Science.gov

Sample records for 24-hr urine sample

  1. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-hr urine samples for 50 adults in North Carolina

    EPA Science Inventory

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study ...

  2. Energy expenditures in four men estimated by D/sub 2/ /sup 18/O method at two times. I. From 24 hr urine samples

    SciTech Connect

    Bodwell, C.E.; Miles, C.W.; Seale, J.L.; Canary, J.J.; Prather, E.S.

    1986-03-01

    Four men (I-IV) were fed controlled diets with adjustment of energy intakes until body weights were constant for 3 wks (fall (F)) or 2 wks (spring (S)) and then maintained on the same diets for 3-4 weeks after dosing with D/sub 2/ /sup 18/O. Disappearances of D and /sup 18/O, measured in 24 hour urine (21 days), were used to estimate energy expenditures (EE) compared to metabolizable energy intakes (EI) needed to maintain body wt. EI were obtained from gross energy values (bomb calorimetry) of diet composites corrected for fecal and urinary losses. One subject (IV) consumed ETOH (18-20% of total calories). Among subjects, daily EI varied from 2500 to 3100 Kcal; 21-day mean +/-S.D. body wts. were (I) 66.3 +/- 0.3(F), 67.2 +/- 0.3(S); (II) 73.6 +/- 0.2(F), 74.2 +/- 0.3 (S); (III) 80.2 +/- 0.3(F), 77.6 +/- 0.4(S); (IV) 69.4 +/- 0.4(F), 70.7 +/- 0.4(S). For I and II, F and S intakes and EE values were similar; for III, S values were lower than F values. Small changes in body composition were observed; allowing for these altered relations between EE and EI. EE values were anomalous for IV; for subjects with high intake levels of fluids/ETOH, special methodology may be needed.

  3. Assessing Children’s Dietary Pesticide Exposure: Direct Measurement of Pesticide Residues in 24-Hr Duplicate Food Samples

    PubMed Central

    Lu, Chensheng; Schenck, Frank J.; Pearson, Melanie A.; Wong, Jon W.

    2010-01-01

    Background The data presented here are a response to calls for more direct measurements of pesticide residues in foods consumed by children and provide an opportunity to compare direct measures of pesticide residues in foods representing actual consumption with those reported by the U.S. Department of Agriculture Pesticide Data Program. Objective We measured pesticide residues in 24-hr duplicate food samples collected from a group of 46 young children participating in the Children’s Pesticide Exposure Study (CPES). Methods Parents were instructed to collect 24-hr duplicate food samples of all conventional fruits, vegetables, and fruit juices equal to the quantity consumed by their children, similarly prewashed/prepared, and from the same source or batch. Individual or composite food items were analyzed for organophosphate (OP) and pyrethroid insecticide residues. Results We collected a total of 239 24-hr duplicate food samples collected from the 46 CPES children. We found 14% or 5% of those food samples contained at least one OP or pyrethroid insecticide, respectively. We measured a total of 11 OP insecticides, at levels ranging from 1 to 387 ng/g, and three pyrethroid insecticides, at levels ranging from 2 to 1,133 ng/g, in children’s food samples. We found that many of the food items consumed by the CPES children were also on the list of the most contaminated food commodities reported by the Environmental Working Group. Conclusions The frequent consumption of food commodities with episodic presence of pesticide residues that are suspected to cause developmental and neurological effects in young children supports the need for further mitigation. PMID:20639183

  4. Urine sample (image)

    MedlinePlus

    ... catch" urine sample is performed by collecting the sample of urine in midstream. Men or boys should wipe clean the head of the penis. Women or girls need to wash the area between the lips of the vagina with soapy water and rinse well. A small amount of urine ...

  5. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  6. Urine sample collection protocols for bioassay samples

    SciTech Connect

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  7. Human performance and physiological function during a 24-hr exposure to 1% bromotrifluoromethane (Halon 1301)

    NASA Technical Reports Server (NTRS)

    Calkins, D. S.; Degioanni, J. J.; Tan, M. N.; Davis, J. R.; Pierson, D. L.

    1993-01-01

    Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1% (10,000 ppm) Halon 1301 (bromotrifluoromethane, CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5% of baseline values. Physiological data were obtained before, during, and after the exposures from clinical chemistry analyses of blood and urine samples, pulmonary function tests, and monitoring of vital signs. Significant change during Halon inhalation was observed for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1% Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

  8. Quantitation of proteinuria by spot urine sampling.

    PubMed

    Agarwal, Indira; Kirubakaran, Chellam; Markandeyulu; Selvakumar

    2004-07-01

    Few studies have shown that calculation of protein/creatinine ratio in a spot urine sample correlates well with the 24-hour urine collection. A study was conducted to compare the accuracy of a spot urinary protein/creatinine ratio (P/C ratio) and urinary dipstick (albustix) with the 24-hour urine protein (24-HUP). Fifty samples from 26 patients were collected. This included a 24-hour urine sample followed by the next voided spot sample. The protein/creatinine ratio was calculated and dipstick (albustix) was performed on the spot sample. This was compared with the 24-hour urine protein excretion. The correlation between the three samples was statistically highly significant (p=<0.001) for all levels of proteinuria. The normal value of protein/creatinine ratio in Indian children was also estimated on 100 normal children attending the OPD and was calculated to be 0.053 (S.E of mean±0.003). PMID:23105455

  9. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure for young children wearing diapers, a method for collecting urine samples for analysis of pesticide metabolites is needed. To find a practical method, two possibilities were investigated: (1) analysis of expressed urine from cotton diaper inserts ...

  10. Energy expenditures in four men estimated by D/sub 2/ /sup 18/O method at two times. II. From once daily samples of urine or breath

    SciTech Connect

    Miles, C.W.; Seale, J.L.; Collins, J.S.; Barnes, R.; Canary, J.J.; Bodwell, C.E.

    1986-03-01

    To make the doubly labelled water method for determining energy expenditure more applicable in a free-living population, collection of a single daily urine or breath sample would have advantages compared to a 24-hr urine collection. Coward et al. reported the use of a single daily urine sample. In the previously described study, a single urine collection and a fasting morning breath sample were collected from four men during two 21-day periods (fall, F, spring, S) while maintaining their body wts. on controlled diets (20% calories from protein, 40% from fat, 60% from CHO (F); 20% protein, 20% fat, 60% CHO (S)). Urine and breath samples were analyzed to determine disappearance rates of D and /sup 18/O for up to 21 days. Values were compared with metabolizable energy intake levels (EI), with or without corrections for estimated changes in body composition assessed by several methods. Preliminary evaluations suggest that the single daily urine sample values may overestimate and values from the fasting breath samples may underestimate energy expenditure compared to EI.

  11. NEW COLUMN SEPARATION METHOD FOR EMERGENCY URINE SAMPLES

    SciTech Connect

    Maxwell, S; Brian Culligan, B

    2007-08-28

    The Savannah River Site Environmental Bioassay Lab participated in the 2007 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2007. A new rapid column separation method was applied directly to the NRIP 2007 emergency urine samples, with only minimal sample preparation to reduce preparation time. Calcium phosphate precipitation, previously used to pre-concentrate actinides and Sr-90 in NRIP 2006 urine and water samples, was not used for the NRIP 2007 urine samples. Instead, the raw urine was acidified and passed directly through the stacked resin columns (TEVA+TRU+SR Resins) to separate the actinides and strontium from the NRIP urine samples more quickly. This improvement reduced sample preparation time for the NRIP 2007 emergency urine analyses significantly. This approach works well for small volume urine samples expected during an emergency response event. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and strontium-90 analyses for NRIP 2007 urine samples.

  12. Automated biowaste sampling system urine subsystem operating model, part 1

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Mangialardi, J. K.; Rosen, F.

    1973-01-01

    The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.

  13. Rapid determination of 226Ra in emergency urine samples

    DOE PAGESBeta

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.; Utsey, Robin C.; McAlister, Daniel R.

    2014-02-27

    A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed.more » The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.« less

  14. Urine sampling and collection system optimization and testing

    NASA Technical Reports Server (NTRS)

    Fogal, G. L.; Geating, J. A.; Koesterer, M. G.

    1975-01-01

    A Urine Sampling and Collection System (USCS) engineering model was developed to provide for the automatic collection, volume sensing and sampling of urine from each micturition. The purpose of the engineering model was to demonstrate verification of the system concept. The objective of the optimization and testing program was to update the engineering model, to provide additional performance features and to conduct system testing to determine operational problems. Optimization tasks were defined as modifications to minimize system fluid residual and addition of thermoelectric cooling.

  15. Optimization for Peptide Sample Preparation for Urine Peptidomics

    SciTech Connect

    Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan; Dai, Hong; Qian, Weijun; Camp, David G.; Sarwal, Minnie M.

    2014-02-25

    Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides and the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins

  16. Spectrophotometric determination of sparfloxacin in pharmaceutical formulations and urine samples

    NASA Astrophysics Data System (ADS)

    Jan, M. R.; Shah, J.; Inayatullah

    2010-07-01

    A simple and sensitive spectrophotometric method has been developed for the determination of sparfloxacin in bulk and pharmaceutical formulations, and in artificial urine. Sparfloxacin was oxidized into a red colored product using ammonium monovanadate in acidic media. The proposed method was successfully applied to the determination of sparfloxacin in different pharmaceutical formulations (tablets) and in a spiked urine sample. The influence of commonly used excipients on the determination of sparfloxacin was studied. Percentage recoveries in the range of 98.0 ± 0.14 % to 100.0 ± 0.20 % were obtained. The observed data have been evaluated statistically which showed high accuracy and precision.

  17. Radionuclide analyses of urine samples: results of an intercomparison

    NASA Astrophysics Data System (ADS)

    Dalheimer, A. R.; Beyer, D.; Günther, E. W.; Henrichs, K.

    1996-02-01

    The measurement of radioactivity concentrations in urine samples is an important tool for monitoring possible radionuclide intakes by occupationally exposed workers, especially for radionuclides emitting alpha or beta radiation. Quality assurance requires systematic intercomparisons involving all laboratories responsible for these measurements. Such analyses were performed by the German—Swiss Radiation Protection Association. The main purpose of these measurements was the specification of criteria for the acceptance of laboratories by radiation protection authorities. This contribution presents some measurement results of Th-nat, 90Sr, and 241Am in urine and discusses the implications for internal dosimetry.

  18. Urine sample used for congenital toxoplasmosis diagnosis by PCR.

    PubMed Central

    Fuentes, I; Rodriguez, M; Domingo, C J; del Castillo, F; Juncosa, T; Alvar, J

    1996-01-01

    The diagnosis of toxoplasmosis in congenitally infected infants can be difficult; serology is unreliable, and diagnosis must be based on the combination of symptomatology and direct demonstration of the parasite. Four infants suspected of having Toxoplasma gondii infection were studied by serological analysis, tissue culture, and PCR determination. T. gondii was isolated from the urine of one patient. The parasite was detected by PCR in the blood and cerebrospinal fluid of three infants and in the urine in all patients. Because nested PCR proved to be a sensitive, relatively rapid, and specific method and because it can be applied to a variety of different clinical samples, PCR can be a valuable technique for the identification of T. gondii infections in children. The present study indicates that PCR examination of urine, a fluid never before used for diagnosis in this age group, may be valuable in diagnosing cases of congenital toxoplasmosis. PMID:8880481

  19. RAPID ANALYSIS OF EMERGENCY URINE AND WATER SAMPLES

    SciTech Connect

    Maxwell, S

    2007-02-26

    There is a need for fast, reliable methods for the determination of actinides and Sr-89/90 analysis on environmental and bioassay samples in response to an emergency radiological incident. The SRS (Savannah River Site) Environmental Bioassay Laboratory participated in the National Institute of Standards and Technology Radiochemistry Intercomparison Program (NRIP-06) and analyzed water and urine samples within 8 hours of receipt. The SRS Environmental Laboratory was the only lab that participated in the program that analyzed these samples for both actinides and Sr-89/90 within the requested 8 hour turnaround time. A new, rapid actinide and strontium 89/90 separation method was used for both urine and water samples. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and Sr-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), and americium (Am), curium (Cm) and thorium (Th) using a single multi-stage column combined with alpha spectrometry. By using vacuum box cartridge technology and stacked cartridges with rapid flow rates, sample preparation time was minimized. This paper discusses the technology and conditions employed for both water and urine samples and presents the SRS performance data on the NRIP-06 samples.

  20. Determination of actinides in urine and fecal samples

    SciTech Connect

    McKibbin, T.T.

    1992-12-31

    A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.

  1. Determination of actinides in urine and fecal samples

    DOEpatents

    McKibbin, Terry T.

    1993-01-01

    A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.

  2. Determination of actinides in urine and fecal samples

    DOEpatents

    McKibbin, T.T.

    1993-03-02

    A method of determining the radioactivity of specific actinides that are carried in urine or fecal sample material is disclosed. The samples are ashed in a muffle furnace, dissolved in an acid, and then treated in a series of steps of reduction, oxidation, dissolution, and precipitation, including a unique step of passing a solution through a chloride form anion exchange resin for separation of uranium and plutonium from americium.

  3. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    SciTech Connect

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  4. Method for actinides and Sr-90 determination in urine samples.

    PubMed

    Alvarez, A; Navarro, N

    1996-01-01

    The primary goal of radiation protection in decommissioning and decontamination of the old nuclear facilities of the CIEMAT is to monitor and minimize exposure of personnel. Monitoring programs include determination of actinides and 90Sr in biological samples. A technique for the sequential measurement of low levels of 239Pu, 241Am and 90Sr in urine samples has been developed. The method involves coprecipitation of these radionuclides as phosphates from bulk urine sample. Separation of Plutonium is carried out using a conventional anion exchange technique. Americium and strontium isolations are achieved sequentially by chromatographic extraction (Tru.Spec and Sr.Spec columns) from the load and rinse solutions coming from the anion exchange column. Plutonium and Americium measurements are performed by alpha spectrometry. The mean recovery obtained is 80% and the detection limit for 24 h urine sample (1.41) is 0.6 mBq L-1. 90Sr determination is made by liquid scintillation counting. The detection limit in this case is 1.1 E-01 Bq/L. PMID:8976042

  5. [Isolation frequency of the Mycobacterium genus in urine samples].

    PubMed

    Mederos, Lilian M; Sardiñas, Misleidis; García, Grechen; Martínez, María Rosarys; Reyes, Angélica; Díaz, Raúl

    2015-10-01

    Kidney infections caused by Mycobacterium genus are torpid and chronic evolution. In this study were analyzed 177 urine samples (included 110 from HIV patients) received between January 2006 and July 2014 in the National Reference Laboratory of Tuberculosis at Tropical Medicine Institute "Pedro Kourí" (IPK). The results were 17 isolates Mycobacterium tuberculosis, and 30 isolates of nontuberculous mycobacteria were detected. This study confirms the diagnostic importance of these infections especially in HIV/AIDS patients. PMID:26633121

  6. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF URINE SAMPLES (SOP-2.14)

    EPA Science Inventory

    This SOP describes the method for collecting urine samples from the study participants (children and their primary caregivers). Urine samples will be approximate 48-hr collections, collected as spot urine samples accumulated over the 48-hr sampling period. If the household or da...

  7. Improving Urine Sample Efficacy as a Convenient Alternative for Invasive Samples in Molecular Diagnosis of Toxoplasmosis

    PubMed Central

    Eskandarian, AA

    2013-01-01

    Background Diagnosis of some diseases is difficult due to invasive sampling. Urine has been candidate as a non-invasive and convenient alternative. It has many advantages and easy accessibility but some technical ills should be removed. Finding a suitable extraction method for improving urine DNA quantity and quality in altering invasive specimens for molecular diagnosis of some infectious diseases, was the main object of present research. Method Toxoplasmosis was selected as an experimental model, regarding the congenital and ocular forms, its abundance and requirement to invasive sample for diagnosis. Samples prepared by adding some defined Toxoplasma gondii (RH strain) tachyzoites to normal urine. Several urine DNA extraction and purification methods comparatively were tested for finding the best one. The amount of extracted DNA assessed using Nanodrope spectrophotometer and a multiplex semi-nested PCR were designed for evaluating the results. Results Urine samples with known number of tachyzoites were purified comparatively by five better methods. The results reviled that Cinnagen kit performed with more efficacies. It works well up to 1-5tachyzoites µl−1 of urine. The amount and quality of extracted DNA of more than 100 urine samples with defined tachyzoites were analyzed using a nested PCR method. Finally methods were enough sensitive to detect one tachyzoite DNA in final PCR reaction. Conclusion This method was enough eligible and sensitive to perform molecular tests for different purposes of instance detecting toxoplasmosis by urine sample as a convenience and non invasive method; although it is better to perform some more experiments using patients samples comparing gold methods. PMID:23682277

  8. Human performance and physiological function during a 24-hr exposure to 1 percent bromotrifluoromethane (Halon 1301)

    NASA Technical Reports Server (NTRS)

    Calkins, D. S.; Degioanni, J. J.; Tan, M. N.; Davis, J. R.; Pierson, D. L.

    1993-01-01

    Performance and physiological measurements were obtained from four pairs of men exposed for 24 hr to 1 percent (10,000 ppm) Halon 1301 (CBrF3) and to air with order counterbalanced using a double-blind protocol. Cognitive and motor performance was assessed before, during, and after the exposures, using seven scales of the Automated Portable Testing System, which produced 13 measures of performance. Halon inhalation induced decrements in 2 of the 13 measures, but actual and estimated magnitudes of the decrements were no greater than 5 percent of baseline values. Physiological data obtained before, during, and after the exposures revealed significant changes during Halon inhalation for 6 of the 52 variables assessed; however, all physiological values remained within clinically acceptable limits. No cardiovascular effects were noted. This study demonstrated that exposure to 1 percent Halon 1301 for 24 hr can produce minor disturbance of central nervous system function as assessed by cognitive tasks.

  9. Simpler spectrophotometric assay of paracetamol in tablets and urine samples

    NASA Astrophysics Data System (ADS)

    Sirajuddin; Khaskheli, Abdul Rauf; Shah, Afzal; Bhanger, Muhammad Iqbal; Niaz, Abdul; Mahesar, Sarfaraz

    2007-11-01

    A very fast, economical and simpler direct spectrophotometric method was investigated for paracetamol (PC) determination in aqueous medium without using any chemical reagents. The method is based on the photo-absorption of the analyte at 243 nm after dissolution in water. The change in structure of PC after addition of water was studied by comparing the corresponding FTIR spectra. Optimization studies were conducted by using a 5 μg ml -1 standard solution of the analyte. Various parameters studied include, time for stability and measurement of spectra, effect of HCl, NaOH, CH 3COOH and NH 3 for change in absorbance and shift in spectra, interference by some analgesic drugs and some polar solvents and temperature effect. After optimization, Beer's law was obeyed in the range of 0.3-20 μg ml -1 PC solution with a correlation coefficient of 0.9999 and detection limit of 0.1 μg ml -1. The newly developed method was successfully applied for PC determination in some locally available tablets and urine samples. The proposed method is very useful for quick analysis of various types of solid and liquid samples containing PC.

  10. Proteomic analysis of a podocyte vesicle-enriched fraction from human normal and pathological urine samples.

    PubMed

    Lescuyer, Pierre; Pernin, Agnès; Hainard, Alexandre; Bigeire, Caty; Burgess, Jennifer A; Zimmermann-Ivol, Catherine; Sanchez, Jean-Charles; Schifferli, Jürg A; Hochstrasser, Denis F; Moll, Solange

    2008-07-01

    Podocytes (glomerular visceral epithelial cells) release vesicles into urine. Podocyte vesicle-enriched fractions from normal and pathological human urine samples were prepared for proteomic analysis. An immunoadsorption method was applied and enrichment of podocyte vesicles was assessed. We identified 76 unique proteins. One protein, serum paraoxonase/arylesterase 1 (PON-1), was newly identified in normal human urine sample. We confirmed this result and showed PON-1 expression in normal human kidney. These results demonstrated the potential for using the urine samples enriched in podocyte vesicles as a starting material in studies aimed at discovery of biomarkers for diseases. PMID:21136901

  11. Single-Source Gravitational Wave Limits From the J1713+0747 24-hr Global Campaign

    NASA Astrophysics Data System (ADS)

    Dolch, T.; NANOGrav Collaboration; Ellis, J. A.; Chatterjee, S.; Cordes, J. M.; Lam, M. T.; Bassa, C.; Bhattacharyya, B.; Champion, D. J.; Cognard, I.; Crowter, K.; Demorest, P. B.; Hessels, J. W. T.; Janssen, G.; Jenet, F. A.; Jones, G.; Jordan, C.; Karuppusamy, R.; Keith, M.; Kondratiev, V. I.; Kramer, M.; Lazarus, P.; Lazio, T. J. W.; Lorimer, D. R.; Madison, D. R.; McLaughlin, M. A.; Palliyaguru, N.; Perrodin, D.; Ransom, S. M.; Roy, J.; Shannon, R. M.; Smits, R.; Stairs, I. H.; Stappers, B. W.; Stinebring, D. R.; Stovall, K.; Verbiest, J. P. W.; Zhu, W. W.

    2016-05-01

    Dense, continuous pulsar timing observations over a 24-hr period provide a method for probing intermediate gravitational wave (GW) frequencies from 10 microhertz to 20 millihertz. The European Pulsar Timing Array (EPTA), the North American Nanohertz Observatory for Gravitational Waves (NANOGrav), the Parkes Pulsar Timing Array (PPTA), and the combined International Pulsar Timing Array (IPTA) all use millisecond pulsar observations to detect or constrain GWs typically at nanohertz frequencies. In the case of the IPTA's nine-telescope 24-Hour Global Campaign on millisecond pulsar J1713+0747, GW limits in the intermediate frequency regime can be produced. The negligible change in dispersion measure during the observation minimizes red noise in the timing residuals, constraining any contributions from GWs due to individual sources. At 10-5 Hz, the 95% upper limit on strain is 10-11 for GW sources in the pulsar's direction.

  12. Bioanalysis of urine samples after manipulation by oxidizing chemicals: technical considerations.

    PubMed

    Fu, Shanlin; Luong, Susan; Pham, Annie; Charlton, Nathan; Kuzhiumparambil, Unnikrishnan

    2014-06-01

    Drug testing programs are established to help achieve a drug-free work environment, promote fair competition in sport, facilitate harm minimization and rehabilitation programs, better manage patient care by clinicians and service law enforcement authorities. Urine remains the most popular and appropriate testing matrix for such purposes. However, urine is prone to adulteration, where chemicals, especially oxidizing chemicals, are purposely added to the collected urine specimens to produce a false-negative test result. This article will describe the effect of various popular oxidizing adulterants on urine drug test results, the countermeasures taken by laboratories in dealing with adulterated urine samples and the prospect of developing more robust and economical methods to combat urine adulteration in the future. PMID:25046053

  13. Urine concentrations of oral salbutamol in samples collected after intense exercise in endurance athletes.

    PubMed

    Hostrup, Morten; Kalsen, Anders; Auchenberg, Michael; Rzeppa, Sebastian; Hemmersbach, Peter; Bangsbo, Jens; Backer, Vibeke

    2014-06-01

    Our objective was to investigate urine concentrations of 8 mg oral salbutamol in samples collected after intense exercise in endurance athletes. Nine male endurance athletes with a VO2max of 70.2 ± 5.9 mL/min/kg (mean ± SD) took part in the study. Two hours after administration of 8 mg oral salbutamol, subjects performed submaximal exercise for 15 min followed by two, 2-min exercise bouts at an intensity corresponding to 110% of VO2max and a bout to exhaustion at same intensity. Urine samples were collected 4, 8, and 12 h following administration of salbutamol. Samples were analyzed by the Norwegian World Anti-doping Agency (WADA) laboratory. Adjustment of urine concentrations of salbutamol to a urine specific gravity (USG) of 1.020 g/mL was compared with no adjustment according to WADA's technical documents. We observed greater (P = 0.01) urine concentrations of salbutamol 4 h after administration when samples were adjusted to a USG of 1.020 g/mL compared with no adjustment (3089 ± 911 vs. 1918 ± 1081 ng/mL). With the current urine decision limit of 1200 ng/mL for salbutamol on WADA's 2013 list of prohibited substances, fewer false negative urine samples were observed when adjusted to a USG of 1.020 g/mL compared with no adjustment. In conclusion, adjustment of urine samples to a USG of 1.020 g/mL decreases risk of false negative doping tests after administration of oral salbutamol. Adjusting urine samples for USG might be useful when evaluating urine concentrations of salbutamol in doping cases. PMID:24166762

  14. New sorbent materials for selective extraction of cocaine and benzoylecgonine from human urine samples.

    PubMed

    Bujak, Renata; Gadzała-Kopciuch, Renata; Nowaczyk, Alicja; Raczak-Gutknecht, Joanna; Kordalewska, Marta; Struck-Lewicka, Wiktoria; Waszczuk-Jankowska, Małgorzata; Tomczak, Ewa; Kaliszan, Michał; Buszewski, Bogusław; Markuszewski, Michał J

    2016-02-20

    An increase in cocaine consumption has been observed in Europe during the last decade. Benzoylecgonine, as a main urinary metabolite of cocaine in human, is so far the most reliable marker of cocaine consumption. Determination of cocaine and its metabolite in complex biological samples as urine or blood, requires efficient and selective sample pretreatment. In this preliminary study, the newly synthesized sorbent materials were proposed for selective extraction of cocaine and benzoylecgonine from urine samples. Application of these sorbent media allowed to determine cocaine and benzoylecgonine in urine samples at the concentration level of 100ng/ml with good recovery values as 81.7%±6.6 and 73.8%±4.2, respectively. The newly synthesized materials provided efficient, inexpensive and selective extraction of both cocaine and benzoylecgonine from urine samples, which can consequently lead to an increase of the sensitivity of the current available screening diagnostic tests. PMID:26689741

  15. Conceptual Design of a Vertical Takeoff and Landing Unmanned Aerial Vehicle with 24-HR Endurance

    NASA Technical Reports Server (NTRS)

    Fredericks, William J.

    2010-01-01

    This paper describes a conceptual design study for a vertical takeoff and landing (VTOL) unmanned aerial vehicle (UAV) that is able to carry a 25-lb science payload for 24 hr and is able to land and take off at elevations as high as 15,000 ft without human intervention. In addition to the science payload, this vehicle must be able to carry a satellite communication system, and the vehicle must be able to be transported in a standard full-size pickup truck and assembled by only two operators. This project started with a brainstorming phase to devise possible vehicle configurations that might satisfy the requirements. A down select was performed to select a near-term solution and two advanced vehicle concepts that are better suited to the intent of the mission. Sensitivity analyses were also performed on the requirements and the technology levels to obtain a better understanding of the design space. This study found that within the study assumptions the mission is feasible; the selected concepts are recommended for further development.

  16. Anatomical observations of the rat cerebellar nodulus after 24 hr of spaceflight.

    PubMed

    Holstein, G R; Kukielka, E; Martinelli, G P

    1999-07-01

    Exposure to microgravity causes alterations in postural, locomotor and oculomotor functions. The vestibular abnormalities experienced by astronauts entail immediate reflex motor responses, including postural illusions, sensations of rotation, nystagmus, dizziness and vertigo, as well as space motion sickness. Adaptation to the microgravity environment usually occurs within one week, and a subsequent re-adaptation period of several months is often required upon return to Earth. Some astronauts experience recurrences of dizziness, nausea, and vomiting, as well as marked disturbances in postural equilibrium in the absence of vision during this readaptation period. The mechanisms underlying such adaptation processes remain unclear, although current evidence favors some type of sensory conflict. The purpose of the present study was to explore the structural basis for the reorganization in the central vestibular system that underlies the process of adaptation to altered gravitational environments. Hindbrain tissue was obtained from rats flown on the Neurolab shuttle mission (STS-90) that launched on April 17, 1998. Tissue for the present report was obtained from four adult Fisher 344 rats sacrificed on orbit during flight day 2 (FD2), 24 hr after launch. Equal numbers of vivarium control animals and cage-controls were sacrificed 48 and 96 hr, respectively, after the flight dissections. Following decapitation, each hindbrain was immersion-fixed for 45 min in 4% paraformaldehyde/0.1% glutaraldehyde in 0.1M phosphate buffer pH 7.3, and then transferred to a 4% paraformaldehyde solution in 0.1M phosphate buffer for 18 days at 4 degrees C. After this fixation, the cerebellum was dissected away from the ventral portion of the brainstem by severing the cerebellar peduncles. The entire cerebellum of each rat was cut by Vibratome into 100 micrometers thick sections in the parasagittal plane. These sections were collected serially and processed for electron microscopy by

  17. Determination of 226Ra in urine samples by alpha spectrometry.

    PubMed

    Kehagia, K; Potiriadis, C; Bratakos, S; Koukouliou, V; Drikos, G

    2007-01-01

    A radiation protection system to assess the internal contamination of workers during decontamination activities in an abounded fertilizer industry in the region of Attika, Greece, has been implemented. This system concerns, among other radionuclides, 226Ra. Because of the low 226Ra activities in urine, alpha spectrometry was used as the determination method after radiochemical separation. Radium was co precipitated with lead sulphate and purified using anion and cation exchange techniques. The source for the alpha spectrometric measurement was prepared by the electrodeposition of radium, from an aqueous/ethanol solution, onto stainless steel. The tracer used was 229Th. The chemical yield and the activity concentration were calculated via its daughter radionuclide 217At. Using the time-evolution formulas to calculate the 217At growth from its parent radionuclide 225Ra, a computer software was developed. This software was incorporated in a database, which automatically calculates and stores the results. PMID:17827131

  18. Excretion of arsenic in urine as a function of exposure to arsenic in drinking water.

    PubMed Central

    Calderon, R L; Hudgens, E; Le, X C; Schreinemachers, D; Thomas, D J

    1999-01-01

    Urinary arsenic (As) concentrations were evaluated as a biomarker of exposure in a U.S. population chronically exposed to inorganic As (InAs) in their drinking water. Ninety-six individuals who consumed drinking water with As concentrations of 8-620 microg/L provided first morning urine voids for up to 5 consecutive days. The study population was 56% male, and 44% was younger than 18 years of age. On one day of the study period, all voided urines were collected over a 24-hr period. Arsenic intake from drinking water was estimated from daily food diaries. Comparison between the concentration of As in individual urine voids with that in the 24-hr urine collection indicated that the concentration of As in urine was stable throughout the day. Comparison of the concentration of As in each first morning urine void over the 5-day study period indicated that there was little day-to-day variation in the concentration of As in urine. The concentration of As in drinking water was a better predictor of the concentration of As in urine than was the estimated intake of As from drinking water. The concentration of As in urine did not vary by gender. An age-dependent difference in the concentration of As in urine may be attributed to the higher As dosage rate per unit body weight in children than in adults. These findings suggest that the analysis of a small number of urine samples may be adequate to estimate an individual's exposure to InAs from drinking water and that the determination of the concentration of InAs in a drinking water supply may be a useful surrogate for estimating exposure to this metalloid. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:10417365

  19. Urine sample preparation in 96-well filter plates for quantitative clinical proteomics.

    PubMed

    Yu, Yanbao; Suh, Moo-Jin; Sikorski, Patricia; Kwon, Keehwan; Nelson, Karen E; Pieper, Rembert

    2014-06-01

    Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ~10 μg of total protein were processed by 96FASP and LC-MS resulting in 700-900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144

  20. [Can examination of spontaneous urine samples adequately replace 24-hour-urine samples for determining excretory rate of various lithogenic and inhibitory substances in metabolic evaluation of kidney calculi patients?].

    PubMed

    Brändle, E; Melzer, H; Gomez-Anson, B; Flohr, P; Kleinschmidt, K; Sieberth, H G; Hautmann, R E

    1996-03-01

    The gold standard for metabolic evaluation of stone-forming patients is the 24-h urine specimen. Recently, some authors have suggested that for routine metabolic evaluation spot urine samples are as valuable as the 24-h urine specimen. The purpose of our study, was to determine the value of the spot urine sample in comparison with the 24-h urine specimens. Eighty-eight healthy volunteers on different diets were investigated (32 vegetarians, 12 body-builders without protein concentrates, 28 body-builders on protein concentrates, and 16 subjects on a regular European diet). Using 24-h specimens, excretion rates of oxalate, calcium, sodium and potassium were determined. The concentration ratio of these electrolytes to creatinine was calculated for spot urine samples. A highly significant correlation between the excretion rates and the results of the spot urine samples was found for all parameters. However, the correlations showed considerable variations. On the other hand, we were able to show that creatinine excretion is highly dependent on daily protein intake, body weight and glomerular filtration rate. This leads to a considerable inter- and intraindividual variation in creatinine excretion. This variation of the creatinine excretion is the major cause for the variation in the results of spot urine samples. It is concluded that spot urine samples are an inadequate substitute for the 24-h urine specimen and that the 24-h urine specimen is still the basis for metabolic evaluation in stone patients. PMID:8650847

  1. Elevated formic acid concentrations in putrefied post-mortem blood and urine samples.

    PubMed

    Viinamäki, Jenni; Rasanen, Ilpo; Vuori, Erkki; Ojanperä, Ilkka

    2011-05-20

    Formic acid (FA) concentration was measured in post-mortem blood and urine samples as methyl formate using a headspace in-tube extraction gas-chromatography-mass-spectrometry method. A total of 113 cases were analyzed, each including a blood and urine sample fortified with 1% sodium fluoride. The cases were divided into three groups: regular (n=59), putrefied (n=30), and methanol-positive (n=22) cases. There was no evidence of ante-mortem methanol consumption in the regular and putrefied cases. In regular cases, the mean (and median) FA concentrations were 0.04 g/l (0.04 g/l) and 0.06 g/l (0.04 g/l) in blood and urine, respectively. In putrefied cases, the mean (and median) FA concentrations were substantially higher, 0.24 g/l (0.22 g/l) and 0.25 g/l (0.15 g/l) in blood and urine, respectively. In three putrefied cases, FA concentration in blood exceeded 0.5 g/l, a level associated with fatal methanol poisoning. Ten putrefied cases were reanalyzed after 3-4 months storage, and no significant changes in FA concentrations were seen. These observations suggest that FA was formed by putrefaction during the post-mortem period, not during sample storage when sodium fluoride was added as a preservative. In methanol-positive cases, the mean (and median) FA concentrations were 0.80 g/l (0.88 g/l) and 3.4 g/l (3.3 g/l) in blood and urine, respectively, and the concentrations ranged from 0.19 to 1.0 g/l in blood and from 1.7 to 5.6 g/l in urine. The mean (and median) methanol concentrations in methanol-positive cases were 3.0 g/l (3.0 g/l) and 4.4 g/l (4.7 g/l) in blood and in urine, respectively. The highest methanol concentrations were 6.0 g/l and 8.7 g/l in blood and urine, respectively. No ethyl alcohol was found in the methanol-positive blood samples. Poor correlation was shown between blood and urine concentrations of FA. Poor correlations were also shown, in both blood and urine, between methanol and FA concentrations. PMID:21112705

  2. Rapid determination of 226Ra in emergency urine samples

    SciTech Connect

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B.; Utsey, Robin C.; McAlister, Daniel R.

    2014-02-27

    A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed. The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226Ra with DGA Resin, saving time. 133Ba was used instead of 225Ra as tracer to allow immediate counting; however, 225Ra can still be used as an option. The rapid purification of 226Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226Ra, with rapid removal of isobaric interferences.

  3. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples.

    PubMed

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients

  4. Diagnosis of neonatal group B Streptococcus sepsis by nested-PCR of residual urine samples

    PubMed Central

    Cezarino, Bruno Nicolino; Yamamoto, Lidia; Del Negro, Gilda Maria Barbaro; Rocha, Daisy; Okay, Thelma Suely

    2008-01-01

    Group B streptococcus (GBS) remains the most common cause of early-onset sepsis in newborns. Laboratory gold-standard, broth culture methods are highly specific, but lack sensitivity. The aim of this study was to validate a nested-PCR and to determine whether residue volumes of urine samples obtained by non invasive, non sterile methods could be used to confirm neonatal GBS sepsis. The nested-PCR was performed with primers of the major GBS surface antigen. Unavailability of biological samples to perform life supporting exams, as well as others to elucidate the etiology of infections is a frequent problem concerning newborn patients. Nevertheless, we decided to include cases according to strict criteria: newborns had to present with signs and symptoms compatible with GBS infection; at least one of the following biological samples had to be sent for culture: blood, urine, or cerebrospinal fluid; availability of residue volumes of the samples sent for cultures, or of others collected on the day of hospitalization, prior to antibiotic therapy prescription, to be analyzed by PCR; favorable outcome after GBS empiric treatment. In only one newborn GBS infection was confirmed by cultures, while infection was only presumptive in the other three patients (they fulfilled inclusion criteria but were GBS-culture negative). From a total of 12 biological samples (5 blood, 3 CSF and 4 urine specimen), eight were tested by culture methods (2/8 were positive), and 8 were tested by PCR (7/8 were positive), and only 4 samples were simultaneously tested by both methods (1 positive by culture and 3 by PCR). In conclusion, although based on a restricted number of neonates and samples, our results suggest that the proposed nested-PCR might be used to diagnose GBS sepsis as it has successfully amplified the three types of biological samples analyzed (blood, urine and cerebrospinal fluid), and was more sensitive than culture methods as PCR in urine confirmed diagnosis in all four patients

  5. Measurement of fallout {sup 239}Pu levels in urine samples by fission track analysis

    SciTech Connect

    Moorthy, A.R.; Doty, R.M.

    1996-11-01

    A Fission Track Analysis (FTA) method for assessing 239Pu in urine samples was first developed at Brookhaven National Laboratory (BNL) in 1988; it then had a detection limit of 100 aCi (3.7 {micro}Bq). Since that time, several steps were introduced that increased chemical recovery and lowered the detection limit to less than 1O aCi per sample. These improvements include a process of micro-column separation of plutonium in the final stages. The improved FTA method was applied to 22 urine samples from male staff at BNL. The results showed that 239Pu from fallout excreted in urine was 33 +/- 11 aCi (1.2 {micro}Bq) per day.

  6. A 24 Hr Global Campaign to Assess Precision Timing of the Millisecond Pulsar J1713+0747

    NASA Astrophysics Data System (ADS)

    Dolch, T.; Lam, M. T.; Cordes, J.; Chatterjee, S.; Bassa, C.; Bhattacharyya, B.; Champion, D. J.; Cognard, I.; Crowter, K.; Demorest, P. B.; Hessels, J. W. T.; Janssen, G.; Jenet, F. A.; Jones, G.; Jordan, C.; Karuppusamy, R.; Keith, M.; Kondratiev, V.; Kramer, M.; Lazarus, P.; Lazio, T. J. W.; Lee, K. J.; McLaughlin, M. A.; Roy, J.; Shannon, R. M.; Stairs, I.; Stovall, K.; Verbiest, J. P. W.; Madison, D. R.; Palliyaguru, N.; Perrodin, D.; Ransom, S.; Stappers, B.; Zhu, W. W.; Dai, S.; Desvignes, G.; Guillemot, L.; Liu, K.; Lyne, A.; Perera, B. B. P.; Petroff, E.; Rankin, J. M.; Smits, R.

    2014-10-01

    The radio millisecond pulsar J1713+0747 is regarded as one of the highest-precision clocks in the sky and is regularly timed for the purpose of detecting gravitational waves. The International Pulsar Timing Array Collaboration undertook a 24 hr global observation of PSR J1713+0747 in an effort to better quantify sources of timing noise in this pulsar, particularly on intermediate (1-24 hr) timescales. We observed the pulsar continuously over 24 hr with the Arecibo, Effelsberg, GMRT, Green Bank, LOFAR, Lovell, Nançay, Parkes, and WSRT radio telescopes. The combined pulse times-of-arrival presented here provide an estimate of what sources of timing noise, excluding DM variations, would be present as compared to an idealized \\sqrt{N} improvement in timing precision, where N is the number of pulses analyzed. In the case of this particular pulsar, we find that intrinsic pulse phase jitter dominates arrival time precision when the signal-to-noise ratio of single pulses exceeds unity, as measured using the eight telescopes that observed at L band/1.4 GHz. We present first results of specific phenomena probed on the unusually long timescale (for a single continuous observing session) of tens of hours, in particular interstellar scintillation, and discuss the degree to which scintillation and profile evolution affect precision timing. This paper presents the data set as a basis for future, deeper studies.

  7. A 24 hr global campaign to assess precision timing of the millisecond pulsar J1713+0747

    SciTech Connect

    Dolch, T.; Lam, M. T.; Cordes, J.; Chatterjee, S.; Bassa, C.; Hessels, J. W. T.; Janssen, G.; Kondratiev, V.; Bhattacharyya, B.; Jordan, C.; Keith, M.; Champion, D. J.; Karuppusamy, R.; Kramer, M.; Lazarus, P.; Cognard, I.; Demorest, P. B.; Jenet, F. A.; Jones, G.; and others

    2014-10-10

    The radio millisecond pulsar J1713+0747 is regarded as one of the highest-precision clocks in the sky and is regularly timed for the purpose of detecting gravitational waves. The International Pulsar Timing Array Collaboration undertook a 24 hr global observation of PSR J1713+0747 in an effort to better quantify sources of timing noise in this pulsar, particularly on intermediate (1-24 hr) timescales. We observed the pulsar continuously over 24 hr with the Arecibo, Effelsberg, GMRT, Green Bank, LOFAR, Lovell, Nançay, Parkes, and WSRT radio telescopes. The combined pulse times-of-arrival presented here provide an estimate of what sources of timing noise, excluding DM variations, would be present as compared to an idealized √N improvement in timing precision, where N is the number of pulses analyzed. In the case of this particular pulsar, we find that intrinsic pulse phase jitter dominates arrival time precision when the signal-to-noise ratio of single pulses exceeds unity, as measured using the eight telescopes that observed at L band/1.4 GHz. We present first results of specific phenomena probed on the unusually long timescale (for a single continuous observing session) of tens of hours, in particular interstellar scintillation, and discuss the degree to which scintillation and profile evolution affect precision timing. This paper presents the data set as a basis for future, deeper studies.

  8. Rapid detection of E. coli cells in urine samples using a self-capacitance touchscreen device.

    PubMed

    Bergstrom, Jennifer Panugan; Tao Dong

    2015-08-01

    Escherichia coli is one of the main causes of urinary tract infections (UTIs). E. coli is commonly detected from urine using standard culture method. However, the urine sampling and analysis required for these methods can be costly, time consuming (requires 24 to 48 hours) and labor-intensive. This work proposes a capacitive touch screen sensor concept as possible alternative device for rapid detection of E. coli in urine samples. E. coli solutions prepared at different concentrations and urine samples (with spiked and nor spike E. coli) obtained from healthy women participants, have been analyzed using a capacitance evaluation kit. It has been demonstrated in this study that the use of this evaluation kit provides a low-cost and simple alternative system for detecting E. coli present in urine. Several experimental tests were performed to determine the optimal testing volume, the sensitivity of the sensor, limit of detection and repeatability. The optimal testing volume was 80 microliters and the analytical sensitivity was 17 counts per picofarad (pF). The lowest detectable concentration is around 3.98 × 10(5) CFU/ml. The repeatability (r) was found to be 7.2 or 6.2 % (in r%). The capacitive touch sensor gave promising results that could be used to design and realize a portable diagnostic device for early-stage detection of UTIs. PMID:26737548

  9. Raman spectroscopy-based creatinine measurement in urine samples from a multipatient population.

    PubMed

    McMurdy, John W; Berger, Andrew J

    2003-05-01

    Spectroscopic methods of urinalysis offer several advantages over chemical methods, including less sample contact and higher information content. In particular, urine creatinine has been the subject of several spectroscopic studies. We report the first use of Raman spectroscopy to measure creatinine concentrations in unaltered urine samples from a multipatient population. Using near-infrared excitation and a hybrid linear analysis calibration method, a root mean squared error of cross-validation (RMSECV) of 4.9 mg/dL was obtained. The error in the reference chemical method was 1.1 mg/dL. This result shows that the Raman spectroscopy can measure creatinine at clinical levels even in the presence of patient-to-patient variations. Because most assays in urine require creatinine concentration in order to correct for fluctuations in water content, measurement of creatinine is the first step towards more extensive Raman-based urinalysis. PMID:14658677

  10. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  11. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  12. Mutagens in urine sampled repetitively from municipal refuse incinerator workers and water treatment workers

    SciTech Connect

    Ma, Xin Fang; Babish, J.G.; Scarlett, J.M.; Gutenmann, W.H.; Lisk, D.J. )

    1992-12-01

    Municipal refuse incinerator workers may be exposed to mutagenic compounds from combustion gases and particulates during plant operation, maintenance, and ash removal procedures. The frequency of mutagens was measured by the Ames assay in 3 urine samples collected from each of 37 workers in 4 refuse incinerators and 35 (control) workers from 8 water treatment plants during June-August 1990. When comparing the first urine samples contributed by workers in each cohort, incinerator workers had a significantly (p < .05) increased risk of both direct-acting mutagens and promutagens (8/37 or 22% for each mutagen type) compared with water treatment workers (2/35 or 6% for each mutagen type). Smoking within 24 h before urine sampling was not a confounder of these results. Interestingly, there was no significant (p > .05) difference for risk of urinary mutagens or promutagens between the two cohorts when comparing, respectively, the second and third urine samples from each cohort. The repeatability of demonstrating urinary mutagens in individual incinerator workers was poor, suggesting that their exposure was highly variable and/or that these workers modified their exposure (e.g., wore masks) as a consequence of being studied. Factors that influence production of mutagenic compounds during refuse incineration and subsequent worker exposure are discussed.

  13. Evaluation of the results of Mycobacterium tuberculosis direct test (MTD) and Mycobacterial culture in urine samples

    PubMed Central

    Sener, Asli Gamze; Kurultay, Nukhet; Afsar, Ilhan

    2008-01-01

    Tuberculosis remains a public health problem in Turkey. Rapid detection of Mycobacterium tuberculosis plays a key role in control of infection. In this article, the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD) was evaluated for detection of M. tuberculosis in urine samples. The performance of the MTD was very good and appropriate for routine laboratory diagnosis. PMID:24031287

  14. Determination of (210)Po in drinking water and urine samples using copper sulfide microprecipitation.

    PubMed

    Guérin, Nicolas; Dai, Xiongxin

    2014-06-17

    Polonium-210 ((210)Po) can be rapidly determined in drinking water and urine samples by alpha spectrometry using copper sulfide (CuS) microprecipitation. For drinking water, Po in 10 mL samples was directly coprecipitated onto the filter for alpha counting without any purification. For urine, 10 mL of sample was heated, oxidized with KBrO3 for a short time (∼5 min), and subsequently centrifuged to remove the suspended organic matter. The CuS microprecipitation was then applied to the supernatant. Large batches of samples can be prepared using this technique with high recoveries (∼85%). The figures of merit of the methods were determined, and the developed methods fulfill the requirements for emergency and routine radioassays. The efficiency and reliability of the procedures were confirmed using spiked samples. PMID:24906041

  15. [Estimation of quantitative proteinuria using a new dipstick in random urine samples].

    PubMed

    Morishita, Yoshiyuki; Kusano, Eiji; Umino, Tetsuo; Nemoto, Jun; Tanba, Kaichirou; Ando, Yasuhiro; Muto, Shigeaki; Asano, Yasushi

    2004-02-01

    Proteinuria is quantified for diagnostic and prognostic purposes and to assess responses to therapy. Methods used to assess urinary protein include 24-hour urine collection (24-Up) and determination of the ratio of protein to creatinine concentration (Up/Ucr) in simple voided urine samples (Up/Ucr quantitative method). However, these methods are costly and time consuming. The Multistix PRO 11 (Bayer Medical Co., Ltd., Tokyo, Japan) is a new urine dipstick that allows rapid measurement of Up/Ucr. Results obtained with the Multistix PRO 11 coincided well with those obtained with the 24-Up method (kappa = 0.68) and the Up/Ucr quantitative method (kappa = 0.75). However, Multistix PRO 11 did not accurately measure moderate to severe proteinuria (> or = 500 mg/g. Cr). Our findings suggest that Multistix PRO 11 is useful for the screening, assessment, and follow-up of mild proteinuria. PMID:15058105

  16. Forensic identification of urine samples: a comparison between nuclear and mitochondrial DNA markers.

    PubMed

    Castella, V; Dimo-Simonin, N; Brandt-Casadevall, C; Robinson, N; Saugy, M; Taroni, F; Mangin, P

    2006-03-01

    Urine samples from 20 male volunteers of European Caucasian origin were stored at 4 degrees C over a 4-month period in order to compare the identification potential of nuclear DNA (nDNA) and mitochondrial DNA (mtDNA) markers. The amount of nDNA recovered from urines dramatically declined over time. Consequently, nDNA likelihood ratios (LRs) greater than 1,000 were obtained for 100, 70 and 55% of the urines analysed after 6, 60 and 120 days, respectively. For the mtDNA, HVI and HVII sequences were obtained for all samples tested, whatever the period considered. Nevertheless, the highest mtDNA LR of 435 was relatively low compared to its nDNA equivalent. Indeed, LRs obtained with only three nDNA loci could easily exceed this value and are quite easier to obtain. Overall, the joint use of nDNA and mtDNA markers enabled the 20 urine samples to be identified, even after the 4-month period. PMID:16133560

  17. Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples

    PubMed Central

    Lozano-Ramos, Inés; Bancu, Ioana; Oliveira-Tercero, Anna; Armengol, María Pilar; Menezes-Neto, Armando; Del Portillo, Hernando A.; Lauzurica-Valdemoros, Ricardo; Borràs, Francesc E.

    2015-01-01

    Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage. Urine is an easily accessible fluid and urinary extracellular vesicles (EVs) may be ideal to describe new biomarkers associated with renal pathologies. Several methods to enrich EVs have been described. Most of them contain a mixture of proteins, lipoproteins and cell debris that may be masking relevant biomarkers. Here, we evaluated size-exclusion chromatography (SEC) as a suitable method to isolate urinary EVs. Following a conventional centrifugation to eliminate cell debris and apoptotic bodies, urine samples were concentrated using ultrafiltration and loaded on a SEC column. Collected fractions were analysed by protein content and flow cytometry to determine the presence of tetraspanin markers (CD63 and CD9). The highest tetraspanin content was routinely detected in fractions well before the bulk of proteins eluted. These tetraspanin-peak fractions were analysed by cryo-electron microscopy (cryo-EM) and nanoparticle tracking analysis revealing the presence of EVs. When analysed by sodium dodecyl sulphate–polyacrylamide gel electrophoresis, tetraspanin-peak fractions from urine concentrated samples contained multiple bands but the main urine proteins (such as Tamm–Horsfall protein) were absent. Furthermore, a preliminary proteomic study of these fractions revealed the presence of EV-related proteins, suggesting their enrichment in concentrated samples. In addition, RNA profiling also showed the presence of vesicular small RNA species. To summarize, our results demonstrated that concentrated urine followed by SEC is a suitable option to isolate EVs with low presence of soluble contaminants. This methodology could permit more accurate analyses of EV-related biomarkers when further characterized by -omics technologies compared with other approaches. PMID:26025625

  18. Generic immunoassay of corticosteroids with minimum pre-treatment of urine samples.

    PubMed

    Rodriguez, M L; McConnell, I; Lamont, J; Campbell, J; FitzGerald, S P

    1994-12-01

    A generic, rapid and sensitive enzyme linked immunosorbent assay (ELISA) test has been developed which allows large-scale simultaneous testing of synthetic corticosteroids viz., flumethasone, dexamethasone and betamethasone. This assay can be directly applied to diluted urine samples (1 + 9) without hydrolysis of glucuronide or sulfate conjugates or any other treatment of samples. The polyclonal antibody was obtained by immunizing sheep with a flumethasone derivative linked to human serum albumin. This polyclonal antibody displayed high-reactivity with several synthetic corticosteroids whilst endogenous corticosteroids such as cortisol gave very low cross-reactivity (< 0.5%). Sensitivities obtained in this assay were 2.5, 3.1 and 12.5 ng ml-1 for flumethasone, dexamethasone and betamethasone, respectively. The ability of this assay to detect several synthetic corticosteroids was demonstrated by testing urine samples from horses to which the drugs had been administered. PMID:7879866

  19. Reproducibility of NMR Analysis of Urine Samples: Impact of Sample Preparation, Storage Conditions, and Animal Health Status

    PubMed Central

    Schreier, Christina; Kremer, Werner; Huber, Fritz; Neumann, Sindy; Pagel, Philipp; Lienemann, Kai; Pestel, Sabine

    2013-01-01

    Introduction. Spectroscopic analysis of urine samples from laboratory animals can be used to predict the efficacy and side effects of drugs. This employs methods combining 1H NMR spectroscopy with quantification of biomarkers or with multivariate data analysis. The most critical steps in data evaluation are analytical reproducibility of NMR data (collection, storage, and processing) and the health status of the animals, which may influence urine pH and osmolarity. Methods. We treated rats with a solvent, a diuretic, or a nephrotoxicant and collected urine samples. Samples were titrated to pH 3 to 9, or salt concentrations increased up to 20-fold. The effects of storage conditions and freeze-thaw cycles were monitored. Selected metabolites and multivariate data analysis were evaluated after 1H NMR spectroscopy. Results. We showed that variation of pH from 3 to 9 and increases in osmolarity up to 6-fold had no effect on the quantification of the metabolites or on multivariate data analysis. Storage led to changes after 14 days at 4°C or after 12 months at −20°C, independent of sample composition. Multiple freeze-thaw cycles did not affect data analysis. Conclusion. Reproducibility of NMR measurements is not dependent on sample composition under physiological or pathological conditions. PMID:23865070

  20. Optimization of a pre-MEKC separation SPE procedure for steroid molecules in human urine samples.

    PubMed

    Olędzka, Ilona; Kowalski, Piotr; Dziomba, Szymon; Szmudanowski, Piotr; Bączek, Tomasz

    2013-01-01

    Many steroid hormones can be considered as potential biomarkers and their determination in body fluids can create opportunities for the rapid diagnosis of many diseases and disorders of the human body. Most existing methods for the determination of steroids are usually time- and labor-consuming and quite costly. Therefore, the aim of analytical laboratories is to develop a new, relatively low-cost and rapid implementation methodology for their determination in biological samples. Due to the fact that there is little literature data on concentrations of steroid hormones in urine samples, we have made attempts at the electrophoretic determination of these compounds. For this purpose, an extraction procedure for the optimized separation and simultaneous determination of seven steroid hormones in urine samples has been investigated. The isolation of analytes from biological samples was performed by liquid-liquid extraction (LLE) with dichloromethane and compared to solid phase extraction (SPE) with C18 and hydrophilic-lipophilic balance (HLB) columns. To separate all the analytes a micellar electrokinetic capillary chromatography (MECK) technique was employed. For full separation of all the analytes a running buffer (pH 9.2), composed of 10 mM sodium tetraborate decahydrate (borax), 50 mM sodium dodecyl sulfate (SDS), and 10% methanol was selected. The methodology developed in this work for the determination of steroid hormones meets all the requirements of analytical methods. The applicability of the method has been confirmed for the analysis of urine samples collected from volunteers--both men and women (students, amateur bodybuilders, using and not applying steroid doping). The data obtained during this work can be successfully used for further research on the determination of steroid hormones in urine samples. PMID:24232737

  1. Assessment of human exposure to atrazine through the determination of free atrazine in urine

    SciTech Connect

    Catenacci, G. ); Maroni, M. ); Cottica, D. ); Pozzoli, L.

    1990-01-01

    Studies on metabolism and excretion of atrazine in man are not available in the literature. The present study has investigated human exposure to atrazine during its industrial production by means of assessment of ambient exposure and determination of free atrazine in urine. Four workers exposed to atrazine during its manufacture and packaging in a production plant, volunteered for the study. Atrazine was determined in airborne dust of the working environment obtained by personal sampling, on skin pads according to the WHO standard method, and on the skin of the hands of the workers by means of a washing procedure. Urine was collected before, during, and after exposure. A 24 hr collection before the first workshift, all the urine voided during the monitoring period, subdivided in 8 hr fractions; and one or more 12 hr samples after the end of the exposure period were collected.

  2. Direct Identification of Urinary Tract Pathogens from Urine Samples, Combining Urine Screening Methods and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    PubMed

    Íñigo, Melania; Coello, Andreu; Fernández-Rivas, Gema; Rivaya, Belén; Hidalgo, Jessica; Quesada, María Dolores; Ausina, Vicente

    2016-04-01

    Early diagnosis of urinary tract infections (UTIs) is essential to avoid inadequate or unnecessary empirical antibiotic therapy. Microbiological confirmation takes 24 to 48 h. The use of screening methods, such as cytometry and automated microscopic analysis of urine sediment, allows the rapid prediction of negative samples. In addition, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is a widely established technique in clinical microbiology laboratories used to identify microorganisms. We evaluated the ability of MALDI-TOF MS to identify microorganisms from direct urine samples and the predictive value of automated analyzers for the identification of microorganisms in urine by MALDI-TOF MS. A total of 451 urine samples from patients with suspected UTIs were first analyzed using the Sysmex UF-1000iflow cytometer, an automatic sediment analyzer with microscopy (SediMax), culture, and then processed by MALDI-TOF MS with a simple triple-centrifuged procedure to obtain a pellet that was washed and centrifuged and finally applied directly to the MALDI-TOF MS plate. The organisms in 336 samples were correctly identified, mainly those with Gram-negative bacteria (86.10%). No microorganisms were misidentified, and noCandidaspp. were correctly identified. Regarding the data from autoanalyzers, the best bacteriuria cutoffs were 1,000 and 200 U/μl for UF-1000iand SediMax, respectively. It was concluded that the combination of a urine screening method and MALDI-TOF MS provided a reliable identification from urine samples, especially in those containing Gram-negative bacteria. PMID:26818668

  3. Molecularly Imprinted Composite Membranes for Selective Detection of 2-Deoxyadenosine in Urine Samples

    PubMed Central

    Scorrano, Sonia; Mergola, Lucia; Di Bello, Maria Pia; Lazzoi, Maria Rosaria; Vasapollo, Giuseppe; Del Sole, Roberta

    2015-01-01

    An important challenge for scientific research is the production of artificial systems able to mimic the recognition mechanisms occurring at the molecular level in living systems. A valid contribution in this direction resulted from the development of molecular imprinting. In this work, a novel molecularly imprinted polymer composite membrane (MIM) was synthesized and employed for the selective detection in urine samples of 2-deoxyadenosine (2-dA), an important tumoral marker. By thermal polymerization, the 2-dA-MIM was cross-linked on the surface of a polyvinylidene-difluoride (PVDF) membrane. By characterization techniques, the linking of the imprinted polymer on the surface of the membrane was found. Batch-wise guest binding experiments confirmed the absorption capacity of the synthesized membrane towards the template molecule. Subsequently, a time-course of 2-dA retention on membrane was performed and the best minimum time (30 min) to bind the molecule was established. HPLC analysis was also performed to carry out a rapid detection of target molecule in urine sample with a recovery capacity of 85%. The experiments indicated that the MIM was highly selective and can be used for revealing the presence of 2-dA in urine samples. PMID:26086824

  4. Quantitative determinations of levofloxacin and rifampicin in pharmaceutical and urine samples using nuclear magnetic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Salem, A. A.; Mossa, H. A.; Barsoum, B. N.

    2005-11-01

    Rapid, specific and simple methods for determining levofloxacin and rifampicin antibiotic drugs in pharmaceutical and human urine samples were developed. The methods are based on 1H NMR spectroscopy using maleic acid as an internal standard and DMSO-d6 as NMR solvent. Integration of NMR signals at 8.9 and 8.2 ppm were, respectively, used for calculating the concentration of levofloxacin and rifampicin drugs per unit dose. Maleic acid signal at 6.2 ppm was used as the reference signal. Recoveries of (97.0-99.4) ± 0.5 and (98.3-99.7) ± 1.08% were obtained for pure levofloxacin and rifampicin, respectively. Corresponding recoveries of 98.5-100.3 and 96.8-100.0 were, respectively, obtained in pharmaceutical capsules and urine samples. Relative standard deviations (R.S.D.) values ≤2.7 were obtained for analyzed drugs in pure, pharmaceutical and urine samples. Statistical Student's t-test gave t-values ≤2.87 indicating insignificant difference between the real and the experimental values at the 95% confidence level. F-test revealed insignificant difference in precisions between the developed NMR methods and each of fluorimetric and HPLC methods for analyzing levofloxacin and rifampicin.

  5. Variability of Urinary Concentrations of Bisphenol A in Spot Samples, First Morning Voids, and 24-Hour Collections

    PubMed Central

    Wong, Lee-Yang; Bishop, Amber M.; Calafat, Antonia M.

    2011-01-01

    Background: Human exposure to bisphenol A (BPA) is widespread. After exposure, BPA is rapidly metabolized and eliminated in urine. Therefore, there is considerable within-person and between-person variability of BPA concentrations in spot urine samples. However, no information exists on the within-day variability of urinary BPA concentrations. Objectives: We examined the between-person and within-person and between-day and within-day variability in the urinary BPA concentrations of eight adults who collected all voids for 1 week to investigate the impact of sampling strategy in the exposure assessment of BPA using spot, first morning, or 24-hr urine collections. Methods: We determined the urinary concentrations of BPA using on-line solid-phase extraction coupled to isotope dilution high-performance liquid chromatography/tandem mass spectrometry. Results: The between-day and within-person variability was the primary contributor to the total variance both for first morning voids (77%) and 24-hr urine collections (88%). For the spot collections, we observed considerable within-day variance (70%), which outweighed the between-person (9%) and between-day and within-person (21%) variances. Conclusions: Regardless of the type of void (spot, first morning, 24-hr collection), urinary BPA concentrations for a given adult changed considerably—both within a day and for the 7 days of the study period. Single 24-hr urine collections accurately reflect daily exposure but can misrepresent variability in daily exposures over time. Of interest, when the population investigated is sufficiently large and samples are randomly collected relative to meal ingestion times and bladder emptying times, the single spot–sampling approach may adequately reflect the average exposure of the population to BPA. PMID:21406337

  6. [Isolated yeast species in urine samples in a Spanish regional hospital].

    PubMed

    Heras-Cañas, Victor; Ros, Luis; Sorlózano, Antonio; Gutiérrez-Soto, Blanca; Navarro-Marí, José María; Gutiérrez-Fernández, José

    2015-01-01

    Candiduria detection in hospitalized or immunocompromised patients is of great clinical significance. The aim of our study was to describe the isolation frequency of significant species of yeasts in urine samples processed in our hospital during the period 2010- 2013, and to analyze their susceptibility to commonly used antifungal agents. Species identification was performed by seeding on a chromogenic medium, the filamentation test and automated systems (ASM Vitek and MALDI Biotyper), while susceptibility was determined using the ASM Vitek system. Of the 632 yeast isolates in urine, 371 were Candida albicans species and 261 non-C. albicans Candida spp. The species with the highest number of resistant isolates were Candida glabrata and Candida krusei. Based on the results obtained, we believe that species identification and the susceptibility study should be current practice in the laboratories when species other than C. albicans are isolated. PMID:26507634

  7. Rapid, culture-independent, optical diagnostics of centrifugally captured bacteria from urine samples

    PubMed Central

    Schröder, Ulrich-Christian; Bokeloh, Frank; O'Sullivan, Mary; Glaser, Uwe; Wolf, Katharina; Pfister, Wolfgang; Popp, Jürgen; Ducrée, Jens; Neugebauer, Ute

    2015-01-01

    This work presents a polymeric centrifugal microfluidic platform for the rapid and sensitive identification of bacteria directly from urine, thus eliminating time-consuming cultivation steps. This “Lab-on-a-Disc” platform utilizes the rotationally induced centrifugal field to efficiently capture bacteria directly from suspension within a glass-polymer hybrid chip. Once trapped in an array of small V-shaped structures, the bacteria are readily available for spectroscopic characterization, such as Raman spectroscopic fingerprinting, providing valuable information on the characteristics of the captured bacteria. Utilising fluorescence microscopy, quantification of the bacterial load has been achieved for concentrations above 2 × 10−7 cells ml−1 within a 4 μl sample. As a pilot application, we characterize urine samples from patients with urinary tract infections. Following minimal sample preparation, Raman spectra of the bacteria are recorded following centrifugal capture in stopped-flow sedimentation mode. Utilizing advanced analysis algorithms, including extended multiplicative scattering correction, high-quality Raman spectra of different pathogens, such as Escherichia coli or Enterococcus faecalis, are obtained from the analyzed patient samples. The whole procedure, including sample preparation, requires about 1 h to obtain a valuable result, marking a significant reduction in diagnosis time when compared to the 24 h and more typically required for standard microbiological methods. As this cost-efficient centrifugal cartridge can be operated using low-complexity, widely automated instrumentation, while providing valuable bacterial identification in urine samples in a greatly reduced time-period, our opto-microfluidic Lab-on-a-Disc device demonstrates great potential for next-generation patient diagnostics at the of point-of-care. PMID:26339318

  8. Comparison between Urine and Cervical Samples for HPV DNA Detection and Typing in Young Women in Colombia.

    PubMed

    Cómbita, Alba Lucía; Gheit, Tarik; González, Paula; Puerto, Devi; Murillo, Raúl Hernando; Montoya, Luisa; Vorsters, Alex; Van Keer, Severien; Van Damme, Pierre; Tommasino, Massimo; Hernández-Suárez, Gustavo; Sánchez, Laura; Herrero, Rolando; Wiesner, Carolina

    2016-09-01

    Urine sampling for HPV DNA detection has been proposed as an effective method for monitoring the impact of HPV vaccination programs; however, conflicting results have been reported. The goal of this study was to evaluate the performance of optimized urine HPV DNA testing in women aged 19 to 25 years. Optimization process included the use of first void urine, immediate mixing of urine with DNA preservative, and the concentration of all HPV DNA, including cell-free DNA fragments. Urine and cervical samples were collected from 535 young women attending cervical screening at health centers from two Colombian cities. HPV DNA detection and genotyping was performed using an HPV type-specific multiplex genotyping assay, which combines multiplex polymerase chain reaction with bead-based Luminex technology. Concordance between HPV DNA detection in urine and cervical samples was determined using kappa statistics and McNemar tests. The accuracy of HPV DNA testing in urine samples was evaluated measuring sensitivity and specificity using as reference the results obtained from cervical samples. Statistical analysis was performed using STATA11.2 software. The findings revealed an overall HPV prevalence of 60.00% in cervical samples and 64.72% in urine samples, HPV-16 being the most frequent HPV type detected in both specimens. Moreover, our results indicate that detection of HPV DNA in first void urine provides similar results to those obtained with cervical samples and can be used to monitor HPV vaccination trials and programs as evidenced by the substantial concordance found for the detection of the four vaccine types. Cancer Prev Res; 9(9); 766-71. ©2016 AACR. PMID:27417431

  9. Analysis of a Ricin Biomarker, Ricinine, in 989 Individual Human Urine Samples

    PubMed Central

    Pittman, Christopher T.; Guido, John; Hamelin, Elizabeth I.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    Ricinine (3-cyano-4-methoxy-N-methyl-2-pyridone) is a urinary biomarker which can be measured to confirm human exposure to castor bean products such as ricin. As many consumer products contain castor oil, another castor bean product, ricinine may be detectable in the general population. The following study characterized urinary ricinine concentrations from 989 individuals who were presumed to be unexposed to ricin. An automated diagnostic method was utilized here to simplify the analysis of this large sample set. Sample preparation included a 96-well polystyrene divinylbenzene high throughput extraction and preconcentration step. Purified samples were analyzed by an efficient dual column, reversed phase liquid chromatography separation and 13C-isotope dilution tandem mass spectrometry. In this convenience sample, only 1.2% of the urine samples had detectable amounts of ricinine randomly distributed between 0.186 and 4.15 ng/mL. PMID:23471955

  10. Black market products confiscated in Norway 2011-2014 compared to analytical findings in urine samples.

    PubMed

    Hullstein, Ingunn R; Malerod-Fjeld, Helle; Dehnes, Yvette; Hemmersbach, Peter

    2015-01-01

    Doping agents are widely and illicitly distributed through the Internet. Analysis of these preparations is useful in order to monitor the availability of prohibited substances on the market, and more importantly to predict which substances are expected to be found in urine samples collected from athletes and to aid clinical and forensic investigations. Based on a close collaboration with the Norwegian police and the Norwegian custom authorities, the Norwegian Doping Control Laboratory has performed analyses of confiscated material suspected of containing doping agents. The analyses were performed using gas chromatography (GC) and liquid chromatography (LC) combined with mass spectrometry (MS). The majority (67%) of the analyzed black market products contained anabolic- androgenic steroids (AAS) as expected, whereas peptide- and protein-based doping substances were identified in 28% of the preparations. The Norwegian Doping Control Laboratory receives samples collected from recreational and elite athletes in addition to samples collected in clinical and forensic investigations. The findings in the seized material reflected the findings in the urine samples analyzed regarding the anabolic steroids. Thus, analyzing material seized in Norway may give a good indication of doping agents available on the local market. PMID:26607218

  11. Loop Mediated Isothermal Amplification for Detection of Trypanosoma brucei gambiense in Urine and Saliva Samples in Nonhuman Primate Model

    PubMed Central

    Ngotho, Maina; Kagira, John Maina; Gachie, Beatrice Muthoni; Karanja, Simon Muturi; Waema, Maxwell Wambua; Maranga, Dawn Nyawira; Maina, Naomi Wangari

    2015-01-01

    Human African trypanosomiasis (HAT) is a vector-borne parasitic zoonotic disease. The disease caused by Trypanosoma brucei gambiense is the most prevalent in Africa. Early diagnosis is hampered by lack of sensitive diagnostic techniques. This study explored the potential of loop mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR) in the detection of T. b. gambiense infection in a vervet monkey HAT model. Six vervet monkeys were experimentally infected with T. b. gambiense IL3253 and monitored for 180 days after infection. Parasitaemia was scored daily. Blood, cerebrospinal fluid (CSF), saliva, and urine samples were collected weekly. PCR and LAMP were performed on serum, CSF, saliva, and urine samples. The detection by LAMP was significantly higher than that of parasitological methods and PCR in all the samples. The performance of LAMP varied between the samples and was better in serum followed by saliva and then urine samples. In the saliva samples, LAMP had 100% detection between 21 and 77 dpi, whereas in urine the detection it was slightly lower, but there was over 80% detection between 28 and 91 dpi. However, LAMP could not detect trypanosomes in either saliva or urine after 140 and 126 dpi, respectively. The findings of this study emphasize the importance of LAMP in diagnosis of HAT using saliva and urine samples. PMID:26504841

  12. [Environmental tobacco smoke--assessment of formaldehyde concentration in urine samples of exposed medicine students].

    PubMed

    Szumska, Magdalena; Damasiewicz-Bodzek, Aleksandra; Tyrpień-Golder, Krystyna

    2015-01-01

    Environmental Tobacco Smoke (ETS) is ranked as one of the factors of confirmed carcinogenicity to human. It consists of the mixture of smoke exhaled by the smoker as well as the sidestream smoke and contains many times higher concentrations of some toxic substances in comparison to the amount of toxic compounds inhaled by a smoker. From many years the issue of passive smoking has been the subject of many research and still not all of its aspects of affecting human health have been explored. Apart from the tobacco varieties, also diverse additives added during the process of tobacco manufacturing, including particularly carbohydrates, influence the composition of the environmental tobacco smoke. During smoking they can undergo many complex transformations, as a result of which toxic components of the environmental tobacco smoke are formed, carbonyl compounds in particular, like aldehydes. They are marked by a significant chemical reactivity which enables them to modify amino groups of proteins leading to the changes in their structure, biological functions and often antigenicity. Therefore their influence to the human body is the cause of numerous adverse health effects caused by the increase in free radical processes which can constitute to the source of these compounds. Well known representative of this group of xenobiotics is formaldehyde as a compound that reflects well the environmental exposure to carbonyl compounds. The considerable source of this compound is tobacco smoke. Therefore analysis of formaldehyde in body fluids is a valuable biomonitoring tool of exposure to it. The aim of this study was the evaluation of formaldehyde concentration in urine samples of medicine students exposed to ETS. The study material consisted of 149 urine samples of students from School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia. The concentration of formaldehyde in urine samples was determined by a spectrophotometric method using the

  13. Concept of a point of care test to detect new oral anticoagulants in urine samples

    PubMed Central

    2013-01-01

    New oral anticoagulants (NOAC) are approved for several indications for prophylaxis and treatment of venous thromboembolism and for prevention of embolism in atrial fibrillation at fixed daily doses without need of laboratory guided dose adjustment. Due to their low molecular weight of about 500 to 600 Dalton and their hydrophilicity free anticoagulant is excreted immediately through glomerular filtration into the urine. Impairment of renal function may increase the plasma concentration of the anticoagulants and lowered creatinine clearance is a declared contraindication. In contrast to the initial aim of development the anticoagulant effect is required to be determined in special clinical situations. Several specific and non-specific assays using plasma samples are currently undergoing standardization. As all NOACs are excreted into the urine, specific assays were developed for this matrix to determine them quantitatively of qualitatively. Urine samples can be easily and repetitively obtained avoiding problems and risks associated with blood sampling. The qualitative assay can be performed as a point of care test (POC) also by the patient by judging the different colours for the absence or presence of the drugs with the naked eye. The test is rapid (results available within 15 min), sensitive, specific and accurate and does not require a purified NOAC as control. The tests may be a tool for clinicians who need to know for treatment decisions if a NOAC is on board or not. As the tests are specific for oral direct thrombin inhibitors and for oral direct factor Xa inhibitors, the indication does not interfere with other qualitative POC test in development using clotting systems. The test may be indicated for patients at acute hospitalization, before surgery or central nervous system puncture anaesthesia, if fibrinolytic therapy is indicated, acute deterioration of renal function, and for control of adherence to therapy. PMID:23915217

  14. Fiber optic evaporation analysis of environmental parameters and of synthetic urine samples

    NASA Astrophysics Data System (ADS)

    Preter, Eyal; Katzman, Moshe; Oren, Ziv; Ronen, Maria; Gerber, Doron; Zadok, Avi

    2015-09-01

    The evaporation rate of water droplets is evaluated as a function of temperature and relative humidity using a fiber-optic sensor. Either parameter may be monitored when the other is known, with uncertainties of 0.5 deg. C or 1.5% relative humidity. Further, the sensor is used in the analysis of negative control synthetic solutions, made to mimic human urine. Samples of binary mixtures of the solution with water at different volume ratios are categorized using correlation analysis of the recorded evaporation dynamics, with 87% success. The results represent an important first step towards potential use of the sensor in point-of-care diagnostics.

  15. Colorimetric assay of noramidopyrine methanesulfonate sodium in formulations and in blood and urine samples.

    PubMed

    Diab, A H

    1977-04-01

    A simple, rapid, specific and sensitive colorimetric method is proposed for the quantitative estimation of noramido-pyrine methanesulfonate sodium in different dosage forms as well as in blood and urine samples. The method is based on the reaction of 3-sulfonic-5-amino-alpha-naphthol with formaldehyde liberated from noramidopyrine methanesulfonate sodium after treatment with conc. sulfuric acid where a yellow colour appeared immediately which turned to blue on dilution with water. The blue colour obeyed Beer's law (10--400 microgram) and remained stable for more than 1 h. The effect of other drugs, tablet excipients, parentral vehicles and suppository bases was studied. PMID:896911

  16. Solid-phase dispersive extraction method for analysis of benzodiazepine drugs in serum and urine samples.

    PubMed

    Saito, Koichi; Kikuchi, Yuu; Saito, Rieko

    2014-11-01

    A simple yet highly efficient pretreatment method called solid-phase dispersive extraction (SPDE) was developed and used in combination with liquid chromatography/time-of-flight mass spectrometry (LC/TOF-MS) for the analysis of benzodiazepines (BZPs) in serum and urine samples. By using a custom-made centrifugal filter, SPDE could be performed in a closed system, thereby minimizing exposure to infectious microbes or hazardous chemicals. The limit of detection and the limit of quantification of nine BZPs were 1-10 and 5-50ng/mL, respectively. The average recoveries of BZPs from pooled serum samples spiked at 50 and 500ng/mL were 89.6-105.0% (RSD: 2.1-6.8%) and 93.6-110.4% (RSD: 2.1-4.2%), respectively, and those from urine samples were 88.7-105.5% (RSD: 2.9-6.4%) and 91.5-101.1% (RSD: 3.6-5.5%), respectively. SPDE-LC/TOF-MS has potential application in forensic science and emergency medicine. PMID:25126966

  17. Sensitive and rapid detection of Chlamydia trachomatis by recombinase polymerase amplification directly from urine samples.

    PubMed

    Krõlov, Katrin; Frolova, Jekaterina; Tudoran, Oana; Suhorutsenko, Julia; Lehto, Taavi; Sibul, Hiljar; Mäger, Imre; Laanpere, Made; Tulp, Indrek; Langel, Ülo

    2014-01-01

    Chlamydia trachomatis is the most common sexually transmitted human pathogen. Infection results in minimal to no symptoms in approximately two-thirds of women and therefore often goes undiagnosed. C. trachomatis infections are a major public health concern because of the potential severe long-term consequences, including an increased risk of ectopic pregnancy, chronic pelvic pain, and infertility. To date, several point-of-care tests have been developed for C. trachomatis diagnostics. Although many of them are fast and specific, they lack the required sensitivity for large-scale application. We describe a rapid and sensitive form of detection directly from urine samples. The assay uses recombinase polymerase amplification and has a minimum detection limit of 5 to 12 pathogens per test. Furthermore, it enables detection within 20 minutes directly from urine samples without DNA purification before the amplification reaction. Initial analysis of the assay from clinical patient samples had a specificity of 100% (95% CI, 92%-100%) and a sensitivity of 83% (95% CI, 51%-97%). The whole procedure is fairly simple and does not require specific machinery, making it potentially applicable in point-of-care settings. PMID:24331366

  18. Sulfatide Analysis by Mass Spectrometry for Screening of Metachromatic Leukodystrophy in Dried Blood and Urine Samples

    PubMed Central

    Spacil, Zdenek; Kumar, Arun Babu; Liao, Hsuan-Chieh; Auray-Blais, Christiane; Stark, Samantha; Suhr, Teryn R.; Scott, C. Ronald; Turecek, Frantisek; Gelb, Michael H.

    2016-01-01

    BACKGROUND Metachromatic leukodystrophy (MLD) is an autosomal recessive disorder caused by deficiency in arylsulfatase A activity, leading to accumulation of sulfatide substrates. Diagnostic and monitoring procedures include demonstration of reduced arylsulfatase A activity in peripheral blood leukocytes or detection of sulfatides in urine. However, the development of a screening test is challenging because of instability of the enzyme in dried blood spots (DBS), the widespread occurrence of pseudodeficiency alleles, and the lack of available urine samples from newborn screening programs. METHODS We measured individual sulfatide profiles in DBS and dried urine spots (DUS) from MLD patients with LC-MS/MS to identify markers with the discriminatory power to differentiate affected individuals from controls. We also developed a method for converting all sulfatide molecular species into a single species, allowing quantification in positive-ion mode upon derivatization. RESULTS In DBS from MLD patients, we found up to 23.2-fold and 5.1-fold differences in total sulfatide concentrations for early- and late-onset MLD, respectively, compared with controls and pseudodeficiencies. Corresponding DUS revealed up to 164-fold and 78-fold differences for early- and late-onset MLD patient samples compared with controls. The use of sulfatides converted to a single species simplified the analysis and increased detection sensitivity in positive-ion mode, providing a second option for sulfatide analysis. CONCLUSIONS This study of sulfatides in DBS and DUS suggests the feasibility of the mass spectrometry method for newborn screening of MLD and sets the stage for a larger-scale newborn screening pilot study. PMID:26585924

  19. Biological Monitoring of Human Exposure to Neonicotinoids Using Urine Samples, and Neonicotinoid Excretion Kinetics

    PubMed Central

    Harada, Kouji H.; Tanaka, Keiko; Sakamoto, Hiroko; Imanaka, Mie; Niisoe, Tamon; Hitomi, Toshiaki; Kobayashi, Hatasu; Okuda, Hiroko; Inoue, Sumiko; Kusakawa, Koichi; Oshima, Masayo; Watanabe, Kiyohiko; Yasojima, Makoto; Takasuga, Takumi; Koizumi, Akio

    2016-01-01

    Background Neonicotinoids, which are novel pesticides, have entered into usage around the world because they are selectively toxic to arthropods and relatively non-toxic to vertebrates. It has been suggested that several neonicotinoids cause neurodevelopmental toxicity in mammals. The aim was to establish the relationship between oral intake and urinary excretion of neonicotinoids by humans to facilitate biological monitoring, and to estimate dietary neonicotinoid intakes by Japanese adults. Methodology/Principal Findings Deuterium-labeled neonicotinoid (acetamiprid, clothianidin, dinotefuran, and imidacloprid) microdoses were orally ingested by nine healthy adults, and 24 h pooled urine samples were collected for 4 consecutive days after dosing. The excretion kinetics were modeled using one- and two-compartment models, then validated in a non-deuterium-labeled neonicotinoid microdose study involving 12 healthy adults. Increased urinary concentrations of labeled neonicotinoids were observed after dosing. Clothianidin was recovered unchanged within 3 days, and most dinotefuran was recovered unchanged within 1 day. Around 10% of the imidacloprid dose was excreted unchanged. Most of the acetamiprid was metabolized to desmethyl-acetamiprid. Spot urine samples from 373 Japanese adults were analyzed for neonicotinoids, and daily intakes were estimated. The estimated average daily intake of these neonicotinoids was 0.53–3.66 μg/day. The highest intake of any of the neonicotinoids in the study population was 64.5 μg/day for dinotefuran, and this was <1% of the acceptable daily intake. PMID:26731104

  20. Candidate biomarkers in exosome-like vesicles purified from rat and mouse urine samples

    PubMed Central

    Conde-Vancells, Javier; Rodriguez-Suarez, Eva; Gonzalez, Esperanza; Berisa, Agustin; Gil, David; Embade, Nieves; Valle, Mikel; Luka, Zigmund; Elortza, Felix; Wagner, Conrad; Lu, Shelly C.; Mato, Jose M.; Falcon-Perez, Juan M.

    2010-01-01

    Purpose There is a compelling clinical imperative to identify discerning molecular biomarkers of hepatic disease in order to inform the diagnosis, prognosis and treatment. Experimental design We have investigated the proteome of urinary vesicles present in urine samples obtained from experimental models for the study of liver injury, as an approach for identifying potential biomarkers for hepatic disease. Results The biochemical and proteomic characterization of highly purified exosome-like urinary vesicles has identified 28 proteins previously unreported in these vesicles, and many that have been previously associated with diseases, such as the prion-related protein. Furthermore, in urine samples from d-galactosamine-treated rats, a well-characterized experimental model for acute liver injury, we have detected a severe reduction in some proteins that normally are clearly detected in urinary vesicles. Finally, differential protein content on urinary vesicles from a mouse model for chronic liver injury has been also identified. Conclusions and clinical relevance Our results argue positively that urinary vesicles could be a source for identifying non-invasive biomarkers of liver injury. We proposed some proteins such as Cd26, Cd81, Slc3A1 and Cd10 that have been found to be differentially expressed in urinary vesicles from some of the analyzed models as potential biomarkers for liver injury. PMID:20535238

  1. Biological monitoring of metabolites of sarin and its by-products in human urine samples.

    PubMed

    Minami, M; Hui, D M; Wang, Z; Katsumata, M; Inagaki, H; Li, Q; Inuzuka, S; Mashiko, K; Yamamoto, Y; Ootsuka, T; Boulet, C A; Clement, J G

    1998-07-01

    More than 20,000 passengers of Tokyo underground trains were intoxicated with warfare toxic chemicals. Most of the patients examined had marked miosis and decreased serum cholinesterase activity. Transient increase of serum CPK activity after 3 days of the exposure was the another sign. We intensively analyzed the metabolites in the urine of 4 patients. The following analytic results indicated the exposure to sarin as well as contaminated compounds such as diisopropyl methylphosphonate (DIMP), ethyl methylphosphonate fluoridate (EMPF, or ethylsarin), diethyl methylphosphonate (DEMP), and ethyl isopropyl methylphosphonate (EIMP). (1) Isopropanol (IPA) and ethanol (EtOH) were detected of large quantities in the urine samples, and were thought to be derived from sarin and the sarin counterpart, EMPF, DIMP, DEMP and EIMP. (2) Monoalkyl methylphosphonic acids (isopropyl methylphosphonic acid (IMPA) and ethyl methylphosphonic acid (EMPA) also were excreted in large amounts with taking the similar excretion pattern of IPA and EtOH. (3) The metabolite only derived from sarin and ethylsarin is F anions whose integral output in the urine was less than the equimolar level of the excreted (IMPA + EMPA + IPA + EtOH). (4) Other corroborative findings were low lethality: of more than 5,510 patients treated, 11 were acutely dead. (5) Nine exposed males had higher sister chromatid exchange (SCE) rate (5.00 +/- 1.48/cell) than the control (3.81 +/- 0.697/cell), because dialkyl methylphosphonates seemed to have alkylating activity and producing DNA adducts. The SCE rate also increased after the in vitro exposure of lymphocytes to dialkyl methylphosphonates. PMID:9760476

  2. Validation of a Novel Collection Device for Non-Invasive Urine Sampling from Free-Ranging Animals

    PubMed Central

    Danish, Lisa Michelle; Heistermann, Michael; Agil, Muhammad; Engelhardt, Antje

    2015-01-01

    Recent advances in non-invasively collected samples have opened up new and exciting opportunities for wildlife research. Different types of samples, however, involve different limitations and certain physiological markers (e.g., C-peptide, oxytocin) can only be reliably measured from urine. Common collection methods for urine to date work best for arboreal animals and large volumes of urine. Sufficient recovery of urine is thus still difficult for wildlife biologists, particularly for terrestrial and small bodied animals. We tested three collection devices (two commercially available saliva swabs, Salivette synthetic and cotton, and cotton First aid swabs) against a control to permit the collection of small volumes of urine from the ground. We collected urine samples from captive and wild macaques, and humans, measured volume recovery, and analyzed concentrates of selected physiological markers (creatinine, C-peptide, and neopterin). The Salivette synthetic device was superior to the two alternative devices. Concentrations of creatinine, absolute C-peptide, C-peptide per creatinine, absolute neopterin, and neopterin per creatinine measured in samples collected with this device did not differ significantly from the control and were also strongly correlated to it. Fluid recovery was also best for this device. The least suitable device is the First aid collection device; we found that while absolute C-peptide and C-peptide per creatinine concentrations did not differ significantly from the control, creatinine concentrations were significantly lower than the control. In addition, these concentrations were either not or weakly correlated to the control. The Salivette cotton device provided intermediate results, although these concentrations were strongly correlated to the control. Salivette synthetic swabs seem to be useful devices for the collection of small amounts of urine from the ground destined for the assessment of physiological parameters. They thus provide new

  3. Determination of uranium 238 in urine samples for workers in the phosphate industry using alpha spectrometry

    NASA Astrophysics Data System (ADS)

    Kharita, M. H.; Bitar, A.; Sakhita, K.

    2013-02-01

    An alpha spectrometry method has been developed and validated to assess the internal dose from uranium isotopes for workers in phosphate mines. The method was able to measure levels down to 2 mBq/L. Though the validation results revealed that the mean relative error was about 20%, the method seems to be appropriate and suitable for the application of occupationally exposure monitoring. The method has been used for routine monitoring of workers in the Syrian phosphate mines for 2 years. The results showed that there was some high activity of uranium 238 in urine samples of the first batch which was attributed to samples contamination from the work environment. In the second batch, the results showed that the activity of uranium 238 for most workers were less than the detection limit. Nevertheless, some workers had some exposures but the calculated doses were low or within the occupational dose limit.

  4. Screening for proteinuria in a rheumatology clinic: comparison of dipstick testing, 24 hour urine quantitative protein, and protein/creatinine ratio in random urine samples.

    PubMed

    Ralston, S H; Caine, N; Richards, I; O'Reilly, D; Sturrock, R D; Capell, H A

    1988-09-01

    Measurements of protein/creatinine ratio in 'spot' urine samples were compared with measurements of 24 hour quantitative proteinuria and side room 'dipstick' testing in 104 samples from 90 patients presenting consecutively to a rheumatology unit. Linear regression analysis showed a highly significant correlation between the random urinary protein/creatinine ratio and total protein excretion in 24 hour urine samples (r = 0.92, p less than 0.001, y = 6.55x + 0.04). Although an approximation of 24 hour urinary protein excretion could have been made from the regression line: 24 hour urine protein = 6.55 x protein/creatinine ratio + 0.04 (g/l), there was a wide scatter of values, particularly in patients with greater than 1 g/24 h urinary protein excretion. Nevertheless, significant proteinuria (greater than 300 mg/24 h) could have been confirmed or excluded with a sensitivity and specificity of 97% by adopting random protein/creatinine values of less than 0.04 as 'normal'. Specificity and sensitivity could have been increased to 100%, however, by excluding patients with values lying between 0.01 and 0.10 as all the false negatives (n = 3) and false positives (n = 3) lay within this range. In comparison, dipstick testing, although 100% sensitive, had a poor specificity due to the high false positive rate (40/83 (48%] in patients with 1+ to 3+ readings. Assessment of random urinary protein/creatinine ratio may obviate the need for 24 hour urine collections in the initial assessment of suspected proteinuria. A wider application of this technique seems indicated in view of the obvious advantages in terms of cost, time, and patient convenience. PMID:3263087

  5. Seasonal variation in natural abundance of 2H and 18O in urine samples from rural Nigeria

    PubMed Central

    Dugas, Lara R.; Brieger, William; Tayo, Bamidele O.; Alabi, Tunrayo; Schoeller, Dale A.; Luke, Amy

    2015-01-01

    The doubly labeled water (DLW) method is used to measure free-living energy expenditure in humans. Inherent to this technique is the assumption that natural abundances of stable isotopes 2H and 18O in body water remain constant over the course of the measurement period and after elimination of the loading dose of DLW will return to the same predose level. To determine variability in the natural abundances of 2H and 18O in humans living in a region with seasonal shifts in rain patterns and sources of drinking water, over the course of 12 mo we collected weekly urine samples from four individuals living in southwest Nigeria as well as samples of their drinking water. From ongoing regional studies of hypertension, obesity, and energy expenditure, we estimated average water turnover rate, urine volumes, and sodium and potassium excretion. Results suggest that 2H and 18O in urine, mean concentrations of urinary sodium and potassium, urine volume, and total body turnover differed significantly from dry to rainy season. Additionally, seasonal weather variables (mean monthly maximum temperatures, total monthly rainfall, and minimum relative humidity) were all significantly associated with natural abundances in urine. No seasonal difference was observed in drinking water samples. Findings suggest that natural abundances in urine may not remain constant as assumed, and studies incorporating DLW measurements across the transition of seasons should interpret results with caution unless appropriate doses of the tracers are used. PMID:25977450

  6. Osmolality urine test

    MedlinePlus

    ... and urine concentration. Osmolality is a more exact measurement of urine concentration than the urine specific gravity ... slightly among different laboratories. Some labs use different measurements or test different samples. Talk to your provider ...

  7. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    NASA Astrophysics Data System (ADS)

    Hernández-Mendoza, H.; Chamizo, E.; Yllera, A.; García-León, M.; Delgado, A.

    2010-04-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the "classical" preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the "classical" methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  8. Immunofixation - urine

    MedlinePlus

    ... need to supply a clean-catch (midstream) urine sample. Clean the area around where urine leaves the body. Men or boys should wipe the head of the penis. Women or girls should wash the area between the lips of the vagina with soapy water and rinse well. Allow a small amount to ...

  9. The examination of urine samples for pathogenic microbes by the luciferase assay for ATP. 1: The effect of the presence of fungi, fungal like bacteria and kidney cells in urine samples

    NASA Technical Reports Server (NTRS)

    Bush, V. N.

    1973-01-01

    A method for accurately determining urinary tract infections in man is introduced. The method is based on adenosine triphosphate (ATP) concentration in urine samples after removing nonbacterial ATP. Adenosine triphosphate concentration is measured from the bioluminescent reaction of luciferase when mixed with ATP. An examination was also made of the effectiveness of rupturing agents on monkey kidney cells Candia albicans, a Rhodotorula species, and a Streptomyces species in determining whether these cells could contribute ATP to the bacterial ATP value of a urine sample.

  10. Genotyping of Leptospira directly in urine samples of cattle demonstrates a diversity of species and strains in Brazil.

    PubMed

    Hamond, C; Pestana, C P; Medeiros, M A; Lilenbaum, W

    2016-01-01

    The aim of this study was to identify Leptospira in urine samples of cattle by direct sequencing of the secY gene. The validity of this approach was assessed using ten Leptospira strains obtained from cattle in Brazil and 77 DNA samples previously extracted from cattle urine, that were positive by PCR for the genus-specific lipL32 gene of Leptospira. Direct sequencing identified 24 (31·1%) interpretable secY sequences and these were identical to those obtained from direct DNA sequencing of the urine samples from which they were recovered. Phylogenetic analyses identified four species: L. interrogans, L. borgpetersenii, L. noguchii, and L. santarosai with the most prevalent genotypes being associated with L. borgpetersenii. While direct sequencing cannot, as yet, replace culturing of leptospires, it is a valid additional tool for epidemiological studies. An unexpected finding from this study was the genetic diversity of Leptospira infecting Brazilian cattle. PMID:26076668

  11. Chemical concentration measurement in blood serum and urine samples using liquid-core optical fiber Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Qi, Dahu; Berger, Andrew J.

    2007-04-01

    We report measurements of chemical concentrations in clinical blood serum and urine samples using liquid-core optical fiber (LCOF) Raman spectroscopy to increase the collected signal strength. Both Raman and absorption spectra were acquired in the near-infrared region using the LCOF geometry. Spectra of 71 blood serum and 61 urine samples were regressed via partial least squares against reference analyzer values. Significant correlation was found between predicted and reference concentrations for 13 chemicals. Using absorption data to normalize the LCOF enhancement made the results more accurate. The experimental geometry is well suited for high-volume and automated chemical analysis of clear biofluids.

  12. Monitoring exposure to polycyclic aromatic hydrocarbons in an Australian population using pooled urine samples.

    PubMed

    Thai, Phong K; Heffernan, Amy L; Toms, Leisa-Maree L; Li, Zheng; Calafat, Antonia M; Hobson, Peter; Broomhall, Sara; Mueller, Jochen F

    2016-03-01

    Integrated exposure to polycyclic aromatic hydrocarbons (PAHs) can be assessed through monitoring of urinary mono-hydroxylated PAHs (OH-PAHs). The aim of this study was to provide the first assessment of exposure to PAHs in a large sample of the population in Queensland, Australia including exposure to infant (0-4years). De-identified urine specimens, obtained from a pathology laboratory, were stratified by age and sex, and pooled (n=24 pools of 100) and OH-PAHs were measured by gas chromatography-isotope dilution-tandem mass spectrometry. Geometric mean (GM) concentrations ranged from 30ng/L (4-hydroxyphenanthrene) to 9221ng/L (1-naphthol). GM of 1-hydroxypyrene, the most commonly used PAH exposure biomarker, was 142ng/L. The concentrations of OH-PAHs found in this study are consistent with those in developed countries and lower than those in developing countries. We observed no association between sex and OH-PAH concentrations. However, we observed lower urinary concentrations of all OH-PAHs in samples from infants (0-4years), children (5-14years) and the elderly (>60year old) compared with samples from other age groups (15-29, 30-44 and 45-59years) which may be attributed to age-dependent behaviour-specific exposure sources. PMID:26700419

  13. Uptake of gamma-valerolactone--detection of gamma-hydroxyvaleric acid in human urine samples.

    PubMed

    Andresen-Streichert, H; Jungen, H; Gehl, A; Müller, A; Iwersen-Bergmann, S

    2013-05-01

    Gamma-valerolactone (GVL) is reported to be a substance that can be used as a legal substitute for gamma-hydroxybutyric acid (GHB), which is currently a controlled substance in several countries. Unlike gamma-butyrolactone and 1,4-butanediol, GVL is not metabolized to GHB, which causes the effects after uptake of these two chemicals. In the case of GVL, the lactone ring is split to gamma-hydroxyvaleric acid (GHV or 4-methyl-GHB) by a lactonase. Because of its affinity for the GHB receptor, GHV reveals similar effects to GHB, although it is less potent. Intoxications with GVL, or its use as a date rape drug, are conceivable. Despite these facts, there are no publications in the literature regarding detections of GHV in human samples. This study reports three cases, including five urine samples, in which GHV could be detected in concentrations between 3 and 5.8 mg/L. In one of these cases, a drug-facilitated sexual assault (DFSA) was assumed; four of these samples were from two people suspected of abusing GHB. The results indicate that GVL is used as an alternative to GHB and its precursors and should be taken seriously. GVL or GHV should be included in toxicological analysis, particularly in DFSA cases. More information is needed regarding the pharmacokinetics of GVL/GHV for the meaningful interpretation of positive or negative results. PMID:23486087

  14. Detection of p-chloroamphetamine in urine samples with mass spectrometry.

    PubMed

    Lin, Tsz C; Lin, Dong-Liang; Lua, Ahai C

    2011-05-01

    Designer drugs are introduced periodically to avoid detection and to provide new drugs with different pharmacological activities. During our routine analysis of amphetamine in urine samples, we observed one sample that reacted with immunoassay with high activity. There is one prominent peak in the gas chromatography- mass spectrometry (GC-MS) chromatogram. However, no amphetamine, methamphetamine, MDA, MDMA, MDEA, or ephedrine was detected with GC-MS. Careful examination of the mass spectrum indicated the presence of one fragment ion (m/z 140), which is similar to the base peak of trifluoroacetic anhydride derivative of amphetamine. The characteristic ion cluster representing the presence of one chlorine atom was observed. Investigation with liquid chromatography (LC)-MS detected an unknown compound with molecular ion of m/z 170. This compound was tentatively identified as chloroamphetamine. Pure standard material of p-chloroamphetamine (PCA) was purchased and analyzed with both GC-MS and LC-MS. Identical GC-MS spectra and LC-MS-MS fragmentation patterns were obtained. A GC-MS procedure was developed for the quantitation of PCA. The limits of detection and quantification were 10 μg/L. Precision was between 1.26% and 4.26%, and bias was between -0.91% and 4.27%. The prevalence PCA positive rate is 0.35% of the samples screened positive for amphetamine. PMID:21513613

  15. Direct derivatization and gas chromatography-tandem mass spectrometry identification of nerve agent biomarkers in urine samples.

    PubMed

    Subramaniam, Raja; Östin, Anders; Nilsson, Calle; Åstot, Crister

    2013-06-01

    Rapid determination of nerve agent biomarkers at low-ppb levels in urine samples was achieved by direct derivatization and sample analysis using gas chromatography-tandem mass spectrometry. The studied biomarkers were alkylphosphonic acids (APAs), as they are specific hydrolysis products of organophosphorus nerve agents that can be used to verify nerve agent exposure. The sample preparation technique employed involves rapid direct derivatization (5min) of acidified urine samples (25μL) using a highly fluorinated phenyldiazomethane reagent [1-(diazomethyl)-3,5-bis(trifluoromethyl)benzene]. The derivatization conditions were optimized using statistical experimental design and multivariate data analysis. The APA derivatives were analyzed by GC-MS and MS/MS using negative ion chemical ionization. The selectivity and sensitivity of analyses performed by low and high resolution single ion monitoring MS-mode were compared with those performed by multiple reaction monitoring MS/MS-mode. The MS/MS technique offered the greatest sensitivity and selectivity of the tested mass spectrometric techniques, with limits of detection ranging from 0.5 to 1ng APAs/mL of urine. The method's robustness was evaluated using urine samples from the OPCW 2nd biomedical confidence building exercise and all APAs present in the samples were conclusively identified. The method thus offers excellent performance and is viable for the simultaneous trace determination of a wide range of nerve agent markers. PMID:23603296

  16. Simple and rapid sample preparation system for the molecular detection of antibiotic resistant pathogens in human urine.

    PubMed

    Valiadi, Martha; Kalsi, Sumit; Jones, Isaac G F; Turner, Carrie; Sutton, J Mark; Morgan, Hywel

    2016-02-01

    Antibiotic resistance in urinary tract infections (UTIs) can cause significant complications without quick detection and appropriate treatment. We describe a new approach to capture, concentrate and prepare amplification-ready DNA from antibiotic resistant bacteria in human urine samples. Klebsiella pneumoniae NCTC13443 (bla CTX-M-15 positive) spiked into filtered human urine was used as a model system. Bacteria were captured using anion exchange diaethylaminoethyl (DEAE) magnetic microparticles and concentrated 200-fold within ~3.5 min using a custom, valve-less microfluidic chip. Eight samples were processed in parallel, and DNA was released using heat lysis from an integrated resistive heater. The crude cell lysate was used for real time Recombinase Polymerase Amplification (RPA) of the bla CTX-M-15 gene. The end to end processing time was approximately 15 min with a limit of detection of 1000 bacteria in 1 mL urine. PMID:26846875

  17. Parabens in 24 h urine samples of the German Environmental Specimen Bank from 1995 to 2012.

    PubMed

    Moos, Rebecca K; Koch, Holger M; Angerer, Jürgen; Apel, Petra; Schröter-Kermani, Christa; Brüning, Thomas; Kolossa-Gehring, Marike

    2015-10-01

    Parabens are widely used as antimicrobial preservatives in personal care and consumer products, food and pharmaceuticals. Due to their ubiquity, humans are constantly exposed to these chemicals. We assessed exposure to nine parabens (methyl-, ethyl-, n- and iso-propyl-, n- and iso-butyl-, benzyl-, pentyl- and heptyl paraben) in the German population from 1995 to 2012 based on 660 24h urine samples from the German Environmental Specimen Bank (ESB) using on-line HPLC coupled to isotope dilution tandem mass spectrometry. The limit of quantification (LOQ) was 0.5 μg/L for all parabens. We detected methyl-, ethyl- and n-propyl paraben in 79-99% of samples, followed by n-butyl paraben in 40% of samples. We infrequently detected iso-butyl-, iso-propyl- and benzyl paraben in 24%, 4% and 1.4% of samples, respectively. Urinary concentrations were highest for methyl paraben (median 39.8 μg/L; 95th percentile 319 μg/L) followed by n-propyl paraben (4.8 μg/L; 95th percentile 74.0 μg/L) and ethyl paraben (2.1 μg/L; 95th percentile 39.1 μg/L). Women had significantly higher urinary levels for all parabens than men, except for benzyl paraben. Samples from the ESB revealed that over the investigation period of nearly 20 years urinary paraben levels remained surprisingly constant; only methyl paraben had a significant increase, for both men and women. We found strong correlations between methyl- and n-propyl paraben and between n- and iso-butyl paraben. These results indicate that parabens are used in combination and arise from common sources of exposure. Urinary excretion factors are needed to extrapolate from individual urinary concentrations to actual doses. PMID:26253560

  18. Validation and Assessment of Three Methods to Estimate 24-h Urinary Sodium Excretion from Spot Urine Samples in Chinese Adults.

    PubMed

    Peng, Yaguang; Li, Wei; Wang, Yang; Chen, Hui; Bo, Jian; Wang, Xingyu; Liu, Lisheng

    2016-01-01

    24-h urinary sodium excretion is the gold standard for evaluating dietary sodium intake, but it is often not feasible in large epidemiological studies due to high participant burden and cost. Three methods-Kawasaki, INTERSALT, and Tanaka-have been proposed to estimate 24-h urinary sodium excretion from a spot urine sample, but these methods have not been validated in the general Chinese population. This aim of this study was to assess the validity of three methods for estimating 24-h urinary sodium excretion using spot urine samples against measured 24-h urinary sodium excretion in a Chinese sample population. Data are from a substudy of the Prospective Urban Rural Epidemiology (PURE) study that enrolled 120 participants aged 35 to 70 years and collected their morning fasting urine and 24-h urine specimens. Bias calculations (estimated values minus measured values) and Bland-Altman plots were used to assess the validity of the three estimation methods. 116 participants were included in the final analysis. Mean bias for the Kawasaki method was -740 mg/day (95% CI: -1219, 262 mg/day), and was the lowest among the three methods. Mean bias for the Tanaka method was -2305 mg/day (95% CI: -2735, 1875 mg/day). Mean bias for the INTERSALT method was -2797 mg/day (95% CI: -3245, 2349 mg/day), and was the highest of the three methods. Bland-Altman plots indicated that all three methods underestimated 24-h urinary sodium excretion. The Kawasaki, INTERSALT and Tanaka methods for estimation of 24-h urinary sodium excretion using spot urines all underestimated true 24-h urinary sodium excretion in this sample of Chinese adults. Among the three methods, the Kawasaki method was least biased, but was still relatively inaccurate. A more accurate method is needed to estimate the 24-h urinary sodium excretion from spot urine for assessment of dietary sodium intake in China. PMID:26895296

  19. Validation and Assessment of Three Methods to Estimate 24-h Urinary Sodium Excretion from Spot Urine Samples in Chinese Adults

    PubMed Central

    Peng, Yaguang; Li, Wei; Wang, Yang; Chen, Hui; Bo, Jian; Wang, Xingyu; Liu, Lisheng

    2016-01-01

    24-h urinary sodium excretion is the gold standard for evaluating dietary sodium intake, but it is often not feasible in large epidemiological studies due to high participant burden and cost. Three methods—Kawasaki, INTERSALT, and Tanaka—have been proposed to estimate 24-h urinary sodium excretion from a spot urine sample, but these methods have not been validated in the general Chinese population. This aim of this study was to assess the validity of three methods for estimating 24-h urinary sodium excretion using spot urine samples against measured 24-h urinary sodium excretion in a Chinese sample population. Data are from a substudy of the Prospective Urban Rural Epidemiology (PURE) study that enrolled 120 participants aged 35 to 70 years and collected their morning fasting urine and 24-h urine specimens. Bias calculations (estimated values minus measured values) and Bland-Altman plots were used to assess the validity of the three estimation methods. 116 participants were included in the final analysis. Mean bias for the Kawasaki method was -740 mg/day (95% CI: -1219, 262 mg/day), and was the lowest among the three methods. Mean bias for the Tanaka method was -2305 mg/day (95% CI: -2735, 1875 mg/day). Mean bias for the INTERSALT method was -2797 mg/day (95% CI: -3245, 2349 mg/day), and was the highest of the three methods. Bland-Altman plots indicated that all three methods underestimated 24-h urinary sodium excretion. The Kawasaki, INTERSALT and Tanaka methods for estimation of 24-h urinary sodium excretion using spot urines all underestimated true 24-h urinary sodium excretion in this sample of Chinese adults. Among the three methods, the Kawasaki method was least biased, but was still relatively inaccurate. A more accurate method is needed to estimate the 24-h urinary sodium excretion from spot urine for assessment of dietary sodium intake in China. PMID:26895296

  20. Thio-dimethylarsinate is a common metabolite in urine samples from arsenic-exposed women in Bangladesh

    SciTech Connect

    Raml, Reingard; Rumpler, Alice; Goessler, Walter; Vahter, Marie; Li Li; Ochi, Takafumi; Francesconi, Kevin A.

    2007-08-01

    Over the last 6 years, much work on arsenic species in urine samples has been directed toward the determination of the reduced dimethylated arsenic species, DMA(III), because of its high toxicity and perceived key role in the metabolism of inorganic arsenic. Recent work, however, has suggested that DMA(III) may at times have been misidentified because its chromatographic properties can be similar to those of thio-dimethylarsinate (thio-DMA). We analyzed by HPLC-ICPMS (inductively coupled plasma mass spectrometry) urine samples from 75 arsenic-exposed women from Bangladesh with total arsenic concentrations ranging from 8 to 1034 {mu}g As/L and found that thio-DMA was present in 44% of the samples at concentrations ranging mostly from trace amounts to 24 {mu}g As/L (one sample contained 123 {mu}g As/L). Cytotoxicity testing with HepG2 cells derived from human hepatocarcinoma indicated that thio-DMA was about 10-fold more cytotoxic than dimethylarsinate (DMA). The widespread occurrence of thio-DMA in urine from these arsenic-exposed women suggests that this arsenical may also be present in other urine samples and has so far escaped detection. The work highlights the need for analytical methods providing specific determinations of arsenic compounds in future studies on arsenic metabolism and toxicology.

  1. Calcium Isolation from Large-Volume Human Urine Samples for 41Ca Analysis by Accelerator Mass Spectrometry

    PubMed Central

    Miller, James J; Hui, Susanta K; Jackson, George S; Clark, Sara P; Einstein, Jane; Weaver, Connie M; Bhattacharyya, Maryka H

    2013-01-01

    Calcium oxalate precipitation is the first step in preparation of biological samples for 41Ca analysis by accelerator mass spectrometry. A simplified protocol for large-volume human urine samples was characterized, with statistically significant increases in ion current and decreases in interference. This large-volume assay minimizes cost and effort and maximizes time after 41Ca administration during which human samples, collected over a lifetime, provide 41Ca:Ca ratios that are significantly above background. PMID:23672965

  2. Temporal variability of pyrethroid metabolite levels in bedtime, morning, and 24-h urine samples for 50 adults in North Carolina.

    PubMed

    Morgan, Marsha K; Sobus, Jon R; Barr, Dana Boyd; Croghan, Carry W; Chen, Fu-Lin; Walker, Richard; Alston, Lillian; Andersen, Erik; Clifton, Matthew S

    2016-01-01

    Pyrethroid insecticides are widely used to control insects in both agricultural and residential settings worldwide. Few data are available on the temporal variability of pyrethroid metabolites in the urine of non-occupationally exposed adults. In this work, we describe the study design and sampling methodology for the Pilot Study to Estimate Human Exposures to Pyrethroids using an Exposure Reconstruction Approach (Ex-R study). Two major objectives were to quantify the concentrations of several pyrethroid metabolites in bedtime, first morning void (FMV), and 24-h urine samples as concentration (wet weight), specific-gravity (SG) corrected, creatinine (CR) corrected, and excretion rate values for 50 Ex-R adults over a six-week monitoring period and to determine if these correction approaches for urine dilution reduced the variability of the biomarker levels. The Ex-R study was conducted at the United States Environmental Protection Agency's Human Studies Facility in Chapel Hill, North Carolina USA and at participants' homes within a 40-mile radius of this facility. Recruitment of participants and field activities occurred between October 2009 and May 2011. Participants, ages 19-50 years old, provided daily food, activity, and pesticide-use diaries and collected their own urine samples (bedtime, FMV, and 24-h) during weeks 1, 2, and 6 of a six-week monitoring period. A total of 2503 urine samples were collected from the study participants. These samples were analyzed for the pyrethroid metabolites 3-phenoxybenzoic acid (3-PBA), cis/trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-cyclopropane carboxylic acid (cis/trans-DCCA), and 2-methyl-3-phenylbenzoic acid (MPA) using high performance liquid chromatography/tandem mass spectrometry. Only 3-PBA was frequently detected (>50%) in the adult urine samples. Median urinary 3-PBA levels were 0.88 ng/mL, 0.96 ng/mL-SG, 1.04 ng/mg, and 1.04 ng/min for concentration, SG-corrected, CR-corrected, and excretion rate values, respectively

  3. Capillary electrochromatography-mass spectrometry for the determination of 5-nitroimidazole antibiotics in urine samples.

    PubMed

    Hernández-Mesa, Maykel; D'Orazio, Giovanni; Rocco, Anna; García-Campaña, Ana M; Blanco, Carmen Cruces; Fanali, Salvatore

    2015-10-01

    The separation of eight antibiotics belonging to 5-nitroimidazole family was carried out by means of CEC coupled with MS. Preliminary experiments were carried out with ultraviolet detection in order to select the proper stationary and mobile phase. Among the different stationary phases studied (namely Lichrospher C18, 5 μm particle size; Cogent(TM) Bidentate C18, 4.2 μm; Pinnacle II™ Phenyl, 3 μm; Pinnacle II™ Cyano, 3 μm), Cogent™ Bidentate C18 (4.2 μm) gave the best performance. For CEC-MS coupling, a laboratory assembled liquid-junction-nano-spray interface was used. In order to achieve a good sensitivity, special attention was paid to both optimization of the sheath liquid composition as well as selection of the injection mode. Under optimized CEC-ESI-MS conditions, the separation was accomplished within 22 min by using a column packed with a mixture of Bidentate C18:Lichrospher Silica-60 (5 μm) 3:1 w/w, an inlet pressure of 11 bar, a voltage of 15 kV, and a mobile phase composed by 45:10:45 v/v/v ACN/MeOH/water containing ammonium acetate (5 mM pH 5). A combined hydrodynamic and electrokinetic injection of 8 bar, 15 kV, and 96 s was adopted. The method was validated in terms of repeatability and intermediate precision of retention times and peak areas, linearity, and LODs and LOQs. RSDs values were <2.9% for retention times and <16.1% for peak areas in both intraday and interday experiments. LOQ values were between 0.09 and 0.42 μg/mL for all compounds. Finally, the method was applied to the determination of three most employed 5-nitroimidazole antibiotics (metronidazole, secnidazole, and ternidazole) in spiked urine samples, subjected to a SPE procedure. Recovery values in the 67-103% range were obtained. Furthermore, for the selected antibiotics, CEC-MS(2) spectra were obtained providing the unambiguous confirmation of these drugs in urine samples. PMID:26200811

  4. Overcoming non-specific adsorption issues for AZD9164 in human urine samples: consideration of bioanalytical and metabolite identification procedures.

    PubMed

    Silvester, Steve; Zang, Frank

    2012-04-15

    A key challenge in the development of robust bioanalytical methods, for the determination of drug analyte in human urine samples, is the elimination of potential analyte losses as a result of non-specific adsorption to container surfaces in which the samples are collected, stored or processed. A common approach to address adsorption issues is to treat the urine samples with additives that serve to increase analyte solubility and/or minimise interaction with the container surfaces. A series of adsorption experiments were performed on human urine samples containing an adsorption-prone in-house development compound (AZD9164). A roller-mixing methodology was employed to maximise sample interaction with container surfaces and quantification of analyte was performed by LC-MS/MS following minimal sample preparation. In the absence of any urine additive, adsorptive losses averaged 35% but were highly variable between different lots of urine. In the presence of a range of additives, including the surfactants Tween 80, 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulphonate (CHAPS) and sodium dodecylbenzenesulphonate (SDBS), analyte adsorption was shown to be eliminated. Of particular academic interest was the finding that adsorptive losses could also be reduced upon the addition of phospholipid. The presence of additive generally had no marked impact on the analyte MS response but the use of an isotopically labelled internal standard satisfactorily compensated for instances in which ion suppression was observed, e.g. in the presence of Tween 80. Since metabolite profiling/identification investigations are often performed on urine samples originating from early clinical pharmacology studies, the elution of selected additives was also monitored by MS. CHAPS, dimethylacetamide (DMA) and HP-β-cyclodextrin eluted as single chromatographic peaks in, or just after, the column void volume whilst polymeric Tween 80, and to a lesser extent SDBS, eluted over a wide retention time

  5. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry.

    PubMed

    Crevelin, Eduardo J; Salami, Fernanda H; Alves, Marcela N R; De Martinis, Bruno S; Crotti, Antônio E M; Moraes, Luiz A B

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications. Graphical Abstract ᅟ. PMID:26907179

  6. Direct Analysis of Amphetamine Stimulants in a Whole Urine Sample by Atmospheric Solids Analysis Probe Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Crevelin, Eduardo J.; Salami, Fernanda H.; Alves, Marcela N. R.; De Martinis, Bruno S.; Crotti, Antônio E. M.; Moraes, Luiz A. B.

    2016-05-01

    Amphetamine-type stimulants (ATS) are among illicit stimulant drugs that are most often used worldwide. A major challenge is to develop a fast and efficient methodology involving minimal sample preparation to analyze ATS in biological fluids. In this study, a urine pool solution containing amphetamine, methamphetamine, ephedrine, sibutramine, and fenfluramine at concentrations ranging from 0.5 pg/mL to 100 ng/mL was prepared and analyzed by atmospheric solids analysis probe tandem mass spectrometry (ASAP-MS/MS) and multiple reaction monitoring (MRM). A urine sample and saliva collected from a volunteer contributor (V1) were also analyzed. The limit of detection of the tested compounds ranged between 0.002 and 0.4 ng/mL in urine samples; the signal-to-noise ratio was 5. These results demonstrated that the ASAP-MS/MS methodology is applicable for the fast detection of ATS in urine samples with great sensitivity and specificity, without the need for cleanup, preconcentration, or chromatographic separation. Thus ASAP-MS/MS could potentially be used in clinical and forensic toxicology applications.

  7. Functionalized graphene oxide for clinical glucose biosensing in urine and serum samples

    PubMed Central

    Veerapandian, Murugan; Seo, Yeong-Tai; Shin, Hyunkyung; Yun, Kyusik; Lee, Min-Ho

    2012-01-01

    A novel clinical glucose biosensor fabricated using functionalized metalloid-polymer (silver-silica coated with polyethylene glycol) hybrid nanoparticles on the surface of a graphene oxide nanosheet is reported. The cyclic voltammetric response of glucose oxidase modification on the surface of a functionalized graphene oxide electrode showed a surface-confined reaction and an effective redox potential near zero volts, with a wide linearity of 0.1–20 mM and a sensitivity of 7.66 μA mM−1 cm−2. The functionalized graphene oxide electrode showed a better electrocatalytic response toward oxidation of H2O2 and reduction of oxygen. The practical applicability of the functionalized graphene oxide electrode was demonstrated by measuring the peak current against multiple urine and serum samples from diabetic patients. This new hybrid nanoarchitecture combining a three-dimensional metalloid-polymer hybrid and two-dimensional graphene oxide provided a thin solid laminate on the electrode surface. The easy fabrication process and retention of bioactive immobilized enzymes on the functionalized graphene oxide electrode could potentially be extended to detection of other biomolecules, and have broad applications in electrochemical biosensing. PMID:23269871

  8. Functionalized graphene oxide for clinical glucose biosensing in urine and serum samples.

    PubMed

    Veerapandian, Murugan; Seo, Yeong-Tai; Shin, Hyunkyung; Yun, Kyusik; Lee, Min-Ho

    2012-01-01

    A novel clinical glucose biosensor fabricated using functionalized metalloid-polymer (silver-silica coated with polyethylene glycol) hybrid nanoparticles on the surface of a graphene oxide nanosheet is reported. The cyclic voltammetric response of glucose oxidase modification on the surface of a functionalized graphene oxide electrode showed a surface-confined reaction and an effective redox potential near zero volts, with a wide linearity of 0.1-20 mM and a sensitivity of 7.66 μA mM(-1) cm(-2). The functionalized graphene oxide electrode showed a better electrocatalytic response toward oxidation of H(2)O(2) and reduction of oxygen. The practical applicability of the functionalized graphene oxide electrode was demonstrated by measuring the peak current against multiple urine and serum samples from diabetic patients. This new hybrid nanoarchitecture combining a three-dimensional metalloid-polymer hybrid and two-dimensional graphene oxide provided a thin solid laminate on the electrode surface. The easy fabrication process and retention of bioactive immobilized enzymes on the functionalized graphene oxide electrode could potentially be extended to detection of other biomolecules, and have broad applications in electrochemical biosensing. PMID:23269871

  9. Silver nanoparticles enhanced flow injection chemiluminescence determination of gatifloxacin in pharmaceutical formulation and spiked urine sample

    NASA Astrophysics Data System (ADS)

    Wabaidur, Saikh mohammad; Alam, Seikh Mafiz; Alothman, Zeid A.; Mohsin, Kazi

    2015-06-01

    Silver nanoparticles have been utilized for the enhanced chemiluminogenic estimation of fluoroquinolone antibiotic gatifloxacin. It has been found that the weak chemiluminescence intensity produced from the reaction between calcein and KMnO4 can further be strengthened by the addition of silver nanoparticles in the presence of gatifloxacin. This phenomenon has been exploited to the quantitative determination of gatifloxacin. Under the optimum experimental conditions, the calibration curves are linear over the range of 8.9 × 10-9-4.0 × 10-6 M, while the limits of detections were found to be 2.6 × 10-9 M with correlation coefficient value (r2) 0.9999. The relative standard deviation calculated from six replicate measurements (1.0 × 10-4 M gatifloxacin) was 1.70%. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled on the formulations. The proposed method was also used for the determination of gatifloxacin in spiked urine samples with satisfactory results. No interference effects from some common excipients used in pharmaceutical preparations have been found.

  10. Silver nanoparticles enhanced flow injection chemiluminescence determination of gatifloxacin in pharmaceutical formulation and spiked urine sample.

    PubMed

    Wabaidur, Saikh mohammad; Alam, Seikh Mafiz; Alothman, Zeid A; Mohsin, Kazi

    2015-06-01

    Silver nanoparticles have been utilized for the enhanced chemiluminogenic estimation of fluoroquinolone antibiotic gatifloxacin. It has been found that the weak chemiluminescence intensity produced from the reaction between calcein and KMnO4 can further be strengthened by the addition of silver nanoparticles in the presence of gatifloxacin. This phenomenon has been exploited to the quantitative determination of gatifloxacin. Under the optimum experimental conditions, the calibration curves are linear over the range of 8.9×10(-9)-4.0×10(-6) M, while the limits of detections were found to be 2.6×10(-9) M with correlation coefficient value (r(2)) 0.9999. The relative standard deviation calculated from six replicate measurements (1.0×10(-4) M gatifloxacin) was 1.70%. The method was applied to pharmaceutical preparations and the results obtained were in reasonable agreement with the amount labeled on the formulations. The proposed method was also used for the determination of gatifloxacin in spiked urine samples with satisfactory results. No interference effects from some common excipients used in pharmaceutical preparations have been found. PMID:25754393

  11. Molecularly imprinted solid-phase extraction of glutathione from urine samples.

    PubMed

    Song, Renyuan; Hu, Xiaoling; Guan, Ping; Li, Ji; Zhao, Na; Wang, Qiaoli

    2014-11-01

    Molecularly imprinted polymer (MIP) particles for glutathione were synthesized through iniferter-controlled living radical precipitation polymerization (IRPP) under ultraviolet radiation at ambient temperature. Static adsorption, solid-phase extraction, and high-performance liquid chromatography were carried out to evaluate the adsorption properties and selective recognition characteristics of the polymers for glutathione and its structural analogs. The obtained IRPP-MIP particles exhibited a regularly spherical shape, rapid binding kinetics, high imprinting factor, and high selectivity compared with the MIP particles prepared using traditional free-radical precipitation polymerization. The selective separation and enrichment of glutathione from the mixture of glycyl-glycine and glutathione disulfide could be achieved on the IRPP-MIP cartridge. The recoveries of glutathione, glycyl-glycine, and glutathione disulfide were 95.6% ± 3.65%, 29.5% ± 1.26%, and 49.9% ± 1.71%, respectively. The detection limit (S/N=3) of glutathione was 0.5 mg·L(-1). The relative standard deviations (RSDs) for 10 replicate detections of 50 mg·L(-1) of glutathione were 5.76%, and the linear range of the calibration curve was 0.5 mg·L(-1) to 200 mg·L(-1) under optimized conditions. The proposed approach was successfully applied to determine glutathione in spiked human urine samples with recoveries of 90.24% to 96.20% and RSDs of 0.48% to 5.67%. PMID:25280681

  12. Development of a Rapid PCR Assay Specific for Staphylococcus saprophyticus and Application to Direct Detection from Urine Samples

    PubMed Central

    Martineau, Francis; Picard, François J.; Ménard, Christian; Roy, Paul H.; Ouellette, Marc; Bergeron, Michel G.

    2000-01-01

    Staphylococcus saprophyticus is one of the most frequently encountered microorganisms associated with acute urinary tract infections (UTIs) in young, sexually active female outpatients. Conventional identification methods based on biochemical characteristics can efficiently identify S. saprophyticus, but the rapidities of these methods need to be improved. Rapid and direct identification of this bacterium from urine samples would be useful to improve time required for the diagnosis of S. saprophyticus infections in the clinical microbiology laboratory. We have developed a PCR-based assay for the specific detection of S. saprophyticus. An arbitrarily primed PCR amplification product of 380 bp specific for S. saprophyticus was sequenced and used to design a set of S. saprophyticus-specific PCR amplification primers. The PCR assay was specific for S. saprophyticus when tested with DNA from 49 gram-positive and 31 gram-negative bacterial species. This assay was also able to amplify efficiently DNA from all 60 strains of S. saprophyticus from various origins tested. This assay was adapted for direct detection from urine samples. The sensitivity levels achieved with urine samples was 19 CFU with 30 cycles of amplification and 0.5 CFU with 40 cycles of amplification. This PCR assay for the specific detection of S. saprophyticus is simple and rapid (approximately 90 min, including the time for urine specimen preparation). PMID:10970371

  13. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    PubMed Central

    Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L

    2014-01-01

    The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection. PMID:25424447

  14. Unusually low prevalence of Mycoplasma genitalium in urine samples from infertile men and healthy controls: a prevalence study

    PubMed Central

    Plecko, Vanda; Zele-Starcevic, Lidija; Tripkovic, Vesna; Skerlev, Mihael; Ljubojevic, Suzana; Plesko, Sanja; Marekovic, Ivana; Jensen, Jorgen Skov

    2014-01-01

    Objective To detect Mycoplasma genitalium in urine samples of infertile men and men without any signs of infection in order to investigate whether M. genitalium and other genital mycoplasmas (Mycoplasma hominis and Ureaplasma spp) are found more often in urine samples of infertile men than in asymptomatic controls and to determine resistance to macrolides. Methods The study included first void urine samples taken from 145 infertile men and 49 men with no symptoms of urethritis. M. genitalium, Chlamydia trachomatis and Neisseria gonorrhoeae were detected by commercial PCR. Trichomonas vaginalis was detected by microscopy and culture. M. hominis and Ureaplasma spp were detected by culture. M. genitalium was detected by in-house conventional and real-time PCR. Results Two M. genitalium positive samples were found among samples obtained from infertile men. All asymptomatic men were M. genitalium negative. Macrolide resistance was not found in either of the two positive samples. Conclusions In comparison with reported data, an unusually low prevalence of M. genitalium was found in infertile men. The reasons for this unexpected result are not known; possibly, local demographic and social characteristics of the population influenced the result. Further studies to investigate M. genitalium in infertile and other groups of patients are needed. PMID:25157184

  15. Speciation analysis of selenium in plankton, Brazil nut and human urine samples by HPLC-ICP-MS.

    PubMed

    da Silva, Elidiane Gomes; Mataveli, Lidiane Raquel Verola; Arruda, Marco Aurélio Zezzi

    2013-06-15

    The HPLC (anion exchange)-ICP-MS technique was used for the identification (based on retention time of standards) and determination of four selenium species (selenite, selenate, selenomethionine and selenocystine) in plankton (BCR-414), Brazil nuts and urine samples. A recovery of 91% was attained for certified reference materials (BCR-414). Se(IV) was the predominant species in plankton, with the highest selenium concentration in the extract. The Brazil nuts showed only the organic species selenomethionine and selenocystine after water extraction, but after simulated gastrointestinal digestion, only selenomethionine was found as bioaccessible, corresponding to 74% of the total selenium (54.8±4.6 μg g(-1)). Analyses of the urine samples suggested the presence of selenocystine, and significant differences were observed between samples from men and women in terms of the concentration of this species after consumption of Brazil nuts (1 nut per day during 15 days). PMID:23618175

  16. PBG urine test

    MedlinePlus

    ... tested in the lab. This is called a random urine sample. If needed, your health care provider ... For a random urine sample, a negative test result is considered normal. If the test is done on a 24-hour ...

  17. Determination of Atto- to Femtogram Levels of Americium and Curium Isotopes in Large-Volume Urine Samples by Compact Accelerator Mass Spectrometry.

    PubMed

    Dai, Xiongxin; Christl, Marcus; Kramer-Tremblay, Sheila; Synal, Hans-Arno

    2016-03-01

    Ultralow level analysis of actinides in urine samples may be required for dose assessment in the event of internal exposures to these radionuclides at nuclear facilities and nuclear power plants. A new bioassay method for analysis of sub-femtogram levels of Am and Cm in large-volume urine samples was developed. Americium and curium were co-precipitated with hydrous titanium oxide from the urine matrix and purified by column chromatography separation. After target preparation using mixed titanium/iron oxides, the final sample was measured by compact accelerator mass spectrometry. Urine samples spiked with known quantities of Am and Cm isotopes in the range of attogram to femtogram levels were measured for method evaluation. The results are in good agreement with the expected values, demonstrating the feasibility of compact accelerator mass spectrometry (AMS) for the determination of minor actinides at the levels of attogram/liter in urine samples to meet stringent sensitivity requirements for internal dosimetry assessment. PMID:26822907

  18. Solvent-assisted dispersive solid-phase extraction: A sample preparation method for trace detection of diazinon in urine and environmental water samples.

    PubMed

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-09-01

    In this research, a sample preparation method termed solvent-assisted dispersive solid-phase extraction (SA-DSPE) was applied. The used sample preparation method was based on the dispersion of the sorbent into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was received by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the diazinon, the cloudy solution was centrifuged and diazinon in the sediment phase dissolved in ethanol and determined by gas chromatography-flame ionization detector. Under the optimized conditions (pH of solution=7.0, Sorbent: benzophenone, 2%, Disperser solvent: ethanol, 500μL, Centrifuge: centrifuged at 4000rpm for 3min), the method detection limit for diazinon was 0.2, 0.3, 0.3 and 0.3μgL(-1) for distilled water, lake water, waste water and urine sample, respectively. Furthermore, the pre-concentration factor was 363.8, 356.1, 360.7 and 353.38 in distilled water, waste water, lake water and urine sample, respectively. SA-DSPE was successfully used for trace monitoring of diazinon in urine, lake and waste water samples. PMID:27495366

  19. Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples

    NASA Astrophysics Data System (ADS)

    Salem, A. A.; Barsoum, B. N.; Izake, E. L.

    2004-03-01

    New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 μg ml -1 with detection limits of 1.27, 0.08 and 0.13 μg ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 μg ml -1 with detection limits of 7.13, 5.67 and 16.47 ng ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.

  20. Molecular identification of multi drug resistant bacteria from urinary tract infected urine samples.

    PubMed

    Kumar, M S; Das, A P

    2016-09-01

    Urinary tract infections (UTIs) are of great concern in both developing and developed countries all over the world. Even though the infections are more common in women and children, they are at a considerable rate in men and of all ages. The uropathogens causing the infections are spread through various routes. The treatment generally recommended by the physicians is antibiotic usage. But, most of the uropathogens have evolved antibiotic resistance mechanisms. This makes the present situation hectic in control and prevention of UTIs. The present study aims to illustrate the multidrug resistance patterns among isolated bacterial strains from infected urine samples in Odisha state, India. Four bacterial strains were isolated and identified as Proteus sp. SK3, Pseudomonas sp. ADMK77, Proteus sp. BLKB2 and Enterobacter hormaechei strain CW-3 by 16S rRNA gene sequencing. Phylogenetc analysis indicated the strains belong to three various genera namely, Proteus, Pseudomonas and Enterobacter. The evolutionary timeline of the bacteria was studied by constructing phylogenetic trees by Neighborhood Joining method. The presence of ESBL gene and biofilm forming capability were studied for the four strains. Antibiotic susceptibility patterns of the isolates were studied toward the commonly recommended antibiotics. Both the Proteus strains were found commonly susceptible to aminoglycoside and sulphonamide groups. Pseudomonas strain was found to be susceptible to cephems, aminoglycosides and fluoroquinolones. Enterobacter sp was found to be resistant to almost all antibiotic groups and susceptible to only sulphonamides group. The antibiotic susceptibility patterns of the bacteria help in choosing the empirical antibiotic treatment for UTI. PMID:27354209

  1. Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples

    PubMed Central

    Charehsaz, Mohammad; Gürbay, Aylin; Aydin, Ahmet; Şahin, Gönül

    2014-01-01

    In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separation was achieved on a C18 column by using 60:40 methanol:water as mobile phase under isocratic conditions at a flow rate of 0.75 mL/min with UV detection at 280 nm in HPLC method. UV spectrophotometric analysis was performed at 275 nm. The results of HPLC analysis were as follows: the limit of quantification: 1.1 µg/mL for urine, 1.9 µg/mL for saliva, 3.1 µg/mL for plasma; recovery: 94.85% for plasma, 100.45% for saliva, 101.39% for urine; intra-day precision: 0.22–2.33%, inter-day precision: 3.17-13.12%. Spectrophotometric analysis results were as follows: the limit of quantitation: 5.23 µg/mL for plasma, 8.7 µg/mL for urine; recovery: 98.27% for plasma, 95.25% for urine; intra-day precision: 2.37 – 3.00%, inter-day precision: 5.43-7.91%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of theophylline in biological samples. Also spectrophotometric analysis can be used where it can be applicable. PMID:25237338

  2. Determination of uranium in urine samples of fuel element fabrication workers by beta-delayed neutron counting

    NASA Astrophysics Data System (ADS)

    Gabelmann, H.; Lerch, M.; Kratz, K.-L.; Rudolph, W.

    1984-06-01

    Within the health physics examination of fuel element fabrication workers, the control of uranium incorporation is of importance. This is commonly performed by the determination of the alpha activity concentration of uranium excreted in the urine. However, since the chemical separation procedure and the preparation of alpha-counting samples are complicated and time-consuming, this method may imply restrictions on the routine control of large numbers of persons. Therefore, we have investigated the applicability of measuring the beta-delayed neutrons from thermal neutron induced fission of the 235U in the urine samples. The uranium was separated by coprecipitation with Fe(OH) 3 from the urine samples and irradiated in a rabbit system of the Mainz TRIGA reactor. The neutrons were counted with a 3He long counter. The detection limit of 0.3 to 0.9 pCi 1 -1 is comparable to that of alpha spectrometry, but the time required for one sample, from preparation to data evaluation is less than 25 min.

  3. Detection and sequencing of West Nile virus RNA from human urine and serum samples during the 2014 seasonal period.

    PubMed

    Nagy, Anna; Bán, Enikő; Nagy, Orsolya; Ferenczi, Emőke; Farkas, Ágnes; Bányai, Krisztián; Farkas, Szilvia; Takács, Mária

    2016-07-01

    West Nile virus, a widely distributed mosquito-borne flavivirus, is responsible for numerous animal and human infections in Europe, Africa and the Americas. In Hungary, the average number of human infections falls between 10 and 20 cases each year. The severity of clinically manifesting infections varies widely from the milder form of West Nile fever to West Nile neuroinvasive disease (WNND). In routine laboratory diagnosis of human West Nile virus infections, serological methods are mainly applied due to the limited duration of viremia. However, recent studies suggest that detection of West Nile virus RNA in urine samples may be useful as a molecular diagnostic test for these infections. The Hungarian National Reference Laboratory for Viral Zoonoses serologically confirmed eleven acute human infections during the 2014 seasonal period. In three patients with neurological symptoms, viral RNA was detected from both urine and serum specimens, albeit for a longer period and in higher copy numbers with urine. Phylogenetic analysis of the NS3 genomic region of three strains and the complete genome of one selected strain demonstrated that all three patients had lineage-2 West Nile virus infections. Our findings reaffirm the utility of viral RNA detection in urine as a molecular diagnostic procedure for diagnosis of West Nile virus infections. PMID:27038827

  4. Feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization mass spectrometry in analyzing anabolic steroids in urine samples.

    PubMed

    Ahonen, Linda L; Haapala, Markus; Saarela, Ville; Franssila, Sami; Kotiaho, Tapio; Kostiainen, Risto

    2010-04-15

    We examined the feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization tandem mass spectrometry (capLC/microAPPI-MS/MS) for the analysis of anabolic steroids in human urine. The urine samples were pretreated by enzymatic hydrolysis (with beta-glucuronidase from Helix pomatia), and the compounds were liquid-liquid extracted with diethyl ether. After separation the compounds were vaporized by microchip APPI, photoionized by a 10 eV krypton discharge lamp, and detected by selected reaction monitoring. The capLC/microAPPI-MS/MS method showed good sensitivity with detection limits at the level of 1.0 ng mL(-1), good linearity with correlation coefficients between 0.9954 and 0.9990, and good repeatability with relative standard deviations below 10%. These results demonstrate that microchip APPI combined with capLC/MS/MS provides a new potential method for analyzing non-polar and neutral compounds in biological samples. PMID:20209666

  5. Immunoelectrophoresis - urine

    MedlinePlus

    Immunoglobulin electrophoresis - urine; Gamma globulin electrophoresis - urine; Urine immunoglobulin electrophoresis; IEP - urine ... is used to measure the amounts of various immunoglobulins in urine. Most often, it is done after ...

  6. First attempt to monitor luteinizing hormone and reproductive steroids in urine samples of the Amazonian manatee (Trichechus inunguis).

    PubMed

    Amaral, Rodrigo S; Rosas, Fernando C W; Graham, Laura H; da Silva, Vera M F; Oliveira, Claudio A

    2014-12-01

    The aims of this study were to validate an enzyme immunoassay (EIA) for the measurement of luteinizing hormone (LH) in urine samples of Amazonian manatees (Trichechus inunguis; Mammalia: Sirenia) and to monitor urinary LH and reproductive steroids during the ovarian cycle in this species. Urine samples were collected from two captive males following a hormonal challenge with a gonadotropin-releasing hormone (GnRH) analogue. The urinary LH results from hormonal challenge were compared with urinary androgens for the purpose of EIA validation. Furthermore, urine samples were collected daily, over a 12-wk period, from two captive adult females, for 2 consecutive yr. The urinary LH pattern from females was compared with the patterns of urinary progestagens and estrogen conjugates throughout the ovarian cycle. An LH peak was observed in both male Amazonian manatees after the hormonal challenge, occurring prior to or together with peak androgen levels. In the females, the ovarian cycle ranged from 40 to 48 days (mean of 43.7 days). Two distinct peaks of estrogen conjugates were observed across all cycles analyzed, and the urinary LH peaks observed were accompanied by peaks of urinary estrogen conjugates. The EIA was validated as a method for the quantification of urinary LH from Amazonian manatees, as it was able to detect variations in the levels of LH in urine samples. These results suggest that T. inunguis exhibits a peculiar hormonal pattern during the ovarian cycle. Therefore, further studies are desirable and necessary to clarify the relationship between this hormonal pattern and morphological changes, as well as mating behavior, in Amazonian manatee. PMID:25632672

  7. A Modified Catheterization Procedure to Reduce Bladder Damage when Collecting Urine Samples from Holstein Cows

    PubMed Central

    TAMURA, Tetsuo; NAKAMURA, Hiroshi; SATO, Say; SEKI, Makoto; NISHIKI, Hideto

    2014-01-01

    ABSTRACT This study proposed a modified procedure, using a small balloon catheter (SB catheter, 45 ml), for reducing bladder damage in cows. Holstein cows and the following catheters were prepared: smaller balloon catheter (XSB catheter; 30 ml), SB catheter and standard balloon catheter (NB catheter; 70 ml, as the commonly used, standard size). In experiment 1, each cow was catheterized. The occurrence of catheter-associated hematuria (greater than 50 RBC/HPF) was lower in the SB catheter group (0.0%, n=7) than in the NB catheter group (71.4%, n=7; P<0.05). In experiment 2, general veterinary parameters, urine pH, body temperature and blood values in cows were not affected before or after insertion of SB catheters (n=6). The incidence of urinary tract infection (UTI) was 3.0% per catheterized day (n=22). In experiment 3, feeding profiles, daily excretion of urinary nitrogen (P<0.05) and rate from nitrogen intake in urine (P<0.01), were higher with use of the SB catheter (n=13) than with the use of the vulva urine cup (n=18), indicating that using the SB catheter can provide accurate nutritional data. From this study, we concluded that when using an SB catheter, the following results occur; reduction in bladder damage without any veterinary risks and accuracy in regard to feeding parameters, suggesting this modified procedure using an SB catheter is a useful means of daily urine collection. PMID:24561376

  8. Development of a gas chromatographic test for the quantitation of the biomarker 2-butoxyacetic acid in urine samples.

    PubMed

    B'Hymer, C

    2007-08-01

    An accurate and precise method is developed and evaluated for the detection and quantitation of 2-butoxyacetic acid (2-BAA), a metabolite and biomarker for human exposure to 2-butoxyethanol. The solvent 2-butoxyethanol (2-BE) is extensively used in various industrial and domestic applications, and it is a health concern owing to its toxicity. Sample preparation consists of liquid-liquid extraction (LLE) of urine, then esterification of 2-BAA to produce the ethyl ester analog. The gas chromatographic conditions utilize a dimethyl polysiloxane phase (HP-1) capillary column and a mass spectrometer (MS) for detection of the analyte. Validation of this method includes a recovery study using fortified urine samples, which demonstrated good accuracy and precision; recovery varied between 100% and 102% of theory, with relative standard deviations of replicate samples at 2.8% and less. The detection limit of this method ranges from 0.005 to 0.015 microg/mL equivalent level of 2-BAA in urine. PMID:17725869

  9. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--HUMAN BIOLOGICAL MARKERS:BLOOD AND URINE SAMPLE COLLECTION AND ANALYSES (EOHSI-AP-209-040)

    EPA Science Inventory

    This procedure describes the process for collecting and analyzing blood and urine samples. The presence of chemical contaminants in biological specimens such as blood, urine, and hair represent a measure of the internal dose or body burden for a given individual derived from the ...

  10. Evaluation of biomarkers in plasma, blood, and urine samples from coke oven workers: significance of exposure to polycyclic aromatic hydrocarbons.

    PubMed Central

    Ovrebø, S; Haugen, A; Farmer, P B; Anderson, D

    1995-01-01

    OBJECTIVE--The aim was to assess the significance of two biomarkers; antibody to benzo(a)pyrene DNA adducts and concentration of hydroxyethylvaline haemoglobin adducts in samples from a well studied group of coke oven workers. As a measure of exposure we have used 1-hydroxypyrene in urine. METHODS--Urine and blood samples were collected from coke oven workers and a control group. Samples from coke oven plant workers were collected in January and June. 1-Hydroxypyrene was measured in urine by high performance liquid chromatography (HPLC), antibodies to benzo(a)pyrene DNA adducts were measured by ELISA and hydroxyethylvaline haemoglobin adducts were measured by gas chromatography-mass spectrometry (GC-MS). RESULTS--Mean urinary 1-hydroxypyrene in samples from coke oven workers varied from 1.11 to 5.53 umol/mol creatinine and 0.14 umol/mol creatinine in the control group. Workers at the top side had the highest values of urinary 1-hydroxypyrene. Antibody to benzo(a)pyrene DNA adducts did not correlate with either 1-hydroxypyrene nor length of work at the coke oven plant. But antibody concentration in samples collected in January was predictive of the concentration in samples collected in June. A small non-significant increase in hydroxyethylvaline haemoglobin adducts was found in samples from coke oven workers relative to the control group when comparing smokers and nonsmokers separately. CONCLUSION--1-Hydroxypyrene correlates well with exposure groups based on job description. Antibodies to benzo(a)-pyrene DNA adducts was related to people and not exposure. Work at a coke oven plant might lead to increased hydroxyethylvaline haemoglobin adducts. PMID:8535495

  11. Sample clean-up by sol-gel immunoaffinity chromatography for the determination of bisphenol A in food and urine.

    PubMed

    Cichna-Markl, Margit

    2012-02-01

    Bisphenol A (2,2-bis(4-hydroxyphenyl)propane, BPA) is an industrial chemical mainly used as a monomer in the synthesis of polycarbonates and epoxy resins. BPA has been shown to elicit estrogenic effects via binding to the nuclear estrogen receptors α and β. Food is considered as the major source of BPA exposure for the general human population. When incorporated into the body, BPA is metabolised in the liver, mainly to BPA glucuronide, and excreted via the urine. The present paper presents analytical methods for the determination of BPA concentrations in foodstuffs and the determination of free and total (free plus conjugated) BPA in urine samples. The paper provides protocols for the preparation and operation of sol-gel immunoaffinity columns and their application to remove interfering matrix compounds and to enrich BPA. In addition, the paper points out major sources of systematic errors in BPA analysis and describes how they can be avoided. PMID:21871961

  12. Worker exposures to triclopyr: risk assessment through measurements in urine samples.

    PubMed

    Gosselin, Nathalie H; Brunet, Robert C; Carrier, Gaétan; Dosso, Amssétou

    2005-07-01

    In the province of Quebec (Canada), the phytocide Garlon 4, whose active ingredient is triclopyr, is often used to prevent trees from reaching electrical conductors. The object of this paper is to assess the potential health risks in workers coming into contact with Garlon 4. Ten workers collected their urine during the 22 h following the beginning of a work shift. Measured urinary amounts of triclopyr varied between 1 and 13 mg. The absorbed daily doses were estimated from the amounts of triclopyr in urine through the use of a kinetic model that links the rates of triclopyr elimination to absorbed doses. These estimated doses were compared with the no-observed-effect level (NOEL) observed in rats: 5 mg per kg of body weight. The upper-bound estimations of the worker's daily absorbed doses were found to be 13.3% or less of the rat NOEL. PMID:15703284

  13. The preservation of urine samples for determination of renal stone risk factors

    NASA Technical Reports Server (NTRS)

    Nicar, M. J.; Hsu, M. C.; Johnson, T.; Pak, C. Y.

    1987-01-01

    A preservation technique for urine specimens before determination of stone risk factors was evaluated. The purpose of these experiments was to prove the effectiveness of the preservatives used to prevent changes in the concentrations of those constituents measured. Measured concentrations in fresh specimens were compared with those in the same specimens after storage with the preservatives. Refrigeration at 4 degrees C up to five days was appropriate in a laboratory setting, as no significant changes in urinary concentrations occurred. Refrigeration, however, did not offer a convenient method for shipping. Chemical preservation was found to be an effective alternative to refrigeration. Thymol prevented changes in concentration of pH, citrate, uric acid, sulfate, sodium, potassium, and cyclic AMP, while a mixture of hydrochloric (HCl) acid and boric acid prevented changes in calcium, magnesium, phosphorus, oxalate, ammonium, and creatinine. Thus, the addition of thymol or HCl/boric acid to urine specimens will prevent significant changes in the concentrations of stone risk factors.

  14. Structural Elucidation of a Carnosine-Acrolein Adduct and its Quantification in Human Urine Samples

    PubMed Central

    Bispo, Vanderson S.; de Arruda Campos, Ivan P.; Di Mascio, Paolo; Medeiros, Marisa H. G.

    2016-01-01

    Aldehydes accumulate in inflammation, during myocardial infarction and have been associated with pain symptoms. One pathway of aldehyde detoxification is the conjugation with carnosine. A 3-methylpyridinium carnosine adduct from the reaction of carnosine and acrolein was characterized using extensive spectroscopic measurements. The adduct with urinary concentrations of 1.82 ± 0.68 nmol/mg of creatinine is one of the most abundant acrolein metabolites in urine and opens promising therapeutic strategies for carnosine. PMID:26783107

  15. Structural Elucidation of a Carnosine-Acrolein Adduct and its Quantification in Human Urine Samples.

    PubMed

    Bispo, Vanderson S; de Arruda Campos, Ivan P; Di Mascio, Paolo; Medeiros, Marisa H G

    2016-01-01

    Aldehydes accumulate in inflammation, during myocardial infarction and have been associated with pain symptoms. One pathway of aldehyde detoxification is the conjugation with carnosine. A 3-methylpyridinium carnosine adduct from the reaction of carnosine and acrolein was characterized using extensive spectroscopic measurements. The adduct with urinary concentrations of 1.82 ± 0.68 nmol/mg of creatinine is one of the most abundant acrolein metabolites in urine and opens promising therapeutic strategies for carnosine. PMID:26783107

  16. RBC urine test

    MedlinePlus

    Red blood cells in urine; Hematuria test; Urine - red blood cells ... A normal result is 4 red blood cells per high power field (RBC/HPF) or less when the sample is examined under a microscope. The example above ...

  17. Urea nitrogen urine test

    MedlinePlus

    A 24-hour urine sample is often needed. You will need to collect your urine over 24 hours . Your health care provider will tell you how to do this. Follow instructions exactly to ensure accurate results.

  18. Cytology exam of urine

    MedlinePlus

    ... The urine sample can also be collected during cystoscopy . During this procedure, your provider uses a thin, ... discomfort with a clean catch urine specimen. During cystoscopy, there may be slight discomfort when the scope ...

  19. A novel stacking method of repetitive large volume sample injection and sweeping MEKC for determination of androgenic steroids in urine.

    PubMed

    Wang, Chun-Chi; Chen, Jia-Ling; Chen, Yen-Ling; Cheng, Hui-Ling; Wu, Shou-Mei

    2012-09-26

    In this research, a novel stacking capillary electrophoresis method, repetitive large volume sample injection and sweeping MEKC (rLVSI-sweeping MEKC) were developed to analyze the presence of three androgenic steroids considered as sport doping drugs, testosterone (T), epitestosterone (E) and epitestosterone glucuronide (EG) in urine. This method provides better sensitivity enhancement than the traditional large volume sample stacking-sweeping strategies due to sensitivity enhancement by repetitive injections. This multiple sampling method enhances sensitivity of monitoring of urine samples by UV detection (254 nm). Firstly, the phosphate buffer was filled into an uncoated fused silica capillary and the samples were injected into the capillary at 10 psi for 20s, and then stacked at -10 kV for 1 min using phosphate buffer containing SDS. The above injecting and stacking steps were repeated five times. Finally, separation was performed at -20 kV, using phosphate buffer containing methanol, SDS and (2-hydroxypropyl)-β-cyclodextrin. Method validation showed that calibration plots were linear (r≥0.997) over a range of 5-200 ng mL(-1) for T, 20-200 ng mL(-1) for E and 0.5-500 ng mL(-1) for EG. The limits of detection were 1.0 ng mL(-1) for T, 5.0 ng mL(-1) for E and 200.0 pg mL(-1) for EG. When evaluating precision and accuracy, values of RSD and RE in intra-day (n=3) and inter-day (n=5) analysis were found to be less than 10.0%. Compared with the simple LVSS-sweeping, which is also a stacking strategy, this method further improves sensitivity up to 25 folds (~2500 folds with MEKC without preconcentration). This method was applied to monitor 10 athletes' urine, and did not detect any analyte. The novel stacking method was feasible for monitoring of doping by sportsmen. PMID:22935380

  20. Heavy Metals and Trace Elements in Hair and Urine of a Sample of Arab Children with Autistic Spectrum Disorder

    PubMed Central

    BLAUROCK-BUSCH, Eleonor; AMIN, Omnia R.; RABAH, Thanaa

    2011-01-01

    or suspected by their parents as being autistic. All children were attendants to the Child Psychiatric Clinic in Erfan Psychiatric Hospital in Jeddah, KSA. Samples were collected during the period of June 2006 to March 2008. A control group of 25 children without any psychiatric or medical disorders was age-matched and sex-matched. All parents signed informed consent forms. All autistic children were subjected to a full clinical child psychiatric sheet for the diagnosis of autism spectrum disorder and exclusion of other psychiatric disorders according to the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition (DSM IV). The severity of autistic symptomatology was measured by the Childhood Autism Rating Scale (CARS) and Autism Behavior Checklist (ABC) using the Arabic versions. Both groups were subjected to the Questionnaire on Exposure to Heavy Metals, Physical Symptoms, and Child Development. Hair and baseline urine samples (i.e. unprovoked urine) were taken from both groups and sent to the German clinical and environmental laboratory Micro Trace Minerals Gmbh, for the detection of heavy metals and trace elements levels where metal testing was performed via ICP-MS spectroscopy utilizing cell technique. Results: By comparing the ASD Group to the Control Group, we found a statistically significant difference in the mean hair levels of arsenic, cadmium, barium, cerium and lead (p=0.01, 0.03, 0.003, 0.003, and 0.03 respectively), and in the mean hair levels of magnesium and zinc (p=0.001 and 0.003 respectively). There were also statistically significant differences in the mean urine levels of aluminum, barium, cerium, mercury, and lead (p=0.004, 002, 0.014, 0.006 and 0.004 respectively), and in the mean urine levels of copper and germanium (p=0.049 and 0.02 respectively). An agreement was found in both specimen (hair and urine) for barium and lead. The statistically significant differences in mean hair levels of arsenic, cadmium, and cerium were not

  1. Pattern of Antibiotic Resistance Among Community Derived Isolates of Enterobacteriaceae Using Urine Sample: A Study From Northern India

    PubMed Central

    Lohiya, Ayush; Kapil, Arti; Gupta, Sanjeev Kumar; Misra, Puneet; Rai, Sanjay K.

    2015-01-01

    Background Despite world-wide evidence of increased antibiotic resistance, there is scarce data on antibiotic resistance in community settings. One of the reason being difficulty in collection of biological specimen (traditionally stool) in community from apparently healthy individuals. Hence, finding an alternative specimen that is easier to obtain in a community setting or in large scale surveys for the purpose, is crucial. We conducted this study to explore the feasibility of using urine samples for deriving community based estimates of antibiotic resistance and to estimate the magnitude of resistance among urinary isolates of Escherichia coli and Klebsiella pneumonia against multiple antibiotics in apparently healthy individuals residing in a rural community of Haryana, North India. Materials and Methods Eligible individuals were apparently healthy, aged 18 years or older. Using the health management information system (HMIS) of Ballabgarh Health Demographic Surveillance System (HDSS), sampling frame was prepared. Potential individuals were identified using simple random sampling. Random urine sample was collected in a sterile container and transported to laboratory under ambient condition. Species identification and antibiotic susceptibility testing for Enterobacteriaceae was done using Clinical Laboratory and Standards Institute (CLSI) 2012 guidelines. Multi-drug resistant (MDR) Enterobacteriaceae, Extended Spectrum Beta Lactamase (ESBL) producing Enterobacteriaceae, and Carbapenem producing Enterobacteriaceae (CRE) were identified from the urine samples. Results A total of 433 individuals participated in the study (non-response rate – 13.4%), out of which 58 (13.4%) were positive for Enterobacteriaceae, 8.1% for E. coli and 5.3% for K. pneumoniae. Resistance against penicillin (amoxicillin/ampicillin) for E. coli and K. pneumoniae was 62.8% and 100.0% respectively. Isolates resistant to co-trimoxazole were 5.7% and 0.0% respectively. None of the isolates

  2. Analysis of anabolic androgenic steroids in urine by full-capillary sample injection combined with a sweeping CE stacking method.

    PubMed

    Wang, Chun-Chi; Cheng, Shu-Fang; Cheng, Hui-Ling; Chen, Yen-Ling

    2013-02-01

    This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid-liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at -20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r≥0.990) over a range of 50-1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n=3) and inter-day (n=5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N=5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping. PMID:23263519

  3. Anaerococcus urinomassiliensis sp. nov., isolated from a urine sample of a 17-year-old boy affected by autoimmune hepatitis and membranoproliferative glomerulonephritis.

    PubMed

    Morand, A; Cornu, F; Tsimaratos, M; Lagier, J-C; Cadoret, F; Fournier, P-E; Raoult, D

    2016-09-01

    We report the main characteristics of 'Anaerococcus urinomassiliensis' strain FC4(T) (CSURP2143) that was isolated from a urine sample of a 17-year-old boy affected by autoimmune hepatitis and membranoproliferative glomerulonephritis. PMID:27408746

  4. Magnetic nano graphene oxide as solid phase extraction adsorbent coupled with liquid chromatography to determine pseudoephedrine in urine samples.

    PubMed

    Taghvimi, Arezou; Hamishehkar, Hamed; Ebrahimi, Mahmoud

    2016-01-15

    This paper reports on a method based on magnetic solid phase extraction (MSPE) for the determination of pseudoephedrine. Magnetic nanographene oxide (MNGO) was applied as a new adsorbent for the extraction of pseudoephedrine from urine samples. Synthesis of MNGO was characterized by Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), powder X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). The main factors influencing extraction efficiency, including the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, ionic strength of extraction medium, and agitation rate, were investigated and optimized. Under optimized extraction conditions, a good linearity was observed in the range of 100-2000ng/mL with a correlation coefficient of 0.9908 (r(2)). Limit of detection (LOD) and limit of quantification (LOQ) were 25 and 82.7ng/mL, respectively. Inter-day and intra-day precision and accuracy were 6.01 and 0.34 (%), and 8.70 and 0.29 (%), respectively. The method was applied for the determination of pseudoephedrine in urine samples of volunteers receiving pseudoephedrine with the recovery of 96.42. It was concluded that the proposed method can be applied in diagnostic clinics. PMID:26708626

  5. Porphyrins - urine

    MedlinePlus

    ... results may be due to: Liver cancer Hepatitis Lead poisoning Porphyria (several types) Alternative Names Urine uroporphyrin; Urine ... More Delta-ALA urine test Enzyme Hemoglobin Hepatitis Lead poisoning Liver cancer - hepatocellular carcinoma PBG urine test Porphyria ...

  6. Comparative Evaluation of Inoculation of Urine Samples with the Copan WASP and BD Kiestra InoqulA Instruments.

    PubMed

    Iversen, Jesper; Stendal, Gitta; Gerdes, Cecilie M; Meyer, Christian H; Andersen, Christian Østergaard; Frimodt-Møller, Niels

    2016-02-01

    This study evaluated the quantitative results from and quality of the inoculation patterns of urine specimens produced by two automated instruments, the Copan WASP and the BD InoqulA. Five hundred twenty-six urine samples submitted in 10-ml canisters containing boric acid were processed within 30 min on an InoqulA instrument plating 10 μl of specimen, and on two WASP instruments, one plating 1 μl of specimen (WASP-1), and the second plating 10 μl of WASP (WASP-10). All samples were incubated, analyzed, and digitally imaged using the BD Kiestra total lab automation system. The results were evaluated using a quantitative protocol and assessed for the presence or absence of ≥5 distinct colonies. Separate studies were conducted using quality control (QC) organisms to determine the relative accuracy of WASP-1, WASP-10, and InoqulA instruments compared to the results obtained with a calibrated pipette. The results with QC organisms were calculated as the ratios of the counts of the automated instruments divided by the counts for the calibrated pipette (the gold standard method). The ratios for the InoqulA instrument were closest to 1.0, with the smallest standard deviations indicating that compared to a calibrated pipette, the InoqulA results were more accurate than those with the WASP instrument. For clinical samples, the WASP instruments produced higher colony counts and more commensals than the InoqulA instrument, with differences most notable for WASP-1. The InoqulA instrument was significantly better at dispersing organisms with counts of ≥10(5) bacteria/ml of urine than were the WASP-1 and WASP-10 instruments (P < 0.05). Our results suggest that the InoqulA quantitative results are more accurate than the WASP results, and, moreover, the number of isolated colonies produced by the InoqulA instrument was significantly greater than that produced by the WASP instrument. PMID:26607980

  7. A simple and rapid ESI-LC-MS/MS method for simultaneous screening of doping agents in urine samples

    PubMed Central

    Reddy, I. Madhusudhana; Beotra, Alka; Jain, S.; Ahi, S.

    2009-01-01

    Objective: The use of performance enhancing substances is banned in sports by the World Anti-Doping Agency (WADA). Though most prohibited substances can be detected by GC/MS, inclusion of corticosteroids and designer drugs has made it essential to detect these critical doping agents on LC/MS/MS due to their better separation and detection. Materials and Methods: A common extraction procedure for the isolation of acidic, basic and neutral drugs from urine samples was developed. A total of 28 doping drugs were analyzed on API 3200 Triple quadrupole mass spectrometer using C18 column in atmospheric pressure electrospray ionization. The mobile phase composition was a mixture of 1% formic acid and acetonitrile with gradient time period. Results: The method developed was very sensitive for detection of 28 doping agents. The linearity was performed for each drug and the total recovery percentage ranged from 57 to 114. Limit of detection is found to be 0.5 ng/ml for carboxy finasteride and 1-5 ng/ml for other drugs. The method was successfully used to detect positive urine samples of 3-OH-stanozolol, methyl phenidate, mesocarb, clomiphene metabolite and carboxy finasteride. Conclusion: The method developed based on controlled pH extraction method and HPLC-mass spectrometry analysis allowed better identification and confirmation of glucocorticosteroids and a few other drugs in different categories. The validated method has been used successfully for testing of 1000 In-competition samples. The method helped in detection of chemically and pharmacologically different banned drugs in urine in a single short run at a minimum required performance limit set by WADA. PMID:20336223

  8. Comparative Evaluation of Inoculation of Urine Samples with the Copan WASP and BD Kiestra InoqulA Instruments

    PubMed Central

    Iversen, Jesper; Stendal, Gitta; Gerdes, Cecilie M.; Meyer, Christian H.; Andersen, Christian Østergaard

    2015-01-01

    This study evaluated the quantitative results from and quality of the inoculation patterns of urine specimens produced by two automated instruments, the Copan WASP and the BD InoqulA. Five hundred twenty-six urine samples submitted in 10-ml canisters containing boric acid were processed within 30 min on an InoqulA instrument plating 10 μl of specimen, and on two WASP instruments, one plating 1 μl of specimen (WASP-1), and the second plating 10 μl of WASP (WASP-10). All samples were incubated, analyzed, and digitally imaged using the BD Kiestra total lab automation system. The results were evaluated using a quantitative protocol and assessed for the presence or absence of ≥5 distinct colonies. Separate studies were conducted using quality control (QC) organisms to determine the relative accuracy of WASP-1, WASP-10, and InoqulA instruments compared to the results obtained with a calibrated pipette. The results with QC organisms were calculated as the ratios of the counts of the automated instruments divided by the counts for the calibrated pipette (the gold standard method). The ratios for the InoqulA instrument were closest to 1.0, with the smallest standard deviations indicating that compared to a calibrated pipette, the InoqulA results were more accurate than those with the WASP instrument. For clinical samples, the WASP instruments produced higher colony counts and more commensals than the InoqulA instrument, with differences most notable for WASP-1. The InoqulA instrument was significantly better at dispersing organisms with counts of ≥105 bacteria/ml of urine than were the WASP-1 and WASP-10 instruments (P < 0.05). Our results suggest that the InoqulA quantitative results are more accurate than the WASP results, and, moreover, the number of isolated colonies produced by the InoqulA instrument was significantly greater than that produced by the WASP instrument. PMID:26607980

  9. Pseudo-homogeneous immunoextraction of epitestosterone from human urine samples based on gold-coated magnetic nanoparticles.

    PubMed

    Qiu, Shuang; Xu, Li; Cui, Yi-Ran; Deng, Qin-Pei; Wang, Wei; Chen, Hong-Xu; Zhang, Xin-Xiang

    2010-05-15

    A pseudo-homogeneous immunoextraction method based on gold-coated magnetic nanoparticles (MNPs) for the specific extraction and quantitative analysis of epitestosterone (17alpha-hydroxy-4-androsten-3-one, abbreviated as "ET") from human urine samples by high-performance liquid chromatography (HPLC) has been developed. Half-IgG of anti-ET monoclonal antibodies were covalently immobilized onto (Fe(3)O(4))(core)-Au(shell) (Fe(3)O(4)@Au) MNPs. An external magnetic field was applied to collect the MNPs which were then rinsed with distilled water followed by elution with absolute methanol to obtain ET as the analyte. The obtained extraction solution was analyzed by HPLC with UV detection (244nm) within 12min. The standard calibration curve for ET showed good linearity in the range of 20-200ngmL(-1) in phosphate-buffered saline (PBS) solutions with acceptable accuracy and precision. Limit of detection for ET was 0.06ngmL(-1) due to an enrichment factor of 100-fold was achieved. The results obtained by the present method for spiked human urine samples were in agreement with those from indirect competitive enzyme-linked immunoadsorbent assays (ELISAs). The antibody-conjugated Fe(3)O(4)@Au MNPs are novel materials for immunoaffinity extraction. Compared with the conventional technique using immunoaffinity column, the method described here for sample pretreatment was fast, highly specific, and easy to operate. PMID:20298859

  10. Extractive determination of ephedrine hydrochloride and bromhexine hydrochloride in pure solutions, pharmaceutical dosage form and urine samples.

    PubMed

    Abdel-Ghani, N T; Rizk, M S; Mostafa, M

    2013-07-01

    Simple, rapid, sensitive, precise and accurate spectrophotometeric methods for the determination of ephedrine hydrochloride (E-HCl) and bromhexine hydrochloride (Br-HCl) in bulk samples, dosage form and in spiked urine samples were investigated. The methods are based on the formation of a yellow colored ion-associates due to the interaction between the examined drugs with picric acid (PA), chlorophyllin coppered trisodium salt (CLPH), alizarin red (AR) and ammonium reineckate (Rk) reagents. A buffer solution had been used and the extraction was carried out using organic solvent, the ion associates exhibit absorption maxima at 410, 410, 430 and 530 nm of (Br-HCl)with PA, CLPH, AR and Rk respectively; 410, 410, 435 and 530 of (E-HCl) with PA, CLPH, AR and Rk respectively. (E-HCl) and (Br-HCl) could be determined up to 13, 121, 120 and 160; 25, 200, 92 and 206 μg mL(-1), using PA, CLPH, AR and Rk respectively. The optimum reaction conditions for quantitative analysis were investigated. In addition, the molar absorptivity, Sandell sensitivity were determined for the investigated drug. The correlation coefficient was ≥0.995 (n=6) with a relative standard deviation (RSD) ≤1.15 for five selected concentrations of the reagents. Therefore the concentration of Br-HCl and E-HCl drugs in their pharmaceutical formulations and spiked urine samples had been determined successfully. PMID:23624039

  11. Association between aflatoxin M1 excreted in human urine samples with the consumption of milk and dairy products.

    PubMed

    Mohd Redzwan, Sabran; Rosita, Jamaluddin; Mohd Sokhini, Abdul Mutalib; Nurul Aqilah, Abdul Rahman

    2012-12-01

    This study aimed to find the association between urinary aflatoxin M(1) level and milk and dairy products consumption. Of 160 morning urine samples collected, aflatoxin M(1) was detected in 61.3 % samples (n = 98) [mean ± SD = 0.0234 ± 0.0177 ng/mL; range = 0-0.0747 ng/mL]. Of these positive samples, 67.3 % (n = 66) had levels above the limit of detection. Respondents with intake of milk and dairy products above median (67.79 g/day) had significantly high level of AFM(1) compared to those with low intake. A significant and positive association (φ = 0.286) was found between milk and dairy products consumption and urinary aflatoxin M(1) level. PMID:23052590

  12. Fabrication of a gel particle array in a microfluidic device for bioassays of protein and glucose in human urine samples.

    PubMed

    Lin, Ling; Gao, Zhaoxin; Wei, Huibin; Li, Haifang; Wang, Feng; Lin, Jin-Ming

    2011-09-01

    This paper describes a simple method for fabricating a series of poly(ethylene glycol) diacrylate (PEG-DA) hydrogel microstructures inside microfluidic channels as probe for proteins and glucose. In order to demonstrate the feasibility of this newly developed system, bovine serum albumin (BSA) was chosen as a model protein. PEG microcolumns were used for the parallel detection of multiple components. Using tetrabromophenol blue (TBPB) and the horseradish peroxidase/glucose oxidase reaction system, bovine serum albumin (BSA) and glucose in human urine were detected by color changes. The color changes for BSA within a concentration range of 1-150 μM, and glucose within a range of 50 mM-2 M could be directly distinguished by eyes or precisely identified by optical microscope. To show the practicability of the gel particle array, protein and glucose concentrations of real human urine samples were determined, resulting in a good correlation with hospital analysis. Notably, only a 5 µL sample was needed for a parallel measurement of both analytes. Conveniently, no special readout equipment or power source was required during the diagnosis process, which is promising for an application in rapid point-of-care diagnosis. PMID:22662039

  13. Current efficacy of antibiotics against Klebsiella isolates from urine samples - a multi-centric experience in Karachi.

    PubMed

    Abdullah, Farhan Essa; Mushtaq, Ammara; Irshad, Mubashira; Rauf, Hiba; Afzal, Noureen; Rasheed, Abdur

    2013-01-01

    Due to emergence of bacterial resistant strains, the effectiveness of current antibiotic treatment without culture/sensitivity testing is questionable. Our study aims to assess the present sensitivity profiles of Klebsiella isolates from urine samples and provide options for empiric prescription in critically ill patients. Klebsiella pneumoniae isolates collected over a period of 28 months till January 2011 from 1,617 urine samples of subjects presenting with Urinary Tract Infections were identified at a local diagnostic lab using standard protocol and subjected to Kirby-Bauer disk diffusion sensitivity testing. MICs were also estimated by E-nephelometry. Among 20 drugs used, low sensitivity was found to amoxicillin (0.1%), doxycycline (11.5%), nitrofurantoin (15.5%), amoxiclav (18.2%), gentamicin (35.4%), pipemidic acid, cephradine (40.3%) and cotrimoxazole (43.1%). The isolates were more sensitive to cefuroxime (55.9%), cefixime (57.7%), ciprofloxacin (62.5%), ofloxacin (63%), ceftriaxone (66.2%), ceftazidime (66.4%), cefotaxime (66.6%), fosfomycin (77.5%) and amikacin (89.4). Most effective were cefroperazone.sulbactam (95.8%), piperacillin.tazobactam (95.7%) and imipenem (97.7%). Self-medication, lack of awareness, and the misuse of antibiotics by doctors has exacerbated the menace of microbial resistance. The study warrants the prudent choice of drugs in adherence with prevailing sensitivity profiles. PMID:23261722

  14. Two-phase and three-phase liquid-phase microextraction of hydrochlorothiazide and triamterene in urine samples.

    PubMed

    Ahmad Panahi, Homayon; Ejlali, Maryam; Chabouk, Monireh

    2016-07-01

    This paper reports the applicability of two-phase and three-phase hollow fiber based liquid-phase microextraction (HF-LPME) for the extraction of hydrochlorothiazide (HYD) and triamterene (TRM) from human urine. The HYD in two-phase HF-LPME is extracted from 24 mL of the aqueous sample into an organic phase with microliter volume located inside the pores and lumen of a polypropylene hollow fiber as acceptor phase, but the TRM in three-phase HF-LPME is extracted from aqueous donor phase to organic phase and then back-extracted to the aqueous acceptor phase, which can be directly injected into HPLC for analysis. Under optimized conditions preconcentration factors of HYD and TRM were obtained as 128 and 239, respectively. The calibration curves were linear (R(2)  ≥ 0.995) in the concentration range of 1.0-100 µg/L for HYD and 2.0-100 µg/L for TRM. The limits of detection for HYD and TRM were 0.5 µg/L. The intra-day and inter-day RSD based on four replicates were obtained as ≤5.8 and ≤9.3%, respectively. The methods were successfully applied for determining the concentration of the drugs in urine samples. Copyright © 2015 John Wiley & Sons, Ltd. PMID:26542449

  15. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    PubMed

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. PMID:27232053

  16. Simultaneous Separation of Eight Benzodiazepines in Human Urine Using Field-Amplified Sample Stacking Micellar Electrokinetic Chromatography.

    PubMed

    Oledzka, Ilona; Kulińska, Zofia; Prahl, Adam; Baczek, Tomasz

    2015-01-01

    A novel approach for the simultaneous quantification of eight benzodiazepines (BZDs) using dispersive liquid-liquid microextraction (DLLME) and field-amplified sample stacking (FASS) combined with micellar electrokinetic chromatography (MEKC) was investigated and evaluated in the context of precision, accuracy, sensitivity, linearity, detection and limits of quantification (LOQ). The absolute recovery rates of BZDs were above 90.65%. The limits of detection (LOD) were 20 ng/mL for chlordiazepoxide, estazolam, temazepam and midazolam, and 30 ng/mL for clonazepam, lorazepam, lormetazepam and medazepam, while the LOQ was set at 50 ng/mL for chlordiazepoxide, estazolam, temazepam and midazolam, and 100 ng/mL for clonazepam, lorazepam, lormetazepam and medazepam. Linearity was confirmed in the range of 50-2,000 ng/mL for chlordiazepoxide, estazolam, temazepam and midazolam, and 100-2,000 ng/mL for clonazepam, lorazepam, lormetazepam and medazepam, with a correlation coefficient greater than 0.9987 for all analytes. The elaborated procedure meets all the requirements of analytical methods. During the extraction procedure, a mixture of 1 mL of ethanol and 500 µL of dichloromethane, used as the disperser and extraction solvent, respectively, was rapidly injected into 3 mL of a urine sample. A significant improvement in sensitivity was achieved when DLLME was used to extract BZDs from the urine sample and FASS as an on-line preconcentration technique was developed. For the best separation of analytes, the running buffer was composed of 30 mM SDS, 10 mM sodium tetraborate and 15% methanol (pH 8.8), whereas a sample buffer was composed of 10 mM SDS and 2 mM sodium tetraborate. Moreover, a fused-silica capillary [inner diameter (i.d.) of 75 µm and length of 50 cm], photodiode array detection, pneumatic injection for 15 s and a voltage of 23 kV were applied. The applicability of the method has been confirmed for the analysis of BZD in urine samples collected from patients who

  17. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  18. Antibiotic resistance pattern of Pseudomonas aeruginosa isolated from urine samples of Urinary Tract Infections patients in Karachi, Pakistan

    PubMed Central

    Shah, Dania Aijaz; Wasim, Shehnaz; Essa Abdullah, Farhan

    2015-01-01

    Objective: The aim of this study was to evaluate the antibiotic resistance pattern of Psedomonas aeruginosa and its prevalence in patients with urinary tract infections (UTI) for effective treatment in a developing country like Pakistan. Methods: This is an observational study conducted for a period of ten months which ended on December 2013 at the Dr. Essa Laboratory and Diagnostic Centre in Karachi. A total of 4668 urine samples of UTI patients were collected and standard microbiological techniques were performed to identify the organisms in urine cultures. Antibiotic susceptibility testing was performed by Kirby-Bauer technique for twenty five commonly used antimicrobials and then analyzed on SPSS version 17. Results: P. aeruginosa was isolated in 254 cultures (5.4%). The most resistant drugs included Ceclor(100%) and Cefizox (100%) followed by Amoxil/Ampicillin (99.6%), Ceflixime (99.6%), Doxycycline (99.6%), Cefuroxime (99.2%), Cephradine (99.2%), Cotrimoxazole (99.2%), Nalidixic acid (98.8%), Pipemidic acid (98.6%) and Augmentin (97.6%). Conclusion: Emerging resistant strains of Pseudomonas aeruginosa are potentially linked to injudicious use of drugs leading to ineffective empirical therapy and in turn, appearance of even more resistant strains of the bacterium. Therefore, we recommend culture and sensitivity testing to determine the presence of P.aeruginosa prior to specific antimicrobial therapy. PMID:26101487

  19. Urine odor

    MedlinePlus

    Urine odor refers to the smell from your urine. Urine odor varies. Most of the time, urine does not ... Most changes in urine odor are not a sign of disease and go away in time. Some foods and medicines, including vitamins, may affect your ...

  20. An analysis of the impact of pre‐analytical factors on the urine proteome: Sample processing time, temperature, and proteolysis

    PubMed Central

    Hepburn, Sophie; Cairns, David A.; Jackson, David; Craven, Rachel A.; Riley, Beverley; Hutchinson, Michelle; Wood, Steven; Smith, Matthew Welberry; Thompson, Douglas

    2015-01-01

    Purpose We have examined the impact of sample processing time delay, temperature, and the addition of protease inhibitors (PIs) on the urinary proteome and peptidome, an important aspect of biomarker studies. Experimental design Ten urine samples from patients with varying pathologies were each divided and PIs added to one‐half, with aliquots of each then processed and frozen immediately, or after a delay of 6 h at 4°C or room temperature (20–22°C), effectively yielding 60 samples in total. Samples were then analyzed by 2D‐PAGE, SELDI‐TOF‐MS, and immunoassay. Results Interindividual variability in profiles was the dominant feature in all analyses. Minimal changes were observed by 2D‐PAGE as a result of delay in processing, temperature, or PIs and no changes were seen in IgG, albumin, β2‐microglobulin, or α1‐microglobulin measured by immunoassay. Analysis of peptides showed clustering of some samples by presence/absence of PIs but the extent was very patient‐dependent with most samples showing minimal effects. Conclusions and clinical relevance The extent of processing‐induced changes and the benefit of PI addition are patient‐ and sample‐dependent. A consistent processing methodology is essential within a study to avoid any confounding of the results. PMID:25400092

  1. (1)H NMR-based metabolite profiling workflow to reduce inter-sample chemical shift variations in urine samples for improved biomarker discovery.

    PubMed

    Gil, Ryan B; Lehmann, Rainer; Schmitt-Kopplin, Philippe; Heinzmann, Silke S

    2016-07-01

    Metabolite profiling of urine has seen much advancement in recent years, and its analysis by nuclear magnetic resonance (NMR) spectroscopy has become well established. However, the highly variable nature of human urine still requires improved protocols despite some standardization. In particular, diseases such as kidney disease can have a profound effect on the composition of urine and generate a highly diverse sample set for clinical studies. Large variations in pH and the cationic concentration of urine play an important role in creating positional noise within datasets generated from NMR. We demonstrate positional noise to be a confounding variable for multivariate statistical tools such as statistical total correlation spectroscopy (STOCSY), thereby hindering the process of biomarker discovery. We present a two-dimensional buffering system using potassium fluoride (KF) and phosphate buffer to reduce positional noise in metabolomic data generated from urine samples with various levels of proteinuria. KF reduces positional noise in citrate peaks, by decreasing the mean relative standard deviation (RSD) from 0.17 to 0.09. By reducing positional noise with KF, STOCSY analysis of citrate peaks saw significant improvement. We further aligned spectral data using a recursive segment-wise peak alignment (RSPA) method, which leads to further improvement of the positional noise (RSD = 0.06). These results were validated using diverse selection of metabolites which lead to an overall improvement in positional noise using the suggested protocol. In summary, we provide an improved workflow for urine metabolite biomarker discovery to achieve higher data quality for better pathophysiological understanding of human diseases. Graphical abstract Citrate peaks in the range 2.75-2.5 ppm from datasets with different sample preparation protocols and with/without in silico alignment. A Citrate peaks with standard phosphate buffering and without in silico alignment. B citrate

  2. Urine-sample-derived human induced pluripotent stem cells as a model to study PCSK9-mediated autosomal dominant hypercholesterolemia

    PubMed Central

    Si-Tayeb, Karim; Idriss, Salam; Champon, Benoite; Caillaud, Amandine; Pichelin, Matthieu; Arnaud, Lucie; Lemarchand, Patricia; Le May, Cédric; Zibara, Kazem; Cariou, Bertrand

    2016-01-01

    ABSTRACT Proprotein convertase subtilisin kexin type 9 (PCSK9) is a critical modulator of cholesterol homeostasis. Whereas PCSK9 gain-of-function (GOF) mutations are associated with autosomal dominant hypercholesterolemia (ADH) and premature atherosclerosis, PCSK9 loss-of-function (LOF) mutations have a cardio-protective effect and in some cases can lead to familial hypobetalipoproteinemia (FHBL). However, limitations of the currently available cellular models preclude deciphering the consequences of PCSK9 mutation further. We aimed to validate urine-sample-derived human induced pluripotent stem cells (UhiPSCs) as an appropriate tool to model PCSK9-mediated ADH and FHBL. To achieve our goal, urine-sample-derived somatic cells were reprogrammed into hiPSCs by using episomal vectors. UhiPSC were efficiently differentiated into hepatocyte-like cells (HLCs). Compared to control cells, cells originally derived from an individual with ADH (HLC-S127R) secreted less PCSK9 in the media (−38.5%; P=0.038) and had a 71% decrease (P<0.001) of low-density lipoprotein (LDL) uptake, whereas cells originally derived from an individual with FHBL (HLC-R104C/V114A) displayed a strong decrease in PCSK9 secretion (−89.7%; P<0.001) and had a 106% increase (P=0.0104) of LDL uptake. Pravastatin treatment significantly enhanced LDL receptor (LDLR) and PCSK9 mRNA gene expression, as well as PCSK9 secretion and LDL uptake in both control and S127R HLCs. Pravastatin treatment of multiple clones led to an average increase of LDL uptake of 2.19±0.77-fold in HLC-S127R compared to 1.38±0.49 fold in control HLCs (P<0.01), in line with the good response to statin treatment of individuals carrying the S127R mutation (mean LDL cholesterol reduction=60.4%, n=5). In conclusion, urine samples provide an attractive and convenient source of somatic cells for reprogramming and hepatocyte differentiation, but also a powerful tool to further decipher PCSK9 mutations and function. PMID:26586530

  3. A dried urine spot test to simultaneously monitor Mo and Ti levels using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Rello, L.; Lapeña, A. C.; Aramendía, M.; Belarra, M. A.; Resano, M.

    2013-03-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients that require frequent controls, such as patients with metallic prosthesis, for whom monitoring the evolution of Mo and Ti in biological fluids may play a decisive role to detect prosthesis mal-functioning. The collection of biological fluids on clinical filter papers provides a simple way to implement these protocols. This work explores the potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous and direct determination of Mo and Ti in urine, after its deposition onto clinical filter paper, giving rise to a dried urine spot. The approach used for depositing the sample was found crucial to develop a quantitative method, since the filter paper acts as a chromatographic support and produces a differential distribution of the target analytes. Furthermore, the high spreading of urine onto a filter paper results in a small amount of urine per surface unit, and thus, ultimately, in lack of sensitivity. In order to circumvent these problems, the use of an alternative approach based on the use of pre-cut 17 × 19 mm filter paper pieces onto which larger amounts of sample (500 μL) can be retained by single deposition was proposed and evaluated. In this way, an approximately 12-fold increase in sensitivity and a more homogeneous distribution of the target analytes were obtained, permitting the development of a quantification strategy based on the use of matrix-matched urine samples of known analyte concentrations, which were subjected to the same procedure as the samples. Accuracy of this method, which provides LODs of 1.5 μg L- 1 for Mo and 6.5 μg L- 1 for Ti, was demonstrated after analysis of urine reference materials. Overall, the performance of the method developed is promising, being likely suitable for determination of other analytes in dried urine spots.

  4. Determination of cocaine and methadone in urine samples by thin-film solid-phase microextraction and direct analysis in real time (DART) coupled with tandem mass spectrometry.

    PubMed

    Rodriguez-Lafuente, Angel; Mirnaghi, Fatemeh S; Pawliszyn, Janusz

    2013-12-01

    The use of thin-film solid-phase microextraction (SPME) as the sampling preparation step before direct analysis in real time (DART) was evaluated for the determination of two prohibited doping substances, cocaine and methadone, in urine samples. Results showed that thin-film SPME improves the detectability of these compounds: signal-to-blank ratios of 5 (cocaine) and 13 (methadone) were obtained in the analysis of 0.5 ng/ml in human urine. Thin-film SPME also provides efficient sample cleanup, avoiding contamination of the ion source by salt residues from the urine samples. Extraction time was established in 10 min, thus providing relatively short analysis time and high throughput when combined with a 96-well shaker and coupled with DART technique. PMID:23685960

  5. Urine culture

    MedlinePlus

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  6. Microarray-based identification of lectins for the purification of human urinary extracellular vesicles directly from urine samples.

    PubMed

    Echevarria, Juan; Royo, Felix; Pazos, Raquel; Salazar, Lorena; Falcon-Perez, Juan Manuel; Reichardt, Niels-Christian

    2014-07-21

    As cellular-derived vesicles largely maintain the biomolecule composition of their original tissue, exosomes, which are found in nearly all body fluids, have enormous potential as clinical disease markers. A major bottleneck in the development of exosome-based diagnostic assays is the challenging purification of these vesicles; this requires time-consuming and instrument-based procedures. We employed lectin arrays to identify potential lectins as probes for affinity-based isolation of exosomes from the urinary matrix. We found three lectins that showed specific interactions to vesicles and no (or only residual) interaction with matrix proteins. Based on these findings a bead-based method for lectin-based isolation of exosomes from urine was developed as a sample preparation step for exosome-based biomarker research. PMID:25044519

  7. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING URINE SAMPLES FOR ANALYSIS OF HYDROXY POLYCYCLIC AROMATIC HYDROCARBONS, PENTACHLOROPHENOL AND 2,4-D (SOP-5.21)

    EPA Science Inventory

    The method for extracting and preparing urine samples for analysis of hydroxy-polycyclic aromatic hydrocarbons, pentachlorophenol and 2,4-D is summarized in this SOP. It covers the extraction, concentration and methylation of samples that are to be analyzed by gas chromatography/...

  8. A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid-liquid microextraction.

    PubMed

    Vela-Soria, F; Ballesteros, O; Zafra-Gómez, A; Ballesteros, L; Navalón, A

    2014-11-01

    The population is continuously exposed to endocrine disrupting chemicals (EDCs). This has influenced an increase in diseases and syndromes that are more frequent nowadays. Therefore, it is necessary to develop new analytical procedures to evaluate the exposure with the ultimate objective of establishing, in an accurate way, relationships between EDCs and harmful health effects. In the present work, a new method based on a sample treatment by dispersive liquid-liquid microextraction (DLLME) for the extraction of six parabens (methyl-, ethyl-, isopropyl-, propyl-, isobutyl and butylparaben), six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) and two bisphenols (bisphenol A and bisphenol S) in human urine samples, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis is proposed. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-(13)C6 and bisphenol A-d16 were used as surrogates. Found limits of quantification ranging from 0.2 to 0.5 ng mL(-1) and inter-day variability (evaluated as relative standard deviation) ranging from 2.0% to 14.9%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94% to 105%. A good linearity, for concentrations up to 300 ng mL(-1) for parabens and 40 ng mL(-1) for benzophenones and bisphenols, respectively, was obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals. PMID:25127586

  9. Preparation of magnetic ODS-PAN thin-films for microextraction of quetiapine and clozapine in plasma and urine samples followed by HPLC-UV detection.

    PubMed

    Li, Dan; Zou, Juan; Cai, Pei-Shan; Xiong, Chao-Mei; Ruan, Jin-Lan

    2016-06-01

    In this study, conventional thin-film microextraction (TFME) was endowed with magnetic by introducing superparamagnetic SiO2@Fe3O4 nanoparticles in thin-films. Novel magnetic octadecylsilane (ODS)-polyacrylonitrile (PAN) thin-films were prepared by spraying, and used for the microextraction of quetiapine and clozapine in plasma and urine samples, followed by the detection of HPLC-UV. The influencing factors on the extraction efficiency of magnetic ODS-PAN TFME, including pH, extraction time, desorption solvent, desorption time, and ion strength were investigated systematically. Under the optimal conditions, both analytes showed good linearity over ranges of 0.070-9.000μgmL(-1) and 0.012-9.000μgmL(-1) in plasma and urine samples, respectively, with correlation coefficients (R(2)) above 0.9990. Limits of detection (LODs) for quetiapine in plasma and urine samples were 0.013 and 0.003μgmL(-1), respectively. LODs for clozapine in plasma and urine samples were 0.015 and 0.003μgmL(-1), respectively. The relative standard deviations (RSDs) for quetiapine and clozapine were less than 9.23%. After the validation, the protocol was successfully applied for the determination of quetiapine and clozapine in patients' plasma and urine samples with satisfactory recoveries between 99-110%. The proposed magnetic ODS-PAN TFME was very simple, fast and easy to handle. It showed high potential as a powerful pretreatment technology for routine therapeutic drug monitoring (TDM) in plasma and urine samples. PMID:27085135

  10. Diagnostic Value of PCR for Detection of Borrelia burgdorferi in Skin Biopsy and Urine Samples from Patients with Skin Borreliosis

    PubMed Central

    Brettschneider, S.; Bruckbauer, H.; Klugbauer, N.; Hofmann, H.

    1998-01-01

    Skin biopsies of 36 patients with erythema migrans and acrodermatitis chronica atrophicans (ACA) before therapy and those of 8 patients after therapy were examined for Borrelia burgdorferi DNA by PCR. Skin biopsies of 27 patients with dermatological diseases other than Lyme borreliosis and those of 10 healthy persons were examined as controls. Two different primer sets targeting 23S rRNA (PCR I) and 66-kDa protein (PCR II) genes were used. PCR was performed with freshly frozen tissue (FFT) and paraffin-embedded tissue (PET). For FFT specimens of erythema migrans, 73% were positive by PCR I, 79% were positive by PCR II, and 88% were positive by combining PCR I and II. For PET specimens, PCR was less sensitive (PCR I, 44%; PCR II, 52%). For FFT specimens of ACA, PCR I was positive for two of five patients and PCR II was positive for four of five patients. B. burgdorferi was cultured from 79% of the erythema migrans specimens but not from any of the ACA lesions. Elevated B. burgdorferi antibodies were detected in sera of 74% of erythema migrans patients and 100% of ACA patients. All urine samples were negative by PCR II, whereas PCR I was positive for 27%. However, hybridization of these amplicons was negative. Sequencing of three amplicons identified nonborrelial DNA. In conclusion, urine PCR is not suitable for the diagnosis of skin borreliosis. A combination of two different primer sets achieves high sensitivity with skin biopsies. In early erythema migrans infection, culture and PCR are more sensitive than serology. PMID:9705410

  11. Rapid determination of nine parabens and seven other environmental phenols in urine samples of German children and adults.

    PubMed

    Moos, Rebecca K; Angerer, Jürgen; Wittsiepe, Jürgen; Wilhelm, Michael; Brüning, Thomas; Koch, Holger M

    2014-11-01

    We developed a fast, selective and sensitive on-line LC/LC-MS/MS method for the simultaneous determination of nine parabens and seven environmental phenols in urine. Parabens are widely used as antimicrobial preservatives. Bisphenol A, triclosan, triclocarban, 2-phenylphenol, and benzophenones are used inter alia in disinfectants, sunscreens and in polymers. Some of these substances are suspected endocrine disruptors. Limits of quantification and analytical quality criteria fully met the needs for determining exposure levels occurring in the general population. We analyzed 157 spot urine samples from the general German population (59 females, 39 males and 59 children). For the parabens, we found methyl, ethyl and n-propyl paraben with high detection rates (77-98%), followed by n-butyl (36%), iso-butyl (17%), iso-propyl (3%) and benzyl paraben (3%). We detected no pentyl and heptyl paraben. Urinary concentrations were highest for methyl paraben (median 24.5 μg/L; 95th percentile 379 μg/L) followed by ethyl (1.4 μg/L; 35.2 μg/L) and n-propyl paraben (1.2 μg/L; 68.1 μg/L). Other environmental phenols with high detection rates were BPA (95%), triclosan (45%) and benzophenone 1 and 3 (26%). For most of the parabens/environmental phenols we found higher urinary levels in females than in males or children, probably due to differences in (personal care) product use. However, high levels (in the mg/L range) were also observed in children. Exposure to the above substances is occurring worldwide. Differences between countries do seem to exist and might be caused by different product compositions or different use habits. Human metabolism data is urgently needed to extrapolate from urinary biomarker levels to doses actually taken up. PMID:25008406

  12. Mercapturic acids derived from toluene in rat urine samples: identification and measurement by gas chromatography-tandem mass spectrometry.

    PubMed

    Cosnier, Frédéric; Brochard, Céline; Burgart, Manuella; Cossec, Benoît

    2012-10-01

    Toluene is one of the most widely used CMR chemicals in industry. Worker exposure to this compound is regulated in France, but new, more sensitive methods are required to effectively monitor this exposure. A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed and fully validated for the simultaneous determination of urinary toluene mercapturic acids derived from side chain and ring oxidation, i.e., benzylmercapturic acid and the three isomers o-, m- and p-toluylmercapturic acids, respectively. The method involves a simple and efficient two-step preparation procedure consisting of liquid-liquid extraction of the urinary acids followed by a microwave-assisted esterification of the isolated compounds using 2-propanol. The method meets all the required validation criteria: high selectivity, intra-day and inter-day precision ranges between 1.0 % and 12.4 %, with close to 100 % recovery. Linearity has been shown over the reduced concentration range 0.03-0.5 mg/L whereas a multiplicative model (ln-ln transformation) had to be used to describe the full range of concentrations 0.03-20 mg/L. The limits of detection for the four analytes, ranging from 2.8 to 5.5 μg/L, made the method suitable for their identification and quantification in urine from rats inhaling toluene in the 2 to 200 ppm concentration range. All urine samples from exposed rats contained measurable amounts of all metabolites. This is the first time that o- and m-toluylmercapturic acids have been shown to occur. Our results confirm the hypothesis that toluene mercapturic acids derived from ring oxidation exist in three forms. PMID:22829455

  13. Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

    PubMed

    Chen, Hsin-Chang; Wu, Charlene; Wu, Kuen-Yuh

    2015-05-01

    A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of SpragueDawley (SD) rats. The aforementioned biological samples were spiked with (13)C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE-LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R(2)) greater than 0.999; the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5μg L(-1), respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0% to 100.2% and 101.3% to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6% to 101.0% and from 102.3% to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p=0.9145 and p=0.5378, correspondingly) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats, demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at part-per-billion levels concentrations in complex matrices. PMID:25702978

  14. Strong-LAMP: A LAMP Assay for Strongyloides spp. Detection in Stool and Urine Samples. Towards the Diagnosis of Human Strongyloidiasis Starting from a Rodent Model

    PubMed Central

    Gandasegui, Javier; Bajo Santos, Cristina; López-Abán, Julio; Saugar, José María; Rodríguez, Esperanza; Vicente, Belén; Muro, Antonio

    2016-01-01

    Background Strongyloides stercoralis, the chief causative agent of human strongyloidiasis, is a nematode globally distributed but mainly endemic in tropical and subtropical regions. Chronic infection is often clinically asymptomatic but it can result in severe hyperinfection syndrome or disseminated strongyloidiasis in immunocompromised patients. There is a great diversity of techniques used in diagnosing the disease, but definitive diagnosis is accomplished by parasitological examination of stool samples for morphological identification of parasite. Until now, no molecular method has been tested in urine samples as an alternative to stool samples for diagnosing strongyloidiasis. This study aimed to evaluate the use of a new molecular LAMP assay in a well-established Wistar rat experimental infection model using both stool and, for the first time, urine samples. The LAMP assay was also clinically evaluated in patients´ stool samples. Methodology/Principal Findings Stool and urine samples were obtained daily during a 28-day period from rats infected subcutaneously with different infective third-stage larvae doses of S. venezuelensis. The dynamics of parasite infection was determined by daily counting the number of eggs per gram of feces from day 1 to 28 post-infection. A set of primers for LAMP assay based on a DNA partial sequence in the 18S rRNA gene from S. venezuelensis was designed. The set up LAMP assay (namely, Strong-LAMP) allowed the sensitive detection of S. venezuelensis DNA in both stool and urine samples obtained from each infection group of rats and was also effective in S. stercoralis DNA amplification in patients´ stool samples with previously confirmed strongyloidiasis by parasitological and real-time PCR tests. Conclusions/Significance Our Strong-LAMP assay is an useful molecular tool in research of a strongyloidiasis experimental infection model in both stool and urine samples. After further validation, the Strong-LAMP could also be potentially

  15. Osmolality urine - series (image)

    MedlinePlus

    ... midstream) urine sample. To obtain a clean-catch sample, men or boys should wipe clean the head of the penis. Women or girls need to wash the area between the lips of the vagina with soapy water and rinse well. As you start to urinate, ...

  16. Metabolite profiles of repeatedly sampled urine from male fathead minnows (Pimephales promelas) contain unique lipid signatures following exposure to anti-androgens.

    PubMed

    Collette, Timothy W; Skelton, David M; Davis, John M; Cavallin, Jenna E; Jensen, Kathleen M; Kahl, Michael D; Villeneuve, Daniel L; Ankley, Gerald T; Martinović-Weigelt, Dalma; Ekman, Drew R

    2016-09-01

    The purpose of this study was twofold. First, we sought to identify candidate markers of exposure to anti-androgens by analyzing endogenous metabolite profiles in the urine of male fathead minnows (mFHM, Pimephales promelas). Based on earlier work, we hypothesized that unidentified lipids in the urine of mFHM were selectively responsive to exposure to androgen receptor antagonists, which is otherwise difficult to confirm using established fish toxicity assays. A second goal was to evaluate the feasibility of non-lethally and repeatedly sampling urine from individual mFHMs over the time course of response to a chemical exposure. Accordingly, we exposed mFHM to the model anti-androgens vinclozolin or flutamide. Urine was collected from each fish at 48hour intervals over the course of a 14day exposure. Parallel experiments were conducted with mFHM exposed to bisphenol A or control water. The frequent handling/sampling regime did not cause apparent adverse effects on the fish. Endogenous metabolite profiling was conducted with gas chromatography-mass spectrometry (GC-MS), which exhibited lower variation for the urinary metabolome than was found in earlier work with nuclear magnetic resonance (NMR) spectroscopy. Specifically, for inter- and intra-individual variations, the median spectrum-wide relative standard deviation (RSD) was 32.6% and 33.3%, respectively, for GC-MS analysis of urine from unexposed mFHM. These results compared favorably with similar measurements of urine from other model species, including the Sprague Dawley rat. In addition, GC-MS allowed us to identify several lipids (e.g., certain saturated fatty acids) in mFHM urine as candidate markers of exposure to androgen receptor antagonists. PMID:26810197

  17. Screening of citalopram, fluoxetine and their metabolites in human urine samples by gas chromatography-mass spectrometry. A global robustness/ruggedness study.

    PubMed

    Berzas Nevado, J J; Villaseñor Llerena, M J; Guiberteau Cabanillas, C; Rodríguez Robledo, V

    2006-08-01

    Capillary gas chromatography with mass spectrometry detection in SIM mode (GC-MS-SIM) has been used for the analysis of citalopram (CIT), fluoxetine (FLX), and all of their metabolites in urine samples. The instrumental parameters affecting GC separation and MS-SIM detection were investigated. A validation procedure was performed on urine matrix and a simultaneous robustness/ruggedness evaluation is also presented in this paper. An optimized solid-phase extraction (SPE) has been applied, reaching in this way to limits of detection (LODs) between 0.7 ng L(-1) (CIT) and 33.6 microg L(-1) (CIT-PA). A pharmacokinetic screening in clinical urine samples has been also carried out. PMID:16814307

  18. SIMPLE SAMPLE CLEAN UP PROCEDURE AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF CYANURIC ACID IN HUMAN URINE

    EPA Science Inventory

    Cyanuric acide (CA) is widely used as a chlorine stabilizer in outdoor pools. No simple method exists for CA measurement in the urine of exposed swimmers. The high hydrophilicity of CA makes usage of solid phase sorbents to extract it from urine nearly impossible because of samp...

  19. Quantitation of sunitinib, an oral multitarget tyrosine kinase inhibitor, and its metabolite in urine samples by nonaqueous capillary electrophoresis time of flight mass spectrometry.

    PubMed

    Rodríguez, Juana; Castañeda, Gregorio; Muñoz, Lorena; Villa, Jose C

    2015-07-01

    A rapid, sensitive, and specific method was developed and validated using a nonaqueous-capillary electrophoresis method with TOF-MS for determination of sunitinib and N-desethyl sunitinib in human urine. In order to avoid ionic suppression a urine samples dilution with methanol 1:10 previous step was used. This was the only treatment step to urine samples before the injection. Despite this dilution of the urine, the detection limit was as low as 0.07 mg/L for sunitinib and 0.15 mg/L for N-desethyl sunitinib. Separation of compounds was achieved with a mixture of 5 mM ammonium formate in methanol. The calibration curves were linear over the range of 0.5-50.0 mg/L for the two analyzed compounds. The within-run and between-run precisions were within 5%, while the accuracy ranged from 96.0 to 100.4%. This method can be used in routine clinical practice to monitor sunitinib and N-desethyl sunitinib drugs in the urine of cancer patients treated with once daily administration. PMID:25873554

  20. Monitoring of biogenic amines and drugs of various therapeutic groups in urine samples with use of HPLC.

    PubMed

    Baranowska, Irena; Płonka, Joanna

    2016-04-01

    A high-performance liquid chromatography method for simultaneous separation and determination of biogenic amines [dopamine, epinephrine, serotonin and its six metabolites (normetanephrine, metanephrine, 3,4-dihydroxyphenylacetic acid, 4-hydroxy-3-methoxyphenylglycol, homovanilic acid and 5-hydroxyindoloacetic acid)] with drugs from different therapeutically groups [analgesics (paracetamol, metamizol), diuretics (furosemide) and antibiotics (cefazolin, fluconazole)] was developed. A chromatographic column with pre-column with octadecylsilane phase (C18e ) and two detectors - diode array serial connected and fluorescence - was used. Gradient elution of mixture of acetate buffer (pH 4.66) and methanol as a mobile phase was applied. The limit of detection (LOD) of 8-10 ng/mL and limit of quantitation (LOQ) of 24-30 ng/mL for biogenic amines, as well as the LOD of 50-100 ng/mL and the LOQ of 150-300 ng/mL for drugs, were determined. The applied sample preparation method allowed recoveries of 93% for the biogenic amines and 92% for the drugs to be achieved. The developed procedure has been applied to simultaneous determination of the examined compounds in urine samples and could be used in clinical analysis. PMID:26362402

  1. Development of ultrasound-assisted emulsification microextraction for determination of thiocynate ion in human urine and saliva samples.

    PubMed

    Hashemi, Mahdi; Daryanavard, Seyed Mosayeb; Abdolhosseini, Sana

    2013-02-15

    Ultrasound-assisted emulsification microextraction (USAE-ME) procedure coupled with UV-vis spectrophotometric measurement has been developed for determination of thiocyanate ion (SCN(-)) in water and biological fluids samples. The method is based on protonation of SCN(-) ions in acidic medium and extraction of thiocyanic acid into fine droplets of chloroform as an extraction solvent contains rhodamine B (RhB). The RhB was protonated in presence of thiocynanic acid to form highly colored ion-pair complex of [thiocynate][RhBH(+)] in chloroform, which used for subsequent spectrophotometric determination of SCN(-) ions. Experimental parameters for both spectrophotometric reaction and USAE-ME procedure have been optimized. Under optimized conditions the calibration curve for SCN(-) showed good linearity in the range of 38.0-870.0ngmL(-1) (R(2)=0.9967). The limit of detection (S/N=3) and preconcentration factor were 5.0ngmL(-1) and 40, respectively. Relative standard deviation for determination of 200ngmL(-1) of SCN(-) was 2.8% (n=5). The proposed method has been successfully applied for determination of SCN(-) ion in tap water, mineral bottled water and human saliva and urine samples with an average recovery of 99.2%. PMID:23353810

  2. Surface molecularly imprinted silica for selective solid-phase extraction of biochanin A, daidzein and genistein from urine samples.

    PubMed

    Chrzanowska, Anna M; Poliwoda, Anna; Wieczorek, Piotr P

    2015-05-01

    Selective molecularly imprinted silica polymer (SiO2MIP) for extraction of biochanin A, daidzein and genistein was synthesized using the surface molecular imprinting technique with the silica gel as a support. Biochanin A (BCA) was used as a template, 3-aminopropyltriethoxysilane (APTES) as a functional monomer, and tetraethoxysilicane (TEOS) as a cross-linker. Non-imprinted polymer with the sol-gel process (SiO2NIP) was also prepared for comparison. The synthesized polymers were characterized by Fourier transform infrared spectrometry (FTIR), scanning electron microscopy (SEM) and a standard Brunauer-Emett-Teller (BET) and Barret-Joyner-Halenda (BJH) analysis. The obtained results indicated the structural differences between imprinted and non-imprinted polymers. Finally, the SiO2MIP and SiO2NIP were adopted as the adsorbents of solid phase extraction for isolation and preconcentration of biochanin A and its structural analogues-daidzein and genistein from aqueous and urine samples. The performance analysis revealed that SiO2MIP displayed better affinity to the three investigated isoflavones compared with SiO2NIP. The recoveries of spiked samples for studied analytes ranged from 65.7% to 102.6% for molecularly imprinted silica polymer and 8.9-16.0% for non-imprinted sorbents. PMID:25817705

  3. Molecularly imprinted polymeric stir bar: Preparation and application for the determination of naftopidil in plasma and urine samples.

    PubMed

    Peng, Jun; Xiao, Deli; He, Hua; Zhao, Hongyan; Wang, Cuixia; Shi, Tian; Shi, Kexin

    2016-01-01

    In this study, molecularly imprinting technology and stir bar absorption technology were combined to develop a microextraction approach based on a molecularly imprinted polymeric stir bar. The molecularly imprinted polymer stir bar has a high performance, is specific, economical, and simple to prepare. The obtained naftopidil-imprinted polymer-coated bars could simultaneously agitate and adsorb naftopidil in the sample solution. The ratio of template/monomer/cross-linker and conditions of template removal were optimized to prepare a stir bar with highly efficient adsorption. Fourier transform infrared spectroscopy, scanning electron microscopy, selectivity, and extraction capacity experiments showed that the molecularly imprinted polymer stir bar was prepared successfully. To utilize the molecularly imprinted polymer stir bar for the determination of naftopidil in complex body fluid matrices, the extraction time, stirring speed, eluent, and elution time were optimized. The limits of detection of naftopidil in plasma and urine sample were 7.5 and 4.0 ng/mL, respectively, and the recoveries were in the range of 90-112%. The within-run precision and between-run precision were acceptable (relative standard deviation <7%). These data demonstrated that the molecularly imprinted polymeric stir bar based microextraction with high-performance liquid chromatography was a convenient, rapid, efficient, and specific method for the precise determination of trace naftopidil in clinical analysis. PMID:26541792

  4. No Effect of Route of Exposure (Oral; Subcutaneous Injection) on Plasma Bisphenol A throughout 24 hr after Administration in Neonatal Female Mice

    PubMed Central

    Taylor, Julia A.; Welshons, Wade V.; vom Saal, Frederick S.

    2008-01-01

    Route of administration of chemicals in adults is an important factor in pharmacokinetics of chemicals such as bisphenol A (BPA), the monomer with estrogenic activity used to make polycarbonate plastic products and to line food and beverage cans. Based on findings in adults it has been proposed (CERHR, 2007) that non-oral routes of administration in newborn rodents would also lead to high exposure relative to oral administration. However, in fetuses and neonates, the enzyme that conjugates BPA (UDP-glucuronosyltransferase) is expressed at low levels, suggesting that there may be no differences in pharmacokinetics between oral and non-oral dosing. We thus conducted an analysis of plasma concentrations of unconjugated 3H-BPA after HPLC separation in postnatal day 3 female mice throughout the 24 hr after administering 3H-BPA orally or via subcutaneous injection at doses above and below the current EPA reference dose. We found no significant difference in plasma BPA based on route of administration in neonatal mice at either dose. However, compared to data from other studies conducted with adults, there was a markedly higher plasma BPA level after oral administration of BPA in newborn mice. This finding sets aside the belief that non-oral administration of BPA renders data as not suitable for consideration of the hazard posed by low-dose exposure to BPA during neonatal life. Therefore the large numbers of BPA studies that used non-oral administration at very low doses during the neonatal period should not be dismissed by scientists or the regulatory community based on route of administration. PMID:18295446

  5. Determination of Parent and Hydroxy PAHs in Personal PM2.5 and Urine Samples Collected During Native American Fish Smoking Activities

    PubMed Central

    Motorykin, Oleksii; Schrlau, Jill; Jia, Yuling; Harper, Barbara; Harris, Stuart; Harding, Anna; Stone, David; Kile, Molly; Sudakin, Daniel; Massey Simonich, Staci L.

    2014-01-01

    A method was developed for the measurement of 19 parent PAHs (PAHs) and 34 hydroxylated PAHs (OH-PAHs) in urine and personal air samples of particulate matter less than 2.5 um in diameter (PM2.5) using GC-MS and validated using NIST SRM 3672 (Organic Contaminants in Smoker’s Urine) and SRM 3673 (Organic Contaminants in Nonsmoker’s Urine). The method was used to measure PAHs and OH-PAHs in urine and personal PM2.5 samples collected from the operators of two different fish smoking facilities (tipi and smoke shed) burning two different wood types (alder and apple) on the Confederated Tribes of Umatilla Indian Reservation (CTUIR) while they smoked salmon. Urine samples were spiked with β-glucuronidase/arylsulfatase to hydrolyze the conjugates of OH-PAHs and the PAHs and OH-PAHs were extracted using Plexa and C18 solid phases, in series. The 34OH-PAHs were derivatized using MTBSTFA, and the mixture was measured by GC-MS. The personal PM2.5samples were extracted using pressurized liquid extraction, derivatized with MTBSTFA and analyzed by GC-MS for PAHs and OH-PAHs. Fourteen isotopically labeled surrogates were added to accurately quantify PAHs and OH-PAHs in the urine and PM2.5 samples and three isotopically labeled internal standards were used to calculate the recovery of the surrogates. Estimated detection limits in urine ranged from 6.0 to 181 pg/ml for OH-PAHs and from 3.0 to 90 pg/ml for PAHs, and, in PM2.5, they ranged from 5.2 to 155 pg/m3 for OH-PAHs and from 2.5 to 77 pg/m3 for PAHs. The results showed an increase in OH-PAH concentrations in urine after 6 hours offish smoking and an increase in PAH concentrations in air within each smoking facility. In general, the PAH exposure in the smoke shed was higher than in the tipi and the PAH exposure from burning apple wood was higher than burning alder. PMID:25461072

  6. Isotope concentrations from 24-h urine and 3-h serum samples can be used to measure intestinal magnesium absorption in postmenopausal women.

    PubMed

    Hansen, Karen E; Nabak, Andrea C; Johnson, Rachael Erin; Marvdashti, Sheeva; Keuler, Nicholas S; Shafer, Martin M; Abrams, Steven A

    2014-04-01

    Studies suggest a link between magnesium status and osteoporosis. One barrier to more conclusive research on the potential relation is measuring intestinal magnesium absorption (MgA), which requires the use of stable isotopes and a ≥6-d stool or 3-d urine collection. We evaluated alternative methods of measuring MgA. We administered 2 stable magnesium isotopes to 15 postmenopausal women (cohort 1) aged 62 ± 8 y with a dietary magnesium intake of 345 ± 72 mg/d. Participants fasted from 1200 h to 0700 h and then consumed breakfast with ∼23 mg of oral ²⁶Mg and ∼11 mg of i.v. ²⁵Mg. We measured magnesium isotope concentrations in 72-h urine, spot urine (36, 48, 60, and 72 h), and spot serum (1, 3, and 5 h) samples collected after isotope dosing. We calculated MgA using the dose-corrected fraction of isotope concentrations from the 72-h urine collection. We validated new methods in 10 postmenopausal women (cohort 2) aged 59 ± 5 y with a dietary magnesium intake of 325 ± 122 mg/d. In cohort 1, MgA based on the 72-h urine collection was 0.28 ± 0.08. The 72-h MgA correlated most highly with 0-24 h urine MgA value alone (ρ = 0.95, P < 0.001) or the mean of the 0-24 h urine and the 3-h (ρ = 0.93, P < 0.001) or 5-h (ρ = 0.96, P < 0.001) serum MgA values. In cohort 2, Bland-Altman bias was lowest (-0.003, P = 0.82) using means of the 0-24 h urine and 3-h serum MgA values. We conclude that means of 0-24 h urine and 3-h serum MgA provide a reasonable estimate of 72-h MgA. However, if researchers seek to identify small changes in MgA, we recommend a 3-d urine or extended stool collection. PMID:24500940

  7. Isotope Concentrations from 24-h Urine and 3-h Serum Samples Can Be Used to Measure Intestinal Magnesium Absorption in Postmenopausal Women123

    PubMed Central

    Hansen, Karen E.; Nabak, Andrea C.; Johnson, Rachael Erin; Marvdashti, Sheeva; Keuler, Nicholas S.; Shafer, Martin M.; Abrams, Steven A.

    2014-01-01

    Studies suggest a link between magnesium status and osteoporosis. One barrier to more conclusive research on the potential relation is measuring intestinal magnesium absorption (MgA), which requires the use of stable isotopes and a ≥6-d stool or 3-d urine collection. We evaluated alternative methods of measuring MgA. We administered 2 stable magnesium isotopes to 15 postmenopausal women (cohort 1) aged 62 ± 8 y with a dietary magnesium intake of 345 ± 72 mg/d. Participants fasted from 1200 h to 0700 h and then consumed breakfast with ∼23 mg of oral 26Mg and ∼11 mg of i.v. 25Mg. We measured magnesium isotope concentrations in 72-h urine, spot urine (36, 48, 60, and 72 h), and spot serum (1, 3, and 5 h) samples collected after isotope dosing. We calculated MgA using the dose-corrected fraction of isotope concentrations from the 72-h urine collection. We validated new methods in 10 postmenopausal women (cohort 2) aged 59 ± 5 y with a dietary magnesium intake of 325 ± 122 mg/d. In cohort 1, MgA based on the 72-h urine collection was 0.28 ± 0.08. The 72-h MgA correlated most highly with 0–24 h urine MgA value alone (ρ = 0.95, P < 0.001) or the mean of the 0–24 h urine and the 3-h (ρ = 0.93, P < 0.001) or 5-h (ρ = 0.96, P < 0.001) serum MgA values. In cohort 2, Bland-Altman bias was lowest (−0.003, P = 0.82) using means of the 0–24 h urine and 3-h serum MgA values. We conclude that means of 0–24 h urine and 3-h serum MgA provide a reasonable estimate of 72-h MgA. However, if researchers seek to identify small changes in MgA, we recommend a 3-d urine or extended stool collection. This trial was registered at clinicaltrials.gov as NCT01593501. PMID:24500940

  8. Determination of organophosphate diesters in urine samples by a high-sensitivity method based on ultra high pressure liquid chromatography-triple quadrupole-mass spectrometry.

    PubMed

    Su, Guanyong; Letcher, Robert J; Yu, Hongxia

    2015-12-24

    Organophosphate (OP) diesters in urine samples have potential use as biomarkers of organism exposure to environmentally relevant OP triester precursors and in particular OP triester flame retardants. This present study developed a quantitatively sensitive ultra high pressure liquid chromatography (UHPLC-MS) based method for urine and the determination of OP diesters (i.e. diphenyl phosphate (DPHP), bis(2-chloroethyl) phosphate (BCEP), bis(2-chloroisopropyl) phosphate (BDCIPP), di-n-butyl phosphate (DNBP), di(2-ethylhexyl) phosphate (DEHP), bis(1-chloro-2-propyl) phosphate (BCIPP), and bis(2-butoxyethyl) phosphate (BBOEP)). Fortified with the 7 OP diesters, 1mL of human urine sample was cleaned up using weak anion exchange solid phase extraction and eluted with high ionic strength ammonium acetate buffer. Subsequently, 4 non-chlorinated OP diesters were directly determined using UHPLC-electrospray(-)-triple quadrupole-MS (UHPLC-ESI(-)-QqQ-MS), and UHPLC-ESI(+)-QqQ-MS was used for determination of 3 chlorinated OP diesters after methylation using diazomethane. Recovery efficiencies of OP diesters ranged from 88 to 160% at three spiking levels (0.4, 2 and 10ng/mL urine). Matrix effects (MEs) and method limits of quantification (MLOQs) were 15-134% and 0.10-0.32ng/mL urine, respectively. Concentrations of OP diesters in n=12 urine samples (from 4 Canadian residents, 2014) varied as follows, nd-<0.28 (DNBP), nd-1.29 (DPHP), nd-<0.28 (DEHP), <0.16-12.33 (BCEP), nd-1.17 (BCDIPP) and nd-0.68ng/mL (BCIPP). PMID:26686560

  9. Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program

    SciTech Connect

    Antonio, Cheryl L.; Rivard, James W.

    2009-11-01

    During the decommissioning and maintenance of some of the facilities at the U.S. Department of Energy Hanford Site in Washington State, workers have potential for a 90Sr intake. However, because of worldwide radioactive fallout, 90Sr is present in our environment, and can be detectable in routine urine bioassay samples. It is important for the Hanford Site bioassay program to discern an occupational intake from a non-occupational environmental one. A detailed study of the background 90Sr in the urine of unexposed Hanford workers was performed. A survey of the Hanford Site bioassay database found 128 Hanford workers who were hired between 1997 and 2002 and who had a very low potential for an occupational exposure prior to the baseline strontium urinalysis. Each urinalysis sample represented excretion during an approximate 24-hr period. The arithmetic mean value for the 128 pre-exposure baselines was 3.6 ± 5.1 mBq d-1. The 90Sr activities in urine varied from -12 to 20 mBq. The 99th percentile result was 16.4 mBqd-1, which was interpreted to mean that 1% of Hanford workers not occupationally exposed to strontium might exceed 16.4 mBq d-1.

  10. DETERMINATION OF RACTOPAMINE IN CATTLE AND SHEEP URINE SAMPLES USING AN OPTICAL BIOSENSOR ANALYSIS:COMPARATIVE STUDY WITH HPLC AND ELISA.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A biosensor method, using the surface plasmon resonance (SPR) principle, was developed for the determination of ractopamine in cattle and sheep urine. A monoclonal antibody was used to compete with ractopamine in the sample and ractopamine immobilized on the sensor chip. Addition of bovine serum a...

  11. Examining the Relationship between Gender and Drug-Using Behaviors in Adolescents: The Use of Diagnostic Assessments and Biochemical Analyses of Urine Samples.

    ERIC Educational Resources Information Center

    James, William H.; Moore, David D.

    1999-01-01

    Examines the relationship between gender and drug use among adolescents using diagnostic assessments and biochemical analyses of urine samples. Statistical significance was found in the relationship between gender and marijuana use. The study confirms that more research is needed in this area. (Author/MKA)

  12. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    PubMed

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies. PMID:23467705

  13. [Position statement. Protein/creatinine in a randomly obtained urine sample in the diagnosis of proteinuria in pregnant patients with arterial hypertension].

    PubMed

    2012-01-01

    Leaños Miranda and collaborators published that the measurement of protein/creatinine ratio in a single random urine sample is a reliable indicator of significant proteinuria and may be reasonably used as alternative to the 24-hours urine collection method as a diagnostic criteria for urinary protein, and it is also a criterion for identifying the disease severity. This leads us to present this successful result of the investigation as a position statement in the care of pregnant women with hypertension. PMID:23282273

  14. Intra individual variability in markers of proteinuria for normal subjects and those with cadmium induced renal dysfunction: interpretation of results from untimed, random urine samples.

    PubMed

    Howard J Mason Alison J Stevenson Nerys Williams Michael Morgan

    1999-01-01

    The project aimed to help interpretation of urinary protein measurements, namely -2-microglobulin, retinol-binding protein, albumin and total protein in untimed, random urine samples as indicating significant changes in renal tubular reabsorption and glomerular permeability in an individual. A standard methodology used in clinical laboratory medicine was applied to calculate the intra-individual biological variation for these analytes. This parameter in conjunction with a laboratory's analytical variation allows definition of uncertainty about a single urine protein measurement, significant changes above normal variation in serial measurements within an individual and a defined level of maximum acceptable analytical imprecision. Repeat urine samples were obtained over a period of one week from a group of cadmium-exposed workers, 90% of whom had long-term tubular proteinuria, and a group of five unexposed volunteers with normal renal function. Dilute samples defined as having creatinines less than 3 mmol l-1 were excluded, as were urines with pH less than 5.5 for -2-microglobulin. Samples were analysed twice after randomisation in large batches. There was no evidence of any diurnal variation in the four protein measurements from samples collected between early morning and 16:00 hours. Creatinine or specific gravity correction of urine results for all four proteins only marginally reduced the uncertainty associated with an individual measurement asreflecting the true excretion value. For those subjects with defined tubular proteinuria, variability in retinol-binding protein excretion was less than that for -2- microglobulin. About 30% of the samples had urine pHs of 5.5 or less where -2- microglobulin degradation occurs. Using our laboratory analytical precision the minimum changes between serial creatinine-corrected measurements that are needed to be considered statistically significant (p < 0.05) is 110% for retinol-binding protein, 177% for -2-microglobulin, 70

  15. Mercury determination in urine samples by gold nanostructured screen-printed carbon electrodes after vortex-assisted ionic liquid dispersive liquid-liquid microextraction.

    PubMed

    Fernández, Elena; Vidal, Lorena; Costa-García, Agustín; Canals, Antonio

    2016-04-01

    A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid-liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L(-1) of mercury. Standard addition calibration curves using standards between 0 and 20 μg L(-1) gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L(-1), and from 1.1 to 1.3 μg L(-1), respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10-20 μg L(-1)). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L(-1) as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%). PMID:26995639

  16. Spectrophotometric determination of pico-molar level of hydrazine by using Alizarin red in water and urine samples.

    PubMed

    Arulraj, Abraham Daniel; Vijayan, Muthunanthevar; Vasantha, Vairathevar Sivasamy

    2015-09-01

    In this paper, very simple and rapid sensor has been developed for the spectrophotometric determination of pico-molar level of hydrazine using Alizarin red. There was a decrease of optical intensity of the probe in the presence of hydrazine. The LOD is calculated from the linear graph between 5-100 pM as 0.66 pM of hydrazine which is well below the risk level proposed by Agency for Toxic Substance and Disease Registry. The probe selectivity for the detection of hydrazine was tested in the presence of commonly encountered metal ions and anions. The calibration curves showed good linearity for working ranges from 5-100 pM and 0.5-40 mM respectively, with R(2)=0.9911 and 0.9744, indicate the validity of the Beer-Lambert law. The binding constant and the free energy change values are determined by the Benesi-Hildebrand method. Determination of hydrazine in environmental water and human urine samples are successfully performed by the proposed method with the recovery of 100%. PMID:25911160

  17. Aptasensor based on fluorescence resonance energy transfer for the analysis of adenosine in urine samples of lung cancer patients.

    PubMed

    Hashemian, Zahra; Khayamian, Taghi; Saraji, Mohammad; Shirani, Marziyeh Poshteh

    2016-05-15

    A new aptasensor was designed for the analysis of adenosine based on fluorescence resonance energy transfer (FRET) between CdS quantum dot (QDs) as a donor and polypyrrole (Ppy) as an acceptor. The QDs were covalently bonded to anti-adenosine aptamer where its fluorescence was quenched by Ppy. When Ppy was replaced by adenosine, the fluorescence of QDs was restored and its intensity was proportional to the adenosine concentration. Under the optimized conditions, a linear range was found to be 23-146 nM with a detection limit of 9.3 nM. The method was used for analysis of adenosine in urine samples of lung cancer patients and its accuracy was evaluated by comparison of the results of the proposed method with the standard method of HPLC-UV. Furthermore, the interactions of adenosine molecules with the aptamer were investigated using molecular modeling, including molecular dynamic simulations (MDS). The results demonstrated that each G-quadruplex aptamer can capture two adenosine molecules. PMID:26722763

  18. Spectrophotometric determination of pico-molar level of hydrazine by using Alizarin red in water and urine samples

    NASA Astrophysics Data System (ADS)

    Arulraj, Abraham Daniel; Vijayan, Muthunanthevar; Vasantha, Vairathevar Sivasamy

    2015-09-01

    In this paper, very simple and rapid sensor has been developed for the spectrophotometric determination of pico-molar level of hydrazine using Alizarin red. There was a decrease of optical intensity of the probe in the presence of hydrazine. The LOD is calculated from the linear graph between 5-100 pM as 0.66 pM of hydrazine which is well below the risk level proposed by Agency for Toxic Substance and Disease Registry. The probe selectivity for the detection of hydrazine was tested in the presence of commonly encountered metal ions and anions. The calibration curves showed good linearity for working ranges from 5-100 pM and 0.5-40 mM respectively, with R2 = 0.9911 and 0.9744, indicate the validity of the Beer-Lambert law. The binding constant and the free energy change values are determined by the Benesi-Hildebrand method. Determination of hydrazine in environmental water and human urine samples are successfully performed by the proposed method with the recovery of 100%.

  19. Comparative Study of Seven Commercial Kits for Human DNA Extraction from Urine Samples Suitable for DNA Biomarker-Based Public Health Studies

    PubMed Central

    El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.

    2014-01-01

    Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790

  20. Optimization of the β LACTA test for the detection of extended-spectrum-β-lactamase-producing bacteria directly in urine samples.

    PubMed

    Amzalag, Jonas; Mizrahi, Assaf; Naouri, Diane; Nguyen, Jean Claude; Ganansia, Olivier; Le Monnier, Alban

    2016-09-01

    The β LACTA™ test (BLT) is a chromogenic test detecting resistance to third-generation cephalosporins on bacterial colonies. Some studies have shown that this test can be used directly in urine samples. The aim of this study was to determine the optimal conditions of use of this test in order to detect the ESBL-producing bacteria directly in urine samples. During a 4-months period, a total of 365 consecutive urine samples were tested with the BLT using the recommendation of the manufacturer. We isolated 56 ESBL-producing bacteria and 17 AmpC-overproducing bacteria. ESBL- and/or AmpC β-lactamase-producing bacteria isolates were systematically characterized by disc diffusion antibiotic susceptibility testing interpreted according to the guidelines of EUCAST. The sensitivity and the specificity for 3GC-resistance detection, regardless the mechanism of resistance, were, respectively, 60.3% and 100%, whereas for ESBL detection, it was, respectively, 75.4% and 99.7%. We applied then modification of the initial protocol considering urines with a bacteriuria >1000/μL, a reading time at 30 min and considering any change of the initial colour as positive. The overall sensitivity was 81% and the sensitivity for ESBL-detection raised to 95.7%. PMID:27225534

  1. Will Women Diagnosed with Breast Cancer Provide Biological Samples for Research Purposes?

    PubMed Central

    Harris, Shelley A.; Boucher, Beatrice A.; Cotterchio, Michelle

    2015-01-01

    Background Little is known about the response rates for biological sample donation and attitudes towards control recruitment, especially in younger women. The goals of this pilot study were to determine in women recently diagnosed with breast cancer, the proportion of cases willing to provide biological samples and for purposes of control recruitment, contact information for friends or colleagues. Methods A population-based sample of breast cancer cases (n = 417, 25-74 years) was recruited from the Ontario Cancer Registry in 2010 and self-administered questionnaires were completed to determine willingness to provide samples (spot or 24-hr urine, saliva, blood) and contact information for friends/colleagues for control recruitment. Using Χ2 analyses of contingency tables we evaluated if these proportions varied by age group (<45 and 45+) and other factors such as ethnicity, education, income, body mass index (BMI), smoking status and alcohol consumption. Results Cases were willing to provide blood samples, by visiting a clinic (62%) or by having a nurse visit the home (61%). Moreover, they would provide saliva (73%), and morning or 24-hr urine samples (66% and 52%). Younger cases (≤45) were 3 times (OR) more likely more than older cases to agree to collect morning urine (95% CI: 1.15-8.35). Only 26% of cases indicated they would provide contact information of friends or work colleagues to act as controls. Educated cases were more likely to agree to provide samples, and cases who consumed alcohol were more willing to provide contact information. Ethnicity, income, BMI and smoking had little effect on response rates. Conclusions Reasonable response rates for biological sample collection should be expected in future case controls studies in younger women, but other methods of control selection must be devised. PMID:26061089

  2. Urine concentration test

    MedlinePlus

    ... or osmolality, your provider will send your urine sample to a lab. If needed, your provider may ask you to collect your urine at home over 24 hours . Your provider will tell you how to do this. Follow instructions exactly so that the results are accurate.

  3. GC-MS and LC-MS analysis of nerve agents in body fluids: intra-laboratory verification test using spiked plasma and urine samples.

    PubMed

    Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz

    2010-05-15

    The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). PMID:20061191

  4. Method for determination of neptunium in large-sized urine samples using manganese dioxide coprecipitation and 242Pu as yield tracer.

    PubMed

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-02-01

    A novel method for bioassay of large volumes of human urine samples using manganese dioxide coprecipitation for preconcentration was developed for rapid determination of (237)Np. (242)Pu was utilized as a nonisotopic tracer to monitor the chemical yield of (237)Np. A sequential injection extraction chromatographic (SI-EC) system coupled with inductively coupled plasma mass spectrometry (ICPMS) was exploited to facilitate the rapid column separation and quantification. The analytical results demonstrated satisfactory performance of the MnO(2) coprecipitation as indicated by the high chemical yields close to 100% and high separation capacity of processing up to 5 L of human urine samples. The MnO(2) coprecipitation process is simple and straightforward in which a batch (8-12) of samples can be pretreated within 4 h (i.e., <0.5 h/sample). In connection with the automated column separation and ICPMS quantification, which takes less than 1.5 h in total, the overall analytical time was on average less than 2 h for each sample. The high effectiveness and sample throughput make the developed method well suited for urine bioassay of (237)Np in routine monitoring of occupationally internal radiation exposure and rapid analysis of neptunium contamination level for emergency preparedness. PMID:23252688

  5. Determination of total iodine in serum and urine samples by ion chromatography with pulsed amperometric detection - studies on analyte loss, optimization of sample preparation procedures, and validation of analytical method.

    PubMed

    Błażewicz, Anna; Klatka, Maria; Dolliver, Wojciech; Kocjan, Ryszard

    2014-07-01

    A fast, accurate and precise ion chromatography method with pulsed amperometric detection was applied to evaluate a variety of parameters affecting the determination of total iodine in serum and urine of 81 subjects, including 56 obese and 25 healthy Polish children. The sample pretreatment methods were carried out in a closed system and with the assistance of microwaves. Both alkaline and acidic digestion procedures were developed and optimized to find the simplest combination of reagents and the appropriate parameters for digestion that would allow for the fastest, least time consuming and most cost-effective way of analysis. A good correlation between the certified and the measured concentrations was achieved. The best recoveries (96.8% for urine and 98.8% for serum samples) were achieved using 1ml of 25% tetramethylammonium hydroxide solution within 6min for 0.1ml of serum/urine samples. Using 0.5ml of 65% nitric acid solution the best recovery (95.3%) was obtained when 7min of effective digestion time was used. Freeze-thaw stability and long-term stability were checked. After 24 weeks 14.7% loss of iodine in urine, and 10.9% in serum samples occurred. For urine samples, better correlation (R(2)=0.9891) of various sample preparation procedures (alkaline digestion and application of OnGuard RP cartidges) was obtained. Significantly lower iodide content was found in samples taken from obese children. Serum iodine content in obese children was markedly variable in comparison with the healthy group, whereas the difference was less evident when urine samples were analyzed. The mean content in serum was 59.12±8.86μg/L, and in urine 98.26±25.93 for obese children when samples were prepared by the use of optimized alkaline digestion reinforced by microwaves. In healthy children the mean content in serum was 82.58±6.01μg/L, and in urine 145.76±31.44μg/L. PMID:24911549

  6. Immunoelectrophoresis - urine

    MedlinePlus

    ... in the urine can result from: Amyloidosis Leukemia Multiple myeloma Kidney disorders such as IgA nephropathy or IgM ... CLL) IgA nephropathy Immunoelectrophoresis - blood Macroglobulinemia of Waldenstrom Multiple myeloma Protein electrophoresis - urine Protein urine test Urinalysis Update ...

  7. Extended-spectrum β-lactamase (ESBL) detection directly from urine samples with the rapid isothermal amplification-based eazyplex® SuperBug CRE assay: Proof of concept.

    PubMed

    Hinić, V; Ziegler, J; Straub, C; Goldenberger, D; Frei, R

    2015-12-01

    A commercially available assay (eazyplex® SuperBug CRE) detecting the most common carbapenemase and ESBL types was evaluated directly on 50 urine samples. Eazyplex® correctly detected ESBL-encoding genes in all 30 urine samples with confirmed ESBL production (sensitivity 100%). Two specimens showed invalid and one specimen false-positive results (specificity 97.9%). PMID:26506282

  8. Rapid determination of letrozole, citalopram and their metabolites by high performance liquid chromatography-fluorescence detection in urine: Method validation and application to real samples.

    PubMed

    Rodríguez, J; Castañeda, G; Muñoz, L

    2013-01-15

    This work reports the validation of a high precision and accuracy method for the simultaneous determination of letrozole, citalopram and their metabolites in urine by high performance liquid chromatography with fluorescence detection. Dilution (urine:mobile phase, 1:2, v/v) was the only sample preparation step. The separation was carried out in a Kromasil C(18) (150mm×4.6mm) column, and the mobile phase was phosphate buffer 80mM (pH 3.0) and acetonitrile (65:35, v/v) at a flow rate of 1.0mL/min. The analytes were detected at 295nm after excitation at 230nm. Linearity was observed in the range of 1.0-1000ng/mL for letrozole and its metabolite and 2.5-1000ng/mL for citalopram and their metabolites, with limits of detection and quantification between 0.09-1.0 and 0.27-1.65ng/mL, respectively. The precisions were satisfactory with RSDs between 0.17 and 5.71%. The accuracy was studied by spiking three urines from healthy female volunteers, and the recoveries were from 85 to 103%. The method was applied to urine samples from women under treatment for breast cancer and depression diseases. PMID:23262245

  9. Temporal trends in bisphenol A exposure in the United States from 2003-2012 and factors associated with BPA exposure: Spot samples and urine dilution complicate data interpretation.

    PubMed

    LaKind, Judy S; Naiman, Daniel Q

    2015-10-01

    Nationally representative data on urinary levels of BPA and its metabolites in the United States from the 2003-2004 to 2011-2012 National Health and Nutrition Examination Surveys (NHANES) were used to estimate daily BPA intakes and examine temporal trends. Additionally, NHANES data on lifestyle/demographic/dietary factors previously reported to be associated with BPA exposures were examined to assess the resiliency of the reported associations (whether the association is maintained across the five surveys). Finally, various approaches for addressing issues with the use of BPA concentration data from spot urine samples were examined for their effect on trends and associations. Three approaches were assessed here: (i) use of generic literature-based 24-h urine excretion volumes, (ii) use of creatinine adjustments, and (iii) use of individual urine flow rate data from NHANES. Based on 2011-2012 NHANES urinary BPA data and assumptions described in this paper, the median daily intake for the overall population is approximately 25 ng/kg day; median intake estimates were approximately two to three orders of magnitude below current health-based guidance values. Estimates of daily BPA intake have decreased significantly compared to those from the 2003-2004 NHANES. Estimates of associations between lifestyle/demographic/dietary factors and BPA exposure revealed inconsistencies related to both NHANES survey year and the three approaches listed above; these results demonstrate the difficulties in interpreting urinary BPA data, despite efforts to account for urine dilution and translation of spot sample data to 24-h data. The results further underscore the importance of continued research on how to best utilize urinary measures of environmental chemicals in exposure research. Until a consensus is achieved regarding the best biomonitoring approaches for assessing exposures to short-lived chemicals using urine samples, research on factors associated with BPA exposures should

  10. Urine Monitoring System

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Cibuzar, Branelle R.

    2009-01-01

    The Urine Monitoring System (UMS) is a system designed to collect an individual crewmember's void, gently separate urine from air, accurately measure void volume, allow for void sample acquisition, and discharge remaining urine into the Waste Collector Subsystem (WCS) onboard the International Space Station. The Urine Monitoring System (UMS) is a successor design to the existing Space Shuttle system and will resolve anomalies such as: liquid carry-over, inaccurate void volume measurements, and cross contamination in void samples. The crew will perform an evaluation of airflow at the ISS UMS urinal hose interface, a calibration evaluation, and a full user interface evaluation. o The UMS can be used to facilitate non-invasive methods for monitoring crew health, evaluation of countermeasures, and implementation of a variety of biomedical research protocols on future exploration missions.

  11. Single-drop microextraction combined in-line with capillary electrophoresis for the determination of nonsteroidal anti-inflammatory drugs in urine samples.

    PubMed

    García-Vázquez, Alejandro; Borrull, Francesc; Calull, Marta; Aguilar, Carme

    2016-01-01

    This study describes a method to determine nonsteroidal anti-inflammatory drugs (NSAIDs) in urine samples based on the use of single-drop microextraction (SDME) in a three-phase design as a preconcentration technique coupled in-line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 μg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27-fold for ketoprofen, 14-fold for diclofenac, 12-fold for ibuprofen, and 44-fold naproxen. Samples were analyzed applying the SDME-CE method and the obtained results presented satisfactory recovery values (82-115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment. PMID:26530782

  12. Detection of diazepam in urine, hair and preserved oral fluid samples with LC-MS-MS after single and repeated administration of Myolastan and Valium.

    PubMed

    Laloup, Marleen; Fernandez, Maria Del Mar Ramirez; Wood, Michelle; Maes, Viviane; De Boeck, Gert; Vanbeckevoort, Yvan; Samyn, Nele

    2007-08-01

    Sedative agents are used to facilitate sexual assault due to their ability to render the victim passive, submissive and unable to resist. The primary pharmacological effect of the benzodiazepine tetrazepam is muscle relaxation, whereas the benzodiazepine diazepam acts on the central nervous system (CNS) exerting mainly sedation effects. Therefore, contrary to tetrazepam, diazepam is an often-abused drug, which can potentially be used as a date-rape drug. In this study, we describe the detection of low amounts of diazepam in Myolastan (Sanofi-Synthelabo S.A., Brussels, Belgium) and Epsipam (Will-Pharma, Wavre, Belgium) 50 mg tablet preparations by LC-MS-MS, GC-FID and HPLC-DAD. Considering the important forensic implication of this finding, a study was conducted with volunteers receiving a single or repeated dosage of Myolastan. Urine, hair and preserved oral fluid samples were analysed using a previously described sensitive and specific LC-MS-MS detection method allowing for the simultaneous quantification of tetrazepam, diazepam, nordiazepam, oxazepam and temazepam. This study demonstrates that diazepam can be observed in urine samples even after a single dose of Myolastan. In addition, maintaining therapy for 1 week results in the detection of both diazepam and nordiazepam in urine samples and of diazepam in the first hair segment. Importantly, comparing urine and hair samples after a single intake of diazepam versus the single and 1 week administration of Myolastan shows that the possible metabolic conversion of tetrazepam to diazepam is a more plausible explanation for the detection of diazepam in biological samples after the intake of Myolastan. As such, these results reveal that the presence of diazepam and/or nordiazepam in biological samples from alleged drug-facilitated assault cases should be interpreted with care. PMID:17468852

  13. Direct identification of bacteria in urine samples by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and relevance of defensins as interfering factors.

    PubMed

    Köhling, Hedda Luise; Bittner, Anna; Müller, Karl-Dieter; Buer, Jan; Becker, Markus; Rübben, Herbert; Rettenmeier, Albert Wolfgang; Mosel, Frank

    2012-03-01

    Standard methods for the identification of uropathogens that are based on the determination of metabolic activity require cultivation on agar plates, which often takes more than 1 day. If microbial growth on agar plates is slow, or if metabolic activity is impaired by adverse interactions resulting from the patient's condition or from medical treatment, the application of standard methods may lead to delayed or erroneous identification of bacteria. In recent studies, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has proven to be able to rapidly identify bacteria obtained from cultures. We tested the applicability of this analytical technique for the rapid identification of bacteria collected directly from urine samples and compared the results with those of conventional identification methods, such as the Vitek system, the MicroScan WalkAway system and the API system, and in some cases with the gas chromatographic determination of the bacterial long-chain fatty acid pattern. We analysed a total of 107 urine samples with bacterial counts ranging from 10(2) to ≥10(5) c.f.u. ml(-1). Mass spectrometric identification of bacteria was accomplished for 62 of these samples. In the mass spectra obtained from 40 of the 45 urine samples for which no identification result was achieved, a triplet of very intense peaks corresponding to the human α-defensins 1, 2 and 3 occurred at m/z values of around 3440 Da. This signal suppressed the intensity of the bacterial protein peaks and thus impaired database matching. Our results show that MALDI-TOF MS allows the reliable direct identification of bacteria in urine samples at concentrations as low as 10(3) c.f.u. ml(-1). In a subset of samples, human defensins may occur and impair the mass spectrometric identification of bacteria. PMID:22275503

  14. Fission track analysis of plutonium in small specimens of biological material: Ultrasensitive analysis for sup 239 Pu in 50 urine samples from the Marshall Islands furnished by Brookhaven National Laboratory

    SciTech Connect

    Wrenn, M.E.; Singh, N.P.; Xue, Ying-Hua.

    1990-11-20

    A neutron induced fission track method was successfully developed for assaying {sup 239}Pu in human urine. The technique involves means to remove potentially interfering natural uranium from the sample and reagents. The method was applied to 50 urine samples including an unknown number of spikes and controls from the Marshall Islands. 49 samples were successfully analyzed. The mean activity for the 47 samples which were not positive for {sup 239}Pu did not differ significantly from the mean for our control samples, which consisted of urines collected from six young adult Utah residents. 2 figs., 12 tabs.

  15. Antibiotic exposure in a low-income country: screening urine samples for presence of antibiotics and antibiotic resistance in coagulase negative staphylococcal contaminants.

    PubMed

    Lerbech, Anne Mette; Opintan, Japheth A; Bekoe, Samuel Oppong; Ahiabu, Mary-Anne; Tersbøl, Britt Pinkowski; Hansen, Martin; Brightson, Kennedy T C; Ametepeh, Samuel; Frimodt-Møller, Niels; Styrishave, Bjarne

    2014-01-01

    Development of antimicrobial resistance has been assigned to excess and misuse of antimicrobial agents. Staphylococci are part of the normal flora but are also potential pathogens that have become essentially resistant to many known antibiotics. Resistances in coagulase negative staphylococci (CoNS) are suggested to evolve due to positive selective pressure following antibiotic treatment. This study investigated the presence of the nine most commonly used antimicrobial agents in human urine from outpatients in two hospitals in Ghana in relation to CoNS resistance. Urine and CoNS were sampled (n = 246 and n = 96 respectively) from patients in two hospitals in Ghana. CoNS were identified using Gram staining, coagulase test, and MALDI-TOF/MS, and the antimicrobial susceptibility to 12 commonly used antimicrobials was determined by disk diffusion. Moreover an analytical method was developed for the determination of the nine most commonly used antimicrobial agents in Ghana by using solid-phase extraction in combination with HPLC-MS/MS using electron spray ionization. The highest frequency of resistance to CoNS was observed for penicillin V (98%), trimethoprim (67%), and tetracycline (63%). S. haemolyticus was the most common isolate (75%), followed by S. epidermidis (13%) and S. hominis (6%). S. haemolyticus was also the species displaying the highest resistance prevalence (82%). 69% of the isolated CoNS were multiple drug resistant (≧ 4 antibiotics) and 45% of the CoNS were methicillin resistant. Antimicrobial agents were detected in 64% of the analysed urine samples (n = 121) where the most frequently detected antimicrobials were ciprofloxacin (30%), trimethoprim (27%), and metronidazole (17%). The major findings of this study was that the prevalence of detected antimicrobials in urine was more frequent than the use reported by the patients and the prevalence of resistant S. haemolyticus was more frequent than other resistant CoNS species when antimicrobial agents

  16. Antibiotic Exposure in a Low-Income Country: Screening Urine Samples for Presence of Antibiotics and Antibiotic Resistance in Coagulase Negative Staphylococcal Contaminants

    PubMed Central

    Lerbech, Anne Mette; Opintan, Japheth A.; Bekoe, Samuel Oppong; Ahiabu, Mary-Anne; Tersbøl, Britt Pinkowski; Hansen, Martin; Brightson, Kennedy T. C.; Ametepeh, Samuel; Frimodt-Møller, Niels; Styrishave, Bjarne

    2014-01-01

    Development of antimicrobial resistance has been assigned to excess and misuse of antimicrobial agents. Staphylococci are part of the normal flora but are also potential pathogens that have become essentially resistant to many known antibiotics. Resistances in coagulase negative staphylococci (CoNS) are suggested to evolve due to positive selective pressure following antibiotic treatment. This study investigated the presence of the nine most commonly used antimicrobial agents in human urine from outpatients in two hospitals in Ghana in relation to CoNS resistance. Urine and CoNS were sampled (n = 246 and n = 96 respectively) from patients in two hospitals in Ghana. CoNS were identified using Gram staining, coagulase test, and MALDI-TOF/MS, and the antimicrobial susceptibility to 12 commonly used antimicrobials was determined by disk diffusion. Moreover an analytical method was developed for the determination of the nine most commonly used antimicrobial agents in Ghana by using solid-phase extraction in combination with HPLC-MS/MS using electron spray ionization. The highest frequency of resistance to CoNS was observed for penicillin V (98%), trimethoprim (67%), and tetracycline (63%). S. haemolyticus was the most common isolate (75%), followed by S. epidermidis (13%) and S. hominis (6%). S. haemolyticus was also the species displaying the highest resistance prevalence (82%). 69% of the isolated CoNS were multiple drug resistant (≧4 antibiotics) and 45% of the CoNS were methicillin resistant. Antimicrobial agents were detected in 64% of the analysed urine samples (n = 121) where the most frequently detected antimicrobials were ciprofloxacin (30%), trimethoprim (27%), and metronidazole (17%). The major findings of this study was that the prevalence of detected antimicrobials in urine was more frequent than the use reported by the patients and the prevalence of resistant S. haemolyticus was more frequent than other resistant CoNS species when

  17. Automated extraction of 11-nor-delta9-tetrahydrocannabinol carboxylic acid from urine samples using the ASPEC XL solid-phase extraction system.

    PubMed

    Langen, M C; de Bijl, G A; Egberts, A C

    2000-09-01

    The analysis of 11-nor-delta9-tetrahydrocannabinol-carboxylic acid (THCCOOH, the major metabolite of cannabis) in urine with gas chromatography and mass spectrometry (GC-MS) and solid-phase extraction (SPE) sample preparation is well documented. Automated SPE sample preparation of THCCOOH in urine, although potentially advantageous, is to our knowledge poorly investigated. The objective of the present study was to develop and validate an automated SPE sample-preparation step using ASPEC XL suited for GC-MS confirmation analysis of THCCOOH in urine drug control. The recoveries showed that it was not possible to transfer the protocol for the manual SPE procedure with the vacuum manifold to the ASPEC XL without loss of recovery. Making the sample more lipophilic by adding 1 mL 2-propanol after hydrolysis to the urine sample in order to overcome the problem of surface adsorption of THCCOOH led to an extraction efficiency (77%) comparable to that reached with the vacuum manifold (84%). The reproducibility of the automated SPE procedure was better (coefficient of variation 5%) than that of the manual procedure (coefficient of variation 12%). The limit of detection was 1 ng/mL, and the limit of quantitation was 4 ng/mL. Precision at the 12.5-ng/mL level was as follows: mean, 12.4 and coefficient of variation, 3.0%. Potential carryover was evaluated, but a carryover effect could not be detected. It was concluded that the proposed method is suited for GC-MS confirmation urinalysis of THCCOOH for prisons and detoxification centers. PMID:10999349

  18. Fully automatic sample treatment by integration of microextraction by packed sorbents into commercial capillary electrophoresis-mass spectrometry equipment: application to the determination of fluoroquinolones in urine.

    PubMed

    Morales-Cid, Gabriel; Cárdenas, Soledad; Simonet, Bartolomé M; Valcárcel, Miguel

    2009-04-15

    This paper describes a new and innovative way to integrate microextraction by packed sorbents (MEPS) into commercial CE equipment. The suggested integration allows the automatic sample cleanup and preconcentration requiring only a few microliters of sample and no additional hardware and software. The MEPS was integrated in the outlet region of a commercial CE equipment cartridge in order to provide easy manipulation and exchange. The robustness of the proposed integration was demonstrated by the design and use of a (MEPS)-nonaqueous capillary electrophoresis (NACE)-MS method used to determine fluoroquinolones "FQs" (namely, ofloxacin, marbofloxacin, enrofloxacin, danofloxacin, and difloxacin) in urine. The method allows the analysis of micrograms per liter of FQs to be carried out with only 48 microL of urine sample. The obtained LODs were in the range 6.3-10.6 microg/L. An analysis of spiked urine samples was used to validate the method. Absolute recoveries were in the range of 71-109% while the precision expressed as repetitivity of peak area was lower than 5.9%. PMID:19284777

  19. Strategy for NMR metabolomic analysis of urine in mouse models of obesity--from sample collection to interpretation of acquired data.

    PubMed

    Pelantová, Helena; Bugáňová, Martina; Anýž, Jiří; Železná, Blanka; Maletínská, Lenka; Novák, Daniel; Haluzík, Martin; Kuzma, Marek

    2015-11-10

    The mouse model of monosodium glutamate induced obesity was used to examine and consequently optimize the strategy for analysis of urine samples by NMR spectroscopy. A set of nineteen easily detectable metabolites typical in obesity-related studies was selected. The impact of urine collection protocol, choice of (1)H NMR pulse sequence, and finally the impact of the normalization method on the detected concentration of selected metabolites were investigated. We demonstrated the crucial effect of food intake and diurnal rhythms resulting in the choice of a 24-hour fasting collection protocol as the most convenient for tracking obesity-induced increased sensitivity to fasting. It was shown that the Carr-Purcell-Meiboom-Gill (CPMG) experiment is a better alternative to one-dimensional nuclear Overhauser enhancement spectroscopy (1D-NOESY) for NMR analysis of mouse urine due to its ability to filter undesirable signals of proteins naturally present in rodent urine. Normalization to total spectral area provided comparable outcomes as did normalization to creatinine or probabilistic quotient normalization in the CPMG-based model. The optimized approach was found to be beneficial mainly for low abundant metabolites rarely monitored due to their overlap by strong protein signals. PMID:26263053

  20. Complete Genome Sequence of Multidrug-Resistant Citrobacter freundii Strain P10159, Isolated from Urine Samples from a Patient with Esophageal Carcinoma

    PubMed Central

    Liu, Xiaodong; Huang, Yong; Xu, Xiaomeng; Zhao, Yachao; Sun, Qiang; Zhang, Zhiyi; Zhang, Xianglilan; Wu, Yi; Wang, Jie; Zhou, Dongsheng; An, Xiaoping; Pei, Guangqian; Wang, Yunfei; Mi, Zhiqiang

    2016-01-01

    Citrobacter freundii is an opportunistic pathogen that can cause diarrhea, septicemia, meningitis, and urinary tract infections. We report here the complete genome sequence of C. freundii strain P10159, isolated from urine samples from a patient in China with esophageal carcinoma. The genome has 5,080,321 bp and 4,768 coding sequences, with a G+C content of 51.7%. PMID:26893430

  1. Diagnostic Accuracy and Applicability of a PCR System for the Detection of Schistosoma mansoni DNA in Human Urine Samples from an Endemic Area

    PubMed Central

    Enk, Martin Johannes; Oliveira e Silva, Guilherme; Rodrigues, Nilton Barnabé

    2012-01-01

    Schistosomiasis caused by Schistosoma mansoni, one of the most neglected human parasitoses in Latin America and Africa, is routinely confirmed by microscopic visualization of eggs in stool. The main limitation of this diagnostic approach is its lack of sensitivity in detecting individual low worm burdens and consequently data on infection rates in low transmission settings are little reliable. According to the scientific literature, PCR assays are characterized by high sensitivity and specificity in detecting parasite DNA in biological samples. A simple and cost effective extraction method for DNA of Schistosoma mansoni from urine samples in combination with a conventional PCR assay was developed and applied in an endemic area. This urine based PCR system was tested for diagnostic accuracy among a population of a small village in an endemic area, comparing it to a reference test composed of three different parasitological techniques. The diagnostic parameters revealed a sensitivity of 100%, a specificity of 91.20%, positive and negative predictive values of 86.25% and 100%, respectively, and a test accuracy of 94.33%. Further statistical analysis showed a k index of 0.8806, indicating an excellent agreement between the reference test and the PCR system. Data obtained from the mouse model indicate the infection can be detected one week after cercariae penetration, opening a new perspective for early detection and patient management during this stage of the disease. The data indicate that this innovative PCR system provides a simple to handle and robust diagnostic tool for the detection of S. mansoni DNA from urine samples and a promising approach to overcome the diagnostic obstacles in low transmission settings. Furthermore the principals of this molecular technique, based on the examination of human urine samples may be useful for the diagnosis of other neglected tropical diseases that can be detected by trans-renal DNA. PMID:22701733

  2. Diagnostic accuracy and applicability of a PCR system for the detection of Schistosoma mansoni DNA in human urine samples from an endemic area.

    PubMed

    Enk, Martin Johannes; Oliveira e Silva, Guilherme; Rodrigues, Nilton Barnabé

    2012-01-01

    Schistosomiasis caused by Schistosoma mansoni, one of the most neglected human parasitoses in Latin America and Africa, is routinely confirmed by microscopic visualization of eggs in stool. The main limitation of this diagnostic approach is its lack of sensitivity in detecting individual low worm burdens and consequently data on infection rates in low transmission settings are little reliable. According to the scientific literature, PCR assays are characterized by high sensitivity and specificity in detecting parasite DNA in biological samples. A simple and cost effective extraction method for DNA of Schistosoma mansoni from urine samples in combination with a conventional PCR assay was developed and applied in an endemic area. This urine based PCR system was tested for diagnostic accuracy among a population of a small village in an endemic area, comparing it to a reference test composed of three different parasitological techniques. The diagnostic parameters revealed a sensitivity of 100%, a specificity of 91.20%, positive and negative predictive values of 86.25% and 100%, respectively, and a test accuracy of 94.33%. Further statistical analysis showed a k index of 0.8806, indicating an excellent agreement between the reference test and the PCR system. Data obtained from the mouse model indicate the infection can be detected one week after cercariae penetration, opening a new perspective for early detection and patient management during this stage of the disease. The data indicate that this innovative PCR system provides a simple to handle and robust diagnostic tool for the detection of S. mansoni DNA from urine samples and a promising approach to overcome the diagnostic obstacles in low transmission settings. Furthermore the principals of this molecular technique, based on the examination of human urine samples may be useful for the diagnosis of other neglected tropical diseases that can be detected by trans-renal DNA. PMID:22701733

  3. Jack Healy Remembers - Anecdotal Evidence for the Origin of the Approximate 24-hour Urine Sampling Protocol Used for Worker Bioassay Monitoring

    SciTech Connect

    Carbaugh, Eugene H.

    2008-10-01

    The origin of the approximate 24-hour urine sampling protocol used at Hanford for routine bioassay is attributed to an informal study done in the mid-1940s. While the actual data were never published and have been lost, anecdotal recollections by staff involved in the initial bioassay program design and administration suggest that the sampling protocol had a solid scientific basis. Numerous alternate methods for normalizing partial day samples to represent a total 24-hour collection have since been proposed and used, but no one method is obviously preferred.

  4. Determination of chemotherapeutic drugs in human urine by capillary electrophoresis with UV and fluorimetric detection using solid-supported liquid-liquid extraction for sample clean-up.

    PubMed

    Hurtado-Sánchez, María del Carmen; Acedo-Valenzuela, María Isabel; Durán-Merás, Isabel; Rodríguez-Cáceres, María Isabel

    2015-06-01

    Capillary electrophoresis was used for the rapid determination of three chemotherapeutic drugs employed to treat colorectal cancer: irinotecan, tegafur, and leucovorin, and their main metabolites (7-ethyl-10-hydroxycamptothecin and 5-fluorouracil), in human urine samples. A phosphate buffer (pH 11.34; 20 mM) was selected as the background electrolyte. A hydrodynamic injection (9 s, 30 mbar) was applied and the separation was carried out using a separation temperature and voltage of 25°C and 25 kV, respectively. A capillary with two detection windows for serial online UV and fluorescence detection was satisfactorily employed. A solid-supported liquid-liquid extraction procedure was optimized for the clean-up of the urine samples and the extraction of the analytes. Matrix effects were assessed and signal suppression was observed for three of the analytes, thus, matrix-matched calibration was used for compensating residual matrix effects on these analytes. The proposed method allows the separation and quantification of the chemotherapeutics in less than 6 min. Detection limits range between 0.01 and 0.30 mg/L. The method was satisfactorily applied to the determination of the target compounds in human urine samples, with recoveries of 92.4-107.7%. PMID:25820908

  5. Laboratory evaluation of a SpectraMax microplate reader and test strips for field measurement of creatinine in spot urine samples in the event of a radiological accident.

    PubMed

    Daka, Joseph N; Moodie, Gerry; Li, Chunsheng; Wilkins, Ruth; Kramer, Gary H

    2011-08-01

    The fear that terrorists might use radiological or nuclear (RN) devices to attack others is a new but growing phenomenon, arising mainly from the events of 11 September 2001. Research on rapid analytical methods that can allow analyses of large numbers of people who may become internally contaminated with radionuclides due to a RN accident is still limited. To contribute to this bioassay capacity for emergency response, the Radiation Protection Bureau of Health Canada has identified and evaluated two new portable SpectraMax plate readers (model 250 and Plus 384) and one brand of dry reagent strips for rapid measurement of creatinine in spot urine samples. Concentrations of creatinine in spot urine samples provide a means of adjusting or normalizing urine collections to 24 h, upon which accurate internal dose assessments due to the radionuclides can be made. Preliminary test results of the devices showed the two SpectraMax plate readers and the TECO dry creatinine reagent strips were portable, rapid and reliable for urinary creatinine measurements in spot samples, suggesting they can be used in rapid dose screening of people. PMID:21709503

  6. [Urine analysis in pregnancy].

    PubMed

    Schlembach, D

    2006-09-01

    Beside prevention routine antenatal care involves screening examinations for early diagnosis and therapy of pregnancy associated complications. Antenatal care guidelines recommend physical and especially vaginal examination, ultrasonographic evaluation, laboratory examinations, but also urine analysis. The commonly used urine analysis by dipstick can provide information on urinary tract infections, glucosuria and proteinuria. While the estimation of glucosuria has been found to be of no use for the detection of gestational diabetes and therefore is not recommended as a screening method for this disorder, urine analysis by dipstick or culture for bacteriuria or urinary tract infection followed by an antibiotic treatment is able to reduce maternal and neonatal complications. The most important role for urine analysis is the detection of proteinuria by routine dipstick examination and the quantification of proteinuria by 24 hour urin sampling in women with hypertensive disorders in pregnancy, especially in preeclampsia. PMID:17048173

  7. Combination of counter current salting-out homogenous liquid-liquid extraction and dispersive liquid-liquid microextraction as a novel microextraction of drugs in urine samples.

    PubMed

    Akramipour, Reza; Fattahi, Nazir; Pirsaheb, Meghdad; Gheini, Simin

    2016-02-15

    The counter current salting-out homogenous liquid-liquid extraction (CCSHLLE) joined with the dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) has been developed as a high preconcentration technique for the determination of different drugs in urine samples. Amphetamines were employed as model compounds to assess the extraction procedure and were determined by high performance liquid chromatography-ultraviolet detection (HPLC-UV). In this method, initially, NaCl as a separation reagent is filled into a small column and a mixture of urine and acetonitrile is passed through the column. By passing the mixture, NaCl is dissolved and the fine droplets of acetonitrile are formed due to salting-out effect. The produced droplets go up through the remained mixture and collect as a separated layer. Then, the collected acetonitrile is removed with a syringe and mixed with 30.0μL 1-undecanol (extraction solvent). In the second step, the 5.00mLK2CO3 solution (2% w/v) is rapidly injected into the above mixture placed in a test tube for further DLLME-SFO. Under the optimum conditions, calibration curves are linear in the range of 1-3000μgL(-1) and limit of detections (LODs) are in the range of 0.5-2μgL(-1). The extraction recoveries and enrichment factors ranged from 78 to 84% and 157 to 168, respectively. Repeatability (intra-day) and reproducibility (inter-day) of method based on seven replicate measurements of 100μgL(-1) of amphetamines were in the range of 3.5-4.5% and 4-5%, respectively. The method was successfully applied for the determination of amphetamines in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 90-108%. PMID:26828152

  8. Automated solid-phase extraction and liquid chromatography-electrospray ionization-mass spectrometry for the determination of flunitrazepam and its metabolites in human urine and plasma samples.

    PubMed

    Jourdil, N; Bessard, J; Vincent, F; Eysseric, H; Bessard, G

    2003-05-25

    A sensitive and specific method using reversed-phase liquid chromatography coupled with electrospray ionization-mass spectrometry (LC-ESI-MS) has been developed for the quantitative determination of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DMF) and 3-hydroxyflunitrazepam (3-OHF) in biological fluids. After the addition of deuterium labelled standards of F,7-AF and N-DMF, the drugs were isolated from urine or plasma by automated solid-phase extraction, then chromatographed in an isocratic elution mode with a salt-free eluent. The quantification was performed using selected ion monitoring of protonated molecular ions (M+H(+)). Experiments were carried out to improve the extraction recovery (81-100%) and the sensitivity (limit of detection 0.025 ng/ml for F and 7-AF, 0.040 ng/ml for N-DMF and 0.200 ng/ml for 3-OHF). The method was applied to the determination of F and metabolites in drug addicts including withdrawal urine samples and in one date-rape plasma and urine sample. PMID:12705961

  9. Microextraction by Packed Sorbent (MEPS) and Solid-Phase Microextraction (SPME) as Sample Preparation Procedures for the Metabolomic Profiling of Urine

    PubMed Central

    Silva, Catarina; Cavaco, Carina; Perestrelo, Rosa; Pereira, Jorge; Câmara, José S.

    2014-01-01

    For a long time, sample preparation was unrecognized as a critical issue in the analytical methodology, thus limiting the performance that could be achieved. However, the improvement of microextraction techniques, particularly microextraction by packed sorbent (MEPS) and solid-phase microextraction (SPME), completely modified this scenario by introducing unprecedented control over this process. Urine is a biological fluid that is very interesting for metabolomics studies, allowing human health and disease characterization in a minimally invasive form. In this manuscript, we will critically review the most relevant and promising works in this field, highlighting how the metabolomic profiling of urine can be an extremely valuable tool for the early diagnosis of highly prevalent diseases, such as cardiovascular, oncologic and neurodegenerative ones. PMID:24958388

  10. RNA amplification by nucleic acid sequence-based amplification with an internal standard enables reliable detection of Chlamydia trachomatis in cervical scrapings and urine samples.

    PubMed Central

    Morré, S A; Sillekens, P; Jacobs, M V; van Aarle, P; de Blok, S; van Gemen, B; Walboomers, J M; Meijer, C J; van den Brule, A J

    1996-01-01

    In the present study, the suitability of RNA amplification by nucleic acid sequence-based amplification (NASBA) for the detection of Chlamydia trachomatis infection was investigated. When comparing different primer sets for their sensitivities in NASBA, use of both the plasmid and omp1 targets resulted in a detection limit of 1 inclusion-forming unit (IFU), while the 16S rRNA appeared to be the most sensitive RNA target for amplification (10(-3) IFU). In contrast, for DNA amplification by PCR, the plasmid target was optimal (10(-2) IFU), which is 10 times less sensitive than rRNA NASBA. To exclude false negativity in NASBA detection because of inhibition of amplification and/or inefficient sample preparation, an internal standard was developed. The internal control was added prior to sample preparation. This 16S rRNA NASBA with an internal control was compared with a plasmid DNA PCR by using a group of C. trachomatis-negative (n = 41) and -positive (n = 37) cervical scrapings, as determined by enzyme immunoassay (EIA). In addition, urine samples from the EIA-positive women were tested (n = 17). Both NASBA and PCR assays were able to detect C. trachomatis in all EIA-positive cervical scrapings, the corresponding urine samples, and two samples from the EIA-negative group. The internal NASBA standard was found clearly in all EIA-negative samples. In conclusion, these results indicate that detection of C. trachomatis by RNA amplification by NASBA with an internal standard is a suitable and highly sensitive detection method, with potential use in the diagnosis of urogenital C. trachomatis infections with cervical scrapings as well as urine specimens. PMID:8940456

  11. The effect of dDAVP with saline loading on fluid balance during LBNP and standing after 24-hr head-down bedrest

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Fortney, S. M.; Ford, S. R.; Charles, J. B.; Ward, D. F.

    1994-01-01

    Shuttle astronauts currently drink approximately a quart of water with eight salt tablets before reentry to restore lost body fluid and thereby reduce the likelihood of cardiovascular instability and syncope during reentry and after landing. However, the saline loading countermeasure is not entirely effective in restoring orthostatic tolerance to preflight levels. We tested the hypothesis that the effectiveness of this countermeasure could be improved with the use of a vasopressin analog, 1-deamino-8-D-arginine vasopressin (dDAVP). The rationale for this approach is that reducing urine formation with exogenous vasopressin should increase the magnitude and duration of the vascular volume expansion produced by the saline load, and in so doing improve orthostatic tolerance during reentry and postflight.

  12. Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

    PubMed

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan

    2015-07-01

    A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. PMID:25953277

  13. [Preparation of molecularly imprinted polymers using dummy template and the applications in selective solid-phase extraction of seven bisphenols from human urine, bovine serum and beer samples].

    PubMed

    Yang, Jiajia; Li, Yun; Wang Jinchengt; Sun, Xiaoli; Chen, Jiping

    2015-05-01

    A molecularly imprinted polymer (MIP) for selective recognition of seven bisphenols (BPs) was prepared using dummy template phenolphthalein (PP) by bulk polymerization. The characterization results of scanning electron microscopy and nitrogen adsorption-desorption measurements showed that the prepared PP-MIP possessed narrow particle diameter distribution (40-60 µm), a specific surface area (S(BET)) of 359.77 m2/g and a total pore volume (Vt) of 0.730 cm3/g. The adsorption capacity for bisphenol A (BPA) of PP-MIP was evaluated by static adsorption experiment. And the Scatchard analysis revealed that the maximum specific adsorption capacity of PP-MIP was 4.661 µmol/g. Good class selectivity for BPA and its six structural analogues of bisphenol B (BPB) , bisphenol E (BPE), bisphenol AF (BPAF), bisphenol S (BPS), bisphenol AP (BPAP) and bisphenol Z (BPZ) was demonstrated by the chromatographic evaluation experiment. The prepared PP-MIP was successfully used as solid-phase extraction (SPE) sorbent for the separation and purification of the seven BPs in human urine, bovine serum and beer samples. Meanwhile, an accurate and sensitive MIP-SPE-HPLC method was established for the determination of the seven BPs in human urine, bovine serum and beer samples. The limits of detection (LODs) for the three samples were in the range of 1.2-2.0 µg/L. The results showed that good linearities were obtained in the range of 0.02-2 mg/L for the seven BPs and the correlation coefficients (r) were higher than 0.999 8. The recoveries of the BPs spiked in blank samples at two spiked levels (100 and 500 µg/L for each BP) were in the range of 90.1%-107.1% with the RSDs ≤ 8.1%. The proposed method is simple and reliable for the rapid detection of the seven BPs in human urine, bovine serum and beer samples. PMID:26387203

  14. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning

    PubMed Central

    SCHIER, J. G.; HUNT, D. R.; PERALA, A.; MCMARTIN, K. E.; BARTELS, M. J.; LEWIS, L. S.; MCGEEHIN, M. A.; FLANDERS, W. D.

    2015-01-01

    Context Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. Objective To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. Methods In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. Results The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6 – 75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14 – 118.4) and only five (23%) controls (median,

  15. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    PubMed

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. PMID:26772133

  16. The importance of a urine sample in persons intoxicated with flunitrazepam--legal issues in a forensic psychiatric case study of a serial murderer.

    PubMed

    Dåderman, Anna Maria; Strindlund, Hans; Wiklund, Nils; Fredriksen, Svend-Otto; Lidberg, Lars

    2003-10-14

    The sedative-hypnotic benzodiazepine flunitrazepam (FZ) is abused worldwide. The purpose of our study was to investigate violence and anterograde amnesia following intoxication with FZ, and how this was legally evaluated in forensic psychiatric investigations with the objective of drawing some conclusions about the importance of urine sample in a case of a suspected intoxication with FZ. The case was a 23-year-old male university student who, intoxicated with FZ (and possibly with other substances such as diazepam, amphetamines or cannabis), first stabbed an acquaintance and, 2 years later, two friends to death. The police investigation files, including video-typed interviews, the forensic psychiatric files, and also results from the forensic autopsy of the victims, were compared with the information obtained from the case. Only partial recovery from anterograde amnesia was shown during a period of several months. Some important new information is contained in this case report: a forensic analysis of blood sample instead of a urine sample, might lead to confusion during police investigation and forensic psychiatric assessment (FPA) of an FZ abuser, and in consequence wrong legal decisions. FZ, alone or combined with other substances, induces severe violence and is followed by anterograde amnesia. All cases of bizarre, unexpected aggression followed by anterograde amnesia should be assessed for abuse of FZ. A urine sample is needed in case of suspected FZ intoxication. The police need to be more aware of these issues, and they must recognise that they play a crucial role in an assessment procedure. Declaring FZ an illegal drug is strongly recommended. PMID:14550609

  17. Excretion of malondialdehyde, formaldehyde, acetaldehyde and acetone in the urine of rats following acute and chronic administration of ethanol.

    PubMed

    Moser, J; Bagchi, D; Akubue, P I; Stohs, S J

    1993-05-01

    Recent studies have shown that xenobiotics which induce oxidative stress result in an increased production and excretion of acetaldehyde (ACT), formaldehyde (FA), acetone (ACON) and malondialdehyde (MDA) in the urine of rats. We have therefore examined the effect of acute and chronic ethanol administration on the excretion of these four lipid metabolites in female Sprague-Dawley rats. Urine samples were collected over dry ice for 6 hr time periods. Aliquots of urine were derivatized with 2,4-dinitrophenylhydrazine HCl, and extracted with n-pentane. High pressure lipid chromatogrpahy (HPLC) was used to quantitate and the hydrazones of the four lipid metabolite products. Following a single, oral, acute dose of 5 g ethanol/kg, urinary excretion of ACT increased approximately 5.8-fold from 6 to 12 hr posttreatment, and decreased thereafter. FA excretion decreased by approximately 50% from 0 to 12 hr, returned to control values in the 18-24 hr urine samples, and was 1.3-fold greater than control values at 42-48 hr. ACON increased 3.1-fold over control values from 0 to 30 hr and remained elevated throughout the remaining 18 hr of the study. The excretion of MDA increased approximately 1.5-fold from 18 to 36 hr, then remained constant through the 48 hr time point. In a separate series of experiments, a chronic oral dose of 0.5 g ethanol/kg was administered to rats for 10 consecutive days and the urinary excretion of the lipid metabolites MDA, FA, ACT and ACON was examined for 11 days, beginning with the first day of ethanol administration.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8352840

  18. LC-MS/MS and volumetric absorptive microsampling for quantitative bioanalysis of cathinone analogues in dried urine, plasma and oral fluid samples.

    PubMed

    Mercolini, Laura; Protti, Michele; Catapano, Maria C; Rudge, James; Sberna, Angelo E

    2016-05-10

    In the last few years, several cathinone analogues have appeared on the illicit drug market and proposed as an alternative to already known stimulants in several recreational settings. The World Anti-Doping Agency classified the synthetic cathinones in the Prohibited List as specified stimulants, banned in sport competitions. We developed and validated an LC-MS/MS method for the analysis of methylone, ethylone, butylone, mephedrone, 4-methylethcathinone and 3,4-methylenedioxypyrovalerone in dried urine, plasma and oral fluid samples. Volumetric absorptive microsampling has been employed as a miniaturised sampling technique for collecting dried biological samples. Chromatographic analysis was carried out on a C18 reversed phase column with a mobile phase composed of formic acid in a water/acetonitrile mixture, by using a triple quadrupole mass analyzer. The main parameters of the volumetric absorptive microsampling procedure were investigated and the method was fully validated with satisfactory results in terms of linearity, precision, absolute recovery, matrix effects, selectivity and stability. The method was successfully applied to real samples collected from cathinones users. The biosampling strategy via volumetric absorptive microsampling for urine, plasma and oral fluid could provide reliable information, with a future perspective of implementation for forensic cases as well as for sport drug testing. PMID:26905673

  19. Electrochemical detection of toxic ractopamine and salbutamol in pig meat and human urine samples by using poly taurine/zirconia nanoparticles modified electrodes.

    PubMed

    Rajkumar, Muniyandi; Li, Ying-Sheng; Chen, Shen-Ming

    2013-10-01

    Detection of ractopamine and salbutamol has been developed by employing the facile synthesis of poly taurine/zirconia nanoparticles (ZrO2) modified film glassy carbon electrode. The poly taurine/ZrO2 nanoparticles were directly utilized for the detection of ractopamine and salbutamol using linear sweep voltammetry (LSV). The modified electrode successfully shows the oxidation peak for ractopamine adsorption at 0.65V and salbutamol at 0.71V, which is purely based on the detection of adsorption signals of ractopamine and salbutamol, at the electrode surface. Furthermore, the electrochemical measurements and surface morphology were studied using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) analysis. The modified electrode successfully detects the oxidation signals of ractopamine in the linear range of 1-28μM and salbutamol in the linear range of 5-220μM in laboratory samples. The proposed film also successfully detects the ractopamine signal (1-26μM) in pig meat samples and salbutamol signal (1-114μM) in human urine samples. It also exhibits two well-separated anodic oxidation peaks for uric acid and salbutamol in salbutamol-spiked human urine samples. PMID:23732800

  20. UHPLC-MS/MS method for the determination of bisphenol A and its chlorinated derivatives, bisphenol S, parabens, and benzophenones in human urine samples.

    PubMed

    Vela-Soria, F; Ballesteros, O; Zafra-Gómez, A; Ballesteros, L; Navalón, A

    2014-06-01

    In the present work, a new method based on a sample treatment by dispersive liquid-liquid microextraction (DLLME) for the extraction of six bisphenols (bisphenol A, bisphenol S, and monochloro-, dichloro-, trichloro-, and tetrachlorobisphenol A), four parabens (methyl-, ethyl-, propyl-, and butylparaben), and six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8, and 4-hydroxybenzophenone) in human urine samples, followed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis, is validated. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-(13)C6, benzophenone-d10, and bisphenol A-d16 were used as surrogates. Limits of quantification ranging from 0.1 to 0.6 ng mL(-1) and interday variabilities (evaluated as relative standard deviations) from 2.0 to 13.8% were obtained. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94 to 106%. A good linearity, for concentrations up to 300 ng mL(-1) for parabens and 40 ng mL(-1) for benzophenones and bisphenols, was also obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals. PMID:24710638

  1. Determination of parabens in urine samples by microextraction using packed sorbent and ultra-performance liquid chromatography coupled to tandem mass spectrometry.

    PubMed

    Cristina Jardim, Valeria; de Paula Melo, Lidervan; Soares Domingues, Diego; Costa Queiroz, Maria Eugênia

    2015-01-01

    A simple, sensitive, and selective method using ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination of parabens [methyl paraben (MeP), ethyl paraben (EtP), propyl paraben (PrP), butyl paraben (BuP), and benzyl paraben (BzP)] in human urine samples. After microextraction by packed sorbent (MEPS) using a C18 phase, the parabens were separated on a Kinetex C18 column (100 mm × 2.1 mm × 1.7 μm) within 4.6 min using isocratic elution. These compounds were detected on a triple quadrupole tandem mass spectrometer using the multiple reactions monitoring (MRM) mode via an electrospray ionization source operating in the negative ionization mode. Important factors that influence MEPS performance were evaluated, such as the sample pH, draw-eject sample volume, clean-up step, and desorption conditions. The proposed MEPS/UPLC-MS/MS method presented a linear range from 0.5 ng mL(-1) (limit of quantification - LOQ) to 50 ng mL(-1), and interassay precision with coefficients of variation lower than 15%, and relative standard error values of the accuracy ranged from -8.8% to 15%. The MEPS/UPLC-MS/MS method was applied successfully to determine parabens in urine samples from 30 postpartum volunteers, enabling assessment of human exposure to these compounds. PMID:25463195

  2. On the performance of multiway methods for simultaneous quantification of two fluoroquinolones in urine samples by fluorescence spectroscopy and second-order calibration strategies

    NASA Astrophysics Data System (ADS)

    Vosough, Maryam; Eshlaghi, Sara Noroozi; Zadmard, Reza

    2015-02-01

    In the present work, the analytical performance of three multi-way algorithms has been evaluated. The proposed analytical problem was the simultaneous determination of moxifloxacin and ciprofloxacin in human urine samples using fluorescence spectroscopy. Parallel factor analysis (PARAFAC), self-weighted alternating trilinear decomposition (SWATLD) and unfolded partial least squares combined with the residual bilinearization procedure (U-PLS/RBL) have been compared, regarding their ability to solve the proposed problem. In this study, "second-order advantage" was also exploited for the mentioned algorithms through different calibration strategies. The three-way data was obtained via fluorescence spectroscopy, so that excitation-emission matrices (EEM) of the samples were recorded as the analytical signals. The accuracy and precision of each individual algorithm for analyzing the drugs in urine samples were compared using root mean square error of prediction (RMSEP), recovery and elliptical joint confidence region (EJCR) plots. The results revealed that each of the three algorithms could be applied for determination of moxifloxacin and ciprofloxacin, despite different EEM subsets and calibration strategies. However, better analytical performances were observed through PARAFAC and U-PLS/RBL modeling for MOX and CIP, respectively. So, by coupling the multi-way decomposition algorithms with fluorescence spectroscopy, a main part of preliminary sample preparation steps can be eliminated and experimental procedure might be significantly simplified, while achieving desirable analytical performance.

  3. Feasibility of ultra-high performance liquid and gas chromatography coupled to mass spectrometry for accurate determination of primary and secondary phthalate metabolites in urine samples.

    PubMed

    Herrero, Laura; Calvarro, Sagrario; Fernández, Mario A; Quintanilla-López, Jesús Eduardo; González, María José; Gómara, Belén

    2015-01-01

    Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg μL(-1) and from 0.06 to 0.49 pg μL(-1) in GC-MS and UHPLC-MS(2), respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC-MS) and accuracy. But some advantages of the UHPLC-MS(2) method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC-MS(2) method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 μg L(-1)), followed by MiBP (23.3 μg L(-1)), 5cx-MEPP (22.5 μg L(-1)) and MBP (19.3μgL(-1)). MMP (6.99 μg L(-1)), 5oxo-MEHP (6.15 μg L(-1)), 5OH-MEHP (5.30 μg L(-1)) and MEHP (4.40 μg L(-1)) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 μg L(-1)). These data are within the same order of magnitude as those found in other similar populations. PMID:25467512

  4. Hydrophilic interaction chromatography combined with dispersive liquid-liquid microextraction as a preconcentration tool for the simultaneous determination of the panel of underivatized neurotransmitters in human urine samples.

    PubMed

    Konieczna, Lucyna; Roszkowska, Anna; Niedźwiecki, Maciej; Bączek, Tomasz

    2016-01-29

    A simple and sensitive method using dispersive liquid-liquid microextraction (DLLME) followed by liquid chromatography coupled to mass spectrometry (LC-MS) with a hydrophilic interaction chromatography (HILIC) column was developed for the simultaneous determination of 13 compounds of different polarities, comprising monoamine neurotransmitters (dopamine, norepinephrine, epinephrine and serotonin) along with their respective precursors and metabolites, in human urine samples. The microextraction procedure was based on the fast injection of a mixture of ethanol (disperser solvent) and dichloromethane (extraction solvent) into a human urine sample, forming a cloudy solution in the Eppendorf tube. After centrifugation, the sedimented phase was collected and subsequently analyzed by LC-HILIC-MS in about 12min without a derivatization step. The separation was performed on an XBridge Amide™ BEH column 3.0×100mm, 3.5mm and the mobile phase consisted of phase A: 10mM ammonium formate buffer in water pH 3.0 and phase B: 10 mM ammonium formate buffer in acetonitrile, under gradient program elution. Tyrosine, tryptophan, 5-hydroxytryptophan, dopamine, epinephrine, norepinephrine, serotonin, 3-methoxytyramine, 5-hydroxyindole-3-acetic acid, 3,4-dihydroxy-l-phenylalanine and norvaline (internal standard) were detected in the positive ionization mode. While vanillylmandelic acid, homovanillic acid, 3,4-dihydroxyphenylacetic acid and 3,4-dihydroxybenzylamine (internal standard) were detected in the negative ionization mode. Parameters influencing DLLME and LC-HILIC-MS were investigated. Under the optimum conditions, the proposed method exhibited a low detection limit (5-10ngmL(-1)), and good linearity with R between 0.9991 and 0.9998. The recoveries in human urine samples were 99.0%±3.6%. for the 13 studied biogenic amines with intra- and inter-day RSDs of 0.24-9.55% and 0.31-10.0%, respectively. The developed DLLME-LC-MS method could be successfully applied for the

  5. Urine sample preparation of tricyclic antidepressants by means of a supported liquid membrane technique for high-performance liquid chromatographic analysis.

    PubMed

    Trocewicz, J

    2004-03-01

    Supported liquid membrane (SLM) technique for sample work-up and enrichment was used for determination of tricyclic antidepressant drugs in urine by high-performance liquid chromatography (HPLC) with UV detection. The studied antidepressant drugs were amitriptyline, opipramol, noxiptyline and additionally diethazine was used as possible internal standard. Alkaline phosphoric buffer with urine sample, as the donor solution, was passed over the liquid membrane into which investigated substances were extracted. On the other side of the membrane, analyzed compounds were trapped due to creating non-extractable form in acidic acceptor solution. Enriched and cleaned up drugs were then injected into a HPLC system with ultraviolet detection to analyze of their concentration in acceptor solution. Optimum extraction efficiency was determined by changing acceptor and donor solutions pH, application of different flow rates of donor solution and by using different solvents in the membrane. Also, donor solution volume, extraction time and concentration of analytes were varied to check the linearity of extraction process. The highest extraction efficiency: 43% for opipramol, 56% for noxiptyline, 43% for amitriptyline and 42% for diethazine (R.S.D. values were <6% and n=3) was achieved when 0.05 M phosphate buffer pH 4.0 and 9.5 were used as donor and acceptor solutions, respectively, n-undecane with 5% tri-n-octylphosphine oxide (TOPO) was used as liquid membrane. Limit of quantification (LOQ) for tricyclic antidepressants after enrichment of 100ml of urine sample was about 1 ng/ml. PMID:14751789

  6. Variable-number tandem-repeat analysis of leptospiral DNA isolated from canine urine samples molecularly confirmed to contain pathogenic leptospires.

    PubMed

    Harkin, Kenneth R; Hays, Michael P

    2016-08-15

    OBJECTIVE To use variable-number tandem-repeat (VNTR) analysis to determine the infecting serovar and strain for leptospiral DNA isolated from canine urine samples confirmed through PCR testing to contain pathogenic leptospires and to evaluate the sensitivity and specificity of microscopic agglutination testing (MAT) for identifying the infecting serogroup. DESIGN Diagnostic survey and test evaluation. SAMPLE Leptospiral DNA isolated from urine samples from 98 dogs confirmed through PCR testing to have pathogenic leptospires in their urine. PROCEDURES VNTR analysis of DNA isolates was performed to identify the infecting leptospiral serovar and strain by use of primer pairs for the loci 4, 7, 10, and Lb5. Eighteen pathogenic and 2 saprophytic leptospiral serovars were used as reference strains for VNTR analysis. Results of MAT were compared with those of the PCR assay and VNTR analysis to determine the sensitivity and specificity of MAT for diagnosing leptospirosis and identifying the infecting serovar at various reciprocal titers. RESULTS VNTR analysis identified Leptospira kirschneri serovar Grippotyphosa strain DF as the most common infecting serovar in dogs (78/98 [80%]). Thirteen unique VNTR patterns could not be identified by comparison with the Leptospira reference strains used. The MAT had a maximum sensitivity of 41% and a specificity of 100% for identifying Grippotyphosa as the infecting serogroup. CONCLUSIONS AND CLINICAL RELEVANCE Findings confirmed the importance of Leptospira serovar Grippotyphosa among dogs in the United States. Serologic testing had poor sensitivity for identifying the infecting serogroup, and conclusions about emerging serogroups should be cautiously interpreted when serologic data are reported. PMID:27479284

  7. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    NASA Technical Reports Server (NTRS)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  8. Calcium - urine

    MedlinePlus

    ... into the urine, which causes calcium kidney stones Sarcoidosis Taking too much calcium Too much production of ... Milk-alkali syndrome Proximal renal tubular acidosis Rickets Sarcoidosis Vitamin D Update Date 5/3/2015 Updated ...

  9. Frequent Urination

    MedlinePlus

    ... leader Partner Spotlight Become a partner World Prematurity Day Your support helps babies We are determined to ... very strong. After birth For the first few days after delivery, you may urinate even more often ...

  10. Urination Pain

    MedlinePlus

    ... Are Reading Upsetting News Reports? What to Say Vaccines: Which Ones & When? Smart School Lunches Emmy-Nominated Video "Cerebral Palsy: Shannon's Story" 5 Things to Know About Zika & Pregnancy First Aid: Urination ...

  11. Calcium - urine

    MedlinePlus

    ... best treatment for the most common type of kidney stone , which is made of calcium. This type of ... the kidneys into the urine, which causes calcium kidney stones Sarcoidosis Taking too much calcium Too much production ...

  12. Bilirubin - urine

    MedlinePlus

    ... or gallbladder Considerations Bilirubin can break down in light. That is why babies with jaundice are sometimes placed under blue fluorescent lamps. Alternative Names Conjugated bilirubin - urine; Direct bilirubin - ...

  13. Urine Preservative

    NASA Technical Reports Server (NTRS)

    Smith, Scott M. (Inventor); Nillen, Jeannie (Inventor)

    2001-01-01

    Disclosed is CPG, a combination of a chlorhexidine salt (such as chlorhexidine digluconate, chlorhexidine diacetate, or chlorhexidine dichloride) and n-propyl gallate that can be used at ambient temperatures as a urine preservative.

  14. Ketones urine test

    MedlinePlus

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  15. Urine 24-hour volume

    MedlinePlus

    ... in a day, such as: Creatinine Sodium Potassium Nitrogen Protein This test may also be done if ... disease Potassium urine test Sodium urine test Urea nitrogen urine test Urination - excessive amount Urine output - decreased ...

  16. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    PubMed

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-01

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. PMID:26971030

  17. Generation of integration free induced pluripotent stem cells from fibrodysplasia ossificans progressiva (FOP) patients from urine samples.

    PubMed

    Hildebrand, Laura; Rossbach, Bella; Kühnen, Peter; Gossen, Manfred; Kurtz, Andreas; Reinke, Petra; Seemann, Petra; Stachelscheid, Harald

    2016-01-01

    Fibrodysplasia ossificans progressiva (FOP) is an extremely rare, autosomal dominant transmitted genetic disease. Patients experience progressive bone formation replacing tendons, ligaments, muscle and soft tissue. Cause of FOP are gain-of-function mutations in the Bone Morphogenetic Protein (BMP) receptor Activin A receptor type 1 (ACVR1) (Kaplan et al., 2008). The most common mutation is R206H, which leads to the substitution of codon 206 from arginine to histidine (Shore et al., 2006). Here, we describe the derivation and characterization of two hiPSC lines from two FOP patients, both carrying the mutation R206H. Cells were isolated from urine and reprogrammed using integration free Sendai virus vectors under defined conditions. PMID:27345784

  18. Metabolomic Profiling of Urine Samples from Mice Exposed to Protons Reveals Radiation Quality and Dose Specific Differences

    PubMed Central

    Laiakis, Evagelia C.; Trani, Daniela; Moon, Bo-Hyun; Strawn, Steven J.; Fornace, Albert J.

    2015-01-01

    As space travel is expanding to include private tourism and travel beyond low-Earth orbit, so is the risk of exposure to space radiation. Galactic cosmic rays and solar particle events have the potential to expose space travelers to significant doses of radiation that can lead to increased cancer risk and other adverse health consequences. Metabolomics has the potential to assess an individual’s risk by exploring the metabolic perturbations in a biofluid or tissue. In this study, C57BL/6 mice were exposed to 0.5 and 2 Gy of 1 GeV/nucleon of protons and the levels of metabolites were evaluated in urine at 4 h after radiation exposure through liquid chromatography coupled to time-of-flight mass spectrometry. Significant differences were identified in metabolites that map to the tricarboxylic acid (TCA) cycle and fatty acid metabolism, suggesting that energy metabolism is severely impacted after exposure to protons. Additionally, various pathways of amino acid metabolism (tryptophan, tyrosine, arginine and proline and phenylalanine) were affected with potential implications for DNA damage repair and cognitive impairment. Finally, presence of products of purine and pyrimidine metabolism points to direct DNA damage or increased apoptosis. Comparison of these metabolomic data to previously published data from our laboratory with gamma radiation strongly suggests a more pronounced effect on metabolism with protons. This is the first metabolomics study with space radiation in an easily accessible biofluid such as urine that further investigates and exemplifies the biological differences at early time points after exposure to different radiation qualities. PMID:25768838

  19. Metabolomic profiling of urine samples from mice exposed to protons reveals radiation quality and dose specific differences.

    PubMed

    Laiakis, Evagelia C; Trani, Daniela; Moon, Bo-Hyun; Strawn, Steven J; Fornace, Albert J

    2015-04-01

    As space travel is expanding to include private tourism and travel beyond low-Earth orbit, so is the risk of exposure to space radiation. Galactic cosmic rays and solar particle events have the potential to expose space travelers to significant doses of radiation that can lead to increased cancer risk and other adverse health consequences. Metabolomics has the potential to assess an individual's risk by exploring the metabolic perturbations in a biofluid or tissue. In this study, C57BL/6 mice were exposed to 0.5 and 2 Gy of 1 GeV/nucleon of protons and the levels of metabolites were evaluated in urine at 4 h after radiation exposure through liquid chromatography coupled to time-of-flight mass spectrometry. Significant differences were identified in metabolites that map to the tricarboxylic acid (TCA) cycle and fatty acid metabolism, suggesting that energy metabolism is severely impacted after exposure to protons. Additionally, various pathways of amino acid metabolism (tryptophan, tyrosine, arginine and proline and phenylalanine) were affected with potential implications for DNA damage repair and cognitive impairment. Finally, presence of products of purine and pyrimidine metabolism points to direct DNA damage or increased apoptosis. Comparison of these metabolomic data to previously published data from our laboratory with gamma radiation strongly suggests a more pronounced effect on metabolism with protons. This is the first metabolomics study with space radiation in an easily accessible biofluid such as urine that further investigates and exemplifies the biological differences at early time points after exposure to different radiation qualities. PMID:25768838

  20. Evaluating 3D printing to solve the sample-to-device interface for LRS and POC diagnostics: example of an interlock meter-mix device for metering and lysing clinical urine samples.

    PubMed

    Jue, Erik; Schoepp, Nathan G; Witters, Daan; Ismagilov, Rustem F

    2016-05-21

    This paper evaluates the potential of 3D printing, a semi-automated additive prototyping technology, as a means to design and prototype a sample-to-device interface, amenable to diagnostics in limited-resource settings, where speed, accuracy and user-friendly design are critical components. As a test case, we built and validated an interlock meter-mix device for accurately metering and lysing human urine samples for use in downstream nucleic acid amplification. Two plungers and a multivalve generated and controlled fluid flow through the device and demonstrate the utility of 3D printing to create leak-free seals. Device operation consists of three simple steps that must be performed sequentially, eliminating manual pipetting and vortexing to provide rapid (5 to 10 s) and accurate metering and mixing. Bretherton's prediction was applied, using the bond number to guide a design that prevents potentially biohazardous samples from leaking from the device. We employed multi-material 3D printing technology, which allows composites with rigid and elastomeric properties to be printed as a single part. To validate the meter-mix device with a clinically relevant sample, we used urine spiked with inactivated Chlamydia trachomatis and Neisseria gonorrhoeae. A downstream nucleic acid amplification by quantitative PCR (qPCR) confirmed there was no statistically significant difference between samples metered and mixed using the standard protocol and those prepared with the meter-mix device, showing the 3D-printed device could accurately meter, mix and dispense a human urine sample without loss of nucleic acids. Although there are some limitations to 3D printing capabilities (e.g. dimension limitations related to support material used in the printing process), the advantages of customizability, modularity and rapid prototyping illustrate the utility of 3D printing for developing sample-to-device interfaces for diagnostics. PMID:27122199

  1. Ionic liquid-based dynamic liquid-phase microextraction: application to the determination of anti-inflammatory drugs in urine samples.

    PubMed

    Cruz-Vera, Marta; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-08-15

    Dynamic liquid-phase microextraction (dLPME) using an ionic liquid as acceptor phase is proposed for the determination of six non-steroidal anti-inflammatory drugs (NSAIDs) in human urine samples for the first time. The extraction is carried out in a simple and automatic flow configuration. The chemical affinity between the extractant (1-butyl-3-methylimidazolium hexafluorophosphate) and the analytes permits a selective isolation of the drugs from the sample matrix allowing also their preconcentration. The whole analytical method has been optimized taking into account all the chemical, physical and hydrodynamic variables. The proposed method is a valuable alternative for the analysis of these drugs in urine within the concentration range 0.1-10 microg mL(-1), allowing their determination at therapeutic and toxic levels. Limits of detection were in the range from 38 ng mL(-1) (indomethacin) to 70 ng mL(-1) (naproxen). The repeatability of the proposed method expressed as RSD (n=5) varied between 2.1% (flurbiprofen) and 3.8% (tolmetin). PMID:18632109

  2. N-acetyl-4-aminophenol (paracetamol) in urine samples of 6-11-year-old Danish school children and their mothers.

    PubMed

    Nielsen, Jeanette K S; Modick, Hendrik; Mørck, Thit A; Jensen, Janne F; Nielsen, Flemming; Koch, Holger M; Knudsen, Lisbeth E

    2015-01-01

    Recent studies indicate an association between the use of paracetamol during pregnancy and reproductive disorders in male offspring. Furthermore, N-acetyl-4-aminophenol (NAAP, paracetamol) has been shown to be ubiquitously excreted in urine samples of the general population. To investigate the internal body burden of the Danish population to NAAP for the first time, 288 morning urine samples from 6- to 11-year-old Danish school children and their mothers were analyzed for NAAP. NAAP was measurable in all mothers and all of the children except for one child. Results showed that there is a ubiquitous body burden of NAAP in Danish mothers and children even when paracetamol analgesics have not been used recently. Hence, several unknown sources of NAAP/paracetamol exposure have to exist. We found an association in NAAP excretion between the mothers and their children which could indicate common lifestyle related exposure (e.g. via food or indoor air sources). However, we did not detect any association between lifestyle data from questionnaires and levels of NAAP excretion in this study. The knowledge about possible sources of exposure leading to this omnipresent paracetamol excretion is limited and further investigation is wanted. PMID:25127489

  3. Determination of ketamine and its major metabolite, norketamine, in urine and plasma samples using microextraction by packed sorbent and gas chromatography-tandem mass spectrometry.

    PubMed

    Moreno, Ivo; Barroso, Mário; Martinho, Ana; Cruz, Angelines; Gallardo, Eugenia

    2015-11-01

    Ketamine is a club drug widely abused for its hallucinogenic effects, being also used as a "date-rape" drug in recent years. We have developed an analytical method using gas chromatography-tandem mass spectrometry (GC-MS/MS) for the identification and quantification of ketamine and its major metabolite in urine and plasma. No derivatization step is needed to accomplish analysis. The compounds were extracted from 0.25mL of sample using microextraction by packed sorbent on mixed mode (M1) cartridges. Calibration curves were linear in the range of 10-250ng/mL for urine and 10-500ng/mL for plasma, with determination coefficients higher than 0.99. The limit of detection (LOD) was 5ng/mL for both compounds in both specimens. Recoveries ranged from 63 to 101%, while precision and accuracy were below 14% and 15%, respectively. These low limits of detection and the quite high recoveries obtained, in very low sample amounts, allow detecting small quantities of the compounds, making this procedure suitable for those laboratories performing routine analysis in the field of forensic toxicology. Compared with existing methods, the herein described procedure is fast, since no derivatization step is required, and cost effective for the quantification of ketamine and norketamine in biological specimens by gas chromatography. PMID:26447937

  4. In-syringe reversed dispersive liquid-liquid microextraction for the evaluation of three important bioactive compounds of basil, tarragon and fennel in human plasma and urine samples.

    PubMed

    Barfi, Azadeh; Nazem, Habibollah; Saeidi, Iman; Peyrovi, Moazameh; Afsharzadeh, Maryam; Barfi, Behruz; Salavati, Hossein

    2016-03-20

    In the present study, an efficient and environmental friendly method (called in-syringe reversed dispersive liquid-liquid microextraction (IS-R-DLLME)) was developed to extract three important components (i.e. para-anisaldehyde, trans-anethole and its isomer estragole) simultaneously in different plant extracts (basil, fennel and tarragon), human plasma and urine samples prior their determination using high-performance liquid chromatography. The importance of choosing these plant extracts as samples is emanating from the dual roles of their bioactive compounds (trans-anethole and estragole), which can alter positively or negatively different cellular processes, and necessity to a simple and efficient method for extraction and sensitive determination of these compounds in the mentioned samples. Under the optimum conditions (including extraction solvent: 120 μL of n-octanol; dispersive solvent: 600 μL of acetone; collecting solvent: 1000 μL of acetone, sample pH 3; with no salt), limits of detection (LODs), linear dynamic ranges (LDRs) and recoveries (R) were 79-81 ng mL(-1), 0.26-6.9 μg mL(-1) and 94.1-99.9%, respectively. The obtained results showed that the IS-R-DLLME was a simple, fast and sensitive method with low level consumption of extraction solvent which provides high recovery under the optimum conditions. The present method was applied to investigate the absorption amounts of the mentioned analytes through the determination of the analytes before (in the plant extracts) and after (in the human plasma and urine samples) the consumption which can determine the toxicity levels of the analytes (on the basis of their dosages) in the extracts. PMID:26802527

  5. Pink urine.

    PubMed

    Verhoeven, E; Capron, A; Hantson, P

    2014-11-01

    A 55-year-old man was admitted after a suspected hypnotic overdose of valerian extracts. In addition to altered consciousness, the first clinical symptoms included not only diffuse rash on the face, trunk, and limbs, but also an inspiratory dyspnea with a marked hypoxemia. A major laryngeal edema was noted during orotracheal intubation. After correction of hypoxemia, the patient became agitated and propofol was administered by continuous infusion. In addition, the patient passed pink urine staining the urine collection bag. The presence of an unidentified toxic substance was suspected. PMID:25233954

  6. Vortex-assisted liquid-liquid extraction combined with field-amplified sample injection and sweeping micellar electrokinetic chromatography for improved determination of β-blockers in human urine.

    PubMed

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2016-03-01

    A new micellar electrokinetic chromatography (MEKC) method was developed and validated for the analysis of carvedilol and propranolol in human urine samples. In this study, vortex-assisted liquid-liquid extraction (VALLE) coupled with field-amplified sample injection and sweeping was employed for biological sample clean-up and sensitivity enhancement in MEKC. After VALLE, the urine samples were analyzed by MEKC. Tris-phosphate buffer (60mmolL(-1), pH 2.0) containing 40% (v/v) methanol was first filled into an uncoated fused-silica capillary (56cm, 50µm i.d.). The pretreated urine sample was loaded by electrokinetic injection (10kV, 250s). The stacking and separation were performed using Tris-phosphate buffer (30mmolL(-1), pH 3.0) containing 30% (v/v) methanol and 50mmolL(-1) sodium dodecyl sulfate (SDS) at -25kV. Detection was carried out at 195 and 214nm for carvedilol and propranolol, respectively. The suggested method is linear (r(2)≥0.997) over a dynamic range of 0.005-1µgmL(-1) in urine. The intra- and inter-day relative standard deviation and relative error values of the method were below 20%, which shows good precision and accuracy. Finally, this method was successfully applied to the analysis of real urine samples. PMID:26717845

  7. Separation and quantitative determination of cinacalcet metabolites in urine sample using RP-HPLC after derivation with a fluorescent labeling reagent.

    PubMed

    Farnoudian-Habibi, Amir; Jaymand, Mehdi

    2016-08-01

    In this investigation, a novel strategy for separation and quantitative determination of four metabolites of cinacalcet (M2a-Glu, M2b-Glu, M7-Gly, and M8-Gly) in human urine is suggested. The analytical assay is based on a pre-column derivation procedure of cinacalcet metabolites with 1-pyrenyldiazomethane (PDAM) as a fluorescent labeling reagent, and subsequently separation and quantitative determination with reverse-phase high-performance liquid chromatography (RP-HPLC) coupled with a fluorescence detector. Metabolites were separated on a Microsorb-MV 100-5 C18 chromatography column (250×4.6mm, 5μm) using acetate buffer (pH 3.5):methanol (30:70 v/v) as mobile phase at a flow rate of 1.0mLmin(-1). The method was fully validated in terms of linearity (r(2)>0.996; 1-10ngmL(-1)), precision (both intra-day and inter-day; RSD<6.2%), accuracy (92-110%), specificity, robustness (0.15%urine samples. PMID:27304782

  8. Analysis of monofluoroacetic acid in urine by liquid chromatography-triple quadrupole mass spectrometry and preparation of the positive sample by the bioconversion from monofluoroacetamide to monofluoroacetic acid in vitro.

    PubMed

    Xu, Xiao-Min; Cai, Zeng-Xuan; Zhang, Jing-Shun; Ren, Yiping; Han, Jian-Long

    2016-08-01

    Whether as a rodenticide or as a natural product, monofluoroacetic acid (FAcOH) may cause poisoning to humans or animals for its high acute toxicity. Urine is one of the most typical specimens for forensic diagnosis when poisoning case about FAcOH happens. The positive sample containing FAcOH plays a key role for the development of an accurate and reliable analytical method. The bioconversion from monofluoroacetamide (FAcNH2) to FAcOH in urine in vitro was studied for the preparation of positive urine sample containing FAcOH without standard spiking or animal experiment. The average bioconversion rates were 0%, 18.6% and 41.3% when incubated the FAcNH2 spiked urine in vitro for 21days at -20°C, room temperature (RT) and 37°C, respectively. Afterwards, a fast and sensitive analytical method was developed for determination of FAcOH in urine. Samples were diluted with water containing formic acid and cleaned with polymeric anion exchange (PAX) cartridge. The acid eluate was neutralized with ammonium hydroxide and directly measured by hydrophilic interaction liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) using basic mobile phase condition. The limit of detection and limit of quantification of FAcOH in urine were 2 and 5ngmL(-1), respectively. The linear range was 5-1000ngmL(-1) with a correlation coefficient of r=0.9993 in urine calibrated with internal standard. The recoveries at four spiking levels (5, 10, 50 and 500ngmL(-1) in urine) were 87.2%-107% with relative standard deviations ranged between 4.3%-8.8%. PMID:27284971

  9. Highly class-selective solid-phase extraction of bisphenols in milk, sediment and human urine samples using well-designed dummy molecularly imprinted polymers.

    PubMed

    Sun, Xiaoli; Wang, Jincheng; Li, Yun; Jin, Jing; Yang, Jiajia; Li, Fang; Shah, Syed Mazhar; Chen, Jiping

    2014-09-19

    Dummy molecularly imprinted polymers (DMIPs) towards bisphenols (BPs) were prepared employing 1,1,1-tris(4-hydroxyphenyl)ethane (THPE) and phenolphthalein (PP) as dummy templates. The selectivity of the resulting DMIPs was evaluated by high-performance liquid chromatography (HPLC). Both PP-DMIP and THPE-DMIP showed excellent class selectivity towards bisphenols. THPE-DMIP prepared using the template molecule with three hydroxyphenyl functionalities achieved higher imprinting factors (IF) for the bisphenols over a range of 7.9-19.8. An efficient approach based on dummy molecularly imprinted solid phase extraction (DMISPE) coupled with HPLC-DAD was developed for selective extraction of eight bisphenols in sediment, milk and human urine samples using THPE-DMIP as sorbents. The method showed good recoveries (82-102%) and precision (RSD 0.2-4%, n=3) for these samples spiked at two concentration levels (25 and 250ngg(-1) or ngmL(-1)). The detection limits ranged between 0.6 and 1.1ngg(-1) or ngmL(-1). Efficient removal of sample matrix and interferences was also achieved for these samples after DMISPE process. The results demonstrated great potential of the optimized methods for sample preparation in the routine analysis of trace BPs in complex samples. PMID:25130092

  10. Urine culture - catheterized specimen

    MedlinePlus

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  11. Organophosphate Insecticide Metabolites in Prenatal and Childhood Urine Samples and Intelligence Scores at 6 Years of Age: Results from the Mother–Child PELAGIE Cohort (France)

    PubMed Central

    Cartier, Chloé; Warembourg, Charline; Le Maner-Idrissi, Gaïd; Lacroix, Agnès; Rouget, Florence; Monfort, Christine; Limon, Gwendolina; Durand, Gaël; Saint-Amour, Dave; Cordier, Sylvaine; Chevrier, Cécile

    2015-01-01

    Background: Several studies suggest that exposure to organophosphate insecticides (OP) during pregnancy impairs neurodevelopment in children. Objectives: We evaluated associations between biomarkers of prenatal and postnatal OP exposure and cognitive function of 6-year-olds in a French longitudinal birth cohort. Methods: In 2002–2006, the PELAGIE mother–child cohort enrolled pregnant women from Brittany. For a random subcohort, we measured nonspecific dialkylphosphate metabolites (DAP) of OP in one maternal urine sample, collected before 19 weeks’ gestation, and in one urine sample collected from their 6-year-old children. Six subtests of the Wechsler Intelligence Scale for Children, 4th edition (WISC-IV) were administered when the children were 6 years of age to evaluate cognitive function (n = 231). Linear regression models controlling for factors including maternal intelligence and the Home Observation for Measurement of the Environment score were used. Results: WISC-IV scores were not significantly associated with prenatal or childhood total DAP metabolites. WISC verbal comprehension score was significantly higher in association with the highest maternal urinary concentrations of diethylphosphate (DE) metabolites (5.5; 95% CI: 0.8, 10.3 for > 13.2 nmol/L vs. < LOQ), whereas WISC working memory score was significantly lower in association with the highest urinary concentrations of DE metabolites at age 6 years (–3.6; 95% CI: –7.8, –0.6 for > 11.1 nmol/L vs. < LOD). Conclusion: We found no evidence that prenatal OP exposure adversely affected cognitive function in 6-year-olds, perhaps because of the population’s socioeconomic status, which was higher than in previous studies, though other causal and noncausal explanations are also possible. The negative association between WISC score and concurrent DE urinary concentrations requires replication by longitudinal studies investigating childhood OP exposure. Citation: Cartier C, Warembourg C, Le Maner

  12. Determination of the pyrethroid insecticide metabolite 3-PBA in plasma and urine samples from farmer and consumer groups in northern Thailand

    PubMed Central

    THIPHOM, SARUNYA; PRAPAMONTOL, TIPPAWAN; CHANTARA, SOMPORN; MANGKLABRUKS, AMPICA; SUPHAVILAI, CHAISUREE; AHN, KI CHANG; GEE, SHIRLEY J.; HAMMOCK, BRUCE D.

    2014-01-01

    In this study, the enzyme-linked immunosorbent assays (ELISA) were modified to detect 3-PBA in plasma (including the adducted form) and urine among a large group of consumers and farmers in an agricultural area. The samples were collected on the same day in the morning from 100 consumers (50 females, 50 males) and 100 farmers (50 females, 50 males) in the Fang district, Chiang Mai province, northern Thailand. The ELISA was very sensitive having an IC50 value of 26.7 and 15.3 ng/mL, a limit of quantitation of 5 and 2.5 ng/mL and a limit of detection of 1.08 and 1.94 ng/mL for plasma and urine, respectively. These methods had low (< 5%) intra- and inter-assay coefficients of variation. The extraction technique satisfactorily eliminated the matrix effect from samples before ELISA analysis, yielding good recoveries (85.9–99.4% and 87.3–98.0%, respectively). For the volunteer study, the detection rate for plasma 3-PBA was 24% in consumers and 42% in farmers, but the median and range values were similar (median 5.87 ng/mL, range 5.16–8.44 ng/mL in consumers and 6.27 ng/mL, range 4.29–9.57 ng/mL in farmers). The rate of detection in the urine was similar (76% and 69%, in consumers and in farmers), yet the median concentration was significantly higher in farmers (8.86 μg/g creatinine in consumers vs 16.1 μg/g creatinine in farmers) and the range also much wider in farmers (1.62–80.5 μg/g creatinine in consumers and 0.80–256.2 μg/g creatinine in farmers). There was no correlation between plasma 3-PBA and urinary 3-PBA concentrations in the study presumably because plasma 3-PBA is a measure of cumulative exposures while urinary 3-PBA reflects acute exposures. In addition, metabolism and excretion of pyrethroids varies by individual. Nevertheless, this study demonstrated that these volunteers were exposed to pyrethroids. To our knowledge, this is the first report that compared plasma 3-PBA and urinary 3-PBA in a large group of volunteers. The ELISA method

  13. Quantification of 1-hydroxypyrene in undiluted human urine samples using magnetic solid-phase extraction coupled with internal extractive electrospray ionization mass spectrometry.

    PubMed

    Zhang, Hua; Lu, Haiyan; Huang, Haichun; Liu, Jianchuan; Fang, Xiaowei; Yuan, Bi-Feng; Feng, Yu-Qi; Chen, Huanwen

    2016-07-01

    Polycyclic aromatic hydrocarbons (PAHs) are a group of ubiquitous environmental contaminants raising worldwide concerns due to their carcinogenic effects. In this study, 1-hydroxypyrene (1-OHP, the most widely used biomarker of internal dose of PAHs exposure) in undiluted human urine samples (10 mL) was selectively enriched by polypyrrole-coated Fe3O4 magnetite nanocomposites (termed as Fe3O4@Ppy, 1 mg) and then directly eluted by the electrospraying solvent (acetone/benzene/acetic acid (v/v/v, 90/10/1); 100 uL) biased with -3.5 kV to produce the deprotonated 1-OHP anions for mass spectrometric analysis. The method established here significantly improved the current performance for detection of urinary 1-OHP, providing the speed for a single sample analysis within 4 min, the limits of detection (LOD) of 0.0001 μg L(-1), the linear response range of 0.001-5.000 μg L(-1) (R(2) = 0.9994), recovery rates of 90.6-96.1%, and relative standard deviation (RSD, n = 6) values between 2.9% and 8.0%. Human samples including raw human urine collected from 10 healthy volunteers (5 smokers and 5 nonsmokers) and 7 lung cancer patients have been successfully analyzed, showing that magnetic solid-phase extraction (MSPE) coupled with internal extractive electrospray ionization mass spectrometry (iEESI-MS) is an alternative strategy for high throughput quantitative detection of urinary 1-OHP for health risk assessment of PAHs exposure. PMID:27216395

  14. Magnetic solid-phase extraction using poly(para-phenylenediamine) modified with magnetic nanoparticles as adsorbent for analysis of monocyclic aromatic amines in water and urine samples.

    PubMed

    Amiri, Amirhassan; Baghayeri, Mehdi; Nori, Somayeh

    2015-10-01

    In the present work, a simple and effective method based on magnetic separation has been developed for the extraction of monocyclic aromatic amines in water and urine samples using poly(para-phenylenediamine) modified with Fe3O4 nanoparticles (PpPD/Fe3O4) as an adsorbent. The chemical structures of the sorbent were characterized by field emission scanning electron microscopy (FESEM) and Fourier transform infrared spectrophotometer (FT-IR). Various parameters affecting on the extraction efficiency of desired analytes, such as pH of solution, desorption conditions, extraction time, salt effect and amount of adsorbent have been investigated and optimized. The obtained optimal conditions were: sample pH, 6; amount of sorbent, 20mg; sorption time, 2min; elution solvent and its volume, dichloromethane and chloroform (3:1 v/v), 250μL; elution time, 30s and without addition of NaCl. Under the optimum conditions, detection limits in the range of 0.007-0.01ngmL(-1) were obtained by gas chromatography-flame ionization detector (GC-FID). The calibration curves were linear in the range 0.05-100ngmL(-1) with a correlation coefficient better than 0.9953. In addition, a satisfactory reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 5.9 and 7.3%, respectively. The proposed procedure has been successfully applied to the determination of target analytes in water and urine samples. The results demonstrated that the developed method is simple, inexpensive, accurate and remarkably free from interference effects. PMID:26341590

  15. Liver, lung and kidney homogenates used as an activation system in mutagenicity studies of airborne particles and of expectorate and urine samples from exposed workers in a coke plant.

    PubMed

    Krøkje, A; Schmid, R; Zahlsen, K

    1991-01-01

    A comparison was made between lung and kidney homogenates on the one hand and liver S9 from rats on the other hand in order to compare their ability to activate promutagens. The Salmonella reversion assay was used on extracts of airborne particles from the top of coke oven batteries, and of expectorate and urine samples from exposed workers in the same coke plant. The contents of benzo[a]anthracene and benzo[a]pyrene in the different test solutions were measured by high-resolution gas chromatography/mass spectrometry. Both mutagens were detected in the filter extract and in the expectorates from the exposed workers but not in the expectorates from the control groups or in the urine samples. The liver S9 gave significantly higher mutagenicity than lung and kidney activation with both filter samples and expectorate and urine samples. PMID:1988823

  16. Stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet/inductively coupled plasma mass spectrometry for analysis of thyroxine in urine samples.

    PubMed

    Fan, Wenying; Mao, Xiangju; He, Man; Chen, Beibei; Hu, Bin

    2013-11-29

    tIn this work, polyethyleneglycol (PEG)/hydroxyl polydimethylsiloxane (OH-PDMS)/γ -mercaptopropyltrimethoxysilane (γ -MPTS) coated stir bar was prepared by sol–gel process and its extraction performance for the extraction of amphoteric thyroxines (3,3',5,5'-tetraiodothyronin, T(4); 3,3',5-triiodothyronine, T(3); reversed-3,3',5-triiodothyronine, rT(3)) and their metabolite (3,5-diiodothyronine,T2) was studied. The preparation reproducibility of PEG/OH-PDMS/γ -MPTS coated stir bar was investigated, and the relative standard deviations (RSDs) in the same batch and among different batches were 3.3–14.3% (n = 5) and 7.7–16.6% (n = 3), respectively. The prepared PEG/OH-PDMS/γ -MPTS coated stir bar could be reused for more than 20 times. Based on this fact, a novel method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV)and HPLC-inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of target thyroxinesin human urine samples was developed. The influencing factors of SBSE, such as sample pH, extraction time, stirring rate, salt effect, desorption solution and desorption time, were studied in detail, and the analytical performance of the proposed method was evaluated under the optimized conditions. The enrichment factors (EFs) of the developed method for four target thyroxines were in the range of 14.9–70.4(theoretical enrichment factor was 100). The RSDs were ranging from 4.0% to 13.8% for SBSE-HPLC-UV (c = 25 μg/L, n = 6) and from 3.7% to 6.1% for SBSE-HPLC-ICP-MS (c = 0.5 μg/L, n = 5). The linear range obtained by SBSE-HPLC-UV was 2–500 μg/L for T(2)and 5–500 μg/L for rT3, T(3)and T(4), with correlation coefficients (r) ranging from 0.9957 to 0.9998, respectively, while the linear range obtained by SBSE-HPLC-ICP-MS was 0.05–500 μg/L for T(2) and rT(3), 0.10–200 μg/L for T(3) and 0.05–200 μg/L for T(4)with r ranging from 0.9979 to 0.9998, respectively. The

  17. Direct online HPLC-CV-AFS method for traces of methylmercury without derivatisation: a matrix-independent method for urine, sediment and biological tissue samples.

    PubMed

    Brombach, Christoph-Cornelius; Gajdosechova, Zuzana; Chen, Bin; Brownlow, Andrew; Corns, Warren T; Feldmann, Jörg; Krupp, Eva M

    2015-01-01

    Mercury (Hg) is a global pollutant which occurs in different species, with methylmercury (MeHg) being the critical compound due to its neurotoxicity and bioaccumulation through the food chain. Methods for trace speciation of MeHg are therefore needed for a vast range of sample matrices, such as biological tissues, fluids, soils or sediments. We have previously developed an ultra-trace speciation method for methylmercury in water, based on a preconcentration HPLC cold vapour atomic fluorescence spectrometry (HPLC-CV-AFS) method. The focus of this work is mercury speciation in a variety of sample matrices to assess the versatility of the method. Certified reference materials were used where possible, and samples were spiked where reference materials were not available, e.g. human urine. Solid samples were submitted for commonly used digestion or extraction processes to obtain a liquid sample for injection into the analytical system. For MeHg in sediment samples, an extraction procedure was adapted to accommodate MeHg separation from high amounts of Hg(2+) to avoid an overload of the column. The recovery for MeHg determination was found to be in the range of 88-104% in fish reference materials (DOLT-2, DOLT-4, DORM-3), lobster (TORT-2), seaweed (IAEA-140/TM), sediments (ERM(®)-CC580) and spiked urine and has been proven to be robust, reliable, virtually matrix-independent and relatively cost-effective. Applications in the ultra-trace concentration range are possible using the preconcentration up to 200 mL, while for higher MeHg-containing samples, lower volumes can be applied. A comparison was carried out between species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID-GC-ICP-MS) as the gold standard and HPLC-CV-AFS for biological tissues (liver, kidney and muscle of pilot whales), showing a slope of 1.008 and R (2) = 0.97, which indicates that the HPLC-CV-AFS method achieves well-correlated results for MeHg in

  18. Enhanced amperometric detection of metronidazole in drug formulations and urine samples based on chitosan protected tetrasulfonated copper phthalocyanine thin-film modified glassy carbon electrode.

    PubMed

    Meenakshi, S; Pandian, K; Jayakumari, L S; Inbasekaran, S

    2016-02-01

    An enhanced electrocatalytic reduction of metronidazole antibiotic drug molecule using chitosan protected tetrasulfonated copper phthalocyanine (Chit/CuTsPc) thin-film modified glassy carbon electrode (GCE) has been developed. An irreversible reduction occurs at -0.47V (vs. Ag/AgCl) using Chit/CuTsPc modified GCE. A maximum peak current value is obtained at pH1 and the electrochemical reduction reaction is a diffusion controlled one. The detection limit is found to be 0.41nM from differential pulse voltammetry (DPV) method. This present investigation method is adopted for electrochemical detection of metronidazole in drug formulation and urine samples by using DPV method. PMID:26652358

  19. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  20. Preparation of monolithic molecularly imprinted polymer sol-gel packed tips for high-throughput bioanalysis: extraction and quantification of L-tyrosine in human plasma and urine samples utilizing liquid chromatography and tandem mass spectrometry.

    PubMed

    Moein, Mohammad Mahdi; El-Beqqali, Aziza; Abdel-Rehim, Abbi; Jeppsson-Dadoun, Amin; Abdel-Rehim, Mohamed

    2014-09-15

    In situ monolithic molecularly imprinted polymer sol-gel packed tips (MMSTs) were prepared and evaluated for the extraction of lung cancer biomarker L-tyrosine (Tyr) from human plasma and urine samples. Several extraction parameters such as the conditioning, washing and elution solutions, pH and time were investigated. The enrichment factor (EF) and extraction recovery (ER) were studied. MMST showed good selectivity and a high extraction recovery, and MMST as a sorbent showed good stability and repeatability. The method validation showed good regression correlation coefficients for plasma and urine samples (R(2)≥0.996) within the concentration range of 5-1000 and 1-1000 nmol L(-1) in plasma and urine samples, respectively. The lower limits of quantification (LLOQ) in the plasma and urine samples were 5 and 1 nmol L(-1), respectively. The between-batch precision for Tyr in plasma ranged from 1.0 to 6.0%, and in urine it was from 1.0 to 7.0%. The results show that the developed method has more facility, stability, durability and repeatability compared with previous similar methods. To the best of our knowledge, this is the first study aimed at the selective separation of Tyr as a lung cancer biomarker by MMSTs from biological matrixes and detection by LC/MS/MS. PMID:25108365

  1. Urine - abnormal color

    MedlinePlus

    ... straw-yellow. Abnormally colored urine may be cloudy, dark, or blood-colored. Causes Abnormal urine color may ... red blood cells, or mucus in the urine. Dark brown but clear urine is a sign of ...

  2. High-throughput sample preparation and simultaneous column regeneration liquid chromatography-tandem mass spectrometry method for determination of nitrogen mustard metabolites in human urine.

    PubMed

    Reddy, Muntha K; Mills, Grier; Nixon, Christopher; Wyatt, Shane A; Croley, Timothy R

    2011-08-15

    Nitrogen mustards (NMs) are known to have DNA alkylation and strong vesicant properties. Their availability to terrorist organizations makes them a potential choice for chemical attacks on civilian populations. After an exposure, it is difficult to measure NMs directly because of their rapid metabolism in the human body. Therefore to determine an individual's level of exposure to NMs, it is necessary to analyze for NM metabolites being excreted by the body. The metabolites of NMs are generated by a hydrolysis reaction, and are easily detectable by liquid chromatography tandem mass spectrometry (LC-MS/MS). This work is focused on the development of a high-throughput assay for the quantitation of N-ethyldiethanolamine (EDEA) and N-methyldiethanolamine (MDEA) metabolites of bis (2-chloroethyl) ethylethanamine (HN1) and bis (2-chloroethyl) methylethanamine (HN2), respectively. The method uses automated 96-well plate sample preparation of human urine samples and a 2-position 10-port switching valve to allow for simultaneous regeneration of the liquid chromatography (LC) columns. Using this method, over 18 h was saved through the reduction of sample preparation and analysis time when compared to a conventional method for 96 samples. The validated method provided excellent accuracy for both EDEA (100.9%) and MDEA (100.6%) with precision better than 5.27% for each analyte. PMID:21764395

  3. High performance liquid chromatographic determination of ultra traces of two tricyclic antidepressant drugs imipramine and trimipramine in urine samples after their dispersive liquid-liquid microextraction coupled with response surface optimization.

    PubMed

    Shamsipur, Mojtaba; Mirmohammadi, Mehrosadat

    2014-11-01

    Dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography by ultraviolet detection (HPLC-UV) as a fast and inexpensive technique was applied to the determination of imipramine and trimipramine in urine samples. Response surface methodology (RSM) was used for multivariate optimization of the effects of seven different parameters influencing the extraction efficiency of the proposed method. Under optimized experimental conditions, the enrichment factors and extraction recoveries were between 161.7-186.7 and 97-112%, respectively. The linear range and limit of detection for both analytes found to be 5-100ng mL(-1) and 0.6ng mL(-1), respectively. The relative standard deviations for 5ng mL(-1) of the drugs in urine samples were in the range of 5.1-6.1 (n=5). The developed method was successfully applied to real urine sample analyses. PMID:25178259

  4. N-Acetyl-4-aminophenol (paracetamol), N-acetyl-2-aminophenol and acetanilide in urine samples from the general population, individuals exposed to aniline and paracetamol users.

    PubMed

    Dierkes, Georg; Weiss, Tobias; Modick, Hendrik; Käfferlein, Heiko Udo; Brüning, Thomas; Koch, Holger M

    2014-01-01

    Epidemiological studies suggest associations between the use of N-acetyl-4-aminophenol (paracetamol) during pregnancy and increased risks of reproductive disorders in the male offspring. Previously we have reported a ubiquitous urinary excretion of N-acetyl-4-aminophenol in the general population. Possible sources are (1) direct intake of paracetamol through medication, (2) paracetamol residues in the food chain and (3) environmental exposure to aniline or related substances that are metabolized into N-acetyl-4-aminophenol. In order to elucidate the origins of the excretion of N-acetyl-4-aminophenol in urine and to contribute to the understanding of paracetamol and aniline metabolism in humans we developed a rapid, turbulent-flow HPLC-MS/MS method with isotope dilution for the simultaneous quantification of N-acetyl-4-aminophenol and two other aniline related metabolites, N-acetyl-2-aminophenol and acetanilide. We applied this method to three sets of urine samples: (1) individuals with no known exposure to aniline and also no recent paracetamol medication; (2) individuals after occupational exposure to aniline but no paracetamol medication and (3) paracetamol users. We confirmed the omnipresent excretion of N-acetyl-4-aminophenol. Additionally we revealed an omnipresent excretion of N-acetyl-2-aminophenol. In contrast, acetanilide was only found after occupational exposure to aniline, not in the general population or after paracetamol use. The results lead to four preliminary conclusions: (1) other sources than aniline seem to be responsible for the major part of urinary N-acetyl-4-aminophenol in the general population; (2) acetanilide is a metabolite of aniline in man and a valuable biomarker for aniline in occupational settings; (3) aniline baseline levels in the general population measured after chemical hydrolysis do not seem to originate from acetanilide and hence not from a direct exposure to aniline itself and (4) N-acetyl-2-aminophenol does not seem to be

  5. Metabolism and Excretion Rates of Parent and Hydroxy-PAHs in Urine Collected after Consumption of Traditionally Smoked Salmon for Native American Volunteers

    PubMed Central

    Motorykin, Oleksii; Santiago-Delgado, Lisandra; Rohlman, Diana; Schrlau, Jill E.; Harper, Barbara; Harris, Stuart; Harding, Anna; Kile, Molly L.; Massey Simonich, Staci L.

    2015-01-01

    Few studies have been published on the excretion rates of parent polycyclic aromatic hydrocarbons (PAHs) and hydroxy-polycyclic aromatic hydrocarbons (OH-PAHs) following oral exposure. This study investigated metabolism and excretion rates of 4 parent PAHs and 10 OH-PAHs after the consumption of smoked salmon. Nine members of the Confederated Tribes of the Umatilla Indian Reservation consumed 50 g of traditionally smoked salmon with breakfast and five urine samples were collected during the following 24 hours. The concentrations of OH-PAHs increased from 43.9 μg/g creatinine for 2-OH-Nap to 349 ng/g creatinine for 1-OH-Pyr, 3 to 6 hr post-consumption. Despite volunteers following a restricted diet, there appeared to be a secondary source of naphthalene and fluorene, which led to excretion efficiencies greater than 100%. For the parent PAHs that were detected in urine, the excretion efficiencies ranged from 13% for phenanthrene (and its metabolite) to 240% for naphthalene (and its metabolites). The half-lives for PAHs ranged from 1.4 hr for retene to 3.3 hr for pyrene. The half-lives for OH-PAHs were higher and ranged from 1.7 hr for 9-OH-fluorene to 7.0 hr for 3-OH-fluorene. The concentrations of most parent PAHs, and their metabolites, returned to the background levels 24 hr post-consumption. PMID:25659315

  6. Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection.

    PubMed

    Fan, Wenying; He, Man; You, Linna; Zhu, Xuewei; Chen, Beibei; Hu, Bin

    2016-04-22

    Due to the high selectivity and stability, molecularly imprinted polymers (MIPs) have been successfully applied in stir bar sorptive extraction (SBSE) as a special coating to improve the selective extraction capability for target analytes. However, traditional MIPs usually suffer from incompatibility in aqueous media and low adsorption capacity, which limit the application of MIP coated stir bar in aqueous samples. To solve these problems, a water-compatible graphene oxides (GO)/MIP composite coated stir bar was prepared in this work by in situ polymerization. The prepared water-compatible GO/MIP coated stir bar presented good mechanical strength and chemical stability, and its recognition ability in aqueous samples was improved due to the polymerization of MIP in water environment, the adsorption capacity for target analytes was also increased by the addition of GO in MIP pre-polymer solution. Based on it, a method of water-compatible GO/MIP coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detector (HPLV-UV) was proposed for the analysis of propranolol (PRO) in aqueous solution. The influencing factors of SBSE, such as sample pH, salt effect, stirring rate, extraction time, desorption solvent and desorption time, were optimized, and the analytical performance of the developed SBSE-HPLC-UV method was evaluated under the optimized conditions. The limit of detection (LOD) of the proposed method for PRO was about 0.37 μg L(-1), and the enrichment factor (EF) was 59.7-fold (theoretical EF was 100-fold). The reproducibility was also investigated at concentrations of 5 μg L(-1) and the relative standard deviation (RSD) was found to be 7.3% (n=7). The proposed method of GO/MIP coating-SBSE-HPLC-UV was successfully applied for the assay of the interested PRO drug in urine samples, and further extended to the investigation of the excretion of the drugs by monitoring the variation of the concentration of PRO in urine

  7. Determination of γ-hydroxybutyrate (GHB), β-hydroxybutyrate (BHB), pregabalin, 1,4-butane-diol (1,4BD) and γ-butyrolactone (GBL) in whole blood and urine samples by UPLC-MSMS.

    PubMed

    Dahl, Sandra Rinne; Olsen, Kirsten Midtbøen; Strand, Dag Helge

    2012-02-15

    The demand of high throughput methods for the determination of gamma-hydroxybutyrate (GHB) and its precursors gamma-butyrolactone (GBL) and 1,4-butane-diol (1,4BD) as well as for pregabalin is increasing. Here we present two analytical methods using ultra-high pressure liquid chromatography (UPLC) and tandem mass spectrometric (MS/MS) detection for the determination of GHB, beta-hydroxybutyrate (BHB), pregabalin, 1,4BD and GBL in whole blood and urine. Using the 96-well formate, the whole blood method is a simple high-throughput method suitable for screening of large sample amounts. With an easy sample preparation for urine including only dilution and filtration of the sample, the method is suitable for fast screening of urine samples. Both methods showed acceptable linearity, acceptable limits of detection, and limits of quantification. The within-day and between-day precisions of all analytes were lower than 10% RSD. The analytes were extracted from matrices with recoveries near 100%, and no major matrix effects were observed. Both methods have been used as routine screening analyses of whole blood and urine samples since January 2010. PMID:22226469

  8. The Human Urine Metabolome

    PubMed Central

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing

  9. Graphene oxide assisted electromembrane extraction with gas chromatography for the determination of methamphetamine as a model analyte in hair and urine samples.

    PubMed

    Bagheri, Hasan; Zavareh, Alireza Fakhari; Koruni, Mohammad Hossein

    2016-03-01

    In the present study, graphene oxide reinforced two-phase electromembrane extraction (EME) coupled with gas chromatography was applied for the determination of methamphetamine as a model analyte in biological samples. The presence of graphene oxide in the hollow fiber wall can increase the effective surface area, interactions with analyte and polarity of support liquid membrane that leads to an enhancement in the analyte migration. To investigate the influence of the presence of graphene oxide in the support liquid membrane on the extraction efficiency, a comparative study was performed between graphene oxide and graphene oxide/EME methods. The extraction parameters such as type of organic solvent, pH of the donor phase, stirring speed, time, voltage, salt addition and the concentration of graphene oxide were optimized. Under the optimum conditions, the proposed microextraction technique provided low limit of detection (2.4 ng/mL), high preconcentration factor (195-198) and high relative recovery (95-98.5%). Finally, the method was successfully employed for the determination of methamphetamine in urine and hair samples. PMID:26790990

  10. Behavior of Phenols and Phenoxyacids on a Bisphenol-A Imprinted Polymer. Application for Selective Solid-Phase Extraction from Water and Urine Samples

    PubMed Central

    Herrero-Hernández, Eliseo; Carabias-Martínez, Rita; Rodríguez-Gonzalo, Encarnacion

    2011-01-01

    A molecularly imprinted polymer (MIP), obtained by precipitation polymerisation with 4-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate as cross-linker, and bisphenol-A (BPA) as template, was prepared. The binding site configuration of the BPA-MIP was examined using Scatchard analysis. Moreover, the behaviour of the BPA-MIP for the extraction of several phenolic compounds (bisphenol-A, bisphenol-F, 4-nitrophenol, 3-methyl-4-nitrophenol) and phenoxyacid herbicides such as 2,4-D, 2,4,5-T and 2,4,5-TP has been studied in organic and aqueous media in the presence of other pesticides in common use. It was possible to carry out the selective preconcentration of the target analytes from the organic medium with recoveries of higher than 70%. In an aqueous medium, hydrophobic interactions were found to exert a remarkably non-specific contribution to the overall binding process. Several parameters affecting the extraction efficiency of the BPA-MIP were evaluated to achieve the selective preconcentration of phenols and phenoxyacids from aqueous samples. The possibility of using the BPA-MIP as a selective sorbent to preconcentrate these compounds from other samples such as urine and river water was also explored. PMID:21686187

  11. Screening determination of four amphetamine-type drugs in street-grade illegal tablets and urine samples by portable capillary electrophoresis with contactless conductivity detection.

    PubMed

    Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Ta, Thi Thao; Nguyen, Xuan Truong; Nguyen, Thi Lien; Le, Thi Hong Hao; Koenka, Israel Joel; Sáiz, Jorge; Hauser, Peter C; Mai, Thanh Duc

    2015-12-01

    A simple and inexpensive method for the identification of four substituted amphetamines, namely, 3,4-methylenedioxy methamphetamine (MDMA), methamphetamine (MA), 3,4-methylenedioxy amphetamine (MDA) and 3,4-methylenedioxy-N-ethylamphetamine (MDEA) was developed using an in-house constructed semi-automated portable capillary electrophoresis instrument (CE) with capacitively coupled contactless conductivity detection (C(4)D). Arginine 10mM adjusted to pH4.5 with acetic acid was found to be the optimal background electrolyte for the CE-C(4)D determination of these compounds. The best detection limits achieved with and without a sample preconcentration process were 10ppb and 500ppb, respectively. Substituted amphetamines were found in different seized illicit club drug tablets and urine samples collected from different suspected users. Good agreement between results from CE-C(4)D and those with the confirmation method (GC-MS) was achieved, with correlation coefficients for the two pairs of data of more than 0.99. PMID:26654084

  12. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    PubMed

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml. PMID:25542574

  13. Application of ultrasound-assisted emulsification microextraction for simultaneous determination of aminophenol isomers in human urine, hair dye, and water samples using high-performance liquid chromatography.

    PubMed

    Asghari, Alireza; Fazl-Karimi, Hamidreza; Barfi, Behruz; Rajabi, Maryam; Daneshfar, Ali

    2014-08-01

    Aminophenol isomers (2-, 3-, and 4-aminophenols) are typically classified as industrial pollutants with genotoxic and mutagenic effects due to their easy penetration through the skin and membranes of human, animals, and plants. In the present study, a simple and efficient ultrasound-assisted emulsification microextraction procedure coupled with high-performance liquid chromatography with ultraviolet detector was developed for preconcentration and determination of these compounds in human fluid and environmental water samples. Effective parameters (such as type and volume of extraction solvent, pH and ionic strength of sample, and ultrasonication and centrifuging time) were investigated and optimized. Under optimum conditions (including sample volume: 5 mL; extraction solvent: chloroform, 80 µL; pH: 6.5; without salt addition; ultrasonication: 3.5 min; and centrifuging time: 3 min, 5000 rpm min(-1)), the enrichment factors and limits of detection were ranged from 42 to 51 and 0.028 to 0.112 µg mL(-1), respectively. Once optimized, analytical performance of the method was studied in terms of linearity (0.085-157 µg mL(-1), r (2) > 0.998), accuracy (recovery = 88.6- 101.7%), and precision (repeatability: intraday precision < 3.98%, and interday precision < 5.12%). Finally, applicability of the method was evaluated by the extraction and determination of these compounds in human urine, hair dye, and real water samples. PMID:24275645

  14. Comparative Evaluation of the Novel bioNexia Legionella Test with the BinaxNOW Legionella Card Assay and the Sofia Legionella FIA Assay for Detection of Legionella pneumophila (Serogroup 1) Antigen in Urine Samples.

    PubMed

    Congestrì, Francesco; Crepaldi, Elisabetta; Gagliardi, Marina; Pedna, Maria Federica; Sambri, Vittorio

    2016-04-01

    A new immunochromatographic test (bioNexiaLegionella; bioMérieux) for the detection ofLegionella pneumophilaurinary antigen was evaluated in 255 urine samples. The results were compared with those obtained by the BinaxNOW and SofiaLegionellatests. The novel test compared well with those currently in use. PMID:26865691

  15. Can sample treatments based on advanced oxidation processes assisted by high-intensity focused ultrasound be used for toxic arsenic determination in human urine by flow-injection hydride-generation atomic absorption spectrometry?

    PubMed

    Correia, A; Galesio, M; Santos, H; Rial-Otero, R; Lodeiro, C; Oehmen, A; Conceição, Antonio C L; Capelo, J L

    2007-05-15

    Two advanced oxidation processes (AOPs), based on high-intensity focused ultrasound (HIFU), namely, KMnO(4)/HCl/HIFU and H(2)O(2)/HCl/HIFU are studied and compared for the determination of toxic arsenic in human urine [As(III)+As(V)+MMA+DMA] by flow-injection hydride-generation atomic absorption spectrometry (FI-HG-AAS). The KMnO(4)/HCl/HIFU procedure was found to be adequate for organic matter degradation in human urine. l-cysteine (letra minuscula) was used for As reduction to the trivalent state. The new procedure was assessed with seven urines certified in different As species. Results revealed that with KMnO(4)/HCl/HIFU plus l-cysteine the toxic arsenic can be accurately measured in human urine whilst the H(2)O(2)/HCl/HIFU procedure underestimates toxic As. DMA and MMA degradation in urine were observed, due to the effects of the ultrasonic field. Recoveries for As(III), As(V), MMA and DMA were within the certified ranges. Arsenobetaine was not degraded by the AOPs. The new procedure adheres well to the principles of analytical minimalism: (i) low reagent consumption, (ii) low reagent concentration, (iii) low waste production and (iv) low amount of time required for sample preparation and analysis. PMID:19071711

  16. A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip

    PubMed Central

    Balakrishnan, S. R.; Hashim, U.; Gopinath, Subash C. B.; Poopalan, P.; Ramayya, H. R.; Iqbal Omar, M.; Haarindraprasad, R.; Veeradasan, P.

    2015-01-01

    Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU-1 ml-2 cm-2 was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant Kd of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was Bmax = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets. PMID:26368287

  17. A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip.

    PubMed

    Balakrishnan, S R; Hashim, U; Gopinath, Subash C B; Poopalan, P; Ramayya, H R; Iqbal Omar, M; Haarindraprasad, R; Veeradasan, P

    2015-01-01

    Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant Kd of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was Bmax = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets. PMID:26368287

  18. Urinal Dynamics

    NASA Astrophysics Data System (ADS)

    Hurd, Randy; Hacking, Kip; Haymore, Benjamin; Truscott, Tadd; Splash Lab Team

    2013-11-01

    In response to harsh and repeated criticisms from our mothers and several failed relationships with women, we present the splash dynamics of a simulated human male urine stream impacting rigid and free surfaces. Our study aims to reduce undesired splashing that may result from lavatory usage. Experiments are performed at a pressure and flow rate that would be expected from healthy male subjects. For a rigid surface, the effects of stream breakup and surface impact angle on lateral and vertical droplet ejection distances are measured using high-speed photography and image processing. For free surface impact, the effects of velocity and fluid depth on droplet ejection distances are measured. Guided by our results, techniques for splash reduction are proposed.

  19. Preconcentration of valsartan by dispersive liquid-liquid microextraction based on solidification of floating organic drop and its determination in urine sample: Central composite design.

    PubMed

    Pebdani, Arezou Amiri; Shabani, Ali Mohammad Haji; Dadfarnia, Shayesteh; Talebianpoor, Mohammad Sharif; Khodadoust, Saeid

    2016-05-01

    In this work, a fast, easy, and efficient dispersive liquid-liquid microextraction method based on solidification of floating organic drop followed by high-performance liquid chromatography with UV detection was developed for the separation/preconcentration and determination of the drug valsartan. Experimental design was applied for the optimization of the effective variables (such as volume of extracting and dispersing solvents, ionic strength, and pH) on the extraction efficiency of valsartan from urine samples. The optimized values were 250.0 μL ethanol, 65.0 μL 1-dodecanol, 4.0% w/v NaCl, pH 3.8, 1.0 min extraction time, and 4.0 min centrifugation at 4000 rpm min(-1) . The linear response (r(2) = 0.997) was obtained in the range of 0.013-10.0 μg mL(-1) with a limit of detection of 4.0 ng mL(-1) and relative standard deviations of less than 5.0 % (n = 6). PMID:26991865

  20. Codetection of Trichomonas vaginalis and Candida albicans by PCR in Urine Samples in a Low-Risk Population Attended in a Clinic First Level in Central Veracruz, Mexico

    PubMed Central

    López-Monteon, A.; Gómez-Figueroa, F. S.; Ramos-Poceros, G.; Guzmán-Gómez, D.; Ramos-Ligonio, A.

    2013-01-01

    The aim of this study is to estimate the prevalence of Trichomonas vaginalis and Candida albicans in low-risk patients treated at a first level clinic (primary health care represents the first level of contact of individuals, families, and the community with the system national health). Using a cross-sectional study in patients treated in clinical laboratory of the Sanitary District no. 7 of the city of Orizaba during the months June-July, 252 urine samples were collected for the identification of T. vaginalis and C. albicans by PCR. Furthermore, we analyzed the sociodemographic characteristics of the studied population. We observed an overall prevalence of 23.41% (95% CI 22.10–24.72) for T. vaginalis and 38.88% (95% CI 37.73–40.03) for C. albicans. There was also presence of coinfection in 14.28% (95% CI 13.10–15.46), which was associated with the presence of pain. Most of the positive cases were observed in women house-maker (80%, 95% CI 50.36–48.98). The results of this study provide evidence that the majority of positive cases observed in the studied population are presented in an asymptomatic form and usually are not associated with any risk factor. PMID:24069593

  1. Preconcentration and spectrophotometric determination of oxymetholone in the presence of its main metabolite (mestanolone) using modified maghemite nanoparticles in urine sample.

    PubMed

    Madrakian, Tayyebeh; Afkhami, Abbas; Rahimi, Mohammad; Ahmadi, Mazaher; Soleimani, Mohammad

    2013-10-15

    A novel and sensitive extraction procedure using maghemite nanoparticles (γ-Fe2O3) modified with sodium dodecyl sulfate (SDS), as an efficient solid phase, was developed for removal, preconcentration and spectrophotometric determination of trace amounts of oxymetholone (OXM), in the presence of mestanolone (MSL). Combination of nanoparticle adsorption and easily magnetic separation was used for the extraction and desorption of OXM. The preparation of γ-Fe2O3 nanoparticles were obtained by co-precipitation method and their surfaces were modified by SDS. The size and properties of the produced γ-Fe2O3 nanoparticles were determined by X-ray diffraction analysis, FT-IR and scanning electron microscopy measurements. OXM and MSL became adsorbed at pH 3.0. The adsorbed drugs were then desorbed and determined spectrophotometrically using a selective complexation reaction for OXM. The calibration graph was linear in the range 15.0-3300.0 ng mL(-1) of OXM with a correlation coefficient of 0.9948. The detection limit of the method for determination of OXM was 4.0 ng mL(-1). The method was applied for the determination of OXM in human urine samples. PMID:24054620

  2. A fully automated effervescence-assisted switchable solvent-based liquid phase microextraction procedure: Liquid chromatographic determination of ofloxacin in human urine samples.

    PubMed

    Vakh, Christina; Pochivalov, Aleksei; Andruch, Vasil; Moskvin, Leonid; Bulatov, Andrey

    2016-02-11

    A novel fully automated effervescence-assisted switchable solvent-based liquid phase microextraction procedure has been suggested. In this extraction method, medium-chain saturated fatty acids were investigated as switchable hydrophilicity solvents. The conversion of fatty acid into hydrophilic form was carried out in the presence of sodium carbonate. The injection of sulfuric acid into the solution decreased the pH value of the solution, thus, microdroplets of the fatty acid were generated. Carbon dioxide bubbles were generated in-situ, and promoted the extraction process and final phase separation. The performance of the suggested approach was demonstrated by the determination of ofloxacin in human urine samples using high-performance liquid chromatography with fluorescence detection. This analytical task was used as a proof-of-concept example. Under the optimal conditions, the detector response of ofloxacin was linear in the concentration ranges of 3·10(-8)-3·10(-6) mol L(-1). The limit of detection, calculated from a blank test based on 3σ, was 1·10(-8) mol L(-1). The results demonstrated that the presented approach is highly cost-effective, simple, rapid and environmentally friendly. PMID:26803002

  3. Urine specific gravity test

    MedlinePlus

    Urine specific gravity is a laboratory test that shows the concentration of all chemical particles in the urine. ... changes to will tell the provider the specific gravity of your urine. The dipstick test gives only ...

  4. Urination - difficulty with flow

    MedlinePlus

    ... at night? Has the force of your urine flow decreased? Do you have dribbling or leaking urine? ... conditions or surgeries that could affect your urine flow? What medicines do you take? Tests that may ...

  5. Gas chromatography-mass spectrometry determination of pharmacologically active substances in urine and blood samples by use of a continuous solid-phase extraction system and microwave-assisted derivatization.

    PubMed

    Azzouz, Abdelmonaim; Ballesteros, Evaristo

    2012-04-01

    A sensitive method based on gas chromatography-mass spectrometry was used to determine 22 pharmacologically active substances (frequently used in the treatment of human and animal's diseases) including analgesics, antibacterials, anti-epileptics, antiseptics, β-blockers, hormones, lipid regulators and non-steroidal anti-inflammatories in blood and urine samples. Samples were subjected to continuous solid-phase extraction in a sorbent column (Oasis HLB), and then the target analytes were eluted with ethyl acetate and derivatized in a household microwave oven at 350 W for 3 min. Finally, these products were determined in a gas chromatograph-mass spectrometer equipped with a DB-5 fused silica capillary column. The analyte detection limits thus obtained ranged from 0.2 to 1.3 ng L⁻¹ for urine samples and 0.8-5.6 ng L⁻¹ for blood samples. Recoveries from both blood and urine ranged from 85 to 102%, and within-day and between-day relative standard deviations were all less than 7.5%. The proposed method offers advantages in reduction of the exposure danger to toxic solvents used in conventional sample pretreatment, simplicity of the extraction processes, rapidity, and sensitivity enhancement. The method was successfully used to quantify pharmacologically active substances in human and animal (lamb, veal and pig) blood and urine. The hormones estrone and 17β-estradiol were detected in virtually all samples, and so were other analytes such as acetylsalicylic acid, ibuprofen, ketoprofen and triclosan in human samples, and florfenicol, pyrimethamine and phenylbutazone in animal samples. PMID:22391330

  6. Urine Protein and Urine Protein to Creatinine Ratio

    MedlinePlus

    ... limited. Home Visit Global Sites Search Help? Urine Protein and Urine Protein to Creatinine Ratio Share this page: Was this page helpful? Also known as: 24-Hour Urine Protein; Urine Total Protein; Urine Protein to Creatinine Ratio; ...

  7. Sunlight assisted synthesis of silver nanoparticles in zeolite matrix and study of its application on electrochemical detection of dopamine and uric acid in urine samples.

    PubMed

    Meenakshi, S; Devi, S; Pandian, K; Devendiran, R; Selvaraj, M

    2016-12-01

    Sunlight assisted reduction of silver ions were accomplished for the synthesis of silver nanoparticles incorporated within the mesoporous silicate framework of zeolite Y. The zeolite-Y and AgNP/Zeo-Y were characterized by field emission scanning electron microscopy, transmission electron microscopy, N2 adsorption-desorption BET isotherm and X-ray diffraction techniques. The incorporation of silver nanoparticles within the porous framework was further confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. An enhanced electrocatalytic oxidation of biologically important molecules like dopamine and uric acid using AgNP/Zeo-Y modified glassy carbon electrode has been developed. A simultaneous oxidation of DA and UA peaks were obtained at +0.31V and +0.43V (vs. Ag/AgCl) using AgNP/Zeo-Y/GCE under the optimum experimental condition. A well-resolved peak potential window (~120mV) for the oxidation of both DA and UA were observed at AgNP/Zeo-Y/GCE system. The calibration curves for DA and UA were obtained within the dynamic linear range of 0.02×10(-6) to 0.18×10(-6)M (R(2)=0.9899) and 0.05×10(-6) to 0.7×10(-6)M (R(2)=0.9996) and the detection limits were found to be 1.6×10(-8)M and 2.51×10(-8)M by using differential pulse voltammetry (DPV) method. The proposed method was successfully applied for the determination of both DA and UA in human urine samples with a related standard deviation was <3%, and n=5 using the standard addition method. PMID:27612692

  8. A retrospective study of the changing trends of antimicrobial resistance of Klebsiella pneumoniae isolated from urine samples over last 3 years (2012-2014)

    PubMed Central

    Sharma, Neetu; Gupta, Anita K.; Walia, Geeta; Bakhshi, Rupinder

    2016-01-01

    Background: In our country, the problem of antibiotic resistance is compounding because of overuse and misuse of antibiotics. There is no systematic national surveillance of antibiotic resistance and insufficient data are available to quantify the problem. Objectives: To study the changing pattern of antimicrobial resistance of Klebsiella pneumoniae isolates from patients of urinary tract infections over last 3 years. Materials and Methods: A retrospective, record-based study carried out based on the records culture sensitivity reports of indoor patients, during past 3 years (2012-2014). The type of organisms most common in urine sample was noted, and the drugs still effective for the particular organism were noted. Results: Klebsiella was the second most frequent isolate throughout the 3 years (14%) of the total isolates). Analysis of the results year wise indicated that the lowest percentage of resistance was manifested against imipenem between 11.94% (2012) and 13.75% (2014). Over the successive years, resistance to ceftriaxone tends to increase from 74.95 % (2012) to 81% (2014). Klebsiella showed very high resistance 90.78% (2012) and 95.63% (2012) to co-trimoxazole and tetracycline, respectively with increasing trend to absolute resistance to both groups over the 3 years period. On an average over the 3 years Klebsiella showed a high amount of resistances to fluoroquinolones (72.71%) and aminoglycosides (76.22%). While multi-drug resistant Klebsiella range between 65% (2012) and 67% (2014). Conclusion: The antimicrobial resistance patterns are constantly evolving and vary from region to region it has become a necessity to do constant antimicrobial sensitivity surveillance. This will help clinicians to provide safe and effective empirical therapies. PMID:27003967

  9. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples

    PubMed Central

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907

  10. Frequency of Plasmid-Mediated AmpC β-Lactamases in Escherichia coli Isolates from Urine Samples in São Paulo, Brazil.

    PubMed

    Rocha, Darlan Augusto Costa; Campos, Juliana Coutinho; Passadore, Lilian Ferri; Sampaio, Suely Carlos Ferreira; Nicodemo, Antonio Carlos; Sampaio, Jorge Luiz Mello

    2016-06-01

    Plasmid-mediated AmpC β-lactamases (PMACBLs) in Enterobacteriaceae encode resistance to third-generation cephalosporins, and these can mediate carbapenem resistance when associated with porin loss. However, no standardized phenotypic method is available for detecting these enzymes in the clinical microbiology laboratory. Limited data are available concerning the frequency of PMACBLs in Enterobacteriaceae in Brazil. This study was conducted in response to an increased cefoxitin (CFO) resistance rate of 3.7% in Escherichia coli isolates from urine samples from patients with suspected urinary tract infections during 2010. We collected 2,266 E. coli isolates prospectively during January 2012. A total of 109 (4.8%) isolates were nonsusceptible to CFO. These strains were further examined using multiplex PCR for the presence of genes encoding PMACBLs and using inhibitor assays with CFO and ceftazidime (CAZ) disks with and without phenylboronic acid. Pulsed-field gel electrophoresis was used to evaluate clonal dissemination. Genes encoding PMACBLs were detected in 1.8% of the isolates from inpatients and 0.46% of isolates from outpatients. The most prevalent gene was blaCMY-2 and blaCMY-4 was also detected. The phenotypic analysis showed 100% sensitivity and specificity for CMY-2 and CMY-4 when CFO-resistant isolates with a minimum zone diameter difference of 5 mm for CAZ or CAZ and CFO were considered positive. Although most of the isolates were nonclonal, one clonal group with two isolates was observed. Thus, the most frequent PMACBL in E. coli from São Paulo, Brazil is CMY-2, and both clonal and plasmid-mediated dissemination occur. PMID:26670152

  11. Validation and application of an UPLC-MS/MS method for the quantification of synthetic cannabinoids in urine samples and analysis of seized materials from the Portuguese market.

    PubMed

    Simões, Susana Sadler; Silva, Inês; Ajenjo, Antonio Castañera; Dias, Mário João

    2014-10-01

    An UPLC-MS/MS method using ESI+ionization and MRM was developed and fully validated according to international guidelines for the qualitative and quantitative analysis of nine synthetic cannabinoids and/or their metabolites in urine samples (1mL). Prior to extraction the samples were subjected to an enzymatic hydrolysis using β-glucuronidase followed by a SPE procedure using Oasis(®) HLB 3cc (60mg) columns. The chromatographic separation was performed with an Acquity UPLC(®) HSS T3 (50mm×2.1mm i.d., 1.8μm) reversed-phase column using a gradient with methanol-ammonium formate 2mM (0.1% formic acid) and with a run time of 9.5min. The method was validated in terms of selectivity, capacity of identification, limits of detection (0.01-0.5ng/mL) and quantification (0.05-0.5ng/mL), recovery (58-105%), carryover, matrix effect, linearity (0.05-50ng/mL), intra-assay precision, inter-assay accuracy and precision (CV<20%). The method was applied to 80 authentic samples, five of them (6.2%) were confirmed or suspected to be positive for the metabolites JWH-018 N-hydroxypentyl and JWH-018 N-pentanoic acid of JWH-018 and for the metabolite JWH-122 N-(5-hydroxypentyl) of JWH-122, and three of them in association with THC and/or THCCOOH (substances included in the method, together with the 11-OH-THC). Additionally, 17 spice products were analyzed, for which were confirmed the presence of the following substances: AM-2201, JWH-018, JWH-022 JWH-073, JWH-122, JWH-203, JWH-210, JWH-250, HU-210 and RCS-4, according to the comparison with authentic reference material and published data. The analytical method developed allowed the analysis of synthetic cannabinoids and the notification of the first cases in Portugal. PMID:25127518

  12. [Bacterial contamination of infant urine samples obtained from filter papers used in neuroblastoma-screening tests. (6) Protective effects of preaddition of chlorhexidine digluconate in filter papers or containers for urine on bacterial break-down of creatinine, vanillylmandelic acid and homovanillic acid].

    PubMed

    Imai, J; Iwata, H; Gotoh, K; Mori, H; Kawai, M

    1992-10-01

    The effects of chlorhexidine digluconate preadded to urine samples for a neuroblastoma-screening test in preventing the break-down of creatinine (Cre), vanillylmandelic acid (VMA), and homovanillic acid (HVA) by creatinine-cleaving bacteria and the influence of the added disinfectant on the HPLC determination of urinary Cre, VMA, vanillillactic acid (VLA) and HVA. Laboratory or field experiments showed that preadded disinfectant (0.02% volume) nearly completely inhibited the growth of the bacteria and satisfactorily protected urinary Cre, VMA, and HVA from bacterial decomposition. Chlorhexidine digluconate was comparable to benzalkonium chloride in its inhibitory effects on the growth and activities of creatinine-cleaving bacteria. Unlike benzalkonium chloride, chlorhexidine digluconate added to urine samples gave no troubles in subsequent analytical processes. Addition of the disinfectant (0.02% volume) to standard Cre, VMA, VLA, and HVA solution did not affect retention times and sensitivities in HPLC analyses. To estimate influences of the added disinfectant on the serial HPLC determinations of VMA, VLA, and HVA on a large number of urine samples (40, 80, 120, 160, 200, or 5, 500), HPLC analyses were performed on standard VMA, VLA, and HVA solution with repeated injection of the disinfectant in great amounts into a column. The results showed no appreciable changes in the retention times and sensitivities of VMA, VLA, and HVA, and almost complete elution of the disinfectant retained on the column were possible with water-methanol (1:1, 2:8) or methanol washing.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1467545

  13. Pre-analytical and analytical validations and clinical applications of a miniaturized, simple and cost-effective solid phase extraction combined with LC-MS/MS for the simultaneous determination of catecholamines and metanephrines in spot urine samples.

    PubMed

    Li, Xiaoguang Sunny; Li, Shu; Kellermann, Gottfried

    2016-10-01

    It remains a challenge to simultaneously quantify catecholamines and metanephrines in a simple, sensitive and cost-effective manner due to pre-analytical and analytical constraints. Herein, we describe such a method consisting of a miniaturized sample preparation and selective LC-MS/MS detection by the use of second morning spot urine samples. Ten microliters of second morning urine sample were subjected to solid phase extraction on an Oasis HLB microplate upon complexation with phenylboronic acid. The analytes were well-resolved on a Luna PFP column followed by tandem mass spectrometric detection. Full validation and suitability of spot urine sampling and biological variation were investigated. The extraction recovery and matrix effect are 74.1-97.3% and 84.1-119.0%, respectively. The linearity range is 2.5-500, 0.5-500, 2.5-1250, 2.5-1250 and 0.5-1250ng/mL for norepinephrine, epinephrine, dopamine, normetanephrine and metanephrine, respectively. The intra- and inter-assay imprecisions are ≤9.4% for spiked quality control samples, and the respective recoveries are 97.2-112.5% and 95.9-104.0%. The Deming regression slope is 0.90-1.08, and the mean Bland-Altman percentage difference is from -3.29 to 11.85 between a published and proposed method (n=50). A correlation observed for the spot and 24h urine collections is significant (n=20, p<0.0001, r: 0.84-0.95, slope: 0.61-0.98). No statistical differences are found in day-to-day biological variability (n=20). Reference intervals are established for an apparently healthy population (n=88). The developed method, being practical, sensitive, reliable and cost-effective, is expected to set a new stage for routine testing, basic research and clinical applications. PMID:27474304

  14. Preparation of water stable methyl-modified metal-organic framework-5/polyacrylonitrile composite nanofibers via electrospinning and their application for solid-phase extraction of two estrogenic drugs in urine samples.

    PubMed

    Asiabi, Mina; Mehdinia, Ali; Jabbari, Ali

    2015-12-24

    The nanofibers of methyl-modified metal-organic framework-5/polyacrylonitrile composite (CH3MOF-5/PAN) were successfully synthesized and used as a solid-phase extraction (SPE) sorbent for pre-concentration of two estrogenic drugs, levonorgestrel and megestrol acetate, in urine samples. A simple, cheap and accessible electrospinning method was employed to prepare a water stable CH3MOF-5/PAN composite. The nanofibers were packed into the mini-disc cartridges to be used as SPE devices. They were also characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, X-ray diffraction and N2 adsorption-desorption experiments. The effects of different parameters influencing the extraction efficiency including the type of eluent and its volume, the amount of the sorbent, pH, the ionic strength, the sample volume and the reusability of the sorbent were investigated and optimized. Under the optimized conditions, the linearity varied in range of 0.05-100μgL(-1) with R(2) values higher than 0.999. The limit of detection for both of the analytes was 0.02μgL(-1). The applicability of the method was examined by analyzing the analytes in the urine samples. The recovery of the analytes varied in the range of 82.8-94.8% which shows capability of the method for the determination of the drugs in the urine samples. PMID:26639216

  15. Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject.

    PubMed

    Zhao, Yang; Chen, Hui-Jun; Caritis, Steve; Venkataramanan, Raman

    2016-02-01

    A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. PMID:26053159

  16. Screening and confirmation of thyreostatics in urine by gas chromatography with nitrogen-phosphorus detection and gas chromatography-mass spectrometry after sample clean-up with a mercurated affinity column.

    PubMed

    Schilt, R; Weseman, J M; Hooijerink, H; Korbee, H J; Traag, W A; van Steenbergen, M J; Haasnoot, W

    1989-04-01

    Methods are described for the screening and confirmation of residues of the thyreostatics thiouracil, methylthiouracil and propylthiouracil in urine samples of cattle at levels down to 25 micrograms/l. After a selective preconcentration of the thiol-containing thyreostatics on a mercurated affinity column, the analytes are derivatized by extractive alkylation and analysed by gas chromatography with nitrogen-phosphorus or mass spectrometric detection. PMID:2745644

  17. Membrane supported liquid-liquid-liquid microextraction combined with field-amplified sample injection CE-UV for high-sensitivity analysis of six cardiovascular drugs in human urine sample.

    PubMed

    Zhou, Xiaoqing; He, Man; Chen, Beibei; Yang, Qing; Hu, Bin

    2016-05-01

    An effective dual preconcentration method involving off-line membrane supported liquid-liquid-liquid microextraction (MS-LLLME) and on-line field-amplified sample injection (FASI) was proposed for the extraction of six cardiovascular drugs, including mexiletine, xylocaine, propafenone, propranolol, metoprolol, and carvedilol from aqueous solution prior to CE-UV. In MS-LLLME, the analytes were extracted from 9 mL sample solution into toluene, and then back extracted into a drop of acceptor phase of 10 μL 20 mmol/L acetic acid. After that, the acceptor phase was directly introduced into CE for FASI without any modification. In FASI process, water plug was hydrodynamically injected (50 mbar, 3 s) into the capillary prior to sample injection (+6 kV, 18 s). Six target analytes were separated in less than 10 min at 25°C with a BGE consisting of 70 mmol/L Tris-H3 PO4 (pH 2.2) containing 10% v/v methanol. Under the optimized conditions, LODs obtained by the proposed MS-LLLME-FASI-CE-UV method were in the range of 0.02-0.82 μg/L (based on S/N = 3) with enrichment factors of 546- to 7300-fold for the target analytes. The RSDs of the developed method were in the range of 6.7-12.9% (n = 7). Good linearity (R(2) = 0.9928-0.9997) was obtained in concentration range of 0.1-100 μg/L for mexiletine and propranolol, 0.2-100 μg/L for xylocaine and metoprolol, 0.5-100 μg/L for propafenone and 2.0-100 μg/L for carvedilol, respectively. The developed method was successfully applied for real-time determination of metoprolol in human urine samples within 26 h after uptake. PMID:26763094

  18. Isotope concentrations from 24-h urine and 3-h serum samples can be used to measure intestinal magnesium absorption in postmenopausal women

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Studies suggest a link between magnesium status and osteoporosis. One barrier to more conclusive research on the potential relation is measuring intestinal magnesium absorption (MgA), which requires the use of stable isotopes and a >/= 6-d stool or 3-d urine collection. We evaluated alternative meth...

  19. Clinical validation of hrHPV testing on vaginal and urine self-samples in primary cervical screening (cross-sectional results from the Papillomavirus Dumfries and Galloway—PaVDaG study)

    PubMed Central

    Stanczuk, Grazyna; Currie, Heather; Lawrence, James; Cuschieri, Kate; Wilson, Allan; Arbyn, Marc

    2016-01-01

    Objectives Papillomavirus Dumfries and Galloway (PaVDaG) assessed the performance of a high-risk human papillomavirus (hrHPV) PCR-based assay to detect high-grade cervical intraepithelial neoplasia (CIN2+) in self-collected vaginal and urine samples. Setting Women attending routine cervical screening in primary care. Participants 5318 women aged 20–60 years provided self-collected random urine and vaginal samples for hrHPV testing and a clinician-collected liquid-based cytology (LBC) sample for cytology and hrHPV testing. Interventions HrHPV testing. All samples were tested for hrHPV using the PCR-based cobas 4800 assay. Colposcopy was offered to women with high-grade or repeated borderline/low-grade cytological abnormalities; also to those who were LBC negative but hrHPV 16/18 positive. Primary and secondary outcome measures The self-tests' absolute sensitivity and specificity for CIN2+ were assessed on all biospecimens; also, their relative sensitivity and specificity compared with clinician-taken samples. Interlaboratory and intralaboratory performance of the hrHPV assay in self-collected samples was also established. Results HrHPV prevalence was 14.7%, 16.6% and 11.6% in cervical, vaginal and urine samples, respectively. Sensitivity for detecting CIN2+ was 97.7% (95% to 100%), 94.6% (90.7% to 98.5%) and 63.1% (54.6% to 71.7%) for cervical, vaginal and urine hrHPV detection, respectively. The corresponding specificities were 87.3% (86.4% to 88.2%), 85.4% (84.4% to 86.3%) and 89.8% (89.0% to 90.7%). There was a 38% (24% to 57%) higher HPV detection rate in vaginal self-samples from women over 50 years compared with those ≤29 years. Relative sensitivity and specificity of hrHPV positivity for the detection of CIN2+ in vaginal versus cervical samples were 0.97 (0.94 to 1.00) and 0.98 (0.97 to 0.99); urine versus cervical comparisons were 0.53 (0.42 to 0.67) and 1.03 (1.02 to 1.04). The intralaboratory and interlaboratory agreement for hrHPV positivity in

  20. Time Trends of Polycyclic Aromatic Hydrocarbon Exposure in New York City from 2001 to 2012: Assessed by Repeat Air and Urine Samples

    PubMed Central

    Jung, Kyung Hwa; Liu, Bian; Lovinsky-Desir, Stephanie; Yan, Beizhan; Camann, David; Sjodin, Andreas; Li, Zheng; Perera, Frederica; Kinney, Patrick; Chillrud, Steven; Miller, Rachel L.

    2014-01-01

    Background Exposure to air pollutants including polycyclic aromatic hydrocarbons (PAH), and specifically pyrene from combustion of fuel oil, coal, traffic and indoor sources, has been associated with adverse respiratory health outcomes. However, time trends of airborne PAH and metabolite levels detected via repeat measures over time have not yet been characterized. We hypothesized that PAH levels, measured repeatedly from residential indoor and outdoor monitors, and children’s urinary concentrations of PAH metabolites, would decrease following policy interventions to reduce traffic-related air pollution. Methods Indoor PAH (particle- and gas-phase) were collected for two weeks prenatally (n=98), at age 5/6 years (n=397) and age 9/10 years (n=198) since 2001 and at all three age-points (n=27). Other traffic-related air pollutants (black carbon and PM2.5) were monitored indoors simultaneous with PAH monitoring at ages 5/6 (n=403) and 9/10 (n=257) between 2005 and 2012. One third of the homes were selected across seasons for outdoor PAH, BC and PM2.5 sampling. Using the same sampling method, ambient PAH, BC and PM2.5 also were monitored every two weeks at a central site between 2007 and 2012. PAH were analyzed as semivolatile PAH (e.g., pyrene; MW 178–206) and the sum of eight nonvolatile PAH (Σ8PAHnonvolatile; MW 228–278). A spot urine sample was collected from children at child ages 3, 5, 7 and 9 between 2001 and 2012 and analyzed for 10 PAH metabolites. Results Modest declines were detected in indoor BC and PM2.5 levels between 2005 and 2012 (Annual percent change [APC]=−2.08% [p=0.010] and −2.18% [p=0.059] for BC and PM2.5, respectively), while a trend of increasing pyrene levels was observed in indoor and outdoor samples, and at the central site during the comparable time periods (APC=4.81%, 3.77% and 7.90%, respectively; p<0.05 for all). No significant time trend was observed in indoor Σ8PAHnonvolatile levels between 2005 and 2012; however

  1. Quantitative determination of 8-isoprostaglandin F(2α) in human urine using microfluidic chip-based nano-liquid chromatography with on-chip sample enrichment and tandem mass spectrometry.

    PubMed

    Bai, Hsin-Yu; Lin, Shu-Ling; Chung, Yu-Ting; Liu, Tsung-Yun; Chan, Shan-An; Fuh, Ming-Ren

    2011-04-15

    Urinary 8-isoprostaglandin F(2α) (8-isoPGF(2α)) has been reported as an important biomarker to indicate the oxidative stress status in vivo. In order to quantitatively determine the low contents of 8-isoPGF(2α) (in sub- to low ng mL(-1) range) in physiological fluids, a sensitive detection method has become an important issue. In this study, we employed a microfluidic chip-based nano liquid chromatography (chip-nanoLC) with on-chip sample enrichment coupled to triple quadrupole mass spectrometer (QqQ-MS) for the quantitative determination of 8-isoPGF(2α) in human urine. This chip-nanoLC unit integrates a microfluidic switch, a chip column design having a pre-column (enrichment column) for sample enrichment prior to an analytical column for separation, as well as a nanospray emitter on a single polyimide chip. The introduction of enrichment column offers the advantages of online sample pre-concentration and reducing matrix influence on MS detection to improve sensitivity. In this study, the chip-nanoLC consisting of Zorbax 300A SB-C18 columns and Agilent QqQ Mass spectrometer were used for determining 8-isoPGF(2α) in human urine. Gradient elution was employed for effective LC separation and multiple reaction monitoring (MRM) was utilized for the quantitative determination of 8-isoPGF(2α) (m/z 353→193). We employed liquid-liquid extraction (LLE)/solid-phase extraction (SPE) for extracting analyte and reducing matrix effect from urine sample prior to chip-nanoLC/QqQ-MS analysis for determining urinary 8-isoPGF(2α). Good recoveries were found to be in the range of 83.0-85.3%. The linear range was 0.01-2 ng mL(-1) for urinary 8-isoPGF(2α). In addition, the proposed method showed good precision and accuracy for 8-isoPGF(2α) spiked synthetic urine samples. Intra-day and inter-day precisions were 1.8-5.0% and 4.3-5.8%, respectively. The method accuracy for intra-day and inter-day assays ranged from 99.3 to 99.9% and 99.4 to 99.7%, respectively. Due to its

  2. The minimal metabolism of inhaled 1,1,1,2-tetrafluoroethane to trifluoroacetic acid in man as determined by high sensitivity 19F nuclear magnetic resonance spectroscopy of urine samples.

    PubMed

    Monté, S Y; Ismail, I; Mallett, D N; Matthews, C; Tanner, R J

    1994-12-01

    In this work, oxidative metabolism of the new propellant, 1,1,1,2-tetrafluoroethane to trifluoroacetic acid in man is shown to be minimal. Alternative propellants and refrigerants are under development to replace the currently used chlorofluorocarbons which lead to stratospheric ozone depletion. One potentially useful replacement is the hydrofluorocarbon, 1,1,1,2-tetrafluoroethane (HFA-134a). Before it can be used, however, particularly as a propellant in an aerosol pharmaceutical formulation whereby the compound is in effect dosed to people, it is important that the safety of this compound is established. As a part of this safety evaluation it is necessary to understand the metabolism of HFA-134a. In this work the production of the potential oxidative metabolite of HFA-134a, trifluoroacetic acid (TFA) has been studied in human urine following inhalation dosing with HFA-134a. The concentrations of TFA in urine have been measured using a highly sensitive 19F nuclear magnetic resonance procedure with a limit of detection of 10 ng ml-1 based on an acquisition time of only 2.25 h per sample. TFA is the only fluorinated species observed in the urine samples and only at very low levels, indicating that the oxidative route of metabolism can occur in vivo in man, but this metabolism is minimal in terms of percentage of administered dose. PMID:7696372

  3. Simultaneous derivatization and solid-based disperser liquid-liquid microextraction for extraction and preconcentration of some antidepressants and an antiarrhythmic agent in urine and plasma samples followed by GC-FID.

    PubMed

    Farajzadeh, Mir Ali; Khorram, Parisa; Ghorbanpour, Houshang

    2015-03-01

    The present work is based on a one-step method including derivatization and solid-based disperser liquid-liquid microextraction followed by gas chromatography-flame ionization detection (GC-FID) for the determination of four antidepressants (fluoxetine, fluvoxamine, tranylcypromine, and nortriptyline) and an antiarrhythmic agent (mexiletine) in human urine and plasma samples. In this method, a mixture of 1,1,2,2-tetrachloroethane (extraction solvent) and butylchloroformate (derivatizing reagent) is added on a sugar cube (solid disperser) and it is introduced into an aqueous sample containing the analytes and a catalyst, e.g. 3-methylpyridine (picoline). During dissolving the sugar cube by manual shaking, the extractant and derivatization agent are gradually released into the sample as very fine droplets. Then the resulted cloudy solution is centrifuged and the sedimented phase is analyzed by GC-FID. The influence of several variables on the efficiency of derivatization/microextraction procedure such as kind and volume of extraction solvent, type and amount of disperser, amount of derivatization agent, and catalyst volume are optimized. Under the optimum conditions the calibration curves are linear in the range of 8-100,000μgL(-1) (coefficient of determination ≥0.994). The relative standard deviations are obtained in the range of 3.0-6.0% for all compounds. Moreover, the detection limits and enrichment factors of the target analytes are obtained in the ranges 1-15μgL(-1) and 228-268, respectively, for both plasma and urine samples. The relative recoveries obtained for the spiked plasma and urine samples are between 70 and 91%. The results show that the proposed method is simple, reliable, low cost, and applicable to determine trace amounts of the studied drugs in biological samples. PMID:25618251

  4. A new analytical method based on anti-EPO monolith column and LC-FAIMS-MS/MS for the detection of rHuEPOs in horse plasma and urine samples.

    PubMed

    Bailly-Chouriberry, Ludovic; Cormant, Florence; Garcia, Patrice; Lönnberg, Maria; Szwandt, Simon; Bondesson, Ulf; Popot, Marie-Agnès; Bonnaire, Yves

    2012-05-21

    Recombinant human erythropoietin (rHuEPO) is a 30-34 kDa glycoprotein banned by the racing authorities. For some years this molecule has been detected in race horses in USA and in Europe, and even in racing camels. Although direct methods to differentiate horse endogenous EPO and rHuEPO have been developed either by LC-MS/MS or by isoelectric focusing (IEF) with double-blotting, the short confirmation time of such prohibited hormone in plasma remains a problem for horseracing doping control laboratories. In order to improve the rHuEPOs confirmation process in horse plasma or urine in terms of reliability and delay, a small anti-EPO monolith membrane contained in a disposable column (anti-EPO monolith column) has been successfully used and validated (n = 10). This new sample preparation, combined with LC-FAIMS-MS/MS, has been performed on plasma and urine samples collected from one horse which received an Eprex® treatment during six consecutive days and a second one with a single injection of Aranesp®. This inventive technology allowed the possibility to confirm the presence of rHuEPO within one day with a limit of detection validated for both urine and plasma at 250 pg mL(-1) by means of a disposable, ready to use immunoaffinity column. The lower limit of detection (LLOD) obtained for each matrix was 100 pg mL(-1). These results provide an important improvement for rHuEPO doping control in horseracing especially the possibility to confirm these banned molecules in both matrices, urine and plasma, with a confidence of two specific target peptides. PMID:22454833

  5. Advances in Urine Microscopy.

    PubMed

    Becker, Gavin J; Garigali, Giuseppe; Fogazzi, Giovanni B

    2016-06-01

    Urine microscopy is an important tool for the diagnosis and management of several conditions affecting the kidneys and urinary tract. In this review, we describe the automated instruments, based either on flow cytometry or digitized microscopy, that are currently in use in large clinical laboratories. These tools allow the examination of large numbers of samples in short periods. We also discuss manual urinary microscopy commonly performed by nephrologists, which we encourage. After discussing the advantages of phase contrast microscopy over bright field microscopy, we describe the advancements of urine microscopy in various clinical conditions. These include persistent isolated microscopic hematuria (which can be classified as glomerular or nonglomerular on the basis of urinary erythrocyte morphology), drug- and toxin-related cystalluria (which can be a clue for the diagnosis of acute kidney injury associated with intrarenal crystal precipitation), and some inherited conditions (eg, adenine phosphoribosyltransferase deficiency, which is associated with 2,8-dihydroxyadenine crystalluria, and Fabry disease, which is characterized by unique urinary lamellated fatty particles). Finally, we describe the utility of identifying "decoy cells" and atypical malignant cells, which can be easily done with phase contrast microscopy in unfixed samples. PMID:26806004

  6. 10 CFR 429.31 - Urinals.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Urinals. 429.31 Section 429.31 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.31 Urinals. (a) Sampling plan for selection of units for testing....

  7. 10 CFR 429.31 - Urinals.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Urinals. 429.31 Section 429.31 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.31 Urinals. (a) Sampling plan for selection of units for testing....

  8. 10 CFR 429.31 - Urinals.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Urinals. 429.31 Section 429.31 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.31 Urinals. (a) Sampling plan for selection of units for testing....

  9. Urine drug screen

    MedlinePlus

    Drug screen -- urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence indicates that you recently used these drugs. Some drugs may remain in your system for ...

  10. Leukocyte esterase urine test

    MedlinePlus

    ... the urine. This may mean you have a urinary tract infection . If this test is positive, the urine should ... Results Mean An abnormal result indicates a possible urinary tract infection. Alternative Names WBC esterase Images Male urinary system ...

  11. Urination - difficulty with flow

    MedlinePlus

    ... can take to care for yourself include: Keep track of your urination patterns and bring the report ... Medical Professional Call your provider if you notice urinary hesitancy, dribbling, or a weak urine stream. Call ...

  12. Uric acid urine test

    MedlinePlus

    The uric acid urine test measures the level of uric acid in urine. Uric acid level can also be checked using a blood ... help determine the cause of a high uric acid level in the blood. It may also be ...

  13. 24-hour urine protein

    MedlinePlus

    ... of fluid (dehydration) Any type of x-ray exam with dye (contrast material) within 3 days before the urine test Fluid from the vagina that gets into the urine Severe emotional stress Strenuous exercise Urinary tract infection

  14. Urine 24-hour volume

    MedlinePlus

    ... test results: Dehydration Any type of x-ray exam with dye (contrast material) within 3 days before the urine test Fluid from the vagina that gets into the urine Emotional stress Heavy exercise Urinary tract infection

  15. Urine concentration test

    MedlinePlus

    A urine concentration test measures the ability of the kidneys to conserve or excrete water. ... Increased urine concentration may be due to different conditions, such as: Heart failure Loss of body fluids (dehydration) from diarrhea or ...

  16. Urine drainage bags

    MedlinePlus

    ... catheter and urine drainage bag because you have urinary incontinence (leakage), urinary retention (not being able to urinate), ... wall repair Inflatable artificial sphincter Radical prostatectomy Stress urinary incontinence Urge incontinence Urinary incontinence Urinary incontinence - injectable implant ...

  17. Urine specific gravity test

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  18. Chemical measurement of urine volume

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.

    1978-01-01

    Chemical method of measuring volume of urine samples using lithium chloride dilution technique, does not interfere with analysis, is faster, and more accurate than standard volumetric of specific gravity/weight techniques. Adaptation of procedure to urinalysis could prove generally practical for hospital mineral balance and catechoamine determinations.

  19. Quantitative determination of nicotinic acid in micro liter volume of urine sample by drop-to-drop solvent microextraction coupled to matrix assisted laser desorption/ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Shrivas, Kamlesh; Patel, Devesh Kumar

    2011-01-01

    Drop-to-drop solvent microextraction (DDSME) coupled with matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) for quantitative determination of nicotinic acid in one drop of urine sample has been proposed. All parameters, such as type of organic solvent, extraction time, exposure volume solvent, pH of the sample solution that affecting the separation and preconcentration of nicotinic acid were investigated. Under the optimal conditions, the detection limit of the method was 20 ng mL -1 and the relative standard deviations (RSD) for determination of the nicotinic acid were in the range of 8.0-12.5%. The calculated calibration curves gave linearity in the range of 80-1000 ng mL -1. The main advantages of the proposed method are simple, fast, and small amount of sample solution is used for separation and preconcentration of nicotinic acid. This method could be also useful for the analysis of other interested analytes in small volume of biological samples, like plasma, saliva and urine, where the availability of samples are limited.

  20. Proton NMR-Based Metabolite Analyses of Archived Serial Paired Serum and Urine Samples from Myeloma Patients at Different Stages of Disease Activity Identifies Acetylcarnitine as a Novel Marker of Active Disease

    PubMed Central

    Khanim, Farhat L.; Günther, Ulrich L.; Viant, Mark R.; Morgan, Gareth J.; Bunce, Christopher M.; Drayson, Mark T.

    2013-01-01

    Background Biomarker identification is becoming increasingly important for the development of personalized or stratified therapies. Metabolomics yields biomarkers indicative of phenotype that can be used to characterize transitions between health and disease, disease progression and therapeutic responses. The desire to reproducibly detect ever greater numbers of metabolites at ever diminishing levels has naturally nurtured advances in best practice for sample procurement, storage and analysis. Reciprocally, since many of the available extensive clinical archives were established prior to the metabolomics era and were not processed in such an ‘ideal’ fashion, considerable scepticism has arisen as to their value for metabolomic analysis. Here we have challenged that paradigm. Methods We performed proton nuclear magnetic resonance spectroscopy-based metabolomics on blood serum and urine samples from 32 patients representative of a total cohort of 1970 multiple myeloma patients entered into the United Kingdom Medical Research Council Myeloma IX trial. Findings Using serial paired blood and urine samples we detected metabolite profiles that associated with diagnosis, post-treatment remission and disease progression. These studies identified carnitine and acetylcarnitine as novel potential biomarkers of active disease both at diagnosis and relapse and as a mediator of disease associated pathologies. Conclusions These findings show that samples conventionally processed and archived can provide useful metabolomic information that has important implications for understanding the biology of myeloma, discovering new therapies and identifying biomarkers potentially useful in deciding the choice and application of therapy. PMID:23431376

  1. A fast method for bisphenol A and six analogues (S, F, Z, P, AF, AP) determination in urine samples based on dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Rocha, Bruno Alves; da Costa, Bruno Ruiz Brandão; de Albuquerque, Nayara Cristina Perez; de Oliveira, Anderson Rodrigo Moraes; Souza, Juliana Maria Oliveira; Al-Tameemi, Maha; Campiglia, Andres Dobal; Barbosa, Fernando

    2016-07-01

    In this study, a novel method combining dispersive liquid-liquid microextraction (DLLME) and fast liquid chromatography coupled to mass spectrometry (LC-MS/MS) was developed and validated for the extraction and determination of bisphenol A (BPA) and six bisphenol analogues, namely bisphenol S (BPS), bisphenol F (BPF), bisphenol P (BPP), bisphenol Z (BPZ), bisphenol AP (BPAP) and bisphenol AF (BPAF) in human urine samples. Type and volume of extraction and disperser solvents, pH sample, ionic strength, and agitation were evaluated. The matrix-matched calibration curves of all analytes were linear with correlation coefficients higher than 0.99 in the range level of 0.5-20.0ngmL(-1). The relative standard deviation (RSD), precision, at three concentrations (1.0, 8.0 and 15.0ngmL(-1)) was lower than 15% with accuracy ranging from 90 to 112%. The biomonitoring capability of the new method was confirmed with the analysis of 50 human urine samples randomly collected from Brazilians. BPA was detected in 92% of the analyzed samples at concentrations ranging

  2. Urine pH test

    MedlinePlus

    A urine pH test measures the level of acid in urine. ... pH - urine ... meat products, or cheese can decrease your urine pH. ... to check for changes in your urine acid levels. It may be done to ... more effective when urine is acidic or non-acidic (alkaline).

  3. Purple Urine Bag Syndrome.

    PubMed

    Abubacker, Naufal Rizwan Taraganar; Jayaraman, Senthil Manikandan Thirumanilayur; R, Kannan; Sivanesan, Magesh Kumar; Mathew, Renu

    2015-08-01

    Purple urine bag syndrome (PUBS) is a rare disorder seen in elderly persons, wherein the urinary bag and the tubing turn in to purple colour. It is usually seen in patients who are on urinary catheters for a long time. Purple coloured urine occurs due to the accumulation of indigo and indirubin, which are the end products of tryptophan metabolism due to the action of sulfatases and phosphatases formed by bacteria like Providencia, Citrobacter, Enterobacter, Klebsiella etc. We present this interesting phenomenon of purple urine in a young male who was on prolonged urinary catheterization. The urine culture was positive for Providencia and constipation was an added risk factor for the purple urine. The urinary catheter and tubing was changed along with a course of antibiotics which lead to the normalization of the urine colour. PMID:26435987

  4. Quantitative immunological determination of 12 plasma proteins excreted in human urine collected before and after exercise

    PubMed Central

    Poortmans, Jacques; Jeanloz, Roger W.

    1968-01-01

    Urine was collected from 6 healthy male adults at rest and from 20 male adults after a marathon race (25 miles). The concentrated urines were quantitatively analyzed, by single radial immunodiffusion, for their content in 12 different plasma proteins: tryptophan-rich prealbumin, albumin, α1-acid glycoprotein, α1-antitrypsin, ceruloplasmin, haptoglobin, Gc-globulin, transferrin, hemopexin, β2-glycoprotein I, γA-globulin, and γG-globulin. Albumin, γA-globulin, and γG-globulin represent the major part of the plasma proteins detected in normal urine excreted by humans at rest (12, 0.5, and 2.5 mg respectively, out of a total excretion of 17.5 mg of plasma proteins per 24 hr). The other plasma proteins were excreted at a lower rate (< 0.4 mg/24 hr). The relative content of tryptophan-rich prealbumin, α1-antitrypsin, Gc-globulin, transferrin, and γG-globulin was lower in normal urine than in normal serum, whereas that of α1-acid glycoprotein, β2-glycoprotein I, and γA-globulin was higher. The ratio of γG-globulin to γA-globulin was 4.9:1. When plotted on a logarithmic scale, no direct relationship between the molecular weight of a protein and the value of its renal clearance could be observed. Strenuous exercise increased (up to 50-fold) the excretion of plasma proteins which represent 82% of the total proteins found in urine, instead of 57% in urine collected from humans at rest. There was particularly a significant rise of tryptophan-rich albumin, albumin, α1-acid glycoprotein, transferrin, γA-globulin, and γG-globulin (0.26, 127, 11.8, 3.3, 1.2, and 2.0 μg respectively, out of a total excretion of 167 μg of plasma proteins per min). The ratio of γG-globulin to γA-globulin was 16:1. After exercise, the renal clearance of proteins increased from 2 to 40 times, but, as for the urine of normal subjects at rest, no direct relationship between molecular weight and renal clearance could be observed. Images PMID:4170390

  5. 17-Ketosteroids urine test

    MedlinePlus

    ... Philadelphia, PA: Elsevier Saunders; 2014:chap 34. Chernecky CC, Berger BJ. Metyrapone (cortisol) - 24-hour urine. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . ...

  6. The Urinal Problem

    NASA Astrophysics Data System (ADS)

    Kranakis, Evangelos; Krizanc, Danny

    A man walks into a men's room and observes n empty urinals. Which urinal should he pick so as to maximize his chances of maintaining privacy, i.e., minimize the chance that someone will occupy a urinal beside him? In this paper, we attempt to answer this question under a variety of models for standard men's room behavior. Our results suggest that for the most part one should probably choose the urinal furthest from the door (with some interesting exceptions). We also suggest a number of variations on the problem that lead to many open problems.

  7. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate

  8. On-Demand Urine Analyzer

    NASA Technical Reports Server (NTRS)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  9. Fluorescent turn-on sensing of bacterial lipopolysaccharide in artificial urine sample with sensitivity down to nanomolar by tetraphenylethylene based aggregation induced emission molecule.

    PubMed

    Jiang, Guoyu; Wang, Jianguo; Yang, Yang; Zhang, Guanxin; Liu, Yaling; Lin, He; Zhang, Guilan; Li, Yongdong; Fan, Xiaolin

    2016-11-15

    A tetraphenylethylene based aggregation induced emission (AIE) probe, TPEPyE, bearing a positively charged pyridinium pendant was designed and synthesized. The positively charged TPEPyE can efficiently bind to the negatively charged lipopolysaccharide (LPS) through electrostatic interactions between the two oppositely charged species. As a result, upon the addition of LPS into the PBS solution of TPEPyE, this probe aggregated immediately onto the surface of LPS and resulted over 22-fold of fluorescence enhancement. TPEPyE exhibited good selectivity and high sensitivity toward LPS in PBS buffer solution and the detection limit was calculated to be 370 pM (3.7ng/mL). More notably, TPEPyE also retained good sensitivity and selectivity in artificial urine system (with much higher ionic strength) with the detection limit down to nanomolar. Moreover, this probe can also make a distinction between gram-positive bacteria Staphylococcus aureus (S. aureus) and gram-negative bacteria Escherichia coli (E. coli), making it a promising sensor for clinical monitoring of urinary tract infections. PMID:27155117

  10. Glucose urine test

    MedlinePlus

    ... with a color-sensitive pad. The color the dipstick changes to tells the provider the level of glucose in your urine. If needed, your provider may ask you to collect your urine at home over 24 hours . Your provider will tell you how to do ...

  11. Chemical Method of Urine Volume Measurement

    NASA Technical Reports Server (NTRS)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  12. Urine collection device

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females is described. It is comprised of a collection element defining a urine collection chamber and an inlet opening into the chamber and is adapted to be disposed in surrounding relation to the urethral opening of the user. A drainage conduit is connected to the collection element in communication with the chamber whereby the chamber and conduit together comprise a urine flow pathway for carrying urine generally away from the inlet. A first body of wicking material is mounted adjacent the collection element and extends at least partially into the flow pathway. The device preferably also comprise a vaginal insert element including a seal portion for preventing the entry of urine into the vagina.

  13. Rapid tests and urine sampling techniques for the diagnosis of urinary tract infection (UTI) in children under five years: a systematic review

    PubMed Central

    Whiting, Penny; Westwood, Marie; Watt, Ian; Cooper, Julie; Kleijnen, Jos

    2005-01-01

    Background Urinary tract infection (UTI) is one of the most common sources of infection in children under five. Prompt diagnosis and treatment is important to reduce the risk of renal scarring. Rapid, cost-effective, methods of UTI diagnosis are required as an alternative to culture. Methods We conducted a systematic review to determine the diagnostic accuracy of rapid tests for detecting UTI in children under five years of age. Results The evidence supports the use of dipstick positive for both leukocyte esterase and nitrite (pooled LR+ = 28.2, 95% CI: 17.3, 46.0) or microscopy positive for both pyuria and bacteriuria (pooled LR+ = 37.0, 95% CI: 11.0, 125.9) to rule in UTI. Similarly dipstick negative for both LE and nitrite (Pooled LR- = 0.20, 95% CI: 0.16, 0.26) or microscopy negative for both pyuria and bacteriuria (Pooled LR- = 0.11, 95% CI: 0.05, 0.23) can be used to rule out UTI. A test for glucose showed promise in potty-trained children. However, all studies were over 30 years old. Further evaluation of this test may be useful. Conclusion Dipstick negative for both LE and nitrite or microscopic analysis negative for both pyuria and bacteriuria of a clean voided urine, bag, or nappy/pad specimen may reasonably be used to rule out UTI. These patients can then reasonably be excluded from further investigation, without the need for confirmatory culture. Similarly, combinations of positive tests could be used to rule in UTI, and trigger further investigation. PMID:15811182

  14. The selection of female urinals: results of a multicentre evaluation.

    PubMed

    Fader, M; Pettersson, L; Dean, G; Brooks, R; Cottenden, A

    Female urinals are designed to enable women to empty their bladders while not on the toilet and are therefore potentially useful in preventing incontinence. However, there is little published information to guide product selection. Therefore, an evaluation of these products was undertaken by the Continence Products Evaluation Network (funded by the Medical Devices Agency). All 13 reusable female urinals available in the UK in March 1997 were evaluated. Each urinal was evaluated by 28-32 community-based women. Preliminarily, each subject tested all urinals by trying to place them in one or two of their preferred positions, to establish if the urinals were suitable for full testing. Each of the urinals that were selected for full testing were then used for 1 week each. During this week the subjects kept a diary to record leakage or spillage when using the urinal. At the end of the week a product evaluation form was filled in to record product performance. The results from full testing indicate that all urinals were successful for some subjects. However, some urinals were found to be successful for all four main positions (e.g. Petal Female Urinal) while others were successful mainly in one or two positions (e.g. Bridge Saddle Pan and Subaseal). Many urinals were successful in the standing/crouching and sitting on the edge (of chair or bed) positions, while comparatively few urinals were successful in the lying position. It was found that the chances of finding a suitable urinal increased with levels of independence. This means that subjects with higher levels of dependency found fewer urinals to be suitable for their needs when used without assistance. The results of this evaluation provide guidance for product selection. However, it is recommended that continence specialists keep samples of the full range of female urinals to enable women to experiment with urinals in order to find one that best suits their needs. PMID:10711014

  15. Estimation of the respiratory tract burden resulting from a prolonged inhalation exposure to aerosols of DU, based on the U in a 24-h urine sample taken years after exposure.

    PubMed

    Valdés, M

    2014-12-01

    A procedure is presented to estimate the respiratory tract burden from a prolonged inhalation exposure to particulate matter of depleted uranium, in cases where the rate of deposition is an unknown function. The precise range of possible values is identified. The calculations are based on the amount of depleted uranium measured in a single 24-h urine sample. In order to present an example, a simplified pharmacokinetical model is introduced. The results presented in this article are valid for any pharmacokinetical model represented by homogeneous linear differential equations with constant coefficients and non-zero initial values, and that clearly includes the International Commission on Radiological Protection model. In fact, they are applicable to any monitorable quantity measured over a short period of time, a monitorable quantity with a kinetic that can be described using a structurally similar system of differential equations to one describing these pharmacokinetical models. PMID:24682012

  16. Nonhazardous Urine Pretreatment Method

    NASA Technical Reports Server (NTRS)

    Akse, James R.; Holtsnider, John T.

    2012-01-01

    A method combines solid phase acidification with two non-toxic biocides to prevent ammonia volatilization and microbial proliferation. The safe, non-oxidizing biocide combination consists of a quaternary amine and a food preservative. This combination has exhibited excellent stabilization of both acidified and unacidified urine. During pretreatment tests, composite urine collected from donors was challenged with a microorganism known to proliferate in urine, and then was processed using the nonhazardous urine pre-treatment method. The challenge microorganisms included Escherichia coli, a common gram-negative bacteria; Enterococcus faecalis, a ureolytic gram-positive bacteria; Candida albicans, a yeast commonly found in urine; and Aspergillus niger, a problematic mold that resists urine pre-treatment. Urine processed in this manner remained microbially stable for over 57 days. Such effective urine stabilization was achieved using non-toxic, non-oxidizing biocides at higher pH (3.6 to 5.8) than previous methods in use or projected for use aboard the International Space Station (ISS). ISS urine pretreatment methods employ strong oxidants including ozone and hexavalent chromium (Cr(VI)), a carcinogenic material, under very acidic conditions (pH = 1.8 to 2.4). The method described here offers a much more benign chemical environment than previous pretreatment methods, and will lower equivalent system mass (ESM) by reducing containment volume and mass, system complexity, and crew time needed to handle pre-treatment chemicals. The biocides, being non-oxidizing, minimize the potential for chemical reactions with urine constituents to produce volatile, airborne contaminants such as cyanogen chloride. Additionally, the biocides are active under significantly less acidic conditions than those used in the current system, thereby reducing the degree of required acidification. A simple flow-through solid phase acidification (SPA) bed is employed to overcome the natural buffering

  17. Measurement of mercury in human urine.

    PubMed

    Goldberg, D M; Clarke, A D

    1970-03-01

    Four methods of determining the concentration of mercury in human urine have been studied. A simple method suitable for general laboratory use is recommended and the requirements for accurate results are defined. The method employs mild oxidation with permanganate and HS(2)O(4) followed by dithizone extraction and measurement of absorbance at 485 nm and 620 nm.No mercury was detected in any of 74 urines from unexposed laboratory controls and hospital patients. A random urine sample seems adequate for the investigation of clinical or industrial mercury poisoning. Two individuals, free of symptoms, but subjected to moderate exposure, excreted 3.0-9.7 mug of mercury per 100 ml of urine. After the administration of an organic mercurial to two volunteers, urinary excretion was rapid and virtually complete within 48 hours. PMID:5423951

  18. Protein electrophoresis - urine

    MedlinePlus

    ... nephropathy Kidney failure Multiple myeloma Nephrotic syndrome Acute urinary tract infection Risks There are no risks associated with this ... Primary amyloidosis Protein in diet Protein urine test Urinary tract infection - adults Update Date 5/29/2014 Updated by: ...

  19. Frequent or urgent urination

    MedlinePlus

    ... urinate. Causes Common causes of these symptoms are: Urinary tract infection (UTI) Enlarged prostate in middle-aged and older ... Urogynecology. Physiology of micturition, voiding dysfunction, urinary incontinence, urinary tract infections, and painful bladder syndrome. In: Lentz GM, Lobo ...

  20. Urine Tests (For Parents)

    MedlinePlus

    ... a doctor suspects that a child has a urinary tract infection (UTI) or a health problem that can cause ... to-Creatinine Ratio Kidney Diseases in Childhood Recurrent Urinary Tract Infections and Related Conditions Urinary Tract Infections Urine Test: ...

  1. Maple syrup urine disease

    MedlinePlus

    ... People with this condition cannot break down the amino acids leucine, isoleucine, and valine. This leads to a ... be done to check for this disorder: Plasma amino acid test Urine organic acid test Genetic testing There ...

  2. Urinating more at night

    MedlinePlus

    ... you to urinate more often during the night. Caffeine and alcohol after dinner can also lead to ... or urinary tract Drinking a lot of alcohol, caffeine, or other fluids before bedtime Enlarged prostate gland ( ...

  3. Citric acid urine test

    MedlinePlus

    ... used to diagnose renal tubular acidosis and evaluate kidney stone disease. ... tubular acidosis and a tendency to form calcium kidney stones. The following may decrease urine citric acid levels: ...

  4. PBG urine test

    MedlinePlus

    Porphobilinogen test ... temporarily stop taking medicines that may affect the test results. Be sure to tell your provider about ... This test involves only normal urination, and there is no discomfort.

  5. Leucine aminopeptidase - urine

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003617.htm Leucine aminopeptidase - urine To use the sharing features on this page, please enable JavaScript. Leucine aminopeptidase is a type of protein called an ...

  6. 24-hour urine protein

    MedlinePlus

    ... a blockage of blood vessels, or other causes Multiple myeloma Healthy people may have higher than normal urine ... Distal Hemolytic anemia Macroglobulinemia of Waldenstrom Microalbuminuria test Multiple myeloma Nephrotic syndrome Proximal Wilson disease Update Date 11/ ...

  7. USE OF DISPOSABLE DIAPERS TO COLLECT URINE IN EXPOSURE STUDIES

    EPA Science Inventory

    Large studies of children's health as it relates to exposures to chemicals in the environment often require measurements of biomarkers of chemical exposures or effects in urine samples. But collection of urine samples from infants and toddlers is difficult. For large exposure s...

  8. Achieving second order advantage with multi-way partial least squares and residual bi-linearization with total synchronous fluorescence data of monohydroxy-polycyclic aromatic hydrocarbons in urine samples.

    PubMed

    Calimag-Williams, Korina; Knobel, Gaston; Goicoechea, H C; Campiglia, A D

    2014-02-01

    An attractive approach to handle matrix interference in samples of unknown composition is to generate second- or higher-order data formats and process them with appropriate chemometric algorithms. Several strategies exist to generate high-order data in fluorescence spectroscopy, including wavelength time matrices, excitation-emission matrices and time-resolved excitation-emission matrices. This article tackles a different aspect of generating high-order fluorescence data as it focuses on total synchronous fluorescence spectroscopy. This approach refers to recording synchronous fluorescence spectra at various wavelength offsets. Analogous to the concept of an excitation-emission data format, total synchronous data arrays fit into the category of second-order data. The main difference between them is the non-bilinear behavior of synchronous fluorescence data. Synchronous spectral profiles change with the wavelength offset used for sample excitation. The work presented here reports the first application of total synchronous fluorescence spectroscopy to the analysis of monohydroxy-polycyclic aromatic hydrocarbons in urine samples of unknown composition. Matrix interference is appropriately handled by processing the data either with unfolded-partial least squares and multi-way partial least squares, both followed by residual bi-linearization. PMID:24456595

  9. Optimization of solvent bar microextraction combined with gas chromatography for preconcentration and determination of methadone in human urine and plasma samples.

    PubMed

    Ebrahimzadeh, Homeira; Mirbabaei, Fatemeh; Asgharinezhad, Ali Akbar; Shekari, Nafiseh; Mollazadeh, Narges

    2014-02-01

    In this study, solvent bar microextraction combined with gas chromatography-flame ionization detector (GC-FID) was used for preconcentration and determination of methadone in human body fluids. The target drug was extracted from an aqueous sample with pH 11.5 (source phase) into an organic extracting solvent (1-Undecanol) located inside the pores and lumen of a polypropylene hollow fiber as a receiving phase. To obtain high extraction efficiency, the effect of different variables on the extraction efficiency was studied using an experimental design. The variables of interest were the organic phase type, source phase pH, ionic strength, stirring rate, extraction time, concentration of Triton X-100, and extraction temperature, which were first investigated by Plackett-Burman design and subsequently by central composite design (CCD). So that the optimum experimental condition was obtained when the sodium chloride concentration was 5% (w/v); stirring rate, 700 rpm; extraction temperature, 20 °C; extraction time, 45 min and pH of the aqueous sample, 11.5. Under the optimized conditions, the preconcentration factors were between 275 and 300. The calibration curves were linear in the concentration range of 10-1500 μg L(-1). The limits of detection (LODs) were 2.7-7 and relative standard deviations (RSDs) of the proposed method were 5.9-7.3%. Ultimately, the applicability of the current method was evaluated by the extraction and determination of methadone in different biological samples. PMID:24412690

  10. [PMIM]Br@TiO2 nanocomposite reinforced hollow fiber solid/liquid phase microextraction: an effective extraction technique for measurement of benzodiazepines in hair, urine and wastewater samples combined with high-performance liquid chromatography.

    PubMed

    Es'haghi, Zarrin; Nezhadali, Azizollah; Bahar, Shahriyar; Bohlooli, Shahab; Banaei, Alireza

    2015-02-01

    A new design of hollow fiber solid-liquid phase microextraction (HF-SLPME) was developed for the determination of benzodiazepines (BZPs) in hair, urine and wastewater. The membrane extraction with 1-pentyl-3-methylimidazolium bromide coated titanium dioxide ([PMIM]Br@TiO2) sorbent used in this research is a two-phase supported membrane extraction consisting of an aqueous (donor phase), and n-octanol/nano [PMIM]Br@TiO2 (acceptor phase) system operated in direct immersion sampling mode. The 1-pentyl-3-methylimidazolium bromide (ionic liquid) coated nano TiO2 dispersed in the organic solvent (n-octanol) is held into a porous membrane supported by capillary forces and sonification. It is in contact with the feed phase, which is the aqueous sample. The experimental setup is very simple and highly affordable. The hollow fiber is disposable, so single use of the fiber reduces the risk of cross-contamination and carry-over problems. The proposed method allows the very effective and enriched recuperation of BZPs into one single extract. In order to obtain high extraction efficiency of the analytes using this novel sorbent, the main parameters were optimized. Under the optimized extraction conditions, the method showed good linearity (0.05-6000ngmL(-1)), low limits of detection (0.08-0.5ngmL(-1)) and good enrichment (533-1190). PMID:25589255

  11. ECLSS Sustaining Compatibility Testing on Urine Processor Assembly Nonmetallic Materials for Reformulation of Pretreated Urine Solution

    NASA Technical Reports Server (NTRS)

    Wingard, C. D.

    2015-01-01

    On International Space Station (ISS), the Urine Processor Assembly (UPA) converts human urine and flush water into potable water. The urine is acid-pretreated primarily to control microbial growth. In recent years, the sulfuric acid (H2SO4) pretreatment was believed to be largely responsible for producing salt crystals capable of plugging filters in UPA components and significantly reducing the percentage of water recovery from urine. In 2012, ISS management decided to change the acid pretreatment for urine from sulfuric to phosphoric with the goal of eliminating or minimizing formation of salt crystals. In 2013-2014, as part of the qualification of the phosphoric acid (H3PO4) formulation, samples of 12 nonmetallic materials used in UPA components were immersed for up to one year in pretreated urine and brine solutions made with the new H3PO4 formulation. Dynamic mechanical analysis (DMA) was used to measure modulus (stiffness) of the immersed samples compared to virgin control samples. Such compatibility data obtained by DMA for the H3PO4-based solutions were compared to DMA data obtained for the H2SO4-based solutions in 2002-2003.

  12. Urine Is Not Sterile: Use of Enhanced Urine Culture Techniques To Detect Resident Bacterial Flora in the Adult Female Bladder

    PubMed Central

    Hilt, Evann E.; McKinley, Kathleen; Pearce, Meghan M.; Rosenfeld, Amy B.; Zilliox, Michael J.; Mueller, Elizabeth R.; Brubaker, Linda; Gai, Xiaowu; Wolfe, Alan J.

    2014-01-01

    Our previous study showed that bacterial genomes can be identified using 16S rRNA sequencing in urine specimens of both symptomatic and asymptomatic patients who are culture negative according to standard urine culture protocols. In the present study, we used a modified culture protocol that included plating larger volumes of urine, incubation under varied atmospheric conditions, and prolonged incubation times to demonstrate that many of the organisms identified in urine by 16S rRNA gene sequencing are, in fact, cultivable using an expanded quantitative urine culture (EQUC) protocol. Sixty-five urine specimens (from 41 patients with overactive bladder and 24 controls) were examined using both the standard and EQUC culture techniques. Fifty-two of the 65 urine samples (80%) grew bacterial species using EQUC, while the majority of these (48/52 [92%]) were reported as no growth at 103 CFU/ml by the clinical microbiology laboratory using the standard urine culture protocol. Thirty-five different genera and 85 different species were identified by EQUC. The most prevalent genera isolated were Lactobacillus (15%), followed by Corynebacterium (14.2%), Streptococcus (11.9%), Actinomyces (6.9%), and Staphylococcus (6.9%). Other genera commonly isolated include Aerococcus, Gardnerella, Bifidobacterium, and Actinobaculum. Our current study demonstrates that urine contains communities of living bacteria that comprise a resident female urine microbiota. PMID:24371246

  13. DNA stability of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.

    PubMed

    Le Guern, Rémi; Miaux, Brigitte; Pischedda, Patricia; Herwegh, Stéphanie; Courcol, René

    2016-07-01

    We evaluated the DNA stability of Chlamydia trachomatis and Neisseria gonorrhoeae in 55 urine samples. Crossing threshold (Ct) values were highly similar after 3 to 14 days at room temperature (+0.002, P = 0.99). Consequently, it does not seem necessary to transfer urine specimens into a transport medium in less than 24 hours as recommended by manufacturers. PMID:27130478

  14. Blood in the Urine (Hematuria)

    MedlinePlus

    ... process starts in the kidneys , which remove excess fluids and waste from the blood and turn them into urine. The urine then flows through tubes called ureters into the bladder, where it's stored ...

  15. Environmental 24-hr Cycles Are Essential for Health.

    PubMed

    Lucassen, Eliane A; Coomans, Claudia P; van Putten, Maaike; de Kreij, Suzanne R; van Genugten, Jasper H L T; Sutorius, Robbert P M; de Rooij, Karien E; van der Velde, Martijn; Verhoeve, Sanne L; Smit, Jan W A; Löwik, Clemens W G M; Smits, Hermelijn H; Guigas, Bruno; Aartsma-Rus, Annemieke M; Meijer, Johanna H

    2016-07-25

    Circadian rhythms are deeply rooted in the biology of virtually all organisms. The pervasive use of artificial lighting in modern society disrupts circadian rhythms and can be detrimental to our health. To investigate the relationship between disrupting circadian rhythmicity and disease, we exposed mice to continuous light (LL) for 24 weeks and measured several major health parameters. Long-term neuronal recordings revealed that 24 weeks of LL reduced rhythmicity in the central circadian pacemaker of the suprachiasmatic nucleus (SCN) by 70%. Strikingly, LL exposure also reduced skeletal muscle function (forelimb grip strength, wire hanging duration, and grid hanging duration), caused trabecular bone deterioration, and induced a transient pro-inflammatory state. After the mice were returned to a standard light-dark cycle, the SCN neurons rapidly recovered their normal high-amplitude rhythm, and the aforementioned health parameters returned to normal. These findings strongly suggest that a disrupted circadian rhythm reversibly induces detrimental effects on multiple biological processes. PMID:27426518

  16. Cancer detection by native fluorescence of urine

    NASA Astrophysics Data System (ADS)

    Masilamani, Vadivel; Vijmasi, Trinka; Al Salhi, Mohammad; Govindaraj, Kanagaraj; Vijaya-Raghavan, Ayanam Parthasarathy; Antonisamy, Belavendra

    2010-09-01

    Because cancer is a dreaded disease, a number of techniques such as biomarker evaluation, mammograms, colposcopy, and computed tomography scan are currently employed for early diagnosis. Many of these are specific to a particular site, invasive, and often expensive. Hence, there is a definite need for a simple, generic, noninvasive protocol for cancer detection, comparable to blood and urine tests for diabetes. Our objective is to show the results of a novel study in the diagnosis of several cancer types from the native or intrinsic fluorescence of urine. We use fluorescence emission spectra (FES) and stokes shift spectra (SSS) to analyze the native fluorescence of the first voided urine samples of healthy controls (N=100) and those of cancer patients (N=50) of different etiology. We show that flavoproteins and porphyrins released into urine can act as generic biomarkers of cancer with a specificity of 92%, a sensitivity of 76%, and an overall accuracy of 86.7%. We employ FES and SSS for rapid and cost-effective quantification of certain intrinsic biomarkers in urine for screening and diagnosis of most common cancer types with an overall accuracy of 86.7%.

  17. Dipstick Spot urine pH does not accurately represent 24 hour urine PH measured by an electrode

    PubMed Central

    Omar, Mohamed; Sarkissian, Carl; Jianbo, Li; Calle, Juan; Monga, Manoj

    2016-01-01

    ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. Results A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Conclusions Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH. PMID:27286119

  18. Electrolytic pretreatment of urine

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  19. Ultrasonic-assisted magnetic solid phase extraction of morphine in urine samples by new imprinted polymer-supported on MWCNT-Fe3O4-NPs: Central composite design optimization.

    PubMed

    Kolaei, Milad; Dashtian, Kheibar; Rafiee, Zahra; Ghaedi, Mehrorang

    2016-11-01

    Multiwalled carbon nanotubes (MWCNTs) were magnetized with Fe3O4 nanoparticles (MWCNTs-Fe3O4-NPs) and subsequently coated by vinyl end groups (Vinyltrimethoxysilane). MWCNT-Fe3O4-NPs were used as support for a new morphine (MO) molecularly imprinted polymer (MWCNT-Fe3O4-NPs@MO-MIP) by surface imprinting polymerization method. The MWCNT-Fe3O4-NPs@MO-MIP was characterized by FTIR, VSM and SEM techniques and successfully used for determination of MO. Ultrasonic-assisted magnetic solid phase extraction followed by UV-vis spectrophotometer (UAMSPE-UV-vis) was investigated for MWCNT-Fe3O4-NPs@MO-MIP and compared with non-imprinted polymer (NIP) using batch method. Central composite design under response surface methodology was used for the evaluation of the effect of variables, individually, as well as their possible interaction effects on the adsorption process. The variables such as sonication time, MWCNT-Fe3O4-NPs@MO-MIP mass, initial concentration of MO and pH were investigated in this study. At optimum experimental conditions, UAMSPE-UV-vis method was exhibited a linear range of 0.8-8.7mgL(-1) of the MO concentration with a detection limit of 0.18mgL(-1). The relative standard deviation for the analyte was found to be lower than 2.32%. The MWCNT-Fe3O4-NPs@MO-MIP adsorption capacity was found to be 37.01mgg(-1). The enrichment and preconcentration factors were found to be 107.01 and 98.21, respectively. The developed method was finally applied successfully to the determination of MO in urine and wastewater samples with the recoveries ranged from 96.40 to 105.6%. PMID:27245975

  20. ABSENCE OF MUTAGENICITY IN THE URINE OF AUTOPSY SERVICE WORKERS EXPOSED TO FORMALDEHYDE: FACTORS INFLUENCING MUTAGENICITY TESTING OF URINE

    EPA Science Inventory

    The study examined the effect of exposure to autopsy workers to formaldehyde using urinary mutagenicity testing with Salmonella typhimurium. A matched control group was also studied. Additional studies including the recovery of histidine from urine samples, the determination of h...

  1. Application of electrolysis for detoxification of an antineoplastic in urine.

    PubMed

    Kobayashi, Toyohide; Hirose, Jun; Sano, Kouichi; Kato, Ryuji; Ijiri, Yoshio; Takiuchi, Hiroya; Tanaka, Kazuhiko; Goto, Emi; Tamai, Hiroshi; Nakano, Takashi

    2012-04-01

    Antineoplastics in excreta from patients have been considered to be one of the origins of cytotoxic, carcinogenic, teratogenic, and mutagenic contaminants in surface water. Recent studies have demonstrated that antineoplastics in clinical wastewater can be detoxified by electrolysis. In this study, to develop a method for the detoxification of antineoplastics in excreta, methotrexate solution in the presence of human urine was electrolyzed and evaluated. We found that urine inhibits detoxification by electrolysis; however, this inhibition decreased by diluting urine. In urine samples, the concentrations of active chlorine generated by anodic oxidation from 0.9% NaCl solution for inactivation of antineoplastics increased in dilution-dependent and time-dependent manner. These results indicate that electrolysis with platinum-based iridium oxide composite electrode is a possible method for the detoxification of a certain antineoplastic in urine. PMID:22154144

  2. Invited commentary: Quantifying salt in urine--a complex solution.

    PubMed

    de Boer, Ian H; Kestenbaum, Bryan

    2013-06-01

    Reduction of dietary sodium intake has been identified as a priority to reduce the worldwide burden of hypertension and cardiovascular disease. Dietary sodium intake is most precisely ascertained by using timed urine collection. Casual urine sodium measurements are relatively easy to perform, but their relationship to timed urine sodium measurements is unclear. In this issue of the Journal, Brown et al. (Am J Epidemiol. 2013;177(11):1180-1192) report the development and validation of equations to estimate 24-hour urine sodium excretion from casual urine samples. Their study included a large number of participants on 2 continents, a well-collected gold standard, separate discovery and validation samples, and relevant covariates. The resulting equations represent the best available methods to estimate dietary sodium intake from casual urine samples. However, the study is limited by evidence of a suboptimal model fit, restriction to people 20-59 years of age in North America and Europe, and exclusion and adjustment that further limit external validity. In addition, individual-level correlations of estimated and measured 24-hour urine sodium excretion were modest. Properly applied, the results will facilitate tracking of dietary sodium intake within populations over time and identification of communities for which dietary sodium restriction is most likely to be beneficial. Further work is needed to extend estimation to additional populations and improve individual-level assessment. PMID:23673248

  3. Challenges in urine bioanalytical assays: overcoming nonspecific binding.

    PubMed

    Ji, Allena Ji; Jiang, Zhiping; Livson, Yuliya; Davis, Jennifer Ann; Chu, Jasper Xuegong; Weng, Naidong

    2010-09-01

    Dr Allena Ji is the Director of Bioanalytical Services, XenoBiotic Laboratories, Inc., NJ, USA. She has worked in the bioanalytical field for many years and accumulated rich experience in LC-MS/MS method development, method validation and sample analysis under GLP compliance in large pharmaceutical company and contract laboratory settings. In the past 10 years, Allena worked at Pfizer (Legacy of Wyeth) and investigated many small-molecule drug candidates for their nonspecific binding in urine assays. Nonspecific binding of compounds results in a severe underestimation of the compounds' concentrations and poor precision and accuracy in urine bioanalytical assays. To overcome nonspecific binding in urine assays, Allena and her colleagues developed a series of practical approaches for urine method development. By adding an appropriate anti-adsorptive agent at its optimum concentration to the urine collection containers, the nonspecific binding can be blocked. Urine assays have much higher hurdles than plasma assays due to nonspecific binding and variability of urine pH, salt concentration, volume and solubility of drug(s) in urine. A simple and systematic approach for urine method development is emphasized in this paper. Nonspecific binding is a very serious issue in bioanalytical urine assays where a compound(s) adsorbs to the container wall. The adsorption happens frequently in urine assays because urine lacks proteins and lipids that can bind to the analytes or solubilize lipophilic analytes. Therefore, urine bioanalytical assays tend to suffer from analyte losses more often than plasma assays. In the past decade, there have been many methods described to overcome nonspecific adsorption in urine assays based on individual analyte characteristics. However, a common and simple method development approach for various analytes has not been discussed and summarized. In this article we demonstrate, discuss and summarize a common approach to urine method development with

  4. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Cibuzar, Branelle R.; Broyan, James Lee, Jr.

    2009-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  5. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriguez, Branelle R.; Broyan, James Lee, Jr.

    2008-01-01

    Exposure to microgravity during human spaceflight is required to be defined and understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Urine voids are capable of measuring the calcium and other metabolic byproducts in a constituent s urine. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross contamination (<0.7 ml urine) and has volume accuracy of +/-2% between 100 to 1000 ml urine voids.

  6. Detection of chrysotile asbestos in workers urine

    SciTech Connect

    Finn, M.B.; Hallenbeck, W.H.

    1985-03-01

    Urinary asbestos concentrations were evaluated as an indicator of occupational exposure to chrysotile asbestos via inhalation and ingestion. Detection of asbestos in the urine represents the first step in developing a biological indicator of exposure. Such an indicator could be used to supplement exposure data from workplace air sampling. A biological indicator would be particularly valuable in evaluating workers with intermittent airborne asbestos exposures and in determining if airborne exposure results in penetration of asbestos through the lung or gastro-intestinal tract. Transmission electron microscopy was selected as the most sensitive technique for identification of all sizes of asbestos fibers which might appear in the urine. The levels of chrysotile asbestos detected in the urine of five workers were significantly greater than the asbestos concentrations in matched field blanks. Also, the workers urinary asbestos levels were significantly greater than the concentrations found in the control group. Finally, the levels of chrysotile asbestos detected in the urine of two of six controls were significantly greater than those in matched field blanks. Although the project was not specifically designed to correlate urinary and airborne asbestos concentrations, preliminary data indicated that a correlation did not exist between these factors.

  7. Voltammetric studies on the potent carcinogen, 7,12-dimethylbenz[a]anthracene: Adsorptive stripping voltammetric determination in bulk aqueous forms and human urine samples and detection of DNA interaction on pencil graphite electrode.

    PubMed

    Yardim, Y; Keskin, E; Levent, A; Ozsöz, M; Sentürk, Z

    2010-01-15

    7,12-Dimethylbenz[a]anthracene (DMBA), is a widely studied polycyclic aromatic hydrocarbon that has long been recognized as a very potent carcinogen. Initially, the electrochemical oxidation of DMBA at the glassy carbon and pencil graphite electrodes in non-aqueous media (dimethylsulphoxide with lithium perchlorate) was studied by cyclic voltammetry. DMBA was irreversibly oxidized in two steps at high positive potentials, resulting in the ill-resolved formation of a couple with a reduction and re-oxidation wave at much lower potentials. Special attention was given to the use of adsorptive stripping voltammetry together with a medium exchange procedure on disposable pencil graphite electrode in aqueous solutions over the pH range of 3.0-9.0. The response was characterized with respect to pH of the supporting electrolyte, pre-concentration time and accumulation potential. Using square-wave stripping mode, the compound yielded a well-defined voltammetric response in acetate buffer, pH 4.8 at +1.15V (vs. Ag/AgCl) (a pre-concentration step being carried out at a fixed potential of +0.60V for 360s). The process could be used to determine DMBA concentrations in the range 2-10nM, with an extremely low detection limit of 0.194nM (49.7ngL(-1)). The applicability to assay of spiked human urine samples was also illustrated. Finally, the interaction of DMBA with fish sperm double-stranded DNA based on decreasing of the oxidation signal of adenine base was studied electrochemically by using differential pulse voltammetry with a pencil graphite electrode at the surface and also in solution. The favorable signal-to-noise characteristics of biosensor resulted in low detection limit (ca. 46nM) following a 300-s interaction. These results displayed that the electrochemical DNA-based biosensor could be used for the sensitive, rapid, simple and cost effective detection of DMBA-DNA interaction. PMID:20006098

  8. Some historical aspects of urinals and urine receptacles.

    PubMed

    Mattelaer, J J

    1999-06-01

    In the history of mankind the first receptacles for urine were made and employed for diagnostic purposes and developed over centuries to a sophisticated matula. In ancient Greek and Roman history, chamber pots existed and urine was collected to bleach sheets, but it was only in the late medieval and renaissance times that a real urine receptacle or urinal for daily use was developed. We give a short description of the materials used, including clay, pewter, copper, and silver, but more sophisticated receptacles made of china, such as the bourdaloue, and of glass, such as the Kuttrolf, were also developed for use during long church ceremonies. Less known are the wooden "pipes" from Turkestan, used to keep babies dry. In the long history of mankind, urinals sometimes became very original objects. PMID:10418087

  9. Chemical enhancement of footwear impressions in urine on fabric.

    PubMed

    Farrugia, Kevin J; Bandey, Helen; Bleay, Steve; NicDaéid, Niamh

    2012-01-10

    A range of chemical techniques were utilised for the enhancement of footwear impressions deposited on a variety of fabric types of different colours with urine as a contaminant. A semi-automated stamping device was used to deliver test impressions at a set force to minimise the variability between impressions; multiple impressions were produced and enhanced by each reagent to determine the repeatability of the enhancement. Urine samples from different donors were analysed using a spectrofluorophotometer revealing differences between individuals. Results indicated that the enhancement of footwear impressions in urine was possible using amino acid staining techniques whereas protein stains failed to achieve successful enhancement. PMID:21813253

  10. Chemical composition of rainbow trout urine following acute hypoxic stress

    USGS Publications Warehouse

    Hunn, Joseph B.

    1969-01-01

    Rainbow trout (Salmo gairdnerii) were anesthetized with MS-222, catheterized, and introduced into urine collecting chambers. Twenty-four hours after introduction, a 4-hour accumulation of urine was collected to serve as the control. Water flow to the chambers was then discontinued for 30 minutes during which the oxygen content of the water exiting in the chamber dropped from 4.9 to 2.8 mg/l. Following this hypoxic stress fresh water was restored and accumulated urine samples were taken for analysis at 1, 4, and 20 hours post-hypoxic stress. Rainbow trout excrete abnormally high concentrations of Na, K, Mg, Cl, and inorganic PO4 following hypoxia.

  11. Hematuria (Blood in the Urine)

    MedlinePlus

    ... tract is the body’s drainage system for removing wastes and extra water. The urinary tract includes two kidneys, two ureters, ... 1 to 2 quarts of urine, composed of wastes and extra water. The urine flows from the kidneys to the ...

  12. Mining the human urine proteome for monitoring renal transplant injury.

    PubMed

    Sigdel, Tara K; Gao, Yuqian; He, Jintang; Wang, Anyou; Nicora, Carrie D; Fillmore, Thomas L; Shi, Tujin; Webb-Robertson, Bobbie-Jo; Smith, Richard D; Qian, Wei-Jun; Salvatierra, Oscar; Camp, David G; Sarwal, Minnie M

    2016-06-01

    The human urinary proteome provides an assessment of kidney injury with specific biomarkers for different kidney injury phenotypes. In an effort to fully map and decipher changes in the urine proteome and peptidome after kidney transplantation, renal allograft biopsy matched urine samples were collected from 396 kidney transplant recipients. Centralized and blinded histology data from paired graft biopsies was used to classify urine samples into diagnostic categories of acute rejection, chronic allograft nephropathy, BK virus nephritis, and stable graft. A total of 245 urine samples were analyzed by liquid chromatography-mass spectrometry using isobaric Tags for Relative and Absolute Quantitation (iTRAQ) reagents. From a group of over 900 proteins identified in transplant injury, a set of 131 peptides were assessed by selected reaction monitoring for their significance in accurately segregating organ injury causation and pathology in an independent cohort of 151 urine samples. Ultimately, a minimal set of 35 proteins were identified for their ability to segregate the 3 major transplant injury clinical groups, comprising the final panel of 11 urinary peptides for acute rejection (93% area under the curve [AUC]), 12 urinary peptides for chronic allograft nephropathy (99% AUC), and 12 urinary peptides for BK virus nephritis (83% AUC). Thus, urinary proteome discovery and targeted validation can identify urine protein panels for rapid and noninvasive differentiation of different causes of kidney transplant injury, without the requirement of an invasive biopsy. PMID:27165815

  13. Fiber loop ringdown glucose sensors: initial tests in human diabetic urines

    NASA Astrophysics Data System (ADS)

    Kaya, Malik; Wang, Chuji

    2014-06-01

    Fiber loop ringdown technique has shown promise in biomedical applications in recent studies. In the present work, fiber loop ringdown sensors using the evanescent field as the sensing mechanism have been fabricated and tested in actual human urines for the first time. In order to evaluate the sensors' performance, the sensors were comparatively tested in healthy human urines, synthetic urine solutions, and diabetic urines. Due to different features or chemical compositions of each urine sample, the sensors experience different optical losses, equivalently, different ringdown times. The comparative results show that evanescent field-fiber loop ringdown glucose sensors can discriminate the three different urine samples by displaying different ringdown times. The evanescent field-fiber loop ringdown glucose sensors had fast response, good reproducibility, and high sensitivity. The promising results imply that the evanescent field-fiber loop ringdown sensors have potential for near real-time detection of diabetic urines.

  14. Microanalyzer for Biomonitoring of Lead (Pb) in Blood and Urine

    SciTech Connect

    Yantasee, Wassana; Timchalk, Chuck; Lin, Yuehe

    2007-01-01

    Biomonitoring of lead (Pb) in blood and urine enables quantitative evaluation of human occupational and environmental exposures to Pb. The state-of-the-art ICP-MS instruments analyze metals in laboratories, resulting in lengthy turn around time, and are expensive. In response to the growing need for metal analyzer for on-site, real-time monitoring of trace metals in individuals, we developed a portable microanalyzer based on flow-injection/adsorptive stripping voltammetry and used it to analyze Pb in rat blood and urine. Fouling of electrodes by proteins often prevents the effective use of electrochemical sensors in biological matrices. Minimization of such fouling was accomplished with the suitable sample pretreatment and the turbulent flowing of Pb contained blood and urine onto the glassy electrode inside the microanalyzer, which resulted in no apparent electrode fouling even when the samples contained 50% urine or 10% blood by volume. There was no matrix effect on the voltammetric Pb signals even when the samples contained 10% blood or 10% urine. The microanalyzer offered linear concentration range relevant to Pb exposure levels in human (0-20 ppb in 10%-blood samples, 0-50 ppb in 50%-urine samples). The device had excellent sensitivity and reproducibility; Pb detection limits were 0.54 ppb and 0.42 ppb, and % RSDs were 4.9 and 2.4 in 50%-urine and 10%-blood samples, respectively. It offered a high throughput (3 min per sample) and had economical use of samples (60 ?L per measurement), making the collection of blood being less invasive especially to children, and had low reagent consumption (1 ?g of Hg per measurement), thus minimizing the health concerns of mercury use. Being miniaturized in size, the microanalyzer is portable and field-deployable. Thus, it has a great potential to be the next-generation analyzer for biomonitoring of toxic metals.

  15. Optimizing Urine Processing Protocols for Protein and Metabolite Detection

    PubMed Central

    Siddiqui, Nazema Y; DuBois, Laura G; St John-Williams, Lisa; Will, Thompson J; Grenier, Carole; Burke, Emily; Fraser, Matthew O; Amundsen, Cindy L; Murphy, Susan K

    2016-01-01

    Background In urine, factors such as timing of voids, and duration at room temperature (RT) may affect the quality of recovered protein and metabolite data. Additives may aid with detection, but can add more complexity in sample collection or analysis. We aimed to identify the optimal urine processing protocol for clinically-obtained urine samples that allows for the highest protein and metabolite yields with minimal degradation. Methods Healthy women provided multiple urine samples during the same day. Women collected their first morning (1st AM) void and another “random void”. Random voids were aliquotted with: 1) no additive; 2) boric acid (BA); 3) protease inhibitor (PI); or 4) both BA + PI. Of these aliquots, some were immediately stored at 4°C, and some were left at RT for 4 hours. Proteins and individual metabolites were quantified, normalized to creatinine concentrations, and compared across processing conditions. Sample pools corresponding to each processing condition were analyzed using mass spectrometry to assess protein degradation. Results Ten Caucasian women between 35-65 years of age provided paired 1st morning and random voided urine samples. Normalized protein concentrations were slightly higher in 1st AM compared to random “spot” voids. The addition of BA did not significantly change proteins, while PI significantly improved normalized protein concentrations, regardless of whether samples were immediately cooled or left at RT for 4 hours. In pooled samples, there were minimal differences in protein degradation under the various conditions we tested. In metabolite analyses, there were significant differences in individual amino acids based on the timing of the void. Conclusions For comparative translational research using urine, information about void timing should be collected and standardized. For urine samples processed in the same day, BA does not appear to be necessary while the addition of PI enhances protein yields, regardless of 4

  16. The effects of urine concentration, and cushion centrifugation to remove urine, on the quality of cool-stored stallion sperm.

    PubMed

    Voge, Jared; Varner, Dickson D; Blanchard, Terry L; Meschini, Marika; Turner, Carly; Teague, Sheila R; Brinsko, Steven P; Love, Charles C

    2016-09-15

    Urine-contaminated stallion semen is a clinical problem due to a variety of causes. The effect of the level of urine contamination on the longevity of sperm quality has not been evaluated. The aim of this study was to determine the effects of urine concentration level (0%, 10%, 20%, 30%, and 40%) and cushioned centrifugation and resuspension of the sperm pellet in fresh extender, on measures of sperm quality, immediately after semen collection (T0), after 1 hour of storage at room temperature (T1), and after 24 hours of cooled storage (T24). In general, most sperm quality measures declined with increasing urine concentration starting at T0. Cushioned centrifugation (CC), but not simple dilution, generally maintained sperm quality at T24 as compared with T1. At T24, total sperm motility was higher in all urine-contaminated CC samples compared with uncentrifuged samples (P < 0.05); sperm viability was lower in CC than uncentrifuged at a urine concentration of 20%, but higher at 30% and 40% (P < 0.05); and DNA quality was decreased (higher % cells outside the main population) in all urine concentrations (P < 0.05). Immediate extension in semen extender, followed by cushioned centrifugation and resuspension of the sperm pellet in fresh extender, provided the best option for preserving sperm quality of urospermic semen. PMID:27349135

  17. Pure human urine is a good fertiliser for cucumbers.

    PubMed

    Heinonen-Tanski, Helvi; Sjöblom, Annalena; Fabritius, Helena; Karinen, Päivi

    2007-01-01

    Human urine obtained from separating toilets was tested as a fertiliser for cultivation of outdoor cucumber (Cucumis sativus L.) in a Nordic climate. The urine used contained high amounts of nitrogen with some phosphorus and potassium, but numbers of enteric microorganisms were low even though urine had not been preserved before sampling. The cucumber yield after urine fertilisation was similar or slightly better than the yield obtained from control rows fertilised with commercial mineral fertiliser. None of the cucumbers contained any enteric microorganisms (coliforms, enterococci, coliphages and clostridia). In the taste assessment, 11 out of 20 persons could recognise which cucumber of three cucumbers was different but they did not prefer one over the other cucumber samples, since all of them were assessed as equally good. PMID:16413181

  18. NHEXAS PHASE I ARIZONA STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 6 metals in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. The sample consists of the fir...

  19. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Urine data set contains analytical results for measurements of up to 7 metals in 86 urine samples over 86 households. Each sample was collected from the primary respondent within each household. The sample consists of the first morning void following the 24-hour d...

  20. 24-HOUR DIFFUSIVE SAMPLING OF 1,3-BUTADIENE IN AIR ONTO CARBOPACK X SOLID ADSORBENT FOLLOWED BY THERMAL DESORPTION/GC/MS ANALYSIS - FEASIBILITY STUDY

    EPA Science Inventory

    Diffusive sampling of 1,3-butadiene for 24 hr onto the graphitic adsorbent Carbopack X packed in a stainless steel tube badge (6.3 mm o.d., 5 mm i.d., and 90 mm in length) with analysis by thermal desorption/gas chromatography (GC)/mass spectrometry (MS) has been evaluated in con...

  1. Silver nanoparticle assisted urine sugar determination using thermal lens spectroscopy

    NASA Astrophysics Data System (ADS)

    Thomas, Lincy; John, Jisha; George, Nibu A.; Kurian, Achamma

    2014-11-01

    Nanotechnology plays a vital role in the development of biosensors by enhancing their sensitivity and performance. In this paper, we report a novel urine sugar sensing method that makes use of the unique properties of silver-nanofluids in combination with the laser induced photothermal lens technique. The thermal lens signal decreases with increase in sugar levels in urine samples, which may be attributed to the enhanced interaction of glucose and conduction electrons of silver-nanoparticles, thereby changing the surface plasmon energy.

  2. Homogentisic acid interference in routine urine creatinine determination.

    PubMed

    Loken, Perry R; Magera, Mark J; Introne, Wendy; Tortorelli, Silvia; Gavrilov, Dimitar; Oglesbee, Devin; Rinaldo, Piero; Matern, Dietrich; Raymond, Kimiyo

    2010-05-01

    We report the artifactual elevation of homogentisic acid (HGA) in urine from alkaptonuric patients after replacing the creatinine method (Jaffe reaction) in our laboratory with an automated enzymatic method. Samples with elevated HGA by GC-MS had lower creatinine values as determined by the enzymatic method than by the Jaffe reaction. The low creatinine values were due to interference by HGA in the enzymatic method. The enzymatic method is unsuitable for creatinine determination in urine of patients with alkaptonuria. PMID:20138792

  3. Determination of Strontium-90 in urine by extraction without ashing

    SciTech Connect

    Scasnar, V.

    1984-03-01

    Urine is a complex matrix. Any analytical separation that attempts to isolate an almost insignificant mass of material from urine must be capable of overcoming the high variability of sample composition. The urine is usually ashed to destroy all organic constituents to reduce the complexity of the sample. This step is time- and labor-consuming. In the method proposed no ashing of urine sample is necessary. Accordingly, radiostrontium can be directly extracted from urine after cesium has been extracted, when a proper amount of PEG 300 is added. This paper demonstrates that PEG strongly increases the extraction of microamounts of strontium into nitrobenzene, when the univalent hydrophobic anion of dicarbolide-H/sup +/ was used. The magnitude of the synergistic effect > 10/sup 3/ creates good conditions for the extraction of strontium after previous extraction of cesium. Since both radionuclides are most significant components of fission mixture and the extraction of other fission and activated radionuclides using dicarbolide-H/sup +/ appears to be low, the conditions for a selective and quantitative separation of radiostrontium from contaminated urine were investigated in this work. Dicarbolide-H/sup +/ with high stability constant of its complex anion, fully dissociated and stable also in a high acidic media, together with PEG of mean relative molecular mass 300 was used for this purpose.

  4. Development of a Targeted Urine Proteome Assay for Kidney Diseases

    PubMed Central

    Cantley, Lloyd G.; Colangelo, Christopher M.; Stone, Kathryn L.; Chung, Lisa; Belcher, Justin; Abbott, Thomas; Cantley, Jennifer L.; Williams, Kenneth R.; Parikh, Chirag R.

    2016-01-01

    Human urine is the least invasive and most readily available bio fluid whose proteome has been shown to change in response to disease or drug treatment. Urine is thus very amenable to quantitative proteomics and is a logical sample choice for identifying protein biomarkers for kidney diseases. In this study potential biomarkers were identified initially by using a multi-proteomics workflow to compare urine proteomes of kidney transplant patients who exhibited immediate versus delayed graft function. To comprehensively interrogate the urine proteome two “bottom up”, mass spectrometric-based discovery approaches, iTRAQ and Label Free Quantitation (LFQ), were complemented by Differential Fluorescence Gel Electrophoresis (DIGE) analyses of intact urine proteins from kidney transplant recipients who received a deceased donor kidney. Differentially expressed proteins in the two patient groups were identified, and corresponding stable isotope–labeled internal peptide standard (SIS) peptides were synthesized for scheduled multiple reaction monitoring (MRM). The Targeted Urine Proteome Assay (TUPA) was then developed by identifying those peptides for which there were at least 2 transitions for which interference in a urine matrix across 156 MRM runs was less than 30%. This resulted in a final assay that monitors 224 peptides corresponding to 167 quantifiable proteins. PMID:26220717

  5. [Pastel in the urine bag].

    PubMed

    Cantaloube, Lucie; Lebaudy, Cécile; Hermabessière, Sophie; Rolland, Yves

    2012-03-01

    Purple urine bag syndrome is a relatively unknown phenomenon in which the urine bag and the collector of chronically catheterized patients turn purple or blue. It affects predominantly women, and is mainly reported in elderly patients. The mechanism seems to be related to the appearance in the urine of two compounds that have been identified as indigo (blue) and indirubin (red) which bind to the urine bag and the collector. Several associated factors are usually mentioned such as constipation, alkaline urine, bed rest, institutionalization or cognitive impairment. They are risk factor of this phenomenon. On the other hand, an infection or a urinary bacterial colonization is necessary and high bacterial counts seem to be the critical step in the development of the purple urine bag syndrome. We report on two cases of purple urine bag syndrome observed in two patients being treated in a long-term care unit. Both of whom were diagnosed with indwelling urinary bacterial colonization, with Escherichia coli and Pseudomonas aeruginosa respectively. PMID:22414392

  6. Toenail, Blood and Urine as Biomarkers of Manganese Exposure

    PubMed Central

    Laohaudomchok, Wisanti; Lin, Xihong; Herrick, Robert F.; Fang, Shona C.; Cavallari, Jennifer M.; Christiani, David C.; Weisskopf, Marc G.

    2011-01-01

    Objective This study examined the correlation between manganese exposure and manganese concentrations in different biomarkers. Methods Air measurement data and work histories were used to determine manganese exposure over a workshift and cumulative exposure. Toenail samples (n=49), as well as blood and urine before (n=27) and after (urine, n=26; blood, n=24) a workshift were collected. Results Toenail manganese, adjusted for age and dietary manganese, was significantly correlated with cumulative exposure in months 7-9, 10-12, and 7-12 before toenail clipping date, but not months 1-6. Manganese exposure over a work shift was not correlated with changes in blood nor urine manganese. Conclusions Toenails appeared to be a valid measure of cumulative manganese exposure 7 to 12 months earlier. Neither change in blood nor urine manganese appeared to be suitable indicators of exposure over a typical workshift. PMID:21494156

  7. Urine collection apparatus. [feminine hygiene

    NASA Technical Reports Server (NTRS)

    Michaud, R. B. (Inventor)

    1981-01-01

    A urine collection device for females comprises an interface body with an interface surface for engagement with the user's body. The interface body comprises a forward portion defining a urine-receiving bore which has an inlet in the interface surface adapted to be disposed in surrounding relation to the urethral opening of the user. The interface body also has a rear portion integrally adjoining the forward portion and a non-invasive vaginal seal on the interface surface for sealing the vagina of the user from communication with the urine-receiving bore. An absorbent pad is removably supported on the interface body and extends laterally therefrom. A garment for supporting the urine collection is also disclosed.

  8. Treating urine by Spirulina platensis

    NASA Astrophysics Data System (ADS)

    Yang, Chenliang; Liu, Hong; Li, Ming; Yu, Chengying; Yu, Gurevich

    In this paper Spirulina platensis with relatively high nutrition was cultivated to treat human urine. Batch culture showed that the consumption of N in human urine could reach to 99%, and the consumption of P was more than 99.9%, and 1.05 g biomass was obtained by treating 12.5 ml synthetic human urine; continuous culture showed that S. platensis could consume N, Cl, K and S in human urine effectively, and the consumption could reach to 99.9%, 75.0%, 83.7% and 96.0%, respectively, and the consumption of P was over 99.9%, which is very important to increase the closure and safety of the bioregenerative life support system (BLSS).

  9. An emergency bioassay method for (210)Po in urine.

    PubMed

    Guérin, Nicolas; Dai, Xiongxin

    2015-09-01

    A rapid method was developed to efficiently measure (210)Po in urine samples in an emergency situation. Polonium-210 in small urine samples (10 mL) was spontaneously deposited on a stainless steel disc in 1 M HCl at room temperature for 4 h in a polyethylene bottle. The metallic disc was then counted for 4 h by alpha spectrometry. The developed method allowed the preparation of large sample batch in a short time. The method meets the requirements for an emergency bioassay procedure. PMID:26115206

  10. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  11. Uncertainties of Mayak urine data

    SciTech Connect

    Miller, Guthrie; Vostrotin, Vadim; Vvdensky, Vladimir

    2008-01-01

    For internal dose calculations for the Mayak worker epidemiological study, quantitative estimates of uncertainty of the urine measurements are necessary. Some of the data consist of measurements of 24h urine excretion on successive days (e.g. 3 or 4 days). In a recent publication, dose calculations were done where the uncertainty of the urine measurements was estimated starting from the statistical standard deviation of these replicate mesurements. This approach is straightforward and accurate when the number of replicate measurements is large, however, a Monte Carlo study showed it to be problematic for the actual number of replicate measurements (median from 3 to 4). Also, it is sometimes important to characterize the uncertainty of a single urine measurement. Therefore this alternate method has been developed. A method of parameterizing the uncertainty of Mayak urine bioassay measmements is described. The Poisson lognormal model is assumed and data from 63 cases (1099 urine measurements in all) are used to empirically determine the lognormal normalization uncertainty, given the measurement uncertainties obtained from count quantities. The natural logarithm of the geometric standard deviation of the normalization uncertainty is found to be in the range 0.31 to 0.35 including a measurement component estimated to be 0.2.

  12. Comparison of Urine and Oral Fluid for Workplace Drug Testing

    PubMed Central

    Casolin, Armand

    2016-01-01

    Aims To determine the relative detection rates of urine versus oral fluid testing in a safety sensitive industry and the correlation with diagnosed substance use disorders and possible impairment at work. Methods The trial involved 1,500 paired urine and oral fluid tests performed in accordance with Australian Standard/New Zealand Standard (AS/NZS) 4308:2008 and AS 4760:2006. Workers who returned a positive test were screened for substance use disorders, as defined by DSM-5, and for possible impairment at work following that particular episode of substance use. Results Substances were detected in 3.7% (n = 56) of urine samples and 0.5% (n = 8) of oral fluid samples (p < 0.0001). One worker (0.07%) had a substance detected on oral fluid alone versus 49 workers (3.3%) who had substances detected on urine alone. Twelve workers returned a positive result, defined as being consistent with the use of an illicit drug or a controlled substance without a clinical indication and prescription. Nine workers tested positive on urine alone, one on oral fluid alone and two on both (p = 0.0114). Of note, 6/11 workers who tested positive on urine had possible impairment at work and 2/11 had a substance use disorder versus 2/3 and 0/3, respectively, who tested positive on oral fluid. Conclusions Urine drug testing performed in accordance with AS/NZS 4308:2008 is more likely to detect overall substance use and illicit drug use than oral fluid testing conducted in accordance with AS 4760:2006. Urine testing performed in accordance with AS/NZS 4308:2008 may also be more likely to detect workers with possible impairment at work and substance use disorders than oral fluid testing performed in accordance with AS 4760:2006. PMID:27344042

  13. NHEXAS PHASE I ARIZONA STUDY--PESTICIDE METABOLITES IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticide Metabolites in Urine data set contains analytical results for measurements of up to 4 pesticide metabolites in 176 urine samples over 176 households. Each sample was collected from the primary respondent within each household during Stage III of the NHEXAS study. ...

  14. NHEXAS PHASE I REGION 5 STUDY--METALS IN URINE ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 600 urine samples. For some chemicals, particularly arsenic, urine provides the best information about the relationship between exposure and body burden. Two samples were collected from each participant on da...

  15. Psychopathology and Urine Toxicology in Methadone Patients

    PubMed Central

    Sadek, Gamal; Cernovsky, Zack; Chiu, Simon

    2015-01-01

    Several studies reported high rates of psychiatric commorbidity among methadone patients. We examined the relationships of measures of psychopathology to outcomes of screening urine tests for cocaine, opiates, and benzodiazepines in a sample of 56 methadone patients. They also completed the Symptom Check List-90-Revised (SCL-90-R). The highest scales in the SCL-90-R profile of our patients were those indicating somatic discomfort, anger, phobic anxiety, paranoid ideation, and also obsessive-compulsive disorder symptoms (scores above the 39th percentile). The only significant correlations between urine tests and SCL-90-R psychopathology were those involving benzodiazepines: patients with urine tests positive for benzodiazepines had lower social self-confidence (r=0.48), were more obsessive-compulsive (r=0.44), reported a higher level of anger (r=0.41), of phobic tendencies (r=40), of anxiety (r=0.39), and of paranoid tendencies (r=0.38), and also reported more frequent psychotic symptoms (r=0.43). PMID:26266026

  16. Measurement of Menadione in Urine by HPLC

    PubMed Central

    Rajabi, Ala Al; Peterson, James; Choi, Sang Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-01-01

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C30 column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H2O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R2) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3 pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Research support: USDA ARS Cooperative Agreement 58-1950-7-707. PMID:20719580

  17. A Comprehensive Investigation toward the Indicative Proteins of Bladder Cancer in Urine: From Surveying Cell Secretomes to Verifying Urine Proteins.

    PubMed

    Guo, Jiao; Ren, Yan; Hou, Guixue; Wen, Bo; Xian, Feng; Chen, Zhen; Cui, Ping; Xie, Yingying; Zi, Jin; Lin, Liang; Wu, Song; Li, Zesong; Wu, Lin; Lou, Xiaomin; Liu, Siqi

    2016-07-01

    Urine is an ideal material to study the cancer-related protein biomarkers in bladder, whereas exploration to these candidates is confronting technique challenges. Herein, we propose a comprehensive strategy of searching the urine proteins related with bladder cancer. The strategy consists of three core combinations, screening the biomarker candidates in the secreted proteins derived from the bladder cancer cell lines and verifying them in patient urines, defining the differential proteins through two-dimensional electrophoresis (2DE) and isobaric tags for relative and absolute quantitation (iTRAQ) coupled with LC-MS/MS, and implementing quantitative proteomics of profiling and targeting analysis. With proteomic survey, a total of 700 proteins were found with their abundance of secreted proteins in cancer cell lines different from normal, while 87 proteins were identified in the urine samples. The multiple reaction monitoring (MRM)-based quantification was adapted in verifying the bladder cancer related proteins in individual urine samples, resulting in 10 differential urine proteins linked with the cancer. Of these candidates, receiver operating characteristic analysis revealed that the combination of CO3 and LDHB was more sensitive as the cancer indicator than other groups. The discovery of the bladder cancer indicators through our strategy has paved an avenue to further biomarker validation. PMID:27265680

  18. Quantitative Analysis of 3′-Hydroxynorcotinine in Human Urine

    PubMed Central

    Upadhyaya, Pramod

    2015-01-01

    Introduction: Based on previous metabolism studies carried out in patas monkeys, we hypothesized that urinary 3′-hydroxynorcotinine could be a specific biomarker for uptake and metabolism of the carcinogen N′-nitrosonornicotine in people who use tobacco products. Methods: We developed a method for quantitation of 3′-hydroxynorcotinine in human urine. [Pyrrolidinone-13C4]3′-hydroxynorcotinine was added to urine as an internal standard, the samples were treated with β-glucuronidase, partially purified by solid supported liquid extraction and quantified by liquid chromatography–electrospray ionization–tandem mass spectrometry. Results: The method was accurate (average accuracy = 102%) and precise (coefficient of variation = 5.6%) in the range of measurement. 3′-Hydroxynorcotinine was detected in 48 urine samples from smokers (mean 393±287 pmol/ml urine) and 12 samples from individuals who had stopped smoking and were using the nicotine patch (mean 658±491 pmol/ml urine), but not in any of 10 samples from nonsmokers. Conclusions: Since the amounts of 3′-hydroxynorcotinine found in smokers’ urine were approximately 50 times greater than the anticipated daily dose of N′-nitrosonornicotine, we concluded that it is a metabolite of nicotine or one of its metabolites, comprising perhaps 1% of nicotine intake in smokers. Therefore, it would not be suitable as a specific biomarker for uptake and metabolism of N′-nitrosonornicotine. Since 3′-hydroxynorcotinine has never been previously reported as a constituent of human urine, further studies are required to determine its source and mode of formation. PMID:25324430

  19. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Urine surveillance. 550.41 Section 550.41... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine surveillance. A program of urine testing for drug use shall be established in contract CTCs. (a)...

  20. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Urine surveillance. 550.41 Section 550.41... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine surveillance. A program of urine testing for drug use shall be established in contract CTCs. (a)...

  1. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Urine surveillance. 550.41 Section 550.41... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine surveillance. A program of urine testing for drug use shall be established in contract CTCs. (a)...

  2. 28 CFR 550.41 - Urine surveillance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Urine surveillance. 550.41 Section 550.41... Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.41 Urine surveillance. A program of urine testing for drug use shall be established in contract CTCs. (a)...

  3. Comparative plasma salicylate and urine salicylurate levels following administration of aspirin, magnesium salicylate, and choline magnesium trisalicylate.

    PubMed

    Mason, W D

    1980-11-01

    Eighteen healthy volunteers were administered single doses of commercially available solid dosage forms of aspirin, magnesium salicylate (I), and choline magnesium trisalicylate (II), equivalent to approximately 500 mg of salicylic acid, in a randomized, complete crossover design. Plasma salicylate and urine salicylurate levels were measured by high-pressure liquid chromatography at frequent intervals following dosing; the resultant profiles, areas under the curve (AUC), and percentages of dose excreted as salicylurate were statistically analyzed by an analysis of variance. The plasma salicylate levels following the two dosage forms containing I and II were virtually identical when corrected for small differences in the dose. The plasma salicylic acid level following aspirin was approximately 10% lower during the 1.5--3.0-hr interval due to a portion of unhydrolyzed aspirin, but the dose-corrected AUC for the products tested did not differ significantly (p < 0.05). During the 24 hr following dosing, 66.5 +/- 12.1 68.4 +/- 7.1, and 60.9 +/- 14.1% of the salicylic acid were excreted as urine salicylurate for aspirin, I, and II, respectively, with no significant difference (p < 0.05). Based on this study, there are no significant differences in the rate and extent of absorption of salicylate following the three dosage forms tested, and the elimination kinetics of salicylic acid are not altered by these dosage forms. PMID:7452472

  4. Comparison between microscopical examination of unstained deposits of urine and quantitative culture.

    PubMed

    Littlewood, J M; Jacobs, S I; Ramsden, C H

    1977-11-01

    Side-room examination of fresh samples of urine was compared with the results of surface viable bacterial counts. Examination of centrifuged deposits of urine for bacterial content was shown to compare very well with subsequent culture results. 87% of infected urines were detected, and only 6% of noninfected urines were wrongly identified. Evaluation of the uncentrifuged samples was less easy. There was poor agreement between the naked eye appearance, the presence of protein, and the pus cell count and the ultimate laboratory bacterial count. Microscopy of urinary sediments after centrifuging is recommended to assist in the rapid diagnosis of urinary tract infections particularly in young children. PMID:339849

  5. NMR Chemical Shift Ranges of Urine Metabolites in Various Organic Solvents.

    PubMed

    Görling, Benjamin; Bräse, Stefan; Luy, Burkhard

    2016-01-01

    Signal stability is essential for reliable multivariate data analysis. Urine samples show strong variance in signal positions due to inter patient differences. Here we study the exchange of the solvent of a defined urine matrix and how it affects signal and integral stability of the urinary metabolites by NMR spectroscopy. The exchange solvents were methanol, acetonitrile, dimethyl sulfoxide, chloroform, acetone, dichloromethane, and dimethyl formamide. Some of these solvents showed promising results with a single batch of urine. To evaluate further differences between urine samples, various acid, base, and salt solutions were added in a defined way mimicking to some extent inter human differences. Corresponding chemical shift changes were monitored. PMID:27598217

  6. Recovery of intravenously infused chromium EDTA and lithium sulphate in the urine of cattle and their use as markers to measure urine volume.

    PubMed

    Bowen, M K; Poppi, D P; McLennan, S R

    2009-04-01

    A series of metabolism experiments investigated the recovery of continuous-, intravenously infused chromium complexed with ethylenediamine tetra-acetic acid (CrEDTA) and lithium sulphate in the urine of cattle with a view to using the markers to estimate urine and metabolite output in grazing cattle. The recovery of Cr in urine from these infusions was similar (90%) in metabolism trials when cattle consumed three very contrasting diets: high-grain formulated pellet, lucerne hay (Medicago sativa) or low-quality native grass hay (predominantly Heteropogon contortus). By contrast, Li recovery in urine averaged 46.3 ± 0.40% and 72.6 ± 0.43% for native pasture and lucerne hays, respectively, but was not constant across days. There was negligible transfer of Cr from CrEDTA in blood serum to the rumen or faeces, whereas appreciable quantities of infused Li were found in both. The ratio of urine volume estimated by spot samples and marker dilution of Cr, to urine volume measured gravimetrically, was 1.05. In grazing studies using rumen-fistulated (RF) steers grazing seven different tropical and temperate grass and legume pastures, the ratio of concentrations of purine derivatives (PD) to Cr in spot samples of urine was shown to vary diurnally in the range of 49% to 157% of the average 24 h value. This finding indicated the need for regular sampling of urine to achieve an accurate average value for the PD : Cr ratio in urine for use in estimating urinary PD excretion and hence microbial protein production in the rumen. It was concluded that continuous, intravenous infusion of CrEDTA resulted in a constant recovery of Cr in the urine of cattle across diets and, provided an intensive sampling regime was followed to account for diurnal variation, it would be suitable as a marker to estimate urine volume and urinary output of PD in grazing cattle. PMID:22444379

  7. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing

    PubMed Central

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  8. Long-Term Follow-up of HPV Infection Using Urine and Cervical Quantitative HPV DNA Testing.

    PubMed

    Vorsters, Alex; Van Keer, Severien; Biesmans, Samantha; Hens, Annick; De Coster, Ilse; Goossens, Herman; Ieven, Margareta; Van Damme, Pierre

    2016-01-01

    The link between infection with high-risk human papillomavirus (hrHPV) and cervical cancer has been clearly demonstrated. Virological end-points showing the absence of persistent HPV infection are now accepted as a way of monitoring the impact of prophylactic vaccination programs and therapeutic vaccine trials. This study investigated the use of urine samples, which can be collected by self-sampling at home, instead of cervical samples for follow-up of an HPV intervention trial. Eighteen initially HPV DNA-positive women participating in an HPV therapeutic vaccine trial were monitored during a three-year follow-up period. A total of 172 urine samples and 85 cervical samples were collected. We obtained a paired urine sample for each of the 85 cervical samples by recovering urine samples from six monthly gynaecological examinations. We performed a small pilot study in which the participating women used a urine collection device at home and returned their urine sample to the laboratory by mail. All samples were analyzed using quantitative real-time HPV DNA PCR. A good association (κ value of 0.65) was found between the presence of HPV DNA in urine and a subsequent cervical sample. Comparisons of the number of HPV DNA copies in urine and paired cervical samples revealed a significant Spearman rho of 0.676. This correlation was superior in women with severe lesions. The HPV DNA results of the small pilot study based on self-collected urine samples at home are consistent with previous and subsequent urine and/or cervical results. We demonstrated that urine sampling may be a valid alternative to cervical samples for the follow-up of HPV intervention trials or programs. The potential clinical value of urine viral load monitoring should be further investigated. PMID:27196899

  9. Plasma and urine diketopiperazine concentrations in normal adults ingesting large quantities of aspartame.

    PubMed

    Cho, E S; Coon, J D; Stegink, L D

    1987-07-01

    In aqueous solution, aspartame can cyclicize to form its corresponding diketopiperazine (3-carboxymethyl-6-benzyl-2,5-diketopiperazine; DKP) and methanol. We measured plasma and urinary concentrations of DKP in samples obtained from six normal adult subjects ingesting 2.2 mg DKP/kg body weight. The DKP was administered as part of a dose of 200 mg aspartame/kg body weight. DKP concentrations in plasma were below the detection limit (less than 1 microgram/ml) of the high-pressure liquid chromatographic method at each time interval after ingestion at which they were measured. Mean (+/- SD) total urinary DKP excreted during the first 24-hr period after dosing was 6.68 +/- 1.30 mg (4.83 +/- 0.23% of the ingested DKP dose). Approximately 44% of the total DKP excreted was excreted in the first 4 hr after dosing. PMID:3623338

  10. Performance of Copan WASP for Routine Urine Microbiology

    PubMed Central

    Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.

    2015-01-01

    This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255

  11. The role of urine toxicology in chronic opioid analgesic therapy.

    PubMed

    Compton, Peggy

    2007-12-01

    The current trend of treating chronic nonmalignant pain with opioid therapy means that pain management nurses are increasingly involved in the care of patients who are prescribed and using potent opioid analgesics on a daily basis. Although demonstrated to be quite effective in certain patients, sanctioned access to these medications brings with it risks for abuse, addiction, and diversion. Urine toxicology analysis is a valuable, yet underutilized, tool to monitor patterns of medication use and potential use of illicit drugs to evaluate the effect of these on health outcomes. This review provides a guide for the use of urine toxicology in the nursing management of chronic pain patients on opioid therapy, detailing the information provided by urine toxicology analysis, the benefits and limitations of urine drug testing, principles of sample collection, and correct interpretation of findings. It is emphasized that the results of urine toxicology analysis should never be used in isolation to identify abuse, addiction, or diversion, and that patterns of medication and other drug use should always be evaluated with respect to evidence of improved functionality. Nurses involved in the care of patients with chronic pain are encouraged to consider urine toxicology analysis as an integral component in care plan for those on chronic opioid therapy, and to knowledgeably implement and interpret this powerful tool in the practice of pain care. PMID:18036504

  12. Urine oxalate biological variation in patients with primary hyperoxaluria.

    PubMed

    Clifford-Mobley, Oliver; Sjögren, Anna; Lindner, Elisabeth; Rumsby, Gill

    2016-08-01

    Hyperoxaluria is a well-recognised risk factor for urolithiasis and patients with primary hyperoxaluria (PH) gradually build up calcium oxalate deposits leading to chronic kidney disease. Efforts to improve treatment for PH have focused on reducing urine oxalate excretion and thus decreasing lithogenesis. To determine the efficacy of treatments designed to alter a biochemical parameter it is necessary to know the biological and analytical variation of that parameter. In this study, we estimated the intra-individual biological variation of urine oxalate excretion in patients with PH, and from this determined what would constitute a significant change in the form of a reference change value (RCV). Each patient collected four 24-h urines on consecutive weeks. The intra-individual biological variation of oxalate excretion calculated from these samples ranged from 0 to 36 % with a mean of 14 %. The corresponding RCVs were 4-84 % with a mean of 32 %. This result implies that, on average, a reduction of almost one-third in urine oxalate excretion is required to prove an effect from treatment. The wide range of biological variation between individuals may reflect other, as yet unknown, determinants of oxaluria in PH, as well as inaccuracies in urine collection. The data suggest that it is more appropriate to use individual RCVs established prior to treatment to determine its efficacy: a relatively small fall in urine oxalate excretion may be outside the biological variation of some patients but not of others. PMID:26857252

  13. Quantitation of products from riboflavin in rat urine

    SciTech Connect

    Chastain, J.L.; McCormick, D.B.

    1986-03-05

    When (2-/sup 14/C) riboflavin is injected i.p. into rats, the excreted vitamin in urine and feces has been shown to be the intact vitamin with trace amounts of lumichrome and lumiflavin. Recent findings with /sup 14/C-riboflavin fed to rats indicated higher levels of riboflavin catabolites in urine, e.g., 7- and 8-carboxylumichromes. The authors have determined catabolites in urine from male rats fed 0, 2, and 6 ..mu..g riboflavin/g diet/day for six weeks. Two rats from each group were placed weekly in metabolic cages, and urine was collected for 24 hours. On the fourth week, a third animal from each group received an i.p. injection of /sup 14/C-riboflavin and the urine was collected for 48 hours. Urine samples were extracted with phenol for flavin components and with chloroform for derivatives of lumichrome and lumiflavin. Riboflavin was the predominant flavin excreted by all diet groups with trace amounts of coenzymes and 7- and 8-hydroxymethylriboflavin. Riboflavin accounted for 85% of all the radioactivity recovered from the deficient and sufficient rats and 90% in rats fed excess. Lumichrome-type compounds including carboxylumichromes accounted for only a few % of recovered radioactivity. Thus, these components are primarily a product of intestinal microfloral degradation rather than significant tissue catabolites of riboflavin.

  14. Ethylglucuronide determination in urine and hair from alcohol withdrawal patients.

    PubMed

    Concheiro, Marta; Cruz, Angelines; Mon, Marisol; de Castro, Ana; Quintela, Oscar; Lorenzo, Angeles; López-Rivadulla, Manuel

    2009-04-01

    Two methods for the determination of ethylglucuronide (EtG) in urine and in hair have been developed by liquid chromatography- tandem mass spectrometry. These two methods were fully validated, including linearity (0.25-100 microg/mL in urine; 0.05-5 ng/mg in hair; r(2) > 0.99, n = 5), limits of detection (0.1 microg/mL in urine, 0.025 ng/mg in hair) and quantitation (lowest level of the calibration curve), extraction efficiency (> 55%), within-day and between-day imprecision and bias (CV and mean relative error < 15%), matrix effect, and relative ion intensity. These methods have been applied to 541 urine samples and 17 hair specimens collected from 156 alcohol withdrawal patients. The determination of ethanol versus EtG in urine was compared, and also the convenience of EtG determination in hair. EtG in urine and in hair proved to be a powerful tool for monitoring abstinence in these patients. PMID:19371464

  15. [Methods of urine analysis for creatinine after long period of storage].

    PubMed

    Pishak, V P; Iarmol'chuk, S G

    2001-01-01

    Our investigations showed that n-cresol (4-methylphenol) stabilized urine and preserves urinal creatinine as long as for 50-d storage at room temperature. This antimicrobial biochemical stabilizer is the core of a novel method of delayed creatinine quantification in urine. It can be useful in metabolic investigations of cosmonauts and nuclear submarine crews, members of alpine, desert, deep-water, Arctic and Antarctic expeditions and in many other cases when samples cannot be analyzed immediately. PMID:11385990

  16. Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

    NASA Technical Reports Server (NTRS)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2015-01-01

    An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS). The bioavailability and pharmacokinetics (PK) were evaluated under IND (Investigational New Drug) guidelines. The aim of the project was to develop a PK model that can predict the relationships among plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial protocol with INSCOP. Twelve healthy human subjects were administered at three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. PK compartmental models, using actual dosing and sampling time, were established using Phoenix (version 1.2). Model selection was based on a likelihood ratio test on the difference of criteria (-2LL (i.e. log-likelihood ratio test)) and comparison of the quality of fit plots. The results: Predictable correlations among scopolamine concentrations in compartments of plasma, saliva and urine were established, and for the first time the model satisfactorily predicted the population and individual PK of INSCOP in plasma, saliva and urine. The model can be utilized to predict the INSCOP plasma concentration by saliva and urine data, and it will be useful for monitoring the PK of scopolamine in space and other remote environments using non-invasive sampling of saliva and/or urine.

  17. Creating a urine black hole

    NASA Astrophysics Data System (ADS)

    Hurd, Randy; Pan, Zhao; Meritt, Andrew; Belden, Jesse; Truscott, Tadd

    2015-11-01

    Since the mid-nineteenth century, both enlisted and fashion-conscious owners of khaki trousers have been plagued by undesired speckle patterns resulting from splash-back while urinating. In recent years, industrial designers and hygiene-driven entrepreneurs have sought to limit this splashing by creating urinal inserts, with the effectiveness of their inventions varying drastically. From this large assortment of inserts, designs consisting of macroscopic pillar arrays seem to be the most effective splash suppressers. Interestingly this design partially mimics the geometry of the water capturing moss Syntrichia caninervis, which exhibits a notable ability to suppress splash and quickly absorb water from impacting rain droplets. With this natural splash suppressor in mind, we search for the ideal urine black hole by performing experiments of simulated urine streams (water droplet streams) impacting macroscopic pillar arrays with varying parameters including pillar height and spacing, draining and material properties. We propose improved urinal insert designs based on our experimental data in hopes of reducing potential embarrassment inherent in wearing khakis.

  18. The effect of urine storage on antiviral and antibiotic compounds in the liquid phase of source-separated urine.

    PubMed

    Jaatinen, Sanna T; Palmroth, Marja R T; Rintala, Jukka A; Tuhkanen, Tuula A

    2016-09-01

    The behaviour of pharmaceuticals related to the human immunodeficiency virus treatment was studied in the liquid phase of source-separated urine during six-month storage at 20°C. Six months is the recommended time for hygienization and use of urine as fertilizer. Compounds were spiked in urine as concentrations calculated to appear in urine. Assays were performed with separate compounds and as therapeutic groups of antivirals, antibiotics and anti-tuberculotics. In addition, urine was amended either with faeces or urease inhibitor. The pharmaceutical concentrations were monitored from filtered samples with solid phase extraction and liquid chromatography. The concentration reductions of the studied compounds as such or with amendments ranged from less than 1% to more than 99% after six-month storage. The reductions without amendments were 41.9-99% for anti-tuberculotics; <52% for antivirals (except with 3TC 75.6%) and <50% for antibiotics. In assays with amendments, the reductions were all <50%. Faeces amendment resulted in similar or lower reduction than without it even though bacterial activity should have increased. The urease inhibitor prevented ureolysis and pH rise but did not affect pharmaceutical removal. In conclusion, removal during storage might not be enough to reduce risks associated with the studied pharmaceuticals, in which case other feasible treatment practises or urine utilization means should be considered. PMID:26804243

  19. A New Method to Make 24-Hour Urine Collection More Convenient: A Validity Study

    PubMed Central

    2014-01-01

    Background and Objectives. This study proposes a novel urine collection device that can divide each urine collection into 20 parts and store and cool just one part. The aim of the current study is to compare measured biomarkers from the proposed urine collection device to those of conventional 24-hour sampling method. We also hypothesized that the new method would significantly increase patients' adherence to the timed urine collection. Methods. Two 24-hour urine samples with the conventional method and with the new automated urine collection device that uses just one-twentieth of each void were obtained from 40 healthy volunteers. Urine parameters including volume, creatinine, and protein levels were compared between the two methods and the agreement of two measurements for each subject was reported through Bland-Altman plots. Results. Our results confirmed that for all three variables, there is a positive correlation (P < 0.001) between the two measurements and high degree of agreement could be seen in Bland-Altman plots. Moreover, more subjects reported the new method as “more convenient” for 24-hour urine collection. Conclusions. Our results clearly indicate that a fixed proportion of each void may significantly reduce the urine volume in timed collections and this, in turn, may increase subjects' adherence to this difficult sampling. PMID:24963405

  20. Cocaine metabolite (benzoylecgonine) in hair and urine of drug users.

    PubMed

    Martinez, F; Poet, T S; Pillai, R; Erickson, J; Estrada, A L; Watson, R R

    1993-01-01

    Two methods of drug detection, urinalysis and hair analysis, were compared with respect to the efficiency of identification of drug use in a population of men living on the Arizona-Mexico border. The standard curve of cannabinoids in urine was linear to 20 ng/mL. The GC/MS levels for all cannabinoids combined in urine were very similar to that obtained by radioimmunoassay (RIA), 91% concordance. Similar results were obtained from samples analyzed dually for the cocaine metabolite benzoylecgonine (BE) after spiking. As determined by RIA of urine, 74% of the subjects were positive for cannabinoids. The majority were in the range of 100-1000 ng/mg creatinine. The pattern of excretion of THC metabolites with respect to the verbally reported time of first use was fairly normal, with the peak rate of elimination 13-24 hours following the last reported use. Washed hair samples were extracted by overnight acid hydrolysis. Urine samples and neutralized hair extracts were analyzed for cocaine and BE by RIA. Of the hair samples, 55% contained cocaine/BE, as compared with only 4.3% of the urine samples. Most hair samples contained cocaine/BE in the range of 25-100 ng/sample (100 mg hair). All hair samples testing negative for cocaine/BE by RIA also tested negative by GC/MS, and four samples containing the highest amounts of cocaine and BE by RIA were similarly found to contain the highest amounts by GC/MS. Hair analysis, therefore, gives a wider window of detection of drug use than does urinalysis and shows merit in the confirmation of cocaine use in small clinical research studies. PMID:8336486

  1. [Determination of dimethylbenzoic acid isomers in urine by gas chromatography].

    PubMed

    Kostrzewski, P; Wiaderna-Brycht, A; Czerski, B

    1994-01-01

    Trimethylobenzene (TMB) is a main ingredient of many organic solvents used in industry. In Farbasol (Polish trade name of the solvent) TMB occurs as a mixture of three isomers: pseudocumene (1, 2, 4-TMB) 30%; mesitylene (1, 3, 5-TMB) 15%; hemimellitene (1,2,3-TMB) 5%. As it is known in human organism, TMB is metabolized mainly to dimethylbenzoic (DMBA) and dimethylhippuric (DMHA) acids, and some authors suggest, that the acids excreted in urine can be biological indicators of exposure to TMB. This study was aimed at developing the method of determination of DMBA isomers in urine. Biological material was hydrolyzed with sodium hydroxide and next extracted with diethyl ether. DMBA concentration in urine was determined by gas chromatography using a variant of quantitative analysis with internal standard (5-methyl-2-isopropylphenol, thymol). Analytical parameters of the developed method of determination of DMBA isomers in urine such as linearity, precision, reproducibility, stability (192 days, when urine samples stored at-18 degrees C), detectability limit (400 micrograms/dm3) have been fully compatible with the requirements of biological monitoring. In order to confirm the presence of DMBA isomers in urine, four volunteers were exposed (8 hours) to Farbasol in toxicological chamber. The TMB concentration in the air, determined by means of gas chromatograph (HP 5890), amounted to 100 mg/m3 (MAC value in Poland). In urine samples collected 2,3-; 2,4-; 2,5-; 2,6-; 3,4-; 3,5-dimethylbenzoic acids were identified by means of GC/MSD.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8170375

  2. Urine oligosaccharide pattern in patients with hyperprolactinaemia.

    PubMed

    Ekman, Bertil; Wahlberg, Jeanette; Landberg, Eva

    2015-11-01

    Free milk-type oligosaccharides are produced during pregnancy and lactation and may have an impact on several cells in the immune system. Our aim was to investigate if patients with isolated hyperprolactinaemia, not related to pregnancy, also have increased synthesis and urinary excretion of milk-type oligosaccharides and to compare the excretion pattern with that found during pregnancy. Urine samples were collected as morning sample from 18 patients with hyperprolactinaemia, 13 healthy controls with normal prolactin levels and four pregnant women. After purification, lactose and free oligosaccharides were analysed and quantified by high-performance anion-exchange chromatography with pulsed amperometric detection. The identity of peaks was confirmed by exoglycosidase treatment and comparison with oligosaccharide standards. Prolactin was measured in serum collected between 09 and 11 a.m. by a standardized immunochemical method. Patients with hyperprolactinaemia had higher urinary excretion of lactose than normoprolactinemic controls and urinary lactose correlated positively to prolactin levels (r = 0.51, p < 0.05). Increased levels of the fucosylated oligosaccharides 2-fucosyl lactose and lacto-di-fucotetraose were found in urine from three and two patients, respectively. The acidic oligosaccharide 3-sialyl lactose was found in high amount in urine from two patients with prolactin of >10,000 mU/l. However, pregnant women in their third trimester had the highest concentration of all these oligosaccharides and excretion increased during pregnancy. This study is first to show that both lactose and certain fucosylated and sialylated milk-type oligosaccharides are increased in some patients with hyperprolactinaemia. It remains to elucidate the functional importance of these findings. PMID:26275984

  3. The International Space Station Urine Monitoring System (UMS)

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Cibuzar, Branelle R.; Milstead, Jeffery R.; Pietrzyk,, Robert A.; Clark, Mark S.F.

    2009-01-01

    A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification

  4. Urine naloxone concentration at different phases of buprenorphine maintenance treatment.

    PubMed

    Heikman, Pertti; Häkkinen, Margareeta; Gergov, Merja; Ojanperä, Ilkka

    2014-03-01

    In spite of the benefits of buprenorphine-naloxone co-formulation (BNX) in opioid maintenance treatment, the naloxone component has not prevented parenteral use of BNX. Current laboratory methods are not sufficient to differentiate between therapeutic and illicit use of buprenorphine, and little is known about urine naloxone concentrations. Measurement of urine naloxone, together with buprenorphine and norbuprenorphine, might help to determine the naloxone source and administration route. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for this purpose. Naloxone, buprenorphine, and norbuprenorphine total concentrations were measured in urine samples from opioid-dependent patients before and during stable and unstable phases of maintenance treatment with BNX. The limit of quantification in urine was 1.0 µg/L for naloxone, buprenorphine and norbuprenorphine. Before treatment, all samples contained buprenorphine but the median naloxone concentration was 0 µg/L. During the maintenance treatment with BNX all urine samples were positive for naloxone, buprenorphine and norbuprenorphine. The naloxone concentration at a stable phase of treatment (median 60 µg/L, range 5-200 µg/L) was not different from the naloxone concentration at an unstable phase (70 µg/L, 10-1700 µg/L). Applying an upper limit of 200 µg/L to the sample, the median naloxone/buprenorphine ratio was higher in the high than in the low naloxone concentration group (0.9 vs 0.3, respectively). This study suggests that naloxone in urine can act as an indicator of compliance with BNX. Parenteral use of BNX was associated with a high naloxone/buprenorphine ratio. Negative naloxone with positive buprenorphine suggests the use/abuse of buprenorphine alone. PMID:23512803

  5. Urine Metabolite Profiles Predictive of Human Kidney Allograft Status.

    PubMed

    Suhre, Karsten; Schwartz, Joseph E; Sharma, Vijay K; Chen, Qiuying; Lee, John R; Muthukumar, Thangamani; Dadhania, Darshana M; Ding, Ruchuang; Ikle, David N; Bridges, Nancy D; Williams, Nikki M; Kastenmüller, Gabi; Karoly, Edward D; Mohney, Robert P; Abecassis, Michael; Friedewald, John; Knechtle, Stuart J; Becker, Yolanda T; Samstein, Benjamin; Shaked, Abraham; Gross, Steven S; Suthanthiran, Manikkam

    2016-02-01

    Noninvasive diagnosis and prognostication of acute cellular rejection in the kidney allograft may help realize the full benefits of kidney transplantation. To investigate whether urine metabolites predict kidney allograft status, we determined levels of 749 metabolites in 1516 urine samples from 241 kidney graft recipients enrolled in the prospective multicenter Clinical Trials in Organ Transplantation-04 study. A metabolite signature of the ratio of 3-sialyllactose to xanthosine in biopsy specimen-matched urine supernatants best discriminated acute cellular rejection biopsy specimens from specimens without rejection. For clinical application, we developed a high-throughput mass spectrometry-based assay that enabled absolute and rapid quantification of the 3-sialyllactose-to-xanthosine ratio in urine samples. A composite signature of ratios of 3-sialyllactose to xanthosine and quinolinate to X-16397 and our previously reported urinary cell mRNA signature of 18S ribosomal RNA, CD3ε mRNA, and interferon-inducible protein-10 mRNA outperformed the metabolite signatures and the mRNA signature. The area under the receiver operating characteristics curve for the composite metabolite-mRNA signature was 0.93, and the signature was diagnostic of acute cellular rejection with a specificity of 84% and a sensitivity of 90%. The composite signature, developed using solely biopsy specimen-matched urine samples, predicted future acute cellular rejection when applied to pristine samples taken days to weeks before biopsy. We conclude that metabolite profiling of urine offers a noninvasive means of diagnosing and prognosticating acute cellular rejection in the human kidney allograft, and that the combined metabolite and mRNA signature is diagnostic and prognostic of acute cellular rejection with very high accuracy. PMID:26047788

  6. Urine as a biological specimen for forensic analysis of alcohol and variability in the urine-to-blood relationship.

    PubMed

    Jones, Alan W

    2006-01-01

    This article concerns the use of urine as a biological specimen for determination of alcohol in clinical and forensic toxicology and discusses factors that might influence variability in the urine/blood concentration ratio of alcohol. A large number of human drinking experiments were conducted to determine the time course of urine-alcohol concentrations (UAC) in relation to blood-alcohol concentrations (BAC). The UAC and BAC curves were shifted in time and the BAC curve always began to decrease before the UAC started to decline. During the early absorption phase the UAC/BAC ratio was less than unity, whereas in the late absorption/distribution period the ratio was between 1.0-1.2. On reaching the post-absorptive phase, the UAC always exceeded BAC and UAC/BAC ratios averaged 1.3-1.4, increasing appreciably as BAC decreased towards zero. Alcohol-induced diuresis was most pronounced during the rising portion of the BAC curve and near to the peak value. After about 2 hours post-drinking, the production rate of urine diminished to the pre-drinking rate of about 0.5-1 mL/min. Drinking water during the post-absorptive phase of the alcohol curve produced dilute urine, as reflected in lower creatinine content and osmolality, although the concentration of ethanol remained unchanged. After subjects drank a moderate dose of ethanol (0.54-0.85 g/kg) about 2% of the dose was recoverable in the urine after 7 hours. Ethyl glucuronide, a minor metabolite of ethanol, was measured in urine samples from drunk drivers. The UAC/BAC ratio of ethanol in drunk drivers did not depend on the creatinine content of the urine and therefore the relative dilution of the specimens. When alcohol-free urine was spiked with glucose and infected with the yeast species Candida albicans, ethanol was produced by fermentation after approximately 24 hours storage at room temperature. This post-sampling synthesis of ethanol was prevented by sodium fluoride (1% weight by volume) in the urine tubes or by

  7. Measurement of the glucose concentration in human urine with optical refractometer

    NASA Astrophysics Data System (ADS)

    Wu, Rui-Yang; Hsu, Cheng-Chih; Meng, Ching-Tang; Cheng, Chih-Ching; Liao, Yu-Ching

    2015-07-01

    In this paper, a new type of human urine glucose measurement system is proposed. We measured the phase variation of human urine with/without glucose-urine mixture (to simulate diabetes mellitus). We were able to achieve high resolution with the proposed method. The relation curve between the phase difference and glucose concentration can be estimated, and the glucose concentration of a urine sample can be determined by using this relation curve. The proposed method showed that theoretical resolution is approximated of 1.47 mg/dl.

  8. The Use of Chlorhexidine/n-Propyl Gallate (CPG) as an Ambient-Temperature Urine Preservative

    NASA Technical Reports Server (NTRS)

    Nillen, Jeannie L.; Smith, Scott M.

    2003-01-01

    A safe, effective ambient temperature urine preservative, chlorhexidine/n-propyl gallate (CPG), has been formulated for use during spacefli ght that reduces the effects of oxidation and bacterial contamination on sample integrity while maintaining urine pH. The ability of this preservative to maintain stability of nine key analytes was evaluated for a period of one year. CPG effectively maintained stability of a mmonia, total nitrogen, 3-methylhistidine, chloride, sodium, potassiu m, and urea; however, creatinine and osmolality were not preserved by CPG. These data indicate that CPG offers prolonged room-temperature storage for multiple urine analytes, reducing the requirements for f rozen urine storage on future spaceflights. Iii medical applications on Earth, this technology can allow urine samples to be collected in remote settings and eliminate the need to ship frozen samples.

  9. Mutagenicity in Salmonella of hazardous wastes and urine from rats fed these wastes

    SciTech Connect

    DeMarini, D.M.; Inmon, J.P.; Simmons, J.E.; Berman, E.; Pasley, T.C.

    1987-01-01

    15 hazardous industrial-waste samples were evaluated for mutagenicity in the Salmonella plate-incorporation assay using strains TA98 and TA100 in the presence and absence of Aroclor 1254-induced rat liver S9. Dichloromethane/methanol extracts of the crude wastes were also evaluated. 7 of the crude wastes were mutagenic, but only 2 of the extracts of these 7 wastes were mutagenic; extracts of 2 additional wastes also were mutagenic. In addition, 10 of the crude wastes were administered by gavage to F-344 rats, and 24-h urine samples were collected. Of the 10 raw urines evaluated, 3 were mutagenic in strain TA98 in the presence of S9 and beta-glucuronidase. The 3 crude wastes that produced these 3 mutagenic urines were, themselves, mutagenic. Adequate volumes of 6 of the 10 raw urines were available for extraction/concentration. These 6 urines were incubated with beta-glucuronidase and eluted through Sep-Pak C18 columns; the methanol eluates of 3 of the urines were mutagenic, and these were the same 3 whose raw urines also were mutagenic. In general, the C18/methanol extraction procedure reduced the cytotoxicity and increased the mutagenic potency of the urines. To the authors knowledge, this is the first report of the mutagenicity of urine from rodents exposed to hazardous wastes.

  10. Ebola Virus RNA Stability in Human Blood and Urine in West Africa’s Environmental Conditions

    PubMed Central

    Delaune, Deborah; Poyot, Thomas; Valade, Eric; Mérens, Audrey; Rollin, Pierre E.; Foissaud, Vincent

    2016-01-01

    We evaluated RNA stability of Ebola virus in EDTA blood and urine samples collected from infected patients and stored in West Africa’s environmental conditions. In blood, RNA was stable for at least 18 days when initial cycle threshold values were <30, but in urine, RNA degradation occurred more quickly. PMID:26812135

  11. METHOD FOR THE CONFIRMATION OF CHLOROPHENOLS IN HUMAN URINE BY LC WITH AN ELECTROCHEMICAL DETECTOR

    EPA Science Inventory

    A method is described for the confirmation of chlorophenols in human urine. A hydrolyzed urine sample is analyzed by both gas chromatography (GC), and liquid chromatography (LC) with electrochemical detection and the results compared. A discussion of these results, including fact...

  12. Highly sensitive electromembrane extraction for the determination of volatile organic compound metabolites in dried urine spot.

    PubMed

    Suh, Joon Hyuk; Eom, Han Young; Kim, Unyong; Kim, Junghyun; Cho, Hyun-Deok; Kang, Wonjae; Kim, Da Som; Han, Sang Beom

    2015-10-16

    Electromembrane extraction coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for determination of ten volatile organic compound metabolites in dried urine spot samples. The dried urine spot approach is a convenient and economical sampling method, wherein urine is spotted onto a filter paper and dried. This method requires only a small amount of sample, but the analysis sometimes suffers from low sensitivity, which can lead to analytical problems in the detection of minor components in samples. The newly developed dried urine spot analysis using electromembrane extraction exhibited improved sensitivity and extraction, and enrichment of the sample was rapidly achieved in one step by applying an electric field. Aliquots of urine were spotted onto Bond Elut DMS cards and dried at room temperature. After drying, the punched out dried urine spot was eluted with water. Volatile organic compound metabolites were extracted from the sample through a supported liquid membrane into an alkaline acceptor solution inside the lumen of a hollow fiber with the help of an electric potential. The optimum extraction conditions were determined by using design of experiments (fractional factorial design and response surface methodology). Satisfactory sensitivity was achieved and the limits of quantification (LOQ) obtained were lower than the regulatory threshold limits. The method was validated by assessing the linearity, precision, accuracy, recovery, reproducibility, stability, and matrix effects. The results were acceptable, and the developed method was successfully applied to biological exposure monitoring of volatile organic compound metabolites in fifty human urine samples. PMID:26385086

  13. Tryptophan glycoconjugates in food and human urine.

    PubMed Central

    Gutsche, B; Grun, C; Scheutzow, D; Herderich, M

    1999-01-01

    Evaluating the formation of tryptophan glycoconjugates other than well-established Amadori rearrangement products, HPLC-tandem MS (MS/MS) analysis of human urine collected from several healthy individuals proved the presence of one distinct tryptophan C-glycosyl compound [Horiuchi, Yonekawa, Iwahara, Kanno, Kurihara and Fujise (1994) J. Biochem. (Tokyo) 115, 362-366]. After isolation, unambiguous identification of this novel tryptophan metabolite as 2-(alpha-mannopyranosyl)-l-tryptophan was achieved by tandem MS combined with NMR spectroscopy including homonuclear COSY, heteronuclear multiple-bond connectivity and (1)H-detected heteronuclear multiple-quantum coherence experiments. Remarkably, a thorough evaluation of vicinal proton-proton coupling constants in different solvents and nuclear Overhauser effect experiments demonstrate the predominant axial orientation of the hydroxymethyl group of the hexopyranosyl residue. Likewise this spatial arrangement indicates that the respective alpha-anomeric C-mannosylhexopyranose is preferentially adopting a (1)C(4) conformation in acidic methanol. Whereas only one distinct tryptophan mannoconjugate could be observed in human urine, HPLC-MS/MS analysis of food samples for the first time led to the identification of numerous N(1)-(beta-d-hexopyranosyl)-l-tryptophan, 2-(beta-d-hexopyranosyl)-l-tryptophan and 1-(1,2,3,4,5-pentahyd- roxypent-1-yl)-1,2,3,4-tetrahydro-beta-carboline-3-carboxylic acid derivatives derived from the condensation of tryptophan with aldohexoses. Taking into consideration the significant differences between profiles and configurations of tryptophan glycoconjugates originating from dietary sources and human urine, C-2 mannosylation of tryptophan residues [de Beer, Vliegenthart, Loeffler and Hofsteenge (1995) Biochemistry 34, 11785-11789] represents a novel enzymic pathway in tryptophan metabolism in humans. PMID:10493906

  14. DETERMINATION OF RACTOPAMINE IN CATTLE AND SHEEP URINE USING BIOSENSOR

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A biosensor method, using the surface plasmon resonance (SPR) principle, was developed for the determination of ractopamine in cattle and sheep urine. A monoclonal antibody was used to compete with ractopamine in the sample and ractopamine immobilized on the sensor chip. Addition of bovine serum a...

  15. Sysmex UF-1000i performance for screening yeasts in urine.

    PubMed

    Gutiérrez-Fernández, José; Riazzo, Cristina; Sanbonmatsu, Sara; de Dios Luna, Juan; Sorlózano, Antonio; Miranda, Consuelo; Navarro, José María

    2014-04-01

    We tested the capacity of the Sysmex UF-1000i system to detect yeasts in urine by screening a total of 22 132 urine samples received for culture in our microbiology laboratory during 1 year. We also analyzed different dilutions of previously filtered urine inoculated with a strain of Candida albicans. With clinical samples, a single cut-off point of 50 yeast-like cells (YLCs)/μL detected candiduria ≥10 000 colony forming units (CFU)/mL and >100 000 CFU/mL with a sensitivity of 87.3%/95.4%, a specificity of 97%, a negative predictive value of 95.9%, and a positive predictive value of 9.3%/5.7%. With the simulated samples, a linear relationship was observed between the dilution factor and the number of cells detected by UF-1000i. This instrument appears to be able to reliably rule out candiduria of a magnitude of at least 10 000 CFU/mL and facilitate urine sample screening, thereby providing fast results. The Sysmex UF1000i system can be adapted for candiduria screening by the use of an appropriate YLCs/μL cut-off point that takes account of the prevalence of candiduria in the population. PMID:23919730

  16. Smartphone based point-of-care detector of urine albumin

    NASA Astrophysics Data System (ADS)

    Cmiel, Vratislav; Svoboda, Ondrej; Koscova, Pavlina; Provaznik, Ivo

    2016-03-01

    Albumin plays an important role in human body. Its changed level in urine may indicate serious kidney disorders. We present a new point-of-care solution for sensitive detection of urine albumin - the miniature optical adapter for iPhone with in-built optical filters and a sample slot. The adapter exploits smart-phone flash to generate excitation light and camera to measure the level of emitted light. Albumin Blue 580 is used as albumin reagent. The proposed light-weight adapter can be produced at low cost using a 3D printer. Thus, the miniaturized detector is easy to use out of lab.

  17. Managing Chemotherapy Side Effects: Urination Changes

    MedlinePlus

    ... nurse if you have any of these changes: l A strong urge to urinate more often l Urine that is cloudy, or is a different ... such as orange, red, green, or dark yellow l Urine that has a strong smell l Trouble ...

  18. Getting a Urine Test (For Kids)

    MedlinePlus Videos and Cool Tools

    ... Help White House Lunch Recipes Getting a Urine Test (Video) KidsHealth > For Kids > Getting a Urine Test (Video) Print A A A Text Size en ... cup, but docs learn a lot from urine tests. Obviously, this test doesn't hurt. And if ...

  19. Detection of depleted uranium in urine of veterans from the 1991 Gulf War.

    PubMed

    Gwiazda, R H; Squibb, K; McDiarmid, M; Smith, D

    2004-01-01

    American soldiers involved in "friendly fire" accidents during the 1991 Gulf War were injured with depleted-uranium-containing fragments or possibly exposed to depleted uranium via other routes such as inhalation, ingestion, and/or wound contamination. To evaluate the presence of depleted uranium in these soldiers eight years later, the uranium concentration and depleted uranium content of urine samples were determined by inductively coupled plasma mass spectrometry in (a) depleted uranium exposed soldiers with embedded shrapnel, (b) depleted uranium exposed soldiers with no shrapnel, and (c) a reference group of deployed soldiers not involved in the friendly fire incidents. Uranium isotopic ratios measured in many urine samples injected directly into the inductively coupled plasma mass spectrometer and analyzed at a mass resolution m/delta m of 300 appeared enriched in 235U with respect to natural abundance (0.72%) due to the presence of an interference of a polyatomic molecule of mass 234.81 amu that was resolved at a mass resolution m/delta m of 4,000. The 235U abundance measured on uranium separated from these urines by anion exchange chromatography was clearly natural or depleted. Urine uranium concentrations of soldiers with shrapnel were higher than those of the two other groups, and 16 out of 17 soldiers with shrapnel had detectable depleted uranium in their urine. In depleted uranium exposed soldiers with no shrapnel, depleted uranium was detected in urine samples of 10 out of 28 soldiers. The median uranium concentration of urines with depleted uranium from soldiers without shrapnel was significantly higher than in urines with no depleted uranium, though substantial overlap in urine uranium concentrations existed between the two groups. Accordingly, assessment of depleted uranium exposure using urine must rely on uranium isotopic analyses, since urine uranium concentration is not an unequivocal indicator of depleted uranium presence in soldiers with no

  20. Dynamic Assessment of Functional Lipidomic Analysis in Human Urine.

    PubMed

    Rockwell, Hannah E; Gao, Fei; Chen, Emily Y; McDaniel, Justice; Sarangarajan, Rangaprasad; Narain, Niven R; Kiebish, Michael A

    2016-07-01

    The development of enabling mass spectrometry platforms for the quantification of diverse lipid species in human urine is of paramount importance for understanding metabolic homeostasis in normal and pathophysiological conditions. Urine represents a non-invasive biofluid that can capture distinct differences in an individual's physiological status. However, currently there is a lack of quantitative workflows to engage in high throughput lipidomic analysis. This study describes the development of a MS/MS(ALL) shotgun lipidomic workflow and a micro liquid chromatography-high resolution tandem mass spectrometry (LC-MS/MS) workflow for urine structural and mediator lipid analysis, respectively. This workflow was deployed to understand biofluid sample handling and collection, extraction efficiency, and natural human variation over time. Utilization of 0.5 mL of urine for structural lipidomic analysis resulted in reproducible quantification of more than 600 lipid molecular species from over 20 lipid classes. Analysis of 1 mL of urine routinely quantified in excess of 55 mediator lipid metabolites comprised of octadecanoids, eicosanoids, and docosanoids generated by lipoxygenase, cyclooxygenase, and cytochrome P450 activities. In summary, the high-throughput functional lipidomics workflow described in this study demonstrates an impressive robustness and reproducibility that can be utilized for population health and precision medicine applications. PMID:27038173

  1. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    PubMed

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  2. A practical approach to using spot urine protein/creatinine ratios for assessing proteinuria in pregnancy

    PubMed Central

    Marnoch, Catherine A; Larson, Lucia; Weitzen, Sherry; Phipps, Maureen G; Sung, C James; Powrie, Raymond O

    2008-01-01

    Objective: The aim of this study is to assess the diagnostic accuracy of the spot urine protein/creatinine ratio compared with the 24-hour urine protein in pregnancy. Study Design: In this prospective cohort study of inpatient pregnant women, the protein/creatinine ratio and dipstick protein were assessed from a single urine sample collected at the start of the 24-hour urine. Both tests were compared with the 24-hour urine protein for correlation and test characteristics. Results: In the 196 specimens analysed, we found a strong correlation between the spot urine protein/creatinine ratio and 24-hour urine protein (r 2 = 0.78, P < 0.01). A protein/creatinine ratio <0.1 ruled out significant proteinuria (≥300 mg/day) with sensitivity and negative predictive value 100%. A protein/creatinine ratio ≥0.4 detected significant proteinuria (specificity and positive predictive value of 100%). A protein/creatinine ratio ≥4.6 had a specificity and positive predictive value of 100% for detecting severe proteinuria (≥5000 mg/day). Urine dipsticks correlated poorly with the 24-hour urine protein (r 2 = 0.40, P = 0.826). Nineteen percent of dipsticks reading nil or trace were false-negative results. Conclusion: The spot urine protein/creatinine ratio correlated well with the 24-hour urine protein and performed better than the urine dipsticks. Significant proteinuria in pregnancy was excluded if the protein/creatinine ratio was <0.1 and identified when it was ≥0.4.

  3. The Clinical Urine Culture: Enhanced Techniques Improve Detection of Clinically Relevant Microorganisms.

    PubMed

    Price, Travis K; Dune, Tanaka; Hilt, Evann E; Thomas-White, Krystal J; Kliethermes, Stephanie; Brincat, Cynthia; Brubaker, Linda; Wolfe, Alan J; Mueller, Elizabeth R; Schreckenberger, Paul C

    2016-05-01

    Enhanced quantitative urine culture (EQUC) detects live microorganisms in the vast majority of urine specimens reported as "no growth" by the standard urine culture protocol. Here, we evaluated an expanded set of EQUC conditions (expanded-spectrum EQUC) to identify an optimal version that provides a more complete description of uropathogens in women experiencing urinary tract infection (UTI)-like symptoms. One hundred fifty adult urogynecology patient-participants were characterized using a self-completed validated UTI symptom assessment (UTISA) questionnaire and asked "Do you feel you have a UTI?" Women responding negatively were recruited into the no-UTI cohort, while women responding affirmatively were recruited into the UTI cohort; the latter cohort was reassessed with the UTISA questionnaire 3 to 7 days later. Baseline catheterized urine samples were plated using both standard urine culture and expanded-spectrum EQUC protocols: standard urine culture inoculated at 1 μl onto 2 agars incubated aerobically; expanded-spectrum EQUC inoculated at three different volumes of urine onto 7 combinations of agars and environments. Compared to expanded-spectrum EQUC, standard urine culture missed 67% of uropathogens overall and 50% in participants with severe urinary symptoms. Thirty-six percent of participants with missed uropathogens reported no symptom resolution after treatment by standard urine culture results. Optimal detection of uropathogens could be achieved using the following: 100 μl of urine plated onto blood (blood agar plate [BAP]), colistin-nalidixic acid (CNA), and MacConkey agars in 5% CO2 for 48 h. This streamlined EQUC protocol achieved 84% uropathogen detection relative to 33% detection by standard urine culture. The streamlined EQUC protocol improves detection of uropathogens that are likely relevant for symptomatic women, giving clinicians the opportunity to receive additional information not currently reported using standard urine culture

  4. Analysis of goldenseal, Hydrastis canadensis L., and related alkaloids in urine using HPLC with UV detection.

    PubMed

    Dawes, Michelle L; Brettell, Thomas

    2012-01-01

    A screening method was developed to extract and detect berberine and hydrastine alkaloids from goldenseal root powder and urine samples using HPLC with UV detection. The isocratic method was developed to detect alkaloids in 5 mL of urine prior to drug screening. Urine samples were spiked with the alkaloids at varying concentrations and extracted twice with 3:1 chloroform:2-propanol (CHCl(3):2-propanol). The extracts were combined, concentrated using nitrogen gas and the residue was then reconstituted with a mobile phase of acetonitrile:buffer (32:68). A 17 min isocratic run time was performed with a flow rate of 2.0 mL/min, and UV detection at 230 nm using a C(18) (250 mm × 4.6 mm) column at room temperature. The method showed good linearity for berberine (r(2)=0.9990) and hydrastine (r(2)=0.9983) over a range of 11.80 ng/mL to 17.64 μg/mL. The LOD for berberine in urine was 12.74 ng/mL and the LOD for hydrastine in urine was 54.48 ng/mL. Urine samples were spiked with goldenseal root powder and liquid extract as part of a blinded study to determine whether berberine and hydrastine alkaloids could also be extracted in vitro from goldenseal and show a presence in urine samples. Out of the 37 blinded urine samples extracted the two spiked samples were correctly identified based on the presence or absence of berberine and hydrastine. The results demonstrated that this method will enable laboratories to test for the herbal supplement in submitted urine samples prior to drug testing, avoiding false negative results. PMID:22177787

  5. Urine Bag as a Modern Day Matula

    PubMed Central

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may give clue to presence of infections, medications, poisons, and hemolysis. Although worrisome to the patient, urine discoloration is mostly benign and resolves with removal of the offending agent. Twelve urine bags with discolored urine (and their predisposing causes) have been shown as examples. Urine colors (blue-green, yellow, orange, pink, red, brown, black, white, and purple) and their etiologies have been reviewed following a literature search in these databases: Pubmed, EBSCO, Science Direct, Proquest, Google Scholar, Springer, and Ovid. PMID:24959539

  6. Development of an In-line Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Branelle R.

    2009-01-01

    Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

  7. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  8. Effect of injected rotenone on the production and composition of urine from the rainbow trout (Salmo gairdneri)

    USGS Publications Warehouse

    Erickson, D.A.; Gingerich, W.H.

    1986-01-01

    Renal function was evaluated in adult rainbow trout (Salmo gairdneri) dosed i.a. with rotenone at 225 and 275 μg/kg. The chemical composition of urine samples and urine flow rates collected over a 5-h pretreatment period were compared with hourly urine samples collected over a 5-h posttreatment period. Significant increases in osmolality and in concentrations of sodium, potassium, chloride, glucose, and total protein were observed in the urine of treated fish. Urine solute concentrations reached maximum values within 1 to 3 h after treatment and decreased thereafter, indicating that the effects were reversible. Concentrations of sodium and chloride were highly correlated in 2-h posttreatment urine samples at the low (r = 0.922) and high (r = 0.981) rotenone treatments. Urine flow rates were reduced in trout at each dose of rotenone but the decrease in volume of urine voided was not dose-dependent. In a separate study, [14C]polyethylene glycol was used as a filtration marker to determine the effect of rotenone treatment (225 &mu:g/kg) on urine flow rate, glomerular filtration rate, and renal water reabsorption. We showed that posttreatment urine flow rates were reduced partly by reduced glomerular filtration and partly by increased water reabsorption. Transient increases in plasma osmolality and hematocrit also were observed 0.5 h after rotenone treatment.

  9. International Space Station Urine Monitoring System Functional Integration and Science Testing

    NASA Technical Reports Server (NTRS)

    Rodriquez, Branelle R.; Broyan, James Lee, Jr.

    2011-01-01

    Exposure to microgravity during human spaceflight needs to be better understood as the human exploration of space requires longer duration missions. It is known that long term exposure to microgravity causes bone loss. Measuring the calcium and other metabolic byproducts in a crew member s urine can evaluate the effectiveness of bone loss countermeasures. The International Space Station (ISS) Urine Monitoring System (UMS) is an automated urine collection device designed to collect urine, separate the urine and air, measure the void volume, and allow for syringe sampling. Accurate measuring and minimal cross-contamination is essential to determine bone loss and the effectiveness of countermeasures. The ISS UMS provides minimal cross-contamination (<0.7 mL urine) and has volume accuracy of 2% between 100 to 1000 mL urine voids. Designed to provide a non-invasive means to collect urine samples from crew members, the ISS UMS operates in-line with the Node 3 Waste and Hygiene Compartment (WHC). The ISS UMS has undergone modifications required to interface with the WHC, including material changes, science algorithm improvements, and software platform revisions. Integrated functional testing was performed to determine the pressure drop, air flow rate, and the maximum amount of fluid capable of being discharged from the UMS to the WHC. This paper will detail the results of the science and the functional integration tests.

  10. Comparison of a Validated LC/MS/MS Method with a Validated GC/MS Method for the Analysis of Zeranol and its Related Mycotoxin Residues in Bovine Urine Samples Collected During Argentina's Residue Monitoring Control Program (2005-2012).

    PubMed

    Echarte, Juan M; Fernández, Damián C; Chiacchio, Carlos A; Torres Leedham, Verónica M

    2014-01-01

    The use of zeranol (ZRL), a resorcylic acid lactone, in food animal production has been banned in Argentina since 2004. To enforce this regulation, a GC/MS method developed by the official laboratory was used to confirm ZRL, taleranol, and α- and β-zearalenol from suspect samples. A few years later, a more sensitive LC/MS/MS method was also developed for testing these four analytes plus zearalenone. Both methods were validated according to local standards that are equivalent to 657/2002/EC, and the GC/MS method was accredited under ISO/International Electrotechnical Commission 17025. This paper describes the analytical methods, compares their performances, and presents conclusions derived from their results. When these methods were used on national control plans in which about 1262 samples were analyzed annually over the 2005-2011 sampling period, the incidence rate for noncompliant samples analyzed by GC/MS ranged from 0.3 to 4%. Of the 1500 samples analyzed in 2012 by both methods, the noncompliance incidence rate was only 0.3%. PMID:25903002

  11. Is urine an alternative to cosmetically treated hair for the detection of drugs and alcohol?

    PubMed

    Agius, Ronald; Dufaux, Bertin; Kahl, Hans-Gerhard; Nadulski, Thomas

    2014-06-01

    This study attempts to assess the utility of the urine matrix as an alternative to cosmetically treated hair for the detection of drugs and alcohol for driving licence re-granting in 1026 cosmetically treated hair samples and 33 262 urine routine samples. No significant difference was observed between the percentage positive samples in cosmetically treated hair to those in urine at both the 95% and 99% significance level for amphetamines, cocaine, opiates, benzodiazepines, and methadone. Significant difference was found between the positivity rates of cannabinoids in cosmetically treated hair and that in urine indicating urine to be a better alternative to the use of the hair matrix even when cosmetically treated. The opposite was observed for the alcohol consumption marker ethyl glucuronide (EtG) for which the positivity rate in cosmetically treated hair was twice that in urine samples. Particularly for alcohol abstinence monitoring, as for the rehabilitative driving licence re-granting medical and psychological assessment (MPA) programme in Germany, it seems that ethyl glucuronide (EtG) in hair presents a much better alternative than urine testing, even when cosmetically treated hair is analyzed. Moreover, segmentation is an additional advantage of hair testing which can provide additional useful information. PMID:24817057

  12. "Varibaculum massiliense" sp. nov., a new bacterial species isolated from human urine.

    PubMed

    Brahimi, S E-H; Khelaifia, S; Raoult, D; Moal, V

    2016-09-01

    We report the main characteristics of "Varibaculum massiliense" strain Marseille-P2802(T) (=CSUR P2802), which was isolated from urine sample of a 59-year-old man with end-stage renal disease. PMID:27504187

  13. Long-term studies of urease-induced crystallization in human urine.

    PubMed

    Edin-Liljegren, A; Grenabo, L; Hedelin, H; Pettersson, S; Wang, Y H

    1994-07-01

    Urine samples were inoculated with viable Proteus mirabilis or purified Jack bean urease. The subsequent pH increase and crystallization were followed for 2 weeks. Particle formation was detected much earlier and at a lower pH in urines inoculated with Proteus, in which a higher end pH was also reached. The crystal configuration in bacteria and urease inoculated samples was different. Crystal aggregation was also much more pronounced in the Proteus mirabilis inoculated samples. The total precipitation was markedly increased in the Proteus mirabilis inoculated samples. The presence of live Proteus mirabilis thus has a profound influence on urease-induced crystallization in human urine. Despite the formation of rather large crystal aggregates in the Proteus-inoculated urines, no firm aggregates of a "prestone" type were observed. PMID:8201667

  14. Litomosoides sigmodontis: a jird urine metabolome study.

    PubMed

    Globisch, Daniel; Specht, Sabine; Pfarr, Kenneth M; Eubanks, Lisa M; Hoerauf, Achim; Janda, Kim D

    2015-12-15

    The neglected tropical disease onchocerciasis affects more than 35 million people worldwide with over 95% in Africa. Disease infection initiates from the filarial parasitic nematode Onchocerca volvulus, which is transmitted by the blackfly vector Simulium sp. carrying infectious L3 larvae. New treatments and diagnostics are required to eradicate this parasitic disease. Herein, we describe that a previously discovered biomarker for onchocerciasis, N-acetyltyramine-O-glucuronide (NATOG) is also present in urine samples of jirds infected with the onchocerciasis model nematode Litomosoides sigmodontis. Increased NATOG values paralleled a progressing infection and demonstrated that quantification of NATOG in this rodent model can be utilized to track its infectivity. Moreover, our findings suggest how NATOG monitoring may be used for evaluating potential drug candidates. PMID:26573416

  15. Direct colorimetric method for determination of organophosphates in human urine.

    PubMed

    Namera, A; Utsumi, Y; Yashiki, M; Ohtani, M; Imamura, T; Kojima, T

    2000-01-20

    A simple and sensitive method for determination of organophosphorus pesticides in human urine was developed by detecting the color complexes which resulted from reactions of organophosphorus pesticides and 4-(4-nitrobenzyl)pyridine (NBP) in urine. Based on studies of reaction conditions, e.g. reaction temperature and time, and reagent concentration, a colorimetric method was established. A 0.1-ml volume of NBP (45% in acetone) was added to a 1.0-ml volume of a urine sample, and the mixture was heated at 100 degrees C for 20 min. After cooling, 0.1 ml of tetraethylenepentamine was added. The organophosphorus pesticides showed a characteristic purplish blue color and the coloring complexes which were produced were stable for several hours. Furthermore, these complexes could be determined spectrophotometrically. The detection limits were 0.10-10 microg/ml in urine. The required time for analysis was approximately 30 min for one sample. Comparing the result of the proposed method with those of the GC-MS method, the results were similar for the 12 poisoning cases studied. Thus, the proposed method is useful for detection of these pesticides in critical care practices. PMID:10612713

  16. [Quantitative urine microscopic examination using disposable counting chamber for diagnosis of urinary tract infection].

    PubMed

    Hida, Y; Yamashita, M; Gejyo, F; Hiraoka, M; Hori, C; Sudo, M

    1995-12-01

    Routine urinalysis is performed as a screening test for urinary tract infection (UTI) in out-patients or in-patients. We assessed the usefulness of microscopic examination of unspun and unstained urine using a disposable slide with counting chambers (Kova Slide 10 grid, Miles-Sankyo) for diagnosis of significant bacteriuria. 173 fresh urine samples were obtained from 173 subjects (89 male and 84 (female), including 117 inpatients, aged from 0 to 96 years. Urine samples were examined for bacteriuria by the standard culture method and counting chamber method. Significant bacteriuria was defined as 10(5)/ml or more of bacilli for midstream urine and urine collected by bags and 10(4)/ml or more for urine collected by catheterization and from indwelling catheters. Urine leukocytes were also counted on disposable slide. The rapid dipstick test (N-multistix-SG-10, Miles-Sankyo) of leukocyte esterase activity and nitrite were measured in the urine specimens read by a photometer (Clinitek-10, Miles-Sankyo). Significant bacteriuria was diagnosed by standard culture method in 67 urine samples. Close correlation was obtained between bacterial counts determined by the bacterial culture and counting chamber method (Spearman's correlation coefficient p < 0.001). Sensitivity and negative predictive value for significant bacteriuria were 94.0 and 95.1%, respectively, when bacteriuria or pyuria was present in the counting chamber. Dipstick test had a sensitivity and negative predictive value of 86.6 and 89.9%, respectively, when either leukocyte esterase activity of + or more, or nitrite of + was found. In out-patients, both sensitivity and negative predictive value were as high as 100% in counting chamber method. Thus, we can conclude that urine microscopy on disposable counting chambers is a very sensitive, simple, time-saving and lost-effective method for diagnosis of UTI. PMID:8569040

  17. APPLICATION OF SAMPLE PRE-OXIDATION OF ARSENITE IN HUMAN URINE PRIOR TO SPECIATON VIA ON-LINE PHOTO-OXIDATION WITH MEMBRANE HYDRIDE GENRATION AND ICP-MS DETECTION

    EPA Science Inventory

    A pre-oxidation procedure which converts arsenite (AS(III)) to arsenate (As(VVV)) was investigated in urinary arsenic speciation prior to on-line photo-oxidation hydride-generation with ICP-MS detection. This sample pre-oxidation method eliminates As(III) and As(V) preservation c...

  18. Method comparison for 241Am emergency urine bioassay.

    PubMed

    Li, Chunsheng; Sadi, Baki; Benkhedda, Karima; St-Amant, Nadereh; Moodie, Gerry; Ko, Raymond; Dinardo, Anthony; Kramer, Gary

    2010-10-01

    241Am is one of the high-risk radionuclides that might be used in a terrorist attack. 241Am in urine bioassay can identify the contaminated individuals who need immediate medical intervention and decontamination. This paper compares three methods for the measurement of 241Am in urine, namely liquid scintillation counting (LSC), inductively coupled plasma mass spectrometry (ICP-MS) and gamma spectrometry (GS), at two levels, 20 and 2 Bq l(-1). All three methods satisfied the ANSI N13.30 radio-bioassay criteria for accuracy and repeatability. ICP-MS offered the best sensitivity and fastest sample turnaround; however, the ICP-MS system used in this work may not be available in many bioassay laboratories. LSC and GS are more commonly available instruments. GS requires minimal or no sample preparation, which makes it a good candidate method. Moreover, the sample throughput can be significantly improved if the GS and LSC methods are automated. PMID:20573683

  19. A history of urine microscopy.

    PubMed

    Cameron, J Stewart

    2015-11-01

    The naked-eye appearance of the urine must have been studied by shamans and healers since the Stone Age, and an elaborate interpretation of so-called Uroscopy began around 600 AD as a form of divination. A 1000 years later, the first primitive monocular and compound microscopes appeared in the Netherlands, and along with many other objects and liquids, urine was studied from around 1680 onwards as the enlightenment evolved. However, the crude early instruments did not permit fine study because of chromatic and linear/spherical blurring. Only after complex multi-glass lenses which avoided these problems had been made and used in the 1820s in London by Lister, and in Paris by Chevalier and Amici, could urinary microscopy become a practical, clinically useful tool in the 1830s. Clinical urinary microscopy was pioneered by Rayer and his pupils in Paris (especially Vigla), in the late 1830s, and spread to UK and Germany in the 1840s, with detailed descriptions and interpretations of cells and formed elements of the urinary sediment by Nasse, Henle, Robinson and Golding Bird. Classes were held, most notably by Donné in Paris. After another 50 years, optical microscopy had reached its apogee, with magnifications of over 1000 times obtainable free of aberration, using immersion techniques. Atlases of the urinary sediment were published in all major European countries and in the US. Polarised light and phase contrast was used also after 1900 to study urine, and by the early 20th century, photomicroscopy (pioneered by Donné and Daguerre 50 years previously, but then ignored) became usual for teaching and recording. In the 1940s electron microscopy began, followed by detection of specific proteins and cells using immunofluorescent antibodies. All this had been using handheld methodology. Around 1980, machine-assisted observations began, and have dominated progress since. PMID:26079823

  20. A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air-assisted liquid-liquid microextraction from human urine and plasma samples followed by gas chromatography-nitrogen phosphorous detection.

    PubMed

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. PMID:26014445

  1. Towards the Detection of Prostate Cancer in Urine: A Critical Analysis

    PubMed Central

    Truong, Matthew; Yang, Bing; Jarrard, David

    2013-01-01

    Introduction Prostate specific antigen (PSA) and digital rectal exam (DRE) have low specificity for the detection of prostate cancer (PCa) and poorly predict the presence of aggressive disease. Urine is readily available, non-invasive, and represents a promising source of biomarkers for early detection and prediction of PCa prognosis. The goal of this review is to identify promising biomarkers for urine-based PCa, examine trends, and outline potential pitfalls. Methods Pubmed® and Web of Science® database searches of peer-reviewed literature on urine-based testing in PCa were performed. Original studies on this subject, as well as a small number of reviews, were analyzed including the strengths and weaknesses. We provide a comprehensive review of urine-based testing for PCa that covers the technical aspects including the methodology of urine collection, as well as recent developments in biomarkers spanning the fields of genomics, epigenetics, transcriptomics, proteomics, and metabolomics. Results The process of urine collection is subject to variability, which may result in conflicting clinical results. Detecting PCa in urine is technically feasible as demonstrated by numerous “proof-of principle” studies, but few markers have been validated in multiple large sample sets. Biomarker development using urine has been accelerating in recent years, with numerous studies identifying DNA, RNA, protein, and metabolite-based biomarkers in the urine. Advanced clinical studies have identified PCA3 and TMPRSS2:ERG fusion transcripts as promising RNA markers for cancer detection and possibly prognosis. DNA methylation analysis of multiple genes improves specificity, and represents a promising platform for the development of clinical-grade assays. Conclusions Urine-based testing is non-invasive and represents a rich source of novel biomarkers for PCa. Although urine demonstrates promise in detecting cancer, the ability to identify aggressive subsets of PCa needs further

  2. Urine glucose analysis with functionalized graphene oxide as a material for amperometric sensor.

    PubMed

    Kim, Hye-youn; Jang, Kuk-Jin; Lee, Min-Ho

    2013-01-01

    New functionalized graphene oxide (FGO) was systematically coated on the fabricated Au-PCB for the detection of glucose in urine. The electrical response of FGO-Au-PCB exhibited a wide linearity of 1.7∼44.4 mM of glucose levels and a constant variables was less than 3% of the previously performed multiple measurements. The practical application has been demonstrated by measuring the electrical response against glucose in urine samples. In addition, our findings show similar improvement in urine glucose; within each current level, there were significant improvements in urine glucose. Comparison between the urine glucose and blood glucose showed no significant different level from the same subjects. PMID:24110736

  3. A Standardized and Reproducible Urine Preparation Protocol for Cancer Biomarkers Discovery

    PubMed Central

    Beretov, Julia; Wasinger, Valerie C; Schwartz, Peter; Graham, Peter H; Li, Yong

    2014-01-01

    A suitable and standardized protein purification technique is essential to maintain consistency and to allow data comparison between proteomic studies for urine biomarker discovery. Ultimately, efforts should be made to standardize urine preparation protocols. The aim of this study was to develop an optimal analytical protocol to achieve maximal protein yield and to ensure that this method was applicable to examine urine protein patterns that distinguish disease and disease-free states. In this pilot study, we compared seven different urine sample preparation methods to remove salts, and to precipitate and isolate urinary proteins. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) profiles showed that the sequential preparation of urinary proteins by combining acetone and trichloroacetic acid (TCA) alongside high speed centrifugation (HSC) provided the best separation, and retained the most urinary proteins. Therefore, this approach is the preferred method for all further urine protein analysis. PMID:25452700

  4. The Characterization of Feces and Urine: A Review of the Literature to Inform Advanced Treatment Technology

    PubMed Central

    Rose, C.; Parker, A.; Jefferson, B.; Cartmell, E.

    2015-01-01

    The safe disposal of human excreta is of paramount importance for the health and welfare of populations living in low income countries as well as the prevention of pollution to the surrounding environment. On-site sanitation (OSS) systems are the most numerous means of treating excreta in low income countries, these facilities aim at treating human waste at source and can provide a hygienic and affordable method of waste disposal. However, current OSS systems need improvement and require further research and development. Development of OSS facilities that treat excreta at, or close to, its source require knowledge of the waste stream entering the system. Data regarding the generation rate and the chemical and physical composition of fresh feces and urine was collected from the medical literature as well as the treatability sector. The data were summarized and statistical analysis was used to quantify the major factors that were a significant cause of variability. The impact of this data on biological processes, thermal processes, physical separators, and chemical processes was then assessed. Results showed that the median fecal wet mass production was 128 g/cap/day, with a median dry mass of 29 g/cap/day. Fecal output in healthy individuals was 1.20 defecations per 24 hr period and the main factor affecting fecal mass was the fiber intake of the population. Fecal wet mass values were increased by a factor of 2 in low income countries (high fiber intakes) in comparison to values found in high income countries (low fiber intakes). Feces had a median pH of 6.64 and were composed of 74.6% water. Bacterial biomass is the major component (25–54% of dry solids) of the organic fraction of the feces. Undigested carbohydrate, fiber, protein, and fat comprise the remainder and the amounts depend on diet and diarrhea prevalence in the population. The inorganic component of the feces is primarily undigested dietary elements that also depend on dietary supply. Median urine

  5. Quantitation of proteinuria in nephrotic syndrome by spot urine protein creatinine ratio estimation in children.

    PubMed

    Biswas, A; Kumar, R; Chaterjee, A; Ghosh, J K; Basu, K

    2009-01-01

    In Nephrotic Syndrome the amount of protein excretion is a reflection of activity of disease. Quantitative measurement of proteinuria by a 24-hour urine collection has been the accepted method of evaluation. Recent studies have shown that calculation of protein/creatinine ratio in a spot urine sample correlates well with the 24-hour urine protein (24-HUP) excretion. A study was conducted to compare the accuracy of a spot urinary protein/creatinine ratio (P/C ratio) and urinary dipstick with the 24-hour urine protein. Fifty two samples from 26 patients of nephrotic syndrome were collected. This included a 24-hour urine sample followed by the next voided random spot sample. The protein/creatinine ratio was calculated and dipstick was performed on the spot sample. This was compared with the 24-hour urine protein excretion. The correlation between the three samples was statistically highly significant (p<0.001) for all levels of proteinuria. The normal value of protein/creatinine ratio in Indian children was also estimated on 50 normal children admitted in the ward without any renal diseases calculated to be 0.053 (SE of mean+/-0.003). PMID:19182753

  6. Identification of HIV-1 Genitourinary Tract Compartmentalization by Analyzing the env Gene Sequences in Urine

    PubMed Central

    BLASI, Maria; CARPENTER, J. Harris; BALAKUMARAN, Bala; CARA, Andrea; GAO, Feng; KLOTMAN, Mary E.

    2015-01-01

    Objective HIV-1 persists indefinitely in memory CD4+ T cells and other long-lived cellular reservoirs despite antiretroviral therapy (ART). Our group had previously demonstrated that HIV-1 can establish a productive infection in renal epithelial cells and that the kidney represents a separate compartment for HIV-1 replication. Here, to better understand the viruses in this unique site, we genetically characterized and compared the viruses in blood and urine specimens from twenty-four HIV-1 infected subjects with detectable viremia. Design and Methods Blood and urine samples were obtained from 35 HIV-1 positive subjects. Single-genome amplification was performed on HIV-1 env RNA and DNA isolated from urine supernatants and urine derived cell pellets respectively, as well as from plasma and PBMC from the same individuals. Neighbor-joining trees were constructed under the Kimura 2-parameter mode. Results We amplified and sequenced the full-length HIV-1 envelope (env) gene from twelve of the twenty-four individuals, indicating that fifty percent (50%) of the viremic HIV-1 positive patients had viral RNA in their urine. Phylogenetic analysis of the env sequences from four subjects with more than fifteen urine-derived env sequences showed that the majority of the sequences from urine formed distinct cluster(s) independent of those PBMC and plasma-derived sequences, consistent with viral compartmentalization in the urine. Conclusions Our results suggest the presence of a distinct HIV compartment in the genitourinary tract. PMID:26372275

  7. Effect of source-separated urine storage on estrogenic activity detected using bioluminescent yeast Saccharomyces cerevisiae.

    PubMed

    Jaatinen, Sanna; Kivistö, Anniina; Palmroth, Marja R T; Karp, Matti

    2016-09-01

    The objective was to demonstrate that a microbial whole cell biosensor, bioluminescent yeast, Saccharomyces cerevisiae (BMAEREluc/ERα) can be applied to detect overall estrogenic activity from fresh and stored human urine. The use of source-separated urine in agriculture removes a human originated estrogen source from wastewater influents, subsequently enabling nutrient recycling. Estrogenic activity in urine should be diminished prior to urine usage in agriculture in order to prevent its migration to soil. A storage period of 6 months is required for hygienic reasons; therefore, estrogenic activity monitoring is of interest. The method measured cumulative female hormone-like activity. Calibration curves were prepared for estrone, 17β-estradiol, 17α- ethinylestradiol and estriol. Estrogen concentrations of 0.29-29,640 μg L(-1) were detectable while limit of detection corresponded to 0.28-35 μg L(-1) of estrogens. The yeast sensor responded well to fresh and stored urine and gave high signals corresponding to 0.38-3,804 μg L(-1) of estrogens in different urine samples. Estrogenic activity decreased during storage, but was still higher than in fresh urine implying insufficient storage length. The biosensor was suitable for monitoring hormonal activity in urine and can be used in screening anthropogenic estrogen-like compounds interacting with the receptor. PMID:26804108

  8. Assessment of serum and urine ghrelin levels in patients with acute stroke

    PubMed Central

    Seyhanli, Eyyup Sabri; Lok, Ugur; Gulacti, Umut; Buyukaslan, Hasan; Atescelik, Metin; Yildiz, Mustafa; Onur, Mehmet Ruhi; Goktekin, Mehmet Cagri; Aydın, Suleyman

    2015-01-01

    Introduction: Ghrelin is a novel brain-gut peptide hormone consisted of 28 amino-acid. In the plasma, it exists in two major molecular forms, acylated and des-acyled ghrelin, filtered in glomeruli or secreted by nephrons. Primary biological effects of hormones are regulating appetite, foods intake and energy metabolism. We investigated the changing and relationships between serum and urine ghrelin levels in acute stroke patients to provide more information whether diagnostic parameter. Methods: Thirty acute stroke patients and thirty consecutive volunteers included in study prospectively. To analyze serum and urine ghrelin levels, at the time of diagnose, all of participant blood and fresh urine (1 ml serum, 2 ml urine respectively) samples were obtained. Serum ghrelin levels analyzed ELISA technique, and urine ghrelin levels studied by validation technique. To compare quantitative data student’s t test, and for qualitative data chi-square and Fisher’s Exact Chi-square test was used. P<0.05 was considered statistically significant. Results: Urine acyl ghrelin levels found statistically significant between patient and control groups (P=0.001), but there were no statistically significant differences between both groups (P>0.05) in serum acyl gherelin, des-acyl ghrelin and urine des-acyle ghrelin levels. Conclusions: The results indicate that urine acyl ghrelin levels may be considered as a diagnostic parameter in acute ischemic stroke patients. Further studies delineating the mechanism of these observed results are warranted. PMID:25785049

  9. Determination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise.

    PubMed

    Ough, E A; Lewis, B J; Andrews, W S; Bennett, L G I; Hancock, R G V; D'Agastino, P A

    2006-05-01

    An analytical exercise was initiated in order to determine those procedures with the capability to measure total uranium and uranium (238U/235U) isotopic ratios in urine samples containing >0.02 microg U kg-1 urine. A host laboratory prepared six identical sets of twelve synthetic urine samples containing total uranium in the range of 25 to 770 ng U kg-1 urine and with 238U/235U isotopic ratios ranging from 138 (100% NU) to 215 (51% DU). Sets of samples were shipped to five testing laboratories (four based in Canada and one based in Europe). Each laboratory utilized one of the following analytical techniques: sector field inductively coupled plasma mass spectrometry (ICP-SF-MS), quadrupole inductively coupled plasma mass spectrometry (ICP-Q-MS), thermal ionization mass spectrometry (TIMS), and instrumental/delayed neutron activation analysis (I/DNAA), in their analyses. PMID:16607181

  10. Relative density of urine: methods and clinical significance.

    PubMed

    Pradella, M; Dorizzi, R M; Rigolin, F

    1988-01-01

    The physical properties and chemical composition of urine are highly variable and are determined in large measure by the quantity and the type of food consumed. The specific gravity is the ratio of the density to that of water, and it is dependent on the number and weight of solute particles and on the temperature of the sample. The weight of solute particles is constituted mainly of urea (73%), chloride (5.4%), sodium (5.1%), potassium (2.4%), phosphate (2.0%), uric acid (1.7%), and sulfate (1.3%). Nevertheless, urine osmolality depends only on the number of solute particles. The renal production of maximally concentrated urine and formation of dilute urine may be reduced to two basic elements: (1) generation and maintenance of a renal medullary solute concentration hypertonic to plasma and (2) a mechanism for osmotic equilibration between the inner medulla and the collecting duct fluid. The interaction of the renal medullary countercurrent system, circulating levels of antidiuretic hormone, and thirst regulates water metabolism. Renin, aldosterone, prostaglandins, and kinins also play a role. Clinical estimation of the concentrating and diluting capacity can be performed by relatively simple provocative tests. However, urinary specific gravity after taking no fluids for 12 h overnight should be 1.025 or more, so that the second urine in the morning is a useful sample for screening purposes. Many preservation procedures affect specific gravity measurements. The concentration of solids (or water) in urine can be measured by weighing, hydrometer, refractometry, surface tension, osmolality, a reagent strip, or oscillations of a capillary tube. These measurements are interrelated, not identical. Urinary density measurement is useful to assess the disorders of water balance and to discriminate between prerenal azotemia and acute tubular necrosis. The water balance regulates the serum sodium concentration, therefore disorders are revealed by hypo- and hypernatremia. The

  11. Sheath flow SERS for chemical profiling in urine.

    PubMed

    Riordan, Colleen M; Jacobs, Kevin T; Negri, Pierre; Schultz, Zachary D

    2016-06-23

    The molecular specificity and sensitivity of surface enhanced Raman scattering (SERS) makes it an attractive method for biomedical diagnostics. Here we present results demonstrating the utility and complications for SERS characterization in urine. The chemical fingerprint characteristics of Raman spectra suggest its use as a label free diagnostic; however, the complex composition of biological fluids presents a tremendous challenge. In particular, the limited number of surface sites and competing absorption tend to mask the presence of analytes in solution, particularly when the solution contains multiple analytes. To address these problems and characterize biological fluids we have demonstrated a sheath-flow interface for SERS detection. This sheath-flow SERS interface uses hydrodynamic focusing to confine analyte molecules eluting out of a column onto a planar SERS substrate where the molecules are detected by their intrinsic SERS signal. In this report we compare the direct detection of benzoylecgonine in urine using DSERS with chemical profiling by capillary zone electrophoresis and sheath-flow SERS detection. The SERS spectrum from the observed migration peaks can identify benzoylecgonine and other distinct spectra are also observed, suggesting improved chemical diagnostics in urine. With over 2000 reported compounds in urine, identification of each of the detected species is an enormous task. Nonetheless, these samples provide a benchmark to establish the potential clinical utility of sheath-flow SERS detection. PMID:27034996

  12. Determination of monomethylarsonous acid, a key arsenic methylation intermediate, in human urine.

    PubMed Central

    Le, X C; Ma, M; Cullen, W R; Aposhian, H V; Lu, X; Zheng, B

    2000-01-01

    In this study we report on the finding of monomethylarsonous acid [MMA(III)] in human urine. This newly identified arsenic species is a key intermediate in the metabolic pathway of arsenic biomethylation, which involves stepwise reduction of pentavalent to trivalent arsenic species followed by oxidative addition of a methyl group. Arsenic speciation was carried out using ion-pair chromatographic separation of arsenic compounds with hydride generation atomic fluorescence spectrometry detection. Speciation of the inorganic arsenite [As(III)], inorganic arsenate [As(V)], monomethylarsonic acid [MMA(V)], dimethylarsinic acid [DMA(V)], and MMA(III) in a urine sample was complete in 5 min. Urine samples collected from humans before and after a single oral administration of 300 mg sodium 2,3-dimercapto-1-propane sulfonate (DMPS) were analyzed for arsenic species. MMA(III) was found in 51 out of 123 urine samples collected from 41 people in inner Mongolia 0-6 hr after the administration of DMPS. MMA(III )in urine samples did not arise from the reduction of MMA(V) by DMPS. DMPS probably assisted the release of MMA(III) that was formed in the body. Along with the presence of MMA(III), there was an increase in the relative concentration of MMA(V) and a decrease in DMA(V) in the urine samples collected after the DMPS ingestion. PMID:11102289

  13. The importance of acid digestion of urine prior to spontaneous deposition of 210Po.

    PubMed

    Fellman, A; Ralston, L; Hickman, D; Ayres, L; Cohen, N; Spitz, H; Robinson, B

    1989-10-01

    Historically, radiochemical analysis of 210Po in urine has used spontaneous deposition of the nuclide directly from raw urine onto a suitable metal disc. Consequently, the urinary excretion fraction for Po in some current metabolic and dosimetric models is based on studies which inherently assume that metabolized (i.e., filtered out of the blood by the kidneys) 210Po is plated with the same efficiency as tracer 210Po which has been added to urine samples. Urine samples collected after intravenous administration of 210Po citrate to two species of nonhuman primates were divided and simultaneously analyzed via two methods: the historical procedure of plating 210Po from raw urine for one sample and a method which includes the addition of 208Po tracer and sample digestion with concentrated HNO3 prior to 210Po deposition for the other sample. A more significant amount of 210Po was consistently recovered when the urine was wet ashed then when it was not wet ashed. A temporal relationship was found to describe the change in the ratio of the deposition recoveries for the two methods. Possible mechanisms for this phenomenon and its dosimetric implications are discussed. PMID:2507478

  14. Biological monitoring of nitroglycerin exposure by urine analysis.

    PubMed

    Akrill, Peter; Guiver, Robert; Cocker, John

    2002-08-01

    Historically biological monitoring to assess exposure has been difficult due to the rapid half-life of NG. However, the recent development of a method to assess NG and its metabolites (glycerol dinitrates, GDNs) in urine has made biological monitoring more feasible. The data reported here result from samples taken from three sites using NG. Two of the sites are munitions manufacturing sites and the other site is a pharmaceutical manufacturing site. The range of urinary GDN concentrations found in the samples at the two munitions sites were 0.9-18, and 0-4.7 micromol/mol creatinine, and at the pharmaceutical site were 0-0.9 micromol/mol creatinine). The presence of nitroglycols in the urine of workers despite the use of personal protective equipment and local exhaust ventilation shows the usefulness of biological monitoring to assess the efficacy of any controls in place and the potential of dermal absorption of NG. PMID:12191888

  15. [Elimination of N,N-dimethyltryptamine by urine].

    PubMed

    Spatz, N; Spatz, H; Mesones Arroyo, H L; Rosan, T; Brengio, F

    1993-09-01

    N,N-dimethiltryptamine (DMT) in urine has been quantified on an 83-psychiatric patient sample. Sample covered patients who had sometimes been administered neuroleptic drugs as well as patients with some particular symptomatology associated to psychotic disorders such as hallucinations, delusions, perception disorders, etc. 43.3% (36 cases) evidenced an abnormally high DMT in urine (0.9-13.5 mcg/24 h). Higher values were more frequently found in both schizophrenic patients, and non-schizophrenic patients with either hallucinations, delusions, anorexia or bulimia. Most patients with DMT normal values (< 0.5 mcg/24 h) presented either mental retardation, cerebral atrophy or dysrhythmias. A very good correlation was found between urinary DMT abnormally high values, and patients' improvement after such patients had been treated with neuroleptic drugs. PMID:7905222

  16. Difference in 24-Hour Urine Composition between Diabetic and Non-Diabetic Adults without Nephrolithiasis

    PubMed Central

    Qin, Jing; Duan, Xiaolu; Liu, Yang; Zhao, Zhijian; Yuan, Jian; Wan, Shaw P.; Zeng, Guohua

    2016-01-01

    Background Diabetic patients are more likely to develop kidney stones than the general population. The underlying mechanisms for this disparity remain to be elucidated. Little is known about the relationship between urine composition and diabetes mellitus in non-stone-forming individuals. We sought to examine the differences in the 24-hour (24-h) urine composition between diabetic and non-diabetic adults who were not stone formers. Methods A convenience sample of 538 individuals without a history of nephrolithiasis, gout, hyperparathyroidism, or gastroenteric diseases participated in this study. The 24-h urine profiles of 115 diabetic adults were compared with those of 423 non-diabetic adults. Diabetes was defined by self-reported physician diagnosis or medication use. All participants were non-stone formers confirmed by urinary tract ultrasonography. Participants provided a fasting blood sample and a single 24-h urine collection for stone risk analysis. Student’s t-test was used to compare mean urinary values. Linear regression models were adjusted for age, gender, body mass index, hypertension, fasting serum glucose, serum total cholesterol, estimated creatinine clearance rate and urinary factors. Results Univariable analysis showed that the diabetic participants had significantly higher 24-h urine volumes and lower urine calcium and magnesium excretions than non-diabetic participants (all P < 0.05). After multivariate adjustment, no significant differences in 24-h urine composition were observed between diabetic and non-diabetic participants except for a slightly increased 24-h urine volume in diabetic participants (all P > 0.05). The main limitation of this study is that the convenience samples and self-reported data may have been sources of bias. Conclusion Our data showed that there were no differences in 24-h urine composition between diabetic and non-diabetic adults who are not stone formers. The reason for it might be the improved glycemic control in

  17. Simultaneous detection of morphine and codeine in urine samples of heroin addicts using multi-walled carbon nanotubes modified SnO2-Zn2SnO4 nanocomposites paste electrode

    NASA Astrophysics Data System (ADS)

    Taei, M.; Hasanpour, F.; Hajhashemi, V.; Movahedi, M.; Baghlani, H.

    2016-02-01

    The SnO2-Zn2SnO4 nanocomposite was successfully prepared via a simple solid state method. Then, a chemically modified electrode based on incorporating SnO2-Zn2SnO4 into multi-walled carbon nanotube paste matrix (MWCNTs/SnO2-Zn2SnO4/CPE) was prepared for the simultaneous determination of morphine(MO) and codeine (CO). The measurements were carried out by application of differential pulse voltammetry (DPV), cyclic voltammetry, and chronoamperometry. The MWCNTs/SnO2-Zn2SnO4/CPE showed an efficient electrocatalytic activity for the oxidation of MO and CO. The separation of the oxidation peak potential for MO-CO was about 550 mV. The calibration curves obtained for MO and CO were in the ranges of 0.1-310 μmol L-1 and 0.1-600.0 μmol L-1, respectively. The detection limits (S/N = 3) were 0.009 μmol L-1 for both drugs. The method also successfully employed as a selective, simple, and precise method for the determination of MO and CO in pharmaceutical and biological samples.

  18. Hydroxylated collagen peptide in urine as biomarker for detecting colorectal liver metastases

    PubMed Central

    Lalmahomed, Zarina S; Bröker, Mirelle EE; van Huizen, Nick A; van den Braak, Robert RJ Coebergh; Dekker, Lennard JM; Rizopoulos, Dimitris; Verhoef, Cornelis; Steyerberg, Ewout W; Luider, Theo M; IJzermans, Jan NM

    2016-01-01

    The clinical efficacy of carcinoembryonic antigen (CEA) as a marker of colorectal liver metastasis is limited, motivating a search for new biomarkers. Recently, urine proteomic analysis revealed AGPP(-OH)GEAGKP(-OH)GEQGVP(-OH)GDLGAP(-OH)GP (AGP), a promising peptide for this application. This study aimed to determine whether combining urine AGP testing with serum CEA analyses improves the sensitivity of detecting colorectal liver metastases. Urine samples from 100 patients with CRLM were collected prospectively and compared to three control groups: healthy kidney donors, patients who were relapse-free for 24 months after curative CRLM surgery, and primary colorectal cancer patients. A stable isotope labeled peptide standard was used to quantify the abundance of AGP in urine samples by selective reaction monitoring. Combined testing of urine AGP levels and serum CEA levels revealed a significantly increased sensitivity compared to CEA alone (85% vs. 68%, P<0.001; specificity 84% and 91%, respectively). No correlation was found between CEA and AGP-positive test results within individual patients (r2 = 0.08). Urine AGP testing was negative in the three control groups. These results indicate that collagen-derived urine AGP peptide with a specific hydroxylation pattern combined with serum CEA levels may significantly improve the detection of colorectal liver metastases in patients at risk. PMID:27186406

  19. CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD.

    PubMed

    Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J

    2016-01-01

    Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine. PMID:27180423

  20. The void in using urine concentration to assess population fluid intake adequacy or hydration status.

    PubMed

    Cheuvront, Samuel N; Muñoz, Colleen X; Kenefick, Robert W

    2016-09-01

    Urine concentration can be used to assess fluid intake adequacy or to diagnose dehydration. However, too often urine concentration is used inappropriately to draw dubious conclusions that could have harmful health and economic consequences. Inappropriate uses of urine concentration relate primarily to convenience sampling (timing) and problems related to convenience sampling (misapplication of thresholds), but a conceptual problem also exists with using urine concentration in isolation. The purpose of this Perspective article is to briefly explain the problematic nature of current practices and to offer a possible solution to improve practice with minimal added complication. When urine is used exclusively to assess fluid intake adequacy and hydration status in adults, we propose that only when urine concentration is high (>850 mmol/kg) and urine excretion rate is low (<850 mL/24 h) should suspicion of inadequate drinking or impending dehydration be considered. Prospective tests of the 850 × 850 thresholds will provide supporting evidence and/or help refine the best thresholds for men and women, young and old. PMID:27465376