Science.gov

Sample records for 24-hour holter monitoring

  1. Holter monitor (24h)

    MedlinePlus

    ... the machine gets an accurate recording of the heart's activity. While wearing the device, avoid: Electric blankets High- ... Holter monitoring is used to determine how the heart responds to normal activity. The monitor may also be used: After a ...

  2. Prognostic indices among hypertensive heart failure patients in Nigeria: the roles of 24-hour Holter electrocardiography and 6-minute walk test

    PubMed Central

    Mene-Afejuku, Tuoyo O; Balogun, Michael O; Akintomide, Anthony O; Adebayo, Rasaaq A

    2017-01-01

    Background Hypertensive heart failure (HHF) is associated with a poor prognosis. There is paucity of data in Nigeria on prognosis among HHF patients elucidating the role of 24-hour Holter electrocardiogram (ECG) in concert with other risk factors. Objective The aim of this study was to determine the prognostic utility of 24-hour Holter ECG, the 6-minute walk test (6-MWT), echocardiography, clinical and laboratory parameters among HHF patients. Methods A total of 113 HHF patients were recruited and followed up for 6 months. Thirteen of these patients were lost to follow-up, and as a result only 100 HHF patients were analyzed. All the patients underwent baseline laboratory tests, echocardiography, 24-hour Holter ECG and the 6-MWT. HHF patients were analyzed as “mortality vs alive” and as “events vs no-events” based on the outcome at the end of 6 months. Events was defined as HHF patients who were rehospitalized for heart failure (HF), had prolonged hospital stay or died. No-events group was defined as HHF patients who did not meet the criteria for the events group. Results HHF patients in the mortality group (n = 7) had significantly higher serum urea (5.71 ± 2.07 mmol/L vs 3.93 ± 1.45 mmol/L, p = 0.003) than that in those alive. After logistic regression, high serum urea conferred increased mortality risk (p = 0.035). Significant premature ventricular complexes (PVCs) on 24-hour Holter ECG following logistic regression were also significantly higher (p = 0.015) in the mortality group than in the “alive” group (n = 93) at the end of the 6-month follow-up period. The 6-minute walk distance (6-MWD) was least among the HHF patients who died (167.26 m ± 85.24 m). However, following logistic regression, the 6-MWT was not significant (p = 0.777) for predicting adverse outcomes among HHF patients. Patients in the events group (n = 41) had significantly higher New York Heart Association (NYHA) class (p = 0.001), Holter-detected ventricular tachycardia (VT; p

  3. Holter and Event Monitors

    MedlinePlus

    ... Monitors What Are... Related Topics Arrhythmia Electrocardiogram Heart Failure Heart Palpitations Sudden Cardiac Arrest Send a link to ... Angina Arrhythmia Atrial Fibrillation Clinical Trials Electrocardiogram Heart Failure Heart Palpitations Stroke Sudden Cardiac Arrest Rate This Content: ...

  4. Relative prognostic value of rest thallium-201 imaging, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring after acute myocardial infarction

    SciTech Connect

    Hakki, A.H.; Nestico, P.F.; Heo, J.; Unwala, A.A.; Iskandrian, A.S.

    1987-07-01

    Rest thallium-201 scintigraphy, radionuclide ventriculography and 24 hour Holter monitoring are acceptable methods to assess myocardial necrosis, performance and electrical instability. This study examined the relative value of the three tests, when obtained a mean of 7 days after acute myocardial infarction, in predicting 1 year mortality in 93 patients. Planar thallium-201 images were obtained in three projections and were scored on a scale of 0 to 4 in 15 segments (normal score = 60). Patients were classified as having high risk test results as follows: thallium score less than or equal to 45 (33 patients), left ventricular ejection fraction less than or equal to 40% (51 patients) and complex ventricular arrhythmias on Holter monitoring (36 patients). During the follow-up of 6.4 +/- 3.4 months (mean +/- SD), 15 patients died of cardiac causes. All three tests were important predictors of survival by univariate Cox survival analysis; the thallium score, however, was the only important predictor by multivariate analysis. The predictive power of the thallium score was comparable with that of combined ejection fraction and Holter monitoring (chi-square = 21 versus chi-square = 22). Thus, rest thallium-201 imaging performed before hospital discharge provides important prognostic information in survivors of acute myocardial infarction which is comparable with that provided by left ventricular ejection fraction and Holter monitoring. Patients with a lower thallium score (large perfusion defects) are at high risk of cardiac death during the first year after infarction.

  5. Differences in the Slope of the QT-RR Relation Based on 24-Hour Holter ECG Recordings between Cardioembolic and Atherosclerotic Stroke

    PubMed Central

    Fujiki, Akira; Sakabe, Masao

    2016-01-01

    Objective Detecting paroxysmal atrial fibrillation in patients with ischemic stroke presenting in sinus rhythm is difficult because such episodes are often short, and they are also frequently asymptomatic. It is possible that the ventricular repolarization dynamics may reflect atrial vulnerability and cardioembolic stroke. Hence, we compared the QT-RR relation between cardioembolic stroke and atherosclerotic stroke during sinus rhythm. Methods The subjects comprised 62 consecutive ischemic stroke patients including 31 with cardioembolic strokes (71.8±12.7 years, 17 men) and 31 with atherosclerotic strokes (74.8±10.8 years, 23 men). The QT and RR intervals were measured from ECG waves based on a 15-sec averaged ECG during 24-hour Holter recording using an automatic QT analyzing system. The QT interval dependence on the RR interval was analyzed using a linear regression line for each subject ([QT]=A[RR]+B; where A is the slope and B is the y-intercept). Results The mean slope of the QT-RR relation was significantly greater in cardioembolic stroke than in atherosclerotic stroke (0.187±0.044 vs. 0.142±0.045, p<0.001). The mean QT, RR, or QTc during 24-hour Holter recordings did not differ between them. An increased slope (≥0.14) of the QT-RR regression line could predict cardioembolic stroke with 97% sensitivity, 55% specificity and a positive predictive value of 64%. Conclusion The increased slope of the QT-RR linear regression line based on 24-hour Holter ECG in patients with ischemic stroke presenting in sinus rhythm may therefore be a simple and useful marker for cardioembolic stroke. PMID:27746427

  6. Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?

    PubMed Central

    Mansouri, Kaweh; Weinreb, Robert N.; Medeiros, Felipe A.

    2013-01-01

    Although intraocular pressure (IOP) is the only treatable risk factor for glaucoma, its 24-hour behavior is poorly understood. Conflicting information is available in the literature with regard to the importance and predictive value of IOP peaks and fluctuations on the risk of glaucoma development and progression. This may be secondary to lack of prospective studies designed to address this issue. This article critically reviews the current evidence for the importance of 24-h IOP measurements in glaucoma and discusses shortcomings of current methods to assess 24-h IOP data, drawing attention to new developments in this field. PMID:23697618

  7. Cardiovascular Outcomes in Patients with Normal and Abnormal 24-Hour Ambulatory Blood Pressure Monitoring

    PubMed Central

    Iqbal, P.; Stevenson, Louise

    2011-01-01

    Introduction. 24-hour ambulatory blood pressure monitoring (ABPM) plays an important role in assessing cardiovascular prognosis, through presence or absence of ABPM-related prognostic features. Objectives. To study relationship between 24-hour ABPM and cardiovascular outcomes in patients from Chesterfield Royal Hospital. Material and Methods. Over 12 months from the 1st of August 2002, 1187 individuals had 24-hour ABPM performed. Cardiovascular outcomes were studied in a subset (297) of the original cohort, made up by every 4th consecutive subject. The following ABPM-related prognostic features were studied—high day time systolic and diastolic BP (≥135, ≥85 mmHg), high night time systolic and diastolic BP (≥120 mmHg, ≥75 mmHg), absence of nocturnal dip (≤10% fall in night time SBP), high early morning SBP (≥140 mmHg), and morning surge (≥20/15 mmHg). The cardiovascular outcomes studied in the fourth table included fatal and nonfatal MI, new diagnosis of angina, acute coronary syndrome, sudden cardiac death, cardiac arrhythmias, acute LVF, cerbrovascular events, peripheral vascular disease, abdominal aortic aneurysm, and CKD stage 3 or above. Results. Over a followup period of 2015 ± 116 days (1720–2305 days) 82 cardiovascular events occurred in 61 subjects. Cardiac arrhythmias were the most common CV outcome (34 events) followed by cerebrovascular events (15). Statistically significant associations found were between cerebrovascular events and absent nocturnal dip ≤ 10% (P = .05) and high day time DBP (P = .029), peripheral vascular disease and morning surge ≥ 20/15 mmHg (P = .014), cardiac arrhythmias and high day time and night time DBP (P = .009 and .033, resp.). Conclusion. Significant associations were found between cerebrovascular events and absent nocturnal dip ≤ 10% and high day time DBP, peripheral vascular disease and morning surge ≥ 20/15 mmHg, cardiac arrhythmias and high day time and night time DBP. PMID

  8. ECG Holter monitor with alert system and mobile application

    NASA Astrophysics Data System (ADS)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  9. The electrocardiographic Holter monitoring in experimental veterinary practice.

    PubMed

    Scheer, P; Svoboda, P; Sepsi, M; Janecková, K; Doubek, J

    2010-01-01

    The long-term electrocardiographic recording with retrospective evaluation (Holter system) has been widely used not only in cardiology, but also in other disciplines of internal medicine and in pharmaceutical research. The Holter system can be used in mini-pig, sheep, dog, cat, rabbit, ferret, and rat. In this paper hardware, software, and anesthesia requirements are summarized with respect to the experimental work with various species. As the Holter systems work in bipolar mode, the use of bipolar leads in sagittal and transversal planes has been proved to be the most appropriate because of large amplitude of QRS complex and uncomplicated consequent automatic analysis of the record. In conclusion, Holter electrocardiography represents a simple and applicable method for monitoring the electrical activity of the heart in small animals' experimental studies.

  10. The Use of Continuous Electrocardiographic Holter Monitoring in Pediatric Cardiology

    PubMed Central

    Begic, Zijo; Begic, Edin; Mesihovic-Dinarevic, Senka; Masic, Izet; Pesto, Senad; Halimic, Mirza; Kadic, Almira; Dobraca, Amra

    2016-01-01

    Objective: To show the place and role of continuous electrocardiographic twenty-four-hour ECG monitoring in daily clinical practice of pediatric cardiologists. Methods: According to protocol, 2753 patients underwent dynamic continuous ECG Holter monitoring (data collected from the “Register of ECG Holter monitoring” of Pediatric Clinic, UCC Sarajevo in period April 2003- April 2015). Results: There were 50,5% boys and 49,5% girls, aged from birth to 19 years (1,63% - neonates and infants, 2,6% - toddlers, 9,95% - preschool children, 35,5% - gradeschoolers and 50,3% children in puberty and adolescence). In 68,1% of patients Holter was performed for the first time. Indications for conducting Holter were: arrhythmias in 42,2% cases, precordial pain in 23,5%, suspicion of pre-excitation and/or pre-excitation in 10%, crisis of consciousness in 8%, uncorrected congenital/acquired heart defects in 4,2%, operated heart defects in 3,7%, hypertension in 3,1% cases, control of the pacemaker in 1,63% and other causes in 3,5% cases. Discharge diagnosis after ECG Holter monitoring were: insignificant arrhythmias in 47,1% cases, wandering pacemaker in 21,3%, pre-excitation in 16,2%, benign ventricular premature beats in 6,3%, atrioventricular block in 3%, sinus pause in 2.2% cases and other arrhythmias in 3,5%. In mentioned period 57 cases of Wolf Parkinson White syndrome were registered, in 4,5% of patients antiarrhythmic therapy was administered. Radiofrequent ablation was performed in 23 cases. Conclusion: The development of pediatric cardiac surgery has initiated development of pediatric arrhythmology as imperative segment of pediatric cardiology. Continuous ECG Holter monitoring has become irreplaceable method in everyday diagnostics and therapy of arrhythmias in children. PMID:27708487

  11. Discussion of "Computational Electrocardiography: Revisiting Holter ECG Monitoring".

    PubMed

    Baumgartner, Christian; Caiani, Enrico G; Dickhaus, Hartmut; Kulikowski, Casimir A; Schiecke, Karin; van Bemmel, Jan H; Witte, Herbert

    2016-08-05

    This article is part of a For-Discussion-Section of Methods of Information in Medicine about the paper "Computational Electrocardiography: Revisiting Holter ECG Monitoring" written by Thomas M. Deserno and Nikolaus Marx. It is introduced by an editorial. This article contains the combined commentaries invited to independently comment on the paper of Deserno and Marx. In subsequent issues the discussion can continue through letters to the editor.

  12. [Individual peculiarities of adaptation to long-term space flights: 24-hour heart rhythm monitoring

    NASA Technical Reports Server (NTRS)

    Baevskii, R. M.; Bogomolov, V. V.; Gol'dberger, A. L.; Nikulina, G. A.; Charl'z, D. B.; Goldberger, A. L. (Principal Investigator); Charles, J. B. (Principal Investigator)

    2000-01-01

    Presented are results of studying 24-hr variability of the cardiac rhythm which characterizes individual difference in reactions of two crew members to the same set of stresses during a 115-day MIR mission. Spacelab (USA) cardiorecorders were used. Data of monitoring revealed significantly different baseline health statuses of the cosmonauts. These functional differences were also observed in the mission. In one of the cosmonauts, the cardiac regulation changed over to a more economic functioning with the autonomous balance shifted towards enhanced sympathetic activity. After 2-3 months on mission he had almost recovered pre-launch level of regulation. In the other, the regulatory system was appreciably strained at the beginning of the mission as compared with preflight baseline. Later on, on flight months 2-3, this strain kept growing till a drastic depletion of the functional reserve. On return to Earth, this was manifested by a strong stress reaction with a sharp decline in power of high-frequency and grow in power of very low frequency components of the heart rhythm. The data suggest that adaptation to space flight and reactions in the readaptation period are dependent on initial health status of crew members, and functional reserve.

  13. [Individual peculiarities of adaptation to long-term space flights: 24-hour heart rhythm monitoring].

    PubMed

    Baevskiĭ, R M; Bogomolov, V V; Gol'dberger, A L; Nikulina, G A; Charl'z, D B

    2000-01-01

    Presented are results of studying 24-hr variability of the cardiac rhythm which characterizes individual difference in reactions of two crew members to the same set of stresses during a 115-day MIR mission. Spacelab (USA) cardiorecorders were used. Data of monitoring revealed significantly different baseline health statuses of the cosmonauts. These functional differences were also observed in the mission. In one of the cosmonauts, the cardiac regulation changed over to a more economic functioning with the autonomous balance shifted towards enhanced sympathetic activity. After 2-3 months on mission he had almost recovered pre-launch level of regulation. In the other, the regulatory system was appreciably strained at the beginning of the mission as compared with preflight baseline. Later on, on flight months 2-3, this strain kept growing till a drastic depletion of the functional reserve. On return to Earth, this was manifested by a strong stress reaction with a sharp decline in power of high-frequency and grow in power of very low frequency components of the heart rhythm. The data suggest that adaptation to space flight and reactions in the readaptation period are dependent on initial health status of crew members, and functional reserve.

  14. Prevalence of Masked Hypertension: a Population-Based Survey in a Large City by Using 24-Hour Ambulatory Blood Pressure Monitoring

    PubMed Central

    Kim, Sun-Woong; Choi, Eun-Hee; Kim, Ji-Hyun; Nah, Deuk-Young; Shin, Sung-Joon; Gu, Namyi

    2016-01-01

    Background and Objectives We estimated the prevalence of hypertension and hypertension subtypes in a large semi-urban city in Korea, using 24-hour ambulatory blood pressure monitoring (ABPM) in a randomly selected sample population. Subjects and Methods A random sample (aged 20-65 years) from a city with an adult population of approximately 600000 was selected by using a list-assisted random digit dialing method. The 24-hour ABPM and conventional blood pressure measurement (CBPM) of these individuals were obtained. Results Among the 496 participants, valid 24-hour ABPM and CBPM were obtained from 462 (93%) individuals. The estimated prevalence of hypertension in Goyang was 17.54% by CBPM and 32.70% by 24-hour ABPM (p<0.01). In the age stratified analysis, both CBPM and 24-hour ABPM showed increased prevalence of hypertension with age. The estimated prevalence of masked hypertension was 16.22% and that of white-coat hypertension was 1.08%. Men had a higher prevalence of masked hypertension than women (20.79% vs. 11.86%, p=0.0295). The estimated prevalence of masked hypertension was 17.5%, 20.58%, 24.34%, and 13.29% in the age categories of 30s, 40s, 50s, and 60s, respectively. The estimated prevalence of masked uncontrolled hypertension was 26.79% in patients with hypertension who were taking antihypertensive medications. Conclusion The estimated prevalence of hypertension by 24-hour ABPM was higher than that by CBPM, revealing high prevalence of masked hypertension. The high prevalence of masked hypertension supports the adoption of ABPM in the national population survey and clinical practice to improve public health and reduce health care costs. PMID:27721860

  15. [Comparison of the data of 24-hour ECG monitoring and the condition of the coronary bed in patients with the variants of the course of unstable stenocardia].

    PubMed

    Karpov, Iu A; Pomerantsev, E V; Shibleva, V V; Merkulova, I N; Khakimov, A G; Podinovskaia, Ia A; Setin, V F

    1992-03-01

    A total of 232 patients with various clinical types of unstable angina pectoris were examined. All the patients underwent coronary angiographic studies, 24-hour ECG monitoring. In 40.5% of the patients, 24-hour monitoring revealed transient ST segment changes which were not accompanied by pain in 47% of the cases. ST segment changes were equally encountered in patients with one-, two-, and three-vessel disease in the presence or absence of pain. Ischemic ST segment changes generally occurred with an anginal episode in patients with crescendo unstable angina, whereas in those with more prolonged and intensified pain and angina at rest in particular, silent myocardial ischemic episodes were significantly more frequently recorded, which were more common in these patients with multivessel disease.

  16. Effect of burden and origin sites of premature ventricular contractions on left ventricular function by 7-day Holter monitor

    PubMed Central

    Xu, Wenhua; Li, Mingfang; Chen, Minglong; Yang, Bing; Wang, Daowu; Kong, Xiangqing; Chen, Hongwu; Ju, Weizhu; Gu, Kai; Cao, Kejiang; Liu, Hailei; Jiang, Qi; Shi, Jiaojiao; Cui, Yan; Wang, Hong

    2015-01-01

    Abstract Recent studies have shown that premature ventricular contractions (PVCs) could enlarge the heart, but its risk factors are incompletely understood as a single 24-hour recording cannot reflect the true PVC burden due to day-to-day variability. Our purpose was to investigate the effect of burden and origin sites on left ventricular (LV) function in patients with PVCs by 7-day Holter electrocardiography (ECG). From May 2012 to August 2013, 112 consecutive patients with PVCs were recruited from the authors' affiliated hospital. All patients received 2-dimensional transthoracic echocardiography, 12-lead routing ECG and 7-days Holter ECG. Serum N-terminal pro-brain natriuretic peptide (NT-proBNP) levels were measured. A total of 102 participants with PVCs were included in the final analysis. Origin of PVCs from the tricuspid annulus had the highest burden and NT-proBNP level. LV papillary muscle had a higher LV ejection fraction (EF) level and a lower LV end-systolic dimension (ESD) than other PVC foci (P<0.05). The high burden group had a higher LV end-diastolic dimension (EDD) and LVESD but lower LVEF than the other two groups (P<0.05). Female, older age, physical work, and history of PVCs had a significantly positive correlation with symptoms. Male, older age, physical work, and high burden were positive predictors of enlarged LVEDD, LVESD and higher serum NT-proBNP level, but lower LVEF. Seven-day dynamic ECG Holter monitor showed the true PVC burden on patients with PVCs. PVCs with a lower burden or origin from the LV papillary muscle and the fascicle were relatively benign, while PVCs with a higher burden or origin from the tricuspid annulus may lead to cardiac dysfunction. PMID:26668581

  17. [THE INFLUENCE OF CYTOFLAVIN AND CARDIOXIPIN ON THE PARAMETERS OF 24-HOUR ARTERIAL PRESSURE MONITORING IN PATIENTS WITH CHRONIC CEREBRAL CIRCULATION INSUFFICIENCY, ARTERIAL HYPERTENSION AND HYPERCHOLESTEROLEMIA].

    PubMed

    Vodop'ianova, O A; Moiseeva, I Ia; Rodina, O P; Kustikova, I N; Antropova, N V

    2015-01-01

    This comparative study of the influence of cytoflavin and cardioxipin on the parameters of 24-hour arterial pressure monitoring in 56 patients with chronic cerebral circulation insufficiency, arterial hypertension and hypercholesterolemia included 32 women and 24 men aged 42-72 years divided into 3 groups matchedfor the stage of diseases, age, sex, severity of AH, total cholesterol level, and antihypertensive therapy. Patients of group 1 were treated without cytoflavin and cardioxipin. Those in group 2 received daily i/v droplet infusion of 10 mg/kg cardioxipin (20-30 droplets/min). Patients of group 3 were given daily i/v droplet infusion of 10 ml cytoflavin in 200 ml 0.9% sodium chloride solution for 10 days. 24-hour arterial pressure monitoring was used to estimate the influence of the two drugs on systolic and diastolic pressure, its daily rhythm, AP variability and frequency of elevation. The study showed that both therapeutic modalities improved daily AP rhythm as manifested in a significant increase of the number of patients with the dipper rhythm and a decrease in the number of systolic/diastolic non-dipper patients. Moreover cytoflavin significantly decreased the number of systolic over-dippers compared with control group.

  18. Gastroesophageal and pharyngeal reflux detection using impedance and 24-hour pH monitoring in asymptomatic subjects: defining the normal environment.

    PubMed

    Oelschlager, Brant K; Quiroga, Elina; Isch, John A; Cuenca-Abente, Federico

    2006-01-01

    Airway symptoms are often caused by aspiration of refluxed materials into the larynx. In this study we sought to define the frequency, character, and proximal extent of refluxed contents - including nonacid reflux-in normal subjects using intraluminal impedance to improve our understanding of the relationship between reflux and aspiration. Ten subjects, who had no symptoms of gastroesophageal reflux disease or airway disease, underwent impedance/pH monitoring with a catheter that allowed simultaneous esophageal and pharyngeal monitoring. Impedance detected 496 gastroesophageal reflux episodes in the 10 subjects during 240 hours of study. The majority, 399 (81% of the total) were acid reflux episodes (pH < 4). Ninety-seven were nonacid (pH > 4). Most reflux episodes (348 of 496) reached the mid esophagus (9 cm above lower esophageal sphincter). There were 51 reflux episodes that reached the pharynx (PR). Only 13 (25%) of PR were acidic (pH < 4), while 38 were nonacid. Twenty-six PR episodes were liquid and 25 were mixed (liquid and gas). The median number of PR episodes measured with impedance was 5 (0-10). In asymptomatic subjects, most episodes of gastroesophageal reflux are acidic and reach the midesophagus. Reflux into the PR appears to be more common than previously believed, and most of these episodes are not acidic. Thus, traditional 24-hour pH monitoring may underestimate the presence of pharyngeal reflux. The combination of impedance with pH monitoring markedly enhances our ability to accurately detect potential microaspiration.

  19. Holter registers and metabolic syndrome

    NASA Astrophysics Data System (ADS)

    Muñoz-Diosdado, A.; Ramírez-Hernández, L.; Aguilar-Molina, A. M.; Zamora-Justo, J. A.; Gutiérrez-Calleja, R. A.; Virgilio-González, C. D.

    2014-11-01

    There is a relationship between the state of the cardiovascular system and metabolic syndrome (MS). A way to diagnose the heart state of a person is to monitor the electrical activity of the heart using a 24 hours Holter monitor. Scanned ECG signal can be analyzed beat-by-beat by algorithms that separate normal of abnormal heartbeats. If the percentage of abnormal heartbeats is too high it could be argued that the patient has heart problems. We have algorithms that can not only identify the abnormal heartbeats, but they can also classify them, so we classified and counted abnormal heartbeats in patients with MS and subjects without MS. Most of our patients have large waist circumference, high triglycerides and high levels of LDL (high-density lipoprotein) cholesterol although some of them have high blood pressure. We enrolled adult patients with MS free of diabetes in a four month lifestyle intervention program including diet and physical aerobic exercise, and compared with healthy controls. We made an initial registration with a Holter, and 24 hours ECG signal is analyzed to identify and classify the different types of heartbeats. The patients then begin with diet or exercise (at least half an hour daily). Periodically Holter records were taken up and we describe the evolution in time of the number and type of abnormal heartbeats. Results show that the percentage of abnormal heartbeats decreases over time, in some cases the decline is very significant, and almost a reduction to half or less of abnormal heartbeats after several months since the patients changed their eating or physical activity habits.

  20. Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

    SciTech Connect

    Carbaugh, Eugene H.

    2008-10-01

    The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

  1. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    PubMed

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  2. Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

    NASA Technical Reports Server (NTRS)

    Baevsky, R. M.; Bennett, B. S.; Bungo, M. W.; Charles, J. B.; Goldberger, A. L.; Nikulina, G. A.

    1997-01-01

    This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.

  3. Human prolactin - 24-hour pattern with increased release during sleep.

    NASA Technical Reports Server (NTRS)

    Sassin, J. F.; Weitzman, E. D.; Kapen, S.; Frantz, A. G.

    1972-01-01

    Human prolactin was measured in plasma by radioimmunoassay at 20-minute intervals for a 24-hour period in each of six normal adults, whose sleep-wake cycles were monitored polygraphically. A marked diurnal variation in plasma concentrations was demonstrated, with highest values during sleep. Periods of episodic release occurred throughout the 24 hours.

  4. 24-Hour Relativistic Bit Commitment

    NASA Astrophysics Data System (ADS)

    Verbanis, Ephanielle; Martin, Anthony; Houlmann, Raphaël; Boso, Gianluca; Bussières, Félix; Zbinden, Hugo

    2016-09-01

    Bit commitment is a fundamental cryptographic primitive in which a party wishes to commit a secret bit to another party. Perfect security between mistrustful parties is unfortunately impossible to achieve through the asynchronous exchange of classical and quantum messages. Perfect security can nonetheless be achieved if each party splits into two agents exchanging classical information at times and locations satisfying strict relativistic constraints. A relativistic multiround protocol to achieve this was previously proposed and used to implement a 2-millisecond commitment time. Much longer durations were initially thought to be insecure, but recent theoretical progress showed that this is not so. In this Letter, we report on the implementation of a 24-hour bit commitment solely based on timed high-speed optical communication and fast data processing, with all agents located within the city of Geneva. This duration is more than 6 orders of magnitude longer than before, and we argue that it could be extended to one year and allow much more flexibility on the locations of the agents. Our implementation offers a practical and viable solution for use in applications such as digital signatures, secure voting and honesty-preserving auctions.

  5. [Indices of static and dynamic components of pressure load (assessed by 24-hour blood pressure monitoring) and the state of renal function in patients with essential hypertension].

    PubMed

    Zelveian, P A; Buniatian, M S; Oshchepkova, E V; Lazareva, N V; Rogoza, A N

    2011-01-01

    Aim of this study was to evaluate possible relationship between parameters of blood pressure (BP) profile and glomerular filtration rate in patients (pts) with I-II stage essential hypertension (EH). Material and methods. We studied 120 pts (97 men), aged 23-65 (50,2+/-0,6) years with I (n=98) and II (n=22) stage EH. In BP profile (SL-90207) we calculated 24-hour, daytime, nighttime values of systolic, diastolic, pulse pressures (SBP, DBP, PP), time load (TL), variability and nocturnal fall (NF) of BP. The state of renal function was assessed by measurement of glomerular filtration rate (GFR) calculated by the Cockcroft formula. Results. After nonlinear statistical analysis by Gauss-Newton all patients were divided into three groups according to GFR tertiles. Significant differences were found between these groups by 24-hour, nighttime and daytime values of SBP and DBP. Values of SBP were the lowest in group II. In group II lowest values of PP were also observed, but statistically significant differences were found only in nocturnal PP values between groups II and III. There were no significant differences between groups by TL and NF of BP. In group Ill (high GFR) variability of daytime values of SBP and DBF were significantly higher. Univariate correlation analysis showed statistically significant negative relationship between GFR and nocturnal PP in patients with lowest level of GFR. Positive correlations between nocturnal values of PP and GFR in groups II and III were also observed. Conclusion. These results indicated the presence of strong relationship between high values of nocturnal PP and decreasing of glomerular filtration rate in patients with EH and thus confirmed significance of "constant" and "dynamic" components of pressure load as a marker of impairment of renal function.

  6. 24-Hour Academic Libraries: Adjusting to Change

    ERIC Educational Resources Information Center

    Bowman, Adam C.

    2013-01-01

    The purpose of this study was to explore the adaptive measures that academic libraries perform when implementing and operating a 24-hour schedule. Five in-depth interviews were conducted with current managerial-level librarians at 24-hour academic libraries. The exploratory interviews revealed similar measures for security, budgeting, employee…

  7. Ambulatory blood pressure monitoring: importance of sampling rate and duration--48 versus 24 hours--on the accurate assessment of cardiovascular risk.

    PubMed

    Hermida, Ramón C; Ayala, Diana E; Fontao, María J; Mojón, Artemio; Fernández, José R

    2013-03-01

    Independent prospective studies have found that ambulatory blood pressure (BP) monitoring (ABPM) is more closely correlated with target organ damage and cardiovascular disease (CVD) risk than clinic BP measurement. This is based on studies in which BP was sampled every 15-30 min for ≤24 h, without taking into account that reproducibility of any estimated parameter from a time series to be potentially used for CVD risk assessment might depend more on monitoring duration than on sampling rate. Herein, we evaluated the influence of duration (48 vs. 24 h) and sampling rate of BP measurements (form every 20-30 min up to every 2 h) on the prognostic value of ABPM-derived parameters. We prospectively studied 3344 subjects (1718 men/1626 women), 52.6 ± 14.5 yrs of age, during a median follow-up of 5.6 yrs. Those with hypertension at baseline were randomized to ingest all their prescribed hypertension medications upon awakening or ≥1 of them at bedtime. At baseline, BP was measured at 20-min intervals from 07:00 to 23:00 h and at 30-min intervals at night for 48 h, and physical activity was simultaneously monitored every min by wrist actigraphy to accurately derive the awake and asleep BP means. Identical assessment was scheduled annually and more frequently (quarterly) if treatment adjustment was required. ABPM profiles were modified to generate time series of identical 48-h duration but with data sampled at 1- or 2-h intervals, or shorter, i.e., first 24 h, time series with data sampled at the original rate (daytime 20-min intervals/nighttime 30-min intervals). Bland-Altman plots indicated that the range of individual differences in the estimated awake and asleep systolic (SBP) and diastolic BP (DBP) means between the original and modified ABPM profiles was up to 3-fold smaller for data sampled every 1 h for 48 h than for data sampled every 20-30 min for the first 24 h. Reduction of ABPM duration to just 24 h resulted in error of the

  8. Utility of ambulatory 24-hour esophageal pH and motility monitoring in noncardiac chest pain: report of 90 patients and review of the literature.

    PubMed

    Lacima, Gloria; Grande, Luis; Pera, Manuel; Francino, Antonio; Ros, Emilio

    2003-05-01

    It is unclear whether prolonged motility monitoring improves the diagnostic yield of standard esophageal tests in patients with noncardiac chest pain. Our aim was to assess the diagnostic value of ambulatory 24-hr pH and pressure monitoring in patients with noncardiac chest pain. Stationary manometry, edrophonium testing, and ambulatory pH and motility studies were performed in 90 consecutive patients with recurrent chest pain and normal coronary angiograms. Normality limits of ambulatory 24-hr motility were established in 30 healthy controls. The diagnoses of specific esophageal motility disorders (nutcracker esophagus and diffuse esophageal spasm) by stationary and ambulatory manometry were discordant in 48% of the patients. Edrophonium testing was positive in 9 patients, but correlated poorly with esophageal diagnoses. During ambulatory studies, 144 chest pain events occurred in 42 patients, and 72 (50%) were related to esophageal dysfunction. Strict temporal associations of events with esophageal dysfunction in relation to ambulatory 24-hr pH/motility scores permitted four patient categorizations: true positives (event-related and abnormal tests), N = 15; true negatives (event-unrelated and abnormal tests), N = 10; reduced esophageal pain threshold (event-related and normal tests), N = 4; and indeterminate origin (event-unrelated and normal tests), N = 13. Overall, 19 patients (21%) had a probable esophageal cause for chest pain (14 esophageal motility disorder, 4 acid reflux, 1 both). In conclusion, ambulatory manometry increases the diagnostic yield of standard esophageal testing in noncardiac chest pain, but the gain is small. Causes of chest pain other than high esophageal pressures and acid reflux must still be sought in most patients with chest pain of unknown origin after a negative cardiac work-up.

  9. Remifentanil patient-controlled analgesia for labor – monitoring of newborn heart rate, blood pressure and oxygen saturation during the first 24 hours after delivery

    PubMed Central

    Konefał, Halina; Jaskot, Brygida; Pastuszka, Joanna

    2012-01-01

    Introduction There is no available information about the effects of remifentanil labor analgesia on newborns’ vital signs in the first hours after delivery. The aim of the study was to assess changes in the heart rate, blood pressure and oxygen saturation during the first 24 h of neonatal life after using remifentanil patient-controlled analgesia (PCA) for labor analgesia. Material and methods Forty-four full-term neonates, 23 from intravenous PCA remifentanil labor anesthesia 0.2 µg/kg, repeated not more frequently than every 2 min, and 21 born to mothers without any pharmacological forms of analgesia, were studied. Heart rate, oxygen saturation, and systolic (SBP) and diastolic blood pressure (DBP) were monitored using a Nellcor Oxi Max monitor N5500 (Tyco Healthcare), and recorded at 1 h, 6 h, 12 h and 24 h. Results No significant differences in heart rate (p = 0.54; p = 0.26; p = 0.60; p = 0.83), oxygen saturation (p = 0.21; p = 0.27; p = 0.61; p = 0.9) and DBP (p = 0.98; p = 0.31; p = 0.83; p = 0.58) between the groups at 1 h, 6 h, 12 h and 24 h. Newborns from the remifentanil group had lower SBP at 1 h of life (59 mm Hg vs. 68.5 mm Hg) but the difference was just on the borderline of statistical significance (p > 0.06). There were no significant differences in SBP between the groups at 6 h (p = 0.65), 12 h (p = 0.11), and 24 h (p = 0.89) of life. Conclusions Remifentanil PCA analgesia during labor does not significantly modify the oxygen saturation, heart rate and blood pressure in infants during the first day of their life. Therefore, further studies are needed to explain the observed trend for arterial hypotension in the first hour of life in infants born to mothers treated with remifentanil. PMID:24049531

  10. The 24-Hour Mathematical Modeling Challenge

    ERIC Educational Resources Information Center

    Galluzzo, Benjamin J.; Wendt, Theodore J.

    2015-01-01

    Across the mathematics curriculum there is a renewed emphasis on applications of mathematics and on mathematical modeling. Providing students with modeling experiences beyond the ordinary classroom setting remains a challenge, however. In this article, we describe the 24-hour Mathematical Modeling Challenge, an extracurricular event that exposes…

  11. 24-hour rhythmicity of seizures in refractory focal epilepsy.

    PubMed

    Nzwalo, Hipólito; Menezes Cordeiro, Inês; Santos, Ana Catarina; Peralta, Rita; Paiva, Teresa; Bentes, Carla

    2016-02-01

    The occurrence of seizures in specific types of epilepsies can follow a 24-hour nonuniform or nonrandom pattern. We described the 24-hour pattern of clinical seizures in patients with focal refractory epilepsy who underwent video-electroencephalography monitoring. Only patients who were candidates for epilepsy surgery with an unequivocal seizure focus were included in the study. A total of 544 seizures from 123 consecutive patients were analyzed. Specific time of seizures were distributed along 3- or 4-hour time blocks or bins throughout the 24-hour period. The mean age of the subjects was 37.7 years, with standard deviation of 11.5 years, median of 37. The majority were females (70/56%). The majority of patients had a seizure focus located in the mesial temporal lobe (102/83%) and in the neocortical temporal lobe (13/11%). The remaining patients had a seizure focus located in the extratemporal lobe (8/6%). The most common etiology was mesial temporal sclerosis (86/69.9%). Nonuniform seizure distribution was observed in seizures arising from the temporal lobe (mesial temporal lobe and neocortical temporal lobe), with two peaks found in both 3- and 4-hour bins: 10:00-13:00/16:00-19:00 and 08:00-12:00/16:00-20:00 respectively (p=0.004). No specific 24-hour pattern was identified in seizures from extratemporal location. The 24-hour rhythmicity of seizure distribution is recognized in certain types of epilepsy, but studies on the topic are scarce. Their replication and validation is therefore needed. Our study confirms the bimodal pattern of temporal lobe epilepsy independently of the nature of the lesion. However, peak times differ between different studies, suggesting that the ambient, rhythmic exogenous factors or environmental/social zeitgebers, may modulate the 24-hour rhythmicity of seizures. Characterization of these 24-hour patterns of seizure occurrence can influence diagnosis and treatment in selected types of epilepsy, such as the case of temporal lobe

  12. Effects of verapamil SR and atenolol on 24-hour blood pressure and heart rate in hypertension patients with coronary artery disease: an international verapamil SR-trandolapril ambulatory monitoring substudy.

    PubMed

    Denardo, Scott J; Gong, Yan; Cooper-DeHoff, Rhonda M; Farsang, Csaba; Keltai, Matyas; Szirmai, László; Messerli, Franz H; Bavry, Anthony A; Handberg, Eileen M; Mancia, Giuseppe; Pepine, Carl J

    2015-01-01

    Elevated nighttime blood pressure (BP) and heart rate (HR), increased BP and HR variability, and altered diurnal variations of BP and HR (nighttime dipping and morning surge) in patients with systemic hypertension are each associated with increased adverse cardiovascular events. However, there are no reports on the effect of hypertension treatment on these important hemodynamic parameters in the growing population of hypertensive patients with atherosclerotic coronary artery disease (CAD). This was a pre-specified subgroup analysis of the INternational VErapamil SR-Trandolapril STudy (INVEST), which involved 22,576 clinically stable patients aged ≥ 50 years with hypertension and CAD randomized to either verapamil SR- or atenolol-based hypertension treatment strategies. The subgroup consisted of 117 patients undergoing 24-hour ambulatory monitoring at baseline and after 1 year of treatment. Hourly systolic and diastolic BP (SBP and DBP) decreased after 1 year for both verapamil SR- and atenolol-based treatment strategies compared with baseline (P<0.0001). Atenolol also decreased hourly HR (P<0.0001). Both treatment strategies decreased SBP variability (weighted standard deviation: P = 0.012 and 0.021, respectively). Compared with verapamil SR, atenolol also increased the prevalence of BP and HR nighttime dipping among prior non-dippers (BP: OR = 3.37; 95% CI: 1.26-8.97 P = 0.015; HR: OR = 4.06; 95% CI: 1.35-12.17; P = 0.012) and blunted HR morning surge (+2.8 vs. +4.5 beats/min/hr; P = 0.019). Both verapamil SR- and especially atenolol-based strategies resulted in favorable changes in ambulatory monitoring parameters that have been previously associated with increased adverse cardiovascular events.

  13. A Comparison of Atrial Fibrillation Monitoring Strategies After Cryptogenic Stroke (from the Cryptogenic Stroke and Underlying AF Trial).

    PubMed

    Choe, William C; Passman, Rod S; Brachmann, Johannes; Morillo, Carlos A; Sanna, Tommaso; Bernstein, Richard A; Di Lazzaro, Vincenzo; Diener, Hans-Christoph; Rymer, Marilyn M; Beckers, Frank; Koehler, Jodi; Ziegler, Paul D

    2015-09-15

    Ischemic stroke cause remains undetermined in 30% of cases, leading to a diagnosis of cryptogenic stroke. Paroxysmal atrial fibrillation (AF) is a major cause of ischemic stroke but may go undetected with short periods of ECG monitoring. The Cryptogenic Stroke and Underlying Atrial Fibrillation trial (CRYSTAL AF) demonstrated that long-term electrocardiographic monitoring with insertable cardiac monitors (ICM) is superior to conventional follow-up in detecting AF in the population with cryptogenic stroke. We evaluated the sensitivity and negative predictive value (NPV) of various external monitoring techniques within a cryptogenic stroke cohort. Simulated intermittent monitoring strategies were compared to continuous rhythm monitoring in 168 ICM patients of the CRYSTAL AF trial. Short-term monitoring included a single 24-hour, 48-hour, and 7-day Holter and 21-day and 30-day event recorders. Periodic monitoring consisted of quarterly monitoring through 24-hour, 48-hour, and 7-day Holters and monthly 24-hour Holters. For a single monitoring period, the sensitivity for AF diagnosis was lowest with a 24-hour Holter (1.3%) and highest with a 30-day event recorder (22.8%). The NPV ranged from 82.3% to 85.6% for all single external monitoring strategies. Quarterly monitoring with 24-hour Holters had a sensitivity of 3.1%, whereas quarterly 7-day monitors increased the sensitivity to 20.8%. The NPVs for repetitive periodic monitoring strategies were similar at 82.6% to 85.3%. Long-term continuous monitoring was superior in detecting AF compared to all intermittent monitoring strategies evaluated (p <0.001). Long-term continuous electrocardiographic monitoring with ICMs is significantly more effective than any of the simulated intermittent monitoring strategies for identifying AF in patients with previous cryptogenic stroke.

  14. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Sleeping Time and Certain Other Activities § 785.21 Less than 24-hour duty. An employee who is required to... difference that she is furnished facilities for sleeping. Her time is given to her employer. She is...

  15. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Sleeping Time and Certain Other Activities § 785.21 Less than 24-hour duty. An employee who is required to... difference that she is furnished facilities for sleeping. Her time is given to her employer. She is...

  16. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Sleeping Time and Certain Other Activities § 785.21 Less than 24-hour duty. An employee who is required to... difference that she is furnished facilities for sleeping. Her time is given to her employer. She is...

  17. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Sleeping Time and Certain Other Activities § 785.21 Less than 24-hour duty. An employee who is required to... difference that she is furnished facilities for sleeping. Her time is given to her employer. She is...

  18. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Sleeping Time and Certain Other Activities § 785.21 Less than 24-hour duty. An employee who is required to... difference that she is furnished facilities for sleeping. Her time is given to her employer. She is...

  19. High serum lactate level may predict death within 24 hours

    PubMed Central

    Zoubi, Abd Almajid; Kuria, Shiran; Blum, Nava

    2015-01-01

    Background Unexpected death within 24 hours of admission is a real challenge for the clinician in the emergency room. How to diagnose these patients and the right approach to prevent sudden death with 24 hours is still an enigma. The aims of our study were to find the independent factors that may affect the clinical outcome in the first 24 hours of admission to the hospital. Methods We performed a retrospective study defining unexpected death within 24 hours of admission in our Department of Medicine in the last 6 years. We found 43 patients who died within 24 hours of admission, and compared their clinical and biochemical characteristics to 6055 consecutive patients who were admitted in that period of time and did not die within the first 24 hours of admission. The parameters that were used include gender, age, temperature, clinical and laboratory criteria for SIRS, arterial blood lactate, and arterial blood pH. Results Most of the patients who died within 24 hours had sepsis with SIRS. These patients were older (78.6±14.7 vs. 65.2±20.2 years [p<.0001]), had higher lactate levels (8.0±4.8 vs. 2.1±1.8mmol/L [p<.0001]), and lower pH (7.2±0.2 vs. 7.4±0.1 [p<.0001]). Logistic regression analysis found that lactate was the strongest independent parameter to predict death within 24 hours of admission (OR 1.366 [95% CI 1.235–1.512]), followed by old age (OR 1.048 [95% CI 1.048–1.075] and low arterial blood pH (OR 0.007 [CI <0.001–0.147]). When gender was analyzed, pH was not an independent variable in females (only in males). Conclusions The significant independent variable that predicted death within 24 hours of admission was arterial blood lactate level on admission. Older age was also an independent variable; low pH affected only males, but was a less dominant variable. We suggest use of arterial blood lactate level on admission as a bio-marker in patients with suspected sepsis admitted to the hospital for risk assessment and prediction of death within 24

  20. Preparation and results of a 24-hour orbital flight.

    PubMed

    Titov, G S

    1963-01-01

    The space age presents man with unprecedented opportunities for discovery and for cooperative endeavors to benefit all mankind. My flight of August 6-7, 1961 was conducted for the purpose of determining whether man can stay and work effectively and whether all systems of the spaceship can operate successfully during a period of 24 hours in space. The flight of Vostok II represents an experimental step in a logical sequence which included the first earth orbiting flight of USSR citizen Yuri A. Gagarin. Preparation for the flight included the study of theoretical and applied subjects, testing in various kinds of apparatus which provide acceleration, heat and isolation experience, brief airborne weightless flights and parachute landings, in addition to extensive training in a real spacecraft having simulators for normal and emergency contingencies of space flight. The actual flight was therefore carried out with a sense of confidence and familiarity and with continuous close radio contact with ground centers from whom my fellow cosmonauts served as spokesmen. Sequential boosters totaling 600 000 kg thrust placed the 4731 kg spaceship into a perfect orbit varying in altitude from 178-246 km in a plane 64 degrees 58' inclined to the equator. The spaceship made 17 orbits around the earth landing 25 hours, 18 minutes after take-off. The cabin had full atmospheric pressure and a comfortable habitability which could be extended for 10 days. I was able to maneuver the spaceship and perform many other control functions, make observations and take pictures of the earth and its cloud cover, eat meals and sleep all with good efficiency. I experienced mild symptoms suggestive of seasickness which were aggravated by head turning, ameliorated by sleep and entirely relieved by resumption of g-loading during descent. Altogether analyses of the physical and structural performance of the spaceship and the continuously monitored physiological responses of the pilot indicate that all

  1. The 24 Hours before Hospitalization: Factors Related to Suicide Attempting.

    ERIC Educational Resources Information Center

    Chiles, John A.; And Others

    1986-01-01

    Psychiatric inpatients (N=59) were interviewd concerning psychological and environmental events that occurred in the 24 hours prior to their hospitalization. Suicide attempters were more likely to have used alcohol or marijuana and less likely to have contacted a health care professional than suicide ideators, even when past history of suicide…

  2. Impact of Different Normality Thresholds for 24-hour ABPM at the Primary Health Care Level

    PubMed Central

    Grezzana, Guilherme Brasil; Moraes, David William; Stein, Airton Tetelbon; Pellanda, Lucia Campos

    2017-01-01

    Background Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. Objective To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. Methods A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. Results There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. Conclusion The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. PMID:28099585

  3. Pharmacist-physician co-management of hypertension reduces 24-hour ambulatory blood pressures

    PubMed Central

    Weber, Cynthia A.; Ernst, Michael E.; Sezate, Genesis S.; Zheng, Shimin; Carter, Barry L.

    2010-01-01

    Background Pharmacist-physician co-management of hypertension has been shown to improve office blood pressures (BP). We sought to describe the effect of such a model on 24-hour ambulatory BPs. Methods We performed a prospective, cluster-randomised controlled clinical trial in 179 patients with uncontrolled hypertension from five primary care clinics in Iowa City, Iowa. Patients were randomized by clinic to receive pharmacist-physician collaborative management of hypertension (intervention) or usual care (control) for a 9-month period. In the intervention group, pharmacists helped patients identify barriers to BP control, counselled on lifestyle and dietary modifications, and adjusted antihypertensive therapy in collaboration with the patient’s primary care provider. Patients were seen by pharmacists a minimum every 2 months. Ambulatory BP was obtained at baseline and study end. Results Baseline and end of study ambulatory BP profiles were evaluated for 175 patients. Ambulatory BPs were reduced to a greater extent in the intervention compared to control group (daytime ΔSBP [SD] 15.2[11.5] vs 5.5[13.5], p<0.001; nighttime ΔSBP [SD] 12.2[14.8] vs 3.4[13.3], p<0.001; 24-hour ΔSBP [SD] 14.1[11.3] vs 5.5[12.5], p<0.001). More patients in the intervention group had BP controlled at the end of the study (75% vs 50.7%, p<0.001) as defined by overall 24-hour ambulatory BP monitoring. Conclusions Pharmacist-physician collaborative management of hypertension achieved consistent and significantly greater reduction in 24-hour BP and a high rate of BP control. PMID:20937921

  4. Managing sleep and wakefulness in a 24-hour world.

    PubMed

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work-social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns.

  5. Managing sleep and wakefulness in a 24-hour world

    PubMed Central

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work–social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns. PMID:23957268

  6. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation

    PubMed Central

    Hartley, Geoffrey L.; Zaharieva, Dessi; Basset, Fabien A.; Hynes, Zach

    2016-01-01

    Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (Tc) and cognitive test battery (CTB) performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature). Participants (recruited from those who have regular occupational exposure to cold) were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease Tc after exposure and to eliminate the typical 0.5–1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance. PMID:27478839

  7. [High performance of an implantable Holter monitor in the detection of concealed paroxysmal atrial fibrillation in patients with cryptogenic stroke and a suspected embolic mechanism].

    PubMed

    Rojo-Martinez, Esther; Sandín-Fuentes, María; Calleja-Sanz, Ana I; Cortijo-García, Elisa; García-Bermejo, Pablo; Ruiz-Piñero, Marina; Rubio-Sanz, Jerónimo; Arenillas-Lara, Juan F

    2013-09-16

    Introduccion. El holter implantable permite detectar fibrilacion auricular paroxistica (FAP) oculta en pacientes con ictus criptogenico, pero se desconoce que algoritmo de seleccion tiene un mayor rendimiento y la duracion optima de monitorizacion. Objetivo. Conocer la frecuencia y el tiempo hasta detectar la FAP mediante un holter implantable Reveal XT ® en pacientes con ictus criptogenico seleccionados por sospecha elevada de embolismo cerebral. Pacientes y metodos. Criterios de seleccion: ausencia de etiologia del ictus tras el estudio completo incluyendo un ecocardiograma transesofagico, monitorizacion ECG y holter de 24 horas, asi como confirmacion de oclusion aguda embolica de la arteria intracraneal por duplex transcraneal o bien alta sospecha de embolismo por caracteristicas de neuroimagen. Tras implantar el holter Reveal XT se formo a los pacientes para que emprendieran transmisiones todos los meses o ante sintomas. Se reviso la informacion online mensualmente y se realizaron visitas clinicas en las unidades de Neurologia y Cardiologia. Resultados. Se incluyeron 101 pacientes con ictus criptogenico y al menos un mes de seguimiento: edad media de 67 años, 54 mujeres (53,5%). Tiempo medio de seguimiento: 281 ± 212 dias. Se detecto FAP oculta en 34 pacientes (33,7%) y falsos positivos en 23 (22,8%). Mediana desde el implante hasta la deteccion de la arritmia: 102 dias (rango: 26-240 dias). En un 70% de los pacientes se registraron multiples episodios de FAP. El 75% de los eventos se detectaron durante los primeros seis meses de monitorizacion. Conclusiones. El algoritmo de seleccion de pacientes con ictus criptogenico segun sospecha de embolismo cerebral se asocio a una elevada frecuencia (33,7%) de FAP oculta con holter implantable. Uno de cada cuatro eventos sucedio tras los primeros seis meses de monitorizacion.

  8. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns

    PubMed Central

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  9. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers.

    PubMed

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m(2), had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab(®) device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens(®) algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for "24-hour", "awake", and "asleep" periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects.

  10. New method for assessing cardiac parasympathetic activity using 24 hour electrocardiograms.

    PubMed Central

    Ewing, D J; Neilson, J M; Travis, P

    1984-01-01

    Cardiac parasympathetic activity was assessed using 24 hour electrocardiographic recordings by measuring the incidence of larger changes in successive RR intervals, which in normal subjects occur frequently but irregularly. In 25 normal subjects the mean number of times per hour in which the change in successive RR interval was greater than 50 ms was 150-250 during waking and 350-450 during sleeping. By contrast, 30 diabetics with medically denervated hearts (12 with cardiovascular reflex evidence of parasympathetic damage and 18 with additional sympathetic damage) and six cardiac transplant patients with surgically denervated hearts had extremely low counts. Additionally, of 20 diabetics with normal cardiovascular reflexes, about half had abnormally low counts, suggesting that this method is better than currently available reflex tests in detecting early cardiac parasympathetic damage. This technique provides a valid and sensitive way of monitoring cardiac parasympathetic activity over prolonged periods. PMID:6383446

  11. A 24-hour remote surveillance system for terrestrial wildlife studies

    USGS Publications Warehouse

    Sykes, P.W.; Ryman, W.E.; Kepler, C.B.; Hardy, J.W.

    1995-01-01

    The configuration, components, specifications and costs of a state-of-the-art closed-circuit television system with wide application for wildlife research and management are described. The principal system components consist of color CCTV camera with zoom lens, pan/tilt system, infrared illuminator, heavy duty tripod, coaxial cable, coaxitron system, half-duplex equalizing video/control amplifier, timelapse video cassette recorder, color video monitor, VHS video cassettes, portable generator, fuel tank and power cable. This system was developed and used in a study of Mississippi sandhiIl Crane (Grus canadensis pratensis) behaviors during incubation, hatching and fledging. The main advantages of the system are minimal downtime where a complete record of every event, its time of occurrence and duration, are permanently recorded and can be replayed as many times as necessary thereafter to retrieve the data. The system is particularly applicable for studies of behavior and predation, for counting individuals, or recording difficult to observe activities. The system can be run continuously for several weeks by two people, reducing personnel costs. This paper is intended to provide biologists who have litte knowledge of electronics with a system that might be useful to their specific needs. The disadvantages of this system are the initial costs (about $9800 basic, 1990-1991 U.S. dollars) and the time required to playback video cassette tapes for data retrieval, but the playback can be sped up when litte or no activity of interest is taking place. In our study, the positive aspects of the system far outweighed the negative.

  12. Low correlation between visit-to-visit variability and 24-hour variability of blood pressure

    PubMed Central

    Muntner, Paul; Shimbo, Daichi; Diaz, Keith M.; Newman, Jonathan; Sloan, Richard P.; Schwartz, Joseph E.

    2013-01-01

    Visit-to-visit variability (VVV) of clinic systolic blood pressure (SBP) has been associated with cardiovascular disease risk. Given the need for obtaining blood pressure (BP) at multiple visits to calculate VVV, substituting BP variability from ambulatory blood pressure monitoring (ABPM) may be a practical alternative. We assessed the correlation between VVV of BP and BP variability from ABPM using data from 146 untreated, mostly normotensive participants (mean age 47.9 years) in a substudy of the ongoing Masked Hypertension Study. VVV of SBP and diastolic blood pressure (DBP) was estimated by the standard deviation (SDvvv) and average real variability (ARVvvv) from 6 study visits over a median of 216 days. ABPM data were used to calculate the day-night SD (SDdn) and the ARV of SBP and DBP over 24 hours (ARV24). For SBP, the mean SDvvv and SDdn were 6.3 (SD=2.5) and 8.8 (SD=1.8) mmHg, respectively, and mean ARVvvv and ARV24 were 7.2 (SD=3.2) and 8.4 (SD=2.1) mmHg, respectively. The Spearman correlation coefficient between SDvvv and SDdn of SBP was rs=0.25 and between ARVvvv and ARV24 was rs=0.17. Participants in the highest quartile of SDdn of SBP were 1.66 (95% CI: 0.93 – 2.75) times more likely to be in the highest quartile of SDvvv of SBP. The observed-to-expected ratio between the highest quartiles of ARVvvv and ARV24 of SBP was 0.89 (95% CI: 0.41 – 1.69). The correlations for SDvvv and SDdn and ARVvvv and ARV24 of DBP were minimal. These data suggest VVV and 24-hour variability are weakly correlated and not interchangeable. PMID:23784506

  13. Effects of exenatide and liraglutide on 24-hour glucose fluctuations in type 2 diabetes.

    PubMed

    Nagakura, Jo; Yamakawa, Tadashi; Taguri, Masataka; Tsuchiya, Hirohisa; Shigematsu, Erina; Suzuki, Jun; Morita, Satoshi; Kadonosono, Kazuaki; Terauchi, Yasuo

    2016-01-01

    We evaluated the influence of short-term treatment with exenatide twice daily or liraglutide once daily on daily blood glucose fluctuations in 40 patients with type 2 diabetes inadequately controlled by sulfonylureas. The patients in a multicenter, open-label trial were randomly assigned to receive add-on exenatide (10 μg/day, n = 21) or add-on liraglutide (0.3-0.9 mg/day, n = 19), and underwent 24-hour continuous subcutaneous glucose monitoring. There was no significant between-group difference in glucose fluctuations during the day, as assessed by calculating mean amplitude of glycemic excursion (MAGE) and standard deviation (SD). However, the mean blood glucose levels at 3 hours after breakfast and dinner were significantly lower in the exenatide group than the liraglutide group (breakfast: 127.3 ± 24.1 vs. 153.4 ± 28.7 mg/dL; p = 0.006, dinner: 108.7 ± 17.3 vs. 141.9 ± 24.2 mg/dL; p < 0.001). In contrast, mean blood glucose levels and their SD were significantly lower between 0000 h and 0600 h in the liraglutide group than the exenatide group (average glucose: 126.9 ± 27.1 vs. 107.1 ± 24.0 mg/dL; p = 0.029, SD: 15.2 ± 10.5 vs. 8.7 ± 3.8; p = 0.020). Both groups had similar glucose fluctuations despite differences in 24-hour blood glucose profiles. Therefore, each of these agents may have advantages or disadvantages and should be selected according to the blood glucose profile of the patient.

  14. A comparison of overnight and 24 hour collection to measure urinary catecholamines.

    PubMed

    White, I R; Brunner, E J; Barron, J L

    1995-02-01

    The period of urine collection used to measure excretion of catecholamines varies in epidemiological practice. We set out to compare overnight with 24 hour collection. Twenty-four subjects each collected urine for 24 hours, with the overnight urine being separately collected. The correlation of overnight and 24 hour catecholamines was highest when both measures were standardised for creatinine excretion and when creatinine excretion was adjusted for urine flow rate. The observed correlations were 0.74 for dopamine, 0.81 for noradrenaline and 0.54 for adrenaline. The use of overnight collections may therefore require a sample size up to 1.5 times as large (for noradrenaline) or 3.4 times as large (for adrenaline) to achieve the same power as with 24 hour collections. However, the figures given exaggerate the advantage of 24 hour collections if these incorporate measurement errors that are not present in overnight collections.

  15. Optimal dose of oral omeprazole for maximal 24 hour decrease of intragastric acidity.

    PubMed Central

    Sharma, B K; Walt, R P; Pounder, R E; Gomes, M D; Wood, E C; Logan, L H

    1984-01-01

    In a series of 59 experiments in nine duodenal ulcer patients, 24 hour intragastric acidity was measured before, during, and after treatment with daily oral omeprazole. Omeprazole 10, 20, and 30 mg/day for one week caused a 37, 90, and 97% decrease of 24 hour intragastric acidity, respectively. No further decrease of acidity was observed when the dose of omeprazole was doubled to 60 mg/day, or after a second week of treatment with 30 mg/day. One week after stopping treatment with omeprazole (14 doses) there was a significant 26% decrease of 24 hour intragastric acidity, with full recovery seven weeks later. Fasting plasma gastrin concentration was significantly raised during treatment with all doses of omeprazole. Omeprazole 30 mg/day is the optimal dose for a maximal decrease of 24 hour intragastric acidity in duodenal ulcer patients. PMID:6469081

  16. Comparison of anthropometric and training characteristics between recreational male marathoners and 24-hour ultramarathoners

    PubMed Central

    Rüst, Christoph Alexander; Knechtle, Beat; Knechtle, Patrizia; Rosemann, Thomas

    2012-01-01

    Background Of the anthropometry and training variables used to predict race performance in a 24-hour ultrarun, the personal best marathon time is the strongest predictor in recreational male 24-hour ultramarathoners. This finding raises the question of whether similarities exist between male recreational 24-hour ultramarathoners and male recreational marathoners. Methods The association between age, anthropometric variables (ie, body mass, body height, body mass index, percent body fat, skeletal muscle mass, limb circumference, and skinfold thickness at the pectoral, mid axillary, triceps, subscapular, abdominal, suprailiac, front thigh, and medial calf sites), previous experience and training characteristics (ie, volume, speed, and personal best time), and race time for 79 male recreational 24-hour ultramarathoners and 126 male recreational marathoners was investigated using bivariate and multivariate analysis. Results The 24-hour ultramarathoners were older (P < 0.05), had a lower circumference at both the upper arm (P < 0.05) and thigh (P < 0.01), and a lower skinfold thickness at the pectoral, axillary, and suprailiac sites (P < 0.05) compared with the marathoners. During training, the 24-hour ultramarathoners were running for more hours per week (P < 0.001) and completed more kilometers (P < 0.001), but were running slower (P < 0.01) compared with the marathoners. In the 24-hour ultramarathoners, neither anthropometric nor training variables were associated with kilometers completed in the race (P > 0.05). In the marathoners, percent body fat (P < 0.001) and running speed during training (P < 0.0001) were related to marathon race times. Conclusion In summary, differences in anthropometric and training predictor variables do exist between male recreational 24-hour ultramarathoners and male recreational marathoners for race performance. PMID:24198595

  17. Insights about serum sodium behavior after 24 hours of continuous renal replacement therapy

    PubMed Central

    Romano, Thiago Gomes; Martins, Cassia Pimenta Barufi; Mendes, Pedro Vitale; Besen, Bruno Adler Maccagnan Pinheiro; Zampieri, Fernando Godinho; Park, Marcelo

    2016-01-01

    Objective The aim of this study was to investigate the clinical and laboratorial factors associated with serum sodium variation during continuous renal replacement therapy and to assess whether the perfect admixture formula could predict 24-hour sodium variation. Methods Thirty-six continuous renal replacement therapy sessions of 33 patients, in which the affluent prescription was unchanged during the first 24 hours, were retrieved from a prospective collected database and then analyzed. A mixed linear model was performed to investigate the factors associated with large serum sodium variations (≥ 8mEq/L), and a Bland-Altman plot was generated to assess the agreement between the predicted and observed variations. Results In continuous renal replacement therapy 24-hour sessions, SAPS 3 (p = 0.022) and baseline hypernatremia (p = 0.023) were statistically significant predictors of serum sodium variations ≥ 8mEq/L in univariate analysis, but only hypernatremia demonstrated an independent association (β = 0.429, p < 0.001). The perfect admixture formula for sodium prediction at 24 hours demonstrated poor agreement with the observed values. Conclusions Hypernatremia at the time of continuous renal replacement therapy initiation is an important factor associated with clinically significant serum sodium variation. The use of 4% citrate or acid citrate dextrose - formula A 2.2% as anticoagulants was not associated with higher serum sodium variations. A mathematical prediction for the serum sodium concentration after 24 hours was not feasible. PMID:27410407

  18. Agreement between 24-hour salt ingestion and sodium excretion in a controlled environment.

    PubMed

    Lerchl, Kathrin; Rakova, Natalia; Dahlmann, Anke; Rauh, Manfred; Goller, Ulrike; Basner, Mathias; Dinges, David F; Beck, Luis; Agureev, Alexander; Larina, Irina; Baranov, Victor; Morukov, Boris; Eckardt, Kai-Uwe; Vassilieva, Galina; Wabel, Peter; Vienken, Jörg; Kirsch, Karl; Johannes, Bernd; Krannich, Alexander; Luft, Friedrich C; Titze, Jens

    2015-10-01

    Accurately collected 24-hour urine collections are presumed to be valid for estimating salt intake in individuals. We performed 2 independent ultralong-term salt balance studies lasting 105 (4 men) and 205 (6 men) days in 10 men simulating a flight to Mars. We controlled dietary intake of all constituents for months at salt intakes of 12, 9, and 6 g/d and collected all urine. The subjects' daily menus consisted of 27 279 individual servings, of which 83.0% were completely consumed, 16.5% completely rejected, and 0.5% incompletely consumed. Urinary recovery of dietary salt was 92% of recorded intake, indicating long-term steady-state sodium balance in both studies. Even at fixed salt intake, 24-hour urine collection for sodium excretion (UNaV) showed infradian rhythmicity. We defined a ±25 mmol deviation from the average difference between recorded sodium intake and UNaV as the prediction interval to accurately classify a 3-g difference in salt intake. Because of the biological variability in UNaV, only every other daily urine sample correctly classified a 3-g difference in salt intake (49%). By increasing the observations to 3 consecutive 24-hour collections and sodium intakes, classification accuracy improved to 75%. Collecting seven 24-hour urines and sodium intake samples improved classification accuracy to 92%. We conclude that single 24-hour urine collections at intakes ranging from 6 to 12 g salt per day were not suitable to detect a 3-g difference in individual salt intake. Repeated measurements of 24-hour UNaV improve precision. This knowledge could be relevant to patient care and the conduct of intervention trials.

  19. Asymptomatic rhythm and conduction abnormalities in children with acute rheumatic fever: 24-hour electrocardiography study.

    PubMed

    Karacan, Mehmet; Işıkay, Sedat; Olgun, Haşim; Ceviz, Naci

    2010-12-01

    Some rhythm and conduction abnormalities can occur in children with acute rheumatic fever. These abnormalities have been defined based on standard electrocardiography; however, the real prevalence of these abnormalities has not been investigated previously by the evaluation of long-term electrocardiographic recordings. In this study, we evaluated the asymptomatic rhythm and conduction abnormalities in children with acute rheumatic fever by evaluating the 24-hour electrocardiography. We evaluated the standard electrocardiography and the 24-hour electrocardiography of 64 children with acute rheumatic fever. On standard electrocardiography, the frequency of the first-degree atrioventricular block was found to be 21.9%. Electrocardiography at 24 hours detected three additional and separate patients with a long PR interval. Mobitz type I block and atypical Wenckebach periodicity were determined in one patient (1.56%) on 24-hour electrocardiography. While accelerated junctional rhythm was detected in three patients on standard electrocardiography, it was present in nine patients according to 24-hour electrocardiography. Premature contractions were present in 1.7% of standard electrocardiography, but in 29.7% of 24-hour electrocardiography. Absence of carditis was found to be related to the presence of accelerated junctional rhythm (p > 0.05), and the presence of carditis was found to be related to the presence of premature contractions (p = 0.000). In conclusion, our results suggest that in children with acute rheumatic fever, the prevalence of rhythm and conduction abnormalities may be much higher than determined on standard electrocardiography. Further studies are needed to clarify whether or not these abnormalities are specific to acute rheumatic fever.

  20. Ventricular premature beats on Holter monitoring in patients admitted with chest pain, in whom acute myocardial infarction is not confirmed. The prognostic value and relationship to scars or ischemia on thallium-201 scintigraphy

    SciTech Connect

    Madsen, J.K.; Sorensen, J.N.; Kromann-Andersen, B.; Kjeldgaard, K.M.; Christoffersen, K.; van Duijvendijk, K.; Reiber, J.H.

    1987-05-01

    Ambulatory 24-h Holter monitoring was carried out in 198 patients who had been admitted because of suspected acute myocardial infarction (AMI) due to chest pain, but in whom AMI was not confirmed. During a follow-up period of 12-24 months (median 14 months) 16 cardiac events (i.e., nonfatal AMI or cardiac death) occurred. Ventricular premature beats (VPBs) were found in 65.2% of the patients, complex VPBs in 28.8%. Pairs of VPBs which were seen in 10.0% of the patients were the only important type of VPBs significantly related to an impaired prognosis. Thallium-201 scintigraphy was performed in 144 of the patients. VPBs were significantly related to scar formation (i.e., to permanent defects, but not to ischemia, specifically, to transient defects). It is concluded that ventricular arrhythmias in this patient category indicate presence of chronic ischemic heart disease, and that pairs of VPBs seem to identify patients at risk for cardiac events.

  1. Continual 24-hour observations of thermospheric winds made with the SOFDI instrument from Huancayo, Peru

    NASA Astrophysics Data System (ADS)

    Gerrard, Andrew; Meriwether, John W.

    The Second generation Optimized Fabry-Perot Doppler Imager (SOFDI), a state-of-the-art triple-etalon Fabry-Perot interferometer, has been sucessfully relocated to Huancayo, Peru and is making continual 24-hour observations. The 630-nm data, originating from layer-integrated OI emission with centroid heights of 250 km at night and 220 km during the day, are analyzed so as to obtain measurements of horizontal winds in the thermosphere. In this paper we report the most recent results from continuous 24-hour observations of these thermospheric parameters.

  2. Aldosterone-to-Renin Ratio Is Associated With Reduced 24-Hour Heart Rate Variability and QTc Prolongation in Hypertensive Patients.

    PubMed

    Grübler, Martin R; Kienreich, Katharina; Gaksch, Martin; Verheyen, Nicolas; Hartaigh, Bríain Ó; Fahrleitner-Pammer, Astrid; März, Winfried; Schmid, Johannes; Oberreither, Eva-Maria; Wetzel, Julia; Catena, Cristiana; Sechi, Leonardo A; Pieske, Burkert; Tomaschitz, Andreas; Pilz, Stefan

    2016-02-01

    Aldosterone is considered to exert direct effects on the myocardium and the sympathetic nervous system. Both QT time and heart rate (HR) variability (HRV) are considered to be markers of arrhythmic risk and autonomous dysregulation. In this study, we investigated the associations between aldosterone, QT time, and HRV in patients with arterial hypertension.We recruited 477 hypertensive patients (age: 60.2 ± 10.2 years; 52.3% females) with a mean systolic/diastolic 24-hour ambulatory blood pressure monitoring (ABPM) value of 128 ± 12.8/77.1 ± 9.2 mmHg and with a median of 2 (IQR: 1-3) antihypertensive agents. Patients were recruited from the outpatient clinic at the Department of Internal Medicine of the Medical University of Graz, Austria. Blood samples, 24-hour HRV derived from 24-hour blood pressure monitoring (ABPM) and ECG's were obtained. Plasma aldosterone and plasma renin concentrations were measured by means of a radioimmunoassay. Twenty-four-hour urine specimens were collected in parallel with ABPM.Mean QTc was 423.3 ± 42.0 milliseconds for males and 434.7 ± 38.3 milliseconds for females. Mean 24H-HR and 24H-HRV was 71.9 ± 9.8 and 10.0 ± 3.6 bpm, respectively. In linear regression analyses adjusted for age, sex, body mass index, ABPM, and current medication, aldosterone to active renin ratio (AARR) was significantly associated with the QTc interval, a marker for cardiac repolarization abnormalities (mean = 426 ± 42.4 milliseconds; β-coefficient = 0.121; P = 0.03) as well as with the 24-hour heart rate variability a surrogate for autonomic dysfunction (median = 9.67 [IQR = 7.38-12.22 bpm]; β-coefficient = -0.133; P = 0.01).In hypertensive patients, AARR is significantly related to QTc prolongation as well as HRV. Further studies investigating the effects of mineralocorticoid receptor blocker and aldosterone synthase inhibitors on QTc and HRV are warranted.

  3. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Sleeping Time and Certain Other Activities § 785.22 Duty of 24 hours or more. (a) General. Where an... bona fide meal periods and a bona fide regularly scheduled sleeping period of not more than 8 hours from hours worked, provided adequate sleeping facilities are furnished by the employer and the...

  4. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Sleeping Time and Certain Other Activities § 785.22 Duty of 24 hours or more. (a) General. Where an... bona fide meal periods and a bona fide regularly scheduled sleeping period of not more than 8 hours from hours worked, provided adequate sleeping facilities are furnished by the employer and the...

  5. 24-Hour Access: Responding to Students' Need for Late Library Hours at the University of Denver

    ERIC Educational Resources Information Center

    Sewell, Bethany B.

    2013-01-01

    The University of Denver's Penrose Library saw a substantial increase in use as a result of several new and enhanced services over a six-year period. In turn, longer operating hours and increased staffing for a 24-hours-a-day, five-days-a-week (24 x 5) operating schedule was funded. This case study analyzes student need for longer library hours…

  6. Assessing dietary intake in childhood cancer survivors: Food frequency questionnaire versus 24-hour diet recalls

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet r...

  7. Mood-Dependent Cognitive Change in a Man with Bipolar Disorder Who Cycles Every 24 Hours

    ERIC Educational Resources Information Center

    Lam, Dominic; Mansell, Warren

    2008-01-01

    A case study of a bipolar patient whose mood changes every 24 hours is described to illustrate the changes in cognitive processing and content during different phases of bipolar disorder. The participant completed a battery of questionnaires and tasks on 4 separate occasions: twice when depressed and twice when manic. Depression tended to be…

  8. The Three-Continent, 24-Hour Help Desk: An Academic First?

    ERIC Educational Resources Information Center

    Sykes, Jean

    2002-01-01

    Describes Follow the Sun, a computer help-desk service that takes advantage of time differences around the world to permit four universities (University of Colorado Boulder, Australia's Macquarie and Newcastle universities, and the London School of Economics) to share services and provide 24-hour support to users. (EV)

  9. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Sleeping Time and Certain Other Activities § 785.22 Duty of 24 hours or more. (a) General. Where an... bona fide meal periods and a bona fide regularly scheduled sleeping period of not more than 8 hours from hours worked, provided adequate sleeping facilities are furnished by the employer and the...

  10. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Sleeping Time and Certain Other Activities § 785.22 Duty of 24 hours or more. (a) General. Where an... bona fide meal periods and a bona fide regularly scheduled sleeping period of not more than 8 hours from hours worked, provided adequate sleeping facilities are furnished by the employer and the...

  11. 29 CFR 785.22 - Duty of 24 hours or more.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Sleeping Time and Certain Other Activities § 785.22 Duty of 24 hours or more. (a) General. Where an... bona fide meal periods and a bona fide regularly scheduled sleeping period of not more than 8 hours from hours worked, provided adequate sleeping facilities are furnished by the employer and the...

  12. 24 Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices

    PubMed Central

    Rosenberger, Mary E.; Buman, Matthew P.; Haskell, William L.; McConnell, Michael V.; Carstensen, Laura L.

    2015-01-01

    Getting enough sleep, exercising and limiting sedentary activities can greatly contribute to disease prevention and overall health and longevity. Measuring the full 24-hour activity cycle - sleep, sedentary behavior (SED), light intensity physical activity (LPA) and moderate-to-vigorous physical activity (MVPA) - may now be feasible using small wearable devices. PURPOSE This study compares nine devices for accuracy in 24-hour activity measurement. METHODS Adults (N=40, 47% male) wore nine devices for 24-hours: Actigraph GT3X+, activPAL, Fitbit One, GENEactiv, Jawbone Up, LUMOback, Nike Fuelband, Omron pedometer, and Z-Machine. Comparisons (to standards) were made for total sleep time (Z-machine), time spent in SED (activPAL), LPA (GT3x+), MVPA (GT3x+), and steps (Omron). Analysis included mean absolute percent error, equivalence testing, and Bland-Altman plots. RESULTS Error rates ranged from 8.1–16.9% for sleep; 9.5–65.8% for SED; 19.7–28.0% for LPA; 51.8–92% for MVPA; and 14.1–29.9% for steps. Equivalence testing indicated only two comparisons were significantly equivalent to standards: the LUMOback for sedentary behavior and the GT3X+ for sleep. Bland-Altman plots indicated GT3X+ had the closest measurement for sleep, LUMOback for sedentary behavior, GENEactiv for LPA, Fitbit for MVPA and GT3X+ for steps. CONCLUSIONS Currently, no device accurately captures activity data across the entire 24-hour day, but the future of activity measurement should aim for accurate 24-hour measurement as a goal. Researchers should continue to select measurement devices based on their primary outcomes of interest. PMID:26484953

  13. Seasonal changes of 24-hour intraocular pressure rhythm in healthy Shanghai population

    PubMed Central

    Cheng, Jingyi; Xiao, Ming; Xu, Huan; Fang, Shaobin; Chen, Xu; Kong, Xiangmei; Sun, Xinghuai

    2016-01-01

    Abstract The aim of the present study was to investigate and compare the 24-hour intraocular pressure (IOP) rhythms in winter and summer in the healthy population of Shanghai, China. This is a cross-sectional study in which 24-hour IOP measurements were taken for all eligible healthy volunteers in winter and summer, respectively, and the temperature, hours of sunlight (sunlight time), and circulatory parameters, including heart rate, systolic blood pressure, and diastolic blood pressure, were also recorded. The 24-hour IOP curves and IOP parameters (mean, peak, trough, and fluctuation of IOP together with the diurnal-to-nocturnal IOP change) in winter and summer were obtained and compared. The magnitude of IOP changes from summer to winter was also calculated. A total of 29 participants (58 eyes), 14 (48.28%) male and 15 (51.72%) female, aged 43.66 ± 12.20 (19–61) years, were considered eligible for this study. Generally, IOP decreased progressively before noon, increased notably in the nocturnal period, and peaked at 12:00 am in winter and at 2:00 am in summer. The pattern of 24-hour IOP in winter and summer was significantly different (P = 0.002). The average IOPs from 4:00 pm to 8:00 am, except for 6:00 am, were significantly higher in winter (P < 0.05). However, no significant differences were shown after adjusting for temperature and/or sunlight time. From summer to winter, the extent of IOP increase was mostly around 0 to 3 mm Hg, and the IOPs increased more significantly in the nocturnal period than in the diurnal period (P = 0.05). The 24-hour IOP rhythms were different in winter and summer, with higher IOP level in winter. Temperature and sunlight time, which are independent of heart rate and blood pressure, affected the 24-hour IOP rhythms in healthy people in Shanghai, China. Further investigations are expected for the rhythm of some endogenous substance secretion and the inner mechanism of regulation of IOP. PMID:27495076

  14. Experiences of 24-hour advice line services: a framework for good practice and meeting NICE guidelines.

    PubMed

    Yardley, Sarah J; Codling, Jan; Roberts, Dai; O Donnell, Valerie; Taylor, Sue

    2009-06-01

    This article presents a framework for the practical implementation of a 24-hour specialist palliative care advice line, illustrated by two case examples from the authors' experience. In the UK, National Institute for Health and Clinical Excellence guidance requires provision of 24-hour access to specialist palliative care advice for healthcare professionals and carers regardless of a patient's location. Effective implementation of a telephone advice line for specialist advice is one approach to addressing the current variability in palliative care service provision, both in the UK and elsewhere. The authors were unable to identify a model with documentation for ensuring adequate clinical governance of an advice line in the literature and so present their own. The accompanying case examples demonstrate the difference between 'evolution of services by demand' and taking a systemic approach to service design. Key recommendations for practice are outlined for an effective advice line service which incorporates training and education into the clinical governance structures of the host organization.

  15. Exercising in the Fasted State Reduced 24-Hour Energy Intake in Active Male Adults

    PubMed Central

    Deitrick, Ronald W.; Hillman, Angela R.

    2016-01-01

    The effect of fasting prior to morning exercise on 24-hour energy intake was examined using a randomized, counterbalanced design. Participants (12 active, white males, 20.8 ± 3.0 years old, VO2max: 59.1 ± 5.7 mL/kg/min) fasted (NoBK) or received breakfast (BK) and then ran for 60 minutes at 60%  VO2max. All food was weighed and measured for 24 hours. Measures of blood glucose and hunger were collected at 5 time points. Respiratory quotient (RQ) was measured during exercise. Generalized linear mixed models and paired sample t-tests examined differences between the conditions. Total 24-hour (BK: 19172 ± 4542 kJ versus NoBK: 15312 ± 4513 kJ; p < 0.001) and evening (BK: 12265 ± 4278 kJ versus NoBK: 10833 ± 4065; p = 0.039) energy intake and RQ (BK: 0.90 ± 0.03 versus NoBK: 0.86 ± 0.03; p < 0.001) were significantly higher in BK than NoBK. Blood glucose was significantly higher in BK than NoBK before exercise (5.2 ± 0.7 versus 4.5 ± 0.6 mmol/L; p = 0.025). Hunger was significantly lower for BK than NoBK before exercise, after exercise, and before lunch. Blood glucose and hunger were not associated with energy intake. Fasting before morning exercise decreased 24-hour energy intake and increased fat oxidation during exercise. Completing exercise in the morning in the fasted state may have implications for weight management. PMID:27738523

  16. Circadian polymorphisms in night owls, in bipolars, and in non-24-hour sleep cycles.

    PubMed

    Kripke, Daniel F; Klimecki, Walter T; Nievergelt, Caroline M; Rex, Katharine M; Murray, Sarah S; Shekhtman, Tatyana; Tranah, Gregory J; Loving, Richard T; Lee, Heon-Jeong; Rhee, Min Kyu; Shadan, Farhad F; Poceta, J Steven; Jamil, Shazia M; Kline, Lawrence E; Kelsoe, John R

    2014-10-01

    People called night owls habitually have late bedtimes and late times of arising, sometimes suffering a heritable circadian disturbance called delayed sleep phase syndrome (DSPS). Those with DSPS, those with more severe progressively-late non-24-hour sleep-wake cycles, and those with bipolar disorder may share genetic tendencies for slowed or delayed circadian cycles. We searched for polymorphisms associated with DSPS in a case-control study of DSPS research participants and a separate study of Sleep Center patients undergoing polysomnography. In 45 participants, we resequenced portions of 15 circadian genes to identify unknown polymorphisms that might be associated with DSPS, non-24-hour rhythms, or bipolar comorbidities. We then genotyped single nucleotide polymorphisms (SNPs) in both larger samples, using Illumina Golden Gate assays. Associations of SNPs with the DSPS phenotype and with the morningness-eveningness parametric phenotype were computed for both samples, then combined for meta-analyses. Delayed sleep and "eveningness" were inversely associated with loci in circadian genes NFIL3 (rs2482705) and RORC (rs3828057). A group of haplotypes overlapping BHLHE40 was associated with non-24-hour sleep-wake cycles, and less robustly, with delayed sleep and bipolar disorder (e.g., rs34883305, rs34870629, rs74439275, and rs3750275 were associated with n=37, p=4.58E-09, Bonferroni p=2.95E-06). Bright light and melatonin can palliate circadian disorders, and genetics may clarify the underlying circadian photoperiodic mechanisms. After further replication and identification of the causal polymorphisms, these findings may point to future treatments for DSPS, non-24-hour rhythms, and possibly bipolar disorder or depression.

  17. Iodine Excretion in 24-hour Urine Collection and Its Dietary Determinants in Healthy Japanese Adults

    PubMed Central

    Katagiri, Ryoko; Asakura, Keiko; Uechi, Ken; Masayasu, Shizuko; Sasaki, Satoshi

    2016-01-01

    Background Since seaweed is a common component of the Japanese diet, iodine intake in Japanese is expected to be high. However, urinary iodine excretion, measured using 24-hour urine samples, and its dietary determinants are not known. Methods Apparently healthy adults aged 20 to 69 years living in 20 areas throughout Japan were recruited in February and March, 2013. Urinary iodine excretion was evaluated using 24-hour urine collected from 713 subjects (362 men and 351 women), and the difference among age groups was assessed. The association between dietary intake of food groups and urinary iodine excretion was assessed among 358 subjects who completed a semi-weighed 4-day diet record (DR) and urine collection. The correlations between iodine intake and iodine excretion were also evaluated, and correlation coefficients were calculated for iodine intake in the DR of the overlapping day or the DR 1 day before and after urine collection. Results Median iodine excretion in 24-hour urine was 365 µg, and excretion was significantly higher in older subjects. Iodine intake estimated by the DRs was significantly correlated with urinary iodine excretion when DRs and urine collection were obtained on the same day (r = 0.37). After adjustment for confounding factors, iodine excretion was significantly associated with intakes of kelp and soup stock from kelp and fish. Conclusions Although multiple measurements for urinary iodine are required to confirm our results, this study showed the current iodine status of healthy Japanese adults. The results suggest that kelp and fish are the main contributors to Japanese iodine status measured by 24-hour urine. PMID:27374137

  18. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice

    PubMed Central

    Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-01-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders. PMID:27609090

  19. [24-hour energy metabolism in the human: circadian rhythm, relation to body weight and nutrition].

    PubMed

    Steiniger, J

    1985-04-15

    In 7 men with normal weight and 9 man with overweight and healthy metabolism the resting and fasting energy expenditure was indirectly calorimetrically pursued in the open system over 24 hours. The total energy expenditure over 24 hours revealed an ascertained dependence on body-weight and nutrition. The persons with overweight had a higher absolute energy expenditure, however, the activity of the energy metabolism of the body mass free from fat and the active body mass, respectively, decreased with increasing overweight. The resting and fasting energy expenditure showed in all measured parameters (oxygen consumption, respiratory quotient and nitrogen excretion in the urine) an ascertained daily periodicity (circadian rhythm), which was widely independent of body weight. Only the average daily level C0 (rhythm adjusted level) of the resting and fasting energy expenditure was positively correlated with the body weight and the food energy intake. A negative energy balance (reduction 1.2 MJ/d over 28 days) influenced only the total energy and substrate balance over 24 hours and the daily average level, respectively. The circadian conditions remained unchanged (Chossat's phenomenon). The variability in daily rhythm of the energy expenditure of nearly 25% of the daily average should be taken into consideration in the judgment of exogenically stimulated changes in the energy metabolism.

  20. Validation of triple pass 24-hour dietary recall in Ugandan children by simultaneous weighed food assessment

    PubMed Central

    Olupot-Olupot, Peter; Engoru, Charles; Ssenyondo, Tonny; Nteziyaremye, Julius; Amorut, Denis; Nakuya, Margaret; Arimi, Margaret; Frost, Gary; Maitland, Kathryn

    2016-01-01

    Background Undernutrition remains highly prevalent in African children, highlighting the need for accurately assessing dietary intake. In order to do so, the assessment method must be validated in the target population. A triple pass 24 hour dietary recall with volumetric portion size estimation has been described but not previously validated in African children. This study aimed to establish the relative validity of 24-hour dietary recalls of daily food consumption in healthy African children living in Mbale and Soroti, eastern Uganda compared to simultaneous weighed food records. Methods Quantitative assessment of daily food consumption by weighed food records followed by two independent assessments using triple pass 24-hour dietary recall on the following day. In conjunction with household measures and standard food sizes, volumes of liquid, dry rice, or play dough were used to aid portion size estimation. Inter-assessor agreement, and agreement with weighed food records was conducted primarily by Bland-Altman analysis and secondly by intraclass correlation coefficients and quartile cross-classification. Results 19 healthy children aged 6 months to 12 years were included in the study. Bland-Altman analysis showed 24-hour recall only marginally under-estimated energy (mean difference of 149kJ or 2.8%; limits of agreement -1618 to 1321kJ), protein (2.9g or 9.4%; -12.6 to 6.7g), and iron (0.43mg or 8.3%; -3.1 to 2.3mg). Quartile cross-classification was correct in 79% of cases for energy intake, and 89% for both protein and iron. The intraclass correlation coefficient between the separate dietary recalls for energy was 0.801 (95% CI, 0.429-0.933), indicating acceptable inter-observer agreement. Conclusions Dietary assessment using 24-hour dietary recall with volumetric portion size estimation resulted in similar and acceptable estimates of dietary intake compared with weighed food records and thus is considered a valid method for daily dietary intake assessment of

  1. Static stretching can impair explosive performance for at least 24 hours.

    PubMed

    Haddad, Monoem; Dridi, Amir; Chtara, Moktar; Chaouachi, Anis; Wong, Del P; Behm, David; Chamari, Karim

    2014-01-01

    The aim of this study was to compare the effects of static vs. dynamic stretching (DS) on explosive performances and repeated sprint ability (RSA) after a 24-hour delay. Sixteen young male soccer players performed 15 minutes of static stretching (SS), DS, or a no-stretch control condition (CC) 24 hours before performing explosive performances and RSA tests. This was a within-subject repeated measures study with SS, DS, and CC being counterbalanced. Stretching protocols included 2 sets of 7 minutes 30 seconds (2 repetitions of 30 seconds with a 15-second passive recovery) for 5 muscle groups (quadriceps, hamstring, calves, adductors, and hip flexors). Twenty-four hours later (without any kind of stretching in warm-up), the players were tested for the 30-m sprint test (with 10- and 20-m lap times), 5 jump test (5JT), and RSA test. Significant differences were observed between CC, SS, and DS with 5JT (F = 9.99, p < 0.00, effect size [ES] = 0.40), 10-m sprint time (F = 46.52, p < 0.00, ES = 0.76), 20-m sprint time (F = 18.44, p < 0.000, ES = 0.55), and 30-m sprint time (F = 34.25, p < 0.000, ES = 0.70). The significantly better performance (p < 0.05) was observed after DS as compared with that after CC and SS in 5JT, and sprint times for 10, 20, and 30 m. In contrast, significantly worse performance (p < 0.05) was observed after SS as compared with that after CC in 5JT, and sprint times for 10, 20, and 30 m. With RSA, no significant difference was observed between different stretching protocols in the total time (F = 1.55, p > 0.05), average time (F = 1.53, p > 0.05), and fastest time (F = 2.30, p > 0.05), except for the decline index (F = 3.54, p < 0.04, ES = 0.19). Therefore, the SS of the lower limbs and hip muscles had a negative effect on explosive performances up to 24 hours poststretching with no major effects on the RSA. Conversely, the DS of the same muscle groups are highly recommended 24 hours before performing sprint and long-jump performances. In

  2. Treating allergic conjunctivitis: A once-daily medication that provides 24-hour symptom relief

    PubMed Central

    Schaeffer, Jack; Donnenfeld, Eric

    2016-01-01

    Background: Allergic conjunctivitis (AC) is a common ocular inflammatory manifestation of allergen exposure in sensitized individuals. Signs and symptoms of AC can decrease quality of life, interfere with productivity, and lead to considerable economic burden. Consistent suppression of conjunctival inflammation is necessary for managing AC, but currently available medications require frequent administration and exhibit limited duration of action. Methods: In this review, we summarized AC pathogenesis, diagnosis, and current treatment options as well as their limitations. Findings from the literature were discussed in the context of the unmet need for a once-daily medication with sustained 24-hour effectiveness. Results: Topical pharmacologic treatments are the most common approach for managing extant AC; however, most available medications require multiple daily instillations. Dual-acting antihistamine-mast cell stabilizing agents are currently considered first-line therapeutics for AC because they provide acute relief of signs and symptoms and block persistent inflammation to promote regression of AC. Recent studies of a newly-developed, higher-concentration formulation of a dual-acting antihistamine-mast cell stabilizer have demonstrated that this formulation provides a 24-hour duration of action with once-daily dosing. Conclusions: Dual-acting AC medications exhibit a high degree of overall effectiveness and are well tolerated for chronic use. A newly available once-daily medication that manages signs and symptoms of AC for a full 24 hours may be considered a treatment of choice for patients experiencing seasonal or perennial AC. ClinicalTrials.gov NCT01743027 and NCT01479374 PMID:27466061

  3. Bioenergetical and Cardiac Adaptations of Pilots to a 24-Hour Team Kart Race.

    PubMed

    Durand, Sylvain; Ripamonti, Michael; Rahmani, Abderrahmane; Beaune, Bruno

    2015-11-01

    This study aimed to evaluate energy expenditure (EE) and heart rate (HR) response in kart pilots to successive driving bouts during a 24-hour team race. Eight adult male pilots (22.8 ± 4.1 years) participated to a team 24-hour speedway kart race in Le Mans (France). They alternatively piloted a 390 cm kart. Each relay was 45 minutes long and each pilot performed 4 relays. For each pilot, mean speeds were calculated from lap-to-lap duration recordings using a telemetric infrared timing device. Heart rate values were recorded continuously on 5-second intervals using a portable cardiometric device. Total energy expenditure (EET) and physical activity ratio (PAR) were determined by accelerometry. To pilot a kart during 45 minutes at a mean speed around 62 km·h induces a 300-kcal EET, corresponding to a 5.6-Mets PAR. This effort is responsive for a 73 b·min increase in HR, from 84.1 ± 7.6 to 157.4 ± 11.0 b·min (82% maximal heart rate intensity). However, during this relay period, HR values seemed independent to mean speed performance and bioenergetical values. Thus, in the context of the 24-hour team race, the variability in effort made during each relay and relay succession did not alter bioenergetical adaptation of pilots to kart driving. The high EE and HR values would be better explained by both emotional stress and environmental constraints such as speedway configuration and vibrations. The way how these factors specifically influence bioenergetical demand, and their relative importance, has to be specified to optimize training procedure and recommendations.

  4. Heterogeneity of Prognostic Studies of 24-Hour Blood Pressure Variability: Systematic Review and Meta-Analysis

    PubMed Central

    Taylor, Kathryn S.; Heneghan, Carl J.; Stevens, Richard J.; Adams, Emily C.; Nunan, David; Ward, Alison

    2015-01-01

    In addition to mean blood pressure, blood pressure variability is hypothesized to have important prognostic value in evaluating cardiovascular risk. We aimed to assess the prognostic value of blood pressure variability within 24 hours. Using MEDLINE, EMBASE and Cochrane Library to April 2013, we conducted a systematic review of prospective studies of adults, with at least one year follow-up and any day, night or 24-hour blood pressure variability measure as a predictor of one or more of the following outcomes: all-cause mortality, cardiovascular mortality, all cardiovascular events, stroke and coronary heart disease. We examined how blood pressure variability is defined and how its prognostic use is reported. We analysed relative risks adjusted for covariates including the appropriate mean blood pressure and considered the potential for meta-analysis. Our analysis of methods included 24 studies and analysis of predictions included 16 studies. There were 36 different measures of blood pressure variability and 13 definitions of night- and day-time periods. Median follow-up was 5.5 years (interquartile range 4.2–7.0). Comparing measures of dispersion, coefficient of variation was less well researched than standard deviation. Night dipping based on percentage change was the most researched measure and the only measure for which data could be meaningfully pooled. Night dipping or lower night-time blood pressure was associated with lower risk of cardiovascular events. The interpretation and use in clinical practice of 24-hour blood pressure variability, as an important prognostic indicator of cardiovascular events, is hampered by insufficient evidence and divergent methodologies. We recommend greater standardisation of methods. PMID:25984791

  5. Heterogeneity of prognostic studies of 24-hour blood pressure variability: systematic review and meta-analysis.

    PubMed

    Taylor, Kathryn S; Heneghan, Carl J; Stevens, Richard J; Adams, Emily C; Nunan, David; Ward, Alison

    2015-01-01

    In addition to mean blood pressure, blood pressure variability is hypothesized to have important prognostic value in evaluating cardiovascular risk. We aimed to assess the prognostic value of blood pressure variability within 24 hours. Using MEDLINE, EMBASE and Cochrane Library to April 2013, we conducted a systematic review of prospective studies of adults, with at least one year follow-up and any day, night or 24-hour blood pressure variability measure as a predictor of one or more of the following outcomes: all-cause mortality, cardiovascular mortality, all cardiovascular events, stroke and coronary heart disease. We examined how blood pressure variability is defined and how its prognostic use is reported. We analysed relative risks adjusted for covariates including the appropriate mean blood pressure and considered the potential for meta-analysis. Our analysis of methods included 24 studies and analysis of predictions included 16 studies. There were 36 different measures of blood pressure variability and 13 definitions of night- and day-time periods. Median follow-up was 5.5 years (interquartile range 4.2-7.0). Comparing measures of dispersion, coefficient of variation was less well researched than standard deviation. Night dipping based on percentage change was the most researched measure and the only measure for which data could be meaningfully pooled. Night dipping or lower night-time blood pressure was associated with lower risk of cardiovascular events. The interpretation and use in clinical practice of 24-hour blood pressure variability, as an important prognostic indicator of cardiovascular events, is hampered by insufficient evidence and divergent methodologies. We recommend greater standardisation of methods.

  6. Lack of effect of a 24-hour infusion of iloprost in intermittent claudication.

    PubMed

    Hay, C R; Waller, P C; Carter, C; Cameron, H A; Parnell, L; Ramsay, L E; Preston, F E; Greaves, M

    1987-04-15

    24 hour infusion of iloprost was compared with placebo infusion in 19 patients with stable intermittent claudication using a double blind, balanced crossover design. Despite significant inhibition of platelet aggregation to ADP and collagen (p less than 0.001) and the typical cardiovascular and gastrointestinal side effects, there was no significant effect on treadmill exercise times at any time up to 6 weeks after infusion. The 95% confidence limits indicated that an improvement of more than 25% was unlikely to occur. No significant changes in B thromboglobulin, platelet aggregate ratio, bleeding time, whole blood viscosity and euglobulin clot lysis time were demonstrated.

  7. [The changes in mental working capacity of operators during 24-hour shift work conditions].

    PubMed

    Kal'nysh, V V; Shvets', A V; Ieshchenko, O I

    2011-01-01

    Psychophysiological peculiarities of influence of a 24-hour shift work on the efficiency of operators have been discussed. It was shown that servicemen operators develop significant fatigue as a result of 24 hrs duty services. The informative psychophysiological characteristics which can be reliable indicators of fatigue level are highlighted. Individual psychophysiological indicators of fatigue level, according to different mechanisms of its development, have been proposed. The hypothesis about the existence of several compensatory mechanisms for maintenance of long duty operators' working capacity has been formulated.

  8. Assessing Dietary Intake in Childhood Cancer Survivors: Food Frequency Questionnaire Versus 24-Hour Diet Recalls.

    PubMed

    Zhang, Fang Fang; Roberts, Susan B; Must, Aviva; Wong, William W; Gilhooly, Cheryl H; Kelly, Michael J; Parsons, Susan K; Saltzman, Edward

    2015-10-01

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet recalls (24HRs) against total energy expenditure (TEE) measured using the doubly labeled water method in 16 childhood cancer survivors. Dietary underreporting, assessed by (EI-TEE)/TEE × 100%, was 22% for FFQ and 1% for repeated 24HRs. FFQ significantly underestimates dietary intake and should not be used to assess the absolute intake of foods and nutrients in childhood cancer survivors.

  9. Physician-pharmacist co-management and 24-hour blood pressure control.

    PubMed

    Chen, Ziqian; Ernst, Michael E; Ardery, Gail; Xu, Yinghui; Carter, Barry L

    2013-05-01

    The objectives of this study were to compare indices of 24-hour blood pressure (BP) following a physician-pharmacist collaborative intervention and to describe the associated changes in antihypertensive medications. This was a secondary analysis of a prospective, cluster-randomized clinical trial conducted in 6 family medicine clinics randomized to co-managed (n=3 clinics, 176 patients) or control (n=3 clinics, 198 patients) groups. Mean ambulatory systolic BP (SBP) was significantly lower in the co-managed vs the control group: daytime BP 122.8 mm Hg vs 134.4 mm Hg (P<.001); nighttime SBP 114.8 mm Hg vs 123.7 mm Hg (P<.001); and 24-hour SBP 120.4 mm Hg vs 131.8 mm Hg (P<.001), respectively. Significantly more drug changes were made in the co-managed than in the control group (2.7 vs 1.1 changes per patient, P<.001), and there was greater diuretic use in co-managed patients (79.6% vs 62.6%, P<.001). Ambulatory BPs were significantly lower for the patients who had a diuretic added during the first month compared with those who never had a diuretic added (P<.01). Physician-pharmacist co-management significantly improved ambulatory BP compared with the control group. Antihypertensive drug therapy was intensified much more for patients in the co-managed group.

  10. Deviation of innate circadian period from 24 hours reduces longevity in mice

    PubMed Central

    Libert, Sergiy; Bonkowski, Michael S.; Pointer, Kelli; Pletcher, Scott D.; Guarente, Leonard

    2012-01-01

    Summary The variation of individual lifespans, even in highly inbred cohorts of animals and under strictly controlled environmental conditions, is substantial and not well understood. This variation in part could be due to epigenetic variation, which later affects the animal’s physiology and ultimately longevity. Identification of the physiological properties that impact health and lifespan is crucial for longevity research and the development of anti-aging therapies. Here we measured individual circadian and metabolic characteristics in a cohort of inbred F1 hybrid mice and correlated these parameters to their lifespans. We found that mice with innate circadian periods close to 24 hours (revealed during 30 days of housing in total darkness) enjoyed nearly 20% longer lifespans than their littermates, which had shorter or longer innate circadian periods. These findings show that maintenance of a 24 hour intrinsic circadian period is a positive predictor of longevity. Our data suggest that circadian period may be used to predict individual longevity and that processes that control innate circadian period affect aging. PMID:22702406

  11. Validity of 24-hour dietary recall interviews conducted among volunteers in an adult working community.

    PubMed

    Kahn, H A; Whelton, P K; Appel, L J; Kumanyika, S K; Meneses, J L; Hebert, P R; Woods, M

    1995-11-01

    There is considerable uncertainty regarding the validity of dietary data collected from free-living populations. Nevertheless, few attempts have been made to validate dietary assessment instruments. To address this issue, we compared average daily protein intake estimated from 24-hour dietary recall interviews to protein intake estimated from urinary nitrogen excretion in 24-hour samples. Among 244 community-dwelling adults who volunteered for a hypertension study, men (n = 139) overreported dietary protein intake by 12 to 19%. In contrast, women (n = 105) reported a dietary protein intake almost exactly in agreement with estimates based on urinary nitrogen levels. Thin men reported about one-third more protein intake than was reflected in their urinary nitrogen measurements. Our results suggest that the accuracy of dietary recall estimates may vary across subgroups of the population. Additional information from sufficiently large validation studies would be helpful in determining the role of dietary assessment instruments which are already in wide use in epidemiologic research. Until such information is obtained, doubts will remain regarding the validity of inferences drawn from nutritional epidemiologic studies.

  12. Comparison of 24-hour intragastric pH using four liquid formulations of lansoprazole and omeprazole.

    PubMed

    Sharma, V K

    1999-12-01

    The results of previous studies evaluating the effect of four liquid formulations of proton-pump inhibitors on 24-hour intragastric pH are described. Patients with a gastrostomy who were resident in a Veterans Affairs medical center or its affiliated nursing home were eligible for enrollment in one of four open-label studies in which each patient served as his own control. Patients underwent 24-hour intragastric pH studies before and after receiving seven consecutive days of one of the following liquid formulations of a proton-pump inhibitor administered once daily: omeprazole granules 20 mg in orange juice, lansoprazole granules 30 mg in orange juice, simplified omeprazole suspension 20 mg, and simplified lansoprazole suspension 30 mg. The suspensions were prepared with 10 mL of 8.4% sodium bicarbonate solution. Mean intragastric pH was measured, as was the time pH stayed above 3.0 and 4.0 during the 24-hour period. Six to 14 patients participated in each study. The mean posttreatment pH was 4.9+/-0.8, 4.7+/-0.6, 4.1+/-1.5, and 5.1+/-1.1 for omeprazole granules in orange juice, lansoprazole granules in orange juice, simplified omeprazole suspension, and simplified lansoprazole suspension, respectively. Both drugs in orange juice maintained pH above 4.0 longer than 14 hours and above 3.0 for close to 20 hours, which are the levels deemed optimal for healing erosive esophagitis and duodenal ulcers, respectively. Simplified lansoprazole suspension maintained pH above those thresholds for the optimal times, but simplified omeprazole suspension did not (20 and 15 hr above 3.0, 17 and 12 hr above 4.0 for lansoprazole and omeprazole, respectively). Further development of liquid formulations of proton-pump inhibitors may have important implications for the treatment of acid-related diseases in patients, including children, who are unable to swallow capsules.

  13. Estimating 24-hour urinary sodium excretion from casual urinary sodium concentrations in Western populations: the INTERSALT study.

    PubMed

    Brown, Ian J; Dyer, Alan R; Chan, Queenie; Cogswell, Mary E; Ueshima, Hirotsugu; Stamler, Jeremiah; Elliott, Paul

    2013-06-01

    High intakes of dietary sodium are associated with elevated blood pressure levels and an increased risk of cardiovascular disease. National and international guidelines recommend reduced sodium intake in the general population, which necessitates population-wide surveillance. We assessed the utility of casual (spot) urine specimens in estimating 24-hour urinary sodium excretion as a marker of sodium intake in the International Cooperative Study on Salt, Other Factors, and Blood Pressure. There were 5,693 participants recruited in 1984-1987 at the ages of 20-59 years from 29 North American and European samples. Participants were randomly assigned to test or validation data sets. Equations derived from casual urinary sodium concentration and other variables in the test data were applied to the validation data set. Correlations between observed and estimated 24-hour sodium excretion were 0.50 for individual men and 0.51 for individual women; the values were 0.79 and 0.71, respectively, for population samples. Bias in mean values (observed minus estimated) was small; for men and women, the values were -1.6 mmol per 24 hours and 2.3 mmol per 24 hours, respectively, at the individual level and -1.8 mmol per 24 hours and 2.2 mmol per 24 hours, respectively, at the population level. Proportions of individuals with urinary 24-hour sodium excretion above the recommended levels were slightly overestimated by the models. Casual urine specimens may be a useful, low-burden, low-cost alternative to 24-hour urine collections for estimation of population sodium intakes; ongoing calibration with study-specific 24-hour urinary collections is recommended to increase validity.

  14. Setting Spacecraft Maximum Allowable Concentrations for 1 hour or 24 hour contingency exposures to airborne chemicals

    NASA Technical Reports Server (NTRS)

    Garcia, Hector D.; Limero, Thomas F.; James, John T.

    1992-01-01

    Since the early years of the manned space program, NASA has developed and used exposure limits called Spacecraft Maximum Allowable Concentrations (SMACs) to help protect astronauts from airborne toxicants. Most of these SMACS are based on an exposure duration of 7 days, since this is the duration of a 'typical' mission. A set of 'contingency SMACs' is also being developed for scenarios involving brief (1-hour or 24- hour) exposures to relatively high levels of airborne toxicants from event-related 'contingency' releases of contaminants. The emergency nature of contingency exposures dictates the use of different criteria for setting exposure limits. The NASA JSC Toxicology Group recently began a program to document the rationales used to set new SMACs and plans to review the older, 7-day SMACs. In cooperation with the National Research Council's Committee on Toxicology, a standard procedure has been developed for researching, setting, and documenting SMAC values.

  15. After 24-hour scrub, another tower rollback for the Boeing Delta II rocket carrying Stardust

    NASA Technical Reports Server (NTRS)

    1999-01-01

    As tower rollback begins, the Boeing Delta II rocket carrying the Stardust spacecraft waits on Launch Pad 17-A, Cape Canaveral Air Station, for the second launch attempt at 4:04 p.m. EST. The original launch was scrubbed on Feb. 6 for 24 hours. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  16. Mice increased target biting behaviors 24 hours after co-administration of alcohol and fluoxetine.

    PubMed

    Mamiya, Ping Chao; Matray-Devoti, Judith; Fisher, Hans; Wagner, George C

    2017-02-10

    Increased alcohol consumption has been linked to social isolation. Individuals showed heightened aggression following social isolation. Animals treated with alcohol following social separation showed higher aggression and lower serotonin transmission. Although reduced serotonin transmission in the brain may be related to alcohol induced heightened aggression, it remains unclear whether there are specific brain regions where changes in serotonin transmission are critical for animal aggression following alcohol treatment. In the present study, we isolated mice for 4 - 6 weeks and injected them with alcohol, fluoxetine and alcohol with fluoxetine. We studied their aggression by using two types of behavioral paradigms: isolation-induced attack behavior towards a naïve mouse in a neutral cage, or shock-induced target biting aggression. We observed that alcohol administered at 500 mg/kg significantly increased animal attack behaviors towards naïve mice 30 minutes after injections. This dose of alcohol co-administered with a low dose of fluoxetine (2 mg/kg) further increased the attack behaviors, but with higher doses of fluoxetine decreased the attack behaviors. Alcohol administered at a dose of 1,000 mg/kg significantly decreased the shock-induced target biting rates 24 hours after injections. Interestingly, we observed a significant increase in target biting rates when alcohol was co-administered with fluoxetine at a dose of 16 mg/kg 24 hours after injections. We also observed the same heightened target biting rates when animals were injected with fluoxetine alone. This heightened biting attack engendered by the fluoxetine (alone or in combination with the alcohol) occurred at a time when brain serotonin activity was reduced by these drugs in the frontal lobe and hypothalamus. These observations indicate that heightened biting attack behavior may be associated with reduced serotonergic activity in brain regions regulating aggression.

  17. The effect of Operation 24 Hours on reducing collision in the City of Edmonton.

    PubMed

    Halim, Siana; Jiang, Heming

    2013-09-01

    In the City of Edmonton, in order to reduce the prevalence of collisions, the Operation 24 Hours program (OPS24) was developed by using existing police and transportation services resources. The program uses traditional manned police speed enforcement method, which are supplemented by traffic safety messages displayed on permanent and mobile dynamic messaging signs (DMS). In this paper, collision data analysis was performed by looking at the daily number of collisions from 2008 to 2011 that covers 28 Operation 24 Hours (OPS24) events. The objective of the collision data analysis is to analyze if there is a reduction in collision frequencies after OPS24 was held and examined how long the collision reduction effect last. Weather factors such as temperature, thickness of snow, and wind gust have been considered by many as a great influence on collision occurrences, especially in a city with long and cold winter such as Edmonton. Therefore, collision modeling was performed by considering these external weather factors. To analyze the linear and periodic trend of different collision types (injury, fatal, and property damage only (PDO)) and examine the influence of weather factors on collisions, negative binomial time series model that accounts for seasonality and weather factors was used to model daily collision data. The modeling also considered collision proportion to account for missing traffic volume data; the Gaussian time series model that accounts for seasonality and weather factors was used to model collision proportion. To estimate the collision trend and test for changes in collision levels before/after OPS24, interrupted time series model with segmented regression was used. While for estimating how long the effect of the OPS24 last, change point method was applied.

  18. Estimation of 24-hour urinary sodium excretion using spot urine samples.

    PubMed

    Rhee, Moo-Yong; Kim, Ji-Hyun; Shin, Sung-Joon; Gu, Namyi; Nah, Deuk-Young; Hong, Kyung-Soon; Cho, Eun-Joo; Sung, Ki-Chul

    2014-06-20

    The present study evaluated the reliability of equations using spot urine (SU) samples in the estimation of 24-hour urine sodium excretion (24-HUNa). Equations estimating 24-HUNa from SU samples were derived from first-morning SU of 101 participants (52.4 ± 11.1 years, range 24-70 years). Equations developed by us and other investigators were validated with SU samples from a separate group of participants (n = 224, 51.0 ± 10.9 years, range 24-70 years). Linear, quadratic, and cubic equations were derived from first-morning SU samples because these samples had a sodium/creatinine ratio having the highest correlation coefficient for 24-HUNa/creatinine ratio (r = 0.728, p < 0.001). In the validation group, the estimated 24-HUNa showed significant correlations with measured 24-HUNa values. The estimated 24-HUNa by the linear, quadratic, and cubic equations developed from our study were not significantly different from measured 24-HUNa, while estimated 24-HUNa by previously developed equations were significantly different from measured 24-HUNa values. The limits of agreement between measured and estimated 24-HUNa by six equations exceeded 100 mmol/24-hour in the Bland-Altman analysis. All equations showed a tendency of under- or over-estimation of 24-HUNa, depending on the level of measured 24-HUNa. Estimation of 24-HUNa from single SU by equations as tested in the present study was found to be inadequate for the estimation of an individual's 24-HUNa.

  19. Dietary restraint and disinhibition do not affect accuracy of 24-hour recall in a multiethnic population.

    PubMed

    Ard, Jamy D; Desmond, Renee Ann; Allison, David B; Conway, Joan Marie

    2006-03-01

    Some psychological predictors of eating behaviors have been shown to affect usefulness of methods for dietary assessment. Therefore, this study was conducted to determine the association of dietary restraint and disinhibition with dietary recall accuracy for total energy, fat, carbohydrate, and protein. In a cross-sectional study, data were obtained from 79 male and 71 female non-Hispanic whites and African-American volunteers. Participants selected and consumed all foods for a 1-day period under observation and actual intake was determined. The following day, each participant completed a telephone 24-hour recall using the US Department of Agriculture Multiple-Pass method to obtain recalled intake. The Eating Inventory, which measures dietary restraint and disinhibition, was administered prior to eating any food in the study. Repeated measures analyses of variance were used to determine if dietary restraint or disinhibition were independent predictors of recall accuracy. The mean (+/-standard deviation) age and body mass index of the participants was 43+/-12 years and 29+/-5.5 (calculated as kg/m2), respectively. On average, men overreported intake of energy by 265 kcal and women by 250 kcal; both groups also overreported intake of protein, carbohydrate, and fat. When controlling for body mass index, sex, and race, restraint was a significant independent predictor of energy intake (P=0.004) and negatively correlated with energy intake (r=-0.23, P<0.001). Unlike intake of carbohydrate or protein, fat intake was significantly and negatively associated with dietary restraint (P<0.001; r=-0.3). Dietary restraint did not affect accuracy of recall of intake of energy, fat, carbohydrate, or protein, but was significantly associated with intake of energy and fat. Disinhibition was not related to intake or accuracy. Dietetics professionals should consider dietary restraint a possible reason for a lower than expected estimate of energy intake when using 24-hour recalls.

  20. Reductions in Mean 24-Hour Ambulatory Blood Pressure After 6-Week Treatment With Canagliflozin in Patients With Type 2 Diabetes Mellitus and Hypertension.

    PubMed

    Townsend, Raymond R; Machin, Israel; Ren, Jimmy; Trujillo, Angelina; Kawaguchi, Masato; Vijapurkar, Ujjwala; Damaraju, Chandrasekharrao V; Pfeifer, Michael

    2016-01-01

    This randomized, double-blind, placebo-controlled study evaluated the early effects of canagliflozin on blood pressure (BP) in patients with type 2 diabetes mellitus (T2DM) and hypertension. Patients were randomized to canagliflozin 300 mg, canagliflozin 100 mg, or placebo for 6 weeks and underwent 24-hour ambulatory BP monitoring before randomization, on day 1 of treatment, and after 6 weeks. The primary endpoint was change in mean 24-hour systolic BP (SBP) from baseline to week 6. Overall, 169 patients were included (mean age, 58.6 years; glycated hemoglobin, 8.1%; seated BP 138.5/82.7 mm Hg). At week 6, canagliflozin 300 mg provided greater reductions in mean 24-hour SBP than placebo (least squares mean -6.2 vs -1.2 mm Hg, respectively; P=.006). Numerical reductions in SBP were observed with canagliflozin 100 mg. Canagliflozin was generally well tolerated, with side effects similar to those reported in previous studies. These results suggest that canagliflozin rapidly reduces BP in patients with T2DM and hypertension.

  1. Attempt Quit Smoking 24+ Hours Maps and Data of Model-Based Small Area Estimates - Small Area Estimates

    Cancer.gov

    Attempt Quit Smoking 24+ Hours is defined as a person 18 years of age or older who must have reported smoking at least 100 cigarettes in his/her life, and now does not smoke at all but it has been less than 365 days since completely stopped smoking cigarettes, or now smoke everyday or some days but reported that have made attempt of quitting for more than 24 hours in the past 12 months.

  2. Time-Based Measurement of Personal Mite Allergen Bioaerosol Exposure over 24 Hour Periods

    PubMed Central

    Tovey, Euan R.; Liu-Brennan, Damien; Garden, Frances L.; Oliver, Brian G.; Perzanowski, Matthew S.; Marks, Guy B.

    2016-01-01

    Allergic diseases such as asthma and rhinitis are common in many countries. Globally the most common allergen associated with symptoms is produced by house dust mites. Although the bed has often been cited as the main site of exposure to mite allergens, surprisingly this has not yet been directly established by measurement due to a lack of suitable methods. Here we report on the development of novel methods to determine the pattern of personal exposure to mite allergen bioaerosols over 24-hour periods and applied this in a small field study using 10 normal adults. Air was sampled using a miniature time-based air-sampler of in-house design located close to the breathing zone of the participants, co-located with a miniature time-lapse camera. Airborne particles, drawn into the sampler at 2L/min via a narrow slot, were impacted onto the peripheral surface of a disk mounted on the hour-hand of either a 12 or 24 hour clock motor. The impaction surface was either an electret cloth, or an adhesive film; both novel for these purposes. Following a review of the time-lapse images, disks were post-hoc cut into subsamples corresponding to eight predetermined categories of indoor or outdoor location, extracted and analysed for mite allergen Der p 1 by an amplified ELISA. Allergen was detected in 57.2% of the total of 353 subsamples collected during 20 days of sampling. Exposure patterns varied over time. Higher concentrations of airborne mite allergen were typically measured in samples collected from domestic locations in the day and evening. Indoor domestic Der p 1 exposures accounted for 59.5% of total exposure, whereas total in-bed-asleep exposure, which varied 80 fold between individuals, accounted overall for 9.85% of total exposure, suggesting beds are not often the main site of exposure. This study establishes the feasibility of novel methods for determining the time-geography of personal exposure to many bioaerosols and identifies new areas for future technical

  3. Non-24-Hour Sleep-Wake Disorder Revisited – A Case Study

    PubMed Central

    Garbazza, Corrado; Bromundt, Vivien; Eckert, Anne; Brunner, Daniel P.; Meier, Fides; Hackethal, Sandra; Cajochen, Christian

    2016-01-01

    The human sleep-wake cycle is governed by two major factors: a homeostatic hourglass process (process S), which rises linearly during the day, and a circadian process C, which determines the timing of sleep in a ~24-h rhythm in accordance to the external light–dark (LD) cycle. While both individual processes are fairly well characterized, the exact nature of their interaction remains unclear. The circadian rhythm is generated by the suprachiasmatic nucleus (“master clock”) of the anterior hypothalamus, through cell-autonomous feedback loops of DNA transcription and translation. While the phase length (tau) of the cycle is relatively stable and genetically determined, the phase of the clock is reset by external stimuli (“zeitgebers”), the most important being the LD cycle. Misalignments of the internal rhythm with the LD cycle can lead to various somatic complaints and to the development of circadian rhythm sleep disorders (CRSD). Non-24-hour sleep-wake disorders (N24HSWD) is a CRSD affecting up to 50% of totally blind patients and characterized by the inability to maintain a stable entrainment of the typically long circadian rhythm (tau > 24.5 h) to the LD cycle. The disease is rare in sighted individuals and the pathophysiology less well understood. Here, we present the case of a 40-year-old sighted male, who developed a misalignment of the internal clock with the external LD cycle following the treatment for Hodgkin’s lymphoma (ABVD regimen, four cycles and AVD regimen, four cycles). A thorough clinical assessment, including actigraphy, melatonin profiles and polysomnography led to the diagnosis of non-24-hour sleep-wake disorders (N24HSWD) with a free-running rhythm of tau = 25.27 h. A therapeutic intervention with bright light therapy (30 min, 10,000 lux) in the morning and melatonin administration (0.5–0.75 mg) in the evening failed to entrain the free-running rhythm, although a longer treatment duration and more intense therapy

  4. Low mean impedance in 24-hour tracings and esophagitis in children: a strong connection.

    PubMed

    Salvatore, S; Salvatoni, A; Ummarino, D; Ghanma, A; Van der Pol, R; Rongen, A; Fuoti, M; Meneghin, F; Benninga, M Alexander; Vandenplas, Y

    2016-01-01

    Esophageal multiple intraluminal impedance baseline is an additional impedance parameter that was recently related to esophageal integrity. The aim of this study was to assess the relationship between mean esophageal impedance value and endoscopic findings in a large group of children. Children with symptoms of gastroesophageal reflux submitted to both endoscopy and impedance were included. Esophagitis was graded according to the Los Angeles classification. Mean impedance value was automatically calculated over 24-hour tracings. Data were adjusted for age through z-score transformation using percentiles normalized by the LMS (Lambda for the skew, Mu for the median, and Sigma for the generalized coefficient of variation) method. Nonparametric Mann-Whitney and Kruskal-Wallis tests, multiple, and stepwise regression were used. P-value <0.05 was considered as statistically significant. A total of 298 impedance tracings were analyzed. Endoscopic and histological esophagitis were detected in 30 and 29% patients, respectively. Median baseline z-score was significantly decreased both in proximal (P = 0.02) and distal (P = 0.01) esophagus in patients with endoscopic (but not histological) esophagitis. Patients with more severe esophagitis showed the lowest z-score. Bolus exposure index and the number of reflux episodes were the variables that were significantly associated with the baseline z-score. Impedance z-score is significantly decreased in infants and children with endoscopic esophagitis. Severity of esophagitis, bolus exposure index, and number of reflux episodes are factors influencing mean esophageal impedance.

  5. Deep venous thrombophlebitis: detection with 4-hour versus 24-hour platelet scintigraphy

    SciTech Connect

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Ahmed, F.; Coughlan, J.D.; Jensen, K.C.

    1987-11-01

    Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acute DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal.

  6. Neonatal family care for 24 hours per day: effects on maternal confidence and breast-feeding.

    PubMed

    Wataker, Heidi; Meberg, Alf; Nestaas, Eirik

    2012-01-01

    In family care (FC) program for neonatal intensive care units (NICUs), parents are encouraged to reside together with their infant for 24 hours a day to actively be involved in the care. The aim of this study was to assess the impact of FC on maternal confidence and breast-feeding. Maternal confidence and rate of breast-feeding were assessed in 31 mothers offered FC that included special family rooms in the NICU, and in 30 mothers from a comparable NICU providing traditional care without such facilities. One week prior to hospital discharge, mothers in the FC group felt better informed regarding nursing issues and had more confidence in interpretation of the infants regarding feeding issues and in caregiving without staff attendance (P < .05). They also reported a higher level of empowerment (P < .05). Three months after discharge, the mothers in the FC group had a higher self-reported skill level for interpretation of the infant's signals and knowledge about breast-feeding (P < .05). Despite similar rate of breast-feeding at discharge, more infants in the FC group were breastfed 3 months after discharge (P < .05). An FC program in the NICU promoted better maternal confidence during the hospital stay and 3 months after discharge compared with traditional care.

  7. The Canadian 24-Hour Movement Guidelines for Children and Youth: Implications for practitioners, professionals, and organizations.

    PubMed

    Latimer-Cheung, Amy E; Copeland, Jennifer L; Fowles, Jonathon; Zehr, Lori; Duggan, Mary; Tremblay, Mark S

    2016-06-01

    The new Canadian 24-Hour Movement Guidelines for Children and Youth emphasize the integration of all movement behaviours that occur over a whole day (i.e., light, moderate, and vigorous physical activity, sedentary behaviour, and sleep). These guidelines shift the paradigm away from considering each behaviour in isolation. This concept of the "whole day matters" not only calls for a change in thinking about movement but also for redevelopment of dissemination and implementation practice. Past guideline launch activities largely have aimed to create awareness through passive dissemination strategies (e.g., Website posts, distribution of print resources). For the integrated guidelines to have public health impact, we must move beyond dissemination and raising of awareness to implementation and behaviour change. Shifting this focus requires new, innovative approaches to intervention, including interdisciplinary collaboration, policy change, and refocused service provision. The purpose of this paper is to identify practitioners, professionals, and organizations with potential to disseminate and/or implement the guidelines, discuss possible implementation strategies for each of these groups, and describe the few resources being developed and those needed to support dissemination and implementation efforts. This discussion makes readily apparent the need for a well-funded, comprehensive, long-term dissemination, implementation, and evaluation plan to ensure uptake and activation of the guidelines.

  8. After 24-hour scrub, the Boeing Delta II rocket carrying Stardust waits for launch

    NASA Technical Reports Server (NTRS)

    1999-01-01

    In the late morning light at Launch Pad 17-A, Cape Cananveral Air Station, the fixed utility tower (right) casts a long shadow across the base of the Boeing Delta II rocket (left) waiting to launch the Stardust spacecraft. After a 24-hour scrub, the new targeted launch time is 4:04 p.m. EST. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  9. Obtaining liver tridimensional scaffold through the decellularization of rabbit whole liver in 24 hours

    NASA Astrophysics Data System (ADS)

    Federico, Schliamser; Ayelen, Rinaldi; Romina, Comin; Alba Nelly, Borchert; Adrian, Nari Gustavo; Alicia, Salvatierra Nancy; Mariana Paula, Cid

    2016-04-01

    In the present work, we development a new protocol for liver decellularization in which the hole decellularization was reached over 24 h. Introduction: the availability of transplantable livers is not sufficient to fulfill the current demand for grafts, with the search for therapeutic alternatives having generated different lines of research, one of which is the use of decellularized three-dimensional biological matrices and subsequent cell seeding to obtain a functional organ. Objective: to produce a decellularization protocol from rabbit liver to generate a three-dimensional matrixin which the time period involved didn't pass 24 h. Methods: The decellularization is obtained through the use of water and SDS (0,1-0,3 %), after freezing at -80 degrees, is the best alternative of different physical and/or chemical mechanisms to break down organ cells and leave only the extracellular matriz. After 24 h of retrograde perfusion, a decellularized translucent matrix was generated. To evaluate if the decellularization protocol was successful, with the extracellular matrix being preserved, we carried out histological (light microscopy) and biochemical (DNA quantification) studies. Results: the decellularization process was verified by macroscopic observation of the organ using microscopic observation corroborated the macroscopic results, with the hematoxylin-eosin and Masson staining showing no cells or nuclear material. In addition, the DNA quantification was less than 10% in the decellularized liver compared to control. Finally,the time taken to develop the decellularization protocol was less than 24 hours.

  10. Depressive Symptoms and 24-Hour Ambulatory Blood Pressure in Africans: The SABPA Study

    PubMed Central

    Hamer, Mark; Frasure-Smith, Nancy; Lespérance, François; Harvey, Brian H.; Malan, Nico T.; Malan, Leoné

    2012-01-01

    Disturbances in circadian rhythm might play a central role in the neurobiology of depression. We examined the association between depressive symptoms and 24-hour ambulatory BP in a sample of 405 (197 black and 208 Caucasian) urbanized African teachers aged 25 to 60 yrs (mean 44.6 ± 9.6 yrs). Depressive symptoms were assessed using the self-administered 9-item Patient Health Questionnaire (PHQ-9). After adjusting for age, sex, and ethnicity, participants with severe depressive symptoms (PHQ-9 ≥ 15) had higher odds of hypertension defined from ambulatory BP and/or use of antihypertensive medication (odds ratio = 2.19, 95% CI, 1.00–4.90) in comparison to participants with no symptoms. Compared to Caucasians with no depressive symptoms, those with severe symptoms had blunted nocturnal systolic BP drop of 4.7 mmHg (95% CI, −0.5 to 10.0, P = 0.07). In summary, depressive symptoms were associated with the circadian BP profile in black and Caucasian Africans. PMID:22028954

  11. Comparison of effects of amphotericin B deoxycholate infused over 4 or 24 hours: randomised controlled trial

    PubMed Central

    Eriksson, Urs; Seifert, Burkhard; Schaffner, Andreas

    2001-01-01

    Objective To test the hypothesis that amphotericin B deoxycholate is less toxic when given by continuous infusion than by conventional rapid infusion. Design Randomised, controlled, non-blinded, single centre study. Setting University hospital providing tertiary clinical care. Patients 80 mostly neutropenic patients with refractory fever and suspected or proved invasive fungal infections. Intervention Patients were randomised to receive 0.97 mg/kg amphotericin B by continuous infusion over 24 hours or 0.95 mg/kg by rapid infusion over four hours. Main outcome measures Patients were evaluated for side effects related to infusion, nephrotoxicity, and mortality up to three months after treatment. Analysis was on an intention to treat basis. Results Patients in the continuous infusion group had fewer side effects and significantly reduced nephrotoxicity than those in the rapid infusion group. Overall mortality was higher during treatment and after three months' follow up in the rapid infusion than in the continuous infusion group. Conclusion Continuous infusions of amphotericin B reduce nephrotoxicity and side effects related to infusion without increasing mortality. PMID:11238151

  12. What and how much do we eat? 24-hour dietary recall method.

    PubMed

    Salvador Castell, Gemma; Serra-Majem, Lluis; Ribas-Barba, Lourdes

    2015-02-26

    Diet, along with lifestyle factors, is an important determinant of the health status of an individual and of a community. Dietary assessment at the population level provides us with key information on the frequency and distribution of possible inadequate diets and/or nutritional status. It is also useful as input into the elaboration of food and nutrition policies aiming to improve dietary habits and the health status of a community. This article reviews the characteristics, advantages and limitations of the 24-hour dietary recall method (24hDR), which is one of the most widely used tools in nutrition epidemiology to identify food, energy and nutrient intake in national nutrition surveys, cross-sectional studies, clinical trials and cohort studies as well as in the evaluation of individual dietary intake and Total Diet assessment. To reduce the key factors associated with bias, the importance of previously trained interviewers is highlighted, as well as the role of support materials and the contribution of novel technologies.

  13. After 24-hour scrub, the Boeing Delta II rocket carrying Stardust waits for launch

    NASA Technical Reports Server (NTRS)

    1999-01-01

    After a 24-hour postponement, the Boeing Delta II rocket carrying the Stardust spacecraft waits on Launch Pad 17-A, Cape Canaveral Air Station, for its scheduled launch at 4:04 p.m. EST. Umbilical lines (at top) still attached to the fixed utility tower (at right) feed electricity, air conditioning and coolants for the Stardust spacecraft inside the fairing (enclosing the upper stage) before launch. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  14. After 24-hour scrub, the Boeing Delta II rocket carrying Stardust launches on time

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Flames sear the pristine blue sky behind the Boeing Delta II rocket carrying the Stardust spacecraft after the 4:04:15 p.m. launch from Launch Pad 17-A, Cape Canaveral Air Station. A 24- hour scrub postponed the launch from the originally scheduled date of Feb. 6. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  15. A 24-hour study to investigate persistent chemical exposures associated with clandestine methamphetamine laboratories.

    PubMed

    VanDyke, Mike; Erb, Nicola; Arbuckle, Shawn; Martyny, John

    2009-02-01

    The clandestine manufacture of methamphetamine continues to be a concern across the United States. Although the exposures associated with the actual production process have been evaluated, the persistence of those exposures in a residential setting have not been investigated. This study was designed to document the contamination associated with two red phosphorous methamphetamine "cooks" conducted in a residence and the associated exposures up to 24 hours after the cook. The two cooks were conducted on the first day of the study, and exposures associated with different occupant activity levels were measured the following day. Airborne methamphetamine levels during the cook ranged from 520 microg/m(3) to 760 microg/m(3). On Day 2, airborne levels of methamphetamine ranged from 70 microg/m(3) to 210 microg/m(3) and increased with moderate to high activity levels within the residence. The majority of the methamphetamine measured during both days had a particle size of less than 1 mum, suggesting that the methamphetamine is formed as a condensation aerosol and is readily resuspended from contaminated surfaces. Significant methamphetamine contamination was found in the carpeting and likely was associated with the elevated levels of methamphetamine during activity. Levels of hydrogen chloride and iodine were also detected on Day 2 of the project although at very low levels. The study concluded that exposures may still present a significant inhalation exposure well after the actual cook.

  16. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion: The 2009-2011 Korea National Health and Nutrition Examination Survey.

    PubMed

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-03-01

    Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286-4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the abovementioned variables

  17. No Enhancement of 24-Hour Visuomotor Skill Retention by Post-Practice Caffeine Administration

    PubMed Central

    Hussain, Sara J.; Cole, Kelly J.

    2015-01-01

    Caffeine is widely consumed throughout the world and appears to indirectly facilitate learning and memory through effects on attention and motivation. Animal work indicates that post-training caffeine administration augments inhibitory avoidance memory, spatial memory, and object memory. In humans, post-training caffeine administration enhances the ability to discern between familiar images and new, similar images. However, the effect of post-training caffeine administration on motor memory has not been examined. Therefore, we tested two groups of low caffeine consumers (average weekly consumption ≤500 mg) in a double-blind, placebo-controlled study involving acquisition of a continuous isometric visuomotor tracking skill. On Day 1, subjects completed 5 blocks (150 repetitions) of training on the continuous isometric visuomotor skill and subsequently ingested either 200 mg of caffeine or placebo. On day 2, subjects completed an additional 5 blocks of training. Day 1 mean performance and performance variability were both similar between groups, suggesting that both groups acquired the motor skill similarly. For mean performance on Day 2, patterns of re-learning, mean performance learning magnitudes, mean performance learning rates, and mean performance retention magnitudes were all similar between groups. For performance variability on Day 2, there was a small trend towards increased variability in the caffeine group during re-learning, but performance variability learning magnitudes and performance variability retention magnitudes did not differ between groups. Because motor skill acquisition can also be conceptualized as a reduction in performance variability, these results suggest that there may be a small negative effect of post-practice caffeine administration on memory of a newly-learned visuomotor skill. Overall, we found no evidence to suggest that post-training caffeine administration enhances 24-hour retention of a newly-learned continuous visuomotor

  18. No Enhancement of 24-Hour Visuomotor Skill Retention by Post-Practice Caffeine Administration.

    PubMed

    Hussain, Sara J; Cole, Kelly J

    2015-01-01

    Caffeine is widely consumed throughout the world and appears to indirectly facilitate learning and memory through effects on attention and motivation. Animal work indicates that post-training caffeine administration augments inhibitory avoidance memory, spatial memory, and object memory. In humans, post-training caffeine administration enhances the ability to discern between familiar images and new, similar images. However, the effect of post-training caffeine administration on motor memory has not been examined. Therefore, we tested two groups of low caffeine consumers (average weekly consumption ≤500 mg) in a double-blind, placebo-controlled study involving acquisition of a continuous isometric visuomotor tracking skill. On Day 1, subjects completed 5 blocks (150 repetitions) of training on the continuous isometric visuomotor skill and subsequently ingested either 200 mg of caffeine or placebo. On day 2, subjects completed an additional 5 blocks of training. Day 1 mean performance and performance variability were both similar between groups, suggesting that both groups acquired the motor skill similarly. For mean performance on Day 2, patterns of re-learning, mean performance learning magnitudes, mean performance learning rates, and mean performance retention magnitudes were all similar between groups. For performance variability on Day 2, there was a small trend towards increased variability in the caffeine group during re-learning, but performance variability learning magnitudes and performance variability retention magnitudes did not differ between groups. Because motor skill acquisition can also be conceptualized as a reduction in performance variability, these results suggest that there may be a small negative effect of post-practice caffeine administration on memory of a newly-learned visuomotor skill. Overall, we found no evidence to suggest that post-training caffeine administration enhances 24-hour retention of a newly-learned continuous visuomotor

  19. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted.

  20. Non-24-hour sleep–wake syndrome improved by low-dose valproic acid: a case report

    PubMed Central

    Kurita, Masatake; Moriya, Takahiro; Nishino, Satoshi; Hirata, Eishin; Hirasawa, Noriyasu; Okubo, Yoshiro; Sato, Tadahiro

    2016-01-01

    A woman was diagnosed with non-24-hour sleep–wake syndrome and depressive symptoms. Her depressive symptoms did not respond to standard doses of several antidepressants or mood stabilizers. Furthermore, her sleep–wake cycle remained non-entrained despite treatment with a melatonin-related drug, vitamin B12, and phototherapy. Ultimately, her sleep–wake rhythm was restored to a 24-hour pattern with a low dose of valproic acid, and her depressive symptoms tended to improve as a result of synchronization without antidepressants. Low-dose valproic acid appears to be one of the effective means of entraining circadian rhythms in patients with non-24-hour sleep–wake syndrome, which in turn likely improves associated depressive symptoms. PMID:28008257

  1. To Compare the Microleakage Among Experimental Adhesives Containing Nanoclay Fillers after the Storages of 24 Hours and 6 Months

    PubMed Central

    Mousavinasab, Seyed Mostafa; Atai, Mohammad; Alavi, Bagher

    2011-01-01

    Objectives: To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months. Materials and Methods: Class V cavities were prepared on extracted human molars with the occlusal margins located in enamel and the cervical margins in cementum. Phosphoric acid was applied to the enamel and dentin margins.Subsequently, the cavities were treated using four groups of experimental adhesive systems and restored with a resin composite. Adper Single Bond® was used as control group. After 24- hour and 6- month storages, the samples were subjected to thermocycling shocks and then immersed in silver nitrate as well as developer solution and finally evaluated for leakage. The data were analyzed using SPSS software. Results: Based on Kruskal –Wallis test, significant differences were found between groups regarding microleakage. The Mann- Whitney test showed that Leakage was significantly lower in Adper Single Bond® compared to the other groups in dentinal margins after 24 hours and 6 months and in enamel margins after 6 months. The Wilcoxon Signed Ranks test showed that the enamel leakage in experimental adhesives was significantly lower than dentinal leakage after 24 hours as well as enamel leakage in Adper Single Bond and adhesive with 0.5% PMAA-g-nanoclay was significantly lower than dentinal margins after storage period of 6 months. Conclusion: All the experimental adhesives were effective in reducing enamel leakage after 24 hours, but were not effective in reducing dentinal leakage after 24 hours as well as in enamel and dentinal leakage after a 6-month storage. No improvement was observed in the microleakage in dentin in both short (24 hrs) and long times (6 months). The high microleakage in the adhesives is probably attributed to the high concentration of HEMA in the recipe of the bonding agent. PMID:21566692

  2. Executive Functions are not Affected by 24 Hours of Sleep Deprivation: A Color-Word Stroop Task Study

    PubMed Central

    Dixit, Abhinav; Mittal, Tushar

    2015-01-01

    Background: Sleep is an important factor affecting cognitive performance. Sleep deprivation results in fatigue, lack of concentration, confusion and sleepiness along with anxiety, depression and irritability. Sleep deprivation can have serious consequences in professions like armed forces and medicine where quick decisions and actions need to be taken. Color-Word Stroop task is one of the reliable tests to assess attention and it analyzes the processing of information in two dimensions i.e., reading of words and naming of colour. The evidence regarding the effect of sleep deprivation on Stroop interference is conflicting. The present study evaluated the effect of 24 hours of sleep deprivation on reaction time and interference in Stroop task. Materials and Methods: The present study was done on 30 healthy male medical student volunteers in the age group of 18-25 years after taking their consent and clearance from Institute Ethics Committee. Recordings of Stroop task were at three times: baseline (between 7-9 am), after 12 hours (7-9 pm) and after 24 hours (7-9 am, next day). The subjects were allowed to perform normal daily activities. Results: The study revealed a significant increase in reaction time after 24 hours of sleep deprivation in comparison to baseline and after 12 hours of sleep deprivation. There was no significant change in interference and facilitation after sleep deprivation in comparison to baseline. The number of errors also did not show any significant change after sleep deprivation. Conclusion: The study indicated that there was slowing of responses without change in executive functions after 24 hours of sleep deprivation. It is probable that 24 hours of sleep deprivation does not bring about change in areas of brain affecting executive functions in healthy individuals who have normal sleep cycle. The present study indicated that in professions like armed forces and medicine working 24 hours at a stretch can lead to decrease in motor responses

  3. Interchangeability between 24-hour collection and single spot urines for vanillylmandelic and homovanillic acid levels in the diagnosis of neuroblastoma.

    PubMed

    Cangemi, Giuliana; Barco, Sebastiano; Reggiardo, Giorgio; Viscardi, Elisabetta; Di Cataldo, Andrea; Garaventa, Alberto; Melioli, Giovanni; Conte, Massimo

    2013-12-01

    The determination of the two urinary catecholamine metabolites homovanillic acid (HVA) and vanillylmandelic acid (VMA) is of crucial importance for the diagnosis and follow-up of neuroblastoma (NB). The standard practice for their measurement requires the use of 24-hour collections that are time consuming and difficult to obtain. In this article, we directly demonstrate that 24-hour collections and single spot urines are interchangeable for the determination of HVA and VMA expressed as ratio on creatinine concentration. This study can be useful for a faster management of NB at onset.

  4. 77 FR 65310 - Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... AGENCY 40 CFR Part 81 Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air Quality Standards AGENCY: Environmental Protection Agency (EPA). ACTION: Supplemental... particle (PM 2.5 ) national ambient air quality standards (NAAQS) air quality designations for the...

  5. Accuracy and Usefulness of Select Methods for Assessing Complete Collection of 24-Hour Urine: A Systematic Review.

    PubMed

    John, Katherine A; Cogswell, Mary E; Campbell, Norm R; Nowson, Caryl A; Legetic, Branka; Hennis, Anselm J M; Patel, Sheena M

    2016-05-01

    Twenty-four-hour urine collection is the recommended method for estimating sodium intake. To investigate the strengths and limitations of methods used to assess completion of 24-hour urine collection, the authors systematically reviewed the literature on the accuracy and usefulness of methods vs para-aminobenzoic acid (PABA) recovery (referent). The percentage of incomplete collections, based on PABA, was 6% to 47% (n=8 studies). The sensitivity and specificity for identifying incomplete collection using creatinine criteria (n=4 studies) was 6% to 63% and 57% to 99.7%, respectively. The most sensitive method for removing incomplete collections was a creatinine index <0.7. In pooled analysis (≥2 studies), mean urine creatinine excretion and volume were higher among participants with complete collection (P<.05); whereas, self-reported collection time did not differ by completion status. Compared with participants with incomplete collection, mean 24-hour sodium excretion was 19.6 mmol higher (n=1781 specimens, 5 studies) in patients with complete collection. Sodium excretion may be underestimated by inclusion of incomplete 24-hour urine collections. None of the current approaches reliably assess completion of 24-hour urine collection.

  6. Population Pharmacokinetic Model Characterizing 24-Hour Variation in the Pharmacokinetics of Oral and Intravenous Midazolam in Healthy Volunteers

    PubMed Central

    van Rongen, A; Kervezee, L; Brill, MJE; van Meir, H; den Hartigh, J; Guchelaar, H-J; Meijer, JH; Burggraaf, J; van Oosterhout, F

    2015-01-01

    Daily rhythms in physiology may affect the pharmacokinetics of a drug. The aim of this study was to evaluate 24-hour variation in the pharmacokinetics of the CYP3A substrate midazolam. Oral (2 mg) and intravenous (1 mg) midazolam was administered at six timepoints throughout the 24-hour period in 12 healthy volunteers. Oral bioavailability (population mean value [RSE%] of 0.28 (7.1%)) showed 24-hour variation that was best parameterized as a cosine function with an amplitude of 0.04 (17.3%) and a peak at 12:14 in the afternoon. The absorption rate constant was 1.41 (4.7%) times increased after drug administration at 14:00. Clearance (0.38 L/min (4.8%)) showed a minor 24-hour variation with an amplitude of 0.03 (14.8%) L/min and a peak at 18:50. Simulations show that dosing time minimally affects the concentration time profiles after intravenous administration, while concentrations are higher during the day compared to the night after oral dosing, reflecting considerable variation in intestinal processes. PMID:26380154

  7. Activity-adjusted 24-hour ambulatory blood pressure and cardiac remodeling in children with sleep disordered breathing.

    PubMed

    Amin, Raouf; Somers, Virend K; McConnell, Keith; Willging, Paul; Myer, Charles; Sherman, Marc; McPhail, Gary; Morgenthal, Ashley; Fenchel, Matthew; Bean, Judy; Kimball, Thomas; Daniels, Stephen

    2008-01-01

    Questions remain as to whether pediatric sleep disordered breathing increases the risk for elevated blood pressure and blood pressure-dependent cardiac remodeling. We tested the hypothesis that activity-adjusted morning blood pressure surge, blood pressure load, and diurnal and nocturnal blood pressure are significantly higher in children with sleep disordered breathing than in healthy controls and that these blood pressure parameters relate to left ventricular remodeling. 24-hour ambulatory blood pressure parameters were compared between groups. The associations between blood pressure and left ventricular relative wall thickness and mass were measured. 140 children met the inclusion criteria. In children with apnea hypopnea index <5 per hour, a significant difference from controls was the morning blood surge. Significant increases in blood pressure surge, blood pressure load, and in 24-hour ambulatory blood pressure were evident in those whom the apnea hypopnea index exceeded 5 per hour. Sleep disordered breathing and body mass index had similar effect on blood pressure parameters except for nocturnal diastolic blood pressure, where sleep disordered breathing had a significantly greater effect than body mass index. Diurnal and nocturnal systolic blood pressure, diastolic blood pressure, and mean arterial blood pressure predicted the changes in left ventricular relative wall thickness. Therefore, sleep disordered breathing in children who are otherwise healthy is independently associated with an increase in morning blood pressure surge, blood pressure load, and 24-hour ambulatory blood pressure. The association between left ventricular remodeling and 24-hour blood pressure highlights the role of sleep disordered breathing in increasing cardiovascular morbidity.

  8. Effect of nasal continuous positive airway pressure during sleep on 24-hour blood pressure in obstructive sleep apnea.

    PubMed

    Wilcox, I; Grunstein, R R; Hedner, J A; Doyle, J; Collins, F L; Fletcher, P J; Kelly, D T; Sullivan, C E

    1993-09-01

    Ambulatory blood pressure (BP) was measured noninvasively (Oxford Medilog ABP) at 15-minute intervals for 24 hours before and after 8 weeks of treatment with nasal continuous positive airway pressure (nCPAP) in 19 men with obstructive sleep apnea (OSA). We included both normotensive and hypertensive patients, but hypertensives were studied after withdrawal of antihypertensive drugs. Ambulatory BP before and after treatment was compared using patients as their own controls. Treatment with nCPAP was successfully established in 14 of the 19 patients (74%). Blood pressure fell significantly in patients who were successfully treated: 24-hour mean BP (systolic/diastolic) decreased from 141 +/- 18/89 +/- 11 mm Hg to 134 +/- 19/85 +/- 13 mm Hg (p < 0.05). The reduction in 24-hour mean systolic BP occurred during both day and night, but a significant fall in mean diastolic BP was only observed during the day. The mean blood pressure fell in both normotensive and hypertensive patients. Patients who were inadequately treated with nCPAP had no reduction in mean 24-hour BP. Effective treatment of sleep apnea with nCPAP was associated with a significant fall in both systolic and diastolic BP independent of changes in body weight or alcohol consumption, suggesting that sleep apnea was an independent factor contributing to elevated nighttime and daytime BP in these patients.

  9. Correlations of beta-aminoisobutyric acid in 8 hour and 24 hour urinary samples determined by dual column gas chromatography.

    PubMed

    Sjölin, K E; Nyholm, K K

    1980-05-01

    The correlations of beta-aminoisobutyric acid values in 8 hour and 24 hour urinary samples from 23 healthy persons were determined. beta-AIB in the 8 hour urinary samples was measured by gas chromatography and the 24 hour excretion was calculated from the results of three 8 hour determinations. Simultaneous determinations of urinary creatinine were performed by Jaffe's reaction. Based on the 8 hour values of urinary beta-AIB the results demonstrated a constant excretion of beta-aminoisobutyric acid within the 24 hour periods in both low and high excretors. The precision in distinguishing low and high 24 hour excretors of beta-AIB by using 8 hour values was 91%. If 8 hour values of beta-AIB were related to creatinine the same precision for this calculated ratio was 96.5%. However, for high excretors of beta-AIB, failures were 24.5% by using the 8 hour excretion of beta-AIB as indicator, but only 6.5% by using the ratio.

  10. Urinary saturation and risk factors for calcium oxalate stone disease based on spot and 24-hour urine specimens.

    PubMed

    Ogawa, Yoshihide; Yonou, Hiroyuki; Hokama, Sanehiro; Oda, Masami; Morozumi, Makoto; Sugaya, Kimio

    2003-09-01

    In 222 random spot urine specimens, the calcium concentration and calcium oxalate saturation [DG(CaOx)] were significantly higher among stone formers than among non-stone formers, while the citrate and creatinine-corrected citrate concentrations were lower. In 188 24-hour urine specimens, magnesium excretion was lower among stone formers than non-stone formers, while the creatinine-corrected calcium concentration and DG(CaOx) were higher. Among stone formers, there was no gender difference in the urinary concentrations of calcium, oxalate, citrate, magnesium, and DG(CaOx), but the creatinine-corrected calcium, citrate, and magnesium concentrations were higher in women, as well as 24-hour citrate excretion. The levels of calcium and oxalate have a major influence on DG(CaOx), while citrate and magnesium levels have a minor influence. DG(CaOx) was correlated with calcium and oxalate excretion, as well as with the creatinine-corrected calcium and oxalate concentrations. Approximately 5% of 24-hour urine specimens showed critical supersaturation, 80% showed metastable supersaturation, and 15% were unsaturated. Hypercalciuria or hyperoxaluria was fairly common (30% and 40%) in critically supersaturated urine, while it was less common (22.4% and 8.6%) in metastably supersaturated urine and was not detected in unsaturated urine. Hypocitraturia and/or hypomagnesiuria was more common (63.8-80%) at any saturation. The urinary calcium, oxalate, and citrate concentrations, as well as the creatinine-corrected calcium, oxalate, citrate, and magnesium concentrations and DG(CaOx), showed a significant correlation between 57 paired early morning spot urine and 24-hour urine specimens. The creatinine-corrected calcium and citrate concentrations of the early morning urine specimens were significantly correlated with the levels of calcium and citrate excretion in the paired 24-hour urine specimens. In conclusion, no parameter other than urinary saturation gives more than a vague

  11. Irregular 24-hour Activity Rhythms and the Metabolic Syndrome in Older Adults

    PubMed Central

    Sohail, Shahmir; Yu, Lei; Bennett, David A.; Buchman, Aron S.; Lim, Andrew S.P.

    2015-01-01

    Circadian rhythms – near 24-hour intrinsic biological rhythms – modulate many aspects of human physiology and hence disruption of circadian rhythms may have an important impact on human health. Experimental work supports a potential link between irregular circadian rhythms and several key risk factors for cardiovascular disease including hypertension, obesity, diabetes, and dyslipidemia, collectively termed the metabolic syndrome. While several epidemiological studies have demonstrated an association between shift-work and the components of the metabolic syndrome in working-age adults, there is a relative paucity of data concerning the impact of non-occupational circadian irregularity in older women and men. To address this question, we studied 7 days of actigraphic data from 1137 older woman and men participating in the Rush Memory and Aging Project, a community-based cohort study of the chronic conditions of aging. The regularity of activity rhythms was quantified using the nonparametric interdaily stability metric, and was related to the metabolic syndrome and its components obesity, hypertension, diabetes, and dyslipidemia. More regular activity rhythms were associated with a lower odds of having the metabolic syndrome (OR=0.69, 95%CI=0.60–0.80, p=5.8×10−7), being obese (OR=0.73, 95%CI=0.63–0.85, p=2.5×10−5), diabetic (OR=0.76, 95%CI=0.65–0.90, p=9.3×10−4), hypertensive (OR=0.78, 95%CI=0.66–0.91, p=2.0×10−3), or dyslipidemic (OR=0.82, 95%CI=0.72–0.92, p=1.2×10−3). These associations were independent of differences in objectively measured total daily physical activity or rest, and were not accounted for by prevalent coronary artery disease, stroke, or peripheral artery disease. Moreover, more regular activity rhythms were associated with lower odds of having cardiovascular disease (OR=0.83; 95%CI=0.73–0.95, p=5.7×10−3), an effect that was statistically mediated by the metabolic syndrome. We conclude that irregular activity

  12. Changes in platelet morphology and function during 24 hours of storage.

    PubMed

    Braune, S; Walter, M; Schulze, F; Lendlein, A; Jung, F

    2014-01-01

    aggregates could be visualized microscopically. After four hours, first debris and very small aggregates occurred. After 24 hours, platelet aggregates and also debris progressively increased. In accordance to this, the CASY system revealed an increase of platelet aggregates (up to 90 μm diameter) with increasing storage time. The percentage of CD62P positive platelets and PF4 increased significantly with storage time in resting PRP. When soluble ADP was added to stored PRP samples, the number of activatable platelets decreased significantly over storage time. The present study reveals the importance of a consequent standardization in the preparation of WB and PRP. Platelet morphology and function, particularly platelet reactivity to adherent or soluble agonists in their surrounding milieu, changed rapidly outside the vascular system. This knowledge is of crucial interest, particularly in the field of biomaterial development for cardiovascular applications, and may help to define common standards in the in vitro hemocompatibility testing of biomaterials.

  13. Low adherence to exclusive breastfeeding in Eastern Uganda: A community-based cross-sectional study comparing dietary recall since birth with 24-hour recall

    PubMed Central

    Engebretsen, Ingunn Marie S; Wamani, Henry; Karamagi, Charles; Semiyaga, Nulu; Tumwine, James; Tylleskär, Thorkild

    2007-01-01

    the recall since birth. The 24-hour recall also detected improper infant feeding practices especially in the second half year of life. The dietary recall since birth might be a feasible alternative to monitor infant feeding practices in resource-poor settings. Our study reemphasizes the need for improving infant feeding practices in Eastern Uganda. PMID:17331251

  14. Neighborhood socioeconomic disadvantage is associated with higher ratio of 24-hour urinary sodium to potassium in young Japanese women.

    PubMed

    Murakami, Kentaro; Sasaki, Satoshi; Takahashi, Yoshiko; Uenishi, Kazuhiro

    2009-09-01

    Information on the relationship of neighborhood characteristics to objective indicators of dietary intake is extremely limited. The aim of this observational cross-sectional study was to examine the association between neighborhood socioeconomic status (SES) and 24-hour urinary excretion of sodium and potassium in a population with a high ratio of urinary sodium to potassium. Subjects were 1,032 female Japanese dietetics students aged 18 to 22 years, residing in 293 municipalities in Japan. Neighborhood SES index was defined by seven municipal-level variables, namely unemployment, household overcrowding, poverty, education, income, home ownership, and vulnerable groups, with an increasing index signifying increasing neighborhood socioeconomic disadvantage. Urinary excretion of sodium and potassium was estimated from a single 24-hour urine sample. Neighborhood SES index was not significantly associated with 24-hour urinary excretion of sodium (mean value for each quartile of neighborhood SES: 133.5, 135.2, 126.5, and 141.7 mmol/day, respectively; P for trend 0.10) or potassium (mean value for each quartile: 43.5, 42.2, 38.4, and 42.5 mmol/day, respectively; P for trend 0.44). However, neighborhood SES index was significantly positively associated with the ratio of 24-hour urinary sodium to potassium (mean value for each quartile: 3.14, 3.28, 3.37, and 3.41, respectively; P for trend 0.03). This significant association remained after adjustment for household SES variables (mean value for each quartile: 3.15, 3.35, 3.29, and 3.41, respectively; P for trend 0.04). Neighborhood socioeconomic disadvantage was associated with higher ratio of 24-hour urinary sodium to potassium in young Japanese women.

  15. Microleakage of Two Self-Adhesive Cements in the Enamel and Dentin After 24 Hours and Two Months

    PubMed Central

    Jaberi Ansari, Zahra; Kalantar Motamedi, Mojdeh

    2014-01-01

    Objective: Microleakage is a main cause of restorative treatment failure. In this study, we compared occlusal and cervical microleakage of two self-adhesive cements after 24 hours and two months. Materials and Methods: In this in-vitro experimental study, class II inlay cavities were prepared on 60 sound human third molars. Composite inlays were fabricated with Z100 composite resin. The teeth were randomly assigned to six groups. RelyX-Arc (control), RelyX-Unicem and Maxcem were used for the first three groups and specimens were stored in distilled water at 37°C for 24 hours. The same cements were used for the remaining three groups, but the specimens were stored for 2 months. The teeth were subjected to 500 thermal cycles (5°C and 55°C) and immersed in 0.5% basic fuchsin for 24 hours and then sectioned mesiodistally and dye penetration was evaluated in a class II cavity with occlusal and cervical margins using X20 magnification stereomicroscope. Data were analyzed using Kruskal Wallis and Mann-Whitney U tests. Results: After 24 hours, cements had significant differences only in cervical margin microleakage (P=0.0001) and microleakage of RelyX-Unicem and Maxcem was significantly more than that of RelyX-Arc (both P=0.0001). Cervical microleakage in RelyX-Unicem and Maxcem was greater than occlusal (P=0.0001 and P=0.001, respectively). Microleakage was not significantly different between the occlusal and cervical margins after 2 months. Conclusion: Cervical microleakage was greater than occlusal in RelyX-Unicem and Maxcem after 24h. The greatest microleakage was reported for the cervical margin of RelyX-Unicem after 24 hours. PMID:25584053

  16. Effects of para-aminobenzoic acid (PABA) form and administration mode on PABA recovery in 24-hour urine collections.

    PubMed

    Sharma, Rashmi S; Joy, Raechel C; Boushey, Carol J; Ferruzzi, Mario G; Leonov, Alexei P; McCrory, Megan A

    2014-03-01

    Para-aminobenzoic acid (PABA) has long been used as an objective measure to assess completeness of 24-hour urine collections. However, pharmaceutical-grade PABA for human ingestion is not available in the United States. An alternative, the potassium salt of PABA, aminobenzoate potassium, can be obtained for clinical use, although it has not yet been validated in this role. Both PABA and aminobenzoate potassium can be directly ingested in their tablet or capsule forms or added to food before consumption. Our aim was to investigate the effect of form (PABA vs aminobenzoate potassium) and administration mode (directly ingested as a tablet/capsule vs added to food) on urinary PABA recovery levels. Twenty healthy participants underwent 3 test days separated by two 24-hour wash-out periods. Three test conditions, one on each test day, were investigated in randomized order: PABA tablet, aminobenzoate potassium capsule, and PABA or aminobenzoate potassium in food. Ingestion of each dose was supervised and participants performed the 24-hour urine collections while free-living. The 24-hour urine collections were analyzed for PABA recovery (%R) levels using a colorimetric assay. Recoveries 85% to 110% were deemed complete and those >110% were reanalyzed by high pressure liquid chromatography and mass spectrometry. Only complete collections (>85%R) were included in analyses. The recovery for the PABA tablet, aminobenzoate potassium capsule, and PABA/aminobenzoate potassium in food were similar at 98.8%R±2.0%R, 95.1%R±2.3%R, and 93.2%R±2.1%R, respectively, and did not differ significantly. These results suggest that aminobenzoate potassium may be used as an alternative to PABA for assessing the completeness of 24-hour urine collections and to track compliance with consuming provided diets in community-dwelling studies.

  17. Changes in foot volume, body composition, and hydration status in male and female 24-hour ultra-mountain bikers

    PubMed Central

    2014-01-01

    Background The effects of running and cycling on changes in hydration status and body composition during a 24-hour race have been described previously, but data for 24-hour ultra-mountain bikers are missing. The present study investigated changes in foot volume, body composition, and hydration status in male and female 24-hour ultra-mountain bikers. Methods We compared in 49 (37 men and 12 women) 24-hour ultra-mountain bikers (ultra-MTBers) changes (Δ) in body mass (BM). Fat mass (FM), percent body fat (%BF) and skeletal muscle mass (SM) were estimated using anthropometric methods. Changes in total body water (TBW), extracellular fluid (ECF) and intracellular fluid (ICF) were determined using bioelectrical impedance and changes in foot volume using plethysmography. Haematocrit, plasma [Na+], plasma urea, plasma osmolality, urine urea, urine specific gravity and urine osmolality were measured in a subgroup of 25 ultra-MTBers (16 men and 9 women). Results In male 24-hour ultra-MTBers, BM (P < 0.001), FM (P < 0.001), %BF (P < 0.001) and ECF (P < 0.05) decreased whereas SM and TBW did not change (P > 0.05). A significant correlation was found between post-race BM and post-race FM (r = 0.63, P < 0.001). In female ultra-MTBers, BM (P < 0.05), %BF (P < 0.05) and FM (P < 0.001) decreased, whereas SM, ECF and TBW remained stable (P > 0.05). Absolute ranking in the race was related to Δ%BM (P < 0.001) and Δ%FM in men (P < 0.001) and to Δ%BM (P < 0.05) in women. In male ultra-MTBers, increased post-race plasma urea (P < 0.001) was negatively related to absolute ranking in the race, Δ%BM, post-race FM and Δ%ECF (P < 0.05). Foot volume remained stable in both sexes (P > 0.05). Conclusions Male and female 24-hour ultra-MTBers experienced a significant loss in BM and FM, whereas SM remained stable. Body weight changes and increases in plasma urea do not reflect a change in body hydration status. No oedema

  18. Perfusion-CT - Can We Predict Acute Pancreatitis Outcome within the First 24 Hours from the Onset of Symptoms?

    PubMed Central

    Pieńkowska, Joanna; Gwoździewicz, Katarzyna; Skrobisz-Balandowska, Katarzyna; Marek, Iwona; Kostro, Justyna; Szurowska, Edyta; Studniarek, Michał

    2016-01-01

    Purpose Severe acute pancreatitis (AP) is still a significant clinical problem which is associated with a highly mortality. The aim of this study was the evaluation of prognostic value of CT regional perfusion measurement performed on the first day of onset of symptoms of AP, in assessing the risk of developing severe form of acute pancreatitis. Material and Methods 79 patients with clinical symptoms and biochemical criteria indicative of acute pancreatitis (acute upper abdominal pain, elevated levels of serum amylase and lipase) underwent perfusion CT within 24 hours after onset of symptoms. The follow-up examinations were performed after 4–6 days to detect progression of the disease. Perfusion parameters were compared in 41 people who developed severe form of AP (pancreatic and/or peripancreatic tissue necrosis) with parameters in 38 consecutive patients in whom course of AP was mild. Blood flow, blood volume, mean transit time and permeability surface area product were calculated in the three anatomic pancreatic subdivisions (head, body and tail). At the same time the patient's clinical status was assessed by APACHE II score and laboratory parameters such as CRP, serum lipase and amylase, AST, ALT, GGT, ALP and bilirubin were compared. Results Statistical differences in the perfusion parameters between the group of patients with mild and severe AP were shown. Blood flow, blood volume and mean transit time were significantly lower and permeability surface area product was significantly higher in patients who develop severe acute pancreatitis and presence of pancreatic and/or peripancreatic necrosis due to pancreatic ischemia. There were no statistically significant differences between the two groups in terms of evaluated on admission severity of pancreatitis assessed using APACHE II score and laboratory tests. Conclusions CT perfusion is a very useful indicator for prediction and selection patients in early stages of acute pancreatitis who are at risk of

  19. Study on Operation Optimization of Pumping Station's 24 Hours Operation under Influences of Tides and Peak-Valley Electricity Prices

    NASA Astrophysics Data System (ADS)

    Yi, Gong; Jilin, Cheng; Lihua, Zhang; Rentian, Zhang

    2010-06-01

    According to different processes of tides and peak-valley electricity prices, this paper determines the optimal start up time in pumping station's 24 hours operation between the rating state and adjusting blade angle state respectively based on the optimization objective function and optimization model for single-unit pump's 24 hours operation taking JiangDu No.4 Pumping Station for example. In the meantime, this paper proposes the following regularities between optimal start up time of pumping station and the process of tides and peak-valley electricity prices each day within a month: (1) In the rating and adjusting blade angle state, the optimal start up time in pumping station's 24 hours operation which depends on the tide generation at the same day varies with the process of tides. There are mainly two kinds of optimal start up time which include the time at tide generation and 12 hours after it. (2) In the rating state, the optimal start up time on each day in a month exhibits a rule of symmetry from 29 to 28 of next month in the lunar calendar. The time of tide generation usually exists in the period of peak electricity price or the valley one. The higher electricity price corresponds to the higher minimum cost of water pumping at unit, which means that the minimum cost of water pumping at unit depends on the peak-valley electricity price at the time of tide generation on the same day. (3) In the adjusting blade angle state, the minimum cost of water pumping at unit in pumping station's 24 hour operation depends on the process of peak-valley electricity prices. And in the adjusting blade angle state, 4.85%˜5.37% of the minimum cost of water pumping at unit will be saved than that of in the rating state.

  20. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

    PubMed Central

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. Results A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Conclusions Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. PMID:27286119

  1. Antimicrobial Prophylaxis in Instrumented Spinal Fusion Surgery: A Comparative Analysis of 24-Hour and 72-Hour Dosages

    PubMed Central

    Abraham, Vineet Thomas; Ravichandran, Mirunalini; Achimuthu, Rajamani

    2016-01-01

    Study Design Prospective study. Purpose To compare the efficacy of 24-hour and 72-hour antibiotic prophylaxis in preventing surgical site infections (SSIs). Overview of Literature Antimicrobial prophylaxis in surgical practice has become a universally accepted protocol for minimizing postoperative complications related to infections. Although prophylaxis is an accepted practice, a debate exists with regard to the antibiotic type and its administration duration for various surgical procedures. Methods Our institute is a tertiary care hospital with more than 100 spinal surgeries per year for various spine disorders in the department of orthopedics. We conducted this prospective study in our department from June 2012 to January 2015. A total of 326 patients were enrolled in this study, with 156 patients in the 72-hour antibiotic prophylaxis group (group A) and 170 patients in the 24-hour group (group B). Cefazolin was the antibiotic used in both groups. Two surgeons were involved in conducting all the spinal procedures. Our study compared SSIs among patients undergoing instrumented spinal fusion. Results The overall rate of SSIs was 1.8% with no statistical difference between the two groups. Conclusions The 24-hour antimicrobial prophylaxis is as effective as the 72-hour dosage in instrumented spinal fusion surgery. PMID:27994776

  2. Vanilmandelic acid and homovanillic acid levels in patients with neural crest tumor: 24-hour urine collection versus random sample.

    PubMed

    Gregianin, L J; McGill, A C; Pinheiro, C M; Brunetto, A L

    1997-01-01

    Neuroblastoma is the most common solid tumor in childhood and is the most frequent neural crest tumor (NCT). More than 90% of the patients excrete high levels of vanilmandelic acid (VMA) and homovanillic acid (HVA) in the urine. Original biochemical methods for measuring these two metabolites of catecholamines employed a collection of urine for 24 hours to avoid errors related to circadian cycle variations. More recently, attempts have been made to replace the 24-hour collections by random samples (RSs). This has practical advantages particularly for young children. The objective of this study is to assess whether urinary VMA related to urinary creatinine levels can be determined reliably by the method of Pisano et al. from RSs in patients with NCT. The determination of the consumption of VMA in urine stored for prolonged periods of time was also studied. We found a good correlation between the values of metabolites of catecholamines in RSs compared with 24-hour urine collections. There was consumption of VMA in urine samples after storage. We conclude that determination of VMA in RSs of urine by Pisano's method may identify NCT production of catecholamines and that the consumption of these catecholamines is an important factor to consider in the interpretation of values obtained with stored urine specimens.

  3. Assessment of 24-hours Aldosterone Administration on Protein Abundances in Fluorescence-Sorted Mouse Distal Renal Tubules by Mass Spectrometry

    PubMed Central

    Jensen, Thomas B; Pisitkun, Trairak; Hoffert, Jason D; Jensen, Uffe B; Fenton, Robert A; Praetorius, Helle A; Knepper, Mark A; Praetorius, Jeppe

    2013-01-01

    Background/Aims Aldosterone exerts multiple long-term effects in the distal renal tubules. The aim of this study was to establish a method for identifying proteins in these tubules that change in abundance by only 24-hours aldosterone administration. Methods Mice endogenously expressing green fluorescent protein (eGFP) in the connecting tubule and cortical collecting ducts were treated with a subcutaneous injection of 2.0 mg/kg aldosterone or vehicle (n=5), and sacrificed 24 hours later. Suspensions of single cells were obtained enzymatically, and eGFP positive cells were isolated by fluorescence activated cell sorting (FACS). Samples of 100 μg proteins were digested with trypsin and labeled with 8-plex iTRAQ reagents and processed for liquid chromatography tandem mass spectrometry (LC-MS/MS). Results FACS yielded 1.4 million cells per mouse. The LC-MS/MS spectra were matched to peptides by the SEQUEST search algorithm, which identified 3002 peptides corresponding to 506 unique proteins of which 20 significantly changed abundance 24-hours after aldosterone injection. Conclusion We find the method suitable and useful for studying hormonal effects on protein abundance in distal tubular segments. PMID:23428628

  4. Experience with noninvasive ambulatory 24-hour blood pressure recording in a community hospital.

    PubMed

    van de Weijgert, E J; Braun, J J

    1992-04-01

    In 40 subjects (23 treated with antihypertensive medication), 24-h ambulatory blood pressure was measured with an oscillometric blood pressure monitor (Spacelabs model 90202). We studied applicability in the out-patient department with regard to patient tolerance, correlation with mercury manometer measurements, 24-h blood pressure variability and the use in detecting "white-coat" hypertension. The measurements were tolerated quite well except for complaints of sleep disturbance and local irritation from the cuff. The average percentage of missed measuring points was 9.2%. Correlation between blood pressure with the mercury manometer and the Spacelabs monitor (averages of three consecutive readings) was: systolic 0.87 and diastolic 0.73 (P less than 0.001). No evidence for systematic error between the two methods was found. Diurnal blood pressure variation was significant with an average night-time drop of 12 +/- 15 mmHg systolic and 12 +/- 11 mmHg diastolic. "Office" blood pressure measured with the Spacelabs monitor was in the hypertensive range for 28 patients (systolic greater than or equal to 160 and/or diastolic greater than or equal to 95 mmHg). Only 15 of these subjects still met the hypertension criteria on the basis of mean daytime ambulatory blood pressure values. When ambulatory blood pressures during arbitrary 3-h periods of the daytime were studied, the number of patients with established hypertension did not change. The patients with this "office" or "white-coat" hypertensive response could not be distinguished on the basis of variability in daytime blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Association of target organ damage with 24-hour systolic and diastolic blood pressure levels and hypertension subtypes in untreated Chinese.

    PubMed

    Wei, Fang-Fei; Li, Yan; Zhang, Lu; Xu, Ting-Yan; Ding, Feng-Hua; Staessen, Jan A; Wang, Ji-Guang

    2014-02-01

    The association of target organ damage with 24-hour systolic and diastolic blood pressure levels and ambulatory hypertension subtypes has not yet been examined in untreated Chinese patients. We measured left ventricular mass index by echocardiography (n=619), the urinary albumin:creatinine ratio (n=1047), and aortic pulse wave velocity by tonometry (n=1013) in 1047 untreated subjects (mean age, 50.6 years; 48.9% women). Normotension was a 24-hour systolic/diastolic blood pressure <130/<80 mm Hg. Hypertension subtypes were isolated diastolic hypertension and mixed systolic plus diastolic hypertension. We assessed associations of interest by multivariable-adjusted linear models. Using normotension as reference, mixed hypertension was associated with higher (P≤0.003) left ventricular mass index (+4.31 g/m(2)), urinary albumin:creatinine ratio (+1.63 mg/mmol), and pulse wave velocity (+0.76 m/s); and isolated diastolic hypertension was associated with similar left ventricular mass index and pulse wave velocity (P≥0.39), but higher urinary albumin:creatinine ratio (+1.24 mg/mmol; P=0.002). In younger participants (<55 years), the mutually independent effect sizes associated with 1 SD increases in 24-hour systolic/diastolic blood pressure were +3.31/-0.36 g/m(2) (P=0.009/0.79) for left ventricular mass index, +1.15/+1.14 mg/mmol (P=0.02/0.04) for the urinary albumin:creatinine ratio, and +0.54/-0.05 m/s (P<0.001/0.54) for pulse wave velocity. In older participants, these estimates were +3.58/+0.30 g/m(2) (P=0.045/0.88), +1.23/+1.05 mg/mmol (P=0.002/0.54), and +0.76/-0.49 m/s (P<0.001/<0.001), respectively. In conclusion, 24-hour systolic blood pressure and mixed hypertension are major determinants of target organ damage irrespective of age and target organ, whereas 24-hour diastolic blood pressure and isolated diastolic hypertension only relate to the urinary albumin:creatinine ratio below middle age.

  6. 24-hour control of body temperature in rats. I. Integration of behavioral and autonomic effectors.

    PubMed

    Gordon, C J

    1994-07-01

    Some studies suggest that the nocturnal elevation in core temperature (Tc) of the rat is mediated by an elevation in the set point. The role of set point can be assessed if behavioral effectors are measured simultaneously with other thermoregulatory effectors and Tc over a 24-h period. Selected ambient temperature (STa) and motor activity (MA) were measured in rats housed in a temperature gradient system with a 12:12-h photoperiod (lights on 0600 h). Tc and heart rate (HR) were monitored by telemetry. During the light phase, STa, Tc, HR, and MA were relatively stable with values 29.0 degrees C, 37.1 degrees C, 310 beats/min, and 1-2 m/h, respectively. During the light-to-dark transition there were abrupt elevations in Tc, HR, and MA but no change in STa. STa decreased during the dark phase and reached a nadir of 23 degrees C at 0500 h. All variables recovered to basal levels within 3-4 h after the onset of the light phase. Overall, autonomic effectors control the elevation in Tc during the onset of the dark phase while behavioral effectors have little if any role. Behavioral thermoregulation is important in two ways: 1) the selection of cooler Ta values at night to prevent an excess elevation in Tc and 2) a preference for cooler Ta values before the light phase to facilitate the recovery of Tc.

  7. Caffeine does not entrain the circadian clock but improves daytime alertness in blind patients with non-24-hour rhythms

    PubMed Central

    St. Hilaire, Melissa A.; Lockley, Steven W.

    2015-01-01

    Objective/Background Totally blind individuals are highly likely to suffer from Non-24-Hour Sleep-Wake Disorder due to a failure of light to reset the circadian pacemaker in the suprachiasmatic nuclei. In this outpatient case series, we investigated whether daily caffeine administration could entrain the circadian pacemaker in non-entrained blind patients to alleviate symptoms of non-24-hour sleep–wake disorder. Patients/Methods Three totally blind males (63.0 ± 7.5 years old) were studied at home over ~4 months. Urinary 6-sulphatoxymelatonin (aMT6s) rhythms were measured for 48 h every 1–2 weeks. Participants completed daily sleep–wake logs, and rated their alertness and mood using nine-point scales every ~2–4 h while awake on urine sampling days. Caffeine capsules (150 mg per os) were self-administered daily at 10 a.m. for approximately one circadian beat cycle based on each participant's endogenous circadian period τ and compared to placebo (n = 2) or no treatment (n = 1) in a single-masked manner. Results Non-24-h aMT6s rhythms were confirmed in all three participants (τ range = 24.32–24.57 h). Daily administration of 150 mg caffeine did not entrain the circadian clock. Caffeine treatment significantly improved daytime alertness at adverse circadian phases (p < 0.0001) but did not decrease the occurrence of daytime naps compared with placebo. Conclusions Although caffeine was able to improve daytime alertness acutely and may therefore provide temporary symptomatic relief, the inability of caffeine to correct the underlying circadian disorder means that an entraining agent is required to treat Non-24-Hour Sleep–Wake Disorder in the blind appropriately. PMID:25891543

  8. Effects of Fibrinogen Concentrate on Thrombin Generation, Thromboelastometry Parameters, and Laboratory Coagulation Testing in a 24-Hour Porcine Trauma Model

    PubMed Central

    Zentai, Christian; Solomon, Cristina; van der Meijden, Paola E. J.; Spronk, Henri M. H.; Schnabel, Jonas; Rossaint, Rolf

    2015-01-01

    Introduction: In a 24-hour porcine model of liver injury, we showed that fibrinogen supplementation does not downregulate endogenous fibrinogen synthesis. Here we report data from the same study showing the impact of fibrinogen on coagulation variables. Materials and Methods: Coagulopathy was induced in 20 German land race pigs by hemodilution and blunt liver injury. Animals randomly received fibrinogen concentrate (100 mg/kg) or saline. Coagulation parameters were assessed and thromboelastometry (ROTEM) was performed. Results: Fibrinogen concentrate significantly reduced the prolongations of EXTEM clotting time, EXTEM clot formation time, and prothrombin time induced by hemodilution and liver injury. A decrease in clot strength was also ameliorated. Endogenous thrombin potential was significantly higher in the fibrinogen group than in the control group, 20 minutes (353 ± 24 vs 289 ± 22 nmol/L·min; P < .05) and 100 minutes (315 ± 40 vs 263 ± 38 nmol/L·min; P < .05) after the start of infusion. However, no significant between-group differences were seen in other thrombin generation parameters or in d-dimer or thrombin–antithrombin levels. Fibrinogen–platelet binding was reduced following liver injury, with no significant differences between groups. No significant between-group differences were observed in any parameter at ∼12 and ∼24 hours. Conclusion: This study suggests that, in trauma, fibrinogen supplementation may shorten some measurements of the speed of coagulation initiation and produce a short-lived increase in endogenous thrombin potential, potentially through increased clotting substrate availability. Approximately 12 and 24 hours after starting fibrinogen concentrate/saline infusion, all parameters measured in this study were comparable in the 2 study groups. PMID:25948634

  9. Reliability and predictive validity of energy intake measures from the 24-hour dietary recalls of homebound older adults.

    PubMed

    Sun, Yanhui; Roth, David L; Ritchie, Christine S; Burgio, Kathryn L; Locher, Julie L

    2010-05-01

    Twenty-four-hour dietary recalls are used frequently to study homebound older adults' eating behaviors. However, the reliability and predictive validity of this method have not been established in this population. The purpose of this study was to examine whether homebound older adults provide reliable and valid measures of total energy intake in 24-hour dietary recalls. Two hundred thirty homebound older adults were interviewed in their homes using a questionnaire to assess eating behaviors and factors that could affect those behaviors. Participants completed three 24-hour dietary recalls at baseline and again at 6-month follow-up. Two subsamples were identified for analyses. For participants who were not hospitalized during the 6-month interval and had their weight measured at both assessments (n=52), sufficient test-retest reliability of energy intake was observed (r=0.59), but energy intake deficiencies relative to estimated energy requirements did not predict actual weight loss (r=0.08). When this sample was supplemented with 91 participants who experienced any adverse event (weight loss of 2.5% or more, hospitalization, institutionalization, or mortality) in the 6-month period (n=143), adverse events were more likely to occur for those with insufficient energy intake (odds ratio 3.49, P=0.009), and in white participants compared to African-American participants (odds ratio 3.13, P=0.016). Adequate test-retest reliability of the 24-hour dietary recall was demonstrated, but additional research with larger samples and longer follow-up intervals is needed to better evaluate the predictive validity of energy intake measures for this population.

  10. Extent and Determinants of Thermogenic Responses to 24 Hours of Fasting, Energy Balance, and Five Different Overfeeding Diets in Humans

    PubMed Central

    Pannacciulli, Nicola; Bonfiglio, Susan; Pacak, Karel; Krakoff, Jonathan

    2013-01-01

    Context: Individual variation in the ability to convert excess calories to heat and the effects of dietary macronutrient composition are unclear. Objective: Stability and determinants of the energy expenditure (EE) response to overconsumption were assessed. Design, Setting, and Participants: Twenty subjects (75% male) with normal glucose regulation were evaluated during 24 hours each of energy balance, fasting, and 5 different diets with 200% energy requirements in a clinical research unit. Interventions: Five 1-day overfeeding diets were given in random order: high carbohydrate (75%) and low protein (3%); high carbohydrate and normal protein (20%); high fat (46%) and low protein; high fat (60%) and normal protein; and balanced (50% carbohydrates, 20% protein). Main Outcome Measures: The 24-hour EE, sleeping EE, and thermic effect of food (TEF) during each diet were measured with a metabolic chamber. Appetitive hormones were measured before and after the diets. Results: The EE response to overfeeding exhibited good intraindividual reproducibility. Similar increases above eucaloric feeding in 24-hour EE (mean 10.7 ± 5.7%, P < .001; range 2.9–18.8%) and sleeping EE (14.4 ± 11.3%, P < .001; range 1.0–45.1%) occurred when overfeeding diets containing 20% protein, despite differences in fat and carbohydrate content, but the EE response during overfeeding diets containing 3% protein was attenuated. The percent body fat negatively correlated with TEF during normal protein overfeeding (r = −0.53, P < .01). Fasting peptide YY negatively correlated with TEF (r = −0.56, P < .01) and the increase in sleeping EE (r = −0.54, P < .01) during overfeeding. Conclusions: There is an intrinsic EE response to overfeeding that negatively associates with adiposity, although it represents a small percentage of consumed calories. PMID:23666976

  11. Resistance training decreases 24-hour blood pressure in women with metabolic syndrome

    PubMed Central

    2013-01-01

    Background The purpose of this study was to verify the effects of eight weeks of resistance training (RT) on 24 hour blood pressure (BP) in patients with and without metabolic syndrome (MetS). Methods Seventeen women volunteered to participate in this study, 9 with MetS (37.0 ± 8.7 yrs; body mass 77.3 ± 9.7 kg; body mass index 30.3 ± 4.2 kg · m-2) and 8 without MetS (35.1 ± 7.2 yrs; body mass 61.3 ± 8.1 kg; body mass index 24.2 ± 2.5 kg · m-2). Individuals were subjected to eight weeks (3 times/week) of whole body RT comprised of one exercise for each main muscle group with three sets of 8–12 repetitions of each subject’s maximal load . A rest interval of one minute was allowed between sets and exercises. Twenty-four hour BP was measured by ambulatory blood pressure monitoring. Results Mean and diastolic night-time BP decreased (−3.9 mmHg, p = 0.04; -5.5 mmHg, p = 0.03, respectively) after eight weeks of training in MetS patients. This decrease was observed at 11:00 pm, 02:00 am (only diastolic), 07:00 am, and 6:00 pm. There was no training effect on BP in women without MetS. Conclusions Considering the elevation of BP as a contributor to the pathogenesis of MetS, and also to the increase of cardiovascular risk, this study supports RT as a non-pharmacological therapy in the management of BP control for MetS. PMID:23711286

  12. Electronic Dietary Intake Assessment (e-DIA): Comparison of a Mobile Phone Digital Entry App for Dietary Data Collection With 24-Hour Dietary Recalls

    PubMed Central

    O'Connor, Sarah; Giannelli, Valentina; Yap, Megan LH; Tang, Lie Ming; Roy, Rajshri; Louie, Jimmy Chun Yu; Hebden, Lana; Kay, Judy; Allman-Farinelli, Margaret

    2015-01-01

    Background The electronic Dietary Intake Assessment (e-DIA), a digital entry food record mobile phone app, was developed to measure energy and nutrient intake prospectively. This can be used in monitoring population intakes or intervention studies in young adults. Objective The objective was to assess the relative validity of e-DIA as a dietary assessment tool for energy and nutrient intakes using the 24-hour dietary recall as a reference method. Methods University students aged 19 to 24 years recorded their food and drink intake on the e-DIA for five days consecutively and completed 24-hour dietary recalls on three random days during this 5-day study period. Mean differences in energy, macro-, and micronutrient intakes were evaluated between the methods using paired t tests or Wilcoxon signed-rank tests, and correlation coefficients were calculated on unadjusted, energy-adjusted, and deattenuated values. Bland-Altman plots and cross-classification into quartiles were used to assess agreement between the two methods. Results Eighty participants completed the study (38% male). No significant differences were found between the two methods for mean intakes of energy or nutrients. Deattenuated correlation coefficients ranged from 0.55 to 0.79 (mean 0.68). Bland-Altman plots showed wide limits of agreement between the methods but without obvious bias. Cross-classification into same or adjacent quartiles ranged from 75% to 93% (mean 85%). Conclusions The e-DIA shows potential as a dietary intake assessment tool at a group level with good ranking agreement for energy and all nutrients. PMID:26508282

  13. The Automated Self-Administered 24-Hour Dietary Recall for Children, 2012 version, for youth aged 9 to 11 Years: A validation study

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our objective was to validate the 2012 version of the Automated Self-Administered 24-Hour Dietary Recall for Children (ASA24-Kids-2012), a self-administered web-based 24-hour dietary recall (24hDR) instrument, among children aged 9 to 11 years, in two sites using a quasiexperimental design. In one s...

  14. Determination of and correlation between urine protein excretion and urine protein-to-creatinine ratio values during a 24-hour period in healthy horses and ponies.

    PubMed

    Uberti, Benjamin; Eberle, D Bernard; Pressler, Barrak M; Moore, George E; Sojka, Janice E

    2009-12-01

    OBJECTIVE-To determine whether urine protein-to-creatinine (UP:C) ratio assessment provides an estimate of urine protein excretion (UPE) over a 24-hour period in horses and ponies, establish a preliminary UP:C ratio reference range, and determine UP:C ratio variation over time in healthy equids. ANIMALS-11 female horses and 6 female ponies. PROCEDURES-Urine was collected from all equids at 4-hour intervals for 24 hours. Total 24-hour UPE (mg of protein/kg of body weight) and UP:C ratio were determined; these variables were also assessed in aliquots of urine collected at 4-hour intervals. On 2 additional days, urine samples were also obtained from 6 horses (1 sample/horse/d) to determine day-to-day variation in UP:C ratio. Correlation between 4-hour or 24-hour UPE and UP:C ratio values was assessed. Reference ranges for 24-hour UPE, 24-hour UP:C ratio, and 4-hour UP:C ratios were calculated as central 95th percentiles of observed values. RESULTS-Mean 24-hour UPE (4.28 +/- 2.99 mg/kg) and 24-hour UP:C ratio (0.0 to 0.37) had excellent correlation (R = 0.826; P < 0.001) in both horses and ponies; analysis of 4-hour data also revealed good correlation (R = 0.782; P < 0.001) with these variables. Calculated UPE and UP:C ratio reference ranges were similar to established ranges in other species. Day-to-day variability in UP:C ratio was minimal, and all results were within the reference range calculated by use of the 24-hour urine samples. CONCLUSIONS AND CLINICAL RELEVANCE-Assessment of the UP:C ratio appears to be a reliable method for estimating 24-hour UPE in horses and ponies.

  15. Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

    NASA Technical Reports Server (NTRS)

    Engelke, K. A.; Shea, J. D.; Doerr, D. F.; Convertino, V. A.

    1992-01-01

    To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

  16. Urine 24-hour volume

    MedlinePlus

    ... in a day, such as: Creatinine Sodium Potassium Nitrogen Protein This test may also be done if ... disease Potassium urine test Sodium urine test Urea nitrogen urine test Urination - excessive amount Urine output - decreased ...

  17. 24-hour urine protein

    MedlinePlus

    ... your doctor may be able to order a test that is done on just one urine sample (protein-to-creatinine ratio). Normal Results The normal value is less than 100 milligrams per day or less than 10 milligrams per deciliter ... of these tests. Normal value ranges may vary slightly among different ...

  18. Ultra-Rapid dUT1 Measurements on Japan-Fennoscandian Baselines - Application to 24-hour Sessions

    NASA Technical Reports Server (NTRS)

    Matsuzaka, Shigeru; Kurihara, Shinobu; Sekido, Mamoru; Hobiger, Thomas; Haas, Rudiger; Ritakari, Jouko; Wagner, Jan

    2010-01-01

    GSI, NICT, OSO, and MRO have been engaged in Ultra-rapid dUT1 experiments since 2007 aiming at the technological possibility of real-time dUT1 results using the e-VLBI technique. We have already successfully determined dUT1 in less than four minutes after the end of an experimental Intensive session in 2008, and at present we routinely get the results within 30 minutes for regular Intensives. In 2009 we applied the technique to 24-hour sessions and continuously obtained dUT1 values by processing and analyzing Tsukuba Onsala data in near real-time. It showed a detailed behavior of UT1 variations, which could be very valuable for scientific study as well as for precise prediction of UT1-UTC.

  19. 24-hour energy expenditure and substrate oxidation rates are unaffected by body fat distribution in obese women.

    PubMed

    Buemann, B; Astrup, A; Quaade, F; Madsen, J

    1994-01-01

    Twenty-four-hour energy expenditure (EE) and nonprotein respiratory quotient (RQnp) were measured by indirect calorimetry in 19 upper-body-obese (UBO) and 15 lower-body-obese (LBO) women with similar body mass index (BMI) and body fat percent. The measurements were performed in a respiration chamber on a predetermined physical activity program and a controlled diet. No differences between the UBO and LBO groups were found in 24-hour, daytime, and sleeping EE after adjustment for differences in fat-free mass (FFM). Furthermore, no group effect was observed in RQnp, but a positive correlation was found between RQnp and age. Despite the fact that an increased free fatty acid (FFA) turnover has been found in UBO subjects, the present study does not support the contention that upper-body obesity is accompanied by an increased lipid oxidation.

  20. Prognostic Significance of Initial Serum Albumin and 24 Hour Daily Protein Excretion before Treatment in Multiple Myeloma.

    PubMed

    Chen, Jia-Hong; Hsu, Shun-Neng; Huang, Tzu-Chuan; Wu, Yi-Ying; Lin, Chin; Chang, Ping-Ying; Chen, Yeu-Chin; Ho, Ching-Liang

    2015-01-01

    Renal failure is a common morbidity in multiple myeloma (MM). Although proteinuria has been increasingly reported in malignancies, it is not routinely used to refine risk estimates of survival outcomes in patients with MM. Here we aimed to investigate initial serum albumin and 24-hour daily protein excretion (24-h DPE) before treatment as prognostic factors in patients with MM. We conducted a retrospective analysis of 102 patients with myeloma who were ineligible for haematopoietic stem cell transplantation between October 2000 and December 2012. Initial proteinuria was assessed before treatment by quantitative analysis of 24-hour urine samples. The demographic and laboratory characteristics, survival outcome, and significance of pre-treatment 24-h DPE and albumin in the new staging system of MM were analyzed. Pre-treatment proteinuria (>300 mg/day) was present in 66 patients (64.7%). The optimal cut-off value of 24-h DPE before treatment was 500 mg/day. Analysis of the time-dependent area under the curve showed that the serum albumin and 24-h DPE before treatment were better than 24-h creatinine clearance rate and β2-microglobulin. A subgroup analysis showed that an initial excess proteinuria (24-h DPE ≥ 500 mg) was associated with poor survival status (17.51 vs. 34.24 months, p = 0.002). Furthermore, initial serum albumin was an independent risk factor on multivariate analysis (<2.8 vs. ≥ 2.8, hazard ratio = 0.486, p = 0.029). Using the A-DPE staging system, there was a significant survival difference among patients with stage I, II, and III MM (p < 0.001). Initial serum albumin and 24-h DPE before treatment showed significant prognostic factors in patients with MM, and the new A-DPE staging system may be utilized instead of the International Staging System. Its efficacy should be evaluated by further large prospective studies.

  1. Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs

    PubMed Central

    Guérin, Gaëtan; Bourges, Xavier; Turquier, Frédéric

    2014-01-01

    Purpose Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the SorbaFix™ absorbable fixation system with Bard™ Soft Mesh. Materials and methods Meshes (6 cm ×6 cm) were implanted in the preperitoneal space of swine. Samples were explanted 24 hours after surgery. Centered defects were created, and samples (either ten or eleven per fixation type) were loaded in a pressure chamber. For each sample, the pressure, the mesh displacement through the defect, and the measurements of the contact area were recorded. Results At all pressures tested, the ProGrip™ laparoscopic self-fixating mesh both exhibited a significantly lower displacement through the defect and retained a significantly higher percentage of its initial contact area than either the Bard™ Soft Mesh with Tisseel™ system or the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system. Dislocations occurred with the Bard™ Soft Mesh with Tisseel™ system and with the Bard™ Soft Mesh with SorbaFix™ absorbable fixation system at physiological pressure (,225 mmHg). No dislocation was recorded for the ProGrip™ laparoscopic self-fixating mesh. Conclusion At 24 hours after implantation, the mechanical fixation of the ProGrip™ laparoscopic self-fixating mesh was found to be significantly better than the fixation of the Tisseel™ system or the SorbaFix™ absorbable fixation system. PMID:25525396

  2. Ventricular Tachycardia in Fabry Disease Detected in a 50-Year-Old Woman during 14-Day Continuous Cardiac Monitoring

    PubMed Central

    Silva-Gburek, Jaime; Rochford, Laura; Hopkin, Robert

    2016-01-01

    Fabry disease is an X-linked lysosomal storage disorder. Female carriers were long thought to be asymptomatic; however, research has revealed the opposite. Cardiac conditions are the chief causes of death in women with Fabry disease. Although ventricular tachycardia has been reported in male patients with Fabry disease, it is not thought to be a frequent finding in females. We describe the case of a 50-year-old woman in whom we used 14-day continuous electrocardiographic monitoring to identify nonsustained ventricular tachycardia, after electrocardiograms and 24-hour Holter monitoring failed to detect the arrhythmia. A permanent implantable cardioverter-defibrillator relieved the patient's symptoms. We discuss why this case supports the need for more extensive electrophysiologic evaluation in women who have Fabry disease. PMID:28100976

  3. The prevalence of exercise-associated hyponatremia in 24-hour ultra-mountain bikers, 24-hour ultra-runners and multi-stage ultra-mountain bikers in the Czech Republic

    PubMed Central

    2014-01-01

    Background To assess the prevalence of exercise-associated hyponatremia (EAH) in two 24-hour mountain bike (MTB) (R1,R2), one 24-hour running (R3) and one multi-stage MTB (R4) races held in the Czech Republic in a cluster of four cross-sectional studies. Methods In 27 ultra-mountain bikers (ultra-MTBers), 12 ultra-runners, and 14 multi-stage MTBers, fluid intake, changes (Δ) in body mass, hematocrit, plasma volume, plasma [Na+], plasma [K+], plasma osmolality, urine [Na+], urine [K+], urine specific gravity, urine osmolality, K+/Na+ ratio in urine, transtubular potassium gradient and glomerular filtration rate were measured and calculated. The use of non-steroidal anti-inflammatory drugs and symptoms of EAH were recorded using post-race questionnaires. Results Of the 53 finishers, three (5.7%) developed post-race EAH, thereof one (3.7%) ultra-MTBer, one (8.3%) ultra-runner and one (7.1%) multi-stage MTBer. Plasma [Na+] decreased significantly (p < 0.001) only in R4. Urine osmolality (R1, R3, R4 p < 0.001; R2 p < 0.05) and glomerular filtration rate (p < 0.001) increased, and body mass decreased in all races (p < 0.05). Δ body mass was inversely related to the number of kilometers achieved (p < 0.001) in R2 where better ultra-MTBers tended to lose more weight. Δ body mass (p < 0.001) and %Δ body mass (p = 0.05) were positively related to lower post-race plasma [Na+] in R3 that was associated with increased loss in body mass. Fluid intake was positively related to race performance in R1 and R2 (R1: p = 0.04; R2: p = 0.01) where ultra-MTBers in R1 and R2 who drank more finished ahead of those who drank less. Post-race plasma [Na+] was negatively associated with race performance in ultra-MTBers in R2 (p < 0.05), similarly ultra-runners in R3 (p < 0.05) where finishers with more kilometres had lower post-race plasma [Na+]. Conclusions The prevalence of EAH in the Czech Republic was no higher compared to existing reports on ultra-endurance athletes in other countries

  4. Effect of an L- and T-Type Calcium Channel Blocker on 24-Hour Systolic Blood Pressure and Heart Rate in Hypertensive Patients

    PubMed Central

    Tsutsumi, Takeshi; Ebado, Mio; Takeyama, Youichi

    2012-01-01

    Background and Objectives The aim of this study was to evaluate the effects of an L- and T-type calcium channel blocker (CCB) on 24-hour systolic blood pressure (24-hour SBP) and heart rate (24-hour HR) profiles in essential hypertensive patients. Subjects and Methods Thirty-seven consecutive patients were enrolled in this study. The 24-hour SBP and HR were recorded before and after treatment with efonidipine (L- and T-type CCB, 40 mg), after waking. Changes in 24-hour SBP and HR and the diurnal to nocturnal SBP ratio were measured. The best-fit curves of changes in SBP and HR were depicted using a periodic function. Results The mean 24-hour SBP and HR decreased significantly after treatment. The diurnal to nocturnal SBP ratio in dipper-type hypertension cases decreased from 16.7±6.1% to 8.3±9.8% (p<0.05), whereas in non-dipper hypertension cases, it increased from 2.3±2.9% to 7.7±5.1% (p<0.01). The antihypertensive effect was minimal at 5.0 hours after drug administration and it slowly recovered at a constant rate (2.1 mm Hg/h) over 12 hours in dipper cases. The median 24-hour changes in HR in the dipper and non-dipper cases were -2.3/min and -5.4/min, respectively. A continuous reduction in the change in HR was seen from 3.5 to 23 hours after drug administration. Conclusion The antihypertensive action of efonidipine was characterized by a slow recovery of the SBP decrease at a constant rate (2.1 mm Hg/h) and a non-administration time dependent reduction in 24-hour HR. PMID:22563335

  5. Mean 24-hours sympathetic nervous system activity decreases during head-down tilted bed rest but not during microgravity

    NASA Astrophysics Data System (ADS)

    Christensen, Nj; Heer, M.; Ivanova, K.; Norsk, P.

    Sympathetic nervous system activity is closely related to gravitational stress in ground based experiments. Thus a high activity is present in the standing-up position and a very low activity is observed during acute head-out water immersion. Adjustments in sympathetic activity are necessary to maintain a constant blood pressure during variations in venous return. Head-down tilted bed rest is applied as a model to simulate changes observed during microgravity. The aim of the present study was to test the hypothesis that mean 24-hours sympathetic activity was low and similar during space flight and in ground based observation obtained during long-term head-down tilted bed rest. Forearm venous plasma noradrenaline was measured by a radioenzymatic technique as an index of muscle sympathetic activity and thrombocyte noradrenaline and adrenaline were measured as indices of mean 24-hours sympathoadrenal activity. Previous results have indicated that thrombocyte noradrenaline level has a half-time of 2 days. Thus to reflect sympathetic activity during a specific experiment the study period must last for at least 6 days and a sample must be obtained within 12 hours after the experiment has ended. Ten normal healthy subjects were studied before and during a 14 days head-down tilted bed rest as well as during an ambulatory study period of a similar length. The whole experiment was repeated while the subjects were on a low calorie diet. Thrombocyte noradrenaline levels were studied in 4 cosmonauts before and within 12 hours after landing after more than 7 days in flight. Thrombocyte noradrenaline decreased markedly during the head-down tilted bed rest (p<0.001), whereas there were no significant changes in the ambulatory study. Plasma noradrenaline decreased in the adaptation period but not during the intervention. During microgravity thrombocyte noradrenaline increased in four cosmonauts and the percentage changes were significantly different in cosmonauts and in subjects

  6. Long-Term Continuous Ambulatory ECG Monitors and External Cardiac Loop Recorders for Cardiac Arrhythmia: A Health Technology Assessment

    PubMed Central

    Kabali, Conrad; Xie, Xuanqian; Higgins, Caroline

    2017-01-01

    Background Ambulatory electrocardiography (ECG) monitors are often used to detect cardiac arrhythmia. For patients with symptoms, an external cardiac loop recorder will often be recommended. The improved recording capacity of newer Holter monitors and similar devices, collectively known as longterm continuous ambulatory ECG monitors, suggests that they will perform just as well as, or better than, external loop recorders. This health technology assessment aimed to evaluate the effectiveness, cost-effectiveness, and budget impact of longterm continuous ECG monitors compared with external loop recorders in detecting symptoms of cardiac arrhythmia. Methods Based on our systematic search for studies published up to January 15, 2016, we did not identify any studies directly comparing the clinical effectiveness of longterm continuous ECG monitors and external loop recorders. Therefore, we conducted an indirect comparison, using a 24-hour Holter monitor as a common comparator. We used a meta-regression model to control for bias due to variation in device-wearing time and baseline syncope rate across studies. We conducted a similar systematic search for cost-utility and cost-effectiveness studies comparing the two types of devices; none were found. Finally, we used historical claims data (2006–2014) to estimate the future 5-year budget impact in Ontario, Canada, of continued public funding for both types of longterm ambulatory ECG monitors. Results Our clinical literature search yielded 7,815 non-duplicate citations, of which 12 cohort studies were eligible for indirect comparison. Seven studies assessed the effectiveness of longterm continuous monitors and five assessed external loop recorders. Both types of devices were more effective than a 24-hour Holter monitor, and we found no substantial difference between them in their ability to detect symptoms (risk difference 0.01; 95% confidence interval −0.18, 0.20). Using GRADE for network meta-analysis, we evaluated the

  7. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome

    PubMed Central

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support. PMID:27398166

  8. Dietary quality varies according to data collection instrument: a comparison between a food frequency questionnaire and 24-hour recall.

    PubMed

    Rodrigues, Paulo Rogério Melo; de Souza, Rita Adriana Gomes; De Cnop, Mara Lima; Monteiro, Luana Silva; Coura, Camila Pinheiro; Brito, Alessandra Page; Pereira, Rosangela Alves

    2016-02-01

    The objective of this study was to assess the agreement between the Brazilian Healthy Eating Index - Revised (BHEI-R), estimated by a food frequency questionnaire (FFQ) and multiple 24-hour recalls (24h-R). The Wilcoxon paired test, partial correlations (PC), intraclass correlation coefficient (ICC), and Bland-Altman method were used. The total BHEI-R scores and its components ("total fruits", "whole fruits", "total vegetables", "integral cereals", "saturated fat", "sodium", and "energy intake derived from solid fat, added sugar, and alcoholic beverages") were statistically different, with the ICC and PC indicating poor concordance and correlation. The mean concordance estimated for the total BHEI-R and its components varied from 68% for "integral cereals" to 147% for "whole fruits". The suitable concordance limits were violated for most of the components of the BHEI-R. Poor concordance was observed between the BHEI-R estimated by the FFQ and by multiple 24h-R, which indicated a strong reliability of the BHEI-R on the instrument used to collect information on food consumption.

  9. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome.

    PubMed

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support.

  10. Lessons from Studies to Evaluate an Online 24-Hour Recall for Use with Children and Adults in Canada.

    PubMed

    Kirkpatrick, Sharon I; Gilsing, Anne M; Hobin, Erin; Solbak, Nathan M; Wallace, Angela; Haines, Jess; Mayhew, Alexandra J; Orr, Sarah K; Raina, Parminder; Robson, Paula J; Sacco, Jocelyn E; Whelan, Heather K

    2017-01-31

    With technological innovation, comprehensive dietary intake data can be collected in a wide range of studies and settings. The Automated Self-Administered 24-hour (ASA24) Dietary Assessment Tool is a web-based system that guides respondents through 24-h recalls. The purpose of this paper is to describe lessons learned from five studies that assessed the feasibility and validity of ASA24 for capturing recall data among several population subgroups in Canada. These studies were conducted within a childcare setting (preschool children with reporting by parents), in public schools (children in grades 5-8; aged 10-13 years), and with community-based samples drawn from existing cohorts of adults and older adults. Themes emerged across studies regarding receptivity to completing ASA24, user experiences with the interface, and practical considerations for different populations. Overall, we found high acceptance of ASA24 among these diverse samples. However, the ASA24 interface was not intuitive for some participants, particularly young children and older adults. As well, technological challenges were encountered. These observations underscore the importance of piloting protocols using online tools, as well as consideration of the potential need for tailored resources to support study participants. Lessons gleaned can inform the effective use of technology-enabled dietary assessment tools in research.

  11. Global empirical model of TEC response to geomagnetic activity: Short-term (24 hours ahead) prediction model

    NASA Astrophysics Data System (ADS)

    Andonov, Borislav

    2013-04-01

    A global empirical model of the rTEC=(TECobs-TECmed)/TECmed depending on the geomagnetic activity (described by the Kp-index) and at a given moment is built by using global TEC data for full 13 years between 1999 and 2011.The data are downloaded from the CODE (Center for Orbit Determination in Europe) database in the Astronomical Institute, University of Bern. By using a 2D cross-correlation analysis it is found that the ionospheric response to the geomagnetic activity revealed both positive and negative phases of the response. The both phases of the ionospheric response have different duration and time delay with respect to the geomagnetic storm. It was found that these two parameters of the ionospheric response depend on the season, geographical/geomagnetic coordinates and local time. The rTEC response is represented by 2D (longitude-time) sine waves with different zonal wavenumbers and periods being harmonics of the diurnal period. The input data for the current and predicted geomagnetic activity are obtained from the MAK model developed in NIGGG-BAS, which uses the solar wind measurements from the ACE satellite. The background condition is defined by the recent CODE TEC maps. For each current hour the model provides predicted global TEC maps in geographic frame for the next 24 hours.

  12. Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep.

    PubMed

    Tremblay, Mark S; Carson, Valerie; Chaput, Jean-Philippe; Connor Gorber, Sarah; Dinh, Thy; Duggan, Mary; Faulkner, Guy; Gray, Casey E; Gruber, Reut; Janson, Katherine; Janssen, Ian; Katzmarzyk, Peter T; Kho, Michelle E; Latimer-Cheung, Amy E; LeBlanc, Claire; Okely, Anthony D; Olds, Timothy; Pate, Russell R; Phillips, Andrea; Poitras, Veronica J; Rodenburg, Sophie; Sampson, Margaret; Saunders, Travis J; Stone, James A; Stratton, Gareth; Weiss, Shelly K; Zehr, Lori

    2016-06-01

    Leaders from the Canadian Society for Exercise Physiology convened representatives of national organizations, content experts, methodologists, stakeholders, and end-users who followed rigorous and transparent guideline development procedures to create the Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep. These novel guidelines for children and youth aged 5-17 years respect the natural and intuitive integration of movement behaviours across the whole day (24-h period). The development process was guided by the Appraisal of Guidelines for Research Evaluation (AGREE) II instrument and systematic reviews of evidence informing the guidelines were assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Four systematic reviews (physical activity, sedentary behaviour, sleep, integrated behaviours) examining the relationships between and among movement behaviours and several health indicators were completed and interpreted by expert consensus. Complementary compositional analyses were performed using Canadian Health Measures Survey data to examine the relationships between movement behaviours and health indicators. A stakeholder survey was employed (n = 590) and 28 focus groups/stakeholder interviews (n = 104) were completed to gather feedback on draft guidelines. Following an introductory preamble, the guidelines provide evidence-informed recommendations for a healthy day (24 h), comprising a combination of sleep, sedentary behaviours, light-, moderate-, and vigorous-intensity physical activity. Proactive dissemination, promotion, implementation, and evaluation plans have been prepared in an effort to optimize uptake and activation of the new guidelines. Future research should consider the integrated relationships among movement behaviours, and similar integrated guidelines for other age groups should be developed.

  13. The 24-hour shelf-life of cytapheresis platelet concentrates stored in polyvinyl chloride containers should be extended only with caution.

    PubMed

    Strauss, R G; Snyder, E L; Eckermann, I; Stewart, L

    1987-01-01

    A recent publication suggested that the 24-hour allowable shelf-life of apheresis platelet concentrates collected by open-system techniques be extended to 48 hours because platelets collected in this fashion usually remain sterile for that length of time. The current studies, however, show that the quality of platelet concentrates deteriorates rapidly after storage for more than 24 hours in the relatively small-volume, polyvinyl chloride containers of currently marketed, open-system software, as evidenced by the falling pH, the disintegration of platelets, and the inability of platelets to recover from hypotonic shock. Platelets were markedly defective within 48 hours. Thus, it seems unwise to extend the shelf-life of such platelet concentrates beyond 24 hours solely because they are likely to remain sterile. Collection techniques and software must also be modified to ensure satisfactory platelet quality before the period of storage should be extended.

  14. Segment clustering methodology for unsupervised Holter recordings analysis

    NASA Astrophysics Data System (ADS)

    Rodríguez-Sotelo, Jose Luis; Peluffo-Ordoñez, Diego; Castellanos Dominguez, German

    2015-01-01

    Cardiac arrhythmia analysis on Holter recordings is an important issue in clinical settings, however such issue implicitly involves attending other problems related to the large amount of unlabelled data which means a high computational cost. In this work an unsupervised methodology based in a segment framework is presented, which consists of dividing the raw data into a balanced number of segments in order to identify fiducial points, characterize and cluster the heartbeats in each segment separately. The resulting clusters are merged or split according to an assumed criterion of homogeneity. This framework compensates the high computational cost employed in Holter analysis, being possible its implementation for further real time applications. The performance of the method is measure over the records from the MIT/BIH arrhythmia database and achieves high values of sensibility and specificity, taking advantage of database labels, for a broad kind of heartbeats types recommended by the AAMI.

  15. Effect of aging on 24-hour changes in dopamine and serotonin turnover and amino acid and somatostatin contents of rat corpus striatum.

    PubMed

    Esquifino, Ana I; Cano, Pilar; Chacon, Fernando; Reyes Toso, Carlos F; Cardinali, Daniel P

    2002-01-01

    This study examined the 24-hour changes in a number of transmitters in the corpus striatum of young and middle-aged male Wistar rats. The contents of excitatory amino acids (glutamate, aspartate) and inhibitory amino acids (gamma-aminobutyric acid, GABA; taurine, glycine) and of somatostatin were measured in 2-month- and 18- to 20-month-old rats killed at six different time points along the 24-hour cycle. The striatal serotonin and dopamine turnover was also measured. Both young and middle-aged rats showed significant 24-hour variations in striatal glutamate and aspartate contents; only in young rats these variations fitted a cosine function, with acrophase during the first part of rest span. Mesor values of striatal excitatory amino acid contents were lowest in middle-aged rats. Significant 24-hour variations in striatal contents of GABA, taurine, and glycine occurred in young rats, while only striatal GABA exhibited 24-hour changes in middle- aged rats (acrophases during the first part of rest span). For every inhibitory transmitter, the mesor values in middle-aged rats were significantly lower than in young rats. The 24-hour variation of the striatal somatostatin content showed acrophase during the first part of rest span, mesor values and amplitude being lowest in middle-aged rats. Aging rats exhibited significantly higher mesor values of striatal serotonin turnover (34% increase) and lower mesor values of dopamine turnover (69% decrease) than their younger counterparts. Some of the circadian modifications of motor function seen in aging rats could be related to the striatal transmitter changes reported herein.

  16. The relatively poor correlation between random and 24-hour urine protein excretion in patients with biopsy-proven glomerular diseases.

    PubMed

    Hogan, Marie C; Reich, Heather N; Nelson, Peter J; Adler, Sharon G; Cattran, Daniel C; Appel, Gerald B; Gipson, Debbie S; Kretzler, Matthias; Troost, Jonathan P; Lieske, John C

    2016-11-01

    Random urine protein creatinine ratios are used to estimate 24-hour urine protein excretion, which is considered a diagnostic gold standard. However, few studies are available of the sensitivity and specificity of this estimation in patients with glomerular proteinuria. To clarify this, we measured the urine protein and creatinine centrally in random and 24-hour urine collections at biopsy and longitudinally every 6 months in individuals participating in the Nephrotic Syndrome Study Network (NEPTUNE) cohort with glomerular disease. In the initial developmental cohort, 302 patients had same day random and 24-hour samples with a total of 827 paired measurements across all visits. The protein excretion (g/day) was higher in adult than pediatric patients. The correlation between the random urine protein creatinine ratio and 24-hour urine protein excretion was moderate in both groups (r of 0.60 and 0.67, respectively). However, the log10 transformation of values strengthened correlations in both groups (r of 0.85 and 0.82, respectively). Associations were moderately stronger among obese patients. Prediction equations were developed and validated in 232 unique cases from NEPTUNE (R(2) of 0.65). Thus, in patients with glomerular disease and proteinuria, the urine protein creatinine ratio correlates only moderately with 24-hour urine protein excretion. However an estimating equation was developed to derive 24-hour urine protein excretion from random urine protein creatinine ratio values with improved precision. The long-term prognostic value of log10-transformed random protein creatinine ratios values requires future study.

  17. Investigations into the source of two fungicides measured in the air for 24 hours following application to a cereal crop.

    PubMed

    Ellis, M C Butler; Lane, A G; O'Sullivan, C M; Miller, P C H

    2009-01-01

    Airborne pesticides can be detected near to recently-treated arable fields for a period of days following the application. Identifying the source of such pesticides is important in developing predictive models for use in exposure and risk assessments. Previous work showed levels of pesticide in the air that were higher than expected for a low-vapour-pressure active ingredient, epoxiconazole, and comparable with an active ingredient of a significantly higher vapour pressure, fenpropidin. It was possible that the measured concentrations could be attributed to 'dust' particles emitted from the crop, either biological material contaminated with pesticide or solid dried deposits of active ingredient and other formulation components. A second experiment was therefore undertaken to measure airborne concentrations of the same active ingredients and to determine whether some or all of the measured airborne pesticide could be attributed to particles, using a Marple personal cascade impactor, which collects particles in the range 0.3 - 50 microm. Such samplers are not optimised to give good sampling efficiencies under the proposed field conditions, so some initial tests were undertaken in the Silsoe wind tunnel to assess its ability to sample particles in an air flow. In the subsequent field trial, a 192 m square plot in a commercially established winter cereal crop was sprayed with a tank mix of commercial formulations of epoxiconazole and fenpropidin. Measurements of airborne pesticides were made for 24 hours following the application with suction samplers attached to tenax tubes to evaluate vapour concentrations and with the cascade impactor to determine whether contaminated airborne particles were present. The concentrations of pesticide measured with the tenax tubes were significantly higher than the particulate component detected on the cascade impactor plates and it is therefore it was very unlikely that there was a significant contribution from pesticide

  18. Bath water contamination with Legionella and nontuberculous mycobacteria in 24-hour home baths, hot springs, and public bathhouses of Nagano Prefecture, Japan.

    PubMed

    Kobayashi, Michiko; Oana, Kozue; Kawakami, Yoshiyuki

    2014-01-01

    Bath water samples were collected from 116 hot springs, 197 public bathhouses, and 38 24-hour home baths in Nagano Prefecture, Japan, during the period of April 2009 to November 2011, for determining the presence and extent of contamination with Legionella and nontuberculous mycobacteria. Cultures positive for Legionella were observed in 123 of the 3,314 bath water samples examined. The distribution and abundance of Legionella and/or combined contamination with Legionella and nontuberculous mycobacteria were investigated to clarify the contamination levels. The abundance of Legionella was demonstrated to correlate considerably with the levels of combined contamination with Legionella and nontuberculous mycobacteria. Legionella spp. were obtained from 61% of the water samples from 24-hour home baths, but only from 3% of the samples from public bathhouses and hot springs. This is despite the fact that a few outbreaks of Legionnaires' disease in Nagano Prefecture as well as other regions of Japan have been traced to bath water contamination. The comparatively higher rate of contamination of the 24-hour home baths is a matter of concern. It is therefore advisable to routinely implement good maintenance of the water basins, particularly of the 24-hour home baths.

  19. 49 CFR 375.607 - What must I do if I am able to tender a shipment for final delivery more than 24 hours before a...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false What must I do if I am able to tender a shipment for final delivery more than 24 hours before a specified date? 375.607 Section 375.607 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL...

  20. Effect of one week of CPAP treatment of obstructive sleep apnoea on 24-hour profiles of glucose, insulin and counter-regulatory hormones in type 2 diabetes.

    PubMed

    Mokhlesi, Babak; Grimaldi, Daniela; Beccuti, Guglielmo; Van Cauter, Eve

    2017-03-01

    Studies examining the impact of CPAP treatment on glycaemic control have yielded conflicting results, partly because of insufficient nightly CPAP use. We examined the 24-hour profiles of glucose, insulin and counter-regulatory hormones in 12 subjects with type 2 diabetes and OSA before and after 1 week of effective in-laboratory CPAP therapy over an entire 8-hour night thus ensuring optimal CPAP compliance. Blood samples were collected every 15 to 30 minutes for 24 hours under controlled conditions. The 24-hour mean glucose decreased from 153.2 ± 33.0 to 139.7 ± 24.2 mg/dL with CPAP (-13.5 ± 13.5 mg/dL; P = .005) without change in insulin levels. Morning fasting glucose levels decreased by 14.6 ± 3 mg/dL (P = .001) and the dawn phenomenon decreased by 7.8 ± 9.8 mg/dL (P = .019). CPAP treatment decreased norepinephrine levels while the 24-hour profiles of growth hormone and cortisol remained unchanged. In conclusion, 1 week of effective treatment of OSA over an entire 8-hour night results in a clinically significant improvement in glycaemic control via an amelioration of evening fasting glucose metabolism and a reduction in the dawn phenomenon, a late-night glucose increase that is not adequately treated by oral medications. Clinical Trials Information: ClinicalTrials.gov Identifier: NCT01136785.

  1. The effect of low level radiofrequency electromagnetic radiation on the excretion rates of stress hormones in operators during 24-hour shifts.

    PubMed

    Vangelova, K; Israel, M; Mihaylov, S

    2002-06-01

    The aim of the study was to investigate the effect of long term exposure to low level radiofrequency (RF) electromagnetic (EM) radiation on the excretion rates of stress hormones in satellite station operators during 24-hour shifts. Twelve male operators at a satellite station for TV communications and space research were studied during 24-hour shifts. Dosimetric evaluation of the exposure was carried out and showed low level exposure with specific absorption of 0.1127 J.kg-1. A control group of 12 unexposed male operators with similar job task and the same shift system were studied, too. The 11-oxycorticosteroids (11-OCS), adrenaline and noradrenaline were followed by spectrofluorimetric methods on 3-hour intervals during the 24-hour shifts. The data were analyzed by tests for interindividual analysis, Cosinor analysis and analysis of variance (ANOVA). Significant increase in the 24-hour excretion of 11-OCS and disorders in its circadian rhythm, manifested by increase in the mesor, decrease in the amplitude and shift in the acrophase were found in the exposed operators. The changes in the excretion rates of the catecholamines were significant and showed greater variability of both variables. The long term effect of the exposure to low-level RF EM radiation evoked pronounced stress reaction with changes in the circadian rhythm of 11-OCS and increased variability of catecholamines secretion. The possible health hazards associated with observed alteration in the stress system need to be clarified by identification of their significance and prognostic relevance.

  2. Validation of the automated self-administered 24-hour dietary recall for children (ASA24-Kids) among 9- to 11-year-old youth

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our purpose was to validate ASA24-Kids-2012, a self-administered web-based 24-hour dietary recall (24hDR) among 9- to 11-year-old children. Sixty-nine children in two sites participated in the study. In one site, trained staff observed and recorded types and portions of foods and drinks consumed by ...

  3. Characterization of pulmonary protein profiles in response to zinc oxide nanoparticles in mice: a 24-hour and 28-day follow-up study

    PubMed Central

    Pan, Chih-Hong; Chuang, Kai-Jen; Chen, Jen-Kun; Hsiao, Ta-Chih; Lai, Ching-Huang; Jones, Tim P; BéruBé, Kelly A; Hong, Gui-Bing; Ho, Kin-Fai; Chuang, Hsiao-Chi

    2015-01-01

    Although zinc oxide nanoparticles (ZnONPs) are recognized to cause systemic disorders, little is known about the mechanisms that underlie the time-dependent differences that occur after exposure. The objective of this study was to investigate the mechanistic differences at 24 hours and 28 days after the exposure of BALB/c mice to ZnONPs via intratracheal instillation. An isobaric tag for the relative and absolute quantitation coupled with liquid chromatography/tandem mass spectrometry was used to identify the differential protein expression, biological processes, molecular functions, and pathways. A total of 18 and 14 proteins displayed significant changes in the lung tissues at 24 hours and 28 days after exposure, respectively, with the most striking changes being observed for S100-A9 protein. Metabolic processes and catalytic activity were the main biological processes and molecular functions, respectively, in the responses at the 24-hour and 28-day follow-up times. The glycolysis/gluconeogenesis pathway was continuously downregulated from 24 hours to 28 days, whereas detoxification pathways were activated at the 28-day time-point after exposure. A comprehensive understanding of the potential time-dependent effects of exposure to ZnONPs was provided, which highlights the metabolic mechanisms that may be important in the responses to ZnONP. PMID:26251593

  4. Identifying nutrients that are under-reported by an automated 24-hour dietary recall method in overweight and obese women after weight loss

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Underreporting of energy intake by 15-50% is a common problem in dietary assessment. Evidence suggests overweight/obese respondents are more likely to under-report than normal weight. This study compared Automated Self-Administered 24-hour recall (ASA24)-reported dietary intake to true intake in ove...

  5. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBONPAK X SOLID ADSORBENT WITH THEMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDIES

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hours onto the graphitic adsorbent Carbopack X contained in a stainless steel tube badge (6.3 mm OD, 5 mm ID, and 90 mm in length) with analysis by thermal desorption/GC/MS has been evaluated in controlled tests. A test matrix of 42 tr...

  6. Characterization of pulmonary protein profiles in response to zinc oxide nanoparticles in mice: a 24-hour and 28-day follow-up study.

    PubMed

    Pan, Chih-Hong; Chuang, Kai-Jen; Chen, Jen-Kun; Hsiao, Ta-Chih; Lai, Ching-Huang; Jones, Tim P; BéruBé, Kelly A; Hong, Gui-Bing; Ho, Kin-Fai; Chuang, Hsiao-Chi

    2015-01-01

    Although zinc oxide nanoparticles (ZnONPs) are recognized to cause systemic disorders, little is known about the mechanisms that underlie the time-dependent differences that occur after exposure. The objective of this study was to investigate the mechanistic differences at 24 hours and 28 days after the exposure of BALB/c mice to ZnONPs via intratracheal instillation. An isobaric tag for the relative and absolute quantitation coupled with liquid chromatography/tandem mass spectrometry was used to identify the differential protein expression, biological processes, molecular functions, and pathways. A total of 18 and 14 proteins displayed significant changes in the lung tissues at 24 hours and 28 days after exposure, respectively, with the most striking changes being observed for S100-A9 protein. Metabolic processes and catalytic activity were the main biological processes and molecular functions, respectively, in the responses at the 24-hour and 28-day follow-up times. The glycolysis/gluconeogenesis pathway was continuously downregulated from 24 hours to 28 days, whereas detoxification pathways were activated at the 28-day time-point after exposure. A comprehensive understanding of the potential time-dependent effects of exposure to ZnONPs was provided, which highlights the metabolic mechanisms that may be important in the responses to ZnONP.

  7. Value of random urinary homovanillic acid and vanillylmandelic acid levels in the diagnosis and management of patients with neuroblastoma: comparison with 24-hour urine collections.

    PubMed

    Tuchman, M; Morris, C L; Ramnaraine, M L; Bowers, L D; Krivit, W

    1985-02-01

    Urinary homovanillic acid (HVA) and vanillylmandelic acid (VMA) levels were determined in random samples and in 24-hour collections from 13 patients with neuroblastoma and 22 patients without neuroblastoma. Random sample levels were compared with levels in 24-hour collections and showed a positive correlation of 95% for HVA (N = 59) and 93% for VMA (N = 52). No false positives or false negatives occurred using random samples for diagnosis. Nonneuroblastoma (normal) HVA (N = 126) and VMA (N = 119) levels are reported for different age groups. Sequential random HVA and VMA determinations in patients with neuroblastoma during and after therapy are shown. Random urinary HVA and VMA levels are shown to be adequate for utilization in the diagnosis of neuroblastoma and sequential determinations of random HVA and VMA are shown to be helpful in the follow-up of those patients.

  8. In vitro study of 24-hour and 30-day shear bond strengths of three resin-glass ionomer cements used to bond orthodontic brackets.

    PubMed

    Lippitz, S J; Staley, R N; Jakobsen, J R

    1998-06-01

    Interest in using composite resin-glass ionomer hybrid cements as orthodontic bracket adhesives has grown because of their potential for fluoride release. The purpose of this pilot study was to compare shear bond strengths of three resin-glass ionomer cements (Advance, Fuji Duet, Fuji Ortho LC) used as bracket adhesives with a composite resin 24 hours and 30 days after bonding. The amount of adhesive remaining on the debonded enamel surface was scored for each adhesive. Mesh-backed stainless-steel brackets were bonded to 100 extracted human premolars, which were stored in artificial saliva at 37 degrees C until being tested to failure in a testing machine. The hybrid cements, with one exception, had bond strengths similar to those of the composite resin at 24 hours and 30 days. Fuji Ortho LC had significantly lower bond strengths (ANOVA p < or = 0.05) than the other adhesives at 24 hours and 30 days when it was bonded to unetched, water-moistened enamel. Adhesive-remnant scores were similar for all cements, except for cement Fuji Ortho LC when it was bonded to unetched enamel. The resin-glass ionomer cements we tested appear to have bond strengths suitable for routine use as orthodontic bracket-bonding adhesives.

  9. Deconvolution of insulin secretion, insulin hepatic extraction post-hepatic delivery rates and sensitivity during 24-hour standardized meals: time course of glucose homeostasis in leptin replacement treatment.

    PubMed

    Andreev, V P; Paz-Filho, G; Wong, M-L; Licinio, J

    2009-02-01

    Minimally invasive methodology, mathematical model, and software for analysis of glucose homeostasis by deconvolution of insulin secretion, hepatic extraction, post-hepatic delivery, and sensitivity from 24-hour standardized meals test have been developed and illustrated by the study of glucose homeostasis of a genetically based leptin-deficient patient before and after leptin replacement treatment. The only genetically leptin-deficient adult man identified in the world was treated for 24 months with recombinant methionyl human leptin. Blood was collected every 7 minutes for 24 hours, with standardized meals consumed during the 4 visits: at baseline, one-week, 18-months, and 24-months after initiation of the treatment. Concentrations of insulin, C-peptide, and plasma glucose were measured. Insulin secretion was obtained by deconvolution of C-peptide data. Hepatic insulin extraction was determined based on our modifications of the insulin kinetics model . Insulin sensitivity for each of the four meals was calculated by using the minimal glucose model approach. Hepatic extraction of insulin was the first element of glucose homeostasis to respond to leptin replacement treatment and increased 2-fold after one week of treatment. Insulin secretion and delivery rates decreased more than 2-fold and insulin sensitivity increased 10-fold after 24 months of treatment. Computer programs for analysis of 24-hour insulin secretion, extraction, delivery, and action are available upon request.

  10. Effects of transdermal scopolamine, alone or in combination with cimetidine, on total 24 hour gastric acid secretion in patients with duodenal ulcer.

    PubMed Central

    Richardson, C T; Feldman, M

    1986-01-01

    Transdermal scopolamine is an antimuscarinic preparation approved for use in the United States for prevention of motion sickness. A recent study using this drug (0.5 mg/patch) suggested that enough scopolamine was absorbed through the skin to reduce basal gastric acid secretion in patients with duodenal ulcer. We have compared the effect of transdermal scopolamine and oral cimetidine (400 mg twice daily) in seven men with chronic duodenal ulcer, both alone and in combination, on acid secretion throughout an entire 24 hour period in a placebo-controlled, randomised, double blinded cross over study. The effect of these drugs on basal, interprandial, and nocturnal gastric juice volume and hydrogen ion concentration also was measured. Transdermal scopolamine had no significant effect on mean 24 hour acid secretion (placebo, 409.4 mmol/day; scopolamine, 364.0 mmol/day) nor did it have a significant effect on gastric juice volume or hydrogen ion concentration. The combination of transdermal scopolamine plus cimetidine was not more effective than cimetidine alone in reducing total 24 hour acid secretion (mean, 231.8 versus 235.3 mmol/day) nor in reducing gastric juice volume or hydrogen ion concentration. PMID:3804025

  11. Correlation of 24-Hour Blood Pressure and Heart Rate Variability to Renal Function Parameters in Hypertensive Patients. The Effect of Smoking.

    PubMed

    Liakos, Charalampos I; Karpanou, Eva A; Markou, Maria I; Grassos, Charalampos A; Vyssoulis, Gregory P

    2015-12-01

    Intrarenal hemodynamics depend on blood pressure (BP), heart rate (HR), and smoking. Although BP levels have been associated with kidney function, the effect of HR levels, BP, and HR variability on renal function are less well clarified. This cross-sectional study sought to determine the association of 24-hour BP and HR variability with kidney function in hypertensive patients, stratified by smoking. The study comprised 9600 nondiabetic, never-treated hypertensive individuals without evident renal impairment examined from 1985 to 2014 (aged 53.3±13.4 years, 55.3% males). The 24-hour systolic BP (SBP) and HR variability were estimated via their coefficient of variation (CV =standard deviation×100/mean value) derived from ambulatory recording. The CV SBP-to-CV HR ratio (CV R) was used as a marker of the interplay between 24-hour SBP and HR variability. Renal function was estimated via 24-hour urine creatinine clearance (CrCl), estimated glomerular filtration rate (eGFR), albumin-to-creatinine ratio (ACR), and 24-hour urine α1 -microglobulin. After adjustment for age, sex, and smoking, CV SBP was found to be weakly correlated to eGFR (r=-0.017, P=.1) and somewhat more strongly to CrCl, ACR, and α1 -microglobulin (r=-0.032, 0.072, and 0.065; P=.002, <.001 and <.001, respectively). CV HR was much better related to renal function, with stronger adjusted correlations to CrCl, eGFR, ACR, and α1 -microglobulin (r=0.185, 0.134, -0.306, -0.247; all P<.001, respectively). CV R also showed equally good adjusted correlations (r=-0.175, -0.125, 0.336, 0.262; all P<.001, respectively). Most adjusted correlations for CV HR and CV R were even better in smokers (r=0.213, 0.158, -0.332, -0.272 and -0.183, -0.118, 0.351, 0.275, respectively; all P<.001). CV HR and CV R emerge as better related to kidney function than CV SBP, especially in smokers. The correlation of CV HR and CV SBP to renal function is inverse to each other. ACR and α1 -microglobulin are better related to

  12. Cross-Sectional Study of 24-Hour Urinary Electrolyte Excretion and Associated Health Outcomes in a Convenience Sample of Australian Primary Schoolchildren: The Salt and Other Nutrients in Children (SONIC) Study Protocol

    PubMed Central

    Baxter, Janet R; Campbell, Karen J; Riddell, Lynn J; Rigo, Manuela; Liem, Djin Gie; Keast, Russell S; He, Feng J; Nowson, Caryl A

    2015-01-01

    Background Dietary sodium and potassium are involved in the pathogenesis of cardiovascular disease. Data exploring the cardiovascular outcomes associated with these electrolytes within Australian children is sparse. Furthermore, an objective measure of sodium and potassium intake within this group is lacking. Objective The primary aim of the Salt and Other Nutrient Intakes in Children (“SONIC”) study was to measure sodium and potassium intakes in a sample of primary schoolchildren located in Victoria, Australia, using 24-hour urine collections. Secondary aims were to identify the dietary sources of sodium and potassium, examine the association between these electrolytes and cardiovascular risk factors, and assess children’s taste preferences and saltiness perception of manufactured foods. Methods A cross-sectional study was conducted in a convenience sample of schoolchildren attending primary schools in Victoria, Australia. Participants completed one 24-hour urine collection, which was analyzed for sodium, potassium, and creatinine. Completeness of collections was assessed using collection time, total volume, and urinary creatinine. One 24-hour dietary recall was completed to assess dietary intake. Other data collected included blood pressure, body weight, height, waist and hip circumference. Children were also presented with high and low sodium variants of food products and asked to discriminate salt level and choose their preferred variant. Parents provided demographic information and information on use of discretionary salt. Descriptive statistics will be used to describe sodium and potassium intakes. Linear and logistic regression models with clustered robust standard errors will be used to assess the association between electrolyte intake and health outcomes (blood pressure and body mass index/BMI z-score and waist circumference) and to assess differences in taste preference and discrimination between high and low sodium foods, and correlations between

  13. Evaluating acellular versus cellular perfusate composition during prolonged ex vivo lung perfusion after initial cold ischaemia for 24 hours.

    PubMed

    Becker, Simon; Steinmeyer, Jasmin; Avsar, Murat; Höffler, Klaus; Salman, Jawad; Haverich, Axel; Warnecke, Gregor; Ochs, Matthias; Schnapper, Anke

    2016-01-01

    Normothermic ex vivo lung perfusion (EVLP) has developed as a powerful technique to evaluate particularly marginal donor lungs prior to transplantation. In this study, acellular and cellular perfusate compositions were compared in an identical experimental setting as no consensus has been reached on a preferred technique yet. Porcine lungs underwent EVLP for 12 h on the basis of an acellular or a cellular perfusate composition after 24 h of cold ischaemia as defined organ stress. During perfusion, haemodynamic and respiratory parameters were monitored. After EVLP, the lung condition was assessed by light and transmission electron microscopy. Aerodynamic parameters did not show significant differences between groups and remained within the in vivo range during EVLP. Mean oxygenation indices were 491 ± 39 in the acellular group and 513 ± 53 in the cellular group. Groups only differed significantly in terms of higher pulmonary artery pressure and vascular resistance in the cellular group. Lung histology and ultrastructure were largely well preserved after prolonged EVLP and showed only minor structural alterations which were similarly present in both groups. Prolonged acellular and cellular EVLP for 12 h are both feasible with lungs prechallenged by ischaemic organ stress. Physiological and ultrastructural analysis showed no superiority of either acellular or cellular perfusate composition.

  14. [A validation of the data obtained with the simultaneous recording of blood pressure and the 24-hour electrocardiogram].

    PubMed

    Germanò, G; Caparra, A; Valentino, S; Coia, F; Federico, L; Santucci, A

    1993-06-01

    Aim of this study was to evaluate the blood pressure (BP) measurement reliability of a light weight ambulatory BP and ECG recorder. Micro AM is a new 300 g portable apparatus that combines in one device both the ambulatory BP and solid state ECG recording. The dimensions of the Micro AM are 75 x 140 x 29 mm. The monitor measures BP using Korotkoff phase 1 for systolic and phase 5 for diastolic BP, and concurrently measures oscillometric BP, one method validating the other. In addition, the manual and programmed BP measurement modes can be supplemented by an "intelligent" mode in which the ECG triggers an ambulatory BP reading during an abnormal ST segment change. A standard mercury manometer was connected with the cuff of the Micro AM with a Y-shaped part, and 12 BP measurements were simultaneously taken at 5 min intervals by the automatic device in auscultatory mode and by a trained technician in 86 normotensive volunteers (aged from 18 to 44 years, 37 males and 49 females). The algebraic differences, the frequency distribution and the difference distribution of systolic and diastolic data between the 2 methods were calculated. The results show that the automatic method gives values for systolic BP that are lower than conventional ones (average differences -0.643 mmHg), whereas for diastolic BP, the values are higher (average differences +0.229 mmHg). Then, Student's paired t-test was used to evaluate statistically significant differences. The test relative to systolic BP was significant to the critical level of 0.1%, but the differences being 3 times smaller than the instrumental tolerance. On the contrary, diastolic BP differences were non significant. In conclusion, we found a good agreement between BP recorded automatically and by sphygmomanometer.

  15. 24 Hours to Save the NHS - The Chief Executive's Account of Reform 2000 to 2006 Crisp Nigel 24 Hours to Save the NHS - The Chief Executive's Account of Reform 2000 to 2006 248pp Oxford University Press 9780199639953 0199639957 [Formula: see text].

    PubMed

    2012-02-22

    The title of this book comes from Tony Blair's political slogan on the eve of the 1997 election when he told voters they had '24 hours to save the NHS' by voting for a Labour government. The new millennium, however, still found the NHS in decline.

  16. Development and validity of a 3-day smartphone assisted 24-hour recall to assess beverage consumption in a Chinese population: a randomized cross-over study.

    PubMed

    Smith, Lindsey P; Hua, Jenna; Seto, Edmund; Du, Shufa; Zang, Jiajie; Zou, Shurong; Popkin, Barry M; Mendez, Michelle A

    2014-01-01

    This paper addresses the need for diet assessment methods that capture the rapidly changing beverage consumption patterns in China. The objective of this study was to develop a 3-day smartphone-assisted 24-hour recall to improve the quantification of beverage intake amongst young Chinese adults (n=110) and validate, in a small subset (n=34), the extent to which the written record and smartphone-assisted recalls adequately estimated total fluid intake, using 24-hour urine samples. The smartphone-assisted method showed improved validity compared with the written record-assisted method, when comparing reported total fluid intake to total urine volume. However, participants reported consuming fewer beverages on the smartphone-assisted method compared with the written record-assisted method, primarily due to decreased consumption of traditional zero-energy beverages (i.e. water, tea) in the smartphone-assisted method. It is unclear why participants reported fewer beverages in the smartphone-assisted method than the written record -assisted method. One possibility is that participants found the smartphone method too cumbersome, and responded by decreasing beverage intake. These results suggest that smartphone-assisted 24-hour recalls perform comparably but do not appear to substantially improve beverage quantification compared with the current written record-based approach. In addition, we piloted a beverage screener to identify consumers of episodically consumed SSBs. As expected, a substantially higher proportion of consumers reported consuming SSBs on the beverage screener compared with either recall type, suggesting that a beverage screener may be useful in characterizing consumption of episodically consumed beverages in China's dynamic food and beverage landscape.

  17. Disproportional decrease in office blood pressure compared with 24-hour ambulatory blood pressure with antihypertensive treatment: dependency on pretreatment blood pressure levels.

    PubMed

    Schmieder, Roland E; Schmidt, Stephanie T; Riemer, Thomas; Dechend, Ralf; Hagedorn, Ina; Senges, Jochen; Messerli, Franz H; Zeymer, Uwe

    2014-11-01

    The long-term relationship between 24-hour ambulatory blood pressure (ABP) and office BP in patients on therapy is not well documented. From a registry we included all patients in whom antihypertensive therapy needed to be uptitrated. Drug treatment included the direct renin inhibitor aliskiren or an angiotensin-converting enzyme inhibitor/angiotensin receptor blocker or drugs not blocking the renin-angiotensin system, alone or on top of an existing drug regimen. In all patients, office BP and 24-hour ABP were obtained at baseline and after 1 year with validated devices. In the study population of 2722 patients, there was a good correlation between the change in office BP and 24-hour ABP (systolic: r=0.39; P<0.001; diastolic: r=0.34; P<0.001). However, the numeric decrease in office BP did not correspond to the decrease in ABP in a 1:1 fashion, for example, a decrease of 10, 20, and 30 mm Hg corresponded to a decrease of ≈7.2, 10.5, and 13.9 mm Hg in systolic ABP, respectively. The disproportionally greater decrease in systolic office BP compared with ABP was dependent on the level of the pretreatment BP, which was consistently higher for office BP than ABP. The white coat effect (difference between office BP and ABP) was on average 10/5 mm Hg lower 1 year after intensifying treatment and the magnitude of that was also dependent on pretreatment BP. There was a disproportionally greater decrease in systolic office BP than in ABP, which for both office BP and ABP seemed to depend on the pretreatment BP level.

  18. Ambulatory 24-hour cardiac oxygen consumption and blood pressure-heart rate variability: effects of nebivolol and valsartan alone and in combination.

    PubMed

    Izzo, Joseph L; Khan, Safi U; Saleem, Osman; Osmond, Peter J

    2015-07-01

    We compared an angiotensin receptor blocker (valsartan; VAL), a beta-blocker (nebivolol; NEB) and the combination of NEB/VAL with respect to 24-hour myocardial oxygen consumption (determined by 24-hour ambulatory heart rate-central systolic pressure product [ACRPP]) and its components. Subjects with hypertension (systolic blood pressure >140 or diastolic blood pressure >90; n = 26) were studied in a double-blinded, double-dummy, forced-titration, crossover design with 3 random-order experimental periods: VAL 320 mg, NEB 40 mg, and NEB/VAL 320/40 mg daily. After 4 weeks of each drug, ambulatory pulse wave analysis (MobilOGraph) was performed every 20 minutes for 24 hours. All three treatments resulted in nearly identical brachial and central systolic blood pressures. NEB alone or in combination with VAL resulted in lower ACRPP (by 11%-14%; P < .001 each) and heart rate (by 18%-20%; P < .001 each) compared with VAL, but stroke work (ACRPP per beat) was lower with VAL. Relative and adjusted variability (standard deviation and coefficient of variation) of heart rate were also lower with NEB and NEB/VAL than VAL. Results in African Americans, the majority subpopulation, were similar to those of the entire treatment group. We conclude that the rate-slowing effects of NEB cause ambulatory cardiac myocardial oxygen consumption to be lower with NEB monotherapy or NEB/VAL combination therapy than with VAL monotherapy. NEB/VAL is not superior to NEB alone in controlling heart rate, blood pressure, or ACRPP. Heart rate variability but not ACRPP variability is reduced by NEB or the combination NEB/VAL. There is no attenuation of beta-blocker-induced rate-slowing effects of in African Americans.

  19. Correlation of random urine protein creatinine (P-C) ratio with 24-hour urine protein and P-C ratio, based on physical activity: a pilot study.

    PubMed

    Sadjadi, Seyed-Ali; Jaipaul, Navin

    2010-09-07

    Quantification of proteinuria is usually predicated upon 24-hour urine collection. Multiple factors influence urine collection and the rate of protein and creatinine excretion. Urine collection is often incomplete, and therefore creatinine and protein excretion rates are underestimated. A random urine protein-creatinine (P-C) ratio has been shown over the years to be a reliable alternative to the 24-hour collection for detection and follow up of proteinuria. However, urine protein excretion may be influenced by physical activity. We studied 48 patients with proteinuria and varying levels of physical activity to determine the correlation between the measures of urine protein excretion. The correlation coefficient (r) between 24-hour urine total protein and random urine P-C ratio was 0.75 (P < 0.01) in the overall study population, but varied according to the level of proteinuria and physical activity in a stratified analysis: r = 0.99 (P < 0.001) and r = 0.95 (P < 0.01) in bedridden patients; r = 0.44 (P = not significant [NS]) and r = 0.54 (P = NS) in semiactive patients; and r = 0.44 (P = NS) and r = 0.58 (P < 0.05) in active patients with nephrotic- (>3500 mg/day) and non-nephrotic (<3500 mg/day) range proteinuria, respectively. The correlation appeared to be stronger between random urine and 24-hour urine P-C ratio for the overall study population (r = 0.84; P < 0.001), and when stratified according to the level of proteinuria and physical activity: r = 0.99 (P < 0.001) and r = 0.92 (P < 0.01) in bedridden patients; r = 0.61 (P = NS) and r = 0.54 (P = NS) in semiactive patients; and r = 0.64 (P < 0.02) and r = 0.52 (P < 0.05) in active patients with nephrotic and non-nephrotic range proteinuria, respectively. We conclude that the random urine P-C ratio is a reliable and practical way of estimating and following proteinuria, but its precision and accuracy may be affected by the level of patient physical activity.

  20. Variability of Urinary Concentrations of Polycyclic Aromatic Hydrocarbon Metabolite in General Population and Comparison of Spot, First-Morning, and 24-Hour Void Sampling

    PubMed Central

    Li, Zheng; Romanoff, Lovisa C.; Lewin, Michael D; Porter, Erin N; Trinidad, Debra A; Needham, Larry L; Patterson, Donald G; Sjödin, Andreas

    2015-01-01

    Urinary hydroxy polycyclic aromatic hydrocarbons (OH-PAHs) are commonly used in biomonitoring to assess exposure to polycyclic aromatic hydrocarbons (PAHs). Similar to other biologically non-persistent chemicals, OH-PAHs have relatively short biological half-lives (4.4–35 hours). Little information is available on their variability in urinary concentrations over time in non- occupationally exposed subjects. This study was designed to (i) study the variability of 9 urinary OH-PAH metabolite concentrations over time and (ii) calculate sample size requirements for future epidemiological studies based on spot urine, first morning void and 24-hour void sampling. Individual urine samples (n = 427) were collected during one week from 8 non-occupationally exposed adults. We recorded the time and volume of each urine excretion, dietary details, and the driving activities of the participants. Within subjects, the coefficients of variation (CV) for the wet-weight concentration of OH-PAHs in all samples ranged from 45% to 297%; creatinine adjustment reduced the CV to 19–288% (p < 0.001; paired t-test). The simulated 24-hour void concentrations were the least variable measure, with CVs ranging 13–182% for the 9 OH-PAHs. Within-day variability contributed on average 84%, and between-day variability accounted for 16% of the total variance of 1-hydroxypyrene (1-PYR). Intraclass correlation coefficients (ICC) of 1-PYR levels were 0.55 for spot urine samples, 0.60 for first-morning voids, and 0.76 for 24-hour voids, indicating a high degree of correlation between urine measurements collected from the same subject over time. Sample size calculations were performed to estimate the number of subjects needed for detecting differences in geometric mean at a statistical power of 80% for spot urine, first-morning, and 24-hour void sampling. These data will aid in the design of future studies of PAHs and possibly other biologically non-persistent chemicals and the interpretation of

  1. 40 CFR 125.87 - As an owner or operator of a new facility, must I perform monitoring?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (simple enumeration) for each species over a 24-hour period and no less than once per month when the... monitor entrainment rates (simple enumeration) for each species over a 24-hour period and no less...

  2. 40 CFR 125.87 - As an owner or operator of a new facility, must I perform monitoring?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (simple enumeration) for each species over a 24-hour period and no less than once per month when the... monitor entrainment rates (simple enumeration) for each species over a 24-hour period and no less...

  3. 40 CFR 125.87 - As an owner or operator of a new facility, must I perform monitoring?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (simple enumeration) for each species over a 24-hour period and no less than once per month when the... monitor entrainment rates (simple enumeration) for each species over a 24-hour period and no less...

  4. Treatment of burns in the first 24 hours: simple and practical guide by answering 10 questions in a step-by-step form

    PubMed Central

    2012-01-01

    Residents in training, medical students and other staff in surgical sector, emergency room (ER) and intensive care unit (ICU) or Burn Unit face a multitude of questions regarding burn care. Treatment of burns is not always straightforward. Furthermore, National and International guidelines differ from one region to another. On one hand, it is important to understand pathophysiology, classification of burns, surgical treatment, and the latest updates in burn science. On the other hand, the clinical situation for treating these cases needs clear guidelines to cover every single aspect during the treatment procedure. Thus, 10 questions have been organised and discussed in a step-by-step form in order to achieve the excellence of education and the optimal treatment of burn injuries in the first 24 hours. These 10 questions will clearly discuss referral criteria to the burn unit, primary and secondary survey, estimation of the total burned surface area (%TBSA) and the degree of burns as well as resuscitation process, routine interventions, laboratory tests, indications of Bronchoscopy and special considerations for Inhalation trauma, immediate consultations and referrals, emergency surgery and admission orders. Understanding and answering the 10 questions will not only cover the management process of Burns during the first 24 hours but also seems to be an interactive clear guide for education purpose. PMID:22583548

  5. Sodium and potassium intake in South Africa: an evaluation of 24-hour urine collections in a white, black, and Indian population.

    PubMed

    Swanepoel, Bianca; Schutte, Aletta E; Cockeran, Marike; Steyn, Krisela; Wentzel-Viljoen, Edelweiss

    2016-11-01

    Limited number of studies on salt intake has been conducted in the South Africa. The present study established the sodium and potassium excretion (24-hour urine collection) of three different South African populations. In total, 692 successful 24-hour urine collections were analyzed for sodium, potassium, and iodine levels. The median sodium and potassium excretion was 122.9 and 33.5 mmol/d, respectively, and the median salt intake was 7.2 g/d. The majority (92.8%) of the population did not meet the recommended potassium intake/d, and 65.6% consumed more than 6 g of salt/d. Potassium excretion showed a linear relationship with salt intake (P-trend ≤ .001). The median sodium-to-potassium ratio was 3.5. These findings support the South African government's sodium reduction legislation, as well as global initiatives. More consideration should be given to promoting the intake of potassium-rich foods, as this may have a greater public health impact than focusing only on dietary sodium reduction.

  6. Treatment of burns in the first 24 hours: simple and practical guide by answering 10 questions in a step-by-step form.

    PubMed

    Alharbi, Ziyad; Piatkowski, Andrzej; Dembinski, Rolf; Reckort, Sven; Grieb, Gerrit; Kauczok, Jens; Pallua, Norbert

    2012-05-14

    Residents in training, medical students and other staff in surgical sector, emergency room (ER) and intensive care unit (ICU) or Burn Unit face a multitude of questions regarding burn care. Treatment of burns is not always straightforward. Furthermore, National and International guidelines differ from one region to another. On one hand, it is important to understand pathophysiology, classification of burns, surgical treatment, and the latest updates in burn science. On the other hand, the clinical situation for treating these cases needs clear guidelines to cover every single aspect during the treatment procedure. Thus, 10 questions have been organised and discussed in a step-by-step form in order to achieve the excellence of education and the optimal treatment of burn injuries in the first 24 hours. These 10 questions will clearly discuss referral criteria to the burn unit, primary and secondary survey, estimation of the total burned surface area (%TBSA) and the degree of burns as well as resuscitation process, routine interventions, laboratory tests, indications of Bronchoscopy and special considerations for Inhalation trauma, immediate consultations and referrals, emergency surgery and admission orders. Understanding and answering the 10 questions will not only cover the management process of Burns during the first 24 hours but also seems to be an interactive clear guide for education purpose.

  7. Comparison between two standardized cultural methods and 24 hour duplex SYBR green real-time PCR assay for Salmonella detectionin meat samples.

    PubMed

    Delibato, Elisabetta; Fiore, Alfonsina; Anniballi, Fabrizio; Auricchio, Bruna; Filetici, Emma; Orefice, Leucio; Losio, Marina Nadia; De Medici, Dario

    2011-07-01

    Food-borne diseases caused by Salmonella represent a worldwide public health problem. Salmonella must be absent in an established amount depending on the kind of the product and usually cultural methods have to be applied to evaluate the compliance of the products. ISO 6579:2002 in Europe and FSIS MLG 4.04.:2008 in the USA have usually been employed to detect Salmonella in meat, poultry and egg products. A Real Time PCR method using probes has recently been validated against the NMKL (Nordic Committee on Food Analysis) standard method. This method has been modified using the less expensive Sybr Green Real Time PCR approach and applied directly in the 18 hours preenrichment broth for the purpose of detecting Salmonella in meat products in less than 24 hours. The purpose of this study was to: - compare the effectiveness of ISO and FSIS cultural methods; - develop a new 24 hour duplex Sybr Green Real Time PCR-melting curve analysis; - evaluate the performance of Salmonella, Standard Method, Rapid Method, SYBR Green Real Time PCR. The equivalence between ISO and FSIS methods was demonstrated and the use of SYBR Green Real Time PCR as a screening tool for negative results seems appealing especially to evaluate compliance with the HACCP systems.

  8. A Case Report on Dyskinesia Following Rivastigmine Patch 13.3 mg/24 hours for Alzheimer's Disease: Perspective in the Movement Disorders Spectrum Following Use of Cholinesterase Inhibitors.

    PubMed

    Diaz, Maria Cristina B; Rosales, Raymond L

    2015-08-01

    Current reports on movement disorder adverse effects of acetylcholinesterase inhibitors only include extrapyramidal symptoms and myoclonus.Here is a case of an 81-year-old female Filipino with dementia who presented with first-onset generalized choreiform movements.The etiology of the clinical finding of dyskinesia was investigated through laboratories, neuroimaging, and electroencephalogram, all of which yielded negative results. Review of her medications included the rivastigmine (Exelon) patch, which had just been increased to 13.3 mg/24-hour-dose 3 months prior. With all other possible causes excluded, a trial discontinuation of rivastigmine, showed decreased frequency of the dyskinesia 48 hours after, with complete resolution after 6 days, and no recurrence since then.This case thus presents a probable association or causality between the choreiform movement and rivastigmine at 13.3 mg/24-hour-dose patch because of clear temporal proximity, lack of alternative explanations, and a reversal of the dyskinesia upon medicament discontinuation.

  9. Effect of current and lifetime posttraumatic stress disorder on 24-hour urinary catecholamines and cortisol: results from the Mind Your Heart Study

    PubMed Central

    Wingenfeld, Katja; Whooley, Mary A.; Neylan, Thomas C.; Otte, Christian; Cohen, Beth E.

    2014-01-01

    Summary Posttraumatic stress disorder (PTSD) is associated with an increased risk of cardiovascular disease and several other chronic illnesses. Alterations in the sympathetic nervous system (SNS) and the hypothalamic-pituitary-adrenal (HPA) axis in PTSD might contribute to these associations but findings regarding SNS and HPA activity in PTSD are heterogeneous. We measured 24-hour urinary catecholamines and cortisol in a large cohort of adult outpatients recruited from 2 Veterans Affairs medical centers. 24-hour urinary norepinephrine, epinephrine, dopamine and cortisol were measured by tandem mass spectrometry. Lifetime and current PTSD were assessed with the Clinician Administered PTSD Scale using DSM-IV-TR criteria. Out of 613 participants, 199 (32.5%) had current PTSD, 100 (16.3%) had lifetime but not current PTSD, and 314 (51.2%) never had PTSD. Patients with current PTSD had significantly higher norepinephrine secretion compared to those without PTSD. Patients in the lifetime PTSD group exhibited lower cortisol values compared to those without PTSD. Participants who never had PTSD showed the lowest norepinephrine and the highest cortisol values. All results remained stable when controlling for potentially confounding variables. This study provides evidence for increased norepinephrine secretion and decreased cortisol in PTSD. Future longitudinal studies are needed to determine whether these changes contribute to adverse health outcomes in patients with PTSD. PMID:25459895

  10. 24-hour urine copper test

    MedlinePlus

    ... associated with providing a urine sample. Alternative Names Quantitative urinary copper Images Copper urine test References McPherson ... for the diagnosis or treatment of any medical condition. A licensed physician should be consulted for diagnosis ...

  11. Antiplatelet Effect Durability of a Novel, 24-Hour, Extended-Release Prescription Formulation of Acetylsalicylic Acid in Patients With Type 2 Diabetes Mellitus.

    PubMed

    Gurbel, Paul A; Bliden, Kevin P; Chaudhary, Rahul; Patrick, Jeff; Liu, Fang; Chen, Gailing; McLeod, Christopher; Tantry, Udaya S

    2016-12-15

    High platelet reactivity and high platelet turnover have been implicated in incomplete platelet inhibition during immediate-release acetylsalicylic acid therapy in patients with type 2 diabetes mellitus (DM). An extended-release acetylsalicylic acid (ER-ASA; Durlaza) formulation was developed to provide 24-hour antithrombotic effects with once-daily dosing. The objective of the study was to evaluate the antiplatelet effects of ER-ASA in patients with DM. In this open-label, single-center study, patients with DM (n = 40) and multiple cardiovascular risk factors received ER-ASA 162.5 mg/day for 14 ± 4 days. Multiple platelet function tests, serum and urinary thromboxane B2 metabolites, prostacyclin metabolite, and high-sensitive C-reactive protein levels were assessed at 1, 12, 16, and 24 hours post-dose. Patients with high platelet turnover and/or high platelet reactivity were treated with ER-ASA 325 mg/day for 14 ± 4 days, and laboratory analyses were repeated. All patients responded to ER-ASA 162.5 mg/day as measured by arachidonic acid-induced aggregation, and there was no loss of the platelet inhibitory effect of ER-ASA 162.5 mg/day over 24 hours post-dose (p = not significant). The antiplatelet effect was sustained over 24 hours for all platelet function measurements. Mean 1- to 24-hour serum thromboxane B2 levels were low with both doses and were lower with ER-ASA 325 mg/day compared with 162.5 mg/day therapy (p = 0.002). In conclusion, ER-ASA 162.5 mg daily dose provided sustained antiplatelet effects over 24 hours in patients with type 2 DM and multiple cardiovascular risk factors and had a favorable tolerability profile.

  12. Validity of a multipass, web-based, 24-hour self-administered recall for assessment of total energy intake in blacks and whites.

    PubMed

    Arab, Lenore; Tseng, Chi-Hong; Ang, Alfonso; Jardack, Patricia

    2011-12-01

    To date, Web-based 24-hour recalls have not been validated using objective biomarkers. From 2006 to 2009, the validity of 6 Web-based DietDay 24-hour recalls was tested among 115 black and 118 white healthy adults from Los Angeles, California, by using the doubly labeled water method, and the results were compared with the results of the Diet History Questionnaire, a food frequency questionnaire developed by the National Cancer Institute. The authors performed repeated measurements in a subset of 53 subjects approximately 6 months later to estimate the stability of the doubly labeled water measurement. The attenuation factors for the DietDay recall were 0.30 for blacks and 0.26 for whites. For the Diet History Questionnaire, the attenuation factors were 0.15 and 0.17 for blacks and whites, respectively. Adjusted correlations between true energy intake and the recalls were 0.50 and 0.47 for blacks and whites, respectively, for the DietDay recall. For the Diet History Questionnaire, they were 0.34 and 0.36 for blacks and whites, respectively. The rate of underreporting of more than 30% of calories was lower with the recalls than with the questionnaire (25% and 41% vs. 34% and 52% for blacks and whites, respectively). These findings suggest that Web-based DietDay dietary recalls offer an inexpensive and widely accessible dietary assessment alternative, the validity of which is equally strong among black and white adults. The validity of the Web-administered recall was superior to that of the paper food frequency questionnaire.

  13. Acute effects of nasal continuous positive airway pressure on 24-hour blood pressure and catecholamines in patients with obstructive sleep apnea.

    PubMed

    Minemura, H; Akashiba, T; Yamamoto, H; Akahoshi, T; Kosaka, N; Horie, T

    1998-12-01

    To assess the acute effects of nasal continuous positive airway pressure (CPAP) on the 24-hour blood pressure and the secretion of catecholamines in urine and plasma, we investigated the changes in the 24-hour blood pressure and urinary and plasma concentrations of epinephrine (E) and norepinephrine (NE) in 26 men with obstructive sleep apnea (OSA) with and without nasal CPAP. Nasal CPAP resulted in significant decreases in the daytime diastolic pressure (from 86 +/-16 mmHg to 83+/-12 mmHg), the nighttime diastolic pressure (from 81+/-12 mmHg to 77+/-9 mmHg) and the nighttime systolic pressures (from 125+/-15 mmHg to 120+/-10 mmHg). There was no significant difference between patients with and without CPAP in the daytime or nighttime urinary E level, but patients who received CPAP showed a significant decrease in daytime urinary NE level (from 156+/-112 microg/14h to 119+/-101 microg/14h) and nighttime urinary NE level (from 143+/-91 microg/10h to 112+/-65 microg/10h). The morning plasma level of NE also decreased (from 371+/-181 pg/ml to 273 +/-148 pg/ml) in patients who received nasal CPAP (p<0.02), but the plasma level of E remained unchanged. There were no correlations between PSG parameters and the reductions in blood pressure and the catecholamine levels induced by nasal CPAP. These findings suggest that OSA contributes, at least in part, to the development of systemic hypertension by increasing sympathetic nervous activity.

  14. Correlation of Occupational Stress Index with 24-hour Urine Cortisol and Serum DHEA Sulfate among City Bus Drivers: A Cross-sectional Study

    PubMed Central

    Lin, Mia Chihya; Lu, Luo; Tai, John Jen

    2011-01-01

    Objectives The questionnaire of occupational stress index (OSI) has been popular in the workplace, and it has been tailored for bus drivers in Taiwan. Nevertheless, its outcomes for participants are based on self-evaluations, thus validation by their physiological stress biomarker is warranted and this is the main goal of this study. Methods A cross-sectional study of sixty-three city bus drivers and fifty-four supporting staffs for comparison was conducted. Questionnaire surveys, 24-hour urine cortisol testing, and blood draws for dehydroepiandrosterone-sulfate (DHEA-S) testing were performed. The measured concentrations of these biological measures were logarithmically transformed before the statistical analysis where various scores of stressor factors, moderators, and stress effects of each OSI domain were analyzed by applying multiple linear regression models. Results For drivers, the elevated 24-hour urine cortisol level was associated with a worker's relationship with their supervisor and any life change events in the most recent 3 months. The DHEA-S level was higher in drivers of younger age as well as drivers with more concerns relating to their salary and bonuses. Non-drivers showed no association between any stressor or satisfaction and urine cortisol and blood DHEA-S levels. Conclusion Measurements of biomarkers may offer additional stress evaluations with OSI questionnaires for bus drivers. Increased DHEA-S and cortisol levels may result from stressors like income security. Prevention efforts towards occupational stress and life events and health promotional efforts for aged driver were important anti-stress remedies. PMID:22953199

  15. A Pre-Screening Questionnaire to Predict Non-24-Hour Sleep-Wake Rhythm Disorder (N24HSWD) among the Blind

    PubMed Central

    Flynn-Evans, Erin E.; Lockley, Steven W.

    2016-01-01

    Study Objectives: There is currently no questionnaire-based pre-screening tool available to detect non-24-hour sleep-wake rhythm disorder (N24HSWD) among blind patients. Our goal was to develop such a tool, derived from gold standard, objective hormonal measures of circadian entrainment status, for the detection of N24HSWD among those with visual impairment. Methods: We evaluated the contribution of 40 variables in their ability to predict N24HSWD among 127 blind women, classified using urinary 6-sulfatoxymelatonin period, an objective marker of circadian entrainment status in this population. We subjected the 40 candidate predictors to 1,000 bootstrapped iterations of a logistic regression forward selection model to predict N24HSWD, with model inclusion set at the p < 0.05 level. We removed any predictors that were not selected at least 1% of the time in the 1,000 bootstrapped models and applied a second round of 1,000 bootstrapped logistic regression forward selection models to the remaining 23 candidate predictors. We included all questions that were selected at least 10% of the time in the final model. We subjected the selected predictors to a final logistic regression model to predict N24SWD over 1,000 bootstrapped models to calculate the concordance statistic and adjusted optimism of the final model. We used this information to generate a predictive model and determined the sensitivity and specificity of the model. Finally, we applied the model to a cohort of 1,262 blind women who completed the survey, but did not collect urine samples. Results: The final model consisted of eight questions. The concordance statistic, adjusted for bootstrapping, was 0.85. The positive predictive value was 88%, the negative predictive value was 79%. Applying this model to our larger dataset of women, we found that 61% of those without light perception, and 27% with some degree of light perception, would be referred for further screening for N24HSWD. Conclusions: Our model has

  16. Metabolic Engineering of Light and Dark Biochemical Pathways in Wild-Type and Mutant Strains of Synechocystis PCC 6803 for Maximal, 24-Hour Production of Hydrogen Gas

    SciTech Connect

    Ely, Roger L.; Chaplen, Frank W.R.

    2014-03-11

    This project used the cyanobacterial species Synechocystis PCC 6803 to pursue two lines of inquiry, with each line addressing one of the two main factors affecting hydrogen (H2) production in Synechocystis PCC 6803: NADPH availability and O2 sensitivity. H2 production in Synechocystis PCC 6803 requires a very high NADPH:NADP+ ratio, that is, the NADP pool must be highly reduced, which can be problematic because several metabolic pathways potentially can act to raise or lower NADPH levels. Also, though the [NiFe]-hydrogenase in PCC 6803 is constitutively expressed, it is reversibly inactivated at very low O2 concentrations. Largely because of this O2 sensitivity and the requirement for high NADPH levels, a major portion of overall H2 production occurs under anoxic conditions in the dark, supported by breakdown of glycogen or other organic substrates accumulated during photosynthesis. Also, other factors, such as N or S limitation, pH changes, presence of other substances, or deletion of particular respiratory components, can affect light or dark H2 production. Therefore, in the first line of inquiry, under a number of culture conditions with wild type (WT) Synechocystis PCC 6803 cells and a mutant with impaired type I NADPH-dehydrogenase (NDH-1) function, we used H2 production profiling and metabolic flux analysis, with and without specific inhibitors, to examine systematically the pathways involved in light and dark H2 production. Results from this work provided rational bases for metabolic engineering to maximize photobiological H2 production on a 24-hour basis. In the second line of inquiry, we used site-directed mutagenesis to create mutants with hydrogenase enzymes exhibiting greater O2 tolerance. The research addressed the following four tasks: 1. Evaluate the effects of various culture conditions (N, S, or P limitation; light/dark; pH; exogenous organic carbon) on H2 production profiles of WT cells and an NDH-1 mutant; 2. Conduct metabolic flux analyses for

  17. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs

    PubMed Central

    Hodkinson, Emily C.; Neijts, Melanie; Sadrieh, Arash; Imtiaz, Mohammad S.; Baumert, Mathias; Subbiah, Rajesh N.; Hayward, Christopher S.; Boomsma, Dorret; Willemsen, Gonneke; Vandenberg, Jamie I.; Hill, Adam P.; De Geus, Eco

    2016-01-01

    Introduction: The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. Methods and Results: Holter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modeling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters. Conclusions: Here we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic—environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease. PMID:27199769

  18. EXTRAPOLATION TECHNIQUES EVALUATING 24 HOURS OF AVERAGE ELECTROMAGNETIC FIELD EMITTED BY RADIO BASE STATION INSTALLATIONS: SPECTRUM ANALYZER MEASUREMENTS OF LTE AND UMTS SIGNALS.

    PubMed

    Mossetti, Stefano; de Bartolo, Daniela; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina; Nava, Elisa

    2016-12-01

    International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures.

  19. Control of bleeding by silk ligation and diathermy coagulation during tonsillectomy: A comparison of efficacy of the two techniques in the first 24 hours after surgery

    PubMed Central

    Anwar, Khurshid; Ahmad, Rafiq; Khan, Muneeb

    2015-01-01

    Objective: To assess and compare the relative efficacy of silk ligation and diathermy coagulation techniques in controlling bleeding during tonsillectomy in the first 24 hours. Methods: This prospective study was conducted at the Department of ENT, Khalifa Gul Nawaz Teaching Hospital, Bannu and this department related consultants’ private clinics from January 1, 2012 to December 31, 2014. The study included 180 cases. All patients included were having history of recurrent, acute tonsillitis, with more than 6–7 episodes in one year, five episodes per year for two years, or three episodes per year for three years. All the surgeries were performed by dissection method. Haemostasis during the procedure was secured by either ligation with silk 1 or using diathermy. The results were analyzed using SPSS 16.0 for windows. Results: A total of180 cases were included in the study. The ages of the patients ranged from 5 to 40 years with the mean age of 15.56 years and a std.deviation of +/- 8.24. The male to female ratio was 1.25:1. The number of hemorrhages occurring was greater in the ‘diathermy coagulation’ group as compared to the ‘silk ligation’ group. However, the observed difference was statistically insignificant (p >.05). Conclusion: Primary haemorrhage occurring during tonsillectomy is a serious threat and control of bleeding during the procedure should therefore be meticulous. Both suture ligation and coagulation diathermy for control of bleeders during the procedure by dissection method are equally effective. PMID:26430438

  20. Computer simulation of the effect of dDAVP with saline loading on fluid balance after 24-hour head-down tilt

    NASA Technical Reports Server (NTRS)

    Srinivasan, R. S.; Simanonok, K. E.; Charles, J. B.

    1994-01-01

    Fluid loading (FL) before Shuttle reentry is a countermeasure currently in use by NASA to improve the orthostatic tolerance of astronauts during reentry and postflight. The fluid load consists of water and salt tablets equivalent to 32 oz (946 ml) of isotonic saline. However, the effectiveness of this countermeasure has been observed to decrease with the duration of spaceflight. The countermeasure's effectiveness may be improved by enhancing fluid retention using analogs of vasopressin such as lypressin (LVP) and desmopressin (dDAVP). In a computer simulation study reported previously, we attempted to assess the improvement in fluid retention obtained by the use of LVP administered before FL. The present study is concerned with the use of dDAVP. In a recent 24-hour, 6 degree head-down tilt (HDT) study involving seven men, dDAVP was found to improve orthostatic tolerance as assessed by both lower body negative pressure (LBNP) and stand tests. The treatment restored Luft's cumulative stress index (cumulative product of magnitude and duration of LBNP) to nearly pre-bedrest level. The heart rate was lower and stroke volume was marginally higher at the same LBNP levels with administration of dDAVP compared to placebo. Lower heart rates were also observed with dDAVP during stand test, despite the lower level of cardiovascular stress. These improvements were seen with only a small but significant increase in plasma volume of approximately 3 percent. This paper presents a computer simulation analysis of some of the results of this HDT study.

  1. Canadian 24-Hour Movement Guidelines for Children and Youth: Exploring the perceptions of stakeholders regarding their acceptability, barriers to uptake, and dissemination.

    PubMed

    Faulkner, Guy; White, Lauren; Riazi, Negin; Latimer-Cheung, Amy E; Tremblay, Mark S

    2016-06-01

    Engaging stakeholders in the development of guidelines and plans for implementation is vital. The purpose of this study was to examine stakeholders' (parents, teachers, exercise professionals, paediatricians, and youth) perceptions of the Canadian 24-Hour Movement Behaviour Guidelines for Children and Youth ("Movement Guidelines"). Stakeholders (n = 104) engaged in semi-structured focus groups or interviews to discuss the perceived acceptability of the guidelines, potential barriers to implementation, and preferred methods and messengers of dissemination. A thematic analysis was conducted. Overall, there was consistent support across all stakeholder groups, with the exception of youth participants, for the Movement Guidelines. Stakeholders identified a range of barriers to the uptake of the guidelines including concerns with accurately defining key terms such as "recreational" screen time; everyday challenges such as financial and time constraints; and the possibility of the Movement Guidelines becoming just another source of stress and guilt for already busy and overwhelmed parents. Participants identified a range of recommended methods and messengers for future dissemination. School and medical settings were the most commonly recommended settings through which dissemination efforts should be delivered. Overall, participants representing a range of stakeholder groups were receptive to the new Movement Guidelines and endorsed their value. In complementing the Movement Guidelines, messaging and resources will need to be developed that address common concerns participants had regarding their dissemination and implementation.

  2. Donor-reactive CD8 Memory T Cells Infiltrate Cardiac Allografts Within 24 Hours Post-Transplant in Naïve Recipients

    PubMed Central

    Schenk, A.D.; Nozaki, T.; Rabant, M.; Valujskikh, A.; Fairchild, R.L.

    2008-01-01

    Normal immune responses stimulated by pathogenic and environmental antigens generate memory T cells that react with donor antigens and no currently used immunosuppressive drug completely inhibits memory T cell function. While donor-reactive memory T cells clearly compromise graft outcomes, mechanisms utilized by memory T cells to promote rejection are largely unknown. In the current study we investigated how early endogenous memory cells infiltrate and express effector function in cardiac allografts. Endogenous CD8 memory T cells in non-sensitized recipients distinguish syngeneic vs. allogeneic cardiac allografts within 24 hours of reperfusion. CD8-dependent production of IFN-γ and CXCL9/Mig was observed 24–72 hours post-transplant in allografts but not isografts. CXCL9 was produced by donor cells in response to IFN-γ made by recipient CD8 T cells reactive to donor class I MHC molecules. Activated CD8 T cells were detected in allografts at least three days before donor-specific effector T cells producing IFN-γ were detected in the recipient spleen. Early inflammation mediated by donor-reactive CD8 memory T cells greatly enhanced primed effector T cell infiltration into allografts. These results suggest that strategies for optimal inhibition of alloimmunity should include neutralization of infiltrating CD8 memory T cells within a very narrow window after transplantation. PMID:18557725

  3. Influence of irrigation protocols on the bond strength of fiber posts cemented with a self-adhesive luting agent 24 hours after endodontic treatment.

    PubMed

    Lima, Jessica Ferraz Carvalho; Lima, Adriano Fonseca; Humel, Maria Malerba Colombi; Paulillo, Luis Alexandre Maffei Sartini; Marchi, Giselle Maria; Ferraz, Caio Cezar Randi

    2015-01-01

    The aim of this in vitro study was to evaluate the influence of different irrigation protocols on the bond strength, at different root depths, of fiber posts cemented with a self-adhesive cement 24 hours after endodontic treatment. Fifty-six bovine incisor roots were endodontically prepared and separated into 7 groups (n = 8) according to irrigation protocols: group 1, sterile saline (control); group 2, chlorhexidine (CHX) gel 2% and saline; group 3, sodium hypochlorite (NaOCl) 5.25% and saline; group 4, CHX and saline (final irrigation with ethylenediaminetetraacetic acid [EDTA] 17%); group 5, NaOCl and saline (final irrigation with EDTA); group 6, CHX and saline (final irrigation with NaOCl and EDTA); and group 7, NaOCl (final irrigation with CHX and EDTA). No statistically significant difference was found among the groups. Within the limitations of this study, it can be concluded that the different irrigation protocols did not influence the bond strength of self-adhesive resin cement, which presented similar behaviors at the 3 root depths studied.

  4. The Telemetric and Holter ECG Warehouse (THEW): the first three years of development and research.

    PubMed

    Couderc, Jean-Philippe

    2012-01-01

    The Telemetric and Holter ECG Warehouse (THEW) hosts more than 3700 digital 24-Holter ECG recordings from 13 independent studies. In addition to the ECGs, the repository includes patient information in separate clinical database with content varying according to the study focus. In its third year of activities, the THEW database has been accessed by researchers from 37 universities and 16 corporations located in 16 countries worldwide. Twenty publications were released primarily focusing on the development and validation of ECG-based technologies. This communication describes the content of the databases of the repository with brief summary of the research and development projects completed using these data.

  5. 2001: A Space Odyssey Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley; Dudzinski, Leonard A.

    2003-01-01

    The prospects for 24 hour commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, high leverage technologies: liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and lunar-derived oxygen (LUNOX) production. Iron-rich volcanic glass, or orange soil, discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4 percent oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an afterburner into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat, essentially scramjet propulsion in reverse. By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that big engine performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or in-line Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an expendable mode initially, to maximize delivered surface payload on each mission. The increased payload is

  6. "2001: A Space Odyssey" Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    2001-01-01

    The prospects for "24 hour" commuter flights to the Moon. similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale. are examined using two near term. "high leverage" technologies-liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Iron-rich volcanic glass. or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow. has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat-essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller. more affordable. easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  7. "2001: A Space Odyssey" Revisited--The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    1998-01-01

    The prospects for "24 hour" commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, "high leverage" technologies--liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Ironrich volcanic glass, or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way, LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging front the engine's choked sonic throat--essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  8. Epidemiology of Urban Traffic Accident Victims Hospitalized More Than 24 Hours in a Level III Trauma Center, Kashan County, Iran, During 2012-2013

    PubMed Central

    Mahdian, Mehrdad; Sehat, Mojtaba; Fazel, Mohammad Reza; Moraveji, Alireza; Mohammadzadeh, Mahdi

    2015-01-01

    Background: Urban traffic accidents are an extensively significant problem in small and busy towns in Iran. This study tried to explore the epidemiological pattern of urban traffic accidents in Kashan and Aran-Bidgol cities, Iran. Objectives: This study aimed to assess various epidemiological factors affecting victims of trauma admitted to a main trauma center in Iran. Patients and Methods: During a retrospective study, data including age, sex, injury type and pattern, outcome, hospital stay and treatment expenditures regarding urban Road Traffic Accidents (RTAs) for one year (March 2012-March 2013) were obtained from the registry of trauma research center, emergency medical services and deputy of health of Kashan University of Medical Sciences. One-way ANOVA and chi-square tests were used to analyze data using SPSS version 16.0. P value < 0.05 was considered significant. Results: A total of 1723 victims (82.6% male, sex ratio of almost 5:1) were considered in this study. Mortality rate in trauma cases hospitalized more than 24 hours during our study was 0.8%. Young motorcyclist men with the rate of more than 103 per 10000 were the most vulnerable group. The most common injury was head injury (73.6%) followed by lower limb injury (33.2%). A significant association was found between mechanism of injury and head, lower limb, multiple injuries and high risk age group. Conclusions: Urban RTAs are one of the most important problems in Kashan and Aran-Bidgol cities, which impose a great economic burden on health system. Motorcyclists are the most vulnerable victims and multiple trauma and head injury are seen among them extensively. PMID:26101765

  9. Spatial characteristics of extreme rainfall over China with hourly through 24-hour accumulation periods based on national-level hourly rain gauge data

    NASA Astrophysics Data System (ADS)

    Zheng, Yongguang; Xue, Ming; Li, Bo; Chen, Jiong; Tao, Zuyu

    2016-11-01

    Hourly rainfall measurements of 1919 national-level meteorological stations from 1981 through 2012 are used to document, for the first time, the climatology of extreme rainfall in hourly through 24-h accumulation periods in China. Rainfall amounts for 3-, 6-, 12- and 24-h periods at each station are constructed through running accumulation from hourly rainfall data that have been screened by proper quality control procedures. For each station and for each accumulation period, the historical maximum is found, and the corresponding 50-year return values are estimated using generalized extreme value theory. Based on the percentiles of the two types of extreme rainfall values among all the stations, standard thresholds separating Grade I, Grade II and Grade III extreme rainfall are established, which roughly correspond to the 70th and 90th percentiles for each of the accumulation periods. The spatial characteristics of the two types of extreme rainfall are then examined for different accumulation periods. The spatial distributions of extreme rainfall in hourly through 6-h periods are more similar than those of 12- and 24-h periods. Grade III rainfall is mostly found over South China, the western Sichuan Basin, along the southern and eastern coastlines, and in the large river basins and plains. There are similar numbers of stations with Grade III extreme hourly rainfall north and south of 30°N, but the percentage increases to about 70% south of 30°N as the accumulation period increases to 24 hours, reflecting richer moisture and more prolonged rain events in southern China. Potential applications of the extreme rainfall climatology and classification standards are suggested at the end.

  10. Establishing normal plasma and 24-hour urinary biochemistry ranges in C3H, BALB/c and C57BL/6J mice following acclimatization in metabolic cages.

    PubMed

    Stechman, Michael J; Ahmad, Bushra N; Loh, Nellie Y; Reed, Anita A C; Stewart, Michelle; Wells, Sara; Hough, Tertius; Bentley, Liz; Cox, Roger D; Brown, Steve D M; Thakker, Rajesh V

    2010-07-01

    Physiological studies of mice are facilitated by normal plasma and 24-hour urinary reference ranges, but variability of these parameters may increase due to stress that is induced by housing in metabolic cages. We assessed daily weight, food and water intake, urine volume and final day measurements of the following: plasma sodium, potassium, chloride, urea, creatinine, calcium, phosphate, alkaline phosphatase, albumin, cholesterol and glucose; and urinary sodium, potassium, calcium, phosphate, glucose and protein in 24- to 30-week-old C3H/HeH, BALB/cAnNCrl and C57BL/6J mice. Between 15 and 20 mice of each sex from all three strains were individually housed in metabolic cages with ad libitum feeding for up to seven days. Acclimatization was evaluated using general linear modelling for repeated measures and comparison of biochemical data was by unpaired t-test and analysis of variance (SPSS version 12.0.1). Following an initial 5-10% fall in body weight, daily dietary intake, urinary output and weight in all three strains reached stable values after 3-4 days of confinement. Significant differences in plasma glucose, cholesterol, urea, chloride, calcium and albumin, and urinary glucose, sodium, phosphate, calcium and protein were observed between strains and genders. Thus, these results provide normal reference values for plasma and urinary biochemistry in three strains housed in metabolic cages and demonstrate that 3-4 days are required to reach equilibrium in metabolic cage studies. These variations due to strain and gender have significant implications for selecting the appropriate strain upon which to breed genetically-altered models of metabolic and renal disease.

  11. External Beam Radiotherapy Plus 24-Hour Continuous Infusion of Gemcitabine in Unresectable Pancreatic Carcinoma: Long-Term Results of a Phase II Study

    SciTech Connect

    Mattiucci, Gian C.; Morganti, Alessio G.; Valentini, Vincenzo; Ippolito, Edy; Alfieri, Sergio; Antinori, Armando; Crucitti, Antonio; D'Agostino, Giuseppe R.; Di Lullo, Liberato; Luzi, Stefano; Mantini, Giovanna; Smaniotto, Daniela; Doglietto, Gian B.; Cellini, Numa

    2010-03-01

    Purpose: To evaluate the efficacy of gemcitabine-based chemoradiation (CT-RT) in treating patients (pts) affected by locally advanced pancreatic cancers (LAPC). Methods and Materials: Weekly gemcitabine (100 mg/m{sup 2}) was given as a 24-hour infusion during the course of three-dimensional radiotherapy (50.4 Gy to the tumor, 39.6 Gy to the nodes). After CT-RT, pts received five cycles of sequential chemotherapy with gemcitabine (1000 mg/m{sup 2}; 1, 8, q21). Response rate was assessed according to World Health Organization criteria 6 weeks after the end of CT-RT. Local control (LC), time to progression (TTP), metastases-free survival (MFS), and overall survival (OS) were analyzed by the Kaplan Meier method. Results: Forty pts (male/female 22/18; median age 62 years, range, 36-76) were treated from 2000 to 2005. The majority had T4 tumour (n = 34, 85%), six pts (15%) had T3 tumour. Sixteen pts (40%) were node positive at diagnosis. Grade 3-4 acute toxicity was observed in 21 pts (52.5%). Thirty pts (75%) completed the treatment schedule. A clinical response was achieved in 12 pts (30%). With a median follow-up of 76 months (range, 32-98), 2-year LC was 39.6% (median, 12 months), 2-year TTP was 18.4% (median, 10 months), and 2-year MFS was 29.7% (median, 10 months). Two-year OS (25%; median, 15.5 months) compared with our previous study on 5-fluorouracil-based CT-RT (2.8%) was significantly improved (p <0.001). Conclusions: Gemcitabine CT-RT seems correlated with improved outcomes. Healthier patients who are likely to complete the treatment schedule may benefit most from this therapy.

  12. Acute and chronic effects of a hypocaloric diet on 24-hour blood pressure, heart rate and heart-rate variability in mildly-to-moderately obese patients with essential hypertension.

    PubMed

    Minami, J; Kawano, Y; Ishimitsu, T; Matsuoka, H; Takishita, S

    1999-11-01

    We examined the acute and chronic effects of a nutritionally balanced, moderately hypocaloric diet on 24-hour ambulatory blood pressure, heart rate and heart-rate variability in mildly-to-moderately obese patients with essential hypertension. We enrolled 16 obese patients with essential hypertension [age: 51-76 years, body mass index (BMI): 26-32 kg/m2]. For the initial week, a standard diet of 2,000 kcal/day was given, followed by a 3-week of a hypocaloric diet of 850 kcal/day. In the last period of the standard diet and in the first and the last periods of the hypocaloric diet, each subject's 24-hour ambulatory blood pressure, heart rate and R-R intervals of the electrocardiogram were recorded, and electrolytes and catecholamines in 24-hour urine samples were also measured. A power spectral analysis of the heart-rate variability was performed over a 24-hour period based on the autoregressive method. The subjects lost 3.7+/-0.3 kg (mean +/- s.e.m.) of body weight during the 3-week hypocaloric diet period. The 24-hour blood pressure did not differ between the last period of the standard diet and the first period of the hypocaloric diet; however, it showed a significant reduction after 3 weeks of the hypocaloric diet. The decrease in the 24-hour blood pressure during the study period was 10.5+/-1.5 mm Hg systole and 4.3+/-1.8 mm Hg diastole. In contrast, the 24-hour heart rate was significantly reduced in the first period of the hypocaloric diet, although the body weight and blood pressure did not change, and the rate was maintained even in the last period of the hypocaloric diet. The decrease in the 24-hour heart rate during the study period was 2.8+/-0.9 beats per minute. The hypocaloric diet did not change any autonomic indices obtained from a power spectral analysis of the heart-rate variability. In conclusion, different responses to a hypocaloric diet were observed between the blood pressure and the heart rate in obese hypertensive patients. The changes in

  13. Performance of the Automated Self-Administered 24-hour Recall relative to a measure of true intakes and to an interviewer-administered 24-h recall123

    PubMed Central

    Kirkpatrick, Sharon I; Subar, Amy F; Douglass, Deirdre; Zimmerman, Thea P; Thompson, Frances E; Kahle, Lisa L; George, Stephanie M; Dodd, Kevin W; Potischman, Nancy

    2014-01-01

    Background: The Automated Self-Administered 24-hour Recall (ASA24), a freely available Web-based tool, was developed to enhance the feasibility of collecting high-quality dietary intake data from large samples. Objective: The purpose of this study was to assess the criterion validity of ASA24 through a feeding study in which the true intake for 3 meals was known. Design: True intake and plate waste from 3 meals were ascertained for 81 adults by inconspicuously weighing foods and beverages offered at a buffet before and after each participant served him- or herself. Participants were randomly assigned to complete an ASA24 or an interviewer-administered Automated Multiple-Pass Method (AMPM) recall the following day. With the use of linear and Poisson regression analysis, we examined the associations between recall mode and 1) the proportions of items consumed for which a match was reported and that were excluded, 2) the number of intrusions (items reported but not consumed), and 3) differences between energy, nutrient, food group, and portion size estimates based on true and reported intakes. Results: Respondents completing ASA24 reported 80% of items truly consumed compared with 83% in AMPM (P = 0.07). For both ASA24 and AMPM, additions to or ingredients in multicomponent foods and drinks were more frequently omitted than were main foods or drinks. The number of intrusions was higher in ASA24 (P < 0.01). Little evidence of differences by recall mode was found in the gap between true and reported energy, nutrient, and food group intakes or portion sizes. Conclusions: Although the interviewer-administered AMPM performed somewhat better relative to true intakes for matches, exclusions, and intrusions, ASA24 performed well. Given the substantial cost savings that ASA24 offers, it has the potential to make important contributions to research aimed at describing the diets of populations, assessing the effect of interventions on diet, and elucidating diet and health

  14. Sex and age-related differences in performance in a 24-hour ultra-cycling draft-legal event – a cross-sectional data analysis

    PubMed Central

    2014-01-01

    Background The purpose of this study was to examine the sex and age-related differences in performance in a draft-legal ultra-cycling event. Methods Age-related changes in performance across years were investigated in the 24-hour draft-legal cycling event held in Schötz, Switzerland, between 2000 and 2011 using multi-level regression analyses including age, repeated participation and environmental temperatures as co-variables. Results For all finishers, the age of peak cycling performance decreased significantly (β = −0.273, p = 0.036) from 38 ± 10 to 35 ± 6 years in females but remained unchanged (β = −0.035, p = 0.906) at 41.0 ± 10.3 years in males. For the annual fastest females and males, the age of peak cycling performance remained unchanged at 37.3 ± 8.5 and 38.3 ± 5.4 years, respectively. For all female and male finishers, males improved significantly (β = 7.010, p = 0.006) the cycling distance from 497.8 ± 219.6 km to 546.7 ± 205.0 km whereas females (β = −0.085, p = 0.987) showed an unchanged performance of 593.7 ± 132.3 km. The mean cycling distance achieved by the male winners of 960.5 ± 51.9 km was significantly (p < 0.001) greater than the distance covered by the female winners with 769.7 ± 65.7 km but was not different between the sexes (p > 0.05). The sex difference in performance for the annual winners of 19.7 ± 7.8% remained unchanged across years (p > 0.05). The achieved cycling distance decreased in a curvilinear manner with advancing age. There was a significant age effect (F = 28.4, p < 0.0001) for cycling performance where the fastest cyclists were in age group 35–39 years. Conclusion In this 24-h cycling draft-legal event, performance in females remained unchanged while their age of peak cycling performance decreased and performance in males improved while their age of peak cycling performance remained unchanged. The annual fastest females and males were 37.3 ± 8.5 and 38.3 ± 5.4 years old, respectively. The sex

  15. The evolution of ambulatory ECG monitoring.

    PubMed

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health.

  16. Preliminary report: the effect of a 6-month dietary glycemic index manipulation in addition to healthy eating advice and weight loss on arterial compliance and 24-hour ambulatory blood pressure in men: a pilot study.

    PubMed

    Philippou, Elena; Bovill-Taylor, Candace; Rajkumar, Chakravarthi; Vampa, Maria Luisa; Ntatsaki, Eleana; Brynes, Audrey E; Hickson, Mary; Frost, Gary S

    2009-12-01

    We aimed to determine whether altering dietary glycemic index (GI) in addition to healthy eating and weight loss advice affects arterial compliance and 24-hour blood pressure (BP), both coronary heart disease (CHD) risk factors. Middle-aged men with at least 1 CHD risk were randomized to a 6-month low-GI (LGI) or high-GI (HGI) diet. All were advised on healthy eating and weight loss. They were seen monthly to assess dietary compliance and anthropometrics. Carotid-femoral pulse wave velocity (PWV), fasting blood lipid profile, and glucose and insulin concentrations were measured at baseline and at months 3 and 6. Six-hour postprandial glucose and insulin responses and 24-hour ambulatory BP were also assessed at baseline and month 6. Thirty-eight subjects (HGI group, n = 16; LGI group, n = 22) completed the study. At month 6, groups differed in dietary GI, glycemic load, and carbohydrate intake (P < .001). Fasting insulin concentration and insulin resistance (calculated by homeostatic model assessment) were lower in the LGI than the HGI group (P < .01). The reduction in total cholesterol and 24-hour BP was bigger in the LGI than the HGI group (P < .05); and only the LGI group had significant reductions (P < .05) in PWV, low-density lipoprotein cholesterol, and triacylglycerol concentration. There were no differences in postprandial glucose or insulin responses between the groups. The results suggest that an LGI diet may be more beneficial in reducing CHD risk, including PWV and 24-hour BP, even in the setting of healthy eating and weight loss; and thus, further study is warranted.

  17. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concentration in the acid gas from the sweetening unit for each 24-hour period: At least one sample per 24-hour... require a more frequent sampling schedule. (3) The average acid gas flow rate from the sweetening unit... rate of acid gas. The monitoring device reading shall be recorded at least once per hour during each...

  18. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy.

    PubMed

    Akintola, Abimbola A; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93-56.45%) and within (range 0.75-9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was -2.8, -1.0, and -0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed at

  19. Comparative Analysis of the Equivital EQ02 Lifemonitor with Holter Ambulatory ECG Device for Continuous Measurement of ECG, Heart Rate, and Heart Rate Variability: A Validation Study for Precision and Accuracy

    PubMed Central

    Akintola, Abimbola A.; van de Pol, Vera; Bimmel, Daniel; Maan, Arie C.; van Heemst, Diana

    2016-01-01

    Background: The Equivital (EQ02) is a multi-parameter telemetric device offering both real-time and/or retrospective, synchronized monitoring of ECG, HR, and HRV, respiration, activity, and temperature. Unlike the Holter, which is the gold standard for continuous ECG measurement, EQO2 continuously monitors ECG via electrodes interwoven in the textile of a wearable belt. Objective: To compare EQ02 with the Holter for continuous home measurement of ECG, heart rate (HR), and heart rate variability (HRV). Methods: Eighteen healthy participants wore, simultaneously for 24 h, the Holter and EQ02 monitors. Per participant, averaged HR, and HRV per 5 min from the two devices were compared using Pearson correlation, paired T-test, and Bland-Altman analyses. Accuracy and precision metrics included mean absolute relative difference (MARD). Results: Artifact content of EQ02 data varied widely between (range 1.93–56.45%) and within (range 0.75–9.61%) participants. Comparing the EQ02 to the Holter, the Pearson correlations were respectively 0.724, 0.955, and 0.997 for datasets containing all data and data with < 50 or < 20% artifacts respectively. For datasets containing respectively all data, data with < 50, or < 20% artifacts, bias estimated by Bland-Altman analysis was −2.8, −1.0, and −0.8 beats per minute and 24 h MARD was 7.08, 3.01, and 1.5. After selecting a 3-h stretch of data containing 1.15% artifacts, Pearson correlation was 0.786 for HRV measured as standard deviation of NN intervals (SDNN). Conclusions: Although the EQ02 can accurately measure ECG and HRV, its accuracy and precision is highly dependent on artifact content. This is a limitation for clinical use in individual patients. However, the advantages of the EQ02 (ability to simultaneously monitor several physiologic parameters) may outweigh its disadvantages (higher artifact load) for research purposes and/ or for home monitoring in larger groups of study participants. Further studies can be aimed

  20. Cross sectional longitudinal study of spot morning urine protein:creatinine ratio, 24 hour urine protein excretion rate, glomerular filtration rate, and end stage renal failure in chronic renal disease in patients without diabetes.

    PubMed Central

    Ruggenenti, P.; Gaspari, F.; Perna, A.; Remuzzi, G.

    1998-01-01

    OBJECTIVE: To evaluate whether the protein:creatinine ratio in spot morning urine samples is a reliable indicator of 24 hour urinary protein excretion and predicts the rate of decline of glomerular filtration rate and progression to end stage renal failure in non-diabetic patients with chronic nephropathy. DESIGN: Cross sectional correlation between the ratio and urinary protein excretion rate. Univariate and multivariate analysis of baseline predictors, including the ratio and 24 hour urinary protein, of decline in glomerular filtration rate and end stage renal failure in the long term. SETTING: Research centre in Italy. SUBJECTS: 177 non-diabetic outpatients with chronic renal disease screened for participation in the ramipril efficacy in nephropathy study. MAIN OUTCOME MEASURES: Rate of decline in filtration rate evaluated by repeated measurements of unlabelled iohexol plasma clearance and rate of progression to renal failure. RESULTS: Protein:creatinine ratio was significantly correlated with absolute and log transformed 24 hour urinary protein values (P = 0.0001 and P < 0.0001, respectively.) Ratios also had high predictive value for rate of decline of the glomerular filtration rate (univariate P = 0.0003, multivariate P = 0.004) and end stage renal failure (P = 0.002 and P = 0.04). Baseline protein:creatinine ratios and rate of decline of the glomerular filtration rate were also significantly correlated (P < 0.0005). In the lowest third of the protein:creatinine ratio (< 1.7) there was 3% renal failure compared with 21.2% in the highest third (> 2.7) (P < 0.05). CONCLUSIONS: Protein:creatinine ratio in spot morning urine samples is a precise indicator of proteinuria and a reliable predictor of progression of disease in non-diabetic patients with chronic nephropathies and represents a simple and inexpensive procedure in establishing severity of renal disease and prognosis. PMID:9501711

  1. Index Blood Tests and National Early Warning Scores within 24 Hours of Emergency Admission Can Predict the Risk of In-Hospital Mortality: A Model Development and Validation Study

    PubMed Central

    Mohammed, Mohammed A.; Rudge, Gavin; Watson, Duncan; Wood, Gordon; Smith, Gary B.; Prytherch, David R.; Girling, Alan; Stevens, Andrew

    2013-01-01

    Background We explored the use of routine blood tests and national early warning scores (NEWS) reported within ±24 hours of admission to predict in-hospital mortality in emergency admissions, using empirical decision Tree models because they are intuitive and may ultimately be used to support clinical decision making. Methodology A retrospective analysis of adult emergency admissions to a large acute hospital during April 2009 to March 2010 in the West Midlands, England, with a full set of index blood tests results (albumin, creatinine, haemoglobin, potassium, sodium, urea, white cell count and an index NEWS undertaken within ±24 hours of admission). We developed a Tree model by randomly splitting the admissions into a training (50%) and validation dataset (50%) and assessed its accuracy using the concordance (c-) statistic. Emergency admissions (about 30%) did not have a full set of index blood tests and/or NEWS and so were not included in our analysis. Results There were 23248 emergency admissions with a full set of blood tests and NEWS with an in-hospital mortality of 5.69%. The Tree model identified age, NEWS, albumin, sodium, white cell count and urea as significant (p<0.001) predictors of death, which described 17 homogeneous subgroups of admissions with mortality ranging from 0.2% to 60%. The c-statistic for the training model was 0.864 (95%CI 0.852 to 0.87) and when applied to the testing data set this was 0.853 (95%CI 0.840 to 0.866). Conclusions An easy to interpret validated risk adjustment Tree model using blood test and NEWS taken within ±24 hours of admission provides good discrimination and offers a novel approach to risk adjustment which may potentially support clinical decision making. Given the nature of the clinical data, the results are likely to be generalisable but further research is required to investigate this promising approach. PMID:23734195

  2. Improved Oxygenation 24 Hours After Transition to Airway Pressure Release Ventilation or High-Frequency Oscillatory Ventilation Accurately Discriminates Survival in Immunocompromised Pediatric Patients With Acute Respiratory Distress Syndrome*

    PubMed Central

    Yehya, Nadir; Topjian, Alexis A.; Thomas, Neal J.; Friess, Stuart H.

    2014-01-01

    Objectives Children with an immunocompromised condition and requiring invasive mechanical ventilation have high risk of death. Such patients are commonly transitioned to rescue modes of non-conventional ventilation, including airway pressure release ventilation and high-frequency oscillatory ventilation, for acute respiratory distress syndrome refractory to conventional ventilation. Our aim was to describe our experience with airway pressure release ventilation and high-frequency oscillatory ventilation in children with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation and to identify factors associated with survival. Design Retrospective cohort study. Setting Tertiary care, university-affiliated PICU. Patients Sixty pediatric patients with an immunocompromised condition and acute respiratory distress syndrome refractory to conventional ventilation transitioned to either airway pressure release ventilation or high-frequency oscillatory ventilation. Interventions None. Measurements and Main Results Demographic data, ventilator settings, arterial blood gases, oxygenation index, and Pao2/Fio2 were recorded before transition to either mode of nonconventional ventilation and at predetermined intervals after transition for up to 5 days. Mortality in the entire cohort was 63% and did not differ between patients transitioned to airway pressure release ventilation and high-frequency oscillatory ventilation. For both airway pressure release ventilation and high-frequency oscillatory ventilation, improvements in oxygenation index and Pao2/Fio2 at 24 hours expressed as a fraction of pretransition values (oxygenation index24/oxygenation indexpre and Pao2/Fio224/Pao2/FIO2pre) reliably discriminated nonsurvivors from survivors, with receiver operating characteristic areas under the curves between 0.89 and 0.95 (p for all curves < 0.001). Sensitivity-specificity analysis suggested that less than 15% reduction in

  3. Differential Gene Expression in Explanted Human Retinal Pigment Epithelial Cells 24-Hours Post-Exposure to 532 nm, 3.0 ns Pulsed Laser Light and 1064 nm, 170 ps Pulsed Laser Light 12-Hours Post-Exposure: Results Compendium

    DTIC Science & Technology

    2004-06-01

    Laser Light and 1064 nm, 170 ps Pulsed Laser Light 12-hours Post-Exposure: Results Compendium John W. Obringer Martin D. Johnson Laser and Optics...Explanted Human Retinal Pigment Epithelial Cells 12-hours Post-Exposure to 532 nm, 3.0 ns Pulsed Laser Light and 1064 nm, 170 ps Pulsed Laser Lightl2-hours...Explanted Human Retinal Pigment Epithelial USAFA F05611-02-P-0471 Cells 24-Hours Post-Exposure to 532 nm, 3.0 ns Pulsed Laser-Light and 1064nm, 170 ps Pulsed

  4. Association of uremic pruritus in hemodialysis patients with the number of days of high mean 24-hour particulate matter with a diameter of <2.5 μm

    PubMed Central

    Liu, Ming-Hui; Chan, Ming-Jen; Hsu, Ching-Wei; Weng, Cheng-Hao; Yen, Tzung-Hai; Huang, Wen-Hung

    2017-01-01

    Uremic pruritus (UP) is a common and incapacitating symptom in patients undergoing hemodialysis (HD). The pathogenesis of UP is multifactorial and complex. Particulate matter (PM), a major air pollutant, is a mixture of particles with various chemical compositions. PM is associated with several allergic diseases, including dermatitis. To assess the role of PM (PM with a diameter of <10 μm [PM10] and PM with a diameter of <2.5 μm [PM2.5]) and other clinical variables in UP in patients on HD, we recruited 866 patients on maintenance HD (MHD). We analyzed the number of days of mean 24-hour PM10 ≥125 μg/m3/12 months (NDPM10) or the number of days of mean 24-hour PM2.5 ≥35 μg/m3/12 months (NDPM2.5) exceeding the standard level in the past 12 months respectively to determine the association with UP. In a multivariate logistic regression, HD duration, serum ferritin levels, low-density lipoprotein (LDL) levels, and NDPM2.5 ≥116 days/12 months were positively associated with UP. This cross-sectional study showed that the number of days on which the environmental PM2.5 exceeds the standard level might be associated with UP in patients on MHD. PMID:28260912

  5. 24-hour urinary aldosterone excretion test

    MedlinePlus

    ... sodium is in your diet Whether your kidneys work properly The condition being diagnosed Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your doctor ...

  6. FREQUENCY DISTRIBUTIONS AND SPATIAL ANALYSIS OF FINE PARTICLE MEASUREMENTS IN ST. LOUIS DURING THE REGIONAL AIR POLLUTION STUDY/REGIONAL AIR MONITORING SYSTEM

    EPA Science Inventory

    Community, time-series epidemiology typically uses either 24-hour integrated particulate matter (PM) concentrations averaged across several monitors in a city or data obtained at a central monitoring site to relate PM concentrations to human health effects. If 24-hour integrated...

  7. A real-time ECG data compression algorithm for a digital holter system.

    PubMed

    Lee, Sangjoon; Lee, Myoungho

    2008-01-01

    This paper describes a real time ECG compression algorithm for a digital holter system. Proposed algorithm consists of five main procedures. First procedure is to differentiate signals, second is to choose a period of the differentiated signals and store them in memory, third is to perform the DCT(Discrete Cosine Transform) on the stored data, fourth is to apply a window filter, and fifth procedure is to apply Huffman Coding compression method on the data. This developed algorithm has been tested by applying 12 ECGs(electrocardiograms) from the MIT-BIH database and the PRD(Percent RMS Difference) and the CR(Compression Ratio) are calculated. It is found that the algorithm achieved a high level of compression performance with 1.82 of PRD and 8.82:1 of CR in average.

  8. Patterns of physical activity defined by continuous heart rate monitoring among children from Liège.

    PubMed

    Massin, M M; Bourguignont, A; Lepage, Ph; Gérard, P

    2004-01-01

    Health benefits of a physically active lifestyle are well documented. We therefore investigated the physical activity patterns of 200 children from Liège. They were monitored continuously using a 24-hour Holter monitoring system during normal weekdays and the percentage of heart rate reserve (%HRR) was used to measure the amounts of physical activity at different intensities. Preschool children attained 184.3+/-54.2, 40.7+/-16.1, 15.8+/-6.9 and 6.0+/-7.2 minutes/day (mean+/-SD) between 20% to 40%, 40% to 50%, 50% to 60%, and greater than 60% of HRR, respectively. At the same %HRR intensities, schoolchildren attained 165.6+/-74.6, 32.1+/-12.1, 15.8+/-6.7 and 7.0+/-5.9 minutes/day, and teenagers attained 159.2+/-68.3, 32.1+/-23.5, 13.1+/-6.0 and 6.1+/-6.3 minutes/day. Age was a significant predictor of the intercept and slope of the time spent in physical activity and %HRR relationship. In Liège the average youth accumulates +/-30 to 40 minutes/day of moderate-intensity physical activity and +/-20 minutes/day of high-intensity physical activity. Those children meet the classical revised guidelines for physical activity but do not compare favourably with children from elsewhere. On the other hand, they get more than 2 1/2 to 3 hours/day of low-intensity physical activity. Our findings suggest that children from Liège are not engaged in sedentary behaviour but do not experience the ideal amount and type of physical activity classically believed to benefit the cardiopulmonary system. Public health strategies should be adapted to our findings.

  9. Comparison of thrombolysis in myocardial infarction, Global Registry of Acute Coronary Events, and Acute Physiology and Chronic Health Evaluation II risk scores in patients with acute myocardial infarction who require mechanical ventilation for more than 24 hours.

    PubMed

    Eran, Oren; Novack, Victor; Gilutz, Harel; Zahger, Doron

    2011-02-01

    The ability to provide an accurate prognosis in an intensive care unit is of major importance. Numerous risk scores have been developed to predict hospital mortality based on demographic, physiologic, and clinical data. These scores were universally developed in general medical or surgical intensive care units. Patients admitted to a cardiac care unit differ in many aspects from those admitted to general medical intensive care units. Few patients require mechanical ventilation and prolonged intensive care. Performance of risk scores developed for patients with acute myocardial infarction (AMI) in this subgroup is unknown. We prospectively studied 51 consecutive patients who were admitted to a cardiac care unit from September 2006 to March 2008 for AMI and received mechanical ventilation for >24 hours. Acute Physiology and Chronic Health Evaluation II (APACHE II), Thrombolysis In Myocardial Infarction, and Global Registry of Acute Coronary Events risk scores were calculated for each patient. Mortality rates were extrapolated based on these 3 risk scores. Twenty-two of 51 patients (43%) died in hospital. Age, mean arterial pressure, urea, albumin, hemoglobin, need for vasopressors, and estimated glomerular filtration rate were predictive of mortality. APACHE II and Global Registry of Acute Coronary Events scores were higher in nonsurvivors but Thrombolysis In Myocardial Infarction risk score was not predictive of mortality. APACHE II score had the highest value for area under receiver operator characteristics curve for mortality prediction. In conclusion, patients with AMI requiring mechanical ventilation have a high mortality rate. This risk is predicted by co-morbidities better than by direct cardiac parameters. Consequently, conventional AMI risk scores do not perform well in this very sick population and the APACHE II score better predicts their short-term outcome.

  10. Temporal Differential Gene Expression in Explanted Human Retinal Pigment Epithelial Cells at 0.5, 1.0, 3.0, 6.0, 12 and 24 Hours Post-Exposure to 1064 nm, 3.6 ns Pulsed Laser Light

    DTIC Science & Technology

    2005-05-01

    USAFA TR 2005-05 Temporal Differential Gene Expression in Explanted Human Retinal Pigment Epithelial Cells at 0.5, 1.0, 3.0, 6.0, 12 and 24 Hours...AIR FORCE ACADEMY COLORADO 80840 20050630 417 USAFA TR 2005-05 This article, "Temporal Differential Gene Expression in Explanted Human Retinal ...Differential Gene Expression in Explanted Human Retinal Pigment USAFA F05611-02-P-0471 Epithelial Cells at 0.5, 1.0, 3.0, 6.0, 12 and 24-Hours Post-Exposure

  11. Evaluation of repolarization dynamics using the QT-RR regression line slope and intercept relationship during 24-h Holter ECG.

    PubMed

    Fujiki, Akira; Yoshioka, Ryozo; Sakabe, Masao

    2015-03-01

    QT-RR linear regression consists of two parameters, slope and intercept, and the aim of this study was to evaluate repolarization dynamics using the QT-RR linear regression slope and intercept relationship during 24-h Holter ECG. This study included 466 healthy subjects (54.6 ± 14.6 years; 200 men and 266 women) and 17 patients with ventricular arrhythmias, consisted of 10 patients with idiopathic ventricular fibrillation (IVF) and 7 patients with torsades de pointes (TDP). QT and RR intervals were measured from ECG waves based on a 15-s averaged ECG during 24-h Holter recording using an automatic QT analyzing system. The QT interval dependence on the RR interval was analyzed using a linear regression line for each subject ([QT] = A[RR] + B; where A is the slope and B is the y-intercept). The slope of the QT-RR regression line in healthy subjects was significantly greater in women than in men (0.185 ± 0.036 vs. 0.161 ± 0.033, p < 0.001) and the intercept was significantly smaller in women than in men (0.229 ± 0.028 vs. 0.240 ± 0.027, p < 0.001). A scatter diagram of the QT-RR regression line slope and intercept among healthy subjects demonstrated a statistically significant negative correlation (B = -0.62A + 0.34, r = -0.79). Distribution of both scatter diagrams of the slope and the intercept of the QT-RR regression line in patients with IVF and TDP was different from healthy subjects (left corner for IVF and upward shift for TDP). The slope and intercept relationship of the QT-RR linear regression line based on 24-h Holter ECG may become a simple useful marker for abnormality of ventricular repolarization dynamics.

  12. 40 CFR 60.45 - Emissions and fuel monitoring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... opacity monitoring system (COMS) for measuring opacity and a CEMS for measuring SO2 emissions, NOX... initiate investigation of the relevant equipment and control systems within 24 hours of the first discovery... tests, elect to perform subsequent monitoring using a digital opacity compliance system according to...

  13. 30 CFR 75.336 - Sampling and monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... monitoring requirements. (a) A certified person as defined in § 75.100 shall monitor atmospheres of sealed... sampled at least every 24 hours. (i) Atmospheres with seals of 120 psi or greater shall be sampled until the design strength is reached for every seal used to seal the area. (ii) Atmospheres with seals...

  14. 30 CFR 75.336 - Sampling and monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring requirements. (a) A certified person as defined in § 75.100 shall monitor atmospheres of sealed... sampled at least every 24 hours. (i) Atmospheres with seals of 120 psi or greater shall be sampled until the design strength is reached for every seal used to seal the area. (ii) Atmospheres with seals...

  15. 40 CFR 61.55 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for Mercury § 61.55 Monitoring of emissions and operations. (a) Wastewater treatment plant sludge incineration and drying plants. All the sources for which mercury emissions exceed 1.6 kg (3.5 lb) per 24-hour....54, shall monitor mercury emissions at intervals of at least once per year by use of Method 105...

  16. 40 CFR 61.55 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for Mercury § 61.55 Monitoring of emissions and operations. (a) Wastewater treatment plant sludge incineration and drying plants. All the sources for which mercury emissions exceed 1.6 kg (3.5 lb) per 24-hour....54, shall monitor mercury emissions at intervals of at least once per year by use of Method 105...

  17. 30 CFR 75.336 - Sampling and monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... specific levels of methane, carbon dioxide, nitrogen and oxygen; the sampling methods and equipment used... monitoring requirements. (a) A certified person as defined in § 75.100 shall monitor atmospheres of sealed... sampled at least every 24 hours. (i) Atmospheres with seals of 120 psi or greater shall be sampled...

  18. Long-term invariant parameters obtained from 24-h Holter recordings: A comparison between different analysis techniques

    NASA Astrophysics Data System (ADS)

    Cerutti, Sergio; Esposti, Federico; Ferrario, Manuela; Sassi, Roberto; Signorini, Maria Gabriella

    2007-03-01

    Over the last two decades, a large number of different methods had been used to study the fractal-like behavior of the heart rate variability (HRV). In this paper some of the most used techniques were reviewed. In particular, the focus is set on those methods which characterize the long memory behavior of time series (in particular, periodogram, detrended fluctuation analysis, rescale range analysis, scaled window variance, Higuchi dimension, wavelet-transform modulus maxima, and generalized structure functions). The performances of the different techniques were tested on simulated self-similar noises (fBm and fGn) for values of α, the slope of the spectral density for very small frequency, ranging from -1 to 3 with a 0.05 step. The check was performed using the scaling relationships between the various indices. DFA and periodogram showed the smallest mean square error from the expected values in the range of interest for HRV. Building on the results obtained from these tests, the effective ability of the different methods in discriminating different populations of patients from RR series derived from Holter recordings, was assessed. To this extent, the Noltisalis database was used. It consists of a set of 30, 24-h Holter recordings collected from healthy subjects, patients suffering from congestive heart failure, and heart transplanted patients. All the methods, with the exception at most of rescale range analysis, were almost equivalent in distinguish between the three groups of patients. Finally, the scaling relationships, valid for fBm and fGn, when empirically used on HRV series, also approximately held.

  19. Effects of a canine Elizabethan collar on ambulatory electrocardiogram recorded by a Holter recording system and spontaneous activities measured continuously by an accelerometer in Beagle dogs.

    PubMed

    Yamada, M; Tokuriki, M

    2000-05-01

    Ambulatory electrocardiogram (ECG) has been recorded in dogs wearing a jacket to protect a Holter recording system, but the jacket was often damaged by dogs. We compared ECG recorded by a Holter recording system and spontaneous activity measured by an accelerometer in Beagle dogs with or without an Elizabethan collar. There were few significant differences in mean values (per hr) of the heart rate and the amount of spontaneous activity between dogs with or without the Elizabethan collar. Mean values (per 23 hr) of them had no significant difference between them. We concluded that the Elizabethan collar did not have any effect on ambulatory ECG and canine movements and was effective to protect the recording apparatus.

  20. Microbial Load Monitor

    NASA Technical Reports Server (NTRS)

    Gibson, S. F.; Royer, E. R.

    1979-01-01

    The Microbial Load Monitor (MLM) is an automated and computerized system for detection and identification of microorganisms. Additionally, the system is designed to enumerate and provide antimicrobic susceptibility profiles for medically significant bacteria. The system is designed to accomplish these tasks in a time of 13 hours or less versus the traditional time of 24 hours for negatives and 72 hours or more for positives usually required for standard microbiological analysis. The MLM concept differs from other methods of microbial detection in that the system is designed to accept raw untreated clinical samples and to selectively identify each group or species that may be present in a polymicrobic sample.

  1. Monitoring

    SciTech Connect

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2004-11-23

    The invention provides apparatus and methods which facilitate movement of an instrument relative to an item or location being monitored and/or the item or location relative to the instrument, whilst successfully excluding extraneous ions from the detection location. Thus, ions generated by emissions from the item or location can successfully be monitored during movement. The technique employs sealing to exclude such ions, for instance, through an electro-field which attracts and discharges the ions prior to their entering the detecting location and/or using a magnetic field configured to repel the ions away from the detecting location.

  2. Sun Blasts 6 CMEs in 24 Hour Period

    NASA Video Gallery

    This movie from the chronograph on board the SOlar and Heliospheric Observatory (SOHO), shows the sun's atmosphere – the corona – from September 17 to September 20. The sun let loose with at ...

  3. Rethinking the Youth Weight Debate: The 24 Hour Day

    ERIC Educational Resources Information Center

    Dodd, Graham; Biggs, Sarah; Agley, Daniel; Dollman, James; Lushington, Kurt

    2008-01-01

    Approaches to weight management have traditionally focussed on caloric intake versus caloric expenditure. Despite a range of interventions based on these approaches, the proportion of overweight children and adolescents continues to rise. There are increasing indications that other factors, such as sleep duration, may be at play. This commentary…

  4. Newborn Infants' Memory for Speech Sounds Retained over 24 Hours.

    ERIC Educational Resources Information Center

    Swain, Irina U.; And Others

    1993-01-01

    Neonates who were exposed to the same or different words on two consecutive days habituated to the sound on day one and recovered head turning on day two. Infants who heard the same word again on day two responded less well than infants exposed to the word for the first time on day two. (BC)

  5. Knighthelm 24-hour HMD: from development to production

    NASA Astrophysics Data System (ADS)

    White, John; Cameron, Alexander A.

    2001-08-01

    The BAE SYSTEMS Knighthelm HMD is a unique two-part helmet design, using a form fitted inner helmet with an outer display module. It has been refined and enhanced, as part of an extensive development program, for the German Army Tiger helicopter, and is optimized for the attack helicopter application. The design optically mixes the output of an Image Intensifier Tube with Cathode Ray Tube imagery. This provides a flexible display of symbology overlaid on NVG imagery or symbology overlaid on FLIR video viewed as a collimated image in the see through combiner eyepiece in front of the users eyes.

  6. Perceptually relevant remapping of human somatotopy in 24 hours

    PubMed Central

    Kolasinski, James; Makin, Tamar R; Logan, John P; Jbabdi, Saad; Clare, Stuart; Stagg, Charlotte J; Johansen-Berg, Heidi

    2016-01-01

    Experience-dependent reorganisation of functional maps in the cerebral cortex is well described in the primary sensory cortices. However, there is relatively little evidence for such cortical reorganisation over the short-term. Using human somatosensory cortex as a model, we investigated the effects of a 24 hr gluing manipulation in which the right index and right middle fingers (digits 2 and 3) were adjoined with surgical glue. Somatotopic representations, assessed with two 7 tesla fMRI protocols, revealed rapid off-target reorganisation in the non-manipulated fingers following gluing, with the representation of the ring finger (digit 4) shifted towards the little finger (digit 5) and away from the middle finger (digit 3). These shifts were also evident in two behavioural tasks conducted in an independent cohort, showing reduced sensitivity for discriminating the temporal order of stimuli to the ring and little fingers, and increased substitution errors across this pair on a speeded reaction time task. DOI: http://dx.doi.org/10.7554/eLife.17280.001 PMID:28035900

  7. Detection of sleep bruxism: comparison between an electromyographic and electrocardiographic portable holter and polysomnography.

    PubMed

    Castroflorio, T; Deregibus, A; Bargellini, A; Debernardi, C; Manfredini, D

    2014-03-01

    Recent polysomnographic (PSG) studies showed that the sleep bruxism (SB) event is preceded by a sudden shift in autonomic cardiac activity. Therefore, heart rate could be the simplest-to-record parameter for use in addition to portable home EMG monitoring to improve the accuracy in automatic detection of SB events. The aim of the study was to compare the detection of SB episodes by combined surface electromyography and heart rate (HR) recorded by a compact portable device (Bruxoff(®) ), with the scoring of SB episodes by a PSG recording. Twenty-five subjects (14 'probable' bruxers and 11 non-bruxers) were selected for the study. Each subject underwent the Bruxoff and the PSG recordings during the same night. Rhythmic masseter muscle activities (RMMAs) were scored according to published criteria. Correlation coefficients and the Bland-Altman plots were calculated to measure the correlation and agreement between the two methods. Results showed a high correlation (Pearson's r = 0·95, P < 0·0001) and a high agreement (bias = 0·05) between Bruxoff and the PSG. Furthermore, the receiver operating characteristic curve analysis showed a high sensitivity and specificity of the portable device (92·3% and 91·6%, respectively) when the cut-off was set at 4 SB episodes per hour according to published criteria. The Bruxoff device showed a good diagnostic accuracy to differentiate RMMA from other oromotor activities. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.

  8. The impact of fertilization on the chicken egg yolk plasma and granule proteome 24 hours post-lay at room temperature: capitalizing on high-pH/low-pH reverse phase chromatography in conjunction with tandem mass tag (TMT) technology.

    PubMed

    Padliya, Neerav D; Qian, Meiqian; Mimi Roy, Sushmita; Chu, Patrick; Zheng, Haiyan; Tess, Alex; Dariani, Maghsoud; Hariri, Robert J

    2015-07-01

    Chicken egg yolk is a rich source of nutrients providing high quality proteins, vitamins, minerals, carotenoids and antioxidants. Chicken egg yolk, recovered from whole egg within 24 hours post-lay has been utilized as a starting material in the preparation of a dietary supplement that has been demonstrated to lead to gains in muscle mass in a human clinical study. Further, an oil derived from chicken egg yolk has been utilized as a topical agent to treat third degree burn injury. The molecular changes that take place in fertilized, chicken egg yolk during the first 24 hours post-lay are not well understood. By studying how the protein composition of egg yolk varies with fertility status, one can utilize this knowledge to develop egg yolk-based products that have been optimized for specific applications. In this study, a direct quantitative comparison was made between the proteome of fertilized chicken egg yolk and the proteome of unfertilized chicken egg yolk, both maintained at 20 °C and analyzed within 24 hours post-lay. Egg yolk proteins from each fertility state were digested with trypsin, labeled with distinct chemical labels (tandem mass tag reagents) and then combined in a 1 : 1 ratio. A TMT-labeled tryptic digest derived from chicken egg yolk proteins (fertilized and unfertilized) was separated using high-pH/low-pH reverse-phase chromatography and analyzed using mass spectrometry. 225 protein identifications were made from this TMT-labeled tryptic digest based on a minimum of 2 unique peptides observed per protein. 9 proteins increased in abundance in fertilized egg yolk relative to unfertilized egg yolk and 9 proteins decreased in abundance in fertilized egg yolk relative to unfertilized egg yolk. Some proteins that increased in abundance in fertilized egg yolk play an important role in angiogenesis (pleiotrophin, histidine rich glycoprotein) and defense against pathogens (mannose-binding lectin, β-defensin 11, serum amyloid P-component, ovostatin

  9. Explanation of prerequisites for patient monitoring

    NASA Astrophysics Data System (ADS)

    Kessler, Manfred D.; Singer, Michael; Rauh, Robert

    2002-06-01

    Long-term conservation of organs by use of hemoglobin-free perfusion of tissue can be applied during heart surgery as well as transplantation of kidney, liver and pancreas. Furthermore, a conservation of organs during times of 24 hours can be very useful for transport of organs in order to prevent reperfusion injury. Decisive prerequisites for the application of such new tools is the applicability of modern optical tissue sensors for precise monitoring of local tissue function.

  10. Quasi Real Time Data Analysis for Air Quality Monitoring with an Electronic Nose

    NASA Technical Reports Server (NTRS)

    Zhou, Hanying; Shevade, Abhijit V.; Pelletier, Christine C.; Homer, Margie L.; Ryan, M. Amy

    2006-01-01

    Cabin Air Quality Monitoring: A) Functions; 1) Incident monitor for targeted contaminants exceeding targeted concentrations. Identify and quantify. 2) Monitor for presence of compounds associated with fires or overheating electronics. 3) Monitor clean-up process. B) Characteristics; 1) Low mass, low power device. 2) Requires little crew time for maintenance and calibration. 3) Detects, identifies and quantifies selected chemical species at or below 24 hour SMAC.

  11. Clinical Practice Guideline for the Treatment of Intrinsic Circadian Rhythm Sleep-Wake Disorders: Advanced Sleep-Wake Phase Disorder (ASWPD), Delayed Sleep-Wake Phase Disorder (DSWPD), Non-24-Hour Sleep-Wake Rhythm Disorder (N24SWD), and Irregular Sleep-Wake Rhythm Disorder (ISWRD). An Update for 2015

    PubMed Central

    Auger, R. Robert; Burgess, Helen J.; Emens, Jonathan S.; Deriy, Ludmila V.; Thomas, Sherene M.; Sharkey, Katherine M.

    2015-01-01

    A systematic literature review and meta-analyses (where appropriate) were performed and the GRADE approach was used to update the previous American Academy of Sleep Medicine Practice Parameters on the treatment of intrinsic circadian rhythm sleep-wake disorders. Available data allowed for positive endorsement (at a second-tier degree of confidence) of strategically timed melatonin (for the treatment of DSWPD, blind adults with N24SWD, and children/ adolescents with ISWRD and comorbid neurological disorders), and light therapy with or without accompanying behavioral interventions (adults with ASWPD, children/adolescents with DSWPD, and elderly with dementia). Recommendations against the use of melatonin and discrete sleep-promoting medications are provided for demented elderly patients, at a second- and first-tier degree of confidence, respectively. No recommendations were provided for remaining treatments/ populations, due to either insufficient or absent data. Areas where further research is needed are discussed. Citation: Auger RR, Burgess HJ, Emens JS, Deriy LV, Thomas SM, Sharkey KM. Clinical practice guideline for the treatment of intrinsic circadian rhythm sleep-wake disorders: advanced sleep-wake phase disorder (ASWPD), delayed sleep-wake phase disorder (DSWPD), non-24-hour sleep-wake rhythm disorder (N24SWD), and irregular sleep-wake rhythm disorder (ISWRD). An update for 2015. J Clin Sleep Med 2015;11(10):1199–1236. PMID:26414986

  12. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reduction efficiency achieved (R) shall be calculated for each 24-hour clock internal. The 24-hour interval may begin and end at any selected clock time, but must be consistent. The 24-hour average...

  13. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reduction efficiency achieved (R) shall be calculated for each 24-hour clock internal. The 24-hour interval may begin and end at any selected clock time, but must be consistent. The 24-hour average...

  14. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reduction efficiency achieved (R) shall be calculated for each 24-hour clock internal. The 24-hour interval may begin and end at any selected clock time, but must be consistent. The 24-hour average...

  15. 40 CFR 60.646 - Monitoring of emissions and operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reduction efficiency achieved (R) shall be calculated for each 24-hour clock internal. The 24-hour interval may begin and end at any selected clock time, but must be consistent. The 24-hour average...

  16. Ambulatory glucose profile: Flash glucose monitoring.

    PubMed

    Kalra, Sanjay; Gupta, Yashdeep

    2015-12-01

    Ambulatory glucose profile (AGP) is a novel way of assessing glycaemic levels on a 24 hour basis, through a minimally invasive method, known as flash glucose monitoring. This review describes the unique features of AGP, differentiates it from existing methods of glucose monitoring, and explains how it helps pursue the glycaemic pentad. The review suggests pragmatic usage of this technology, including pre-test, intra-test, and post-test counselling, and lists specific clinical scenarios where the investigation seems to be of immense benefit.

  17. Enhanced Raman Monitor Project

    NASA Technical Reports Server (NTRS)

    Westenskow, Dwayne

    1996-01-01

    Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

  18. Small Active Radiation Monitor

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.

    2004-01-01

    A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the

  19. WIPP Transparency Project - container tracking and monitoring demonstration using the Authenticated Tracking and Monitoring System (ATMS)

    SciTech Connect

    SCHOENEMAN, J. LEE; SMARTT, HEIDI ANNE; HOFER, DENNIS

    2000-01-27

    The Authenticated Tracking and Monitoring System (ATMS) is designed to answer the need for global monitoring of the status and location of proliferation-sensitive items on a worldwide basis, 24 hours a day. ATMS uses wireless sensor packs to monitor the status of the items within the shipment and surrounding environmental conditions. Receiver and processing units collect a variety of sensor event data that is integrated with GPS tracking data. The collected data are transmitted to the International Maritime Satellite (INMARSAT) communication system, which then sends the data to mobile ground stations. Authentication and encryption algorithms secure the data during communication activities. A typical ATMS application would be to track and monitor the stiety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements.

  20. Monitoring LMXBs with the Faulkes Telescope

    NASA Astrophysics Data System (ADS)

    Lewis, Fraser; Russell, D. M.; Fender, R. P.; Roche, P.

    The Faulkes Telescope Project is the educational arm of the Las Cumbres Observatory Global Telescope Network (LCOGT). It currently has two 2-metre robotic telescopes, located at Haleakala on Maui (FT North) and Siding Spring in Australia (FT South). It is planned to increase this to six 2-metre telescopes in the future, complemented by a network of 30-40 smaller (0.4 - 1 metre) telescopes providing 24 hour coverage of both northern and southern hemispheres. We are undertaking a monitoring project of 10 low-mass X-ray binaries (LMXBs) using FT North to study the optical continuum behaviour of X-ray transients in quiescence. The introduction of FT South in September 2006 allows us to extend this monitoring to include 17 southern hemisphere LMXBs. With new instrumentation, we also intend to expand this monitoring to include both infrared wavelengths and spectroscopy.

  1. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  2. 40 CFR 60.5407 - What are the requirements for monitoring of emissions and operations from my sweetening unit...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emission reduction efficiency achieved (R) for each 24-hour clock interval. The 24-hour interval may begin and end at any selected clock time, but must be consistent. You must compute the 24-hour...

  3. 40 CFR 60.5407 - What are the requirements for monitoring of emissions and operations from my sweetening unit...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... emission reduction efficiency achieved (R) for each 24-hour clock interval. The 24-hour interval may begin and end at any selected clock time, but must be consistent. You must compute the 24-hour...

  4. Monitoring and Detection Platform to Prevent Anomalous Situations in Home Care

    PubMed Central

    Villarrubia, Gabriel; Bajo, Javier; De Paz, Juan F.; Corchado, Juan M.

    2014-01-01

    Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost. PMID:24905853

  5. Monitoring and detection platform to prevent anomalous situations in home care.

    PubMed

    Villarrubia, Gabriel; Bajo, Javier; De Paz, Juan F; Corchado, Juan M

    2014-06-05

    Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost.

  6. Possible theoretical explanations for occasional days of non-field-aligned diffusion at neutron monitor energies

    NASA Technical Reports Server (NTRS)

    Forman, M. A.

    1975-01-01

    It has been shown previously (Anath et al., 1973 and Kane, 1974) that 20 to 25% of days, the diffusion component of the cosmic-ray neutron diurnal anisotropy is directed more than 30 degrees away from the ecliptic projection of the interplanetary magnetic field averaged over the same 24 hours. A number of explanations for this deviation are discussed and it is concluded that transverse gradient drifts due to gradients perpendicular to the ecliptic are likely, that diurnal variations in the diffusion component of the neutron anisotropy may affect results from single stations and that the 24 hour mean interplanetary magnetic field may not be the field appropriate to the streaming equation at neutron monitor energies.

  7. [White coat hypertension under outpatient conditions: indications for ambulatory monitoring of arterial pressure].

    PubMed

    Calderón Montero, A; Palma Gámiz, J L

    1997-01-01

    Ambulatory blood pressure monitoring (ABPM) is to be considered an excellent diagnostic tool, progressively used by the clinicians in their routine medical practice, in order to assess both medical diagnosis and antihypertensive treatment efficacy. ABPM permits to distinguish with a high level of accuracy the true hypertensives, from the false hypertensives or from subjects with isolated clinical hypertension, the old so-called "white coat hypertension". Prognostic implications of hypertension and target organ involvement can be assessed more accurately with ABPM than with basal blood pressure measurement. ABPM also permits an excellent approach to 24-hour blood pressure load, establishing different categories of circadian curves. In the same way, the 24-hour monitoring observation period during a normal daily life, helps to identify the hot moments of circadian period, correlating them, with changes in blood pressure, and subsequently with cardiovascular events, particularly in the early morning hours, during the so-called circadian vulnerable period, in which a significant increase in both cardiovascular events and stroke are usually observed. Nevertheless, some limitations are still linked to ABPM systems and equipments; on the one hand, the lack of a cut-off point, to establish the limits of true normally, and on the other one; the today intermittent character of ABPM measurements, do not permit an exact assessment of 24-hour blood pressure profile, containing all the hemodynamic changes. Several ongoing studies, will bring in the near future the very necessary answers to all these interrogants.

  8. Electrocardiographic patch devices and contemporary wireless cardiac monitoring

    PubMed Central

    Fung, Erik; Järvelin, Marjo-Riitta; Doshi, Rahul N.; Shinbane, Jerold S.; Carlson, Steven K.; Grazette, Luanda P.; Chang, Philip M.; Sangha, Rajbir S.; Huikuri, Heikki V.; Peters, Nicholas S.

    2015-01-01

    Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG), Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable “on-body” ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks) is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery. PMID:26074823

  9. The Brugada syndrome. Outcome of one case.

    PubMed

    Maia, I G; Soares, M W; Boghossian, S H; Sá, R

    2000-05-01

    The Brugada syndrome is a rare condition, and due to its mutating manner of presentation it may be difficult to diagnose. We report one case and discuss the diagnostic aspects and the clinical outcome of one patient with characteristic findings of this syndrome. These findings are especially defined by J-ST elevation in the right leads of serial electrocardiographic records, wide oscillations of J points and ST segments during 24-hour Holter monitoring, and nocturnal sudden death. We stress the importance of the Holter monitor findings for diagnostic complementation. Through this method it is possible to establish a correlation between vigil activities and sleep and the variability of the degree of impairment in ventricular repolarization.

  10. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    PubMed Central

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  11. Ambulatory monitoring detects sorafenib-induced blood pressure elevations on the first day of treatment

    PubMed Central

    Maitland, Michael L.; Kasza, Kristen E.; Karrison, Theodore; Moshier, Kristin; Sit, Laura; Black, Henry R.; Undevia, Samir D.; Stadler, Walter M.; Elliott, William J.; Ratain, Mark J.

    2009-01-01

    Purpose Hypertension is a mechanism-based toxicity of sorafenib and other cancer therapeutics that inhibit the vascular endothelial growth factor (VEGF) signaling pathway (VSP). This prospective, single center, cohort study characterized ambulatory blood pressure (BP) monitoring (ABPM) as an early pharmacodynamic biomarker of VSP inhibition by sorafenib. Experimental Design Fifty-four normotensive advanced cancer patients underwent 24-hour ABPM prior to and between days 6 and 10 of sorafenib therapy. After BP changes were detected among the first cohort within 10 days, ABPM was performed during the first 24 hours of treatment for the second cohort. Results For the entire patient population the BP increase (mean systolic +10.8 mmHg [95% CI, 8.6 to 13.0], range −5.2 to +28.7 mmHg; mean diastolic +8.0 mmHg [95% CI, 6.3 to 9.7], range −4.4 to +27.1mmHg) was detected between days 6 and 10 (P <0.0001 for both) and plateaued thereafter. Variability in BP change did not associate with: age, body size, sex, self-reported race, baseline BP, or steady state sorafenib plasma concentrations. In the second cohort the BP elevation was detected during the first 24 hours (mean systolic +8.2 mmHg [95% CI, 5.0 to 11.3]; mean diastolic +6.5 mmHg [95% CI, 4.7 to 8.3] P <0.0001 for both). Conclusions ABPM detects the BP response to VSP inhibition by sorafenib during the first 24 hours of treatment. The magnitude of BP elevation is highly variable and unpredictable, but could be important in optimizing the therapeutic index of VSP inhibitor therapy. PMID:19773379

  12. Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Weidhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    2000-01-01

    BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, p<0.05) while plasma osmolality remained unchanged (NS). Pre-exercise Tre was elevated after HDT24 (36.71 degrees C +/-0.06 HDT1 vs. 36.93 degrees C+/-0.11 HDT24, p<0.05). The 70 min of exercise did not alter this relationship (p<0.05) with respective end exercise increases in Tre to 38.01 degrees C and 38.26 degrees C (degrees = 1.30 degrees C (HDT1) and 1.33 degrees C (HDT24)). While there were no pre-exercise differences in mean skin temperature (Tsk), a significant (p<0.05) time x treatment interaction occurred during exercise: after min 30 in HDT24 the Tsk leveled off at 31.1 degrees C, while it continued to increase reaching 31.5 degrees C at min 70 in HDT1. A similar response (NS) occurred in skin blood velocity. Neither local sweating rates nor changes in body weight during exercise of -1.63+/-0.24 kg (HDT1) or - 1.33+/-0.09 kg (HDT24) were different (NS) between experiments. CONCLUSION: While HDT24 resulted in elevated pre-exercise Tre, reduced PV, attenuation of Tsk and skin blood velocity during exercise, the absolute increase in exercise Tre was not altered. But if sweat rate and cutaneous vascular responses were similar at different core temperatures (unchanged thermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.

  13. Successful in vitro antigen-dependent activation of 24-hour-old peripheral blood lymphocytes.

    PubMed

    Owen, J A; Muirhead, K; Jensen, C; Jonak, Z L

    1996-03-28

    We describe a simple, rapid and reproducible in vitro culture system in which human peripheral blood lymphocytes (PBLs), donated 24 h prior to initiation of culture can be stimulated to produce antigen-specific antibodies. Peripheral blood lymphocytes purified by Ficoll-Hypaque centrifugation were passed over a G10 Sephadex column and then activated in vitro in the presence of 0.003% staphylococcus Cowan A, 2.8 x 10(-6) M indomethacin and appropriate concentrations of tetanus toxoid antigen. After the first 24 h in culture, a five-fold concentrated supernatant from an allogeneic mixed lymphocyte culture was added. The cell surface phenotypes of the PBLs were analyzed by flow cytometry at the initiation and termination of culture, in order to provide a comprehensive characterization of the cellular composition of a successful in vitro stimulation system. Our results clearly show that the majority of peripheral blood B cells can be induced to an activated stage (blast transformation) and interleukin 2 (IL-2) receptor expression, following very simple manipulations of the lymphoid population. Tetanus toxoid-specific antibody production can be readily generated in this cell population. In contrast, T cells were not activated to express IL-2 receptors and reach blast transformation, and did not show appreciable proliferation. Our system provides a population of B cells producing antibodies of desired specificity which could be utilized for the generation of human hybridomas or could serve as a donor population for antibody engineering via the combinatorial library approach. Careful light scattering and cell surface phenotypic analyses of the cells entering, proliferating and differentiating in these cultures enabled several novel observations to be made.

  14. Influence of mild cold on the components of 24 hour thermogenesis in rats.

    PubMed Central

    Brown, D; Livesey, G; Dauncey, M J

    1991-01-01

    1. The influence of two weeks' acclimation to either 28 degrees C (thermal neutrality) or 21 degrees C (mild cold) on 24 h heat production and motor activity has been investigated in male Wistar rats. Food intake was controlled and provided as a single meal of approximately 170 kJ per day. Mathematical modelling was used to relate metabolic rate to measured movement and time of day. 2. For animals at thermal neutrality it was clear that metabolic rate increased during periods of substantial measured movement and returned to baseline during periods of minimal activity. Total heat production could therefore be divided into two components: underlying and movement-induced thermogenesis. 3. At 21 degrees C, a more complex model was needed. During periods of substantial activity, the relation between metabolic rate and movement was similar to that at 28 degrees C and total heat production could be divided into the same two components of underlying and movement-induced thermogenesis. However, during periods of prolonged inactivity, a different model was required, which included a component of extra metabolic activity, termed supplementary thermogenesis. By fitting this model to data at 28 and 21 degrees C, it was possible to partition 24 h heat production into the three possible sources of underlying, movement-induced and supplementary thermogenesis. 4. Total 24 h heat production was approximately 25% higher for rats at 21 compared with 28 degrees C (P less than 0.01) and underlying thermogenesis was approximately 20% higher for those in the mild cold (P less than 0.01). Measured movement was significantly reduced in the mild cold (P less than 0.05) although it was energetically less efficient since there was no difference in movement-induced thermogenesis, which accounted for 18 and 15% of total heat production at 28 and 21 degrees C respectively. Supplementary thermogenesis was observed only in the mild cold and it accounted for approximately 6% of 24 h heat production, while the peak value accounted for 20% of total heat production. Circadian variations in thermogenesis were also different at 28 compared with 21 degrees C. Possible mechanisms accounting for the components of underlying thermogenesis and supplementary thermogenesis are discussed. PMID:1816371

  15. Food-anticipatory rhythms under 24-hour schedules of limited access to single macronutrients.

    PubMed

    Mistlberger, R E; Houpt, T A; Moore-Ede, M C

    1990-01-01

    Food-restricted rats anticipate a fixed daily mealtime by entrainment of a circadian timekeeping mechanism separate from that which generates daily light-entrainable activity rhythms. The entrainment pathways and rhythm-generating substrates for food-anticipatory rhythms are unknown. In this study, we attempted to define minimal food-related stimuli necessary or sufficient for food anticipation by employing schedules of restricted macronutrient availability, with or without free access to a complementary diet. Rats did not anticipate a daily meal of protein, carbohydrate, or fat, as measured by tilt-cage, running-wheel, or food-bin activity, when they had free access to other nutrients. However, rats did anticipate single-macronutrient meals when they were limited to only two, larger, complementary meals each day (protein-fat, protein-carbohydrate) providing a reduced total number of calories. Previous work has shown that caloric restriction per se is not a prerequisite for food anticipation. In combination with that study, the present results indicate that the size of a nutrient meal, in absolute terms or relative to total daily nutrient intake, is of pre-eminent importance in determining its value as a synchronizer of anticipatory rhythms. The results further suggest that physiological responses unique to the ingestion and absorption of any particular macronutrient are not necessary components of the entrainment pathway.

  16. The Effects of Rilmenidine and Perindopril on Arousal Blood Pressure during 24 Hour Recordings in SHR

    PubMed Central

    Lim, Kyungjoon; Jackson, Kristy L.; Burke, Sandra L.; Head, Geoffrey A.

    2016-01-01

    The surge in arterial pressure during arousal in the waking period is thought to be largely due to activation of the sympathetic nervous system. In this study we compared in SHR the effects of chronic administration of the centrally acting sympatholytic agent rilmenidine with an angiotensin converting enzyme inhibitor perindopril on the rate of rise and power of the surge in mean arterial pressure (MAP) that occurs with arousal associated with the onset of night. Recordings were made using radiotelemetry in 17 adult SHR before and after treatment with rilmenidine (2mg/kg/day), perindopril (1mg/kg/day) or vehicle in the drinking water for 2 weeks. Rilmenidine reduced MAP by 7.2 ± 1.7mmHg while perindopril reduced MAP by 19 ± 3mmHg. Double logistic curve fit analysis showed that the rate and power of increase in systolic pressure during the transition from light to dark was reduced by 50% and 65%, respectively, but had no effect on diastolic pressure. Rilmenidine also reduced blood pressure variability in the autonomic frequency in the active period as assessed by spectral analysis which is consistent with reduction in sympathetic nervous system activity. Perindopril had no effect on the rate or power of the arousal surge in either systolic or diastolic pressure. These results suggest that the arousal induced surge in blood pressure can largely be reduced by an antihypertensive agent that inhibits the sympathetic nervous system and that angiotensin converting enzyme inhibition, while effective in reducing blood pressure, does not alter the rate or power of the surge associated with arousal. PMID:28002478

  17. Formative research of a quick list for an automated self-administered 24-Hour dietary recall

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Twenty-four-hour dietary recalls are used to collect high-quality dietary data. Because they require highly trained interviewers, recalls are expensive and impractical for large-scale nutrition research, leading to the use of food frequency questionnaires. We are developing a computer-based, self-ad...

  18. Estimation of daily salt intake through a 24-hour urine collection in Pohang, Korea.

    PubMed

    Kim, Yong Chul; Koo, Ho Seok; Kim, Suhnggwon; Chin, Ho Jun

    2014-09-01

    There is an established relationship between a high salt diet and public health problems, especially hypertension and cardiovascular disease. We estimated daily salt intake in a group of adults and assessed its association with related variables in Pohang, Korea. We conducted a cross-sectional survey in 2013 with 242 adults. Urine was collected for 24 hr to estimate daily salt intake, and questionnaires about salt preference were administered. The mean daily salt intake was 9.9±4.6 g. There was no difference in salt intake between high systolic blood pressure (SBP) participants and normal SBP participants (10.5±4.7 g/d vs. 9.6±4.3 g/d, P=0.339), but high diastolic blood pressure (DBP) participants reported more salt intake than normal DBP participants (10.4±4.9 g/d vs. 9.7±4.1 g/d, P=0.049). Salt intake and body mass index demonstrated a positive correlation (P=0.001). A preference for Korean soup or stew was associated with high salt intake (P=0.038). Dietary salt intake in Korean adults is still higher than the recommendation from the World Health Organization. More efforts should be made to reduce the salt consumption of Korean adults.

  19. Estimating 24-hour urine sodium level with spot urine sodium and creatinine.

    PubMed

    Koo, Ho Seok; Kim, Yong Chul; Ahn, Shin Young; Oh, Se Won; Kim, Suhnggwon; Chin, Ho Jun; Park, Jung Hwan

    2014-09-01

    The 24-hr urine sodium excretion level was estimated based on the spot urine sodium, and the efficacy of the formula was validated to determine the status of low salt intake <100 mEq Na/day. The 24-hr urine samples were collected from 400 patients. The 24-hr urine creatinine level was estimated with the use of three formulas: a newly derived Korean equation (E24UCR_K), and Tanaka (E24UCR_T) and Cockcroft-Gault (E24UCR_CG) equations. The correlation coefficients between the estimated and measured 24-hr urine creatinine for these three equations were 0.863, 0.846, and 0.896, respectively (All P<0.001). After estimating the 24-hr urine sodium levels, the correlation coefficients between the estimated and measured 24-hr urine sodium levels were 0.466, 0.490, and 0.516, respectively (All P<0.001). The sensitivity of three formulas to estimate the measured 24-hr urine sodium≥100 mEq/day using the estimated amount≥100 mEq/day was 84.3%, 87.6%, and 84.8%, respectively. In conclusion, the three equations used to estimate the 24-hr urine sodium content were useful to determine the status of low salt intake.

  20. Specific Antivenom Ability in Neutralizing Hepatic and Renal Changes 24 Hours after Latrodectus dahli Envenomation

    PubMed Central

    Valikhanfard-Zanjani, Elham; Zare-Mirakabadi, Abbas; Oryan, Shahrbanoo; Goodarzi, Hamid Reza; Rajabi, Mahdise

    2016-01-01

    Background: Latrodectism, a syndrome caused by Latrodectus genus, is one of the clinical problems that occur predominantly in north east of Iran. Nowadays antivenom therapy has become the most useful treatment for animal bites; however there is still a controversy about route and time of antivenom administration in spider bite. The aim of the present study was to determine the efficacy of specific antivenom in neutralizing hepatic and renal symptoms 24 h after Latrodectus dahli envenomation. Methods: We selected a group of male New Zealand white rabbits, weighing 2±0.3 kg. The L. dahli venom (0.5 mg/kg) was injected subcutaneously. Specific antivenom (2.5 ml, I.V) was injected 24 h following venom injection. Blood sampling was performed before and 24 h after venom injection, as well within 24, 48 and 72 h after antivenom administration. Serum levels of (aspartate amino transferase (AST) alanine amino transferase (ALT), alkaline phosphatase (ALP), urea, bilirubin, creatinine and albumin were determined in all the sam. Results: Latrodectus dahli venom caused significant increase (P< 0.05) in all foresaid serum parameters. Antivenom reversed the AST, ALP, creatinine, urea and bilirubin to normal levels, but failed about ALT level, also non-significant decrease was observed in albumin levels. Conclusion: Antivenom administration 24 h after venom injection can greatly reverse symptoms caused by venom. Future studies in human beings should be conducted to assess the protection against the specific-Latrodectus anti-venom. PMID:27308281

  1. 24 Hours in a Day: A Listening Update to the Time Studies

    ERIC Educational Resources Information Center

    Janusik, Laura A.; Wolvin, Andrew D.

    2009-01-01

    Time is an important communication variable that has been impacted by new technology and changed the way people communicate. This study of communication time use by college students provides an update to earlier studies by factoring in computer and telephone use--media that have forced a multitasking approach to communication. Undergraduate…

  2. Albumin infusion in humans does not model exercise induced hypervolaemia after 24 hours

    NASA Technical Reports Server (NTRS)

    Haskell, A.; Gillen, C. M.; Mack, G. W.; Nadel, E. R.

    1998-01-01

    We rapidly infused 234 +/- 3 mL of 5% human serum albumin in eight men while measuring haematocrit, haemoglobin concentration, plasma volume (PV), albumin concentration, total protein concentration, osmolality, sodium concentration, renin activity, aldosterone concentration, and atrial natriuretic peptide concentration to test the hypotheses that plasma volume expansion and plasma albumin content expansion will not persist for 24 h. Plasma volume and albumin content were expanded for the first 6 h after infusion (44.3 +/- 1.9-47.2 +/- 2.0 mL kg-1 and 1.9 +/- 0.1-2.1 +/- 0.1 g kg-1 at pre-infusion and 1 h, respectively, P < 0.05), but by 24 h plasma volume and albumin content decreased significantly from 1 h post-infusion and were not different from pre-infusion (44.8 +/- 1.9 mL kg-1 and 1.9 +/- 0.1 g kg-1, respectively). Plasma aldosterone concentration showed a significant effect of time over the 24 h after infusion (P < 0.05), and showed a trend to decrease at 2 h after infusion (167.6 +/- 32.5(-1) 06.2 +/- 13.4 pg mL-1, P = 0.07). These data demonstrate that a 6.8% expansion of plasma volume and 10.5% expansion of plasma albumin content by infusion does not remain in the vascular space for 24 h and suggest a redistribution occurs between the intravascular space and interstitial fluid space.

  3. Case Study: Psychiatric Misdiagnosis of Non-24-Hours Sleep-Wake Schedule Disorder Resolved by Melatonin

    ERIC Educational Resources Information Center

    Dagan, Yaron; Ayalon, Liat

    2005-01-01

    This case study describes a 14-year-old male suffering from significant academic and personal difficulties, who has been diagnosed with depression, schizotypal personality disorder, and learning disabilities. Because of excessive sleepiness, assessment for a potential sleep disorder was performed. An overnight polysomnographic study revealed no…

  4. 24-hour pattern of work-related injury risk of French firemen: nocturnal peak time.

    PubMed

    Riedel, Marc; Berrez, Stéphane; Pelisse, Didier; Brousse, Eric; Forget, Coralie; Marlot, Michel; Smolensky, Michael H; Touitou, Yvan; Reinberg, Alain

    2011-10-01

    The first aim of the study was to assess clock-time patterning of work-related injuries (WRIs) of firemen (FM) of Saône et Loire-71 (France) during the 4-yr span of 1 January 2004 to 31 December 2007. FM of this service are legally required to log every WRI and seek its evaluation by the medical service, whether the WRI was the result of worksite duties or exercise/sport activities at the station. WRI was defined specifically as a (nonexercise, nonsport, and nonemotional/stress) work-associated trauma, verified both by log book and medical records. For the corresponding years, the 24-h pattern of emergency calls (Calls) plus road traffic (Traffic) on the main roads of the service area was also assessed. Relative risk (R) of WRI was calculated as the quantity of WRIs/h divided by the quantity of Call responses/h × 1000, which takes into account the number of at-risk FM/unit time, since each dispatched emergency vehicle is staffed with 4 FM. Comparably trained regular (RFM) and volunteer (VFM) FM experienced a total of 187 WRIs. The 24-h WRI curve patterns of RFM and VFM were correlated (r = 0.4, p < .05), with no histogram difference (p > .05). Analysis of variance (ANOVA) validated comparable clock-time patterns in WRIs of RFM and VFM each year and each season (all p < .0001). Thus, time series of the RFM and VFM were pooled, revealing a statistical significant 24-h variation in WRIs (ANOVA, p > .0006; Cosinor analysis, p < .0001), with peak at 16:00 h and trough at 04:00 h. The 24-h pattern in Traffic, which mirrors that of human activity, with peak ∼18:00 h and trough ∼03:00 h, was also verified (ANOVA, p < .0001; Cosinor, p < .0001). Calls (n = 112,059) resulting in FM responses also exhibited statistically significant 24-h variation, with peak at ∼20:00 h and trough at ∼06:00 h. The 24-h pattern of R showed a nocturnal peak at 02:00 h (R = 2.87 ± 0.46; mean ± SEM) and diurnal trough 14:00 h (R = 1.30 ± 0.05) (t test, p < .02); clock-time-related changes in R were further validated by ANOVA (p = .0001) and Cosinor (p < .0001), with acrophase (peak time, Ø) of 02:43 h ± 68 min (SD). The second aim of the study was to evaluate the relationship between the 24-h patterns of WRIs and lag-time (LT) response (used as a measure of work performance) of FM of the same service to urgent medical calls for out-of-hospital cardiac arrests. Highest R of WRI at 02:00 h corresponded closely to longest LT (raw data at ∼02:00 h and Cosinor derived Ø of 02.54 h ± 71 min [SD]), thereby supporting the hypothesis of a common mechanism underlying the two 24-h profiles. A third aim was to determine the relevance of a new concept in work safety, "chronoprevention," for future FM training programs.

  5. Cardiorespiratory Assessment of 24-Hour Crash-Diet Effects on Altitude, +Gz, ad Fatigue Tolerances,

    DTIC Science & Technology

    1981-02-01

    Physiological measurements were recorded for 10 min at GL, after which the chamber pressure was reduced over a 10 min period to an altitude equivalent of...3,810 m. At altitude, four separate math tests were alternated with 10-min periods of resting physiological measurements as indicated in Table II...on this type of function. DISCUSSION In the nonfasting control condition, statistically significant physiological displacements (Tables IV-X) were

  6. Sex difference in the near-24-hour intrinsic period of the human circadian timing system

    PubMed Central

    Duffy, Jeanne F.; Cain, Sean W.; Chang, Anne-Marie; Phillips, Andrew J. K.; Münch, Mirjam Y.; Gronfier, Claude; Wyatt, James K.; Dijk, Derk-Jan; Czeisler, Charles A.

    2011-01-01

    The circadian rhythms of melatonin and body temperature are set to an earlier hour in women than in men, even when the women and men maintain nearly identical and consistent bedtimes and wake times. Moreover, women tend to wake up earlier than men and exhibit a greater preference for morning activities than men. Although the neurobiological mechanism underlying this sex difference in circadian alignment is unknown, multiple studies in nonhuman animals have demonstrated a sex difference in circadian period that could account for such a difference in circadian alignment between women and men. Whether a sex difference in intrinsic circadian period in humans underlies the difference in circadian alignment between men and women is unknown. We analyzed precise estimates of intrinsic circadian period collected from 157 individuals (52 women, 105 men; aged 18–74 y) studied in a month-long inpatient protocol designed to minimize confounding influences on circadian period estimation. Overall, the average intrinsic period of the melatonin and temperature rhythms in this population was very close to 24 h [24.15 ± 0.2 h (24 h 9 min ± 12 min)]. We further found that the intrinsic circadian period was significantly shorter in women [24.09 ± 0.2 h (24 h 5 min ± 12 min)] than in men [24.19 ± 0.2 h (24 h 11 min ± 12 min); P < 0.01] and that a significantly greater proportion of women have intrinsic circadian periods shorter than 24.0 h (35% vs. 14%; P < 0.01). The shorter average intrinsic circadian period observed in women may have implications for understanding sex differences in habitual sleep duration and insomnia prevalence. PMID:21536890

  7. Effect of 16 and 24 hours daily radiation (light) on lettuce growth

    NASA Technical Reports Server (NTRS)

    Koontz, H. V.; Prince, R. P.; Knott, W. M. (Principal Investigator)

    1986-01-01

    A 50% increase in total radiation by extending the photoperiod from 16 to 24 hr doubled the weight of all cultivars of loose-leaf lettuce (Lactuca sativa L.) 'Grand Rapids Forcing', 'Waldmanns Green', 'Salad Bowl', and 'RubyConn', but not a Butterhead cultivar, 'Salina'. When total daily radiation (moles of photons) was the same, plants under continuous radiation weighed 30% to 50% more than plants under a 16 hr photoperiod. By using continuous radiation on loose-leaf lettuce, fewer lamp fixtures were required and yield was increased.

  8. Mothers' Maximum Drinks Ever Consumed in 24 Hours Predicts Mental Health Problems in Adolescent Offspring

    ERIC Educational Resources Information Center

    Malone, Stephen M.; McGue, Matt; Iacono, William G.

    2010-01-01

    Background: The maximum number of alcoholic drinks consumed in a single 24-hr period is an alcoholism-related phenotype with both face and empirical validity. It has been associated with severity of withdrawal symptoms and sensitivity to alcohol, genes implicated in alcohol metabolism, and amplitude of a measure of brain activity associated with…

  9. 24 Hours in the Children's Section: An Observational Study at the Public Library

    ERIC Educational Resources Information Center

    Becker, Katherine

    2012-01-01

    The purpose of this study was to explore patronage and usage of the children's section of a public library. Patrons of the children's section of a public library in a small Northern Arizona city were observed for a total of 24 h over 12 sessions. Analytic induction was used to formulate categories based on field notes made during these…

  10. Enhanced depth OCT imaging of the lamina cribrosa for 24 hours

    PubMed Central

    Naranjo-Bonilla, Pedro; Giménez-Gómez, Rafael; Ríos-Jiménez, David; Varas-Fabra, María Luísa; Muñoz-Villanueva, María del Carmen; García-Catalán, Rocío; Font-Ugalde, Pilar; Poblador-Fernández, María Soledad; Lancho-Alonso, José Luís; Gallardo-Galera, José María

    2017-01-01

    The lamina cribrosa thickness (LCT) could be affected by dynamic changes in its structure. Using Spectral-domain-optical coherence tomography (SD-OCT), we have studied the behaviour of the laminar region in 14 young subjects over 24h. Significant changes in LCT were observed, depending on the time at which the measurement was taken, with the maximum thickness being observed at 7.30 p.m., and the minimum at 7.30 a.m. This finding could suggests a circadian pattern in the LCT thickness in healthy subjects, which could have implications for the classification, diagnosis and prognosis of both normal and glaucomatous subjects. PMID:28251093

  11. Moderate alcohol consumption and 24-hour urinary levels of melatonin in postmenopausal women

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Low overnight urinary melatonin metabolite concentrations have been associated with increased risk for breast cancer among postmenopausal women. The Postmenopausal Women's Alcohol Study was a controlled feeding study to test the effects of low to moderate alcohol intake on potential risk factors for...

  12. Design of solar thermal dryers for 24-hour food drying processes (abstract)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Solar drying is a ubiquitous method that has been adopted for many years as a food preservation method. Most of the published articles in the literature provide insight on the performance of solar dryers in service but little information on the dryer construction material selection process or mater...

  13. 24-Hour Glucose Profiles on Diets Varying in Protein Content and Glycemic Index

    PubMed Central

    van Baak, Marleen A.

    2014-01-01

    Evidence is increasing that the postprandial state is an important factor contributing to the risk of chronic diseases. Not only mean glycemia, but also glycemic variability has been implicated in this effect. In this exploratory study, we measured 24-h glucose profiles in 25 overweight participants in a long-term diet intervention study (DIOGENES study on Diet, Obesity and Genes), which had been randomized to four different diet groups consuming diets varying in protein content and glycemic index. In addition, we compared 24-h glucose profiles in a more controlled fashion, where nine other subjects followed in random order the same four diets differing in carbohydrate content by 10 energy% and glycemic index by 20 units during three days. Meals were provided in the lab and had to be eaten at fixed times during the day. No differences in mean glucose concentration or glucose variability (SD) were found between diet groups in the DIOGENES study. In the more controlled lab study, mean 24-h glucose concentrations were also not different. Glucose variability (SD and CONGA1), however, was lower on the diet combining a lower carbohydrate content and GI compared to the diet combining a higher carbohydrate content and GI. These data suggest that diets with moderate differences in carbohydrate content and GI do not affect mean 24-h or daytime glucose concentrations, but may result in differences in the variability of the glucose level in healthy normal weight and overweight individuals. PMID:25093276

  14. After 24-hour scrub, the Boeing Delta II rocket carrying Stardust launches on time

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Into a pristine blue sky, the Boeing Delta II rocket carrying the Stardust spacecraft leaves clouds of exhaust behind as it lifts off at 4:04:15 p.m. EST from Launch Pad 17-A, Cape Canaveral Air Station. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  15. Stability, precision, and near-24-hour period of the human circadian pacemaker

    NASA Technical Reports Server (NTRS)

    Czeisler, C. A.; Duffy, J. F.; Shanahan, T. L.; Brown, E. N.; Mitchell, J. F.; Rimmer, D. W.; Ronda, J. M.; Silva, E. J.; Allan, J. S.; Emens, J. S.; Dijk, D. J.; Kronauer, R. E.

    1999-01-01

    Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.

  16. Radio telemetry documents 24-hour feeding activity of wintering lesser scaup

    USGS Publications Warehouse

    Custer, Christine M.; Custer, T.W.; Sparks, D.W.

    1996-01-01

    We used radio telemetry to record 198 h of feeding behavior of five Lesser Scaup (Aythya affinis) on the Indiana Harbor Canal in northwestern Indiana during January and February 1994. Lesser Scaup fed for short periods of time intermittently during each 24-h period. Lesser Scaup fed a total of 96 min during the day and 226 min during the night. They fed more between sunset and midnight (31.9% of the period, P = 0.003) than between sunrise and noon (11.6%) or noon and sunset (19.5%); time spent feeding between midnight and sunrise (26.3%) did not differ from other times of day. Mean dive duration (22.9 ± 0.64 sec) did not vary by time of day (P = 0.186-0.744). These results are the first 24-h feeding activity reported for individually marked Lesser Scaup.

  17. Continuous measurement of temperature in non-24 hour sleep-wake syndrome.

    PubMed

    Shibui, K; Okawa, M; Uchiyama, M; Ozaki, S; Kamei, Y; Hayakawa, T; Urata, J

    1998-04-01

    The onset of the low temperature (LT) zone which was defined as a period when the rectal temperature was below its daily mean is a convenient circadian phase marker. In this study, we document three cases of non-24 h sleep-wake syndrome in which identification of the LT zone as an evening circadian phase marker contributed to clinical judgments. We found that the LT zone was correlated well with dim light melatonin onset. Moreover, calculating the LT zone was useful in determining phase position in irregular sleep pattern and in determining the timing of bright light therapy.

  18. Fluid and electrolyte balance during 24-hour fluid and/or energy restriction.

    PubMed

    James, Lewis J; Shirreffs, Susan M

    2013-12-01

    Weight categorized athletes use a variety of techniques to induce rapid weight loss (RWL) in the days leading up to weigh in. This study examined the fluid and electrolyte balance responses to 24-hr fluid restriction (FR), energy restriction (ER) and fluid and energy restriction (F+ER) compared with a control trial (C), which are commonly used techniques to induce RWL in weight category sports. Twelve subjects (six male, six female) received adequate energy and water (C) intake, adequate energy and restricted water (~10% of C; FR) intake, restricted energy (~25% of C) and adequate water (ER) intake or restricted energy (~25% of C) and restricted (~10% of C) water intake (F+ER) in a randomized counterbalanced order. Subjects visited the laboratory at 0 hr, 12 hr, and 24 hr for blood and urine sample collection. Total body mass loss was 0.33% (C), 1.88% (FR), 1.97% (ER), and 2.44% (F+ER). Plasma volume was reduced at 24 hr during FR, ER, and F+ER, while serum osmolality was increased at 24 hr for FR and F+ER and was greater at 24 hr for FR compared with all other trials. Negative balances of sodium, potassium, and chloride developed during ER and F+ER but not during C and FR. These results demonstrate that 24 hr fluid and/ or energy restriction significantly reduces body mass and plasma volume, but has a disparate effect on serum osmolality, resulting in hypertonic hypohydration during FR and isotonic hypohydration during ER. These findings might be explained by the difference in electrolyte balance between the trials.

  19. Gender differences in the relationship between resting heart rate variability and 24-hour blood pressure variability.

    PubMed

    Thayer, Julian F; Sollers, John J; Friedman, Bruce H; Koenig, Julian

    2016-01-01

    The study explored the relationship between time- and frequency-domain indices of cardiac autonomic control and 24 h blood pressure variability (BPV) in a sample of healthy men and women. Vagally mediated cardiac control was inversely related to 24 h BPV, and measures of cardiac autonomic control were better predictors of systolic BPV in men and better predictors of diastolic BPV in women. These findings may help researchers to understand the disparity in cardiovascular disease morbidity and mortality between men and women.

  20. Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

    NASA Technical Reports Server (NTRS)

    Ertl, A. C.; Dearborn, A. S.; Weldhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    1998-01-01

    Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

  1. Physiological biochemical, and performance responses to a 24-hour crash diet.

    PubMed

    Higgins, E A; Mertens, H W; McKenzie, J M; Funkhouser, G E

    1982-03-01

    Twelve overweight male subjects were evaluated on both a normal diet and a 24-h crash diet. During approximately 2 1/4-h complex performance tests subjects breathed an O2/N2 mixture equivalent to 3810 m. (12,500 ft). There were no significant findings due to diet for heart rate, blood pressure, serum electrolytes, subjective fatigue and urinary excretion of K+, epinephrine and norepinephrine. body temperatures were lower (p less than 0.05) for the crash diet than for the normal diet. Serum glucose levels increased during the normal diet and decreased during the crash diet. Hematocrit increased more for the crash diet (p less than 0.05) than for the normal diet. Urinary excretion of 17-ketogenic steroids was less (p less than 0.001) during sleep for the crash diet than for the normal diet. Complex performance showed no significant differences when subjects were tested under low workloads. Performance was enhanced during the crash diet when subjects were tested under the medium and high workload conditions.

  2. Metformin induces cardioprotection against ischaemia/reperfusion injury in the rat heart 24 hours after administration.

    PubMed

    Solskov, Lasse; Løfgren, Bo; Kristiansen, Steen B; Jessen, Niels; Pold, Rasmus; Nielsen, Torsten T; Bøtker, Hans Erik; Schmitz, Ole; Lund, Sten

    2008-07-01

    The UK Prospective Diabetes Study demonstrated that the hypoglycaemic drug metformin is associated with a reduction in cardiovascular events in a group of obese type 2 diabetes patients. The energy sensing enzyme AMP-activated protein kinase (AMPK) has been indicated to play an important protective role in the ischaemic heart and is activated by metformin. The aim of this study was to determine whether a single dose of metformin protects the myocardium against experimentally induced ischaemia 24 hr after the administration, and furthermore to determine whether a single dose of metformin results in an acute increase in myocardial AMPK activity. Wistar rats were given either a single oral dose of metformin (250 mg/kg body weight), or a single oral dose of saline. After 24 hr, the hearts were Langendorff-perfused and subjected to 45 min. of coronary artery occlusion. Infarct size was determined by staining with triphenyltetrazoliumchloride (TTC) and Evans Blue and expressed as a percentage of the risk zone (IS/AAR %). Isoform specific AMPK activity was measured 2 hr after administration of metformin or saline. Infarct size was significantly reduced in the metformin treated (I/R: 19.9 +/- 3.9%versus 36.7 +/- 3.6%, P < 0.01, n = 8-14) compared to the control group. A single oral dose of metformin resulted in an approximately ~2-fold increase in AMPK-alpha2 activity 2 hr after administration (P < 0.015, n = 10). In conclusion, a single dose of metformin results in an acute increase in myocardial AMPK activity measured 2 hr after administration and induces a significant reduction in myocardial infarct size 24 hr after metformin administration. Increased AMPK activity may be an important signal mediator involved in the mechanisms behind the cardioprotective effects afforded by metformin.

  3. Esophageal perforation: diagnostic work-up and clinical decision-making in the first 24 hours

    PubMed Central

    2011-01-01

    Esophageal perforation is a rare and potentially life-threatening condition. Early clinical suspicion and imaging is important for case management to achieve a good outcome. However, recent studies continue to report high morbidity and mortality greater than 20% from esophageal perforation. At least half of the perforations are iatrogenic, mostly related to endoscopic instrumentation used in the upper gastrointestinal tract, while about a third are spontaneous perforations. Surgical treatment remains an important option for many patients, but a non-operative approach, with or without use of an endoscopic stent or placement of internal or external drains, should be considered when the clinical situation allows for a less invasive approach. The rarity of this emergency makes it difficult for a physician to obtain extensive individual clinical experience; it is also challenging to obtain firm scientific evidence that informs patient management and clinical decision-making. Improved attention to non-specific symptoms and signs and early diagnosis based on imaging may translate into better outcomes for this group of patients, many of whom are elderly with significant comorbidity. PMID:22035338

  4. Effects of chlorhexidine in self-etching adhesive: 24 hours results.

    PubMed

    Nishitani, Yoshihiro; Hosaka, Keiichi; Hoshika, Tomohiro; Yoshiyama, Masahiro; Pashley, David H

    2013-01-01

    It is known that chlorhexidine (CHX) does not inhibit micro-tensile bond strengths (MTBS) when it is used in etch-and-rinse adhesives. In that technique, CHX is applied to dentin as a primer after phosphoric acid-etching before bonding with Single Bond. It would be more convenient if it is possible to incorporate CHX into the adhesive. The purpose of this study was to compare the MTBS and the FT-IR percent conversion of an all-in-one self-etching adhesives contained varying concentration of CHX. Extracted human third molars were bonded with a control all-in-one adhesive or experimental versions containing 0.5, 1, 2 or 5% CHX. The MTBS and the percent conversion of experimental adhesives containing up to 1% CHX were not significantly CHX-free control adhesives. However, addition of 2 or especially 5% CHX experimental adhesives produced significant reductions in both the MTBS and the percent conversion.

  5. Metabolic effects of isoenergetic nutrient exchange over 24 hours in relation to obesity in women.

    PubMed

    Lean, M E; James, W P

    1988-01-01

    Twenty-four hour whole body indirect calorimetry has been used to study the effects of feeding, during a sedentary test day, isoenergetic diets which varied in fat (3 or 40 per cent of total energy) and carbohydrate (82 or 45 per cent) content. Three groups of women were studied: lean, obese and 'post-obese' after slimming. Energy expenditure was greater in absolute terms in the obese women. Twenty-four hour energy expenditure was lower by only 3-7 per cent when fasting compared to that when fed to achieve energy balance. There were no large differences in energy expenditure between the two diets or between the groups but the thermogenic effect of the high carbohydrate diet was significantly greater than that of the high fat diet (5.8 vs 3.5 per cent of energy expenditure: P less than 0.01). The post-obese tended to have lower energy expenditure per kg FFM than controls when fasting and when high-fat fed, but this pattern was not shown by the obese. Sleeping energy expenditure was particularly low in the post-obese group when high-fat fed. Dirunal variations in RQ appear to show more marked rise in morning RQ from the nocturnal minimum in the obese and post-obese, which might be evidence for an energy-saving mechanism through greater availability of stored dietary carbohydrate.

  6. Design of solar thermal dryers for 24-hour food drying processes

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Solar drying is a method that has been adopted for many years as a food preservation method. To this date, significant advancements have been made in this field with the adoption of a multitude of solar thermal dryer designs for single-layer and multi-layer drying of fruit and vegetables e.g. cabine...

  7. A Non-invasive 24 Hours Stabilization of Duodenal Ulcer Perforation by a Combination Regimen

    PubMed Central

    Zil-E-Ali, Ahsan; Bin Shafique, Muhammad; Ali, Hammad; Ghani, Usman

    2016-01-01

    Surgical repair of perforated gastroduodenal ulcer has been extensively practiced in emergency clinical situations. Non-invasive conservation treatment is regaining the attention towards management of such ulcers. We report the case of a 50-year-old male smoker who presented in the emergency unit with acute generalized abdominal pain and guarding in the epigastric and right upper quadrant region. He is a known regular user of over-the-counter nonsteroidal anti-inflammatory drugs (NSAIDS) for more than 10 years for his osteoarthiritis and myalgias. A differential diagnosis of gastritis and duodenal perforation was made owing to the symptoms and long usage of NSAIDs. He was managed with an intravenous proton pump inhibitor and intravenous antibiotics. This therapy lead to stabilization of the clinical symptoms as well as laboratory and imaging studies. PMID:28083452

  8. Effect of 16 and 24 hours daily radiation (light) on lettuce growth.

    PubMed

    Koontz, H V; Prince, R P

    1986-02-01

    A 50% increase in total radiation by extending the photoperiod from 16 to 24 hr doubled the weight of all cultivars of loose-leaf lettuce (Lactuca sativa L.) 'Grand Rapids Forcing', 'Waldmanns Green', 'Salad Bowl', and 'RubyConn', but not a Butterhead cultivar, 'Salina'. When total daily radiation (moles of photons) was the same, plants under continuous radiation weighed 30% to 50% more than plants under a 16 hr photoperiod. By using continuous radiation on loose-leaf lettuce, fewer lamp fixtures were required and yield was increased.

  9. Systems Chronobiology: Global Analysis of Gene Regulation in a 24-Hour Periodic World.

    PubMed

    Mermet, Jérôme; Yeung, Jake; Naef, Felix

    2017-03-01

    Mammals have evolved an internal timing system, the circadian clock, which synchronizes physiology and behavior to the daily light and dark cycles of the Earth. The master clock, located in the suprachiasmatic nucleus (SCN) of the brain, takes fluctuating light input from the retina and synchronizes other tissues to the same internal rhythm. The molecular clocks that drive these circadian rhythms are ticking in nearly all cells in the body. Efforts in systems chronobiology are now being directed at understanding, on a comprehensive scale, how the circadian clock controls different layers of gene regulation to provide robust timing cues at the cellular and tissue level. In this review, we introduce some basic concepts underlying periodicity of gene regulation, and then highlight recent genome-wide investigations on the propagation of rhythms across multiple regulatory layers in mammals, all the way from chromatin conformation to protein accumulation.

  10. Hypertrophic cardiomyopathy

    MedlinePlus

    ... thickness, problems with blood flow, or leaky heart valves ( mitral valve regurgitation ) may include: Echocardiography ECG 24-hour Holter ... You may need surgery to repair the heart's mitral valve if it is leaking. Watch this video about: ...

  11. Ligation of the left hepatic vein for dilated intrahepatic collaterals late after fontan operation.

    PubMed

    Park, Chun Soo; Park, Jeong-Jun; Park, In-Sook; Goo, Hyun Woo

    2014-07-01

    A 17-year-old male presented with two episodes of syncope, cyanosis, and exercise intolerance 13 years after the Fontan operation. Echocardiography and magnetic resonance imaging showed dilated intrahepatic collaterals, which drained into the atrium through the left hepatic vein, and 24-hour Holter monitoring revealed sinus node dysfunction. We performed ligation of the left hepatic vein using intrahepatic collaterals as channels draining hepatic venous blood into the Fontan pathway, and implanted an epicardial dual chamber pacemaker. At one-year follow-up, the patient remained asymptomatic and his cardiac performance was much improved.

  12. Authenticated Tracking and Monitoring System (ATMS) tracking shipments from an Australian uranium mine

    SciTech Connect

    Schoeneman, J.L.; Sorokowski, D.

    1997-10-01

    The Authenticated Tracking and Monitoring System (ATMS) answers the need for global monitoring of the status and location of sensitive items on a worldwide basis, 24 hours a day. The ATMS concept uses wireless sensor packs to monitor the status of the items and environmental conditions, to collect a variety of sensor event data, and to transmit the data through the INMARSAT satellite communication system, which then sends that data to appropriate ground stations for tracking and monitoring. Authentication and encryption algorithms are used throughout the system to secure the data during communication activities. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements.

  13. Recognizing the Challenges of Ambient Air Monitoring in the Persian Gulf

    NASA Astrophysics Data System (ADS)

    Meade, T. G.; Nicodemus, M. A.; Howard, J. M.

    2011-12-01

    In an effort to better estimate environmental exposure, the U.S. Army Public Health Command has been operating an ambient air monitoring station in Shuaiba Port, Kuwait since 2002. The focus has primarily been on monitoring criteria pollutants at a busy sea port where local industry (oil refineries, cement plant, petrochemical production, etc.) heavily impacts air quality. To compound the issues associated with day to day monitoring at a busy sea port, the region often experiences sand storms and temperatures up to 60°C. Average daily particulate matter concentrations at Shuaiba Port are an order of magnitude higher than similar industrial areas in the U.S. On days when sand storms occur ambient PM concentrations can be two or three orders higher than average daily U.S. concentrations. For example, 24-hour average PM10 concentrations from 2004-2010 for the month of June were 395 μg/m3. During sand storms, 24-hour average concentrations can reach as high as 4,000 μg/m3. This poster presents 2004-2010 particulate matter data collected at Shuaiba Port, Kuwait and outlines logistical and environmental challenges associated with air monitoring in the region.

  14. Clinical validation of LTMS-S: A wearable system for vital signs monitoring.

    PubMed

    Chételat, Olivier; Ferrario, Damien; Proença, Martin; Porchet, Jacques-André; Falhi, Abdessamad; Grossenbacher, Olivier; Delgado-Gonzalo, Ricard; Della Ricca, Nicolas; Sartori, Claudio

    2015-01-01

    LTMS-S is a new wearable system for the monitoring of several physiological signals--including a two-lead electrocardiogram (ECG)--and parameters, such as the heart rate, the breathing rate, the peripheral oxygen saturation (SpO2), the core body temperature (CBT), and the physical activity. All signals are measured using only three sensors embedded within a vest. The sensors are standalone with their own rechargeable battery, memory, wireless communication and with an autonomy exceeding 24 hours. This paper presents the results of the clinical validation of the LTMS-S system.

  15. Air monitoring of volatile organic compounds at relevant receptors during hydraulic fracturing operations in Washington County, Pennsylvania.

    PubMed

    Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M

    2016-07-01

    A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.

  16. Remote Physical Activity Monitoring in Neurological Disease: A Systematic Review

    PubMed Central

    Block, Valerie A. J.; Pitsch, Erica; Tahir, Peggy; Cree, Bruce A. C.; Allen, Diane D.; Gelfand, Jeffrey M.

    2016-01-01

    Objective To perform a systematic review of studies using remote physical activity monitoring in neurological diseases, highlighting advances and determining gaps. Methods Studies were systematically identified in PubMed/MEDLINE, CINAHL and SCOPUS from January 2004 to December 2014 that monitored physical activity for ≥24 hours in adults with neurological diseases. Studies that measured only involuntary motor activity (tremor, seizures), energy expenditure or sleep were excluded. Feasibility, findings, and protocols were examined. Results 137 studies met inclusion criteria in multiple sclerosis (MS) (61 studies); stroke (41); Parkinson's Disease (PD) (20); dementia (11); traumatic brain injury (2) and ataxia (1). Physical activity levels measured by remote monitoring are consistently low in people with MS, stroke and dementia, and patterns of physical activity are altered in PD. In MS, decreased ambulatory activity assessed via remote monitoring is associated with greater disability and lower quality of life. In stroke, remote measures of upper limb function and ambulation are associated with functional recovery following rehabilitation and goal-directed interventions. In PD, remote monitoring may help to predict falls. In dementia, remote physical activity measures correlate with disease severity and can detect wandering. Conclusions These studies show that remote physical activity monitoring is feasible in neurological diseases, including in people with moderate to severe neurological disability. Remote monitoring can be a psychometrically sound and responsive way to assess physical activity in neurological disease. Further research is needed to ensure these tools provide meaningful information in the context of specific neurological disorders and patterns of neurological disability. PMID:27124611

  17. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study.

    PubMed

    Gargiulo, Gaetano D; O'Loughlin, Aiden; Breen, Paul P

    2015-02-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need.In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial.

  18. High Resolution 12-lead Electrocardiograms of On-Duty Professional Firefighters: A Pilot Feasibility Study

    PubMed Central

    Carey, Mary G.; Thevenin, Bernard J.-M.

    2010-01-01

    Background Cardiovascular deaths among on-duty firefighters are high; double that of police officers and quadruple that of first responders. The aim of this pilot study was to establish the feasibility of obtaining high resolutions ECGs of on-duty firefighters useful for detecting ECG predictors for cardiac events. Methods Twenty-eight professional firefighters (age, 46 ± 6 years) wore a 12-lead ECG Holter for 24 hours (16 hours while on-duty and 8 hours post-duty). All activities including fire and medical calls were monitored. Results On average the recordings were 92% analyzable. All were in sinus with a heart rate of 80 ±11bpm (35–188 range). The average rr50 over the 24-hour Holter study was 6.2 ±6% (range: 1–23%) and rms-SD was 81 ± 55 (range: 24–209). Using the QRS/Tsimple formula, the average spatial QRS-T angle was 104 ±17 degrees (range 78–132 degrees). Nonsustained ventricular tachycardia occurred irrespectively of activity or time of day in three (11%) firefighters, which was significantly higher than in comparable normal populations (p<0.05). Conclusions This preliminary work demonstrates that it is feasible to obtain high resolution ECGs during firefighting activities and further points to the high prevalence of arrhythmias among firefighters. The strategy of continuous field monitoring of firefighters could provide new insight into the association between their specific professional lifestyle and high cardiac risks. PMID:21206348

  19. Heart-rate monitoring by air pressure and causal analysis

    NASA Astrophysics Data System (ADS)

    Tsuchiya, Naoki; Nakajima, Hiroshi; Hata, Yutaka

    2011-06-01

    Among lots of vital signals, heart-rate (HR) is an important index for diagnose human's health condition. For instance, HR provides an early stage of cardiac disease, autonomic nerve behavior, and so forth. However, currently, HR is measured only in medical checkups and clinical diagnosis during the rested state by using electrocardiograph (ECG). Thus, some serious cardiac events in daily life could be lost. Therefore, a continuous HR monitoring during 24 hours is desired. Considering the use in daily life, the monitoring should be noninvasive and low intrusive. Thus, in this paper, an HR monitoring in sleep by using air pressure sensors is proposed. The HR monitoring is realized by employing the causal analysis among air pressure and HR. The causality is described by employing fuzzy logic. According to the experiment on 7 males at age 22-25 (23 on average), the correlation coefficient against ECG is 0.73-0.97 (0.85 on average). In addition, the cause-effect structure for HR monitoring is arranged by employing causal decomposition, and the arranged causality is applied to HR monitoring in a setting posture. According to the additional experiment on 6 males, the correlation coefficient is 0.66-0.86 (0.76 on average). Therefore, the proposed method is suggested to have enough accuracy and robustness for some daily use cases.

  20. Microseismic monitoring of the Chaveroo oil field, New Mexico

    SciTech Connect

    Rutledge, J.T.; Albright, J.N.; Fairbanks, T.D.; Murphy, M.B.; Roberts, P.M.

    1990-01-01

    Induced microseismicity was monitored in the Chaveroo oil field in southeastern New Mexico during a pressurized stimulation of a well being prepared as an injector for a waterflood operation. In addition, the microseismicity was monitored for 5 weeks following the stimulation while the area was under normal waterflood production. Little seismicity was detected during the 5.5 hour stimulation in which three thousand barrels of water were injected into the reservoir at pressures ranging from 96 to 257 bars in excess of hydrostatic pressure. Intermittent monitoring over the 5-week period indicated detectable seismicity occurred during waterflood production. Monitoring during the 5 weeks, however, was not complete enough to draw general conclusions on temporal variations of observed microseismicity. Seventy-three good quality events recorded over a cumulative 24 hours of intermittent monitoring were located using the hodogram technique. Events were detected at distances up to 1700 m from the monitor well but most occurred within 900 m. The map of microearthquake locations indicated that events occurred in the vicinity of producing wells and away from injection wells. The first half of the sequence of mappable events occurred along linear trends, but the pattern became more scattered during the later half of the sequence. The lack of seismicity during the pressurized injection and the increased seismicity levels occurring away from injection wells during waterflood production, suggest seismicity is not induced by Mohr-Coulomb failure. 6 refs., 6 figs.

  1. Comparative study of T-amplitude features for fitness monitoring using the ePatch® ECG recorder.

    PubMed

    Thorpe, Julia Rosemary; Saida, Trine; Mehlsen, Jesper; Mehlsen, Anne-Birgitte; Langberg, Henning; Hoppe, Karsten; Sorensen, Helge B D

    2014-01-01

    This study investigates ECG features, focusing on T-wave amplitude, from a wearable ECG device as a potential method for fitness monitoring in exercise rehabilitation. An automatic T-peak detection algorithm is presented that uses local baseline detection to overcome baseline drift without the need for preprocessing, and offers adequate performance on data recorded in noisy environments. The algorithm is applied to 24 hour data recordings from two subject groups with different physical activity histories. Results indicate that, while mean heart rate (HR) differs most significantly between the groups, T-amplitude features could be useful depending on the disparities in fitness level, and require further investigation on an individual basis.

  2. Dynamic magnetic resonance monitoring of interstitial laser photocoagulation of hepatic metastases from a colorectal tumor

    NASA Astrophysics Data System (ADS)

    Roberts, Hugh R.; Paley, Martyn; Buonaccorsi, Giovanni A.; Clemence, Matthew; Friedman, Emma P.; Allen, Clare; Hall-Craggs, Margret A.; Lees, William R.; Bown, Stephen G.

    1994-12-01

    Interstitial laser photocoagulation (ILP) is becoming an established treatment for hepatic metastases. Per-procedural ultrasound does not accurately define the tissue coagulated and dynamic computed tomography, while an accurate form of assessment, must be delayed until 24 hours after therapy; it too is, therefore, no use for per-procedural confirmation of total tumor ablation. By virtue of its good contrast, spatial and temporal resolution and the fact that T1 weighted images are temperature sensitive magnetic resonance imaging (MRI) is, theoretically, applicable to the per-procedural guidance of ILP. Our ex vivo porcine, and in vivo rat liver experiments showed good imaging-pathological agreement. We have treated with ILP two patients suffering from hepatic metastases using MRI guidance. Four to eight 400 micrometers optical fibers were passed through the lesion down Teflon sheaths under local anaesthetic and intravenous sedation using ultrasound guidance. Sets of 400 second laser burns at 1.5 - 2.0 W per fiber were then performed, with a 1 cm fiber withdrawal between each set, until the entire tumor had been coagulated. Therapy was monitored with dynamic MRI using a T1 weighted FLASH sequence. MRI showed an enlarging bright rimmed low signal area which correlated with the region of devascularization seen on enhanced helical computed tomography at 24 hours. MRI can monitor ILP of hepatic metastases and confirm tumor ablation at the time of treatment.

  3. Disease management in the young diabetic patient: glucose monitoring, coping skills, and treatment strategies.

    PubMed

    Weinzimer, Stuart A; Doyle, Elizabeth A; Tamborlane, William V

    2005-06-01

    Type 1 diabetes mellitus was thought to be the prevalent type of diabetes in children and adolescents; however, increasing numbers of juvenile patients appear to have type 2 diabetes. Management of all diabetes in young patients should include regular assessment, careful monitoring for glycemic control and the presence of hypoglycemia, and educational training on disease management. Hypoglycemic episodes, especially nocturnal events, are frequent in the young diabetic patient. Improvements in glycemic control and nocturnal hypoglycemia have been observed with continuous subcutaneous insulin infusion and insulin glargine. A continuous glucose-monitoring system can provide important insight into 24-hour glycemic control. Overall, careful management, monitoring, and education can improve glycemic control and yield positive treatment outcomes in the child or adolescent with diabetes.

  4. Development of the Arctic radionuclide monitoring station

    SciTech Connect

    King, S.E.; Phillips, G.W.; Aakenes, U.R.

    1996-12-31

    In recent years, the world has learned about the dumping of nuclear reactors and other waste into the Arctic seas by the former Soviet Union. Most of the information on the present levels of radioactivity in the region has been obtained by oceanographic expeditions conducted during the brief Arctic summers. Year-round monitoring of the movement of radio-activity during dynamic seasonal and episodic chances is hampered by the difficulties caused by sea ice, logistics and communication constraints associated with deployment and maintenance of monitoring equipment in this remote region. We have designed an autonomous station to measure the benthic gamma-ray emitting radioactivity for periods of at least one year. The station is capable of detecting a 30 Bq/m{sup 3} increase in the {sup 137}Cs activity in a 24 hour period. After a year-long deployment, the station releases its anchor and rises to the surface to transmit the accumulated spectra and oceanographic data via an Argos satellite link. The design and performance characteristics of the prototype station will be discussed.

  5. Real-time optoacoustic monitoring of stroke

    NASA Astrophysics Data System (ADS)

    Kneipp, Moritz; Turner, Jake; Hambauer, Sebastian; Krieg, Sandro M.; Lehmberg, Jens; Lindauer, Ute; Razansky, Daniel

    2014-03-01

    Characterizing disease progression and identifying possible therapeutic interventions in stroke is greatly aided by the use of longitudinal function imaging studies. In this study, we investigate the applicability of real-time multispectral optoacoustic tomography (MSOT) as a tool for non-invasive monitoring of the progression of stroke in the whole brain. The middle cerebral artery occlusion (MCAO) method was used to induce stroke. Mice were imaged under isoflurane anesthesia preoperatively and at several time points during and after the 60-minute occlusion. The animals were sacrificed after 24 hours and their excised brains frozen at -80°C for sectioning. The cryosection were stained using H&E staining to identify the ischemic lesion. Major vessels are readily identifiable in the whole mouse head in the in vivo optoacoustic scans. During ischemia, a reduction in cerebral blood volume is detectable in the cortex. Post ischemia, spectral unmixing of the optoacoustic signals shows an asymmetry of the deoxygenated hemoglobin in the hemisphere affected by MCAO. This hypoxic area was mainly located around the boundary of the ischemic lesion and was therefore identified as the ischemic penumbra. Non-invasive functional MSOT imaging is able to visualize the hypoxic penumbra in brains affected by stroke. Stopping the spread of the infarct area and revitalizing the penumbra is central in stroke research, this new imaging technique may therefore prove to be a valuable tool in the monitoring and developing new treatments.

  6. 10 CFR 34.47 - Personnel monitoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... dosimeter must be sent for processing within 24 hours. In addition, the individual may not resume work... (sounds) before using at the start of each shift; (2) Be set to give an alarm signal at a preset dose...

  7. Monitoring materials

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2002-01-01

    The apparatus and method provide techniques for effectively implementing alpha and/or beta and/or gamma monitoring of items or locations as desired. Indirect alpha monitoring by detecting ions generated by alpha emissions, in conjunction with beta and/or gamma monitoring is provided. The invention additionally provides for screening of items prior to alpha monitoring using beta and/or gamma monitoring, so as to ensure that the alpha monitoring apparatus is not contaminated by proceeding direct to alpha monitoring of a heavily contaminated item or location. The invention provides additional versatility in the emission forms which can be monitored, whilst maintaining accuracy and avoiding inadvertent contamination.

  8. How Is Long QT Syndrome Diagnosed?

    MedlinePlus

    ... a simple test that detects and records the heart's electrical activity. This test may show a long QT interval ... a Holter monitor . A Holter monitor records the heart's electrical activity for a full 24- or 48-hour period. ...

  9. Wearable and low-stress ambulatory blood pressure monitoring technology for hypertension diagnosis.

    PubMed

    Altintas, Ersin; Takoh, Kimiyasu; Ohno, Yuji; Abe, Katsumi; Akagawa, Takeshi; Ariyama, Tetsuri; Kubo, Masahiro; Tsuda, Kenichiro; Tochikubo, Osamu

    2015-01-01

    We propose a highly wearable, upper-arm type, oscillometric-based blood pressure monitoring technology with low-stress. The low-stress is realized by new developments in the hardware and software design. In the hardware design, conventional armband; cuff, is almost halved in volume thanks to a flexible plastic core and a liquid bag which enhances the fitness and pressure uniformity over the arm. Reduced air bag volume enables smaller motor pump size and battery leading to a thinner, more compact and more wearable unified device. In the software design, a new prediction algorithm enabled to apply less stress (and less pain) on arm of the patient. Proof-of-concept experiments on volunteers show a high accuracy on both technologies. This paper mainly introduces hardware developments. The system is promising for less-painful and less-stressful 24-hour blood pressure monitoring in hypertension managements and related healthcare solutions.

  10. Difficulty in clinical identification of neonatal seizures: an EEG monitor study.

    PubMed Central

    Fenichel, G. M.

    1987-01-01

    Seventeen newborns were monitored for 24 hours using a three-channel ambulatory EEG (A/EEG). All newborns were thought to be having subtle seizures by the nursery staff. Fifteen of the 17 newborns were recorded as having 1-30 clinical seizures during the time of monitoring. Only one newborn had clinically identified seizures associated with A/EEG discharges. The seizures were characterized by eye rolling. Fifty-two episodes (thought to be seizures) of lip smacking, bicycling, jerking, fisting, staring, stiffening, or any combination of the above occurred in eight newborns without an associated discharge on A/EEG. However, two of the eight had seizure discharges at other times, not associated with any clinical manifestation. Seventy-four apnea spells, thought to be possible seizures, occurred in seven newborns. None was associated with discharges on A/EEG, but one of these newborns had 50 A/EEG discharges unrelated to apnea or other clinical manifestations. PMID:3577211

  11. New Methods for Personal Exposure Monitoring for Airborne Particles

    PubMed Central

    Koehler, Kirsten A.; Peters, Thomas

    2016-01-01

    Airborne particles have been associated with a range of adverse cardiopulmonary outcomes, which has driven its monitoring at stationary, central sites throughout the world. Individual exposures, however, can differ substantially from concentrations measured at central sites due to spatial variability across a region and sources unique to the individual, such as cooking or cleaning in homes, traffic emissions during commutes, and widely varying sources encountered at work. Personal monitoring with small, battery-powered instruments enables the measurement of an individual’s exposure as they go about their daily activities. Personal monitoring can substantially reduce exposure misclassification and improve the power to detect relationships between particulate pollution and adverse health outcomes. By partitioning exposures to known locations and sources, it may be possible to account for variable toxicity of different sources. This review outlines recent advances in the field of personal exposure assessment for particulate pollution. Advances in battery technology have improved the feasibility of 24-hour monitoring, providing the ability to more completely attribute exposures to microenvironment (e.g., work, home, commute). New metrics to evaluate the relationship between particulate matter and health are also being considered, including particle number concentration, particle composition measures, and particle oxidative load. Such metrics provide opportunities to develop more precise associations between airborne particles and health and may provide opportunities for more effective regulations. PMID:26385477

  12. An evaluation of daily bacteriologic monitoring to identify preventable episodes of catheter-associated urinary tract infection.

    PubMed

    Garibaldi, R A; Mooney, B R; Epstein, B J; Britt, M R

    1982-01-01

    We evaluated the efficacy of a daily bacteriologic monitoring program for preventing symptomatic urinary tract infections (UTI) in hospitalized patients with temporary indwelling urethral catheters. We identified 99 instances in which bacteriuria was present at the time of catheter insertion among 1,140 catheterizations. Of those, 62 patients were asymptomatic and 37 patients had fever or symptoms attributable to UTI. Of the 37 symptomatic episodes, only 14 developed symptoms 24 hours or more after the first culture and might be considered potentially preventable. We also identified 76 episodes of acquired bacteriuria among 608 catheterizations that were initially nonbacteriuric in which at least two cultures were available. Of these 76 patients, 51 (67%) remained asymptomatic throughout their period of hospitalization. Of the 25 patients who developed symptomatic infections, only ten were potentially preventable. In all, only 24 symptomatic episodes among 1,140 catheterizations (2%) occurred 24 hours or more after colonization was first detected and might be considered potentially preventable. Our data suggest that routine daily bacteriologic monitoring of urine from all catheterized patients is not an efficient way to decrease the incidence of symptomatic, catheter-associated UTI.

  13. Image acquisition system for traffic monitoring applications

    NASA Astrophysics Data System (ADS)

    Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben

    1995-03-01

    An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic

  14. Analysis of long term heart rate variability: methods, 1/f scaling and implications

    NASA Technical Reports Server (NTRS)

    Saul, J. P.; Albrecht, P.; Berger, R. D.; Cohen, R. J.

    1988-01-01

    The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.

  15. Guidelines on selection of laboratory tests for monitoring the acute phase response. International Committee for Standardization in Haematology (expert panel on blood rheology).

    PubMed Central

    1988-01-01

    These guidelines refer to laboratory tests for monitoring changes in acute phase proteins in patients with an inflammatory response to tissue damage. Quantitative measurements of acute phase proteins are a valuable indicator of the presence, extent, and response of inflammation to treatment. When short term (less than 24 hours) changes in the inflammatory response are expected, quantitative assay of C reactive protein is the test of choice. The hyperproteinaemia that develops in response to a longer term (more than 24 hours) inflammatory response is complex and may vary from one disease to another. A test that is sensitive to the combined effect of several plasma proteins is therefore indicated, and appropriate tests include the erythrocyte sedimentation rate and plasma viscosity--the latter having several advantages. Tests for monitoring short term and long term changes in acute phase proteins are complementary and should be used for different clinical purposes; no one test is ideal for all clinical situations. A quality control programme is an essential component of laboratory tests for monitoring the acute phase response. PMID:2463272

  16. The effect of colostrum ingestion during the first 24 hours of life on early postnatal development of piglet immune systems.

    PubMed

    Ogawa, Shohei; Tsukahara, Takamitsu; Imaoka, Taishi; Nakanishi, Nobuo; Ushida, Kazunari; Inoue, Ryo

    2016-12-01

    It has been suggested that colostrum is important not only for direct protection from pathogens but also for proper development of immune systems in piglets. In this study, we focused on the effect of colostrum ingestion during the first 24 h of life on early postnatal development of piglet immune systems. Thirty-six piglets from five litters were divided into colostrum-fed (CoF) and colostrum-deprived (CoD) groups. The former group was allowed to suckle normally while formula milk was fed to the latter group during the first 24 h of life. At the weaning period, the concentrations of fecal immunoglobulin (Ig) A and plasma IgG as well as the number of blood leukocyte subsets were analyzed. Fecal IgA and plasma IgG concentrations in the CoF group were more than twice as high as those in the CoD group (P < 0.01). In addition, the number of blood B cells was significantly higher in the CoF group than that in the CoD group (P < 0.05). This study demonstrates that colostrum ingestion during the first 24 h plays a significant role in early postnatal development of both mucosal and systemic immunity of piglets.

  17. Global Molecular and Morphological Effects of 24-Hour Chromium(VI)Exposure on Shewanella oneidensis MR-1

    SciTech Connect

    Chourey, Karuna; Thompson, Melissa R; Morrell-Falvey, Jennifer L; Verberkmoes, Nathan C; Brown, Steven D; Shah, Manesh B; Zhou, Jizhong; Doktycz, Mitchel John; Hettich, Robert {Bob} L; Thompson, Dorothea K

    2006-01-01

    The biological impact of 24-h ("chronic") chromium(VI) [Cr(VI) or chromate] exposure on ShewanellaoneidensisMR-1 was assessed by analyzing cellular morphology as well as genome-wide differential gene and protein expression profiles. Cells challenged aerobically with an initial chromate concentration of 0.3 mM in complex growth medium were compared to untreated control cells grown in the absence of chromate. At the 24-h time point at which cells were harvested for transcriptome and proteome analyses, no residual Cr(VI) was detected in the culture supernatant, thus suggesting the complete uptake and/or reduction of this metal by cells. In contrast to the untreated control cells, Cr(VI)-exposed cells formed apparently aseptate, nonmotile filaments that tended to aggregate. Transcriptome profiling and mass spectrometry-based proteomic charac terization revealed that the principal molecular response to 24-h Cr(VI) exposure was the induction of prophage-related genes and their encoded products as well as a number of functionally undefined hypothetical genes that were located within the integrated phage regions of the MR-1 genome. In addition, genes with annotated functions in DNA metabolism, cell division, biosynthesis and degradation of the murein (pepti doglycan) sacculus, membrane response, and general environmental stress protection were upregulated, while genes encoding chemotaxis, motility, and transport/binding proteins were largely repressed under conditions of 24-h chromate treatment.

  18. Interlaboratory validation of a real-time PCR 24-hour rapid method for detection of Salmonella in foods.

    PubMed

    Cheng, Chorng-Ming; Van Khanh, T; Lin, Wen; Ruby, Richard M

    2009-05-01

    The efficacy of a 24-h Salmonella real-time, or quantitative, PCR (qPCR) detection method was assessed through a collaborative effort involving eight Federal and state laboratories. Eleven foods including mashed potatoes, soft cheese, chili powder, chocolate, eggs, sprouts, apple juice, fish, shrimp, ground beef, and ground chicken were tested. For each food, seven blind samples were distributed to each participant for testing. These included six samples equivalently inoculated with 1 to 5 CFU/25 g of various serotypes of Salmonella (Gaminara, Weltevreden, Heidelberg, Senftenberg, Enteritidis, Newport, Typhimurium, and Kentucky for each food) and 10 to 50 CFU/25 g of the competitor Enterobacter cloacae. The seventh sample was inoculated with 10 to 50 CFU/25 g of the competitor, E. cloacae, only. These samples were tested for Salmonella by using four methods in parallel: (i) 24-h qPCR method detecting Salmonella from modified buffered peptone water enrichment medium; (ii) 48-h qPCR method detecting Salmonella from a secondary selective enrichment broth; (iii) modified Bacteriological Analytical Manual method; and (iv) VIDAS, an immunoassay system. The results of the statistical analysis showed there was no significant (P > or = 0.05) difference between either of the qPCR methods and the modified Bacteriological Analytical Manual method for 10 of 11 foods. For the one exception, sprouts, detection by qPCR required 48 h. Both qPCR methods showed a detection limit of 0.08 to 0.2 CFU/g. These results provide a solid basis for using this 24-h qPCR rapid screening method to detect Salmonella in foods.

  19. Validation of the Portuguese self-administered computerised 24-hour dietary recall among second-, third- and fourth-grade children

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Current methods for assessing children's dietary intake, such as interviewer-administered 24-h dietary recall (24-h DR), are time consuming and resource intensive. Self-administered instruments offer a low-cost diet assessment method for use with children. The present study assessed the validity of ...

  20. The complexity of pain assessment and management in the first 24 hours after cardiac surgery: implications for nurses. Part I.

    PubMed

    Hancock, H

    1996-10-01

    Pain has been recognised as a problem within the realms of health care for many years (Szanto & Heaman 1972, Melzack 1973). The management of pain in the immediate postoperative period remains one of the most serious inadequacies of health care today (Royal College of Surgeons 1990). Recent evidence suggests that up to 75% of hospitalised patients fail to receive adequate pain relief (Carr 1990), with postoperative cardiac patients reporting detailed recollections of their pain experiences during their stay in critical care areas (Ferguson 1992). To accountable health care professionals these figures are humiliating and cannot be allowed to continue (Hollinworth 1994). Indeed, the persistance of postoperative pain can seriously compromise the status of postoperative cardiac patients (Wild 1992). An exploration of current practices in pain management for adult individuals following cardiac surgery included a review of the methods of assessment and treatment interventions employed at three English critical care units. With the literature providing substantial evidence of research into post-operative pain management the persistence of postoperative pain was questioned. Inadequacies in nursing knowledge were identified in all areas of postoperative pain management. The persistence of the theory-practice gap was identified as a major factor contributing to the maintenance of current practice. Similarly, the inappropriate use of change strategies, aimed ultimately at enhancing patient care, proved significant. The findings, which show neglect of the nursing responsibility for the provision of research-based, high quality patient care, carry implications for all nurses. Recommendations including the development of new strategies for the inclusion of existing knowledge into practice appear vital, in order that clinical practice, and ultimately patient care, can be enhanced.

  1. Estimated amount of 24-hour urine sodium excretion is positively correlated with stomach and breast cancer prevalence in Korea.

    PubMed

    Park, Jung Hwan; Kim, Yong Chul; Koo, Ho Seok; Oh, Se Won; Kim, Suhnggwon; Chin, Ho Jun

    2014-09-01

    Stomach cancer is one of the most common cancers in Korea. The aim of this study was to identify the association between the prevalence of cancer, particularly stomach cancer, and the amount of 24-hr urine sodium excretion estimated from spot urine specimens. The study included 19,083 subjects who took part in the Korean National Health and Nutritional Examination Survey between 2009 and 2011. The total amount of urine sodium excreted in a 24-hr period was estimated by using two equations based on the values for spot urine sodium and creatinine. In subjects who had an estimated 24-hr urine sodium excretion of more than two standard deviations above the mean (group 2), the prevalence of stomach cancer was higher than in subjects with lower 24-hr sodium excretion (group 1). By using the Tanaka equation to estimate it, the prevalence of stomach cancer was 0.6% (114/18,331) in group 1, whereas it was 1.6% (9/568) in group 2 (P=0.006). By using the Korean equation, the prevalence was 0.6% (115/18,392) in group 1, and 1.6% in group 2 (8/507) (P=0.010). By using the Tanaka equation, breast cancer in women is more prevalent in group 2 (1.9%, 6/324) than group 1 (0.8%, 78/9,985, P=0.039). Higher salt intake, as defined by the estimated amount of 24-hr urine sodium excretion, is positively correlated with a higher prevalence of stomach or breast cancer in the Korean population.

  2. [24-hour work: the interaction of stress and changes in the sleep-wake cycle in the police force].

    PubMed

    Garbarino, Sergio

    2014-01-01

    Disruption in police officers. In recent years there has been a widespread growth in services, available regardless of time or day organization (24/7 service) and a diffuse increase in their use, both in work and private lives, generally ignoring the importance of a regular sleep organization. Police officers - often need to work extended shifts and long hours under highly stressful conditions, which results in reduced levels of safety and operational effectiveness. In numerous studies, perceived stress has been found to correlate with both subjective and objective disturbances in sleep. Consequently, excessive daytime sleepiness is one of the most frequent health and safety hazards that police officers have to deal with. Sleep deprivation affects performance outcomes through a wide range of cognitive domains. Sleepiness and fatigue, caused by sleep loss, extended work and wakefulness, circadian misalignment and sleep disorders are major causes of workplace human errors, incidents, and accidents. Therefore, prevention of sleep loss, high levels of stress and fatigue is a key factor to consider when assessing emergency intervention. In order to combat fatigue and sleepiness, a 30-90 minutes nap before night shift could be a viable option.

  3. Recurrent Bleeding Within 24 Hours After Uterine Artery Embolization for Severe Postpartum Hemorrhage: Are There Predictive Factors?

    SciTech Connect

    Bros, Sebastien Chabrot, Pascal Kastler, Adrian; Ouchchane, Lemlih; Cassagnes, Lucie; Gallot, Denis; Boyer, Louis

    2012-06-15

    Purpose: To retrospectively identify predictive factors of recurrent bleeding within 24 h after uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: A total of 194 patients underwent UAE for PPH between August 1999 and April 2009 at our institution. Twelve patients experienced recurrent bleeding within the next 24 h; a second attempt at UAE was thus necessary, which was successful in 10 cases. In two cases, hemostatic hysterectomy was performed. Epidemiological, gynecological-obstetrical, anatomic, and biological data were analyzed. Results: Complete data were available for 148 of the 194 (76%) included patients. Sixty-four (43%) were primiparous, 18 (12.2%) had a placenta accreta, 21 (14%) had a coagulopathy, and 28 (18.9%) had an anatomic variant of the uterine arterial vasculature. Mean age and pregnancy term were similar in both recurring and nonrecurrent bleeding groups. After multivariate analysis, three criteria emerged as risk factors of recurrent bleeding: primiparity (10 patients, 83%; odds ratio [OR] = 18.84; P = 0.014), coagulation disorders (6 patients, 50%; OR = 12.08; P = 0.006), and anatomic variant of the uterine arterial vasculature (28 patients; OR = 9.83; P = 0.003). Conclusions: earch for uterine collaterals must be performed before UAE for PPH. Primiparity and coagulation disorders increase the risk of recurrent bleeding after UAE for PPH.

  4. Evaluation of prefrontal—hippocampal effective connectivity following 24 hours of estrogen infusion: An FDG-PET study

    PubMed Central

    Ottowitz, William E.; Siedlecki, Karen L.; Lindquist, Martin A.; Dougherty, Darin D.; Fischman, Alan J.; Hall, Janet E.

    2009-01-01

    Summary Although several functional neuroimaging studies have addressed the relevance of hormones to cerebral function, none have evaluated the effects of hormones on network effective connectivity. Since estrogen enhances synaptic connectivity and has been shown to drive activity across neural systems, and because the hippocampus and prefrontal cortex (PFC) are putative targets for the effects of estrogen, we hypothesized that effective connectivity between these regions would be enhanced by an estrogen challenge. In order to test this hypothesis, FDG-PET scans were collected in eleven postmenopausal women at baseline and 24 h after a graded estrogen infusion. Subtraction analysis (SA) was conducted to identify sites of increased cerebral glucose uptake (CMRglc) during estrogen infusion. The lateral PFC and hippocampus were a priori sites for activation; SA identified the right superior frontal gyrus (RSFG; MNI coordinates 18, 60, 28) (SPM2, Wellcome Dept. of Cognitive Neurology, London, UK) as a site of increased CMRglc during estrogen infusion relative to baseline. Omnibus covariate analysis conducted relative to the RSFG identified the right hippocampus (MNI coordinates: 32, −32, −6) and right middle frontal gyrus (RMFG; MNI coordinates: 40, 22, 52) as sites of covariance. Path analysis (Amos 5.0 software) revealed that the path coefficient for the RSFG to RHIP path differed from zero only during E2 infusion (p < 0.05); moreover, the magnitude of the path coefficient for the RHIP to RMFG path showed a significant further increase during the estrogen infusion condition relative to baseline [Δχ2 = 4.05, Δd.f. = 1, p = 0.044]. These findings are consistent with E2 imparting a stimulatory effect on effective connectivity within prefrontal—hippocampal circuitry. This holds mechanistic significance for resting state network interactions and may hold implications for mood and cognition. PMID:18977091

  5. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    DOE PAGES

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; ...

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analyticalmore » methods employed and is related to [4].« less

  6. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    SciTech Connect

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4].

  7. Unilateral nephrectomy 24 hours after bilateral kidney irradiation reduces damage to the function and structure of the remaining kidney

    SciTech Connect

    Liao, Z.X.; Travis, E.L.

    1994-09-01

    The effect of unilateral nephrectomy 24 h after irradiation on renal function and death with renal insufficiency as well as histopathological changes in the kidney was assessed. Single doses totaling 8-18 Gy were given bilaterally to unanesthetized female and male C3Hf/Kam mice. Renal function damage was assayed by blood urea nitrogen (BUN) and hematocrit (Hct). Histological damage was quantified by two parameters: kidney area and number of surviving tubule cells along the renal capsule. The number of glomeruli was scored as an indication of the number of nephrons. Changes in the two functional parameters did not appear sooner after irradiation in the nephrectomized mice than in the non-nephrectomized mice. Rather, less impairment of function was measured by both parameters in the nephrectomized mice but only after radiation doses greater than 12 Gy. The LD{sub 50} at 424 days after irradiation was also higher in the nephrectomized mice than in the mice receiving only irradiation, 13.98 Gy (95% confidence limits = 12.03, 15.93) and 11.71 Gy (95% confidence limits = 10.4, 13.1), respectively, in agreement with the data on function. Unilateral nephrectomy alone induced a 10% increase in size of the contralateral kidney. The dose-response curve for the kidney area from nephrectomized mice was parallel to and displaced above that for non-nephrectomized mice, indicating that the increase in renal mass occurred independent of and was not compromised by radiation. Unilateral nephrectomy alone induced no increase in the number of proximal tubules in the contralateral kidney. 30 refs., 9 figs., 1 tab.

  8. Use of phosphadtidylcholine to improve the function of turkey semen stored at 4 °C for 24 hours

    Technology Transfer Automated Retrieval System (TEKTRAN)

    It has been long recognized that the ability to store turkey semen for 24h in vitro without a significant loss in fertility upon insemination would benefit the commercial turkey industry. We investigated the use of exogenous phosphatidylcholine (PC) to (1) prevent the loss of phospholipids from the...

  9. What a Difference a Day Makes: Change in Memory for Newly Learned Word Forms over 24 Hours

    ERIC Educational Resources Information Center

    McGregor, Karla K.

    2014-01-01

    Purpose: This study explored the role of time and retrieval experience in the consolidation of word forms. Method: Participants were 106 adults trained on 16 novel word-referent pairs, then tested immediately and 24 hr later for recognition and recall of word forms. In the interim, tests were repeated 2 hr or 12 hr after training, or not at all,…

  10. A new experimental trial using repeated heating every 24 hours for local hyperthermic therapy with bleomycin in vivo.

    PubMed

    Yamashita, Y; Hirai, T; Mukaida, H; Iwata, T; Toge, T; Hoon, H J

    1990-11-01

    This report presents the effect of repeated heating every 24 hrs using bleomycin (BLM) which, although seemingly contrary to the usual agreement that hyperthermia should be carried out with a long interval due to thermotolerance, holds many possibilities. FM3A cells on the foot pad of C3H mouse were immersed in a heated water bath at 43 and 44 degrees C for 30 min. The effect of repeated heating was appreciated by an improved growth curve and 50 day survival compared to mice which received heating twice with a 96-hr interval. Repeated heating every 24 hrs 5 times with BLM suppressed tumor growth significantly as compared to heating twice with a 96-hr interval without BLM. The longest survival time was obtained by the repeated heating with BLM among all protocols. There is therefore a good possibility that more effective results could be obtained clinically by repeated heating over a short period.

  11. Owens Valley Serious Area Plan for the 1987 24-Hour PM10; Final Approval of California Air Plan

    EPA Pesticide Factsheets

    EPA is taking final action to approve a state implementation plan (SIP) revision submitted by the State of California to meet Clean Air Act equirements applicable to the Owens Valley PM10 nonattainment area.

  12. Successful Non-Surgical Deep Uterine Transfer of Porcine Morulae after 24 Hour Culture in a Chemically Defined Medium

    PubMed Central

    Martinez, Emilio A.; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25°C and 37°C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5°C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25°C but not at 37°C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37°C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37°C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0±0.6 and 9.4±0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs. PMID:25118944

  13. Successful non-surgical deep uterine transfer of porcine morulae after 24 hour culture in a chemically defined medium.

    PubMed

    Martinez, Emilio A; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25 °C and 37 °C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5 °C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25 °C but not at 37 °C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37 °C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37 °C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0 ± 0.6 and 9.4 ± 0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs.

  14. Pain Levels Within 24 Hours After UFE: A Comparison of Morphine and Fentanyl Patient-Controlled Analgesia

    SciTech Connect

    Kim, Hyun S. Czuczman, Gregory J.; Nicholson, Wanda K.; Pham, Luu D.; Richman, Jeffrey M.

    2008-11-15

    The purpose of this study was to assess the presence and severity of pain levels during 24 h after uterine fibroid embolization (UFE) for symptomatic leiomyomata and compare the effectiveness and adverse effects of morphine patient-controlled analgesia (PCA) versus fentanyl PCA. We carried out a prospective, nonrandomized study of 200 consecutive women who received UFE and morphine or fentanyl PCA after UFE. Pain perception levels were obtained on a 0-10 scale for the 24-h period after UFE. Linear regression methods were used to determine pain trends and differences in pain trends between two groups and the association between pain scores and patient covariates. One hundred eighty-five patients (92.5%) reported greater-than-baseline pain after UFE, and 198 patients (99%) required IV opioid PCA. One hundred thirty-six patients (68.0%) developed nausea during the 24-h period. Seventy-two patients (36%) received morphine PCA and 128 (64%) received fentanyl PCA, without demographic differences. The mean dose of morphine used was 33.8 {+-} 26.7 mg, while the mean dose of fentanyl was 698.7 {+-} 537.4 {mu}g. Using this regimen, patients who received morphine PCA had significantly lower pain levels than those who received fentanyl PCA (p < 0.0001). We conclude that patients develop pain requiring IV opioid PCA within 24 h after UFE. Morphine PCA is more effective in reducing post-uterine artery embolization pain than fentanyl PCA. Nausea is a significant adverse effect from opioid PCA.

  15. Phase shift in the 24-hour rhythm of hippocampal EEG spiking activity in a rat model of temporal lobe epilepsy

    PubMed Central

    Stanley, David A.; Talathi, Sachin S.; Parekh, Mansi B.; Cordiner, Daniel J.; Zhou, Junli; Mareci, Thomas H.; Ditto, William L.

    2013-01-01

    For over a century epileptic seizures have been known to cluster at specific times of the day. Recent studies have suggested that the circadian regulatory system may become permanently altered in epilepsy, but little is known about how this affects neural activity and the daily pattern of seizures. To investigate, we tracked long-term changes in the rate of spontaneous hippocampal EEG spikes (SPKs) in a rat model of temporal lobe epilepsy. In healthy animals, SPKs oscillated with near 24-h period; however, after injury by status epilepticus, a persistent phase shift of ∼12 h emerged in animals that later went on to develop chronic spontaneous seizures. Additional measurements showed that global 24-h rhythms, including core body temperature and theta state transitions, did not phase shift. Instead, we hypothesized that locally impaired circadian input to the hippocampus might be responsible for the SPK phase shift. This was investigated with a biophysical computer model in which we showed that subtle changes in the relative strengths of circadian input could produce a phase shift in hippocampal neural activity. MRI provided evidence that the medial septum, a putative circadian relay center for the hippocampus, exhibits signs of damage and therefore could contribute to local circadian impairment. Our results suggest that balanced circadian input is critical to maintaining natural circadian phase in the hippocampus and that damage to circadian relay centers, such as the medial septum, may disrupt this balance. We conclude by discussing how abnormal circadian regulation may contribute to the daily rhythms of epileptic seizures and related cognitive dysfunction. PMID:23678009

  16. Effect of metoprolol on 24-hour urinary excretion of adrenal steroids and kallikrein in patients with essential hypertension.

    PubMed Central

    Fritschka, E.; Gotzen, R.; Kittler, R.; Schöneshöfer, M.

    1984-01-01

    Treatment of fifteen patients with essential hypertension over four weeks using the beta 1-adrenoceptor blocking agent, metoprolol, resulted in a decrease in 24 h urinary excretion of kallikrein and aldosterone along with a decrease in plasma renin activity. There was no significant change in 24 h excretion rates of the free adrenal steroids deoxycorticosterone, 18-OH-deoxycorticosterone, corticosterone, cortisol or 18-OH-corticosterone during treatment, which were not significantly different from excretion rates of normal males, thus excluding inhibitory effects of adrenal steroids on urinary kallikrein activity. A positive correlation was found between plasma renin activity and urinary excretion of kallikrein during the control period and after 2 weeks on metoprolol, supporting the assumption of a preserved link between the renin-angiotensin-aldosterone system and the renal excretion of kallikrein in these patients. The decrease in kallikrein excretion during beta 1-adrenoceptor blockade in patients with essential hypertension may be explained by a reduction in sympathetic tone and by reduced activity of the renin-aldosterone system. PMID:6367871

  17. Effects on Asian Citrus Psyllid (Diaphorina citri Kuwayama) feeding behavior of fenpropathrin and chlorpyrifos within 24 hours of application

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Huanglongbing (HLB), also known as citrus greening disease, is one of the most destructive diseases affecting citrus production. The phloem-limited bacterium associated with HLB is transmitted by the Asian citrus psyllid, Diaphorina citri Kuwayama (Hemiptera: Psyllidae). One component of HLB managem...

  18. POTENTIATION OF PULMONARY REFLEX RESPONSE TO CAPSAICIN 24 HOURS FOLLOWING WHOLE-BODY ACROLEIN EXPOSURE IS MEDIATED BY TRPV1

    EPA Science Inventory

    Pulmonary C-fibers are stimulated by irritant air pollutants producing apnea, bronchospasm, and decrease in HR. C-fiber chemoreflex activation is mediated by TRPV1 and release of substance P. While acrolein has been shown to stimulate C-fibers, the persistence of acrolein effect...

  19. Changes in CSF hypocretin-1 (orexin A) levels in rats across 24 hours and in response to food deprivation.

    PubMed

    Fujiki, N; Yoshida, Y; Ripley, B; Honda, K; Mignot, E; Nishino, S

    2001-04-17

    Hypocretin-1 is consistently detectable in the CSF of healthy human subjects, but is absent in narcoleptics. However, functional roles of CSF hypocretin are largely unknown. We examined fluctuation of CSF hypocretin-1 across 24 h and in response to food restriction in rats. Hypocretin-1 levels were high during the dark period when animals were active, but decreased by 40% toward the end of the light (rest) period. After 72 h food deprivation hypocretin-1 levels during the rest phase increased to concentrations similar to those seen during the baseline active phase; however, no increase in response to food deprivation was observed during the active phase. These results indicate an important link between circadian control of sleep and energy homeostasis via the hypocretin system.

  20. What Do I Do With Him 24 Hours a Day? Changes in the Housewife Role After Retirement.

    ERIC Educational Resources Information Center

    Keating, Norah C.; Cole, Priscilla

    Retirement is a life cycle phase most couples can now expect to experience. Research on retirement has been directed primarily toward the impact of retirement on the retiree, rather than on the marital dyad. Qualitative and quantitative changes that women experience were investigated, with regards to their role as wife in response to their…

  1. What a Difference a Day Makes: Change in Memory for Newly Learned Word Forms Over 24 Hours

    PubMed Central

    McGregor, Karla K.

    2014-01-01

    Purpose This study explored the role of time and retrieval experience in the consolidation of word forms. Method Participants were 106 adults trained on 16 novel word-referent pairs, then tested immediately and 24 hr later for recognition and recall of word forms. In the interim, tests were repeated 2 hr or 12 hr after training, or not at all, thus varying the amount and timing of retrieval experience. Results Recognition accuracy was stable and speed improved over the 24-hr period. But these manifestations of consolidation did not depend on interim retrieval experience; in fact, the 2-hr interim test interfered with improvements in speed. In contrast, the number of word forms recalled increased only with interim retrieval experiences, and the 12-hr interim test was more advantageous to recall than the 2-hr test. Conclusions After a word form is encoded, it can become stronger with time. Retrieval experience can also strengthen the trace, but, if retrieval occurs when the memory is still labile, it can be disruptive. This complex interplay between retrieval experience and time holds implications for measuring learning outcomes and for scheduling practice in classrooms and clinics. PMID:24845578

  2. Lessons from Studies to Evaluate an Online 24-Hour Recall for Use with Children and Adults in Canada

    PubMed Central

    Kirkpatrick, Sharon I.; Gilsing, Anne M.; Hobin, Erin; Solbak, Nathan M.; Wallace, Angela; Haines, Jess; Mayhew, Alexandra J.; Orr, Sarah K.; Raina, Parminder; Robson, Paula J.; Sacco, Jocelyn E.; Whelan, Heather K.

    2017-01-01

    With technological innovation, comprehensive dietary intake data can be collected in a wide range of studies and settings. The Automated Self-Administered 24-h (ASA24) Dietary Assessment Tool is a web-based system that guides respondents through 24-h recalls. The purpose of this paper is to describe lessons learned from five studies that assessed the feasibility and validity of ASA24 for capturing recall data among several population subgroups in Canada. These studies were conducted within a childcare setting (preschool children with reporting by parents), in public schools (children in grades 5–8; aged 10–13 years), and with community-based samples drawn from existing cohorts of adults and older adults. Themes emerged across studies regarding receptivity to completing ASA24, user experiences with the interface, and practical considerations for different populations. Overall, we found high acceptance of ASA24 among these diverse samples. However, the ASA24 interface was not intuitive for some participants, particularly young children and older adults. As well, technological challenges were encountered. These observations underscore the importance of piloting protocols using online tools, as well as consideration of the potential need for tailored resources to support study participants. Lessons gleaned can inform the effective use of technology-enabled dietary assessment tools in research. PMID:28146125

  3. Modeling the toxicokinetics of 24-hour toluene exposure in rats, impact of activity patterns and enzyme induction

    EPA Science Inventory

    Toluene, a solvent used in numerous consumer and industrial applications, exerts its critical effects on the brain and nervous system following inhalation exposure. Our previously published PBPK model successfully predicted toluene concentrations in blood and brain over a range o...

  4. 76 FR 6056 - Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... Order Reviews A. Executive Order 12866: Regulatory Planning and Review B. Paperwork Reduction Act C... and is subject to CAA section 107(d)(2)(B), which does not require that the Agency issue a notice of.../attainment,'' while a portion of Pinal County is being designated as ``nonattainment.'' This action...

  5. Spinal cord fusion with PEG-GNRs (TexasPEG): Neurophysiological recovery in 24 hours in rats

    PubMed Central

    Kim, C-Yoon; Sikkema, William K. A.; Hwang, In-Kyu; Oh, Hanseul; Kim, Un Jeng; Lee, Bae Hwan; Tour, James M.

    2016-01-01

    Background: The GEMINI spinal cord fusion protocol has been developed to achieve a successful cephalosomatic anastomosis. Here, for the first time, we report the effects of locally applied water-soluble, conductive PEG(polyethylene glycol)ylated graphene nanoribbons (PEG-GNRs) on neurophysiologic conduction after sharp cervical cord transection in rats. PEG-GNRs were produced by the polymerization of ethylene oxide from anion-edged graphene nanoribbons. These combine the fusogenic potential of PEG with the electrical conducting properties of the graphene nanoribbons. Methods: Laminectomy and transection of cervical spinal cord (C5) was performed on Female Sprague-Dawley (SD) rats. After applying PEG-GNR on the severed part, electrophysiological recovery of the reconstructed cervical spinal cord was confirmed by somatosensory evoked potentials (SSEPs) at 24 h after surgery. Results: While no SSEPs were detected in the control group, PEG-GNR treated group showed fast recovery of SSEPs at 24 h after the surgery. Conclusion: In this preliminary dataset, for the first time, we report the effect of a novel form of PEG with the goal of rapid reconstruction of a sharply severed spinal cord. PMID:27656326

  6. Elimination of Asian fish tapeworms from grass carp with praziquantel bath treatments: The need for 24 hour exposures

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Several states require that imported fish be free of the Asian fish tapeworm Bothriocephalus acheilognathi. Praziquantel has been used for several years to treat fish with Asian fish tapeworms but rates and exposure periods necessary to eliminate these tapeworms from infected fish have not been ade...

  7. Excretion of beta-carbolines harman and norharman in 24-hour urine of chronic alcoholics during withdrawal and controlled abstinence.

    PubMed

    Wodarz, N; Wiesbeck, G A; Rommelspacher, H; Riederer, P; Böning, J

    1996-06-01

    Animal experiments suggest that endogenous substances that could result from the interaction between neurotransmitters (dopamine and indoleamines) and ethanol and its metabolite acetaldehyde might be involved in the pathogenesis and maintenance of alcohol dependence. Therefore, aromatic beta-carbolines (norharman and harman) were investigated repeatedly in 24-hr urine of 13 male severe alcoholics without any psychiatric comorbidity during a controlled inpatient abstention program of up to 8 weeks. Harman excretion was approximately 2-fold above levels in control subjects, with a steady decline after 3 weeks of abstinence and lower levels in patients with a longer duration of alcohol dependence. Severity of withdrawal symptoms and actual feelings of anxiety/depression were negatively associated with urinary harman excretion. Positive associations could be established with daily ethanol consumption the month before admission and the score on the scale "reward dependence" according to Cloninger's Tridimensional Personality Questionnaire. Moreover, patients without alcohol-dependent first-degree relatives and higher "reward dependence" exhibited an increased excretion of harman. Therefore, harman levels might characterize a distinct subgroup of alcoholic patients, who in part resemble the so-called type l alcoholics of Cloninger. However, this awaits further study in a larger number of individuals. In contrast, norharman excretion was elevated up to 6-fold, compared with nonalcoholics over 6 to 8 weeks of controlled abstention. No correlations to demographic or clinical variables could be observed. Therefore, increased norharman levels might be proposed as a "residual marker" or a trait variable. Whether the observed changes are specific markers of at least certain aspects of alcoholism or dependence remain to be elucidated.

  8. The effect of static applied potential on the 24-hour impedance behavior of commercially pure titanium in simulated biological conditions.

    PubMed

    Ehrensberger, Mark T; Gilbert, Jeremy L

    2010-04-01

    Potential step impedance analysis was utilized to evaluate the electrochemical impedance of commercially pure titanium (cpTi) samples that were polarized to static potentials (range from -1000 mV to +1000 mV vs. Ag/AgCl) and immersed in physiologically relevant electrolytes [phosphate buffered saline (PBS) and cell culture medium with 10% fetal bovine serum (AMEM + FBS)] for 24 hrs. The cpTi impedance outcomes were a complex function of voltage, solution constituents, and immersion time. In the 0 mV to +1000 mV range, oxide growth was observed over 24 hr immersion in both solutions based on decreasing current density (approximately 10(-6) A/cm(2) to approximately 10(-8) A/cm(2)) and increasing R(p) (200 kOmega cm(2) to approximately 10 MOmega cm(2)). Below 0 mV, the 24 hr R(p) decreased with negative potential to approximately 15 kOmega cm(2). After 24 hr immersion, oxide dissolution and/or adsorption of organic species caused the capacitance to increase at -1000 mV (AMEM + FBS & PBS) and at -600 mV (AMEM + FBS only). Twenty-four hours of immersion in AMEM + FBS at -1000 mV and -600 mV produced a surface coloration that is likely due to alteration of oxide valance state and/or doping level. This work shows that Ti surface oxide and its electrochemical behavior can be altered dramatically under sustained cathodic potentials.

  9. Effect of captopril and melatonin on fibrotic rebuilding of the aorta in 24 hour light-induced hypertension.

    PubMed

    Repová-Bednárová, K; Aziriová, S; Hrenák, J; Krajčírovičová, K; Adamcová, M; Paulis, L; Simko, F

    2013-01-01

    Chronic continuous light exposure leads to melatonin deficiency along with complex neurohumoral activation resulting in hypertension development in rats. The aim of this study was to show, whether continuous light induces fibrotic rebuilding of the aorta and whether the treatment with melatonin or angiotensin converting enzyme inhibitor captopril can prevent these potential alterations. In a six-week experiment, 3-month-old Wistar rats were divided into 4 groups (ten per group): controls, rats exposed to continuous light, exposed to continuous light plus treated with captopril (100 mg/kg/24 h) and exposed to continuous light plus treated with melatonin (10 mg/kg/24 h). Systolic blood pressure (SBP) and collagen type I and III in the media of thoracic aorta were measured. Continuous light induced hypertension and fibrotic rebuilding of the aorta in terms of enhancement of collagen I and III concentration in the aortic media. Both captopril and melatonin prevented SBP rise and reduced collagen III concentration in the aorta. However, only melatonin reduced collagen I and the sum of collagen I and III in the aortic tissue. We conclude that in continuous light-induced hypertension, administration of melatonin, along with SBP reduction, decreases collagen I and III concentration in the aorta. It is suggested that antifibrotic effect of melatonin may reduce the stiffness of the aorta and small arteries and beneficially influence the nature of the pulse wave and peripheral vascular resistance.

  10. Psychological evaluation of 24-hour home nursing care: application of an analytic hierarchy process to improve quality of life.

    PubMed

    Shibata, Takeo; Shimizu, Yoko; Wada, Hiroko

    2012-01-01

    Twenty-four-hour home nursing care services for patients with severe diseases such as amyotrophic lateral sclerosis have been started in Japan. To improve the quality of home nursing care as well as the patients quality of life (QOL), we undertook a psychological evaluation of the care services. An analytic hierarchy process (AHP) was applied to the psychological evaluation. Forty-eight staff replied to our questionnaire, of which twenty-nine staff showed a consistency index of less than 0.1. In the first hierarchy, the intensities of importance were 0.436 for "quality of care", 0.351 for "staff awareness", and 0.213 for "economic efficiency". Most staff appeared to feel that the relationships among patients, their families, and staffs were the most important criteria. While many staff might have increased their "physical profit" and "burden", the intensities of importance for those criteria were low.

  11. Thyroid uptake and imaging with iodine-123 at 4-5 hours: replacement of the 24-hour iodine-131 standard

    SciTech Connect

    Floyd, J.L.; Rosen, P.R.; Borchert, R.D.; Jackson, D.E.; Weiland, F.L.

    1985-08-01

    A study was carried out to determine the suitability of utilizing a 4 to 5 hr interval from administration of Iodine-123 to imaging and uptake measurement as a replacement for the 24-hr standard originally established with Iodine-131. In 55 patients who underwent scintigraphy at 4 and 24 hr, there was no discrepancy between paired images. In 55 patients who had uptake measured at 4 and 24 hr and in 191 patients who had uptake measured at 5 and 24 hr, the early measurements proved equal or better discriminants of euthyroid from hyperthyroid patients. In our institutions, these findings and the logistical advantages of completing the exam in 4-5 hr led us to abandon the 24-hr study in the majority of patients.

  12. Physical activity monitoring in obese people in the real life environment

    PubMed Central

    2009-01-01

    Background Obesity is a major problem especially in western countries and several studies underline the importance of physical activity to enhance diet. Currently there is increasing interest in instruments for monitoring daily physical activity. The purpose of this pilot study was to appraise the qualitative and quantitative differences in physical activities and gait analysis parameters in control and obese subjects by means of an innovative tool for the monitoring of physical activity. Methods Twenty-six obese patients, 16 women and 10 men, aged 22 to 69 years with Body Mass Index (BMI) between 30 and 51.4 kg/m2, were compared with 15 control subjects, 4 men and 11 women, aged 24 to 69 with BMI between 18 and 25 kg/m2 during daily physical activities. The IDEEA device (Minisun, Fresno, CA), based on a wearable system of biaxial accelerometers and able to continuously record the physical activities and energy expenditure of a subject in time was used. Time spent in different physical activities such as standing, sitting, walking, lying, reclining, stepping, energy expenditure and gait parameters (velocity, stance duration, etc) were measured during a 24-hours period. Results A trend toward a reduced number of steps was present, associated to reduced speed, reduced cadence and reduced rate of single and double limb support (SLS/DLS). Moreover, obese people spent significant less time stepping, less time lying and more time in a sitting or reclined position during the night. The energy expenditure during a 24-hours period was higher in the obese compared to controls. Conclusions The study provided objective parameters to differentiate the daily motor activity of obese subjects with respect to controls, even a larger population is required to confirm these findings. The device used can be of support in programming educational activities for life style modification in obese people as well as for monitoring the results of various kinds of intervention in these

  13. A Wearable Context-Aware ECG Monitoring System Integrated with Built-in Kinematic Sensors of the Smartphone

    PubMed Central

    Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye

    2015-01-01

    Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user’s physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone. PMID:25996508

  14. Authenticated tracking and monitoring system (ATMS) tracking shipments from an Australian uranium mine

    SciTech Connect

    Schoeneman, J.L.

    1998-08-01

    The Authenticated Tracking and Monitoring System (ATMS) answers the need for global monitoring of the status and location of sensitive items on a worldwide basis, 24 hours a day. ATMS uses wireless sensor packs to monitor the status of the items and environmental conditions. A receiver and processing unit collect a variety of sensor event data. The collected data are transmitted to the INMARSAT satellite communication system, which then sends the data to appropriate ground stations. Authentication and encryption algorithms secure the data during communication activities. A typical ATMS application would be to track and monitor the safety and security of a number of items in transit along a scheduled shipping route. The resulting tracking, timing, and status information could then be processed to ensure compliance with various agreements. Following discussions between the Australian Safeguards Office (ASO), the US Department of Energy (DOE), and Sandia National Laboratories (SNL) in early 1995, the parties mutually agreed to conduct and evaluate a field trial prototype ATMS to track and monitor shipments of uranium ore concentrate (UOC) from an operating uranium mine in Australia to a final destination in Rotterdam, the Netherlands, with numerous stops along the way. During the months of February and March 1998, the trial was conducted on a worldwide basis, with tracking and monitoring stations located at sites in both Australia and the US. This paper describes ATMS and the trial.

  15. Motion-based wake-up scheme for ambulatory monitoring in wireless body sensor networks.

    PubMed

    Pek, Isaac; Waluyo, Agustinus Borgy; Yeoh, Wee-Soon; Chen, Xiang

    2009-01-01

    Given that wearable sensors that are attached on patients for the purpose of continuous real-time medical monitoring typically need to remain operational for periods of up to 24 hours before a battery change or recharge, power preservation schemes play a critical role in minimizing any possible disruption to a patient's daily activities. In this paper, we propose a motion-based wake-up scheme, a feature which combines motion detection with existing power preservation schemes in order to achieve a balance between energy saving and data timeliness, particularly in critical situations. As a showcase, we have integrated this feature with a healthcare application and demonstrate the capability of the scheme to deal with critical events, e.g., when a patient falls down from the bed. This showcase affirms the effective uses of our proposed motion-based wake-up scheme.

  16. Bladder Monitor

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Diagnostic Ultrasound Corporation's Bladder Scan Monitor continuously records and monitors bladder fullness and alerts the wearer or caretaker when voiding is required. The sensor is held against the lower abdomen by a belt and connected to the monitor by a cable. The sensor obtains bladder volume data from sound waves reflecting off the bladder wall. The device was developed by Langley Research Center, the Ames Research Center and the NASA Technology Applications Team. It utilizes Langley's advanced ultrasound technology. It is licensed to the ARC for medical applications, and sublicensed to Diagnostics Ultrasound. Central monitoring systems are planned for the future.

  17. Use of ambulatory blood pressure monitoring to compare antihypertensive efficacy and safety of two angiotensin II receptor antagonists, losartan and valsartan. Losartan Trial Investigators.

    PubMed

    Monterroso, V H; Rodriguez Chavez, V; Carbajal, E T; Vogel, D R; Aroca Martinez, G J; Garcia, L H; Cuevas, J H; Lara Teran, J; Hitzenberger, G; Leao Neves, P; Middlemost, S J; Dumortier, T; Bunt, A M; Smith, R D

    2000-01-01

    The efficacy and safety of losartan and valsartan were evaluated in a multicenter, double-blind, randomized trial in patients with mild to moderate essential hypertension. Blood pressure responses to once-daily treatment with either losartan 50 mg (n = 93) or valsartan 80 mg (n = 94) for 6 weeks were assessed through measurements taken in the clinic and by 24-hour ambulatory blood pressure monitoring (ABPM). Both drugs significantly reduced clinic sitting systolic (SiSBP) and diastolic blood pressure (SiDBP) at 2, 4, and 6 weeks. Maximum reductions from baseline in SiSBP and SiDBP on 24-hour ABPM were also significant with the two treatments. The reduction in blood pressure was more consistent across patients in the losartan group, as indicated by a numerically smaller variability in change from baseline on all ABPM measures, which achieved significance at peak (P = .017) and during the day (P = .002). In addition, the numerically larger smoothness index with losartan suggested a more homogeneous antihypertensive effect throughout the 24-hour dosing interval. The antihypertensive response rate was 54% with losartan and 46% with valsartan. Three days after discontinuation of therapy, SiDBP remained below baseline in 73% of losartan and 63% of valsartan patients. Both agents were generally well tolerated. Losartan, but not valsartan, significantly decreased serum uric acid an average 0.4 mg/dL at week 6. In conclusion, once-daily losartan 50 mg and valsartan 80 mg had similar antihypertensive effects in patients with mild to moderate essential hypertension. Losartan produced a more consistent blood pressure-lowering response and significantly lowered uric acid, suggesting potentially meaningful differences between these two A II receptor antagonists.

  18. Hypotension based on office and ambulatory monitoring blood pressure. Prevalence and clinical profile among a cohort of 70,997 treated hypertensives.

    PubMed

    Divisón-Garrote, Juan A; Banegas, José R; De la Cruz, Juan J; Escobar-Cervantes, Carlos; De la Sierra, Alejandro; Gorostidi, Manuel; Vinyoles, Ernest; Abellán-Aleman, José; Segura, Julián; Ruilope, Luis M

    2016-09-01

    We aimed to determine the prevalence of hypotension and factors associated with the presence of this condition in treated hypertensive patients undergoing ambulatory blood pressure monitoring (ABPM). Data were taken from the Spanish ABPM Registry. Office blood pressure (BP) and ABPM were determined using validated devices under standardized conditions. Based on previous studies, hypotension was defined as office systolic/diastolic BP <110 and/or 70 mm Hg, daytime ABPM <105 and/or 65 mm Hg, nighttime ABPM <90 and/or 50 mm Hg, and 24-hour ABPM <100 and/or 60 mm Hg. Multivariable logistic regression was performed to determine the variables associated with the presence of hypotension. A total of 70,997 hypertensive patients on treatment (mean age 61.8 years, 52.5% men) were included in the study. The prevalence of hypotension was 8.2% with office BP, 12.2% with daytime ABPM, 3.9% with nighttime ABPM, and 6.8% with 24-hour ABPM. Low diastolic BP values were responsible for the majority of cases of hypotension. Some 68% of the hypotension cases detected by daytime ABPM did not correspond to hypotension according to office BP. The variables independently and consistently associated with higher likelihood of office, daytime, and 24 hour-based hypotension were age, female gender, history of ischemic heart disease, and body mass index <30 kg/m(2) (P < .05). In conclusion, in this large cohort of patients in usual daily practice, one in eight treated hypertensive patients are at risk of hypotension according to daytime BP. Two-thirds of them are not adequately identified with office BP. ABPM could be especially helpful for identifying ambulatory hypotension, in particular in patients who are older, women, or with previous ischemic heart disease where antihypertensive treatment should be especially individualized and cautious.

  19. Monitoring your baby before labor

    MedlinePlus

    Prenatal care - monitoring; Pregnancy care - monitoring; Non-stress test - monitoring; NST- monitoring; Contraction stress test - monitoring; CST- monitoring; Biophysical profile - monitoring; BPP - monitoring

  20. Optimising calcium monitoring post thyroid and parathyroid surgery

    PubMed Central

    Rayner, Eleanor; Williams, Nerida; Dunn, Julie

    2014-01-01

    There is a risk of hypocalcaemia following total thyroidectomy and parathyroidectomy surgery, with the nadir being two to five days post operatively.[1] This project examined and improved the post-operative monitoring of serum calcium in patients undergoing these procedures at the Royal Devon and Exeter (RD&E) Hospital over a ten month period in 2013. A retrospective audit was undertaken, identifying whether serum calcium was monitored according to guideline; ie measured within the first 24 hours of surgery and daily thereafter until the patient was normocalcaemic.[2–3] The audit showed an overall compliance in 79% (n = 34) of cases. Of the non-compliant cases (n=9), seven also suffered hypocalcaemia. The current process was mapped by a flow chart and used as a basis for discussing experiences and identifying areas for improvement. Interventions implemented included a patient leaflet, a process flow chart displayed in the team office and in the weekend handover book, standard text for use in discharge summaries describing the process to GPs, the issuing of prescriptions or actual supplements for patients felt to be at high risk of hypocalcaemia, and finally education to the wider surgical junior doctor team. Percentage compliance with guidelines was compared before and after intervention with a re-audit undertaken in April 2014. Significant improvement was shown, with 100% of re-audit cases compliant (n=41), and all seven cases of hypocalcaemia were managed in full compliance with guideline. PMID:26732097

  1. Volcano monitoring using the Global Positioning System: Filtering strategies

    USGS Publications Warehouse

    Larson, K.M.; Cervelli, Peter; Lisowski, M.; Miklius, Asta; Segall, P.; Owen, S.

    2001-01-01

    Permanent Global Positioning System (GPS) networks are routinely used for producing improved orbits and monitoring secular tectonic deformation. For these applications, data are transferred to an analysis center each day and routinely processed in 24-hour segments. To use GPS for monitoring volcanic events, which may last only a few hours, real-time or near real-time data processing and subdaily position estimates are valuable. Strategies have been researched for obtaining station coordinates every 15 min using a Kalman filter; these strategies have been tested on data collected by a GPS network on Kilauea Volcano. Data from this network are tracked continuously, recorded every 30 s, and telemetered hourly to the Hawaiian Volcano Observatory. A white noise model is heavily impacted by data outages and poor satellite geometry, but a properly constrained random walk model fits the data well. Using a borehole tiltmeter at Kilauea's summit as ground-truth, solutions using different random walk constraints were compared. This study indicates that signals on the order of 5 mm/h are resolvable using a random walk standard deviation of 0.45 cm/???h. Values lower than this suppress small signals, and values greater than this have significantly higher noise at periods of 1-6 hours. Copyright 2001 by the American Geophysical Union.

  2. Evaluation of Commercial Self-Monitoring Devices for Clinical Purposes: Results from the Future Patient Trial, Phase I

    PubMed Central

    Leth, Soren; Hansen, John; Nielsen, Olav W.; Dinesen, Birthe

    2017-01-01

    Commercial self-monitoring devices are becoming increasingly popular, and over the last decade, the use of self-monitoring technology has spread widely in both consumer and medical markets. The purpose of this study was to evaluate five commercially available self-monitoring devices for further testing in clinical applications. Four activity trackers and one sleep tracker were evaluated based on step count validity and heart rate validity. Methods: The study enrolled 22 healthy volunteers in a walking test. Volunteers walked a 100 m track at 2 km/h and 3.5 km/h. Steps were measured by four activity trackers and compared to gyroscope readings. Two trackers were also tested on nine subjects by comparing pulse readings to Holter monitoring. Results: The lowest average systematic error in the walking tests was −0.2%, recorded on the Garmin Vivofit 2 at 3.5 km/h; the highest error was the Fitbit Charge HR at 2 km/h with an error margin of 26.8%. Comparisons of pulse measurements from the Fitbit Charge HR revealed a margin error of −3.42% ± 7.99% compared to the electrocardiogram. The Beddit sleep tracker measured a systematic error of −3.27% ± 4.60%. Conclusion: The measured results revealed the current functionality and limitations of the five self-tracking devices, and point towards a need for future research in this area. PMID:28117736

  3. Ion Monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2003-11-18

    The apparatus and method provide a technique for significantly reducing capacitance effects in detector electrodes arising due to movement of the instrument relative to the item/location being monitored in ion detection based techniques. The capacitance variations are rendered less significant by placing an electrically conducting element between the detector electrodes and the monitored location/item. Improved sensitivity and reduced noise signals arise as a result. The technique also provides apparatus and method suitable for monitoring elongate items which are unsuited to complete enclosure in one go within a chamber. The items are monitored part by part as the pass through the instrument, so increasing the range of items or locations which can be successfully monitored.

  4. Real-time noninvasive optoacoustic monitoring of nanoparticle-mediated photothermal therapy of tumors

    NASA Astrophysics Data System (ADS)

    Esenaliev, R. O.; Petrov, Y. Y.; Cicenaite, I.; Chumakova, O. V.; Petrova, I. Y.; Patrikeev, I.; Liopo, A.

    2007-02-01

    We proposed and have been developing real-time, noninvasive monitoring of blood oxygenation, total hemoglobin concentration, and thermotherapy including hyperthermia, coagulation, and cryotherapy. In this paper we propose to use the optoacoustic technique for monitoring of nanoparticle-mediated photothermal therapy (NPT) of tumors. NPT is based on heating exogenous strongly-absorbing nanoparticles selectively delivered in tumors. Real-time monitoring of NPT is necessary for precise tumor therapy with minimal damage to normal tissues. In this study we injected PEGylated and non-PEGylated carbon nanoparticles in nude mice bearing human tumors (5-15 mm) and irradiated the tumors for 10 minutes with nanosecond Nd:YAG laser pulses which produced both thermal damage to the tumors and optoacoustic signals for monitoring NPT in real time. Irradiation of tumors was performed during or after (3 or 24 hours) nanoparticle injection. Amplitude and temporal parameters of optoacoustic signals (measured with a custom-made wide-band optoacoustic probe) correlated well with nanoparticle injection, temperature rise in tumors, and tumor coagulation. Substantial thermal damage in large areas of the tumors was produced when optimal irradiation parameters were used. Monte Carlo modeling of light distribution in tumors and optoacoustic theory were applied to study kinetics of nanoparticle concentration in the tumors. Our results demonstrated that the optoacoustic technique can be used for real-time monitoring of NTP and provide precise tumor therapy with minimal damage to normal tissues.

  5. Monitoring and detecting atrial fibrillation using wearable technology.

    PubMed

    Nemati, Shamim; Ghassemi, Mohammad M; Ambai, Vaidehi; Isakadze, Nino; Levantsevych, Oleksiy; Shah, Amit; Clifford, Gari D

    2016-08-01

    Atrial fibrillation (AFib) is diagnosed by analysis of the morphological and rhythmic properties of the electrocardiogram. It was recently shown that accurate detection of AFib is possible using beat-to-beat interval variations. This raises the question of whether AFib detection can be performed using a pulsatile waveform such as the Photoplethysmogram (PPG). The recent explosion in use of recreational and professional ambulatory wrist-based pulse monitoring devices means that an accurate pulse-based AFib screening algorithm would enable large scale screening for silent or undiagnosed AFib, a significant risk factor for multiple diseases. We propose a noise-resistant machine learning approach to detecting AFib from noisy ambulatory PPG recorded from the wrist using a modern research watch-based wearable device (the Samsung Simband). Ambulatory pulsatile and movement data were recorded from 46 subjects, 15 with AFib and 31 non symptomatic. Single channel electrocardiogram (ECG), multi-wavelength PPG and tri-axial accelerometry were recorded simultaneously at 128 Hz from the non-dominant wrist using the Simband. Recording lengths varied from 3.5 to 8.5 minutes. Pulse (beat) detection was performed on the PPG waveforms, and eleven features were extracted based on beat-to-beat variability and waveform signal quality. Using 10-fold cross validation, an accuracy of 95 % on out-of-sample data was achieved, with a sensitivity of 97%, specificity of 94%, and an area under the receiver operating curve (AUROC) of 0.99. The described approach provides a noise-resistant, accurate screening tool for AFib from PPG sensors located in an ambulatory wrist watch. To our knowledge this is the first study to demonstrate an algorithm with a high enough accuracy to be used in general population studies that does not require an ambulatory Holter electrocardiographic monitor.

  6. Lack of correlation between extended pH monitoring and scintigraphy in the evaluation of infants with gastroesophageal reflux

    SciTech Connect

    Tolia, V.; Calhoun, J.A.; Kuhns, L.R.; Kauffman, R.E. )

    1990-05-01

    Sixty-nine infants younger than 1 year of age, with symptoms of persistent vomiting, recurrent choking, apnea, persistent cough, or stridor, were evaluated for gastroesophageal reflux. All infants underwent extended intraesophageal pH monitoring for 16 to 24 hours as well as gastroesophageal scintigraphy with technetium 99m sulfur colloid to study the correlation between the two tests. Forty-eight infants exhibited reflux with extended pH monitoring whereas 46 infants showed reflux with scintigraphy. However, the diagnosis of reflux in individual patients by extended pH monitoring corresponded poorly with the diagnosis of reflux in the same patients by scintigraphy. Similarly, no correlation was observed between extended pH monitoring and scintigraphy results, whether expressed as percent gastric emptying or as gastroesophageal reflux ratio. We conclude that extended pH monitoring and scintigraphy measure different pathophysiologic phenomena and detect reflux under different conditions. The ability of these tests to detect reflux may be complementary and they may be of greatest value when used together to enhance the sensitivity and specificity of the diagnostic evaluation. Extended pH monitoring and scintigraphy should not be used interchangeably to monitor gastroesophageal reflux.

  7. Electrostatic monitoring

    DOEpatents

    Orr, Christopher Henry; Luff, Craig Janson; Dockray, Thomas; Macarthur, Duncan Whittemore

    2001-01-01

    The apparatus and method provide a technique for more simply measuring alpha and/or beta emissions arising from items or locations. The technique uses indirect monitoring of the emissions by detecting ions generated by the emissions, the ions being attracted electrostatically to electrodes for discharge of collection. The apparatus and method employ a chamber which is sealed around the item or location during monitoring with no air being drawn into or expelled from the chamber during the monitoring process. A simplified structure and operations arises as a result, but without impairing the efficiency and accuracy of the detection technique.

  8. Biological monitoring

    SciTech Connect

    Ho, M.H.; Dillon, H.K.

    1986-02-01

    Biological monitoring is defined as the measurement and assessment of workplace agents or their metabolites in tissues, secreta, excreta, expired air, or any combination of these to evaluate exposure and health risk compared to an appropriate reference. Biological monitoring offers several advantages: it takes into account individual variability in biological activity resulting from a chemical insult. It takes into account the effects of personal physical activity and individual life styles. It is a valuable adjunct to ambient monitoring and health surveillance. The importance of chemical speciation in the toxicity of pollutants is discussed. Basic protocols for lead, aluminum, cadmium, mercury, selenium, and nickel are presented. Basic criteria for biological monitoring methods are presented. 11 references, 1 table.

  9. Environment Monitor

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Viking landers touched down on Mars equipped with a variety of systems to conduct automated research, each carrying a compact but highly sophisticated instrument for analyzing Martian soil and atmosphere. Instrument called a Gas Chromatography/Mass Spectrometer (GC/MS) had to be small, lightweight, shock resistant, highly automated and extremely sensitive, yet require minimal electrical power. Viking Instruments Corporation commercialized this technology and targeted their primary market as environmental monitoring, especially toxic and hazardous waste site monitoring. Waste sites often contain chemicals in complex mixtures, and the conventional method of site characterization, taking samples on-site and sending them to a laboratory for analysis is time consuming and expensive. Other terrestrial applications are explosive detection in airports, drug detection, industrial air monitoring, medical metabolic monitoring and for military, chemical warfare agents.

  10. 50 CFR 217.205 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-713-2289), within 24 hours of the discovery of the injured or dead animal. (b) The Holder of a Letters... sighting, tidal stage, and weather conditions (including Beaufort Sea State); (ii) Species, number,...

  11. Sitcom syncope: a case series and literature review of gelastic (laughter-induced) syncope.

    PubMed

    Thiagarajah, Prashan H; Finkielstein, Dennis; Granato, Jerome E

    2010-11-01

    Syncope is a common complaint that is frequently evaluated without identifying a precipitating cause. Gelastic (laughter-induced) syncope is an uncommon and poorly understood condition. We describe 3 patients who experienced loss of consciousness during vigorous laughter. Each patient had an extensive medical evaluation, including a comprehensive history and physical examination, 12-lead electrocardiography, chest radiograph, routine blood analysis, polysomnography, tilt table testing, 2-dimensional transthoracic echocardiography, nuclear or echocardiographic stress testing, and 24-hour Holter monitoring. All 3 patients had an abnormal response to head-up tilt table testing, with either a significant decrease in systolic blood pressure or inappropriate heart rate response on achieving an upright position. These observations together with our review of the literature suggest that gelastic syncope may be a variant of vasodepressor syncope. Knowledge of this condition, its pathophysiology, and potential treatment options may be of value to clinicians when evaluating patients with unexplained loss of consciousness.

  12. Salt Intakes, Knowledge, and Behavior in Samoa: Monitoring Salt-Consumption Patterns Through the World Health Organization's Surveillance of Noncommunicable Disease Risk Factors (STEPS).

    PubMed

    Webster, Jacqui; Su'a, Sarah Asi Faletoese; Ieremia, Merina; Bompoint, Severine; Johnson, Claire; Faeamani, Gavin; Vaiaso, Miraneta; Snowdon, Wendy; Land, Mary-Anne; Trieu, Kathy; Viali, Satu; Moodie, Marj; Bell, Colin; Neal, Bruce; Woodward, Mark

    2016-09-01

    This project measured population salt intake in Samoa by integrating urinary sodium analysis into the World Health Organization's (WHO's) STEPwise approach to surveillance of noncommunicable disease risk factors (STEPS). A subsample of the Samoan Ministry of Health's 2013 STEPS Survey collected 24-hour and spot urine samples and completed questions on salt-related behaviors. Complete urine samples were available for 293 participants. Overall, weighted mean population 24-hour urine excretion of salt was 7.09 g (standard error 0.19) to 7.63 g (standard error 0.27) for men and 6.39 g (standard error 0.14) for women (P=.0014). Salt intake increased with body mass index (P=.0004), and people who added salt at the table had 1.5 g higher salt intakes than those who did not add salt (P=.0422). A total of 70% of the population had urinary excretion values above the 5 g/d cutoff recommended by the WHO. A reduction of 30% (2 g) would reduce average population salt intake to 5 g/d, in line with WHO recommendations. While challenging, integration of salt monitoring into STEPS provides clear logistical and cost benefits and the lessons communicated here can help inform future programs.

  13. Prevalence of left ventricular hypertrophy in hypertensive patients without and with blood pressure control: data from the PAMELA population. Pressioni Arteriose Monitorate E Loro Associazioni.

    PubMed

    Mancia, Giuseppe; Carugo, Stefano; Grassi, Guido; Lanzarotti, Arturo; Schiavina, Riccardo; Cesana, Giancarlo; Sega, Roberto

    2002-03-01

    Previous studies have shown that in the population, only a minority of treated hypertensive patients achieve blood pressure (BP) control. Whether and to what extent this inadequate control has reflection on hypertension-related organ damage has never been systematically examined. In 2051 subjects belonging to the PAMELA (Pressioni Arteriose Monitorate E Loro Associazioni) Study population, we measured office, home, and 24-hour ambulatory BP values, together with echocardiographic left ventricular mass and wall thickness. Based on the fraction on antihypertensive treatment and on measurements of increased or normal office, home, or 24-hour ambulatory BP values, subjects were classified as normotensives, untreated hypertensives, treated hypertensives with inadequate BP control, and treated hypertensives with effective BP control. Compared with values in the normotensive group, left ventricular mass index, left ventricular wall thickness, and prevalence of left ventricular hypertrophy were markedly increased not only in untreated hypertensive patients but also in treated hypertensives with inadequate BP control. Echocardiographic abnormalities were less in treated hypertensives with BP control than in patients with inadequate BP control, but values were still clearly greater than in normotensive subjects. This was the case regardless whether BP control was assessed by office, home, and/or ambulatory values. Our data provide evidence that in the hypertensive fraction of the population, cardiac structural alterations can be frequently found in both the presence and absence of antihypertensive treatment. They also imply that even effective treatment of hypertension does not allow complete reversal of the cardiac organ damage characterizing high BP states.

  14. Dietary assessment and self-monitoring with nutrition applications for mobile devices.

    PubMed

    Lieffers, Jessica R L; Hanning, Rhona M

    2012-01-01

    Nutrition applications for mobile devices (e.g., personal digital assistants, smartphones) are becoming increasingly accessible and can assist with the difficult task of intake recording for dietary assessment and self-monitoring. This review is a compilation and discussion of research on this tool for dietary intake documentation in healthy populations and those trying to lose weight. The purpose is to compare this tool with conventional methods (e.g., 24-hour recall interviews, paper-based food records). Research databases were searched from January 2000 to April 2011, with the following criteria: healthy or weight loss populations, use of a mobile device nutrition application, and inclusion of at least one of three measures, which were the ability to capture dietary intake in comparison with conventional methods, dietary self-monitoring adherence, and changes in anthropometrics and/or dietary intake. Eighteen studies are discussed. Two application categories were identified: those with which users select food and portion size from databases and those with which users photograph their food. Overall, positive feedback was reported with applications. Both application types had moderate to good correlations for assessing energy and nutrient intakes in comparison with conventional methods. For self-monitoring, applications versus conventional techniques (often paper records) frequently resulted in better self-monitoring adherence, and changes in dietary intake and/or anthropometrics. Nutrition applications for mobile devices have an exciting potential for use in dietetic practice.

  15. COLD MAGICS - Continuous Local Deformation Monitoring of an Arctic Geodetic Fundamental Station

    NASA Technical Reports Server (NTRS)

    Haas, Ruediger; Bergstrand, Sten

    2010-01-01

    We describe the experience gained in a project to continuously monitor the local tie at the Geodetic Observatory Ny-Alesund. A PC-controlled robotic total station was used to monitor survey prisms that were attached to survey pillars of the local network and the monuments used for geodetic VLBI and GNSS measurements. The monitoring lasted for seven days and had a temporal resolution of six minutes. The raw angle and distance measurements show clear sinusoidal signatures with a daily period, most strongly for a four-day period with 24 hours of sunshine. The derived topocentric coordinates of the survey prisms attached to the GNSS monument and the VLBI radio telescope act as approximation for the local tie. We detect clear signatures at the mm-level. With the current approach we cannot distinguish between real motion of the prisms and potential thermal influences on the instrument used for the observations. However, the project shows that continuous local tie monitoring is feasible today and in the future can and should be used for all geodetic co-location stations.

  16. Utility of Duranta, a wireless patch-type electrocardiographic monitoring system developed in Japan, in detecting covert atrial fibrillation in patients with cryptogenic stroke

    PubMed Central

    Akiyama, Hisanao; Nukui, Saki; Araga, Takashi; Hoshino, Masashi; Tanaka, Keita; Kashima, Satoru; Sasaki, Rie; Uchino, Kenji; Hasegawa, Yasuhiro

    2017-01-01

    Abstract Rationale: Subcutaneous implantable electrocardiographs are highly effective in detecting covert atrial fibrillation (AF) in cryptogenic stroke. However, these invasive devices are not indicated for all cryptogenic stroke patients, and noninvasive improvements over conventional Holter-type ambulatory electrocardiography are needed. We evaluated the clinical application and effectiveness of Duranta (ImageONE Co., Ltd.), a wireless patch-type electrocardiographic monitoring system developed in Japan for chronically ill patients or home-based patients at the end of life. A Duranta device was used to detect covert AF in patients with acute ischemic stroke of undetermined source with no sign of AF during cardiographic monitoring ≥24 hours postadmission. Patient concerns: A 72-year-old man with severe aortic stenosis was admitted to our hospital with dysarthria and right upper limb weakness. Diffusion-weighted plain head magnetic resonance imaging (MRI) showed acute cerebral infarctions across the left middle cerebral artery territory. Twelve-lead electrocardiography, Holter-type ambulatory electrocardiography, and cardiographic monitoring for ≥24 hours revealed no AF, indicating a probable diagnosis of artery-to-artery embolism following left common carotid artery stenosis detected by carotid ultrasound imaging and cerebral angiography. Interventions: However, because of high blood brain natriuretic peptide (BNP) and valvular heart disease, continuous monitoring using Duranta was performed from the 2nd to 13th days after onset to exclude possible cardioembolic stroke. Waveform and heart rate trend graph analysis showed paroxysmal AF (PAF) occurred on the 5th and 9th days after onset. PAF did not occur at any other time during the observation period. The quality of the cardiograms sufficed for analysis and diagnosis of AF. The lightweight compact device can be placed quickly with no movement restriction. These features and our findings show the

  17. Noninvasive Cardiac Screening in Young Athletes With Ventricular Arrhythmias

    PubMed Central

    Steriotis, Alexandros Klavdios; Nava, Andrea; Rigato, Ilaria; Mazzotti, Elisa; Daliento, Luciano; Thiene, Gaetano; Basso, Cristina; Corrado, Domenico; Bauce, Barbara

    2013-01-01

    The aim of this study was to analyze using noninvasive cardiac examinations a series of young athletes discovered to have ventricular arrhythmias (VAs) during the preparticipation screening program for competitive sports. One hundred forty-five athletes (mean age 17 ± 5 years) were evaluated. The study protocol included electrocardiography (ECG), exercise testing, 2-dimensional and Doppler echocardiography, 24-hour Holter monitoring, signal-averaged ECG, and in selected cases contrast-enhanced cardiac magnetic resonance imaging. Results of ECG were normal in most athletes (85%). VAs were initially detected prevalently during exercise testing (85%) and in the remaining cases on ECG and Holter monitoring. Premature ventricular complexes disappeared during exercise in 56% of subjects. Premature ventricular complexes during Holter monitoring averaged 4,700 per day, predominantly monomorphic (88%), single, and/or in couplets (79%). The most important echocardiographic findings were mitral valve prolapse in 29 patients (20%), congenital heart disease in 4 (3%), and right ventricular regional kinetic abnormalities in 5 (3.5%). On cardiac magnetic resonance imaging, right ventricular regional kinetic abnormalities were detected in 9 of 30 athletes and were diagnostic of arrhythmogenic right ventricular cardiomyopathy in only 1 athlete. Overall, 30% of athletes were judged to have potentially dangerous VAs. In asymptomatic athletes with prevalently normal ECG, most VAs can be identified by adding an exercise test during preparticipation screening. In conclusion, cardiac screening with noninvasive examinations remains a fundamental tool for the identification of a possible pathologic substrate and for the characterization of electrical instability. PMID:23219000

  18. [Late ventricular potentials and mitral valve prolapse].

    PubMed

    Babuty, D; Charniot, J C; Delhomme, C; Fauchier, L; Fauchier, J P; Cosnay, P

    1994-03-01

    In order to determine the predictive value for ventricular arrhythmias of ventricular late potentials (LP) in mitral valve prolapse (MVP) the authors performed high amplification signal-averaging ECG (SA) and 24 hours ambulatory ECG (Holter) monitoring in 68 consecutive patients (34 men, 34 women, average age 48 +/- 17.7 years) with echocardiographically diagnosed MVP. Patients with bundle branch block or associated cardiac disease were excluded. Echocardiography showed 26 patients to have floppy mitral valves (38.2%), 50 patients to have posterior deplacement > or = 5 mm of the mitral valves in systole (73.5%) and 35 patients to have mitral regurgitation (51.4%). Holter monitoring showed 17 patients without ventricular extrasystoles (VES), 15 had Lown Grade I, 6 had Lown Grade II, 3 had Lown Grade III, 15 had Lown Grade IV A and 12 had Lown Grade IV B ventricular arrhythmias. Therefore, 30 patients had complex ventricular arrhythmias (> or = Lown Grade III) and 13 patients had spontaneous non-sustained ventricular tachycardia (NSVT) (one patient had NSVT on resting ECG but not on Holter monitoring). Eighteen patients had LP (26.5%). The incidence of complex ventricular arrhythmias was higher in patients with mitral regurgitation (62.8% versus 27.7%; p < 0.005) whereas the incidence of NSVT was not significantly different (25.7% versus 17.1%; p = 0.15). On the other hand, the frequency of complex ventricular arrhythmias was not significantly different in the presence or absence of LP (61.1% versus 40%: NS) whereas the incidence of NSVT was higher in patients with LP (44.4% versus 10%; p < 0.005).(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Recreation monitoring

    SciTech Connect

    DiGennaro, B.; Merklein, G.H.

    1995-12-31

    Recreational use and recreational facilities are common features at hydropower projects. In fact, the hydropower industry is a major supplier of recreational opportunities contributing to tourism and rural economic growth in many communities across the country, As demands for public recreation have grown, pressure on the hydropower industry to provide more public access and more facilities has increased. This paper looks at recent developments in the FERC licensing and compliance arenas with regard to planning for and monitoring recreation at hydropower facilities. The paper highlights the increased occurrence of recreation monitoring requirements in license articles and discusses methods for complying with such requirements. The paper also looks at how monitoring data can be used to avoid unnecessary developments and to better plan for future recreation use.

  20. Monitoring technology

    NASA Technical Reports Server (NTRS)

    Stevenson, William A. (Inventor)

    1989-01-01

    A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

  1. Monitoring technology

    NASA Technical Reports Server (NTRS)

    Stevenson, William A. (Inventor)

    1992-01-01

    A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

  2. Monitoring well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2002-01-01

    The present invention relates to a monitoring well which includes an enclosure defining a cavity and a water reservoir enclosed within the cavity and wherein the reservoir has an inlet and an outlet. The monitoring well further includes a porous housing borne by the enclosure and which defines a fluid chamber which is oriented in fluid communication with the outlet of the reservoir, and wherein the porous housing is positioned in an earthen soil location below-grade. A geophysical monitoring device is provided and mounted in sensing relation relative to the fluid chamber of the porous housing; and a coupler is selectively moveable relative to the outlet of reservoir to couple the porous housing and water reservoir in fluid communication. An actuator is coupled in force transmitting relation relative to the coupler to selectively position the coupler in a location to allow fluid communication between the reservoir and the fluid chamber defined by the porous housing.

  3. COMPARATIVE EVALUATION OF AMBIENT FINE PARTICULATE MATTER (PM2.5) DATA OBTAINED FROM URBAN AND RURAL MONITORING SITES ALONG THE UPPER OHIO RIVER VALLEY

    SciTech Connect

    Robinson P. Khosah; John P. Shimshock; Jerry L. Penland

    2004-10-15

    Advanced Technology Systems, Inc. (ATS), with Desert Research Institute (DRI) and Ohio University as subcontractors, was contracted by the NETL in September 1998 to manage the Upper Ohio River Valley Project (UORVP), which included the establishment and operation of four ambient air monitoring sites located in the Upper Ohio River Valley (UORV). Two urban and two rural monitoring sites were included in the UORVP. The four sites selected for the UOVRP were collocated at existing local and/or state air quality monitoring stations. The goal of the UORVP was to characterize the nature and composition of PM{sub 2.5} and its precursor gases. In the process, the objectives of the UORVP were to examine the ambient air concentrations of PM{sub 2.5} as compared with the promulgated PM{sub 2.5} standards, the geographical, seasonal and temporal variations of ambient air concentrations of PM{sub 2.5}, the primary chemical constituents of PM{sub 2.5}, and the correlations between ambient air concentrations of PM{sub 2.5} and its precursor gases, other gaseous pollutants and meteorological parameters. A variety of meteorological and pollutant measurement devices, including several different PM{sub 2.5} samplers that provided either real-time or integrated concentration data, were deployed at the monitoring sites. The frequency of integrated sampling varied throughout the UORVP study period and was as follows: ''Intensive'' sampling periods were defined as periods in which samples were collected on a relatively frequent basis (ranged from 6-hour integrated samples collected round-the-clock to one 24-hour integrated sample collected every third day). ''Background'' sampling periods were defined as periods in which 24-hour integrated samples were collected every third or sixth day.

  4. Monitoring driver's sleepiness on-board for preventing road accidents.

    PubMed

    Papadelis, Christos; Lithari, Chrysa; Kourtidou-Papadeli, Chrysoula; Bamidis, Panagiotis D; Portouli, Evangelia; Bekiaris, Evangelos

    2009-01-01

    Driver sleepiness due to sleep deprivation is a causative factor of many road accidents. Reducing the extent of the sleepy driving problem by developing a countermeasure device that will monitor the sleepiness level of the driver is crucial to improve the safety of the roads. Among numerous physiological measurements, the electroencephalographic (EEG) signal seems to be the most sensitive to detect sleepiness. Previous studies in the field have found consistent alterations of EEG signal during sleepy driving, though they face methodological limitations. We present here preliminary results from a real-driving experiment in which a more complete experimental setup was followed. The subjects were exposed to driving conditions twice: once after they had a normal sleep during the previous night, and once after they remained awake for at least 24 hours prior to the experiment. Significant alterations were observed in the alpha and beta EEG frequencies bands between the two sessions. Electroopthalmographic (EOG) measurements revealed an increased number of eye blinking during the sleep-deprived session in comparison to the control condition. Both measurements can be used for the successful design of a sleepiness detection countermeasure device.

  5. LESSONS LEARNED IN AEROSOL MONITORING WITH THE RASA

    SciTech Connect

    Forrester, Joel B.; Bowyer, Ted W.; Carty, Fitz; Comes, Laura; Eslinger, Paul W.; Greenwood, Lawrence R.; Haas, Derek A.; Hayes, James C.; Kirkham, Randy R.; Lepel, Elwood A.; Litke, Kevin E.; Miley, Harry S.; Morris, Scott J.; Schrom, Brian T.; Van Davelaar, Peter; Woods, Vincent T.

    2011-09-14

    The Radionuclide Aerosol Sampler/Analyzer (RASA) is an automated aerosol collection and analysis system designed by Pacific Northwest National Laboratory (PNNL) in the 1990's and is deployed in several locations around the world as part of the International Monitoring System (IMS) required under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The RASA operates unattended, save for regularly scheduled maintenance, iterating samples through a three-step process on a 24-hour interval. In its 15-year history, much has been learned from the operation and maintenance of the RASA that can benefit engineering updates or future aerosol systems. On 11 March 2011, a 9.0 magnitude earthquake and tsunami rocked the eastern coast of Japan, resulting in power loss and cooling failures at the Daiichi nuclear power plants in Fukushima Prefecture. Aerosol collections were conducted with the RASA in Richland, WA. We present a summary of the lessons learned over the history of the RASA, including lessons taken from the Fukushima incident, regarding the RASA IMS stations operated by the United States.

  6. Noninvasive monitoring of salmonella infections in young mice

    NASA Astrophysics Data System (ADS)

    Olomu, Isoken N.; Reilly-Contag, Pamela; Stevenson, David K.; Contag, Christopher H.

    1999-07-01

    A recently developed bioluminescent assay was used to study the influence of age and inoculum size on the acute susceptibility of newborn and juvenile BALB/c mice to Salmonella gastrointestinal infection. Three strains of Salmonella were tagged by expression of the lux operon from Photohabdus luminescenes. Using a range of inoculum sizes varied over 6 orders of magnitude, mice aged 0-6 weeks were infected by oral inoculation. LIght emitted from the tagged bacteria and transmitted through mouse tissues was used to noninvasively monitor disease progression over 7 days. In neonatal mice there was evidence of gastrointestinal infection at 24 hours even with small inocular, and at 4-7 days, the patterns of photon emission and remained and healthy throughout the study period. Inoculation of neonates with tagged LB5000 and BJ66 resulted in severe gastrointestinal infections with low and intermediate sizes of inocula respectively. These strains are known to be of reduced virulence in adult mice. These age-related differences in susceptibility emphasize the need to define virulence in the context of age of the host, and implicate maturation of innate resistance factors in determining disease patterns. Identifying these host-factors and further defining the bacterial determinants of virulence in the neonatal host will be facilitated by this noninvasive study of infection using bioluminenscent methods.

  7. Amiodarone prophylaxis for tachycardias after coronary artery surgery: a randomised, double blind, placebo controlled trial.

    PubMed Central

    Butler, J; Harriss, D R; Sinclair, M; Westaby, S

    1993-01-01

    BACKGROUND--Arrhythmias are a common cause of morbidity after cardiac surgery. This study assessed the efficacy of prophylactic amiodarone in reducing the incidence of atrial fibrillation or flutter and ventricular arrhythmias after coronary artery surgery. METHODS--A double blind, randomised, placebo controlled trial. 60 patients received a 24 hour intravenous infusion of amiodarone (15 mg/kg started after removal of the aortic cross clamp) followed by 200 mg orally three times daily for 5 days, and 60 patients received placebo. RESULTS--6 patients (10%) in the amiodarone group and 14 (23%) in the placebo group needed treatment for arrhythmias (95% confidence interval (95% CI) for the difference between groups was 0 to 26%, p = 0.05). The incidence of supraventricular tachycardia detected clinically and requiring treatment was lower in the amiodarone group (8% amiodarone v 20% placebo, 95% CI 0 to 24%, p = 0.07). The incidence detected by 24 hour Holter monitoring was similar (17% amiodarone v 20% placebo). Untreated arrhythmias in the amiodarone group were either clinically benign and undetected (n = 3) or the ventricular response rate was slow (n = 2). Age > 60 years was a positive risk factor for the development of supraventricular tachycardia in the amiodarone group but not in the placebo group. Fewer patients had episodes of ventricular tachycardia or fibrillation recorded on Holter monitoring in the amiodarone group (15% amiodarone v 33% placebo, 95% CI 3 to 33%, p = 0.02). Bradycardia (78% amiodarone v 48% placebo, 95% CI 14% to 46%, p < 0.005) and pauses (7% amiodarone v 0% placebo) occurred in more amiodarone treated patients. Bradycardia warranted discontinuation of treatment in one patient treated with amiodarone. CONCLUSIONS--The incidence of clinically significant tachycardia was reduced by amiodarone. The ventricular response rate was slowed in supraventricular tachycardia, but the induction of bradycardia may preclude the routine use of amiodarone

  8. Parental Monitoring

    ERIC Educational Resources Information Center

    Shillington, Audrey M.; Lehman, Stephanie; Clapp, John; Hovell, Melbourne; Sipan, Carol; Blumberg, Elaine

    2005-01-01

    Adolescence is a developmental period during which many youth experiment with risk practices. This paper examined the association of parental monitoring with a range of alcohol and other drug (AOD) use behaviors among high-risk youth, while controlling for other demographic and environmental variables previously found to be associated with AOD…

  9. Monitoring well

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    1999-01-01

    A monitoring well including a conduit defining a passageway, the conduit having a proximal and opposite, distal end; a coupler connected in fluid flowing relationship with the passageway; and a porous housing borne by the coupler and connected in fluid flowing relation thereto.

  10. Monitoring airborne molecular contamination: a quantitative and qualitative comparison of real-time and grab-sampling techniques

    NASA Astrophysics Data System (ADS)

    Shupp, Aaron M.; Rodier, Dan; Rowley, Steven

    2007-03-01

    Monitoring and controlling Airborne Molecular Contamination (AMC) has become essential in deep ultraviolet (DUV) photolithography for both optimizing yields and protecting tool optics. A variety of technologies have been employed for both real-time and grab-sample monitoring. Real-time monitoring has the advantage of quickly identifying "spikes" and upset conditions, while 2 - 24 hour plus grab sampling allows for extremely low detection limits by concentrating the mass of the target contaminant over a period of time. Employing a combination of both monitoring techniques affords the highest degree of control, lowest detection limits, and the most detailed data possible in terms of speciation. As happens with many technologies, there can be concern regarding the accuracy and agreement between real-time and grab-sample methods. This study utilizes side by side comparisons of two different real-time monitors operating in parallel with both liquid impingers and dry sorbent tubes to measure NIST traceable gas standards as well as real world samples. By measuring in parallel, a truly valid comparison is made between methods while verifying the results against a certified standard. The final outcome for this investigation is that a dry sorbent tube grab-sample technique produced results that agreed in terms of accuracy with NIST traceable standards as well as the two real-time techniques Ion Mobility Spectrometry (IMS) and Pulsed Fluorescence Detection (PFD) while a traditional liquid impinger technique showed discrepancies.

  11. Post-encoding emotional arousal enhances consolidation of item memory, but not reality-monitoring source memory.

    PubMed

    Wang, Bo; Sun, Bukuan

    2017-03-01

    The current study examined whether the effect of post-encoding emotional arousal on item memory extends to reality-monitoring source memory and, if so, whether the effect depends on emotionality of learning stimuli and testing format. In Experiment 1, participants encoded neutral words and imagined or viewed their corresponding object pictures. Then they watched a neutral, positive, or negative video. The 24-hour delayed test showed that emotional arousal had little effect on both item memory and reality-monitoring source memory. Experiment 2 was similar except that participants encoded neutral, positive, and negative words and imagined or viewed their corresponding object pictures. The results showed that positive and negative emotional arousal induced after encoding enhanced consolidation of item memory, but not reality-monitoring source memory, regardless of emotionality of learning stimuli. Experiment 3, identical to Experiment 2 except that participants were tested only on source memory for all the encoded items, still showed that post-encoding emotional arousal had little effect on consolidation of reality-monitoring source memory. Taken together, regardless of emotionality of learning stimuli and regardless of testing format of source memory (conjunction test vs. independent test), the facilitatory effect of post-encoding emotional arousal on item memory does not generalize to reality-monitoring source memory.

  12. Comparison of the efficiencies of esophageal manometry, vector volume analysis and esophagus pH monitoring in the diagnosis of gastroesophageal reflux

    PubMed Central

    Aydın, Emrah; Özcan, Rahşan; Erdoğan, Ergun; Tekant, Gonca

    2015-01-01

    Aim: In this study, we aimed to compare the superiorities of esophageal manometry, vector volume analysis and 24-hour pH meter studies in showing gastroesophageal reflux disease. Material and Methods: The files of the patients who presented to pediatric surgery and pediatric gastroenterology outpatient clinics of our hospital with suspicious gastroesophageal reflux disease between 2011 and 2012 and who were investigated were examined and 21 patients whose investigations had been completed were included in the study. The patients were evaluated by treatment method and were divided into three groups as Group 1 who were followed up with medical treatment, Group 2 in whom surgical intervention was performed and Group 3 who were not treated. Chi-square test was used in evaluation of the categorical variables, Kruskal Wallis test was used in comparison of the mean values between the groups and Dunn test was used in subgroup analyses when Kruskal Wallis test was found to be significant. A p value of <0.05 was considered statistically significant. Results: Thirteen of 21 patients included in the study were female and eight were male. The mean age of the patients was 5.71 years (one-16 years). In the 24-hour pH monitoring study, the mean reflux index was found to be 48.7% in Group 1, 42.4% in Group 2 and 28.3% in Group 3. In esophageal manometry studies, the pressure difference at lower esophageal sphincter (LES) was found to be 13,4 cm H2O in Group 1, 31.8 cm H2O in Group 2 and 4.3 cmH2O in Group 3. In vector volume analyses, the mean vector volume was calculated to be 96.01 cm3 in Group 1, 2 398.9 cm3 in Group 2 and 196.3 cm3 in Group 3. In the 24-hour pH monitoring study, a statistically significant difference (p<0.05) was found in terms of showing reflux, whereas statistical significance could not be shown in terms of need for surgical treatment or need for medical treatment in any other method (p>0.05). Conclusions: Twenty-four-hour pH monitoring was found to be

  13. Sewage Monitors

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Every U.S. municipality must determine how much waste water it is processing and more importantly, how much is going unprocessed into lakes and streams either because of leaks in the sewer system or because the city's sewage facilities were getting more sewer flow than they were designed to handle. ADS Environmental Services, Inc.'s development of the Quadrascan Flow Monitoring System met the need for an accurate method of data collection. The system consists of a series of monitoring sensors and microcomputers that continually measure water depth at particular sewer locations and report their findings to a central computer. This provides precise information to city managers on overall flow, flow in any section of the city, location and severity of leaks and warnings of potential overload. The core technology has been expanded upon in terms of both technical improvements, and functionality for new applications, including event alarming and control for critical collection system management problems.

  14. Tritium monitor

    DOEpatents

    Chastagner, Philippe

    1994-01-01

    A system for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream.

  15. Tritium monitor

    DOEpatents

    Chastagner, P.

    1994-06-14

    A system is described for continuously monitoring the concentration of tritium in an aqueous stream. The system pumps a sample of the stream to magnesium-filled combustion tube which reduces the sample to extract hydrogen gas. The hydrogen gas is then sent to an isotope separation device where it is separated into two groups of isotopes: a first group of isotopes containing concentrations of deuterium and tritium, and a second group of isotopes having substantially no deuterium and tritium. The first group of isotopes containing concentrations of deuterium and tritium is then passed through a tritium detector that produces an output proportional to the concentration of tritium detected. Preferably, the detection system also includes the necessary automation and data collection equipment and instrumentation for continuously monitoring an aqueous stream. 1 fig.

  16. 24 h electrocardiographic monitoring in morbidly obese patients during short-term zero calorie diet.

    PubMed

    Zuckerman, E; Yeshurun, D; Goldhammer, E; Shiran, A

    1993-06-01

    The medical literature of the previous decades has reported sudden unexpected death among cases of very low calorie dieters. Cardiac arrhythmias, possibly produced by a prolonged QT interval, were suspected to be the main cause of death in a considerable number of these cases. The aim of this study was to investigate the occurrence of significant cardiac arrhythmias and prolongation of the QT interval, during short-term zero calorie diet, in morbidly obese patients. A group of 11 such patients (BMI > 35 kg/m2) were treated with a short-term zero calorie diet, as in-patients for ten days, followed by an out-patient regime on an 800 kcal diet. Their ages ranged from 19-58 years (mean 43.6). None had diabetes mellitus, cardiac, liver or renal disease, or thyroid or pituitary abnormalities, and none took any medication except Allupurinol 300 mg/day. We used a 24h holter monitoring system to detect cardiac arrhythmias or prolonged QT interval. Recordings were performed on the day before starting the fast, while the patients were on their regular diet, and compared with similar recordings of the same patients taken on the 10th day of the fast. No significant cardiac arrhythmias or prolongation of the QT interval were recorded during the fasting period. Short-term zero calorie dieting provided the patients with physical and psychological encouragement and is a safe method for reducing weight if it is carried out under strict medical supervision.

  17. Patient Monitoring

    NASA Technical Reports Server (NTRS)

    1978-01-01

    In photo above, the electrocardiogram of a hospitalized patient is being transmitted by telemetry. Widely employed in space operations, telemetry is a process wherein instrument data is converted to electrical signals and sent to a receiver where the signals are reconverted to usable information. In this instance, heart readings are picked up by the electrode attached to the patient's body and delivered by wire to the small box shown, which is a telemetry transmitter. The signals are relayed wirelessly to the console in the background, which converts them to EKG data. The data is displayed visually and recorded on a printout; at the same time, it is transmitted to a central control station (upper photo) where a nurse can monitor the condition of several patients simultaneously. The Patient Monitoring System was developed by SCI Systems, Inc., Huntsville, Alabama, in conjunction with Abbott Medical Electronics, Houston, Texas. In developing the system, SCI drew upon its extensive experience as a NASA contractor. The company applied telemetry technology developed for the Saturn launch vehicle and the Apollo spacecraft; instrumentation technology developed for heart, blood pressure and sleep monitoring of astronauts aboard NASA's Skylab long duration space station; and communications technology developed for the Space Shuttle.

  18. Impaired Retrieval Monitoring for Past and Future Autobiographical Events in Older Adults

    PubMed Central

    McDonough, Ian M.; Gallo, David A.

    2013-01-01

    Older adults are more likely than younger adults to confuse real and imagined events in episodic memory. This deficit may be attributed to a reduction in the specific features available for recollection (i.e. retrieval success) or to a deficit in the search and decision processes operating during recollection attempts (i.e. retrieval monitoring). The present experiments used a two-phase event-generation task to manipulate retrieval success and test for age-related deficits in retrieval monitoring. In the first phase, participants generated real autobiographical events from their past and imagined plausible future events in response to cue words. We used elaboration instructions to experimentally manipulate the amount of features associated with these generated events. In the second phase administered 24 hours later, we gave recollection tests that required participants to discriminate between these previously generated past and future events in memory. As predicted, the elaboration manipulation increased the amount of features that could be recollected in association with the generated events in both age groups (including cognitive operations in Experiment 1 and perceptual details in Experiment 2). However, older adults were more likely than younger adults to confuse past and future events in memory, and critically, elaboration did not minimize these age-related confusions. These findings imply that aging impairs the ability to accurately monitor retrieval for features that are characteristic of autobiographical events, above and beyond age-related impairments in the retrieval of the recollected information itself. PMID:23795764

  19. Relationship between ventricular ectopic beat frequency and heart rate: study in patients with severe arrhythmias.

    PubMed

    Acanfora, D; De Caprio, L; Di Palma, A; Furgi, G; Ing, F M; Migaux, M L; Rengo, F

    1993-04-01

    To evaluate and quantify the relationship between premature ventricular contractions (PVCs) and heart rate (HR), 57 patients (48 men and 8 women, mean age 59.8 +/- 7.9 years) with severe PVCs (Lown-Wolf grade > or = 3a) over 24 hours of Holter monitoring were studied. Twenty had no coronary artery disease (CAD), 25 had angiographically documented CAD, and 12 had acute myocardial infarction. All parameters of the 24-hour recordings from two ECG leads were measured by a Holter analyzer designed in our laboratory, based on fast microprocessors and controlled by a microcomputer. Scatter diagrams of the number of PVCs per minute as a function of HR and correlation coefficient were computed for various HR values corresponding to a total number of minutes greater than five. A positive correlation (r > or = 0.35) was found in most patients without CAD (85%); there was a complex relationship between the strength of the correlation and the presence of CAD or acute myocardial infarction because of a greater variability in the results of correlation coefficient analysis (coefficient of variation 62%, 208%, and 145% in patients without CAD, with CAD, and with acute myocardial infarction, respectively). The incidence of a positive correlation was similar in patients with Lown-Wolf grade III (63%), IVa (82%), or > or = IVb (67%) arrhythmias. The reproducibility of the correlation coefficient of the relationship between PVC frequency and HR was tested in 15 patients. The mean value of the correlation coefficient was 0.801 +/- 0.169 for the first test and 0.805 +/- 0.22 (p = NS) for the second test.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Machine Monitor

    NASA Technical Reports Server (NTRS)

    1994-01-01

    When a printing press jams, damage is extensive, repairs are costly, and time and production loss can be expensive. James River Corporation requested G.W. Shelton, a design engineer with Logical Control Systems to solve this problem. Shelton found the solution in a NASA Tech Brief article describing a system of pulley and belt drives. This led to the design of a system that monitors drive components for changes in relative speed that would indicate belt slippage and jam probability. When a combination of variables is not met, an emergency "stop" signal is sent to the press and an alarm is triggered.

  1. Ammonia Monitor

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Akse, James R. (Inventor); Thompson, John O. (Inventor); Atwater, James E. (Inventor)

    1999-01-01

    Ammonia monitor and method of use are disclosed. A continuous, real-time determination of the concentration of ammonia in an aqueous process stream is possible over a wide dynamic range of concentrations. No reagents are required because pH is controlled by an in-line solid-phase base. Ammonia is selectively transported across a membrane from the process stream to an analytical stream to an analytical stream under pH control. The specific electrical conductance of the analytical stream is measured and used to determine the concentration of ammonia.

  2. Monitoring microcirculation.

    PubMed

    Ocak, Işık; Kara, Atila; Ince, Can

    2016-12-01

    The clinical relevance of microcirculation and its bedside observation started gaining importance in the 1990s since the introduction of hand-held video microscopes. From then, this technology has been continuously developed, and its clinical relevance has been established in more than 400 studies. In this paper, we review the different types of video microscopes, their application techniques, the microcirculation of different organ systems, the analysis methods, and the software and scoring systems. The main focus of this review will be on the state-of-art technique, CytoCam-incident dark-field imaging, and the most recent technological and technical updates concerning microcirculation monitoring.

  3. Relation between training-induced left ventricular hypertrophy and risk for ventricular tachyarrhythmias in elite athletes.

    PubMed

    Biffi, Alessandro; Maron, Barry J; Di Giacinto, Barbara; Porcacchia, Paolo; Verdile, Luisa; Fernando, Fredrick; Spataro, Antonio; Culasso, Francesco; Casasco, Maurizio; Pelliccia, Antonio

    2008-06-15

    The aim of this study was to analyze the relation between the magnitude of training-induced left ventricular (LV) hypertrophy and the frequency and complexity of ventricular tachyarrhythmias in a large population of elite athletes without cardiovascular abnormalities. Ventricular tachyarrhythmias are a common finding in athletes, but it is unresolved as to whether the presence or magnitude of LV hypertrophy is a determinant of these arrhythmias in athletes without cardiovascular abnormalities. From 738 athletes examined at a national center for the evaluation of elite Italian athletes, 175 consecutive elite athletes with 24-hour ambulatory (Holter) electrocardiographic recordings (but without cardiovascular abnormalities and symptoms) were selected for the study group. Echocardiographic studies were performed during periods of peak training. Athletes were arbitrarily divided into 4 groups according to the frequency and complexity of ventricular arrhythmias during Holter electrocardiographic monitoring. No statistically significant relation was evident between LV mass (or mass index) and the grade or frequency of ventricular tachyarrhythmias. In addition, a trend was noted in those athletes with the most frequent and complex ventricular ectopy toward lower calculated LV mass. In conclusion, ventricular ectopy in elite athletes is not directly related to the magnitude of physiologic LV hypertrophy. These data offer a measure of clinical reassurance regarding the benign nature of ventricular tachyarrhythmias in elite athletes and the expression of athlete's heart.

  4. Prolonged P-Wave and QT Dispersion in Children with Inflammatory Bowel Disease in Remission

    PubMed Central

    Yılmaz, Nuh; Kutluk, Günsel; Dedeoğlu, Reyhan; Öztarhan, Kazım; Tulunoğlu, Aras; Şap, Fatih

    2017-01-01

    Objectives. Ulcerative colitis (UC) and Crohn's disease (CD) are chronic inflammatory bowel diseases (IBD) with unclear underlying aetiologies. Severe cardiac arrhythmias have been emphasised in a few studies on adult IBD patients. This study aimed to investigate the alteration of the P-wave and QT interval dispersion parameters to assess the risk of atrial conduction and ventricular repolarisation abnormalities in pediatric IBD patients. Patients and Methods. Thirty-six IBD patients in remission (UC: 20, CD: 16) aged 3–18 years and 36 age- and sex-matched control patients were enrolled in the study. Twelve-lead electrocardiograms were used to determine durations of P-wave, QT, and corrected QT (QTc) interval dispersion. Transthoracic echocardiograms and 24-hour rhythm Holter recordings were obtained for both groups. Results. The P-wave dispersion, QT dispersion, and QTc interval dispersion (Pdisp, QTdisp, and QTcdisp) were significantly longer in the patient group. The mean values of Pminimum, Pmaximum, and QTcminimum were significantly different between the two groups. The echocardiography and Holter monitoring results were not significantly different between the groups. Furthermore, no differences in these parameters were detected between the CD and UC groups. Conclusion. Results suggest that paediatric IBD patients may carry potential risks for serious atrial and ventricular arrhythmias over time even during remission. PMID:28316985

  5. Seismic monitoring of Central Asia territory in KNDC.

    NASA Astrophysics Data System (ADS)

    Mukambayev, Aidyn; Mikhailova, Natalia

    2015-04-01

    The Central Asia territory includes the territory of five post-Soviet countries: Kazakhstan, Kyrgyzstan, Tajikistan, Turkmenistan, and Uzbekistan. Every country has its own independent network of seismic observations and Data Processing Center aimed at every day seismic monitoring of one country territory. However, seismic hazard of Central Asia territory is stipulated by one geodynamic system that generates simultaneous large earthquakes on the territory of different countries. Thus, it is necessary to observe seismic situation for the whole region for emergency situations and for compilation of joint seismic bulletins of Central Asia region. A new contemporary network of seismic observations operated by the Institute of Geophysical Researches has been installed in Kazakhstan during last 15 years. Mainly, these are seismic arrays located throughout the country perimeter. The arrays were constructed under support of the CTBTO, and AFTAC. There are also IRIS and CAREMON stations. All data arrive to KNDC (Kazakhstan National Data Center) in real time mode. In addition, KNDC receives data in real time from stations Zalesovo (Russia), Alibek (Turkmenistan), Ala-Archa and Tokmak (Kyrgyzstan). Arrival times in the form of tables are received with 24-hours delay from almost 20 Kazakhstan stations belonging to SEME MES RK. This observation system allows monitoring the Central Asian seismicity by earthquakes with representative magnitude more than 3.5. In some regions, the events with magnitude 1.5 are recorded. As result, different products with different operativity are created for Central Asia territory: -bulletin of urgent alerts; -automatic seismic bulletin; -interactive seismic bulletin; -joint seismic operative bulletin by data arrived on-line and in table form. After that, in retrospective mode, the events nature is identified to discriminate mining explosions (up to 4000 per year) and natural earthquakes (up to 15000 per year). The results are available at KNDC web

  6. [Monitoring antibiotic consumption in the surgery and orthopaedics].

    PubMed

    Caldeira, Luís; Teixeira, Inês; Vieira, Isaura; Batel Marques, Francisco; Santiago, Luiz Miguel; Rodrigues, Victor; Fonseca, António; Varanda, Jorge; Bicó, Ana; Vasconcelos, Carlos; Polónia, José; Brochado, Jorge; Faria, Victor; Mota, António; Ramalheira, Elmano; Capão Filipe, Miguel; Marques, Margarida S A; Lopes Martins, Marta; Carmo, Eduarda; Martins, Filomena; Contente, Helena; Lobo, Marina; Gloria, Paulo; Pereira, Luis; Faria, Domitilia

    2006-01-01

    Monitoring antibiotic consumption is a valuable tool which has been increasingly used in the last years due to the current concern with the emergence of resistant microbial strains. The present study aimed at monitoring antibiotic consumption, evaluating the economic impact of hospital antibiotic prescription and assessing the relationship between the prescribed antibiotics and the indications for either prophylactic or therapeutic use. This was a longitudinal pilot-study for which data were collected in six privately managed public hospital units during the month of May 2004, with a resulting sample of 1,122 admitted patients. We observed a prescription incidence rate of 76.9%, corresponding to a total of 1,154 dispensed antimicrobials, with a mean 71.2% of these antimicrobials being dispensed for the prophylaxis of surgical site infection (SSI). The mean cost of antibiotic courses was higher in cases of "suspected infection" (9.09 euro) or "confirmed infection" (8.74 euro) and lower in cases of "prophylaxis" (5.67 euro), a finding which is explained by the shorter mean duration of the later. There was a considerable variation among the different hospital units regarding the type of antibiotic compound that was used for SSI prophylaxis, with a mean duration of antibiotic use of 2.61 days for this indication and about half of the prophylactic regimens lasting longer than 24 hours, a fact that suggests an insufficient observation of the current recommendations for antibiotic use in SSI prophylaxis. This finding indicates the need for an investigation on the actual existence of local recommendations for SSI prophylaxis in individual hospital units and also for the evaluation of the compliance of practicing surgeons with eventually existing recommendations.

  7. In-situ Real-Time Monitoring of Volatile Organic Compound Exposure and Heart Rate Variability for Patients with Multiple Chemical Sensitivity

    PubMed Central

    Mizukoshi, Atsushi; Kumagai, Kazukiyo; Yamamoto, Naomichi; Noguchi, Miyuki; Yoshiuchi, Kazuhiro; Kumano, Hiroaki; Sakabe, Kou; Yanagisawa, Yukio

    2015-01-01

    In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health 2010, 7, 4127–4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed. PMID:26445055

  8. Traffic Monitor

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Mestech's X-15 "Eye in the Sky," a traffic monitoring system, incorporates NASA imaging and robotic vision technology. A camera or "sensor box" is mounted in a housing. The sensor detects vehicles approaching an intersection and sends the information to a computer, which controls the traffic light according to the traffic rate. Jet Propulsion Laboratory technical support packages aided in the company's development of the system. The X-15's "smart highway" can also be used to count vehicles on a highway and compute the number in each lane and their speeds, important information for freeway control engineers. Additional applications are in airport and railroad operations. The system is intended to replace loop-type traffic detectors.

  9. Document Monitor

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The charters of Freedom Monitoring System will periodically assess the physical condition of the U.S. Constitution, Declaration of Independence and Bill of Rights. Although protected in helium filled glass cases, the documents are subject to damage from light vibration and humidity. The photometer is a CCD detector used as the electronic film for the camera system's scanning camera which mechanically scans the document line by line and acquires a series of images, each representing a one square inch portion of the document. Perkin-Elmer Corporation's photometer is capable of detecting changes in contrast, shape or other indicators of degradation with 5 to 10 times the sensitivity of the human eye. A Vicom image processing computer receives the data from the photometer stores it and manipulates it, allowing comparison of electronic images over time to detect changes.

  10. Blowout Monitor

    NASA Technical Reports Server (NTRS)

    1994-01-01

    C Language Integrated Production System (CLIPS), a NASA-developed software shell for developing expert systems, has been embedded in a PC-based expert system for training oil rig personnel in monitoring oil drilling. Oil drilling rigs if not properly maintained for possible blowouts pose hazards to human life, property and the environment may be destroyed. CLIPS is designed to permit the delivery of artificial intelligence on computer. A collection of rules is set up and, as facts become known, these rules are applied. In the Well Site Advisor, CLIPS provides the capability to accurately process, predict and interpret well data in a real time mode. CLIPS was provided to INTEQ by COSMIC.

  11. Rip current monitoring using GPS buoy system

    NASA Astrophysics Data System (ADS)

    Song, DongSeob; Kim, InHo; Kang, DongSoo

    2014-05-01

    The occurrence of rip current in the Haeundae beach, which is one of the most famous beaches in South Korea, has been threatening beach-goers security in summer season annually. Many coastal scientists have been investigating rip currents by using field observations and measurements, laboratory measurements and wave tank experiments, and computer and numerical modeling. Rip current velocity is intermittent and may rapidly increase within minutes due to larger incoming wave groups or nearshore circulation instabilities. It is important to understand that changes in rip current velocity occur in response to changes in incoming wave height and period as well as changes in water level. GPS buoys have been used to acquire sea level change data, atmospheric parameters and other oceanic variables in sea for the purposes of vertical datum determination, tide correction, radar altimeter calibration, ocean environment and marine pollution monitoring. Therefore, we adopted GPS buoy system for an experiment which is to investigate rip current velocity; it is sporadic and may quickly upsurge within minutes due to larger arriving wave groups or nearshore flow uncertainties. In this study, for high accurate positioning of buy equipment, a Satellite Based Argumentation System DGPS data logger was deployed to investigate within floating object, and it can be acquired three-dimensional coordinate or geodetic position of buoy with continuous NMEA-0183 protocol during 24 hours. The wave height measured by in-situ hydrometer in a cross-shore array clearly increased before and after occurrence of rip current, and wave period also was lengthened around an event. These results show that wave height and period correlate reasonably well with long-shore current interaction in the Haeundae beach. Additionally, current meter data and GPS buoy data showed that rip current velocities, about 0.2 m/s, may become dangerously strong under specific conditions. Acknowledgement This research was

  12. Lung ultrasound for monitoring cardiogenic pulmonary edema.

    PubMed

    Cortellaro, Francesca; Ceriani, Elisa; Spinelli, Monica; Campanella, Carlo; Bossi, Ilaria; Coen, Daniele; Casazza, Giovanni; Cogliati, Chiara

    2016-07-29

    Several studies address the accuracy of lung ultrasound (LUS) in the diagnosis of cardiogenic pulmonary edema (CPE) evaluating the interstitial syndrome, which is characterized by multiple and diffuse vertical artifacts (B-lines), and correlates with extravascular lung water. We studied the potential role of LUS in monitoring CPE response to therapy, by evaluating the clearance of interstitial syndrome within the first 24 h after Emergency Department (ED) admission. LUS was performed at arrival (T0), after 3 (T3) and 24 (T24) hours. Eleven regions were evaluated in the antero-lateral chest; the B-lines burden was estimated in each region (0 = no B-lines, 1 = multiple B-lines, 2 = confluent B-lines/white lung) and a mean score (B-Score, range 0-2) was calculated. Patients received conventional CPE treatment. Blood chemistry, vital signs, blood gas analysis, diuresis at T0, T3, T24 were also recorded. A complete echocardiography was obtained during hospitalization. Forty-one patients were enrolled. Respiratory and hemodynamic parameters improved in all patients between T0 and T3 and between T3 and T24. Mean B-score significantly decreased at T3 (from 1.59 ± 0.40 to 0.73 ± 0.44, P < 0.001) and between T3 and T 24 (from 0.73 ± 0.44 to 0.38 ± 0.33, P < 0.001). B-score was higher in the lower pulmonary regions at any time. At final evaluation (T24) 75 % of apical and only 38 % of basal regions were cleared. LUS allows one to assess the clearance of interstitial syndrome and its distribution in the early hours of treatment of CPE, thus representing a possible tool to guide therapy titration.

  13. A Summary of Ambient Air at John F. Kennedy Space Center with a Comparison to Data from the Florida Statewide Monitoring Network (1983-1992)

    NASA Technical Reports Server (NTRS)

    Drese, John H.

    1997-01-01

    The EPA criteria air pollutants were monitored at Kennedy Space Center (KSC) since 1983 to comply the prevention of significant deterioration requirements under the Clean Air Act amendments passed by Congress in 1977 and 1990. Monitoring results show that monthly maximum 24-hour total suspended particulates decreased from 144.6 micograms/cu m in 1988 to 73.0 micrograms/cu m in 1991 and increased to 149.3 micrograms/cu m in 1992. Inhalable particulates increased from 56.1 gg/M3 in 1983 to 131.4 micrograms/cu m in 1988, and then decreased to 38.5 micrograms/cu m in 1992. Sulfur dioxide monthly maximum 24-hour average concentrations decreased each year from 135.2 micrograms/cu m in 1983 to 33.8 micrograms/cu m in 1992. Nitrogen dioxide concentrations increased from 5.1 micrograms/cu m in 1983 to 5.9 micrograms/cu m in 1988, then decreased to 4.5 micrograms/cu m in 1992. Carbon monoxide annual average concentrations decreased from 6.2 micrograms/cu m in 1983 to 1.1 micrograms/cu m in 1988, and increased to 1.2 micrograms/cu m in 1992. Ozone maximum 1-hour concentrations increased from 98 parts per billion (ppb) in 1983 to 134 ppb in 1989, and then decreased to 80 ppb in 1992. Total annual rainfall ranged from 37.47 inches to 57.47 inches and shows a 6.6 percent increase over this same ten year period.

  14. Continuous Glucose Monitoring in Insulin-Treated Patients in Non-ICU Settings

    PubMed Central

    Gomez, Ana Maria

    2014-01-01

    Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-time CGM in the management of dysglycemia in the hospital setting. PMID:25125454

  15. Continuous glucose monitoring in insulin-treated patients in non-ICU settings.

    PubMed

    Gomez, Ana Maria; Umpierrez, Guillermo E

    2014-09-01

    Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-time CGM in the management of dysglycemia in the hospital setting.

  16. Monitoring requested for HST/COS observations of SBS 1108+574

    NASA Astrophysics Data System (ADS)

    Waagen, Elizabeth O.

    2014-04-01

    Dr. Peter Garnavich (University of Notre Dame) and Dr. Paula Szkody (University of Washington) have requested the help of AAVSO observers in monitoring the cataclysmic variable SBS 1108+574 (= CSS 120422:111127+571239) in support of upcoming Hubble Space Telescope observations. The HST COS will be carrying out far-ultraviolet spectroscopy of this target on 2014 May 12-13 UT. SBS 1108+574 is of interest because, Dr. Garnavich writes, "This CV was found in outburst by the Catalina Sky Survey and was found to have an orbital period of only 56 minutes. With this period, we expected to find a helium-rich AM CVn star, but our spectra showed both helium and hydrogen lines." The primary purpose of the AAVSO monitoring is to know whether SBS 1108+574 is in quiescence immediately prior to the observation window; if it is in outburst it will be too bright for the HST instrumentation. Based on AAVSO observations, the HST scheduling team will make the decision about 24 hours before the scheduled observing time as to whether to go forward with the HST observations. Thus, as in other campaigns similar to this one, AAVSO observations will be crucial. Finder charts with sequence may be created using the AAVSO Variable Star Plotter (http://www.aavso.org/vsp). Observations should be submitted to the AAVSO International Database. See full Alert Notice for more details and observations.

  17. Methods for monitoring and forecasting volcanic hazards and eruptions using seismology and other geophysical data

    NASA Astrophysics Data System (ADS)

    DeRoin, Nicole

    Recent eruptions of three Alaskan volcanoes have provided the opportunity to study the relationships between seismicity and volcanic hazards and other phenomena. The ability to forecast or track volcanic activity through seismicity is important because seismic monitoring can be done in real time, 24 hours a day, regardless of weather, dangerous conditions or distance. To this end, the eruptions of Veniaminof in 2005, Augustine Volcano in 2006, and Redoubt Volcano in 2009, have been studied with the focus on understanding how seismic recordings and measurements are related to physical characteristics of eruption phenomena. Positive correlations were seen in relationships between ash plume heights at Veniaminof and their accompanying seismic magnitudes, and sizes and directions of rockfalls and block-and-ash flows at Augustine with seismic amplitude ratios and magnitudes. The relationship of rockfall occurrences in background years was also correlated with seasons and weather patterns, making easier the identification of rockfall increases that may be eruption precursors. Volcanic tremor, which frequently occurs accompanying volcanic eruptions, is studied during the Redoubt eruption, through the generation of duration-amplitude plots, and the potential for a new forecasting or monitoring tool is discussed.

  18. Compartment syndrome, fasciotomy, and neuropathy after a rattlesnake envenomation: aspects of monitoring and diagnosis.

    PubMed

    Hardy, David L; Zamudio, Kelly R

    2006-01-01

    Compartment syndrome resulting from pitviper envenomation is uncommon in North America; however, when it does occur, early diagnosis, optimal antivenom therapy, and possible surgical decompression are the primary means of preventing the complication of neuropathy. Here, we report a case of a rattlesnake envenomation in the anterior compartment of the lower leg that required high doses of morphine to control pain. Although compartment syndrome was considered a possible outcome, subfascial pressures were not monitored and antivenom was discontinued at 24 hours. At 36 hours, the patient developed dorsal foot numbness and foot drop, and 15 hours later pressures within the anterior compartment were >68 mm Hg. Emergency fasciotomy was performed 59 hours postenvenomation. Peroneal neuropathy was evident after surgery and only partially recovered postoperatively. Earlier monitoring of subfascial pressures and using those pressures as a guide for decisions about time and dose of CroFab antivenom treatment may have permitted earlier surgical treatment after onset of compartment syndrome or even prevented the onset of this condition.

  19. The EFFECT trial: evaluating exacerbations, biomarkers, and safety outcomes with two dose levels of fluticasone propionate/formoterol in COPD

    PubMed Central

    Papi, Alberto; Jones, Paul W; Dalvi, Prashant S; McAulay, Kirsten; McIver, Tammy; Dissanayake, Sanjeeva

    2015-01-01

    Inhaled corticosteroid/long-acting β2-agonist combination therapy is recommended in chronic obstructive pulmonary disease (COPD) patients at high risk of exacerbations. The EFFECT (Efficacy of Fluticasone propionate/FormotErol in COPD Treatment) trial is a Phase III, 52-week, randomized, double-blind study to evaluate the efficacy and safety of two doses of fluticasone propionate/formoterol compared to formoterol monotherapy in COPD patients with FEV1 ≥50% predicted and a history of exacerbations. The primary endpoint is the annualized rate of moderate and severe exacerbations. Secondary endpoints include pre-dose FEV1, EXACT-PRO (EXAcerbations of Chronic pulmonary disease Tool – Patient-Reported Outcome)-defined exacerbations, St George’s Respiratory Questionnaire for COPD, COPD Assessment Test, and EXACT-Respiratory Symptoms total score. Lung-specific biomarkers (surfactant protein D and CC chemokine ligand-18) will be measured in a subset of patients to explore their relationship to other clinical indices in COPD and their predictive utility. Pneumonia will be diagnosed per criteria defined by the British Thoracic Society community acquired pneumonia guideline, primarily by radiological confirmation and, additionally, using clinical criteria when a chest radiograph cannot be obtained. Serial measurements of serum potassium, vital signs and electrocardiograms, 24-hour Holter monitoring, and 24-hour urinary cortisol measurement will be performed in a subset of patients in addition to conventional safety assessments. PMID:26648706

  20. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    PubMed

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  1. Exposure assessment and heart rate variability monitoring in workers handling titanium dioxide particles: a pilot study

    NASA Astrophysics Data System (ADS)

    Ichihara, Sahoko; Li, Weihua; Omura, Seiichi; Fujitani, Yuji; Liu, Ying; Wang, Qiangyi; Hiraku, Yusuke; Hisanaga, Naomi; Wakai, Kenji; Ding, Xuncheng; Kobayashi, Takahiro; Ichihara, Gaku

    2016-03-01

    Titanium dioxide (TiO2) particles are used for surface coating and in a variety of products such as inks, fibers, food, and cosmetics. The present study investigated possible respiratory and cardiovascular effects of TiO2 particles in workers exposed to this particle at high concentration in a factory in China. The diameter of particles collected on filters was measured by scanning electron microscopy. Real-time size-dependent particle number concentration was monitored in the nostrils of four workers using condensation particle counter and optical particle counter. Electrocardiogram was recorded using Holter monitors for the same four workers to record heart rate variability. Sixteen workers underwent assessment of the respiratory and cardiovascular systems. Mass-based individual exposure levels were also measured with personal cascade impactors. The primary particle diameter ranged from 46 to 562 nm. Analysis of covariance of the pooled data of the four workers showed that number of particles with a diameter <300 nm was associated positively with total number of N-N and negatively with total number of increase or decrease in successive RR intervals greater than 50 ms (RR50+/-) or percentage of RR 50+/- that were parameters of parasympathetic function. The total mass concentration was 9.58-30.8 mg/m3 during work, but significantly less before work (0.36 mg/m3). The clear abnormality in respiratory function was not observed in sixteen workers who had worked for 10 months to 13 years in the factory. The study showed that exposure to particles with a diameter <300 nm might affect HRV in workers handling TiO2 particles. The results highlight the need to investigate the possible impact of exposure to nano-scaled particles on the autonomic nervous system.

  2. Methodological Considerations in Ambulatory Skin Conductance Monitoring

    PubMed Central

    Doberenz, Sigrun; Roth, Walton T.; Maslowski, Nina I.; Wollburg, Eileen; Kim, Sunyoung

    2011-01-01

    Little is known how much skin conductance (SC) recordings from the fingers are affected by factors such as electrode site deterioration, ambient temperature (TMP), or physical activity (ACT), or by age, sex, race, or body mass index. We recorded SC, TMP, and ACT in 48 healthy control subjects for a 24-hour period, and calculated SC level (SCL), its standard deviation, the coefficient of SC variation, and frequency and amplitude of non-specific SC fluctuations. One method of assessing electrode site deterioration showed an average decline of 20 %, while a second method found no significant change. All SC measures were higher during waking than sleep. Other factors influenced different measures in different ways. Thus, 24-hour SC recording outside the laboratory is feasible, but some measures need to be corrected for the influence of confounding variables. PMID:21320551

  3. QF monitoring. [Qualifying Facilities

    SciTech Connect

    Greenwald, S. ); Hoffman, B. )

    1991-10-01

    This article examines the effects on project financing of independent power projects of the California Public Utilities Commission decision to grant authority to California utilities to monitor and enforce compliance with the Federal Energy Regulatory Commission Qualifying Facility standards. The topics of the article include monitoring proposals, monitoring guidelines, the effects of monitoring, minimizing status loss and monitoring requirements.

  4. A Distributed, Real-Time Data Monitoring System as Ground Support Equipment for Balloon-Borne Astronomy Experiments

    NASA Astrophysics Data System (ADS)

    Chen, C. M. H.; Baumgartner, W. H.; Cook, W. R.; Davis, A. J.; Harrison, F. A.

    2010-12-01

    We present a real-time data-monitoring software suite that we developed for the High Energy Focusing Telescope (HEFT). HEFT was one of the first projects to develop focusing mirrors and detectors for hard X-ray astronomy. We deployed these new technologies on the scientific ballooning platform. During a balloon flight, this so-called ‘ground support equipment’ (GSE) allows us to monitor the physical condition of the payload, and to inspect preliminary science data in real time, through displays of tables of frequently updated quantities and their averages, time-series plots, histograms, spectra, and images. Unique from previous implementations of GSE s for other experiments, our system is a server-client network that utilises TCP/IP unicast and UDP multicast to enable multiple, concurrent and independent display clients. Most of the code is in Java, and thus platform-independent. We verified that the software suite works on Linux, Mac OS/X and Windows XP, deployed it in two flight campaigns for use during on-site calibration, pre-launch practice drills, and an observation flight of 24 hours. This system, and individual ideas of its implementation, can be adapted for use in future experiments requiring sophisticated real-time monitoring and data display.

  5. Source Water Quality Monitoring

    EPA Science Inventory

    Presentation will provide background information on continuous source water monitoring using online toxicity monitors and cover various tools available. Conceptual and practical aspects of source water quality monitoring will be discussed.

  6. Daily Energy Expenditure and Its Relation to Health Care Costs in Patients Undergoing Ambulatory Electrocardiographic Monitoring.

    PubMed

    George, Jason; Abdulla, Rami Khoury; Yeow, Raymond; Aggarwal, Anshul; Boura, Judith; Wegner, James; Franklin, Barry A

    2017-02-15

    Our increasingly sedentary lifestyle is associated with a heightened risk of obesity, diabetes, heart disease, and cardiovascular mortality. Using the recently developed heart rate index formula in 843 patients (mean ± SD age 62.3 ± 15.7 years) who underwent 24-hour ambulatory electrocardiographic (ECG) monitoring, we estimated average and peak daily energy expenditure, expressed as metabolic equivalents (METs), and related these data to subsequent hospital encounters and health care costs. In this cohort, estimated daily average and peak METs were 1.7 ± 0.7 and 5.5 ± 2.1, respectively. Patients who achieved daily bouts of peak energy expenditure ≥5 METs had fewer hospital encounters (p = 0.006) and median health care costs that were nearly 50% lower (p <0.001) than their counterparts who attained <5 METs. In patients whose body mass index was ≥30 kg/m(2), there were significant differences in health care costs depending on whether they achieved <5 or ≥5 METs estimated by ambulatory ECG monitoring (p = 0.005). Interestingly, patients who achieved ≥5 METs had lower and no significant difference in their health care costs, regardless of their body mass index (p = 0.46). Patients with previous percutaneous coronary intervention who achieved ≥5 METs had lower health care costs (p = 0.044) and fewer hospital encounters (p = 0.004) than those who achieved <5 METs. In conclusion, average and peak daily energy expenditures estimated from ambulatory ECG monitoring may provide useful information regarding health care utilization in patients with and without previous percutaneous coronary intervention, irrespective of body habitus. Our findings are the first to link lower intensities of peak daily energy expenditure, estimated from ambulatory ECG monitoring, with increased health care utilization.

  7. Monitored plutonium aerosols at a soil cleanup site on Johnston Atoll

    SciTech Connect

    Shinn, J.H.; Fry, C.O.; Johnson, J.S.

    1996-01-23

    Suspended plutonium in air was monitored for four periods near the operation of a stationary sorting system used to {open_quotes}mine{close_quotes} contaminated soil on Johnston Atoll. The monitoring periods were 14 October-14 November 1992, 20 October-15 November 1993, 16 August-3 November 1994, and 17 February-27 February 1995. Pairs of high volume air samplers were located at each of four locations of the process stream: the {open_quotes}spoils pile{close_quotes} that was the feedstock, the {open_quotes}plant area{close_quotes} near the hot soil gate of the sorter, the {open_quotes}clean pile{close_quotes} conveyer area where sorted clean soil was moved, and the {open_quotes}oversize soil{close_quotes} crushing area. These locations were monitored only during the working hours, while air monitoring was also done at an upwind, {open_quotes}background{close_quotes} area 24-hours per day. The median concentrations of Pu in {open_quotes}workplace{close_quotes} air (combined spoils pile, plant area, and clean pile sites) in 1992 was 397 aCi/m{sup 3} (15 {mu}Bq/m{sup 3}), but increased to median values of 23000 aCi/m{sup 3} (852 {mu}Bq/m{sup 3}) in August-November 1994 and 29800 aCi/m{sup 3} (1100 {mu}Bq/m{sup 3}) in February 1995. The highest median value at the worksites (29800 aCi/m{sup 3}) was more than 200 times lower than the regulatory level. The highest observed value was 84200 aCi/m{sup 3} at the spoils pile site, and this was more than 70 times lower than the regulatory level. The conclusion was that, in spite of the dusty environment, and the increased level of specific activity, we did not find that the soil processing posed any significant risk to workers during the observation periods 1992-1995.

  8. The deployment of carbon monoxide wireless sensor network (CO-WSN) for ambient air monitoring.

    PubMed

    Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C; Khang, Soon-Jai

    2014-06-16

    Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011-2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1-1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring.

  9. The Deployment of Carbon Monoxide Wireless Sensor Network (CO-WSN) for Ambient Air Monitoring

    PubMed Central

    Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C.; Khang, Soon-Jai

    2014-01-01

    Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011–2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1–1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring. PMID:24937527

  10. Effect of Cabotegravir on Cardiac Repolarization in Healthy Subjects

    PubMed Central

    Lou, Yu; Buchanan, Ann M.; Chen, Shuguang; Ford, Susan L.; Gould, Elizabeth; Margolis, David; Spreen, William R.

    2016-01-01

    Abstract A randomized, partial‐blind, repeat‐dose, 3‐period crossover study (NCT02027454) assessed the effect of cabotegravir on QT interval in healthy subjects. To achieve a supratherapeutic dose, each subject received cabotegravir 150 mg (30 mg × 5 tablets) every 12 hours for a total of 3 doses over 2 days, matching placebo (every 12 hours) over 2 days, or a single open‐label 400‐mg dose of the positive control moxifloxacin, with a 21‐day washout between treatments. Blood samples for pharmacokinetic analyses were collected up to 24 hours after the third dose on day 2. QT interval data were obtained by continuous Holter monitoring for approximately 24 hours at baseline (day ‐1) and from 2 hours before to 24 hours after the third dose on day 2. Plasma cabotegravir exposure was approximately 3‐fold above clinically relevant doses. After 3 doses of 150 mg of cabotegravir administered every 12 hours, all upper limits of 2‐sided 90% confidence intervals for ΔΔQTcF (difference in time‐matched change from baseline for QTcF between cabotegravir and placebo) were <10 milliseconds. There was no relationship between cabotegravir plasma concentrations and ΔΔQTcF. No subject receiving cabotegravir had a QTcF value > 450 milliseconds. There were no serious or grade 3 or 4 adverse events or clinically significant changes in laboratory values, vital signs, or electrocardiogram results. These data demonstrate that cabotegravir at a supratherapeutic dose had no effect on cardiac repolarization. PMID:27162089

  11. [Intraoperative monitoring of cerebral blood-flow and condition of cerebral at open and endovascular interventions in carotid system].

    PubMed

    Kuntsevich, G I; Tanashian, M M; Skrylev, S I; Krotenkova, M V; Shchipakin, V L; Koshcheev, A Iu; Lagoda, O V; Gemdzhian, E G; Medvedev, R B; Kulikova, S N

    2011-01-01

    The aim of our research is to study hemodynamic and embolic situation during the carotid endarterectomy (CEA), carotid angioplastic and stenting (CAS), and to reveal the prognostic significance of the data provided by intraoperative monitoring of the brain blood flow in exposing acute ischemic lesions in brain. Intraoperative monitoring of blood flow in artery ophthalmic vas carried out with 60% of patients, in the middle cerebral artery-with 40% during the main stages of CEA, and with 64 patients in the middle cerebral artery during CAS. The comparison of the data of intraoperative monitoring of blood flow in middle cerebral artery with the result of brain diffusion-weighted magnetic resonance imaging (DW-MRI) 24 hours after the operation shows, that solid microembolic signals and vasospasm are prognostic signals (sensibility and specifics make up 95%) in the development of acute ischemic cerebral lesions. The monitoring of blood flow in artery ophthalmic is of the greatest diagnostic value in estimation of the hemodynamic situation, but it is of the lowest practical value in detecting microembolic signals. According to the data of the intraoperative blood flow monitoring in middle cerebral artery in group CEA the development of acute ischemic cerebral lesions were predicted with 11,1% of patients and the cause of postoperative stroke, developed by 2,9% of the patients, was specified. According to the result of DW-MRI, acute ischemic cerebral lesions were diagnosed with 21% of patients, that is, 18% of ischemic cerebral lesions were asymptomatic. In group CAS ischemic cerebral lesions were prognosed with 30% of patients, actually they were later detected with 40,6% of cases by means of DW-MRI. According to the data of intraoperative of blood flow monitoring the cause of the development of postoperative stroke was specified in 6,2% of cause; in 34,4% of cause the acute ischemic cerebral lesions were asymptomatic.

  12. The immediate and 24-hour follow-up effect of unilateral lumbar Z-joint mobilisation on posterior chain neurodynamics.

    PubMed

    Shankar Ganesh, G; Mohanty, Patitapaban; Smita Pattnaik, Swati

    2015-04-01

    Few studies have reported the effects of lumbar spine mobilization on neurodynamics. In a recent study, Szlezak et al. (2011) reported immediate improvement of posterior chain neurodynamics [range of passive straight leg raise (SLR)] following ipsilateral lumbar spine zygopophyseal (Z) joint mobilization. We re-duplicated the study with a 24 h follow-up measurement. Sixty healthy college students were assigned to two groups, mobilization and control. The mobilization group received ipsilateral grade 3 Maitland mobilizations to Z joint at a frequency of 2 MHz for 3 min and the control group received no treatment. The SLR was measured before and after the intervention for both the groups on the day of testing and 24-h later. Repeated measures ANOVA showed statistically significant pre to post improvement in SLR range after mobilization. The improvement was retained at 24-h. The results of the study are consistent with Szlezak et al. (2011).

  13. Ram seminal plasma improves pregnancy rates in ewes cervically inseminated with ram semen stored at 5 °C for 24 hours.

    PubMed

    López-Pérez, A; Pérez-Clariget, R

    2012-01-15

    In this study, we compared pregnancy rates obtained using ram semen stored at 5 °C for 24 h, with ram or bull seminal plasma (SP) added to TRIS-egg yolk extender. During the breeding period, 670 adult Corriedale ewes were cervically inseminated with semen (2 × 10(8) sperm in a volume of 0.2 mL) from eight adult Corriedale rams. Ejaculates, obtained using an artificial vagina, were split into three aliquots and diluted with the following: TRIS-egg yolk based extender (T), T + 30% ram SP (R), or T + 30% bull SP (B). Samples were refrigerated and stored at 5 °C for 24 h until used for AI. Pregnancy was assessed by ultrasonography 35 to 40 d after AI. Pregnancy rate was not affected by ram (P = 0.77) or breeding period (P = 0.43), and there were no interactions between extender and ram (P = 0.94), or extender and breeding period (P = 0.24). However, there was an effect of extender (P = 0.0009) on pregnancy rates; ram SP, but not bull SP, increased pregnancy rates compared with extender without SP (49.7, 38.1, and 31.1%, for R, B, and T respectively). In conclusion, ram SP added to TRIS-egg yolk extender had a beneficial effect on the pregnancy rate of ram sperm stored at 5 °C for 24 h and used for cervical insemination of ewes.

  14. Validity of a self-administered diet history questionnaire for assessment of sodium and potassium: comparison with single 24-hour urinary excretion.

    PubMed

    Sasaki, S; Yanagibori, R; Amano, K

    1998-06-01

    We developed a self-administered diet history questionnaire (DHQ) for use in prevention and control of cardiovascular diseases and cancer, and validated it by comparison with single 24-h urinary excretion of sodium (Na) and potassium (K). The subjects were 154 male and 69 female freshmen university students. Mean intakes (mmol/day) assessed by DHQ and the urinary excretion of Na were 196 and 165 respectively for men and 179 and 136 respectively for women. Those of K were 61.5 and 43.9 respectively for men and 56.8 and 41.6 respectively for women. The ratios of urinary excretion to dietary intake of Na were 0.97 in men and 0.84 in women. Those of K were 0.78 in men and 0.80 in women. The results for both Na and K were reasonable, except for Na in men. When Pearson correlation was examined between dietary and urinary Na and K, no significant correlations for Na in men (r=0.14) or women (r=0.23, p=0.06), or significant correlations for K in men (r=0.34, p<0.001) or women (r=0.40, p<0.001) were observed. The results suggest a reasonable ability to estimate a subject mean for Na in women, K in both sexes, and individual level for K for both sexes. The validity for individual level for Na intake is not conclusive because the duration of urine collection was too short.

  15. Effect of 24 Hours of Sleep Deprivation on Auditory and Linguistic Perception: A Comparison among Young Controls, Sleep-Deprived Participants, Dyslexic Readers, and Aging Adults

    ERIC Educational Resources Information Center

    Fostick, Leah; Babkoff, Harvey; Zukerman, Gil

    2014-01-01

    Purpose: To test the effects of 24 hr of sleep deprivation on auditory and linguistic perception and to assess the magnitude of this effect by comparing such performance with that of aging adults on speech perception and with that of dyslexic readers on phonological awareness. Method: Fifty-five sleep-deprived young adults were compared with 29…

  16. [Preparation of a levodopa/carbidopa solution in ascorbic acid (citridopa) and chromatographic and electrochemical assessment of its stability over 24 hours].

    PubMed

    López Lozano, J J; Moreno Cano, R

    1995-04-01

    Levodopa/inhibitor improves motor function in parkinsonian patients. In its usual tablet form, however, its efficacy is reduced after several years, partially due to absorption deficiencies and changes in plasma kinetics; thus, other therapeutic strategies to provide a stable, easy to prepare formula are being sought. One such approach could be to dissolve L-dopa/carbidopa in ascorbic acid. This report describes the preparation method and demonstrates the stability of the sample using High pressure liquid cromatography (HPLC) with electrochemical detection. Regardless of the number of tablets the patient takes, the concentration of L-dopa/carbidopa/ascorbic acid remains constant (1/0.25/2 mg/ml). Thus, a patient taking 5 tablets of Sinemet Plus a day, would pulverize them in a glass, ceramic or marble mortar and add them to a measuring cup containing a 1 gram tablet of vitamin C (Redoxon) dissolved in 500 cc of cold water. This would be shaken or stirred until the Sinemet powder had dissolved. A few particles remaining in suspension after this process would be of no concern. The liquid would be stored in the refrigerator in an opaque or aluminum foil-covered glass bottle or, if possible, in several small dose-size vials. Using a measuring cup, a test tube and a syringe, the correct volume can be drawn out of the bottle and shaken well before drinking. The solution would be taken at regular intervals throughout the day (which vary from one patient to another) to maintain stable plasma L-dopa levels.

  17. Antiproteinuric effect of cilnidipine in hypertensive Japanese treated with renin-angiotensin-system inhibitors - a multicenter, open, randomized trial using 24-hour urine collection.

    PubMed

    Miwa, Yoshikazu; Tsuchihashi, Takuya; Ohta, Yuko; Tominaga, Mitsuhiro; Kawano, Yuhei; Sasaguri, Toshiyuki; Ueno, Michio; Matsuoka, Hiroaki

    2010-01-01

    Sustained proteinuria is an important risk factor for not only renal but also cardiovascular morbidity and mortality. Although inhibitors of the renin-angiotensin system (RAS) have been shown to reduce proteinuria. Monotherapy with those drugs is often insufficient for optimal blood pressure (BP)-lowering and therefore, combined therapy is needed. Recent reports suggested that cilnidipine, a dual L-/N-type calcium channel blocker, has renoprotective effect by dilating both efferent and afferent arterioles. In this study, a multicenter, open, randomized trial was designed to compare the antiproteinuric effect between cilnidipine and amlodipine when coupled with RAS inhibitors in hypertensive patients with significant proteinuria. Proteinuria was evaluated by 24-h home urine collection for all patients. A total of 35 proteinuric (>0.1 g/day) patients with uncontrolled BP (>135/85 mmHg) were randomized to receive either cilnidipine (n = 18) or amlodipine (n = 17) after a 6-month treatment with RAS inhibitors and were followed for 48 weeks. At baseline, the cilnidipine group was older and had lower body mass index (BMI) compared to the amlodipine group. After 32 weeks of treatment, diastolic blood pressure (DBP) was slightly, but significantly reduced, in the cilnidipine group, although systolic blood pressure (SBP) and mean BP did not differ. The urinary protein did not differ at baseline (cilnidipine group 0.48 g/day, amlodipine group 0.52 g/day); however, it significantly decreased in the cilnidipine group (0.22 g/day) compared to the amlodipine group (0.50 g/day) after 48 weeks of treatment. Our findings suggest that cilnidipine is superior to amlodipine in preventing the progression of proteinuria in hypertensive patients even undergoing treatment with RAS inhibitors.

  18. Urinary catecholamines in essential hypertension: results of 24-hour urine catecholamine analyses from patients in the Medical Research Council trial for mild hypertension and from matched controls.

    PubMed

    Brown, M J; Causon, R C; Barnes, V F; Brennan, P; Barnes, G; Greenberg, G

    1985-10-01

    Four consecutive 24-h urine samples were collected from 134 male and 134 female placebo-treated patients in the Medical Research Council Trial for Mild Hypertension. Similar samples were collected from age and sex-matched normotensive controls. On the fourth day noradrenaline excretion was 22.05 +/- 1.01 nmol/mmol creatinine in the hypertensives compared with 22.22 +/- 1.16 nmol/mmol creatinine in the controls. Adrenaline excretion on the same day was 6.13 +/- 0.33 nmol/mmol creatinine in the hypertensive subjects compared with 6.32 +/- 0.38 nmol/mmol creatinine in the controls. There was no significant difference for either catecholamine between the two groups. However, in the control group there was a highly significant correlation between excretion of adrenaline and systolic blood pressure (r = 0.218, p = 0.0004) and between noradrenaline excretion and systolic blood pressure (r = 0.200, p = 0.001). Catecholamine excretion and blood pressure were not significantly correlated in the hypertensive patients. There were no significant correlations in either group between catecholamine excretion and heart rate, caffeine intake, nicotine consumption or the Bortner self-assessment score of personality type. This study has found no evidence of elevated sympathoadrenal activity in mild hypertensives. The correlations in the control group may reflect the role of sympathoadrenal activity in acute fluctuations in blood pressure or may suggest that the level of blood pressure within the 'normal' range depends in part on the level of sympathoadrenal activity.

  19. Diagnostic accuracy of plasma free metanephrines in a seated position compared with 24-hour urinary metanephrines in the investigation of pheochromocytoma.

    PubMed

    Kim, Hye Jeong; Lee, Ji In; Cho, Yoon Young; Lee, Soo Youn; Kim, Jung Han; Jung, Byong Chang; Kim, Sun Wook; Chung, Jae Hoon; Min, Yong-Ki; Lee, Myung-Shik; Lee, Moon-Kyu; Kim, Jae Hyeon

    2015-01-01

    The aim of this study was to determine the diagnostic efficacy of free metanephrines in plasma samples drawn in the seated position compared with 24-h urinary metanephrines in detecting pheochromocytomas in Asian patients. This prospective study was conducted at Samsung Medical Center between May 2010 and July 2011. The study contained 245 subjects, including 28 patients with histologically-proven pheochromocytoma, 44 with histologically-proven non-pheochromocytoma, 112 controls suspected of having tumors but with negative investigations during two or more years of follow-up, and 45 healthy normotensive volunteers. Plasma-free metanephrines were measured by LC-MS/MS. The cut-off values with optimal sensitivity and specificity for plasma metanephrine and plasma normetanephrine were 0.33 nmol/L and 0.61 nmol/L, respectively. Both the plasma metanephrines measurement and urinary metanephrines measurement had a sensitivity of 96.4% (p = 1.00). However, the urinary metanephrines measurement was significantly more specific than the plasma metanephrines measurement (94.2% vs. 75.6%; p < 0.001). When we applied cut-off values based on BMI, specificity improved from 75.6% to 87.2%, with a comparable gain in sensitivity. From a diagnostic perspective, measurement of free metanephrines in plasma drawn in the seated position is highly sensitive but insufficiently specific when compared with measurement of 24-h urinary fractionated metanephrines. The specificity may be improved by applying cut-off values based on BMI. We suggest that free metanephrines in plasma drawn from seated position can also be used as an initial screening test to ensure that pheochromocytomas are not missed in Asian patients.

  20. [Clinical study of 38 cases of pheochromocytoma --correlation between the instability of intraoperative blood pressure and 24-hour urinary vanillylmandelic acid].

    PubMed

    Onuki, Tatsuaki; Yamagishi, Takuya; Teranishi, Jun-ichi; Suzuki, Koutaro; Kondo, Keiichi; Nakaigawa, Noboru; Saito, Kazuo; Noguchi, Kazumi; Kubota, Yoshinobu

    2007-07-01

    Pheochromocytoma is a rare tumor of chromaffin tissues most commonly arising from the adrenal medulla. We retrospectively reviewed the records of 38 patients with pheochromocytoma who underwent surgical treatment between 1977 and 2004 at our Yokohama City University Medical Center and Yokohama City University Hospital. Twenty two patients (57.9%) were females and 16 (42.1%) were males. The most frequent symptoms were headache (58%). One patient had bilateral adrenal tumors and pathological examination revealed malignant pheochromocytoma. Six patients had an extra-adrenal tumor and in 2 patients the tumor occurred in the urinary bladder. Twelve patients (31.6%) had sustained hypertension, 21 patients (55.3%) had paroxysmal hypertension and 5 patients (13.1%) remained normotensive. The 24-h urinary total metanephrines and vanillylmandelic acid (VMA) were the most sensitive biochemical tests for the diagnosis of pheochromocytoma. The sensitivity of urinary total metanephrines was 92.0% for all the patients and was 92.3% for the patients without paroxysmal hypertension. Fifteen patients had intraoperative hypertensive reactions in the surgical manipulation or hypotension after tumor resection. This group had more urinary excretion of VMA before surgery, compared with that with stable intraoperative blood pressure (p < 0.005).

  1. A comparison of biochemical tests for pheochromocytoma: measurement of fractionated plasma metanephrines compared with the combination of 24-hour urinary metanephrines and catecholamines.

    PubMed

    Sawka, Anna M; Jaeschke, Roman; Singh, Ravinder J; Young, William F

    2003-02-01

    We compared the diagnostic efficacy of fractionated plasma metanephrine measurements to measurements of 24-h urinary total metanephrines and catecholamines in outpatients tested for pheochromocytoma at Mayo Clinic Rochester from January 1, 1999, until November 27, 2000. Catecholaminesecreting tumors were histologically proven. The sensitivity of fractionated plasma metanephrines was 97% (30 of 31 patients), compared with a sensitivity of 90% (28 of 31) for urinary total metanephrines and catecholamines (P = 0.63). The specificity of fractionated plasma metanephrines was 85% (221 of 261), compared with 98% (257 of 261; P < 0.001) for urinary measurements. The likelihood ratios for positive tests were 6.3 (95% confidence interval, 4.7 to 8.5) for fractionated plasma metanephrines and 58.9 (95% confidence interval, 22.1 to 156.9) for urinary total metanephrines and catecholamines. An adrenal pheochromocytoma was missed by urinary testing in two patients with familial syndromes and one asymptomatic patient with an incidentally discovered adrenal mass. An extra-adrenal paraganglioma was missed by plasma testing in one patient. In conclusion, measurements of 24-h urinary total metanephrines and catecholamines yield fewer false-positive results, an attribute preferred for testing low-risk patients, but fractionated plasma metanephrine measurements may be preferred in high-risk patients with familial endocrine syndromes.

  2. Vancomycin 24-Hour Area under the Curve/Minimum Bactericidal Concentration Ratio as a Novel Predictor of Mortality in Methicillin-Resistant Staphylococcus aureus Bacteremia.

    PubMed

    Britt, Nicholas S; Patel, Nimish; Horvat, Rebecca T; Steed, Molly E

    2016-05-01

    While previous studies have examined the association between vancomycin (VAN) exposure and MIC with regard to outcomes in methicillin-resistant Staphylococcus aureus bacteremia (MRSA-B), none have explored if a relationship exists with the VAN minimum bactericidal concentration (MBC). The objective of this study was to evaluate the VAN 24-h area under the curve (AUC24)/MBC ratio as a pharmacodynamic predictor of mortality. This retrospective cohort study included patients treated with VAN for MRSA-B with the primary outcome of 30-day all-cause mortality. Data collected included patient demographics, comorbidities, antimicrobial treatment data, therapeutic drug levels, and laboratory and microbiological data. Vancomycin MICs and MBCs were determined by Etest (MIC only) and broth microdilution (BMD). The vancomycin AUC24 was determined by pharmacokinetic maximum a posteriori probability Bayesian (MAP-Bayesian) analysis. The most significant breakpoint for 30-day mortality was determined by classification and regression tree (CART) analysis. The association between pharmacodynamic parameters (VAN AUC24/MICBMD, VAN AUC24/MICEtest, and AUC24/MBCBMD) and mortality were determined by χ(2) and multivariable Poisson regression. Overall mortality in this cohort (n = 53) was 20.8% (n = 11/53), and all corresponding MRSA blood isolates were VAN susceptible (MIC range, 0.5 to 2 μg/ml; MIC50, 1 μg/ml; MIC90, 1 μg/ml). The CART-derived breakpoints for mortality were 176 (VAN AUC24/MBC) and 334 (VAN AUC24/MICBMD). In multivariable analysis, the association between a VAN AUC24/MBC of ≥176 and survival persisted, but VAN AUC24/MICBMD values (≥334 or ≥400) were not associated with improved mortality. In conclusion, VAN AUC24/MBC was a more important predictor of 30-day mortality than VAN AUC24/MIC for MRSA-B.

  3. Using an Adenosine Triphosphate Bioluminescent Assay to Determine Effective Antibiotic Combinations against Carbapenem-Resistant Gram Negative Bacteria within 24 Hours

    PubMed Central

    Cai, Yiying; Leck, Hui; Lim, Tze Peng; Teo, Jocelyn; Lee, Winnie; Hsu, Li Yang; Koh, Tse Hsien; Tan, Thuan Tong; Tan, Thean-Yen; Kwa, Andrea Lay-Hoon

    2015-01-01

    Background Current in vitro combination testing methods involve enumeration by bacterial plating, which is labor-intensive and time-consuming. Measurement of bioluminescence, released when bacterial adenosine triphosphate binds to firefly luciferin-luciferase, has been proposed as a surrogate for bacterial counts. We developed an ATP bioluminescent combination testing assay with a rapid turnaround time of 24h to determine effective antibiotic combinations. Methods 100 strains of carbapenem-resistant (CR) GNB [30 Acinetobacter baumannii (AB), 30 Pseudomonas aeruginosa (PA) and 40 Klebsiella pneumoniae (KP)] were used. Bacterial suspensions (105 CFU/ml) were added to 96-well plates containing clinically achievable concentrations of multiple single and two-antibiotic combinations. At 24h, the luminescence intensity of each well was measured. Receiver operator characteristic curves were plotted to determine optimal luminescence threshold (TRLU) to discriminate between inhibitory/non-inhibitory combinations when compared to viable plating. The unweighted accuracy (UA) [(sensitivity + specificity)/2] of TRLU values was determined. External validation was further done using 50 additional CR-GNB. Results Predictive accuracies of TRLU were high for when all antibiotic combinations and species were collectively analyzed (TRLU = 0.81, UA = 89%). When individual thresholds for each species were determined, UA remained high. Predictive accuracy was highest for KP (TRLU = 0.81, UA = 91%), and lowest for AB (TRLU = 0.83, UA = 87%). Upon external validation, high overall accuracy (91%) was observed. The assay distinguished inhibitory/non-inhibitory combinations with UA of 80%, 94% and 93% for AB, PA and KP respectively. Conclusion We developed an assay that is robust at identifying useful combinations with a rapid turn-around time of 24h, and may be employed to guide the timely selection of effective antibiotic combinations. PMID:26460891

  4. 24-HOUR DIFFUSIVE SAMPLING OF TOXIC VOCS IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - LABORATORY STUDIES

    EPA Science Inventory

    Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity, and ozon...

  5. Phase I Trial of ISIS 5132, an antisense oligonucleotide inhibitor of c-raf-1, administered by 24-hour weekly infusion to patients with advanced cancer.

    PubMed

    Rudin, C M; Holmlund, J; Fleming, G F; Mani, S; Stadler, W M; Schumm, P; Monia, B P; Johnston, J F; Geary, R; Yu, R Z; Kwoh, T J; Dorr, F A; Ratain, M J

    2001-05-01

    Raf-1 is a serine/threonine kinase that functions as a critical effector of Ras-mediated signal transduction via the mitogen-activated protein kinase pathway. Constitutive activation of this pathway directly contributes to malignant transformation in many human tumors. A 20-base phosphorothioate oligonucleotide complementary to c-raf-1 mRNA (ISIS 5132; CGP 69846A) has been shown to specifically suppress Raf-1 expression both in vitro and in vivo. This Phase I trial, involving 22 patients with advanced cancer, was designed to evaluate the safety, feasibility, and maximum tolerated dose of ISIS 5132 administration as a weekly 24-h i.v. infusion. Pharmacokinetic analysis was performed, and c-raf-1 mRNA levels in peripheral blood mononuclear cells were assessed using quantitative reverse transcription-PCR. This trial defined a maximum tolerated dose of 24 mg/kg/week on this schedule. Two of four patients treated at 30 mg/kg/week had serious adverse events after the first dose of ISIS 5132, including acute hemolytic anemia and acute renal failure and anasarca. There were no major responses documented. Dose-dependent complement activation was demonstrated on this schedule, but not on previously evaluated schedules, of ISIS 5132 administration. In contrast to other trials of ISIS 5132, there appeared to be no consistent suppression of peripheral blood mononuclear cell c-raf-1 mRNA level on this schedule at any of the dose levels analyzed. These data suggest that the efficacy and toxicity profiles of antisense oligonucleotides may be highly dependent on the schedule of administration and support the analysis of the putative molecular target in the evaluation of novel therapeutics.