Science.gov

Sample records for 24-hour urine collections

  1. Urine 24-hour volume

    MedlinePlus

    ... in a day, such as: Creatinine Sodium Potassium Nitrogen Protein This test may also be done if ... disease Potassium urine test Sodium urine test Urea nitrogen urine test Urination - excessive amount Urine output - decreased ...

  2. 24-hour urine protein

    MedlinePlus

    ... a blockage of blood vessels, or other causes Multiple myeloma Healthy people may have higher than normal urine ... Distal Hemolytic anemia Macroglobulinemia of Waldenstrom Microalbuminuria test Multiple myeloma Nephrotic syndrome Proximal Wilson disease Update Date 11/ ...

  3. The Impact of Using Different Methods to Assess Completeness of 24-Hour Urine Collection on Estimating Dietary Sodium.

    PubMed

    Wielgosz, Andreas; Robinson, Christopher; Mao, Yang; Jiang, Ying; Campbell, Norm R C; Muthuri, Stella; Morrison, Howard

    2016-06-01

    The standard for population-based surveillance of dietary sodium intake is 24-hour urine testing; however, this may be affected by incomplete urine collection. The impact of different indirect methods of assessing completeness of collection on estimated sodium ingestion has not been established. The authors enlisted 507 participants from an existing community study in 2009 to collect 24-hour urine samples. Several methods of assessing completeness of urine collection were tested. Mean sodium intake varied between 3648 mg/24 h and 7210 mg/24 h depending on the method used. Excluding urine samples collected for longer or shorter than 24 hours increased the estimated urine sodium excretion, even when corrections for the variation in timed collections were applied. Until an accurate method of indirectly assessing completeness of urine collection is identified, the gold standard of administering para-aminobenzoic acid is recommended. Efforts to ensure participants collect complete urine samples are also warranted.

  4. Measuring residual renal function in dialysis patients: can we dispense with 24-hour urine collections?

    PubMed

    Davenport, Andrew

    2016-05-01

    Residual renal function is associated with improved survival and quality of life for dialysis patients. Whereas residual renal function is monitored in peritoneal dialysis patients, many hemodialysis centers simply concentrate on achieving dialyzer urea clearance targets. Accurately quantifying residual renal function from urine collections is arduous. Thus, there is a clinical need to develop alternative methods of assessing residual renal function based on serum testing, especially for patients receiving less than thrice weekly dialysis.

  5. Comparison of Population Iodine Estimates from 24-Hour Urine and Timed-Spot Urine Samples

    PubMed Central

    Cogswell, Mary E.; Swanson, Christine A.; Sullivan, Kevin M.; Chen, Te-Ching; Carriquiry, Alicia L.; Dodd, Kevin W.; Caldwell, Kathleen L.; Wang, Chia-Yih

    2014-01-01

    Background: Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr×predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Methods: Volunteers aged 18–39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland–Altman plots. Results: Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3–156.2 μg/L; I/Cr 103.6–114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7–163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5–187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Conclusions: Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr×predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and

  6. Estimation of Daily Sodium and Potassium Excretion Using Spot Urine and 24-Hour Urine Samples in a Black Population (Benin).

    PubMed

    Mizéhoun-Adissoda, Carmelle; Houehanou, Corine; Chianéa, Thierry; Dalmay, François; Bigot, André; Preux, Pierre-Marie; Bovet, Pascal; Houinato, Dismand; Desport, Jean-Claude

    2016-07-01

    The 24-hour urine collection method is considered the gold standard for the estimation of ingested potassium and sodium. Because of the impracticalities of collecting all urine over a 24-hour period, spot urine is often used for epidemiological investigations. This study aims to assess the agreement between spot urine and 24-hour urine measurements to determine sodium and potassium intake. A total of 402 participants aged 25 to 64 years were randomly selected in South Benin. Spot urine was taken during the second urination of the day. Twenty-four-hour urine was also collected. Samples (2-mL) were taken and then stored at -20°C. The analysis was carried out using potentiometric dosage. The agreement between spot urine and 24-hour urine measurements was established using Bland-Altman plots. A total of 354 results were analyzed. Daily sodium chloride and potassium chloride urinary excretion means were 10.2±4.9 g/24 h and 2.9±1.4 g/24 h, respectively. Estimated daily sodium chloride and potassium chloride means from the spot urine were 10.7±7.0 g/24 h and 3.9±2.1 g/24 h, respectively. Concordance coefficients were 0.61 at d=-0.5 g, (d±2SD=-11 g and 10.1 g) for sodium chloride and 0.61 at d=-1 g, (d±2SD=-3.8 g and 1.8 g) for potassium chloride. Spot urine method is acceptable for estimating 24-hour urinary sodium and potassium excretion to assess sodium and potassium intake in a black population. However, the confidence interval for the mean difference, which is too large, makes the sodium chloride results inadmissible at a clinical level.

  7. Self-Renewal and Differentiation Capacity of Urine-Derived Stem Cells after Urine Preservation for 24 Hours

    PubMed Central

    Shi, Yingai; Bharadwaj, Shantaram; Leng, Xiaoyan; Zhou, Xiaobo; Liu, Hong; Atala, Anthony; Zhang, Yuanyuan

    2013-01-01

    Despite successful approaches to preserve organs, tissues, and isolated cells, the maintenance of stem cell viability and function in body fluids during storage for cell distribution and transportation remains unexplored. The aim of this study was to characterize urine-derived stem cells (USCs) after optimal preservation of urine specimens for up to 24 hours. A total of 415 urine specimens were collected from 12 healthy men (age range 20–54 years old). About 6×104 cells shed off from the urinary tract system in 24 hours. At least 100 USC clones were obtained from the stored urine specimens after 24 hours and maintained similar biological features to fresh USCs. The stored USCs had a “rice grain” shape in primary culture, and expressed mesenchymal stem cell surface markers, high telomerase activity, and normal karyotypes. Importantly, the preserved cells retained bipotent differentiation capacity. Differentiated USCs expressed myogenic specific proteins and contractile function when exposed to myogenic differentiation medium, and they expressed urothelial cell-specific markers and barrier function when exposed to urothelial differentiation medium. These data demonstrated that up to 75% of fresh USCs can be safely persevered in urine for 24 hours and that these cells stored in urine retain their original stem cell properties, indicating that preserved USCs could be available for potential use in cell-based therapy or clinical diagnosis. PMID:23349776

  8. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

    PubMed Central

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. Results A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Conclusions Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. PMID:27286119

  9. Association between Sleep Duration and 24-Hour Urine Free Cortisol in the MrOS Sleep Study

    PubMed Central

    Rao, Madhu N.; Blackwell, Terri; Redline, Susan; Punjabi, Naresh M.; Barrett-Connor, Elizabeth; Neylan, Thomas C.; Stone, Katie L.

    2013-01-01

    Context Short sleep duration is associated with adverse health outcomes, but the mechanisms involved are unknown. It has been postulated that short sleep duration may elevate cortisol levels, but studies have had conflicting results. It is unclear whether these differing findings may be due to methodological issues, such as assessment of sleep duration. Specifically, objective versus subjective methods of measuring habitual sleep duration may account for the conflicting results found in epidemiological studies. Objective Our goal was to determine whether habitual sleep duration, measured objectively (by actigraphy) and subjectively (by self-report), was associated with 24-hour urine free cortisol (UFC), a measure of integrated cortisol secretion. Our secondary goal was to determine whether slow wave sleep (SWS, determined by polysomnography) was associated with 24-hour UFC. Design/Setting Cross sectional study of community dwelling older men. Patients/Participants 325 men (mean age = 76.6 years, SD = 5.5) from the Portland site of the MrOS Sleep Study, who underwent 24-hour urine collection, polysomnography, actigraphy and sleep questionnaire. Primary Outcome 24-hour UFC. Results In this study of community dwelling older men, self-reported sleep duration was inversely related to 24-hour UFC levels. Participants reporting <5 hours of habitual sleep had an adjusted mean 24-hour UFC of 29.8 ug, compared to 28.0 ug in participants reporting >5 to <8 hours of sleep 25.5 ug in those reporting >8 hours of habitual sleep. However, sleep duration determined by actigraphy was not associated with 24-hour UFC in either univariable or multivariable regression models. SWS was not associated with 24-hour UFC. Conclusion Objectively measured (i.e., actigraphic) sleep duration is not associated with 24-hour UFC in these community dwelling older men. This finding, together with prior studies, suggests that elevated levels of integrated cortisol secretion is not the

  10. Influence of Overweight on 24-Hour Urine Chemistry Studies and Recurrent Urolithiasis in Children

    PubMed Central

    Chung, Jae Dong; Kim, Tae-Hyoung; Myung, Soon Chul; Moon, Young Tae; Kim, Kyung Do

    2012-01-01

    Purpose We investigated the influence of overweight on 24-hour urine chemistry studies and recurrent urolithiasis (UL) in children. Materials and Methods A retrospective cohort study was designed to assess children who presented with UL at a pediatric institution between 1985 and 2010. We calculated body mass index percentile (BMIp) adjusted for gender and age according to the 2007 Korean Children and Adolescents Growth Chart and stratified the children into 3 BMI categories: lower body weight (LBW, BMIp≤10), normal BW (NBW, 10urine chemistry studies (urine volume, creatinine, calcium, oxalate, citrate, and pH) were compared between the 3 BMIp groups. Univariate and multivariate analyses were performed to assess independent risk factors for stone recurrence. Results A total of 125 patients were included. The age of the patients in the NBW group was older than that of patients in the LBW group, but 24-hour urine chemistry studies did not differ significantly between the three groups. Mean urine citrate levels were lower (0.273±0.218 mg/mg/d vs. 0.429±0.299 mg/mg/d, p<0.05) and the incidence of hypocitraturia was higher (81.5% vs. 45.7%, p<0.05)) in the recurrent stone former group. In the univariate analysis, hypocitraturia and acidic urinary pH were risk factors, but in the multivariate analysis, only hypocitraturia was a risk factor for stone recurrence (hazard ratio, 3.647; 95% confidence interval, 1.047 to 12.703). In the Kaplan-Meier curve, the hypocitraturia group showed higher recurrence than did the normocitraturia group (p<0.05). Conclusions Unlike in adults, in children, overweight adjusted for gender and age was not associated with 24-hour urine chemistry studies and was not a risk factor for recurrent UL. Hypocitraturia was the only risk factor for UL in children. PMID:22536471

  11. Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

    SciTech Connect

    Carbaugh, Eugene H.

    2008-10-01

    The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

  12. Effects of dietary interventions on 24-hour urine parameters in patients with idiopathic recurrent calcium oxalate stones.

    PubMed

    Kıraç, Mustafa; Küpeli, Bora; Irkilata, Lokman; Gülbahar, Ozlem; Aksakal, Nur; Karaoğlan, Ustünol; Bozkırlı, Ibrahim

    2013-02-01

    The aim of this study is to investigate the effects of dietary factors on 24-hour urine parameters in patients with idiopathic recurrent calcium oxalate stones. A total of 108 of idiopathic recurrent calcium oxalate stones were included in the study. A 24-hour urinalysis was performed and metabolic abnormalities were measured for all of the patients. All of the patients were given specialized diets for their 24-hour urine abnormalities. At the end of first month, the same parameters were examined in another 24-hour urinalysis. Hyperoxaluria, hypernatruria, and hypercalciuria were found in 84 (77%), 43 (39.8%), and 38 (35.5%) of the patients, respectively. The differences between the oxalate, sodium, volume, uric acid, and citrate parameters before and after the dietary intervention were significant (p < 0.05). The calcium parameters were not significantly different before and after the intervention. We found that oxalate, sodium, volume, uric acid, and citrate-but not calcium-abnormalities in patients with recurrent calcium oxalate stones can be corrected by diet. The metabolic profiles of idiopathic calcium oxalate stone patients should be evaluated and the appropriate dietary interventions should be implemented to decrease stone recurrence.

  13. Collection of a 24-Hour Urine Specimen (Beyond the Basics)

    MedlinePlus

    ... the Licensed Materials from any location via the Internet. b. STANDALONE WORKSTATION: A standalone subscription permits multiple ... computer. A Standalone Workstation license does not include Internet access to the Licensed Materials. c. INSTITUTIONAL SUBSCRIPTION: ...

  14. Estimated amount of 24-hour urine sodium excretion is positively correlated with stomach and breast cancer prevalence in Korea.

    PubMed

    Park, Jung Hwan; Kim, Yong Chul; Koo, Ho Seok; Oh, Se Won; Kim, Suhnggwon; Chin, Ho Jun

    2014-09-01

    Stomach cancer is one of the most common cancers in Korea. The aim of this study was to identify the association between the prevalence of cancer, particularly stomach cancer, and the amount of 24-hr urine sodium excretion estimated from spot urine specimens. The study included 19,083 subjects who took part in the Korean National Health and Nutritional Examination Survey between 2009 and 2011. The total amount of urine sodium excreted in a 24-hr period was estimated by using two equations based on the values for spot urine sodium and creatinine. In subjects who had an estimated 24-hr urine sodium excretion of more than two standard deviations above the mean (group 2), the prevalence of stomach cancer was higher than in subjects with lower 24-hr sodium excretion (group 1). By using the Tanaka equation to estimate it, the prevalence of stomach cancer was 0.6% (114/18,331) in group 1, whereas it was 1.6% (9/568) in group 2 (P=0.006). By using the Korean equation, the prevalence was 0.6% (115/18,392) in group 1, and 1.6% in group 2 (8/507) (P=0.010). By using the Tanaka equation, breast cancer in women is more prevalent in group 2 (1.9%, 6/324) than group 1 (0.8%, 78/9,985, P=0.039). Higher salt intake, as defined by the estimated amount of 24-hr urine sodium excretion, is positively correlated with a higher prevalence of stomach or breast cancer in the Korean population.

  15. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    SciTech Connect

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analytical methods employed and is related to [4].

  16. 24-hour human urine and serum profiles of Bisphenol A following ingestion in soup: Individual pharmacokinetic data and emographics

    DOE PAGES

    Teeguarden, Justin G.; Twaddle, Nathan C.; Churchwell, Mona I.; Yang, Xiaoxia; Fisher, Jeffrey W.; Seryak, Liesel M.; Doerge, Daniel R.

    2015-09-01

    Here we present data to evaluate potential absorption of Bisphenol A through non-metabolizing tissues of the upper digestive tract. Concurrent serum and urine concentrations of d6-BPA, and its glucuronide and sulfate conjugates, were measured over a 24 h period in 10 adult male volunteers following ingestion of 30 μg d6-BPA/kg body weight in soup. The pharmacokinetic behavior of BPA and its metabolites in this cohort (rapid absorption, complete elimination, evidence against sublingual absorption) was reported. This Data in Brief article contains the corresponding individual pharmacokinetic data, reports the demographics of the cohort and provides additional details related to the analyticalmore » methods employed and is related to [4].« less

  17. Dietary quality varies according to data collection instrument: a comparison between a food frequency questionnaire and 24-hour recall.

    PubMed

    Rodrigues, Paulo Rogério Melo; de Souza, Rita Adriana Gomes; De Cnop, Mara Lima; Monteiro, Luana Silva; Coura, Camila Pinheiro; Brito, Alessandra Page; Pereira, Rosangela Alves

    2016-02-01

    The objective of this study was to assess the agreement between the Brazilian Healthy Eating Index - Revised (BHEI-R), estimated by a food frequency questionnaire (FFQ) and multiple 24-hour recalls (24h-R). The Wilcoxon paired test, partial correlations (PC), intraclass correlation coefficient (ICC), and Bland-Altman method were used. The total BHEI-R scores and its components ("total fruits", "whole fruits", "total vegetables", "integral cereals", "saturated fat", "sodium", and "energy intake derived from solid fat, added sugar, and alcoholic beverages") were statistically different, with the ICC and PC indicating poor concordance and correlation. The mean concordance estimated for the total BHEI-R and its components varied from 68% for "integral cereals" to 147% for "whole fruits". The suitable concordance limits were violated for most of the components of the BHEI-R. Poor concordance was observed between the BHEI-R estimated by the FFQ and by multiple 24h-R, which indicated a strong reliability of the BHEI-R on the instrument used to collect information on food consumption. PMID:26910251

  18. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  19. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  20. Urine collection device

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

  1. Estimating the Population Distribution of Usual 24-Hour Sodium Excretion from Timed Urine Void Specimens Using a Statistical Approach Accounting for Correlated Measurement Errors1234

    PubMed Central

    Wang, Chia-Yih; Carriquiry, Alicia L; Chen, Te-Ching; Loria, Catherine M; Pfeiffer, Christine M; Liu, Kiang; Sempos, Christopher T; Perrine, Cria G; Cogswell, Mary E

    2015-01-01

    Background: High US sodium intake and national reduction efforts necessitate developing a feasible and valid monitoring method across the distribution of low-to-high sodium intake. Objective: We examined a statistical approach using timed urine voids to estimate the population distribution of usual 24-h sodium excretion. Methods: A sample of 407 adults, aged 18–39 y (54% female, 48% black), collected each void in a separate container for 24 h; 133 repeated the procedure 4–11 d later. Four timed voids (morning, afternoon, evening, overnight) were selected from each 24-h collection. We developed gender-specific equations to calibrate total sodium excreted in each of the one-void (e.g., morning) and combined two-void (e.g., morning + afternoon) urines to 24-h sodium excretion. The calibrated sodium excretions were used to estimate the population distribution of usual 24-h sodium excretion. Participants were then randomly assigned to modeling (n = 160) or validation (n = 247) groups to examine the bias in estimated population percentiles. Results: Median bias in predicting selected percentiles (5th, 25th, 50th, 75th, 95th) of usual 24-h sodium excretion with one-void urines ranged from −367 to 284 mg (−7.7 to 12.2% of the observed usual excretions) for men and −604 to 486 mg (−14.6 to 23.7%) for women, and with two-void urines from −338 to 263 mg (−6.9 to 10.4%) and −166 to 153 mg (−4.1 to 8.1%), respectively. Four of the 6 two-void urine combinations produced no significant bias in predicting selected percentiles. Conclusions: Our approach to estimate the population usual 24-h sodium excretion, which uses calibrated timed-void sodium to account for day-to-day variation and covariance between measurement errors, produced percentile estimates with relatively low biases across low-to-high sodium excretions. This may provide a low-burden, low-cost alternative to 24-h collections in monitoring population sodium intake among healthy young adults and

  2. Copper urine test (image)

    MedlinePlus

    The copper urine test is performed by collecting urine at specific times for a 24-hour period. The urine is tested for the amount of copper present. The copper urine test is used to determine the presence of Wilson ...

  3. Urinary excretion of sodium, potassium, and chloride, but not iodine, varies by timing of collection in a 24-hour calibration study.

    PubMed

    Wang, Chia-Yih; Cogswell, Mary E; Loria, Catherine M; Chen, Te-Ching; Pfeiffer, Christine M; Swanson, Christine A; Caldwell, Kathleen L; Perrine, Cria G; Carriquiry, Alicia L; Liu, Kiang; Sempos, Christopher T; Gillespie, Cathleen D; Burt, Vicki L

    2013-08-01

    Because of the logistic complexity, excessive respondent burden, and high cost of conducting 24-h urine collections in a national survey, alternative strategies to monitor sodium intake at the population level need to be evaluated. We conducted a calibration study to assess the ability to characterize sodium intake from timed-spot urine samples calibrated to a 24-h urine collection. In this report, we described the overall design and basic results of the study. Adults aged 18-39 y were recruited to collect urine for a 24-h period, placing each void in a separate container. Four timed-spot specimens (morning, afternoon, evening, and overnight) and the 24-h collection were analyzed for sodium, potassium, chloride, creatinine, and iodine. Of 481 eligible persons, 407 (54% female, 48% black) completed a 24-h urine collection. A subsample (n = 133) collected a second 24-h urine 4-11 d later. Mean sodium excretion was 3.54 ± 1.51 g/d for males and 3.09 ± 1.26 g/d for females. Sensitivity analysis excluding those who did not meet the expected creatinine excretion criterion showed the same results. Day-to-day variability for sodium, potassium, chloride, and iodine was observed among those collecting two 24-h urine samples (CV = 16-29% for 24-h urine samples and 21-41% for timed-spot specimens). Among all race-gender groups, overnight specimens had larger volumes (P < 0.01) and lower sodium (P < 0.01 to P = 0.26), potassium (P < 0.01), and chloride (P < 0.01) concentrations compared with other timed-spot urine samples, although the differences were not always significant. Urine creatinine and iodine concentrations did not differ by the timing of collection. The observed day-to-day and diurnal variations in sodium excretion illustrate the importance of accounting for these factors when developing calibration equations from this study.

  4. Agreement between 24-hour salt ingestion and sodium excretion in a controlled environment.

    PubMed

    Lerchl, Kathrin; Rakova, Natalia; Dahlmann, Anke; Rauh, Manfred; Goller, Ulrike; Basner, Mathias; Dinges, David F; Beck, Luis; Agureev, Alexander; Larina, Irina; Baranov, Victor; Morukov, Boris; Eckardt, Kai-Uwe; Vassilieva, Galina; Wabel, Peter; Vienken, Jörg; Kirsch, Karl; Johannes, Bernd; Krannich, Alexander; Luft, Friedrich C; Titze, Jens

    2015-10-01

    Accurately collected 24-hour urine collections are presumed to be valid for estimating salt intake in individuals. We performed 2 independent ultralong-term salt balance studies lasting 105 (4 men) and 205 (6 men) days in 10 men simulating a flight to Mars. We controlled dietary intake of all constituents for months at salt intakes of 12, 9, and 6 g/d and collected all urine. The subjects' daily menus consisted of 27 279 individual servings, of which 83.0% were completely consumed, 16.5% completely rejected, and 0.5% incompletely consumed. Urinary recovery of dietary salt was 92% of recorded intake, indicating long-term steady-state sodium balance in both studies. Even at fixed salt intake, 24-hour urine collection for sodium excretion (UNaV) showed infradian rhythmicity. We defined a ±25 mmol deviation from the average difference between recorded sodium intake and UNaV as the prediction interval to accurately classify a 3-g difference in salt intake. Because of the biological variability in UNaV, only every other daily urine sample correctly classified a 3-g difference in salt intake (49%). By increasing the observations to 3 consecutive 24-hour collections and sodium intakes, classification accuracy improved to 75%. Collecting seven 24-hour urines and sodium intake samples improved classification accuracy to 92%. We conclude that single 24-hour urine collections at intakes ranging from 6 to 12 g salt per day were not suitable to detect a 3-g difference in individual salt intake. Repeated measurements of 24-hour UNaV improve precision. This knowledge could be relevant to patient care and the conduct of intervention trials.

  5. Urine collection apparatus. [feminine hygiene

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females comprises an interface body with an interface surface for engagement with the user's body. The interface body comprises a forward portion defining a urine-receiving bore which has an inlet in the interface surface adapted to be disposed in surrounding relation to the urethral opening of the user. The interface body also has a rear portion integrally adjoining the forward portion and a non-invasive vaginal seal on the interface surface for sealing the vagina of the user from communication with the urine-receiving bore. An absorbent pad is removably supported on the interface body and extends laterally therefrom. A garment for supporting the urine collection is also disclosed.

  6. Electronic Dietary Intake Assessment (e-DIA): Comparison of a Mobile Phone Digital Entry App for Dietary Data Collection With 24-Hour Dietary Recalls

    PubMed Central

    O'Connor, Sarah; Giannelli, Valentina; Yap, Megan LH; Tang, Lie Ming; Roy, Rajshri; Louie, Jimmy Chun Yu; Hebden, Lana; Kay, Judy; Allman-Farinelli, Margaret

    2015-01-01

    Background The electronic Dietary Intake Assessment (e-DIA), a digital entry food record mobile phone app, was developed to measure energy and nutrient intake prospectively. This can be used in monitoring population intakes or intervention studies in young adults. Objective The objective was to assess the relative validity of e-DIA as a dietary assessment tool for energy and nutrient intakes using the 24-hour dietary recall as a reference method. Methods University students aged 19 to 24 years recorded their food and drink intake on the e-DIA for five days consecutively and completed 24-hour dietary recalls on three random days during this 5-day study period. Mean differences in energy, macro-, and micronutrient intakes were evaluated between the methods using paired t tests or Wilcoxon signed-rank tests, and correlation coefficients were calculated on unadjusted, energy-adjusted, and deattenuated values. Bland-Altman plots and cross-classification into quartiles were used to assess agreement between the two methods. Results Eighty participants completed the study (38% male). No significant differences were found between the two methods for mean intakes of energy or nutrients. Deattenuated correlation coefficients ranged from 0.55 to 0.79 (mean 0.68). Bland-Altman plots showed wide limits of agreement between the methods but without obvious bias. Cross-classification into same or adjacent quartiles ranged from 75% to 93% (mean 85%). Conclusions The e-DIA shows potential as a dietary intake assessment tool at a group level with good ranking agreement for energy and all nutrients. PMID:26508282

  7. 24-Hour Relativistic Bit Commitment

    NASA Astrophysics Data System (ADS)

    Verbanis, Ephanielle; Martin, Anthony; Houlmann, Raphaël; Boso, Gianluca; Bussières, Félix; Zbinden, Hugo

    2016-09-01

    Bit commitment is a fundamental cryptographic primitive in which a party wishes to commit a secret bit to another party. Perfect security between mistrustful parties is unfortunately impossible to achieve through the asynchronous exchange of classical and quantum messages. Perfect security can nonetheless be achieved if each party splits into two agents exchanging classical information at times and locations satisfying strict relativistic constraints. A relativistic multiround protocol to achieve this was previously proposed and used to implement a 2-millisecond commitment time. Much longer durations were initially thought to be insecure, but recent theoretical progress showed that this is not so. In this Letter, we report on the implementation of a 24-hour bit commitment solely based on timed high-speed optical communication and fast data processing, with all agents located within the city of Geneva. This duration is more than 6 orders of magnitude longer than before, and we argue that it could be extended to one year and allow much more flexibility on the locations of the agents. Our implementation offers a practical and viable solution for use in applications such as digital signatures, secure voting and honesty-preserving auctions.

  8. 24-Hour Academic Libraries: Adjusting to Change

    ERIC Educational Resources Information Center

    Bowman, Adam C.

    2013-01-01

    The purpose of this study was to explore the adaptive measures that academic libraries perform when implementing and operating a 24-hour schedule. Five in-depth interviews were conducted with current managerial-level librarians at 24-hour academic libraries. The exploratory interviews revealed similar measures for security, budgeting, employee…

  9. The 24-Hour Mathematical Modeling Challenge

    ERIC Educational Resources Information Center

    Galluzzo, Benjamin J.; Wendt, Theodore J.

    2015-01-01

    Across the mathematics curriculum there is a renewed emphasis on applications of mathematics and on mathematical modeling. Providing students with modeling experiences beyond the ordinary classroom setting remains a challenge, however. In this article, we describe the 24-hour Mathematical Modeling Challenge, an extracurricular event that exposes…

  10. Urinary {alpha}{sub 1}-microglobulin, {beta}{sub 2}-microglobulin, and retinol-binding protein levels in general populations in Japan with references to cadmium in urine, blood, and 24-hour food duplicates

    SciTech Connect

    Ikeda, Masayuki; Moon, Chan-Seok; Zhang, Zuo-Wen

    1995-07-01

    Possible cadmium (Cd) exposure-associated changes in urinary levels of low-molecular-weight proteins were studied in nonsmoking and nondrinking female members of the general Japanese population (378 subjects with no known occupational heavy metal exposure) who lived at 19 study sites (all without any known environmental heavy metal pollution) in 13 prefectures throughout Japan. The external Cd dose was evaluated in terms of daily Cd intake via food (Cd-F), whereas Cd levels in blood (Cd-B) and urine (Cd-U) were taken as internal dose indicators. When the subjects were classified according to Cd-F into three groups with {open_quotes}low{close_quotes} (20.4 {mu}g/day as a geometric mean of 97 women), {open_quotes}middle{close_quotes} (35.0 {mu}g/day, 120 women) and {open_quotes}high{close_quotes} (67.0 {mu}g/day, 66 women) exposure, both Cd-B and Cd-U increased in parallel with the changes in Cd-F. However, there were no dose-dependent changes in {beta}{sub 2}-microglobulin or retinol-binding protein levels in urine. {alpha}{sub 1}-Microglobulin levels appeared to increase, but the distribution of the cases above the two cutoff levels of 9.6 and 15.8 {mu}g/mg creatinine among the three Cd-F groups did not show any bias. Overall, it was concluded that there was no apparent Cd exposure-associated elevation in urinary low-molecular-weight protein levels in the study population. 41 refs., 2 figs., 7 tabs.

  11. Gonadotropin determinations in times 3-hour urine collections during the menstrual cycle and LHRH testing.

    PubMed

    Beitins, I Z; O'Loughlin, K; Ostrea, T; McArthur, J W

    1976-07-01

    The usefulness of timed 3-hour urine collections as a substitute for serum gonadotropin (LH and FSH) determinations during the menstrual cycle and during LHRH testing was examined. The timing of the 3-hour urine collection is not important in mature individuals, since no significant temporal trend was found when aliquots were collected every 3 hours throughout two 24-hour periods in one mature woman. Good correlation was found between serum LH and FSH concentrations and the quantity of LH and FSH in timed 3-hour urine specimens throughout normal, ovulatory menstrual cycles in two women. Studies before and during 51 LHRH stimulation tests in normal men, children, and women during different phases of the menstrual cycle and in patients with a variety of hypothalamic-pituitary-gonadal axis disorders were performed. There was good correlation between the quantity of the gonadotropins in time 3-hour urine collections and the mean serum LH and FSH concentrations before and during the LHRH test. The "response area" for serum LH and FSH also correlated well with the amounts of LH and FSH in the urine collected during this period. Therefore, the timed 3-hour urine collection for gonadotropin estimation provides a simple, accurate method for the integration of fluctuating serum concentrations of LH and FSH during such instances of physiologic variability as the menstrual cycle and LHRH stimulation tests.

  12. Gonadotropin determinations in timed 3-hour urine collections during the menstrual cycle and LHRH testing.

    PubMed

    Beitins, I Z; O'loughlin, K; Ostrea, T; Mcarthur, J W

    1976-07-01

    Gonadotropin determinations in timed 3-hour urine collections during the menstrual cycle and luteinizing hormone-releasing hormone (LHRH) testing are reported. No marked temporal trend was seen when urine aliquots were collected every 3 hours throughout 2 24-hour periods in 1 mature woman. A good correlation (p less than .001) was seen between serum LH and follicle stimulation hormone (FSH) concentrations and the quantity ovulatory menstrual cycles in 2 women. A good correlation (p less than .001) was also seen between the quantity of the gonadotropins in timed 3-hour urine collections and serum LH and FSH concentrations before and during the LHRH test in 51 normal men, women, and children and in patients with hypothalamic-pituitary-gonadal axis disorders. The "response area" for serum LH and FSH also correlated well (p less than .001) with the LH and FSH in the urine collected. It is concluded that the timed 3-hour urine collection for gonadotropin estimation provides a simple, accurate method for the integration of fluctuating serum concentrations of LH and FSH during such instances of physiologic variability as the menstrual cycle and LHRH stimulation tests.

  13. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Preparing for urine collection. 26.105 Section 26.105... Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer... tamper with or adulterate his or her urine specimen. The collector shall ensure that all...

  14. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Preparing for urine collection. 26.105 Section 26.105... Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary outer... tamper with or adulterate his or her urine specimen. The collector shall ensure that all...

  15. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  16. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary...

  17. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used...

  18. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary...

  19. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used...

  20. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used...

  1. 10 CFR 26.105 - Preparing for urine collection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Preparing for urine collection. 26.105 Section 26.105 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.105 Preparing for urine collection. (a) The collector shall ask the donor to remove any unnecessary...

  2. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used...

  3. 10 CFR 26.107 - Collecting a urine specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen. 26.107 Section 26.107 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.107 Collecting a urine specimen. (a) The collector shall direct the donor to go into the room or stall used...

  4. Human prolactin - 24-hour pattern with increased release during sleep.

    NASA Technical Reports Server (NTRS)

    Sassin, J. F.; Weitzman, E. D.; Kapen, S.; Frantz, A. G.

    1972-01-01

    Human prolactin was measured in plasma by radioimmunoassay at 20-minute intervals for a 24-hour period in each of six normal adults, whose sleep-wake cycles were monitored polygraphically. A marked diurnal variation in plasma concentrations was demonstrated, with highest values during sleep. Periods of episodic release occurred throughout the 24 hours.

  5. Urine Protein and Urine Protein to Creatinine Ratio

    MedlinePlus

    ... limited. Home Visit Global Sites Search Help? Urine Protein and Urine Protein to Creatinine Ratio Share this page: Was this page helpful? Also known as: 24-Hour Urine Protein; Urine Total Protein; Urine Protein to Creatinine Ratio; ...

  6. Measurement error corrected sodium and potassium intake estimation using 24-hour urinary excretion.

    PubMed

    Huang, Ying; Van Horn, Linda; Tinker, Lesley F; Neuhouser, Marian L; Carbone, Laura; Mossavar-Rahmani, Yasmin; Thomas, Fridtjof; Prentice, Ross L

    2014-02-01

    Epidemiological studies of the association of sodium and potassium intake with cardiovascular disease risk have almost exclusively relied on self-reported dietary data. Here, 24-hour urinary excretion assessments are used to correct the dietary self-report data for measurement error under the assumption that 24-hour urine recovery provides a biomarker that differs from usual intake according to a classical measurement model. Under this assumption, dietary self-reports underestimate sodium by 0% to 15%, overestimate potassium by 8% to 15%, and underestimate sodium/potassium ratio by ≈20% using food frequency questionnaires, 4-day food records, or three 24-hour dietary recalls in Women's Health Initiative studies. Calibration equations are developed by linear regression of log-transformed 24-hour urine assessments on corresponding log-transformed self-report assessments and several study subject characteristics. For each self-report method, the calibration equations turned out to depend on race and age and strongly on body mass index. After adjustment for temporal variation, calibration equations using food records or recalls explained 45% to 50% of the variation in (log-transformed) 24-hour urine assessments for sodium, 60% to 70% of the variation for potassium, and 55% to 60% of the variation for sodium/potassium ratio. These equations may be suitable for use in epidemiological disease association studies among postmenopausal women. The corresponding signals from food frequency questionnaire data were weak, but calibration equations for the ratios of sodium and potassium/total energy explained ≈35%, 50%, and 45% of log-biomarker variation for sodium, potassium, and their ratio, respectively, after the adjustment for temporal biomarker variation and may be suitable for cautious use in epidemiological studies. Clinical Trial Registration- URL: www.clinicaltrials.gov. Unique identifier: NCT00000611.

  7. Effects of separate urine collection on advanced nutrient removal processes.

    PubMed

    Wilsenach, J A; van Loosdrecht, M C M

    2004-02-15

    Municipal wastewater contains a mixture of minerals from different origins. Urine contributes 80% of the nitrogen (N) and 45% of the phosphate (P) load in wastewater. Effects of separate urine collection on BNR processes were evaluated by using a simulation model for an existing state-of-the-art biological nutrient removal process. It was found that increasing urine separation efficiency leads to lower nitrate effluent concentrations, while ammonium and phosphorus concentrations remain more or less the same. The improved nitrate effluent quality is most notable up to 50-60% urine separation. Urine separation allows primary sedimentation without an increase in the nitrate effluent concentration. Furthermore, urine separation increases the potential treatment capacity for raw and settled wastewater by 20% and 60%, respectively. Urine separation provides options for increasing the lifetime of existing treatment works.

  8. Development testing of a shuttle urine collection system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Flight tests conducted in December 1973 demonstrated the ability of an unisexual urine collection subsystem to function in a zero-g environment. The urinal, which could be adjusted with three degrees of freedom, accommodated 16 female test subjects with a wide range of stature, as well as five male test subjects. The urinal was in intimate contact with the female and was contoured to form an effective air seal at the periphery. When positioned 2-4 inches forward, the urinal could be used for male collection and contact was not required.

  9. Estimation of 24-Hour Intraocular Pressure Peak Timing and Variation Using a Contact Lens Sensor

    PubMed Central

    Liu, John H. K.; Mansouri, Kaweh; Weinreb, Robert N.

    2015-01-01

    Purpose To compare estimates of 24-hour intraocular pressure (IOP) peak timing and variation obtained using a contact lens sensor (CLS) and using a pneumatonometer. Methods Laboratory data collected from 30 healthy volunteers (ages, 20-66 years) in a randomized, controlled clinical trial were analyzed. Participants were housed for 24 hours in a sleep laboratory. One randomly selected right or left eye was fitted with a CLS that monitored circumferential curvature in the corneoscleral region related to the change of IOP. Electronic output signals of 30 seconds were averaged and recorded every 5 minutes. In the contralateral eye, habitual IOP measurements were taken using a pneumatonometer once every two hours. Simulated 24-hour rhythms in both eyes were determined by cosinor fitting. Simulated peak timings (acrophases) and simulated data variations (amplitudes) were compared between the paired eyes. Results Bilateral change patterns of average 24-hour data for the group were in parallel. The simulated peak timing in the CLS fitted eye occurred at 4:44 AM ± 210 min (mean ± SD) and the IOP peak timing in the contralateral eye at 4:11 AM ± 120 min (P=0.256, Wilcoxon signed-rank test). There was no significant correlation between the simulated data variations in the paired eyes (P=0.820, linear regression). Conclusions The 24-hour CLS data showed a simulated peak timing close to the 24-hour IOP peak timing obtained using the pneumatonometer. However, the simulated variations of 24-hour data in the paired eyes were not correlated. Estimated 24-hour IOP rhythms using the two devices should not be considered interchangeable. PMID:26076472

  10. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  11. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  12. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  13. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  14. 29 CFR 785.21 - Less than 24-hour duty.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be on duty for less than 24 hours is working even though he is permitted to sleep or engage in other... specified hours is working even though she is permitted to sleep when not busy answering calls. It makes...

  15. Managing sleep and wakefulness in a 24-hour world

    PubMed Central

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work–social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns. PMID:23957268

  16. Managing sleep and wakefulness in a 24-hour world.

    PubMed

    Coveney, Catherine M

    2014-01-01

    This article contributes to literature on the sociology of sleep by exploring the sleeping practices and subjective sleep experiences of two social groups: shift workers and students. It draws on data, collected in the UK from 25 semi-structured interviews, to discuss the complex ways in which working patterns and social activities impact upon experiences and expectations of sleep in our wired awake world. The data show that, typically, sleep is valued and considered to be important for health, general wellbeing, appearance and physical and cognitive functioning. However, sleep time is often cut back on in favour of work demands and social activities. While shift workers described their efforts to fit in an adequate amount of sleep per 24-hour period, for students, the adoption of a flexible sleep routine was thought to be favourable for maintaining a work-social life balance. Collectively, respondents reported using a wide range of strategies, techniques, technologies and practices to encourage, overcome or delay sleep(iness) and boost, promote or enhance wakefulness/alertness at socially desirable times. The analysis demonstrates how social context impacts not only on how we come to think about sleep and understand it, but also how we manage or self-regulate our sleeping patterns.

  17. Estimate of dietary phosphorus intake using 24-h urine collection.

    PubMed

    Morimoto, Yuuka; Sakuma, Masae; Ohta, Hiroyuki; Suzuki, Akitsu; Matsushita, Asami; Umeda, Minako; Ishikawa, Makoto; Taketani, Yutaka; Takeda, Eiji; Arai, Hidekazu

    2014-07-01

    Increases in serum phosphorus levels and dietary phosphorus intake induces vascular calcification, arterial sclerosis and cardiovascular diseases. Limiting phosphorus intake is advisable, however, no assessment methods are capable of estimating dietary phosphorus intake. We hypothesized that urinary phosphorus excretion can be translated into estimation of dietary phosphorus intake, and we evaluated whether a 24-h urine collection method could estimate dietary phosphorus intake. Thirty two healthy subjects were recruited for this study. Subjects collected urine samples over 24 h and weighed dietary records. We calculated dietary protein intake and phosphorus intake from dietary records and urine collection, and investigated associations between the two methods in estimating protein and phosphorus intake. Significant positive correlations were observed between dietary records and UC for protein and phosphorus intake. The average intakes determined from dietary records were significantly higher than from urine collection for both protein and phosphorus. There was a significant positive correlation between both the phosphorus and protein difference in dietary records and urine collection. The phosphorus-protein ratio in urine collection was significantly higher than in dietary records. Our data indicated that the 24-h urine collection method can estimate the amount of dietary phosphorus intake, and the results were superior to estimation by weighed dietary record.

  18. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  19. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation.

    PubMed

    Taber, Michael J; Hartley, Geoffrey L; McGarr, Gregory W; Zaharieva, Dessi; Basset, Fabien A; Hynes, Zach; Haman, Francois; Pinet, Bernard M; DuCharme, Michel B; Cheung, Stephen S

    2016-01-01

    Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (T c) and cognitive test battery (CTB) performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature). Participants (recruited from those who have regular occupational exposure to cold) were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease T c after exposure and to eliminate the typical 0.5-1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance. PMID:27478839

  20. Cognitive Performance during a 24-Hour Cold Exposure Survival Simulation

    PubMed Central

    Hartley, Geoffrey L.; Zaharieva, Dessi; Basset, Fabien A.; Hynes, Zach

    2016-01-01

    Survivor of a ship ground in polar regions may have to wait more than five days before being rescued. Therefore, the purpose of this study was to explore cognitive performance during prolonged cold exposure. Core temperature (Tc) and cognitive test battery (CTB) performance data were collected from eight participants during 24 hours of cold exposure (7.5°C ambient air temperature). Participants (recruited from those who have regular occupational exposure to cold) were instructed that they could freely engage in minimal exercise that was perceived to maintaining a tolerable level of thermal comfort. Despite the active engagement, test conditions were sufficient to significantly decrease Tc after exposure and to eliminate the typical 0.5–1.0°C circadian rise and drop in core temperature throughout a 24 h cycle. Results showed minimal changes in CTB performance regardless of exposure time. Based on the results, it is recommended that survivors who are waiting for rescue should be encouraged to engage in mild physical activity, which could have the benefit of maintaining metabolic heat production, improve motivation, and act as a distractor from cold discomfort. This recommendation should be taken into consideration during future research and when considering guidelines for mandatory survival equipment regarding cognitive performance. PMID:27478839

  1. Insights about serum sodium behavior after 24 hours of continuous renal replacement therapy

    PubMed Central

    Romano, Thiago Gomes; Martins, Cassia Pimenta Barufi; Mendes, Pedro Vitale; Besen, Bruno Adler Maccagnan Pinheiro; Zampieri, Fernando Godinho; Park, Marcelo

    2016-01-01

    Objective The aim of this study was to investigate the clinical and laboratorial factors associated with serum sodium variation during continuous renal replacement therapy and to assess whether the perfect admixture formula could predict 24-hour sodium variation. Methods Thirty-six continuous renal replacement therapy sessions of 33 patients, in which the affluent prescription was unchanged during the first 24 hours, were retrieved from a prospective collected database and then analyzed. A mixed linear model was performed to investigate the factors associated with large serum sodium variations (≥ 8mEq/L), and a Bland-Altman plot was generated to assess the agreement between the predicted and observed variations. Results In continuous renal replacement therapy 24-hour sessions, SAPS 3 (p = 0.022) and baseline hypernatremia (p = 0.023) were statistically significant predictors of serum sodium variations ≥ 8mEq/L in univariate analysis, but only hypernatremia demonstrated an independent association (β = 0.429, p < 0.001). The perfect admixture formula for sodium prediction at 24 hours demonstrated poor agreement with the observed values. Conclusions Hypernatremia at the time of continuous renal replacement therapy initiation is an important factor associated with clinically significant serum sodium variation. The use of 4% citrate or acid citrate dextrose - formula A 2.2% as anticoagulants was not associated with higher serum sodium variations. A mathematical prediction for the serum sodium concentration after 24 hours was not feasible. PMID:27410407

  2. Aldosterone-to-Renin Ratio Is Associated With Reduced 24-Hour Heart Rate Variability and QTc Prolongation in Hypertensive Patients

    PubMed Central

    Grübler, Martin R.; Kienreich, Katharina; Gaksch, Martin; Verheyen, Nicolas; Hartaigh, Bríain Ó.; Fahrleitner-Pammer, Astrid; März, Winfried; Schmid, Johannes; Oberreither, Eva-Maria; Wetzel, Julia; Catena, Cristiana; Sechi, Leonardo A.; Pieske, Burkert; Tomaschitz, Andreas; Pilz, Stefan

    2016-01-01

    Abstract Aldosterone is considered to exert direct effects on the myocardium and the sympathetic nervous system. Both QT time and heart rate (HR) variability (HRV) are considered to be markers of arrhythmic risk and autonomous dysregulation. In this study, we investigated the associations between aldosterone, QT time, and HRV in patients with arterial hypertension. We recruited 477 hypertensive patients (age: 60.2 ± 10.2 years; 52.3% females) with a mean systolic/diastolic 24-hour ambulatory blood pressure monitoring (ABPM) value of 128 ± 12.8/77.1 ± 9.2 mmHg and with a median of 2 (IQR: 1–3) antihypertensive agents. Patients were recruited from the outpatient clinic at the Department of Internal Medicine of the Medical University of Graz, Austria. Blood samples, 24-hour HRV derived from 24-hour blood pressure monitoring (ABPM) and ECG's were obtained. Plasma aldosterone and plasma renin concentrations were measured by means of a radioimmunoassay. Twenty-four-hour urine specimens were collected in parallel with ABPM. Mean QTc was 423.3 ± 42.0 milliseconds for males and 434.7 ± 38.3 milliseconds for females. Mean 24H-HR and 24H-HRV was 71.9 ± 9.8 and 10.0 ± 3.6 bpm, respectively. In linear regression analyses adjusted for age, sex, body mass index, ABPM, and current medication, aldosterone to active renin ratio (AARR) was significantly associated with the QTc interval, a marker for cardiac repolarization abnormalities (mean = 426 ± 42.4 milliseconds; β-coefficient = 0.121; P = 0.03) as well as with the 24-hour heart rate variability a surrogate for autonomic dysfunction (median = 9.67 [IQR = 7.38–12.22 bpm]; β-coefficient = −0.133; P = 0.01). In hypertensive patients, AARR is significantly related to QTc prolongation as well as HRV. Further studies investigating the effects of mineralocorticoid receptor blocker and aldosterone synthase inhibitors on QTc and HRV are warranted

  3. 17-Ketosteroids urine test

    MedlinePlus

    ... Philadelphia, PA: Elsevier Saunders; 2014:chap 34. Chernecky CC, Berger BJ. Metyrapone (cortisol) - 24-hour urine. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . ...

  4. The 24 Hours before Hospitalization: Factors Related to Suicide Attempting.

    ERIC Educational Resources Information Center

    Chiles, John A.; And Others

    1986-01-01

    Psychiatric inpatients (N=59) were interviewd concerning psychological and environmental events that occurred in the 24 hours prior to their hospitalization. Suicide attempters were more likely to have used alcohol or marijuana and less likely to have contacted a health care professional than suicide ideators, even when past history of suicide…

  5. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens

    PubMed Central

    Castaneto, Marisol S.; Scheidweiler, Karl B.; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L.; Martin, Thomas M.; Huestis, Marilyn A.

    2014-01-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20,017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1,432 presumptive positive specimens. We analyzed all presumptive positive and 1,069 negative specimens with our qualitative synthetic cannabinoid LC-MS/MS method, which confirmed 290 positive specimens. All 290 positive and 487 randomly-selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date. 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-018 N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1–2434), 5.1 (0.1–1239), 2.0 (0.1–321), 1.1 (0.1–48.6), and 1.1 (0.1–250) μg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although, hydroxyindoles also were observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake. PMID:25231213

  6. Quantitative urine confirmatory testing for synthetic cannabinoids in randomly collected urine specimens.

    PubMed

    Castaneto, Marisol S; Scheidweiler, Karl B; Gandhi, Adarsh; Wohlfarth, Ariane; Klette, Kevin L; Martin, Thomas M; Huestis, Marilyn A

    2015-06-01

    Synthetic cannabinoid intake is an ongoing health issue worldwide, with new compounds continually emerging, making drug testing complex. Parent synthetic cannabinoids are rarely detected in urine, the most common matrix employed in workplace drug testing. Optimal identification of synthetic cannabinoid markers in authentic urine specimens and correlation of metabolite concentrations and toxicities would improve synthetic cannabinoid result interpretation. We screened 20 017 randomly collected US military urine specimens between July 2011 and June 2012 with a synthetic cannabinoid immunoassay yielding 1432 presumptive positive specimens. We analyzed all presumptive positive and 1069 negative specimens with our qualitative synthetic cannabinoid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which confirmed 290 positive specimens. All 290 positive and 487 randomly selected negative specimens were quantified with the most comprehensive urine quantitative LC-MS/MS method published to date; 290 specimens confirmed positive for 22 metabolites from 11 parent synthetic cannabinoids. The five most predominant metabolites were JWH-018 pentanoic acid (93%), JWH-N-hydroxypentyl (84%), AM2201 N-hydroxypentyl (69%), JWH-073 butanoic acid (69%), and JWH-122 N-hydroxypentyl (45%) with 11.1 (0.1-2,434), 5.1 (0.1-1,239), 2.0 (0.1-321), 1.1 (0.1-48.6), and 1.1 (0.1-250) µg/L median (range) concentrations, respectively. Alkyl hydroxy and carboxy metabolites provided suitable biomarkers for 11 parent synthetic cannabinoids; although hydroxyindoles were also observed. This is by far the largest data set of synthetic cannabinoid metabolites urine concentrations from randomly collected workplace drug testing specimens rather than acute intoxications or driving under the influence of drugs. These data improve the interpretation of synthetic cannabinoid urine test results and suggest suitable urine markers of synthetic cannabinoid intake.

  7. Effect of daily oral omeprazole on 24 hour intragastric acidity.

    PubMed Central

    Walt, R P; Gomes, M D; Wood, E C; Logan, L H; Pounder, R E

    1983-01-01

    Twenty four hour intragastric acidity was measured in nine patients with duodenal ulcer before and after one week of treatment with oral omeprazole 30 mg daily, a drug that inhibits gastric secretion by inhibition of parietal cell H+K+ adenosinetriphosphatase (ATPase). Omeprazole virtually eliminated intragastric acidity in all patients: the median 24 hour intragastric pH rose from 1.4 to 5.3 and the mean hourly hydrogen ion activity fell from 38.50 to 1.95 mmol(mEq)/1 (p less than 0.001). This inhibition of 24 hour intragastric acidity is more profound than that previously reported with either cimetidine 1 g daily or ranitidine 300 mg daily. PMID:6407676

  8. [Gastroesophageal reflux during pregnancy: 24-hour esophageal ph monitoring].

    PubMed

    Anton, C; Anton, E; Drug, V; Stanciu, C

    2001-01-01

    Gastroesophageal reflux (GER) occurs in 30-50% of all pregnancies. The progressive rise in plasma progesterone has been suggested as a possible mediator of GER during pregnancy. Recent advances in technology have made it possible to detect GER through monitoring of esophageal pH for prolonged periods, including sleep. 24-hour pH monitoring is the proper method for diagnosing GER in pregnant women. If 24-hour esophageal pH monitoring is to be a useful diagnostic tool, it must reliably discriminate GER patients despite daily variations in distal esophageal acid exposure. To address this issue, we studied 62 women (30 healthy non-pregnant women without GER symptoms and 32 pregnant women with GER symptoms-heartburn, acid regurgitation) with 24-hour esophageal pH monitoring. Intrasubject reproducibility of three pH parameters to discriminate the presence of abnormal acid reflux was determined (DeMeester score, Kaye score, circadian one hour diagram for pH < 4). Each patient was interviewed, using a reliable questionnaire detailing individual habits, life style characteristics and symptoms, at four time points during the first, second, third trimesters of pregnancy and post-partum period. Symptoms of GER are common in pregnancy and although GER rarely endangers maternal or fetal health, it can significantly affect patient comfort and quality of life. We conclude: 1. GER is almost constantly present during pregnancy, increasing with gestational age. 2. The most important pH--parameter is DeMcester score. 3. Heartburn disappear after delivery. 4. 24-hour esophageal pH monitoring is the gold standard for measuring acid exposure and is a reproducible test for the diagnosis of GER in pregnancy.

  9. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  10. A prototype urine collection device for female aircrew

    NASA Technical Reports Server (NTRS)

    Bisson, Roger U.; Delger, Karlyna L.

    1993-01-01

    Women are gaining increased access to small military cockpits. This shift has stimulated the search for practical urine containment and disposal methods for female aircrew. There are no external urine collection devices (UCD) for women that are comfortable, convenient, and leak free. We describe a prototype UCD that begins to meet this need. Materials used to make custom aviator masks were adapted to mold a perineal mask. First, a perineal cast (negative) was used to make a mold (positive). Next, a perineal mask made of wax was formed to fit the positive mold. Finally, a soft, pliable perineal mask was fabricated using the wax model as a guide. The prototype was tested for comfort, fit, and leakage. In the sitting position, less than 5 cc of urine leakage occurred with each 600 cc of urine collected. Comfort was mostly satisfactory, but ambulation was limited and the outlet design could lead to kinking and obstruction. We concluded that a perineal mask may serve as a comfortable and functional external UCD acceptable for use by females in confined environments. Changes are needed to improve comfort, fit, and urine drainage. Integration into cockpits, pressure suits, chemical defense gear, and environments where access to relief facilities is restricted is planned.

  11. Laparoscopic Colon Resections With Discharge Less Than 24 Hours

    PubMed Central

    Ganji, Maedeh; Alam, Shaan E.; Kar, Pran M.

    2013-01-01

    Background and Objectives: A short hospital stay is one of the main advantages of laparoscopic surgery. Previous studies have shown that after a multimodal fast-track process, the hospital length of stay can be shortened to between 2 and 5 days. The objective of this review is to show that the hospital length of stay can, in some cases, be reduced to <24 hours. Methods: This study retrospectively reviews a surgeon's experience with laparoscopic surgery over a 12-month period. Seven patients were discharged home within 24 hours after minimally invasive laparoscopic surgical treatment, following a modified fast-track protocol that was adopted for perioperative care. Results: Of the 7 patients, 4 received laparoscopic right hemicolectomy for malignant disease and 3 underwent sigmoid colectomies for recurrent diverticulitis. The mean hospital stay was 21 hours, 47 minutes; the mean volume of intraoperative fluid (lactated Ringer) was 1850 mL; the mean surgical blood loss was only 74.3 mL; the mean duration of surgery was 118 minutes; and the patients were ambulated and fed a liquid diet after recovery from anesthesia. The reviewed patients had functional gastrointestinal tracts and were agreeable to the timing of discharge. On the follow-up visit, they showed no adverse consequences such as bleeding, infection, or anastomotic leak. Conclusion: Laparoscopic colon surgery that incorporated multimodal perioperative care allowed patients to be discharged within the first 24 hours. Careful postoperative outpatient follow-up is important in monitoring complications such as anastomotic leak, which may not present until postoperative day 5. PMID:23925012

  12. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What form is used to document a DOT urine... in DOT Urine Collections § 40.45 What form is used to document a DOT urine collection? (a) The Federal Drug Testing Custody and Control Form (CCF) must be used to document every urine...

  13. Pulmonary function in mechanically-ventilated patients during 24-hour use of a hygroscopic condensor humidifier.

    PubMed

    MacIntyre, N R; Anderson, H R; Silver, R M; Schuler, F R; Coleman, R E

    1983-11-01

    Hygroscopic condensor humidifiers (HCH) are reportedly capable of humidifying even the driest of ventilator source gases with at least 30 mg H2O/liter of ventilation. To assess the adequacy of the HCH during mechanical ventilation, we studied 26 patients over a 72-hour period (alternating 24-hour periods of humidification by a conventional cascade and the HCH). In these patients, we found no significant difference in static lung compliance, airway resistance, PaO2, and PaCO2 on either system. Additionally, estimates of sputum volume (over a four-hour collection period) and clearance of aerosolized 99mTc labelled DTPA (in five of these patients) also showed no significant differences between the two systems. We conclude that the HCH is capable of supplying necessary heat and moisture to most mechanically-ventilated patients for at least a period of 24 hours.

  14. Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence

    PubMed Central

    Malik, Rena D.; Cohn, Joshua A.; Fedunok, Pauline A.; Chung, Doreen E.; Bales, Gregory T.

    2016-01-01

    ABSTRACT Purpose: Decision-making regarding surgery for post-prostatectomy incontinence (PPI) is challenging. The 24-hour pad weight test is commonly used to objectively quantify PPI. However, pad weight may vary based upon activity level. We aimed to quantify variability in pad weights based upon patient-reported activity. Materials and Methods: 25 patients who underwent radical prostatectomy were prospectively enrolled. All patients demonstrated clinical stress urinary incontinence without clinical urgency urinary incontinence. On three consecutive alternating days, patients submitted 24-hour pad weights along with a short survey documenting activity level and number of pads used. Results: Pad weights collected across the three days were well correlated to the individual (ICC 0.85 (95% CI 0.74–0.93), p<0.001). The mean difference between the minimum pad weight leakage and maximum leakage per patient was 133.4g (95% CI 80.4–186.5). The mean increase in 24-hour leakage for a one-point increase in self-reported activity level was 118.0g (95% CI 74.3–161.7, p<0.001). Pad weights also varied significantly when self-reported activity levels did not differ (mean difference 51.2g (95% CI 30.3–72.1), p<0.001). Conclusions: 24-hour pad weight leakage may vary significantly on different days of collection. This variation is more pronounced with changes in activity level. Taking into account patient activity level may enhance the predictive value of pad weight testing. PMID:27256187

  15. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false What materials are used to collect urine specimens... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT drug test, you must use a collection kit meeting the requirements of Appendix A of this part....

  16. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false What materials are used to collect urine specimens... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT drug test, you must use a collection kit meeting the requirements of appendix A of this part....

  17. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false What materials are used to collect urine specimens... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT drug test, you must use a collection kit meeting the requirements of Appendix A of this part....

  18. 49 CFR 40.49 - What materials are used to collect urine specimens?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What materials are used to collect urine specimens... in DOT Urine Collections § 40.49 What materials are used to collect urine specimens? For each DOT drug test, you must use a collection kit meeting the requirements of Appendix A of this part....

  19. A practical approach to using spot urine protein/creatinine ratios for assessing proteinuria in pregnancy

    PubMed Central

    Marnoch, Catherine A; Larson, Lucia; Weitzen, Sherry; Phipps, Maureen G; Sung, C James; Powrie, Raymond O

    2008-01-01

    Objective: The aim of this study is to assess the diagnostic accuracy of the spot urine protein/creatinine ratio compared with the 24-hour urine protein in pregnancy. Study Design: In this prospective cohort study of inpatient pregnant women, the protein/creatinine ratio and dipstick protein were assessed from a single urine sample collected at the start of the 24-hour urine. Both tests were compared with the 24-hour urine protein for correlation and test characteristics. Results: In the 196 specimens analysed, we found a strong correlation between the spot urine protein/creatinine ratio and 24-hour urine protein (r 2 = 0.78, P < 0.01). A protein/creatinine ratio <0.1 ruled out significant proteinuria (≥300 mg/day) with sensitivity and negative predictive value 100%. A protein/creatinine ratio ≥0.4 detected significant proteinuria (specificity and positive predictive value of 100%). A protein/creatinine ratio ≥4.6 had a specificity and positive predictive value of 100% for detecting severe proteinuria (≥5000 mg/day). Urine dipsticks correlated poorly with the 24-hour urine protein (r 2 = 0.40, P = 0.826). Nineteen percent of dipsticks reading nil or trace were false-negative results. Conclusion: The spot urine protein/creatinine ratio correlated well with the 24-hour urine protein and performed better than the urine dipsticks. Significant proteinuria in pregnancy was excluded if the protein/creatinine ratio was <0.1 and identified when it was ≥0.4. PMID:27630741

  20. Exercising in the Fasted State Reduced 24-Hour Energy Intake in Active Male Adults

    PubMed Central

    Deitrick, Ronald W.; Hillman, Angela R.

    2016-01-01

    The effect of fasting prior to morning exercise on 24-hour energy intake was examined using a randomized, counterbalanced design. Participants (12 active, white males, 20.8 ± 3.0 years old, VO2max: 59.1 ± 5.7 mL/kg/min) fasted (NoBK) or received breakfast (BK) and then ran for 60 minutes at 60%  VO2max. All food was weighed and measured for 24 hours. Measures of blood glucose and hunger were collected at 5 time points. Respiratory quotient (RQ) was measured during exercise. Generalized linear mixed models and paired sample t-tests examined differences between the conditions. Total 24-hour (BK: 19172 ± 4542 kJ versus NoBK: 15312 ± 4513 kJ; p < 0.001) and evening (BK: 12265 ± 4278 kJ versus NoBK: 10833 ± 4065; p = 0.039) energy intake and RQ (BK: 0.90 ± 0.03 versus NoBK: 0.86 ± 0.03; p < 0.001) were significantly higher in BK than NoBK. Blood glucose was significantly higher in BK than NoBK before exercise (5.2 ± 0.7 versus 4.5 ± 0.6 mmol/L; p = 0.025). Hunger was significantly lower for BK than NoBK before exercise, after exercise, and before lunch. Blood glucose and hunger were not associated with energy intake. Fasting before morning exercise decreased 24-hour energy intake and increased fat oxidation during exercise. Completing exercise in the morning in the fasted state may have implications for weight management. PMID:27738523

  1. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  2. [Necessity of a 24-hour system of blood transfusion testing].

    PubMed

    Kishimoto, Yuji

    2003-01-01

    The preventive effects of a 24-hour system of blood transfusion testing on mistyping of transfused blood was examined. Blood transfusion tests have been performed by blood transfusion technologists during working hours and by physicians at other times. In March 2000, we introduced a system in which technologists perform blood transfusion tests after working hours. Technologists of the Blood Transfusion Unit and Central Clinical Laboratory perform the test jointly, and column agglutination technology was introduced as the test method. A computer system setup exclusively for the testing was also introduced to perform computer cross-matching. Since transfusion error is likely to occur during emergency blood transfusion, a manual was established to prioritize safety. After introduction of the system, mistyping that may have been caused by inaccurate blood test results markedly decreased, confirming the usefulness of this system for prevention of mistyping. In addition, transfusion errors also decreased in wards and the improved system increased the safety of the entire medical care system. The frequency of mistyping was about 1% when physicians performed blood typing, showing the importance of clinical technologists for blood transfusion tests. PMID:12652691

  3. Preparation and results of a 24-hour orbital flight.

    PubMed

    Titov, G S

    1963-01-01

    The space age presents man with unprecedented opportunities for discovery and for cooperative endeavors to benefit all mankind. My flight of August 6-7, 1961 was conducted for the purpose of determining whether man can stay and work effectively and whether all systems of the spaceship can operate successfully during a period of 24 hours in space. The flight of Vostok II represents an experimental step in a logical sequence which included the first earth orbiting flight of USSR citizen Yuri A. Gagarin. Preparation for the flight included the study of theoretical and applied subjects, testing in various kinds of apparatus which provide acceleration, heat and isolation experience, brief airborne weightless flights and parachute landings, in addition to extensive training in a real spacecraft having simulators for normal and emergency contingencies of space flight. The actual flight was therefore carried out with a sense of confidence and familiarity and with continuous close radio contact with ground centers from whom my fellow cosmonauts served as spokesmen. Sequential boosters totaling 600 000 kg thrust placed the 4731 kg spaceship into a perfect orbit varying in altitude from 178-246 km in a plane 64 degrees 58' inclined to the equator. The spaceship made 17 orbits around the earth landing 25 hours, 18 minutes after take-off. The cabin had full atmospheric pressure and a comfortable habitability which could be extended for 10 days. I was able to maneuver the spaceship and perform many other control functions, make observations and take pictures of the earth and its cloud cover, eat meals and sleep all with good efficiency. I experienced mild symptoms suggestive of seasickness which were aggravated by head turning, ameliorated by sleep and entirely relieved by resumption of g-loading during descent. Altogether analyses of the physical and structural performance of the spaceship and the continuously monitored physiological responses of the pilot indicate that all

  4. Flexibility of working hours in the 24-hour society.

    PubMed

    Costa, G

    2006-01-01

    The 24-hour Society undergoes an ineluctable process towards a social organisation where time constraints are no more restricting human life. The borders between working and social times are no more fixed and rigidly determined, and the value of working time changes according to the different economic and social effects you may consider. Shift and night work, irregular and flexible working hours, together with new technologies, are the milestone of this epochal passage. What are the advantages and disadvantages for the individual, the companies, and the society? What is the cost/benefit ratio in terms of health and social well-being? Coping properly with this process means avoiding a passive acceptance of it with consequent maladjustments at both individual and social level, but adopting effective preventive and compensative strategies aimed at building up a more sustainable society. Flexible working times now appear to be one of the best ways to cope with the demands of the modern life, but there are different points of view about labour and temporal 'flexibility" between employers and employees. For the former it means a prompt adaptation to market demands and technological innovations; for the latter it is a way to improve working and social life, by decreasing work constraints and increasing control and autonomy. Although it can be easily speculated that individual-based 'flexibility" should improve health and well-being, and especially satisfaction, whereas company-based flexibility" might interfere negatively, the effective consequences on health and well-being have still to be analysed properly. PMID:17017360

  5. 49 CFR 40.31 - Who may collect urine specimens for DOT drug testing?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Who may collect urine specimens for DOT drug... urine specimens for DOT drug testing? (a) Collectors meeting the requirements of this subpart are the only persons authorized to collect urine specimens for DOT drug testing. (b) A collector must...

  6. Daily salt intake estimated by overnight urine collections indicates a high cardiovascular disease risk in Thailand.

    PubMed

    Yokokawa, Hirohide; Yuasa, Motoyuki; Nedsuwan, Supalert; Moolphate, Saiyud; Fukuda, Hiroshi; Kitajima, Tsutomu; Minematsu, Kazuo; Tanimura, Susumu; Marui, Eiji

    2016-01-01

    This cross-sectional study (February 2012 to March 2013) was conducted to estimate daily salt intake and basic characteristics among 793 community-dwelling participants at high risk of cardiovascular disease (Framingham risk score >15%), who had visited diabetes or hypertension clinics at health centres in the Muang district, Chiang Rai, Thailand. We performed descriptive analysis of baseline data and used an automated analyser to estimate the average of 24-hour salt intake estimated from 3 days overnight urine collection. Participants were divided into two groups based on median estimated daily salt intake. Mean age and proportion of males were 65.2 years and 37.6% in the higher salt intake group (>=10.0 g/day, n=362), and 67.5 years and 42.7% in the lower salt intake group (<10.0 g/day, n=431), respectively (p=0.01, p<0.01). The higher salt intake group comprised more patients with a family history of hypertension, antihypertensive drug use, less ideal body mass index (18.5-24.9), higher exercise frequency (>=2 times weekly) and lower awareness of high salt intake. Among higher salt intake participants, those with lower awareness of high salt intake were younger and more often had a family history of hypertension, relative to those with more awareness. Our data indicated that families often share lifestyles involving high salt intake, and discrepancies between actual salt intake and awareness of high salt intake may represent a need for salt reduction intervention aiming at family level. Awareness of actual salt intake should be improved for each family. PMID:26965760

  7. [Constant-infusion technique of inulin clearance without urine collection].

    PubMed

    Kamei, Koichi; Ito, Shuichi; Iijima, Kazumoto

    2011-01-01

    Inulin clearance is accepted as the gold standard for estimating the glomerular filtration rate (GFR). However, the method of this examination is troublesome and infants need difficult bladder catheterization. The existence of residual urine results in an inaccurate estimation of GFR and the proceduse requires a large amount of transfusion. In the plasma infusion method, inulin reaches an equilibrium in which the inulin urinary excretion rate is equal to the infusion rate, and urine collection is unnecessary. We estimated GFR in 21 children using both the plasma infusion method and renal infusion method. In the renal infusion method, the loading infusion of 1% inulin was administered over 30 minutes at the dose of 5 mL/kg body weight, followed by maintenance infusion at the constant speed (mL/hour) of 1.5 x estimated GFR (mL/min/1.73 m2) x body surface area (m2)/ 1.73. Three 30-minute urine collections were performed and the plasma inulin levels were measured to estimate GFR. In the plasma infusion method, maintenance infusion was conducted at the speed (mL/hour) of 0.6 x estimated GFR (mL/min/1.73 m2) x body surface area (m2)/1.73. The mean plasma inulin concentrations at 8, 9 and 10 hours were examined and GFR was calculated with the infusion rate. The GFRs for the renal infusion methods (Cin) and plasma infusion methods (e-Cin) were 91.90 +/- 39.61 and 95.33 +/- 38.08 mL/min/1.73 m2, respectively. The values for Cin and e-Cin showed good linear correlation (R2 = 0.81). The value of e-Cin/Cin was 1.069 +/- 0.172 and the mean e-Cin value was only 7% higher than that of Cin. We believe that GFR estimated by the constant infusion method shows a value approximating that estimated by the standard method. This technique is noninvasive for infants and the GFR of children who have vesicoureteral reflux or residual urine in the bladder can be estimated. The method does not need a large amount of transfusion and is suitable for children with heart failure. We believe that

  8. 24 hour blood pressure monitoring in healthy and hypertensive children.

    PubMed Central

    Reusz, G S; Hóbor, M; Tulassay, T; Sallay, P; Miltényi, M

    1994-01-01

    24 Hour ambulatory blood pressure monitoring (ABPM) was performed to provide data on the normal daily blood pressure of healthy schoolchildren and on patients with hypertension. The subjects studied were 123 healthy schoolchildren with a mean (SD) age of 12.5 (1.6) years (range 9.5-14.5 years), 24 children with borderline or mild hypertension, 17 with renal hypertension and normal renal function, 10 with chronic renal failure, and six with a renal allograft. In eight children with definite renal disease a second measurement was performed after treatment modification. The monitor used for ABPM was validated with a mercury column manometer. The mean (SD) of the signed differences of the blood pressure measured by the two methods was -0.19 (1.75) mmHg for the systolic and -0.21 (2.11) mmHg for the diastolic blood pressure (n = 60). Normal values for daytime and night time blood pressure were determined for those aged 10-14 years. The mean (SD) blood pressure of the 123 children was 109 (7)/66 (8) mmHg (systolic/diastolic) for the daytime and 96 (8)/52 (7) mmHg at night time. Of the 24 children with borderline or mild hypertension 14 had a raised blood pressure on ABPM. The circadian rhythm was disturbed in three children of this group. Even children with normal daytime blood pressure had significantly higher systolic blood pressure in the night when compared with the controls. The incidence of disturbed circadian rhythm was higher in the groups with renal hypertension (4/17 in the subgroup with normal renal function, 5/16 in the group with renal failure and/or transplantation). All children undergoing a second ABPM measurement had a lower average blood pressure after treatment adjustment. ABPM measurements were reproducible and accurate. The method provided new data on the physiological circadian variation of blood pressure in healthy children. It proved to be a helpful tool in the diagnosis of hypertension, particularly in the detection of cases of disturbance of the

  9. Strategy for NMR metabolomic analysis of urine in mouse models of obesity--from sample collection to interpretation of acquired data.

    PubMed

    Pelantová, Helena; Bugáňová, Martina; Anýž, Jiří; Železná, Blanka; Maletínská, Lenka; Novák, Daniel; Haluzík, Martin; Kuzma, Marek

    2015-11-10

    The mouse model of monosodium glutamate induced obesity was used to examine and consequently optimize the strategy for analysis of urine samples by NMR spectroscopy. A set of nineteen easily detectable metabolites typical in obesity-related studies was selected. The impact of urine collection protocol, choice of (1)H NMR pulse sequence, and finally the impact of the normalization method on the detected concentration of selected metabolites were investigated. We demonstrated the crucial effect of food intake and diurnal rhythms resulting in the choice of a 24-hour fasting collection protocol as the most convenient for tracking obesity-induced increased sensitivity to fasting. It was shown that the Carr-Purcell-Meiboom-Gill (CPMG) experiment is a better alternative to one-dimensional nuclear Overhauser enhancement spectroscopy (1D-NOESY) for NMR analysis of mouse urine due to its ability to filter undesirable signals of proteins naturally present in rodent urine. Normalization to total spectral area provided comparable outcomes as did normalization to creatinine or probabilistic quotient normalization in the CPMG-based model. The optimized approach was found to be beneficial mainly for low abundant metabolites rarely monitored due to their overlap by strong protein signals. PMID:26263053

  10. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 1 2012-10-01 2012-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements...

  11. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 1 2013-10-01 2013-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements...

  12. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 1 2014-10-01 2014-10-01 false Where does a urine collection for a DOT drug test... in DOT Urine Collections § 40.41 Where does a urine collection for a DOT drug test take place? (a) A urine collection for a DOT drug test must take place in a collection site meeting the requirements...

  13. Metabolic and renal changes in two athletes during a world 24 hour relay record performance.

    PubMed Central

    Irving, R A; Noakes, T D; van Zyl Smit, R

    1989-01-01

    Metabolic parameters and renal function were studied in two subjects before, during and after they established a world two-man 24 hour relay record. During the race, the athletes expended an estimated 37.747 and 42.880 kJ running at 54 and 61 per cent of maximum oxygen consumption (VO2max). Rectal temperatures reached maxima of 38.6 and 39.2 degrees C respectively during the race. Serum free fatty acid levels peaked at 2108 and 1875 mumol ml-1 after 24 hours; blood glucose levels varied from 4.3-6.5 and 4.9-8.5 mmol.l-1 respectively. Plasma insulin levels fell from 42.9 and 22.7 microU.ml-1 to 11.5 microU.ml-1. Plasma urea, creatinine, beta 2-microglobulin and C-reactive protein concentrations were elevated at the end of the race (to 9.0 and 8.0 mmol.l-1, 119 and 102 mumol.l-1, 3.508 and 3203 micrograms.l-1 and 2.7 and 3.9 mg per cent respectively). Plasma osmolality was altered from 293 and 304 to 302 and 280 mosmol.Kg-1 during the race but increased to 312 and 318 mosmol.Kg-1 the following day probably due to intercompartmental fluid shifts. Plasma creatinine concentration was increased by 38 and 26 per cent due to reduced urinary excretion. Urine flow rate increased 40 and 123 per cent respectively during the race, but creatinine clearance decreased by 38 and 40 per cent. Urine osmolality decreased by 38 and 65 per cent and osmolal clearance decreased by 15 and 16 per cent respectively. Urine sodium excretion was greatly reduced (85 and 90 per cent) on the post-race days (by 88 and 92 per cent on day 2). Both urine total protein and beta2-microglobulin excretion increased during the race (by 89 and 35 per cent and by 334 and 136 per cent respectively), but owing to the increased beta2-microglobulin production renal clearance was unaltered. The changes in renal function were temporary and some aspects of renal tubular function were enhanced during the post-race days. We conclude that, although C-reactive protein concentrations increased sooner and were higher

  14. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures...

  15. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures...

  16. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures...

  17. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures...

  18. 10 CFR 26.115 - Collecting a urine specimen under direct observation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Collecting a urine specimen under direct observation. 26.115 Section 26.115 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.115 Collecting a urine specimen under direct observation. (a) Procedures...

  19. After 24-hour scrub, another tower rollback for the Boeing Delta II rocket carrying Stardust

    NASA Technical Reports Server (NTRS)

    1999-01-01

    As tower rollback begins, the Boeing Delta II rocket carrying the Stardust spacecraft waits on Launch Pad 17-A, Cape Canaveral Air Station, for the second launch attempt at 4:04 p.m. EST. The original launch was scrubbed on Feb. 6 for 24 hours. Stardust is destined for a close encounter with the comet Wild 2 in January 2004. Using a silicon-based substance called aerogel, Stardust will capture comet particles flying off the nucleus of the comet. The spacecraft also will bring back samples of interstellar dust. These materials consist of ancient pre-solar interstellar grains and other remnants left over from the formation of the solar system. Scientists expect their analysis to provide important insights into the evolution of the sun and planets and possibly into the origin of life itself. The collected samples will return to Earth in a sample return capsule to be jettisoned as Stardust swings by Earth in January 2006.

  20. Variability of collagen crosslinks: impact of sample collection period

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Dillon, E. L.; DeKerlegand, D. E.; Davis-Street, J. E.

    2004-01-01

    Because of the variability of collagen crosslinks, their use as markers for bone resorption is often criticized. We hypothesized that the variability could be reduced by collecting urine for 24 hours (or longer) instead of using single voids, and by not normalizing to creatinine. Urine samples were collected from 22 healthy subjects during two or more 24-hour periods. Each 24-hour pool and each 2nd void of the day were analyzed for N-telopeptide (NTX), pyridinium (PYD), and deoxypyridinoline (DPD) crosslinks. Data were analyzed by using linear regression. For NTX, R2 for the two, 2nd-void samples (n = 38) was 0.55, whereas R2 for the two 24-hour pools was 0.51 or 0.52, expressed per day or per creatinine. For PYD and DPD, R2 for the 2nd-void samples was 0.26 and 0.18, R2 for the 24-hour pools expressed per day was 0.58 and 0.74, and R2 for the 24-hour pools expressed per creatinine was 0.65 and 0.76, respectively. Regression of the 2nd void and the corresponding 24-hour pool, expressed per day, yielded R2 = 0.19, 0.19, and 0.08, for NTX, PYD, and DPD, respectively (n = 76 each). For the 2nd-void sample and its corresponding 24-hour pool, expressed per creatinine, R2 = 0.24, 0.33, and 0.08, respectively. In a separate study, the coefficient of variation for NTX was reduced (P < 0.05) when data from more than one 24-hour collection were combined. Thus, the variability inherent in crosslink determinations can be reduced by collecting urine for longer periods. In research studies, the high variability of single-void collections, compounded by creatinine normalization, may alter or obscure findings.

  1. Tolvaptan Prolongs Blockage of the Vasopressin Type II Receptor Over 24 Hours in Responders With Stage D Heart Failure.

    PubMed

    Imamura, Teruhiko; Kinugawa, Koichiro; Komuro, Issei

    2016-01-01

    The urine aquaporin-2 (U-AQP2) level relative to the plasma arginine vasopressin (P-AVP) level is a novel predictor of the responsiveness to the vasopressin type 2 receptor (V2R) antagonist tolvaptan (TLV). However, little has been reported about the concentration-time profile of U-AQP2 after TLV treatment. We evaluated 24 patients with decompensated stage D heart failure (HF) who had received 3.75 mg/day of TLV on a de novo basis for > 7 days to treat congestion refractory to conventional diuretics. Seventeen patients were TLV-responders, whose 24-hour urine volume (UV) increased after TLV initiation; the other 7 patients were TLV-non-responders. The U-AQP2 of the TLV-responders, corrected for the urine creatinine concentration, decreased significantly at 4 hours after TLV administration without returning to the day-1 morning level on the morning of day-7. The TLV-non-responder U-AQP2 levels remained low even before the TLV treatment. On the morning of day-7, the TLV-responder U-AQP2/P-AVP ratio was comparable to that of the TLV-non-responders. Among 18 patients (11 responders and 7 non-responders), the day-7 TLV trough concentration was 64 ± 62 ng/mL and was negatively correlated with the estimated glomerular filtration rate (eGFR). TLV has antagonistic effects on the V2R over 24 hours in TLV-responders with advanced heart failure and chronic kidney disease, probably due to persistently elevated blood TLV concentration. The unresponsiveness to TLV in the TLV-non-responders is not attributable to malabsorption. PMID:26742881

  2. Time-Based Measurement of Personal Mite Allergen Bioaerosol Exposure over 24 Hour Periods.

    PubMed

    Tovey, Euan R; Liu-Brennan, Damien; Garden, Frances L; Oliver, Brian G; Perzanowski, Matthew S; Marks, Guy B

    2016-01-01

    Allergic diseases such as asthma and rhinitis are common in many countries. Globally the most common allergen associated with symptoms is produced by house dust mites. Although the bed has often been cited as the main site of exposure to mite allergens, surprisingly this has not yet been directly established by measurement due to a lack of suitable methods. Here we report on the development of novel methods to determine the pattern of personal exposure to mite allergen bioaerosols over 24-hour periods and applied this in a small field study using 10 normal adults. Air was sampled using a miniature time-based air-sampler of in-house design located close to the breathing zone of the participants, co-located with a miniature time-lapse camera. Airborne particles, drawn into the sampler at 2L/min via a narrow slot, were impacted onto the peripheral surface of a disk mounted on the hour-hand of either a 12 or 24 hour clock motor. The impaction surface was either an electret cloth, or an adhesive film; both novel for these purposes. Following a review of the time-lapse images, disks were post-hoc cut into subsamples corresponding to eight predetermined categories of indoor or outdoor location, extracted and analysed for mite allergen Der p 1 by an amplified ELISA. Allergen was detected in 57.2% of the total of 353 subsamples collected during 20 days of sampling. Exposure patterns varied over time. Higher concentrations of airborne mite allergen were typically measured in samples collected from domestic locations in the day and evening. Indoor domestic Der p 1 exposures accounted for 59.5% of total exposure, whereas total in-bed-asleep exposure, which varied 80 fold between individuals, accounted overall for 9.85% of total exposure, suggesting beds are not often the main site of exposure. This study establishes the feasibility of novel methods for determining the time-geography of personal exposure to many bioaerosols and identifies new areas for future technical

  3. Time-Based Measurement of Personal Mite Allergen Bioaerosol Exposure over 24 Hour Periods

    PubMed Central

    Tovey, Euan R.; Liu-Brennan, Damien; Garden, Frances L.; Oliver, Brian G.; Perzanowski, Matthew S.; Marks, Guy B.

    2016-01-01

    Allergic diseases such as asthma and rhinitis are common in many countries. Globally the most common allergen associated with symptoms is produced by house dust mites. Although the bed has often been cited as the main site of exposure to mite allergens, surprisingly this has not yet been directly established by measurement due to a lack of suitable methods. Here we report on the development of novel methods to determine the pattern of personal exposure to mite allergen bioaerosols over 24-hour periods and applied this in a small field study using 10 normal adults. Air was sampled using a miniature time-based air-sampler of in-house design located close to the breathing zone of the participants, co-located with a miniature time-lapse camera. Airborne particles, drawn into the sampler at 2L/min via a narrow slot, were impacted onto the peripheral surface of a disk mounted on the hour-hand of either a 12 or 24 hour clock motor. The impaction surface was either an electret cloth, or an adhesive film; both novel for these purposes. Following a review of the time-lapse images, disks were post-hoc cut into subsamples corresponding to eight predetermined categories of indoor or outdoor location, extracted and analysed for mite allergen Der p 1 by an amplified ELISA. Allergen was detected in 57.2% of the total of 353 subsamples collected during 20 days of sampling. Exposure patterns varied over time. Higher concentrations of airborne mite allergen were typically measured in samples collected from domestic locations in the day and evening. Indoor domestic Der p 1 exposures accounted for 59.5% of total exposure, whereas total in-bed-asleep exposure, which varied 80 fold between individuals, accounted overall for 9.85% of total exposure, suggesting beds are not often the main site of exposure. This study establishes the feasibility of novel methods for determining the time-geography of personal exposure to many bioaerosols and identifies new areas for future technical

  4. Assessment of 24-hours Aldosterone Administration on Protein Abundances in Fluorescence-Sorted Mouse Distal Renal Tubules by Mass Spectrometry

    PubMed Central

    Jensen, Thomas B; Pisitkun, Trairak; Hoffert, Jason D; Jensen, Uffe B; Fenton, Robert A; Praetorius, Helle A; Knepper, Mark A; Praetorius, Jeppe

    2013-01-01

    Background/Aims Aldosterone exerts multiple long-term effects in the distal renal tubules. The aim of this study was to establish a method for identifying proteins in these tubules that change in abundance by only 24-hours aldosterone administration. Methods Mice endogenously expressing green fluorescent protein (eGFP) in the connecting tubule and cortical collecting ducts were treated with a subcutaneous injection of 2.0 mg/kg aldosterone or vehicle (n=5), and sacrificed 24 hours later. Suspensions of single cells were obtained enzymatically, and eGFP positive cells were isolated by fluorescence activated cell sorting (FACS). Samples of 100 μg proteins were digested with trypsin and labeled with 8-plex iTRAQ reagents and processed for liquid chromatography tandem mass spectrometry (LC-MS/MS). Results FACS yielded 1.4 million cells per mouse. The LC-MS/MS spectra were matched to peptides by the SEQUEST search algorithm, which identified 3002 peptides corresponding to 506 unique proteins of which 20 significantly changed abundance 24-hours after aldosterone injection. Conclusion We find the method suitable and useful for studying hormonal effects on protein abundance in distal tubular segments. PMID:23428628

  5. 24-Hour ICH Score Is a Better Predictor of Outcome than Admission ICH Score

    PubMed Central

    Aysenne, Aimee M.; Albright, Karen C.; Mathias, Tiffany; Chang, Tiffany R.; Boehme, Amelia K.; Beasley, T. Mark; Martin-Schild, Sheryl

    2016-01-01

    Background The ICH score is a validated tool for predicting 30-day morbidity and mortality in patients with intracerebral hemorrhage. Aims and/or Hypothesis The aim of this study is to determine if the ICH score calculated 24 hours after admission is a better predictor of mortality than the ICH score calculated on admission. Methods Patients presenting to our center with ICH from 7/08-12/10 were retrospectively identified from our prospective stroke registry. ICH scores were calculated based on initial Glasgow coma scale (GCS) and emergent head computed tomography (CT) on initial presentation and were recalculated after 24 hours. Results A total of 91 patients out of 121 had complete data for admission and 24-hour ICH score. The ICH score changed in 38% from baseline to 24 hours. After adjusting for age, NIHSS on admission, and glucose, ICH score at 24 hours was a significant, independent predictor of mortality (OR = 2.71, 95% CI 1–19–6.20, and P = 0.018), but ICH score on admission was not (OR = 2.14, 95% CI 0.88-5.24, and P = 0.095). Conclusion Early determination of the ICH score may incorrectly estimate the severity and expected outcome after ICH. Calculations of the ICH score 24 hours after admission will better predict early outcomes.

  6. Dissociated 24-hour patterns of somatotropin and prolactin in fatal familial insomnia.

    PubMed

    Portaluppi, F; Cortelli, P; Avoni, P; Vergnani, L; Maltoni, P; Pavani, A; Sforza, E; Manfredini, R; Montagna, P; Roiter, I

    1995-06-01

    To assess the changes in the 24-hour profiles of serum somatotropin and prolactin levels during total disruption of the sleep/wake cycle sustained over several months, we studied 2 subjects affected by fatal familial insomnia, a rare disease characterized by selective thalamic degeneration that causes chronic sleep loss. Under standardized conditions and polysomnographic control, the patients underwent repeated 24-hour study sessions covering the entire clinical course of the disease. Hormones were assayed at 30-min intervals. Four healthy volunteers were used as controls. A sleep/wake cycle was always absent in fatal familial insomnia. Serum somatotropin and prolactin concentrations never exceeded the normal range of variation. The nocturnal elevation of somatotropin disappeared simultaneously with sleep loss, whereas a significant 24-hour component of variations in serum prolactin levels was present for months after total disruption of the sleep/wake cycle, with normally placed nocturnal acrophases. Complete obliteration of the 24-hour component was achieved for prolactin only in the advanced stages, through a progressive decrease in 24-hour amplitude of variation. Selective and progressive degeneration of the mediodorsal and anterior ventral nuclei of the thalamus causes an early obliteration of the 24-hour rhythm of somatotropin and a later disappearance of circadian prolactin rhythmicity.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Cross-Sectional Study of 24-Hour Urinary Electrolyte Excretion and Associated Health Outcomes in a Convenience Sample of Australian Primary Schoolchildren: The Salt and Other Nutrients in Children (SONIC) Study Protocol

    PubMed Central

    Baxter, Janet R; Campbell, Karen J; Riddell, Lynn J; Rigo, Manuela; Liem, Djin Gie; Keast, Russell S; He, Feng J; Nowson, Caryl A

    2015-01-01

    Background Dietary sodium and potassium are involved in the pathogenesis of cardiovascular disease. Data exploring the cardiovascular outcomes associated with these electrolytes within Australian children is sparse. Furthermore, an objective measure of sodium and potassium intake within this group is lacking. Objective The primary aim of the Salt and Other Nutrient Intakes in Children (“SONIC”) study was to measure sodium and potassium intakes in a sample of primary schoolchildren located in Victoria, Australia, using 24-hour urine collections. Secondary aims were to identify the dietary sources of sodium and potassium, examine the association between these electrolytes and cardiovascular risk factors, and assess children’s taste preferences and saltiness perception of manufactured foods. Methods A cross-sectional study was conducted in a convenience sample of schoolchildren attending primary schools in Victoria, Australia. Participants completed one 24-hour urine collection, which was analyzed for sodium, potassium, and creatinine. Completeness of collections was assessed using collection time, total volume, and urinary creatinine. One 24-hour dietary recall was completed to assess dietary intake. Other data collected included blood pressure, body weight, height, waist and hip circumference. Children were also presented with high and low sodium variants of food products and asked to discriminate salt level and choose their preferred variant. Parents provided demographic information and information on use of discretionary salt. Descriptive statistics will be used to describe sodium and potassium intakes. Linear and logistic regression models with clustered robust standard errors will be used to assess the association between electrolyte intake and health outcomes (blood pressure and body mass index/BMI z-score and waist circumference) and to assess differences in taste preference and discrimination between high and low sodium foods, and correlations between

  8. 24-hour central blood pressure and intermediate cardiovascular phenotypes in untreated subjects

    PubMed Central

    Bednarek, Agnieszka; Jankowski, Piotr; Olszanecka, Agnieszka; Windak, Adam; Kawecka-Jaszcz, Kalina; Czarnecka, Danuta

    2014-01-01

    Background: Recently, 24-hour monitoring of central systolic blood pressure (SBP) has become available. However, the relation between end-organ damage and the 24-hour central SBP profile and variability has not so far been analyzed. Therefore, the aim of this cross-sectional study was to evaluate the relation between 24-hour central SBP, 24-hour central SBP profile as well as central SBP short-term variability and parameters of cardiac and vascular intermediate phenotypes. Methods: The study group consisted of 50 patients with newly diagnosed, untreated hypertension (age 40.4 ± 11.5 years, 35 men) and 50 normotensive subjects (age 38.3 ± 12.0 years, 35 men). Applanation tonometry of the radial artery and the “n-point forward moving average” method were used to determine 24-hour central SBP. Each study participant underwent echocardiography and carotid ultrasonography. Results: 24-hour, daytime, and nighttime central SBP was related to left ventricle end-diastole diameter (p < 0.05), left ventricular mass index (p < 0.001), relative wall thickness (p < 0.05), E/E’ ratio (p < 0.01), and left atrium volume (p < 0.01). The nocturnal central SBP fall was not related to any of the mentioned parameters, whereas parameters of short-term variability were related to IMT in hypertensives only (p < 0.05). Conclusions: The present study showed that 24-hour central SBP is related to intermediate cardiac phenotypes as assessed by echocardiography whereas short-term central SBP variability is mainly related to vascular phenotype as determined by IMT. PMID:25628959

  9. Metabolism and Excretion Rates of Parent and Hydroxy-PAHs in Urine Collected after Consumption of Traditionally Smoked Salmon for Native American Volunteers

    PubMed Central

    Motorykin, Oleksii; Santiago-Delgado, Lisandra; Rohlman, Diana; Schrlau, Jill E.; Harper, Barbara; Harris, Stuart; Harding, Anna; Kile, Molly L.; Massey Simonich, Staci L.

    2015-01-01

    Few studies have been published on the excretion rates of parent polycyclic aromatic hydrocarbons (PAHs) and hydroxy-polycyclic aromatic hydrocarbons (OH-PAHs) following oral exposure. This study investigated metabolism and excretion rates of 4 parent PAHs and 10 OH-PAHs after the consumption of smoked salmon. Nine members of the Confederated Tribes of the Umatilla Indian Reservation consumed 50 g of traditionally smoked salmon with breakfast and five urine samples were collected during the following 24 hours. The concentrations of OH-PAHs increased from 43.9 μg/g creatinine for 2-OH-Nap to 349 ng/g creatinine for 1-OH-Pyr, 3 to 6 hr post-consumption. Despite volunteers following a restricted diet, there appeared to be a secondary source of naphthalene and fluorene, which led to excretion efficiencies greater than 100%. For the parent PAHs that were detected in urine, the excretion efficiencies ranged from 13% for phenanthrene (and its metabolite) to 240% for naphthalene (and its metabolites). The half-lives for PAHs ranged from 1.4 hr for retene to 3.3 hr for pyrene. The half-lives for OH-PAHs were higher and ranged from 1.7 hr for 9-OH-fluorene to 7.0 hr for 3-OH-fluorene. The concentrations of most parent PAHs, and their metabolites, returned to the background levels 24 hr post-consumption. PMID:25659315

  10. Technique for the collection of clear urine from the Nile crocodile (Crocodylus niloticus).

    PubMed

    Myburgh, Jan G; Huchzermeyer, Fritz W; Soley, John T; Booyse, Dirk G; Groenewald, Herman B; Bekker, Lizette C; Iguchi, Taisen; Guillette, Louis J

    2012-07-03

    Urine samples can be a very useful diagnostic tool for the evaluation of animal health. In this article, a simple technique to collect urine from the Nile crocodile (Crocodylus niloticus) was described, based on a similar unpublished technique developed for the American alligator (Alligator mississippiensis) using a canine urinary catheter. With this technique, it was possible to collect relatively clean urine samples from Nile crocodiles of different sizes using canine urinary catheters or small diameter stomach tubes. Based on the gross anatomical features of the cloaca of the Nile crocodile, it was confirmed that urine accumulates in a chamber consisting of the urodeum and coprodeum. Faecal material is stored temporarily in the very short rectum, which is separated from the urinary chamber by the rectocoprodeal sphincter.

  11. Microtensile bond strength of resin-resin interfaces after 24-hour and 2-month soaking.

    PubMed

    Leavitt, Curry; Boberick, Kenneth G; Winkler, Sheldon

    2007-01-01

    Evaluate the bond strengths of denture base-repair materials to minimize recurrent failure rate. Use microtensile bond strength (muTBS) testing to evaluate the interfacial bonding strength of 6 commercial denture repair materials after 24-hour and 12-month soaking. Blocks of poly(methyl metacrylate) (PMMA) and Triad were fabricated, fractured, and repaired. Twenty bars (1 x 1 x 30 mm) per group were sectioned from each block parallel to the long axis and approximately 90 degrees to the resin-resin repair interface and stored before muTBS testing in a servo-hydraulic tensile-testing machine. Intact PMMA and Triad bars that had been soaked for 24 hours and 12 months were tested for reference. The 24-hour repair strengths for PMMA ranged from 52% to 84% of original strength. Soaking for 12 months resulted in a 20% decrease in strength for the PMMA control. The 12-month repair strengths for PMMA ranged from 43% to 74% of the 12-month soaked material strength. Triad repair tested 35% of original strength after soaking for 24 hours. Permabond (cyanoacrylate) to PMMA tested 47% of original strength after 24 hours of soaking and 26% of the 12-month soaked material strength. Permabond to Triad tested 30% of original strength after 24 hours of soaking. Permabond and Triad showed a 100% adhesive mode of failure. All other materials tested exhibited either an adhesive mode of failure at the denture base-repair-material interface or a complex cohesive failure within the repair-material interface. The muTBS approach can be used to analyze the resin-resin interface of repaired acrylics. The relatively small standard deviations make the muTBS approach attractive. In this study, muTBS was used to evaluate the repair strength of 6 denture repair materials enabling clinicians to make clinical judgments regarding the strongest repair bond available. PMID:17987865

  12. Developing a Method to Test the Validity of 24 Hour Time Use Diaries Using Wearable Cameras: A Feasibility Pilot

    PubMed Central

    Kelly, Paul; Thomas, Emma; Doherty, Aiden; Harms, Teresa; Burke, Órlaith; Gershuny, Jonathan; Foster, Charlie

    2015-01-01

    Self-report time use diaries collect a continuous sequenced record of daily activities but the validity of the data they produce is uncertain. This study tests the feasibility of using wearable cameras to generate, through image prompted interview, reconstructed 'near-objective' data to assess their validity. 16 volunteers completed the Harmonised European Time Use Survey (HETUS) diary and used an Autographer wearable camera (recording images at approximately 15 second intervals) for the waking hours of the same 24-hour period. Participants then completed an interview in which visual images were used as prompts to reconstruct a record of activities for comparison with the diary record. 14 participants complied with the full collection protocol. We compared time use and number of discrete activities from the diary and camera records (using 10 classifications of activity). In terms of aggregate totals of daily time use we found no significant difference between the diary and camera data. In terms of number of discrete activities, participants reported a mean of 19.2 activities per day in the diaries, while image prompted interviews revealed 41.1 activities per day. The visualisations of the individual activity sequences reveal some potentially important differences between the two record types, which will be explored at the next project stage. This study demonstrates the feasibility of using wearable cameras to reconstruct time use through image prompted interview in order to test the concurrent validity of 24-hour activity time-use budgets. In future we need a suitably powered study to assess the validity and reliability of 24-hour time use diaries. PMID:26633807

  13. Urine specimen collection following consensual intercourse - A forensic evidence collection method for Y-DNA and spermatozoa.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Karhunen, Pekka J

    2016-01-01

    The purpose of the prospective research was to evaluate the benefit of urine specimen as a collection technique for biological forensic evidence in adult volunteers following consensual intercourse. For detecting Y-chromosomal material Buccal Swab Spin Protocol(®) was used in DNA extraction and purification and samples were analysed with Quantifiler Y Human Male DNA Quantification Kit(®). The time frame for positive Y-DNA was evaluated. Immediate microscopy for detection of spermatozoa was performed. Y-DNA was detected in 173/205 (84.4%) urine samples. Of the 86 first post-coital void urine samples available, Y-DNA was detected in 83 (96.5%) specimens. Of the 119 urine samples from volunteers with post-coital activities Y-DNA was still measurable in 70 (58.8%) urine specimens. The male DNA amount was below 0.023 ng/μl in 28/153 (18.3%) urine samples. Of the 22 urine samples obtained after 24 post-coital hours, 9 (40.9%) were still Y-DNA positive. No associations were found between coital durance, coital frequency during the past two weeks prior to the study intercourse, post-coital activities, and the urine sample Y-DNA positivity. Of the 111 urine samples where the immediate microscopy was performed, in 66 (59.5%) samples spermatozoa were verified and one sample even contained motile spermatozoa. Microscopy detected 66 (67.3%) and failed to detect spermatozoa in 32 (32.7%) of Y-DNA positive samples. In addition to conventional invasive swab techniques, urine samples seem to be an effective biological trace collection method for Y-DNA and spermatozoa within 24 h following penile-vaginal penetration. Furthermore, it may be considered as a non-invasive collection method in suspected acute child sexual abuse cases to diminish time delay in forensic evidence collection and to improve patients' positive attitudes towards evidence collection.

  14. Usability of a smartphone food picture app for assisting 24-hour dietary recall: a pilot study

    PubMed Central

    Pope, Benjamin T.; Bilgiç, Pelin; Orr, Barron J.; Suzuki, Asuka; Kim, Angela Sarah; Merchant, Nirav C.; Roe, Denise J.

    2015-01-01

    BACKGROUND/OBJECTIVES The Recaller app was developed to help individuals record their food intakes. This pilot study evaluated the usability of this new food picture application (app), which operates on a smartphone with an embedded camera and Internet capability. SUBJECTS/METHODS Adults aged 19 to 28 years (23 males and 22 females) were assigned to use the Recaller app on six designated, nonconsecutive days in order to capture an image of each meal and snack before and after eating. The images were automatically time-stamped and uploaded by the app to the Recaller website. A trained nutritionist administered a 24-hour dietary recall interview 1 day after food images were taken. Participants' opinions of the Recaller app and its usability were determined by a follow-up survey. As an evaluation indicator of usability, the number of images taken was analyzed and multivariate Poisson regression used to model the factors determining the number of images sent. RESULTS A total of 3,315 food images were uploaded throughout the study period. The median number of images taken per day was nine for males and 13 for females. The survey showed that the Recaller app was easy to use, and 50% of the participants would consider using the app daily. Predictors of a higher number of images were as follows: greater interval (hours) between the first and last food images sent, weekend, and female. CONCLUSIONS The results of this pilot study provide valuable information for understanding the usability of the Recaller smartphone food picture app as well as other similarly designed apps. This study provides a model for assisting nutrition educators in their collection of food intake information by using tools available on smartphones. This innovative approach has the potential to improve recall of foods eaten and monitoring of dietary intake in nutritional studies. PMID:25861429

  15. Weekend versus weekday urine collections in assessment of stone-formers.

    PubMed Central

    Norman, R W

    1996-01-01

    Twenty-four-hour urine collections are an important part of the metabolic evaluation of stone-formers, but are difficult for patients at work. At weekends the results might be different. Forty-five stone-formers who worked at day jobs from Monday to Friday collected urine for 24 h on a normal working day and also on a Saturday or Sunday and the differences were evaluated. Average 24 h urine volume was higher on weekdays than at weekends. Calcium, oxalate, and uric acid excretion did not differ. These results imply an increased risk of crystalluria at the weekend. Therefore weekend collections are most likely to show abnormalities and should be acceptable to clinicians. PMID:8976890

  16. Positive reinforcement methods to train chimpanzees to cooperate with urine collection.

    PubMed

    Bloomsmith, Mollie; Neu, Kim; Franklin, Andrea; Griffis, Caroline; McMillan, Jennifer

    2015-01-01

    Positive reinforcement training can be used in many ways to enhance the welfare of captive primates. Training for biologic sample collection is one application of positive reinforcement training. In this study, 35 adult female chimpanzees were trained to cooperate with the collection of urine samples needed to facilitate a research study. A median of 35 training sessions was required for the subjects to reach reliable performance (4 of 5 sequential attempts successful) of the urine collection behavior. Adult age had no effect on the speed of learning as indicated by a rank order correlation. Individual differences in the rate of learning were pronounced but did not vary with the age of the chimpanzees. Approximately 2 y after the initial training, and with continual sample collection taking place twice weekly, we assessed the reliability of their performance and found that the chimpanzees cooperated 100% of the time and that collection of a urine sample required about 5 min. Positive reinforcement training can markedly reduce staff time, particularly for studies such as this that require frequent biologic sample collection over long durations. Similar approaches could be used to train other laboratory primates to cooperate with urine collection procedures. Animal training programs that emphasize positive reinforcement training are an important refinement in the care of laboratory primates.

  17. Positive Reinforcement Methods to Train Chimpanzees to Cooperate with Urine Collection

    PubMed Central

    Bloomsmith, Mollie; Neu, Kim; Franklin, Andrea; Griffis, Caroline; McMillan, Jennifer

    2015-01-01

    Positive reinforcement training can be used in many ways to enhance the welfare of captive primates. Training for biologic sample collection is one application of positive reinforcement training. In this study, 35 adult female chimpanzees were trained to cooperate with the collection of urine samples needed to facilitate a research study. A median of 35 training sessions was required for the subjects to reach reliable performance (4 of 5 sequential attempts successful) of the urine collection behavior. Adult age had no effect on the speed of learning as indicated by a rank order correlation. Individual differences in the rate of learning were pronounced but did not vary with the age of the chimpanzees. Approximately 2 y after the initial training, and with continual sample collection taking place twice weekly, we assessed the reliability of their performance and found that the chimpanzees cooperated 100% of the time and that collection of a urine sample required about 5 min. Positive reinforcement training can markedly reduce staff time, particularly for studies such as this that require frequent biologic sample collection over long durations. Similar approaches could be used to train other laboratory primates to cooperate with urine collection procedures. Animal training programs that emphasize positive reinforcement training are an important refinement in the care of laboratory primates. PMID:25651093

  18. Mood-Dependent Cognitive Change in a Man with Bipolar Disorder Who Cycles Every 24 Hours

    ERIC Educational Resources Information Center

    Lam, Dominic; Mansell, Warren

    2008-01-01

    A case study of a bipolar patient whose mood changes every 24 hours is described to illustrate the changes in cognitive processing and content during different phases of bipolar disorder. The participant completed a battery of questionnaires and tasks on 4 separate occasions: twice when depressed and twice when manic. Depression tended to be…

  19. Leg skinfold thicknesses and race performance in male 24-hour ultra-marathoners.

    PubMed

    Knechtle, Beat; Knechtle, Patrizia; Rüst, Christoph Alexander; Rosemann, Thomas

    2011-04-01

    The association of skinfold thicknesses with race performance has been investigated in runners competing over distances of ≤50 km. This study investigated a potential relation between skinfold thicknesses and race performance in male ultra-marathoners completing >50 km in 24 hours. Variables of anthropometry, training, and previous performance were related to race performance in 63 male ultra-marathoners aged 46.9 (standard deviation [SD] 10.3) years, standing 1.78 (SD 0.07) m in height, and weighing 73.3 (SD 7.6) kg. The runners clocked 146.1 (SD 43.1) km during the 24 hours. In the bivariate analysis, several variables were associated with race performance: body mass (r = -0.25); skinfold thickness at axilla (r = -0.37), subscapula (r = -0.28), abdomen (r = -0.31), and suprailiaca (r = -0.30); the sum of skinfold thicknesses (r = -0.32); percentage body fat (r = -0.32); weekly kilometers run (r = 0.31); personal best time in a marathon (r = -0.58); personal best time in a 100-km ultra-run (r = -0.31); and personal best performance in a 24-hour run (r = 0.46). In the multivariate analysis, no anthropometric or training variable was related to race performance. In conclusion, in contrast to runners up to distances of 50 km, skinfold thicknesses of the lower limbs were not related to race performance in 24-hour ultra-marathoners.

  20. The Three-Continent, 24-Hour Help Desk: An Academic First?

    ERIC Educational Resources Information Center

    Sykes, Jean

    2002-01-01

    Describes Follow the Sun, a computer help-desk service that takes advantage of time differences around the world to permit four universities (University of Colorado Boulder, Australia's Macquarie and Newcastle universities, and the London School of Economics) to share services and provide 24-hour support to users. (EV)

  1. Assessing dietary intake in childhood cancer survivors: Food frequency questionnaire versus 24-hour diet recalls

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet r...

  2. Oropharyngeal 24-Hour pH Monitoring in Children With Airway-Related Problems

    PubMed Central

    Mesallam, Tamer A.

    2016-01-01

    Objectives Diagnosis and clinical presentation of pediatric laryngopharyngeal reflux (LPR) is still controversial. The aims of this work were to study the possibility of performing 24-hour oropharyngeal pH monitoring for children in the outpatient clinic setup and to explore the results of this test in correlation to airway-related problems. Methods In this descriptive qualitative study, 26 children suffering from airway-related problems were included. Oropharyngeal 24-hour pH monitoring was performed for all subjects in the outpatient clinic setting. The distribution of airway diagnoses among the study group was studied versus the results of the pH monitoring. Results There were 16 males and 10 females participated in the study with a mean age of 6.88 (SD, ±5.77) years. Thirty-five percent of the patients were under the age of 3 years (range, 11 months to 3 years). Eight-five percent of the patients tolerated the pH probe insertion and completed 24-hour of pH recording. Laryngomalacia and subglottic stenosis (SGS) were more frequently reported in the positive LPR patients (77%). Conclusion Oropharyngeal 24-hour pH monitoring can be conducted for children in the outpatient setup even in young age children below 3 years old. Among the positive LPR group, SGS and laryngomalacia were the most commonly reported airway findings. PMID:27090271

  3. Pilot Study: Colostomy and Urine Collection Protocol for Investigating Potential Inciting Causes of Hen Diuresis Syndrome.

    PubMed

    Jones, Kelli; Turner, Bradley; Brandão, João; Hubbard, Sue Ann; Magee, Danny; Baughman, Brittany; Wills, Robert; Tully, Thomas

    2015-06-01

    Hen diuresis syndrome has emerged over the past 5 yr as a significant cause of mortality in the U.S. broiler breeder industry. The condition affects hens in production and is characterized by transient muscle weakness in the vent region, transient diuresis, and often urate deposits on the skin below the vent. Affected hens are often seen straining to lay an egg, which suggests oviduct contraction is also impaired. Related hen mortality, often reaching 1% or more a week, is believed to be primarily the result of male aggression of the vent region (Turner et al., "Investigating Causes of Excessive Urate Production in Broiler Breeder Hens Associated with Peritonitis and Cannibalism Mortality," Oral Presentation at The American Association of Avian Pathologists Annual Meeting, p. 139, 2010). The exact association between the cause of mortality and this syndrome is unknown, but it may be the consequence of transient partial to full oviduct prolapse, which predisposes or stimulates cannibalism and aggression. Based on unpublished work done prior to this study (Turner et al., ibid.), the evidence suggests the underlying problem is metabolic. We feel that urine collection and analysis is an essential component to understanding this condition. This study serves as a pilot study for future investigations that attempt to identify the nature and cause of the metabolic disturbance through paired urine and serum collection and analysis. For the purpose of this study, a small sample of 10 affected and 10 unaffected birds was used for sample collection. In order to collect pure urine, the birds were surgically colostomized. Colostomy did prove to be a useful means of collecting urine free of feces, and for the purposes of our study it yielded adequate urine samples for analysis. There were statistically relevant urine values observed. Affected birds had a higher presence of blood in the urine, a lower uric acid excretion rate (mg/hr), higher concentration (mEq/L) of urine Na+, and

  4. Comparison of various urine collection intervals for caffeine and dextromethorphan phenotyping in children.

    PubMed

    Kennedy, Mary Jayne; Abdel-Rahman, Susan M; Kashuba, Angela D M; Leeder, J Steven

    2004-07-01

    Caffeine and dextromethorphan have been used successfully both alone and in combination to assess phenotype and enzyme activity in children of various ages. Previous pediatric phenotyping studies with these agents have used varying durations of urine collection. However, the minimum duration required for accurate phenotypic assessment with these compounds in children remains unknown. We calculated the cumulative metabolite recoveries and molar ratios in urine collected from children for 2, 4, 6, and 8 hours after caffeine and dextromethorphan administration to determine when respective urinary molar ratios stabilize and thus likely accurately reflect enzyme activity. Subjects (n = 24, ages 3-8 years) were given 4 oz of Coca-Cola(R) ( approximately 11.5 mg caffeine) and a single oral dose of dextromethorphan (0.5 mg/kg). Urine was collected at discrete intervals (0-2, 2-4, 4-6, and 6-8 h) during an 8-hour period, and the cumulative metabolite recoveries and urinary molar ratios were calculated. CYP2D6 genotyping was also performed in 21 of 24 subjects. In CYP2D6 extensive metabolizers, the extent of recovery for relevant metabolites was equivalent by 4 hours and represented 45% to 60% of the total amount recovered in the 8-hour period. The 2-hour CYP1A2 ratio was significantly different from those of longer collection intervals. Metabolite ratios for all other enzymes (i.e., NAT-2, XO, and CYP2D6) were independent of the duration of urine collection. These data suggest that a 4-hour urine collection is adequate for the concurrent assessment of hepatic CYP1A2, NAT-2, XO, and CYP2D6 activity in children ages 3 to 8 years who are CYP2D6 extensive metabolizers, using standard caffeine and dextromethorphan phenotyping methods. Longer collection periods may be required, however, in younger children or CYP2D6 poor metabolizers. PMID:15199075

  5. Comparison of Interviewer-Administered and Automated Self-Administered 24-Hour Dietary Recalls in 3 Diverse Integrated Health Systems.

    PubMed

    Thompson, Frances E; Dixit-Joshi, Sujata; Potischman, Nancy; Dodd, Kevin W; Kirkpatrick, Sharon I; Kushi, Lawrence H; Alexander, Gwen L; Coleman, Laura A; Zimmerman, Thea P; Sundaram, Maria E; Clancy, Heather A; Groesbeck, Michelle; Douglass, Deirdre; George, Stephanie M; Schap, TusaRebecca E; Subar, Amy F

    2015-06-15

    Twenty-four-hour dietary recalls provide high-quality intake data but have been prohibitively expensive for large epidemiologic studies. This study's goal was to assess whether the web-based Automated Self-Administered 24-Hour Recall (ASA24) performs similarly enough to the standard interviewer-administered, Automated Multiple-Pass Method (AMPM) 24-hour dietary recall to be considered a viable alternative. In 2010-2011, 1,081 adults from 3 integrated health systems in Detroit, Michigan; Marshfield, Wisconsin; and Kaiser-Permanente Northern California participated in a field trial. A quota design ensured a diverse sample by sex, age, and race/ethnicity. Each participant was asked to complete 2 recalls and was randomly assigned to 1 of 4 protocols differing by type of recall and administration order. For energy, the mean intakes were 2,425 versus 2,374 kcal for men and 1,876 versus 1,906 kcal for women by AMPM and ASA24, respectively. Of 20 nutrients/food groups analyzed and controlling for false discovery rate, 87% were judged equivalent at the 20% bound. ASA24 was preferred over AMPM by 70% of the respondents. Attrition was lower in the ASA24/AMPM study group than in the AMPM/ASA24 group, and it was lower in the ASA24/ASA24 group than in the AMPM/AMPM group. ASA24 offers the potential to collect high-quality dietary intake information at low cost with less attrition.

  6. Predictors of poor blood pressure control assessed by 24 hour monitoring in patients with type B acute aortic dissection

    PubMed Central

    Delsart, Pascal; Midulla, Marco; Sobocinski, Jonathan; Achere, Charles; Haulon, Stephan; Claisse, Gonzague; Mounier-Vehier, Claire

    2012-01-01

    The chronic management of post-acute aortic dissection (AD) of the descending aorta (Type B) is based on optimal control of blood pressure (BP), with a target BP < 135/80 mmHg. The aim of our study was to determine and verify effective blood pressure control with an objective measurement method and to identify predicting factors. Methods We collected data from 26 patients hospitalized in the acute phase of a Type B AD between 2006 and 2009. Two groups were defined according to 24 hour BP monitoring results at follow-up. Group 1 consisted of patients with a controlled BP (<130/80 mmHg), and Group 2 consisted of patients with an uncontrolled BP. Results Thirty four percent of patients showed an uncontrolled BP at checkup. Vascular history before AD (P = 0.06), high baseline BP trend (P = 0.01 for systolic and P = 0.08 for diastolic), and greater diameter of the descending aorta (P = 0.02) were associated with poor BP control. Conclusion Prognosis after AD is associated with BP control. Therefore, 24 hour BP monitoring can be made. PMID:22272072

  7. Seasonal changes of 24-hour intraocular pressure rhythm in healthy Shanghai population

    PubMed Central

    Cheng, Jingyi; Xiao, Ming; Xu, Huan; Fang, Shaobin; Chen, Xu; Kong, Xiangmei; Sun, Xinghuai

    2016-01-01

    Abstract The aim of the present study was to investigate and compare the 24-hour intraocular pressure (IOP) rhythms in winter and summer in the healthy population of Shanghai, China. This is a cross-sectional study in which 24-hour IOP measurements were taken for all eligible healthy volunteers in winter and summer, respectively, and the temperature, hours of sunlight (sunlight time), and circulatory parameters, including heart rate, systolic blood pressure, and diastolic blood pressure, were also recorded. The 24-hour IOP curves and IOP parameters (mean, peak, trough, and fluctuation of IOP together with the diurnal-to-nocturnal IOP change) in winter and summer were obtained and compared. The magnitude of IOP changes from summer to winter was also calculated. A total of 29 participants (58 eyes), 14 (48.28%) male and 15 (51.72%) female, aged 43.66 ± 12.20 (19–61) years, were considered eligible for this study. Generally, IOP decreased progressively before noon, increased notably in the nocturnal period, and peaked at 12:00 am in winter and at 2:00 am in summer. The pattern of 24-hour IOP in winter and summer was significantly different (P = 0.002). The average IOPs from 4:00 pm to 8:00 am, except for 6:00 am, were significantly higher in winter (P < 0.05). However, no significant differences were shown after adjusting for temperature and/or sunlight time. From summer to winter, the extent of IOP increase was mostly around 0 to 3 mm Hg, and the IOPs increased more significantly in the nocturnal period than in the diurnal period (P = 0.05). The 24-hour IOP rhythms were different in winter and summer, with higher IOP level in winter. Temperature and sunlight time, which are independent of heart rate and blood pressure, affected the 24-hour IOP rhythms in healthy people in Shanghai, China. Further investigations are expected for the rhythm of some endogenous substance secretion and the inner mechanism of regulation of IOP. PMID:27495076

  8. 49 CFR 40.45 - What form is used to document a DOT urine collection?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... number. (3) As an employer, in Step 1-D of the CCF you may preprint the box for the DOT Agency under... 49 Transportation 1 2010-10-01 2010-10-01 false What form is used to document a DOT urine... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Collection Sites, Forms, Equipment and Supplies...

  9. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  10. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  11. [Identification of paroxysmal, transient arrhythmias: Intermittent registration more efficient than the 24-hour Holter monitoring].

    PubMed

    Hendrikx, Tijn; Rosenqvist, Mårten; Sandström, Herbert; Persson, Mats; Hörnsten, Rolf

    2015-01-06

    Many patients suffer from palpitations or dizziness/presyncope. These patients are often referred for Holter ECG (24 hour), although the sensitivity for detecting arrhythmias is low. A new method, short intermittent regular and symptomatic ECG registrations at home, might be a convenient and more sensitive alternative also suitable for primary health care. In this case report we present a patient who had contacted health care several times during a seven year period for paroxysmal palpitations. Routine examination with 24 hour Holter ECG and event recorder did not result in a diagnosis. Using intermittent handheld ECG registration at home, a paroxysmal supraventricular arrhythmia was diagnosed. Further investigation revealed that the patient had a concealed Wolff-Parkinson-White (WPW) syndrome.

  12. Demonstration that thiazole-orange-positive platelets in the dog are less than 24 hours old.

    PubMed

    Dale, G L; Friese, P; Hynes, L A; Burstein, S A

    1995-04-01

    Approximately 6% of dog platelets are positive for staining with thiazole orange, a dye frequently used to stain ribonucleic acid. In this report, thiazole-orange positivity is shown to mark platelets that are less than 24 hours old. Dog platelets were derivatized in vivo with N-hydroxysuccinimido biotin such that greater than 95% of all platelets were biotinylated. Newly synthesized, nonbiotinylated platelets were then monitored by flow cytometry for their ability to bind thiazole orange. After biotinylation, the percentage of biotin-negative, thiazole-orange-positive platelets increased gradually from 0.72% at 30 minutes to 5.44% at 24 hours. These data indicate that thiazole-orange staining does label newly synthesized platelets.

  13. [Contraceptive effect of spermicide on cervical mucus in vivo after 24 hours (authors transl)].

    PubMed

    Batallan, L; Brissi, J; Commerot, J

    1980-10-01

    Efficacy of Alpagelle, a vaginal contraceptive jelly containing benzalkonium chlorohydrate, was tested on 34 women who had been using it for some. The testing was conducted using fresh human spermatozoa, and measuring the penetration into the cervical mucus 24 hours after instillation of 2 ml. of Alpagelle. Maximum penetration of spermatozoa before immobilization and death was 2/10 mm., while it is 2mm. a minute under normal conditions. Alpagelle has no contraindications, and only 1 application every 24 hours will provide contraceptive protection; such method could be ideal for women presenting temporary or permanent contraindications to the IUD, or to the pill, or to those who wish to opt for a method free of side effects. PMID:12262152

  14. Circadian Polymorphisms in Night Owls, in Bipolars, and in Non-24-Hour Sleep Cycles

    PubMed Central

    Klimecki, Walter T.; Nievergelt, Caroline M.; Rex, Katharine M.; Murray, Sarah S.; Shekhtman, Tatyana; Tranah, Gregory J.; Loving, Richard T.; Lee, Heon-Jeong; Rhee, Min Kyu; Shadan, Farhad F.; Poceta, J. Steven; Jamil, Shazia M.; Kline, Lawrence E.; Kelsoe, John R.

    2014-01-01

    People called night owls habitually have late bedtimes and late times of arising, sometimes suffering a heritable circadian disturbance called delayed sleep phase syndrome (DSPS). Those with DSPS, those with more severe progressively-late non-24-hour sleep-wake cycles, and those with bipolar disorder may share genetic tendencies for slowed or delayed circadian cycles. We searched for polymorphisms associated with DSPS in a case-control study of DSPS research participants and a separate study of Sleep Center patients undergoing polysomnography. In 45 participants, we resequenced portions of 15 circadian genes to identify unknown polymorphisms that might be associated with DSPS, non-24-hour rhythms, or bipolar comorbidities. We then genotyped single nucleotide polymorphisms (SNPs) in both larger samples, using Illumina Golden Gate assays. Associations of SNPs with the DSPS phenotype and with the morningness-eveningness parametric phenotype were computed for both samples, then combined for meta-analyses. Delayed sleep and "eveningness" were inversely associated with loci in circadian genes NFIL3 (rs2482705) and RORC (rs3828057). A group of haplotypes overlapping BHLHE40 was associated with non-24-hour sleep-wake cycles, and less robustly, with delayed sleep and bipolar disorder (e.g., rs34883305, rs34870629, rs74439275, and rs3750275 were associated with n=37, p=4.58E-09, Bonferroni p=2.95E-06). Bright light and melatonin can palliate circadian disorders, and genetics may clarify the underlying circadian photoperiodic mechanisms. After further replication and identification of the causal polymorphisms, these findings may point to future treatments for DSPS, non-24-hour rhythms, and possibly bipolar disorder or depression. PMID:25395965

  15. Circadian polymorphisms in night owls, in bipolars, and in non-24-hour sleep cycles.

    PubMed

    Kripke, Daniel F; Klimecki, Walter T; Nievergelt, Caroline M; Rex, Katharine M; Murray, Sarah S; Shekhtman, Tatyana; Tranah, Gregory J; Loving, Richard T; Lee, Heon-Jeong; Rhee, Min Kyu; Shadan, Farhad F; Poceta, J Steven; Jamil, Shazia M; Kline, Lawrence E; Kelsoe, John R

    2014-10-01

    People called night owls habitually have late bedtimes and late times of arising, sometimes suffering a heritable circadian disturbance called delayed sleep phase syndrome (DSPS). Those with DSPS, those with more severe progressively-late non-24-hour sleep-wake cycles, and those with bipolar disorder may share genetic tendencies for slowed or delayed circadian cycles. We searched for polymorphisms associated with DSPS in a case-control study of DSPS research participants and a separate study of Sleep Center patients undergoing polysomnography. In 45 participants, we resequenced portions of 15 circadian genes to identify unknown polymorphisms that might be associated with DSPS, non-24-hour rhythms, or bipolar comorbidities. We then genotyped single nucleotide polymorphisms (SNPs) in both larger samples, using Illumina Golden Gate assays. Associations of SNPs with the DSPS phenotype and with the morningness-eveningness parametric phenotype were computed for both samples, then combined for meta-analyses. Delayed sleep and "eveningness" were inversely associated with loci in circadian genes NFIL3 (rs2482705) and RORC (rs3828057). A group of haplotypes overlapping BHLHE40 was associated with non-24-hour sleep-wake cycles, and less robustly, with delayed sleep and bipolar disorder (e.g., rs34883305, rs34870629, rs74439275, and rs3750275 were associated with n=37, p=4.58E-09, Bonferroni p=2.95E-06). Bright light and melatonin can palliate circadian disorders, and genetics may clarify the underlying circadian photoperiodic mechanisms. After further replication and identification of the causal polymorphisms, these findings may point to future treatments for DSPS, non-24-hour rhythms, and possibly bipolar disorder or depression. PMID:25395965

  16. Impedance and electrically evoked compound action potential (ECAP) drop within 24 hours after cochlear implantation.

    PubMed

    Chen, Joshua Kuang-Chao; Chuang, Ann Yi-Chiun; Sprinzl, Georg Mathias; Tung, Tao-Hsin; Li, Lieber Po-Hung

    2013-01-01

    Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈ 2.5 cm) and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001). There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes with long

  17. Impedance and Electrically Evoked Compound Action Potential (ECAP) Drop within 24 Hours after Cochlear Implantation

    PubMed Central

    Chen, Joshua Kuang-Chao; Chuang, Ann Yi-Chiun; Sprinzl, Georg Mathias; Tung, Tao-Hsin; Li, Lieber Po-Hung

    2013-01-01

    Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implantation due to factors associated with wound conditions. The study presented our experiences with regards to initial switch-on within 24 hours, and thus the findings about the milieus inside cochlea within the first few hours after cochlear implantation in terms of impedance/ECAP fluctuations. The charts of fifty-four subjects with profound hearing impairment were studied. A minimal invasive approach was used for cochlear implantation, characterized by a small skin incision (≈2.5 cm) and soft techniques for cochleostomy. Impedance/ECAP was measured intro-operatively and within 24 hours post-operatively. Initial mapping within 24 hours post-operatively was performed in all patients without major complications. Impedance/ECAP became significantly lower measured within 24 hours post-operatively as compared with intra-operatively (p<0.001). There were no differences between pre-operative and post-operative threshold for air-conduction hearing. A significant drop of impedance/ECAP in one day after cochlear implantation was revealed for the first time in human beings. Mechanisms could be related to the restoration of neuronal sensitivity to the electrical stimulation, and/or the interaction between the matrix enveloping the electrodes and the electrical stimulation of the initial switch-on. Less wound pain/swelling and soft techniques both contributed to the success of immediate initial mapping, which implied a stable micro-environment inside the cochlea despite electrodes insertion. Our research invites further studies to correlate initial impedance/ECAP changes with long

  18. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice

    PubMed Central

    Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-01-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders. PMID:27609090

  19. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice

    NASA Astrophysics Data System (ADS)

    Chu, Xixia; Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-09-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders.

  20. 24-hour-restraint stress induces long-term depressive-like phenotypes in mice.

    PubMed

    Chu, Xixia; Zhou, Ying; Hu, Zhiqiang; Lou, Jingyu; Song, Wei; Li, Jing; Liang, Xiao; Chen, Chen; Wang, Shuai; Yang, Beimeng; Chen, Lei; Zhang, Xu; Song, Jinjing; Dong, Yujie; Chen, Shiqing; He, Lin; Xie, Qingguo; Chen, Xiaoping; Li, Weidong

    2016-01-01

    There is an increasing risk of mental disorders, such as acute stress disorder (ASD), post-traumatic stress disorder (PTSD) and depression among survivors who were trapped in rubble during earthquake. Such long-term impaction of a single acute restraint stress has not been extensively explored. In this study, we subjected mice to 24-hour-restraint to simulate the trapping episode, and investigated the acute (2 days after the restraint) and long-term (35 days after the restraint) impacts. Surprisingly, we found that the mice displayed depression-like behaviors, decreased glucose uptake in brain and reduced adult hippocampal neurogenesis 35 days after the restraint. Differential expression profiling based on microarrays suggested that genes and pathways related to depression and other mental disorders were differentially expressed in both PFC and hippocampus. Furthermore, the depression-like phenotypes induced by 24-hour-restraint could be reversed by fluoxetine, a type of antidepressant drug. These findings demonstrated that a single severe stressful event could produce long-term depressive-like phenotypes. Moreover, the 24-hour-restraint stress mice could also be used for further studies on mood disorders. PMID:27609090

  1. Continuous 24-hour intraocular pressure monitoring for glaucoma--time for a paradigm change.

    PubMed

    Mansouri, K; Weinreb, R

    2012-01-01

    Glaucoma is the main cause of irreversible blindness and intraocular pressure (IOP) is its only modifiable risk factor. The importance of robust lowering of IOP for prevention of glaucoma onset and progression is well established. Although IOP is a dynamic parameter with individual circadian rhythms, current management usually relies on single IOP measurements during regular clinic hours performed a few times a year. Recent technological advances have provided clinicians with tools for continuous IOP monitoring during a 24 hour period in an ambulatory setting. There are two approaches being investigated. The first is permanent IOP monitoring through an implantable sensor and the other is temporary monitoring through a contact lens sensor. In this article, we discuss the shortcomings of the current gold standard for tonometry (Goldmann Applanation Tonometry) and the current experience with the first commercially available continuous 24 hour IOP monitoring technology (SENSIMED Triggerfish®); a telemetric contact lens sensor produced by a Swiss start-up company (Sensimed AG, Lausanne, Switzerland). Recent studies suggest that 24 hour continuous monitoring of IOP can be integrated into clinical practice and have the potential to contribute to the reduction of glaucoma-related vision loss.

  2. Self-Reported Sleep Disturbance is associated with Lower CD4 Count and 24-Hour Urinary Dopamine Levels in Ethnic Minority Women Living with HIV

    PubMed Central

    Seay, Julia S.; McIntosh, Roger; Fekete, Erin M.; Fletcher, Mary Ann; Kumar, Mahendra; Schneiderman, Neil; Antoni, Michael H.

    2013-01-01

    Background Sleep disturbance is associated with dopamine dysregulation, which can negatively impact immune status. Individuals living with HIV experience more sleep difficulties, and poor sleep may compound immune decrements associated with HIV infection. Little research has examined associations between sleep, dopamine, and immune status (CD4 count) in individuals with HIV. As ethnic minority women living with HIV (WLWH) are at heightened risk for HIV disease progression, we related sleep reports to both CD4 count and dopamine levels in a cohort of ethnic minority WLWH. Methods Participants were 139 low-income WLWH (ages 20–62; 78.3% African-American or Caribbean) who reported both overall sleep quality and sleep disturbance on the Pittsburgh Sleep Quality Index (PSQI). CD4 count and HIV viral load were measured via morning peripheral venous blood samples, and concentrations of dopamine were measured via 24-hour urine collection. Covariates included HIV viral load, length of time since HIV diagnosis, HAART adherence, perceived stress and depression. Results After controlling for all covariates, greater sleep disturbance was associated with significantly lower CD4 count (β = −.20, p = .03) and lower levels of dopamine (β = −.25, p = .04). Poorer overall sleep quality was marginally associated with lower CD4 count (β = −.16, p = .08), and was not associated with dopamine. Conclusion Our analyses suggest that sleep disturbance is independently related with immune status and dopamine levels in WLWH. Lower levels of dopamine may indicate neuroendocrine dysregulation and may impact immune and health status. Results highlight sleep disturbance rather than overall sleep quality as potentially salient to neuroendocrine and immune status in ethnic minority WLWH. PMID:23850225

  3. Bath water contamination with Legionella and nontuberculous mycobacteria in 24-hour home baths, hot springs, and public bathhouses of Nagano Prefecture, Japan.

    PubMed

    Kobayashi, Michiko; Oana, Kozue; Kawakami, Yoshiyuki

    2014-01-01

    Bath water samples were collected from 116 hot springs, 197 public bathhouses, and 38 24-hour home baths in Nagano Prefecture, Japan, during the period of April 2009 to November 2011, for determining the presence and extent of contamination with Legionella and nontuberculous mycobacteria. Cultures positive for Legionella were observed in 123 of the 3,314 bath water samples examined. The distribution and abundance of Legionella and/or combined contamination with Legionella and nontuberculous mycobacteria were investigated to clarify the contamination levels. The abundance of Legionella was demonstrated to correlate considerably with the levels of combined contamination with Legionella and nontuberculous mycobacteria. Legionella spp. were obtained from 61% of the water samples from 24-hour home baths, but only from 3% of the samples from public bathhouses and hot springs. This is despite the fact that a few outbreaks of Legionnaires' disease in Nagano Prefecture as well as other regions of Japan have been traced to bath water contamination. The comparatively higher rate of contamination of the 24-hour home baths is a matter of concern. It is therefore advisable to routinely implement good maintenance of the water basins, particularly of the 24-hour home baths.

  4. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion

    PubMed Central

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-01-01

    Abstract Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286–4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the

  5. Validation of triple pass 24-hour dietary recall in Ugandan children by simultaneous weighed food assessment

    PubMed Central

    Olupot-Olupot, Peter; Engoru, Charles; Ssenyondo, Tonny; Nteziyaremye, Julius; Amorut, Denis; Nakuya, Margaret; Arimi, Margaret; Frost, Gary; Maitland, Kathryn

    2016-01-01

    Background Undernutrition remains highly prevalent in African children, highlighting the need for accurately assessing dietary intake. In order to do so, the assessment method must be validated in the target population. A triple pass 24 hour dietary recall with volumetric portion size estimation has been described but not previously validated in African children. This study aimed to establish the relative validity of 24-hour dietary recalls of daily food consumption in healthy African children living in Mbale and Soroti, eastern Uganda compared to simultaneous weighed food records. Methods Quantitative assessment of daily food consumption by weighed food records followed by two independent assessments using triple pass 24-hour dietary recall on the following day. In conjunction with household measures and standard food sizes, volumes of liquid, dry rice, or play dough were used to aid portion size estimation. Inter-assessor agreement, and agreement with weighed food records was conducted primarily by Bland-Altman analysis and secondly by intraclass correlation coefficients and quartile cross-classification. Results 19 healthy children aged 6 months to 12 years were included in the study. Bland-Altman analysis showed 24-hour recall only marginally under-estimated energy (mean difference of 149kJ or 2.8%; limits of agreement -1618 to 1321kJ), protein (2.9g or 9.4%; -12.6 to 6.7g), and iron (0.43mg or 8.3%; -3.1 to 2.3mg). Quartile cross-classification was correct in 79% of cases for energy intake, and 89% for both protein and iron. The intraclass correlation coefficient between the separate dietary recalls for energy was 0.801 (95% CI, 0.429-0.933), indicating acceptable inter-observer agreement. Conclusions Dietary assessment using 24-hour dietary recall with volumetric portion size estimation resulted in similar and acceptable estimates of dietary intake compared with weighed food records and thus is considered a valid method for daily dietary intake assessment of

  6. Static stretching can impair explosive performance for at least 24 hours.

    PubMed

    Haddad, Monoem; Dridi, Amir; Chtara, Moktar; Chaouachi, Anis; Wong, Del P; Behm, David; Chamari, Karim

    2014-01-01

    The aim of this study was to compare the effects of static vs. dynamic stretching (DS) on explosive performances and repeated sprint ability (RSA) after a 24-hour delay. Sixteen young male soccer players performed 15 minutes of static stretching (SS), DS, or a no-stretch control condition (CC) 24 hours before performing explosive performances and RSA tests. This was a within-subject repeated measures study with SS, DS, and CC being counterbalanced. Stretching protocols included 2 sets of 7 minutes 30 seconds (2 repetitions of 30 seconds with a 15-second passive recovery) for 5 muscle groups (quadriceps, hamstring, calves, adductors, and hip flexors). Twenty-four hours later (without any kind of stretching in warm-up), the players were tested for the 30-m sprint test (with 10- and 20-m lap times), 5 jump test (5JT), and RSA test. Significant differences were observed between CC, SS, and DS with 5JT (F = 9.99, p < 0.00, effect size [ES] = 0.40), 10-m sprint time (F = 46.52, p < 0.00, ES = 0.76), 20-m sprint time (F = 18.44, p < 0.000, ES = 0.55), and 30-m sprint time (F = 34.25, p < 0.000, ES = 0.70). The significantly better performance (p < 0.05) was observed after DS as compared with that after CC and SS in 5JT, and sprint times for 10, 20, and 30 m. In contrast, significantly worse performance (p < 0.05) was observed after SS as compared with that after CC in 5JT, and sprint times for 10, 20, and 30 m. With RSA, no significant difference was observed between different stretching protocols in the total time (F = 1.55, p > 0.05), average time (F = 1.53, p > 0.05), and fastest time (F = 2.30, p > 0.05), except for the decline index (F = 3.54, p < 0.04, ES = 0.19). Therefore, the SS of the lower limbs and hip muscles had a negative effect on explosive performances up to 24 hours poststretching with no major effects on the RSA. Conversely, the DS of the same muscle groups are highly recommended 24 hours before performing sprint and long-jump performances. In

  7. Changes in platelet morphology and function during 24 hours of storage.

    PubMed

    Braune, S; Walter, M; Schulze, F; Lendlein, A; Jung, F

    2014-01-01

    aggregates could be visualized microscopically. After four hours, first debris and very small aggregates occurred. After 24 hours, platelet aggregates and also debris progressively increased. In accordance to this, the CASY system revealed an increase of platelet aggregates (up to 90 μm diameter) with increasing storage time. The percentage of CD62P positive platelets and PF4 increased significantly with storage time in resting PRP. When soluble ADP was added to stored PRP samples, the number of activatable platelets decreased significantly over storage time. The present study reveals the importance of a consequent standardization in the preparation of WB and PRP. Platelet morphology and function, particularly platelet reactivity to adherent or soluble agonists in their surrounding milieu, changed rapidly outside the vascular system. This knowledge is of crucial interest, particularly in the field of biomaterial development for cardiovascular applications, and may help to define common standards in the in vitro hemocompatibility testing of biomaterials.

  8. Comparative studies on 24-hour urinary excretion in Japanese and Chinese adults and children--need for nutritional education.

    PubMed

    Mori, Mari; Xu, Jin-Wen; Mori, Hideki; Ling, Cheng Feng; Wei, Guo Hong; Yamori, Yukio

    2009-01-01

    In order to evaluate the effect of nutritional education on the risk of developing lifestyle-related diseases, we measured taurine and isoflavone content in 24-hour urine samples (24-U) of 3rd grade Chinese children (CC) and of age-matched Japanese children (JC), as well as adult Chinese and Japanese (CA, JA) according to the WHO-CARDIAC (Cardiovascular Diseases and Alimentary Comparison) Study protocol. There was a significantly higher prevalence of obesity and "thin" individuals in CC compared with JC. While K intake was not significantly different in the children, the sodium to potassium ratio (Na/ K) and the intake of sodium chloride (NaCl) were significantly higher in CC than in JC. Taurine excretion (24-U) was significantly higher in CC than in JC, but isoflavone excretion was significantly lower in CC than in JC. Taurine excretion was significantly lower in CA than in JA, while isoflavone excretion was almost the same in CA and JA. After nutritional education CC consumed more isoflavones than the control group that had been subjected to only environmental education. JC exhibited significantly higher 24-U taurine and isoflavone excretion after taking the nutritional class.

  9. Complementary nutrient effects of separately collected human faeces and urine on the yield and nutrient uptake of spinach (Spinacia oleracea).

    PubMed

    Kutu, Funso R; Muchaonyerwa, Pardon; Mnkeni, Pearson N S

    2011-05-01

    A glasshouse experiment was conducted to evaluate the combined use of separately collected human faeces and urine as fertilizer for spinach (Spinacia oleracea) production. Seven human faeces N : urine N combinations (1 : 7 to 7 : 1) each supplying 200 kg N ha(-1) were evaluated along with sole human faeces, sole urine, inorganic fertilizer and an unamended control. Complementary application of the two resources, human faeces and urine, increased fresh and dry matter yields only in treatments having high proportions of urine. Nitrogen uptake followed the same trend but the opposite trend occurred for P uptake indicating that urine was a better source of N whereas human faeces were the better source of P. Potassium uptake was not influenced by the two resources. The minimal improvement observed in the fertilizer value of human faeces when co-applied with urine suggested that co-application of the two resources may not give an added yield advantage when compared with sole human faeces.

  10. Development and validity of a 3-day smartphone-assisted 24-hour recall to assess beverage consumption in a Chinese population: a randomized cross-over study

    PubMed Central

    Smith, Lindsey P.; Hua, Jenna; Seto, Edmund; Du, Shufa; Zang, Jiajie; Zou, Shurong; Popkin, Barry M.; Mendez, Michelle A.

    2014-01-01

    This paper addresses the need for diet assessment methods that capture the rapidly changing beverage consumption patterns in China. The objective of this study was to develop a 3-day smartphone-assisted 24-hour recall to improve the quantification of beverage intake amongst young Chinese adults (n=110) and validate, in a small subset (n=34), the extent to which the written record and smartphone-assisted recalls adequately estimated total fluid intake, using 24-hour urine samples. The smartphone-assisted method showed improved validity compared to the written-assisted method, when comparing reported total fluid intake to total urine volume. However, participants reported consuming fewer beverages on the smartphone-assisted method compared to the written-assisted method, primarily due to decreased consumption of traditional zero-energy beverages (i.e. water, tea) in the smartphone-assisted method. It is unclear why participants reported fewer beverages in the smartphone-assisted method than the written-assisted method. One possibility is that participants found the smartphone method too cumbersome, and responded by decreasing beverage intake. These results suggest that smartphone-assisted 24-hour recalls perform comparably but do not appear to substantially improve beverage quantification compared to the current written record based approach. In addition, we piloted a beverage screener to identify consumers of episodically consumed SSBs. As expected, a substantially higher proportion of consumers reported consuming SSBs on the beverage screener compared to either recall type, suggesting that a beverage screener may be useful in characterizing consumption of episodically consumed beverages in China’s dynamic food and beverage landscape. PMID:25516327

  11. Usefulness of short-term urine collection in the nutritional monitoring of low birthweight infants.

    PubMed

    Boehm, G; Wiener, M; Schmidt, C; Ungethüm, A; Ungethüm, B; Moro, G

    1998-03-01

    To establish adequacy of urine collection times shorter than 24h in the metabolic monitoring of low birthweight infants, we collected urine for 24 h in 39 LBW infants during the third and fourth week of life. All urine voidings over the 24-h period were separately collected, the volume of each sampling and the time of voiding were recorded, and 20% of the volume was removed for pooling. All individual and pooled samples were analysed for total nitrogen, urea and ammonia, alpha-amino nitrogen, creatinine, sodium, potassium, calcium and phosphorus, and for each compound the ratio to 1 mol creatinine was established. Individual sample results were "pooled" to obtain 3-, 6- and 12-h period excretion and than related to the 24-h excretion as measured in the pooled 24-h sample. As the volume of urine obtained in any 6-h collecting period depended on the time of sampling (06:00-12:00 h, 17.5+/-3.1% of total; 12:00-18:00 h, 31.6+/-5.1% of total; 18:00-24:00 h, 25.6+/-3.1% of total; and 0:00-06:00h, 25.3+/-2.9% of total), calculations were based on samples obtained from 18:00 to 06:00 h. The correlation between results of 3- and 24 h-collection periods was weakest, while results of the 6-h collection correlated highly with the total daily excretion (r = between 0.82 and 0.93 for the different compounds) and the correlation was only slightly better when the 12-h collection period was considered. The correlation between the mean molar substrate/creatinine ratio of all individual samples of a 24-h collecting period and the and total daily excretion of the respective substrate was weaker (r = between 0.46 and 0.76 for the different compounds) than the correlation between the results of a 6-h collecting period and the daily excretion is not as stable than in later life. The data indicate that 6-h urine sampling may be sufficient for metabolic monitoring of LBW infants. By contrast, urinary substrate/creatinine ratios are not good markers of the daily excretions of the respective

  12. Optimal Method of Collection of First-Void Urine for Diagnosis of Chlamydia trachomatis Infection in Men▿

    PubMed Central

    Wisniewski, Craig A.; White, John A.; Michel, Claude-Edouard C.; Mahilum-Tapay, Lourdes; Magbanua, Jose Paolo V.; Nadala, Elpidio Cesar B.; Barber, Penelope J.; Goh, Beng T.; Lee, Helen H.

    2008-01-01

    First-void urine (FVU) is the preferred specimen for the diagnosis of urogenital Chlamydia trachomatis infection in men. We have developed FirstBurst, a urine collection device that collects the first 4 to 5 ml of FVU and yields a specimen with a sixfold higher C. trachomatis organism load than the regular urine cup by quantitative PCR (32,533 versus 5,271 plasmids/ml; P < 0.0001). Consequently, the use of FirstBurst to collect a urine sample improved the sensitivity of a rapid test for Chlamydia over testing of samples collected with a urine cup (82 versus 47% sensitivity using PCR as a reference; P < 0.0015). PMID:18234860

  13. [Electrocardiographic recording of long duration (Holter) of 24 hours during idiopathic cardiomyopathy of the peripartum].

    PubMed

    Diao, M; Diop, I B; Kane, A; Camara, S; Kane, Ad; Sarr, M; Ba, S A; Diouf, S M

    2004-01-01

    The idiopathic myocardiopathy of the peripartum (IMPP) is a frequent disease in the Soudano-Sahelian zone of Africa whose evolution is loaded with many complications hemodynamic, thrombo-embolic and rhythmic. The prevalence and the meaning of the rhythm disorders are unknown. The aims of this prospective study are to measure and to describe the prevalence of the anomalies observed in Holter ECG of 24 hours. It's about a description cross-sectional study realized at the Cardiology Department (CHU Dakar) and 19 patients with IMPP were included, from October 2000 to July 2002. A recording ECG of 24 hours (Holter) was realized on all the patients. The average age was 29.4+/-6.9 years with a low socio-economic level (100%). The diagnosis of IMPP done before childbirth in 4 cases (21%) and the post partum on 15 patients (78.9%). The dyspnea was constant, the chest pain in 12 cases (63.1%) and palpitations in 8 cases (42%). The average rate of hemoglobin was of 10.85+/-2.05 g/dL. The standard electrocardiogram recorded a sinusal tachycardia (68.4%), a cavitary hypertrophy (78.8%), and disorders of the repolarization (47.3%). The cardiac echo-Doppler noted a cavitary dilatation (84.2%), a constant alteration of the left ventricular systolic function with a fraction of average ejection of 29.7+/-10.3%. The anatomy of the valves was normal. The recording Holter ECG of 24 hours recorded a sinusal tachycardia in 17 cases (89.4%), ventricular extrasystoles on 7 patients (36.8%), 4 cases of ventricular tachycardia non-sustained and double ventricular extrasystole on 1 patient, auricular extrasystoles in 4 cases (21%) and 1 case of auriculo-ventricular block of the first degree. The study of heart rate variability founded a mean value of 106 ms.

  14. Development of an artificial placenta IV: 24 hour venovenous extracorporeal life support in premature lambs.

    PubMed

    Gray, Brian W; El-Sabbagh, Ahmed; Rojas-Pena, Alvaro; Kim, Anne C; Gadepali, Samir; Koch, Kely L; Capizzani, Tony R; Bartlet, Robert H; Mychaliska, George B

    2012-01-01

    An extracorporeal artificial placenta would change the paradigm of treating extremely premature infants. We hypothesized that a venovenous extracorporeal life support (VV-ECLS) artificial placenta would maintain fetal circulation, hemodynamic stability, and adequate gas exchange for 24 hours. A near-term neonatal lamb model (130 days; term = 145 days) was used (n = 9). The right jugular vein was cannulated for VV-ECLS outflow, and an umbilical vein was used for inflow. The circuit included a peristaltic roller pump and a 0.5 m(2) hollow fiber oxygenator. Lambs were maintained on VV-ECLS in an "amniotic bath" for up to 24 hours. Five of nine fetuses survived for 24 hours. In the survivors, average mean arterial pressure was 69 ± 10 mm Hg for the first 4 hours and 36 ± 8 mm Hg for the remaining 20 hours. The mean fetal heart rate was 202 ± 30. Mean VV-ECLS flow was 94 ± 20 ml/kg/min. Using a gas mixture of 50% O(2)/3% CO(2) and sweep flow of 1-2 L/min, the mean pH was 7.27 ± 0.09, with Po(2) of 35 ± 12 mm Hg and Pco(2) of 48 ± 12 mm Hg. Necropsy revealed a patent ductus arteriosus in all cases, and there was no gross or microscopic intracranial hemorrhage. Complications in failed attempts included technically difficult cannulation and multisystem organ failure. Future studies will enhance stability and address the factors necessary for long-term support.

  15. Treating allergic conjunctivitis: A once-daily medication that provides 24-hour symptom relief

    PubMed Central

    Schaeffer, Jack; Donnenfeld, Eric

    2016-01-01

    Background: Allergic conjunctivitis (AC) is a common ocular inflammatory manifestation of allergen exposure in sensitized individuals. Signs and symptoms of AC can decrease quality of life, interfere with productivity, and lead to considerable economic burden. Consistent suppression of conjunctival inflammation is necessary for managing AC, but currently available medications require frequent administration and exhibit limited duration of action. Methods: In this review, we summarized AC pathogenesis, diagnosis, and current treatment options as well as their limitations. Findings from the literature were discussed in the context of the unmet need for a once-daily medication with sustained 24-hour effectiveness. Results: Topical pharmacologic treatments are the most common approach for managing extant AC; however, most available medications require multiple daily instillations. Dual-acting antihistamine-mast cell stabilizing agents are currently considered first-line therapeutics for AC because they provide acute relief of signs and symptoms and block persistent inflammation to promote regression of AC. Recent studies of a newly-developed, higher-concentration formulation of a dual-acting antihistamine-mast cell stabilizer have demonstrated that this formulation provides a 24-hour duration of action with once-daily dosing. Conclusions: Dual-acting AC medications exhibit a high degree of overall effectiveness and are well tolerated for chronic use. A newly available once-daily medication that manages signs and symptoms of AC for a full 24 hours may be considered a treatment of choice for patients experiencing seasonal or perennial AC. ClinicalTrials.gov NCT01743027 and NCT01479374 PMID:27466061

  16. Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions

    PubMed Central

    McVey, Elaine; Keith, Steven; Herr, Joshua K.; Sutter, Diane; Pettis, Ronald J.

    2015-01-01

    Background: This study sought to assess the function and delivery reliability of intradermal (ID) infusion sets used with commercial insulin pumps. Method: Healthy subjects (n = 43) were randomized to either ID or subcutaneous (SC) arms, and received basal/bolus placebo delivery for 24 hours. Subjects received 4 of 8 infusion set combinations (ID: microneedle design A or B, with 2 pump brands [Animas or MiniMed]; SC: Teflon Quickset or steel Rapid-D, Animas pump only, with or without overtaping) and were evaluated for pump occlusion alarms, fluid leakage, pain, and tissue tolerability. A novel algorithm was developed to determine flow consistency based on fluid pressure, and the duration and occurrence rate for periods of unalarmed but interrupted flow (“silent occlusions’”) were compared. Results: ID delivery was successfully maintained over the 24-hour infusion period. The number of silent occlusions was lower for ID microneedle cannula design B than A (P < .01) and lower for Rapid-D SC device compared to Quick-set (P = .03). There was no significant difference in the number of occlusion alarms between the ID and SC devices with the Animas pump. However, the pumps tested with ID devices had significantly different alarm rates (MiniMed 29.5%, Animas 0%, P < .001). Leakage and tissue tolerability were comparable across devices. Conclusion: The ID infusion set reliably delivered diluent for an extended 24-hour period in healthy subjects and was well tolerated. Silent occlusion flow interruptions could be detected in both ID and SC infusion sets using a proprietary algorithm. This algorithm is a promising method for quantitatively evaluating infusion set flow performance. PMID:26319228

  17. 77 FR 65310 - Additional Air Quality Designations for the 2006 24-Hour Fine Particle National Ambient Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... the 2006 24-hour Fine Particle (PM 2.5 ) National Ambient Air Quality Standards,'' 74 FR 58688... Federal Regulations DC District of Columbia EO Executive Order EPA Environmental Protection Agency FR... EPA finalized designations for the 2006 24-hour PM 2.5 NAAQS (74 FR 58688, November 13, 2009), the...

  18. Assessing Dietary Intake in Childhood Cancer Survivors: Food Frequency Questionnaire Versus 24-Hour Diet Recalls.

    PubMed

    Zhang, Fang Fang; Roberts, Susan B; Must, Aviva; Wong, William W; Gilhooly, Cheryl H; Kelly, Michael J; Parsons, Susan K; Saltzman, Edward

    2015-10-01

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from Food Frequency Questionnaire (FFQ) and repeated 24-hour diet recalls (24HRs) against total energy expenditure (TEE) measured using the doubly labeled water method in 16 childhood cancer survivors. Dietary underreporting, assessed by (EI-TEE)/TEE × 100%, was 22% for FFQ and 1% for repeated 24HRs. FFQ significantly underestimates dietary intake and should not be used to assess the absolute intake of foods and nutrients in childhood cancer survivors.

  19. Intermittent short ECG recording is more effective than 24-hour Holter ECG in detection of arrhythmias

    PubMed Central

    2014-01-01

    Background Many patients report symptoms of palpitations or dizziness/presyncope. These patients are often referred for 24-hour Holter ECG, although the sensitivity for detecting relevant arrhythmias is comparatively low. Intermittent short ECG recording over a longer time period might be a convenient and more sensitive alternative. The objective of this study is to compare the efficacy of 24-hour Holter ECG with intermittent short ECG recording over four weeks to detect relevant arrhythmias in patients with palpitations or dizziness/presyncope. Methods Design: prospective, observational, cross-sectional study. Setting: Clinical Physiology, University Hospital. Patients: 108 consecutive patients referred for ambiguous palpitations or dizziness/presyncope. Interventions: All individuals underwent a 24-hour Holter ECG and additionally registered 30-second handheld ECG (Zenicor EKG® thumb) recordings at home, twice daily and when having cardiac symptoms, during 28 days. Main outcome measures: Significant arrhythmias: atrial fibrillation (AF), paroxysmal supraventricular tachycardia (PSVT), atrioventricular (AV) block II–III, sinus arrest (SA), wide complex tachycardia (WCT). Results 95 patients, 42 men and 53 women with a mean age of 54.1 years, completed registrations. Analysis of Holter registrations showed atrial fibrillation (AF) in two patients and atrioventricular (AV) block II in one patient (= 3.2% relevant arrhythmias [95% CI 1.1–8.9]). Intermittent handheld ECG detected nine patients with AF, three with paroxysmal supraventricular tachycardia (PSVT) and one with AV-block-II (= 13.7% relevant arrhythmias [95% CI 8.2–22.0]). There was a significant difference between the two methods in favour of intermittent ECG with regard to the ability to detect relevant arrhythmias (P = 0.0094). With Holter ECG, no symptoms were registered during any of the detected arrhythmias. With intermittent ECG, symptoms were registered during half of the arrhythmia

  20. Nutritional behavior of cyclists during a 24-hour team relay race: a field study report

    PubMed Central

    2012-01-01

    Background Information about behavior of energy intake in ultra-endurance cyclists during a 24-hour team relay race is scarce. The nutritional strategy during such an event is an important factor which athletes should plan carefully before the race. The purpose of this study was to examine and compare the nutritional intake of ultra-endurance cyclists during a 24-hour team relay race with the current nutritional guidelines for endurance events. Additionally, we analyzed the relationship among the nutritional and performance variables. Methods Using a observational design, nutritional intake of eight males (mean ± SD: 36.7 ± 4.7 years; 71.6 ± 4.9 kg; 174.6 ± 7.3 cm; BMI 23.5 ± 0.5 kg/m2) participating in a 24-hour team relay cycling race was assessed. All food and fluid intake by athletes were weighed and recorded. Additionally, distance and speed performed by each rider were also recorded. Furthermore, before to the race, all subjects carried out an incremental exercise test to determine two heart rate-VO2 regression equations which were used to estimate the energy expenditure. Results The mean ingestion of macronutrients during the event was 943 ± 245 g (13.1 ± 4.0 g/kg) of carbohydrates, 174 ± 146 g (2.4 ± 1.9 g/kg) of proteins and 107 ± 56 g (1.5 ± 0.7 g/kg) of lipids, respectively. This amount of nutrients reported an average nutrient intake of 22.8 ± 8.9 MJ which were significantly lower compared with energy expenditure 42.9 ± 6.8 MJ (P = 0.012). Average fluid consumption corresponded to 10497 ± 2654 mL. Mean caffeine ingestion was 142 ± 76 mg. Additionally, there was no relationship between the main nutritional variables (i.e. energy intake, carbohydrates, proteins, fluids and caffeine ingestion) and the main performance variables (i.e. distance and speed). Conclusions A 24-hour hours cycling competition in a team relay format elicited high energy demands which were not compensated by energy intake of the athletes despite that dietary

  1. Assessing Dietary Intake in Childhood Cancer Survivors: Food Frequency Questionnaire versus 24-Hour Diet Recalls

    PubMed Central

    Zhang, Fang Fang; Roberts, Susan B.; Must, Aviva; Wong, William W.; Gilhooly, Cheryl H.; Kelly, Michael J.; Parsons, lkSusan K.; Saltzman, Edward

    2015-01-01

    Cancer diagnosis and treatment may influence dietary intake. The validity of using self-reported methods to quantify dietary intake has not been evaluated in childhood cancer survivors. We validated total energy intake (EI) reported from food frequency questionnaire (FFQ) and repeated 24-hour diet recalls (24HRs) against total energy expenditure (TEE) measured using the doubly labeled water method in 16 childhood cancer survivors. Dietary underreporting, assessed by (EI-TEE)/TEE ×100%, was 22% for FFQ and 1% for repeated 24HRs. FFQ significantly underestimates dietary intake and should not be used to assess the absolute intake of foods and nutrients in childhood cancer survivors. PMID:25883059

  2. Comparison of urine collection methods for albuminuria assessment in young children.

    PubMed

    van den Belt, S M; Gracchi, V; de Zeeuw, D; Heerspink, H J L

    2016-07-01

    Cotton wool or pantyliners placed in a diaper can be used as urine collection devices for albuminuria measurements in young, not continent children. We tested a new collection method (PeeSpot(R)) for its analytical performance, and compared it with the pantyliner technique. Eighty-one urine samples with a wide range of albuminuria were pipetted on the pantyliner and PeeSpot in duplicate. These were incubated for 3h at 37°C (simulating the time a toddler wears a diaper), and subsequently 72h at room temperature (simulating transport to a central laboratory). Urine was extracted by centrifugation and albumin concentration (UAc) was measured. UAC measured by the two methods was compared with UAC in an unprocessed reference aliquot stored for 75h at 4°C. Bias (mean percentage UAC difference between test and reference), precision (interquartile range of the UAC difference) and accuracy (proportion of samples within 30% of reference UAC) were calculated. Median UAC in the reference aliquot was 66.0mg/L [IQR 25.0-211.0], pantyliner 32.0mg/L [4.7-165.0; P<0.001 vs reference], and PeeSpot 61.0mg/L [27.0-216.0; P=0.84 vs reference]. Bias, precision and accuracy in pantyliner were -34.2%, 31.3mg/L and 48.1%; in PeeSpot 3.3%, 5.0mg/L and 96.3%. Passing-Bablok regression and Bland-Altman plot showed an underestimation for the pantyliner but not for the PeeSpot. The PeeSpot is an accurate and precise tool for collecting urine for albumin measurement in young children and should be preferred over the alternative cotton wool collection technique. PMID:27129631

  3. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    PubMed Central

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  4. Regional Neurodegeneration and Gliosis Are Amplified by Mild Traumatic Brain Injury Repeated at 24-Hour Intervals

    PubMed Central

    Bolton, Amanda Nicholle; Saatman, Kathryn Eileen

    2014-01-01

    Most traumatic brain injuries (TBIs) that occur every year are classified as ‘mild’. Individuals involved in high-risk activities may sustain multiple mild TBIs. We evaluated the acute physiological and histopathological consequences of mild TBI in a mouse model, comparing sham injury, single impact, or 5 impacts at a 24- or 48-hour inter-injury interval. A single closed skull impact resulted in bilateral gliosis in the hippocampus and entorhinal cortex that was proportional to impact depth. Midline impact, at a depth just above the threshold to induce transient unconsciousness, produced occasional axonal injury and degenerating neurons accompanied by astrogliosis in the entorhinal cortex and cerebellum. Mild TBI repeated every 24 hours resulted in bilateral hemorrhagic lesions in the entorhinal cortex along with significantly increased neurodegeneration and microglial activation despite diminished durations of apnea and unconsciousness with subsequent impacts. Astrogliosis and diffusely distributed axonal injury were also observed bilaterally in the cerebellum and the brainstem. When the interval between mild TBIs was increased to 48 hours, the pathological consequences were comparable to a single TBI. Together, these data suggest that in mice the brain remains at increased risk for damage for 24 hours after mild TBI despite reduced acute physiological responses to subsequent mild impacts. PMID:25232942

  5. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns

    PubMed Central

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  6. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers.

    PubMed

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m(2), had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab(®) device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens(®) algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for "24-hour", "awake", and "asleep" periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects.

  7. A Compute Perspective: Delivering Decision Support Products in 24 Hours from the Airborne Snow Observatory

    NASA Astrophysics Data System (ADS)

    Ramirez, P.; Mattmann, C. A.; Painter, T. H.; Seidel, F. C.; Trangsrud, A.; Hart, A. F.; Goodale, C. E.; Boardman, J. W.; Heneghan, C.; Verma, R.; Khudikyan, S.; Boustani, M.; Zimdars, P. A.; Horn, J.; Neely, S.

    2013-12-01

    The JPL Airborne Snow Observatory (ASO) must process 100s of GB of raw data to 100s of Terabytes of derived data in 24 hour Near Real Time (NRT) latency in a geographically distributed mobile compute and data-intensive processing setting. ASO provides meaningful information to water resource managers in the Western US letting them know how much water to maintain; or release, and what the prospectus of the current snow season is in the Sierra Nevadas. Providing decision support products processed from airborne data in a 24 hour timeframe is an emergent field and required the team to develop a novel solution as this process is typically done over months. We've constructed a system that combines Apache OODT; with Apache Tika; with the Interactive Data Analysis (IDL)/ENVI programming environment to rapidly and unobtrusively generate, distribute and archive ASO data as soon as the plane lands near Mammoth Lakes, CA. Our system is flexible, underwent several redeployments and reconfigurations, and delivered this critical information to stakeholders during the recent "Snow On" campaign March 2013 - June 2013. This talk will take you through a day in the life of the compute team from data acquisition, delivery, processing, and dissemination. Within this context, we will discuss the architecture of ASO; the open source software we used; the data we stored; and how it was delivered to its users. Moreover we will discuss the logistics, system engineering, and staffing that went into the developing, deployment, and operation of the mobile compute system.

  8. Coagulation abnormalities in diabetic coma before and 24 hours after treatment.

    PubMed

    McLaren, E H; Cullen, D R; Brown, M J

    1979-12-01

    A coagulation screen consisting of measurement of the prothrombin time, thrombin time, kaolin caphalin clotting time, platelet count, plasma fibrinogen level, fibrin degradation products and ethanol gelation test was performed on 24 patients with impairment of consciousness due to acute diabetic metabolic decompensation at the start of treatment and 24 hours later. 22 out of 24 patients showed at least one coagulation abnormality on admission of which the commonest were a prolonged prothrombin time, shortened kaolin cephalin clotting.time and raised plasma fibrinogen level. After 24 hours of treatment these values were more normal but 20 out of 22 patients still displayed some abnormality. 15 patients had two or more coagulation abnormalities on admission including 3 patients with haematological abnormalities suggestive of disseminated intravascular coagulation. This group was older and had higher blood ureas than those with fewer abnormalities, but plasma glucose, sodium, potassium and bicarbonate levels were similar in both groups of patients. All 5 patients with hyperosmolar non-ketotic coma and all 3 patients who died without recovering consciousness had two or more coagulation abnormalities on admission.

  9. Deviation of innate circadian period from 24 hours reduces longevity in mice

    PubMed Central

    Libert, Sergiy; Bonkowski, Michael S.; Pointer, Kelli; Pletcher, Scott D.; Guarente, Leonard

    2012-01-01

    Summary The variation of individual lifespans, even in highly inbred cohorts of animals and under strictly controlled environmental conditions, is substantial and not well understood. This variation in part could be due to epigenetic variation, which later affects the animal’s physiology and ultimately longevity. Identification of the physiological properties that impact health and lifespan is crucial for longevity research and the development of anti-aging therapies. Here we measured individual circadian and metabolic characteristics in a cohort of inbred F1 hybrid mice and correlated these parameters to their lifespans. We found that mice with innate circadian periods close to 24 hours (revealed during 30 days of housing in total darkness) enjoyed nearly 20% longer lifespans than their littermates, which had shorter or longer innate circadian periods. These findings show that maintenance of a 24 hour intrinsic circadian period is a positive predictor of longevity. Our data suggest that circadian period may be used to predict individual longevity and that processes that control innate circadian period affect aging. PMID:22702406

  10. Sleep in healthy elderly subjects: a 24-hour ambulatory polysomnographic study.

    PubMed

    Gigli, G L; Placidi, F; Diomedi, M; Maschio, M; Silvestri, G; Scalise, A; Marciani, M G

    1996-04-01

    It is still debated whether the deterioration of the sleep pattern, frequently reported by elderly subjects, is due only to aging per se. Other factors associated with aging or modifications of biological rhythms could also be involved. Elderly subjects frequently complain of daytime sleepiness, but it is not clear whether this actually represents a return to a polyphasic structure of sleep, or only a consequence of a disturbed night sleep. Ten healthy, independent and active elderly subjects (age > 72 years) were elevated by means of 24-hour ambulatory polysomnography. Findings of nocturnal sleep were compared with sleep of the same group in the 24-hour period and with sleep of young healthy controls. We observed a fragmentation of nocturnal sleep, but a fairly good representation of stages and a preservation of cyclicity. Except for three cases, with early or late times of sleep onset and wake-up, sleep disruption did not seem to be related to modification of circadian rhythms. Only three subjects presented undesired daytime naps, whereas the others either did not show daytime sleep at all, or were used to having their siesta after lunch since their young adulthood. In normal aging, daytime sleep does not constitute a social problem. Ambulatory polysomnography is a valid alternative to laboratory recordings in the identification of daytime sleep. PMID:8734563

  11. The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns.

    PubMed

    Xu, Sarah C; Gauthier, Angela C; Liu, Ji

    2016-01-01

    Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. PMID:27525110

  12. PHYSICIAN-PHARMACIST CO-MANAGEMENT AND 24-HOUR BLOOD PRESSURE CONTROL

    PubMed Central

    Chen, Ziqian; Ernst, Michael E.; Ardery, Gail; Xu, Yinghui; Carter, Barry L.

    2013-01-01

    The objectives of this study were: to compare indices of 24-hour BP following a physician-pharmacist collaborative intervention and to describe the associated changes in antihypertensive medications. This was a secondary analysis of a prospective, cluster-randomized clinical trial conducted in 6 family medicine clinics randomized to co-managed (n=3 clinics, 176 subjects) or control (n=3 clinics, 198 subjects) groups. Mean ambulatory systolic BP was significantly lower in the co-managed versus the control group: daytime SBP 122.8 mm Hg versus 134.4 mm Hg (p<0.001); nighttime SBP 114.8 mm Hg versus 123.7 mm Hg (p<0.001); and 24-hour SBP 120.4 mm Hg versus 131.8 mm Hg (p<0.001), respectively. Significantly more drug changes were made in the co-managed than in the control group (2.7 versus 1.1 changes/subject, p<0.001), and there was greater diuretic use in co-managed subjects (79.6% versus 62.6%, p<0.001). Ambulatory BPs were significantly lower for the subjects who had a diuretic added during the first month compared with those who never had a diuretic added (p<0.01). Physician-pharmacist co-management significantly improved ambulatory BP compared with a control group. Anti-hypertensive drug therapy was intensified much more for subjects in the co-managed group. PMID:23614849

  13. The 24-hour pulse wave velocity, aortic augmentation index, and central blood pressure in normotensive volunteers.

    PubMed

    Kuznetsova, Tatyana Y; Korneva, Viktoria A; Bryantseva, Evgeniya N; Barkan, Vitaliy S; Orlov, Artemy V; Posokhov, Igor N; Rogoza, Anatoly N

    2014-01-01

    The purpose of this study was to examine the pulse wave velocity, aortic augmentation index corrected for heart rate 75 (AIx@75), and central systolic and diastolic blood pressure during 24-hour monitoring in normotensive volunteers. Overall, 467 subjects (206 men and 261 women) were recruited in this study. Participants were excluded from the study if they were less than 19 years of age, had blood test abnormalities, had a body mass index greater than 2 7.5 kg/m(2), had impaired glucose tolerance, or had hypotension or hypertension. Ambulatory blood pressure monitoring (ABPM) with the BPLab(®) device was performed in each subject. ABPM waveforms were analyzed using the special automatic Vasotens(®) algorithm, which allows the calculation of pulse wave velocity, AIx@75, central systolic and diastolic blood pressure for "24-hour", "awake", and "asleep" periods. Circadian rhythms and sex differences in these indexes were identified. Pending further validation in prospective outcome-based studies, our data may be used as preliminary diagnostic values for the BPLab ABPM additional index in adult subjects. PMID:24812515

  14. Urine specimen collection with external devices for diagnosis of bacteriuria in elderly incontinent men.

    PubMed

    Nicolle, L E; Harding, G K; Kennedy, J; McIntyre, M; Aoki, F; Murray, D

    1988-06-01

    We determined the validity of using external devices for urine specimen collection from 24 elderly incontinent men residing in a nursing home by collecting three sequential specimens, two with external devices and then one by catheterization. The positive predictive value of organisms isolated in quantitative counts of greater than or equal to 10(5) CFU/ml in external devices for bladder bacteriuria was 86% for either sterile or clean collecting devices and 93% for the same organism in two consecutive specimens. The negative predictive value for organisms present in quantitative counts of less than 10(5) CFU/ml was 90% for both sterile and clean devices and 86% when the organism was present in both specimens. Contamination in external collection devices was not influenced by whether the device was clean or sterile, circumcision of the resident, or duration of time between device application and specimen collection. These data suggest that urine specimens collected by ward nursing staff with external devices are reliable for the diagnosis of bacteriuria in this patient population. PMID:3384923

  15. Cytological features of carcinoma of the collecting ducts of Bellini in voided urine cytology.

    PubMed

    Ohsaki, Hiroyuki; Hirakawa, Eiichiro; Kushida, Yoshio; Kadota, Kyuichi; Ishikawa, Masashi; Haba, Reiji

    2009-09-01

    Carcinoma of the collecting ducts of Bellini (CCDB) is a rare histological type of renal cell carcinoma. This article describes the cytological features of CCDB in voided urine, confirmed on the basis of the histopathology and immunohistochemistry. The CCDB cells occurred singly in loose aggregates and in small clusters, occasionally in a rosette-like structure. There were various types of cancer cells, including round to oval, spindle, and tadpole-like cells. The nuclei usually showed coarse chromatin, inconspicuous nucleoli, and lacy to vacuolated cytoplasm. CCDB of the kidney is a rare cytodiagnostic challenge in voided urine cytology alone. When the cytological diagnosis is considered, it is necessary to perform immunocytochemistry and correlate the clinical history and imaging studies.

  16. Drug Use on Mont Blanc: A Study Using Automated Urine Collection

    PubMed Central

    Robach, Paul; Trebes, Gilles; Lasne, Françoise; Buisson, Corinne; Méchin, Nathalie; Mazzarino, Monica; de la Torre, Xavier; Roustit, Matthieu; Kérivel, Patricia; Botré, Francesco; Bouzat, Pierre

    2016-01-01

    Mont Blanc, the summit of Western Europe, is a popular but demanding high-altitude ascent. Drug use is thought to be widespread among climbers attempting this summit, not only to prevent altitude illnesses, but also to boost physical and/or psychological capacities. This practice may be unsafe in this remote alpine environment. However, robust data on medication during the ascent of Mont Blanc are lacking. Individual urine samples from male climbers using urinals in mountain refuges on access routes to Mont Blanc (Goûter and Cosmiques mountain huts) were blindly and anonymously collected using a hidden automatic sampler. Urine samples were screened for a wide range of drugs, including diuretics, glucocorticoids, stimulants, hypnotics and phosphodiesterase 5 (PDE-5) inhibitors. Out of 430 samples analyzed from both huts, 35.8% contained at least one drug. Diuretics (22.7%) and hypnotics (12.9%) were the most frequently detected drugs, while glucocorticoids (3.5%) and stimulants (3.1%) were less commonly detected. None of the samples contained PDE-5 inhibitors. Two substances were predominant: the diuretic acetazolamide (20.6%) and the hypnotic zolpidem (8.4%). Thirty three samples were found positive for at least two substances, the most frequent combination being acetazolamide and a hypnotic (2.1%). Based on a novel sampling technique, we demonstrate that about one third of the urine samples collected from a random sample of male climbers contained one or several drugs, suggesting frequent drug use amongst climbers ascending Mont Blanc. Our data suggest that medication primarily aims at mitigating the symptoms of altitude illnesses, rather than enhancing performance. In this hazardous environment, the relatively high prevalence of hypnotics must be highlighted, since these molecules may alter vigilance. PMID:27253728

  17. Drug Use on Mont Blanc: A Study Using Automated Urine Collection.

    PubMed

    Robach, Paul; Trebes, Gilles; Lasne, Françoise; Buisson, Corinne; Méchin, Nathalie; Mazzarino, Monica; de la Torre, Xavier; Roustit, Matthieu; Kérivel, Patricia; Botré, Francesco; Bouzat, Pierre

    2016-01-01

    Mont Blanc, the summit of Western Europe, is a popular but demanding high-altitude ascent. Drug use is thought to be widespread among climbers attempting this summit, not only to prevent altitude illnesses, but also to boost physical and/or psychological capacities. This practice may be unsafe in this remote alpine environment. However, robust data on medication during the ascent of Mont Blanc are lacking. Individual urine samples from male climbers using urinals in mountain refuges on access routes to Mont Blanc (Goûter and Cosmiques mountain huts) were blindly and anonymously collected using a hidden automatic sampler. Urine samples were screened for a wide range of drugs, including diuretics, glucocorticoids, stimulants, hypnotics and phosphodiesterase 5 (PDE-5) inhibitors. Out of 430 samples analyzed from both huts, 35.8% contained at least one drug. Diuretics (22.7%) and hypnotics (12.9%) were the most frequently detected drugs, while glucocorticoids (3.5%) and stimulants (3.1%) were less commonly detected. None of the samples contained PDE-5 inhibitors. Two substances were predominant: the diuretic acetazolamide (20.6%) and the hypnotic zolpidem (8.4%). Thirty three samples were found positive for at least two substances, the most frequent combination being acetazolamide and a hypnotic (2.1%). Based on a novel sampling technique, we demonstrate that about one third of the urine samples collected from a random sample of male climbers contained one or several drugs, suggesting frequent drug use amongst climbers ascending Mont Blanc. Our data suggest that medication primarily aims at mitigating the symptoms of altitude illnesses, rather than enhancing performance. In this hazardous environment, the relatively high prevalence of hypnotics must be highlighted, since these molecules may alter vigilance. PMID:27253728

  18. Validation of a Novel Collection Device for Non-Invasive Urine Sampling from Free-Ranging Animals

    PubMed Central

    Danish, Lisa Michelle; Heistermann, Michael; Agil, Muhammad; Engelhardt, Antje

    2015-01-01

    Recent advances in non-invasively collected samples have opened up new and exciting opportunities for wildlife research. Different types of samples, however, involve different limitations and certain physiological markers (e.g., C-peptide, oxytocin) can only be reliably measured from urine. Common collection methods for urine to date work best for arboreal animals and large volumes of urine. Sufficient recovery of urine is thus still difficult for wildlife biologists, particularly for terrestrial and small bodied animals. We tested three collection devices (two commercially available saliva swabs, Salivette synthetic and cotton, and cotton First aid swabs) against a control to permit the collection of small volumes of urine from the ground. We collected urine samples from captive and wild macaques, and humans, measured volume recovery, and analyzed concentrates of selected physiological markers (creatinine, C-peptide, and neopterin). The Salivette synthetic device was superior to the two alternative devices. Concentrations of creatinine, absolute C-peptide, C-peptide per creatinine, absolute neopterin, and neopterin per creatinine measured in samples collected with this device did not differ significantly from the control and were also strongly correlated to it. Fluid recovery was also best for this device. The least suitable device is the First aid collection device; we found that while absolute C-peptide and C-peptide per creatinine concentrations did not differ significantly from the control, creatinine concentrations were significantly lower than the control. In addition, these concentrations were either not or weakly correlated to the control. The Salivette cotton device provided intermediate results, although these concentrations were strongly correlated to the control. Salivette synthetic swabs seem to be useful devices for the collection of small amounts of urine from the ground destined for the assessment of physiological parameters. They thus provide new

  19. Turbulent diffusion on the solar photosphere through 24-hour continuous observations of magnetic elements

    NASA Astrophysics Data System (ADS)

    Giannattasio, F.; Berrilli, F.; Del Moro, D.; Bellot Rubio, L.; Orozco Suarez, D.; Gosic, M.

    2012-12-01

    Solar atmosphere is a unique laboratory for the study of turbulent flows under extreme conditions (e.g. very high Reynolds numbers). The turbulent nature of the flow may be approached by determining how magnetic flux elements are transported on the solar surface, and measuring the spatio-temporal scales on which these small magnetic structures are organized. The process involved is diffusion. Several works explored this topic, both by simulations and observations, and the results are often contradictory, ranging from fully-developed turbulent scenarios to normal-diffusive motions. We analyze 24-hour continuous Hinode SOT observations of a supergranular region (for the first time these long scales are explored), studying the evolution of the mutual distance between magnetic element pairs and its scaling laws, in order to investigate the diffusion process. We find a super-diffusive behavior, with a gamma index depending on the spatial scale selected.

  20. Chest physiotherapy in preterm infants with RDS in the first 24 hours of life.

    PubMed

    Raval, D; Yeh, T F; Mora, A; Cuevas, D; Pyati, S; Pildes, R S

    1987-01-01

    To evaluate if chest physiotherapy is beneficial to premature infants with respiratory distress syndrome (RDS) during the first 24 hours of life, 20 infants were randomly assigned to two groups; 10 infants in Group I received routine chest physiotherapy and suction, and 10 infants in Group II received suction only. The birth weight, gestational age, postnatal age, Apgar scores, blood gases, acid-base status, and ventilatory requirements prior to study were comparable between the two groups. There were no significant differences between the groups in the amount of endotracheal secretions removed, the PO2/FIO2 ratio, blood gases, and pH during the study. The incidence of patent ductus arteriosus (PDA), bronchopulmonary dysplasia (BPD), Grade I and II intraventricular hemorrhage (IVH), and mortality was comparable. However, five of 10 Group I and zero of 10 Group II infants developed Grade III or IV IVH (P less than 0.05).

  1. [Development of direct and indirect ambulatory 24-hour blood pressure monitoring].

    PubMed

    Krönig, B

    1991-01-01

    The direct ambulatory 24-hour blood-pressure monitoring has been applied in two ways. With the so called "Oxford-system", blood pressure is recorded via a cannula in the brachial artery which is connected to a perfusion unit that is worn around the neck, on the front of the chest, with a tape recorder carried in a pouch on the patient's belt. Using the micro-catheter blood-pressure telemetry recording is done in the same way, but transmission of the data to a stationary-receiving unit is managed by telemetry. The usage of the latter method is limited by the weight and complexity of the patient-sited equipment. Compared to the Oxford-system there is the advantage of continuously observing the patients blood-pressure "on-line" during the recording. The invasive character of both methods limits the application to special, scientific investigations. In recent years the indirect recording machines for 24-hour blood-pressure monitoring has been developed further. They are now accurate, easy to apply and simple to work out. Beside the auscultatory way of recording, with or without ECG-gating, the oscillometry recording machines have been improved. There should be automatically-operated intervals with recordings in day-time every 15-20 minutes and during the night every 30 minutes. The recorded data should be analysed by computer, calculating mean values with standard deviations in day-time and night-time separately. Further more, there should be a listing of reading-errors and probably corrected measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Ambulatory arterial stiffness index derived from 24-hour ambulatory blood pressure monitoring.

    PubMed

    Li, Yan; Wang, Ji-Guang; Dolan, Eamon; Gao, Ping-Jin; Guo, Hui-Feng; Nawrot, Tim; Stanton, Alice V; Zhu, Ding-Liang; O'Brien, Eoin; Staessen, Jan A

    2006-03-01

    We hypothesized that 1 minus the slope of diastolic on systolic pressure during 24-hour ambulatory monitoring (ambulatory arterial stiffness index [AASI]) might reflect arterial stiffness. We compared AASI with established measures of arterial stiffness and studied its distribution in Chinese and European populations. We used 90207 SpaceLabs monitors and the SphygmoCor device to measure AASI, central and peripheral pulse pressures, the central (CAIx) and peripheral (PAIx) systolic augmentation indexes, and aortic pulse wave velocity. In 166 volunteers, the correlation coefficient between AASI and pulse wave velocity was 0.51 (P<0.0001). In 348 randomly recruited Chinese subjects, AASI correlated (P<0.0001) with CAIx (r=0.48), PAIx (r=0.50), and central pulse pressure (r=0.50). AASI increased with age and mean arterial pressure but decreased with body height. Both before and after adjustment for arterial wave reflections by considering height and heart rate as covariates, AASI correlated more (P<0.0001) closely with CAIx and PAIx than 24-hour pulse pressure. Among normotensive subjects, the 95th percentile of AASI was 0.55 in Chinese and 0.57 in 1617 Europeans enrolled in the International Database on Ambulatory Blood Pressure Monitoring. The upper boundary of the 95% prediction interval of AASI in relation to age ranged from 0.53 at 20 years to 0.72 at 80 years. In conclusion, AASI is a new index of arterial stiffness that can be easily measured under ambulatory conditions. Pending additional validation in outcome studies, normal values of AASI are probably <0.50 and 0.70 in young and older subjects, respectively. PMID:16432048

  3. A 24-Hour Study of the Hypothalamo-Pituitary Axes in Huntington’s Disease

    PubMed Central

    Nambron, Rajasree; Costelloe, Seán J.; Martin, Nicholas G.; Hill, Nathan R.; Frost, Chris; Watt, Hilary C.; Hindmarsh, Peter; Björkqvist, Maria; Warner, Thomas T.

    2015-01-01

    Background Huntington’s disease is an inherited neurodegenerative disorder characterised by motor, cognitive and psychiatric disturbances. Patients exhibit other symptoms including sleep and mood disturbances, muscle atrophy and weight loss which may be linked to hypothalamic pathology and dysfunction of hypothalamo-pituitary axes. Methods We studied neuroendocrine profiles of corticotropic, somatotropic and gonadotropic hypothalamo-pituitary axes hormones over a 24-hour period in controlled environment in 15 healthy controls, 14 premanifest and 13 stage II/III Huntington’s disease subjects. We also quantified fasting levels of vasopressin, oestradiol, testosterone, dehydroepiandrosterone sulphate, thyroid stimulating hormone, free triiodothyronine, free total thyroxine, prolactin, adrenaline and noradrenaline. Somatotropic axis hormones, growth hormone releasing hormone, insulin-like growth factor-1 and insulin-like factor binding protein-3 were quantified at 06:00 (fasting), 15:00 and 23:00. A battery of clinical tests, including neurological rating and function scales were performed. Results 24-hour concentrations of adrenocorticotropic hormone, cortisol, luteinizing hormone and follicle-stimulating hormone did not differ significantly between the Huntington’s disease group and controls. Daytime growth hormone secretion was similar in control and Huntington’s disease subjects. Stage II/III Huntington’s disease subjects had lower concentration of post-sleep growth hormone pulse and higher insulin-like growth factor-1:growth hormone ratio which did not reach significance. In Huntington’s disease subjects, baseline levels of hypothalamo-pituitary axis hormones measured did not significantly differ from those of healthy controls. Conclusions The relatively small subject group means that the study may not detect subtle perturbations in hormone concentrations. A targeted study of the somatotropic axis in larger cohorts may be warranted. However, the lack

  4. Low correlation between visit-to-visit variability and 24-hour variability of blood pressure

    PubMed Central

    Muntner, Paul; Shimbo, Daichi; Diaz, Keith M.; Newman, Jonathan; Sloan, Richard P.; Schwartz, Joseph E.

    2013-01-01

    Visit-to-visit variability (VVV) of clinic systolic blood pressure (SBP) has been associated with cardiovascular disease risk. Given the need for obtaining blood pressure (BP) at multiple visits to calculate VVV, substituting BP variability from ambulatory blood pressure monitoring (ABPM) may be a practical alternative. We assessed the correlation between VVV of BP and BP variability from ABPM using data from 146 untreated, mostly normotensive participants (mean age 47.9 years) in a substudy of the ongoing Masked Hypertension Study. VVV of SBP and diastolic blood pressure (DBP) was estimated by the standard deviation (SDvvv) and average real variability (ARVvvv) from 6 study visits over a median of 216 days. ABPM data were used to calculate the day-night SD (SDdn) and the ARV of SBP and DBP over 24 hours (ARV24). For SBP, the mean SDvvv and SDdn were 6.3 (SD=2.5) and 8.8 (SD=1.8) mmHg, respectively, and mean ARVvvv and ARV24 were 7.2 (SD=3.2) and 8.4 (SD=2.1) mmHg, respectively. The Spearman correlation coefficient between SDvvv and SDdn of SBP was rs=0.25 and between ARVvvv and ARV24 was rs=0.17. Participants in the highest quartile of SDdn of SBP were 1.66 (95% CI: 0.93 – 2.75) times more likely to be in the highest quartile of SDvvv of SBP. The observed-to-expected ratio between the highest quartiles of ARVvvv and ARV24 of SBP was 0.89 (95% CI: 0.41 – 1.69). The correlations for SDvvv and SDdn and ARVvvv and ARV24 of DBP were minimal. These data suggest VVV and 24-hour variability are weakly correlated and not interchangeable. PMID:23784506

  5. Norovirus and rotavirus survival in urine collected from a public ecological sanitation system in Ouagadougou, Burkina Faso.

    PubMed

    Makaya, Joseph M; Kaplon, Jérôme; Fremy, Céline; Barro, Nicolas; Aho, Serge; Pothier, Pierre; Belliot, Gaël; Traoré, Alfred S

    2015-03-01

    Urine from urine-diversion toilets (UDTs) is routinely used as fertilizer for urban agriculture in Ouagadougou, Burkina Faso. Because urine from UDTs can be accidentally spoiled by feces, we determined whether virulent enteric viruses could persist in urine that is used for agricultural purposes and pose a threat to human health. Urine samples (N = 60) were first collected from 42 UDTs during the months of January and February 2012 in Ouagadougou and screened negative for the presence of norovirus (NoV) and group A rotavirus (RV). Composite urine from five collection sites was used to determine whether spiked murine norovirus (MNV) and group A bovine rotavirus (boRVA) could remain infectious at 15, 25, and 42 °C over an incubation period of 42 days in phosphate buffered saline (control) and urine. For both viruses, infectivity was determined by plaque assay and the presence of viral genome was evaluated by real-time RT-PCR. A decrease in the infectious titer was observed in composite urines that were experimentally seeded with MNV and boRVA. The decrease in the infectious titer was greater for MNV than for boRVA. Given that MNV was more labile to urine than boRVA was, MNV and boRVA genomes were still detectable after the 42 and 49 days incubation period for MNV and boRVA, respectively. Our data using substitutes of human NoV and RV suggested that there is a virucidal activity of urine against RVs and NoVs, given that the effect was lesser for RV. In spite of disappointing results for boRVA, the use of urine as fertilizer is still promising provided that future safety studies are extended to other enteric viruses.

  6. Urine collection for nicotine and cotinine measurement in studies on nicotine addicts.

    PubMed

    Lequang, N T; Roussel, G; Roche, D; Migueres, M L; Chretien, J; Ekindjian, O G

    1994-02-01

    One of the reasons for the paucity of tabagism exposure data on the consequences of smoking is the difficulty in obtaining urine samples and the fact that the optimal storage conditions remains undetermined. The authors therefore assessed the influence of storage on urinary nicotine and cotinine levels both at room temperature and after freezing. The variations observed were not statistically significant for up to 30 hours at room temperature or for up to 8 days at -25 degrees C. They then studied the excretion of cotinine and nicotine in overnight and 24-h urine specimens collected from 90 non-smokers exposed to tobacco smoke and 40 smokers. The correlation between overnight and 24-h excretion was excellent in the case of cotinine (r = 0.89) and poor for nicotine (r = 0.18), probably because of their respective half-lives. Lastly, the usefulness of referring the urinary cotinine to the urinary creatinine was questioned. The authors conclude that valuable studies should be based on overnight urines samples stored at room temperature for up to 30 hours and then frozen at -25 degrees C until quantification of cotinine expressed in microgram/fraction. PMID:8090564

  7. Reliable Quantification of the Potential for Equations Based on Spot Urine Samples to Estimate Population Salt Intake: Protocol for a Systematic Review and Meta-Analysis

    PubMed Central

    Huang, Liping; Crino, Michelle; Wu, Jason HY; Woodward, Mark; Land, Mary-Anne; McLean, Rachael; Webster, Jacqui; Enkhtungalag, Batsaikhan; Nowson, Caryl A; Elliott, Paul; Cogswell, Mary; Toft, Ulla; Mill, Jose G; Furlanetto, Tania W; Ilich, Jasminka Z; Hong, Yet Hoi; Cohall, Damian; Luzardo, Leonella; Noboa, Oscar; Holm, Ellen; Gerbes, Alexander L; Senousy, Bahaa; Pinar Kara, Sonat; Brewster, Lizzy M; Ueshima, Hirotsugu; Subramanian, Srinivas; Teo, Boon Wee; Allen, Norrina; Choudhury, Sohel Reza; Polonia, Jorge; Yasuda, Yoshinari; Campbell, Norm RC; Neal, Bruce

    2016-01-01

    Background Methods based on spot urine samples (a single sample at one time-point) have been identified as a possible alternative approach to 24-hour urine samples for determining mean population salt intake. Objective The aim of this study is to identify a reliable method for estimating mean population salt intake from spot urine samples. This will be done by comparing the performance of existing equations against one other and against estimates derived from 24-hour urine samples. The effects of factors such as ethnicity, sex, age, body mass index, antihypertensive drug use, health status, and timing of spot urine collection will be explored. The capacity of spot urine samples to measure change in salt intake over time will also be determined. Finally, we aim to develop a novel equation (or equations) that performs better than existing equations to estimate mean population salt intake. Methods A systematic review and meta-analysis of individual participant data will be conducted. A search has been conducted to identify human studies that report salt (or sodium) excretion based upon 24-hour urine samples and spot urine samples. There were no restrictions on language, study sample size, or characteristics of the study population. MEDLINE via OvidSP (1946-present), Premedline via OvidSP, EMBASE, Global Health via OvidSP (1910-present), and the Cochrane Library were searched, and two reviewers identified eligible studies. The authors of these studies will be invited to contribute data according to a standard format. Individual participant records will be compiled and a series of analyses will be completed to: (1) compare existing equations for estimating 24-hour salt intake from spot urine samples with 24-hour urine samples, and assess the degree of bias according to key demographic and clinical characteristics; (2) assess the reliability of using spot urine samples to measure population changes in salt intake overtime; and (3) develop a novel equation that performs

  8. Fluid and electrolyte balance during 24-hour fluid and/or energy restriction.

    PubMed

    James, Lewis J; Shirreffs, Susan M

    2013-12-01

    Weight categorized athletes use a variety of techniques to induce rapid weight loss (RWL) in the days leading up to weigh in. This study examined the fluid and electrolyte balance responses to 24-hr fluid restriction (FR), energy restriction (ER) and fluid and energy restriction (F+ER) compared with a control trial (C), which are commonly used techniques to induce RWL in weight category sports. Twelve subjects (six male, six female) received adequate energy and water (C) intake, adequate energy and restricted water (~10% of C; FR) intake, restricted energy (~25% of C) and adequate water (ER) intake or restricted energy (~25% of C) and restricted (~10% of C) water intake (F+ER) in a randomized counterbalanced order. Subjects visited the laboratory at 0 hr, 12 hr, and 24 hr for blood and urine sample collection. Total body mass loss was 0.33% (C), 1.88% (FR), 1.97% (ER), and 2.44% (F+ER). Plasma volume was reduced at 24 hr during FR, ER, and F+ER, while serum osmolality was increased at 24 hr for FR and F+ER and was greater at 24 hr for FR compared with all other trials. Negative balances of sodium, potassium, and chloride developed during ER and F+ER but not during C and FR. These results demonstrate that 24 hr fluid and/ or energy restriction significantly reduces body mass and plasma volume, but has a disparate effect on serum osmolality, resulting in hypertonic hypohydration during FR and isotonic hypohydration during ER. These findings might be explained by the difference in electrolyte balance between the trials.

  9. Attempt Quit Smoking 24+ Hours Maps and Data of Model-Based Small Area Estimates - Small Area Estimates

    Cancer.gov

    Attempt Quit Smoking 24+ Hours is defined as a person 18 years of age or older who must have reported smoking at least 100 cigarettes in his/her life, and now does not smoke at all but it has been less than 365 days since completely stopped smoking cigarettes, or now smoke everyday or some days but reported that have made attempt of quitting for more than 24 hours in the past 12 months.

  10. Non-24-Hour Sleep-Wake Disorder Revisited - A Case Study.

    PubMed

    Garbazza, Corrado; Bromundt, Vivien; Eckert, Anne; Brunner, Daniel P; Meier, Fides; Hackethal, Sandra; Cajochen, Christian

    2016-01-01

    The human sleep-wake cycle is governed by two major factors: a homeostatic hourglass process (process S), which rises linearly during the day, and a circadian process C, which determines the timing of sleep in a ~24-h rhythm in accordance to the external light-dark (LD) cycle. While both individual processes are fairly well characterized, the exact nature of their interaction remains unclear. The circadian rhythm is generated by the suprachiasmatic nucleus ("master clock") of the anterior hypothalamus, through cell-autonomous feedback loops of DNA transcription and translation. While the phase length (tau) of the cycle is relatively stable and genetically determined, the phase of the clock is reset by external stimuli ("zeitgebers"), the most important being the LD cycle. Misalignments of the internal rhythm with the LD cycle can lead to various somatic complaints and to the development of circadian rhythm sleep disorders (CRSD). Non-24-hour sleep-wake disorders (N24HSWD) is a CRSD affecting up to 50% of totally blind patients and characterized by the inability to maintain a stable entrainment of the typically long circadian rhythm (tau > 24.5 h) to the LD cycle. The disease is rare in sighted individuals and the pathophysiology less well understood. Here, we present the case of a 40-year-old sighted male, who developed a misalignment of the internal clock with the external LD cycle following the treatment for Hodgkin's lymphoma (ABVD regimen, four cycles and AVD regimen, four cycles). A thorough clinical assessment, including actigraphy, melatonin profiles and polysomnography led to the diagnosis of non-24-hour sleep-wake disorders (N24HSWD) with a free-running rhythm of tau = 25.27 h. A therapeutic intervention with bright light therapy (30 min, 10,000 lux) in the morning and melatonin administration (0.5-0.75 mg) in the evening failed to entrain the free-running rhythm, although a longer treatment duration and more intense therapy might have

  11. Non-24-Hour Sleep-Wake Disorder Revisited – A Case Study

    PubMed Central

    Garbazza, Corrado; Bromundt, Vivien; Eckert, Anne; Brunner, Daniel P.; Meier, Fides; Hackethal, Sandra; Cajochen, Christian

    2016-01-01

    The human sleep-wake cycle is governed by two major factors: a homeostatic hourglass process (process S), which rises linearly during the day, and a circadian process C, which determines the timing of sleep in a ~24-h rhythm in accordance to the external light–dark (LD) cycle. While both individual processes are fairly well characterized, the exact nature of their interaction remains unclear. The circadian rhythm is generated by the suprachiasmatic nucleus (“master clock”) of the anterior hypothalamus, through cell-autonomous feedback loops of DNA transcription and translation. While the phase length (tau) of the cycle is relatively stable and genetically determined, the phase of the clock is reset by external stimuli (“zeitgebers”), the most important being the LD cycle. Misalignments of the internal rhythm with the LD cycle can lead to various somatic complaints and to the development of circadian rhythm sleep disorders (CRSD). Non-24-hour sleep-wake disorders (N24HSWD) is a CRSD affecting up to 50% of totally blind patients and characterized by the inability to maintain a stable entrainment of the typically long circadian rhythm (tau > 24.5 h) to the LD cycle. The disease is rare in sighted individuals and the pathophysiology less well understood. Here, we present the case of a 40-year-old sighted male, who developed a misalignment of the internal clock with the external LD cycle following the treatment for Hodgkin’s lymphoma (ABVD regimen, four cycles and AVD regimen, four cycles). A thorough clinical assessment, including actigraphy, melatonin profiles and polysomnography led to the diagnosis of non-24-hour sleep-wake disorders (N24HSWD) with a free-running rhythm of tau = 25.27 h. A therapeutic intervention with bright light therapy (30 min, 10,000 lux) in the morning and melatonin administration (0.5–0.75 mg) in the evening failed to entrain the free-running rhythm, although a longer treatment duration and more intense therapy

  12. What and how much do we eat? 24-hour dietary recall method.

    PubMed

    Salvador Castell, Gemma; Serra-Majem, Lluis; Ribas-Barba, Lourdes

    2015-02-26

    Diet, along with lifestyle factors, is an important determinant of the health status of an individual and of a community. Dietary assessment at the population level provides us with key information on the frequency and distribution of possible inadequate diets and/or nutritional status. It is also useful as input into the elaboration of food and nutrition policies aiming to improve dietary habits and the health status of a community. This article reviews the characteristics, advantages and limitations of the 24-hour dietary recall method (24hDR), which is one of the most widely used tools in nutrition epidemiology to identify food, energy and nutrient intake in national nutrition surveys, cross-sectional studies, clinical trials and cohort studies as well as in the evaluation of individual dietary intake and Total Diet assessment. To reduce the key factors associated with bias, the importance of previously trained interviewers is highlighted, as well as the role of support materials and the contribution of novel technologies.

  13. Severe community-acquired pneumonia: timely management measures in the first 24 hours.

    PubMed

    Phua, Jason; Dean, Nathan C; Guo, Qi; Kuan, Win Sen; Lim, Hui Fang; Lim, Tow Keang

    2016-01-01

    Mortality rates for severe community-acquired pneumonia (CAP) range from 17 to 48 % in published studies.In this review, we searched PubMed for relevant papers published between 1981 and June 2016 and relevant files. We explored how early and aggressive management measures, implemented within 24 hours of recognition of severe CAP and carried out both in the emergency department and in the ICU, decrease mortality in severe CAP.These measures begin with the use of severity assessment tools and the application of care bundles via clinical decision support tools. The bundles include early guideline-concordant antibiotics including macrolides, early haemodynamic support (lactate measurement, intravenous fluids, and vasopressors), and early respiratory support (high-flow nasal cannulae, lung-protective ventilation, prone positioning, and neuromuscular blockade for acute respiratory distress syndrome).While the proposed interventions appear straightforward, multiple barriers to their implementation exist. To successfully decrease mortality for severe CAP, early and close collaboration between emergency medicine and respiratory and critical care medicine teams is required. We propose a workflow incorporating these interventions. PMID:27567896

  14. Sudden cardiac arrest risk stratification based on 24-hour Holter ECG statistics.

    PubMed

    Kasahara, Keisuke; Shiobara, Masahito; Nakamura, Saya; Yamashiro, Koichiro; Yana, Kazuo; Ono, Takuya

    2015-08-01

    This study examined the feasibility of using indices obtained from a long term Holter ECG record for sudden cardiac arrest (SCA) risk stratification. The ndices tested were the QT-RR interval co-variability and the alternans ratio percentile (ARP(θ)) which is defined as the θ(th) percentile of alternans ratios over a 24 hour period. The QT-RR interval co-variabilities are evaluated by the serial correlation coefficient between QT and RR trend sequences (QTRC). Previously reported Kalman filter technique and a simple smoothing spline method for the trend estimation are compared. Parameter θ in the alternans ratio percentile index was optimized to achieve the best classification accuracy. These indices were estimated from 26 cardiovascular outpatients for Holter ECG record. Patients were classified into high and low risk groups according to their clinical diagnosis, and the obtained indices were compared with those of 25 control subjects. A risk stratification using the two indices QTRC and ARP(θ) yielded an average sensitivity of 0.812 and a specificity of 0.925. The sensitivities and specificities of all three categories exceeded 0.8 except for the sensitivity to detect the high-risk patient group. Other short-term ECG parameters may need to be incorporated in order to improve the sensitivity.

  15. 24 Hours in the Life of HIV-1 in a T Cell Line

    PubMed Central

    Mohammadi, Pejman; Desfarges, Sébastien; Bartha, István; Joos, Beda; Zangger, Nadine; Muñoz, Miguel; Günthard, Huldrych F.; Beerenwinkel, Niko; Telenti, Amalio; Ciuffi, Angela

    2013-01-01

    HIV-1 infects CD4+ T cells and completes its replication cycle in approximately 24 hours. We employed repeated measurements in a standardized cell system and rigorous mathematical modeling to characterize the emergence of the viral replication intermediates and their impact on the cellular transcriptional response with high temporal resolution. We observed 7,991 (73%) of the 10,958 expressed genes to be modulated in concordance with key steps of viral replication. Fifty-two percent of the overall variability in the host transcriptome was explained by linear regression on the viral life cycle. This profound perturbation of cellular physiology was investigated in the light of several regulatory mechanisms, including transcription factors, miRNAs, host-pathogen interaction, and proviral integration. Key features were validated in primary CD4+ T cells, and with viral constructs using alternative entry strategies. We propose a model of early massive cellular shutdown and progressive upregulation of the cellular machinery to complete the viral life cycle. PMID:23382686

  16. Age and individual sleep characteristics affect cognitive performance in anesthesiology residents after a 24-hour shift.

    PubMed

    Tadinac, Meri; Sekulić, Ante; Hromatko, Ivana; Mazul-Sunko, Branka; Ivancić, Romina

    2014-03-01

    Previous research has shown that both shift work and sleep deprivation have an adverse influence on various aspects of human cognitive performance. The aim of this study was to explore changes in cognitive functioning and subjective sleepiness of anesthesiology residents after a 24-hour shift. Twenty-six anesthesiology residents completed a set of psychological instruments at the beginning and at the end of the shift, as well as a questionnaire regarding information about the shift, Stanford Sleepiness Scale, and Circadian Type Questionnaire. There was a significant decline in cognitive performance measured by the Auditory Verbal Learning Test after the shift. The effect was stronger in older participants and in those with high scores on rigidity of sleep scale and low scores on the ability to overcome sleepiness scale. There were no differences in the digits forward test (a measure of concentration), while digits backward test (a measure of working memory) even showed an improved performance after the shift. Although participants reported being significantly sleepier after the shift, the subjective sleepiness did not correlate with any of the objective measures of cognitive performance. In conclusion, the performance in short tasks involving concentration and working memory was not impaired, while performance in long-term and monotone tasks declined after sleep deprivation, and the magnitude of this decline depended on the specific individual characteristics of sleep and on age Surprisingly, age seemed to have an important impact on cognitive functions after shift work even in the relatively age-homogeneous population of young anesthesiology residents.

  17. High energy deficit in an ultraendurance athlete in a 24-hour ultracycling race

    PubMed Central

    Rodríguez, Ferran A.; Iglesias, Xavier; Benítez, Adolfo; Marina, Míchel; Padullés, Josep M.; Torrado, Priscila; Vázquez, Jairo; Knechtle, Beat

    2012-01-01

    This case study examined the nutritional behavior and energy balance in an official finisher of a 24-hour ultracycling race. The food and beverages consumed by the cyclist were continuously weighed and recorded to estimate intake of energy, macronutrients, sodium, and caffeine. In addition, during the race, heart rate was continuously monitored. Energy expenditure was assessed using a heart rate–oxygen uptake regression equation obtained previously from a laboratory test. The athlete (39 years, 175.6 cm, 84.2 kg, maximum oxygen uptake, 64 mL/kg/min) cycled during 22 h 22 min, in which he completed 557.3 km with 8760 m of altitude at an average speed of 25.1 km/h. The average heart rate was 131 beats/min. Carbohydrates were the main macronutrient intake (1102 g, 13.1 g/kg); however, intake was below current recommendations. The consumption of protein and fat was 86 g and 91 g, respectively. He ingested 20.7 L (862 mL/h) of fluids, with sport drinks the main fluid used for hydration. Sodium concentration in relation to total fluid intake was 34.0 mmol/L. Caffeine consumption over the race was 231 mg (2.7 mg/kg). During the race, he expended 15,533 kcal. Total energy intake was 5571 kcal, with 4058 (73%) and 1513 (27%) kcal derived from solids and fluids, respectively. The energy balance resulted in an energy deficit of 9915 kcal. PMID:22481841

  18. Obtaining liver tridimensional scaffold through the decellularization of rabbit whole liver in 24 hours

    NASA Astrophysics Data System (ADS)

    Federico, Schliamser; Ayelen, Rinaldi; Romina, Comin; Alba Nelly, Borchert; Adrian, Nari Gustavo; Alicia, Salvatierra Nancy; Mariana Paula, Cid

    2016-04-01

    In the present work, we development a new protocol for liver decellularization in which the hole decellularization was reached over 24 h. Introduction: the availability of transplantable livers is not sufficient to fulfill the current demand for grafts, with the search for therapeutic alternatives having generated different lines of research, one of which is the use of decellularized three-dimensional biological matrices and subsequent cell seeding to obtain a functional organ. Objective: to produce a decellularization protocol from rabbit liver to generate a three-dimensional matrixin which the time period involved didn't pass 24 h. Methods: The decellularization is obtained through the use of water and SDS (0,1-0,3 %), after freezing at -80 degrees, is the best alternative of different physical and/or chemical mechanisms to break down organ cells and leave only the extracellular matriz. After 24 h of retrograde perfusion, a decellularized translucent matrix was generated. To evaluate if the decellularization protocol was successful, with the extracellular matrix being preserved, we carried out histological (light microscopy) and biochemical (DNA quantification) studies. Results: the decellularization process was verified by macroscopic observation of the organ using microscopic observation corroborated the macroscopic results, with the hematoxylin-eosin and Masson staining showing no cells or nuclear material. In addition, the DNA quantification was less than 10% in the decellularized liver compared to control. Finally,the time taken to develop the decellularization protocol was less than 24 hours.

  19. Electrodes for 24 hours pH monitoring--a comparative study.

    PubMed Central

    McLauchlan, G; Rawlings, J M; Lucas, M L; McCloy, R F; Crean, G P; McColl, K E

    1987-01-01

    Three pH electrodes in clinical use were examined--(1) antimony electrode with remote reference electrode (Synectics 0011), (2) glass electrode with remote reference electrode (Microelectrodes Inc. MI 506) and (3) combined glass electrode with integral reference electrode (Radiometer GK2801C). In vitro studies showed that both glass electrodes were similar and superior to the antimony electrode with respect to response time, drift, and sensitivity. The effect of the siting of the reference electrode on the recorded pH was examined in five human volunteers. The pH reading using a remote skin reference electrode was higher by a mean of 0.3 pH units (range 0.0-0.6) in the stomach, lower by 0.65 pH units (0.5-0.8) in the duodenum and lower by 0.3 pH units (0.0-0.6) in the oesophagus than that simultaneously obtained with an intraluminal reference electrode. Buccal reference electrodes gave similar readings to skin. Combined reference and glass pH electrodes are recommended for 24-hour ambulatory pH monitoring. Images Fig. 1 PMID:3666560

  20. Depressive Symptoms and 24-Hour Ambulatory Blood Pressure in Africans: The SABPA Study

    PubMed Central

    Hamer, Mark; Frasure-Smith, Nancy; Lespérance, François; Harvey, Brian H.; Malan, Nico T.; Malan, Leoné

    2012-01-01

    Disturbances in circadian rhythm might play a central role in the neurobiology of depression. We examined the association between depressive symptoms and 24-hour ambulatory BP in a sample of 405 (197 black and 208 Caucasian) urbanized African teachers aged 25 to 60 yrs (mean 44.6 ± 9.6 yrs). Depressive symptoms were assessed using the self-administered 9-item Patient Health Questionnaire (PHQ-9). After adjusting for age, sex, and ethnicity, participants with severe depressive symptoms (PHQ-9 ≥ 15) had higher odds of hypertension defined from ambulatory BP and/or use of antihypertensive medication (odds ratio = 2.19, 95% CI, 1.00–4.90) in comparison to participants with no symptoms. Compared to Caucasians with no depressive symptoms, those with severe symptoms had blunted nocturnal systolic BP drop of 4.7 mmHg (95% CI, −0.5 to 10.0, P = 0.07). In summary, depressive symptoms were associated with the circadian BP profile in black and Caucasian Africans. PMID:22028954

  1. Neonatal family care for 24 hours per day: effects on maternal confidence and breast-feeding.

    PubMed

    Wataker, Heidi; Meberg, Alf; Nestaas, Eirik

    2012-01-01

    In family care (FC) program for neonatal intensive care units (NICUs), parents are encouraged to reside together with their infant for 24 hours a day to actively be involved in the care. The aim of this study was to assess the impact of FC on maternal confidence and breast-feeding. Maternal confidence and rate of breast-feeding were assessed in 31 mothers offered FC that included special family rooms in the NICU, and in 30 mothers from a comparable NICU providing traditional care without such facilities. One week prior to hospital discharge, mothers in the FC group felt better informed regarding nursing issues and had more confidence in interpretation of the infants regarding feeding issues and in caregiving without staff attendance (P < .05). They also reported a higher level of empowerment (P < .05). Three months after discharge, the mothers in the FC group had a higher self-reported skill level for interpretation of the infant's signals and knowledge about breast-feeding (P < .05). Despite similar rate of breast-feeding at discharge, more infants in the FC group were breastfed 3 months after discharge (P < .05). An FC program in the NICU promoted better maternal confidence during the hospital stay and 3 months after discharge compared with traditional care.

  2. Importance of all movement behaviors in a 24 hour period for overall health.

    PubMed

    Chaput, Jean-Philippe; Carson, Valerie; Gray, Casey E; Tremblay, Mark S

    2014-12-01

    Physical inactivity and childhood obesity are well-recognized public health concerns that are associated with a range of adverse health outcomes. Historically, the benefits of physical activity (e.g., moderate-to-vigorous physical activity-MVPA) to overall health have dominated discussions and emerging evidence indicates that a broader, more integrated approach is needed to better understand and address current public health crises. Existing guidelines for children and youth around the world only focus on MVPA, and recently sedentary behavior, despite an accumulating body of evidence showing that light-intensity physical activity (LPA) such as walking can provide important health benefits. Furthermore, there is accumulating support for the importance of adequate sleep and that these behaviors moderate the health impact of each other. Ignoring the other components of the movement continuum (i.e., sleep, sedentary time, LPA) while focusing efforts exclusively on MVPA (accounting for <5% of the time in a 24 h period) limits the potential to optimize the health benefits of movement behaviors. In order to address this limitation, experts in Canada are currently developing the world's first Integrated 24 Hour Movement Behaviour Guidelines for Children and Youth to help advance an integrated healthy active living agenda that has the potential to significantly improve the overall health and well-being of children and youth. PMID:25485978

  3. A 24-HOUR AMBULATORY ECG MONITORING IN ASSESSMENT OF QT INTERVAL DURATION AND DISPERSION IN ROWERS WITH PHYSIOLOGICAL MYOCARDIAL HYPERTROPHY

    PubMed Central

    Kim, Z.F.; Bilalova, R.R.; Tsibulkin, N.A.; Almetova, R.R.; Mudarisova, R.R.; Ahmetov, I.I.

    2013-01-01

    Myocardial hypertrophy (MH) due to cardiac pathology is characterized by an increase in QT interval duration and dispersion, while the findings for exercise-induced myocardial hypertrophy are contradictory. The majority of published research findings have not explored this relationship, but there have only been a few conducted studies using 24-hour ECG monitoring. The aim of the study was to determine the QT interval duration and dispersion in short-term and 24-hour ECG in endurance athletes with myocardial hypertrophy and without it. Methods: A total of 26 well-trained rowers underwent a resting 12-lead ECG, 24-hour ECG monitoring and echocardiography. Results: Athletes with MH (n = 7) at rest did not show any increase in QTc interval duration and dispersion, or mean and maximal QTc duration in Holter monitoring compared to athletes without MH (n = 19). Left ventricular mass was not significantly correlated with any QTc characteristics. Furthermore, athletes with MH had significantly longer mean QT (P = 0.01) and maximal QT (P = 0.018) intervals in Holter monitoring and higher 24-hour heart rate variability indexes due to stronger vagal effects. Conclusions: The present study demonstrated that athlete's heart syndrome with myocardial hypertrophy as a benign phenomenon does not lead to an increase in QT interval duration, or increases in maximal and mean duration in a 24-hour ECG. An increase in QT interval duration in athletes may have an autonomic nature. PMID:24744494

  4. Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring

    PubMed Central

    Barrett, Paddy M.; Komatireddy, Ravi; Haaser, Sharon; Topol, Sarah; Sheard, Judith; Encinas, Jackie; Fought, Angela J.; Topol, Eric J.

    2013-01-01

    BACKGROUND Cardiac arrhythmias are remarkably common and routinely go undiagnosed because they are often transient and asymptomatic. Effective diagnosis and treatment can substantially reduce the morbidity and mortality associated with cardiac arrhythmias. The Zio Patch (iRhythm Technologies, Inc, San Francisco, Calif) is a novel, single-lead electrocardiographic (ECG), lightweight, Food and Drug Administration–cleared, continuously recording ambulatory adhesive patch monitor suitable for detecting cardiac arrhythmias in patients referred for ambulatory ECG monitoring. METHODS A total of 146 patients referred for evaluation of cardiac arrhythmia underwent simultaneous ambulatory ECG recording with a conventional 24-hour Holter monitor and a 14-day adhesive patch monitor. The primary outcome of the study was to compare the detection arrhythmia events over total wear time for both devices. Arrhythmia events were defined as detection of any 1 of 6 arrhythmias, including supraventricular tachycardia, atrial fibrillation/flutter, pause greater than 3 seconds, atrioventricular block, ventricular tachycardia, or polymorphic ventricular tachycardia/ventricular fibrillation. McNemar’s tests were used to compare the matched pairs of data from the Holter and the adhesive patch monitor. RESULTS Over the total wear time of both devices, the adhesive patch monitor detected 96 arrhythmia events compared with 61 arrhythmia events by the Holter monitor (P < .001). CONCLUSIONS Over the total wear time of both devices, the adhesive patch monitor detected more events than the Holter monitor. Prolonged duration monitoring for detection of arrhythmia events using single-lead, less-obtrusive, adhesive-patch monitoring platforms could replace conventional Holter monitoring in patients referred for ambulatory ECG monitoring. PMID:24384108

  5. Sleep-Disordered Breathing and 24-Hour Blood Pressure Pattern Among Older Adults

    PubMed Central

    White, William B.; Kutner, Michael; Ouslander, Joseph G.; Bliwise, Donald L.

    2009-01-01

    Background To examine the association between sleep-disordered breathing (SDB) and 24-hour blood pressure (BP) pattern among community-dwelling older adults. Methods A convenience sample of 70 community-dwelling older adults, recruited from senior housing, community centers, and learning centers, were admitted to General Clinical Research Center, Emory University Hospital, Atlanta, Ga. Information regarding demographic and clinical history was obtained using questionnaires. Twenty-four–hour BP monitoring in supine position was performed using Spacelabs model 20207. Breathing during sleep was monitored with the use of a modified sleep recording system (Embletta, PDS), which monitors nasal and oral airflow, chest and abdominal movements, and pulse oximetry. Night time–daytime (night-day) BP ratio (average night-time BP divided by daytime BP) was calculated both for systolic and diastolic BPs. Results Sixty-nine participants, mean age 74.9 ± 6.4 years (41 [57%] women), completed the study. The mean apnea-hypopnea index (AHI) was 13 ± 13 per hour of sleep, and 20 participants (29%) had AHI ≥15 per hour of sleep, indicating moderate to severe SDB. Moderate to severe SDB (AHI ≥15 per hour of sleep) was significantly associated with nocturnal hypertension, whereas there was no statistically significant difference in wake-time BP between those with and without moderate to severe SDB. Stepwise multiple regressions showed that AHI independently predicted increased night-day systolic and night-day diastolic BP ratio, even after controlling for nocturia frequency. Conclusions The results indicate increased BP load associated with increased AHI in this group of older adults. This increased BP load may contribute to increased hypertension-related morbidity and disease burden. PMID:19196901

  6. Methodology for adding glycemic index and glycemic load values to 24-hour dietary recall database

    PubMed Central

    Olendzki, Barbara C.; Ma, Yunsheng; Culver, Annie L.; Ockene, Ira S.; Griffith, Jennifer A.; Hafner, Andrea R.; Hebert, James R.

    2006-01-01

    Objectives We describe a method of adding the glycemic index (GI) and glycemic load (GL) values to the nutrient database of the 24-hour dietary recall interview (24HR), a widely used dietary assessment. We also calculated daily GI and GL values from the 24HR. Methods Subjects were 641 healthy adults from central Massachusetts who completed 9067 24HRs. The 24HR-derived food data were matched to the International Table of Glycemic Index and Glycemic Load Values. The GI values for specific foods not in the table were estimated against similar foods according to physical and chemical factors that determine GI. Mixed foods were disaggregated into individual ingredients. Results Of 1261 carbohydrate-containing foods in the database, GI values of 602 foods were obtained from a direct match (47.7%), accounting for 22.36% of dietary carbohydrate. GI values from 656 foods (52.1%) were estimated, contributing to 77.64% of dietary carbohydrate. The GI values from three unknown foods (0.2%) could not be assigned. The average daily GI was 84 (SD 5.1, white bread as referent) and the average GL was 196 (SD 63). Conclusion Using this methodology for adding GI and GL values to nutrient databases, it is possible to assess associations between GI and/or GL and body weight and chronic disease outcomes (diabetes, cancer, heart disease). This method can be used in clinical and survey research settings where 24HRs are a practical means for assessing diet. The implications for using this methodology compel a broader evaluation of diet with disease outcomes. PMID:17029903

  7. Folate Catabolites in Spot Urine as Non-Invasive Biomarkers of Folate Status during Habitual Intake and Folic Acid Supplementation

    PubMed Central

    Niesser, Mareile; Demmelmair, Hans; Weith, Thea; Moretti, Diego; Rauh-Pfeiffer, Astrid; van Lipzig, Marola; Vaes, Wouter; Koletzko, Berthold; Peissner, Wolfgang

    2013-01-01

    Background Folate status, as reflected by red blood cell (RCF) and plasma folates (PF), is related to health and disease risk. Folate degradation products para-aminobenzoylglutamate (pABG) and para-acetamidobenzoylglutamate (apABG) in 24 hour urine have recently been shown to correlate with blood folate. Aim Since blood sampling and collection of 24 hour urine are cumbersome, we investigated whether the determination of urinary folate catabolites in fasted spot urine is a suitable non-invasive biomarker for folate status in subjects before and during folic acid supplementation. Study Design and Methods Immediate effects of oral folic acid bolus intake on urinary folate catabolites were assessed in a short-term pre-study. In the main study we included 53 healthy men. Of these, 29 were selected for a 12 week folic acid supplementation (400 µg). Blood, 24 hour and spot urine were collected at baseline and after 6 and 12 weeks and PF, RCF, urinary apABG and pABG were determined. Results Intake of a 400 µg folic acid bolus resulted in immediate increase of urinary catabolites. In the main study pABG and apABG concentrations in spot urine correlated well with their excretion in 24 hour urine. In healthy men consuming habitual diet, pABG showed closer correlation with PF (rs = 0.676) and RCF (rs = 0.649) than apABG (rs = 0.264, ns and 0.543). Supplementation led to significantly increased folate in plasma and red cells as well as elevated urinary folate catabolites, while only pABG correlated significantly with PF (rs = 0.574) after 12 weeks. Conclusion Quantification of folate catabolites in fasted spot urine seems suitable as a non-invasive alternative to blood or 24 hour urine analysis for evaluation of folate status in populations consuming habitual diet. In non-steady-state conditions (folic acid supplementation) correlations between folate marker (RCF, PF, urinary catabolites) decrease due to differing kinetics. PMID:23457526

  8. Hydrogen ion secretion by the collecting duct as a determinant of the urine to blood PCO2 gradient in alkaline urine

    SciTech Connect

    DuBose, T.D. Jr.

    1982-01-01

    Several theories have been advanced to explain the elevation in urinary PCO/sub 2/ during bicarbonate loading and include: (a) H+ secretion, (b) countercurrent system for CO/sub 2/, (c) the ampholyte properties of bicarbonate, and (d) mixing of urine of disparate bicarbonate and butter concentrations. In this study microelectrodes were used to measure in situ and equilibrium pH (pHis and pHeq) and PCO/sub 2/ in control and bicarbonate loaded rats before and after infusion of carbonic anhydrase. The disequilibrium pH method (pHdq . pHis - pHeq) was used to demonstrate H+ secretion. Control rats excreting an acid urine (pH . 6.04 +/- 0.06) failed to display a significant disequilibrium pH at the base (BCD), or tip (TCD) of the papillary collecting duct. Urine pH (7.54 +/- 0.12), and urine to blood (U-B) PCO/sub 2/ increased significantly during NaHCO/sub 3/ loading while PCO/sub 2/ at the BCD and TCD also increased (95 +/- 4 and 122 +/- 4). Furthermore, an acid disequilibrium pH was present at both the BCD and TCD (-0.42 +/- 0.04 and -0.36 +/- 0.03) and was obliterated by carbonic anhydrase. Comparison of the PCO/sub 2/ in the BCD or TCD with the adjacent vasa recta revealed similar values (r . 0.97). It is concluded that H+ secretion by the collecting duct into bicarbonate containing fluid with delayed dehydration of H/sub 2/CO/sub 3/, is the most likely determinant of the U-B PCO/sub 2/ in alkaline urine. Similar values for PCO/sub 2/ in the collecting duct and the adjacent vasa recta suggests trapping of CO/sub 2/ in the medullary countercurrent system. The rise in PCO/sub 2/ occurs both along the collecting duct and after exit from the papilla.

  9. Executive Functions are not Affected by 24 Hours of Sleep Deprivation: A Color-Word Stroop Task Study

    PubMed Central

    Dixit, Abhinav; Mittal, Tushar

    2015-01-01

    Background: Sleep is an important factor affecting cognitive performance. Sleep deprivation results in fatigue, lack of concentration, confusion and sleepiness along with anxiety, depression and irritability. Sleep deprivation can have serious consequences in professions like armed forces and medicine where quick decisions and actions need to be taken. Color-Word Stroop task is one of the reliable tests to assess attention and it analyzes the processing of information in two dimensions i.e., reading of words and naming of colour. The evidence regarding the effect of sleep deprivation on Stroop interference is conflicting. The present study evaluated the effect of 24 hours of sleep deprivation on reaction time and interference in Stroop task. Materials and Methods: The present study was done on 30 healthy male medical student volunteers in the age group of 18-25 years after taking their consent and clearance from Institute Ethics Committee. Recordings of Stroop task were at three times: baseline (between 7-9 am), after 12 hours (7-9 pm) and after 24 hours (7-9 am, next day). The subjects were allowed to perform normal daily activities. Results: The study revealed a significant increase in reaction time after 24 hours of sleep deprivation in comparison to baseline and after 12 hours of sleep deprivation. There was no significant change in interference and facilitation after sleep deprivation in comparison to baseline. The number of errors also did not show any significant change after sleep deprivation. Conclusion: The study indicated that there was slowing of responses without change in executive functions after 24 hours of sleep deprivation. It is probable that 24 hours of sleep deprivation does not bring about change in areas of brain affecting executive functions in healthy individuals who have normal sleep cycle. The present study indicated that in professions like armed forces and medicine working 24 hours at a stretch can lead to decrease in motor responses

  10. Sex differences in 24-hour ultra-marathon performance - A retrospective data analysis from 1977 to 2012

    PubMed Central

    Peter, Laura; Rüst, Christoph Alexander; Knechtle, Beat; Rosemann, Thomas; Lepers, Romuald

    2014-01-01

    OBJECTIVES: This study examined the changes in running performance and the sex differences between women and men in 24-hour ultra-marathons held worldwide from 1977 to 2012. METHOD: Changes in running speed and ages of the fastest 24-hour ultra-marathoners were determined using single- and multi-level regression analyses. RESULTS: From 1977 to 2012, the sex differences in 24-hour ultra-marathon performance were 4.6±0.5% for all women and men, 13.3% for the annual fastest finishers, 12.9±0.8% for the top 10 and 12.2±0.4% for the top 100 finishers. Over time, the sex differences decreased for the annual fastest finishers to 17%, for the annual 10 fastest finishers to 11.3±2.2% and for the annual 100 fastest finishers to 14.2±1.8%. For the annual fastest men, the age of peak running speed increased from 23 years (1977) to 53 years (2012). For the annual 10 and 100 fastest men, the ages of peak running speed were unchanged at 40.9±2.5 and 44.4±1.1 years, respectively. For women, the ages of the annual fastest, the annual 10 fastest and the annual 100 fastest remained unchanged at 43.0±6.1, 43.2±2.6 and 43.8±0.8 years, respectively. CONCLUSION: The gap between the annual top, annual top 10 and annual top 100 female and male 24-hour ultra-marathoners decreased over the last 35 years; however, it seems unlikely that women will outrun men in 24-hour ultra-marathons in the near future. The fastest 24-hour ultra-marathoners worldwide achieved their peak performance at the age of master athletes (>35 years). PMID:24473558

  11. Clean catch urine sample

    MedlinePlus

    Urine culture - clean catch; Urinalysis - clean catch; Clean catch urine specimen; Urine collection - clean catch ... lips" (labia). You may be given a special clean-catch kit that contains sterile wipes. Sit on ...

  12. Plasma Levels of Middle Molecules to Estimate Residual Kidney Function in Haemodialysis without Urine Collection

    PubMed Central

    Vilar, Enric; Boltiador, Capella; Wong, Jonathan; Viljoen, Adie; Machado, Ashwini; Uthayakumar, Arani; Farrington, Ken

    2015-01-01

    Background Residual Kidney Function (RKF) is associated with survival benefits in haemodialysis (HD) but is difficult to measure without urine collection. Middle molecules such as Cystatin C and β2-microglobulin accumulate in renal disease and plasma levels have been used to estimate kidney function early in this condition. We investigated their use to estimate RKF in patients on HD. Design Cystatin C, β2-microglobulin, urea and creatinine levels were studied in patients on incremental high-flux HD or hemodiafiltration(HDF). Over sequential HD sessions, blood was sampled pre- and post-session 1 and pre-session 2, for estimation of these parameters. Urine was collected during the whole interdialytic interval, for estimation of residual GFR (GFRResidual = mean of urea and creatinine clearance). The relationships of plasma Cystatin C and β2-microglobulin levels to GFRResidual and urea clearance were determined. Results Of the 341 patients studied, 64% had urine output>100ml/day, 32.6% were on high-flux HD and 67.4% on HDF. Parameters most closely correlated with GFRResidual were 1/β2-micoglobulin (r2 0.67) and 1/Cystatin C (r2 0.50). Both these relationships were weaker at low GFRResidual. The best regression model for GFRResidual, explaining 67% of the variation, was: GFRResidual=160.3⋅(1β2m)−4.2 Where β2m is the pre-dialysis β2 microglobulin concentration (mg/L). This model was validated in a separate cohort of 50 patients using Bland-Altman analysis. Areas under the curve in Receiver Operating Characteristic analysis aimed at identifying subjects with urea clearance≥2ml/min/1.73m2 was 0.91 for β2-microglobulin and 0.86 for Cystatin C. A plasma β2-microglobulin cut-off of ≤19.2mg/L allowed identification of patients with urea clearance ≥2ml/min/1.73m2 with 90% specificity and 65% sensitivity. Conclusion Plasma pre-dialysis β2-microglobulin levels can provide estimates of RKF which may have clinical utility and appear superior to cystatin C. Use

  13. Circadian (about 24-hour) variation in malondialdehyde content and catalase activity of mouse erythrocytes.

    PubMed

    Sani, Mamane; Sebai, Hichem; Ghanem-Boughanmi, Néziha; Boughattas, Naceur A; Ben-Attia, Mossadok

    2015-01-01

    Lipid peroxidation is a part of normal metabolism that may cause biological molecule damage leading to the formation of several specific metabolites that include aldehydes of variable chains, such as malondialdehyde (MDA). These biological effects are controlled in vivo by a wide spectrum of enzymatic and non-enzymatic defense mechanisms among which catalase (CAT) is considered as an important regulator of oxidative stress. The present study aimed to investigate the possible relationship between the temporal patterns of the formation of MDA and the activity of CAT in the erythrocytes of mice. Twenty-four-hour studies were performed on male Swiss albino mice, 12 weeks old, synchronized to a 12:12 light: dark cycle for 3 weeks. Different and comparable groups of animals (n = 10) were sacrificed at an interval of 4 hours (1, 5, 9, 13, 17, and 21 hours after light onset (HALO)). The levels of erythrocyte MDA concentration and CAT activity both significantly (analysis of variance: F = 6.4, P < 0.002) varied according to the time of sampling under non-stressed conditions. The characteristics of the waveform describing the temporal patterns differed between the two studied variables, e.g. MDA content showing one peak (≅21 HALO) and CAT activity showing three peaks (≅9, 17, and 21 HALO). Cosinor analysis revealed a significant (adjusted Cosinor: P ≤ 0.018) circadian (τ ≅ 24 hours) rhythm in MDA level and no statistically significant rhythmicity in CAT activity. The differences and the absence of correlation between the curve patterns of erythrocyte MDA content and CAT activity under physiological conditions are hypothesized to explain that variation in lipid peroxidation may depend on several factors. Moreover, the identification of peak/trough levels of MDA accumulation in erythrocytes may reflect the degree of oxidative stress in these blood cells. In addition, the observed significant time-of-day effect suggests that, in both clinical and scientific

  14. Characterisation of sleep in intensive care using 24-hour polysomnography: an observational study

    PubMed Central

    2013-01-01

    Introduction Many intensive care patients experience sleep disruption potentially related to noise, light and treatment interventions. The purpose of this study was to characterise, in terms of quantity and quality, the sleep of intensive care patients, taking into account the impact of environmental factors. Methods This observational study was conducted in the adult ICU of a tertiary referral hospital in Australia, enrolling 57 patients. Polysomnography (PSG) was performed over a 24-hour period to assess the quantity (total sleep time: hh:mm) and quality (percentage per stage, duration of sleep episode) of patients' sleep while in ICU. Rechtschaffen and Kales criteria were used to categorise sleep. Interrater checks were performed. Sound pressure and illuminance levels and care events were simultaneously recorded. Patients reported on their sleep quality in ICU using the Richards Campbell Sleep Questionnaire and the Sleep in Intensive Care Questionnaire. Data were summarised using frequencies and proportions or measures of central tendency and dispersion as appropriate and Cohen's Kappa statistic was used for interrater reliability of the sleep data analysis. Results Patients' median total sleep time was 05:00 (IQR: 02:52 to 07:14). The majority of sleep was stage 1 and 2 (medians: 19 and 73%) with scant slow wave and REM sleep. The median duration of sleep without waking was 00:03. Sound levels were high (mean Leq 53.95 dB(A) during the day and 50.20 dB(A) at night) and illuminance levels were appropriate at night (median <2 lux) but low during the day (median: 74.20 lux). There was a median 1.7 care events/h. Patients' mean self-reported sleep quality was poor. Interrater reliability of sleep staging was highest for slow wave sleep and lowest for stage 1 sleep. Conclusions The quantity and quality of sleep in intensive care patients are poor and may be related to noise, critical illness itself and treatment events that disturb sleep. The study highlights the

  15. Analysis of 24-Hour Ambulatory Blood Pressure Monitoring in Children With Obstructive Sleep Apnea

    PubMed Central

    Kang, Kun-Tai; Chiu, Shuenn-Nan; Weng, Wen-Chin; Lee, Pei-Lin; Hsu, Wei-Chung

    2015-01-01

    Abstract In the present study, we aimed to verify associations between ambulatory blood pressure (ABP) and pediatric obstructive sleep apnea (OSA) in a hospital-based population. This was a cross-sectional observational study on children aged 4 to 16 years with OSA-related symptoms from a tertiary referral medical center. All children received overnight polysomnography and 24-hour recording of ABP. Severity of the disease was classified as primary snoring (apnea-hypopnea index, AHI <1), mild OSA (AHI 1–5), and moderate-to-severe OSA (AHI >5). For 195 children enrolled in this study (mean age, 7.8 ± 3.4 years; 69% boy), ABP increased as severity of OSA increased. During daytime, children with moderate-to-severe OSA had significantly higher systolic blood pressure (BP) (117.0 ± 12.7 vs 110.5 ± 9.3 mmHg), mean arterial pressure (MAP) (85.6 ± 8.1 vs 81.6 ± 6.8 mmHg), and diastolic BP load (12.0 ± 9.6 vs 8.4 ± 10.9 mmHg) compared with children with primary snoring. During nighttime, children with moderate-to-severe OSA had significantly higher systolic BP (108.6 ± 15.0 vs 100.0 ± 9.4 mmHg), MAP (75.9 ± 9.6 vs 71.1 ± 7.0 mmHg), systolic BP load (44.0 ± 32.6 vs 26.8 ± 24.5 mmHg), systolic BP index (0.5 ± 13.1 vs −6.8 ± 8.5 mmHg), and higher prevalence of systolic hypertension (47.6% vs 14.7 %) compared with children with primary snoring. Multiple linear regression analyses revealed an independent association between AHI and nighttime systolic BP and MAP after adjusting for adiposity variables. This large hospital-based study showed that children with moderate-to-severe OSA had a higher ABP compared with children who were primary snorers. As elevated BP in childhood predicts future cardiovascular risks, children with severe OSA should be treated properly to prevent further adverse cardiovascular outcomes. PMID:26448004

  16. 49 CFR 40.63 - What steps does the collector take in the collection process before the employee provides a urine...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... collection process before the employee provides a urine specimen? 40.63 Section 40.63 Transportation Office... PROGRAMS Urine Specimen Collections § 40.63 What steps does the collector take in the collection process... water or other materials that could be used to adulterate or dilute a specimen. (c) Select, or allow...

  17. Quantitation of products from riboflavin in rat urine

    SciTech Connect

    Chastain, J.L.; McCormick, D.B.

    1986-03-05

    When (2-/sup 14/C) riboflavin is injected i.p. into rats, the excreted vitamin in urine and feces has been shown to be the intact vitamin with trace amounts of lumichrome and lumiflavin. Recent findings with /sup 14/C-riboflavin fed to rats indicated higher levels of riboflavin catabolites in urine, e.g., 7- and 8-carboxylumichromes. The authors have determined catabolites in urine from male rats fed 0, 2, and 6 ..mu..g riboflavin/g diet/day for six weeks. Two rats from each group were placed weekly in metabolic cages, and urine was collected for 24 hours. On the fourth week, a third animal from each group received an i.p. injection of /sup 14/C-riboflavin and the urine was collected for 48 hours. Urine samples were extracted with phenol for flavin components and with chloroform for derivatives of lumichrome and lumiflavin. Riboflavin was the predominant flavin excreted by all diet groups with trace amounts of coenzymes and 7- and 8-hydroxymethylriboflavin. Riboflavin accounted for 85% of all the radioactivity recovered from the deficient and sufficient rats and 90% in rats fed excess. Lumichrome-type compounds including carboxylumichromes accounted for only a few % of recovered radioactivity. Thus, these components are primarily a product of intestinal microfloral degradation rather than significant tissue catabolites of riboflavin.

  18. Value of 24-hour Delayed Film of Barium Enema for Evaluation of Colon Transit Function in Young Children with Constipation

    PubMed Central

    Yoo, Ha Yeong; Son, Jae Sung; Park, Hye Won; Kwak, Byung Ok; Kim, Hyeong Su; Bae, Sun Hwan

    2016-01-01

    Background/Aims A colon transit time test using radio-opaque markers (CTTRM) is considered the gold standard for evaluating colon transit function. A 24-hour delayed film of barium enema (BE) has been used as a supplementary method in structural evaluations. The aim of this study was to evaluate the utility of a 24-hour delayed BE film for assessing colon transit function in young children with constipation. Methods In total, 93 children with constipation who performed both single-contrast BE and CTTRM were enrolled in this study. Of these, the data from 70 children were analyzed (males 33, females 37; mean age [range], 5.63 ± 2.94 [2–14] years). The basic principle of the study is “velocity = distance/time”. Time values were identified in both studies, and the colon length and distance of barium movement were measured on the 24-hour delayed BE film. Thus, colon transit velocity values could be calculated using both methods. The correlation between colon transit velocity using a 24-hour delayed BE film versus CTTRM was analyzed statistically. Results Median value (interquartile range) of colon transit velocity using CTTRM was 1.57 (1.07–2.89) cm/hr, and that using BE of that was 1.58 (0.94–2.07) cm/hr. The Spearman correlation coefficient was 0.438 (P < 0.001) for the overall group. The correlation was strongest in children younger than 4 years (r = 0.537, P = 0.032). Conclusions Although the correlation between BE and CTTRM was not very strong, the 24-hour delayed BE film could provide broad information about colon transit function in young children, especially those under 4 years who usually cannot undergo CTTRM. PMID:26979249

  19. Microleakage of Two Self-Adhesive Cements in the Enamel and Dentin After 24 Hours and Two Months

    PubMed Central

    Jaberi Ansari, Zahra; Kalantar Motamedi, Mojdeh

    2014-01-01

    Objective: Microleakage is a main cause of restorative treatment failure. In this study, we compared occlusal and cervical microleakage of two self-adhesive cements after 24 hours and two months. Materials and Methods: In this in-vitro experimental study, class II inlay cavities were prepared on 60 sound human third molars. Composite inlays were fabricated with Z100 composite resin. The teeth were randomly assigned to six groups. RelyX-Arc (control), RelyX-Unicem and Maxcem were used for the first three groups and specimens were stored in distilled water at 37°C for 24 hours. The same cements were used for the remaining three groups, but the specimens were stored for 2 months. The teeth were subjected to 500 thermal cycles (5°C and 55°C) and immersed in 0.5% basic fuchsin for 24 hours and then sectioned mesiodistally and dye penetration was evaluated in a class II cavity with occlusal and cervical margins using X20 magnification stereomicroscope. Data were analyzed using Kruskal Wallis and Mann-Whitney U tests. Results: After 24 hours, cements had significant differences only in cervical margin microleakage (P=0.0001) and microleakage of RelyX-Unicem and Maxcem was significantly more than that of RelyX-Arc (both P=0.0001). Cervical microleakage in RelyX-Unicem and Maxcem was greater than occlusal (P=0.0001 and P=0.001, respectively). Microleakage was not significantly different between the occlusal and cervical margins after 2 months. Conclusion: Cervical microleakage was greater than occlusal in RelyX-Unicem and Maxcem after 24h. The greatest microleakage was reported for the cervical margin of RelyX-Unicem after 24 hours. PMID:25584053

  20. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... is a single-toilet room, having a full-length privacy door, within which urination can occur. (1) No... include is a multistall restroom. (1) Such a site must provide substantial visual privacy (e.g., a toilet... agent in all toilets or secure the toilets to prevent access; or (ii) Conduct all collections in...

  1. 49 CFR 40.41 - Where does a urine collection for a DOT drug test take place?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... is a single-toilet room, having a full-length privacy door, within which urination can occur. (1) No... include is a multistall restroom. (1) Such a site must provide substantial visual privacy (e.g., a toilet... agent in all toilets or secure the toilets to prevent access; or (ii) Conduct all collections in...

  2. Crystallisation properties in stone forming and normal subjects' urine diluted using a standardised procedure to match the composition of urine in the distal part of the distal tubule and the middle part of the collecting duct.

    PubMed

    Tiselius, H G; Hallin, A; Lindbäck, B

    2001-04-01

    Using a standardised procedure, we assessed the crystallisation properties of calcium phosphate in urine with a composition matching that in the distal part of the distal tubules (DTd) and of calcium oxalate in urine with a composition matching that in the mid-collecting duct (CDm). We used 8-h urine samples collected between 2200 h and 0600 h with sodium azide as preservative. Urine from ten patients with recurrent CaOx stone formation and from ten normal subjects was used for the measurements. The DTd and CDm samples were obtained by diluting the voided 8-h urine to 3000 ml and 1750 ml per 1.73 m2 body surface area, respectively. The nucleation was studied in DTd urine following supersaturation with CaP. The crystal size distribution was assessed with a Coulter counter both following supersaturation of DTd urine with CaP and of CDm urine with CaOx. The crystallisation of CaP in DTd urine as well as that of CaOx in CDm urine, in the presence of CaP crystals that had been precipitated in DTd urine, was measured with the isotope technique. The inhibition of CaOx and brushite crystal aggregation in standardised diluted aliquots of DTd and CDm urine was assessed spectrophotometrically as the rate of sedimentation. There was a slightly increased sedimentation rate and a lower initial absorbance in DTd urine from stone formers supersaturated with CaP. Although these findings might reflect a state of increased crystal aggregation in stone formers' urine, this could not be confirmed by crystal size measurements in the Coulter counter. The inhibition of brushite crystal aggregation in DTd urine was significantly in stone formers' urine than in normal subjects' urine (P < 0.001). Moreover, all inhibition values in DTd samples from stone formers were negative, suggesting a promoter effect on crystal aggregation. The inhibition of CaOx crystal aggregation in CDm urine also was significantly higher in CDm urine from normal subjects than in CDm urine from stone formers (P < 0

  3. Non-invasive urine collection in the female southern hairy-nosed wombat (Lasiorhinus latifrons) with the aid of classical conditioning.

    PubMed

    Swinbourne, Alyce M; Janssen, Tina; Phillips, Clive J C; Johnston, Stephen D

    2015-01-01

    We propose that regular urine samples can be used to monitor and characterize the reproductive cycle of the wombat, but this approach has never before been attempted in a marsupial. We conducted a three stage conditioning process for non-invasive urine collection in captive female wombats, which included (1) initial habituation and observation of urination patterns; (2) classical association of a stimulus with urination and (3) urine collection with the classically-conditioned stimulus. Four of the five female wombats selected for this trial were successfully conditioned for urine collection. During stage 2, the animals urinated in response to tactile stimulation 96 times from 208 attempts (46%). In stage 3, urine was successfully collected 399 times from 485 attempts (82%), with the majority of samples being collected in the morning (280/388). Hand-raised females that were previously conditioned for toileting purposes as pouch young responded more rapidly to the stimulus than juvenile females with no prior conditioning. This study is the first description of a successful method of urine collection by classical conditioning in a marsupial. PMID:25201777

  4. Non-invasive urine collection in the female southern hairy-nosed wombat (Lasiorhinus latifrons) with the aid of classical conditioning.

    PubMed

    Swinbourne, Alyce M; Janssen, Tina; Phillips, Clive J C; Johnston, Stephen D

    2015-01-01

    We propose that regular urine samples can be used to monitor and characterize the reproductive cycle of the wombat, but this approach has never before been attempted in a marsupial. We conducted a three stage conditioning process for non-invasive urine collection in captive female wombats, which included (1) initial habituation and observation of urination patterns; (2) classical association of a stimulus with urination and (3) urine collection with the classically-conditioned stimulus. Four of the five female wombats selected for this trial were successfully conditioned for urine collection. During stage 2, the animals urinated in response to tactile stimulation 96 times from 208 attempts (46%). In stage 3, urine was successfully collected 399 times from 485 attempts (82%), with the majority of samples being collected in the morning (280/388). Hand-raised females that were previously conditioned for toileting purposes as pouch young responded more rapidly to the stimulus than juvenile females with no prior conditioning. This study is the first description of a successful method of urine collection by classical conditioning in a marsupial.

  5. Comparison of Uriswab to alternative methods for urine culture collection and transport: confirmation of standard culture methodology for investigation of urinary tract infections.

    PubMed

    Rennie, Robert P; Turnbull, Lee-Ann; Gauchier-Pitts, Kaylee; Bennett, Tracy; Dyrland, Debbie; Blonski, Susan

    2016-08-01

    The ability to isolate and identify causative agents of urinary tract infections relies primarily on the quality of the urine sample that is submitted to the microbiology. The most important factors are the method of collection, the maintenance of viability of the potential pathogens during transport, and standardization of the culturing of the urine sample. This report is a composite of several investigations comparing collection and transport on urine culture paddles, with a preservative urine sponge (Uriswab), and a comparison of Uriswab with the BD preservative transport tube as methods of preservation of urinary pathogens. Primary studies showed that Uriswab maintained significantly more urinary pathogens than the urine culture paddle with fewer mixed or contaminated cultures. The two preservative transport systems were comparable for maintenance of viability of the pathogens, but there were fewer mixed cultures when samples were collected with Uriswab. This study confirms the importance of a standard volume of 1 μL of urine for culture. PMID:27233427

  6. HOW RELIABLE IS 24 HOUR SERUM LITHIUM LEVEL AFTER A TEST DOSE OF LITHIUM IN PREDICTING OPTIMAL LITHIUM DOSE?

    PubMed Central

    Kuruvilla, K.; Shaji, K.S.

    1989-01-01

    SUMMARY 57% of a group of 35 patients treated with Lithium Carbonate at dosages predicted by the nomogram suggested by Cooper et al (1973) failed to reach therapeutic levels of serum lithium. This finding casts serious doubts on the usefulness of the claim by Cooper et al (1973 & 1976) that 24 hour serum lithium level after a test dose of 600 mg. lithium can predict the daily lithium dose. PMID:21927360

  7. Increased energy density of the home-delivered lunch meal improves 24-hour nutrient intakes in older adults.

    PubMed

    Silver, Heidi J; Dietrich, Mary S; Castellanos, Victoria H

    2008-12-01

    As food intake declines with aging, older adults develop energy and nutrient inadequacies. It is important to design practical approaches to combat insufficient dietary intakes to decrease risk for acute and chronic diseases, illness, and injury. Manipulating the energy density of meals has improved energy intakes in institutional settings, but the effects on community-residing older adults who are at nutrition risk have not been investigated. The aim of this study was to determine whether enhancing the energy density of food items regularly served in a home-delivered meals program would increase lunch and 24-hour energy and nutrient intakes. In a randomized crossover counterbalanced design, 45 older adult Older American Act Nutrition Program participants received a regular and enhanced version of a lunch meal on alternate weeks. The types of foods, portion sizes (gram weight), and appearance of the lunch meal was held constant. Consumption of the enhanced meal increased average lunch energy intakes by 86% (P<0.001) and 24-hour energy intakes by 453 kcal (from 1,423.1+/-62.2 to 1,876.2+/-78.3 kcal, P<0.001). The 24-hour intakes of several key macronutrients and micronutrients also improved. These data suggest that altering the energy density of regularly served menu items is an effective strategy to improve dietary intakes of free-living older adults.

  8. Association of target organ damage with 24-hour systolic and diastolic blood pressure levels and hypertension subtypes in untreated Chinese.

    PubMed

    Wei, Fang-Fei; Li, Yan; Zhang, Lu; Xu, Ting-Yan; Ding, Feng-Hua; Staessen, Jan A; Wang, Ji-Guang

    2014-02-01

    The association of target organ damage with 24-hour systolic and diastolic blood pressure levels and ambulatory hypertension subtypes has not yet been examined in untreated Chinese patients. We measured left ventricular mass index by echocardiography (n=619), the urinary albumin:creatinine ratio (n=1047), and aortic pulse wave velocity by tonometry (n=1013) in 1047 untreated subjects (mean age, 50.6 years; 48.9% women). Normotension was a 24-hour systolic/diastolic blood pressure <130/<80 mm Hg. Hypertension subtypes were isolated diastolic hypertension and mixed systolic plus diastolic hypertension. We assessed associations of interest by multivariable-adjusted linear models. Using normotension as reference, mixed hypertension was associated with higher (P≤0.003) left ventricular mass index (+4.31 g/m(2)), urinary albumin:creatinine ratio (+1.63 mg/mmol), and pulse wave velocity (+0.76 m/s); and isolated diastolic hypertension was associated with similar left ventricular mass index and pulse wave velocity (P≥0.39), but higher urinary albumin:creatinine ratio (+1.24 mg/mmol; P=0.002). In younger participants (<55 years), the mutually independent effect sizes associated with 1 SD increases in 24-hour systolic/diastolic blood pressure were +3.31/-0.36 g/m(2) (P=0.009/0.79) for left ventricular mass index, +1.15/+1.14 mg/mmol (P=0.02/0.04) for the urinary albumin:creatinine ratio, and +0.54/-0.05 m/s (P<0.001/0.54) for pulse wave velocity. In older participants, these estimates were +3.58/+0.30 g/m(2) (P=0.045/0.88), +1.23/+1.05 mg/mmol (P=0.002/0.54), and +0.76/-0.49 m/s (P<0.001/<0.001), respectively. In conclusion, 24-hour systolic blood pressure and mixed hypertension are major determinants of target organ damage irrespective of age and target organ, whereas 24-hour diastolic blood pressure and isolated diastolic hypertension only relate to the urinary albumin:creatinine ratio below middle age.

  9. Microstructure of the rat's intake of food, sucrose and saccharin in 24-hour tests.

    PubMed

    Smith, J C

    2000-03-01

    A detailed description of a method for collecting meal and drinking bout patterns for the rat over 24-h preference tests is presented. Both the hardware and software are described for data collection with a 6-s resolution. As an example of the value of knowing the details of ingestive patterns, data are presented describing the meal and drinking bout patterns during daylong preference tests between sucrose or saccharin vs. water. During these two-day tests at each of a wide range of concentrations, the intake of powdered Purina Chow, sucrose and saccharin were observed and quantified into meals or bouts. The analysis allowed for a comparison of sucrose and saccharin ingestion in terms of number of bouts, duration of bouts, rate of licking during bouts, the juxtaposition of eating and drinking and the day/night patterns of intake. Comparisons of drinking during bouts were made with electrophysiological and short-term taste test data. The usefulness of microstructure analysis is discussed.

  10. Meal-induced 24-hour profile of circulating glycated insulin in type 2 diabetic subjects measured by a novel radioimmunoassay.

    PubMed

    Lindsay, John R; McKillop, Aine M; Mooney, Mark H; Flatt, Peter R; Bell, Patrick M; O'harte, Finbarr P M

    2003-05-01

    Increasing evidence supports a role for glycated insulin in the insulin-resistant state of type 2 diabetes. We measured 24-hour profiles of plasma glycated insulin, using a novel radioimmunoassay (RIA), to evaluate the effects of meal stimulation and intermittent fasting on circulating concentrations of plasma glycated insulin in type 2 diabetes. Patients (n = 6; hemoglobin A(1c) [HbA(1c)], 7.2% +/- 0.6%; fasting plasma glucose, 7.4 +/- 0.7 mmol/L; body mass index [BMI], 35.7 +/- 3.5 kg/m(2); age, 56.3 +/- 4.4 years) were admitted for 24 hours and received a standardized meal regimen. Half-hourly venous samples were taken for plasma glycated insulin, glucose, insulin, and C-peptide concentrations between 8 am and midnight and 2-hourly overnight. The mean plasma glycated insulin concentration over 24 hours was 27.8 +/- 1.2 pmol/L with a mean ratio of insulin:glycated insulin of 11:1. Circulating glucose, insulin, C-peptide, and glycated insulin followed a basal and meal-related pattern with most prominent increments following breakfast, lunch, and evening meal, respectively. The mean concentrations of glycated insulin during the morning, afternoon, evening, and night-time periods were 24.4 +/- 2.5, 28.7 +/- 2.3, 31.1 +/- 2.1, and 26.2 +/- 1.5 pmol/L, respectively, giving significantly higher molar ratios of insulin:glycated insulin of 18.0:1, 14.2:1, and 12.7:1 compared with 7.0:1 at night (P <.01 to P <.001). These data demonstrate that glycated insulin circulates at relatively high concentrations in type 2 diabetes with a diurnal pattern of basal and meal-stimulated release. A higher proportion of glycated insulin circulates at night suggestive of differences in metabolic clearance compared with native insulin.

  11. Effects of Fibrinogen Concentrate on Thrombin Generation, Thromboelastometry Parameters, and Laboratory Coagulation Testing in a 24-Hour Porcine Trauma Model

    PubMed Central

    Zentai, Christian; Solomon, Cristina; van der Meijden, Paola E. J.; Spronk, Henri M. H.; Schnabel, Jonas; Rossaint, Rolf

    2015-01-01

    Introduction: In a 24-hour porcine model of liver injury, we showed that fibrinogen supplementation does not downregulate endogenous fibrinogen synthesis. Here we report data from the same study showing the impact of fibrinogen on coagulation variables. Materials and Methods: Coagulopathy was induced in 20 German land race pigs by hemodilution and blunt liver injury. Animals randomly received fibrinogen concentrate (100 mg/kg) or saline. Coagulation parameters were assessed and thromboelastometry (ROTEM) was performed. Results: Fibrinogen concentrate significantly reduced the prolongations of EXTEM clotting time, EXTEM clot formation time, and prothrombin time induced by hemodilution and liver injury. A decrease in clot strength was also ameliorated. Endogenous thrombin potential was significantly higher in the fibrinogen group than in the control group, 20 minutes (353 ± 24 vs 289 ± 22 nmol/L·min; P < .05) and 100 minutes (315 ± 40 vs 263 ± 38 nmol/L·min; P < .05) after the start of infusion. However, no significant between-group differences were seen in other thrombin generation parameters or in d-dimer or thrombin–antithrombin levels. Fibrinogen–platelet binding was reduced following liver injury, with no significant differences between groups. No significant between-group differences were observed in any parameter at ∼12 and ∼24 hours. Conclusion: This study suggests that, in trauma, fibrinogen supplementation may shorten some measurements of the speed of coagulation initiation and produce a short-lived increase in endogenous thrombin potential, potentially through increased clotting substrate availability. Approximately 12 and 24 hours after starting fibrinogen concentrate/saline infusion, all parameters measured in this study were comparable in the 2 study groups. PMID:25948634

  12. The Relationship Between 24-Hour Symptoms and COPD Exacerbations and Healthcare Resource Use: Results from an Observational Study (ASSESS).

    PubMed

    Miravitlles, Marc; Worth, Heinrich; Soler-Cataluña, Juan José; Price, David; De Benedetto, Fernando; Roche, Nicolas; Godtfredsen, Nina S; van der Molen, Thys; Löfdahl, Claes-Göran; Padullés, Laura; Ribera, Anna

    2016-10-01

    This observational study assessed the relationship between nighttime, early-morning and daytime chronic obstructive pulmonary disease (COPD) symptoms and exacerbations and healthcare resource use. COPD symptoms were assessed at baseline in patients with stable COPD using a standardised questionnaire during routine clinical visits. Information was recorded on exacerbations and healthcare resource use during the year before baseline and during a 6-month follow-up period. The main objective of the analysis was to determine the predictive nature of current symptoms for future exacerbations and healthcare resource use. 727 patients were eligible (65.8% male, mean age: 67.2 years, % predicted forced expiratory volume in 1 second: 52.8%); 698 patients (96.0%) provided information after 6 months. Symptoms in any part of the day were associated with a prior history of exacerbations (all p < 0.05) and nighttime and early-morning symptoms were associated with the frequency of primary care visits in the year before baseline (both p < 0.01). During follow-up, patients with baseline symptoms during any part of the 24-hour day had more exacerbations than patients with no symptoms in each period (all p < 0.05); there was also an association between 24-hour symptoms and the frequency of primary care visits (all p ≤ 0.01). Although there was a significant association between early-morning and daytime symptoms and exacerbations during follow-up (both p < 0.01), significance was not maintained when adjusted for potential confounders. Prior exacerbations were most strongly associated with future risk of exacerbation. The results suggest 24-hour COPD symptoms do not independently predict future exacerbation risk.

  13. The Automated Self-Administered 24-Hour Dietary Recall for Children, 2012 version, for youth aged 9 to 11 Years: A validation study

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our objective was to validate the 2012 version of the Automated Self-Administered 24-Hour Dietary Recall for Children (ASA24-Kids-2012), a self-administered web-based 24-hour dietary recall (24hDR) instrument, among children aged 9 to 11 years, in two sites using a quasiexperimental design. In one s...

  14. A Plaque Disruption Index Identifies Patients with Non-STE-Type 1 Myocardial Infarction within 24 Hours of Troponin Positivity

    PubMed Central

    Al-Mohaissen, Maha A.; Carere, Ronald G.; Mancini, G. B. John; Humphries, Karin H.; Whalen, Beth A.; Lee, Terry; Scheuermeyer, Frank X.; Ignaszewski, Andrew P.

    2016-01-01

    Background Markers of plaque destabilization and disruption may have a role in identifying non-STE- type 1 Myocardial Infarction in patients presenting with troponin elevation. We hypothesized that a plaque disruption index (PDI) derived from multiple biomarkers and measured within 24 hours from the first detectable troponin in patients with acute non-STE- type 1 MI (NSTEMI-A) will confirm the diagnosis and identify these patients with higher specificity when compared to individual markers and coronary angiography. Methods We examined 4 biomarkers of plaque destabilization and disruption: myeloperoxidase (MPO), high-sensitivity interleukin-6, myeloid-related protein 8/14 (MRP8/14) and pregnancy-associated plasma protein-A (PAPP-A) in 83 consecutive patients in 4 groups: stable non-obstructive coronary artery disease (CAD), stable obstructive CAD, NSTEMI-A (enrolled within 24 hours of troponin positivity), and NSTEMI-L (Late presentation NSTEMI, enrolled beyond the 24 hour limit). The PDI was calculated and the patients’ coronary angiograms were reviewed for evidence of plaque disruption. The diagnostic performance of the PDI and angiography were compared. Results Compared to other biomarkers, MPO had the highest specificity (83%) for NSTEMI-A diagnosis (P<0.05). The PDI computed from PAPP-A, MRP8/14 and MPO was higher in NSTEMI-A patients compared to the other three groups (p<0.001) and had the highest diagnostic specificity (87%) with 79% sensitivity and 86% accuracy, which were higher compared to those obtained with MPO, but did not reach statistical significance (P>0.05 for all comparisons). The PDI had higher specificity and accuracy for NSTEMI-A diagnosis compared to coronary angiography (P<0.05). Conclusions A PDI measured within 24 hour of troponin positivity has potential to identify subjects with acute Non-ST-elevation type 1 MI. Additional evidence using other marker combinations and investigation in a sufficiently large non-selected cohort is warranted

  15. Sex difference in the near-24-hour intrinsic period of the human circadian timing system

    PubMed Central

    Duffy, Jeanne F.; Cain, Sean W.; Chang, Anne-Marie; Phillips, Andrew J. K.; Münch, Mirjam Y.; Gronfier, Claude; Wyatt, James K.; Dijk, Derk-Jan; Czeisler, Charles A.

    2011-01-01

    The circadian rhythms of melatonin and body temperature are set to an earlier hour in women than in men, even when the women and men maintain nearly identical and consistent bedtimes and wake times. Moreover, women tend to wake up earlier than men and exhibit a greater preference for morning activities than men. Although the neurobiological mechanism underlying this sex difference in circadian alignment is unknown, multiple studies in nonhuman animals have demonstrated a sex difference in circadian period that could account for such a difference in circadian alignment between women and men. Whether a sex difference in intrinsic circadian period in humans underlies the difference in circadian alignment between men and women is unknown. We analyzed precise estimates of intrinsic circadian period collected from 157 individuals (52 women, 105 men; aged 18–74 y) studied in a month-long inpatient protocol designed to minimize confounding influences on circadian period estimation. Overall, the average intrinsic period of the melatonin and temperature rhythms in this population was very close to 24 h [24.15 ± 0.2 h (24 h 9 min ± 12 min)]. We further found that the intrinsic circadian period was significantly shorter in women [24.09 ± 0.2 h (24 h 5 min ± 12 min)] than in men [24.19 ± 0.2 h (24 h 11 min ± 12 min); P < 0.01] and that a significantly greater proportion of women have intrinsic circadian periods shorter than 24.0 h (35% vs. 14%; P < 0.01). The shorter average intrinsic circadian period observed in women may have implications for understanding sex differences in habitual sleep duration and insomnia prevalence. PMID:21536890

  16. 24 hour forecast of the surface UV for the antipsoriatic heliotherapy in Poland.

    PubMed

    Krzyścin, J W; Guzikowski, J; Czerwińska, A; Lesiak, A; Narbutt, J; Jarosławski, J; Sobolewski, P S; Rajewska-Więch, B; Wink, J

    2015-07-01

    Analyses of the spectral and broad-band UV data collected at Belsk (20.79°E, 51.84°N), Poland, show that standard broad-band instrument, Solar Light (SL) 501A, could be used for measurements of both erythemal and antipsoriatic irradiance. A prognostic model is proposed for the next-day duration of outdoor exposure required to receive a dose, the so-called minimum antipsoriatic dose (MAD), equivalent to that received by standard antipsoriatic daily treatment in the phototherapy cabinet containing TL-01 fluorescent tubes. The model uses the 24 h forecast of the column amount of ozone (to predict next day clear sky UV irradiance), and low- and mid-level cloudiness (to estimate a reduction of the clear-sky UV irradiation due to clouds). The predicted duration of sunbathing required to receive a dose of 1 MAD matches the observed value, i.e. the correlation coefficients is 0.68. If the model predicts the antipsoriatic exposure over 1 MAD threshold the observed dose will be also above this threshold in 91% of cases. Thus, the model could be used for planning the next-day outdoor exposure to clear psoriasis. Hourly resolved maps, starting from 6 am up to 1 pm (GMT), showing the duration of antipsoriatic exposure over Poland are made public. The model provides a tool for a psoriatic patient to find the sunbathing starting time and its duration, which has the same healing potential as a single indoor phototherapy session.

  17. [Position statement. Protein/creatinine in a randomly obtained urine sample in the diagnosis of proteinuria in pregnant patients with arterial hypertension].

    PubMed

    2012-01-01

    Leaños Miranda and collaborators published that the measurement of protein/creatinine ratio in a single random urine sample is a reliable indicator of significant proteinuria and may be reasonably used as alternative to the 24-hours urine collection method as a diagnostic criteria for urinary protein, and it is also a criterion for identifying the disease severity. This leads us to present this successful result of the investigation as a position statement in the care of pregnant women with hypertension.

  18. DNA stability of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.

    PubMed

    Le Guern, Rémi; Miaux, Brigitte; Pischedda, Patricia; Herwegh, Stéphanie; Courcol, René

    2016-07-01

    We evaluated the DNA stability of Chlamydia trachomatis and Neisseria gonorrhoeae in 55 urine samples. Crossing threshold (Ct) values were highly similar after 3 to 14 days at room temperature (+0.002, P = 0.99). Consequently, it does not seem necessary to transfer urine specimens into a transport medium in less than 24 hours as recommended by manufacturers. PMID:27130478

  19. The impact of kidney transplantation on 24-hour ambulatory blood pressure in end-stage renal disease patients.

    PubMed

    Lee, Myung Hyun; Ko, Kyung Min; Ahn, Seung Won; Bae, Myoung Nam; Choi, Bum Soon; Park, Cheol Whee; Kim, Yong-Soo; Yang, Chul Woo; Chung, Byung Ha

    2015-06-01

    In this study, we prospectively investigated the impact of kidney transplantation (KT) on the status of hypertension, including circadian rhythm in end-stage renal disease (ESRD) patients. We performed 24-hour ambulatory blood pressure (BP) monitoring and office BP measurement in 48 patients before and 1 year after KT. According to the nocturnal reduction in systolic BP (ΔSBP), the patients were divided into dippers, non-dippers, and reverse dippers. After KT, the mean BP value in office BP and 24-hour ambulatory BP monitoring did not change, but the proportion of patients taking anti-hypertensive drugs and the pill number significantly decreased. In contrast, the mean ΔSBP significantly decreased, and the proportion of non-dippers and reverse dippers did not decrease. Decrease in ΔSBP after KT was associated with inferior allograft function during follow-up. Our study suggests that KT improved the overall BP level, but it did not affect abnormal circadian rhythm in ESRD patients. PMID:26051924

  20. Transcranial Direct Current Stimulation Augments Perceptual Sensitivity and 24-Hour Retention in a Complex Threat Detection Task

    PubMed Central

    Falcone, Brian; Coffman, Brian A.; Clark, Vincent P.; Parasuraman, Raja

    2012-01-01

    We have previously shown that transcranial direct current stimulation (tDCS) improved performance of a complex visual perceptual learning task (Clark et al. 2012). However, it is not known whether tDCS can enhance perceptual sensitivity independently of non-specific, arousal-linked changes in response bias, nor whether any such sensitivity benefit can be retained over time. We examined the influence of stimulation of the right inferior frontal cortex using tDCS on perceptual learning and retention in 37 healthy participants, using signal detection theory to distinguish effects on perceptual sensitivity (d′) from response bias (ß). Anodal stimulation with 2 mA increased d′, compared to a 0.1 mA sham stimulation control, with no effect on ß. On completion of training, participants in the active stimulation group had more than double the perceptual sensitivity of the control group. Furthermore, the performance enhancement was maintained for 24 hours. The results show that tDCS augments both skill acquisition and retention in a complex detection task and that the benefits are rooted in an improvement in sensitivity (d′), rather than changes in response bias (ß). Stimulation-driven acceleration of learning and its retention over 24 hours may result from increased activation of prefrontal cortical regions that provide top-down attentional control signals to object recognition areas. PMID:22511978

  1. Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

    NASA Technical Reports Server (NTRS)

    Engelke, K. A.; Shea, J. D.; Doerr, D. F.; Convertino, V. A.

    1992-01-01

    To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

  2. Transcranial direct current stimulation augments perceptual sensitivity and 24-hour retention in a complex threat detection task.

    PubMed

    Falcone, Brian; Coffman, Brian A; Clark, Vincent P; Parasuraman, Raja

    2012-01-01

    We have previously shown that transcranial direct current stimulation (tDCS) improved performance of a complex visual perceptual learning task (Clark et al. 2012). However, it is not known whether tDCS can enhance perceptual sensitivity independently of non-specific, arousal-linked changes in response bias, nor whether any such sensitivity benefit can be retained over time. We examined the influence of stimulation of the right inferior frontal cortex using tDCS on perceptual learning and retention in 37 healthy participants, using signal detection theory to distinguish effects on perceptual sensitivity (d') from response bias (ß). Anodal stimulation with 2 mA increased d', compared to a 0.1 mA sham stimulation control, with no effect on ß. On completion of training, participants in the active stimulation group had more than double the perceptual sensitivity of the control group. Furthermore, the performance enhancement was maintained for 24 hours. The results show that tDCS augments both skill acquisition and retention in a complex detection task and that the benefits are rooted in an improvement in sensitivity (d'), rather than changes in response bias (ß). Stimulation-driven acceleration of learning and its retention over 24 hours may result from increased activation of prefrontal cortical regions that provide top-down attentional control signals to object recognition areas.

  3. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... is used to measure the amounts of various immunoglobulins in urine. Most often, it is done after ...

  4. Establishing normal plasma and 24-hour urinary biochemistry ranges in C3H, BALB/c and C57BL/6J mice following acclimatization in metabolic cages.

    PubMed

    Stechman, Michael J; Ahmad, Bushra N; Loh, Nellie Y; Reed, Anita A C; Stewart, Michelle; Wells, Sara; Hough, Tertius; Bentley, Liz; Cox, Roger D; Brown, Steve D M; Thakker, Rajesh V

    2010-07-01

    Physiological studies of mice are facilitated by normal plasma and 24-hour urinary reference ranges, but variability of these parameters may increase due to stress that is induced by housing in metabolic cages. We assessed daily weight, food and water intake, urine volume and final day measurements of the following: plasma sodium, potassium, chloride, urea, creatinine, calcium, phosphate, alkaline phosphatase, albumin, cholesterol and glucose; and urinary sodium, potassium, calcium, phosphate, glucose and protein in 24- to 30-week-old C3H/HeH, BALB/cAnNCrl and C57BL/6J mice. Between 15 and 20 mice of each sex from all three strains were individually housed in metabolic cages with ad libitum feeding for up to seven days. Acclimatization was evaluated using general linear modelling for repeated measures and comparison of biochemical data was by unpaired t-test and analysis of variance (SPSS version 12.0.1). Following an initial 5-10% fall in body weight, daily dietary intake, urinary output and weight in all three strains reached stable values after 3-4 days of confinement. Significant differences in plasma glucose, cholesterol, urea, chloride, calcium and albumin, and urinary glucose, sodium, phosphate, calcium and protein were observed between strains and genders. Thus, these results provide normal reference values for plasma and urinary biochemistry in three strains housed in metabolic cages and demonstrate that 3-4 days are required to reach equilibrium in metabolic cage studies. These variations due to strain and gender have significant implications for selecting the appropriate strain upon which to breed genetically-altered models of metabolic and renal disease.

  5. Ultra-Rapid dUT1 Measurements on Japan-Fennoscandian Baselines - Application to 24-hour Sessions

    NASA Technical Reports Server (NTRS)

    Matsuzaka, Shigeru; Kurihara, Shinobu; Sekido, Mamoru; Hobiger, Thomas; Haas, Rudiger; Ritakari, Jouko; Wagner, Jan

    2010-01-01

    GSI, NICT, OSO, and MRO have been engaged in Ultra-rapid dUT1 experiments since 2007 aiming at the technological possibility of real-time dUT1 results using the e-VLBI technique. We have already successfully determined dUT1 in less than four minutes after the end of an experimental Intensive session in 2008, and at present we routinely get the results within 30 minutes for regular Intensives. In 2009 we applied the technique to 24-hour sessions and continuously obtained dUT1 values by processing and analyzing Tsukuba Onsala data in near real-time. It showed a detailed behavior of UT1 variations, which could be very valuable for scientific study as well as for precise prediction of UT1-UTC.

  6. Pink urine.

    PubMed

    Verhoeven, E; Capron, A; Hantson, P

    2014-11-01

    A 55-year-old man was admitted after a suspected hypnotic overdose of valerian extracts. In addition to altered consciousness, the first clinical symptoms included not only diffuse rash on the face, trunk, and limbs, but also an inspiratory dyspnea with a marked hypoxemia. A major laryngeal edema was noted during orotracheal intubation. After correction of hypoxemia, the patient became agitated and propofol was administered by continuous infusion. In addition, the patient passed pink urine staining the urine collection bag. The presence of an unidentified toxic substance was suspected. PMID:25233954

  7. 49 CFR 40.43 - What steps must operators of collection sites take to protect the security and integrity of urine...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... following before each collection to deter tampering with specimens: (1) Secure any water sources or... 49 Transportation 1 2013-10-01 2013-10-01 false What steps must operators of collection sites take to protect the security and integrity of urine collections? 40.43 Section 40.43 Transportation...

  8. Prognostic Value of the 24-Hour Neurological Examination in Anterior Circulation Ischemic Stroke: A post hoc Analysis of Two Randomized Controlled Stroke Trials

    PubMed Central

    Rangaraju, Srikant; Frankel, Michael; Jovin, Tudor G.

    2016-01-01

    Background Early prognostication of long-term outcomes following ischemic stroke can facilitate medical decision-making. We hypothesized that the 24-hour National Institute of Health Stroke Scale (NIHSS) predicts 3-month clinical outcomes in anterior circulation stroke. Methods Secondary analyses of the Interventional Management of Stroke 3 (IMS3) and intravenous tissue plasminogen activator (IV tPA) for acute ischemic stroke [National Institute of Neurological Diseases and Stroke (NINDS) IV tPA] trials were performed. In participants with documented 24-hour NIHSS and 3-month Modified Rankin Scale (mRS), the predictive power of the 24-hour NIHSS and 24-hour NIHSS improvement for 3-month outcomes [mRS 0-2 and Barthel Index (BI) ≥95] was assessed. Percentages of good outcome (mRS 0-2 or BI ≥95) at 3, 6, and 12 months and mean quality of life (EQ5D™) index at 3 months across 24-hour NIHSS quartiles were compared. Results The majority of the study participants were included (IMS3 n = 587/656, NINDS IV tPA n = 619/624). The 24-hour NIHSS was correlated with 3-month mRS (R = 0.73) with excellent predictive power for mRS 0-2 [area under the curve (AUC) = 0.91] and BI ≥95 (AUC = 0.9) in both cohorts. A model with the 24-hour NIHSS alone correctly classified 82-84% of patients in both cohorts. The percentages of good outcomes at 3-12 months across 24-hour NIHSS quartiles were similar in both cohorts. mRS 0-2 was achieved by 75.6-77.7% of patients with 24-hour NIHSS ≤11 but by only 1.4-3.6% with 24-hour NIHSS ≥20. The EQ5D index at 3 months varied among NIHSS 0-4 (mean 0.86 ± 0.16), 5-11 (0.77 ± 0.18), and 12-19 (0.59 ± 0.26) quartiles. Conclusions The 24-hour NIHSS strongly predicts long-term stroke outcomes and is associated with quality of life. Its easy availability, reliability, and validity support its use as an early prognostic marker and surrogate of clinical outcome in ischemic stroke. PMID:27051408

  9. Urine sample (image)

    MedlinePlus

    ... catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head of the penis. Women or girls need to wash the area between the lips of the vagina with soapy water and rinse well. A small amount of urine ...

  10. Porphyrins - urine

    MedlinePlus

    ... results may be due to: Liver cancer Hepatitis Lead poisoning Porphyria (several types) Alternative Names Urine uroporphyrin; Urine ... More Delta-ALA urine test Enzyme Hemoglobin Hepatitis Lead poisoning Liver cancer - hepatocellular carcinoma PBG urine test Porphyria ...

  11. Label-free mass spectrometry proteome quantification of human embryonic kidney cells following 24 hours of sialic acid overproduction

    PubMed Central

    2013-01-01

    Background Cell surface glycoprotein sialylation is one of the most ubiquitous glycan modifications found on higher eukaryotes. The surface sialylation pattern of cells is influenced by the cellular environment but also by the Golgi sialyltransferase activity and flux of metabolites through sialic acid producing pathways. Altered cell surface sialic acid patterns have been observed in several cancers and other pathological conditions. In this experiment we examined the cellular proteomic changes that occur in human embryonic kidney cells after 24 hours of sialic acid overproduction using N-Acetylmannosamine. We utilized high resolution mass spectrometry and label free protein quantification to characterize the relative changes in protein abundance as well as multiple reaction monitoring to quantify the cellular sialic acid levels. Results Using N-Acetylmannosamine we were able to induce sialic acid production to almost 70-fold compared to non-induced control cells. Mass spectrometric analysis of cellular proteome of control and induced cells identified 1802 proteins of which 105 displayed significant changes in abundance. Functional analysis of the resulting relative changes in protein abundance revealed regulation of several cellular pathways including protein transport, metabolic and signaling pathways and remodeling of epithelial adherens junctions. We also identified several physically interacting co-regulated proteins in the set of changed proteins. Conclusions In this experiment we show that increased metabolic flux through sialic acid producing pathway affects the abundance of several protein transport, epithelial adherens junction, signaling and metabolic pathway related proteins. PMID:23915316

  12. Once- and twice-daily bevantolol for systemic hypertension using 24-hour ambulatory intraarterial blood pressure recording.

    PubMed

    Al-Khawaja, I M; Caruana, M P; Prince, H; Whittington, J; Raftery, E B

    1986-11-26

    The antihypertensive efficacy of bevantolol, a selective beta 1-adrenoreceptor antagonist, was evaluated in 17 patients with essential hypertension, using continuous ambulatory intraarterial blood pressure (BP) monitoring. The study compared a twice-daily regimen (titrated dose of 200 to 600 mg/day) with the same amount given in a single daily dose. Within-patient comparisons of mean hourly systolic and diastolic BPs and heart rate showed a highly significant effect with twice-daily therapy (p less than 0.001) for all of the 24 hours. Similar significant results were obtained with a single morning dose. There was no difference between the pattern or extent of BP reduction with the 2 regimens. The decrease in BP after bevantolol persisted during the physiologic tests (rest, tilt, isometric and dynamic exercise). Four patients developed minor side effects with the single morning dose, and only 1 patient with the twice-daily regimen. These effects included tiredness, fatigue and dizziness. Unlike pure beta-blocking agents, bevantolol controlled the early morning increase in BP, lending support to the belief that it possesses vasodilatory properties in addition to beta blockade. These results suggest that bevantolol may be useful as first-line therapy in a once-daily dosage for the treatment of essential hypertension.

  13. A comparison of regression and Bayesian change point analysis for extreme 24hours rainfall in South Australia

    NASA Astrophysics Data System (ADS)

    Kamruzzaman, M.; Beecham, S.; Metcalfe, A.

    2013-12-01

    We consider monthly extremes rainfall, aggregated over 24 hours, at 24 rainfall station in South Australia (SA). A self-organizing map (SOM) technique is used to draw contours of extreme for this area for each month. The possibility of change in extreme rainfall is investigated in two ways. The first is a multiple regression with time, month, station and their interaction as predictor variables. A confidence interval and for the linear and quadratic effects of time series are given. We have developed a strategy to possible improve prediction of extreme rainfall as a linear combination of original prediction. The dramatic improvement is a consequence of introducing squares and cross product of predictor variables is given in calibration, validation and re-calibration model. The similarity between fitted to the calibration and validation periods suggests that the hydrological process have been relatively stable over the period. The modeling strategy is empirical and will valid for different time period; although, in general, estimated coefficients could change substantially. The second analysis is a Bayesian change's point (BCP) analysis based on deseasonalised extreme data. A univariate BCP is applied in the data averaged over stations and compared with a multivariate BCP applied to the individual station records. The BCP is applied to investigate the possibility of sudden change rather than a smooth trend.

  14. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome.

    PubMed

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support. PMID:27398166

  15. Relative prognostic value of rest thallium-201 imaging, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring after acute myocardial infarction

    SciTech Connect

    Hakki, A.H.; Nestico, P.F.; Heo, J.; Unwala, A.A.; Iskandrian, A.S.

    1987-07-01

    Rest thallium-201 scintigraphy, radionuclide ventriculography and 24 hour Holter monitoring are acceptable methods to assess myocardial necrosis, performance and electrical instability. This study examined the relative value of the three tests, when obtained a mean of 7 days after acute myocardial infarction, in predicting 1 year mortality in 93 patients. Planar thallium-201 images were obtained in three projections and were scored on a scale of 0 to 4 in 15 segments (normal score = 60). Patients were classified as having high risk test results as follows: thallium score less than or equal to 45 (33 patients), left ventricular ejection fraction less than or equal to 40% (51 patients) and complex ventricular arrhythmias on Holter monitoring (36 patients). During the follow-up of 6.4 +/- 3.4 months (mean +/- SD), 15 patients died of cardiac causes. All three tests were important predictors of survival by univariate Cox survival analysis; the thallium score, however, was the only important predictor by multivariate analysis. The predictive power of the thallium score was comparable with that of combined ejection fraction and Holter monitoring (chi-square = 21 versus chi-square = 22). Thus, rest thallium-201 imaging performed before hospital discharge provides important prognostic information in survivors of acute myocardial infarction which is comparable with that provided by left ventricular ejection fraction and Holter monitoring. Patients with a lower thallium score (large perfusion defects) are at high risk of cardiac death during the first year after infarction.

  16. Adrenal catecholamine synthesis rate changes induced by combined thermal and immobilization stress in fed and 24 hour fasted rats.

    PubMed

    Bargiel, Z; Nowicka, H

    1989-01-01

    The combined stress of acute immobilization (IM) at high and low ambient temperature has been used to determine its influence on adrenal catecholamine (CA) content assassed histofluorimetrically in fed and 24 hour fasted rats. The general course of changes obtained after the arrangement of adrenal strips deriving from the adrenals of rats exposed to cold and IM stress (CIMS) at +10 degrees C to -25 degrees C during the different time fragments presented the adrenal CA depletion events followed sometimes by the adrenal CA content increase after the longer stress exposure or/and stronger CIMS and WIMS conditions. It was found that this depletion-stimulated increase of adrenal Ca synthesis rate had been accelerated in 24 h fasted rats compared to satiated ones exposed to the same stress conditions, especially after the CIMS exposure. Moreover the survival time duration at first lethal temperature (-5 degrees C and +45 degrees C) was significantly higher in fasted rats. The possible hypothalamic regulation of adrenal CA synthesis rate accordingly to the actual metabolism needs and beta-adrenoceptor sensitivity changes depending on satiety state have been discussed and the necessity of further investigations concerning the specificity of stress-induced metabolism changes in 24 h starved rats has been suggested.

  17. Hourly thermal load prediction for the next 24 hours by ARIMA, EWMA, LR and an artificial neural network

    SciTech Connect

    Kawashima, Minoru; Dorgan, C.E.; Mitchell, J.W.

    1995-08-01

    Predicting the thermal load for the next 24 hours is essential for optimal control of heating, ventilating, and air conditioning (HVAC) systems that use thermal cool storage. It can be useful in minimizing costs and energy in nonstorage systems. A cooperative research project between a US. university and a Japanese corporation investigated four generally used prediction methods to examine the basic models with variations and to compare the accuracy of each model. A cooling and heating seasonal data set with known next-day weather was used to evaluate the accuracy of each prediction method. The results indicate that an artificial neural network (ANN) model produces the most accurate thermal load predictions. After the initial comparisons with a computer-generated data set, the ANN model was applied to two measured building loads from another research project. These sets included typical measurement noise related to continuous field monitoring. The predictions of the next-day cooling load using the ANN prediction model were close to the actual data, even when the next-day weather was forecast. This confirms that the ANN model has sufficient accuracy and is the correct method for practical utilization in HVAC system control, thermal storage optimal control, and load/demand management.

  18. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome

    PubMed Central

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support. PMID:27398166

  19. Extracorporeal membrane oxygenation improves survival in a novel 24-hour pig model of severe acute respiratory distress syndrome.

    PubMed

    Araos, Joaquín; Alegría, Leyla; García, Patricio; Damiani, Felipe; Tapia, Pablo; Soto, Dagoberto; Salomon, Tatiana; Rodriguez, Felipe; Amthauer, Macarena; Erranz, Benjamín; Castro, Gabriel; Carreño, Pamela; Medina, Tania; Retamal, Jaime; Cruces, Pablo; Bugedo, Guillermo; Bruhn, Alejandro

    2016-01-01

    Extracorporeal membrane oxygenation (ECMO) is increasingly being used to treat severe acute respiratory distress syndrome (ARDS). However, there is limited clinical evidence about how to optimize the technique. Experimental research can provide an alternative to fill the actual knowledge gap. The purpose of the present study was to develop and validate an animal model of acute lung injury (ALI) which resembled severe ARDS, and which could be successfully supported with ECMO. Eighteen pigs were randomly allocated into three groups: sham, ALI, and ALI + ECMO. ALI was induced by a double-hit consisting in repeated saline lavage followed by a 2-hour period of injurious ventilation. All animals were followed up to 24 hours while being ventilated with conventional ventilation (tidal volume 10 ml/kg). The lung injury model resulted in severe hypoxemia, increased airway pressures, pulmonary hypertension, and altered alveolar membrane barrier function, as indicated by an increased protein concentration in bronchoalveolar fluid, and increased wet/dry lung weight ratio. Histologic examination revealed severe diffuse alveolar damage, characteristic of ARDS. Veno-venous ECMO was started at the end of lung injury induction with a flow > 60 ml/kg/min resulting in rapid reversal of hypoxemia and pulmonary hypertension. Mortality was 0, 66.6 and 16.6% in the SHAM, ALI and ALI + ECMO groups, respectively (p < 0.05). This is a novel clinically relevant animal model that can be used to optimize the approach to ECMO and foster translational research in extracorporeal lung support.

  20. Famprofazone as the source of methamphetamine and amphetamine in urine specimen collected during sport competition.

    PubMed

    Tseng, Ying Lung; Lin, Chien-Tzong; Wang, Sheng-Meng; Liu, Ray H

    2007-03-01

    During a sport competition event in Taiwan, one urine specimen was found positive for both methamphetamine (2688 ng/mL) and amphetamine (462 ng/mL). The specimen donor claimed that she had taken Gewolen (a nonprescription drug manufactured in Taiwan) for treating abdominal pain and the medication was presented. Laboratory investigation confirmed that Gewolen contains famprofazone, which is known to metabolize to methamphetamine and amphetamine and is included in the prohibited list of the World Anti-Doping Agency. Study on the excretion profiles of three volunteers ingesting 50 mg famprofazone produced the following patterns similar to that observed in the case specimen: (a) the ratio of methamphetamine to amphetamine was approximately 6 to 1; (b) d- and l-enantiomers of both methamphetamine and amphetamine were present, while the amount of l-methamphetamine was 3-4-fold greater than its counterpart. The data suggested that famprofazone (as the ingredient of Gewolen) was likely the source of the prohibited drugs found in the case specimen.

  1. The QuickWee trial: protocol for a randomised controlled trial of gentle suprapubic cutaneous stimulation to hasten non-invasive urine collection from infants

    PubMed Central

    Kaufman, Jonathan; Fitzpatrick, Patrick; Tosif, Shidan; Hopper, Sandy M; Bryant, Penelope A; Donath, Susan M; Babl, Franz E

    2016-01-01

    Introduction Urinary tract infections (UTIs) are common in young children. Urine sample collection is required to diagnose or exclude UTI; however, current collection methods for pre-continent children all have limitations and guidelines vary. Clean catch urine (CCU) collection is a common and favoured non-invasive collection method, despite its high contamination rates and time-consuming nature. This study aims to establish whether gentle suprapubic cutaneous stimulation with cold fluid-soaked gauze can improve the rate of voiding for CCU within 5 min in young pre-continent children. Methods and analysis This study is a randomised controlled trial of 354 infants (aged 1–12 months) who require urine sample collection, conducted in a single emergency department in a tertiary paediatric hospital in Melbourne, Australia. After standard urogenital cleaning, patients will be randomised to either a novel technique of suprapubic cutaneous stimulation using cold saline-soaked gauze in circular motions or no stimulation. The study period is 5 min, after which care is determined by the treating clinician if a urine sample has not been collected. Primary outcome: whether the child voids within 5 min (yes/no). Secondary outcomes: parental and clinician satisfaction with the method, success in catching a urine sample if the child voids, and sample contamination rates. This trial will allow the definitive assessment of this novel technique, gentle suprapubic cutaneous stimulation with cold saline-soaked gauze, and its utility to hasten non-invasive urine collection in infants. Ethics and dissemination The study has hospital ethics approval and is registered with the Australian New Zealand Clinical Trials Registry—ACTRN12615000754549. The results of the study will be published in a peer-reviewed journal. Trial registration number ACTRN12615000754549; Pre-results. PMID:27515752

  2. Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep.

    PubMed

    Tremblay, Mark S; Carson, Valerie; Chaput, Jean-Philippe; Connor Gorber, Sarah; Dinh, Thy; Duggan, Mary; Faulkner, Guy; Gray, Casey E; Gruber, Reut; Janson, Katherine; Janssen, Ian; Katzmarzyk, Peter T; Kho, Michelle E; Latimer-Cheung, Amy E; LeBlanc, Claire; Okely, Anthony D; Olds, Timothy; Pate, Russell R; Phillips, Andrea; Poitras, Veronica J; Rodenburg, Sophie; Sampson, Margaret; Saunders, Travis J; Stone, James A; Stratton, Gareth; Weiss, Shelly K; Zehr, Lori

    2016-06-01

    Leaders from the Canadian Society for Exercise Physiology convened representatives of national organizations, content experts, methodologists, stakeholders, and end-users who followed rigorous and transparent guideline development procedures to create the Canadian 24-Hour Movement Guidelines for Children and Youth: An Integration of Physical Activity, Sedentary Behaviour, and Sleep. These novel guidelines for children and youth aged 5-17 years respect the natural and intuitive integration of movement behaviours across the whole day (24-h period). The development process was guided by the Appraisal of Guidelines for Research Evaluation (AGREE) II instrument and systematic reviews of evidence informing the guidelines were assessed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. Four systematic reviews (physical activity, sedentary behaviour, sleep, integrated behaviours) examining the relationships between and among movement behaviours and several health indicators were completed and interpreted by expert consensus. Complementary compositional analyses were performed using Canadian Health Measures Survey data to examine the relationships between movement behaviours and health indicators. A stakeholder survey was employed (n = 590) and 28 focus groups/stakeholder interviews (n = 104) were completed to gather feedback on draft guidelines. Following an introductory preamble, the guidelines provide evidence-informed recommendations for a healthy day (24 h), comprising a combination of sleep, sedentary behaviours, light-, moderate-, and vigorous-intensity physical activity. Proactive dissemination, promotion, implementation, and evaluation plans have been prepared in an effort to optimize uptake and activation of the new guidelines. Future research should consider the integrated relationships among movement behaviours, and similar integrated guidelines for other age groups should be developed. PMID:27306437

  3. Risk Stratification by 24-Hour Ambulatory Blood Pressure and Estimated Glomerular Filtration Rate in 5322 Subjects From 11 Populations

    PubMed Central

    Boggia, José; Thijs, Lutgarde; Li, Yan; Hansen, Tine W.; Kikuya, Masahiro; Björklund-Bodegård, Kristina; Ohkubo, Takayoshi; Jeppesen, Jørgen; Torp-Pedersen, Christian; Dolan, Eamon; Kuznetsova, Tatiana; Stolarz-Skrzypek, Katarzyna; Tikhonoff, Valérie; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Schwedt, Emma; Sandoya, Edgardo; Kawecka-Jaszcz, Kalina; Filipovský, Jan; Imai, Yutaka; Wang, Jiguang; Ibsen, Hans; O’Brien, Eoin; Staessen, Jan A.

    2013-01-01

    No previous study addressed whether in the general population estimated glomerular filtration rate (eGFR [Chronic Kidney Disease Epidemiology Collaboration formula]) adds to the prediction of cardiovascular outcome over and beyond ambulatory blood pressure. We recorded health outcomes in 5322 subjects (median age, 51.8 years; 43.1% women) randomly recruited from 11 populations, who had baseline measurements of 24-hour ambulatory blood pressure (ABP24) and eGFR. We computed hazard ratios using multivariable-adjusted Cox regression. Median follow-up was 9.3 years. In fully adjusted models, which included both ABP24 and eGFR, ABP24 predicted (P≤0.008) both total (513 deaths) and cardiovascular (206) mortality; eGFR only predicted cardiovascular mortality (P=0.012). Furthermore, ABP24 predicted (P≤0.0056) fatal combined with nonfatal events as a result of all cardiovascular causes (555 events), cardiac disease (335 events), or stroke (218 events), whereas eGFR only predicted the composite cardiovascular end point and stroke (P≤0.035). The interaction terms between ABP24 and eGFR were all nonsignificant (P≥0.082). For cardiovascular mortality, the composite cardiovascular end point, and stroke, ABP24 added 0.35%, 1.17%, and 1.00% to the risk already explained by cohort, sex, age, body mass index, smoking and drinking, previous cardiovascular disease, diabetes mellitus, and antihypertensive drug treatment. Adding eGFR explained an additional 0.13%, 0.09%, and 0.14%, respectively. Sensitivity analyses stratified for ethnicity, sex, and the presence of hypertension or chronic kidney disease (eGFR <60 mL/min per 1.73 m2) were confirmatory. In conclusion, in the general population, eGFR predicts fewer end points than ABP24. Relative to ABP24, eGFR is as an additive, not a multiplicative, risk factor and refines risk stratification 2- to 14-fold less. PMID:23172928

  4. 49 CFR Appendix A to Part 40 - DOT Standards for Urine Collection Kits

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sealed plastic bag or shrink wrapping; or must have a peelable, sealed lid or other easily visible tamper...) together in a sealed plastic bag or shrink wrapping separate from the collection container; or must be wrapped (with cap) individually in sealed plastic bags or shrink wrapping; or must have peelable,...

  5. 49 CFR Appendix A to Part 40 - DOT Standards for Urine Collection Kits

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sealed plastic bag or shrink wrapping; or must have a peelable, sealed lid or other easily visible tamper...) together in a sealed plastic bag or shrink wrapping separate from the collection container; or must be wrapped (with cap) individually in sealed plastic bags or shrink wrapping; or must have peelable,...

  6. 49 CFR Appendix A to Part 40 - DOT Standards for Urine Collection Kits

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sealed plastic bag or shrink wrapping; or must have a peelable, sealed lid or other easily visible tamper...) together in a sealed plastic bag or shrink wrapping separate from the collection container; or must be wrapped (with cap) individually in sealed plastic bags or shrink wrapping; or must have peelable,...

  7. 49 CFR Appendix A to Part 40 - DOT Standards for Urine Collection Kits

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sealed plastic bag or shrink wrapping; or must have a peelable, sealed lid or other easily visible tamper...) together in a sealed plastic bag or shrink wrapping separate from the collection container; or must be wrapped (with cap) individually in sealed plastic bags or shrink wrapping; or must have peelable,...

  8. 49 CFR Appendix A to Part 40 - DOT Standards for Urine Collection Kits

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... sealed plastic bag or shrink wrapping; or must have a peelable, sealed lid or other easily visible tamper...) together in a sealed plastic bag or shrink wrapping separate from the collection container; or must be wrapped (with cap) individually in sealed plastic bags or shrink wrapping; or must have peelable,...

  9. Prevalence of Masked Hypertension: a Population-Based Survey in a Large City by Using 24-Hour Ambulatory Blood Pressure Monitoring

    PubMed Central

    Kim, Sun-Woong; Choi, Eun-Hee; Kim, Ji-Hyun; Nah, Deuk-Young; Shin, Sung-Joon; Gu, Namyi

    2016-01-01

    Background and Objectives We estimated the prevalence of hypertension and hypertension subtypes in a large semi-urban city in Korea, using 24-hour ambulatory blood pressure monitoring (ABPM) in a randomly selected sample population. Subjects and Methods A random sample (aged 20-65 years) from a city with an adult population of approximately 600000 was selected by using a list-assisted random digit dialing method. The 24-hour ABPM and conventional blood pressure measurement (CBPM) of these individuals were obtained. Results Among the 496 participants, valid 24-hour ABPM and CBPM were obtained from 462 (93%) individuals. The estimated prevalence of hypertension in Goyang was 17.54% by CBPM and 32.70% by 24-hour ABPM (p<0.01). In the age stratified analysis, both CBPM and 24-hour ABPM showed increased prevalence of hypertension with age. The estimated prevalence of masked hypertension was 16.22% and that of white-coat hypertension was 1.08%. Men had a higher prevalence of masked hypertension than women (20.79% vs. 11.86%, p=0.0295). The estimated prevalence of masked hypertension was 17.5%, 20.58%, 24.34%, and 13.29% in the age categories of 30s, 40s, 50s, and 60s, respectively. The estimated prevalence of masked uncontrolled hypertension was 26.79% in patients with hypertension who were taking antihypertensive medications. Conclusion The estimated prevalence of hypertension by 24-hour ABPM was higher than that by CBPM, revealing high prevalence of masked hypertension. The high prevalence of masked hypertension supports the adoption of ABPM in the national population survey and clinical practice to improve public health and reduce health care costs. PMID:27721860

  10. Accuracy of children's school-breakfast reports and school-lunch reports (in 24-hour dietary recalls) differs by retention interval

    PubMed Central

    Baxter, Suzanne Domel; Guinn, Caroline H.; Royer, Julie A.; Hardin, James W.; Mackelprang, Alyssa J.; Smith, Albert F.

    2009-01-01

    Background/Objectives Validation-study data were analyzed to investigate the effect of retention interval (time between the to-be-reported meal and interview) on accuracy of children's school-breakfast reports and school-lunch reports in 24-hour recalls, and to compare accuracy of children's school-breakfast reports for two breakfast locations (classroom; cafeteria). Subjects/Methods Each of 374 fourth-grade children was interviewed to obtain a 24-hour recall using one of six conditions from crossing two target periods (prior 24 hours; previous day) with three interview times (morning; afternoon; evening). Each condition had 62 or 64 children (half boys). A recall's target period included one school breakfast and one school lunch, for which the child had been observed. Food-item variables (observed number; reported number; omission rate; intrusion rate) and energy variables (observed; reported; report rate; correspondence rate; inflation ratio) were calculated for each child for school breakfast and school lunch separately. Results Accuracy for school-breakfast reports and school-lunch reports was inversely related to retention interval. Specifically, as indicated by smaller omission rates, smaller intrusion rates, larger correspondence rates, and smaller inflation ratios, accuracy for school-breakfast reports was best for prior-24-hour recalls in the morning, and accuracy for school-lunch reports was best for prior-24-hour recalls in the afternoon. For neither school meal was a significant sex effect found for any variable. For school-breakfast reports, there was no significant school-breakfast location effect for any variable. Conclusions By shortening the retention interval, accuracy can be improved for school-breakfast reports and school-lunch reports in children's 24-hour recalls. PMID:19756033

  11. Computerized portion-size estimation compared to multiple 24-hour dietary recalls for measurement of fat, fruit, and vegetable intake in overweight adults.

    PubMed

    Toobert, Deborah J; Strycker, Lisa A; Hampson, Sarah E; Westling, Erika; Christiansen, Steven M; Hurley, Thomas G; Hébert, James R

    2011-10-01

    Validated self-report methods of dietary assessment exist and might be improved in terms of both accuracy and cost-efficiency with computer technology. The objectives of this preliminary study were to develop an initial version of an interactive CD-ROM program to estimate fruit, vegetable, and fat intake, and to compare it to multiple 24-hour dietary recalls (averaged over 3 days). In 2009, overweight male and female adults (n=205) from Lane County, OR, completed computerized and paper versions of fruit, vegetable, and fat screening instruments, and multiple 24-hour dietary recalls. Summary scores from the 10-item National Cancer Institute Fruit and Vegetable Scan and the 18-item Block Fat Screener were compared to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake estimates (criterion measures). Measurement models were used to derive deattenuated correlations with multiple 24-hour dietary recalls of paper and CD-ROM administrations of Fruit and Vegetable Scan fruit intake, vegetable intake, and fruit and vegetable intake, and Block Fat Screener fat intake. The computerized assessment and paper surveys were related to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake. Deattenuated correlation coefficients ranged from 0.50 to 0.73 (all P≤0.0001). The CD-ROM-derived estimate of fruit intake was more closely associated with 24-hour dietary recall (r=0.73) than the paper-derived estimate (r=0.54; P<0.05), but the other comparisons did not differ significantly. Findings from this preliminary study with overweight adults indicate the need for additional enhancements to the CD-ROM assessment and more extensive validation studies.

  12. Computerized portion-size estimation compared to multiple 24-hour dietary recalls for measurement of fat, fruit, and vegetable intake in overweight adults.

    PubMed

    Toobert, Deborah J; Strycker, Lisa A; Hampson, Sarah E; Westling, Erika; Christiansen, Steven M; Hurley, Thomas G; Hébert, James R

    2011-10-01

    Validated self-report methods of dietary assessment exist and might be improved in terms of both accuracy and cost-efficiency with computer technology. The objectives of this preliminary study were to develop an initial version of an interactive CD-ROM program to estimate fruit, vegetable, and fat intake, and to compare it to multiple 24-hour dietary recalls (averaged over 3 days). In 2009, overweight male and female adults (n=205) from Lane County, OR, completed computerized and paper versions of fruit, vegetable, and fat screening instruments, and multiple 24-hour dietary recalls. Summary scores from the 10-item National Cancer Institute Fruit and Vegetable Scan and the 18-item Block Fat Screener were compared to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake estimates (criterion measures). Measurement models were used to derive deattenuated correlations with multiple 24-hour dietary recalls of paper and CD-ROM administrations of Fruit and Vegetable Scan fruit intake, vegetable intake, and fruit and vegetable intake, and Block Fat Screener fat intake. The computerized assessment and paper surveys were related to multiple 24-hour dietary recall-derived fruit/vegetable and fat intake. Deattenuated correlation coefficients ranged from 0.50 to 0.73 (all P≤0.0001). The CD-ROM-derived estimate of fruit intake was more closely associated with 24-hour dietary recall (r=0.73) than the paper-derived estimate (r=0.54; P<0.05), but the other comparisons did not differ significantly. Findings from this preliminary study with overweight adults indicate the need for additional enhancements to the CD-ROM assessment and more extensive validation studies. PMID:21963026

  13. Reference intervals for the markers of proteinuria with a standardised bed-rest collection of urine.

    PubMed

    Kouri, T; Harmoinen, A; Laurila, K; Ala-Houhala, I; Koivula, T; Pasternack, A

    2001-05-01

    Reference intervals for markers of proteinuria or glomerular charge selectivity were measured in 61 healthy female and 61 healthy male individuals. Timed bed-rest and daytime collections were used to assess significance of preanalytical variability of results. Bed-rest collections are advisable for research on renal damage, whereas in routine care, robust protein/creatinine ratios work as practical estimates of protein excretion rates, the correlations to excretion rates improving with increasing proteinuria. For glomerular charge selectivity, pancreatic/salivary isoamylase clearance ratio showed lower within-subject biological variation than IgG/IgG4 clearance ratio, allowing more accurate classification into normal and reduced charge selectivity. With our method, the lower 2.5% reference intervals for isoamylase clearance ratio were 1.1 in men and 1.9 in women.

  14. Screening for congenital cytomegalovirus infection using newborn urine samples collected on filter paper: feasibility and outcomes from a multicentre study.

    PubMed

    Koyano, Shin; Inoue, Naoki; Oka, Akira; Moriuchi, Hiroyuki; Asano, Kimisato; Ito, Yushi; Yamada, Hideto; Yoshikawa, Tetsushi; Suzutani, Tatsuo

    2011-01-01

    Background As congenital cytomegalovirus (CMV) infection causes significant clinical consequences not only at birth but also later as neurological sequelae, it is critical to establish a strategy for screening congenitally infected newborns. Previous studies have identified an insufficient sensitivity in screening methods based on the use of dried blood spots (DBSs). Objectives To evaluate the feasibility of the authors' recently developed method for large-scale screening for congenital CMV infection and to identify risk factors for congenital infection. Methods More than 21 000 newborns were enrolled at 25 sites in six geographically separate areas of Japan. Urine was collected onto filter cards placed in the diapers, which were then analysed by quantitative PCR using the filter disc directly as a template. Clinical and physical findings of the newborns were extracted from their medical records. CMV strains from the cases and their siblings were genetically compared. Viral loads in DBSs obtained from some of the cases were compared with those in the urine filters. Results Congenital CMV infection was identified in 0.31% (95% CI 0.24% to 0.39%) of the newborns, and 30% of the cases (20/66) had typical clinical manifestations and/or showed abnormalities in brain images at birth. Although the positive predictive value of our screening was 94%, the lack of any comparison with a gold standard assay prevented calculation of the negative predictive value. Almost two-thirds of the cases had siblings, a significantly higher frequency than for uninfected newborns. Most of the cases (21/25) excreted CMV strains identical to those of their siblings. CMV DNA was undetectable in three out of 12 retrievable DBS specimens. Conclusions Implementation of an effective large-scale screening programme for congenital CMV infection is feasible. Siblings are the major risk factor for congenital CMV infection, which emphasises the need for education of mothers-to-be as well as vaccine

  15. Comparison of gastric body and antral pH: a 24 hour ambulatory study in healthy volunteers.

    PubMed

    McLauchlan, G; Fullarton, G M; Crean, G P; McColl, K E

    1989-05-01

    Simultaneous ambulatory records of gastric antral and body pH were made over 24 hours in nine healthy volunteers by means of endoscopically positioned and anchored glass electrodes. Intragastric pH was temporarily raised after the endoscopy with the median pH value 30 minutes after the procedure being 3.9 (range 1.5-7.0) for the antrum and 4.1 (range 1.5-7.0) for the body. Daytime pH (median pH value between 12 00 h and 23 00 h) was lower in the antrum (median = 1.9, range 1.6-2.6) than in the body (median = 2.7, range 1.8-4.5) (p less than 0.05) and this was because of the rise in pH on eating being less marked in the antrum than in the body. The median peak pH recorded during the evening meal was only 4.1 (range 2.4-6.2) in the antrum compared with 6.3 (range 4.4-6.7) in the body (p less than 0.01). Preprandial pH (median value over the hour prior to the evening meal) was similar in the antrum (median = 1.9, range 1.2-2.5) and body (median = 1.9, range 1.3-2.8). Night-time pH (median pH value between 23 00 h and 05 00 h) in six subjects remained low and was similar in the antrum (median = 1.4, range 1.2-1.7) and body (median = 1.3, range 1.1-1.7). In two subjects, however, there were episodes of raised night-time pH which were more marked in the antrum than in the body. Antral biopsies showed gastritis in four of the nine normal volunteers, which in three was associated with the presence of campylobacter-like organisms. This study shows the significant regional variations in day and night-time intragastric pH.

  16. Perfusion-CT - Can We Predict Acute Pancreatitis Outcome within the First 24 Hours from the Onset of Symptoms?

    PubMed Central

    Pieńkowska, Joanna; Gwoździewicz, Katarzyna; Skrobisz-Balandowska, Katarzyna; Marek, Iwona; Kostro, Justyna; Szurowska, Edyta; Studniarek, Michał

    2016-01-01

    Purpose Severe acute pancreatitis (AP) is still a significant clinical problem which is associated with a highly mortality. The aim of this study was the evaluation of prognostic value of CT regional perfusion measurement performed on the first day of onset of symptoms of AP, in assessing the risk of developing severe form of acute pancreatitis. Material and Methods 79 patients with clinical symptoms and biochemical criteria indicative of acute pancreatitis (acute upper abdominal pain, elevated levels of serum amylase and lipase) underwent perfusion CT within 24 hours after onset of symptoms. The follow-up examinations were performed after 4–6 days to detect progression of the disease. Perfusion parameters were compared in 41 people who developed severe form of AP (pancreatic and/or peripancreatic tissue necrosis) with parameters in 38 consecutive patients in whom course of AP was mild. Blood flow, blood volume, mean transit time and permeability surface area product were calculated in the three anatomic pancreatic subdivisions (head, body and tail). At the same time the patient's clinical status was assessed by APACHE II score and laboratory parameters such as CRP, serum lipase and amylase, AST, ALT, GGT, ALP and bilirubin were compared. Results Statistical differences in the perfusion parameters between the group of patients with mild and severe AP were shown. Blood flow, blood volume and mean transit time were significantly lower and permeability surface area product was significantly higher in patients who develop severe acute pancreatitis and presence of pancreatic and/or peripancreatic necrosis due to pancreatic ischemia. There were no statistically significant differences between the two groups in terms of evaluated on admission severity of pancreatitis assessed using APACHE II score and laboratory tests. Conclusions CT perfusion is a very useful indicator for prediction and selection patients in early stages of acute pancreatitis who are at risk of

  17. Urine culture

    MedlinePlus

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  18. A test of the hypothesis that the collecting duct calcium-sensing receptor limits rise of urine calcium molarity in hypercalciuric calcium kidney stone formers.

    PubMed

    Bergsland, Kristin J; Coe, Fredric L; Gillen, Daniel L; Worcester, Elaine M

    2009-10-01

    The process of kidney stone formation depends on an imbalance between excretion of water and insoluble stone-forming salts, leading to high concentrations that supersaturate urine and inner medullary collecting duct (IMCD) fluid. For common calcium-containing stones, a critical mechanism that has been proposed for integrating water and calcium salt excretions is activation of the cell surface calcium-sensing receptor (CaSR) on the apical membranes of IMCD cells. High deliveries of calcium into the IMCD would be predicted to activate CaSR, leading to reduced membrane abundance of aquaporin-2, thereby limiting water conservation and protecting against stone formation. We have tested this hypothesis in 16 idiopathic hypercalciuric calcium stone formers and 14 matched normal men and women in the General Clinical Research Center. Subjects were fed identical diets; we collected 14 urine samples at 1-h intervals during a single study day, and one sample overnight. Hypercalciuria did not increase urine volume, so urine calcium molarity and supersaturation with respect to calcium oxalate and calcium phosphate rose proportionately to calcium excretion. Thus CaSR modulation of urine volume via IMCD CaSR activation does not appear to be an important mechanism of protection against stone formation. The overnight period, one of maximal water conservation, was a time of maximal stone risk and perhaps a target of specific clinical intervention.

  19. Identifying nutrients that are under-reported by an automated 24-hour dietary recall method in overweight and obese women after weight loss

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Underreporting of energy intake by 15-50% is a common problem in dietary assessment. Evidence suggests overweight/obese respondents are more likely to under-report than normal weight. This study compared Automated Self-Administered 24-hour recall (ASA24)-reported dietary intake to true intake in ove...

  20. The Automated Self-Administered 24-hour dietary recall (ASA24): A resource for researchers, clinicians, and educators from the National Cancer Institute

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Extensive evidence has demonstrated that 24-hour dietary recalls (24HDRs) provide high-quality dietary intake data with minimal bias, making them the preferred tool for monitoring the diets of populations and, increasingly, for studying diet and disease associations. Traditional 24HDRs, however, are...

  1. Heart rate variability parameters of myxomatous mitral valve disease in dogs with and without heart failure obtained using 24-hour Holter electrocardiography.

    PubMed

    Oliveira, M S; Muzzi, R A L; Araújo, R B; Muzzi, L A L; Ferreira, D F; Nogueira, R; Silva, E F

    2012-06-16

    Time-domain heart rate variability (HRV) parameters and the correlation between echocardiography and Holter examinations in dogs with myxomatous mitral valve disease (MMVD) were determined. Holter examination was also performed at different time frames: an entire 24-hour period, a four-hour period during sleep, and a four-hour period while awake. Ten healthy (control group) and 28 MMVD dogs, 15 with and 13 without heart failure, were evaluated. The SDANN (sd of the mean normal RR intervals for all five-minute segments during 24-hour Holter) and pNN(50) (percentage of differences between adjacent normal RR intervals that are >50 ms computed over 24-hour Holter) variables were significantly lower in the dogs with MMVD heart failure. The differences in HRV between the groups were only detected during the 24-hour evaluation period (P<0.05). There were high correlations (canonical analysis) between Holter and echocardiography examinations when considering pNN(50), SDANN, and LA/AO (left atrial to aortic root ratio) (r=0.92; P<0.05), indicating that both are important in evaluating MMVD dogs. SDANN and pNN(50) are measures of parasympathetic control of the heart, and thus, it is possible to infer that the MMVD dogs exhibit parasympathetic withdrawal during the development of heart failure.

  2. Validation of the automated self-administered 24-hour dietary recall for children (ASA24-Kids) among 9- to 11-year-old youth

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Our purpose was to validate ASA24-Kids-2012, a self-administered web-based 24-hour dietary recall (24hDR) among 9- to 11-year-old children. Sixty-nine children in two sites participated in the study. In one site, trained staff observed and recorded types and portions of foods and drinks consumed by ...

  3. Ambulatory 24 hour intraoesophageal pH and pressure recordings v provocation tests in the diagnosis of chest pain of oesophageal origin.

    PubMed Central

    Ghillebert, G; Janssens, J; Vantrappen, G; Nevens, F; Piessens, J

    1990-01-01

    Fifty patients with non-cardiac chest pain underwent 24 hour intraoesophageal pH and pressure recording and provocation tests to determine the relative value of both techniques in establishing the oesophageal origin of the chest pain. Twenty six patients (52%) had at least one positive provocation test: the acid perfusion test was positive related in 18 patients (36%), the edrophonium test in 16 patients (32%), the vasopressin test in five patients (10%), and the balloon distension test (performed in only 20 patients) in one (5%). The 24 hour pH and pressure recording correlated spontaneous chest pain attacks with abnormal motility or gastro-oesophageal reflux in 19 patients (38%). Fourteen of these patients also had at least one positive provocation test. Therefore, 24 hour pH and pressure recordings are only slightly better than a set of provocation tests in identifying the oesophagus as the cause of chest pain (10% diagnostic gain). In the case of oesophageal chest pain, however, 24 hour recording appeared to be the only way to identify the nature of the underlying oesophageal abnormality that caused the spontaneous pain attacks--for example, gastro-oesophageal reflux, motility disorders, or irritability of the oesophagus. PMID:2370009

  4. The effect of low level radiofrequency electromagnetic radiation on the excretion rates of stress hormones in operators during 24-hour shifts.

    PubMed

    Vangelova, K; Israel, M; Mihaylov, S

    2002-06-01

    The aim of the study was to investigate the effect of long term exposure to low level radiofrequency (RF) electromagnetic (EM) radiation on the excretion rates of stress hormones in satellite station operators during 24-hour shifts. Twelve male operators at a satellite station for TV communications and space research were studied during 24-hour shifts. Dosimetric evaluation of the exposure was carried out and showed low level exposure with specific absorption of 0.1127 J.kg-1. A control group of 12 unexposed male operators with similar job task and the same shift system were studied, too. The 11-oxycorticosteroids (11-OCS), adrenaline and noradrenaline were followed by spectrofluorimetric methods on 3-hour intervals during the 24-hour shifts. The data were analyzed by tests for interindividual analysis, Cosinor analysis and analysis of variance (ANOVA). Significant increase in the 24-hour excretion of 11-OCS and disorders in its circadian rhythm, manifested by increase in the mesor, decrease in the amplitude and shift in the acrophase were found in the exposed operators. The changes in the excretion rates of the catecholamines were significant and showed greater variability of both variables. The long term effect of the exposure to low-level RF EM radiation evoked pronounced stress reaction with changes in the circadian rhythm of 11-OCS and increased variability of catecholamines secretion. The possible health hazards associated with observed alteration in the stress system need to be clarified by identification of their significance and prognostic relevance.

  5. Characterization of pulmonary protein profiles in response to zinc oxide nanoparticles in mice: a 24-hour and 28-day follow-up study.

    PubMed

    Pan, Chih-Hong; Chuang, Kai-Jen; Chen, Jen-Kun; Hsiao, Ta-Chih; Lai, Ching-Huang; Jones, Tim P; BéruBé, Kelly A; Hong, Gui-Bing; Ho, Kin-Fai; Chuang, Hsiao-Chi

    2015-01-01

    Although zinc oxide nanoparticles (ZnONPs) are recognized to cause systemic disorders, little is known about the mechanisms that underlie the time-dependent differences that occur after exposure. The objective of this study was to investigate the mechanistic differences at 24 hours and 28 days after the exposure of BALB/c mice to ZnONPs via intratracheal instillation. An isobaric tag for the relative and absolute quantitation coupled with liquid chromatography/tandem mass spectrometry was used to identify the differential protein expression, biological processes, molecular functions, and pathways. A total of 18 and 14 proteins displayed significant changes in the lung tissues at 24 hours and 28 days after exposure, respectively, with the most striking changes being observed for S100-A9 protein. Metabolic processes and catalytic activity were the main biological processes and molecular functions, respectively, in the responses at the 24-hour and 28-day follow-up times. The glycolysis/gluconeogenesis pathway was continuously downregulated from 24 hours to 28 days, whereas detoxification pathways were activated at the 28-day time-point after exposure. A comprehensive understanding of the potential time-dependent effects of exposure to ZnONPs was provided, which highlights the metabolic mechanisms that may be important in the responses to ZnONP. PMID:26251593

  6. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBONPAK X SOLID ADSORBENT WITH THEMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDIES

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hours onto the graphitic adsorbent Carbopack X contained in a stainless steel tube badge (6.3 mm OD, 5 mm ID, and 90 mm in length) with analysis by thermal desorption/GC/MS has been evaluated in controlled tests. A test matrix of 42 tr...

  7. Investigation of cattle methane production and emission over a 24-hour period using measurements of δ13C and δD of emitted CH4 and rumen water

    NASA Astrophysics Data System (ADS)

    Bilek, R. S.; Tyler, S. C.; Kurihara, M.; Yagi, K.

    2001-07-01

    We have conducted a series of experiments to determine the effects different diets, including the addition of unsaturated fatty acids, had on isotopic signatures of CH4 emissions from dairy cattle. Measurements of emitted δ13CH4, δ13CO2, and δD-CH4 were made on gases collected over a 24-hour period from animal chambers containing individual Holstein cows. Some measurements of δD-H2O from samples collected directly from the rumen were also made. We observed variation in δ13CH4 values with time after feeding and a correlation in δ13C between emitted gases and diet. The average δ13CH4 value, which includes all samples of emitted gases, was -70.6±4.9‰ (n = 57). Measurements of δD-CH4 over the 24-hour sampling period had an average value of -357.8±15.0‰ (n = 56). These δD measurements are among the lightest reported for CH4 produced by cattle. Our cattle data indicate that hydrogen incorporated into the CH4 produced by CO2 reduction in high H2 concentration environments is fractionated to a greater degree than that incorporated in systems with relatively low H2 conditions, such as wetlands. Our results support bacterial studies that have demonstrated large hydrogen fractionation in high H2 concentration systems during methanogenesis.

  8. Unambiguous identification of thiouracil residue in urine collected in non-treated bovine by tandem and high-resolution mass spectrometry.

    PubMed

    Pinel, Gaud; Maume, Daniel; Deceuninck, Yoann; Andre, François; Le Bizec, Bruno

    2006-01-01

    Thyrostats are banned compounds in Europe since 1981 (directive 81/602/EC) because of their carcinogenic and teratogenic properties. However, the occurrence of thiouracil (TU) in bovine urines from national monitoring plans with quantifications in the range 1-10 microg . L(-1) occasionally raises the question of its origin which might either be the consequence of an illegal administration or the result of 'endogenous' production. In order to definitively and unambiguously identify the so-called thiouracil signal in non-treated bovine urines, independent mass spectrometry (MS) approaches have been used. Different reagents (3-IBBr, 3-BrBBr and PFBBr) were used to derivatise and to extract TU from urine samples and characterisation of the residues was performed by means of different MS approaches [LC/(ESI-)MS/MS, GC/(EI+)MS/MS and HRMS (EI and NCI)]. These combined strategies allowed for an independent and confident identification of TU in bovine urine samples collected from animals never treated with any thyrostatic drugs. This result is of prime importance for laboratories and risk managers involved in the field of forbidden growth promoters control: detection of TU residue in bovine urine will have to be carefully considered as a non-systematic proof of illegal administration.

  9. Analysis of correlation between 24-hour urinary sodium and the degree of blood pressure control in patients with chronic kidney disease and non-chronic kidney disease.

    PubMed

    Koo, Ho Seok; Kim, Yong Chul; Ahn, Shin Young; Oh, Se Won; Kim, Suhnggwon; Chin, Ho Jun

    2014-09-01

    We investigated the association between 24-hr urinary sodium (24UNA) and adequacy of blood pressure (BP) control in patients with chronic kidney disease (CKD) and nonCKD. All data were collected retrospectively by accessing the electrical medical records in patients with 24-hr urine collection and serum creatinine. Enrolled 400 subjects were subgrouped by the amount of 24UNA, or CKD stage. The appropriate BP was defined as BP < 130/80 mmHg for subjects with proteinuria, and BP < 140/90 mmHg for subjects without proteinuria. The mean level of 24UNA was 166±76 mEq/day. The 24UNA group was an independently related factor to diastolic BP as a continuous variable. The rate of appropriate BP control in patients with proteinuria was highest in 24UNA <100 mEq/L (P=0.012). The odds to fail achievement of BP target in subjects with 24UNA≥90 mEq/day was 2.441 (1.249-4.772, P=0.009) higher than that of 24UNA <90 mEq/day among participants with proteinuria. There was difference in the amount of 24UNA between CKD and non-CKD except each stage of CKD group. In conclusion, salt intake estimated by 24-hr urine sodium excretion is a risk factor to achieve appropriate BP control.

  10. Estimation of sodium and potassium intakes assessed by two 24 h urine collections in healthy Japanese adults: a nationwide study.

    PubMed

    Asakura, Keiko; Uechi, Ken; Sasaki, Yuki; Masayasu, Shizuko; Sasaki, Satoshi

    2014-10-14

    Excess Na intake and insufficient K intake are well-known risk factors for CVD. International comparative studies have reported that Japan has the highest intake of Na and the lowest intake of K in the world. However, no recent study has precisely assessed Na and K intakes in Japanese adults. In the present study, Na and K intakes were estimated from two 24 h urine collections implemented in twenty-three out of forty-seven prefectures in Japan. Apparently healthy men (n 384) and women (n 376), aged 20 to 69 years, who had been working in welfare facilities were recruited, with data collection conducted in February and March 2013. The mean Na excretion was 206·0 mmol/d in men and 173·9 mmol/d in women. The respective values of K excretion were 51·6 and 47·2 mmol/d. The excretion of both Na and K varied considerably among the prefectures, and was higher in subjects with a higher BMI. In contrast, only K excretion was associated with age. After estimating the usual intakes of Na and K, it was found that none of the male subjects met the recommended Na intake values of the WHO, and that only 3·2 % met those of the Japanese government. The respective values for females were 0·1 and 5·0 %. For K intake, 7·5 % of the total subjects met the recommended values of the WHO and 21·7 % met those of the Japanese government. These findings suggest that there is an urgent need for the development of an effective intervention programme to reduce Na intake and promote K intake in the Japanese population.

  11. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate

  12. COMPARISON OF TWO α2-ADRENERGIC AGONISTS ON URINE CONTAMINATION OF SEMEN COLLECTED BY ELECTROEJACULATION IN CAPTIVE AND SEMI-FREE-RANGING CHEETAH (ACINONYX JUBATUS).

    PubMed

    Marrow, Judilee C; Woc-Colburn, Margarita; Hayek, Lee-Ann C; Marker, Laurie; Murray, Suzan

    2015-06-01

    Alpha2-adrenergic agonists are used to immobilize many veterinary species, but use has been infrequently linked to urine contamination of semen collected via electroejaculation. The objective of the study was to compare the α2-agonists medetomidine and dexmedetomidine on urine contamination of semen in anesthetized cheetahs (Acinonyx jubatus) during electroejaculation procedures. From 2009-2012, a retrospective medical record review revealed 21 anesthesia events in 12 adult male cheetahs. Animals were immobilized with combinations of Telazol® (2.33±0.43 mg/kg) and ketamine (2.38±1 mg/kg); Telazol (1.17±0.14 mg/kg), ketamine (1.17±0.14 mg/kg), and medetomidine (0.012±0.0017 mg/kg); or Telazol (1.59±0.1 mg/kg), ketamine (1.59±0.1 mg/kg) and dexmedetomidine (0.01±0.001 mg/kg). Semen was successfully collected in all animals; four animals anesthetized with medetomidine had urine contamination (P=0.037). Medetomidine may contribute to urine contamination; however, further investigation is needed to determine significance in cheetahs.

  13. Urine drug screen

    MedlinePlus

    ... placed in a room where you have no access to your personal items or water. This is so you cannot dilute the sample, or use someone else's urine for the test. This test involves collecting a "clean-catch" (midstream) urine sample: Wash your hands with ...

  14. Filtration Device for On-Site Collection, Storage and Shipment of Cells from Urine and Its Application to DNA-Based Detection of Bladder Cancer

    PubMed Central

    Andersson, Elin; Dahmcke, Christina M.; Steven, Kenneth; Larsen, Louise K.; Guldberg, Per

    2015-01-01

    Molecular analysis of cells from urine provides a convenient approach to non-invasive detection of bladder cancer. The practical use of urinary cell-based tests is often hampered by difficulties in handling and analyzing large sample volumes, the need for rapid sample processing to avoid degradation of cellular content, and low sensitivity due to a high background of normal cells. We present a filtration device, designed for home or point-of-care use, which enables collection, storage and shipment of urinary cells. A special feature of this device is a removable cartridge housing a membrane filter, which after filtration of urine can be transferred to a storage unit containing an appropriate preserving solution. In spiking experiments, the use of this device provided efficient recovery of bladder cancer cells with elimination of >99% of excess smaller-sized cells. The performance of the device was further evaluated by DNA-based analysis of urinary cells collected from 57 patients subjected to transurethral resection following flexible cystoscopy indicating the presence of a tumor. All samples were tested for FGFR3 mutations and seven DNA methylation markers (BCL2, CCNA1, EOMES, HOXA9, POU4F2, SALL3 and VIM). In the group of patients where a transitional cell tumor was confirmed at histopathological evaluation, urine DNA was positive for one or more markers in 29 out of 31 cases (94%), including 19 with FGFR3 mutation (61%). In the group of patients with benign histopathology, urine DNA was positive for methylation markers in 13 out of 26 cases (50%). Only one patient in this group was positive for a FGFR3 mutation. This patient had a stage Ta tumor resected 6 months later. The ability to easily collect, store and ship diagnostic cells from urine using the presented device may facilitate non-invasive testing for bladder cancer. PMID:26151138

  15. Filtration Device for On-Site Collection, Storage and Shipment of Cells from Urine and Its Application to DNA-Based Detection of Bladder Cancer.

    PubMed

    Andersson, Elin; Dahmcke, Christina M; Steven, Kenneth; Larsen, Louise K; Guldberg, Per

    2015-01-01

    Molecular analysis of cells from urine provides a convenient approach to non-invasive detection of bladder cancer. The practical use of urinary cell-based tests is often hampered by difficulties in handling and analyzing large sample volumes, the need for rapid sample processing to avoid degradation of cellular content, and low sensitivity due to a high background of normal cells. We present a filtration device, designed for home or point-of-care use, which enables collection, storage and shipment of urinary cells. A special feature of this device is a removable cartridge housing a membrane filter, which after filtration of urine can be transferred to a storage unit containing an appropriate preserving solution. In spiking experiments, the use of this device provided efficient recovery of bladder cancer cells with elimination of >99% of excess smaller-sized cells. The performance of the device was further evaluated by DNA-based analysis of urinary cells collected from 57 patients subjected to transurethral resection following flexible cystoscopy indicating the presence of a tumor. All samples were tested for FGFR3 mutations and seven DNA methylation markers (BCL2, CCNA1, EOMES, HOXA9, POU4F2, SALL3 and VIM). In the group of patients where a transitional cell tumor was confirmed at histopathological evaluation, urine DNA was positive for one or more markers in 29 out of 31 cases (94%), including 19 with FGFR3 mutation (61%). In the group of patients with benign histopathology, urine DNA was positive for methylation markers in 13 out of 26 cases (50%). Only one patient in this group was positive for a FGFR3 mutation. This patient had a stage Ta tumor resected 6 months later. The ability to easily collect, store and ship diagnostic cells from urine using the presented device may facilitate non-invasive testing for bladder cancer.

  16. Reductions in Mean 24-Hour Ambulatory Blood Pressure After 6-Week Treatment With Canagliflozin in Patients With Type 2 Diabetes Mellitus and Hypertension.

    PubMed

    Townsend, Raymond R; Machin, Israel; Ren, Jimmy; Trujillo, Angelina; Kawaguchi, Masato; Vijapurkar, Ujjwala; Damaraju, Chandrasekharrao V; Pfeifer, Michael

    2016-01-01

    This randomized, double-blind, placebo-controlled study evaluated the early effects of canagliflozin on blood pressure (BP) in patients with type 2 diabetes mellitus (T2DM) and hypertension. Patients were randomized to canagliflozin 300 mg, canagliflozin 100 mg, or placebo for 6 weeks and underwent 24-hour ambulatory BP monitoring before randomization, on day 1 of treatment, and after 6 weeks. The primary endpoint was change in mean 24-hour systolic BP (SBP) from baseline to week 6. Overall, 169 patients were included (mean age, 58.6 years; glycated hemoglobin, 8.1%; seated BP 138.5/82.7 mm Hg). At week 6, canagliflozin 300 mg provided greater reductions in mean 24-hour SBP than placebo (least squares mean -6.2 vs -1.2 mm Hg, respectively; P=.006). Numerical reductions in SBP were observed with canagliflozin 100 mg. Canagliflozin was generally well tolerated, with side effects similar to those reported in previous studies. These results suggest that canagliflozin rapidly reduces BP in patients with T2DM and hypertension.

  17. Determination of parent and hydroxy PAHs in personal PM₂.₅ and urine samples collected during Native American fish smoking activities.

    PubMed

    Motorykin, Oleksii; Schrlau, Jill; Jia, Yuling; Harper, Barbara; Harris, Stuart; Harding, Anna; Stone, David; Kile, Molly; Sudakin, Daniel; Massey Simonich, Staci L

    2015-02-01

    A method was developed for the measurement of 19 parent PAHs (PAHs) and 34 hydroxylated PAHs (OH-PAHs) in urine and personal air samples of particulate matter less than 2.5 μm in diameter (PM₂.₅) using GC-MS and validated using NIST SRM 3672 (Organic Contaminants in Smoker's Urine) and SRM 3673 (Organic Contaminants in Nonsmoker's Urine). The method was used to measure PAHs and OH-PAHs in urine and personal PM₂.₅ samples collected from the operators of two different fish smoking facilities (tipi and smoke shed) burning two different wood types (alder and apple) on the Confederated Tribes of Umatilla Indian Reservation (CTUIR) while they smoked salmon. Urine samples were spiked with β-glucuronidase/arylsulfatase to hydrolyze the conjugates of OH-PAHs and the PAHs and OH-PAHs were extracted using Plexa and C18 solid phases, in series. The 34 OH-PAHs were derivatized using MTBSTFA, and the mixture was measured by GC-MS. The personal PM₂.₅ samples were extracted using pressurized liquid extraction, derivatized with MTBSTFA and analyzed by GC-MS for PAHs and OH-PAHs. Fourteen isotopically labeled surrogates were added to accurately quantify PAHs and OH-PAHs in the urine and PM₂.₅ samples and three isotopically labeled internal standards were used to calculate the recovery of the surrogates. Estimated detection limits in urine ranged from 6.0 to 181 pg/ml for OH-PAHs and from 3.0 to 90 pg/ml for PAHs, and, in PM₂.₅, they ranged from 5.2 to 155 pg/m(3) for OH-PAHs and from 2.5 to 77 pg/m(3) for PAHs. The results showed an increase in OH-PAH concentrations in urine after 6h of fish smoking and an increase in PAH concentrations in air within each smoking facility. In general, the PAH exposure in the smoke shed was higher than in the tipi and the PAH exposure from burning apple wood was higher than burning alder. PMID:25461072

  18. Determination of Parent and Hydroxy PAHs in Personal PM2.5 and Urine Samples Collected During Native American Fish Smoking Activities

    PubMed Central

    Motorykin, Oleksii; Schrlau, Jill; Jia, Yuling; Harper, Barbara; Harris, Stuart; Harding, Anna; Stone, David; Kile, Molly; Sudakin, Daniel; Massey Simonich, Staci L.

    2014-01-01

    A method was developed for the measurement of 19 parent PAHs (PAHs) and 34 hydroxylated PAHs (OH-PAHs) in urine and personal air samples of particulate matter less than 2.5 um in diameter (PM2.5) using GC-MS and validated using NIST SRM 3672 (Organic Contaminants in Smoker’s Urine) and SRM 3673 (Organic Contaminants in Nonsmoker’s Urine). The method was used to measure PAHs and OH-PAHs in urine and personal PM2.5 samples collected from the operators of two different fish smoking facilities (tipi and smoke shed) burning two different wood types (alder and apple) on the Confederated Tribes of Umatilla Indian Reservation (CTUIR) while they smoked salmon. Urine samples were spiked with β-glucuronidase/arylsulfatase to hydrolyze the conjugates of OH-PAHs and the PAHs and OH-PAHs were extracted using Plexa and C18 solid phases, in series. The 34OH-PAHs were derivatized using MTBSTFA, and the mixture was measured by GC-MS. The personal PM2.5samples were extracted using pressurized liquid extraction, derivatized with MTBSTFA and analyzed by GC-MS for PAHs and OH-PAHs. Fourteen isotopically labeled surrogates were added to accurately quantify PAHs and OH-PAHs in the urine and PM2.5 samples and three isotopically labeled internal standards were used to calculate the recovery of the surrogates. Estimated detection limits in urine ranged from 6.0 to 181 pg/ml for OH-PAHs and from 3.0 to 90 pg/ml for PAHs, and, in PM2.5, they ranged from 5.2 to 155 pg/m3 for OH-PAHs and from 2.5 to 77 pg/m3 for PAHs. The results showed an increase in OH-PAH concentrations in urine after 6 hours offish smoking and an increase in PAH concentrations in air within each smoking facility. In general, the PAH exposure in the smoke shed was higher than in the tipi and the PAH exposure from burning apple wood was higher than burning alder. PMID:25461072

  19. Relationship between salt consumption measured by 24-h urine collection and blood pressure in the adult population of Vitória (Brazil)

    PubMed Central

    Rodrigues, S.L.; Souza, P.R.; Pimentel, E.B.; Baldo, M.P.; Malta, D.C.; Mill, J.G.; Szwarcwald, C.L.

    2015-01-01

    High salt intake is related to an increase in blood pressure and development of hypertension. However, currently, there are no national representative data in Brazil using the gold standard method of 24-h urine collection to measure sodium consumption. This study aimed to determine salt intake based on 24-h urine collection in a sample of 272 adults of both genders and to correlate it with blood pressure levels. We used a rigorous protocol to assure an empty bladder prior to initiating urine collection. We excluded subjects with a urine volume <500 mL, collection period outside of an interval of 23-25 h, and subjects with creatinine excretion that was not within the range of 14.4-33.6 mg/kg (men) and 10.8-25.2 mg/kg (women). The mean salt intake was 10.4±4.1 g/day (d), and 94% of the participants (98% of men and 90% of women) ingested more than the recommended level of 5 g/d. We found a positive association between salt and body mass index (BMI) categories, as well as with salt and blood pressure, independent of age and BMI. The difference in systolic blood pressure reached 13 mmHg between subjects consuming less than 6 g/d of salt and those ingesting more than 18 g/d. Subjects with hypertension had a higher estimated salt intake than normotensive subjects (11.4±5.0 vs 9.8±3.6 g/d, P<0.01), regardless of whether they were under treatment. Our data indicate the need for interventions to reduce sodium intake, as well the need for ongoing, appropriate monitoring of salt consumption in the general population. PMID:26132095

  20. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion: The 2009-2011 Korea National Health and Nutrition Examination Survey.

    PubMed

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-03-01

    Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286-4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the abovementioned variables

  1. Factors Associated With High Sodium Intake Based on Estimated 24-Hour Urinary Sodium Excretion: The 2009-2011 Korea National Health and Nutrition Examination Survey.

    PubMed

    Hong, Jae Won; Noh, Jung Hyun; Kim, Dong-Jun

    2016-03-01

    Although reducing dietary salt consumption is the most cost-effective strategy for preventing progression of cardiovascular and renal disease, policy-based approaches to monitor sodium intake accurately and the understanding factors associated with excessive sodium intake for the improvement of public health are lacking. We investigated factors associated with high sodium intake based on the estimated 24-hour urinary sodium excretion, using data from the 2009 to 2011 Korea National Health and Nutrition Examination Survey (KNHANES). Among 21,199 adults (≥19 years of age) who participated in the 2009 to 2011 KNHANES, 18,000 participants (weighted n = 33,969,783) who completed urinary sodium and creatinine evaluations were analyzed in this study. The 24-hour urinary sodium excretion was estimated using Tanaka equation. The mean estimated 24-hour urinary sodium excretion level was 4349 (4286-4413) mg per day. Only 18.5% (weighted n = 6,298,481/3,396,973, unweighted n = 2898/18,000) of the study participants consumed less the 2000 mg sodium per day. Female gender (P < 0.001), older age (P < 0.001), total energy intake ≥50 percentile (P < 0.005), and obesity (P < 0.001) were associated with high sodium intake, even after adjusting for potential confounders. Senior high school/college graduation in education and managers/professionals in occupation were associated with lower sodium intake (P < 0.001). According to hypertension management status, those who had hypertension without medication consumed more sodium than those who were normotensive. However, those who receiving treatment for hypertension consumed less sodium than those who were normotensive (P < 0.001). The number of family members, household income, and alcohol drinking did not affect 24-hour urinary sodium excretion. The logistic regression analysis for the highest estimated 24-hour urinary sodium excretion quartile (>6033 mg/day) using the abovementioned variables

  2. Calcium - urine

    MedlinePlus

    High levels of urine calcium (above 300 mg/day) may be due to: Chronic kidney disease High vitamin D levels Leaking of calcium from the kidneys into the urine, which causes calcium kidney stones Sarcoidosis Taking ...

  3. Widespread occurrence of perchlorate in water, foodstuffs and human urine collected from Kuwait and its contribution to human exposure.

    PubMed

    Alomirah, Husam F; Al-Zenki, Sameer F; Alaswad, Marivi C; Alruwaih, Noor A; Wu, Qian; Kannan, Kurunthachalam

    2016-06-01

    Perchlorate is a thyroid hormone-disrupting compound and is reported to occur widely in the environment. Little is known on human exposure to perchlorate in Kuwait. In this study, 218 water samples, 618 commonly consumed foodstuffs and 532 urine samples collected from Kuwait were analysed to assess the exposure of the Kuwaiti population to perchlorate. For the estimation of daily intake of perchlorate, food consumption rates were obtained from the National Nutrition Survey in the State of Kuwait (NNSSK). The results showed that leafy vegetables accounted for a major share of perchlorate exposure among the Kuwaiti population at 0.062 µg kg(-)(1) bw day(-)(1) (36.2%), followed by fruits at 0.026 µg kg(-)(1) bw day(-)(1) (15.3%) and non-leafy vegetables at 0.017 µg kg(-)(1) bw day(-)(1) (10.1%). The urinary perchlorate geometric mean (GM) concentrations ranged from 8.51 to 17.1 µg l(-)(1) for the five age groups, which were higher than those reported in other countries. The estimated urinary perchlorate exposure for the Kuwaiti general population was 0.42 µg kg(-)(1) bw day(-)(1), which was higher than that reported for the United States. The dietary intake of perchlorate for the Kuwaiti population ranged from 0.14 to 0.67 µg kg(-)(1) bw day(-)(1) for the five age groups, with a mean total daily intake of 0.17 µg kg(-)(1) bw day(-)(1) for the general population. The highest estimated dietary mean daily intake of perchlorate (0.67 µg kg(-)(1) bw day(-)(1)) was found for children at 3-5 years. The estimated dietary perchlorate exposure in Kuwait is higher than the recommended mean reference dose (RfD) but lower than that of provisional maximum tolerable daily intake (PMTDI) set by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). PMID:27248576

  4. Widespread occurrence of perchlorate in water, foodstuffs and human urine collected from Kuwait and its contribution to human exposure.

    PubMed

    Alomirah, Husam F; Al-Zenki, Sameer F; Alaswad, Marivi C; Alruwaih, Noor A; Wu, Qian; Kannan, Kurunthachalam

    2016-06-01

    Perchlorate is a thyroid hormone-disrupting compound and is reported to occur widely in the environment. Little is known on human exposure to perchlorate in Kuwait. In this study, 218 water samples, 618 commonly consumed foodstuffs and 532 urine samples collected from Kuwait were analysed to assess the exposure of the Kuwaiti population to perchlorate. For the estimation of daily intake of perchlorate, food consumption rates were obtained from the National Nutrition Survey in the State of Kuwait (NNSSK). The results showed that leafy vegetables accounted for a major share of perchlorate exposure among the Kuwaiti population at 0.062 µg kg(-)(1) bw day(-)(1) (36.2%), followed by fruits at 0.026 µg kg(-)(1) bw day(-)(1) (15.3%) and non-leafy vegetables at 0.017 µg kg(-)(1) bw day(-)(1) (10.1%). The urinary perchlorate geometric mean (GM) concentrations ranged from 8.51 to 17.1 µg l(-)(1) for the five age groups, which were higher than those reported in other countries. The estimated urinary perchlorate exposure for the Kuwaiti general population was 0.42 µg kg(-)(1) bw day(-)(1), which was higher than that reported for the United States. The dietary intake of perchlorate for the Kuwaiti population ranged from 0.14 to 0.67 µg kg(-)(1) bw day(-)(1) for the five age groups, with a mean total daily intake of 0.17 µg kg(-)(1) bw day(-)(1) for the general population. The highest estimated dietary mean daily intake of perchlorate (0.67 µg kg(-)(1) bw day(-)(1)) was found for children at 3-5 years. The estimated dietary perchlorate exposure in Kuwait is higher than the recommended mean reference dose (RfD) but lower than that of provisional maximum tolerable daily intake (PMTDI) set by the Joint FAO/WHO Expert Committee on Food Additives (JECFA).

  5. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  6. Decreased striatal dopamine release underlies increased expression of long-term synaptic potentiation at corticostriatal synapses 24 hours after 3-nitropropionic acid induced chemical hypoxia

    PubMed Central

    Akopian, Garnik; Crawford, Cynthia; Beal, M. Flint; Cappelletti, Maurand; Jakowec, Michael W.; Petzinger, Giselle M.; Zheng, Ling; Gheorghe, Stacey L.; Reichel, Carmela M.; Chow, Robert; Walsh, John P

    2008-01-01

    The striatum is particularly sensitive to the irreversible inhibitor of succinate dehyrdrogenase 3-nitropropionic acid (3-NP). In the present study we examined early changes in behavior and dopamine and glutamate synaptic physiology created by a single systemic injection of 3-NP in Fischer 344 rats. Hind limb dystonia was seen 2 hours after 3-NP injections and rats performed poorly on balance beam and rota-rod motor tests 24 hours later. Systemic 3-NP increased NMDA receptor-dependent long-term potentiation (LTP) at corticostriatal synapses over the same time period. The 3-NP induced corticostriatal LTP was not due to increased NMDA receptor number or function, since 3-NP did not change MK-801 binding or NMDA/AMPA receptor current ratios. The LTP seen 24 hours after 3-NP was D1 receptor-dependent and reversed by exogenous addition of dopamine or a D2 receptor agonist to brain slices. High performance liquid chromatography and fast scan cyclic voltammetry revealed a decrease in dopamine content and release in rats injected 24 hours earlier with 3-NP, and much like the enhanced LTP, dopamine changes were reversed by 48 hours. Tyrosine hydroxylase expression was not changed and there was no evidence of striatal cell loss at 24–48 hours after 3-NP exposure. Sprague-Dawley rats showed similar physiological responses to systemic 3-NP, albeit with reduced sensitivity. Thus, 3-NP causes significant changes in motor behavior marked by parallel changes in striatal dopamine release and corticostriatal synaptic plasticity. PMID:18799690

  7. [The normalisation of blood sugar using a non-miniaturised artifical pancreas. Application for 24 hours in 7 insulin-dependent diabetics (author's transl)].

    PubMed

    Slama, G; Klein, J C; Tardieu, M C; Tchobroutsky, G

    1977-06-25

    Seven insulin-dependent diabetic were treated for 24 to 36 hours by intravenous injections of insulin adapted to variations in blood glucose using a fairly voluminous automatic regulation device. This artificial pancreas consists of a modified Technicon blood sugar apparatus which provides continuous estimation of blood glucose using non-haemolysed whole blood by a glucose oxidase method with an inertia time of 6 minutes, a table calculator and a newly developed interpretation and command electronic unit (GlucostatR). Normalisation of blood glucose was obtained for at least 24 hours, during and between meals, during a period following an oral glucose load and throughout the night.

  8. Italian society of hypertension guidelines for conventional and automated blood pressure measurement in the office, at home and over 24 hours.

    PubMed

    Parati, Gianfranco; Omboni, Stefano; Palatini, Paolo; Rizzoni, Damiano; Bilo, Grzegorz; Valentini, Mariaconsuelo; Rosei, Enrico Agabiti; Mancia, Giuseppe

    2008-10-01

    This article offers instructions and recommendations on how to perform blood pressure measurements in the doctor's office, in the patient's home and in ambulatory conditions over 24 hours. Great attention is paid to some of the general aspects of blood pressure measurement, including the accuracy of blood pressure measuring devices, the importance of a 'white-coat effect', and the need for patient education. This article also deals with a number of practical details, such as the importance of patient's relaxation and position, arm position and support, arm selection and cuff selection and application. Recommendations are provided on the observer's position and performance, and on the need to pay attention to specific factors affecting the blood pressure measurement in different patient populations, namely in children, elderly and obese people, pregnant women, patients with arrhythmias and patients on treatment. This article then separately focuses on the characteristics of auscultatory and automated measurements, the latter performed either in the office, at home or over 24 hours in ambulatory settings. Home blood pressure monitoring (HBPM) is becoming increasingly important in the diagnosis and management of arterial hypertension. The importance of HBPM in cardiovascular prevention, related to a deeper involvement of patients in their long-term management, and the wide diffusion of this approach in populations, is not always accompanied by adequate knowledge of how to make proper use of this technique, which emphasizes the need for more precise recommendations. This article summarizes the available evidence and provides recommendations on the use of home blood pressure monitoring in clinical practice and in research. It updates the previous recommendations on the same topic issued in 2000. The main topics addressed include the methodology of HBPM, focusing on measurement conditions and procedures, ranging from patient/subject position, to arm selection, arm

  9. Evaluation of the Bladder Stimulation Technique to Collect Midstream Urine in Infants in a Pediatric Emergency Department

    PubMed Central

    Tran, Antoine; Demonchy, Diane; Caci, Hervé; Desmontils, Jonathan; Montaudie-Dumas, Isabelle; Bensaïd, Ronny; Haas, Hervé; Berard, Etienne

    2016-01-01

    Objective Midstream clean-catch urine is an accepted method to diagnose urinary tract infection but is impracticable in infants before potty training. We tested the bladder stimulation technique to obtain a clean-catch urine sample in infants. Materials and methods We included 142 infants under walking age who required a urine sample in a cross- sectional study carried out during a 3-months period, from September to November 2014, in the emergency department of the University Children’s Hospital of Nice (France). A technique based on bladder stimulation and lumbar stimulation maneuvers, with at least two attempts, was tested by four trained physicians. The success rate and time to obtain urine sample within 3 minutes were evaluated. Discomfort (EVENDOL score ≥4/15) was measured. We estimated the risk factors in the failure of the technique. Chi-square test or Fisher’s exact test were used to compare frequencies. T-test and Wilcoxon test were used to compare quantitative data according to the normality of the distribution. Risk factors for failure of the technique were evaluated using a multivariate logistic regression model. Results We obtained midstream clean-catch urine in 55.6% of infants with a median time of 52.0 s (10.0; 110.0). The success rate decreased with age from 88.9% (newborn) to 28.6% (>1 y) (p = 0.0001) and with weight, from 85.7% (<4kg) to 28.6% (>10kg) (p = 0.0004). The success rate was 60.8% for infants without discomfort (p<0.0001). Heavy weight and discomfort were associated with failure, with adjusted ORs of 1.47 [1.04–2.31] and 6.65 [2.85–15.54], respectively. Conclusion Bladder stimulation seems to be efficient in obtaining midstream urine with a moderate success rate in our study sample. This could be an alternative technique for infants before potty training but further randomized multicenter studies are needed to validate this procedure. PMID:27031953

  10. Association between 24-Hour Urinary Cadmium and Pulmonary Function among Community-Exposed Men: The VA Normative Aging Study

    PubMed Central

    Lampe, Brad J.; Park, Sung Kyun; Robins, Thomas; Mukherjee, Bhramar; Litonjua, Augusto A.; Amarasiriwardena, Chitra; Weisskopf, Marc; Sparrow, David; Hu, Howard

    2008-01-01

    Background High levels of cadmium exposure are known to cause emphysema in occupationally exposed workers, but little has been reported to date on the association between chronic environmental cadmium exposure and pulmonary function. Objective In this study we examined the association between pulmonary function and cadmium body burden in a subcohort of the Normative Aging Study, a community-based study of aging. Methods We examined 96 men who had cadmium measured in single 24-hr urinary specimens collected in 1994–1995 and who had one to three tests of pulmonary function between 1994 and 2002 (a total of 222 observations). We used mixed-effect models to predict pulmonary function based on individual 24-hr urinary cadmium output, adjusted for age, height, time elapsed from the baseline, and smoking status. We assessed effect modification by smoking status. Results Among all subjects, a single log-unit increase in baseline urinary cadmium was inversely associated with forced expiratory volume in 1 sec (FEV1) percent predicted [β = −7.56%; 95% confidence interval (CI) −13.59% to −1.53%]; forced vital capacity (FVC) percent predicted (β = −2.70%; 95% CI −7.39% to 1.99%), and FEV1/FVC ratio (β = −4.13%; 95% CI −7.61% to −0.66%). In models including an interaction between urinary cadmium and smoking status, there was a graded, statistically significant reduction in FEV1/FVC ratio across smoking status in association with urinary cadmium. Conclusions This study suggests that chronic cadmium exposure is associated with reduced pulmonary function, and cigarette smoking modifies this association. These results should be interpreted with caution because the sample size is small, and further studies are needed to confirm our findings. PMID:18795167

  11. Successful Non-Surgical Deep Uterine Transfer of Porcine Morulae after 24 Hour Culture in a Chemically Defined Medium

    PubMed Central

    Martinez, Emilio A.; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25°C and 37°C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5°C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25°C but not at 37°C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37°C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37°C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0±0.6 and 9.4±0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs. PMID:25118944

  12. Successful non-surgical deep uterine transfer of porcine morulae after 24 hour culture in a chemically defined medium.

    PubMed

    Martinez, Emilio A; Angel, Miguel Angel; Cuello, Cristina; Sanchez-Osorio, Jonatan; Gomis, Jesus; Parrilla, Inmaculada; Vila, Jordi; Colina, Ignaci; Diaz, Marta; Reixach, Josep; Vazquez, Jose Luis; Vazquez, Juan Maria; Roca, Jordi; Gil, Maria Antonia

    2014-01-01

    Excellent fertility and prolificacy have been reported after non-surgical deep uterine transfers of fresh in vivo-derived porcine embryos. Unfortunately, when this technology is used with vitrified embryos, the reproductive performance of recipients is low. For this reason and because the embryos must be stored until they are transferred to the recipient farms, we evaluated the potential application of non-surgical deep uterine transfers with in vivo-derived morulae cultured for 24 h in liquid stage. In Experiment 1, two temperatures (25 °C and 37 °C) and two media (one fully defined and one semi-defined) were assessed. Morulae cultured in culture medium supplemented with bovine serum albumin and fetal calf serum at 38.5 °C in 5% CO2 in air were used as controls. Irrespective of medium, the embryo viability after 24 h of culture was negatively affected (P<0.05) at 25 °C but not at 37 °C compared with the controls. Embryo development was delayed in all experimental groups compared with the control group (P<0.001). Most of the embryos (95.7%) cultured at 37 °C achieved the full or expanded blastocyst stage, and unlike the controls, none of them hatched at the end of culture. In Experiment 2, 785 morulae were cultured in the defined medium at 37 °C for 24 h, and the resulting blastocysts were transferred to the recipients (n = 24). Uncultured embryos collected at the blastocyst stage (n = 750) were directly transferred to the recipients and used as controls (n = 25). No differences in farrowing rates (91.7% and 92.0%) or litter sizes (9.0 ± 0.6 and 9.4 ± 0.8) were observed between the groups. This study demonstrated, for the first time, that high reproductive performance can be achieved after non-surgical deep uterine transfers with short-term cultured morulae in a defined medium, which opens new possibilities for the sanitary, safe national and international trade of porcine embryos and the commercial use of embryo transfer in pigs.

  13. Liquid-containing Refluxes and Acid Refluxes May Be Less Frequent in the Japanese Population Than in Other Populations: Normal Values of 24-hour Esophageal Impedance and pH Monitoring

    PubMed Central

    Kawamura, Osamu; Kohata, Yukie; Kawami, Noriyuki; Iida, Hiroshi; Kawada, Akiyo; Hosaka, Hiroko; Shimoyama, Yasuyuki; Kuribayashi, Shiko; Fujiwara, Yasuhiro; Iwakiri, Katsuhiko; Inamori, Masahiko; Kusano, Motoyasu; Hongo, Micho

    2016-01-01

    Background/Aims Twenty-four-hour esophageal impedance and pH monitoring allows detection of all types of reflux episodes and is considered the best technique for identifying gastroesophageal refluxes. However, normative data for the Japanese population are lacking. This multicenter study aimed to establish the normal range of 24-hour esophageal impedance and pH data both in the distal and the proximal esophagus in Japanese subjects. Methods Forty-two healthy volunteers (25 men and 17 women) with a mean ± standard deviation age of 33.3 ± 12.4 years (range: 22–72 years) underwent a combined 24-hour esophageal impedance and pH monitoring. According to the physical and pH properties, distal or proximal esophageal reflux events were categorized. Results Median 45 reflux events occurred in 24 hours, and the 95th percentile was 85 events. Unlike previous reports, liquid-containing reflux events are median 25/24 hours with the 95th percentile of 62/24 hours. Acidic reflux events were median 11/24 hours with the 95th percentile of 39/24 hours. Non-acidic gas reflux events were median 15/24 hours with the 95th percentile of 39/24 hours. Proximal reflux events accounted for 80% of the total reflux events and were mainly non-acidic gas refluxes. About 19% of liquid and mixed refluxes reached the proximal esophagus. Conclusions Unlike previous studies, liquid-containing and acidic reflux events may be less frequent in the Japanese population. Non-acidic gas reflux events may be frequent and a cause of frequent proximal reflux events. This study provides important normative data for 24-hour impedance and pH monitoring in both the distal and the proximal esophagus in the Japanese population. PMID:27247103

  14. Treatment of burns in the first 24 hours: simple and practical guide by answering 10 questions in a step-by-step form

    PubMed Central

    2012-01-01

    Residents in training, medical students and other staff in surgical sector, emergency room (ER) and intensive care unit (ICU) or Burn Unit face a multitude of questions regarding burn care. Treatment of burns is not always straightforward. Furthermore, National and International guidelines differ from one region to another. On one hand, it is important to understand pathophysiology, classification of burns, surgical treatment, and the latest updates in burn science. On the other hand, the clinical situation for treating these cases needs clear guidelines to cover every single aspect during the treatment procedure. Thus, 10 questions have been organised and discussed in a step-by-step form in order to achieve the excellence of education and the optimal treatment of burn injuries in the first 24 hours. These 10 questions will clearly discuss referral criteria to the burn unit, primary and secondary survey, estimation of the total burned surface area (%TBSA) and the degree of burns as well as resuscitation process, routine interventions, laboratory tests, indications of Bronchoscopy and special considerations for Inhalation trauma, immediate consultations and referrals, emergency surgery and admission orders. Understanding and answering the 10 questions will not only cover the management process of Burns during the first 24 hours but also seems to be an interactive clear guide for education purpose. PMID:22583548

  15. Estimation of 24-hour thyroid uptake of I-131 sodium iodide using a 5-minute uptake of technetium-99m pertechnetate

    SciTech Connect

    Smith, J.J.; Croft, B.Y.; Brookeman, V.A.; Teates, C.D. )

    1990-02-01

    The authors have developed a method to estimate the 24-hour sodium iodide thyroid uptake based on a 5-minute Tc-99m pertechnetate thyroid uptake using the equation: Estimated Iodide Uptake = 17.72*In(Pertechnetate Uptake) + 30.40. This estimation has a correlation coefficient of 0.90. It is based on a data pool of 44 patients who underwent I-131 and Tc-99m studies within 2 weeks of each other from 1978-1988, with established diagnoses as follows: 12 euthyroid, 6 hyperthyroid with multinodular goiters, 15 hyperthyroid with diffuse goiters, 4 with subacute thyroiditis, and 7 unknown. The population consisted of 30 women and 14 men with a mean age of 52.0 +/- 17.5 years; this sample was screened for use of thyroid hormone, propylthiouracil, and radiographic contrast. The authors believe this estimation method is of value whenever a 24-hour iodide uptake is desired, and where speed and minimizing radiation dose are factors. This method is strongly recommended for thyroid uptake evaluation before I-131 therapy.

  16. Self-Perception of Swallowing-Related Problems in Laryngopharyngeal Reflux Patients Diagnosed with 24-Hour Oropharyngeal pH Monitoring

    PubMed Central

    Mesallam, Tamer A.; Farahat, Mohamed

    2016-01-01

    Background and Objectives. Swallowing difficulty is considered one of the nonspecific symptoms that many patients with laryngopharyngeal reflux complain of. However, the relationship between laryngopharyngeal reflux and swallowing problems is not clear. The purpose of this work is to explore correlation between swallowing-related problems and laryngopharyngeal reflux (LPR) in a group of patients diagnosed with oropharyngeal pH monitoring and to study the effect of laryngopharyngeal reflux on the patients' self-perception of swallowing problems. Methods. 44 patients complaining of reflux-related problems were included in the study. Patients underwent 24-hour oropharyngeal pH monitoring and were divided into positive and negative LPR groups based on the pH monitoring results. All patient filled out the Dysphagia Handicap Index (DHI) and Reflux Symptom Index (RSI) questionnaires. Comparison was made between the positive and negative LPR groups regarding the results of the DHI and RSI ratings. Also, correlation between DHI scores, RSI scores, and pH monitoring results was studied. Results. Significant difference was reported between positive and negative LPR groups regarding DHI scores, RSI scores, and overall rating of swallowing difficulty. There was significant correlation demonstrated between DHI scores, RSI scores, and 24-hour oropharyngeal pH results. Conclusion. Laryngopharyngeal reflux appears to have a significant impact on patients' self-perception of swallowing problems as measured by DHI. PMID:26966689

  17. Prognostic factors for death and survival with or without complications in cardiac arrest patients receiving CPR within 24 hours of anesthesia for emergency surgery

    PubMed Central

    Siriphuwanun, Visith; Punjasawadwong, Yodying; Lapisatepun, Worawut; Charuluxananan, Somrat; Uerpairojkit, Ketchada

    2014-01-01

    Purpose To determine prognostic factors for death and survival with or without complications in cardiac arrest patients who received cardiopulmonary resuscitation (CPR) within 24 hours of receiving anesthesia for emergency surgery. Patients and methods A retrospective cohort study approved by the Maharaj Nakorn Chiang Mai University Hospital Ethical Committee. Data used were taken from records of 751 cardiac arrest patients who received their first CPR within 24 hours of anesthesia for emergency surgery between January 1, 2003 and October 31, 2011. The reviewed data included patient characteristics, surgical procedures, American Society of Anesthesiologist (ASA) physical status classification, anesthesia information, the timing of cardiac arrest, CPR details, and outcomes at 24 hours after CPR. Univariate and polytomous logistic regression analyses were used to determine prognostic factors associated with the outcome variable. P-values of less than 0.05 were considered statistically significant. Results The outcomes at 24 hours were death (638/751, 85.0%), survival with complications (73/751, 9.7%), and survival without complications (40/751, 5.3%). The prognostic factors associated with death were: age between 13–34 years (OR =3.08, 95% CI =1.03–9.19); ASA physical status three and higher (OR =6.60, 95% CI =2.17–20.13); precardiopulmonary comorbidity (OR =3.28, 95% CI =1.09–9.90); the condition of patients who were on mechanical ventilation prior to receiving anesthesia (OR =4.11, 95% CI =1.17–14.38); surgery in the upper abdominal site (OR =14.64, 95% CI =2.83–75.82); shock prior to cardiac arrest (OR =6.24, 95% CI =2.53–15.36); nonshockable electrocardiography (EKG) rhythm (OR =5.67, 95% CI =1.93–16.62); cardiac arrest occurring in postoperative period (OR =7.35, 95% CI =2.89–18.74); and duration of CPR more than 30 minutes (OR =4.32, 95% CI =1.39–13.45). The prognostic factors associated with survival with complications were being greater

  18. [How to express results of 24-hour gastric pH measurement? Choice of a mode of expression in 27 healthy subjects].

    PubMed

    Vallot, T; Elouaer-Blanc, L; Garcia del Risco, F; Mignon, M; Vatier, J; Bonfils, S

    1988-01-01

    Twenty-four hour intragastric acidity was studied in 27 healthy subjects (mean age = 29 yrs) by continuous recording in standardized conditions. Data obtained were expressed according to several analytical methods as used extensively elsewhere. In our study, there was a wide discrepancy in results from one subject to another. The use of median values of pH was more appropriate than mean values to express half-hour acidity levels for 24 hours. The median value of H+ concentration is recommended as well. The median value of pH varied from 1 to 4.8 with a slight rise during the second half of the night. During the postprandial period, increase of pH values was prolonged over 2 h 30 in 50 p. 100 of subjects. Profile of pH allowed to demonstrate the distribution of pH value without excluding the extreme values. Both periodicity of pH measurement (30 or 60 min) and parameters used to quantify acidity (percentage of time or pH value at or below threshold values) did not modify results. As measured over a 24 hours period, the percentage of time (mean +/- SEM) at or below pH 1.5 and 3.5 was 54 +/- 3 p. 100 and 85 +/- 2 p. 100, respectively. Daytime and night-time profiles were similar. Mean 24 h H+ concentration (mean +/- SEM) was 47 +/- 35 mmol/l, with, once again, similarity between day and night-time values. The mean 24 h pH values underestimated true acidity with respect to median values.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Demand and characteristics of a psychiatric 24-hour emergency service performed by mandatory rotation of licensed psychiatrists in Swiss primary care

    PubMed Central

    Chmiel, Corinne; Rosemann, Thomas; Senn, Oliver

    2014-01-01

    Background To investigate characteristics of and satisfaction with psychiatric 24-hour emergency primary care performed by mandatory rotation of licensed psychiatrists as a viable baseline for possible reorganizational measures. Methods This was a questionnaire-based cross-sectional study (November 2010–April 2011). The number of patient–psychiatrist encounters, modes of contact, and patient and psychiatrist characteristics were assessed. Diagnoses were coded with ICD-10 (International Classification of Diseases, version 10). Results From 167 duty episodes, 74 (44%) were recorded. Of the psychiatrists (n=44), 52% were female, and mean age (standard deviation) was 49.9 (5.2) years. The median number of encounters per episode was 4 (interquartile range 0–8), mainly in the evenings. Demand for “face-to-face” (direct) patient visits was significantly more common (64.0%) than practice (1.3%) or telephone consultations (34.7%). In 83.8%, psychiatrists judged the encounter as adequate at the patient’s location. A total of 43 different diagnoses were recorded: mainly schizophrenic disorders (23.9%), suicidal behavior (15.2%), and acute stress reactions (10.3%). Psychiatrists felt burdened by services (62.5%): in 39.2%, they felt threatened; and in 6.8%, violence occurred. In 32.4%, bills were not paid for. If services were optional, 45.2% would participate. Conclusion Our findings indicate justified demand for direct mobile patient visits, suggesting that emergency care should be multifaceted, and sole provision of psychiatric care at stationed emergency facilities may not always be appropriate. Reorganization of 24-hour emergency services should carefully evaluate patient and provider’s needs before changing established structures. PMID:24707172

  20. Variations of nickel in plasma and urine during the work period.

    PubMed

    Høgetveit, A C; Barton, R T; Andersen, I

    1980-09-01

    One of the basic problems in monitoring exposure of nickel refining workers has been the unclear correlation between plasma nickel, urine nickel, and airborne nickel during the eight-hour work period or throughout the 24-hour day. In previous studies the authors have demonstrated the value of biological sampling in an occupational health program in the nickel processing industry. Whether a single plasma or single urine sample is an adequate gauge of exposure or whether 24-hour urine specimens or a three-day average plasma level are more accurate indices remained to be determined. The purpose of this paper is to report the results of studies of diurnal variations which affect the significance of single biological samples. In addition, data gathered on the correlation of plasma and urine nickel levels with soluble and insoluble nickel compounds in the atmosphere are presented. PMID:7192730

  1. Nonhazardous Urine Pretreatment Method

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.

    2012-01-01

    A method combines solid phase acidification with two non-toxic biocides to prevent ammonia volatilization and microbial proliferation. The safe, non-oxidizing biocide combination consists of a quaternary amine and a food preservative. This combination has exhibited excellent stabilization of both acidified and unacidified urine. During pretreatment tests, composite urine collected from donors was challenged with a microorganism known to proliferate in urine, and then was processed using the nonhazardous urine pre-treatment method. The challenge microorganisms included Escherichia coli, a common gram-negative bacteria; Enterococcus faecalis, a ureolytic gram-positive bacteria; Candida albicans, a yeast commonly found in urine; and Aspergillus niger, a problematic mold that resists urine pre-treatment. Urine processed in this manner remained microbially stable for over 57 days. Such effective urine stabilization was achieved using non-toxic, non-oxidizing biocides at higher pH (3.6 to 5.8) than previous methods in use or projected for use aboard the International Space Station (ISS). ISS urine pretreatment methods employ strong oxidants including ozone and hexavalent chromium (Cr(VI)), a carcinogenic material, under very acidic conditions (pH = 1.8 to 2.4). The method described here offers a much more benign chemical environment than previous pretreatment methods, and will lower equivalent system mass (ESM) by reducing containment volume and mass, system complexity, and crew time needed to handle pre-treatment chemicals. The biocides, being non-oxidizing, minimize the potential for chemical reactions with urine constituents to produce volatile, airborne contaminants such as cyanogen chloride. Additionally, the biocides are active under significantly less acidic conditions than those used in the current system, thereby reducing the degree of required acidification. A simple flow-through solid phase acidification (SPA) bed is employed to overcome the natural buffering

  2. Urine melanin

    MedlinePlus

    Normally, melanin is not present in urine. Normal value ranges may vary slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your doctor about the meaning of your specific test results.

  3. Urination Pain

    MedlinePlus

    ... Are Reading Upsetting News Reports? What to Say Vaccines: Which Ones & When? Smart School Lunches Emmy-Nominated Video "Cerebral Palsy: Shannon's Story" 5 Things to Know About Zika & Pregnancy First Aid: Urination ...

  4. Catecholamines - urine

    MedlinePlus

    ... can increase catacholamines in your urine. You may need to avoid the follow foods for several days before the test: Coffee Tea Bananas Chocolate Cocoa Citrus fruits Vanilla Many medicines can interfere with test results. ...

  5. Urine Preservative

    NASA Technical Reports Server (NTRS)

    Smith, Scott M. (Inventor); Nillen, Jeannie (Inventor)

    2001-01-01

    Disclosed is CPG, a combination of a chlorhexidine salt (such as chlorhexidine digluconate, chlorhexidine diacetate, or chlorhexidine dichloride) and n-propyl gallate that can be used at ambient temperatures as a urine preservative.

  6. Urine - bloody

    MedlinePlus

    ... movement The urine can also turn a red color from certain drugs, beets, or other foods. ... surgery or an injury? Have you recently eaten foods that may cause a change in color, like beets, berries, or rhubarb? Tests that may ...

  7. Bilirubin - urine

    MedlinePlus

    ... or gallbladder Considerations Bilirubin can break down in light. That is why babies with jaundice are sometimes placed under blue fluorescent lamps. Alternative Names Conjugated bilirubin - urine; Direct bilirubin - ...

  8. Ketones urine test

    MedlinePlus

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  9. Metabolism and excretion rates of parent and hydroxy-PAHs in urine collected after consumption of traditionally smoked salmon for Native American volunteers.

    PubMed

    Motorykin, Oleksii; Santiago-Delgado, Lisandra; Rohlman, Diana; Schrlau, Jill E; Harper, Barbara; Harris, Stuart; Harding, Anna; Kile, Molly L; Massey Simonich, Staci L

    2015-05-01

    Few studies have been published on the excretion rates of parent polycyclic aromatic hydrocarbons (PAHs) and hydroxy-polycyclic aromatic hydrocarbons (OH-PAHs) following oral exposure. This study investigated the metabolism and excretion rates of 4 parent PAHs and 10 OH-PAHs after the consumption of smoked salmon. Nine members of the Confederated Tribes of the Umatilla Indian Reservation consumed 50 g of traditionally smoked salmon with breakfast and five urine samples were collected during the following 24 h. The concentrations of OH-PAHs increased from 43.9 μg/g creatinine for 2-OH-Nap to 349 ng/g creatinine for 1-OH-Pyr, 3 to 6 h post-consumption. Despite volunteers following a restricted diet, there appeared to be a secondary source of naphthalene and fluorene, which led to excretion efficiencies greater than 100%. For the parent PAHs that were detected in urine, the excretion efficiencies ranged from 13% for phenanthrene (and its metabolite) to 240% for naphthalene (and its metabolites). The half-lives for PAHs ranged from 1.4 h for retene to 3.3h for pyrene. The half-lives for OH-PAHs were higher and ranged from 1.7 h for 9-OH-fluorene to 7.0 h for 3-OH-fluorene. The concentrations of most parent PAHs, and their metabolites, returned to the background levels 24 h post-consumption. PMID:25659315

  10. Ambulatory Hypertension Subtypes and 24-Hour Systolic and Diastolic Blood Pressure as Distinct Outcome Predictors in 8341 Untreated People Recruited From 12 Populations

    PubMed Central

    Li, Yan; Wei, Fang-Fei; Thijs, Lutgarde; Boggia, José; Asayama, Kei; Hansen, Tine W.; Kikuya, Masahiro; Björklund-Bodegård, Kristina; Ohkubo, Takayoshi; Jeppesen, Jørgen; Gu, Yu-Mei; Torp-Pedersen, Christian; Dolan, Eamon; Liu, Yan-Ping; Kuznetsova, Tatiana; Stolarz-Skrzypek, Katarzyna; Tikhonoff, Valérie; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Sandoya, Edgardo; Kawecka-Jaszcz, Kalina; Mena, Luis; Maestre, Gladys E.; Filipovský, Jan; Imai, Yutaka; O’Brien, Eoin; Wang, Ji-Guang; Staessen, Jan A.

    2015-01-01

    Background Data on risk associated with 24-hour ambulatory diastolic (DBP24) versus systolic (SBP24) blood pressure are scarce. Methods and Results We recorded 24-hour blood pressure and health outcomes in 8341 untreated people (mean age, 50.8 years; 46.6% women) randomly recruited from 12 populations. We computed hazard ratios (HRs) using multivariable-adjusted Cox regression. Over 11.2 years (median), 927 (11.1%) participants died, 356 (4.3%) from cardiovascular causes, and 744 (8.9%) experienced a fatal or nonfatal cardiovascular event. Isolated diastolic hypertension (DBP24≥80 mm Hg) did not increase the risk of total mortality, cardiovascular mortality, or stroke (HRs≤1.54; P≥0.18), but was associated with a higher risk of fatal combined with nonfatal cardiovascular, cardiac, or coronary events (HRs≥1.75; P≤0.0054). Isolated systolic hypertension (SBP24≥130 mm Hg) and mixed diastolic plus systolic hypertension were associated with increased risks of all aforementioned end points (P≤0.0012). Below age 50, DBP24 was the main driver of risk, reaching significance for total (HR for 1-SD increase, 2.05; P=0.0039) and cardiovascular mortality (HR, 4.07; P=0.0032) and for all cardiovascular end points combined (HR, 1.74; P=0.039) with a nonsignificant contribution of SBP24 (HR≤0.92; P≥0.068); above age 50, SBP24 predicted all end points (HR≥1.19; P≤0.0002) with a nonsignificant contribution of DBP24 (0.96≤HR≤1.14; P≥0.10). The interactions of age with SBP24 and DBP24 were significant for all cardiovascular and coronary events (P≤0.043). Conclusions The risks conferred by DBP24 and SBP24 are age dependent. DBP24 and isolated diastolic hypertension drive coronary complications below age 50, whereas above age 50 SBP24 and isolated systolic and mixed hypertension are the predominant risk factors. PMID:24906822

  11. Metabolic Engineering of Light and Dark Biochemical Pathways in Wild-Type and Mutant Strains of Synechocystis PCC 6803 for Maximal, 24-Hour Production of Hydrogen Gas

    SciTech Connect

    Ely, Roger L.; Chaplen, Frank W.R.

    2014-03-11

    This project used the cyanobacterial species Synechocystis PCC 6803 to pursue two lines of inquiry, with each line addressing one of the two main factors affecting hydrogen (H2) production in Synechocystis PCC 6803: NADPH availability and O2 sensitivity. H2 production in Synechocystis PCC 6803 requires a very high NADPH:NADP+ ratio, that is, the NADP pool must be highly reduced, which can be problematic because several metabolic pathways potentially can act to raise or lower NADPH levels. Also, though the [NiFe]-hydrogenase in PCC 6803 is constitutively expressed, it is reversibly inactivated at very low O2 concentrations. Largely because of this O2 sensitivity and the requirement for high NADPH levels, a major portion of overall H2 production occurs under anoxic conditions in the dark, supported by breakdown of glycogen or other organic substrates accumulated during photosynthesis. Also, other factors, such as N or S limitation, pH changes, presence of other substances, or deletion of particular respiratory components, can affect light or dark H2 production. Therefore, in the first line of inquiry, under a number of culture conditions with wild type (WT) Synechocystis PCC 6803 cells and a mutant with impaired type I NADPH-dehydrogenase (NDH-1) function, we used H2 production profiling and metabolic flux analysis, with and without specific inhibitors, to examine systematically the pathways involved in light and dark H2 production. Results from this work provided rational bases for metabolic engineering to maximize photobiological H2 production on a 24-hour basis. In the second line of inquiry, we used site-directed mutagenesis to create mutants with hydrogenase enzymes exhibiting greater O2 tolerance. The research addressed the following four tasks: 1. Evaluate the effects of various culture conditions (N, S, or P limitation; light/dark; pH; exogenous organic carbon) on H2 production profiles of WT cells and an NDH-1 mutant; 2. Conduct metabolic flux analyses for

  12. Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy.

    PubMed

    Seegers, Joachim; Bergau, Leonard; Expósito, Pascal Muñoz; Bauer, Axel; Fischer, Thomas H; Lüthje, Lars; Hasenfuß, Gerd; Friede, Tim; Zabel, Markus

    2016-07-01

    In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holter variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holter for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 ± 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (≥1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks

  13. Nighttime sleep duration, 24-hour sleep duration and risk of all-cause mortality among adults: a meta-analysis of prospective cohort studies

    PubMed Central

    Shen, Xiaoli; Wu, Yili; Zhang, Dongfeng

    2016-01-01

    A dose-response meta-analysis was conducted to summarize evidence from prospective cohort studies about the association of nighttime sleep duration and 24-hour sleep duration with risk of all-cause mortality among adults. Pertinent studies were identified by a search of Embase and PubMed databases to March 2015. A two-stage random-effects dose–response meta-analysis was used to combine study-specific relative risks and 95% confidence intervals [RRs (95% CIs)]. Thirty-five articles were included. Compared with 7 hours/day, the RRs (95% CIs) of all-cause mortality were 1.07 (1.03–1.13), 1.04 (1.01–1.07), 1.01 (1.00–1.02), 1.07 (1.06–1.09), 1.21 (1.18–1.24), 1.37 (1.32–1.42) and 1.55 (1.47–1.63) for 4, 5, 6, 8, 9, 10 and 11 hours/day of nighttime sleep, respectively (146,830 death cases among 1,526,609 participants), and the risks were 1.09 (1.04–1.14), 1.05 (1.02–1.09), 1.02 (1.00–1.03), 1.08 (1.05–1.10), 1.27 (1.20–1.36), 1.53 (1.38–1.70) and 1.84 (1.59–2.13) for 4, 5, 6, 8, 9, 10 and 11 hours/day of 24-hour sleep, respectively (101,641 death cases among 903,727 participants). The above relationships were also found in subjects without cardiovascular diseases and cancer at baseline, and other covariates did not influence the relationships substantially. The results suggested that 7 hours/day of sleep duration should be recommended to prevent premature death among adults. PMID:26900147

  14. Control of bleeding by silk ligation and diathermy coagulation during tonsillectomy: A comparison of efficacy of the two techniques in the first 24 hours after surgery

    PubMed Central

    Anwar, Khurshid; Ahmad, Rafiq; Khan, Muneeb

    2015-01-01

    Objective: To assess and compare the relative efficacy of silk ligation and diathermy coagulation techniques in controlling bleeding during tonsillectomy in the first 24 hours. Methods: This prospective study was conducted at the Department of ENT, Khalifa Gul Nawaz Teaching Hospital, Bannu and this department related consultants’ private clinics from January 1, 2012 to December 31, 2014. The study included 180 cases. All patients included were having history of recurrent, acute tonsillitis, with more than 6–7 episodes in one year, five episodes per year for two years, or three episodes per year for three years. All the surgeries were performed by dissection method. Haemostasis during the procedure was secured by either ligation with silk 1 or using diathermy. The results were analyzed using SPSS 16.0 for windows. Results: A total of180 cases were included in the study. The ages of the patients ranged from 5 to 40 years with the mean age of 15.56 years and a std.deviation of +/- 8.24. The male to female ratio was 1.25:1. The number of hemorrhages occurring was greater in the ‘diathermy coagulation’ group as compared to the ‘silk ligation’ group. However, the observed difference was statistically insignificant (p >.05). Conclusion: Primary haemorrhage occurring during tonsillectomy is a serious threat and control of bleeding during the procedure should therefore be meticulous. Both suture ligation and coagulation diathermy for control of bleeders during the procedure by dissection method are equally effective. PMID:26430438

  15. Canadian 24-Hour Movement Guidelines for Children and Youth: Exploring the perceptions of stakeholders regarding their acceptability, barriers to uptake, and dissemination.

    PubMed

    Faulkner, Guy; White, Lauren; Riazi, Negin; Latimer-Cheung, Amy E; Tremblay, Mark S

    2016-06-01

    Engaging stakeholders in the development of guidelines and plans for implementation is vital. The purpose of this study was to examine stakeholders' (parents, teachers, exercise professionals, paediatricians, and youth) perceptions of the Canadian 24-Hour Movement Behaviour Guidelines for Children and Youth ("Movement Guidelines"). Stakeholders (n = 104) engaged in semi-structured focus groups or interviews to discuss the perceived acceptability of the guidelines, potential barriers to implementation, and preferred methods and messengers of dissemination. A thematic analysis was conducted. Overall, there was consistent support across all stakeholder groups, with the exception of youth participants, for the Movement Guidelines. Stakeholders identified a range of barriers to the uptake of the guidelines including concerns with accurately defining key terms such as "recreational" screen time; everyday challenges such as financial and time constraints; and the possibility of the Movement Guidelines becoming just another source of stress and guilt for already busy and overwhelmed parents. Participants identified a range of recommended methods and messengers for future dissemination. School and medical settings were the most commonly recommended settings through which dissemination efforts should be delivered. Overall, participants representing a range of stakeholder groups were receptive to the new Movement Guidelines and endorsed their value. In complementing the Movement Guidelines, messaging and resources will need to be developed that address common concerns participants had regarding their dissemination and implementation. PMID:27306436

  16. A Day in the Life of Millisecond Pulsar J1713+0747: Limits on Timing Precision Over 24 Hours and Implications for Gravitational Wave Detection

    NASA Astrophysics Data System (ADS)

    Dolch, Timothy; Bailes, M.; Bassa, C.; Bhat, R.; Bhattacharyya, B.; Champion, D.; Chatterjee, S.; Cognard, I.; Cordes, J. M.; Crowter, K.; Demorest, P.; Finn, L. S.; Fonseca, E.; Hessels, J.; Hobbs, G.; Janssen, G.; Jones, G.; Jordan, C.; Karuppusamy, R.; Keith, M.; Kramer, M.; Kraus, A.; Lam, M. T.; Lazarus, P.; Lazio, J.; Lee, K.; Levin, L.; Liu, K.; Lorimer, D.; Manchester, R. N.; McLaughlin, M.; Palliyaguru, N.; Perrodin, D.; Petroff, E.; Rajwade, K.; Rankin, J. M.; Ransom, S. M.; Rosenblum, J.; Roy, J.; Shannon, R.; Stappers, B.; Stinebring, D.; Stovall, K.; Teixeira, M.; van Leeuwen, J.; van Straten, W.; Verbiest, J.; Zhu, W.

    2014-01-01

    A 24-hour global observation of millisecond radio pulsar J1713+0747 was undertaken by the International Pulsar Timing Array (IPTA) collaboration as an effort to better quantify sources of noise in this object, which is regularly timed for the purpose of detecting gravitational waves (GWs). Given an 8-year timing RMS of 30ns, it is regarded as one of the best precision clocks in the PTA. However, sources of timing noise visible on timescales longer than the usual 20-30min biweekly observation may nonetheless be present. Data from the campaign were taken contiguously with the Parkes, Arecibo, Green Bank, GMRT, LOFAR, Effelsberg, WSRT, Lovell, and Nancay radio telescopes. The combined pulse times-of-arrival provide an estimate of the absolute noise floor, in other words, what unaccounted sources of timing noise impede an otherwise simple sqrt(N) improvement in timing precision, where N is the number of pulses in a single observing session. We present first results of specific phenomena probed on the unusual timescale of tens of hours, in particular interstellar scattering (ISS), and discuss the degree to which ISS affects precision timing. Finally, we examine single pulse information during selected portions of the observation and determine the degree to which the pulse jitter of J1713+0747 varies throughout the course of the day-long dataset.

  17. Age-dependent changes in 24-hour rhythms of catecholamine content and turnover in hypothalamus, corpus striatum and pituitary gland of rats injected with Freund's adjuvant

    PubMed Central

    Cano, Pilar; Cardinali, Daniel P; Chacon, Fernando; Castrillón, Patricia O; Reyes Toso, Carlos A; Esquifino, Ana I

    2001-01-01

    Background Little information is available on the circadian sequela of an immune challenge in the brain of aged rats. To assess them, we studied 24-hour rhythms in hypothalamic and striatal norepinephrine (NE) content, hypothalamic and striatal dopamine (DA) turnover and hypophysial NE and DA content, in young (2 months) and aged (18–20 months) rats killed at 6 different time intervals, on day 18th after Freund's adjuvant or adjuvant's vehicle administration. Results Aging decreased anterior and medial hypothalamic NE content, medial and posterior hypothalamic DA turnover, and striatal NE concentration and DA turnover. Aging also decreased NE and DA content in pituitary neurointermediate lobe and augmented DA content in the anterior pituitary lobe. Immunization by Freund's adjuvant injection caused: (i) reduction of DA turnover in anterior hypothalamus and corpus striatum; (ii) acrophase delay of medial hypothalamic DA turnover in old rats, and of striatal NE content in young rats; (iii) abolition of 24-h rhythm in NE and DA content of neurointermediate pituitary lobe, and in DA content of anterior lobe, of old rats. Conclusions The decline in catecholamine neurotransmission with aging could contribute to the decrease of gonadotropin and increase of prolactin release reported in similar groups of rats. Some circadian responses to immunization, e.g. suppression of 24-h rhythms of neurointermediate lobe NE and DA and of anterior lobe DA were seen only in aged rats. PMID:11741510

  18. Computer simulation of the effect of dDAVP with saline loading on fluid balance after 24-hour head-down tilt

    NASA Technical Reports Server (NTRS)

    Srinivasan, R. S.; Simanonok, K. E.; Charles, J. B.

    1994-01-01

    Fluid loading (FL) before Shuttle reentry is a countermeasure currently in use by NASA to improve the orthostatic tolerance of astronauts during reentry and postflight. The fluid load consists of water and salt tablets equivalent to 32 oz (946 ml) of isotonic saline. However, the effectiveness of this countermeasure has been observed to decrease with the duration of spaceflight. The countermeasure's effectiveness may be improved by enhancing fluid retention using analogs of vasopressin such as lypressin (LVP) and desmopressin (dDAVP). In a computer simulation study reported previously, we attempted to assess the improvement in fluid retention obtained by the use of LVP administered before FL. The present study is concerned with the use of dDAVP. In a recent 24-hour, 6 degree head-down tilt (HDT) study involving seven men, dDAVP was found to improve orthostatic tolerance as assessed by both lower body negative pressure (LBNP) and stand tests. The treatment restored Luft's cumulative stress index (cumulative product of magnitude and duration of LBNP) to nearly pre-bedrest level. The heart rate was lower and stroke volume was marginally higher at the same LBNP levels with administration of dDAVP compared to placebo. Lower heart rates were also observed with dDAVP during stand test, despite the lower level of cardiovascular stress. These improvements were seen with only a small but significant increase in plasma volume of approximately 3 percent. This paper presents a computer simulation analysis of some of the results of this HDT study.

  19. Gastroesophageal and pharyngeal reflux detection using impedance and 24-hour pH monitoring in asymptomatic subjects: defining the normal environment.

    PubMed

    Oelschlager, Brant K; Quiroga, Elina; Isch, John A; Cuenca-Abente, Federico

    2006-01-01

    Airway symptoms are often caused by aspiration of refluxed materials into the larynx. In this study we sought to define the frequency, character, and proximal extent of refluxed contents - including nonacid reflux-in normal subjects using intraluminal impedance to improve our understanding of the relationship between reflux and aspiration. Ten subjects, who had no symptoms of gastroesophageal reflux disease or airway disease, underwent impedance/pH monitoring with a catheter that allowed simultaneous esophageal and pharyngeal monitoring. Impedance detected 496 gastroesophageal reflux episodes in the 10 subjects during 240 hours of study. The majority, 399 (81% of the total) were acid reflux episodes (pH < 4). Ninety-seven were nonacid (pH > 4). Most reflux episodes (348 of 496) reached the mid esophagus (9 cm above lower esophageal sphincter). There were 51 reflux episodes that reached the pharynx (PR). Only 13 (25%) of PR were acidic (pH < 4), while 38 were nonacid. Twenty-six PR episodes were liquid and 25 were mixed (liquid and gas). The median number of PR episodes measured with impedance was 5 (0-10). In asymptomatic subjects, most episodes of gastroesophageal reflux are acidic and reach the midesophagus. Reflux into the PR appears to be more common than previously believed, and most of these episodes are not acidic. Thus, traditional 24-hour pH monitoring may underestimate the presence of pharyngeal reflux. The combination of impedance with pH monitoring markedly enhances our ability to accurately detect potential microaspiration.

  20. Urine culture - catheterized specimen

    MedlinePlus

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  1. Urination - difficulty with flow

    MedlinePlus

    Difficulty starting or maintaining a urine stream is called urinary hesitancy. ... men have some trouble with dribbling, weak urine stream, and starting urination. Another common cause is infection ...

  2. The effectiveness of BD Vacutainer® Plus Urinalysis Preservative Tubes in preservation of urine for chemical strip analysis and particle counting

    PubMed Central

    Ekşioğlu, Merve Kaymak; Madenci, Özlem Çakır; Yücel, Nihal; Elçi, Abdullah; Turhan, Bülent; Orhan, Gani; Orçun, Asuman

    2016-01-01

    Introduction The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (κ), false positive (FP) and false negative (FN) rates were evaluated. κ > 0.8 was accepted as good agreement. Results Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible. PMID:27346967

  3. "2001: A Space Odyssey" Revisited--The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    1998-01-01

    The prospects for "24 hour" commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, "high leverage" technologies--liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Ironrich volcanic glass, or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way, LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging front the engine's choked sonic throat--essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  4. 2001: A Space Odyssey Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley; Dudzinski, Leonard A.

    2003-01-01

    The prospects for 24 hour commuter flights to the Moon, similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale, are examined using two near term, high leverage technologies: liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and lunar-derived oxygen (LUNOX) production. Iron-rich volcanic glass, or orange soil, discovered during the Apollo 17 mission to Taurus-Littrow, has produced a 4 percent oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an afterburner into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat, essentially scramjet propulsion in reverse. By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that big engine performance can be obtained using smaller, more affordable, easier to test NTR engines. The use of high-density LOX in place of low density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or in-line Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an expendable mode initially, to maximize delivered surface payload on each mission. The increased payload is

  5. "2001: A Space Odyssey" Revisited: The Feasibility of 24 Hour Commuter Flights to the Moon Using NTR Propulsion with LUNOX Afterburners. Revised

    NASA Technical Reports Server (NTRS)

    Borowski, Stanley K.; Dudzinski, Leonard A.

    2001-01-01

    The prospects for "24 hour" commuter flights to the Moon. similar to that portrayed in 2001: A Space Odyssey but on a more Spartan scale. are examined using two near term. "high leverage" technologies-liquid oxygen (LOX)-augmented nuclear thermal rocket (NTR) propulsion and "lunar-derived" oxygen (LUNOX) production. Iron-rich volcanic glass. or "orange soil," discovered during the Apollo 17 mission to Taurus-Littrow. has produced a 4% oxygen yield in recent NASA experiments using hydrogen reduction. LUNOX development and utilization would eliminate the need to transport oxygen supplies from Earth and is expected to dramatically reduce the size, cost and complexity of space transportation systems. The LOX-augmented NTR concept (LANTR) exploits the high performance capability of the conventional liquid hydrogen (LH2)-cooled NTR and the mission leverage provided by LUNOX in a unique way. LANTR utilizes the large divergent section of its nozzle as an "afterburner" into which oxygen is injected and supersonically combusted with nuclear preheated hydrogen emerging from the engine's choked sonic throat-essentially "scramjet propulsion in reverse." By varying the oxygen-to-hydrogen mixture ratio, the LANTR engine can operate over a wide range of thrust and specific impulse (Isp) values while the reactor core power level remains relatively constant. The thrust augmentation feature of LANTR means that "big engine" performance can be obtained using smaller. more affordable. easier to test NTR engines. The use of high-density LOX in place of low-density LH2 also reduces hydrogen mass and tank volume resulting in smaller space vehicles. An implementation strategy and evolutionary lunar mission architecture is outlined which requires only Shuttle C or "in-line" Shuttle-derived launch vehicles, and utilizes conventional NTR-powered lunar transfer vehicles (LTVs), operating in an "expendable mode" initially, to maximize delivered surface payload on each mission. The increased

  6. Epidemiology of Urban Traffic Accident Victims Hospitalized More Than 24 Hours in a Level III Trauma Center, Kashan County, Iran, During 2012-2013

    PubMed Central

    Mahdian, Mehrdad; Sehat, Mojtaba; Fazel, Mohammad Reza; Moraveji, Alireza; Mohammadzadeh, Mahdi

    2015-01-01

    Background: Urban traffic accidents are an extensively significant problem in small and busy towns in Iran. This study tried to explore the epidemiological pattern of urban traffic accidents in Kashan and Aran-Bidgol cities, Iran. Objectives: This study aimed to assess various epidemiological factors affecting victims of trauma admitted to a main trauma center in Iran. Patients and Methods: During a retrospective study, data including age, sex, injury type and pattern, outcome, hospital stay and treatment expenditures regarding urban Road Traffic Accidents (RTAs) for one year (March 2012-March 2013) were obtained from the registry of trauma research center, emergency medical services and deputy of health of Kashan University of Medical Sciences. One-way ANOVA and chi-square tests were used to analyze data using SPSS version 16.0. P value < 0.05 was considered significant. Results: A total of 1723 victims (82.6% male, sex ratio of almost 5:1) were considered in this study. Mortality rate in trauma cases hospitalized more than 24 hours during our study was 0.8%. Young motorcyclist men with the rate of more than 103 per 10000 were the most vulnerable group. The most common injury was head injury (73.6%) followed by lower limb injury (33.2%). A significant association was found between mechanism of injury and head, lower limb, multiple injuries and high risk age group. Conclusions: Urban RTAs are one of the most important problems in Kashan and Aran-Bidgol cities, which impose a great economic burden on health system. Motorcyclists are the most vulnerable victims and multiple trauma and head injury are seen among them extensively. PMID:26101765

  7. Evaluation of the indications and arrhythmic patterns of 24 hour Holter electrocardiography among hypertensive and diabetic patients seen at OAUTHC, Ile-Ife Nigeria

    PubMed Central

    Adebayo, Rasaaq A; Ikwu, Amanze N; Balogun, Michael O; Akintomide, Anthony O; Mene-Afejuku, Tuoyo O; Adeyeye, Victor O; Bamikole, Olaniyi J; Bisiriyu, Luqman A; Ajayi, Olufemi E; Ogunyemi, Suraj A; Oketona, Omolola A

    2014-01-01

    Background There are very limited published studies in Nigeria on the use of 24 hour Holter electrocardiogram (Holter ECG) in the arrhythmic evaluation of hypertensive and diabetic patients. Objective To evaluate indications, arrhythmic pattern of Holter ECG, and heart rate variability (HRV) among patients with hypertensive heart disease (HHD) with or without heart failure and type 2 diabetes mellitus (T2DM) seen in our cardiac care unit. Methods Seventy-nine patients (32 males and 47 females) were studied consecutively over a year using Schiller type (MT-101) Holter ECG machine. Results Out of the 79 patients, 17 (21.5%) had HHD without heart failure, 33 (41.8%) had HHD with hypertensive heart failure (HHF), while 29 (36.7%) were T2DM patients. The mean (standard deviation) ages of HHD without heart failure, HHF and T2DM patients were 59.65 (±14.38), 65.15 (±14.30), and 54.66 (±8.88) respectively. The commonest indication for Holter ECG was palpitation (38%), followed by syncope (20.3%). Premature ventricular contraction was the commonest arrhythmic pattern among the 79 patients, especially among HHF patients. The HRV using standard deviation of all normal-normal intervals was significantly reduced in T2DM patients (81.03±26.33, confidence interval [CI] =71.02–91.05) compared to the HHD without heart failure (119.65±29.86, CI =104.30–135.00) and HHF (107.03±62.50, CI =84.00–129.19). There was a negative correlation between the duration of T2DM and HRV (r=−0.613). Conclusion Palpitation was the commonest Holter ECG indication and premature ventricular contractions were the commonest arrhythmic pattern among our patients. HRV was reduced in T2DM patients compared with hypertensive patients. PMID:25473303

  8. Effects of Potassium Magnesium Citrate Supplementation on 24-Hour Ambulatory Blood Pressure and Oxidative Stress Marker in Prehypertensive and Hypertensive Subjects.

    PubMed

    Vongpatanasin, Wanpen; Peri-Okonny, Poghni; Velasco, Alejandro; Arbique, Debbie; Wang, Zhongyun; Ravikumar, Priya; Adams-Huet, Beverly; Moe, Orson W; Pak, Charles Y C

    2016-09-15

    Diet rich in fruits, vegetables, and dairy products, known as the Dietary Approaches to Stop Hypertension (DASH) diet, is known to reduce blood pressure (BP) in hypertensive patients. More recently, the DASH diet was shown to reduce oxidative stress in hypertensive and nonhypertensive humans. However, the main nutritional components responsible for these beneficial effects of the DASH diet remain unknown. Because the DASH diet is rich in potassium (K), magnesium (Mg), and alkali, we performed a randomized, double-blinded, placebo-controlled study to compare effects of potassium magnesium citrate (KMgCit), potassium chloride (KCl), and potassium citrate (KCit) to allow dissociation of the three components of K, Mg, and citrate on 24-hour ambulatory BP and urinary 8-isoprostane in hypertensive and prehypertensive subjects, using a randomized crossover design. We found that KCl supplementation for 4 weeks induced a significant reduction in nighttime SBP compared with placebo (116 ± 12 vs 121 ± 15 mm Hg, respectively, p <0.01 vs placebo), whereas KMgCit and KCit had no significant effect in the same subjects (118 ± 11 and 119 ± 13 mm Hg, respectively, p >0.1 vs placebo). In contrast, urinary 8-isoprostane was significantly reduced with KMgCit powder compared with placebo (13.5 ± 5.7 vs 21.1 ± 10.5 ng/mgCr, respectively, p <0.001), whereas KCl and KCit had no effect (21.4 ± 9.1 and 18.3 ± 8.4, respectively, p >0.1 vs placebo). In conclusion, our study demonstrated differential effects of KCl and KMgCit supplementation on BP and the oxidative stress marker in prehypertensive and hypertensive subjects. Clinical significance of the antioxidative effect of KMgCit remains to be determined in future studies. PMID:27448942

  9. Evidence for Long-period (14-30 Days) and Against Short-period (12-24 Hours) Tidal Modulation of Volcanic Tremor at Arenal Volcano, Costa Rica

    NASA Astrophysics Data System (ADS)

    Hagerty, M. T.; Schwartz, S.; Revenaugh, J.

    2008-12-01

    Many studies have sought a correlation between the occurrence of earthquakes or volcanic activity and various Earth tide components, which would provide evidence for external tidal modulation of these geophysical phenomena. Several studies of short duration seismic experiments at Arenal Volcano in Costa Rica have found evidence of diurnal and semi-diurnal tidal periodicities in the seismic record. However, studies at other volcanoes, using longer time series, with improved spectral resolution, do not find tidal peaks in the seismic spectrum, but rather solar peaks (at exactly 12 and/or 24 hours), suggesting that the modulation is caused not by tidal stresses, but by weather related parameters - temperature, barometric pressure, rainfall. In contrast, recent studies of nonvolcanic tremor in the subduction zones of Japan and Cascadia do find evidence for tidal modulation of tremor activity with a period of 12.4 hours. Thus, the questions of whether or not earthquakes and volcanoes are triggered by external forces, and if so, whether these forces are related to elastic tides or to weather, are still highly relevant. We examine a continuous, 302-day long recording of ground motion at Arenal Volcano, Costa Rica, for potential solar and lunar periodicities in the volcanic seismicity. No evidence is found for significant energy in the semidiurnal (near 12 hr) or diurnal (near 24 hr) frequency bands, in contrast to previous, lower- resolution studies at Arenal. However, analysis with multi-taper method (MTM) and singular spectrum analysis (SSA) reveals significant low-frequency (f < .005 cycles/hr) energy in the tremor and explosivity series, including 14 and 30-day quasi-periodic components, relative to a red noise hypothesis. We attempt to fit the data to long-period tidal frequencies in order to verify potential tidal modulation of the long-period seismic energy at Arenal.

  10. Effect of melatonin on 24-hour rhythms of ornithine decarboxylase activity and norepinephrine and acetylcholine synthesis in submaxillary lymph nodes and spleen of young and aged rats.

    PubMed

    Cardinali, D P; Brusco, L I; García Bonacho, M; Esquifìno, A I

    1998-05-01

    Young (50 days old) and old (18 months old) Sprague-Dawley rats were injected with mycobacterial Freund's adjuvant to produce an inflammatory disease of the joints and were studied the day before, and on days 6, 12 and 18 after injection. At every postinjection interval examined, old rats had significantly lower circadian amplitudes of pineal melatonin content. On day 18 of arthritis development, decreased levels of pineal melatonin were also seen in young rats. A second study, carried out 18 days after the injection of Freund's complete adjuvant and after 17 daily injections of 10 or 100 microg of melatonin in the evening, indicated that melatonin treatment restored the inflammatory response in old rats (assessed plethysmographically in hind paws) to the level found in young animals. In young rats, an inflammation-promoting effect of 100 microg melatonin could be demonstrated. As a consequence of the immune reaction, submaxillary lymph node and splenic ornithine decarboxylase activity (an index of lymph cell proliferation) augmented significantly, with acrophases of 24-hour rhythms in the afternoon for lymph nodes or in the morning for spleen. Mesor and amplitude of ornithine decarboxylase rhythm were lowest in old rats, while melatonin injection generally augmented its amplitude. Lymph node and splenic tyrosine hydroxylase activity (a presynaptic adrenergic marker) reached maximal values during early night hours while maximal values of [3H]acetylcholine synthesis (a presynaptic cholinergic marker) occurred during the afternoon in lymph nodes. Amplitude and mesor of these rhythms were lowest in old rats, an effect generally counteracted by melatonin treatment. The results suggest that inflammation is accompanied by an age-dependent, significant depression of pineal melatonin synthesis during adjuvant-induced arthritis and a decreased amplitude of the circadian rhythm of immune cell proliferation and autonomic activity in lymph nodes and spleen. These effects are

  11. 17-hydroxycorticosteroid urine test

    MedlinePlus

    ... disorder that occurs when the body has a high level of cortisol. ... 2 to 12 mg per 24 hours Normal value ranges may vary slightly ... your provider about the meaning of your specific test results.

  12. The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

    NASA Astrophysics Data System (ADS)

    Tjahaja, Poppy Intan; Sukmabuana, Putu; Aisyah, Neneng Nur

    2010-12-01

    The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236±0.677 kBq/L and 1.704±0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO4 addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 μSv/year and 0.532 μSv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 μSv/year.

  13. The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

    SciTech Connect

    Tjahaja, Poppy Intan; Sukmabuana, Putu; Aisyah, Neneng Nur

    2010-12-23

    The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.

  14. Decentralized collection of iodinated x-ray contrast media in hospitals-results of the feasibility study and the practice test phase.

    PubMed

    Heinzmann, Bernd; Schwarz, Rolf-Jürgen; Schuster, Petra; Pineau, Claire

    2008-01-01

    Iodinated x-ray contrast media are unmetabolized and almost completely with the urine in 24 hours emitted in the wastewater after their application by human being. These very polar, hydrophilic and hardly biodegradable substances have already been detected in the water cycle. The objective of this R&D project is the collection of the x-ray contrast media already at the source in the hospital and so the avoidance of an emission in the water cycle. Three concepts have been developed in the scope of this R&D project: a centralized collection concept with a no-mix toilet in the radiology unit, a decentralized collection concept featuring a no-mix toilet for every of the ward and another decentralized collection concept with mobile urine containers for the wards. The evaluation of the collection concepts has taken systematically into consideration costs, acceptance and a value benefit analysis. The feasibility study has shown that a separated collection of iodinated x-ray contrast media in hospitals is possible through the implementation of a decentralized urine collection concept using mobile urine containers. This decentralised collection concept was tested in each case on one main focus ward of two representative German hospitals for 20 weeks. In both wards of the hospitals around 60% of patients with an examination of x-ray contrast media took part in the voluntary urine collection. The AOX arose from the iodinated x-ray contrast media in the collected urine. The averaged measured AOI concentration in the patient's urine was 18 g/l. The total costs, formed by the costs for staff, material and disposal, were estimated at 10 euro per patient, 7 euro per litre urine and approximate 380 euro per kilogramme iodine for the separated urine collection in hospitals. The main part of the total costs is formed by the costs for staff with around 80%. This R&D project has shown that the separated collection of the patients' urine with a simple and decentralised collection

  15. Some historical aspects of urinals and urine receptacles.

    PubMed

    Mattelaer, J J

    1999-06-01

    In the history of mankind the first receptacles for urine were made and employed for diagnostic purposes and developed over centuries to a sophisticated matula. In ancient Greek and Roman history, chamber pots existed and urine was collected to bleach sheets, but it was only in the late medieval and renaissance times that a real urine receptacle or urinal for daily use was developed. We give a short description of the materials used, including clay, pewter, copper, and silver, but more sophisticated receptacles made of china, such as the bourdaloue, and of glass, such as the Kuttrolf, were also developed for use during long church ceremonies. Less known are the wooden "pipes" from Turkestan, used to keep babies dry. In the long history of mankind, urinals sometimes became very original objects.

  16. Some historical aspects of urinals and urine receptacles.

    PubMed

    Mattelaer, J J

    1999-06-01

    In the history of mankind the first receptacles for urine were made and employed for diagnostic purposes and developed over centuries to a sophisticated matula. In ancient Greek and Roman history, chamber pots existed and urine was collected to bleach sheets, but it was only in the late medieval and renaissance times that a real urine receptacle or urinal for daily use was developed. We give a short description of the materials used, including clay, pewter, copper, and silver, but more sophisticated receptacles made of china, such as the bourdaloue, and of glass, such as the Kuttrolf, were also developed for use during long church ceremonies. Less known are the wooden "pipes" from Turkestan, used to keep babies dry. In the long history of mankind, urinals sometimes became very original objects. PMID:10418087

  17. Sex and age-related differences in performance in a 24-hour ultra-cycling draft-legal event – a cross-sectional data analysis

    PubMed Central

    2014-01-01

    Background The purpose of this study was to examine the sex and age-related differences in performance in a draft-legal ultra-cycling event. Methods Age-related changes in performance across years were investigated in the 24-hour draft-legal cycling event held in Schötz, Switzerland, between 2000 and 2011 using multi-level regression analyses including age, repeated participation and environmental temperatures as co-variables. Results For all finishers, the age of peak cycling performance decreased significantly (β = −0.273, p = 0.036) from 38 ± 10 to 35 ± 6 years in females but remained unchanged (β = −0.035, p = 0.906) at 41.0 ± 10.3 years in males. For the annual fastest females and males, the age of peak cycling performance remained unchanged at 37.3 ± 8.5 and 38.3 ± 5.4 years, respectively. For all female and male finishers, males improved significantly (β = 7.010, p = 0.006) the cycling distance from 497.8 ± 219.6 km to 546.7 ± 205.0 km whereas females (β = −0.085, p = 0.987) showed an unchanged performance of 593.7 ± 132.3 km. The mean cycling distance achieved by the male winners of 960.5 ± 51.9 km was significantly (p < 0.001) greater than the distance covered by the female winners with 769.7 ± 65.7 km but was not different between the sexes (p > 0.05). The sex difference in performance for the annual winners of 19.7 ± 7.8% remained unchanged across years (p > 0.05). The achieved cycling distance decreased in a curvilinear manner with advancing age. There was a significant age effect (F = 28.4, p < 0.0001) for cycling performance where the fastest cyclists were in age group 35–39 years. Conclusion In this 24-h cycling draft-legal event, performance in females remained unchanged while their age of peak cycling performance decreased and performance in males improved while their age of peak cycling performance remained unchanged. The annual fastest females and males were 37.3 ± 8.5 and 38.3 ± 5.4 years old, respectively. The sex

  18. Estimation of arsenic intake from drinking water and food (raw and cooked) in a rural village of northern Chile. Urine as a biomarker of recent exposure.

    PubMed

    Diaz, Oscar Pablo; Arcos, Rafael; Tapia, Yasna; Pastene, Rubén; Velez, Dínoraz; Devesa, Vicenta; Montoro, Rosa; Aguilera, Valeska; Becerra, Miriam

    2015-05-22

    The aim of this study was to estimate both the contribution of drinking water and food (raw and cooked) to the total (t-As) and inorganic (i-As) arsenic intake and the exposure of inhabitants of Socaire, a rural village in Chile´s Antofagasta Region, by using urine as biomarker. The i-As intake from food and water was estimated using samples collected between November 2008 and September 2009. A 24-hour dietary recall questionnaire was given to 20 participants. Drinking water, food (raw and cooked) and urine samples were collected directly from the homes where the interviewees lived. The percentage of i-As/t-As in the drinking water that contributed to the total intake was variable (26.8-92.9). Cereals and vegetables are the food groups that contain higher concentrations of i-As. All of the participants interviewed exceeded the reference intake FAO/OMS (149.8 µg∙i-As·day⁻¹) by approximately nine times. The concentration of t-As in urine in each individual ranged from 78 to 459 ng·mL⁻¹. Estimated As intake from drinking water and food was not associated with total urinary As concentration. The results show that both drinking water and food substantially contribute to i-As intake and an increased exposure risk to adult residents in contaminated areas.

  19. Estimation of Arsenic Intake from Drinking Water and Food (Raw and Cooked) in a Rural Village of Northern Chile. Urine as a Biomarker of Recent Exposure

    PubMed Central

    Diaz, Oscar Pablo; Arcos, Rafael; Tapia, Yasna; Pastene, Rubén; Velez, Dínoraz; Devesa, Vicenta; Montoro, Rosa; Aguilera, Valeska; Becerra, Miriam

    2015-01-01

    The aim of this study was to estimate both the contribution of drinking water and food (raw and cooked) to the total (t-As) and inorganic (i-As) arsenic intake and the exposure of inhabitants of Socaire, a rural village in Chile´s Antofagasta Region, by using urine as biomarker. The i-As intake from food and water was estimated using samples collected between November 2008 and September 2009. A 24-hour dietary recall questionnaire was given to 20 participants. Drinking water, food (raw and cooked) and urine samples were collected directly from the homes where the interviewees lived. The percentage of i-As/t-As in the drinking water that contributed to the total intake was variable (26.8–92.9). Cereals and vegetables are the food groups that contain higher concentrations of i-As. All of the participants interviewed exceeded the reference intake FAO/OMS (149.8 µg∙i-As·day−1) by approximately nine times. The concentration of t-As in urine in each individual ranged from 78 to 459 ng·mL−1. Estimated As intake from drinking water and food was not associated with total urinary As concentration. The results show that both drinking water and food substantially contribute to i-As intake and an increased exposure risk to adult residents in contaminated areas. PMID:26006131

  20. Urinary 6-sulphatoxymelatonin excretion is increased in rats after 24 hours of exposure to vertical 50 Hz, 100 {micro}T magnetic field

    SciTech Connect

    Bakos, J.; Nagy, N.; Thuroczy, G.; Szabo, L.D.

    1997-05-01

    The effect of exposure to a 50 Hz, vertical magnetic field on the excretion of urinary 6-sulphatoxymelatonin (aMT6s) of rats was studied in a self-controlled experiment. Ten male Wistar rats were kept under 9:15 h light:dark conditions in metabolic cages. The rats were exposed to 1.0 or 100 {micro}T flux density for 24 h. The excretion of aMT6s, which is the primary metabolite of melatonin in the urine, did not show a statistically significant decrease, as measured by {sup 125}I radioimmunoassay, during or after magnetic field exposure of rats to either flux density. At 100 {micro}T flux density, the increase of aMT6s excretion on the day after exposure was statistically significant (P < .02), compared with the value under exposure, but was not significant compared with the baseline values before exposure.

  1. Validity Testing of the Stopwatch Urine Stream Interruption Test in Radical Prostatectomy Patients

    PubMed Central

    Robinson, Joanne P.; Burrell, Sherry A.; Avi-Itzhak, Tamara; McCorkle, Ruth

    2012-01-01

    Objective To assess convergent validity of the stopwatch urine stream interruption test (UST). Specific aims were to describe relationships among stopwatch UST scores and four common clinical indices of pelvic floor muscle strength: 24-hour urine leakage, confidence in performing pelvic muscle exercise, 24-hour pad count, and daily pelvic muscle exercise count. Design Secondary analysis; instrumentation study. Methods The final sample consisted of baseline stopwatch UST scores and measurements of comparison variables from 47 participants in a randomized clinical trial of three approaches to pelvic floor training for patients with urinary incontinence following radical prostatectomy. The sample size provided 80% power to detect correlations of moderate strength or higher. The stopwatch UST was conducted in an examination room at the study site by trained study personnel. Measurements of comparison variables were obtained from three instruments: 24-hour pad test, Broome Pelvic Muscle Self-Efficacy Scale, and 3-day bladder diary. Relationships among study variables were evaluated with Pearson’s correlation coefficients. Results Stopwatch UST scores were moderately correlated with 24-hour urine leakage on the 24-hour pad test (r = .35, p < .05), the most robust comparison measure. Correlations between stopwatch UST scores and all other comparison measures were in the appropriate direction, although weak and did not reach statistical significance Conclusion Findings suggest the stopwatch UST may be a valid index of pelvic floor muscle strength in men following radical prostatectomy. With further testing, the stopwatch UST could become a valuable clinical tool for assessing pelvic floor muscle strength in radical prostatectomy patients with urinary incontinence. PMID:22825573

  2. Estimation by a 24-hour study of the daily dose of intra-oral mercury vapor inhaled after release from dental amalgam

    SciTech Connect

    Berglund, A. )

    1990-10-01

    The difficulties associated with estimations of daily doses of inhaled mercury vapor released from dental amalgam are considerable. Existing data are often unreliable, especially if they are based on a single or a small series of samples of intra-oral concentrations of mercury vapor before, during, and after chewing stimulation. In the present paper, the aim was to obtain a more representative estimation of the daily dose of mercury vapor inhaled from amalgam fillings by measurement of amounts of mercury vapor released in the oral cavity during 24 h, under conditions that were as normal as possible. A series of measurements was carried out on each of 15 subjects, with at least nine occlusal surfaces restored with dental amalgam, and on five subjects without any amalgam restorations. The subjects had to follow a standardized schedule for 24 h, whereby they ate, drank, and brushed their teeth at pre-determined time periods. The amount of mercury vapor released per time unit was measured at intervals of 30-45 min by means of a measuring system based on atomic absorption spectrophotometry. None of the subjects was professionally exposed to mercury, and all of their amalgam fillings were more than one year old. Study casts were made for each subject, and the area of the amalgam surfaces was measured. Samples of urine and saliva were analyzed so that values for the mercury concentrations and the rate of release of mercury into saliva could be obtained. The average frequency of fish meals per month was noted.

  3. Osmolality urine test

    MedlinePlus

    ... and urine concentration. Osmolality is a more exact measurement of urine concentration than the urine specific gravity ... slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  4. Concentration of marijuana metabolites in the urine after ingestion of hemp seed tea.

    PubMed

    Steinagle, G C; Upfal, M

    1999-06-01

    To determine whether ingestion of hemp seed tea could result in positive urine drug screens for cannabinoids, volunteers were recruited to donate urine after consuming hemp seed or placebo tea. Among the 22 participants, 10 ingested 12 ounces of hemp seed tea, 10 ingested 24 ounces, and 2 ingested 12 ounces of placebo tea. Urine cannabinoid specimens were obtained at baseline and at 4, 8, and 24 hours after ingestion. A total of 10 specimens had trace quantities of cannabinoids detected in 7 subjects on gas chromatography/mass spectrometry testing, all below the Department of Transportation cutoff level of 15 ng/mL. These results demonstrate that under the conditions of this study, hemp seed tea consumption can result in detectable urine cannabinoids but would not trigger a positive EMIT or gas chromatography/mass spectrometry urine drug test for cannabinoids.

  5. Effects of Gentle Human Touch and Field Massage on Urine Cortisol Level in Premature Infants: A Randomized, Controlled Clinical Trial

    PubMed Central

    Asadollahi, Malihe; Jabraeili, Mahnaz; Mahallei, Majid; Asgari Jafarabadi, Mohammad; Ebrahimi, Sakine

    2016-01-01

    Introduction: Hospitalization in neonatal intensive care unit may leads to many stresses for premature infants. Since premature infants cannot properly process stressors, identifying interventions that reduce the stress level for them is seems necessary. The aim of present study was to compare the effects of Field massage and Gentle Human Touch (GHT) techniques on the urine level of cortisol, as an indicator of stress in preterm infants. Methods: This randomized, controlled clinical trial was carried out in Al-Zahra hospital, Tabriz. A total of 84 premature infants were randomly assigned into three groups. First groups were touched by their mothers three times a day (15 minutes in each session) for 5 days by GHT technique. The second group was received 15 minutes Field massage with sunflower oil three times a day by their mothers for 5 days. The third group received routine care. In all groups, 24-hours urine samples were collected in the first and sixth day after the intervention and analyzed for cortisol level. Data were analyzed by SPSS software. Results: There were significant differences between mean of changes in cortisol level between GHT and control groups and Field massage and control groups (0.026). Conclusion: Although the massage with Field technique resulted in a significant reduction in blood cortisol level, but the GHT technique have also a similar effect. So, both methods are recommended for decreasing of stress in preterm infants. PMID:27752484

  6. Enmeration of Campylobacter spp., Escherichia coli, and Salmonella in broiler carcass rinses before and after simulated transport in artificial ice for 24 hours

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The maintenance and survival of target pathogens during transport from the field collection site to the analytical laboratory is essential to obtaining accurate and reliable data. This study was conducted to compare the abilities of sterile tap water (SW), buffered peptone water (BPW) and universal...

  7. Development and Pilot Testing of 24-Hour Multiple-Pass Recall to Assess Dietary Intake of Toddlers of Somali- and Iraqi-Born Mothers Living in Norway

    PubMed Central

    Grewal, Navnit Kaur; Mosdøl, Annhild; Aunan, Marte Bergsund; Monsen, Carina; Torheim, Liv Elin

    2014-01-01

    The aim of this study was to develop, test, and evaluate a 24-h recall procedure to assess the dietary intake of toddlers of Somali- and Iraqi-born mothers living in Norway. A protocol for a 24-h multiple-pass recall procedure, registration forms, and visual tools (a picture library for food identification and portion size estimation) was developed and tested in 12 mothers from Somalia and Iraq with children aged 10–21 months. Five female field workers were recruited and trained to conduct the interviews. Evaluation data for the 24-h recall procedure were collected from both the mothers and the field workers. Nutrient intake was calculated using a Norwegian dietary calculation system. Each child’s estimated energy intake was compared with its estimated energy requirement. Both the mothers and the field workers found the method feasible and the visual tools useful. The estimated energy intake corresponded well with the estimated energy requirement for most of the children (within mean ± 2 SD, except for three). The pilot study identified the need for additional foods in the picture library and some crucial aspects in training and supervising the field workers to reduce sources of error in the data collection. PMID:24949548

  8. Does examination of fecal samples 24 hours after cestocide treatment increase the sensitivity of Anoplocephala spp. detection in naturally infected horses?

    PubMed Central

    Elsener, Johanne; Villeneuve, Alain

    2011-01-01

    Fecal samples were examined immediately before and 24 to 48 h after cestocide treatment for a comparative detection of tapeworm-positive horses. In early winter, 17 weanlings, 20 yearlings, 15 2-year-old horses, 24 breeding mares, and 2 stallions were treated with praziquantel in combination with a macrocyclic lactone. The horses were presumed to be naturally infected with tapeworms after pasture grazing. Fecal samples were collected before treatment (Day 0), at 24 or 48 h after treatment (Day 1–2), and 16 to 21 d after treatment (Day 16–21). A Wisconsin test was done on all fecal samples. Odds of detection of infection for all age groups increased by a factor of 2.04 [95% confidence interval (CI): 1.30 to 3.20] from Day 0 to Day 1–2 (P = 0.002). PMID:21532821

  9. Does examination of fecal samples 24 hours after cestocide treatment increase the sensitivity of Anoplocephala spp. detection in naturally infected horses?

    PubMed

    Elsener, Johanne; Villeneuve, Alain

    2011-02-01

    Fecal samples were examined immediately before and 24 to 48 h after cestocide treatment for a comparative detection of tapeworm-positive horses. In early winter, 17 weanlings, 20 yearlings, 15 2-year-old horses, 24 breeding mares, and 2 stallions were treated with praziquantel in combination with a macrocyclic lactone. The horses were presumed to be naturally infected with tapeworms after pasture grazing. Fecal samples were collected before treatment (Day 0), at 24 or 48 h after treatment (Day 1-2), and 16 to 21 d after treatment (Day 16-21). A Wisconsin test was done on all fecal samples. Odds of detection of infection for all age groups increased by a factor of 2.04 [95% confidence interval (CI): 1.30 to 3.20] from Day 0 to Day 1-2 (P = 0.002).

  10. Vancomycin 24-Hour Area under the Curve/Minimum Bactericidal Concentration Ratio as a Novel Predictor of Mortality in Methicillin-Resistant Staphylococcus aureus Bacteremia

    PubMed Central

    Britt, Nicholas S.; Patel, Nimish; Horvat, Rebecca T.

    2016-01-01

    While previous studies have examined the association between vancomycin (VAN) exposure and MIC with regard to outcomes in methicillin-resistant Staphylococcus aureus bacteremia (MRSA-B), none have explored if a relationship exists with the VAN minimum bactericidal concentration (MBC). The objective of this study was to evaluate the VAN 24-h area under the curve (AUC24)/MBC ratio as a pharmacodynamic predictor of mortality. This retrospective cohort study included patients treated with VAN for MRSA-B with the primary outcome of 30-day all-cause mortality. Data collected included patient demographics, comorbidities, antimicrobial treatment data, therapeutic drug levels, and laboratory and microbiological data. Vancomycin MICs and MBCs were determined by Etest (MIC only) and broth microdilution (BMD). The vancomycin AUC24 was determined by pharmacokinetic maximum a posteriori probability Bayesian (MAP-Bayesian) analysis. The most significant breakpoint for 30-day mortality was determined by classification and regression tree (CART) analysis. The association between pharmacodynamic parameters (VAN AUC24/MICBMD, VAN AUC24/MICEtest, and AUC24/MBCBMD) and mortality were determined by χ2 and multivariable Poisson regression. Overall mortality in this cohort (n = 53) was 20.8% (n = 11/53), and all corresponding MRSA blood isolates were VAN susceptible (MIC range, 0.5 to 2 μg/ml; MIC50, 1 μg/ml; MIC90, 1 μg/ml). The CART-derived breakpoints for mortality were 176 (VAN AUC24/MBC) and 334 (VAN AUC24/MICBMD). In multivariable analysis, the association between a VAN AUC24/MBC of ≥176 and survival persisted, but VAN AUC24/MICBMD values (≥334 or ≥400) were not associated with improved mortality. In conclusion, VAN AUC24/MBC was a more important predictor of 30-day mortality than VAN AUC24/MIC for MRSA-B. PMID:26953202

  11. Food group diversity indicators derived from qualitative list-based questionnaire misreported some foods compared to same indicators derived from quantitative 24-hour recall in urban Burkina Faso.

    PubMed

    Martin-Prevel, Yves; Becquey, Elodie; Arimond, Mary

    2010-11-01

    To be useful proxies of micronutrient intake at the population level in resource-limited societies, dietary diversity indicators should be simple and easy to collect in large surveys and their accuracy needs to be assessed. The present study aimed at comparing food group diversity indicators (FGI) derived from simple qualitative list-based questionnaires (qFGI) to the same indicators derived from quantitative 24-h recalls (QFGI). Both methods were administered separately on each of 3 recall days to women in 2 districts of Ouagadougou, Burkina Faso. Data were available for a total of 526 women x recalls. This study was performed within the framework of the Women's Dietary Diversity Project, which sought to analyze the relationships between various QFGI and the mean probability of adequacy (MPA) of women's diets across 11 micronutrients. The comparison between paired qFGI and QFGI scores was made both in terms of accuracy of the reporting by the list-based questionnaire, taking the QFGI as the gold standard, and in terms of performance of indicators in predicting an MPA > 60%. Examination of paired QFGI-qFGI differences revealed that the more disaggregated the FGI, the higher were the mean differences in scores. Food groups most frequently misreported often corresponded to foods put in small quantities in sauces. Overreporting by list-based questionnaires was observed for indicators applying a 15-g minimum quantity of consumption for a group to count in the score and this may result in weaker performance in predicting the MPA. These results highlight trade-offs between accuracy and simplicity when operationalizing FGI through qualitative questionnaires.

  12. Vancomycin 24-Hour Area under the Curve/Minimum Bactericidal Concentration Ratio as a Novel Predictor of Mortality in Methicillin-Resistant Staphylococcus aureus Bacteremia.

    PubMed

    Britt, Nicholas S; Patel, Nimish; Horvat, Rebecca T; Steed, Molly E

    2016-05-01

    While previous studies have examined the association between vancomycin (VAN) exposure and MIC with regard to outcomes in methicillin-resistant Staphylococcus aureus bacteremia (MRSA-B), none have explored if a relationship exists with the VAN minimum bactericidal concentration (MBC). The objective of this study was to evaluate the VAN 24-h area under the curve (AUC24)/MBC ratio as a pharmacodynamic predictor of mortality. This retrospective cohort study included patients treated with VAN for MRSA-B with the primary outcome of 30-day all-cause mortality. Data collected included patient demographics, comorbidities, antimicrobial treatment data, therapeutic drug levels, and laboratory and microbiological data. Vancomycin MICs and MBCs were determined by Etest (MIC only) and broth microdilution (BMD). The vancomycin AUC24 was determined by pharmacokinetic maximum a posteriori probability Bayesian (MAP-Bayesian) analysis. The most significant breakpoint for 30-day mortality was determined by classification and regression tree (CART) analysis. The association between pharmacodynamic parameters (VAN AUC24/MICBMD, VAN AUC24/MICEtest, and AUC24/MBCBMD) and mortality were determined by χ(2) and multivariable Poisson regression. Overall mortality in this cohort (n = 53) was 20.8% (n = 11/53), and all corresponding MRSA blood isolates were VAN susceptible (MIC range, 0.5 to 2 μg/ml; MIC50, 1 μg/ml; MIC90, 1 μg/ml). The CART-derived breakpoints for mortality were 176 (VAN AUC24/MBC) and 334 (VAN AUC24/MICBMD). In multivariable analysis, the association between a VAN AUC24/MBC of ≥176 and survival persisted, but VAN AUC24/MICBMD values (≥334 or ≥400) were not associated with improved mortality. In conclusion, VAN AUC24/MBC was a more important predictor of 30-day mortality than VAN AUC24/MIC for MRSA-B. PMID:26953202

  13. The urine albumin-to-creatinine ratio is a reliable indicator for evaluating complications of chronic kidney disease and progression in IgA nephropathy in China

    PubMed Central

    Huan, Lu; Yuezhong, Luo; Chao, Wang; HaiTao, Tu

    2016-01-01

    OBJECTIVE: This study investigated the correlation between the albumin-to-creatinine ratio in the urine and 24-hour urine proteinuria and whether the ratio can predict chronic kidney disease progression even more reliably than 24-hour proteinuria can, particularly in primary IgA nephropathy. METHODS: A total of 182 patients with primary IgA nephropathy were evaluated. Their mean urine albumin-to-creatinine ratio and 24-hour proteinuria were determined during hospitalization. Blood samples were also analyzed. Follow-up data were recorded for 44 patients. A cross-sectional study was then conducted to test the correlation between these parameters and their associations with chronic kidney disease complications. Subsequently, a canonical correlation analysis was employed to assess the correlation between baseline proteinuria and parameters of the Oxford classification. Finally, a prospective observational study was performed to evaluate the association between proteinuria and clinical outcomes. Our study is registered in the Chinese Clinical Trial Registry, and the registration number is ChiCTR-OCH-14005137. RESULTS: A strong correlation (r=0.81, p<0.001) was found between the ratio and 24-hour proteinuria except in chronic kidney disease stage 5. First-morning urine albumin-to-creatinine ratios of ≥125.15, 154.44 and 760.31 mg/g reliably predicted equivalent 24-hour proteinuria ‘thresholds’ of ≥0.15, 0.3 and 1.0 g/24 h, respectively. In continuous analyses, the albumin-to-creatinine ratio was significantly associated with anemia, acidosis, hypoalbuminemia, hyperphosphatemia, hyperkalemia, hypercholesterolemia and higher serum cystatin C. However, higher 24-hour proteinuria was only associated with hypoalbuminemia and hypercholesterolemia. Higher tubular atrophy and interstitial fibrosis scores were also associated with a greater albumin-to-creatinine ratio, as observed in the canonical correlation analysis. Finally, the albumin-to-creatinine ratio and 24-hour

  14. 75 FR 67382 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, OMB No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-02

    ... Structure Amendments to National Flood Insurance Program Maps (Spanish). SUMMARY: The Federal Emergency... Flood Insurance Program Maps (Spanish). Abstract: This collection of information allows owners of... hours), FEMA Form 086-0-22 English (2.4 hours), FEMA Form 086-0- 22A Spanish (2.4 hours)....

  15. Urination - excessive amount

    MedlinePlus

    ... done include: Blood sugar (glucose) test Blood urea nitrogen test Creatinine (serum) Electrolytes (serum) Fluid deprivation test (limiting fluids to see if the urine volume decreases) Osmolality blood test Urinalysis Urine osmolality test

  16. RBC urine test

    MedlinePlus

    Red blood cells in urine; Hematuria test; Urine - red blood cells ... A normal result is 4 red blood cells per high power field (RBC/HPF) or less when the sample is examined under a microscope. The example above ...

  17. Urine drainage bags

    MedlinePlus

    ... catheter and urine drainage bag because you have urinary incontinence (leakage), urinary retention (not being able to urinate), ... wall repair Inflatable artificial sphincter Radical prostatectomy Stress urinary incontinence Urge incontinence Urinary incontinence Urinary incontinence - injectable implant ...

  18. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...-specimen methods of collection. (b) If the urine specimen is to be split into two specimen bottles, hereinafter referred to as Bottle A and Bottle B, the collector shall take the following steps: (1) The... urine specimen. The collector shall pour 30 mL of urine into Bottle A and a minimum of 15 mL of...

  19. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy... Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split-specimen methods of collection. (b) If the urine specimen is to be split into two specimen...

  20. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy... Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split-specimen methods of collection. (b) If the urine specimen is to be split into two specimen...

  1. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy... Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use split-specimen methods of collection. (b) If the urine specimen is to be split into two specimen...

  2. 24-hour urinary aldosterone excretion test

    MedlinePlus

    Gruber HA, Farag AF. Evaluation of endocrine function. In: McPherson RA, Pincus MR, eds. Henry's Clinical Diagnosis and Management by Laboratory Methods . 22nd ed. Philadelphia, PA: Elsevier Saunders; 2011:chap 24.

  3. Toys Remain Viral Playground for 24 Hours

    MedlinePlus

    ... a toy's surface at typical indoor temperatures and humidity levels. Specifically, they tested the ability of so- ... East Respiratory Syndrome (MERS). At 60 percent relative humidity, 1 percent of the virus remained infectious on ...

  4. Urine pH test

    MedlinePlus

    A urine pH test measures the level of acid in urine. ... pH - urine ... meat products, or cheese can decrease your urine pH. ... to check for changes in your urine acid levels. It may be done to ... more effective when urine is acidic or non-acidic (alkaline).

  5. Novel description of the 24-hour circadian rhythms of brachial versus central aortic blood pressure and the impact of blood pressure treatment in a randomized controlled clinical trial: The Ambulatory Central Aortic Pressure (AmCAP) Study.

    PubMed

    Williams, Bryan; Lacy, Peter S; Baschiera, Fabio; Brunel, Patrick; Düsing, Rainer

    2013-06-01

    Elevated brachial blood pressure (BP) is associated with increased cardiovascular risk and predicts morbidity and mortality in humans. Recently, 24-hour ambulatory BP monitoring and assessment of central aortic BP have been introduced to improve BP phenotyping. The Ambulatory Central Aortic Pressure (AmCAP) study combines these approaches and describes, for the first time, the diurnal patterns of simultaneously measured 24-hour ambulatory brachial and central pressures in a prespecified substudy embedded within a clinical trial of BP lowering in patients with hypertension. Twenty-four-hour ambulatory brachial and central pressure measurements were acquired using a tonometer mounted into the articulating strap of a wristwatch-like device (BPro) in 171 participants with hypertension recruited into the ASSERTIVE (AliSkiren Study of profound antihypERtensive efficacy in hyperTensIVE patients) trial. Participants were randomly assigned to BP lowering with either aliskiren 300 mg QD or telmisartan 80 mg QD for 12 weeks. Ambulatory brachial and central BP was measured in all participants both at baseline and at study end. Brachial and central BP both demonstrated typical diurnal patterns with lower pressures at night. However, night time was associated with smaller reductions in central relative to brachial pressure and decreased pulse pressure amplification (P<0.0001 for both). These effects were not modulated after BP lowering and were maintained after adjustment for day and night-time BP and heart rate (P=0.02). This study demonstrates that brachial and central pressure show different diurnal patterns, which are not modulated by BP-lowering therapy, with relatively higher night-time central pressures. These novel data indicate that night-time central BP may provide prognostic importance and warrants further investigation. Clinical Trial Registration- URL: http://www.clinicaltrials.gov. Unique identifier: NCT00865020. PMID:23630950

  6. Mutagenicity studies with urine concentrates from coke plant workers

    SciTech Connect

    Moeller, M.; Dybing, E.

    1980-01-01

    Urine from coke plant workers, collected before and after work, were tested for the content of mutagenic substances in the Salmonella test system. Urine extracts from exposed smokers showed mutagenic activity, whereas urine from exposed nonsmokers did not. The mutagenicity of exposed smoker's urine was not significantly different from that of urine from nonexposed smokers. Mutagenicity of smokers' urine was only evident in the presence of a rat liver metabolic activation system. The addition of beta-glucuronidase did not enhance the mutagenic effect. The facts that coke plant workers are exposed to very high levels of polycyclic aromatic hydrocarbons (PAH) and that there is no observed enhanced mutagenicity of their urine indicate that the mutagenicity observed with urine from smokers is not due to conventional PAH.

  7. Serum, Saliva, and Urine Irisin with and Without Acute Appendicitis and Abdominal Pain

    PubMed Central

    Bakal, Unal; Aydin, Suleyman; Sarac, Mehmet; Kuloglu, Tuncay; Kalayci, Mehmet; Artas, Gokhan; Yardim, Meltem; Kazez, Ahmet

    2016-01-01

    A 112-amino-acid protein irisin (IRI) is widely expressed in many organs, but we currently do not know whether appendix tissue and blood cells express it. If appendix tissue and neutrophil cells express IRI, measuring its concentration in biological fluids might be helpful in the diagnosis of acute appendicitis (AA), since neutrophil cells are the currently gold-standard laboratory parameters for the diagnosis of AA. Therefore, the purpose of this study was to investigate the suitability of enzyme-linked immunosorbent assay-based measurements of the proposed myokine IRI for the discrimination of patients with AA from those with acute abdominal pain (AP) and healthy controls. Moreover, immunoreactivity to IRI was investigated in appendix tissues and blood cells. Samples were collected on admission (T1), 24 hours (T2), and 72 hours (T3) postoperatively from patients with suspected AA and from patients with AP corresponding to T1–T3, whereas control subject blood was once corresponding to T1. IRI was measured in serum, saliva, and urine by using enzyme-linked immunosorbent assay, whereas in appendix tissue and blood cells, IRI was detected by immunohistohcemistry. Appendix tissue and blood cells (except for erythrocytes) are new sources of IRI. Basal saliva, urine, and serum levels were higher in children with AA compared with postoperative levels (T2) that start to decline after surgery. This is in line with the finding that IRI levels are higher in children with AA when compared with those with AP or control subject levels, most likely due to a large infiltration of neutrophil cells in AA that release its IRI into body fluids. Measurement of IRI in children with AA parallels the increase or decrease in the neutrophil count. This new finding shows that the measurement of IRI and neutrophil count can together improve the diagnosis of AA, and it can distinguish it from AP. IRI can be a candidate marker for the diagnosis of AA and offers an additional parameter to

  8. Osmolality urine - series (image)

    MedlinePlus

    ... midstream) urine sample. To obtain a clean-catch sample, men or boys should wipe clean the head of the penis. Women or girls need to wash the area between the lips of the vagina with soapy water and rinse well. As you start to urinate, ...

  9. The Relationship of the Increase in the 'Time of the Earth Day,' from 18 Hours to 24 Hours, to the Increase in the Size of the Earth, Using the Laws of the Conservation of Momentum

    NASA Astrophysics Data System (ADS)

    Cimorelli, S. A.; Samuels, C.

    2010-12-01

    There are three articles, by others, which discuss the increase in the Earth's day, from 18 hours to 24 hours, over a period of time of about a billion years. One article refers to Striations in the Substructure of Coral, C.T. Scrutton, et al, 1965. Another article refers to the Laws of the Conservation of Momentum, as related to the relationship of the Earth and the Moon, the lunar tides, the reduction of the Earth year from 481 days to our present 365.25 days, and an increase in the lunar orbit time from 20 days to 28 days. The third article is based on the dates of tidal sediment deposits, tidalites, C. P. Sonett, et al, in the late 1980's. In this paper, we explain how the Earth's Day could have increased from 18 hours to 24 hours, as related to the Laws of Conservation of Momentum (L). Wherein we use the simple formulation from the Law of the Conservation of Angular Momentum, L=Iω, in which I=Moment of Inertia and ω=Angular Velocity; for which we assume the earth to be a perfect sphere, for which I=0.4MR2, where M and R are the Mass and radius of the earth, respectively. We evaluate the radius of the earth over a time period of several billion years, during which time the earth's angular momentum, L=Iω, is conserved. In this formulation, we show a growth in the size of the earth; and present a curve, using just three points in time, which indicates that the rate of growth is increasing over time. The first point is from about 4.5 billion years ago, the second point is from about 1 billion years ago, and the third point represents present day, with an average growth of about 1mm per year. Although evidence has been presented, by others, showing circumferential growth at the Red Sea and in the Atlantic Ocean, at about 1.5cm per year, total. However, no proof of reduction in the size of the Earth has been shown to occur in the Pacific, or anywhere else, including in references to subduction. Some might say that the subduction is occurring at the rim of the

  10. β3-Adrenoreceptors in the thick ascending limb of Henle and in principal cells of the collecting duct work to concentrate urine.

    PubMed

    Bichet, Daniel G

    2016-09-01

    β3-Adrenoreceptors and their importance to increase sodium reabsorption in the thick ascending loop of Henle and to increase water reabsorption in principal cells of the collecting duct are, for the first time, described here. This is an integrated brain response to dehydration perceived by osmosensitive cells in the hypothalamus and triggering through vasopressin axonal and dendritic release a coordinated response implicating vasopressin V2 receptors and β3-adrenoreceptors on the luminal membrane of cortical collecting duct cells. PMID:27521107

  11. Deoxypyridinoline in the Urine of Rats with Unloaded Hindlimbs

    NASA Technical Reports Server (NTRS)

    Arnaud, Sara B.; Navidi, M.; Wren, J.; Holton, Emily M. (Technical Monitor)

    1997-01-01

    The urinary excretion of deoxypyridinoline (U-Dpd), a nonreducible collagen crosslink in bone released by osteoclastic activity, is thought to be an accurate marker of bone resorption. The role of increased resorption in the osteopenia of a space flight model which unloads the hindlimbs by suspending the tail is controversial. To assess skeletal resorption in the model we measured U-Dpd (Pyrilinks-D, Metro Biosystems, Inc.) in serial 24 hour urine specimens collected from 250 a (Y) and 450 a (M) male rats with unloaded hindlimbs for four weeks. Both groups of rats were fed AIN76 diets with calcium restricted to 0.2% in Y and to 0.1 % in M. Blood was obtained after 28 days for parathyroid hormone (PTH), 1,25-dihydroxyvitamin D (1,25-D) and alkaline phosphatase (Alkptase). Basal U-Dpd was higher and more variable in Y than M (475+/-200 vs 67+/-9, nM/mM creatinine, p<.001). Repeated measures ANOVA in Y revealed decreases in U-Dpd, 36% in control (C) and 24% in unloaded (S) rats (p<.005). There was a nadir in YS on the 14th day not observed in YC (p<.05). U-Dpd in MC showed no change, but increased in MS by the 14th day and remained elevated. At the end of the experiment, body weights in both Y and M were less in S than C (337+/-16 vs 306+/-12g and 485+/-10 vs 461+/-6g, p=.002). Bill was inversely related to U-Dpd only in M (r=0.699, p=.024). PTH, similar in C and S in Y (52+/-15 vs 42+/-7pg/ml, NS) and M (68+/-13 vs 61+/-12, NS), was unrelated to U-Dpd. 1,25-D tended toward higher values in YC than YS (197+/-103 vs 119+/-30, NS) and correlated with U-Dpd (0.773, p=.015). Alkptase, 1.3 times higher in Y than M, was similar in C and S at the end of unloading. These findings indicate that bone resorption, as reflected by U-Dpd, is suppressed in young and stimulated in mature rats exposed to a space flight model. U-Dpd reflects reduced growth from the diet change in young control and experimental rats and loss of Bill in mature animals exposed to the space flight model, 2

  12. Forgotten hardware: how to urinate in a spacesuit.

    PubMed

    Hollins, Hunter

    2013-06-01

    On May 5, 1961, astronaut Alan Shepard became the first American to fly in space. Although National Aeronautics and Space Administration (NASA) had discounted the need for him to urinate, Shepard did, in his spacesuit, short circuiting his electronic biosensors. With the development of the pressure suit needed for high-altitude and space flight during the 1950s, technicians had developed the means for urine collection. However, cultural mores, combined with a lack of interagency communication, and the technical difficulties of spaceflight made human waste collection a difficult task. Despite the difficulties, technicians at NASA created a successful urine collection device that John Glenn wore on the first Mercury orbital flight on February 20, 1962. With minor modifications, male astronauts used this system to collect urine until the Space Shuttle program. John Glenn's urine collection device is at the National Air and Space Museum and has been on view to the public since 1976. PMID:23728129

  13. Forgotten hardware: how to urinate in a spacesuit.

    PubMed

    Hollins, Hunter

    2013-06-01

    On May 5, 1961, astronaut Alan Shepard became the first American to fly in space. Although National Aeronautics and Space Administration (NASA) had discounted the need for him to urinate, Shepard did, in his spacesuit, short circuiting his electronic biosensors. With the development of the pressure suit needed for high-altitude and space flight during the 1950s, technicians had developed the means for urine collection. However, cultural mores, combined with a lack of interagency communication, and the technical difficulties of spaceflight made human waste collection a difficult task. Despite the difficulties, technicians at NASA created a successful urine collection device that John Glenn wore on the first Mercury orbital flight on February 20, 1962. With minor modifications, male astronauts used this system to collect urine until the Space Shuttle program. John Glenn's urine collection device is at the National Air and Space Museum and has been on view to the public since 1976.

  14. Effective cross-over to granisetron after failure to ondansetron, a randomized double blind study in patients failing ondansetron plus dexamethasone during the first 24 hours following highly emetogenic chemotherapy

    PubMed Central

    de Wit, R; de Boer, A C; vd Linden, G H M; Stoter, G; Sparreboom, A; Verweij, J

    2001-01-01

    In view of the similarity in chemical structure of the available 5HT3-receptor antagonists it is assumed, whilst these agents all act at the same receptor, that failure to one agent would predict subsequent failure to all 5HT3-receptor antagonists. We conducted a randomized double blind trial of granisetron 3 mg plus dexamethasone 10 mg versus continued treatment with ondansetron 8 mg plus dexamethasone 10 mg in patients with protection failure on ondansetron 8 mg plus dexamethasone 10 mg during the first 24 hours following highly emetogenic chemotherapy. Of 40 eligible patients, 21 received ondansetron + dexamethasone and 19 received granisetron + dexamethasone. We found a significant benefit from crossing-over to granisetron after failure on ondansetron. Of the 19 patients who crossed over to granisetron, 9 patients obtained complete protection, whereas this was observed in 1 of the 21 patients continuing ondansetron, P = 0.005. These results indicate that there is no complete cross-resistance between 5HT3-receptor antagonists, and that patients who have acute protection failure on one 5HT3-receptor antagonist should be offered cross-over to another 5HT3-receptor antagonist. © 2001 Cancer Research Campaign  http://www.bjcancer.com PMID:11710819

  15. Diagnosis and effects of urine contamination in cooled-extended stallion semen.

    PubMed

    Ellerbrock, R; Canisso, I; Feijo, L; Lima, F; Shipley, C; Kline, K

    2016-04-15

    Urospermia is known to affect semen quality in many mammals, including stallions. Determinations of semen pH and creatinine and urea concentrations have been used to diagnose urine contamination in raw stallion semen. Unfortunately, practitioners suspecting urine contamination in cooled-shipped samples have no proven means to confirm the presence of urine. Therefore, the objectives of this study were (1) to assess the effects of urine contamination on sperm motility of extended fresh and cooled-stored stallion semen, (2) to evaluate the usefulness of semen color, odor, pH, and creatinine and urea concentrations for urospermia diagnosis, and (3) to evaluate the accuracy of a commercial blood urea nitrogen test strip in diagnosing urine contamination in extended-cooled stallion semen. Thirty-seven ejaculates were obtained from 11 stallions with no history of urospermia before division into 5 mL aliquots, and contamination with stallion urine. Each resulting sample was assessed for sperm motility, color, odor, pH, creatinine, and urea nitrogen concentration using both a semiquantitative test strip (Azostix), and a quantitative automated analyzer before and after cooling for 24 hour. Sperm motility parameters, pH, and creatinine and urea concentrations were analyzed using mixed models. Urine contamination decreased total and progressive motility in all samples before and after cooling (P < 0.05). Mean control total motility was 80% at 0 hour and 67% at 24 hours, whereas urine-contaminated samples ranged from 30% to 71% at 0 hour and 27% to 61% at 24 hours. Control mean urea (29 mg/dL) and creatinine (0.6 mg/dL) concentrations were significantly different (P < 0.05) from all urine-contaminated samples (158 mg/dL and 11.6 mg/dL, respectively) at 0 hour. Similarly, control mean urea (8 mg/dL) and creatinine (0.9 mg/dL) concentrations were significantly different than all urine-contaminated samples at 24 hours. Odor assessment presented moderate sensitivity (65

  16. Urine output - decreased

    MedlinePlus

    ... include: Abdominal ultrasound Blood tests for electrolytes , kidney function, and blood count CT scan of the abdomen (done without contrast dye if your kidney function is impaired) Renal scan Urine tests, including tests ...

  17. Urinating more at night

    MedlinePlus

    ... in the past? Do you have a family history of diabetes ? Does nighttime urination interfere with your sleep? Tests that may be performed include: Blood sugar (glucose) Blood urea nitrogen Fluid deprivation Osmolality , blood Serum creatinine or creatinine ...

  18. PBG urine test

    MedlinePlus

    Porphobilinogen test ... temporarily stop taking medicines that may affect the test results. Be sure to tell your provider about ... This test involves only normal urination, and there is no discomfort.

  19. Effects of Verapamil SR and Atenolol on 24-Hour Blood Pressure and Heart Rate in Hypertension Patients with Coronary Artery Disease: An International Verapamil SR-Trandolapril Ambulatory Monitoring Substudy

    PubMed Central

    Denardo, Scott J.; Gong, Yan; Cooper-DeHoff, Rhonda M.; Farsang, Csaba; Keltai, Matyas; Szirmai, László; Messerli, Franz H.; Bavry, Anthony A.; Handberg, Eileen M.; Mancia, Giuseppe; Pepine, Carl J.

    2015-01-01

    Elevated nighttime blood pressure (BP) and heart rate (HR), increased BP and HR variability, and altered diurnal variations of BP and HR (nighttime dipping and morning surge) in patients with systemic hypertension are each associated with increased adverse cardiovascular events. However, there are no reports on the effect of hypertension treatment on these important hemodynamic parameters in the growing population of hypertensive patients with atherosclerotic coronary artery disease (CAD). This was a pre-specified subgroup analysis of the INternational VErapamil SR-Trandolapril STudy (INVEST), which involved 22,576 clinically stable patients aged ≥50 years with hypertension and CAD randomized to either verapamil SR- or atenolol-based hypertension treatment strategies. The subgroup consisted of 117 patients undergoing 24-hour ambulatory monitoring at baseline and after 1 year of treatment. Hourly systolic and diastolic BP (SBP and DBP) decreased after 1 year for both verapamil SR- and atenolol-based treatment strategies compared with baseline (P<0.0001). Atenolol also decreased hourly HR (P<0.0001). Both treatment strategies decreased SBP variability (weighted standard deviation: P = 0.012 and 0.021, respectively). Compared with verapamil SR, atenolol also increased the prevalence of BP and HR nighttime dipping among prior non-dippers (BP: OR = 3.37; 95% CI: 1.26 – 8.97; P = 0.015; HR: OR = 4.06; 95% CI: 1.35-12.17; P = 0.012) and blunted HR morning surge (+2.8 vs. +4.5 beats/min/hr; P = 0.019). Both verapamil SR- and especially atenolol-based strategies resulted in favorable changes in ambulatory monitoring parameters that have been previously associated with increased adverse cardiovascular events. Trial Registration Clinicaltrials.gov; NCT00133692 PMID:25835002

  20. Comparison of validity of food group intake by food frequency questionnaire between pre- and post- adjustment estimates derived from 2-day 24-hour recalls in combination with the probability of consumption.

    PubMed

    Kim, Dong Woo; Oh, Se-Young; Kwon, Sung-Ok; Kim, Jeongseon

    2012-01-01

    Validation of a food frequency questionnaire (FFQ) utilising a short-term measurement method is challenging when the reference method does not accurately reflect the usual food intake. In addition, food group intake that is not consumed on daily basis is more critical when episodically consumed foods are related and compared. To overcome these challenges, several statistical approaches have been developed to determine usual food intake distributions. The Multiple Source Method (MSM) can calculate the usual food intake by combining the frequency questions of an FFQ with the short-term food intake amount data. In this study, we applied the MSM to estimate the usual food group intake and evaluate the validity of an FFQ with a group of 333 Korean children (aged 3-6 y) who completed two 24-hour recalls (24HR) and one FFQ in 2010. After adjusting the data using the MSM procedure, the true rate of non-consumption for all food groups was less than 1% except for the beans group. The median Spearman correlation coefficients against FFQ of the mean of 2-d 24HRs data and the MSM-adjusted data were 0.20 (range: 0.11 to 0.40) and 0.35 (range: 0.14 to 0.60), respectively. The weighted kappa values against FFQ ranged from 0.08 to 0.25 for the mean of 2-d 24HRs data and from 0.10 to 0.41 for the MSM-adjusted data. For most food groups, the MSM-adjusted data showed relatively stronger correlations against FFQ than raw 2-d 24HRs data, from 0.03 (beverages) to 0.34 (mushrooms). The results of this study indicated that the application of the MSM, which was a better estimate of the usual intake, could be worth considering in FFQ validation studies among Korean children.

  1. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  2. Human Urine as a Noninvasive Source of Kidney Cells.

    PubMed

    Oliveira Arcolino, Fanny; Tort Piella, Agnès; Papadimitriou, Elli; Bussolati, Benedetta; Antonie, Daniel J; Murray, Patricia; van den Heuvel, Lamberthus; Levtchenko, Elena

    2015-01-01

    Urine represents an unlimited source of patient-specific kidney cells that can be harvested noninvasively. Urine derived podocytes and proximal tubule cells have been used to study disease mechanisms and to screen for novel drug therapies in a variety of human kidney disorders. The urinary kidney stem/progenitor cells and extracellular vesicles, instead, might be promising for therapeutic treatments of kidney injury. The greatest advantages of urine as a source of viable cells are the easy collection and less complicated ethical issues. However, extensive characterization and in vivo studies still have to be performed before the clinical use of urine-derived kidney progenitors. PMID:26089913

  3. Use of urine in snow to indicate condition of wolves

    USGS Publications Warehouse

    Mech, L.D.; Seal, U.S.; DelGiudice, G.D.

    1987-01-01

    Urine deposited in snow by wild gray wolves (Canis lupus) and by fed and fasted captive wolves was analyzed for urea nitrogen, calcium, sodium, potassium, and creatinine. Ratios of the elements with creatinine were considerably higher for fed than for fasted animals, and ratios for fed wolves compared favorably with ratios from wolf urine in snow along trails leading from kills. Thus, wolf urine in the snow can indicate whether wolves have fed recently, and a series of such urine collections from any given pack can indicate relative nutritional state.

  4. Human Urine as a Noninvasive Source of Kidney Cells

    PubMed Central

    Oliveira Arcolino, Fanny; Tort Piella, Agnès; Papadimitriou, Elli; Bussolati, Benedetta; Antonie, Daniel J.; Murray, Patricia; van den Heuvel, Lamberthus; Levtchenko, Elena

    2015-01-01

    Urine represents an unlimited source of patient-specific kidney cells that can be harvested noninvasively. Urine derived podocytes and proximal tubule cells have been used to study disease mechanisms and to screen for novel drug therapies in a variety of human kidney disorders. The urinary kidney stem/progenitor cells and extracellular vesicles, instead, might be promising for therapeutic treatments of kidney injury. The greatest advantages of urine as a source of viable cells are the easy collection and less complicated ethical issues. However, extensive characterization and in vivo studies still have to be performed before the clinical use of urine-derived kidney progenitors. PMID:26089913

  5. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  6. 10 CFR 26.109 - Urine specimen quantity.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Urine specimen quantity. 26.109 Section 26.109 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.109 Urine specimen quantity. (a) Licensees and other entities who are subject to this subpart shall establish...

  7. 10 CFR 26.113 - Splitting the urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Splitting the urine specimen. 26.113 Section 26.113 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.113 Splitting the urine specimen. (a) Licensees and other entities may, but are not required to, use...

  8. 78 FR 14402 - Agency Information Collection Activities; Extension of a Currently Approved Collection: Driver...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-05

    ... December 29, 2010 (75 FR 82133). Public Participation: The Federal eRulemaking Portal is available 24 hours... Federal Motor Carrier Safety Administration Agency Information Collection Activities; Extension of a... Reduction Act of 1995, FMCSA announces its plan to submit the Information Collection Request (ICR)...

  9. The otolaryngologic manifestations of gastroesophageal reflux disease (GERD): a clinical investigation of 225 patients using ambulatory 24-hour pH monitoring and an experimental investigation of the role of acid and pepsin in the development of laryngeal injury.

    PubMed

    Koufman, J A

    1991-04-01

    Occult (silent) gastroesophageal reflux disease (GER, GERD) is believed to be an important etiologic factor in the development of many inflammatory and neoplastic disorders of the upper aerodigestive tract. In order ot test this hypothesis, a human study and an animal study were performed. The human study consisted primarily of applying a new diagnostic technique (double-probe pH monitoring) to a population of otolaryngology patients with GERD to determine the incidence of overt and occult GERD. The animal study consisted of experiments to evaluate the potential damaging effects of intermittent GER on the larynx. Two hundred twenty-five consecutive patients with otolaryngologic disorders having suspected GERD evaluated from 1985 through 1988 are reported. Ambulatory 24-hour intraesophageal pH monitoring was performed in 197; of those, 81% underwent double-probe pH monitoring, with the second pH probe being placed in the hypopharynx at the laryngeal inlet. Seventy percent of the patients also underwent barium esophagography with videofluoroscopy. The patient population was divided into seven diagnostic subgroups: carcinoma of the larynx (n = 31), laryngeal and tracheal stenosis (n = 33), reflux laryngitis (n = 61), globus pharyngeus (n = 27), dysphagia (n = 25), chronic cough (n = 30), and a group with miscellaneous disorders (n = 18). The most common symptoms were hoarseness (71%), cough (51%), globus (47%), and throat clearing (42%). Only 43% of the patients had gastrointestinal symptoms (heartburn or acid regurgitation). Thus, by traditional symptomatology, GER was occult or silent in the majority of the study population. Twenty-eight patients (12%) refused or could not tolerate pH monitoring. Of the patients undergoing diagnostic pH monitoring, 62% had abnormal esophageal pH studies, and 30% demonstrated reflux into the pharynx. The results of diagnostic pH monitoring for each of the subgroups were as follows (percentage with abnormal studies): carcinoma (71

  10. Application of urine mutagenicity to monitor coal liquefaction workers.

    PubMed

    Recio, L; Enoch, H G; Hannan, M A; Hill, R H

    1984-06-01

    The Salmonella/microsomal assay was used to monitor workers' urine for mutagenicity as a potential indicator of human exposure to mutagens/carcinogens. Urine samples from 57 workers at a coal liquefaction pilot plant in Catlettsburg, Kentucky, were assayed for mutagenicity during work periods. Urine samples were collected twice during plant operations and once when the individuals were away from the plant for at least 48 h. In 7 individual smokers (5 operator/maintenance workers and 2 administrative staff workers) there was an indication of enhanced urine mutagenicity during work periods. Urine mutagenicity of nonsmokers from the pilot plant was significantly higher than that of an additional control group of nonsmokers from Lexington, Kentucky. While cigarette smoking was the major factor affecting urine mutagenicity, no significant mutagenicity that could be directly attributed to the pilot plant workers' environment was evident.

  11. The Human Urine Metabolome

    PubMed Central

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing

  12. False positivity of gamma-glutamyl transpeptidase measurement in urine.

    PubMed

    Crivellenti, Leandro Zuccolotto; Mesa, Javier Sousa; Meirelles, Adriana Érica Wilkes Burton; Borin Crivellenti, Sofia; Mireya, Edna Gomes; Canola, Julio Carlos; Hatayde, Mário Roberto; Santana, Aureo Evangelista; Dantas, Márcio; Silva, Gyl Eanes Barros

    2014-05-01

    Although enzymuria tends to be associated to renal injury, there are no studies that have evaluated the presence of the enzyme gamma-glutamyl transpeptidase (GGT) spectrophotometry in the urine using a non-nephrotoxic agent (Nerium oleander) in order to evaluate the possibility of false positive results. The urinary GGT/urinary creatinine concentration ratio (uGGT/uCr) of 10 healthy dogs was calculated and posteriorly confronted with data from clinical evaluation, hematological and serum biochemical profiles, creatinine clearance (CrC), urinalysis, urine protein/creatinine ratio (UPC), electrocardiogram, systemic blood pressure (SBP) and light and electron microscopy. The results for kidney histology, SBP, UPC and CrC were not significantly different in any of the time-points analyzed. However, uGGT/uCr was significantly higher when measured 4 hours and 24 hours after administration of N. oleander. The measurement of the urinary GGT enzyme, as performed in many studies, yielded false positive results in dogs poisoned by a non-nephrotoxic agent.

  13. Taurine in morning spot urine for the useful assessment of dietary seafood intake in Japanese children and adolescents

    PubMed Central

    2010-01-01

    Background Since our previous report on WHO CARDIAC Study data demonstrated that 24-hour urinary (24U) taurine (Tau) excretion was a useful biomarker of seafood (SF) intake and inversely related to the mortality rates of stroke and coronary heart diseases in the world, we determined that SF is important in the risk reduction of lifestyle related-diseases. The amounts of dietary SF intake are so far estimated from a nutritional survey or 24U Tau excretion. The sodium/potassium ratio of spot urine (SU) and the 24U ratio were reported to be significantly correlated with. Therefore, we presently examined the relationship of Tau excretion in the morning SU with 24U Tau for simplifying the population comparison and the follow-up of SF intake changes in the process of food education program (FEP). Methods After informed consent was obtained, 54 children aged 6-11 years (Children) and 193 adolescents aged 13-18 years (Adolescents) participated in collecting precisely 24U and SU of the first urination on the same day and answered the questionnaire including age and height and weight measurements. The urine samples were measured for creatinine (Cre) and Tau, and the association of these between 24U and SU were analyzed. Results The success rates of 24U sampling were very high in Children and Adolescents, 96.4% and 82.4%, respectively. From the result of the multiple regression analysis of SU Tau/Cre and weight we obtained formulas for predicting 24U Tau excretion in Children and Adolescents as follows: Children: 24U Tau = 16.3 (weight) + 314.3 (SU Tau/Cre) -175.2; and Adolescents: 24U Tau = 20.2 (weight) + 644.7 (SU Tau/Cre) - 569.4. Conclusions The present study established the regression equation to estimate 24U Tau excretion from SU Tau/Cre and weight. These formulas are expected to contribute to the estimation of fish and SF intake and the follow-up of the change of the dietary behavior by FEP in Children and Adolescents. PMID:20804620

  14. Color recognition system for urine analyzer

    NASA Astrophysics Data System (ADS)

    Zhu, Lianqing; Wang, Zicai; Lin, Qian; Dong, Mingli

    2010-08-01

    In order to increase the speed of photoelectric conversion, a linear CCD is applied as the photoelectric converter instead of the traditional photodiode. A white LED is used as the light source of the system. The color information of the urine test strip is transferred into the CCD through a reflecting optical system. It is then converted to digital signals by an A/D converter. The test results of urine analysis are obtained by a data processing system. An ARM microprocessor is selected as the CPU of the system and a CPLD is employed to provide a driving timing for the CCD drive and the A/D converter. Active HDL7.2 and Verilog HDL are used to simulate the driving timing of the CPLD. Experimental results show that the correctness rate of the test results is better than 90%. The system satisfies the requirements of the color information collection of urine analyzer.

  15. Advanced urine toxicology testing.

    PubMed

    Tenore, Peter L

    2010-10-01

    Urine toxicology screening testing is an important standard of care in the addiction and pain treatment setting, offering a reproducible, unbiased, and accurate laboratory test to monitor patients and provide objective support for clinical observations. It has been shown that physicians do not have proficiency in the ordering or interpretation of these tests. This article is an attempt to respond to that need. Current antibody-based enzymatic immunoassays (EIAs) used for urine toxicology screening are useful to detect classes of drugs (ex., opiate) but cannot determine which specific drug (ex., morphine) is present. Gas chromatography and mass spectroscopy can determine exactly which drugs are present, allowing prescribed (or illicit) opiates and benzodiazepines to be identified. This article will discuss principles and details of opiate and benzodiazepine EIA and gas chromatography and mass spectroscopy urine toxicology testing. The approach to detecting patients attributing positive opiate EIAs to prescription opiates who are using heroin or other opioids will be reviewed. Cases of controlled prescription drugs that do not produce the expected positive urine tests (ex., oxycodone producing negative opiate screening tests) will be discussed. How to differentiate codeine from heroin and the role of poppy seeds in toxicology will be examined. The case of an anti-depressant drug that produces false-positive benzodiazepine results and antibiotics that cause positive opiate urine toxicology results will be reviewed. Common benzodiazepines (ex., clonazepam and lorazepam) that do not reliably produce positive benzodiazepine EIAs will be discussed. The approach to detection and management of all these types of toxicology cases will be reviewed, and it is hoped that the analyses presented will impart an adequate information base to medical providers and staff members of drug treatment and pain centers, enabling them to order and interpret these tests in the clinic more

  16. Blood in the Urine (Hematuria)

    MedlinePlus

    ... process starts in the kidneys , which remove excess fluids and waste from the blood and turn them into urine. The urine then flows through tubes called ureters into the bladder, where it's stored ...

  17. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  18. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  19. Chemical composition of rainbow trout urine following acute hypoxic stress

    USGS Publications Warehouse

    Hunn, Joseph B.

    1969-01-01

    Rainbow trout (Salmo gairdnerii) were anesthetized with MS-222, catheterized, and introduced into urine collecting chambers. Twenty-four hours after introduction, a 4-hour accumulation of urine was collected to serve as the control. Water flow to the chambers was then discontinued for 30 minutes during which the oxygen content of the water exiting in the chamber dropped from 4.9 to 2.8 mg/l. Following this hypoxic stress fresh water was restored and accumulated urine samples were taken for analysis at 1, 4, and 20 hours post-hypoxic stress. Rainbow trout excrete abnormally high concentrations of Na, K, Mg, Cl, and inorganic PO4 following hypoxia.

  20. CT-determined canine kidney and urine iodine concentration following intravenous administration of sodium diatrizoate, metrizamide, iopamidol, and sodium ioxaglate.

    PubMed

    Brennan, R E; Rapoport, S; Weinberg, I; Pollack, H M; Curtis, J A

    1982-01-01

    Following 24-hour fasting and fluid deprivation, sequential changes in CT numbers of the canine kidney were determined in 4 dogs, each of whom received, at intervals, IV sodium diatrizoate, metrizamide, iopamidol, and sodium ioxaglate at a dose of 500 mgI/kg body weight. The urinary bladder was catheterized for baseline determination of urine osmolality and, subsequently, urine volume and CT number, CT number of the bladder urine from 0 to 10 minutes and from 10 to 20 minutes post-injection was obtained by scanning known dilutions of urine in vitro. Peak renal cortical enhancement occurred within 2 minutes of bolus injection and was not dependent on the chemical make-up of the contrast agent. Peak medullary enhancement occurred within 3 minutes of bolus injection. Peak medulla CT number following sodium diatrizoate was significantly less than that following metrizamide (P less than 0.025) or iopamidol (P less than 0.01). Peak medulla CT number was significantly less following sodium diatrizoate (P less than 0.01), metrizamide (P less than 0.01) and iopamidol (P less than 0.05) than following sodium ioxaglate. Urine iodine concentrations followed a similar pattern, with significant differences as follows: sodium diatrizoate less than metrizamide = iopamidol less than sodium ioxaglate. It was concluded that the investigational agents metrizamide, iopamidol, and sodium ioxaglate have theoretical advantage for excretory urography. Differences in renal handling of these agents are detectable, with CT scanning as differences in renal medullary enhancement and urine iodine concentration.

  1. Electrolytic pretreatment of urine

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  2. 77 FR 42497 - Information Collection(s) Being Submitted for Review and Approval to the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-19

    ... officer (a post staffed 24 hours a day) in the FCC's Communications and Crisis Management Center in... From the Federal Register Online via the Government Publishing Office FEDERAL COMMUNICATIONS COMMISSION Information Collection(s) Being Submitted for Review and Approval to the Office of Management...

  3. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    2016-01-01

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs. PMID:27645818

  4. Adulterants in Urine Drug Testing.

    PubMed

    Fu, S

    2016-01-01

    Urine drug testing plays an important role in monitoring licit and illicit drug use for both medico-legal and clinical purposes. One of the major challenges of urine drug testing is adulteration, a practice involving manipulation of a urine specimen with chemical adulterants to produce a false negative test result. This problem is compounded by the number of easily obtained chemicals that can effectively adulterate a urine specimen. Common adulterants include some household chemicals such as hypochlorite bleach, laundry detergent, table salt, and toilet bowl cleaner and many commercial products such as UrinAid (glutaraldehyde), Stealth® (containing peroxidase and peroxide), Urine Luck (pyridinium chlorochromate, PCC), and Klear® (potassium nitrite) available through the Internet. These adulterants can invalidate a screening test result, a confirmatory test result, or both. To counteract urine adulteration, drug testing laboratories have developed a number of analytical methods to detect adulterants in a urine specimen. While these methods are useful in detecting urine adulteration when such activities are suspected, they do not reveal what types of drugs are being concealed. This is particularly the case when oxidizing urine adulterants are involved as these oxidants are capable of destroying drugs and their metabolites in urine, rendering the drug analytes undetectable by any testing technology. One promising approach to address this current limitation has been the use of unique oxidation products formed from reaction of drug analytes with oxidizing adulterants as markers for monitoring drug misuse and urine adulteration. This novel approach will ultimately improve the effectiveness of the current urine drug testing programs.

  5. Urine Pretreatment Configuration and Test Results for Space Applications

    NASA Technical Reports Server (NTRS)

    Howard, Stanley G.; Hutchens, Cindy F.; Rethke, Donald W.; Swartley, Vernon L.; Marsh, Robert W.

    1998-01-01

    Pretreatment of urine using Oxone and sulfuric acid is baselined in the International Space Station (ISS) waste water reclamation system to control odors, fix urea and control microbial growth. In addition, pretreatment is recommended for long term flight use of urine collection and two phase separation to reduce or eliminate fouling of the associated hardware and plumbing with urine precipitates. This is important for ISS application because the amount of maintenance time for cleaning and repairing hardware must be minimized. This paper describes the development of a chemical pretreatment system based on solid tablet shapes which are positioned in the urine collection hose and are dissolved by the intrained urine at the proper ratio of pretreatment to urine. Building upon the prior success of the developed and tested solid Oxone tablet a trade study was completed to confirm if a similar approach, or alternative, would be appropriate for the sulfuric acid injection method. In addition, a recommended handling and packaging approach of the solid tablets for long term, safe and convenient use on ISS was addressed. Consequently, the solid tablet concept with suitable packaging was identified as the Urine Pretreat / Prefilter Assembly (UPPA). Testing of the UPPA configuration confirmed the disolution rates and ratios required by ISS were achieved. This testing included laboratory controlled methods as well as a 'real world' test evaluation that occurred during the 150 day Stage 10 Water Recovery Test (WRT) conducted at NASA Marshall Space Flight Center (MSFC).

  6. Advances in Urine Microscopy.

    PubMed

    Becker, Gavin J; Garigali, Giuseppe; Fogazzi, Giovanni B

    2016-06-01

    Urine microscopy is an important tool for the diagnosis and management of several conditions affecting the kidneys and urinary tract. In this review, we describe the automated instruments, based either on flow cytometry or digitized microscopy, that are currently in use in large clinical laboratories. These tools allow the examination of large numbers of samples in short periods. We also discuss manual urinary microscopy commonly performed by nephrologists, which we encourage. After discussing the advantages of phase contrast microscopy over bright field microscopy, we describe the advancements of urine microscopy in various clinical conditions. These include persistent isolated microscopic hematuria (which can be classified as glomerular or nonglomerular on the basis of urinary erythrocyte morphology), drug- and toxin-related cystalluria (which can be a clue for the diagnosis of acute kidney injury associated with intrarenal crystal precipitation), and some inherited conditions (eg, adenine phosphoribosyltransferase deficiency, which is associated with 2,8-dihydroxyadenine crystalluria, and Fabry disease, which is characterized by unique urinary lamellated fatty particles). Finally, we describe the utility of identifying "decoy cells" and atypical malignant cells, which can be easily done with phase contrast microscopy in unfixed samples. PMID:26806004

  7. Urine Culture in Uncomplicated UTI: Interpretation and Significance.

    PubMed

    Stapleton, Ann E

    2016-05-01

    Acute uncomplicated urinary tract infection (UTI) is a common clinical problem, accounting for millions of outpatient visits in the USA annually. Although routinely obtaining urine cultures in UTI is not recommended, there are circumstances in which obtaining a pre-therapy culture may be warranted or chosen by clinicians, such as when indicated by the need for careful antimicrobial stewardship. This review focuses on understanding reasons for obtaining a pre-therapy culture, methods of collection, and appropriately interpreting urine culture data.

  8. Pregnancy diagnosis in urine of Iberian lynx (Lynx pardinus).

    PubMed

    Braun, B C; Frank, A; Dehnhard, M; Voigt, C C; Vargas, A; Göritz, F; Jewgenow, K

    2009-03-15

    Diagnosis of pregnancies is an important management tool for the Iberian lynx Conservation Breeding Program, a program geared to recover the world's most endangered felid. Non-invasive methods such as fecal hormone analyses are not applicable to the lynx, since fecal progestin does not follow the typical pregnancy pattern of felids. Therefore, we aimed to test whether urine can be used as an alternative substance for pregnancy diagnosis in the Iberian lynx. Progesterone immunoreactive metabolites were determined in urine samples of pregnant and non-pregnant females before and during breeding season. Additionally, we used the Witness Relaxin test to determine relaxin in blood and urine. No differences were found in progestin concentrations determined in urine samples collected from pregnant and non-pregnant animals between day 1 and 65 following mating. Although the Witness Relaxin test was positive in serum samples collected from animals between day 32 and 56 of pregnancy, it failed in both fresh and frozen urine samples collected from the same stage of pregnancy. A weak relaxin reaction in urine samples collected from animals between day 29 and 46 of pregnancy was detectable after urines were concentrated by ultrafiltration (>50x). Concentrated samples obtained from non-pregnant and early pregnant animals yielded negative test results. In conclusion, the Witness Relaxin test can be applied for pregnancy diagnosis in Iberian lynx in both serum and concentrated urine samples obtained during the second half of pregnancy. A positive relaxin test indicates an ongoing pregnancy, whereas negative tests must be judged carefully as hormone concentrations might be below detection thresholds.

  9. A study of metabolites isolated from the urine samples of cats and dogs administered orbifloxacin.

    PubMed

    Matsumoto, S; Takahashi, M; Kitadai, N; Katae, H

    1998-11-01

    Urine samples of cats and dogs collected for 24 hr after a subcutaneous injection of orbifloxacin (OBFX) were analyzed. The metabolites were examined using HPLC. In the dog urine, 87% of total was the parent compound and 13% glucuronide compound of OBFX and 96% was parent and 4% metabolite in the cat urine. The metabolite of cat urine was identified as N-hydroxy OBFX, determined by comparison of the extraction of urine with chloroform with the standard compound of N-hydroxy OBFX, using LC/APCIMS. N-hydroxy OBFX had a weaker antibacterial activity against fluoroquinolone sensitive bacteria than the parent compound.

  10. The effects of urine concentration, and cushion centrifugation to remove urine, on the quality of cool-stored stallion sperm.

    PubMed

    Voge, Jared; Varner, Dickson D; Blanchard, Terry L; Meschini, Marika; Turner, Carly; Teague, Sheila R; Brinsko, Steven P; Love, Charles C

    2016-09-15

    Urine-contaminated stallion semen is a clinical problem due to a variety of causes. The effect of the level of urine contamination on the longevity of sperm quality has not been evaluated. The aim of this study was to determine the effects of urine concentration level (0%, 10%, 20%, 30%, and 40%) and cushioned centrifugation and resuspension of the sperm pellet in fresh extender, on measures of sperm quality, immediately after semen collection (T0), after 1 hour of storage at room temperature (T1), and after 24 hours of cooled storage (T24). In general, most sperm quality measures declined with increasing urine concentration starting at T0. Cushioned centrifugation (CC), but not simple dilution, generally maintained sperm quality at T24 as compared with T1. At T24, total sperm motility was higher in all urine-contaminated CC samples compared with uncentrifuged samples (P < 0.05); sperm viability was lower in CC than uncentrifuged at a urine concentration of 20%, but higher at 30% and 40% (P < 0.05); and DNA quality was decreased (higher % cells outside the main population) in all urine concentrations (P < 0.05). Immediate extension in semen extender, followed by cushioned centrifugation and resuspension of the sperm pellet in fresh extender, provided the best option for preserving sperm quality of urospermic semen. PMID:27349135

  11. Permeation profiles of potential urine-borne biomarkers of human presence over brick and concrete.

    PubMed

    Mochalski, Paweł; Agapiou, Agapios; Statheropoulos, Milt; Amann, Anton

    2012-07-21

    Headspace solid phase micro-extraction gas chromatography-mass spectrometry (SPME-GC-MS) analysis was performed over an in-house made filling chamber loaded with brick or concrete, mimicking a potential entrapment scene of building collapse following natural or man-made disasters. Permeation profiles of 22 volatile species, released by human urine samples, were quantitatively monitored over the selected debris materials for a time period of 24 hours (LODs ranged from 0.05-0.8 ppb, R(2) varied from 0.991-0.999 and RSDs 3-9%). Ketones were the most abundant constituents of urine vapor with eleven representatives followed by five aldehydes, two furans, two sulphur-containing compounds, one nitrile and one heterocyclic compound. The majority of the detected compounds were found below 10 ppb, with the exception of some ketones including acetone, 2-butanone and 2-pentanone. The influence of debris materials on the permeation profiles of analytes under study depended on their fundamental physicochemical properties. Less volatile and more soluble compounds in urine (ketones and aldehydes) were found to be present for longer time periods in the surroundings of the urine samples than the more volatile and poorly soluble ones (furans, sulphur-containing compounds). More specifically, ketones exhibited longer residence times in the filling chamber and strongly interacted with the debris materials as their molecular masses were increased; their profiles were found to be significantly modified in the presence of concrete. In general, concrete demonstrated a stronger interaction with urine species than brick, affecting the observed concentrations and residence times of released volatiles in the chamber. PMID:22662321

  12. Permeation profiles of potential urine-borne biomarkers of human presence over brick and concrete.

    PubMed

    Mochalski, Paweł; Agapiou, Agapios; Statheropoulos, Milt; Amann, Anton

    2012-07-21

    Headspace solid phase micro-extraction gas chromatography-mass spectrometry (SPME-GC-MS) analysis was performed over an in-house made filling chamber loaded with brick or concrete, mimicking a potential entrapment scene of building collapse following natural or man-made disasters. Permeation profiles of 22 volatile species, released by human urine samples, were quantitatively monitored over the selected debris materials for a time period of 24 hours (LODs ranged from 0.05-0.8 ppb, R(2) varied from 0.991-0.999 and RSDs 3-9%). Ketones were the most abundant constituents of urine vapor with eleven representatives followed by five aldehydes, two furans, two sulphur-containing compounds, one nitrile and one heterocyclic compound. The majority of the detected compounds were found below 10 ppb, with the exception of some ketones including acetone, 2-butanone and 2-pentanone. The influence of debris materials on the permeation profiles of analytes under study depended on their fundamental physicochemical properties. Less volatile and more soluble compounds in urine (ketones and aldehydes) were found to be present for longer time periods in the surroundings of the urine samples than the more volatile and poorly soluble ones (furans, sulphur-containing compounds). More specifically, ketones exhibited longer residence times in the filling chamber and strongly interacted with the debris materials as their molecular masses were increased; their profiles were found to be significantly modified in the presence of concrete. In general, concrete demonstrated a stronger interaction with urine species than brick, affecting the observed concentrations and residence times of released volatiles in the chamber.

  13. Toenail, Blood and Urine as Biomarkers of Manganese Exposure

    PubMed Central

    Laohaudomchok, Wisanti; Lin, Xihong; Herrick, Robert F.; Fang, Shona C.; Cavallari, Jennifer M.; Christiani, David C.; Weisskopf, Marc G.

    2011-01-01

    Objective This study examined the correlation between manganese exposure and manganese concentrations in different biomarkers. Methods Air measurement data and work histories were used to determine manganese exposure over a workshift and cumulative exposure. Toenail samples (n=49), as well as blood and urine before (n=27) and after (urine, n=26; blood, n=24) a workshift were collected. Results Toenail manganese, adjusted for age and dietary manganese, was significantly correlated with cumulative exposure in months 7-9, 10-12, and 7-12 before toenail clipping date, but not months 1-6. Manganese exposure over a work shift was not correlated with changes in blood nor urine manganese. Conclusions Toenails appeared to be a valid measure of cumulative manganese exposure 7 to 12 months earlier. Neither change in blood nor urine manganese appeared to be suitable indicators of exposure over a typical workshift. PMID:21494156

  14. [Pastel in the urine bag].

    PubMed

    Cantaloube, Lucie; Lebaudy, Cécile; Hermabessière, Sophie; Rolland, Yves

    2012-03-01

    Purple urine bag syndrome is a relatively unknown phenomenon in which the urine bag and the collector of chronically catheterized patients turn purple or blue. It affects predominantly women, and is mainly reported in elderly patients. The mechanism seems to be related to the appearance in the urine of two compounds that have been identified as indigo (blue) and indirubin (red) which bind to the urine bag and the collector. Several associated factors are usually mentioned such as constipation, alkaline urine, bed rest, institutionalization or cognitive impairment. They are risk factor of this phenomenon. On the other hand, an infection or a urinary bacterial colonization is necessary and high bacterial counts seem to be the critical step in the development of the purple urine bag syndrome. We report on two cases of purple urine bag syndrome observed in two patients being treated in a long-term care unit. Both of whom were diagnosed with indwelling urinary bacterial colonization, with Escherichia coli and Pseudomonas aeruginosa respectively.

  15. Chemical differences between voided and bladder urine in the aye-aye (Daubentonia madagascariensis): implications for olfactory communication studies.

    PubMed

    Delbarco-Trillo, Javier; Harelimana, Innocent H; Goodwin, Thomas E; Drea, Christine M

    2013-07-01

    Urine serves a communicative function in many mammalian species. In some species, the signaling function of urine can be enhanced by the addition of chemical compounds from glands along the distal portion of the urogenital tract. Although urine marking is the main mode of chemical communication in many primate species, there has been no study of the contribution of urogenital secretions to the chemical complexity of primate urine. Here, we compared the chemical composition of bladder urine versus voided urine in the aye-aye, Daubentonia madagascariensis, a strepsirrhine primate that relies on urine in intraspecific communication. Both types of urine, collected from each of 11 aye-ayes representing both sexes of varying adult ages, underwent headspace analysis via gas chromatography and mass spectrometry. Although the average number of compounds was similar in bladder and voided urine, 17% of the compounds detected occurred exclusively in voided urine (but only in a subset of individuals). An overall measure of chemical complexity (using a nonmetric multidimensional scaling analysis) showed that both types of urine were chemically different at the individual level. There was no apparent sex or age differences in the chemical components found in aye-aye urine. Nonetheless, the individual dissimilarities between bladder urine and voided urine indicate chemical contributions from structures along the urogenital tract and offer further support for the relevance of urinary communication in the aye-aye.

  16. An Observational Study of Blood Glucose Levels during Admission and 24 Hours Post-Operation in a Sample of Patients with Traumatic Injury in a Hospital in Kuala Lumpur

    PubMed Central

    Harun @ Haron, Rahmat; Imran, Musa Kamarul; Haspani, Mohammed Saffari Mohammed

    2011-01-01

    Background: Traumatic brain injury (TBI) has been associated with an acute stress response mediated by the sympathoadrenomedullary axis, which can be assessed by measuring blood glucose level. Methods: This prospective observational study was conducted for a year in 2007 among 294 patients who had been treated for TBI in Hospital Kuala Lumpur. Patients fulfilling the set criteria were recruited into the study and data, including blood glucose level and Glasgow Outcome Score at 3-month follow-up, were collected. Results: 294 patients were included in the study: 50 females (17.0%) and 244 males (83.0%). The majority of cases were young adult patients (mean age of 34.2 years, SD 13.0). The mean blood glucose level during admission and post-surgery were 6.26 mmol/L (SD 1.30, n = 294) and 6.66 mmol/L (SD 1.44, n = 261), respectively. Specifically, the mean admission glucose level associated with mild TBI was 5.04 mmol/L (SD 0.71); moderate TBI, 5.78 mmol/L (SD 1.02); and severe TBI, 7.04 mmol/L (SD 1.18). The mean admission glucose level associated with a poor outcome in patients with isolated TBI was 6.98 mmol/L (SD 1.21). Patients with admission glucose of 5.56 mmol/L (SD 1.21) were more likely to have a favourable outcome. Conclusion: Mild, moderate, and severe TBI were associated with an increase in blood glucose levels during admission, and the mean increase in glucose levels is based on the severity of the isolated TBI. Surgical intervention did not cause further significant changes in blood glucose levels. Patients with isolated TBI and minimal increases in blood glucose levels were more likely to have a favourable outcome. PMID:22589675

  17. Treating urine by Spirulina platensis

    NASA Astrophysics Data System (ADS)

    Yang, Chenliang; Liu, Hong; Li, Ming; Yu, Chengying; Yu, Gurevich

    In this paper Spirulina platensis with relatively high nutrition was cultivated to treat human urine. Batch culture showed that the consumption of N in human urine could reach to 99%, and the consumption of P was more than 99.9%, and 1.05 g biomass was obtained by treating 12.5 ml synthetic human urine; continuous culture showed that S. platensis could consume N, Cl, K and S in human urine effectively, and the consumption could reach to 99.9%, 75.0%, 83.7% and 96.0%, respectively, and the consumption of P was over 99.9%, which is very important to increase the closure and safety of the bioregenerative life support system (BLSS).

  18. EDRN Pre-Validation of Multiplex Biomarker in Urine — EDRN Public Portal

    Cancer.gov

    The goal of this proposal is to begin to establish an EDRN “pre-validation” trial of a multiplex set of transcripts, including the ETS gene fusions, in post-DRE urine sediments. As can be evidenced by our preliminary data, we have established the utility of this multiplex urine test (which includes TMPRSS-ERG, SPINK1, PCA3 and GOLPH2) in a cohort of prospectively collected urine sediments from the University of Michigan EDRN CEVC site (collected by co-I, Dr. John Wei). In this proposal, we will run this multiplex assay on prospectively collected post-DRE urines collected from other EDRN sites. The idea is to couple this “pre-validation” study with an EDRN validation trial under consideration for the Gen-Probe PCA3 urine test (directed by Drs. John Wei and Harry Rittenhouse).

  19. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of benzyl butyl phthalate and its metabolites, monobenzyl phthalate and monobutyl phthalate, in rat plasma, urine, and various tissues collected from a toxicokinetic study.

    PubMed

    Kim, Min Gi; Kim, Tae Hwan; Shin, Beom Soo; Lee, Yong-Bok; Lee, Jong Bong; Choi, Hyeon Gwan; Lee, Youngsung; Yoo, Sun Dong

    2015-09-01

    This study describes the development of a sensitive liquid chromatography-electrospray-tandem mass spectrometry method for the simultaneous determination of benzyl butyl phthalate (BBP) and its major metabolites, monobenzyl phthalate (MBzP) and monobutyl phthalate (MBuP), in rat plasma, urine, and 10 different tissues. The method was validated with regard to the specificity, linearity, precision, accuracy, lower limit of quantification (LLOQ), recovery, and stability by using the matrix-matched quality control samples. The assay achieved LLOQ of 1 ng/ml of BBP for plasma and urine, 4 ng/g for kidney and liver, 10 ng/g for fat, and 20 ng/g for all other tissues. For MBzP and MBuP, the assay achieved LLOQ of 5 ng/ml for plasma and urine, 10 ng/g for fat, and 20 ng/g for all other tissues. The disposition of BBP was characterized by a large volume of distribution (71.1-82.9 l/kg) and a high clearance (838.7-871.0 ml/min/kg). It was extensively metabolized to MBzP and MBuP, with their levels consistently exceeding the BBP levels. The distribution of BBP, MBzP, and MBuP to tissues of kidney, liver, stomach, small intestine, large intestine, spleen, brain, testis, thyroid, and fat was determined under steady-state conditions. For BBP, the steady-state tissue-to-plasma partition coefficient (K p) was the highest for fat (25.0) followed by small intestine (2.6), thyroid (2.0), and stomach (1.1). In contrast, for MBzP and MBuP, it was the highest for kidney (2.0 and 4.3, respectively) and liver (4.3 and 2.1, respectively) but was less than unity for all other tissues. The developed assay method and findings of this study may be useful to evaluate the exposure and toxic potential of BBP and its metabolites in risk assessment. PMID:26168976

  20. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  1. Uncertainties of Mayak urine data

    SciTech Connect

    Miller, Guthrie; Vostrotin, Vadim; Vvdensky, Vladimir

    2008-01-01

    For internal dose calculations for the Mayak worker epidemiological study, quantitative estimates of uncertainty of the urine measurements are necessary. Some of the data consist of measurements of 24h urine excretion on successive days (e.g. 3 or 4 days). In a recent publication, dose calculations were done where the uncertainty of the urine measurements was estimated starting from the statistical standard deviation of these replicate mesurements. This approach is straightforward and accurate when the number of replicate measurements is large, however, a Monte Carlo study showed it to be problematic for the actual number of replicate measurements (median from 3 to 4). Also, it is sometimes important to characterize the uncertainty of a single urine measurement. Therefore this alternate method has been developed. A method of parameterizing the uncertainty of Mayak urine bioassay measmements is described. The Poisson lognormal model is assumed and data from 63 cases (1099 urine measurements in all) are used to empirically determine the lognormal normalization uncertainty, given the measurement uncertainties obtained from count quantities. The natural logarithm of the geometric standard deviation of the normalization uncertainty is found to be in the range 0.31 to 0.35 including a measurement component estimated to be 0.2.

  2. Ethylglucuronide determination in urine and hair from alcohol withdrawal patients.

    PubMed

    Concheiro, Marta; Cruz, Angelines; Mon, Marisol; de Castro, Ana; Quintela, Oscar; Lorenzo, Angeles; López-Rivadulla, Manuel

    2009-04-01

    Two methods for the determination of ethylglucuronide (EtG) in urine and in hair have been developed by liquid chromatography- tandem mass spectrometry. These two methods were fully validated, including linearity (0.25-100 microg/mL in urine; 0.05-5 ng/mg in hair; r(2) > 0.99, n = 5), limits of detection (0.1 microg/mL in urine, 0.025 ng/mg in hair) and quantitation (lowest level of the calibration curve), extraction efficiency (> 55%), within-day and between-day imprecision and bias (CV and mean relative error < 15%), matrix effect, and relative ion intensity. These methods have been applied to 541 urine samples and 17 hair specimens collected from 156 alcohol withdrawal patients. The determination of ethanol versus EtG in urine was compared, and also the convenience of EtG determination in hair. EtG in urine and in hair proved to be a powerful tool for monitoring abstinence in these patients. PMID:19371464

  3. Rethinking the Youth Weight Debate: The 24 Hour Day

    ERIC Educational Resources Information Center

    Dodd, Graham; Biggs, Sarah; Agley, Daniel; Dollman, James; Lushington, Kurt

    2008-01-01

    Approaches to weight management have traditionally focussed on caloric intake versus caloric expenditure. Despite a range of interventions based on these approaches, the proportion of overweight children and adolescents continues to rise. There are increasing indications that other factors, such as sleep duration, may be at play. This commentary…

  4. Sun Blasts 6 CMEs in 24 Hour Period

    NASA Video Gallery

    This movie from the chronograph on board the SOlar and Heliospheric Observatory (SOHO), shows the sun's atmosphere – the corona – from September 17 to September 20. The sun let loose with at ...

  5. Boerhaave's syndrome: Experience with patients presenting later than 24 hours.

    PubMed

    Ganguly, Amit; Porwal, Manish; Khandeparkar, Jagdish

    2015-01-01

    Boerhaave's syndrome is the most sinister cause of esophageal perforation. Clinical presentation is vague. Diagnostic delays are frequent. As condition is rare therefore no consensus exists on management. A wide variety of management options are described in literature, each with its advantages and disadvantages. We present our experience of managing these cases which presented after 24 hr. Of onset of symptoms with emphasis on primary reinforced repair as first line surgical option. PMID:27522739

  6. Attenuated sympathetic nerve responses after 24 hours of bed rest

    NASA Technical Reports Server (NTRS)

    Khan, Mazhar H.; Kunselman, Allen R.; Leuenberger, Urs A.; Davidson, William R Jr; Ray, Chester A.; Gray, Kristen S.; Hogeman, Cynthia S.; Sinoway, Lawrence I.

    2002-01-01

    Bed rest reduces orthostatic tolerance. Despite decades of study, the cause of this phenomenon remains unclear. In this report we examined hemodynamic and sympathetic nerve responses to graded lower body negative pressure (LBNP) before and after 24 h of bed rest. LBNP allows for baroreceptor disengagement in a graded fashion. We measured heart rate (HR), cardiac output (HR x stroke volume obtained by echo Doppler), and muscle sympathetic nerve activity (MSNA) during a progressive and graded LBNP paradigm. Negative pressure was increased by 10 mmHg every 3 min until presyncope or completion of -60 mmHg. After bed rest, LBNP tolerance was reduced in 11 of 13 subjects (P <.023), HR was greater (P <.002), cardiac output was unchanged, and the ability to augment MSNA at high levels of LBNP was reduced (rate of rise for 30- to 60-mmHg LBNP before bed rest 0.073 bursts x min(-1) x mmHg(-1); after bed rest 0.035 bursts x min(-1) x mmHg(-1); P < 0.016). These findings suggest that 24 h of bed rest reduces sympathetic nerve responses to LBNP.

  7. A 24-hour remote surveillance system for terrestrial wildlife studies

    USGS Publications Warehouse

    Sykes, P.W.; Ryman, W.E.; Kepler, C.B.; Hardy, J.W.

    1995-01-01

    The configuration, components, specifications and costs of a state-of-the-art closed-circuit television system with wide application for wildlife research and management are described. The principal system components consist of color CCTV camera with zoom lens, pan/tilt system, infrared illuminator, heavy duty tripod, coaxial cable, coaxitron system, half-duplex equalizing video/control amplifier, timelapse video cassette recorder, color video monitor, VHS video cassettes, portable generator, fuel tank and power cable. This system was developed and used in a study of Mississippi sandhiIl Crane (Grus canadensis pratensis) behaviors during incubation, hatching and fledging. The main advantages of the system are minimal downtime where a complete record of every event, its time of occurrence and duration, are permanently recorded and can be replayed as many times as necessary thereafter to retrieve the data. The system is particularly applicable for studies of behavior and predation, for counting individuals, or recording difficult to observe activities. The system can be run continuously for several weeks by two people, reducing personnel costs. This paper is intended to provide biologists who have litte knowledge of electronics with a system that might be useful to their specific needs. The disadvantages of this system are the initial costs (about $9800 basic, 1990-1991 U.S. dollars) and the time required to playback video cassette tapes for data retrieval, but the playback can be sped up when litte or no activity of interest is taking place. In our study, the positive aspects of the system far outweighed the negative.

  8. Decreased 24-hour urinary MHPG in childhood autism.

    PubMed

    Young, J G; Cohen, D J; Caparulo, B K; Brown, S L; Maas, J W

    1979-08-01

    The authors compared a group of boys with childhood autism and a group of normal boys of similar age and found a decrease in urinary 3-methoxy-4-hydroxyphenethylene glycol (MHPG) in the autistic group. They hypothesize that autistic children might have an alteration in central and peripheral noradrenergic function, which might be related to impaired regulation of attention, arousal, and anxiety.

  9. Creating a urine black hole

    NASA Astrophysics Data System (ADS)

    Hurd, Randy; Pan, Zhao; Meritt, Andrew; Belden, Jesse; Truscott, Tadd

    2015-11-01

    Since the mid-nineteenth century, both enlisted and fashion-conscious owners of khaki trousers have been plagued by undesired speckle patterns resulting from splash-back while urinating. In recent years, industrial designers and hygiene-driven entrepreneurs have sought to limit this splashing by creating urinal inserts, with the effectiveness of their inventions varying drastically. From this large assortment of inserts, designs consisting of macroscopic pillar arrays seem to be the most effective splash suppressers. Interestingly this design partially mimics the geometry of the water capturing moss Syntrichia caninervis, which exhibits a notable ability to suppress splash and quickly absorb water from impacting rain droplets. With this natural splash suppressor in mind, we search for the ideal urine black hole by performing experiments of simulated urine streams (water droplet streams) impacting macroscopic pillar arrays with varying parameters including pillar height and spacing, draining and material properties. We propose improved urinal insert designs based on our experimental data in hopes of reducing potential embarrassment inherent in wearing khakis.

  10. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2015-01-01

    An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS). The bioavailability and pharmacokinetics (PK) were evaluated under IND (Investigational New Drug) guidelines. The aim of the project was to develop a PK model that can predict the relationships among plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial protocol with INSCOP. Twelve healthy human subjects were administered at three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. PK compartmental models, using actual dosing and sampling time, were established using Phoenix (version 1.2). Model selection was based on a likelihood ratio test on the difference of criteria (-2LL (i.e. log-likelihood ratio test)) and comparison of the quality of fit plots. The results: Predictable correlations among scopolamine concentrations in compartments of plasma, saliva and urine were established, and for the first time the model satisfactorily predicted the population and individual PK of INSCOP in plasma, saliva and urine. The model can be utilized to predict the INSCOP plasma concentration by saliva and urine data, and it will be useful for monitoring the PK of scopolamine in space and other remote environments using non-invasive sampling of saliva and/or urine.

  11. Is alpha spectrometry reliable for ²¹⁰Po urine bioassay?

    PubMed

    Li, Chunsheng; Sadi, Baki; Davis, Karelyn; Wyatt, Heather; Cornett, Jack; Kramer, Gary

    2011-01-01

    Typically the bioassay method for (210)Po in urine by alpha spectrometry (AS) involves wet decomposition of the sample, which may cause a loss of (210)Po if volatile species are present. To test this hypothesis, urine samples collected from two rats that were i.v. administered with polonium citrate were measured by both AS and liquid scintillation counting, where urine samples were mixed with a scintillation cocktail without any treatment. A split-plot design method was used to compare results from the two measurement methods, showing no evidence of a difference between the two methods. This suggests that the AS method is reliable for (210)Po urine bioassay.

  12. Ebola Virus RNA Stability in Human Blood and Urine in West Africa's Environmental Conditions.

    PubMed

    Janvier, Frédéric; Delaune, Deborah; Poyot, Thomas; Valade, Eric; Mérens, Audrey; Rollin, Pierre E; Foissaud, Vincent

    2016-02-01

    We evaluated RNA stability of Ebola virus in EDTA blood and urine samples collected from infected patients and stored in West Africa's environmental conditions. In blood, RNA was stable for at least 18 days when initial cycle threshold values were <30, but in urine, RNA degradation occurred more quickly.

  13. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the...

  14. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the...

  15. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the...

  16. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the...

  17. 10 CFR 26.111 - Checking the acceptability of the urine specimen.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Checking the acceptability of the urine specimen. 26.111 Section 26.111 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.111 Checking the acceptability of the urine specimen. (a) Immediately after the...

  18. Interaction of hydrophobic components in female urine before and after childbirth with P-glycoprotein in vitro.

    PubMed

    Yokooji, T; Kameda, Y; Utsumi, M; Mori, N; Murakami, T

    2014-06-01

    The first urine in the morning (total 15 samples) and whole day urine (total 4 days, 17 samples) were collected from a young healthy woman during the pregnancy and lactation period, to examine the possible interactions of urine components (methanol extracts) with P-glycoprotein (P-gp) and multidrug resistance-associated proteins (MRPs). The interaction was evaluated by measuring the intracellular accumulation of rhodamine123, a P-gp substrate, in LLC-GA5-COL150 cells, or calcein, an MRP substrate, in Caco-2 cells in the absence and presence of urine components. Four first urine samples out of 12 collected before childbirth and one sample out of three collected after childbirth suppressed P-gp function significantly. The effect of pregnancy and lactation on P-gp inhibitory potencies of urine components was not observed. The whole day urine samples showed a clear circadian rhythm, in which three first urine samples in the morning out of four showed greater P-gp inhibitory potencies than other daytime samples. Interaction of urine components with MRPs was not detected. In conclusion, the concentration of endogenous P-gp inhibitor(s) was higher in the first urine in the morning, showing a clear circadian rhythm. Normal pregnancy and lactation appeared not to significantly affect the P-gp inhibitory potencies of urine components.

  19. The impact of fertilization on the chicken egg yolk plasma and granule proteome 24 hours post-lay at room temperature: capitalizing on high-pH/low-pH reverse phase chromatography in conjunction with tandem mass tag (TMT) technology.

    PubMed

    Padliya, Neerav D; Qian, Meiqian; Mimi Roy, Sushmita; Chu, Patrick; Zheng, Haiyan; Tess, Alex; Dariani, Maghsoud; Hariri, Robert J

    2015-07-01

    Chicken egg yolk is a rich source of nutrients providing high quality proteins, vitamins, minerals, carotenoids and antioxidants. Chicken egg yolk, recovered from whole egg within 24 hours post-lay has been utilized as a starting material in the preparation of a dietary supplement that has been demonstrated to lead to gains in muscle mass in a human clinical study. Further, an oil derived from chicken egg yolk has been utilized as a topical agent to treat third degree burn injury. The molecular changes that take place in fertilized, chicken egg yolk during the first 24 hours post-lay are not well understood. By studying how the protein composition of egg yolk varies with fertility status, one can utilize this knowledge to develop egg yolk-based products that have been optimized for specific applications. In this study, a direct quantitative comparison was made between the proteome of fertilized chicken egg yolk and the proteome of unfertilized chicken egg yolk, both maintained at 20 °C and analyzed within 24 hours post-lay. Egg yolk proteins from each fertility state were digested with trypsin, labeled with distinct chemical labels (tandem mass tag reagents) and then combined in a 1 : 1 ratio. A TMT-labeled tryptic digest derived from chicken egg yolk proteins (fertilized and unfertilized) was separated using high-pH/low-pH reverse-phase chromatography and analyzed using mass spectrometry. 225 protein identifications were made from this TMT-labeled tryptic digest based on a minimum of 2 unique peptides observed per protein. 9 proteins increased in abundance in fertilized egg yolk relative to unfertilized egg yolk and 9 proteins decreased in abundance in fertilized egg yolk relative to unfertilized egg yolk. Some proteins that increased in abundance in fertilized egg yolk play an important role in angiogenesis (pleiotrophin, histidine rich glycoprotein) and defense against pathogens (mannose-binding lectin, β-defensin 11, serum amyloid P-component, ovostatin

  20. Value of estimating methylamalonic acid excretion in anaemia.

    PubMed

    Green, A E; Pegrum, G D

    1968-09-01

    A rapid technique suitable for routine pathology laboratories has been used to estimate methylmalonic acid excretion in a 24-hour urine collection following a 10g. valine load. Levels above 40 mg./24 hours were found only in patients with vitamin B(12) deficiency. Patients with pernicious anaemia treated more than 24 hours before urine collection and patients with other types of anaemia had methylmalonic acid levels below 25 mg./24 hours.This method of demonstrating vitamin B(12) deficiency can be applied rapidly in debilitated patients so that specific treatment can be instituted within 36 hours of admission.

  1. Relationship Between the Urine Flow Rate and Risk of Contrast-Induced Nephropathy After Emergent Percutaneous Coronary Intervention

    PubMed Central

    Liu, Yong; Lin, Lixia; Li, Yun; Li, Hualong; Wu, Deng-Xuan; Zhao, Jian-bin; Lian, Dan; Zhou, Yingling; Liu, Yuanhui; Ye, Piao; Ran, Peng; Duan, Chongyang; Chen, Shiqun; Chen, Pingyan; Xian, Ying; Chen, Jiyan; Tan, Ning

    2015-01-01

    Abstract A low urine flow rate is a marker of acute kidney injury. However, it is unclear whether a high urine flow rate is associated with a reduced risk of contrast-induced nephropathy (CIN) in high-risk patients. We conducted this study to evaluate the predictive value of the urine flow rate for the risk of CIN following emergent percutaneous coronary intervention (PCI). We prospectively examined 308 patients undergoing emergent PCI who provided consent. The predictive value of the 24-hour postprocedural urine flow rate, adjusted by weight (UR/W, mL/kg/h) and divided into quartiles, for the risk of CIN was assessed using multivariate logistic regression analysis. The cumulative incidence of CIN was 24.4%. In particular, CIN was observed in 29.5%, 19.5%, 16.7%, and 32.0% of cases in the UR/W quartile (Q)-1 (≤0.94 mL/kg/h), Q2 (0.94–1.30 mL/kg/h), Q3 (1.30–1.71 mL/kg/h), and Q4 (≥1.71 mL/kg/h), respectively. Moreover, in-hospital death was noted in 7.7%, 3.9%, 5.1%, and 5.3% of patients in Q1, Q2, Q3, and Q4, respectively. After adjusting for potential confounding predictors, multivariate analysis indicated that compared with the moderate urine flow rate quartiles (Q2 + Q3), a high urine flow rate (Q4) (odds ratio [OR], 2.69; 95% confidence interval [CI], 1.27–5.68; P = 0.010) and low urine flow rate (Q1) (OR, 2.23; 95% CI, 1.03–4.82; P = 0.041) were significantly associated with an increased risk of CIN. Moreover, a moderate urine flow rate (0.94–1.71 mL/kg/h) was significantly associated with a decreased risk of mortality. Our data suggest that higher and lower urine flow rates were significantly associated with an increased risk of CIN after emergent PCI, and a moderate urine flow rate (0.94–1.71 mL/kg/h) may be associated with a decreased risk of CIN with a good long-term prognosis after emergent PCI. PMID:26683946

  2. 49 CFR 40.47 - May employers use the CCF for non-Federal collections or non-Federal forms for DOT collections?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Collection Sites, Forms, Equipment and Supplies Used in DOT Urine Collections § 40.47 May employers use the... are prohibited from using the CCF for non-Federal urine collections. You are also prohibited from using non-Federal forms for DOT urine collections. Doing either subjects you to enforcement action...

  3. 49 CFR 40.47 - May employers use the CCF for non-Federal collections or non-Federal forms for DOT collections?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Collection Sites, Forms, Equipment and Supplies Used in DOT Urine Collections § 40.47 May employers use the... are prohibited from using the CCF for non-Federal urine collections. You are also prohibited from using non-Federal forms for DOT urine collections. Doing either subjects you to enforcement action...

  4. Hair: A Diagnostic Tool to Complement Blood Serum and Urine.

    ERIC Educational Resources Information Center

    Maugh, Thomas H., II

    1978-01-01

    Trace elements and some drugs can be identified in hair and it seems likely that other organic chemicals will be identifiable in the future. Since hair is so easily collected, stored, and analyzed it promises to be an ideal complement to serum and urine analysis as a diagnostic tool. (BB)

  5. Human intoxication with paralytic shellfish toxins: clinical parameters and toxin analysis in plasma and urine.

    PubMed

    García, Carlos; Lagos, Marcelo; Truan, Dominique; Lattes, Karinna; Véjar, Omar; Chamorro, Beatriz; Iglesias, Verónica; Andrinolo, Darío; Lagos, Néstor

    2005-01-01

    This study reports the data recorded from four patients intoxicated with shellfish during the summer 2002, after consuming ribbed mussels (Aulacomya ater) with paralytic shellfish toxin contents of 8,066 +/- 61.37 microg/100 gr of tissue. Data associated with clinical variables and paralytic shellfish toxins analysis in plasma and urine of the intoxicated patients are shown. For this purpose, the evolution of respiratory frequency, arterial blood pressure and heart rate of the poisoned patients were followed and recorded. The clinical treatment to reach a clinically stable condition and return to normal physiological parameters was a combination of hydration with saline solution supplemented with Dobutamine (vasoactive drug), Furosemide (diuretic) and Ranitidine (inhibitor of acid secretion). The physiological condition of patients began to improve after four hours of clinical treatment, and a stable condition was reached between 12 to 24 hours. The HPLC-FLD analysis showed only the GTX3/GTX2 epimers in the blood and urine samples. Also, these epimers were the only paralytic shellfish toxins found in the shellfish extract sample. PMID:16238098

  6. The International Space Station Urine Monitoring System (UMS)

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.

    2009-01-01

    A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification

  7. Urine Culture in Uncomplicated UTI: Interpretation and Significance.

    PubMed

    Stapleton, Ann E

    2016-05-01

    Acute uncomplicated urinary tract infection (UTI) is a common clinical problem, accounting for millions of outpatient visits in the USA annually. Although routinely obtaining urine cultures in UTI is not recommended, there are circumstances in which obtaining a pre-therapy culture may be warranted or chosen by clinicians, such as when indicated by the need for careful antimicrobial stewardship. This review focuses on understanding reasons for obtaining a pre-therapy culture, methods of collection, and appropriately interpreting urine culture data. PMID:26971335

  8. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  9. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    SciTech Connect

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitable sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.

  10. [Determination of dimethylbenzoic acid isomers in urine by gas chromatography].

    PubMed

    Kostrzewski, P; Wiaderna-Brycht, A; Czerski, B

    1994-01-01

    Trimethylobenzene (TMB) is a main ingredient of many organic solvents used in industry. In Farbasol (Polish trade name of the solvent) TMB occurs as a mixture of three isomers: pseudocumene (1, 2, 4-TMB) 30%; mesitylene (1, 3, 5-TMB) 15%; hemimellitene (1,2,3-TMB) 5%. As it is known in human organism, TMB is metabolized mainly to dimethylbenzoic (DMBA) and dimethylhippuric (DMHA) acids, and some authors suggest, that the acids excreted in urine can be biological indicators of exposure to TMB. This study was aimed at developing the method of determination of DMBA isomers in urine. Biological material was hydrolyzed with sodium hydroxide and next extracted with diethyl ether. DMBA concentration in urine was determined by gas chromatography using a variant of quantitative analysis with internal standard (5-methyl-2-isopropylphenol, thymol). Analytical parameters of the developed method of determination of DMBA isomers in urine such as linearity, precision, reproducibility, stability (192 days, when urine samples stored at-18 degrees C), detectability limit (400 micrograms/dm3) have been fully compatible with the requirements of biological monitoring. In order to confirm the presence of DMBA isomers in urine, four volunteers were exposed (8 hours) to Farbasol in toxicological chamber. The TMB concentration in the air, determined by means of gas chromatograph (HP 5890), amounted to 100 mg/m3 (MAC value in Poland). In urine samples collected 2,3-; 2,4-; 2,5-; 2,6-; 3,4-; 3,5-dimethylbenzoic acids were identified by means of GC/MSD.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8170375

  11. Chemical measurement of urine volume

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.

    1978-01-01

    Chemical method of measuring volume of urine samples using lithium chloride dilution technique, does not interfere with analysis, is faster, and more accurate than standard volumetric of specific gravity/weight techniques. Adaptation of procedure to urinalysis could prove generally practical for hospital mineral balance and catechoamine determinations.

  12. Development of Urine Receptacle Assembly for the Crew Exploration Vehicle

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle Rae; Thomas, Evan; Peterson, Laurie; Goforth, Johanna

    2008-01-01

    The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including: consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft flight under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.

  13. Preservation of urine samples for metabolic evaluation of stone-forming patients.

    PubMed

    Ferraz, Renato Ribeiro Nogueira; Baxmann, Alessandra Calábria; Ferreira, Larissa Gorayb; Nishiura, José Luiz; Siliano, Priscila Reina; Gomes, Samirah Abreu; Moreira, Silvia Regina Silva; Heilberg, Ita Pfeferman

    2006-10-01

    Metabolic evaluation of stone-forming (SF) patients is based on the determination of calcium, oxalate, citrate, uric acid and other parameters in 24-h urine samples under a random diet. A reliable measurement of urinary oxalate requires the collection of urine in a receptacle containing acid preservative. However, urinary uric acid cannot be determined in the same sample under this condition. Therefore, we tested the hypothesis that the addition of preservatives (acid or alkali) after urine collection would not modify the results of those lithogenic parameters. Thirty-four healthy subjects (HS) were submitted to two non-consecutive collections of 24-h urine. The first sample was collected in a receptacle containing hydrochloric acid (HCl 6 N) and the second in a dry plastic container, with HCl being added as soon as the urine sample was received at the laboratory. Additionally, 34 HS and 34 SF patients collected a spot urine sample that was divided into four aliquots, one containing HCl, another containing sodium bicarbonate (NaHCO(3 )5 g/l), and two others in which these two preservative agents were added 24 h later. Urinary oxalate, calcium, magnesium, citrate, creatinine and uric acid were determined. Urinary parameters were also evaluated in the presence of calcium oxalate or uric acid crystals. Mean values of all urinary parameters obtained from previously acidified 24-h urine samples did not differ from those where acid was added after urine collection. The same was true for spot urine samples, with the exception of urinary citrate that presented a slight albeit significant change of 5.9% between samples in HS and 3.1% in SF. Uric acid was also not different between pre- and post-alkalinized spot urine samples. The presence of crystals did not alter these results. We concluded that post-delivery acidification or alkalinization of urine samples does not modify the measured levels of urinary oxalate, calcium, magnesium, creatinine and uric acid, and that the

  14. The Recovery of Water and Nitrogen from Urine in BLSS

    NASA Astrophysics Data System (ADS)

    Xie, Beizhen; Liu, Hong; Deng, Shengda

    The recycle and reuse of the wastewater is one of the main factors for realizing a higher closure degree of bioregenerative life support system (BLSS), and the treatment and recovery of the crew’s urine are the most difficult and critical issues. Urine contains a lot of water and high concentrations of urea and salts. Water can be used for the irrigation of the plants in BLSS, and the nitrogen is also the necessary nutrient for plant growth. Therefore, if the nitrogen could be recycled simultaneously while desalting the urine, the substance circulation and the closure of BLSS could be improved significantly. In this study, two-step method was conducted to treat the urine and recycle the water and nitrogen. The urea was hydrolyzed firstly, and then the water vapor and ammonia gas were cooled and collected by using reduced pressure distillation in alkaline condition. High temperature acidification and urease processing methods were studied during the urea hydrolysis step. The treatment conditions of both methods were optimized and the degrees of hydrolysis were compared. This investigation may provide a reference for the establishment of the urine recycle in BLSS.

  15. RAMAN SPECTROSCOPY-BASED METABOLOMICS FOR DIFFERENTIATING EXPOSURES TO TRIAZOLE FUNGICIDES USING RAT URINE

    EPA Science Inventory

    Normal Raman spectroscopy was evaluated as a metabolomic tool for assessing the impacts of exposure to environmental contaminants, using rat urine collected during the course of a toxicological study. Specifically, one of three triazole fungicides, myclobutanil, propiconazole or ...

  16. EVALUATION OF DISPOSABLE DIAPERS FOR QUANTATIVE MEASUREMENTS OF PESTICIDE METABOLITES AND CREATININE IN URINE SAMPLES

    EPA Science Inventory

    This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...

  17. Detection of Zika Virus in Urine

    PubMed Central

    Gourinat, Ann-Claire; O’Connor, Olivia; Calvez, Elodie; Goarant, Cyrille

    2015-01-01

    We describe the kinetics of Zika virus (ZIKV) detection in serum and urine samples of 6 patients. Urine samples were positive for ZIKV >10 days after onset of disease, which was a notably longer period than for serum samples. This finding supports the conclusion that urine samples are useful for diagnosis of ZIKV infections. PMID:25530324

  18. Detection of Zika virus in urine.

    PubMed

    Gourinat, Ann-Claire; O'Connor, Olivia; Calvez, Elodie; Goarant, Cyrille; Dupont-Rouzeyrol, Myrielle

    2015-01-01

    We describe the kinetics of Zika virus (ZIKV) detection in serum and urine samples of 6 patients. Urine samples were positive for ZIKV >10 days after onset of disease, which was a notably longer period than for serum samples. This finding supports the conclusion that urine samples are useful for diagnosis of ZIKV infections.

  19. Managing Chemotherapy Side Effects: Urination Changes

    MedlinePlus

    ... nurse if you have any of these changes: l A strong urge to urinate more often l Urine that is cloudy, or is a different ... such as orange, red, green, or dark yellow l Urine that has a strong smell l Trouble ...

  20. Development of an In-line Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Branelle R.

    2009-01-01

    Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

  1. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  2. Excretion of arsenic in urine as a function of exposure to arsenic in drinking water.

    PubMed Central

    Calderon, R L; Hudgens, E; Le, X C; Schreinemachers, D; Thomas, D J

    1999-01-01

    Urinary arsenic (As) concentrations were evaluated as a biomarker of exposure in a U.S. population chronically exposed to inorganic As (InAs) in their drinking water. Ninety-six individuals who consumed drinking water with As concentrations of 8-620 microg/L provided first morning urine voids for up to 5 consecutive days. The study population was 56% male, and 44% was younger than 18 years of age. On one day of the study period, all voided urines were collected over a 24-hr period. Arsenic intake from drinking water was estimated from daily food diaries. Comparison between the concentration of As in individual urine voids with that in the 24-hr urine collection indicated that the concentration of As in urine was stable throughout the day. Comparison of the concentration of As in each first morning urine void over the 5-day study period indicated that there was little day-to-day variation in the concentration of As in urine. The concentration of As in drinking water was a better predictor of the concentration of As in urine than was the estimated intake of As from drinking water. The concentration of As in urine did not vary by gender. An age-dependent difference in the concentration of As in urine may be attributed to the higher As dosage rate per unit body weight in children than in adults. These findings suggest that the analysis of a small number of urine samples may be adequate to estimate an individual's exposure to InAs from drinking water and that the determination of the concentration of InAs in a drinking water supply may be a useful surrogate for estimating exposure to this metalloid. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:10417365

  3. Purple Urine Bag Syndrome in Two Elderly Men with Urinary Tract Infection.

    PubMed

    Van Keer, Jan; Detroyer, Daan; Bammens, Bert

    2015-01-01

    Purple urine bag syndrome is a rare condition in which purple discoloration of urine inside its collection bag occurs. We describe two illustrative cases. The first patient is an 81-year-old man who was hospitalized for a newly diagnosed lymphoma with acute obstructive renal failure for which a nephrostomy procedure was performed. During the hospitalization, a sudden purple discoloration of the suprapubic catheter urine was noted, while the nephrostomy urine had a normal color. Urine culture from the suprapubic catheter was positive for Pseudomonas aeruginosa and Enterococcus faecalis; urine from the nephrostomy was sterile. The second case is an 80-year-old man who was admitted for heart failure with cardiorenal dilemma and who was started on intermittent hemodialysis. There was a sudden purple discoloration of the urine in the collection bag from his indwelling catheter. He was diagnosed with an E. coli urinary infection and treated with amoxicillin and removal of the indwelling catheter. These two cases illustrate the typical characteristics of purple urine bag syndrome. PMID:26351597

  4. On-Demand Urine Analyzer

    NASA Technical Reports Server (NTRS)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  5. Urine markers of interstitial cystitis.

    PubMed

    Erickson, D R

    2001-06-01

    This article describes the current state of the art with regard to urine markers of interstitial cystitis (IC), and describes the areas that need continuing research. Articles referenced in MEDLINE that describe urine alterations in IC were reviewed. Additional articles were identified by cross-referencing. The different marker alterations were tabulated. The relevant articles were discussed, considering different purposes for urine markers including: (1) diagnosing IC; (2) confirming a specific pathophysiology for IC; and (3) predicting or following response to a specific treatment. Currently, 2 markers (glycoprotein-51 and antiproliferative factor [APF]) clearly separate IC and control subjects, with minimal overlap. Markers that correlate with specific bladder biopsy features include 1,4-methylimidazole acetic acid and eosinophil cationic protein (ECP), which correlate with mast cell density, and interleukin (IL)-6, which correlates with mononuclear inflammation. Markers that changed after treatment were as follows: (1) nitric oxide synthase and cyclic guanosine monophosphate increased with oral L-arginine; (2) ECP decreased with subcutaneous heparin; (3) prostaglandin E(2) and kallikrein decreased after bladder distention; (4) neutrophil chemotactic activity decreased after dimethyl sulfoxide; (5) IL-2 inhibitor decreased after oral nifedipine; (6) IL-2, IL-6, and IL-8 decreased after bacille Calmette-Guérin (BCG) vaccine; and (7) APF and heparin-binding epidermal growth factor changed to or toward normal levels after bladder distention or sacral nerve stimulation. A larger number of urine alterations have been reported, and a few are being pursued further by correlating with bladder biopsy findings or treatment responses. Further research is needed.

  6. Correlation between sodium and potassium excretion in 24- and 12-h urine samples.

    PubMed

    Mill, J G; Silva, A B T da; Baldo, M P; Molina, M C B; Rodrigues, S L

    2012-09-01

    Low-sodium and high-potassium diets have been recommended as an adjunct to prevention and treatment of hypertension. Analysis of these nutrients in 24-h urine has been considered the reference method to estimate daily intake of these minerals. However, 24-h urine collection is difficult in epidemiological studies, since urine must be collected and stored in job environments. Therefore, strategies for shorter durations of urine collection at home have been proposed. We have previously reported that collecting urine during a 12-h period (overnight) is more feasible and that creatinine clearance correlated strongly with that detected in 24-h samples. In the present study, we collected urine for 24 h divided into two 12-h periods (from 7:00 am to 7:00 pm and from 7:00 pm to 7:00 am next day). A sample of 109 apparently healthy volunteers aged 30 to 74 years of both genders working in a University institution was investigated. Subjects with previous myocardial infarction, stroke, renal insufficiency, and pregnant women were not included. Significant (P < 0.001) Spearman correlation coefficients (r s) were found between the total amount of sodium and potassium excreted in the urine collected at night and in the 24-h period (r s = 0.76 and 0.74, respectively). Additionally, the 12-h sodium and potassium excretions (means ± SD, 95% confidence interval) corresponded to 47.3 ± 11.2%, 95%CI = 45.3-49.3, and 39.3 ± 4.6%, 95%CI = 37.3-41.3, respectively, of the 24-h excretion of these ions. Therefore, these findings support the assumption that 12-h urine collected at night can be used as a reliable tool to estimate 24-h intake/excretion of sodium and potassium.

  7. Urine bag as a modern day matula.

    PubMed

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may give clue to presence of infections, medications, poisons, and hemolysis. Although worrisome to the patient, urine discoloration is mostly benign and resolves with removal of the offending agent. Twelve urine bags with discolored urine (and their predisposing causes) have been shown as examples. Urine colors (blue-green, yellow, orange, pink, red, brown, black, white, and purple) and their etiologies have been reviewed following a literature search in these databases: Pubmed, EBSCO, Science Direct, Proquest, Google Scholar, Springer, and Ovid.

  8. Urine Bag as a Modern Day Matula

    PubMed Central

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may give clue to presence of infections, medications, poisons, and hemolysis. Although worrisome to the patient, urine discoloration is mostly benign and resolves with removal of the offending agent. Twelve urine bags with discolored urine (and their predisposing causes) have been shown as examples. Urine colors (blue-green, yellow, orange, pink, red, brown, black, white, and purple) and their etiologies have been reviewed following a literature search in these databases: Pubmed, EBSCO, Science Direct, Proquest, Google Scholar, Springer, and Ovid. PMID:24959539

  9. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  10. Determination of struvite crystallization mechanisms in urine using turbidity measurement.

    PubMed

    Triger, Aurélien; Pic, Jean-Stéphane; Cabassud, Corinne

    2012-11-15

    Sanitation improvement in developing countries could be achieved through wastewater treatment processes. Nowadays alternative concepts such as urine separate collection are being developed. These processes would be an efficient way to reduce pollution of wastewater while recovering nutrients, especially phosphorus, which are lost in current wastewater treatment methods. The precipitation of struvite (MgNH(4)PO(4)∙6H(2)O) from urine is an efficient process yielding more than 98% phosphorus recovery with very high reaction rates. The work presented here aims to determine the kinetics and mechanisms of struvite precipitation in order to supply data for the design of efficient urine treatment processes. A methodology coupling the resolution of the population balance equation to turbidity measurement was developed, and batch experiments with synthetic and real urine were performed. The main mechanisms of struvite crystallization were identified as crystal growth and nucleation. A satisfactory approximation of the volumetric crystal size distribution was obtained. The study has shown the low influence on the crystallization process of natural organic matter contained in real urine. It has also highlighted the impact of operational parameters. Mixing conditions can create segregation and attrition which influence the nucleation rate, resulting in a change in crystals number, size, and thus final crystal size distribution (CSD). Moreover urine storage conditions can impact urea hydrolysis and lead to spontaneous struvite precipitation in the stock solution also influencing the final CSD. A few limits of the applied methodology and of the proposed modelling, due to these phenomena and to the turbidity measurement, are also discussed.

  11. Development of an Advanced Recycle Filter Tank Assembly for the ISS Urine Processor Assembly

    NASA Technical Reports Server (NTRS)

    Link, Dwight E., Jr.; Carter, Donald Layne; Higbie, Scott

    2010-01-01

    Recovering water from urine is a process that is critical to supporting larger crews for extended missions aboard the International Space Station. Urine is collected, preserved, and stored for processing into water and a concentrated brine solution that is highly toxic and must be contained to avoid exposure to the crew. The brine solution is collected in an accumulator tank, called a Recycle Filter Tank Assembly (RFTA) that must be replaced monthly and disposed in order to continue urine processing operations. In order to reduce resupply requirements, a new accumulator tank is being developed that can be emptied on orbit into existing ISS waste tanks. The new tank, called the Advanced Recycle Filter Tank Assembly (ARFTA) is a metal bellows tank that is designed to collect concentrated brine solution and empty by applying pressure to the bellows. This paper discusses the requirements and design of the ARFTA as well as integration into the urine processor assembly.

  12. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  13. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  14. Student support and perceptions of urine source separation in a university community.

    PubMed

    Ishii, Stephanie K L; Boyer, Treavor H

    2016-09-01

    Urine source separation, i.e., the collection and treatment of human urine as a separate waste stream, has the potential to improve many aspects of water resource management and wastewater treatment. However, social considerations must be taken into consideration for successful implementation of this alternative wastewater system. This work evaluated the perceptions of urine source separation held by students living on-campus at a major university in the Southeastern region of the United States. Perceptions were evaluated in the context of the Theory of Planned Behavior. The survey population represents one group within a community type (universities) that is expected to be an excellent testbed for urine source separation. Overall, respondents reported high levels of support for urine source separation after watching a video on expected benefits and risks, e.g., 84% indicated that they would vote in favor of urine source separation in residence halls. Support was less apparent when measured by willingness to pay, as 33% of respondents were unwilling to pay for the implementation of urine source separation and 40% were only willing to pay $1 to $10 per semester. Water conservation was largely identified as the most important benefit of urine source separation and there was little concern reported about the use of urine-based fertilizers. Statistical analyses showed that one's environmental attitude, environmental behavior, perceptions of support within the university community, and belief that student opinions have an impact on university decision makers were significantly correlated with one's support for urine source separation. This work helps identify community characteristics that lend themselves to acceptance of urine source separation, such as those related to environmental attitudes/behaviors and perceptions of behavioral control and subjective norm. Critical aspects of these alternative wastewater systems that require attention in order to foster public

  15. Clinical Practice Guideline for the Treatment of Intrinsic Circadian Rhythm Sleep-Wake Disorders: Advanced Sleep-Wake Phase Disorder (ASWPD), Delayed Sleep-Wake Phase Disorder (DSWPD), Non-24-Hour Sleep-Wake Rhythm Disorder (N24SWD), and Irregular Sleep-Wake Rhythm Disorder (ISWRD). An Update for 2015

    PubMed Central

    Auger, R. Robert; Burgess, Helen J.; Emens, Jonathan S.; Deriy, Ludmila V.; Thomas, Sherene M.; Sharkey, Katherine M.

    2015-01-01

    A systematic literature review and meta-analyses (where appropriate) were performed and the GRADE approach was used to update the previous American Academy of Sleep Medicine Practice Parameters on the treatment of intrinsic circadian rhythm sleep-wake disorders. Available data allowed for positive endorsement (at a second-tier degree of confidence) of strategically timed melatonin (for the treatment of DSWPD, blind adults with N24SWD, and children/ adolescents with ISWRD and comorbid neurological disorders), and light therapy with or without accompanying behavioral interventions (adults with ASWPD, children/adolescents with DSWPD, and elderly with dementia). Recommendations against the use of melatonin and discrete sleep-promoting medications are provided for demented elderly patients, at a second- and first-tier degree of confidence, respectively. No recommendations were provided for remaining treatments/ populations, due to either insufficient or absent data. Areas where further research is needed are discussed. Citation: Auger RR, Burgess HJ, Emens JS, Deriy LV, Thomas SM, Sharkey KM. Clinical practice guideline for the treatment of intrinsic circadian rhythm sleep-wake disorders: advanced sleep-wake phase disorder (ASWPD), delayed sleep-wake phase disorder (DSWPD), non-24-hour sleep-wake rhythm disorder (N24SWD), and irregular sleep-wake rhythm disorder (ISWRD). An update for 2015. J Clin Sleep Med 2015;11(10):1199–1236. PMID:26414986

  16. Optimization for Peptide Sample Preparation for Urine Peptidomics

    SciTech Connect

    Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan; Dai, Hong; Qian, Weijun; Camp, David G.; Sarwal, Minnie M.

    2014-02-25

    Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides and the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins

  17. A history of urine microscopy.

    PubMed

    Cameron, J Stewart

    2015-11-01

    The naked-eye appearance of the urine must have been studied by shamans and healers since the Stone Age, and an elaborate interpretation of so-called Uroscopy began around 600 AD as a form of divination. A 1000 years later, the first primitive monocular and compound microscopes appeared in the Netherlands, and along with many other objects and liquids, urine was studied from around 1680 onwards as the enlightenment evolved. However, the crude early instruments did not permit fine study because of chromatic and linear/spherical blurring. Only after complex multi-glass lenses which avoided these problems had been made and used in the 1820s in London by Lister, and in Paris by Chevalier and Amici, could urinary microscopy become a practical, clinically useful tool in the 1830s. Clinical urinary microscopy was pioneered by Rayer and his pupils in Paris (especially Vigla), in the late 1830s, and spread to UK and Germany in the 1840s, with detailed descriptions and interpretations of cells and formed elements of the urinary sediment by Nasse, Henle, Robinson and Golding Bird. Classes were held, most notably by Donné in Paris. After another 50 years, optical microscopy had reached its apogee, with magnifications of over 1000 times obtainable free of aberration, using immersion techniques. Atlases of the urinary sediment were published in all major European countries and in the US. Polarised light and phase contrast was used also after 1900 to study urine, and by the early 20th century, photomicroscopy (pioneered by Donné and Daguerre 50 years previously, but then ignored) became usual for teaching and recording. In the 1940s electron microscopy began, followed by detection of specific proteins and cells using immunofluorescent antibodies. All this had been using handheld methodology. Around 1980, machine-assisted observations began, and have dominated progress since.

  18. A history of urine microscopy.

    PubMed

    Cameron, J Stewart

    2015-11-01

    The naked-eye appearance of the urine must have been studied by shamans and healers since the Stone Age, and an elaborate interpretation of so-called Uroscopy began around 600 AD as a form of divination. A 1000 years later, the first primitive monocular and compound microscopes appeared in the Netherlands, and along with many other objects and liquids, urine was studied from around 1680 onwards as the enlightenment evolved. However, the crude early instruments did not permit fine study because of chromatic and linear/spherical blurring. Only after complex multi-glass lenses which avoided these problems had been made and used in the 1820s in London by Lister, and in Paris by Chevalier and Amici, could urinary microscopy become a practical, clinically useful tool in the 1830s. Clinical urinary microscopy was pioneered by Rayer and his pupils in Paris (especially Vigla), in the late 1830s, and spread to UK and Germany in the 1840s, with detailed descriptions and interpretations of cells and formed elements of the urinary sediment by Nasse, Henle, Robinson and Golding Bird. Classes were held, most notably by Donné in Paris. After another 50 years, optical microscopy had reached its apogee, with magnifications of over 1000 times obtainable free of aberration, using immersion techniques. Atlases of the urinary sediment were published in all major European countries and in the US. Polarised light and phase contrast was used also after 1900 to study urine, and by the early 20th century, photomicroscopy (pioneered by Donné and Daguerre 50 years previously, but then ignored) became usual for teaching and recording. In the 1940s electron microscopy began, followed by detection of specific proteins and cells using immunofluorescent antibodies. All this had been using handheld methodology. Around 1980, machine-assisted observations began, and have dominated progress since. PMID:26079823

  19. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  20. Characteristic Male Urine Microbiomes Associate with Asymptomatic Sexually Transmitted Infection

    PubMed Central

    Nelson, David E.; Van Der Pol, Barbara; Dong, Qunfeng; Revanna, Kashi V.; Fan, Baochang; Easwaran, Shraddha; Sodergren, Erica; Weinstock, George M.; Diao, Lixia; Fortenberry, J. Dennis

    2010-01-01

    Background The microbiome of the male urogenital tract is poorly described but it has been suggested that bacterial colonization of the male urethra might impact risk of sexually transmitted infection (STI). Previous cultivation-dependent studies showed that a variety of non-pathogenic bacteria colonize the urethra but did not thoroughly characterize these microbiomes or establish links between the compositions of urethral microbiomes and STI. Methodology/Findings Here, we used 16S rRNA PCR and sequencing to identify bacteria in urine specimens collected from men who lacked symptoms of urethral inflammation but who differed in status for STI. All of the urine samples contained multiple bacterial genera and many contained taxa that colonize the human vagina. Uncultivated bacteria associated with female genital tract pathology were abundant in specimens from men who had STI. Conclusions Urine microbiomes from men with STI were dominated by fastidious, anaerobic and uncultivated bacteria. The same taxa were rare in STI negative individuals. Our findings suggest that the composition of male urine microbiomes is related to STI. PMID:21124791