sealed around the item or location during monitoring with no air being drawn into or expelled from the chamber during the monitoring process. A simplified structure and operations arises as a result, but without impairing the efficiency and accuracy of the detection technique.

  16. Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study

    PubMed Central

    2011-01-01

    Background Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting. Methods Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions), we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements. Results The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2). Wearers found the monitor straightforward to use (mean 7.5). Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%), skin irritation (37%), and bruising (7%). Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003) were more likely to report being in fair/poor health (75% vs 22%, p = 0.01) and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37). They were also more likely

  17. Environment Monitor

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Viking landers touched down on Mars equipped with a variety of systems to conduct automated research, each carrying a compact but highly sophisticated instrument for analyzing Martian soil and atmosphere. Instrument called a Gas Chromatography/Mass Spectrometer (GC/MS) had to be small, lightweight, shock resistant, highly automated and extremely sensitive, yet require minimal electrical power. Viking Instruments Corporation commercialized this technology and targeted their primary market as environmental monitoring, especially toxic and hazardous waste site monitoring. Waste sites often contain chemicals in complex mixtures, and the conventional method of site characterization, taking samples on-site and sending them to a laboratory for analysis is time consuming and expensive. Other terrestrial applications are explosive detection in airports, drug detection, industrial air monitoring, medical metabolic monitoring and for military, chemical warfare agents.

  18. Sitcom syncope: a case series and literature review of gelastic (laughter-induced) syncope.

    PubMed

    Thiagarajah, Prashan H; Finkielstein, Dennis; Granato, Jerome E

    2010-11-01

    Syncope is a common complaint that is frequently evaluated without identifying a precipitating cause. Gelastic (laughter-induced) syncope is an uncommon and poorly understood condition. We describe 3 patients who experienced loss of consciousness during vigorous laughter. Each patient had an extensive medical evaluation, including a comprehensive history and physical examination, 12-lead electrocardiography, chest radiograph, routine blood analysis, polysomnography, tilt table testing, 2-dimensional transthoracic echocardiography, nuclear or echocardiographic stress testing, and 24-hour Holter monitoring. All 3 patients had an abnormal response to head-up tilt table testing, with either a significant decrease in systolic blood pressure or inappropriate heart rate response on achieving an upright position. These observations together with our review of the literature suggest that gelastic syncope may be a variant of vasodepressor syncope. Knowledge of this condition, its pathophysiology, and potential treatment options may be of value to clinicians when evaluating patients with unexplained loss of consciousness.

  19. Renal sympathetic denervation as an adjunct to catheter ablation for the treatment of ventricular electrical storm in the setting of acute myocardial infarction.

    PubMed

    Hoffmann, Boris A; Steven, Daniel; Willems, Stephan; Sydow, Karsten

    2013-10-01

    We present a case of ventricular storm (VS) in a patient with acute ST-elevation myocardial infarction (STEMI). After initial successful thrombus extraction and percutaneous coronary intervention (PCI) of the proximal left anterior descending (LAD) coronary artery, a 63-year-old male patient showed recurrent monomorphic ventricular tachycardia (VT) and fibrillation (VF) episodes refractory to antiarrhythmic drug therapy. After initial successful VT ablation, fast VT and VF episodes remained an evident problem despite maximum antiarrhythmic drug therapy. Due to an increasing instability, renal sympathetic denervation (RDN) was performed. ICD interrogation and 24-hour Holter monitoring excluded recurrent episodes of VT or VF at a 6-month follow-up (FU) after discharge. This case highlights that RDN was effective and safely performed in a hemodynamically unstable patient with VS after STEMI and adjunct catheter ablation. RDN may open a new avenue for an adjunctive interventional bailout treatment of such highly challenging patients.

  20. COLD MAGICS - Continuous Local Deformation Monitoring of an Arctic Geodetic Fundamental Station

    NASA Technical Reports Server (NTRS)

    Haas, Ruediger; Bergstrand, Sten

    2010-01-01

    We describe the experience gained in a project to continuously monitor the local tie at the Geodetic Observatory Ny-Alesund. A PC-controlled robotic total station was used to monitor survey prisms that were attached to survey pillars of the local network and the monuments used for geodetic VLBI and GNSS measurements. The monitoring lasted for seven days and had a temporal resolution of six minutes. The raw angle and distance measurements show clear sinusoidal signatures with a daily period, most strongly for a four-day period with 24 hours of sunshine. The derived topocentric coordinates of the survey prisms attached to the GNSS monument and the VLBI radio telescope act as approximation for the local tie. We detect clear signatures at the mm-level. With the current approach we cannot distinguish between real motion of the prisms and potential thermal influences on the instrument used for the observations. However, the project shows that continuous local tie monitoring is feasible today and in the future can and should be used for all geodetic co-location stations.

  1. Dietary assessment and self-monitoring with nutrition applications for mobile devices.

    PubMed

    Lieffers, Jessica R L; Hanning, Rhona M

    2012-01-01

    Nutrition applications for mobile devices (e.g., personal digital assistants, smartphones) are becoming increasingly accessible and can assist with the difficult task of intake recording for dietary assessment and self-monitoring. This review is a compilation and discussion of research on this tool for dietary intake documentation in healthy populations and those trying to lose weight. The purpose is to compare this tool with conventional methods (e.g., 24-hour recall interviews, paper-based food records). Research databases were searched from January 2000 to April 2011, with the following criteria: healthy or weight loss populations, use of a mobile device nutrition application, and inclusion of at least one of three measures, which were the ability to capture dietary intake in comparison with conventional methods, dietary self-monitoring adherence, and changes in anthropometrics and/or dietary intake. Eighteen studies are discussed. Two application categories were identified: those with which users select food and portion size from databases and those with which users photograph their food. Overall, positive feedback was reported with applications. Both application types had moderate to good correlations for assessing energy and nutrient intakes in comparison with conventional methods. For self-monitoring, applications versus conventional techniques (often paper records) frequently resulted in better self-monitoring adherence, and changes in dietary intake and/or anthropometrics. Nutrition applications for mobile devices have an exciting potential for use in dietetic practice. PMID:22958633

  2. Time-series model for predicting ambient TSP concentrations at monitors located near coal-fired power plants

    SciTech Connect

    Warren-Hicks, W.; Siple, G.

    1984-01-01

    The scope of this paper is to develop a time-series model applicable to a number of data sets containing total suspended particulate (TSP) data. The authors wanted the mathematical form of the model to be as simple as possible while maintaining a good fit to all the TSP data sets involved. To this end, data from three TSP monitoring sites, which are located near coal-fired power plants operated by Carolina Power and Light Company in North Carolina, were chosen for analysis. The data consisted of every-sixth-day, 24-hour TSP concentrations collected using a high-volume sampler and measured gravimetrically. An autoregressive integrated moving average (ARIMA) time-series, model was fit to each data set. The model was then used to fill in missing concentrations and forecast future values. Forecasted values were compared against measured maximum and averaged values.

  3. COMPARATIVE EVALUATION OF AMBIENT FINE PARTICULATE MATTER (PM2.5) DATA OBTAINED FROM URBAN AND RURAL MONITORING SITES ALONG THE UPPER OHIO RIVER VALLEY

    SciTech Connect

    Robinson P. Khosah; John P. Shimshock; Jerry L. Penland

    2004-10-15

    Advanced Technology Systems, Inc. (ATS), with Desert Research Institute (DRI) and Ohio University as subcontractors, was contracted by the NETL in September 1998 to manage the Upper Ohio River Valley Project (UORVP), which included the establishment and operation of four ambient air monitoring sites located in the Upper Ohio River Valley (UORV). Two urban and two rural monitoring sites were included in the UORVP. The four sites selected for the UOVRP were collocated at existing local and/or state air quality monitoring stations. The goal of the UORVP was to characterize the nature and composition of PM{sub 2.5} and its precursor gases. In the process, the objectives of the UORVP were to examine the ambient air concentrations of PM{sub 2.5} as compared with the promulgated PM{sub 2.5} standards, the geographical, seasonal and temporal variations of ambient air concentrations of PM{sub 2.5}, the primary chemical constituents of PM{sub 2.5}, and the correlations between ambient air concentrations of PM{sub 2.5} and its precursor gases, other gaseous pollutants and meteorological parameters. A variety of meteorological and pollutant measurement devices, including several different PM{sub 2.5} samplers that provided either real-time or integrated concentration data, were deployed at the monitoring sites. The frequency of integrated sampling varied throughout the UORVP study period and was as follows: ''Intensive'' sampling periods were defined as periods in which samples were collected on a relatively frequent basis (ranged from 6-hour integrated samples collected round-the-clock to one 24-hour integrated sample collected every third day). ''Background'' sampling periods were defined as periods in which 24-hour integrated samples were collected every third or sixth day.

  4. Noninvasive Cardiac Screening in Young Athletes With Ventricular Arrhythmias

    PubMed Central

    Steriotis, Alexandros Klavdios; Nava, Andrea; Rigato, Ilaria; Mazzotti, Elisa; Daliento, Luciano; Thiene, Gaetano; Basso, Cristina; Corrado, Domenico; Bauce, Barbara

    2013-01-01

    The aim of this study was to analyze using noninvasive cardiac examinations a series of young athletes discovered to have ventricular arrhythmias (VAs) during the preparticipation screening program for competitive sports. One hundred forty-five athletes (mean age 17 ± 5 years) were evaluated. The study protocol included electrocardiography (ECG), exercise testing, 2-dimensional and Doppler echocardiography, 24-hour Holter monitoring, signal-averaged ECG, and in selected cases contrast-enhanced cardiac magnetic resonance imaging. Results of ECG were normal in most athletes (85%). VAs were initially detected prevalently during exercise testing (85%) and in the remaining cases on ECG and Holter monitoring. Premature ventricular complexes disappeared during exercise in 56% of subjects. Premature ventricular complexes during Holter monitoring averaged 4,700 per day, predominantly monomorphic (88%), single, and/or in couplets (79%). The most important echocardiographic findings were mitral valve prolapse in 29 patients (20%), congenital heart disease in 4 (3%), and right ventricular regional kinetic abnormalities in 5 (3.5%). On cardiac magnetic resonance imaging, right ventricular regional kinetic abnormalities were detected in 9 of 30 athletes and were diagnostic of arrhythmogenic right ventricular cardiomyopathy in only 1 athlete. Overall, 30% of athletes were judged to have potentially dangerous VAs. In asymptomatic athletes with prevalently normal ECG, most VAs can be identified by adding an exercise test during preparticipation screening. In conclusion, cardiac screening with noninvasive examinations remains a fundamental tool for the identification of a possible pathologic substrate and for the characterization of electrical instability. PMID:23219000

  5. LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

    SciTech Connect

    Forrester, Joel B.; Bowyer, Ted W.; Carty, Fitz; Comes, Laura; Eslinger, Paul W.; Greenwood, Lawrence R.; Haas, Derek A.; Hayes, James C.; Kirkham, Randy R.; Lepel, Elwood A.; Litke, Kevin E.; Miley, Harry S.; Morris, Scott J.; Schrom, Brian T.; Van Davelaar, Peter; Woods, Vincent T.

    2011-09-14

    The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

  6. Noninvasive monitoring of salmonella infections in young mice

    NASA Astrophysics Data System (ADS)

    Olomu, Isoken N.; Reilly-Contag, Pamela; Stevenson, David K.; Contag, Christopher H.

    1999-07-01

    A recently developed bioluminescent assay was used to study the influence of age and inoculum size on the acute susceptibility of newborn and juvenile BALB/c mice to Salmonella gastrointestinal infection. Three strains of Salmonella were tagged by expression of the lux operon from Photohabdus luminescenes. Using a range of inoculum sizes varied over 6 orders of magnitude, mice aged 0-6 weeks were infected by oral inoculation. LIght emitted from the tagged bacteria and transmitted through mouse tissues was used to noninvasively monitor disease progression over 7 days. In neonatal mice there was evidence of gastrointestinal infection at 24 hours even with small inocular, and at 4-7 days, the patterns of photon emission and remained and healthy throughout the study period. Inoculation of neonates with tagged LB5000 and BJ66 resulted in severe gastrointestinal infections with low and intermediate sizes of inocula respectively. These strains are known to be of reduced virulence in adult mice. These age-related differences in susceptibility emphasize the need to define virulence in the context of age of the host, and implicate maturation of innate resistance factors in determining disease patterns. Identifying these host-factors and further defining the bacterial determinants of virulence in the neonatal host will be facilitated by this noninvasive study of infection using bioluminenscent methods.

  7. Non-conventional passive sensors for monitoring tritium on surfaces

    SciTech Connect

    Gammage, R.B.; Brock, J.L.; Meyer, K.E.

    1995-06-01

    The authors describe development of small passive, solid-state detectors for in-situ measurements of tritium, or other weak beta-emitting radionuclides, on surfaces. One form of detector operates on the principle of thermally stimulated exoelectron emission (TSEE), the other by discharge of an electret ion chamber (EIC). There are currently two specific types of commercially available detector systems that lend themselves to making surface measurements. One is the thin-film BeO on a graphite disc, and the other is the Teflon EIC. Two other types of TSEE dosimeters (ceramic BeO and carbon doped alumina) are described but lack either a suitable commercially available reader or standardized methods of fabrication. The small size of these detectors allows deployment in locations difficult to access with conventional windowless gas-flow proportional counters. Preliminary testing shows that quantitative measurements are realized with exposure times of 1--10 hours for the TSEE dosimeters (at the DOE release guideline of 5,000 dpm/100 cm{sup 2} for fixed beta contamination). The EIC detectors exhibit an MDA of 26,000 dpm/100 cm{sup 2} for a 24 hour exposure. Both types of integrating device are inexpensive and reusable. Measurements can, therefore, be made that are faster, cheaper, safer, and better than those possible with baseline monitoring technology.

  8. Monitoring technology

    NASA Technical Reports Server (NTRS)

    Stevenson, William A. (Inventor)

    1992-01-01

    A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

  9. Monitoring technology

    NASA Technical Reports Server (NTRS)

    Stevenson, William A. (Inventor)

    1989-01-01

    A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

  10. Monitoring well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2002-01-01

    The present invention relates to a monitoring well which includes an enclosure defining a cavity and a water reservoir enclosed within the cavity and wherein the reservoir has an inlet and an outlet. The monitoring well further includes a porous housing borne by the enclosure and which defines a fluid chamber which is oriented in fluid communication with the outlet of the reservoir, and wherein the porous housing is positioned in an earthen soil location below-grade. A geophysical monitoring device is provided and mounted in sensing relation relative to the fluid chamber of the porous housing; and a coupler is selectively moveable relative to the outlet of reservoir to couple the porous housing and water reservoir in fluid communication. An actuator is coupled in force transmitting relation relative to the coupler to selectively position the coupler in a location to allow fluid communication between the reservoir and the fluid chamber defined by the porous housing.

  11. Recreation monitoring

    SciTech Connect

    DiGennaro, B.; Merklein, G.H.

    1995-12-31

    Recreational use and recreational facilities are common features at hydropower projects. In fact, the hydropower industry is a major supplier of recreational opportunities contributing to tourism and rural economic growth in many communities across the country, As demands for public recreation have grown, pressure on the hydropower industry to provide more public access and more facilities has increased. This paper looks at recent developments in the FERC licensing and compliance arenas with regard to planning for and monitoring recreation at hydropower facilities. The paper highlights the increased occurrence of recreation monitoring requirements in license articles and discusses methods for complying with such requirements. The paper also looks at how monitoring data can be used to avoid unnecessary developments and to better plan for future recreation use.

  12. Parental Monitoring

    ERIC Educational Resources Information Center

    Shillington, Audrey M.; Lehman, Stephanie; Clapp, John; Hovell, Melbourne; Sipan, Carol; Blumberg, Elaine

    2005-01-01

    Adolescence is a developmental period during which many youth experiment with risk practices. This paper examined the association of parental monitoring with a range of alcohol and other drug (AOD) use behaviors among high-risk youth, while controlling for other demographic and environmental variables previously found to be associated with AOD…

  13. Monitoring well

    DOEpatents

    Hubbell, J.M.; Sisson, J.B.

    1999-06-29

    A monitoring well is described which includes: a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto. 8 figs.

  14. Damage detection monitoring applications in self-healing concrete structures using embedded piezoelectric transducers and recovery

    NASA Astrophysics Data System (ADS)

    Karaiskos, G.; Tsangouri, E.; Aggelis, D. G.; Deraemaeker, A.; Van Hemelrijck, D.

    2015-07-01

    The ageing, operational and ambient loadings have a great impact in the operational and maintenance cost of concrete structures. Their service life prolongation is of utmost importance and this can be efficiently achieved by using reliable and low-cost monitoring and self-healing techniques. In the present study, the ultrasonic pulse velocity (UPV) method using embedded small-size and low-cost piezoelectric PZT (lead zirconate titanate) ceramic transducers in concrete with self-healing properties is implemented for monitoring not only the setting and hardening phases of concrete since casting time, but also for the detection of damage initiation, propagation and recovery of integrity after healing. A couple of small-scale notched unreinforced concrete beams are subjected to mode-I fracture through three-point bending tests. After a 24-hour healing agent curing period, the beams are reloaded using the same loading scenario. The results demonstrate the excellent performance of the proposed monitoring technique during the hydration, damage generation and recovery periods.

  15. Tritium monitor

    DOEpatents

    Chastagner, Philippe

    1994-01-01

    A system for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream.

  16. Tritium monitor

    DOEpatents

    Chastagner, P.

    1994-06-14

    A system is described for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream. 1 fig.

  17. Sewage Monitors

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  18. Biological monitoring

    SciTech Connect

    Miller, S.

    1984-06-01

    Recent research is reviewed from books, international committees and symposia which describes the usefulness of biological monitoring for exposure to such compounds as organometallic chemicals, carbon monoxide and cyanide. The types of analyses include the following measurements: the concentration of the chemical in various biological media such as blood, urine, and expired air; the concentration of metabolites of the individual chemical in the same media; and determination of nonadverse biological changes resulting from the reaction of the organism to exposure. A main goal of such monitoring is to ensure that the current or past levels of worker exposure are safe, so that such exposure does not involve an unacceptable health risk. It considers routes other than absorption by the lungs and is a good method for evaluating individual exposures.

  19. Monitoring oxygenation.

    PubMed

    Severinghaus, John W

    2011-06-01

    Cyanosis was used for a century after dentists began pulling teeth under 100% N(2)O in 1844 because brief (2 min) severe hypoxia is harmless. Deaths came with curare and potent anesthetic respiratory arrest. Leland Clark's invention of a polarographic blood oxygen tension electrode (1954) was introduced for transcutaneous PO2 monitoring to adjust PEEP and CPAP PO2 to prevent premature infant blindness from excess O2 (1972). Oximetry for warning military aviators was tried after WW II but not used for routine monitoring until Takuo Aoyagi (1973) discovered an equation to measure SaO2 by the ratio of ratios of red and IR light transmitted through tissue as it changed with arterial pulses. Pulse oximetry (1982) depended on simultaneous technology improvements of light emitting red and IR diodes, tiny cheap solid state sensors and micro-chip computers. Continuous monitoring of airway anesthetic concentration and oxygen also became very common after 1980. Death from anesthesia fell 10 fold between 1985 and 2000 as pulse oximetry became universally used, but no proof of a causative relationship to pulse oximetry exists. It is now assumed that all anesthesiologist became much more aware of the dangers of prolonged hypoxia, perhaps by using the pulse oximeters. PMID:21717228

  20. Patient Monitoring

    NASA Technical Reports Server (NTRS)

    1978-01-01

    In photo above, the electrocardiogram of a hospitalized patient is being transmitted by telemetry. Widely employed in space operations, telemetry is a process wherein instrument data is converted to electrical signals and sent to a receiver where the signals are reconverted to usable information. In this instance, heart readings are picked up by the electrode attached to the patient's body and delivered by wire to the small box shown, which is a telemetry transmitter. The signals are relayed wirelessly to the console in the background, which converts them to EKG data. The data is displayed visually and recorded on a printout; at the same time, it is transmitted to a central control station (upper photo) where a nurse can monitor the condition of several patients simultaneously. The Patient Monitoring System was developed by SCI Systems, Inc., Huntsville, Alabama, in conjunction with Abbott Medical Electronics, Houston, Texas. In developing the system, SCI drew upon its extensive experience as a NASA contractor. The company applied telemetry technology developed for the Saturn launch vehicle and the Apollo spacecraft; instrumentation technology developed for heart, blood pressure and sleep monitoring of astronauts aboard NASA's Skylab long duration space station; and communications technology developed for the Space Shuttle.

  1. Relationship between ventricular ectopic beat frequency and heart rate: study in patients with severe arrhythmias.

    PubMed

    Acanfora, D; De Caprio, L; Di Palma, A; Furgi, G; Ing, F M; Migaux, M L; Rengo, F

    1993-04-01

    To evaluate and quantify the relationship between premature ventricular contractions (PVCs) and heart rate (HR), 57 patients (48 men and 8 women, mean age 59.8 +/- 7.9 years) with severe PVCs (Lown-Wolf grade > or = 3a) over 24 hours of Holter monitoring were studied. Twenty had no coronary artery disease (CAD), 25 had angiographically documented CAD, and 12 had acute myocardial infarction. All parameters of the 24-hour recordings from two ECG leads were measured by a Holter analyzer designed in our laboratory, based on fast microprocessors and controlled by a microcomputer. Scatter diagrams of the number of PVCs per minute as a function of HR and correlation coefficient were computed for various HR values corresponding to a total number of minutes greater than five. A positive correlation (r > or = 0.35) was found in most patients without CAD (85%); there was a complex relationship between the strength of the correlation and the presence of CAD or acute myocardial infarction because of a greater variability in the results of correlation coefficient analysis (coefficient of variation 62%, 208%, and 145% in patients without CAD, with CAD, and with acute myocardial infarction, respectively). The incidence of a positive correlation was similar in patients with Lown-Wolf grade III (63%), IVa (82%), or > or = IVb (67%) arrhythmias. The reproducibility of the correlation coefficient of the relationship between PVC frequency and HR was tested in 15 patients. The mean value of the correlation coefficient was 0.801 +/- 0.169 for the first test and 0.805 +/- 0.22 (p = NS) for the second test.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7682033

  2. Relationship between ventricular ectopic beat frequency and heart rate: study in patients with severe arrhythmias.

    PubMed

    Acanfora, D; De Caprio, L; Di Palma, A; Furgi, G; Ing, F M; Migaux, M L; Rengo, F

    1993-04-01

    To evaluate and quantify the relationship between premature ventricular contractions (PVCs) and heart rate (HR), 57 patients (48 men and 8 women, mean age 59.8 +/- 7.9 years) with severe PVCs (Lown-Wolf grade > or = 3a) over 24 hours of Holter monitoring were studied. Twenty had no coronary artery disease (CAD), 25 had angiographically documented CAD, and 12 had acute myocardial infarction. All parameters of the 24-hour recordings from two ECG leads were measured by a Holter analyzer designed in our laboratory, based on fast microprocessors and controlled by a microcomputer. Scatter diagrams of the number of PVCs per minute as a function of HR and correlation coefficient were computed for various HR values corresponding to a total number of minutes greater than five. A positive correlation (r > or = 0.35) was found in most patients without CAD (85%); there was a complex relationship between the strength of the correlation and the presence of CAD or acute myocardial infarction because of a greater variability in the results of correlation coefficient analysis (coefficient of variation 62%, 208%, and 145% in patients without CAD, with CAD, and with acute myocardial infarction, respectively). The incidence of a positive correlation was similar in patients with Lown-Wolf grade III (63%), IVa (82%), or > or = IVb (67%) arrhythmias. The reproducibility of the correlation coefficient of the relationship between PVC frequency and HR was tested in 15 patients. The mean value of the correlation coefficient was 0.801 +/- 0.169 for the first test and 0.805 +/- 0.22 (p = NS) for the second test.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Twenty-Four-Hour Ambulatory Blood Pressure Monitoring in Hypertension

    PubMed Central

    2012-01-01

    Executive Summary Objective The objective of this health technology assessment was to determine the clinical effectiveness and cost-effectiveness of 24-hour ambulatory blood pressure monitoring (ABPM) for hypertension. Clinical Need: Condition and Target Population Hypertension occurs when either systolic blood pressure, the pressure in the artery when the heart contracts, or diastolic blood pressure, the pressure in the artery when the heart relaxes between beats, are consistently high. Blood pressure (BP) that is consistently more than 140/90 mmHg (systolic/diastolic) is considered high. A lower threshold, greater than 130/80 mmHg (systolic/diastolic), is set for individuals with diabetes or chronic kidney disease. In 2006 and 2007, the age-standardized incidence rate of diagnosed hypertension in Canada was 25.8 per 1,000 (450,000 individuals were newly diagnosed). During the same time period, 22.7% of adult Canadians were living with diagnosed hypertension. A smaller proportion of Canadians are unaware they have hypertension; therefore, the estimated number of Canadians affected by this disease may be higher. Diagnosis and management of hypertension are important, since elevated BP levels are related to the risk of cardiovascular disease, including stroke. In Canada in 2003, the costs to the health care system related to the diagnosis, treatment, and management of hypertension were over $2.3 billion (Cdn). Technology The 24-hour ABPM device consists of a standard inflatable cuff attached to a small computer weighing about 500 grams, which is worn over the shoulder or on a belt. The technology is noninvasive and fully automated. The device takes BP measurements every 15 to 30 minutes over a 24-to 28-hour time period, thus providing extended, continuous BP recordings even during a patient’s normal daily activities. Information on the multiple BP measurements can be downloaded to a computer. The main detection methods used by the device are auscultation and

  4. Seismic monitoring of Central Asia territory in KNDC.

    NASA Astrophysics Data System (ADS)

    Mukambayev, Aidyn; Mikhailova, Natalia

    2015-04-01

    The Central Asia territory includes the territory of five post-Soviet countries: Kazakhstan, Kyrgyzstan, Tajikistan, Turkmenistan, and Uzbekistan. Every country has its own independent network of seismic observations and Data Processing Center aimed at every day seismic monitoring of one country territory. However, seismic hazard of Central Asia territory is stipulated by one geodynamic system that generates simultaneous large earthquakes on the territory of different countries. Thus, it is necessary to observe seismic situation for the whole region for emergency situations and for compilation of joint seismic bulletins of Central Asia region. A new contemporary network of seismic observations operated by the Institute of Geophysical Researches has been installed in Kazakhstan during last 15 years. Mainly, these are seismic arrays located throughout the country perimeter. The arrays were constructed under support of the CTBTO, and AFTAC. There are also IRIS and CAREMON stations. All data arrive to KNDC (Kazakhstan National Data Center) in real time mode. In addition, KNDC receives data in real time from stations Zalesovo (Russia), Alibek (Turkmenistan), Ala-Archa and Tokmak (Kyrgyzstan). Arrival times in the form of tables are received with 24-hours delay from almost 20 Kazakhstan stations belonging to SEME MES RK. This observation system allows monitoring the Central Asian seismicity by earthquakes with representative magnitude more than 3.5. In some regions, the events with magnitude 1.5 are recorded. As result, different products with different operativity are created for Central Asia territory: -bulletin of urgent alerts; -automatic seismic bulletin; -interact