Science.gov

Sample records for 2g hts tapes

  1. Method for Determining Local Current Density in 2G HTS Tapes

    NASA Astrophysics Data System (ADS)

    Bludova, A. I.

    Practically important problem is to determine the density and direction of 2G HTS induced currents at each point on the tape in order to examine its local deviations. This problem is resolved indirectly by spatial measurement of generated magnetic field with a scanning Hall sensor at a given height above the tape surface. Current density is subsequently determined by the Biot-Savart law inversion in Fourier domain. Tikhonov regularization is used in order to increase precision. Method is verified with the model current density reconstruction. Optimal calculation parameters and resulting precision are described.

  2. Enhanced quench propagation in 2G-HTS coils co-wound with stainless steel or anodised aluminium tapes

    NASA Astrophysics Data System (ADS)

    Núñez-Chico, A. B.; Martínez, E.; Angurel, L. A.; Navarro, R.

    2016-08-01

    Early quench detection and thermal stability of superconducting coils are of great relevance for practical applications. Magnets made with second generation high temperature superconducting (2G-HTS) tapes present low quench propagation velocities and therefore slow voltage development and high local temperature rises, which may cause irreversible damage. Since quench propagation depends on the anisotropy of the thermal conductivity, this may be used to achieve an improvement of the thermal stability and robustness of 2G-HTS coils. On pancake type coils, the thermal conductivity along the tapes (coil’s azimuthal direction) is mostly fixed by the 2G-HTS tape characteristics, so that the reduction of anisotropy relies on the improvement of the radial thermal conductivity, which depends on the used materials between superconducting tapes, as well as on the winding and impregnation processes. In this contribution, we have explored two possibilities for such anisotropy reduction: by using anodised aluminium or stainless steel tapes co-wound with the 2G-HTS tapes. For all the analysed coils, critical current distribution, minimum quench energy values and both tangential and radial quench propagation velocities at different temperatures and currents are reported and compared with the results of similar coils co-wound with polyimide (Kapton®) tapes.

  3. Feasibility of a short-period superconducting undulator using 2G HTS tapes.

    SciTech Connect

    Kim, S. H.; Doose, C. L.; Jaski, M. S.; Kasa, M. T. )

    2011-06-01

    This paper presents a design concept of a planar-type superconducting undulator (SCU) using YBCO high-temperature superconductor (HTS) tapes. The SCU has a period length of 15 mm, and the tape conductor has dimensions of 4-mm width and 0.1-mm thickness. It has been shown that the conductor transition from one coil groove to the one in the next period is possible by making a semi-circular concave loop of the tape for continuous winding in the same direction. Non-uniform current distribution in the tape may cause field quality degradation. Assuming a uniform current density in the tape, the engineering critical-current density of the HTS in the coil for the design and the corresponding achievable on-axis peak field at 4.2 K were calculated.

  4. Synchronous motor with HTS-2G wires

    NASA Astrophysics Data System (ADS)

    Dezhin, D.; Ilyasov, R.; Kozub, S.; Kovalev, K.; Verzhbitsky, L.

    2014-05-01

    One of the applications of new high-temperature superconductor materials (HTS) is field coils for synchronous electrical machines. The use of YBCO 2G HTS tapes (HTS-2G) allows increasing of magnetic flux density in the air gap, which will increase the output power and reduce the dimensions of the motor. Such motors with improved characteristics can be successfully used in transportation as traction motor. In MAI-based "Center of Superconducting machines and devices" with the support of "Rosatom" has been designed and tested a prototype of the 50 kW synchronous motor with radial magnetic flux from a field-coils based on HTS-2G tapes. The experimental and theoretical results are presented.

  5. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  6. Total AC loss study of 2G HTS coils for fully HTS machine applications

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Yuan, Weijia; Kvitkovic, Jozef; Pamidi, Sastry

    2015-11-01

    The application of HTS coils for fully HTS machines has become a new research focus. In the stator of an electrical machine, HTS coils are subjected to a combination of an AC applied current and AC external magnetic field. There is a phase shift between the AC current and AC magnetic field. In order to understand and estimate the total AC loss of HTS coils for electrical machines, we designed and performed a calorimetric measurement for a 2G HTS racetrack coil. Our measurement indicates that the total AC loss is greatly influenced by the phase shift between the applied current and the external magnetic field when the magnetic field is perpendicular to the tape surface. When the applied current and the external magnetic field are in phase, the total AC loss is the highest. When there is a 90 degree phase difference, the total AC loss is the lowest. In order to explain this phenomenon, we employ H formulation and finite element method to model the 2G HTS racetrack coil. Our calculation agrees well with experimental measurements. Two parameters are defined to describe the modulation of the total AC loss in terms of phase difference. The calculation further reveals that the influence of phase difference varies with magnetic field direction. The greatest influence of phase difference is in the perpendicular direction. The study provides key information for large-scale 2G HTS applications, e.g. fully HTS machines and superconducting magnetic energy storage, where the total AC loss subjected to both applied currents and external magnetic fields is a critical parameter for the design.

  7. Synchronous Generator with HTS-2G field coils for Windmills with output power 1 MW

    NASA Astrophysics Data System (ADS)

    Kovalev, K.; Kovalev, L.; Poltavets, V.; Samsonovich, S.; Ilyasov, R.; Levin, A.; Surin, M.

    2014-05-01

    Nowadays synchronous generators for wind-mills are developed worldwide. The cost of the generator is determined by its size and weight. In this deal the implementation of HTS-2G generators is very perspective. The application of HTS 2G field coils in the rotor allows to reduce the size of the generator is 1.75 times. In this work the design 1 MW HTS-2G generator is considered. The designed 1 MW HTS-2G generator has the following parameters: rotor diameter 800 mm, active length 400 mm, phase voltage 690V, rotor speed 600 min-1 rotor field coils with HTS-2G tapes. HTS-2G field coils located in the rotating cryostat and cooled by liquid nitrogen. The simulation and optimization of HTS-2G field coils geometry allowed to increase feed DC current up to 50A. Copper stator windings are water cooled. Magnetic and electrical losses in 1 MW HTS-2G generator do not exceed 1.6% of the nominal output power. In the construction of HTS-2G generator the wave multiplier with ratio 1:40 is used. The latter allows to reduce the total mass of HTS-2G generator down to 1.5 tons. The small-scale model of HTS-2G generator with output power 50 kW was designed, manufactured and tested. The test results showed good agreement with calculation results. The manufacturing of 1 MW HTS-2G generator is planned in 2014. This work is done under support of Rosatom within the frames of Russian Project "Superconducting Industry".

  8. A study on the required performance of a 2G HTS wire for HTS wind power generators

    NASA Astrophysics Data System (ADS)

    Sung, Hae-Jin; Park, Minwon; Go, Byeong-Soo; Yu, In-Keun

    2016-05-01

    YBCO or REBCO coated conductor (2G) materials are developed for their superior performance at high magnetic field and temperature. Power system applications based on high temperature superconducting (HTS) 2G wire technology are attracting attention, including large-scale wind power generators. In particular, to solve problems associated with the foundations and mechanical structure of offshore wind turbines, due to the large diameter and heavy weight of the generator, an HTS generator is suggested as one of the key technologies. Many researchers have tried to develop feasible large-scale HTS wind power generator technologies. In this paper, a study on the required performance of a 2G HTS wire for large-scale wind power generators is discussed. A 12 MW class large-scale wind turbine and an HTS generator are designed using 2G HTS wire. The total length of the 2G HTS wire for the 12 MW HTS generator is estimated, and the essential prerequisites of the 2G HTS wire based generator are described. The magnetic field distributions of a pole module are illustrated, and the mechanical stress and strain of the pole module are analysed. Finally, a reasonable price for 2G HTS wire for commercialization of the HTS generator is suggested, reflecting the results of electromagnetic and mechanical analyses of the generator.

  9. Noncontacting ultrasonic and electromagnetic HTS tape NDE

    SciTech Connect

    Telschow, K.L.; Bruneel, F.W.; Walter, J.B.; Koo, L.S.

    1996-10-01

    Two noncontacting nondestructive evaluation techniques (electromagnetic and ultrasonic) for inspection of high temperature superconducting tapes are described. Results for Ag-clad BSCCO tapes are given.

  10. Torsion Strain Effects on Critical Currents of Hts Superconducting Tapes

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Minervini, Joseph V.; Bromberg, Leslie

    2010-04-01

    A torsional twist strain effect on the critical current of a thin HTS tape has been found to be well described by a longitudinal strain model taking into account the internal shortening compressive strains accompanied with the tensile longitudinal strains due to a torsional twist. The critical current of a twisted tape is given by the integration of the critical current densities corresponding to the strain distribution over the tape cross-section using axial strain data of the tape. The model is supported with experimental results of YBCO and BSCCO-2223 tapes. It has been also found that torsional twisting effects on the critical currents of a tape composing of the conventional lapped-tape cable and the twisted stacked-tape cable are described by the same equation as that of a twisted single tape.

  11. Test and Analysis of Spliced DI-BSCCO HTS Tapes

    NASA Astrophysics Data System (ADS)

    Fetisov, S. S.; Sotnikov, D. V.; Radchenko, I. P.; Vysotsky, V. S.; Osabe, G.; Kinoshita, K.; Fujikami, J.; Kobayashi, S.; Yamazaki, K.

    For some applications, short unit lengths of HTS wires should be spliced if longer lengths are necessary and short unit lengths of HTS wires should be utilize by applying the splice technology to reduce the total wire cost in the application. The splice technology has been developed for DI-BSCCO Type HT-CA tapes by Sumitomo Electric and spliced tapes were tested in Russian Cable Institute. The test program included: measurements of splice's resistance, critical current anisotropy, thermo cycling tolerance, mechanical properties, overload tests and magnetization measurements. In the paper the results of tests are presented and discussed. The test results demonstrated that splices can be used for cable production if twisting and bending limitations are taken into account.

  12. Theory of AC Loss in Cables with 2G HTS Wire

    SciTech Connect

    Clem, J.R.; Malozemoff, A.P.

    2009-09-13

    While considerable work has been done to understand AC losses in power cables made of first generation (1G) high temperature superconductor (HTS) wires, use of second generation (2G) HTS wires brings in some new considerations. The high critical current density of the HTS layer 2G wire reduces the surface superconductor hysteretic losses. Instead, gap and polygonal losses, flux transfer losses in imbalanced two layer cables and ferromagnetic losses for wires with NiW substrates constitute the principal contributions. Current imbalance and losses associated with the magnetic substrate can be minimized by orienting the substrates of the inner winding inward and the outer winding outward.

  13. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    NASA Astrophysics Data System (ADS)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  14. 2G HTS wires made on 30 μm thick Hastelloy substrate

    NASA Astrophysics Data System (ADS)

    Sundaram, A.; Zhang, Y.; Knoll, A. R.; Abraimov, D.; Brownsey, P.; Kasahara, M.; Carota, G. M.; Nakasaki, R.; Cameron, J. B.; Schwab, G.; Hope, L. V.; Schmidt, R. M.; Kuraseko, H.; Fukushima, T.; Hazelton, D. W.

    2016-10-01

    REBCO (RE = rare earth) based high temperature superconducting (HTS) wires are now being utilized for the development of electric and electromagnetic devices for various industrial, scientific and medical applications. In the last several years, the increasing efforts in using the so-called second generation (2G) HTS wires for some of the applications require a further increase in their engineering current density (J e). The applications are those typically related to high magnetic fields where the higher J e of a REBCO wire, in addition to its higher irreversibility fields and higher mechanical strength, is already a major advantage over other superconducting wires. An effective way to increase the J e is to decrease the total thickness of a wire, for which using a thinner substrate becomes an obvious and attractive approach. By using our IBAD-MOCVD (ion beam assisted deposition-metal organic chemical vapor deposition) technology we have successfully made 2G HTS wires using a Hastelloy® C276 substrate that is only 30 μm in thickness. By using this thinner substrate instead of the typical 50 μm thick substrate and with a same critical current (I c), the J e of a wire can be increased by 30% to 45% depending on the copper stabilizer thickness. In this paper, we report the fabrication and characterization of the 2G HTS wires made on the 30 μm thick Hastelloy® C276 substrate. It was shown that with the optimization in the processing protocol, the surface of the thinner Hastelloy® C276 substrate can be readily electropolished to the quality needed for the deposition of the buffer stack. Same in the architecture as that on the standard 50 μm thick substrate, the buffer stack made on the 30 μm thick substrate showed an in-plane texture with a Δϕ of around 6.7° in the LaMnO3 cap layer. Low-temperature in-field transport measurement results suggest that the wires on the thinner substrate had achieved equivalent superconducting performance, most importantly the I

  15. Design, fabrication and testing of a dipole magnet made with 2G HTS wire

    NASA Astrophysics Data System (ADS)

    Bogdanov, I. V.; Kozub, S. S.; Sytnik, V. V.; Terskiy, I. S.; Tkachenko, L. M.; Trusov, O. V.; Shirshov, L. S.; Smirnov, V. M.; Shuvalov, V. I.; Shcherbakov, P. A.; Molodyk, A. A.; Lee, S. R.; Samoilenkov, S. V.

    2016-10-01

    An HTS dipole magnet with a 1 T (at 77 K) central magnetic field in a 40 × 80 mm2 aperture has been designed, fabricated and tested. The magnet coils were wound with SuperOx 2G HTS wire. The paper describes the magnet design, properties of the magnet materials, and results of calculations and measurements. The central field in the dipole reached 1.12 T at 77 K and 1.66 T at 65 K. In a liquid helium bath the maximum input current of 847 A was limited by the capacity of the power supply, and in that case the central field was 3.03 T. The measurement data were in good agreement with the calculation results.

  16. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    NASA Astrophysics Data System (ADS)

    Oomen, Marijn; Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea

    2012-11-01

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  17. Multi-scale model of resistive-type superconducting fault current limiters based on 2G HTS coated conductors

    NASA Astrophysics Data System (ADS)

    Bonnard, Charles-Henri; Sirois, Frédéric; Lacroix, Christian; Didier, Gaëtan

    2017-01-01

    In order to plan the integration of superconducting fault current limiters (SFCLs) in power systems, accurate models of SFCLs must be made available in commercial power system transient simulators. In this context, we developed such a model for the EMTP-RV software package, a power system transient simulator widely used by power utilities. The model can be used with any resistive-type SFCL (rSFCL) made of high temperature superconductor (HTS) tapes, which are discretized in ‘electro-thermal elements’. Those elements consist solely of electric circuit components, and are used to represent portions of tape of various sizes and dimensions (a ‘multi-scale’ approach). Both the electrical and thermal behaviors of the tape are modeled, including interfacial effects, nonlinear properties of materials and heat transfer to the surrounding environment. Such a multi-scale model can simulate accurately both the local quench dynamics of HTS tapes (microscopic scale) and the global impact of the rSFCL on the power system (macroscopic/system scale). In this paper, the model is used to compute phenomena such as propagation velocity of a hot spot and heat diffusion through the thickness of the tape. Results were verified by comparing EMTP-RV results with finite element simulations. In addition to the development of the multi-scale model itself, which is the major contribution of this paper, the use of the model allowed us to determine the conditions of validity of the commonly used ‘homogenization’ of the thermal properties across the tape thickness. Indeed, when the current flowing into the rSFCL is slightly above its critical current I c (and up to 2{I}{{c}}), very important errors in the power waveforms arise, leading to potentially wrong decisions of protection systems. Homogenized thermal models should thus be used with great care in practice.

  18. A new method of reconstructing current paths in HTS tapes with defects

    NASA Astrophysics Data System (ADS)

    Podlivaev, Alexey; Rudnev, Igor

    2017-03-01

    We propose a new method for calculating current paths in high-temperature superconductive (HTS) tapes with various defects including cracks, non-superconducting inclusions, and superconducting inclusions with lower local critical current density. The calculation method is based on a model of critical state which takes into account the dependence of the critical current on the magnetic field. The method allows us to calculate the spatial distribution of currents flowing through the defective HTS tape for both currents induced by the external magnetic field and transport currents from an external source. For both cases, we performed simulations of the current distributions in these tapes with different types of defects and have shown that the combination of the action of the magnetic field and transport current leads to a more detailed identification of the boundaries and shape of the defects. The proposed method is adapted for calculating modern superconductors in real superconducting devices and may be more useful as compared to the conventional magnetometric diagnostic studies, when the tape is affected by the magnetic field only.

  19. Analysis of transient state in HTS tapes under ripple DC load current

    NASA Astrophysics Data System (ADS)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  20. An introduction to the design and fabrication progress of a megawatt class 2G HTS motor for the ship propulsion application

    NASA Astrophysics Data System (ADS)

    Moon, Heejong; Kim, Yeong-Chun; Park, Heui-Joo; Yu, In-Keun; Park, Minwon

    2016-03-01

    This paper introduces the design and fabrication progress of a megawatt class 2G high temperature superconductor (HTS) motor for the ship propulsion application at Doosan Heavy Industries and Construction. The purpose of this 2G HTS propulsion motor is to launch the business area for marine applications such as surface ship, submarine, merchant ship etc. The principles and interpretation of the magnetic field for 2G HTS motor and permanent magnet type motors are similar on the basis of 3D design and production. The most important component of an HTS motor is the rotor, which is composed of HTS coil, non-ferrous metal, torque disk, damper, and hollow shaft. A HTS rotor using hastelloy-based 2G HTS coils was designed and built. Open-circuit and short-circuit characteristics of the superconducting motor were investigated and compared with the analysis results at reduced excitation to verify the design. Preliminary testing of a 2G HTS motor has been conducted at a few hundred kilowatts as per the design. Through these results, we anticipate that most of the design criteria can be satisfied. However, we have faced several issues during the testing of the motor and these issues need to be resolved in order to take the design further.

  1. Recent developments in processing HTS silver-clad Bi-2223 tapes, coils and test magnets

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.; Balachandran, U.; Iwasa, Y.; Yunus, M.

    1993-10-01

    Considerable progress has been made in fabricating Bi-2223 high temperature superconductor (HTS) wires and tapes with high critical current densities that are attractive for electric power and high-field magnet applications. Powder-in-tube processed silver-clad Bi-2223 short tape samples, small coils and test magnets have been fabricated and measured at liquid nitrogen (77K), pumped liquid nitrogen (64 K), liquid neon (27K) and liquid helium (4.2K) temperatures. Optimization of thermo-mechanical process parameters have yielded J{sub c}`s in the superconducting core > 4.0 {times} 10{sup 4} A/cm{sup 2} at 77K zero field and > 2.0 {times} 10{sup 5} A/cm{sup 2} at 4.2K, zero field. Long lengths (up to 70 m) of mono-core conductors were fabricated and tested to carry significant amounts of current (23 A, {approximately}15,000 A/cm{sup 2}) at liquid nitrogen temperature. Recent test magnets assembled from pancake wound coils were measured to generate magnetic fields as high as 2.6, 1.8 and 0.36 Tesla at 4.2K, 27K and 77K respectively. These results show promise towards practical utilization of HTS materials.

  2. H-formulation for simulating levitation forces acting on HTS bulks and stacks of 2G coated conductors

    NASA Astrophysics Data System (ADS)

    Sass, F.; Sotelo, G. G.; Junior, R. de Andrade; Sirois, Frédéric

    2015-12-01

    Several techniques to model high temperature superconductors (HTSs) are used throughout the world. At the same time, the use of superconductors in transportation and magnetic bearings promises an increase in energy efficiency. However, the most widespread simulation technique in the literature, the H-formulation, has not yet been used to simulate superconducting levitation. The goal of this work is to present solutions for the challenges concerning the use of the H-formulation to predict the behavior of superconducting levitators built either with YBCO bulks or stacks of 2G wires. It is worth mentioning the originality of replacing bulks with HTS stacks in this application. In our simulation methodology, the movement between the HTS and the permanent magnet was avoided by restricting the simulation domain to the HTS itself, which can be done by applying appropriate boundary conditions and analytical expressions for the source field. Commercial finite element software was used for the sake of ease of implementation. Simulation results were compared with experimental data, showing good agreement. We conclude that the H-formulation is suitable for problems involving moving objects and is a good alternative to other approaches for simulating superconducting magnetic bearings.

  3. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    NASA Astrophysics Data System (ADS)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  4. Measurements of AC Loss In Second-Generation HTS Tapes in a DC Magnetic Field

    NASA Astrophysics Data System (ADS)

    Osofsky, M. S.; Soulen, R. J.; Gubser, D. U.; Datta, T.

    2008-03-01

    The successful application of superconductivity to motors and other power system components depends on the characterization and subsequent minimization of the ac loss in the superconductor used for fabrication of the component. The superconductive component, excited by an ac power source, may be exposed to large dc magnetic fields and/or ac fields. To further complicate the situation, the transport properties of the tapes are strongly dependent on the angle between the applied field and the YBCO c-axis (normal to the tape surface). We report on measurements of the transport ac loss of a YBaCuO tape at 65 K, at several frequencies, in applied dc fields of 1-3 T with the field parallel and perpendicular to the tape normal.

  5. Theoretical estimation of quench occurrence and propagation based on generalized thermoelasticity for LTS/HTS tapes triggered by a spot heater

    NASA Astrophysics Data System (ADS)

    Tong, Yujin; Guan, Mingzhi; Wang, Xingzhe

    2017-04-01

    The present study deals with the thermal characteristics and mechanical behaviors of low/high temperature superconducting (LTS/HTS) composite tapes during quench processes triggered by a spot heater. Based on the generalized thermoelastic theory, a dynamic thermoelastic model with a relaxation time is developed which takes into account the temperature dependence and finite speed of heat propagation for the superconducting tapes under cryogenic condition. The analyses were performed using the finite element method to solve the coupled differential equations of dynamic heat conduction and elastic equilibrium. The results show that the thermoelastic behaviors exhibit a strong relevance to quench characteristics of the superconductors. As a quench occurs, the thermoelastic strain-rate has an obvious jumping variation with the instant of time of its peak being fortunately coincident with the time at which the critical temperature is reached. Such a jumping change of strain-rate could be a way of estimation and detection of quench occurrence, and the theoretical predictions coincide with the existing experimental observations on thermoelastic strain-rate in LTS magnets. For a HTS tape, the thermoelastic strain-rate or temperature-rate variation and a small jump also are illustrated as the quench occurrence is determined. Additionally, the normal zone propagation velocities for the LTS/HTS tapes are predicted by the critical temperature and thermoelastic strain-rate to show quite good agreements with the results evaluated by Wilson’s formula for a LTS tape or the experimental measurements for a HTS tape. The influences of the relaxation time of heat conduction and thermoelastic coupling on the thermal distribution and strain profile are also discussed in details.

  6. Fabrication and characteristics of a test magnet from HTS Bi-2223 silver-clad tapes

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.; Iwasa, Y.

    1993-07-01

    Critical currents of powder-in-tube processed silver-clad Bi-2223 short tape samples and coils have been measured at liquid nitrogen (77 K), liquid neon (27 K) and liquid helium (4.2 K) temperatures. The short samples have been characterized in fields up to 20 T and indicate a large anisotropy at 27 K with resistive behavior above 15 T in the worst field direction. A test magnet consisting of pancake coils generated magnetic fields greater than 1.0, 0.7 and 0.11 T at 4.2 K, 27 K and 77 K respectively. The ctest magnet generates significant self-fields in background fields up to 14.5 T at 4.2 K and 27 K. Optimization of thermo-mechanical process parameters have yielded J{sub c}`s in the superconducting core > 4.0 {times} 10{sup 4} A/cm{sup 2} at 77 K, zero field and > 2.0 {times} 10{sup 5} A/cm{sup 2} at 4.2 K, zero field for short tape samples. Long lengths (>30 m) of silver-clad tape superconductors have also been fabricated and tested to carry significant amounts of current (J{sub c} core > 10,000 A/cm{sup 2}) at 77 K. Overall J{sub c} of short and long samples and characteristics of the test magnet are reported.

  7. The effect of temperature on pinning mechanisms in HTS composites

    NASA Astrophysics Data System (ADS)

    Sotnikova, A. P.; Rudnev, I. A.

    2016-09-01

    Pinning mechanism in samples of second generation tapes (2G) of high-temperature superconductors (HTS) was studied The critical current and the pinning force were calculated from the magnetization curves measured in the temperature range of 4.2 - 77 K in magnetic fields up to 14 Tesla using vibration sample magnetometer. To determine the pinning mechanism the dependences of pinning force on magnetic field were constructed according to the Dew-Hughes model and Kramer's rule. The obtained dependences revealed a significant influence of the temperature on effectiveness of different types of pinning. At low temperatures the 2G HTS tapes of different manufacturers demonstrated an equal efficiency of the pinning centers but with temperature increase the differences in pinning mechanisms as well as in properties and effectiveness of the pinning centers become obvious. The influence of the pinning mechanism on the energy losses in HTS tapes was shown.

  8. A new numerical approach to find current distribution and AC losses in coaxial assembly of twisted HTS tapes in single layer arrangement

    NASA Astrophysics Data System (ADS)

    Siahrang, Majid; Sirois, Frédéric; Grilli, Francesco; Babic, Slobodan; Brault, Simon

    2010-06-01

    This paper presents a novel technique for evaluating AC losses and current distribution in single layer assemblies of coaxially wound thin conductors, such as YBCO coated conductors. The proposed approach takes into account the twisted geometry of the individual superconducting tapes by considering the integral relation between the magnetic vector potential and the current density in the tapes (Biot-Savart formula). The integrals are solved numerically and semi-analytically, and the results are used to generate a discretized system of equations based on the magnetic flux diffusion equation (eddy current problem). The latter is solved using an efficient time transient solver (DASPK). It is assumed that, due to the helical symmetry of the problem, it is sufficient to solve for the current distribution in half of a single tape cross-section, even if many tapes are present, which allows a drastic reduction of the 3-D problem to a simple 1-D domain. The method was used to evaluate the AC losses of a HTS cable made of coated conductors, and it was observed that for a given radius of the former and number of tapes, twisted tapes with smaller pitch have lower AC losses.

  9. Development of HTS power cable using YBCO coated conductor

    NASA Astrophysics Data System (ADS)

    Mukoyama, Shinichi; Yagi, Masashi; Hirano, Hironobu; Yamada, Yutaka; Izumi, Teruo; Shiohara, Yuh

    2006-10-01

    Reductions of AC losses and of cost of HTS power cables are important to put it into practical power networks. Since an YBCO-coated-conductor (YBCO tape) has higher Jc and better magnetic property than a Bi2223-Ag-sheathed-tape, an AC power cable using YBCO tapes will obtain higher performance than XLPE-cables and HTS cables using BSCCO tapes in future. Especially, an YBCO HTS cable will be expected to become a higher economical cable than a Bi cable because an YBCO tape reduced its AC losses and its wire cost. We have started developing HTS power cables using YBCO tapes. Mechanical properties, superconducting properties and other electro magnetic properties of YBCO tapes have been measured to estimate the applicability to the HTS cable. Moreover, we have developed some technologies to bring out latent potentials of YBCO tapes.

  10. Development of synchronous machines with HTS rotor

    NASA Astrophysics Data System (ADS)

    Kummeth, P.; Frank, M.; Nick, W.; Nerowski, G.; Neumueller, H.-W.

    2005-10-01

    Optimized design of synchronous machines can be achieved by use of HTS tape conductors. The introduction of an iron-free air-core stator winding and replacement of the rotor's copper windings by Bi-2223 tapes allows to develop very compact HTS machines with less than half the weight and volume, higher efficiency and excellent operational behavior compared to conventional devices. In consequence these rotating machines with HTS rotors become very attractive for ship drives, power generation and industrial applications. A 400 kW synchronous HTS machine was designed, manufactured and tested at Siemens. Main goal was to demonstrate the feasibility of basic concepts. Development of a 4 MVA synchronous HTS generator is currently under way.

  11. Correlation of local structure peculiarities and critical current density of 2G MOCVD YBCO tapes with BaZrO3 nanoinclusions

    NASA Astrophysics Data System (ADS)

    Menushenkov, A. P.; Ivanov, V. G.; Chepikov, V. N.; Nygaard, R. R.; Soldatenko, A. V.; Rudnev, I. A.; Osipov, M. A.; Mineev, N. A.; Kaul, A. R.; Mathon, O.; Monteseguro, V.

    2017-04-01

    We have studied the influence of BaZrO3 nanoinclusions on the local structure and critical current density of second-generation high temperature superconducting tapes based on YBa2Cu3O7‑δ (YBCO) films. The films were made by metal–organic chemical vapor deposition (MOCVD). The crystal and local structure of the materials under study were analysed by x-ray diffraction and x-ray absorption spectroscopy (EXAFS + XANES). We have found that, being added at MOCVD process, Zr forms BaZrO3 nanoinclusions in YBCO matrix. The distance between Zr and the neighboring atoms is shorter than that one in a bulk crystalline BaZrO3, so we conclude that the nanoinclusions are in compressed state. The incorporation of 5 mol% BaZrO3 minimizes the static disorder of Cu–O bonds and maximizes their stiffness in YBCO. We show that the local structure peculiarities correlate well with the observed critical current behavior and consider this to be additional evidence in favor of small amounts of BaZrO3 nanoinclusions as efficient pinning centers.

  12. Design and manufacture of a D-shape coil-based toroid-type HTS DC reactor using 2nd generation HTS wire

    NASA Astrophysics Data System (ADS)

    Kim, Kwangmin; Go, Byeong-Soo; Sung, Hae-Jin; Park, Hea-chul; Kim, Seokho; Lee, Sangjin; Jin, Yoon-Su; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2014-09-01

    This paper describes the design specifications and performance of a real toroid-type high temperature superconducting (HTS) DC reactor. The HTS DC reactor was designed using 2G HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The target inductance of the HTS DC reactor was 400 mH. The expected operating temperature was under 20 K. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. Performances of the toroid-type HTS DC reactor were analyzed through experiments conducted under the steady-state and charge conditions. The fundamental design specifications and the data obtained from this research will be applied to the design of a commercial-type HTS DC reactor.

  13. Development of (RE)BCO cables for HTS power transmission lines

    NASA Astrophysics Data System (ADS)

    Mukoyama, S.; Yagi, M.; Masuda, T.; Amemiya, N.; Ishiyama, A.; Kashima, N.; Nagaya, S.; Aoki, Y.; Yoshizumi, M.; Yamada, Y.; Izumi, T.; Shiohara, Y.

    2009-10-01

    High-temperature superconducting (HTS) power cables transmit bulk power with lower loss than conventional cables. Moreover, HTS cables are expected to be constructed as a new underground cable in urban areas at lower cost compared to a high voltage XLPE cable. To put promising HTS cables to practical use, we need (RE)BCO tapes with long length, high critical current, and low cost. Recently many organizations have improved the performance of the (RE)BCO tapes, such as YBCO tapes, or other coated conductor tapes that are made with a variety of different processes. We have fabricated the conductors for the HTS power cable that was constructed of different kinds of (RE)BCO tapes and measured the I c and AC losses. We achieved significantly low AC loss of 0.1 W/m at 1 kA in the HTS conductor using narrow slit tapes that were cut by laser. Moreover, a 20 m long HTS power cable model and a cable intermediate joint were developed. Short circuit current tests were conducted on the cable system that consisted of two 10 m cables, a cable joint, and two terminations. The cables and the joint withstood the short circuit current of 31.5 kA for 2 s without damage.

  14. Reflective HTS switch

    DOEpatents

    Martens, J.S.; Hietala, V.M.; Hohenwarter, G.K.G.

    1994-09-27

    A HTS (High Temperature Superconductor) switch includes a HTS conductor for providing a superconducting path for an electrical signal and an serpentine wire actuator for controllably heating a portion of the conductor sufficiently to cause that portion to have normal, and not superconducting, resistivity. Mass of the portion is reduced to decrease switching time. 6 figs.

  15. Reflective HTS switch

    SciTech Connect

    Martens, Jon S.; Hietala, Vincent M.; Hohenwarter, Gert K. G.

    1994-01-01

    A HTS switch includes a HTS conductor for providing a superconducting path for an electrical signal and an serpentine wire actuator for controllably heating a portion of the conductor sufficiently to cause that portion to have normal, and not superconducting, resistivity. Mass of the portion is reduced to decrease switching time.

  16. AC Losses of Prototype HTS Transmission Cables

    SciTech Connect

    Demko, J.A.; Dresner, L.; Hughey, R.L.; Lue, J.W.; Olsen, S.K.; Sinha, U.; Tolbert, J.C.

    1998-09-13

    Since 1995 Southwire Company and Oak Ridge National Laboratory (ORNL) have jointly designed, built, and tested nine, l-m long, high temperature superconducting (HTS) transmission cable prototypes. This paper summarizes the AC loss measurements of five of the cables not reported elsewhere, and compares the losses with each other and with theory developed by Dresner. Losses were measured with both a calorimetric and an electrical technique. Because of the broad resistive transition of the HTS tapes, the cables can be operated stably beyond their critical currents. The AC losses were measured in this region as well as below critical currents. Dresner's theory takes into account the broad resistive transition of the HTS tapes and calculates the AC losses both below and above the critical current. The two sets of AC 10SS data agree with each other and with the theory quite welL In particular, at low currents of incomplete penetration, the loss data agree with the theoretical prediction of hysteresis loss based on only the outer two Iayers carrying the total current.

  17. Continuous critical current measurement of high-temperature superconductor tapes with magnetic substrates using magnetic-circuit method.

    PubMed

    Zou, S N; Gu, C; Qu, T M; Han, Z

    2013-10-01

    The critical current (I(c)) of high-temperature superconductor (HTS) tapes has to be examined not only for short samples, but also for the entire tape, because local weak points can possibly lead to the quenching of the whole HTS device. Some methods were reported for continuous I(c) measurement along the length of a HTS tape, but few of them were applicable to tapes with magnetic substrates represented by YBa2Cu3O(7-δ)(YBCO)-coated conductors based on Ni5W alloy substrate by rolling assisted bi-axially textured substrate process. We previously presented a contact-free method using magnetic circuits to measure I(c) continuously of long HTS tapes, namely the magnetic-circuit (MC) method. This method has been previously applied with high speed and resolution to measure I(c) of HTS tapes with non-magnetic substrates, due to its resistance to noise aroused by mechanical vibration. In this work, its ability to measure HTS tapes with magnetic substrates is demonstrated both theoretically and experimentally. A 100 m long commercial YBCO tape based on Ni5W alloy substrate was measured and regular I(c) fluctuations were discovered. The MC method can be a powerful tool for quality control of HTS tapes, especially for tapes with magnetic substrates.

  18. TEST RESULTS OF HTS COILS AND AN R AND D MAGNET FOR RIA.

    SciTech Connect

    GUPTA, R.; ANERELLA, M.; HARRISON, M.; SCHMALZLE, J.; SAMPSON, W.; ZELLER, A.

    2005-05-16

    This paper presents the successful construction and test results of a magnetic mirror model for the Rare Isotope Accelerator (RIA) that is based on High Temperature Superconductors (HTS). In addition, the performance of thirteen coils (each made with {approx}220 meters of commercially available HTS tape) is also presented. The proposed HTS magnet is a crucial part of the R&D for the Fragment Separator region where the magnets are subjected to several orders of magnitude more radiation and energy deposition than typical beam line and accelerator magnets receive during their entire lifetime. A preliminary design of an HTS dipole magnet for the Fragment Separator region is also presented.

  19. RADIATION RESISTANT HTS QUADRUPOLES FOR RIA.

    SciTech Connect

    GUPTA,R.; ANERELLA,M.; HARRISON,M.; ET AL.

    2004-10-03

    Extremely high radiation, levels with accumulated doses comparable to those in nuclear reactors than in accelerators, and very high heat loads ({approx}15 kw) make the quadrupole magnets in the fragment separator one of the most challenging elements of the proposed Rare Isotope Accelerator (RIA). Removing large heat loads, protecting the superconducting coils against quenching, the long term survivability of magnet components, and in particular, insulation that can retain its functionality in such a harsh environment, are the major challenges associated with such magnets. A magnet design based on commercially available high temperature superconductor (HTS) and stainless steel tape insulation has been developed. HTS will efficiently remove these large heat loads and stainless steel can tolerate these large radiation doses. Construction of a model magnet has been started with several coils already built and tested. This paper presents the basic magnet design, results of the coil tests, the status and the future plans. In addition, preliminary results of radiation calculations are also presented.

  20. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    NASA Astrophysics Data System (ADS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-12-01

    HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate.

  1. The method of measuring the temperature dependence of the critical current of the HTS-2

    NASA Astrophysics Data System (ADS)

    Yashkin, D. S.; Krasnoperov, E. P.; Brazhnik, P. A.; Kruglov, V. S.

    2016-09-01

    A new method of measurement of Ic(T) dependence for the HTS-2 tape is realized. In this method, the metal substrate of the tape is used as both a heater and a thermometer. Index n(T) was calculated from the measured current-voltage characteristics (CVC). For the tape manufactured by SuperPower Inc. the data of n-index temperature dependence in the range from 77 K up to 90 K are presented.

  2. Review of activities in USA on HTS materials

    SciTech Connect

    Peterson, D.E.

    1995-02-01

    Rapid progress in attaining practical applications of High Temperature Superconductors (HTS) has been made since the discovery of these new materials. Many critical parameters influencing HTS powder synthesis and wire processing have been identified through a combination of fundamental exploration and applied research. The complexity of these novel materials with regard to phase behavior and physical properties has become evident as a result of these careful studies. Achieving optimal mechanical and superconducting properties in wires and tapes will require further understanding and synergy among several different technical disciplines. Highlights of efforts towards producing practical superconductors for electric power applications based on rare earth-, bismuth-, and thallium-based systems are reviewed.

  3. Reduction of Thermal Loss in HTS Windings by Using Magnetic Flux Deflection

    NASA Astrophysics Data System (ADS)

    Tsuzuki, K.; Miki, M.; Felder, B.; Koshiba, Y.; Izumi, M.; Umemoto, K.; Aizawa, K.; Yanamoto, T.

    Efforts on the generation of intensified magnetic flux have been made for the optimized shape of HTS winding applications. This contributes to the high efficiency of the rotating machines using HTS windings. Heat generation from the HTS windings requires to be suppressed as much as possible, when those coils are under operation with either direct or alternative currents. Presently, the reduction of such thermal loss generated by the applied currents on the HTS coils is reported with a magnetic flux deflection system. The HTS coils are fixed together with flattened magnetic materials to realize a kind of redirection of the flux pathway. Eventually, the magnetic flux density perpendicular to the tape surface (equivalent to the a-b plane) of the HTS tape materials is reduced to the proximity of the HTS coil. To verify the new geometry of the surroundings of the HTS coils with magnetic materials, a comparative study of the DC coil voltage was done for different applied currents in prototype field-pole coils of a ship propulsion motor.

  4. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Thomas, R. D. (Inventor)

    1973-01-01

    A thermocouple which may be rolled as a tape until needed and a method of making it are described. Thermoelectrically different metals are applied to a strip of electrically nonconductive material in longitudinally overlapping relationship. Apertures may be provided along the tape in overlapping region at predetermined intervals. An adhesive material is applied to the side of the tape opposite the thermoelectric metals either before or after the thermoelectric metals are deposited. The tape may be cut or torn to form a thermocouple device which is ready for application to a body whose temperature is to be monitored or measured.

  5. Development of toroid-type HTS DC reactor series for HVDC system

    NASA Astrophysics Data System (ADS)

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-11-01

    This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  6. Thermal analysis of HTS air-core transformer used in voltage compensation type active SFCL

    NASA Astrophysics Data System (ADS)

    Song, M.; Tang, Y.; Li, J.; Zhou, Y.; Chen, L.; Ren, L.

    2010-11-01

    The three-phase voltage compensation type active superconducting fault current limiter (SFCL) is composed of three HTS air-core transformers and a three-phase four-wire Pulse Width Modulation (PWM) converter. The primary winding of the each phase HTS air-core transformer is in series with the main system, and the second winding is connected with the PWM converter. The single-phase conduction-cooled HTS air-core transformer is consisting of four double-pancakes wound by the Bi2223/Ag tape. In this paper, according to the electromagnetic analysis on the single-phase HTS air-core transformer, its AC loss corresponding to different operation modes is calculated. Furthermore, the thermal behaviors are studied by the time-stepping numerical simulations. On the basis of the simulation results, the related problems with the HTS air-core transformer's thermal stability are discussed.

  7. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  8. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  9. HTS magnetic bearings

    NASA Astrophysics Data System (ADS)

    Werfel, Frank N.; Flögel-Delor, Uta; Rothfeld, Rolf; Wippich, Dieter; Riedel, Thomas

    2002-08-01

    Radial HTS magnetic bearings (SMB) up to 200 mm size are developed and tested in prototype fast rotating machines to demonstrate the potential to replace conventional bearings. The individual rotational bearing components HTS and PM, their physical interaction and technology is reviewed. Characterisation experiments are conducted to understand the rotor dynamic behaviour. In terms of unbalance and critical speeds the suspended wheels and rotors compare favourably with conventional bearing devices. The rationale of our present bearing technology lies in the assembling of both low-speed magnetic bearings for centrifugal and wafer processing units up to 20,000 rpm as well as a high-speed optical mirror accelerated to rim speed of more than 500 m/s (174,000 rpm) confirming stable low-drag and low energy operation. Two new-type U shaped semicircle HTS bearings coupled each with a 6 W/80 K cryocooler of the Stirling type allow the contact-free operation of a Si wafer carrier in semiconductor wet processes.

  10. Interfacial bonding enhancement of reel-to-reel selective electrodeposition of copper stabilizer on a multifilamentary second-generation high-temperature superconductor tape

    NASA Astrophysics Data System (ADS)

    Cai, Xinwei; Li, Wei; Bose, Anima; Selvamanickam, Venkat

    2016-10-01

    A reel-to-reel copper selective electrodeposition process over a multifilamentary second-generation high-temperature superconductor (2G-HTS) has been demonstrated in our previous work. If the interfacial bonding between the deposited copper layer and the underlying silver overlayer is weak, it might lead to delamination in applications including magnets, motors and generators. In this study, two approaches have been used to improve the copper-silver bonding without the degradation of superconductor performance. The first approach is acidifying the electrolyte by adding sulfuric acid, by which the kinetics of copper electrodeposition is enhanced, resulting in finer microstructure at the copper-silver interface and thus, improved interfacial bonding strength. The second approach consists of blocking the electrolyte outflow at the entrance of the reel-to-reel electroplating cell, by which the occurrence of large copper seeds on the tape caused by the heavy turbulence flow is effectively prevented. With these two improvements together deployed in the process, the peeling strength between the copper and silver layers of the 2G-HTS tape has been improved from <0.3 N to >2 N in 90° peeling and from <0.5 N to >3.0 N in 180° peeling, without any degradation on the superconducting performance.

  11. Magnetization loss for stacks of ReBCO tapes

    NASA Astrophysics Data System (ADS)

    Bykovsky, N.; De Marzi, G.; Uglietti, D.; Bruzzone, P.; Muzzi, L.

    2017-02-01

    The AC loss measurements of the high temperature superconductor (HTS) cable prototype in the EDIPO test facility motivated detailed investigations of the loss contributions from the tape, strand and cable stages of the HTS fusion conductor design proposed at the Swiss Plasma Center. As an initial step of the task, magnetization tests of soldered stacks of HTS tapes were carried out at temperatures of 5 and 77 {{K}} and magnetic fields up to 12 {{T}} using the vibrating sample magnetometer technique. The influence on the magnetization loss of the number of tapes, width of the tape, field’s orientation and tape’s manufacturer is studied experimentally performing both the major and minor magnetization loops with different ramp rates of the applied magnetic field. In order to validate the test results, a numerical model is developed and presented in this work. From the numerical model we also deduced an analytical approach for the magnetization loss in the stacks of tapes with arbitrary number of tapes in the critical state model. Comparison between the measured and estimated magnetization loss of the cable prototypes is reported as well.

  12. DEVELOPMENT OF HTS CONDUCTORS FOR ELECTRIC POWER APPLICATIONS

    SciTech Connect

    Goyal, A.; Rupich, M.

    2012-10-23

    Second generation (2G) technologies to fabricate high-performance superconducting wires developed at the Oak Ridge National Laboratory (ORNL) were transferred to American Superconductor via this CRADA. In addition, co-development of technologies for over a decade was done to enable fabrication of commercial high-temperature superconducting (HTS) wires with high performance. The massive success of this CRADA has allowed American Superconductor Corporation (AMSC) to become a global leader in the fabrication of HTS wire and the technology is fully based on the Rolling Assisted Biaxially Textured Substrates (RABiTS) technology invented and developed at ORNL.

  13. Thermocouple tape

    NASA Technical Reports Server (NTRS)

    Mazaris, G. A., Jr.; Thomas, R. D.

    1972-01-01

    Preformed, low cost, thin film thermocouples on adhesive tapes were fabricated. Metal strips of two dissimilar metals were laid on opposite edges of plastic substrate so that they overlap in center portion, forming thermocouple junction. Useful temperature range for polyimide films was 4 to 673 K.

  14. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  15. Investigation on quench initiation and propagation characteristics of GdBCO coil co-wound with a stainless steel tape as turn-to-turn metallic insulation

    NASA Astrophysics Data System (ADS)

    Kim, Y. G.; Song, J. B.; Choi, Y. H.; Yang, D. G.; Kim, S. G.; Lee, H. G.

    2016-11-01

    This paper investigates the quench initiation and propagation characteristics of a metallic insulation (MI) coil by conducting thermal quench tests for a GdBCO single-pancake coil co-wound with a stainless steel tape as the turn-to-turn MI. The test results confirmed that the MI coil exhibited superior thermal and electrical stabilities compared to the conventional coils co-wound with organic insulation material because the operating current could flow along the radial direction due to the existence of a turn-to-turn contact when a local hot spot was generated. The results of the quench test at a heater current (Ih) of 12, 13, and 14 A indicate that the MI coil possesses a self-protecting characteristic resulting from the "current bypass" through the turn-to-turn contact. However, the test coil was not self-protecting at Ih = 15 A because the Joule heat energy generated by the radial current flow was not completely dissipated due to the characteristic resistance of the metallic insulation tape and the non-superconducting materials, including the substrate, stabilizer, and buffer layers within the high-temperature superconductor (HTS) tape. Even though the MI coil possesses superior thermal and electrical stability relative to those of conventional HTS coils co-wound with an organic material as turn-to-turn insulation, it is essential to consider the critical role of the Joule heat energy resulting from the operating current and stored magnetic energy as well as the characteristic resistances in order to further develop self-protective 2G HTS magnets.

  16. Investigation on quench initiation and propagation characteristics of GdBCO coil co-wound with a stainless steel tape as turn-to-turn metallic insulation.

    PubMed

    Kim, Y G; Song, J B; Choi, Y H; Yang, D G; Kim, S G; Lee, H G

    2016-11-01

    This paper investigates the quench initiation and propagation characteristics of a metallic insulation (MI) coil by conducting thermal quench tests for a GdBCO single-pancake coil co-wound with a stainless steel tape as the turn-to-turn MI. The test results confirmed that the MI coil exhibited superior thermal and electrical stabilities compared to the conventional coils co-wound with organic insulation material because the operating current could flow along the radial direction due to the existence of a turn-to-turn contact when a local hot spot was generated. The results of the quench test at a heater current (Ih) of 12, 13, and 14 A indicate that the MI coil possesses a self-protecting characteristic resulting from the "current bypass" through the turn-to-turn contact. However, the test coil was not self-protecting at Ih = 15 A because the Joule heat energy generated by the radial current flow was not completely dissipated due to the characteristic resistance of the metallic insulation tape and the non-superconducting materials, including the substrate, stabilizer, and buffer layers within the high-temperature superconductor (HTS) tape. Even though the MI coil possesses superior thermal and electrical stability relative to those of conventional HTS coils co-wound with an organic material as turn-to-turn insulation, it is essential to consider the critical role of the Joule heat energy resulting from the operating current and stored magnetic energy as well as the characteristic resistances in order to further develop self-protective 2G HTS magnets.

  17. Multi-channel Data Acquisition System for a 500 m DC HTS Power Cable in Ishikari

    NASA Astrophysics Data System (ADS)

    Ivanov, Yury V.; Chikumoto, Noriko; Watanabe, Hirofumi; Takano, Hirohisa; Inoue, Noriyuki; Yamaguchi, Satarou

    Reduction of heat penetrating into the cryogenic region is the important method of optimization of superconducting devices. In the cases of short-range power transmission lines and compact HTS devices like magnets, the heat leakage through current leads is relatively large. In order to decrease this contribution, current leads equipped with Peltier elements can be used. The mentioned technology is being actively developed in the Chubu University. Commercial samples of Peltier current leads are installed at the terminals of 500-meter DC HTS cable in Ishikari (Hokkaido). This cable is designed for 5 kA. The inner conducting layer consists of 37 DI-BSCCO HTS tapes from Sumitomo Electric Industries, Ltd. with a critical current of 180 A; and the outer one consists of 35 tapes of the same type. Each end of the cable's tape is connected to the individual Peltier current lead. Accordingly, each of the two terminals is equipped with 72 Peltier current leads, 144 pieces in total. In order to examine behavior of the current leads in detail, each piece is supplied with two thermocouples; there are also voltage taps on feedthrough and on HTS tape end. In addition, current through Peltier current lead can be measured by means of individual current transformer. The hardware part of the data acquisition system includes four Keithley 3706A multimeters equipped with 60-channel model 3724 FET multiplexer cards. Therefore, 144 data blocks are formed. Furthermore, there are 72 measurements of a voltage drop across HTS tape. Sampling period is set to be 3 s. The program part of the data acquisition system was written using LabVIEW software solution (National Instruments Corp.).

  18. Development of Prototype HTS Components for Magnetic Suspension Applications

    NASA Technical Reports Server (NTRS)

    Haldar, P.; Hoehn, J., Jr.; Selvamanickam, V.; Farrell, R. A.; Balachandran, U.; Iyer, A. N.; Peterson, E.; Salazar, K.

    1996-01-01

    We have concentrated on developing prototype lengths of bismuth and thallium based silver sheathed superconductors by the powder-in-tube approach to fabricate high temperature superconducting (HTS) components for magnetic suspension applications. Long lengths of mono and multi filament tapes are presently being fabricated with critical current densities useful for maglev and many other applications. We have recently demonstrated the prototype manufacture of lengths exceeding 1 km of Bi-2223 multi filament conductor. Long lengths of thallium based multi-filament conductor have also been fabricated with practical levels of critical current density and improved field dependence behavior. Test coils and magnets have been built from these lengths and characterized over a range of temperatures and background fields to determine their performance. Work is in progress to develop, fabricate and test HTS windings that will be suitable for magnetic suspension, levitation and other electric power related applications.

  19. Design and optimization of a HTS insert for solenoid magnets

    NASA Astrophysics Data System (ADS)

    Tomassetti, Giordano; de Marzi, Gianluca; Muzzi, Luigi; Celentano, Giuseppe; della Corte, Antonio

    2016-12-01

    With the availability of High-Temperature Superconducting (HTS) prototype cables, based on high-performance REBCO Coated Conductor (CC) tapes, new designs can now be made for large bore high-field inserts in superconducting solenoids, thus extending the magnet operating point to higher magnetic fields. In this work, as an alternative approach to the standard trial-and-error design process, an optimization procedure for a HTS grading section design is proposed, including parametric electro-magnetic and structural analyses, using the ANSYS software coupled with a numerically-efficient optimization algorithm. This HTS grading section is designed to be inserted into a 12 T large bore Low-Temperature Superconducting (LTS) solenoid (diameter about 1 m) to increase the field up to a maximum value of at least 17 T. The optimization variables taken into consideration are the number of turns and layers and the circle-in-square jacket inner diameter in order to minimize the total needed conductor length to achieve a peak field of at least 17 T, while guaranteeing the structural integrity and manufacturing constraints. By means of the optimization, an optimal 360 m total conductor length was found, achieving 17.2 T with an operating current of 22.4 kA and a coil comprised of 18 × 12 turns, shortened of about 20% with respect to the best initial candidate architectural design. The optimal HTS insert has a bore compatible with manufacturing constraints (inner bore radius larger than 30 cm). A scaled HTS insert for validation purposes, with a reduced conductor length, to be tested in an advanced experimental facility currently under construction, is also mentioned.

  20. Progress in American Superconductor's HTS wire and optimization for fault current limiting systems

    NASA Astrophysics Data System (ADS)

    Malozemoff, Alexis P.

    2016-11-01

    American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25-50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires' critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and decreasing its critical J. This conflicts with other desirable wire characteristics. Optimization of these conflicting requirements is discussed.

  1. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  2. HTS magnetometers for fetal magnetocardiography.

    PubMed

    Li, Z; Wakai, R T; Paulson, D N; Schwartz, B

    2004-11-30

    High temperature superconducting (HTS) SQUID sensors have adequate magnetic field sensitivity for adult magnetocardiography (MCG) measurements, but it remains to be seen how well they perform for fetal MCG (fMCG), where the heart signals are typically ten times smaller than the adult signals. In this study, we assess the performance of a prototype HTS SQUID system; namely, a three-SQUID gradiometer formed from three vertically-aligned HTS dc-SQUID magnetometers integrated into a fiberglass liquid nitrogen dewar of diameter 12.5 cm and height 30 cm. Axial gradiometers with short or long baseline, as well as a second order gradiometer, can be formed out of these magnetometers via electronic subtraction. The calibrated magnetometer sensitivities at 1 kHz are 109 fT/square root of Hz, 155 fT/square root of Hz and 51 fT/square root of Hz. Direct comparison is made between the HTS SQUID system and a LTS SQUID system by making recordings with both systems during the same session on adult and fetal subjects. Although the fMCG could be resolved with the HTS SQUID system in most near-term subjects, the signal-to-noise ratio was relatively low and the system could not be operated outside of a shielded room.

  3. Performance of HTS SQUID coupled to cooled-Cu/superconductor pickup coil

    NASA Astrophysics Data System (ADS)

    Enpuku, K.; Tsuji, Y.; Hirakawa, S.; Matsuo, M.; Yoshida, T.

    2010-11-01

    We studied the performance of a magnetometer composed of a high Tc SQUID and a large pickup coil. For the pickup coil, we consider the coil made of a cooled Cu wire or an HTS superconductor tape. A magnetometer was designed for geophysical measurement using transient electromagnetic method. The theoretical field noise of the magnetometer was 0.2-1 pT/Hz1/2 at f = 10 Hz, and 55 fT/Hz1/2 for f > 200 Hz when the pickup coil of 100 mm in diameter and of N = 50 turns was used. Preliminary experimental results using the pickup coil made of the HTS Bi-tape reasonably agreed with the theoretical prediction.

  4. Partial Discharge Characteristics in Composite Insulation Systems with PPLP for HTS Cable

    NASA Astrophysics Data System (ADS)

    Kikuchi, Y.; Yamashita, K.; Kumada, A.; Hidaka, K.; Tatamidani, K.; Masuda, T.

    2014-05-01

    The electrical insulation system of high-temperature superconducting (HTS) cable consists of liquid nitrogen (N2(l)) and polypropylene laminated paper (PPLP). Partial discharge (PD) may occur in butt gaps of the insulation layers and its characteristics imply the insulation performance of HTS cables. N2(l) cooling system is installed in the power system and N2(l) will flow through the cables during the system operation. Filling the HTS cable with N2(l) in order to perform pre-shipment inspection is time-consuming and costly for cable manufacturers. Therefore, they are trying to find a cost effective method for pre-shipment inspections. One alternative is to use high pressure gaseous nitrogen (N2(g)) instead of N2(l). This article investigates PD characteristics such as PD inception electric field (PDIE) and PD extinction electric field (PDEE) in butt gaps of HTS cables in 0.1 to 0.3 MPa and 0.1 MPa to 1.0 MPa N2(g) environments. For assessing the surface/volume effects, PD characteristics are measured with changing the size of butt gaps. It turns out that PDIE and PDEE in N2(g) are linearly correlated with those in N2(l) at any gas pressure in our testing, and PDIE in 1.0 MPa N2(g) is almost 30% of that in 0.2 MPa It suggests that PD characteristics in N2(l) can be extrapolated from those in N2(g).

  5. Strengthening future electricity grid of the Netherlands by integration of HTS transmission cables

    NASA Astrophysics Data System (ADS)

    Zuijderduin, Roy; Chevtchenko, Oleg; Smit, Johan; Aanhaanen, Gert; Ross, Rob

    2014-05-01

    The electricity grid of the Netherlands is changing. There is a call of society to use more underground cables, less overhead lines (OHL) and to reduce magnetic emissions. At the same time, parts of the future transmission grid need strengthening depending on the electricity demand in the coming decades [1]. Novel high temperature superconductor (HTS) AC transmission cables can play a role in strengthening the grid. The advantages as compared to alternatives, are: economic, underground, higher power capacity, lower losses, reduced magnetic field emissions in (existing) OHL, compact: less occupation of land and less permits needed, a possibility to keep 380 kV voltage level in the grid for as long as needed. The main obstacles are: the relatively high price of HTS tapes and insufficient maturity of the HTS cable technology. In the paper we focus on a 34 km long connection in the transmission grid (to be strengthened in three of the four of TenneT scenarios [1]), present the network study results, derive the requirements for corresponding HTS transmission cable system and compare HTS system to the alternatives (OHLs and XLPE cables).

  6. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  7. Test results from Siemens low-speed, high-torque HTS machine and description of further steps towards commercialisation of HTS machines

    NASA Astrophysics Data System (ADS)

    Nick, Wolfgang; Grundmann, Joern; Frauenhofer, Joachim

    2012-11-01

    With extensive testing of the 4 MW 120 rpm HTS machine connected to a standard Siemens converter this first development stage for a basically new technology is concluded. The most innovative part of the machine, the HTS excited rotor, outperformed our expectations and demonstrated our capability to design, develop and build successfully such a technically challenging component. This could only be achieved on the base of a thorough understanding of the innovative material and its behaviour including practical handling experience, the ability to simulate 3D electromagnetics including transients, and finally transfer of the scientists' knowledge to a qualified manufacturing process. Equally important are the improved capabilities of critical component suppliers, e.g. for superconducting tapes and compact cryo-refrigerators. However, the transition of a technology into highly reliable industrial products does require more than technical mastering of the machine. Based on outstanding technical test results as presented above, the next step in future can be addressed: product development. Some thoughts will be presented regarding the needs of application fields and market oriented development, as the market is not "waiting for HTS". If HTS technology is seen as one key technology for a sustainable, material saving and energy efficient future, it certainly needs more effort, even at the 100th anniversary of superconductivity.

  8. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  9. Large Scale Applications of HTS in New Zealand

    NASA Astrophysics Data System (ADS)

    Wimbush, Stuart C.

    New Zealand has one of the longest-running and most consistently funded (relative to GDP) programmes in high temperature superconductor (HTS) development and application worldwide. As a consequence, it has a sustained breadth of involvement in HTS technology development stretching from the materials discovery right through to burgeoning commercial exploitation. This review paper outlines the present large scale projects of the research team at the newly-established Robinson Research Institute of Victoria University of Wellington. These include the construction and grid-based testing of a three-phase 1 MVA 2G HTS distribution transformer utilizing Roebel cable for its high-current secondary windings and the development of a cryogen-free conduction-cooled 1.5 T YBCO-based human extremity magnetic resonance imaging system. Ongoing activities supporting applications development such as low-temperature full-current characterization of commercial superconducting wires and the implementation of inductive flux-pump technologies for efficient brushless coil excitation in superconducting magnets and rotating machines are also described.

  10. VLBA: Formatter to Tape

    NASA Astrophysics Data System (ADS)

    Rogers, A. E. E. R.

    Introduction; Why Magnetic Tape?; VLBI Recording Systems; The VLBA Data Format; Longitudinal Format; Transverse Track Format; Data and Non-Data Replacement; Track Width and Track Structure; The VLBA Formatter; Switch Board; Header Control Board; Transport Driver Board; Timing and Control Board; DataBuffer Board; Analysis Board; Magnetic Recording Fundamentals; Recording Losses; Wavelength Response; Head-to-Tape Contact and Tribology; The VLBA Recorder; The Tape Transport; The Headstack; The Headstack Positioner; Control Electronics; Signal Electronics and Eye Pattern; Characteristics and Limitations; Error Rate Versus Bit Density; Tape Thickness Interchange; Head Flying; Overwrite; Tracking Errors; Headlife and Humidity; Thin Tape and Edge Damage by Frictional Heating; Tape Reel and Shipping Canister; Future VLBI Recording Systems; Expansion Paths for the VLBA Formatter; Recorder Improvements; Thinner Tape; Higher Data Rates; Next Generation of Heads; Mark IV; Summary and Conclusions

  11. Feasibility study for reduction of the screening current induced field in a 2G high temperature superconducting coil

    NASA Astrophysics Data System (ADS)

    Hwang, Y. J.; Jang, J. Y.; Ahn, M. C.; Park, Y. G.; Lee, S. G.

    2016-10-01

    This paper reports the effects of thermal energy on reducing the overshoot of the current sweep cycle method to reduce the screening current-induced field (SCF) in a 2G high temperature superconducting (HTS) coil. A disadvantage of the current sweep cycle method is the necessity for large overshoot in the coil current. For a 2G HTS coil, excessive overshooting of the coil current is undesirable (Yanagisawa et al 2012 AIP Conf. Proc. 1434 1373-8). In an effort to circumvent this overshooting problem, the thermal energy effect was investigated in combination with the current sweep cycle method based on experiments in this study. The experimental results show that greater SCF reduction in the HTS coil was obtained upon increasing thermal energy by heater current.

  12. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  13. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  14. Dielectrically Loaded HTS Spiral Antenna

    NASA Astrophysics Data System (ADS)

    Ramasamy, J.; Hanna, D.; Vlasov, Y. A.; Larkins, G. L.; Moeckly, B. H.

    2004-06-01

    The objective of this work is to fabricate, test, and study a dielectrically loaded high temperature superconductor (HTS) spiral antenna that would operate in the frequency band of 10 MHz to 200 MHz. The antenna is formed by depositing and patterning a YBa2Cu3O7 (YBCO) thin film on top of 4-inch-diameter sapphire and Yittria Stabilized ZrO2 substrates. The presence of the HTS material guarantees low conductor loss in the antenna. A thick epitaxial layer of strontium titanate (STO) is then deposited on top of the YBCO for high dielectric constant loading. This set-up can be simulated using the Fidelity software routine, a Finite Difference Time Domain based program from Zeland, Inc. We have simulated the performance of this antenna structure, first in free space and then after loading with the dielectric slabs. Important parameters such as feed point impedance and antenna gain are studied for different simulation conditions. The dielectric ensures reduced feed point impedance as well as improvement of the low frequency response of the antenna.

  15. Experimental Study of Local Micro-forming for Bi-HTS

    SciTech Connect

    Zeng Pan; Lu Yongjin; Lei Liping; Qu Timing; Fang Gang

    2010-06-15

    The Bi-HTS (BSCCO high temperature superconductor) tape now has become the product in an industrial way, which has been available to apply in electric and electron fields. The main way to manufacture Bi-HTS tape is to use the technique of oxide powder in silver tube (OPIT), which involves the multi-step drawing and rolling with plastic deformation, which obviously belongs to a type of the micro-forming in macro-scale processing. There are two main characteristics founded: (a) contact and friction between silver and BSCCO surfaces, (b) interface between two materials. A series of micro-tensile experiments of silver foil with thicknesses of 0.03, 0.06 and 0.1 mm are designed to investigate the behaviors of silver with various scale of sizes. And the surface topography measurements have been carried out to analyze the changes in surface topography. Based upon experiments, some topics are researched which are referred to inhomogeneous, local effect, size effect, grain and micro-structure affecting, surface roughness, long-distance sausage phenomenon. Further the local breakdown of silver by Bi-HTS powder during process is analyzed through failure criterion. The results of this work will bring out an important exploration value to the theory and computation of micro-forming.

  16. Basic concepts, status, opportunities, and challenges of electrical machines utilizing high-temperature superconducting (HTS) windings

    NASA Astrophysics Data System (ADS)

    Frauenhofer, J.; Grundmann, J.; Klaus, G.; Nick, W.

    2008-02-01

    An overview of the different approaches towards achieving a marketable application of a superconducting electrical machine, either as synchronous motor or generator, will be given. This field ranges from relatively small industrial drives to utility generators with large power ratings, from the low speed and high torque of wind power generators and ship propulsion motors, to high speed generators attached to turbines. Essentially HTS machine technology offers several advantages such as compactness (weight and volume reduction), increased efficiency, and other operational benefits. The machine features have to be optimized with regard to the specific application, and different concepts were developed by internationally competing teams, with Siemens being one of them. The achieved status in these fields will be summarized, pointing to the specific technical challenges to overcome. For this purpose we have not only to consider the technology of manufacturing the HTS rotor winding itself, but also to check requirements and availability of supporting technologies. This ranges from new challenges posed to the non-superconducting ("conventional") components of such innovative HTS machines, manufacturing superconducting material in the coming transition from 1st to 2nd generation HTS tape, cryogenic technology including material behavior, to new and challenging tasks in simulating and predicting the performance of such machines by computational tools. The question of market opportunities for this technology obviously is a function of all these aspects; however, a strong tendency for the near future is seen in the area of high-torque ship propulsion.

  17. ERTS wideband tape recorder

    NASA Technical Reports Server (NTRS)

    Hayes, J. M.

    1973-01-01

    The ERTS video bandwith tape recorder uses a rotary head to run the tape in transverse mode; the head wheel gives a head-to-tape surface speed of nearly 5080 centimeter per second. The electronics unit handles 15 megabit per second rate with a bit-error rate of 0.00001. An operational unit onboard ERTS A returned images from the 85 to 90 percent of the earth that are not available in real time.

  18. Magnetic Tape Care, Storage, and Error Recovery.

    ERIC Educational Resources Information Center

    Schenck, Thomas

    1984-01-01

    Explains format of data on magnetic tape and process of reading and writing data to tape, and discusses sources of tape errors (physically damaged tape, unclean tape, magnetic alteration of data on tape, unclean or defective tape drive); correcting and/or bypassing tape errors; and care, storage, and shipment of tapes. (EJS)

  19. Magnet design with 100-kA HTS STARS conductors for the helical fusion reactor

    NASA Astrophysics Data System (ADS)

    Yanagi, N.; Terazaki, Y.; Ito, S.; Tamura, H.; Hamaguchi, S.; Mito, T.; Hashizume, H.; Sagara, A.

    2016-12-01

    The high-temperature superconducting (HTS) option is employed for the conceptual design of the LHD-type helical fusion reactor FFHR-d1. The 100-kA-class STARS (Stacked Tapes Assembled in Rigid Structure) conductor is used for the magnet system including the continuously wound helical coils. Protection of the magnet system in case of a quench is a crucial issue and the hot-spot temperature during an emergency discharge is estimated based on the zero-dimensional and one-dimensional analyses. The number of division of the coil winding package is examined to limit the voltage generation. For cooling the HTS magnet, helium gas flow is considered and its feasibility is examined by simple analysis as a first step.

  20. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  1. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  2. Evaluation of a strengthening and insulation system for high temperature BSCCO-2223 superconducting tape

    SciTech Connect

    King, C.; Mantone, A.; Herd, K.; Laskaris, T.

    1995-12-31

    Recent advances in BSCCO-2223 superconducting tape quality and length have led to demonstration programs for coil performance. The conductors in these coils need to be insulated without damage to the superconducting properties. A paper insulation process developed at the General Electric Company (GE) for low temperature superconducting Nb{sub 3}Sn tape has been modified to provide the same insulation system to high temperature (HTS) superconducting tapes, such as BSCCO-2223. In this paper, we report on the insulation process and its effect on the tape performance. Several long lengths of conductor have been tested, unwound, insulated and retested to examine any degradation issues. Additionally, it is known that HTS materials are inherently weak in relation to the winding and handling stresses in a manufacturing environment. A system to provide mechanical stabilization to Nb{sub 3}Sn tape through a lamination process has been successfully applied to high temperature superconductors as a method to build a strong, windable composite. The system is described and mechanical and electrical properties of the strengthened tapes are discussed.

  3. Duct Tape Durability Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2004-04-01

    Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

  4. Development of HTS Magnet for Rotating Gantry

    NASA Astrophysics Data System (ADS)

    Tasaki, Kenji; Koyanagi, Kei; Takayama, S. Shigeki; Ishii, Yusuke; Kurusu, Tsutomu; Amemiya, Naoyuki; Ogitsu, Toru; iwata, Yoshiyuki; Noda, Koji

    The effectiveness of heavy-ion radiotherapy for cancer treatment has been recognized by medical experts and the public. However, due to the large size of the equipment, this therapy has not been widely adopted. In particular, the rotating gantries used to irradiate patients with the heavy-ion beams from any direction may be as heavy as 600 tons in our estimation. By employing high-temperature superconducting (HTS) wires in these rotating gantries and increasing the magnetic field generated by the deflecting coils, the total weight of the rotating gantry can be reduced to around the weight of those used for proton radiotherapy. A project for developing an HTS deflecting magnet for heavy-ion radiotherapy has been underway since 2013, supported by the Japanese Ministry of Economy, Trade and Industry (METI) and the Japan Agency for Medical Research and Development (AMED). The aim of this project is to develop fundamental technologies for designing and fabricating HTS deflecting magnets, such as irregular magnetic field estimating techniques, design technology for HTS magnets, high-precision HTS coil winding technology, AC loss estimating techniques, and thermal runaway estimating techniques and to fabricate a small model of an HTS deflecting magnet and evaluate its performance. In this paper, the project's progress will be described.

  5. HTS Wire Development Workshop: Proceedings

    SciTech Connect

    Not Available

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  6. Cost Effective Open Geometry HTS MRI System amended to BSCCO 2212 Wire for High Field Magnets

    SciTech Connect

    Kennth Marken

    2006-08-11

    The original goal of this Phase II Superconductivity Partnership Initiative project was to build and operate a prototype Magnetic Resonance Imaging (MRI) system using high temperature superconductor (HTS) coils wound from continuously processed dip-coated BSCCO 2212 tape conductor. Using dip-coated tape, the plan was for MRI magnet coils to be wound to fit an established commercial open geometry, 0.2 Tesla permanent magnet system. New electronics and imaging software for a prototype higher field superconducting system would have added significantly to the cost. However, the use of the 0.2 T platform would allow the technical feasibility and the cost issues for HTS systems to be fully established. Also it would establish the energy efficiency and savings of HTS open MRI compared with resistive and permanent magnet systems. The commercial goal was an open geometry HTS MRI running at 0.5 T and 20 K. This low field open magnet was using resistive normal metal conductor and its heat loss was rather high around 15 kolwatts. It was expected that an HTS magnet would dissipate around 1 watt, significantly reduce power consumption. The SPI team assembled to achieve this goal was led by Oxford Instruments, Superconducting Technology (OST), who developed the method of producing commercial dip coated tape. Superconductive Components Inc. (SCI), a leading US supplier of HTS powders, supported the conductor optimization through powder optimization, scaling, and cost reduction. Oxford Magnet Technology (OMT), a joint venture between Oxford Instruments and Siemens and the world’s leading supplier of MRI magnet systems, was involved to design and build the HTS MRI magnet and cryogenics. Siemens Magnetic Resonance Division, a leading developer and supplier of complete MRI imaging systems, was expected to integrate the final system and perform imaging trials. The original MRI demonstration project was ended in July 2004 by mutual consent of Oxford Instruments and Siemens. Between

  7. Design of a Probe for Strain Sensitivity Studies of Critical Current Densities in SC Wires and Tapes

    SciTech Connect

    Dhanaraj, N.; Barzi, E.; Turrioni, D.; Rusy, A.; Lombardo, V.; /Fermilab

    2011-07-01

    The design of a variable-temperature probe used to perform strain sensitivity measurements on LTS wires and HTS wires and tapes is described. The measurements are intended to be performed at liquid helium temperatures (4.2 K). The wire or tape to be measured is wound and soldered on to a helical spring device, which is fixed at one end and subjected to a torque at the free end. The design goal is to be able to achieve {+-} 0.8 % strain in the wire and tape. The probe is designed to carry a current of 2000A.

  8. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  9. Experimental investigations on the soldering performances of the joints for Bi-2223/Ag tapes

    NASA Astrophysics Data System (ADS)

    Zou, Chunlong; Son, Yuntao; Huang, Xiongyi; Liu, Chenglian; Khan, Shahab Ud-Din; Weibin, Xi; Kun, Lu

    2015-01-01

    In this paper, we have fabricated Bi-2223/Ag jointed tapes and evaluated its joint resistance at liquid nitrogen temperature (77 K). The tapes were joined by the conventional resistive joint method using five kinds of solders with different melting points. The lower melting point Bi-Sn-Pb and high melting point Sn-Ag-Cu solders have lower joint resistances. In addition, two different joining processes were compared by joining the copper sheet. The joint resistances were measured at lower temperature and the resistance appears comparable to each other. It indicated that the direct-jointing is more effective method for high temperature superconductor (HTS) joining.

  10. Microstructure dependence of the c-axis critical current density in second generation YBCO tapes

    SciTech Connect

    Jia, Y. Welp, U. Crabtree, G.W.; Kwok, W.K.; Malozemoff, A.P.; Rupich, M.W.; Fleshler, S.; Clem, J.R.

    2011-10-31

    C-axis current flow in high temperature superconductor (HTS) tape-shaped wires arises in configurations where the local wire axis is not perpendicular to the local magnetic field, such as in power cables with helically wound HTS tapes. The c-axis critical current density J{sub c}{sup c} has been recently found to be orders of magnitude lower than the ab-plane critical current density J{sub c}{sup ab}. Here we report on J{sub c}{sup c} (77 K, sf) values of various YBa{sub 2}Cu{sub 3}O{sub 7}-based (YBCO) tapes with different microstructures. Our results show that the value of J{sub c}{sup c} (77 K, sf) decreases significantly with increasing concentration of ab-plane stacking faults in YBCO thin films and that the critical current anisotropy {gamma} = J{sub c}{sup ab}/J{sub c}{sup c} can reach values as high as 2070, implying that in the highest-anisotropy tape, {approx}20% of the tape width carries c-axis current in a helically wound power cable.

  11. Microstructure dependence of the c-axis critical current density in second-generation YBCO tapes.

    SciTech Connect

    Jia, Y.; Welp, U.; Crabtree, G. W.; Kwok, W. K.; Malozemoff, A. P.; Rupich, M. W.; Fleshler, S.; Clem, J. R.

    2011-10-01

    C-axis current flow in high temperature superconductor (HTS) tape-shaped wires arises in configurations where the local wire axis is not perpendicular to the local magnetic field, such as in power cables with helically wound HTS tapes. The c-axis critical current density J{sub c}{sup c} has been recently found to be orders of magnitude lower than the ab-plane critical current density J{sub c}{sup ab}. Here we report on J{sub c}{sup c} (77 K, sf) values of various YBa{sub 2}Cu{sub 3}O{sub 7}-based (YBCO) tapes with different microstructures. Our results show that the value of J{sub c}{sup c} (77 K, sf) decreases significantly with increasing concentration of ab-plane stacking faults in YBCO thin films and that the critical current anisotropy {gamma} = J{sub c}{sup ab}/J{sub c}{sup c} can reach values as high as 2070, implying that in the highest-anisotropy tape, {approx}20% of the tape width carries c-axis current in a helically wound power cable.

  12. Development of an HTS hydroelectric power generator for the hirschaid power station

    NASA Astrophysics Data System (ADS)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  13. R&D ERL: HTS Solenoid

    SciTech Connect

    Gupta, R.; Muratore, J.; Plate, S.

    2010-01-01

    An innovative feature of the ERL project is the use of a solenoid made with High Temperature Superconductor (HTS) with the Superconducting RF cavity. The HTS solenoid design offers many advantages because of several unique design features. Typically the solenoid is placed outside the cryostat which means that the beam gets significantly defused before a focusing element starts. In the current design, the solenoid is placed inside the cryostat which provides an early focusing structure and thus a significant reduction in the emittance of the electron beam. In addition, taking full advantage of the high critical temperature of HTS, the solenoid has been designed to reach the required field at {approx}77 K, which can be obtained with liquid nitrogen. This significantly reduces the cost of testing and allows a variety of critical pre-tests which would have been prohibitively expensive at 4 K in liquid helium because of the additional requirements of cryostat and associated facilities.

  14. The Mechanical Design Optimization of a High Field HTS Solenoid

    SciTech Connect

    Lalitha, SL; Gupta, RC

    2015-06-01

    This paper describes the conceptual design optimization of a large aperture, high field (24 T at 4 K) solenoid for a 1.7 MJ superconducting magnetic energy storage device. The magnet is designed to be built entirely of second generation (2G) high temperature superconductor tape with excellent electrical and mechanical properties at the cryogenic temperatures. The critical parameters that govern the magnet performance are examined in detail through a multiphysics approach using ANSYS software. The analysis results formed the basis for the performance specification as well as the construction of the magnet.

  15. Operational experience in the use of 18 kA HTS current leads for Edipo

    NASA Astrophysics Data System (ADS)

    March, S.; Wesche, R.; Bruzzone, P.

    2014-05-01

    In spring 2013, the Edipo facility of CRPP was commissioned. The dipole is powered via two 18 kA HTS current leads, designed and manufactured at CRPP. As part of the Edipo commissioning framework, the operational parameters of the leads were implemented in the control system. The in-situ tests were found to be in good agreement with the tests performed without a background field in 2011. The leads consist of a conduction cooled HTS module, made of AgMgAu/Bi-2223 stacks, and a wire bundle heat exchanger. The heat exchanger is cooled by forced flow helium gas, the inlet temperature of which was measured to vary between 65 K and 85 K. During operation with field, the mass flow rate is a function of current (2.05 g/s per lead at full field, 12.35 T, 17.2 kA). Reduced cooling investigations showed that 0.31 g/s per lead is suitable for overnight standby and 0.2 g/s per lead for longer periods. For detection of and protection against quench in the HTS module, a threshold of 10 mV was found to be appropriate. The heat exchanger has a voltage protection threshold of 120 mV. The temperatures of the heat exchanger, the HTS, and the helium inlet temperature were monitored in order to provide a further layer of protection.

  16. US effort on HTS power transformers

    NASA Astrophysics Data System (ADS)

    Mehta, S.

    2011-11-01

    Waukesha Electric Systems has been working in HTS power transformers development program under the auspices of US Government Department of Energy since 1994. This presentation will describe various milestones for this program and program history along with the lessons learned along the way. Our motivations for working on this development program based on man benefits offered by HTS power transformers to power delivery systems will be discussed. Based on various issues encountered during execution of many HTS projects, DOE has set up an independent program review process that is lead by team of experts. This team reviews are integral part of all DOE HTS projects. Success of all projects would be greatly enhanced by identifying critical issues early in the program. Requiring appropriate actions to mitigate the issues before processing further will lead to proactive interrogation and incorporation of expert's ideas in the project plans. Working of this review process will be also described in this presentation. Waukesha Electric Systems team including: Superpower-Inc, Oak Ridge National Laboratory, University of Houston Center for Superconductivity and Southern California Edison company was awarded a cost share grant by US Government in 2010 for development of a fault current limiting HTS power transformer. This multi year's program will require design, manufacture, installation, and monitoring of a 28 MVA tree phase transformer installed at Irvine CA. Smart Grid demonstration site. Transformer specifications along with requirements for fault current limiting and site requirement will be discussed. Design and development of various sub systems in support of this program including: HTS conductor performance specification, Dielectric system design approach, Dewar development for containing phase assemblies, cryo-cooling system design approach, etc. will be described. Finally; overall program schedule, critical milestone events, test plans and progress to date will be

  17. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  18. Modeling AC ripple currents in HTS coated conductors by integral equations

    NASA Astrophysics Data System (ADS)

    Grilli, Francesco; Xu, Zhihan

    2016-12-01

    In several HTS applications, the superconducting tapes experience the simultaneous presence of DC and AC excitations. For example in high-current DC cables, where the transport current is not perfectly constant, but it exhibits some ripples at different frequencies introduced by the rectification process (AC-DC conversion). These ripples give rise to dissipation, whose magnitude and possible influence on the device's cooling requirements need to be evaluated. Here we report a study of the AC losses in a HTS coated conductor subjected to DC currents and AC ripples simultaneously. The modeling approach is based on an integral equation method for thin superconductors: the superconducting tape is modeled as a 1-D object with a non-linear resistivity, which includes the dependence of the critical current density Jc on the magnetic field. The model, implemented in a commercial finite-element program, runs very fast (the simulation of one AC cycle typically takes a few seconds on standard desktop workstation): this allows simulating a large number of cycles and estimating when the AC ripple losses stabilize to a constant value. The model is used to study the influence of the flux creep power index n on the stabilization speed and on the AC loss values, as well as the effect of using a field-dependent Jc instead of a constant one. The simulations confirm that the dissipation level should not be a practical concern in HTS DC cables. At the same time, however, they reveal a strong dependence of the results upon the power index n and the form of Jc , which spurs the question whether the power-law is the most suitable description of the superconductor's electrical behavior for this kind of analysis.

  19. Tape Dump and Restore.

    DTIC Science & Technology

    1980-08-28

    VM/ CMS as provided at Virginia Tech and to make it possible to transfer files from this system to other computer systems , possibly machines using the...Technical Memorandum No. 80-5 DTI(-C August 28, 1980 DEC T.77w S DEC23 1980 F ABSTRACT A set of three programs to write CMS disk files on magnetic...tape in a variety of formats suitable for reading on a variety of computing systems and for restoring these tape files to disk within the restrictions

  20. Predictive 1-D thermal-hydraulic analysis of the prototype HTS current leads for the ITER correction coils

    NASA Astrophysics Data System (ADS)

    Heller, R.; Bauer, P.; Savoldi, L.; Zanino, R.; Zappatore, A.

    2016-12-01

    We present an analysis of the prototype high-temperature superconducting (HTS) current leads (CLs) for the ITER correction coils, which will operate at 10 kA. A copper heat exchanger (HX) of the meander-flow type is included in the CL design and covers the temperature range between room temperature and 65 K, whereas the HTS module, where Bi-2223 stacked tapes are positioned on the outer surface of a stainless steel hollow cylindrical support, covers the temperature range between 65 K and 4.5 K. The HX is cooled by gaseous helium entering at 50 K, whereas the HTS module is cooled by conduction from the cold end of the CL. We use the CURLEAD code, developed some years ago and now supplemented by a new set of correlations for the helium friction factor and heat transfer coefficient in the HX, recently derived using Computational Fluid Dynamics. Our analysis is aimed first of all at a "blind" design-like prediction of the CL performance, for both steady state and pulsed operation. In particular, the helium mass flow rate needed to guarantee the target temperature at the HX-HTS interface, the temperature profile, and the pressure drop across the HX will be computed. The predictive capabilities of the CURLEAD model are then assessed by comparison of the simulation results with experimental data obtained in the test of the prototype correction coil CLs at ASIPP, whose results were considered only after the simulations were performed.

  1. Current Bypassing Properties by Thermal Switch for PCS Application on NMR/MRI HTS Magnets

    NASA Astrophysics Data System (ADS)

    Kim, S. B.; Takahashi, M.; Saito, R.; Park, Y. J.; Lee, M. W.; Oh, Y. K.; Ann, H. S.

    We develop the compact NMR/MRI device using high temperature superconducting (HTS) wires with the persistent current mode operating. So, the joint techniques between 2G wires are very important issue and many studies have been carried out. Recently, the Kbigdot JOINS, Inc. has developed successfully the high performance superconducting joints between 2G wires by partial melting diffusion and oxygenation annealing process [1]. In this study, the current bypassing properties in a loop-shaped 2G wire are measured experimentally to develop the permanent current switch (PSC). The current bypassing properties of loop-shaped test coil wound with 2G wire (GdBCO) are evaluated by measured the self-magnetic field due to bypassed current by Hall sensors. The strain gauge was used as heater for persistent current switch, and thermal properties against various thermal inputs were investigated experimentally.

  2. Development of a brushless HTS exciter for a 10 kW HTS synchronous generator

    NASA Astrophysics Data System (ADS)

    Bumby, Chris W.; Badcock, Rodney A.; Sung, Hae-Jin; Kim, Kwang-Min; Jiang, Zhenan; Pantoja, Andres E.; Bernardo, Patrick; Park, Minwon; Buckley, Robert G.

    2016-02-01

    HTS synchronous generators, in which the rotor coils are wound from high-T c superconducting wire, are exciting attention due to their potential to deliver very high torque and power densities. However, injection of the large DC currents required by the HTS rotor coils presents a technical challenge. In this paper we discuss the development of a brushless HTS exciter which operates across the cryostat wall to inject a superconducting DC current into the rotor coil circuit. This approach fundamentally alters the thermal load upon the cryogenic system by removing the need for thermally inefficient normal-conducting current leads. We report results from an experimental laboratory device and show that it operates as a constant voltage source with an effective internal resistance. We then discuss the design of a prototype HTS-PM exciter based on our experimental device, and describe its integration with a demonstration HTS generator. This 200 RPM, 10 kW synchronous generator comprises eight double pancake HTS rotor coils which are operated at 30 K, and are energised to 1.5 T field through the injection of 85 A per pole. We show how this excitation can be achieved using an HTS-PM exciter consisting of 12 stator poles of 12 mm YBCO coated-conductor wire and an external permanent magnet rotor. We demonstrate that such an exciter can excite the rotor windings of this generator without forming a thermal-bridge across the cryostat wall. Finally, we provide estimates of the thermal load imposed by our prototype HTS-PM exciter on the rotor cryostat. We show that duty cycle operation of the device ensures that this heat load can be minimised, and that it is substantially lower than that of equivalently-rated conventional current leads.

  3. Safety brake for tape reels

    NASA Technical Reports Server (NTRS)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  4. A Test of HTS Power Cable in a Sweeping Magnetic Field

    SciTech Connect

    Piekarz, H.; Hays, S.; Blowers, J.; Shiltsev, V.; /Fermilab

    2011-11-29

    Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s ramping rate. The B-field orientation toward the HTS strands wide surface was varied from 0{sup 0} to 10{sup 0}, in steps of 1{sup 0}. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. For the validity of these measurements, the power losses of a short sample cable composed of multiple LTS wire strands were also performed to compare with the known data. The test arrangement of the power cable is described, and the test results are compared with the projections for the eddy and hysteresis power losses using the fine details of the test cable structures.

  5. Alternating current loss characteristics in (bismuth,lead)SCCO and yttrium barium copper oxide superconducting tapes

    NASA Astrophysics Data System (ADS)

    Nguyen, Doan Ngoc

    Alternating current (AC) loss and current carrying capacity are two of the most crucial considerations in large-scale power applications of high temperature superconducting (HTS) conductors. AC losses result in an increased thermal load for cooling machines, and thus increased operating costs. Furthermore, AC losses can stimulate quenching phenomena or at least decrease the stability margin for superconducting devices. Thus, understanding AC losses is essential for the development of HTS AC applications. The main focus of this dissertation is to make reliable total AC loss measurements and interpret the experimental results in a theoretical framework. With a specially designed magnet, advanced total AC loss measurement system in liquid nitrogen (77 K) has been successfully built. Both calorimetric and electromagnetic methods were employed to confirm the validity of the measured results and to have a more thorough understanding of AC loss in HTS conductors. The measurement is capable of measuring total AC loss in HTS tapes over a wide range of frequency and amplitude of transport current and magnetic field. An accurate phase control technique allows measurement of total AC loss with any phase difference between the transport current and magnetic field by calorimetric method. In addition, a novel total AC loss measurement system with variable temperatures from 30 K to 100 K was successfully built and tested. Understanding the dependence of AC losses on temperature will enable optimization of the operating temperature and design of HTS devices. As a part of the dissertation, numerical calculations using Brandt's model were developed to study electrodynamics and total AC loss in HTS conductors. In the calculations, the superconducting electrical behavior is assumed to follow a power-law model. In general, the practical properties of conductors, including field-dependence of critical current density Jc, n-value and non-uniform distribution of Jc, can be accounted for in

  6. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  7. Tamper tape seals

    SciTech Connect

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R&D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique {open_quotes}fingerprint{close_quotes} characteristics that can be accessed as desired.

  8. Mobile conduction-cooled HTS SMES

    NASA Astrophysics Data System (ADS)

    Ren, L.; Tang, Y.; Li, J.; Shi, J.; Chen, L.; Guo, F.; Fang, J.; Wen, J.

    2010-11-01

    An immovable 35 kJ/7 kW high-Tc superconducting magnetic energy storage (HTS SMES) system had been developed in the Electric Power System Dynamic Simulation Laboratory, Huazhong University of Science and Technology in 2005. In order to adapt for on-site experimental conditions, the mechanical configuration of the magnet is reinforced and the SMES system is assembled in a special container to be freighted to the actual power system for the feasibility study on different applications at different sites. The mobile HTS SMES system had withstood various kinds of poor road surfaces and then arrived at the experimental site on August 18, 2009. In this paper, the reconstructed configuration and the shock absorption of the magnet are presented. The field test results show that the mobile SMES system can operate on the power network at different locations and suppress effectively power fluctuation of the generator terminal.

  9. Image processing for HTS SQUID probe microscope

    NASA Astrophysics Data System (ADS)

    Hayashi, T.; Koetitz, R.; Itozaki, H.; Ishikawa, T.; Kawabe, U.

    2005-10-01

    An HTS SQUID probe microscope has been developed using a high-permeability needle to enable high spatial resolution measurement of samples in air even at room temperature. Image processing techniques have also been developed to improve the magnetic field images obtained from the microscope. Artifacts in the data occur due to electromagnetic interference from electric power lines, line drift and flux trapping. The electromagnetic interference could successfully be removed by eliminating the noise peaks from the power spectrum of fast Fourier transforms of line scans of the image. The drift between lines was removed by interpolating the mean field value of each scan line. Artifacts in line scans occurring due to flux trapping or unexpected noise were removed by the detection of a sharp drift and interpolation using the line data of neighboring lines. Highly detailed magnetic field images were obtained from the HTS SQUID probe microscope by the application of these image processing techniques.

  10. First Russian long length HTS power cable

    NASA Astrophysics Data System (ADS)

    Volkov, Eduard P.; Vysotsky, Vitaly S.; Firsov, Valery P.

    2012-11-01

    The Russian R&D Program for superconducting power devices is underway, supported both by government and electric power companies. In this program R&D on HTS power cables is considered as most advanced and close to commercialization. In the framework of the program, several, heavily instrumented, 5 m cables have been tested following by the 30 m - 3 phase experimental power cable development and testing in 2008-2009. The latest achievement is development and testing of the first long length 3 × 200 m power cable with rating 1.5/2 kA-20 kV. In parallel with just the cable development the innovative cryogenic system has been developed as well for the cable cooling. The system is using neon as working substance and radial turbo-machines in refrigerator. Cooling power is up to ∼8 kW at 65 K, inter-maintenance time ∼30,000 h. The cryogenic pump with superconducting motor can be used to provide subcooled liquid nitrogen flow ∼0.1-1.5 kg/s at 0.1-2.5 MPa pressure. After extensive tests at special test facility, HTS power cable and cryogenic system are planning to be installed at some substation in Moscow utility grid. In this review some details about Russian HTS power application program, 200 m cable and cryogenic system designs and tests results are presented.

  11. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  12. THE UTILIZATION OF THE NTP-HTS DATA IN CHEMICAL ...

    EPA Pesticide Factsheets

    To explore efficient approaches to assessing the toxicity of environmental chemicals, the NIEHS National Toxicology Program (NTP) recently initiated a High Throughput Screening (HTS) Project. To date, HTS results for a set of 1,408 compounds tested in 6 cell viability assays have been released via PubChem. This abstract explores herein the utility of the HTS data for predicting animal and human toxicity. To explore efficient approaches to assessing the toxicity of environmental chemicals, the NIEHS National Toxicology Program (NTP) recently initiated a High Throughput Screening (HTS) Project. To date, HTS results for a set of 1,408 compounds tested in 6 cell viability assays have been released via PubChem. This abstract explores herein the utility of the HTS data for predicting animal and human toxicity.

  13. Two applications of HTS technology on an airborne platform

    SciTech Connect

    Robertson, M.A.

    1994-12-31

    This paper describes two applications for HTS technology on an airborne platform. The first application is a RF front-end for an 8 to 40 GHz microwave/ millimeter-wave ESM system. The second application is a 2 to 4 GHz HTS Spiral Antenna Array System. The HTS microwave front-end unit consists of an HTS diplexer, and two low noise preamplifiers. The design demonstrates the benefits of HTS technology while providing a near-term insertion on a military airborne platform. The HTS Spiral Antenna Array System utilizes a 4 element conical spiral array (conventional technology) and a beamforming network consisting of a HTS power combiner, a HTS bandpass filter, HTS coupler, and a conventional technology low noise preamplifier. Both applications utilize low insertion loss HTS devices coupled with the cryogenic cooling of conventional low noise preamplifiers to lower the overall noise figure of the systems. The HTS Spiral Antenna Array System provides a 3 dB improvement in SNR over the best available conventional technology system. A 3 dB improvement in SNR can be compared to the doubling of the antenna aperture which provides a 3 dB gain increase, but at the expense of a decreased field of view. A 3 dB increase in SNR can also be viewed as a 41% increase in usable target range. The HTS antenna system maintains a wide field of view with a performance that approaches a steerable beam antenna. This is a cost effective approach for improving the collection capability of a system without the expense of developing a steerable beam antenna and the associated beam control hardware (tracker) and software.

  14. Magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.; Jafferis, W.

    1980-01-01

    Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

  15. High output power electric motors with bulk HTS elements

    NASA Astrophysics Data System (ADS)

    Kovalev, L. K.; Ilushin, K. V.; Kovalev, K. L.; Penkin, V. T.; Poltavets, V. N.; Koneev, S. M.-A.; Akimov, I. I.; Gawalek, W.; Oswald, B.; Krabbes, G.

    2003-04-01

    New types of electric machines with the rotors containing bulk HTS (YBCO and Bi-Ag) elements are presented. Different schematics of hysteresis, reluctance, “trapped field” and composed synchronous HTS machines are discussed. The two-dimensional mathematical models describing the processes in such types of HTS machines were developed on the basis of the theoretical analysis of the electrodynamic and hysteresis processes in the single-domain and polycrystal YBCO ceramic samples and plate shape Bi-Ag elements. The test results of the series of hysteresis, reluctance, “trapped field” and composed with permanent magnets HTS motors with output power rating 0.1-18 kW and current frequency 50 and 400 Hz are given. These results show that in the media of liquid nitrogen the specific output power per one weight unit of HTS motors is 4-7 times better than for conventional electric machines. Comparison of the theoretical and experimental characteristics of the developed HTS motors show that they are in good agreement. The test results for liquid nitrogen cryogenic pump system with hysteresis 500 W HTS motor are discussed. The designs and first test results of HTS motor operating in the media of liquid nitrogen with output power 100 kW and power factor more than 0.8 are given. Future development and applications of new types of HTS motors for aerospace technology, on-land industry and transport systems are discussed.

  16. Superconducting Electric Machine with Permanent Magnets and Bulk HTS Elements

    NASA Astrophysics Data System (ADS)

    Levin, A. V.; Vasich, P. S.; Dezhin, D. S.; Kovalev, L. K.; Kovalev, K. L.; Poltavets, V. N.; Penkin, V. T.

    Theoretical methods of calculating of two-dimensional magnetic fields, inductive parameters and output characteristics of the new type of high-temperature superconducting (HTS) synchronous motors with a composite rotor are presented. The composite rotor has the structure containing HTS flat elements, permanent magnets and ferromagnetic materials. The developed calculation model takes into account the concentrations and physical properties of these rotor elements. The simulation results of experimental HTS motor with a composite rotor are presented. The application of new type of HTS motor in different constructions of industrial high dynamic drivers is discussed.

  17. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  18. Pillows and Tape.

    PubMed

    Mand, Parandeep; Miller, Kevin M

    2010-03-09

    A 76-year-old man with a severe neck deformity resulting in a facedown posture presented with a visually significant cataract in his right eye. The patient had been scheduled for cataract surgery elsewhere, but the surgery was cancelled in the operating room when he could not be positioned beneath the operating microscope. The patient's surgery was safely and effectively performed by placing 25 to 30 pillows under his buttocks and legs and one pillow and a towel beneath his head and neck. The patient and pillows were taped to the operating table so that they would not move.

  19. Multifilamentary niobium tin superconductor tape

    NASA Technical Reports Server (NTRS)

    Brisbin, P. H.; Coles, W. D.

    1975-01-01

    In the method proposed for fabricating multifilamentary Nb3Sn tape, filamentary superconducting paths are produced in standard commercial superconductor tape by chemical milling of separator slots through the Nb3Sn layer. The multifilament configuration features a matrix of ten 1.2 mm wide parallel helical superconducting paths along the length of the tape. The paths are spaced 0.4 mm apart. Tapes tested as small pancake coils demonstrated the integrity and continuity of the matrix, and showed that critical current was sustained in direct proportion to retained superconductor.

  20. Tape casting of magnesium oxide.

    SciTech Connect

    Ayala, Alicia; Corral, Erica L.; Loehman, Ronald E.; Bencoe, Denise Nora; Reiterer, Markus; Shah, Raja A.

    2008-02-01

    A tape casting procedure for fabricating ceramic magnesium oxide tapes has been developed as a method to produce flat sheets of sintered MgO that are thin and porous. Thickness of single layer tapes is in the range of 200-400 {micro}m with corresponding surface roughness values in the range of 10-20 {micro}m as measured by laser profilometry. Development of the tape casting technique required optimization of pretreatment for the starting magnesium oxide (MgO) powder as well as a detailed study of the casting slurry preparation and subsequent heat treatments for sintering and final tape flattening. Milling time of the ceramic powder, plasticizer, and binder mixture was identified as a primary factor affecting surface morphology of the tapes. In general, longer milling times resulted in green tapes with a noticeably smoother surface. This work demonstrates that meticulous control of the entire tape casting operation is necessary to obtain high-quality MgO tapes.

  1. Design of Conduction-cooled HTS Coils for a Rotating Gantry

    NASA Astrophysics Data System (ADS)

    Takayama, Shigeki; Koyanagi, Kei; Yamaguchi, Akiko; Tasaki, Kenji; Kurusu, Tsutomu; Ishii, Yusuke; Amemiya, Naoyuki; Ogitsu, Toru; Noda, Koji

    Carbon ion cancer therapy is becoming more widespread due to its high curative effects and low burden on patients. Carbon ions are delivered to patients through electromagnets on a rotating gantry.A rotating gantry is attractive because it allows carbon ions to irradiate a tumor from any direction without changing the posture of the patient. On the other hand, because of the high magnetic rigidity of carbon ions, the weight of a rotating gantry for carbon cancer therapy is about three times higher than one for proton cancer therapy, according to our estimation. The use of high-temperature superconducting (HTS) magnets has been considered for reducing the size of the rotating gantry for carbon cancer therapy. The target weight is 200 t or less,which is equivalent to the weight of a typical rotating gantry for proton cancer therapy.In this study, the magnet layout of the rotating gantry and the superconducting magnets were designed from the viewpoint of beam optics.When applying high-temperature superconductors to accelerator magnets, there are some issues that should be considered, for example, the influence of tape magnetization and manufacturing accuracy on the field quality, the thermal stability of the conduction-cooled HTS coils under an alternating magnetic field, and methods to protect the coils from thermal runaway caused by an anomalous thermal input such as that due to beam loss. First, the thermal stability of the conduction-cooled HTS coils was simulated numerically, and the thermal runaway current was calculated in a static situation.

  2. Development of HTS-SQUID Gradiometer with an External HTS Multiturn Thin Film Pickup Coil

    NASA Astrophysics Data System (ADS)

    Teraoka, M.; Tsukamoto, A.; Adachi, S.; Takai, H.; Tanabe, K.

    Highly-sensitive HTS-SQUIDs are applied to various systems such as eddy-current non-destructive evaluation (NDE) and compact magnetometer systems. To avoid unstable operation of the SQUID due to an excitation field, a flux transformer made of normal Cu wire is used to separate the pickup coil and SQUID. However, the resistance of the flux transformer generates thermal noise and reduces the signal bandwidth at low frequencies. In this study, we investigate use of a superconducting flux transformer with resistive connections (SFTR). The SFTR consists of pickup and input coils made of HTS thin films. The two coils are connected by using an HTS coated conductor. The input coil is stacked on an HTS thin film gradiometer. From the measured results of resistances of the connections between each coil and the coated conductor, it was found that the resistance of bonding wire was a dominant component. The estimated resistance of the SFTR was 7.2 mΩ, corresponding to a lower cut-off frequency of 11.7 Hz.

  3. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    SciTech Connect

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  4. Thermal analysis for the HTS stator consisting of HTS armature windings and an iron core for a 2.5 kW HTS generator

    NASA Astrophysics Data System (ADS)

    Song, P.; Qu, T.-M.; Lai, L.-F.; Wu, M.-S.; Yu, X.-Y.; Han, Z.

    2016-05-01

    Most present demonstrations of high-temperature superconducting (HTS) synchronous motors/generators are partially superconducting, only installing HTS coils on the rotor as excitation windings. The possible applicability of HTS armature windings is an interesting research topic because these windings can certainly increase the power density attributed to a potentially high armature loading capacity. In this study, we analysed the thermal behaviours of a developed 2.5 kW-300 rpm synchronous generator prototype that consists of an HTS stator with Bi-2223-Ag armature windings on an iron core and a permanent magnet (PM) rotor. The entire HTS stator, including the iron core, is cooled with liquid nitrogen through conduction cooling. The rated frequency is set at 10 Hz to reduce AC loss. The properties of the HTS windings and the iron core are characterized, and the temperatures in the HTS stator under different operation conditions are measured. The estimated iron loss is 11.5 W under operation in 10 Hz at liquid nitrogen temperature. Conduction cooling through the silicon iron core is sufficient to cool the iron core and to compensate for the temperature increment caused by iron loss. The stable running capacity is limited to 1.6 kW when the armature current is 12.6 A (effective values) due to the increasing temperature in the slots as a result of the AC loss in the HTS coils. The thermal contact between the HTS coils and the cooling media should be improved in the future to take away the heat generated by AC loss.

  5. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  6. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  7. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  8. Book Selection from MARC Tapes.

    ERIC Educational Resources Information Center

    Wainwright, Jane; Hills, Jacqueline

    In April 1971 the Aslib Research and Development Department began a study on selective dissemination from MARC tapes. The aim of the project was to explore the technical and economic feasibility of providing selective notifications of current books, by extraction from MARC tapes, to specialized libraries. Typical of the potential customers…

  9. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  10. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides…

  11. Tape-Smoothing Tool For Adhesion Tests

    NASA Technical Reports Server (NTRS)

    Allen, Peter B.

    1992-01-01

    Small tool smoothes adhesive tape uniformly to ensure consistency and repeatability of tape-peel tests of adhesion of paint to substrate. Includes resilient pad covered with tough, smooth fabric. Internal spring regulates force applied to tape.

  12. THE USE OF NTP-HTS DATA FOR PREDICTIVE ...

    EPA Pesticide Factsheets

    To explore efficient approaches to assessing the toxicity of envoronmental chemicals, the NIEHS National Toxicology Program (NTP) recently initiated a High Throughput Screening (HTS) Project. To explore efficient approaches to assessing the toxicity of envoronmental chemicals, the NIEHS National Toxicology Program (NTP) recently initiated a High Throughput Screening (HTS) Project.

  13. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  14. Comparison between Bi-2223 tape and RE-123 coated conductor from the view point of current transport properties influencing thermal stability

    NASA Astrophysics Data System (ADS)

    Kiss, Takanobu; Inoue, Masayoshi; Higashikawa, Kohei; Suzuki, Takumi; Lyu, Lin; Takasaki, Ken; Imamura, Kazutaka; Onodera, Yuta; Uetsuhara, Dai; Ibi, Akira; Izumi, Teruo; Kitaguchi, Hitoshi

    2016-12-01

    We have investigated flux flow dissipation in typical two kinds of HTS tapes, i.e., a Bi-2223 multi-filamentary tape and a RE-123 coated conductor (CC) from the view point of heat load under over current conditions. Based on systematic measurements on current-voltage characteristics, the nonlinear flux flow dissipation has been described analytically by taking into account current sharing in metallic sheath or stabilization layer. Flux flow dissipation in the RE-123 CC shows much steeper temperature dependence than that of the Bi-2223 tape. As a result, attainable cooling power becomes smaller in the RE-123 CC in comparison with that of Bi-2223 tape even if the same cooling condition. In other word, acceptable temperature rise in the RE-123 CC is small at over current condition, whereas moderate temperature dependence in the Bi-2223 tape allows stable operation even if the bias current exceeds the critical current. Influence of spatial inhomogeneity in the both HTS tapes has also been investigated. Longitudinal variation of local critical current, Ic, and its statistical behavior have been characterized by use of reel-to-reel scanning Hall probe microscopy. It has been found that the flux flow dissipation is possibly localized more than one order higher than that of the average value due to discrete local Ic drops.

  15. International Workshop on Cooling-system for HTS Applications 2015 (IWC-HTS 2015) 14-16 October 2015

    NASA Astrophysics Data System (ADS)

    Kamioka, Yasuharu

    2016-12-01

    International Workshop on Cooling-system for HTS Applications 2015 (IWC-HTS 2015) was held on 14-16 October 2015 at Kunibiki Messe (Shimane Prefectural Convention Center), Matsue, Shimane, Japan. The workshop was organized by the local committee on behalf of Cryogenics and Superconductivity Society of Japan (CSSJ).

  16. Method of forming an HTS article

    DOEpatents

    Bhattacharya, Raghu N.; Zhang, Xun; Selvamanickam, Venkat

    2014-08-19

    A method of forming a superconducting article includes providing a substrate tape, forming a superconducting layer overlying the substrate tape, and depositing a capping layer overlying the superconducting layer. The capping layer includes a noble metal and has a thickness not greater than about 1.0 micron. The method further includes electrodepositing a stabilizer layer overlying the capping layer using a solution that is non-reactive to the superconducting layer. The superconducting layer has an as-formed critical current I.sub.C(AF) and a post-stabilized critical current I.sub.C(PS). The I.sub.C(PS) is at least about 95% of the I.sub.C(AF).

  17. Electromagnetic properties of Bi-2223/Ag concentric tapes

    SciTech Connect

    Majoros, M.; Polak, M.; Kvitkovic, J.; Suchon, D.; Martini, L.; Ottoboni, V.; Zannella, S.

    1996-07-01

    It is well established that near the silver interface highly textured Bi-2223 layers compared to the inner ceramic core may be obtained. Thus Bi-2223 multilayered concentric tapes with silver matrix are very promising in increasing transport critical current densities. In the present work the authors report on the electromagnetic characterization of short tapes having in their cross-section a very thin HTS flattened ring with Ag inside and outside of it. The samples were prepared by the powder in tube method and have self-field critical current densities J{sub c} of the order of 3 {times} 10{sup 4} A/cm{sup 2} at 77 K. Transport and SQUID magnetization measurements revealed weak link nature of the samples in low magnetic fields. Large transport J{sub c}(B) hysteresis was observed at 4.2 K and magnetic fields up to 20 T. Magnetic field profiles measurements with miniature Hall sensors are in qualitative accordance with model calculations supposing homogeneous current density distribution across the superconducting core.

  18. Modeling and simulation of HTS cables for scattering parameter analysis

    NASA Astrophysics Data System (ADS)

    Bang, Su Sik; Lee, Geon Seok; Kwon, Gu-Young; Lee, Yeong Ho; Chang, Seung Jin; Lee, Chun-Kwon; Sohn, Songho; Park, Kijun; Shin, Yong-June

    2016-11-01

    Most of modeling and simulation of high temperature superconducting (HTS) cables are inadequate for high frequency analysis since focus of the simulation's frequency is fundamental frequency of the power grid, which does not reflect transient characteristic. However, high frequency analysis is essential process to research the HTS cables transient for protection and diagnosis of the HTS cables. Thus, this paper proposes a new approach for modeling and simulation of HTS cables to derive the scattering parameter (S-parameter), an effective high frequency analysis, for transient wave propagation characteristics in high frequency range. The parameters sweeping method is used to validate the simulation results to the measured data given by a network analyzer (NA). This paper also presents the effects of the cable-to-NA connector in order to minimize the error between the simulated and the measured data under ambient and superconductive conditions. Based on the proposed modeling and simulation technique, S-parameters of long-distance HTS cables can be accurately derived in wide range of frequency. The results of proposed modeling and simulation can yield the characteristics of the HTS cables and will contribute to analyze the HTS cables.

  19. Waveform control pulse magnetization for HTS bulk magnet

    NASA Astrophysics Data System (ADS)

    Ida, Tetsuya; Shigeuchi, Koji; Okuda, Sayo; Watasaki, Masahiro; Izumi, Mitsuru

    2016-03-01

    For the past 10 years, we have studied high-temperature superconducting (HTS) bulk magnets for use in electromagnetic rotating machines. If the magnetic field effectively magnetizes the HTS bulk, then the size of the motor and generator can be reduced without a reduction in output. We showed that the melt-textured Gd-Ba-Cu-O HTS bulk effectively traps a high magnetic field using waveform control pulse magnetization (WCPM). WCPM makes it possible to generate any pulsed magnetic field waveform by appropriately changing the duty ratio of the pulse width modulation. By chopping so that the pulsed magnetic field has a period of about 1ms, the WCPM technology enables active control of the rise time and suppresses magnetic flux motion that decreases magnetization efficiency. This method is also useful for any HTS bulk magnet, and the high magnetic flux density is trapped in the HTS bulk by a single pulse magnetic field. We developed a magnetizer that has a feedback system from the penetrated magnetic flux density to realize WCPM. In this research, using only a single pulse magnetic field of WCPM method at 77K, an HTS bulk with a 45mm diameter and 19mm thickness trapped a maximum magnetic field of 1.63T, which is more than 90% of the trapped magnetic flux density by FC magnetization. This result suggests that the pulse magnetizing method can replace the conventional field-cooled method and promote the practical use of HTS magnets for electromagnetic power applications.

  20. Protecting Superconducting HTS-Antennas by Meta-Material Cloaks

    DTIC Science & Technology

    2014-04-30

    AFRL-OSR-VA-TR-2014-0101 PROTECTING SUPERCONDUCTING HTS-ANTENNAS BY META-MATERIAL CLOAKS Horst Rogalla REGENTS OF THE UNIVERSITY OF COLORADO THE...Superconducting HTS-Antennas by Meta-Material Cloaks Contract/Grant #: FA9550-10-1-0413 Reporting Period: 1 Aug 2010 to 31 Jan 2014 Protecting...Superconducting HTS-Antennas by Meta-Material Cloaks Frank Trang1, Horst Rogalla1, 2, and Zoya Popović1 1Dept.of ECEE, University of Colorado, Boulder

  1. Efficient growth of HTS films with volatile elements

    DOEpatents

    Siegal, Michael P.; Overmyer, Donald L.; Dominguez, Frank

    1998-01-01

    A system for applying a volatile element-HTS layer, such as Tl-HTS, to a substrate in a multiple zone furnace, said method includes heating at higher temperature, in one zone of the furnace, a substrate and adjacent first source of Tl-HTS material, to sublimate Tl-oxide from the source to the substrate; and heating at lower temperature, in a separate zone of the furnace, a second source of Tl-oxide to replenish the first source of Tl-oxide from the second source.

  2. Efficient growth of HTS films with volatile elements

    DOEpatents

    Siegal, M.P.; Overmyer, D.L.; Dominguez, F.

    1998-12-22

    A system is disclosed for applying a volatile element-HTS layer, such as Tl-HTS, to a substrate in a multiple zone furnace, said method includes heating at higher temperature, in one zone of the furnace, a substrate and adjacent first source of Tl-HTS material, to sublimate Tl-oxide from the source to the substrate; and heating at lower temperature, in a separate zone of the furnace, a second source of Tl-oxide to replenish the first source of Tl-oxide from the second source. 3 figs.

  3. How to Tape an Ankle

    MedlinePlus

    ... Materials needed: 1½" athletic tape, Tuf-Skin/Quick Drying Adhesive, two pads to help prevent blistering (2" ... the start of the calf muscle. Use the spray adhesive to help secure the pre-wrap. Apply ...

  4. Canadian Contemporary Issues on Tape

    ERIC Educational Resources Information Center

    Shapter, Jean

    1974-01-01

    Four tapes with interviews with experts in the designated fields comprise the series: a) Canada's Foreign Relations, 1867-1919; b) Canada's Foreign Relations, 1919-1945; c) Canada and China, and d) Canadian Diplomacy and Foreign Policy. (JA)

  5. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  6. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  7. Tape Storage Optimization at BNL

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2011-12-01

    The BNL's RHIC and Atlas Computing Facility (RACF), is supporting the RHIC experiment as its Tier0 center and the Atlas/LHC as a Tier1 center. The RACF had to address the issue of efficient access to data stored to disk and tape storage. Randomly restoring files out of tapes destroys access performance to tape by causing too frequently, high latency and time consuming tape mount and dismount. BNL's mass storage system currently holds more than 16 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on a code from OakRidge National Lab, and then it was renamed to BNL Batch at 2005 after some major modifications and enhancements. The new BNL Batch, ERADAT, provides dynamic HPSS resource management, schedule jobs efficiently, enhanced visibility of real-time staging activities and advanced error handling, to maximize the tape staging performance. ERADAT is the interface between HPSS and other applications such as the DataCarousel, our home developed production system and dCache. Scalla/Xrootd MSS can also be interfaced with HPSS via DataCarousel. ERADAT has demonstrated great performance in BNL and other institute.

  8. What's up with duct tape

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.

    2005-03-01

    Recent research suggests that almost any tape can be made to work for a core-to-collar joint when perfectly applied. Given all the better choices available and all the problems that can and do occur in the field, we would not recommend that cloth-backed (natural) rubber-adhesive tapes be used, unless they can pass a suitable E2343 test. If visual degradation is an important factor, Oriented Polypropylene (OPP) and cloth-backed tapes should be avoided. While tapes that fail usually show visual degradation, the converse is not always true. We speculate, however, that visually degraded tapes are more likely to be susceptible to damage from vibration and other mechanical stresses. Conventional nylon straps are quite prone to fail at higher temperatures, but no systematic studies have yet been done across product classes. UL has proposed a new standard for straps, but the protocol for the current UL test does not, however, suggest that it would be a good indicator of durability. Products meeting the new UL standard for straps should be independently tested for the failure modes observed in the field and laboratory to determine if that test is a reasonable indicator of durability. Until a suitable test for strap durability exists, they recommend that only high temperature nylon or metal straps be used--especially in cases where tapes may be sensitive to mechanical stresses.

  9. HTS thin films: Passive microwave components and systems integration issues

    SciTech Connect

    Miranda, F.A.; Chorey, C.M.; Bhasin, K.B.

    1994-12-31

    The excellent microwave properties of the High-Temperature-Superconductors (HTS) have been amply demonstrated in the laboratory by techniques such as resonant cavity, power transmission and microstrip resonator measurements. The low loss and high Q passive structures made possible with HTS, present attractive options for applications in commercial, military and space-based systems. However, to readily insert HTS into these systems improvement is needed in such areas as repeatability in the deposition and processing of the HTS films, metal-contact formation, wire bonding, and overall film endurance to fabrication and assembly procedures. In this paper we present data compiled in our lab which illustrate many of the problems associated with these issues. Much of this data were obtained in the production of a space qualified hybrid receiver-downconverter module for the Naval Research Laboratory`s High Temperature Superconductivity Space Experiment II (HTSSE-II). Examples of variations observed in starting films and finished circuits will be presented. It is shown that under identical processing the properties of the HTS films can degrade to varying extents. Finally, we present data on ohmic contacts and factors affecting their adhesion to HTS films, strength of wire bonds made to such contacts, and aging effects.

  10. Rotor compound concept for designing an industrial HTS synchronous motor

    NASA Astrophysics Data System (ADS)

    Kashani, M.; Hosseina, M.; Sarrafan, K.; Darabi, A.

    2013-06-01

    Recently, producing power with smaller amount of losses become as a goal in our daily life. Today, large amount of energy waste in power networks all around the world. The main reason is “resistive electric equipments” of power networks. Since early 1980s, simultaneous with the development of high temperature superconductive (HTS) technology, superconductors gently attracted the mankind attentions. Using superconductive equipments instead of conventional resistive ones are result in salient electric loss reduction in power systems. Especially to reduce losses in power networks superconductive industrial rotating machines can potentially perform a significant role. In early recent century, first generation of HTS rotating machines was born. But unfortunately they have long way to penetrate the commercial markets yet. In HTS rotating machines the conventional copper made windings are replaced with the HTS superconductors. In this paper an industrial HTS synchronous motor with YBCO coated conductor field windings was designed. As a new approach, model was equipped with a compound rotor that includes both magnetic and non-magnetic materials. So, large amount of heavy iron made part was replaced by light non-magnetic material such as G-10 fiberglass. Furthermore, in this structure iron loss in rotor could be reduced to its lowest value. Also less weight and more air gap energy density were the additional advantages. Regarding zero electric loss production in field windings and less iron loss in rotor construction, this model potentially is more effective than the other iron made HTS motors.

  11. HTS thin films: Passive microwave components and systems integration issues

    NASA Technical Reports Server (NTRS)

    Miranda, F. A.; Chorey, C. M.; Bhasin, K. B.

    1995-01-01

    The excellent microwave properties of the High-Temperature-Superconductors (HTS) have been amply demonstrated in the laboratory by techniques such as resonant cavity, power transmission and microstrip resonator measurements. The low loss and high Q passive structures made possible with HTS, present attractive options for applications in commercial, military and spacebased systems. However, to readily insert HTS into these systems improvement is needed in such areas as repeatability in the deposition and processing of the HTS films, metal-contact formation, wire bonding, and overall film endurance to fabrication and assembly procedures. In this paper we present data compiled in our lab which illustrate many of the problems associated with these issues. Much of this data were obtained in the production of a space qualified hybrid receiver-downconverter module for the Naval Research Laboratory's High Temperature Superconductivity Space Experiment 2 (HTSSE-2). Examples of variations observed in starting films and finished circuits will be presented. It is shown that under identical processing the properties of the HTS films can degrade to varying extents. Finally, we present data on ohmic contacts and factors affecting their adhesion to HTS films, strength of wire bonds made to such contacts, and aging effects.

  12. Quick-release medical tape.

    PubMed

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M

    2012-11-13

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive-skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes.

  13. HTS electrical machines with YBCO bulk and Ag-BSCCO plate-shape HTS elements: recent results and future development

    NASA Astrophysics Data System (ADS)

    Kovalev, L. K.; Ilushin, K. V.; Penkin, V. T.; Kovalev, K. L.; Koneev, S. M.-A.; Modestov, K. A.; Larionoff, S. A.; Gawalek, W.; Oswald, B.

    2001-05-01

    Novel types of electric HTS motors with the rotor containing bulk YBCO elements are presented. Different schematics of hysteresis, reluctance “trapped field” and composed HTS motors are discussed. The two-dimensional mathematical models describing the processes in such types of HTS machines were developed on the basis of the theoretical analysis of the electrodynamic and hysteresis processes in the multi-domain and single-domain YBCO ceramic samples. The test results of the series of these HTS motors with output power 1-20 kW and current frequency 50 and 400 Hz are given. These results show that in the media of liquid nitrogen the specific output power per one weight unit is four to five times better then for conventional electric machines. The design of a new high power HTS motor operating in the liquid nitrogen with output power 200 kW (and more) is discussed. Future applications of new types of HTS motors for airspace and on-land industry and transport systems are discussed.

  14. Novel digital optical tape recorder

    NASA Astrophysics Data System (ADS)

    Oakley, William S.

    1996-01-01

    A novel very high performance digital optical tape recorder is described. Linear tape motion at 4.2 meters per second and simultaneous writing of about 80 parallel bit tracks with a data density of three bits per micron per track enables a data rate of 1,000 Megabits per second, sufficient for a data rate of 100 megabytes per second with error correction. One micron track to track spacing gives a data capacity of one Terabyte (1,000 GB) in a single '3480' style tape cartridge shell. A single beam from a frequency doubled, laser diode pumped, solid state (2X- LDP-SS) laser is split into a multiplicity of like beams, each of which is then independently modulated at 12.5 MHz for recording.

  15. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  16. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  17. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  18. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  19. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  20. Cryostat Design for an HTS Transformer

    NASA Astrophysics Data System (ADS)

    Trollier, T.; Ravex, A.; Poncet, J. M.; Tixador, P.; Donnier-Valentin, G.; Maher, E.

    2004-06-01

    A single-phase 41-kVA 2050V / 410V single-phase transformer demonstrator has been designed and manufactured as an integrated complete device with cooling system. A cold magnetic circuit design has been chosen for overall structural simplicity in a single metallic cryostat. The superconducting coils are solenoids. The primary winding uses a PIT-Bi-2223 tape. A secondary is wound with two lengths of YBCO coated conductors. The cooler used is a single-stage, high cooling power, coaxial GM-type pulse tube offering a cooling capacity of 80 W at 60 K or 100 W at 80 K using a 5 kW compressor. The original design of the cryostat architecture is detailed. The thermal and electrical performance tests (no-load and short-circuit tests) with an half primary and a reduced secondary (75 V - 50 A @ 77 K) are also presented.

  1. A Study of Audio Tape: Part II

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    To evaluate reel audio tape, tests were performed to identify: signal-to-noise ratio, total harmonic distortion, dynamic response, frequency response, biased and virgin tape noise, dropout susceptibility and oxide coating uniformity. (SCC)

  2. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  3. Modelling ac ripple currents in HTS coated conductors

    NASA Astrophysics Data System (ADS)

    Xu, Zhihan; Grilli, Francesco

    2015-10-01

    Dc transmission using high temperature superconducting (HTS) coated conductors (CCs) offers a promising solution to the globally growing demand for effective, reliable and economic transmission of green energy up to the gigawatt level over very long distances. The credible estimation of the losses and thereby the heat dissipation involved, where ac ripples (introduced in rectification/ac-dc conversion) are viewed as a potential source of notable contribution, is highly essential for the rational design of practical HTS dc transmission cables and corresponding cryogenic systems to fulfil this demand. Here we report a targeted modelling study into the ac losses in a HTS CC subject to dc and ac ripple currents simultaneously, by solving Maxwell’s equations using the finite element method (FEM) in the commercial software package COMSOL. It is observed that the instantaneous loss exhibits only one peak per cycle in the HTS CC subject to sinusoidal ripples, given that the amplitude of the ac ripples is smaller than approximately 20% of that of the dc current. This is a distinct contrast to the usual observation of two peaks per cycle in a HTS CC subject to ac currents only. The unique mechanism is also revealed, which is directly associated with the finding that, around any local minima of the applied ac ripples, the critical state of -J c is never reached at the edges of the HTS CC, as it should be according to the Bean model. When running further into the longer term, it is discovered that the ac ripple loss of the HTS CC in full-wave rectification decays monotonically, at a speed which is found to be insensitive to the frequency of the applied ripples within our targeted situations, to a relatively low level of approximately 1.38 × 10-4 W m-1 in around 1.7 s. Comparison between this level and other typical loss contributions in a HTS dc cable implies that ac ripple currents in HTS CCs should only be considered as a minor source of dissipation in superconducting dc

  4. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    NASA Astrophysics Data System (ADS)

    Gorospe, A.; Nisay, A.; Dizon, J. R.; Shin, H. S.

    2013-11-01

    The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The Ic degradation behaviour under transverse load was related to the location where delamination occurred in the sample.

  5. Parametric Study of HTS Coil Quench Protection Strategies

    NASA Astrophysics Data System (ADS)

    Seibert, Joseph; Zarnstorff, Michael; Zhai, Yuhu

    2016-10-01

    Next generation fusion devices require high magnetic fields to adequately contain burning plasmas. Use of high temperature superconducting (HTS) coils to generate these magnetic fields would lower energy cost of operation as well as increase stability of the superconducting state compared to low temperature superconducting coils. However, use of HTS coils requires developing quench protection strategies to prevent damage to the coils. One technique involves the utilization of copper discs and other conductors mutually coupled to the HTS coil to quickly extract the current from the coil. Another technique allows conduction between HTS turns to reduce the current in the coil during quench. This project describes a parametric study of the HTS coil and resistive-conductor setup in order to determine limiting cases of the geometry in an attempt to optimize current extraction and coil protection during quench scenarios. This work was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Science Undergraduate Laboratory Internship (SULI) program.

  6. A Study of Audio Tape

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    This is part I of a report on a study comparing reel and cassette tapes for signal-to-noise ration, total harmonic distortion, dynamic response, frequency response, bias and virgin noise and oxide coating uniformity. Test equipment and procedures are described and results are discussed. Charts detail research findings. (CHK)

  7. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  8. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  9. Monolithic HTS microwave phase shifter and other devices

    SciTech Connect

    Jackson, C.M.; Kobayashi, J.H.; Guillory, E.B.; Pettiette-Hall, C.; Burch, J.F. )

    1992-08-01

    We describe a monolithic high-temperature superconductor (HTS) phase shifter based on the distributed Josephson inductance (DJI) design integrated monolithically into a 10-GHz microstrip line. This microwave circuit incorporates >1000 HTS rf SQUIDS. Recent data demonstrate the performance of this broadband HTS circuit. We observed phase shifts greater than 150[degrees] in resonant structures, and 20[degrees] in broadband circuits. The nonlinear inductance of the superconducting transmission line can be used for other novel applications, including parametric amplification. A comparison of the DJI circuit to a series array of Josephson elements (used for pulse sharpening) will contrast these two new and exciting nonlinear transmission line circuits. 19 refs., 4 figs., 2 tabs.

  10. Loss analysis of a 1 MW class HTS synchronous motor

    NASA Astrophysics Data System (ADS)

    Baik, S. K.; Kwon, Y. K.; Kim, H. M.; Lee, J. D.; Kim, Y. C.; Park, H. J.; Kwon, W. S.; Park, G. S.

    2009-03-01

    The HTS (High-Temperature Superconducting) synchronous motor has advantages over the conventional synchronous motor such as smaller size and higher efficiency. Higher efficiency is due to smaller loss than the conventional motor, so it is important to do loss analysis in order to develop a machine with higher efficiency. This paper deals with machine losses those are dissipated in each part of a HTS synchronous motor. These losses are analyzed theoretically and compared with loss data obtained from experimental results of a 1 MW class HTS synchronous motor. Each machine loss is measured based on IEEE 115 standard and the results are analyzed and considered based on the manufacturing of the test machine.

  11. HTS power lead testing at the Fermilab magnet test facility

    SciTech Connect

    Rabehl, R.; Carcagno, R.; Feher, S.; Huang, Y.; Orris, D.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.; /Fermilab

    2005-08-01

    The Fermilab Magnet Test Facility has tested high-temperature superconductor (HTS) power leads for cryogenic feed boxes to be placed at the Large Hadron Collider (LHC) interaction regions and at the new BTeV C0 interaction region of the Fermilab Tevatron. A new test facility was designed and operated, successfully testing 20 pairs of HTS power leads for the LHC and 2 pairs of HTS power leads for the BTeV experiment. This paper describes the design and operation of the cryogenics, process controls, data acquisition, and quench management systems. Results from the facility commissioning are included, as is the performance of a new insulation method to prevent frost accumulation on the warm ends of the power leads.

  12. Development of Magnet Technologies for HTS Insert Coils

    NASA Astrophysics Data System (ADS)

    Wesche, Rainer; Uglietti, Davide; Bruzzone, Pierluigi; March, Stephen; Marinucci, Claudio; Stepanov, Boris; Glowa, Natalia

    An existing Nb3Sn laboratory magnet generating a magnetic field of 12 T is intended to be upgraded to 16 T by means of the use of a high temperature superconductor (HTS) insert coil. An outline design of the HTS insert coil is presented. In the design, the aspects of the maximum achievable operation current, the required copper cross-section to ensure a hot spot temperature below 200 K and the resulting forces and stresses have been considered. The length of the insert coil has been selected in such a way that the field uniformity will be better than 1% within a sphere of 3 cm diameter. The protection of the whole magnet system (LTS & HTS insert) is briefly described.

  13. A silver-bearing, High-Temperature, Superconducting (HTS) paint

    NASA Astrophysics Data System (ADS)

    Ferrando, William A.

    1990-02-01

    A substantial set of device applications awaits development of a workable, durable, high-temperature superconducting (HTS) paint. Such a paint should be truly superconducting with its critical temperature T sub c greater than 77K. For most of these applications, a high critical current (J sub c) is not required, although probably desirable. A process is described which can be used to produce silver-bearing HTS paint coatings on many engineering materials. Preliminary tests have shown good adherence to several ceramics and the ability to meet the superconducting criteria. Moreover, the coatings withstand multiple thermal cycling and stability under laboratory ambient storage conditions for periods of at least several months.

  14. The Evaluation of Student Attitudes toward MC2G

    ERIC Educational Resources Information Center

    Basol-Gocmen, Gulsah; Kanyongo, Gibbs Y.; Blankson, Lydia

    2002-01-01

    The purpose of this paper is to evaluate the use of MC2G program to teach certain topics in statistics education. MC2G is a program written in Pascal Delphi by Gordon Brooks of Ohio University based on Monte Carlo studies. MC2G provides students opportunity to practice important topics in an introductory statistics course, such as power, Type I…

  15. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  16. Test Results for a 25 Meter Prototype Fault Current Limiting Hts Cable for Project Hydra

    NASA Astrophysics Data System (ADS)

    Rey, C. M.; Duckworth, R. C.; Demko, J. A.; Ellis, A.; James, D. R.; Gouge, M. J.; Tuncer, E.

    2010-04-01

    The Oak Ridge National Laboratory (ORNL) has tested a 25-m long prototype High Temperature Superconducting (HTS) cable with inherent Fault-Current Limiting (FCL) capability at its HTS cable test facility. The HTS-FCL cable and terminations were designed and fabricated by Ultera, which is a joint venture between Southwire and nkt cables. System integration and HTS wire were provided by American Superconductor Corporation who was the overall team leader of the project. The ultimate goal of the 25-m HTS-FCL cable test program was to verify the design and ensure the operational integrity for the eventual installation of a ˜200-m fully functional HTS-FCL cable in the Consolidated Edison electric grid located in downtown New York City. The 25-m HTS-FCL cable consisted of a three-phase (3-Φ) HTS Triax™ design with a cold dielectric between the phases. The HTS-FCL cable had an operational voltage of 13.8 kV phase-to-phase (7967 V phase-to-ground) and an operating current of 4000 Arms per phase, which is the highest operating current to date of any HTS cable. The 25-m HTS-FCL cable was subjected to a series of cryogenic and electrical tests. Test results from the 25-m HTS-FCL cable are presented and discussed.

  17. Designing HTS Roebel cables for low-field applications with open-source code

    NASA Astrophysics Data System (ADS)

    Grilli, Francesco; Zermeño, Victor M. R.; Kario, Anna

    2016-11-01

    In HTS Roebel cables for low-field applications the tightly packed strands produce a substantial self-field, which can be comparable to the background field the cable operates in. As a result, the self-field critical current (Ic) of a cable is lower than the value obtained by multiplying the self-field Ic of the strands by the number of strands. In addition, the in-field reduction of the superconducting material plays an important role for a cable's Ic. Numerical models can accurately calculate the magnetic field distribution inside a cable and estimate its Ic. In this contribution we employ a recently developed open-source model to estimate the Ic of Roebel cables. In particular, we investigate the influence of the spacing between the superconducting layers, of the Jc(B, θ) dependence, and of the presence of an external magnetic field. For the present analysis, we consider tapes from two manufactures, whose properties were characterized in our group.

  18. High density tape casting system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1989-01-01

    A system is provided for casting thin sheets (or tapes) of particles bound together, that are used for oxygen membranes and other applications, which enables the particles to be cast at a high packing density in a tape of uniform thickness. A slurry contains the particles, a binder, and a solvent, and is cast against the inside walls of a rotating chamber. Prior to spraying the slurry against the chamber walls, a solvent is applied to a container. The solvent evaporates to saturate the chamber with solvent vapor. Only then is the slurry cast. As a result, the slurry remains fluid long enough to spread evenly over the casting surface formed by the chamber, and for the slurry particles to become densely packed. Only then is the chamber vented to remove solvent, so the slurry can dry. The major novel feature is applying solvent vapor to a rotating chamber before casting slurry against the chamber walls.

  19. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  20. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  1. Experimental studies of helical solenoid model based on YBCO tape-bridge joints

    SciTech Connect

    Yu, M.; Lombardo, V.; Turrioni, D.; Zlobin, A.V.; Flangan, G.; Lopes, M.L.; Johnson, R.P.; /Fermilab

    2011-06-01

    Helical solenoids that provide solenoid, helical dipole and helical gradient field components are designed for a helical cooling channel (HCC) proposed for cooling of muon beams in a muon collider. The high temperature superconductor (HTS), 12 mm wide and 0.1 mm thick YBCO tape, is used as the conductor for the highest-field section of HCC due to certain advantages, such as its electrical and mechanical properties. To study and address the design, and technological and performance issues related to magnets based on YBCO tapes, a short helical solenoid model based on double-pancake coils was designed, fabricated and tested at Fermilab. Splicing joints were made with Sn-Pb solder as the power leads and the connection between coils, which is the most critical element in the magnet that can limit the performance significantly. This paper summarizes the test results of YBCO tape and double-pancake coils in liquid nitrogen and liquid helium, and then focuses on the study of YBCO splices, including the soldering temperatures and pressures, and splice bending test.

  2. High-temperature superconducting magnets and coils from silver- sheathed Bi-2223 tapes

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.

    1993-10-01

    Long lengths (30 to 100 m) of silver-sheathed Bi-2223 tapes with high current densities were fabricated by the conventional powder-in-tube technique and used to make compact and robust coils by the wind-and-react approach. The tapes were insulated co-wound in parallel, and heat treated to produce a fused conductor of larger cross section in the form of pancake coils. The coils were stacked in series to make test magnets. The coils and test magnets were characterized at liquid nitrogen (77 K) and liquid helium (4.2 K) temperatures. The highest field generated by the test magnets was measured to be 0.36 T at liquid nitrogen and 2.6 T at liquid helium temperatures. Progress in the prototype manufacturing of long lengths of HTS tape conductor is also discussed. 30 to 100 m lengths are now being made and 70 m lengths were measured to carry 23 Amps (J{sub c} {approximately} 15,000 A/cm{sup 2}) when immersed in liquid nitrogen.

  3. HTS DC Transmission Line for Megalopolis Grid Development

    NASA Astrophysics Data System (ADS)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  4. Materials processing and machine applications of bulk HTS

    NASA Astrophysics Data System (ADS)

    Miki, M.; Felder, B.; Tsuzuki, K.; Xu, Y.; Deng, Z.; Izumi, M.; Hayakawa, H.; Morita, M.; Teshima, H.

    2010-12-01

    We report a refrigeration system for rotating machines associated with the enhancement of the trapped magnetic flux of bulk high-temperature superconductor (HTS) field poles. A novel cryogenic system was designed and fabricated. It is composed of a low-loss rotary joint connecting the rotor and a closed-cycle thermosiphon under a GM cryocooler using a refrigerant. Condensed neon gas was adopted as a suitable cryogen for the operation of HTS rotating machines with field poles composed of RE-Ba-Cu-O family materials, where RE is a rare-earth metal. Regarding the materials processing of the bulks HTS, thanks to the addition of magnetic particles to GdBa2Cu3O7 - d (Gd123) bulk superconductors an increase of more than 20% in the trapped magnetic flux density was achieved at liquid nitrogen temperature. Field-pole Gd123 bulks up to 46 mm in diameter were synthesized with the addition of Fe-B alloy magnetic particles and assembled into the synchronous machine rotor to be tested. Successful cooling of the magnetized rotor field poles down to 35 K and low-output-power rotating operation was achieved up to 720 rpm in the test machine with eight field-pole bulks. The present results show a substantial basis for making a prototype system of rotating machinery of applied HTS bulks.

  5. Large-scale HTS bulks for magnetic application

    NASA Astrophysics Data System (ADS)

    Werfel, Frank N.; Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter

    2013-01-01

    ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN2 and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500-3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN2 allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved.

  6. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  7. Test Results For a 25-m Prototype Fault Current Limiting HTS Cable for Project Hydra

    SciTech Connect

    Rey, Christopher M; Duckworth, Robert C; Demko, Jonathan A; Ellis, Alvin R; Gouge, Michael J; James, David Randy; Tuncer, Enis

    2010-01-01

    The Oak Ridge National Laboratory (ORNL) has tested a 25-m long prototype High Temperature Superconducting (HTS) cable with inherent Fault-Current Limiting (FCL) capability at its recently upgraded HTS cable test facility in Oak Ridge, TN. The HTS-FCL cable and terminations were designed and fabricated by Ultera, which is a joint venture of Southwire and nkt cables with FCL features and HTS wire provided by American Superconductor Corporation. The overall project is sponsored by the U.S. Department of Homeland Security. The ultimate goal of the 25-m HTS-FCL cable test program was to verify the design and ensure the operational integrity for the eventual installation of a ~ 200-m fully functional HTS-FCL cable in the Consolidated Edison electric grid located in downtown New York City. The 25-m HTS-FCL cable consisted of a three-phase (3- ) Triax design with a cold dielectric between the phases. The HTS-FCL cable had an operational voltage of 13.8 kV phase-to-phase and an operating current of 4000 Arms per phase, which is the highest operating current to date of any HTS cable. The 25-m HTS-FCL cable was subjected to a series of cryogenic and electrical tests. Test results from the 25-m HTS-FCL cable are presented and discussed.

  8. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  9. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    SciTech Connect

    Selvamanickam, V; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Yao, Y; Xiong, X; Lei, C; Soloveichik, S; Galstyan, E; Majkic, G

    2013-01-21

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12 mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  10. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Chen, Y.; Shi, T.; Liu, Y.; Khatri, N. D.; Liu, J.; Yao, Y.; Xiong, X.; Lei, C.; Soloveichik, S.; Galstyan, E.; Majkic, G.

    2013-03-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm-2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m-3. The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  11. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  12. HTS step-edge Josephson junction terahertz harmonic mixer

    NASA Astrophysics Data System (ADS)

    Du, Jia; Weily, Andrew R.; Gao, Xiang; Zhang, Ting; Foley, Cathy P.; Guo, Yingjie Jay

    2017-02-01

    A high-temperature superconducting (HTS) terahertz (THz) frequency down-converter or mixer based on a thin-film ring-slot antenna coupled YBa2Cu3O7-x (YBCO)/MgO step-edge Josephson junction is reported. The frequency down-conversion was achieved using higher order harmonics of an applied lower frequency (19-40 GHz) local oscillator signal in the Josephson junction mixing with a THz signal of over 600 GHz, producing a 1-3 GHz intermediate frequency signal. Up to 31st order of harmonic mixing was obtained and the mixer operated stably at temperatures up to 77 K. The design details of the antenna, HTS Josephson junction mixer, the matching and isolation circuits, and the DC and RF performance evaluation are described in this paper.

  13. High voltage insulation of bushing for HTS power equipment

    NASA Astrophysics Data System (ADS)

    Kim, Woo-Jin; Choi, Jae-Hyeong; Kim, Sang-Hyun

    2012-12-01

    For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. Liquid nitrogen (LN2) is an attractive dielectric liquid. Also, the polymer insulating materials are expected to be used as solid materials such as glass fiber reinforced plastic (GFRP), polytetra-fluoroethylene (PTFE, Teflon), Silicon (Si) rubber, aromatic polyamide (Nomex), EPDM/Silicon alloy compound (EPDM/Si). In this paper, the surface flashover characteristics of various insulating materials in LN2 are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The use of GFRP and Teflon as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in LN2 and operation of superconducting equipments.

  14. Fault current limiters and fault current switches based on wide HTS tapes: low cryo-consumption, new applications

    NASA Astrophysics Data System (ADS)

    Usoskin, A.; Rao, V. V.; Dietrich, R.; Rutt, A.; Schlenga, K.

    2017-02-01

    When the fault current limiter yields influential response within 0.1 milliseconds, it demonstrates ultra-fast switching behaviour that is significantly faster than the response of the best mechanical and superconducting devices. Such ultra-fast response was demonstrated in recently developed superconducting fault current limiters (SFCLs) of inductive type. Secondary coil of the limiter was constructed from a set of closed rings made out of 40 mm wide YBCO coated conductor that was capable of nucleating wide normal zone in the beginning of quench process. Due to reduction of heat capacity and avoiding internal and external shunts, the ultra-fast switching behaviour with characteristic times of 50-100 microseconds was achieved. The ultra-fast performance results in a suppression of energy absorbed in the device during transient/quenching process as well as in low power dissipation after quenching of the superconducting element. This allows to maintain a very low power dissipation in the limiting modus duration which may be extended therefore to hours. Drastic reduction (by a factor of 10-50 in comparison with conventional types of SFCLs) of cryoconsumption was experimentally demonstrated at both normal operating modus and limiting (quenched) modus. Different ways for implementation of ultra-fast switching performance in fault current limiters are considered and discussed.

  15. Application of HTS technology to cardiac dysrhythmia detection

    SciTech Connect

    Sobel, A.L.; Avrin, W.F.

    1994-12-01

    This paper discusses the conceptual design considerations and challenges for development of a contactless, mobile, single channel biomagnetic sensor system based on High-Temperature Superconductor (HTS) Superconducting Quantum Interference Devices (SQUIDs) and employing the Three-SQUID Gradiometer (TSG) concept. Operating in magnetically unshielded environments, as are encountered in many medical scenarios, this instrument class would monitor cardiac electrical activity with minimal patient preparation and intrusiveness, and would notionally be coupled with a clinically adaptive human-system interface (HSI).

  16. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    NASA Astrophysics Data System (ADS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-11-01

    A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous Ic measurement, we found that our new multi-filamentary tape could provide almost equal Ic compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  17. Bandaging and taping considerations for the dancer.

    PubMed

    Ewalt, Katherine L

    2010-01-01

    Although widely disputed, bandaging and taping techniques are common practice in sports medicine. This article reviews literature related to the efficacy of bandaging and taping procedures and their role in sport and dance medicine. It further examines dance-specific application principles, and outlines selected techniques for treatment of common dance-related pathologies.

  18. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are... nystagmus (abnormal and irregular eye movements) and to test for blindness. (b) Classification. Class...

  19. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are... nystagmus (abnormal and irregular eye movements) and to test for blindness. (b) Classification. Class...

  20. Electrical Model of Balanced AC HTS Power Cable

    NASA Astrophysics Data System (ADS)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Willén, D.; Melnik, I.; Geschiere, A.

    The future electricity grid will be more sustainable and it will have more power transmission and distribution capability with more electrical power added from decentralized sources on distribution level and from wind parks and other large sources on transmission level. More interconnections and more underground transmission and distribution will be put up. Use of high temperature superconducting (HTS) power cables provides solutions to many of the future grid problems caused by these trends. In this paper we present an electrical model of a balanced 6 km-long three phase triaxial HTS power cable for the Dutch project being developed by a consortium of Alliander, Ultera™ and TUD. The cable currents in all three phases are balanced by selecting proper twist pitches and insulation thickness. The paper focuses on determining inductances, capacitances and AC losses of the balanced cable. Using the developed model, we also determine the voltage drop as function of the cable length, the neutral current and the effect of the imbalanced capacitances on the current distribution of the Dutch distribution cable. The model is validated and it can be used for accurate simulation of the electrical behaviour of triaxial HTS cables in electrical grids.

  1. Enhanced HTS hit selection via a local hit rate analysis.

    PubMed

    Posner, Bruce A; Xi, Hualin; Mills, James E J

    2009-10-01

    The postprocessing of high-throughput screening (HTS) results is complicated by the occurrence of false positives (inactive compounds misidentified as active by the primary screen) and false negatives (active compounds misidentified as inactive by the primary screen). An activity cutoff is frequently used to select "active" compounds from HTS data; however, this approach is insensitive to both false positives and false negatives. An alternative method that can minimize the occurrence of these artifacts will increase the efficiency of hit selection and therefore lead discovery. In this work, rather than merely using the activity of a given compound, we look at the presence and absence of activity among all compounds in its "chemical space neighborhood" to give a degree of confidence in its activity. We demonstrate that this local hit rate (LHR) analysis method outperforms hit selection based on ranking by primary screen activity values across ten diverse high throughput screens, spanning both cell-based and biochemical assay formats of varying biology and robustness. On average, the local hit rate analysis method was approximately 2.3-fold and approximately 1.3-fold more effective in identifying active compounds and active chemical series, respectively, than selection based on primary activity alone. Moreover, when applied to finding false negatives, this method was 2.3-fold better than ranking by primary activity alone. In most cases, novel hit series were identified that would have otherwise been missed. Additional uses of and observations regarding this HTS analysis approach are also discussed.

  2. The Effect of the Kinesio Taping and Spiral Taping on Menstrual Pain and Premenstrual Syndrome

    PubMed Central

    Lim, Chaegil; Park, Yongnam; Bae, Youngsook

    2013-01-01

    [Purpose] The purpose of this study was to compare the effects of Kinesio taping and spiral taping on menstrual pain and premenstrual syndrome, to investigate the efficacy of the two types of taping as methods for alleviating menstrual pain and premenstrual syndrome. [Subjects and Methods] The subjects of this study were 34 unmarried women. The subjects were randomly divided into a Kinesio taping group, a spiral taping group and a control group. Subjects with a regular menstrual cycle underwent taping a total of six times; twice a week for about three weeks, starting from 14 days before menstruation and continuing until its end. Degrees of menstrual pain and premenstrual syndrome were measured before the application of taping. [Results] The results revealed that Kinesio taping had significant effects on menstrual pain, while spiral taping was effective at alleviating both menstrual pain and premenstrual syndrome. [Conclusion] Both taping methods before menstruation brought significant relief to menstrual pain, which suggests that spiral taping is an effective method of alleviating premenstrual symptoms. PMID:24259847

  3. Transfer of adhesive tape between calender rolls

    NASA Astrophysics Data System (ADS)

    Johnson, K. L.; Kauzlarich, J. J.

    2004-03-01

    In the calendering process a tape or sheet of deformable material passes through the nip between hard cylindrical rollers. Usually the rolls are driven at the same peripheral speed, but small differences in speed, often referred to as 'creep', can occur if one of the rolls is externally driven and the other is driven by the friction in the contact. In these circumstances it has been observed that a tape that enters the nip adhering to the driven (slower) surface may transfer at exit to the driving (faster) surface but not the other way round. The mechanics of this transfer process is examined theoretically and experimentally in this paper for the case of double sided adhesive tape. It is argued that on emerging from the nip the tape will separate from the surface at which the shear strain in the adhesive is greater and that for transfer to occur the contact load must be sufficient to cause plastic extension of the tape.

  4. Mechanical stabilization of BSCCO-2223 superconducting tapes

    SciTech Connect

    King, C.G.; Grey, D.A.; Mantone, A.

    1996-12-31

    A system to provide mechanical stabilization to high temperature BSCCO-2223 superconducting tape by laminating 0.081 mm thick, spring hard, copper foil to both sides with lead-tin eutectic solder has been successfully optimized. This system has been applied as a method to create a strong, windable composite from pure silver BSCCO tapes with a minimum of critical current (I{sub c}) degradation. The {open_quotes}as received{close_quotes} conductor is evaluated for physical consistency of width and thickness over the 3000 meters that were later strengthened, insulated and wound into a demonstration coil. Electrical degradation in the strengthened tape as a result of lamination was found to average 24 percent with a range from 4 to 51 percent. This was less than the degradation that would have occurred in an unstrengthened tape during subsequent insulation and coil winding processes. Additional work was performed to evaluate the mechanical properties of the strengthened tapes. The copper can double the ultimate tensile strength of the pure silver tapes. Additionally, pure silver and dispersion strengthened silver matrix tapes are laminated with 0.025 mm thick copper and 304 stainless steel foil to investigate minimization of the cross sectional area of the strengthening component. The stainless steel can increase the UTS of the pure silver tapes sixfold. Metallography is used to examine the laminate and the conductor. Mechanical properties and critical currents of these tapes are also reported both before and after strengthening. The I{sub c} is also measured as a function of strain on the laminated tapes.

  5. Demonstration project cuts red tape

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    Results from a demonstration project aimed at cutting red tape in federal grants for basic research at universities are "very encouraging" so far, according to Don I. Phillips, executive director of the Government-University-Industry Research Roundtable. The roundtable is coordinating the experimental effort, with the participation of five major federal agencies as well as the Florida state university system and the University of Miami (a private institution in Coral Gables, Fla.).Under the project, special conditions apply to grants from the participating agencies to individual researchers at the participating universities: Investigators do not have to ask the agency's permission for changes in budget allocations, purchases of permanent equipment, or foreign travel. Grant money can be spent up to a year after the grant ends without a special request. Under this plan, researchers, with agency approval, can also ask to have their entire research program covered as a single administrative entity, rather than as several individual projects.

  6. The insulation design for transmission class HTS transformer with continuous disk winding

    NASA Astrophysics Data System (ADS)

    Cheon, H. G.; Kwag, D. S.; Choi, J. H.; Kim, S. H.

    2007-10-01

    In the response to the demands for electrical energy, much effort aimed to develop and commercialize HTS power equipments have been made around the world. Among them HTS transformer is one of very promising one. In Korea, companies and universities are developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects. The composite continuous disk winding of transmission class HTS transformer is concentrically arranged H1-L-H2 from center. For the development of transmission HTS transformer with continuous disk winding, the cryogenic insulation technology should be established. We have been analyzed insulation composition and investigated electrical characteristics such as the breakdown of LN2, barrier, kapton films, flashover on FRP in LN2. We are going to compare with measured each value and apply the value to most suitable insulating design of the HTS transformer.

  7. Development of high sensitive magnetic contaminant detection system using an HTS-rf-SQUID covered with HTS thin films

    NASA Astrophysics Data System (ADS)

    Hatsukade, Y.; Kurosawa, R.; Uchida, Y.; Tanaka, S.

    2012-03-01

    For high sensitive detection of magnetic contaminant in electrode of lithium-ion battery, high-temperature superconductor (HTS) radio-frequency (rf) superconducting quantum interference devices (SQUIDs) based on a bicrystal SrTiO3 (STO) substrate was designed, and fabricated employing YBa2Cu3O7-x thin films of about 200 nm in thickness. To improve characteristics such as effective area and 1/f noise profile of the SQUID, HTS thin films on normal STO substrates were overlapped on a wide superconducting weak link and/or a slit of the SQUID in flip-chip configuration. The noise profiles of the SQUID covered with the films on the respective positions were well improved compared to that of the bare SQUID. A magnetic contaminant detection system was developed employing the HTS-rf-SQUID covered with the films on both the positions. Using this system, a tungsten ball of 30 μm in diameter was successfully detected with a signal to noise ratio of about 14.

  8. Present status and future trends of R&D for HTS rotational machines in Japan

    NASA Astrophysics Data System (ADS)

    Tsukamoto, Osami

    2014-09-01

    Various HTS rotating machines, from multiple MW class to several 10 kW class, are being developed in Japan. R&D statuses of those machines are reviewed. Design studies of various types of HTS wind power generators are also conducted in Japan and their merits and demerits are discussed. Based on the present R&D statuses, future technical trends of HTS machines are discussed.

  9. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  10. Towards G2G: Systems of Technology Database Systems

    NASA Technical Reports Server (NTRS)

    Maluf, David A.; Bell, David

    2005-01-01

    We present an approach and methodology for developing Government-to-Government (G2G) Systems of Technology Database Systems. G2G will deliver technologies for distributed and remote integration of technology data for internal use in analysis and planning as well as for external communications. G2G enables NASA managers, engineers, operational teams and information systems to "compose" technology roadmaps and plans by selecting, combining, extending, specializing and modifying components of technology database systems. G2G will interoperate information and knowledge that is distributed across organizational entities involved that is ideal for NASA future Exploration Enterprise. Key contributions of the G2G system will include the creation of an integrated approach to sustain effective management of technology investments that supports the ability of various technology database systems to be independently managed. The integration technology will comply with emerging open standards. Applications can thus be customized for local needs while enabling an integrated management of technology approach that serves the global needs of NASA. The G2G capabilities will use NASA s breakthrough in database "composition" and integration technology, will use and advance emerging open standards, and will use commercial information technologies to enable effective System of Technology Database systems.

  11. Hysteresis and reluctance electric machines with bulk HTS elements. Recent results and future development

    NASA Astrophysics Data System (ADS)

    Kovalev, L. K.; Ilushin, K. V.; Penkin, V. T.; Kovalev, K. L.; M-A Koneev, S.; Poltavets, V. N.; Larionoff, A. E.; Modestov, K. A.; Larionoff, S. A.; Gawalek, W.; Habisreuther, T.; Oswald, B.; Best, K.-J.; Strasser, T.

    2000-05-01

    Two new types of HTS electric machine are considered. The first type is hysteresis motors and generators with cylindrical and disc rotors containing bulk HTS elements. The second type is reluctance motors with compound HTS-ferromagnetic rotors. The compound HTS-ferromagnetic rotors, consisting of joined alternating bulk HTS (YBCO) and ferromagnetic (iron) plates, provide a new active material for electromechanical purposes. Such rotors have anisotropic properties (ferromagnetic in one direction and diamagnetic in the perpendicular one). Theoretical and experimental results for HTS hysteresis and reluctance motors are presented. A series of hysteresis HTS motors with output power rating from 1 kW (at 50 Hz) up to 4 kW (at 400 Hz) and a series of reluctance HTS motors with output power 2-18.5 kW (at 50 Hz) were constructed and successfully tested. It was shown that HTS reluctance motors could reach two to five times better overall dimensions and specific power than conventional asynchronous motors of the same size and will have higher values of power factor (cos ϕ≥0.7 to 0.8).

  12. Ferromagnetic resonance of particulate magnetic recording tapes

    NASA Astrophysics Data System (ADS)

    Netzelmann, U.

    1990-08-01

    The room-temperature ferromagnetic resonance (FMR) spectra of γ-Fe2O3, CrO2, and barium ferrite particulate magnetic recording tapes have been measured at microwave frequencies of 9.35 and 35 GHz for various orientations of the static and high-frequency magnetic fields with respect to the tape. For CrO2 tapes, the influence of the width of the angular distribution of the particle orientations on the FMR spectra has been studied from the nearly isotropic case up to the highly oriented case. Hysteretic behavior for a CrO2 tape as well as the effect of tape calendering for a γ-Fe2O3 tape has been observed by FMR. Experimental results are found to be in reasonable agreement with results of theoretical calculations based on a model of an ellipsoidal single-domain particle with both shape and magnetocrystalline anisotropy. Magnetostatic interaction inside the magnetic film has been introduced by expressing the total magnetostatic energy as a combination of a part dependent on particle shape and a part dependent on the shape of the tape. As a result of a comparison of experimental data with calculated data from the model, the magnetocrystalline easy axis of the CrO2 particles is found to be parallel with the particle axis.

  13. From Ions to Wires to the Grid: The Transformational Science of LANL Research in High-Tc Superconducting Tapes and Electric Power Applications

    ScienceCinema

    Marken, Ken [Superconductivity Technology Center, Los Alamos, New Mexico, United States

    2016-07-12

    The Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) has been tasked to lead national efforts to modernize the electric grid, enhance security and reliability of the energy infrastructure, and facilitate recovery from disruptions to energy supplies. LANL has pioneered the development of coated conductors – high-temperature superconducting (HTS) tapes – which permit dramatically greater current densities than conventional copper cable, and enable new technologies to secure the national electric grid. Sustained world-class research from concept, demonstration, transfer, and ongoing industrial support has moved this idea from the laboratory to the commercial marketplace.

  14. Thermodynamic Study of UO3(g), UO2(OH)2(g), UO2Cl2(g), and UO2F2(g)

    SciTech Connect

    Ebbinghaus, B B; Krikorian, O H; Fleming, D L

    2002-11-07

    Using the transpiration method, the volatility of uranium oxide in the presence of oxygen and water vapor has been measured at temperatures ranging from 1173 to 1573 K and the volatility of uranium oxide in the presence of oxygen and chlorine has been measured at 1175 K. The major vapor species in the presence of oxygen and water vapor are found to be UO{sub 3}(g) and UO{sub 2}(0H){sub 2}(g). Third law treatment of the vaporization data yields {Delta}H{sub f}{sup o}(298) values of -790.52 {+-} 7.32 and -1199.94 {+-} 10.25 kJ/mol, respectively. The major vapor species in the presence of oxygen and chlorine is found to be UO{sub 2}Cl{sub 2}(g). Third law treatment of the vaporization data yields a {Delta}H{sub f}{sup o}(298) value of -1002.04 {+-} 3.26 kJ/mol. From an assessment of all the thermodynamic data available for UO{sub 3}(g), UO{sub 2}(OH){sub 2}(g), UO{sub 2}Cl{sub 2}(g), and UO{sub 2}F{sub 2}(g), the best {Delta}H{sub f{sup o}}(298) values for each of these species are calculated to be -796.74 {+-} 3.52, -1199.94 {+-} 10.25, -999.64 {+-} 2.40, and -1369.22 {+-} 2.87 kJ/mol, respectively. From these, the {Delta}H{sub f{sup o}} (298) values for UO{sub 2}ClOH(g), UO{sub 2}FOH(g), and UO{sub 2}FCl(g) are estimated to be -1099.79, -1284.58, and -1184.43 kJ/mol, respectively. The thermodynamic data for all the vapor species are then applied to conditions one might expect in a thermal oxidation processor for mixed waste to estimate the amount of uranium volatility.

  15. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application.

  16. High-Density-Tape Casting System

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1987-01-01

    Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

  17. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain. PMID:26311991

  18. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  19. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  20. Progress in research, development, and pre-commercial deployment of second generation HTS wires in the USA

    NASA Astrophysics Data System (ADS)

    Hawsey, Robert A.; Christen, David K.

    2006-10-01

    US efforts to develop and deploy "second generation" (2G) high-temperature superconducting (HTS) wires that use the compound Y1Ba2Cu3Ox (YBCO) or other rare-earth (RE) superconducting materials are described. Wires have been demonstrated in 20 to >200-m lengths with the YBCO deposited using vapor deposition or wet chemical processes in ultra-thin layers onto textured, buffered metallic templates, which forces the grains of the RE-BCO into near perfect alignment. Critical currents for these pre-commercial wires are now within striking distance of those achieved for commercial BSSCO wires. One expected advantage of 2G wire is a 5-fold decrease in the price of wire compared with first generation wires. Another advantage of 2G wire is the intrinsic behavior of YBCO in the presence of a strong magnetic field. Enhancements in flux pinning of at least a factor of two have been demonstrated for MOCVD and MOD deposited YBCO films. US progress towards meeting the challenging goals for the year 2006, including current exceeding 300 A/cm width (77 K, self-field) in 100-m lengths and engineering current density exceeding 10,000 A/cm2 (65 K, 3-T) is reported. In addition, initial efforts toward engineering the conductor for the mechanical and electrical properties needed for strong magnetic field applications are described.

  1. New energy storage concept uses tapes

    NASA Technical Reports Server (NTRS)

    Gruber, A.; Kafesjian, R. R.

    1966-01-01

    Energy storage system uses movable permeable tapes with cathode and electrolyte material that is drawn across an anode to produce electric power. The system features long shelf life, high efficiency, and flexible operation.

  2. Video Tape and the Mentally Retarded

    ERIC Educational Resources Information Center

    Weisbord, H. F.

    1972-01-01

    Three uses of video tape recordings with the mentally retarded; discussed briefly are staff training or teacher education, parental involvement in the child's education, and therapeutic uses by psychiatrists and psychologists. (CB)

  3. Operating time meter for tape recorder

    NASA Astrophysics Data System (ADS)

    Ganzburg, M.; Dyuffel, O.

    1985-03-01

    As an alternative to standard tape counters for popular tape recorders, a photo-electric device for measuring operating time so as to give a precise reading of expended and available operating time. The device consists of two optical components in a slotted cylinder attached to the rubberized free-wheeling tension wheel. The first, third and fourth discharge circuits have a calculation coefficient of 10, the second, of 6. Technical features are diagrammed and described. The three components include the mechanical tension wheel and the plate on which the light- and photodiodes are mounted, the basic meter plate and light diode indicators and related components. If quality parts are properly mounted, no calibration is required. Features of mechanical tape regulation permitting smooth monitoring of tape movement may make the photoelectric device described unnecessary.

  4. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  5. Urinary incontinence - tension-free vaginal tape

    MedlinePlus

    ... place) Damage to the urethra, bladder, or vagina Erosion of the tape into surrounding normal tissues (urethra ... told to take with a small sip of water. Your doctor or nurse will tell you when ...

  6. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  7. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability.

    PubMed

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-07-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability.

  8. Read/write head for a magnetic tape device having grooves for reducing tape floating

    DOEpatents

    Aoki, Kenji

    2005-08-09

    A read/write head for a magnetic tape includes an elongated chip assembly and a tape running surface formed in the longitudinal direction of the chip assembly. A pair of substantially spaced parallel read/write gap lines for supporting read/write elements extend longitudinally along the tape running surface of the chip assembly. Also, at least one groove is formed on the tape running surface on both sides of each of the read/write gap lines and extends substantially parallel to the read/write gap lines.

  9. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability

    PubMed Central

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-01-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability. PMID:26311206

  10. Program Documentation Report: STD Tape Copy Programs,

    DTIC Science & Technology

    Berman Model 9040 STD probe and 1014 data logger. The programs are written in FORTRAN IV and IBM 360 ASSEMBLAR COMPUTER LANGUAGES. Data tapes from the... STD in 7 track format are read in ASSEMBLAR Language and a 9 track FORTRAN readable tape produced. Printouts from the programs record the number of data points recovered and also list the bad data points (if any). (Author)

  11. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  12. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  13. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  14. THE UTILIZATION OF THE NTP-HTS DATA IN CHEMICAL TOXICITY MODELING

    EPA Science Inventory

    To explore efficient approaches to assessing the toxicity of environmental chemicals, the NIEHS National Toxicology Program (NTP) recently initiated a High Throughput Screening (HTS) Project. To date, HTS results for a set of 1,408 compounds tested in 6 cell viability assays have...

  15. Design and Development of a 100 MVA HTS Generator for Commercial Entry

    SciTech Connect

    2007-06-07

    In 2002, General Electric and the US Department of Energy (DOE) entered into a cooperative agreement for the development of a commercialized 100 MVA generator using high temperature superconductors (HTS) in the field winding. The intent of the program was to: (1) identify and develop technologies that would be needed for such a generator; (2) develop conceptual designs for generators with ratings of 100 MVA and higher using HTS technology; (3) perform proof of concept tests at the 1.5 MW level for GE's proprietary warm iron rotor HTS generator concept; and (4) design, build, and test a prototype of a commercially viable 100 MVA generator that could be placed on the power grid. This report summarizes work performed during the program and is provided as one of the final program deliverables. The design for the HTS generator was based on GE's warm iron rotor concept in which a cold HTS coil is wound around a warm magnetic iron pole. This approach for rotating HTS electrical machinery provides the efficiency benefits of the HTS technology while addressing the two most important considerations for power generators in utility applications: cost and reliability. The warm iron rotor concept uses the least amount of expensive HTS wire compared to competing concepts and builds on the very high reliability of conventional iron core stators and armature windings.

  16. Temperature regulation in rats exposed to a 2 G field

    NASA Technical Reports Server (NTRS)

    Ishihama, Linda M.; Murakami, Dean M.; Fuller, Charles A.

    1989-01-01

    The regulation of body temperature involves both homeostatic and circadian control systems. Both systems are influenced by exposure to hyperdynamic fields and demonstrate acute responses that eventually recover to an adapted level. This experiment examined both the homeostatic and circadian responses of body temperature to a separate environmental challenge (high frequency light/dark cycles) during exposure to a 2 G hyperdynamic field.

  17. Development of REBCO HTS Magnet of Magnetic Bearing for Large Capacity Flywheel Energy Storage System

    NASA Astrophysics Data System (ADS)

    Mukoyama, Shinichi; Matsuoka, Taro; Furukawa, Makoto; Nakao, Kengo; Nagashima, Ken; Ogata, Masafumi; Yamashita, Tomohisa; Hasegawa, Hitoshi; Yoshizawa, Kazuhiro; Arai, Yuuki; Miyazaki, Kazuki; Horiuchi, Shinichi; Maeda, Tadakazu; Shimizu, Hideki

    A flywheel energy storage system (FESS) is a promising electrical storage system that moderates fluctuation of electrical power from renewable energy sources. The FESS can charge and discharge the surplus electrical power repetitively with the rotating energy. Particularly, the FESS that utilizes a high temperature superconducting magnetic bearing (HTS bearing) is lower loss than conventional FESS that has mechanical bearing, and has property of longer life operation than secondary batteries. The HTS bearing consists of a HTS bulk and double-pancake coils used 2nd generation REBCO wires. In the development, the HTS double-pancake coils were fabricated and were provided for a levitation test to verify the possibility of the HTS bearing. We successfully confirmed the magnetic field was achieved to design value, and levitation force in the configuration of one YBCO bulk and five double pan-cake coils was obtained to a satisfactory force of 39.2 kN (4 tons).

  18. Application of shielding current in bulk HTS to control magnetic field distribution

    NASA Astrophysics Data System (ADS)

    Kii, T.

    2016-03-01

    Superconducting shielding current is excited when external field is applied to superconductor. In case for field cooling of bulk superconductor, shielding current is an origin of strong trapped field. When external field is changed to a properly arranged bulk HTS array, various magnetic field distribution can be formed by an excited shielding current in each bulk HTS. This paper presents a simple intuitively method to design magnetic field distribution using supercurrents in bulk high-temperature superconductor (HTS) array. In this method, an ideal current path for intended field distribution is represented by shielding currents in bulk HTS array. Expected performance can be roughly estimated by using Biot-Savart law. As examples, Maxwell coil pair and helical field generator are designed. This method can be applied to design various magnet devices using bulk HTS array.

  19. Sub-Micron Long HTS Ho Electron Mixers

    NASA Technical Reports Server (NTRS)

    Harnack, 0.; Karasik, B. S.; McGrath, W. R.; Kleinsasser, A. W.; Barner, J. B.

    2000-01-01

    The hot-electron bolometer mixer made from a high-T, superconductor (HTS) was introduced recently as an alternative to a Schottky mixer at THz frequencies. The performance of the mixer depends on the total thermal conductance for heat removal from the phonon sub-system due to either length-dependent phonon diffusion or phonon escape to the substrate. We have measured both the length and temperature dependencies of the IF bandwidth of the mixers fabricated from 25-35 mn thick YBCO films on MgO and sapphire substrates. The films were grown by a laser deposition technique and electron-beam lithography was used to define bridge lengths down to 50 nm. Mixer measurements were done using signal frequencies in the range of 1-100 GHz. For 50 nm and 400 nm long devices on MgO, the 3-dB bandwidth was about 100 MHz. At temperatures below 60 K, the hot-electron plateau was clearly seen starting around 2-3 GHz. At temperatures above 70 K, the flux-flow effects begin to dominate and the IF bandwidth increases to 1-8 GHz, while the conversion efficiency drops by several dB. This temperature dependence of the IF bandwidth can account for previously reported unexpectedly high bandwidth of HTS mixers.

  20. HTS Magnets for Advanced Magnetoplasma Space Propulsion Applications

    SciTech Connect

    Carte, M.D.; Chang-Diaz, F.R. Squire, J.P.; Schwenterly, S.W.

    1999-07-12

    Plasma rockets are being considered for both Earth-orbit and interplanetary missions because their extremely high exhaust velocity and ability to modulate thrust allow very efficient use of propellant mass. In such rockets, a hydrogen or helium plasma is RF-heated and confined by axial magnetic fields produced by coils around the plasma chamber. HTS coils cooled by the propellant are desirable to increase the energy efficiency of the system. We describe a set of prototype high-temperature superconducting (HTS) coils that are being considered for the VASIMR ( Variable Specific Impulse Magnetoplasma Rocket) thruster proposed for testing on the Radiation Technology Demonstration (RTD) satellite. Since this satellite will be launched by the Space Shuttle, for safety reasons liquid helium will be used as propellant and coolant. The coils must be designed to operate in the space environment at field levels of 1 T. This generates a unique set of requirements. Details of the overall winding geometry and current density, as well as the challenging thermal control aspects associated with a compact, minimum weight design will be discussed.

  1. 5 MJ flywheel based on bulk HTS magnetic suspension

    NASA Astrophysics Data System (ADS)

    Poltavets, V.; Kovalev, K.; Ilyasov, R.; Glazunov, A.; Maevsky, V.; Verzbitsky, L.; Akhmadyshev, V.; Shikov, A.

    2014-05-01

    Nowadays the flywheel energy storage systems (FES) are developed intensively as uninterruptible power supply (UPS) devices for on-land and transport (especially airborne) applications worldwide. This work is devoted to the FES with magnetic suspension on the base of bulk HTS YBCO elements and permanent magnets. The developed FES is intended to be used as UPS in Russian atomic industry in case of an emergency. For the successful design of the FES the following questions should be solved: design of the motor/generator, design of the rotor (flywheel), design of the bearing system, design of the control system and system of power load matching, design of the cooling system. The developed small-scale FES with the stored energy 0.5 MJ was used to solve these basic questions. The elaborated FES consists of the synchronous electric machine with permanent magnets, the solid flywheel with axial magnetic suspension on the base of YBCO bulks and permanent magnets, the system of control and power load matching, and the system of liquid nitrogen cooling. The results of theoretical modeling of different schematics of magnetic suspension and experimental investigations of the constructed FES are presented. The design of the future full-scale FES with the stored energy ~5 MJ and output power up to 100 kW is described. The test results of the flywheel rotor and HTS magnetic suspension of 5 MJ FES are presented. This work is done under support of Rosatom within the frames of Russian Project "Superconducting Industry"

  2. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  3. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    PubMed

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  4. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    PubMed Central

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  5. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  6. Locating PHEV exchange stations in V2G

    SciTech Connect

    Pan, Feng; Bent, Russell; Berscheid, Alan; Izraelevitz, David

    2010-01-01

    Plug-in hybrid electric vehicle (PREV) is an environment friendly modem transportation method and has been rapidly penetrate the transportation system. Renewable energy is another contributor to clean power but the associated intermittence increases the uncertainty in power generation. As a foreseen benefit of a vchicle-to-grid (V2G) system, PREV supporting infrastructures like battery exchange stations can provide battery service to PREV customers as well as being plugged into a power grid as energy sources and stabilizer. The locations of exchange stations are important for these two objectives under constraints from both ,transportation system and power grid. To model this location problem and to understand and analyze the benefit of a V2G system, we develop a two-stage stochastic program to optimally locate the stations prior to the realizations of battery demands, loads, and generation capacity of renewable power sources. Based on this model, we use two data sets to construct the V2G systems and test the benefit and the performance of these systems.

  7. Accelerating the introduction of HTS products for a broad range of electric power and industrial applications

    NASA Astrophysics Data System (ADS)

    Eaton, Russell

    2002-01-01

    The Department of Energy (DOE), as part of its Superconductivity Program for Electric Systems, is successfully pursuing the development of electric power and industrial devices, incorporating significant high-temperature superconducting (HTS) components or subsystems, through its innovative Superconducting Partnership Initiative (SPI). The objective of the SPI is to accelerate the commercial introduction of the HTS products for a broad range of electric power and industrial applications. DOE's approach to accomplishing the SPI objective is to support cost shared projects carried out by industry led teams. DOE will fund projects to develop HTS devices that are either in (1) the research and development stage (Phase 1), (2) the pre-commercialization stage (Phase II), or (3) the commercial entry stage (Phase III). DOE's industry partners must contribute at least half a project's costs. These teams will include capabilities needed to develop the device as well as to develop the business plan for the commercial product introduction. DOE's partners consist of vertically integrated teams consisting of equipment manufacturers, HTS wire and coil suppliers, national laboratories, and end users, primarily utilities. These partners carry out the multi-year technology development efforts, consisting generally of design, construction, and testing of the HTS system. Finally, commercialization of HTS products will be discussed primarily in terms of benefits these products will have over competing products based upon conventional conductors and the critical need for affordable, practical HTS materials and conductors for these applications. .

  8. Fabrication and test of an axial-field HTS rotating machine with integrated magnetic coupling

    NASA Astrophysics Data System (ADS)

    Dolisy, B.; Mezani, S.; Lubin, T.; Lévêque, J.

    2017-03-01

    High temperature superconducting (HTS) electrical machines have high torque density with a very high efficiency. Torque tubes are usually used to transmit the torque from the cold to the warm environment which results in thermal losses and mechanical problems. To overcome these difficulties, we propose to transmit the torque of the HTS machine through an integrated HTS magnetic coupling. A prototype has been constructed and tested showing the effectiveness of the proposed solution. The machine and the coupling share the same HTS rotor while the torque produced by the machine is transmitted to the load via a permanent magnets rotor. This solution allows the reduction of the thermal losses and a natural protection against overload during fault. The electromagnetic design is carried out using 3D finite elements (FE). The HTS material electrical behavior is described using a power law so it was possible to determine the operating current of the HTS coils of the device. Many test results such as U(I) curves of the HTS coils, static torque, back-EMF and on-load characteristics are presented and checked by the FE computations.

  9. Design Construction and Test Results of a HTS Solenoid For Energy Recovery Linac

    SciTech Connect

    Anerella, M; Ben-Zvi, I; Kayran, D; McIntyre, G; Muratore, J; Plate, S; Sampson, W; Cole, M; Holmes, D

    2011-03-28

    An innovative feature of the proposed Energy Recovery Linac (ERL) is the use of a solenoid made with High Temperature Superconductor (HTS) with the Superconducting RF cavity. The use of HTS allows solenoid to be placed in close proximity to the cavity and thus provides early focusing of the electron beam. In addition, cryogenic testing at {approx}77 K is simpler and cheaper than 4 K testing. This paper will present the design, construction and test results of this HTS solenoid. The HTS solenoid in the proposed ERL will be situated in the transition region between the superconducting cavity at {approx}4 K and the cryostat at the room temperature. Solenoid inside the cryogenic structure provides an early focusing and hence low emittance beam. The temperature in the transition region will be too high for a conventional low temperature superconductor and resistive heat load from copper coils will be too high on cryogenic system. HTS coils also allow much higher current density and significant reduction in size as compared to copper coils. Hence HTS solenoid provide a unique and technically superior solution. The use of a HTS solenoid with superconducting cavity offers a unique option as it can be placed in a cold to warm transition region to provide early focussing without using additional space. Construction and test results so far are very encouraging for its use in the ERL project.

  10. Analysis on heat loss characteristics of a 10 kV HTS power substation

    NASA Astrophysics Data System (ADS)

    Teng, Yuping; Dai, Shaotao; Song, Naihao; Zhang, Jingye; Gao, Zhiyuan; Zhu, Zhiqin; Zhou, Weiwei; Wei, Zhourong; Lin, Liangzhen; Xiao, Liye

    2014-09-01

    A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

  11. Closed Form Formulas for Distributed Circuit Model of Discontinuities in HTS Microstrip Transmission Lines

    NASA Astrophysics Data System (ADS)

    Javadzadeh, S. Mohammad Hassan; Mamaghany, Zahra Mardy; Farzaneh, Forouhar; Fardmanesh, Mehdi

    A distributed circuit model for different kinds of discontinuities in high temperature superconducting (HTS) microstrip transmission lines (TLs), is proposed. In each case, closed form formula for lumped element model is presented based on the configuration of the discontinuity and the characterizations of HTS microstrip TLs. These discontinuities consist of steps in width, open ends, gaps and 90-degree bends. In the case of normal conductor microstrip TLs there are a lot of numerical and analytical equations that can accurately model them, however those formulas are not efficient for HTS TLs. Thus modified relations are extracted utilizing the superconducting characterizations to obtain much more accurate formulas. Additionally temperature dependence of HTS TLs is considered in the relations. Moreover regarding the kinetic inductance in HTS TLs a closed form formula is proposed for characteristic impedance of HTS TLs. Furthermore correction factors based on fringe fields is used to optimize all formulas. Using these formulations can lead to modeling and analysis of some superconducting microwave devices such as resonators, microwave filters, couplers, etc. In contrast to EM analysis, using the distributed circuit model is much easier for analysis of HTS microwave devices. The accuracy of the proposed model is confirmed in comparison with some electromagnetic full-wave simulations. This full analytical approach shows great accuracy in this test case as well.

  12. Electrical machines with bulk HTS elements.. The achieved results and future development

    NASA Astrophysics Data System (ADS)

    Kovalev, L. K.; Ilushin, K. V.; Penkin, V. T.; Kovalev, K. L.; Koneev, S. M.-A.; Modestov, K. A.; Larionoff, S. A.; Gawalek, W.; Oswald, B.

    2001-09-01

    Novel types of electric HTS motors with the rotor containing bulk YBCO and Bi-Ag elements are presented. Different schematics of hysteresis, reluctance “trapped field” and composed HTS motors are discussed. Two-dimensional mathematical models describing the processes in these types of HTS machines were developed on the basis of a theoretical analysis of the electrodynamic and hysteresis processes in multi-domain and single-domain HTS ceramic samples. The test results of these HTS motors with output power 1-37 kW and current frequencies 50 and 400 Hz are given. The results show that in liquid nitrogen the specific output power per one weight unit is 4-5 times better then for conventional electric machines. The design of a new high power HTS motor operating in the liquid nitrogen with output power 200 kW (and more) is discussed. Future applications of new types of HTS motors for airspace and on-land industry and transport systems are discussed.

  13. Using magnetic tape technology for data migration

    NASA Technical Reports Server (NTRS)

    Therrien, David; Cheung, Yim-Ling

    1993-01-01

    Magnetic tape and optical disk library units (jukeboxes) are satisfying the demand for high-capacity cost-effective storage. The choice between optical disk and magnetic tape technology must take into account the cost limitations as well as the performance and reliability requirements of the user environment. Library units require data management software in order to function in an automated and user-transparent way. The most common data management applications are backup and recovery, data migration, and archiving. The medium access patterns that these applications create will be described. Since the most user visible application is data migration, a queue simulator was developed to model its performance against a variety of library units. The major subject of this paper is the design and implementation of this simulator as well as some simulation results. The relative cost and reliability of magnetic tape versus optical disk library units is presented for completeness.

  14. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  15. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  16. Thermal property of insulation material for HTS power cable

    NASA Astrophysics Data System (ADS)

    Choi, Yeon Suk; Kim, D. L.; Shin, D. W.; Hwang, S. D.

    2012-06-01

    The thermal property of insulation material is essential in developing a high temperature superconductor (HTS) power cable operating at around liquid nitrogen temperature. The accurate estimate of the heat flux is difficult in the nonmetallic materials because nonmetallic materials have a high thermal resistance and low temperature gradient along the specimen. The objective of the present work is to develop a precise instrument for measuring the thermal conductivity of insulating materials over a temperature range of 30 K to approximately the room temperature by using a cryocooler. The thermal conductivity of Teflon is measured and the accuracy confirmation is carried out by comparing published data. In addition, the experimental results of apparent thermal conductivity of polypropylene laminated paper (PPLP) are presented and the temperature dependency is also discussed

  17. Electrical and Mechanical Characterizations of Nanocomposite Insulation for HTS Systems

    SciTech Connect

    Walsh, J K; Fabian, Paul E; Hooker, M W; Lizotte, M J; Tuncer, Enis; Sauers, Isidor

    2011-01-01

    As HTS wire technology continues to advance, a critical need has emerged for dielectric materials that can be used in superconducting components such as terminations, fault current limiters, transformers, and motors. To address this need, CTD is developing nanocomposite insulations based on epoxy and benzoxazine chemistries. Depending on part geometry, some processing methods are more efficient than others. For this reason, CTD is investigating both fiber-reinforced and filled resin systems for use in these applications. A thorough set of electrical testing including AC breakdown, breakdown as a function of thickness, and flashover shows promising performance characteristics. In addition, mechanical testing (short beam shear and compression) indicate that these new materials to have as good or better performance than G10.

  18. Magnetizing of permanent magnets using HTS bulk magnets

    NASA Astrophysics Data System (ADS)

    Oka, Tetsuo; Muraya, Tomoki; Kawasaki, Nobutaka; Fukui, Satoshi; Ogawa, Jun; Sato, Takao; Terasawa, Toshihisa

    2012-01-01

    A demagnetized Nd-Fe-B permanent magnet was scanned just above the magnetic pole which contains the HTS bulk magnet generating a magnetic field of 3.27 T. The magnet sample was subsequently found to be fully magnetized in the open space of the static magnetic fields. We examined the magnetic field distributions when the magnetic poles were scanned twice to activate the magnet plate inversely with various overlap distances between the tracks of the bulk magnet. The magnetic field of the "rewritten" magnet reached the values of the magnetically saturated region of the material, showing steep gradients at the border of each magnetic pole. As a replacement for conventional pulse field magnetizing methods, this technique is proposed to expand the degree of freedom in the design of electromagnetic devices, and is proposed as a novel practical method for magnetizing rare-earth magnets, which have excellent magnetic performance and require intense fields of more than 3 T to be activated.

  19. Analytical Study of Stress State in HTS Solenoids

    SciTech Connect

    Barzi, E.; Terzini, E.; /Fermilab

    2009-01-01

    A main challenge for high field solenoids made of in High Temperature Superconductor (HTS) is the large stress developed in the conductor. This is especially constraining for BSCCO, a brittle and strain sensitive ceramic material. To find parametric correlations useful in magnet design, analytical models can be used. A simple model is herein proposed to obtain the radial, azimuthal and axial stresses in a solenoid as a function of size, i.e. self-field, and of the engineering current density for a number of different constraint hypotheses. The analytical model was verified against finite element modeling (FEM) using the same hypotheses of infinite rigidity of the constraints and room temperature properties. FEM was used to separately evaluate the effect of thermal contractions at 4.2 K for BSCCO and YBCO coils. Even though the analytical model allows for a finite stiffness of the constraints, it was run using infinite stiffness. For this reason, FEM was again used to determine how much stresses change when considering an outer stainless steel skin with finite rigidity for both BSCCO and YBCO coils. For a better understanding of the actual loads that high field solenoids made of HTS will be subject to, we have started some analytical studies of stress state in solenoids for a number of constraint hypotheses. This will hopefully show what can be achieved with the present conductor in terms of self-field. The magnetic field (B) exerts a force F = B x J per unit volume. In superconducting magnets, where the field and current density (J) are both high, this force can be very large, and it is therefore important to calculate the stresses in the coil.

  20. Effects of Kinesio taping and Mcconnell taping on balance and walking speed of hemiplegia patients

    PubMed Central

    Choi, Yong-Kyu; Park, Young-Han; Lee, Jung-Ho

    2016-01-01

    [Purpose] The aim of this study was to evaluate the overlap effect of the PNF following the application of Kinesio taping and the McConnell taping, and also the impact of the taping application method on the balance and walking speed of the patients with stroke. [Subjects and Methods] Thirty-six patients who were diagnosed with hemiplegia due to stroke were selected as subjects of this study. They were randomly and evenly divided into experiment group 1 (Kinesio taping group), experiment group 2 (McConnell taping group), and the control group; each group had 12 patients. [Results] The Berg balance scale (BBS) was used to evaluate balance, and the ability in this study. A 10 m walking test (10MWT) was performed to measure the walking speed. Experiment group 1 showed a statistically significant improvement in balance and walking speed compared to experiment group 2, and the control group in week 4 and week 8. [Conclusion] Application of Kinesio taping had a more beneficial effect on the balance and walking speed than joint-fixation taping of the patients with stroke. PMID:27190448

  1. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  2. Simulation and measurement of a Ka-band HTS MMIC Josephson junction mixer

    NASA Astrophysics Data System (ADS)

    Zhang, Ting; Pegrum, Colin; Du, Jia; Guo, Yingjie Jay

    2017-01-01

    We report modeling and simulation results for a Ka band high-temperature superconducting (HTS) monolithic microwave integrated circuit (MMIC) Josephson junction mixer. A Verilog-A model of a Josephson junction is established and imported into the system simulator to realize a full HTS MMIC circuit simulation containing the HTS passive circuit models. Impedance matching optimization between the junction and passive devices is investigated. Junction DC I-V characteristics, current and local oscillator bias conditions and mixing performance are simulated and compared with the experimental results. Good agreement is obtained between the simulation and measurement results.

  3. Long Term Operation of Cooling System for the Kepco Hts Power Cable

    NASA Astrophysics Data System (ADS)

    Yang, H. S.; Kim, D. L.; Sohn, S. H.; Lim, J. H.; Choi, Y. S.; Hwang, S. D.

    2010-04-01

    HTS power cable systems of to several hundred meters in length are presently being developed and evaluated for practical use in real power grids. Since 2006, a cooling system for the 3-phase, 100-m HTS power cable with 22.9 kV/1.25 kA has been installed and tested at the KEPCO's Gochang power-testing center. Performance reliability through several demonstration tests of over 9,000 hours was demonstrated. This paper mainly describes the cooling performance test results of the HTS power cable system obtained during the long-term performance tests.

  4. Static and dynamic stability of the guidance force in a side-suspended HTS maglev system

    NASA Astrophysics Data System (ADS)

    Zhou, Dajin; Cui, Chenyu; Zhao, Lifeng; Zhang, Yong; Wang, Xiqing; Zhao, Yong

    2017-02-01

    The static and dynamic stability of the guidance force in a side-suspended HTS-PMG (permanent magnetic guideway) system were studied theoretically and experimentally. It is found that there are two types of guidance force that exist in the HTS-PMG system, which are sensitive to the levitation gap and the arrangement of YBCO bulks around the central axis of the PMG. An optimized YBCO array was used to stabilize the system, which enabled a side-suspended HTS-PMG maglev vehicle to run stably at 102 km h-1 on a circular test track with 6.5 m in diameter.

  5. The electrical characteristics of solid insulators for 154 kV class HTS transformer

    NASA Astrophysics Data System (ADS)

    Cheon, H. G.; Choi, J. H.; Pang, M. S.; Kim, W. J.; Kim, S. H.

    2011-11-01

    HTS transformer, without any loss of insulation lifetime due to the reduction in terms of size and weight, can increase the overload capacity, and have some benefits such as the improvement in efficiency, minimization of environmental pollution, and convenient spatial arrangement, which contribute a lot to electric power system operation. However, for practical insulation design of the HTS transformer, it is necessary to establish the research on electrical properties LN2 as well as solid insulators. These solid insulators have been used as main insulations for HTS transformer. In this paper, we discussed breakdown and V-t characteristics of glass fiber reinforced plastics (GFRP) and pressboard in LN2.

  6. Development of Coated Conductors in Japanese National Project "Development of Fundamental Technologies for HTS Coils"

    NASA Astrophysics Data System (ADS)

    Yoshizumi, Masateru; Izumi, Teruo; Shiohara, Yuh

    RE1Ba2Cu3O7-x (REBCO, RE=rare earth) coated conductors have attracted the attention of many scientists due to the high superconducting properties, etc. Due to the great progress of R&D on coated conductors, the activities have shifted to specific applications. The new Japanese national project, named as "Development of Fundamental Technologies for HTS Coils", started last year aiming for the applications of MRI and medical accelerators. To meet the requirements of those applications, the R&D of REBCO coated conductors (CCs) are being performed with that of coiling technology in parallel. The theme has two sub-themes of "development of long CCs with high in-field performance" and "development of CCs with extremely low heat generation" in this national project. The ambitious goals of these themes are set as intermediate ones due 2016 Mar; the theme of in-field: 100m-500A/cm-w@65K, 3T -850A/cm-w@35K, 10T, the theme of low heat generation: 100m-500 μm of filament width w/ Icfilament inhomogeneity of distribution within 10% and joint resistance below 5nΩ. The final goals of these themes due 2018 Mar. were set as follows; the theme of in-field: 200m-600A/cm-w@65K, 3T -1000A/cm-w@35K, 10T, the theme of low heat generation: 200m-500 μm of filament width w/ Icfilament distribution within 5% and joint resistance below 3nΩ. The objectives, goals and progress of this project will be reviewed in this article. As for the progress, for example, the combination of EuBCO+BHO was found to be effective to improve the in-field performance of PLD derived coated conductors. A 94 m long wire with Icmin of 108A/cm-w@77K, 3T (corresponding to 472A/cm-w @65K, 3T) was successfully fabricated. It is as twice Icmin of the long tape as the highest one in the previous project.

  7. Development of sensory motor reflexes in 2 G exposed rats.

    PubMed

    Wubbels, Réne; Bouët, Valentine; de Jong, Herman; Gramsbergen, Albert

    2004-07-01

    During gestation and early postnatal development, the animal's size and weight rapidly increase. Within that period, gravity affects sensory and motor development. We studied age-dependent modifications of several types of motor reflexes in 5 groups of rats conceived, born and reared in hypergravity (HG; 2 g). These rats were transferred to normal gravity (NG; 1 g) at various postnatal days, and their behavioral reflexes were compared with a control group which was constantly kept under NG. HG induced a retarded development of vestibular dependent reflexes. Other types of motor behavior were not delayed.

  8. Elastic therapeutic tape: do they have the same material properties?

    PubMed Central

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-01-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex®, ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight® 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young’s modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young’s modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape. PMID:27190472

  9. Elastic therapeutic tape: do they have the same material properties?

    PubMed

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-04-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex(®), ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight(®) 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young's modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young's modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape.

  10. Engineered pinning landscapes for enhanced 2G coil wire

    DOE PAGES

    Rupich, Martin W.; Sathyamurthy, Srivatsan; Fleshler, Steven; ...

    2016-04-01

    We demonstrate a twofold increase in the in-field critical current of AMSC's standard 2G coil wire by irradiation with 18-MeV Au ions. The optimum pinning enhancement is achieved with a dose of 6 × 1011 Au ions/cm2. Although the 77 K, self-field critical current is reduced by about 35%, the in-field critical current (H//c) shows a significant enhancement between 4 and 50 K in fields > 1 T. The process was used for the roll-to-roll irradiation of AMSC's standard 46-mm-wide production coated conductor strips, which were further processed into standard copper laminated coil wire. The long-length wires show the samemore » enhancement as attained with short static irradiated samples. The roll-to-roll irradiation process can be incorporated in the standard 2G wire manufacturing, with no modifications to the current process. In conclusion, the enhanced performance of the wire will benefit rotating machine and magnet applications.« less

  11. Engineered pinning landscapes for enhanced 2G coil wire

    SciTech Connect

    Rupich, Martin W.; Sathyamurthy, Srivatsan; Fleshler, Steven; Li, Qiang; Solovyov, Vyacheslav; Ozaki, Toshinori; Welp, Ulrich; Kwok, Wai -Kwong; Leroux, Maxime; Koshelev, Alexei E.; Miller, Dean J.; Kihlstrom, Karen; Civale, Leonardo; Eley, Serena; Kayani, Asghar

    2016-04-01

    We demonstrate a twofold increase in the in-field critical current of AMSC's standard 2G coil wire by irradiation with 18-MeV Au ions. The optimum pinning enhancement is achieved with a dose of 6 × 1011 Au ions/cm2. Although the 77 K, self-field critical current is reduced by about 35%, the in-field critical current (H//c) shows a significant enhancement between 4 and 50 K in fields > 1 T. The process was used for the roll-to-roll irradiation of AMSC's standard 46-mm-wide production coated conductor strips, which were further processed into standard copper laminated coil wire. The long-length wires show the same enhancement as attained with short static irradiated samples. The roll-to-roll irradiation process can be incorporated in the standard 2G wire manufacturing, with no modifications to the current process. In conclusion, the enhanced performance of the wire will benefit rotating machine and magnet applications.

  12. Engineered Pinning Landscapes for Enhanced 2G Coil Wire

    DOE PAGES

    Rupich, Martin W.; Sathyamurthy, Srivatsan; Fleshler, Steven; ...

    2016-03-15

    In this study, we demonstrate a twofold increase in the in-field critical current of AMSC's standard 2G coil wire by irradiation with 18-MeV Au ions. The optimum pinning enhancement is achieved with a dose of 6 × 1011 Au ions/cm2. Although the 77 K, self-field critical current is reduced by about 35%, the in-field critical current (H//c) shows a significant enhancement between 4 and 50 K in fields > 1 T. The process was used for the roll-to-roll irradiation of AMSC's standard 46-mm-wide production coated conductor strips, which were further processed into standard copper laminated coil wire. The long-length wiresmore » show the same enhancement as attained with short static irradiated samples. The roll-to-roll irradiation process can be incorporated in the standard 2G wire manufacturing, with no modifications to the current process. Finally, the enhanced performance of the wire will benefit rotating machine and magnet applications.« less

  13. Engineered Pinning Landscapes for Enhanced 2G Coil Wire

    SciTech Connect

    Rupich, Martin W.; Sathyamurthy, Srivatsan; Fleshler, Steven; Li, Qiang; Solovyov, Vyacheslav; Ozaki, Toshinori; Welp, Ulrich; Kwok, Wai-Kwong; Leroux, Maxime; Koshelev, Alexei E.; Miller, Dean J.; Kihlstrom, Karen; Civale, Leonardo; Eley, Serena; Kayani, Asghar

    2016-03-15

    In this study, we demonstrate a twofold increase in the in-field critical current of AMSC's standard 2G coil wire by irradiation with 18-MeV Au ions. The optimum pinning enhancement is achieved with a dose of 6 × 1011 Au ions/cm2. Although the 77 K, self-field critical current is reduced by about 35%, the in-field critical current (H//c) shows a significant enhancement between 4 and 50 K in fields > 1 T. The process was used for the roll-to-roll irradiation of AMSC's standard 46-mm-wide production coated conductor strips, which were further processed into standard copper laminated coil wire. The long-length wires show the same enhancement as attained with short static irradiated samples. The roll-to-roll irradiation process can be incorporated in the standard 2G wire manufacturing, with no modifications to the current process. Finally, the enhanced performance of the wire will benefit rotating machine and magnet applications.

  14. An Inexpensive, Easy to Build Slide-Tape Programmer

    ERIC Educational Resources Information Center

    Lukas, Terrence

    1975-01-01

    This article discusses the construction and use of a slide/tape programer that is simple to build and use, costs a fraction of the cheapest commercial models, and can be used with any tape recorder/player. (Author)

  15. FGGE/SMMR-30 tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/SMMR-30 tape which contains sea ice concentration data in 30 km resolution which are extracted and reformatted from Nimbus-7 SMMR PARM-30 tapes in accordance with the FGGE level II International Exchange Format Specification is outlined. There are three types of files on a FGGE/SMMR-30 tape. The first file on the tape is a test file. The second file on the tape is a tape header file. The remaining one or more files are data files. All files are terminated with a single end of file (EOP) tape mark. The last file is terminated with two EOF tape marks. All files are made up of one or more physical records. Each physical record contains 2960 bytes. Each data file contains all available values for a 6 hour synoptic time period.

  16. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  17. Red Tape: Its Origins, Uses, and Abuses.

    ERIC Educational Resources Information Center

    Kaufman, Herbert

    Red tape, particularly with reference to administration in the federal government, is described, and suggestions that have been proposed for improvement are explored. Among the frustrations that are met in dealing with government are duplicative and contradictory requirements of different agencies, restrictions imposed for announced ends that are…

  18. Tape Recording and the End Product.

    ERIC Educational Resources Information Center

    England, A. W.

    1970-01-01

    Intended to provide intense and immediate classroom experiences, tape recording projects of students can take several different forms: (1) unscripted plays and improvised situations (e.g., such "biographies" as "The Life of Charlie MacHerckumdingle: An Awkward Cuss"); (2) plays based on stories or poems (e.g., dramatizations of episodes from "The…

  19. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  20. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  1. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  2. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  3. Carbon Nanotube-Based Synthetic Gecko Tapes

    NASA Astrophysics Data System (ADS)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  4. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  5. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game,…

  6. Directory of Federal Agency Education Data Tapes.

    ERIC Educational Resources Information Center

    Feller, Barbara A.

    This directory is the initial result of a Congressional mandate to the National Center for Education Statistics (NCES) to improve coordination among Federal agencies concerned with the collection and use of education data. It identifies and describes education data bases, predominantly quantitiative, available on computer tape from Federal…

  7. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  8. Magnetic Forces Simulation of Bulk HTS over Permanent Magnetic Railway with Numerical Method

    NASA Astrophysics Data System (ADS)

    Lu, Yiyun; Zhuang, Shujun

    2012-10-01

    Magnetic levitation forces of bulk high temperature superconductor (HTS) above two types permanent magnet railway (PMR) is simulated using finite element method (FEM). The models are formulated by H-formulation and resolving codes is developed using Finite Element Program Generator (FEPG). The E- J power law is used to describe the electrical field vs. current density nonlinear characteristic of HTS. The applied magnetic fields induced by the PMR are calculated by the standard analysis method with the equivalent surface current model. By the method, the calculation formulation of magnetic fields generated by Halbach PMR and symmetrical PMR is derived respectively. The simulation results show that the finite element dynamic mesh rebuilding problem of HTS magnetic levitation transportation system comprised of bulk HTS and PMR can be easily avoided by the methods.

  9. Transient analysis of an HTS DC power cable with an HVDC system

    NASA Astrophysics Data System (ADS)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun; Yang, Byeongmo

    2013-11-01

    The operational characteristics of a superconducting DC power cable connected to a highvoltage direct current (HVDC) system are mainly concerned with the HVDC control and protection system. To confirm how the cable operates with the HVDC system, verifications using simulation tools are needed. This paper presents a transient analysis of a high temperature superconducting (HTS) DC power cable in connection with an HVDC system. The study was conducted via the simulation of the HVDC system and a developed model of the HTS DC power cable using a real time digital simulator (RTDS). The simulation was performed with some cases of short circuits that may have caused system damage. The simulation results show that during the faults, the quench did not happen with the HTS DC power cable because the HVDC controller reduced some degree of the fault current. These results could provide useful data for the protection design of a practical HVDC and HTS DC power cable system.

  10. Design, development and calibration of HTS wire based LOX level sensor probe

    NASA Astrophysics Data System (ADS)

    Karunanithi, R.; Jacob, S.; Nadig, D. S.; Prasad, M. V. N.; Gour, A. S.; Gowthaman, M.; Deekshith, P.; Shrivastava, V.

    2014-01-01

    For space applications, the weight of the liquid level sensors are of major concern as they affect the payload fraction and hence the cost. An attempt is made to design and test a light weight High Temperature Superconductor (HTS) wire based liquid level sensor for Liquid Oxygen (LOX) tank used in the cryostage of the spacecraft. The total resistance value measured of the HTS wire is inversely proportional to the liquid level. A HTS wire (SF12100) of 12mm width and 2.76m length without copper stabilizer has been used in the level sensor. The developed HTS wire based LOX level sensor is calibrated against a discrete diode array type level sensor. Liquid Nitrogen (LN2) and LOX has been used as cryogenic fluid for the calibration purpose. The automatic data logging for the system has been done using LabVIEW11. The net weight of the developed sensor is less than 1 kg.

  11. Full tape thickness feature conductors for EMI structures

    DOEpatents

    Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.; Barner, Gregory

    2014-06-10

    Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.

  12. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  13. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  14. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  15. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  16. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape...

  17. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical magnetic tape recorder. 870.2800 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800 Medical magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  18. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape...

  19. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  20. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  1. Mechanism of thickness dependence of critical current density in HTS YBCO film and its elimination using nano-engineering

    NASA Astrophysics Data System (ADS)

    Wang, Xiang

    The most promising characteristic of a High Temperature Superconductor (HTS) is its ability to carry larger electrical current at liquid nitrogen boiling temperature and strong applied magnetic field with minimal dissipation. Numerous large scale applications such as HTS transmission cables, HTS magnets and HTS motors have been developed using HTS materials. The major limitation that prevents its wide commercialization is its high cost-to-performance ratio. However, the effort to further improve HTS current carrying capability is jeopardized by a mysterious thickness dependence of the critical current density (Jc) --- Jc monotonically decreases with increasing thickness (t) at 77 K and self-field (SF). This poses a great challenge for both HTS applications and the understanding of vortex dynamics. What further complicates this issue is the complex defect structure in HTS films as well as the creep nature of magnetic vortices at a finite temperature. After a systematic study of the temperature and magnetic field effects on Jc--t, we conclude that Jc--t is most likely the result of a collective pinning effect dictated by a random pinning potential. Besides that, thermal fluctuations also alter Jc--t in a predictable way. Therefore, by either modifying the vortex structure or pinning structure, J c--t can be eliminated. Indeed, a thin film J c has been restored in a HTS/insulator/HTS trilayer while the magnetic coupling is weakened. Moreover, Jc--t has been removed when the random distributed point pins are overpowered by strong linear defects.

  2. High Temperature Superconductivity Space Experiment (HTSSE). Hybrid HTS/Dielectric Resonator Bandpass Filter

    DTIC Science & Technology

    1992-04-02

    enlarged ( limited by waveguide moding) or the metal walls replaced by HTS material . HTS walls are particularly attractive since they can be placed...an order of magnitude the resistive losses of filters, waveguide feeds, and transmission lines. Significant reduction in size and weight of these...suspending a dielectric resonator inside a waveguide cavity below cutoff. One of the basic advantages of a dielectric resonator as compared to a

  3. Cryogenic Cooling System for 5 kA, 200 μH Class HTS DC Reactor

    NASA Astrophysics Data System (ADS)

    Park, Heecheol; Kim, Seokho; Kim, Kwangmin; Park, Minwon; Park, Taejun; Kim, A.-rong; Lee, Sangjin

    DC reactors, made by aluminum busbar, are used to stabilize the arc of an electric furnace. In the conventional arc furnace, the transport current is several tens of kilo-amperes and enormous resistive loss is generated. To reduce the resistive loss at the DC reactor, a HTS DC reactor can be considered. It can dramatically improve the electric efficiency as well as reduce the installation space. Similar with other superconducting devices, the HTS DC reactor requires current leads from a power source in room temperature to the HTS coil in cryogenic environment. The heat loss at the metal current leads can be minimized through optimization process considering the geometry and the transport current. However, the transport current of the HTS DC reactor for the arc furnace is much larger than most of HTS magnets and the enormous heat penetration through the current lead should be effectively removed to keep the temperature around 70∼77 K. Current leads are cooled down by circulation of liquid nitrogen from the cooling system with a stirling cryocooler. The operating temperature of HTS coil is 30∼40 K and circulation of gaseous helium is used to remove the heat generation at the HTS coil. Gaseous helium is transported through the cryogenic helium blower and a single stage GM cryocooler. This paper describes design and experimental results on the cooling system for current leads and the HTS coil of 5 kA, 200 μH class DC reactor as a prototype. The results are used to verify the design values of the cooling systems and it will be applied to the design of scale-up cooling system for 50 kA, 200 μH class DC reactor.

  4. Cubic interaction parameters for t2g Wannier orbitals

    NASA Astrophysics Data System (ADS)

    Ribic, T.; Assmann, E.; Tóth, A.; Held, K.

    2014-10-01

    Many-body calculations for multi-orbital systems at present typically employ Slater or Kanamori interactions which implicitly assume a full rotational invariance of the orbitals, whereas the real crystal has a lower symmetry. In cubic symmetry, the low-energy t2g orbitals have an on-site Kanamori interaction, albeit without the constraint U =U'+2J implied by spherical symmetry (U is the intra-orbital interaction, U' is the interorbital interaction, J is Hund's exchange). Using maximally localized Wannier functions we show that deviations from the standard, spherically symmetric interactions are indeed significant for 5d orbitals (˜25% for BaOsO3; ˜12% if screening is included) but are less important for 3d orbitals (˜6% for SrVO3; ˜1% if screened).

  5. Effects of balance taping using kinesiology tape in a patient with moderate hallux valgus

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    Abstract Background: Hallux valgus, an increased angle of lateral deviation in the big toe, can cause pain and difficulties in balancing and walking. This study aimed to investigate the effects of balance taping using elastic therapeutic tape on moderate hallux valgus. Methods: When she walked with shoes, she complained of pain over the medial eminence of the hallux metatarsophalangeal (MTP) joint. Balance taping using kinesiology tape was applied for 3 months (average, 16hours/d) to both big toes of a 26-year-old woman with moderate hallux valgus. Results: On the right side, the hallux valgus angle (HVA) decreased from 21° to 14° and the intermetatarsal angle (IMA) decreased from 15° to 14.5°. On the left side, the HVA decreased from 22° to 11° and the IMA decreased from 15° to 12°. Furthermore, the patient was able to walk long distances in shoes without pain in the medial eminence of the hallux metatarsophalangeal joint. Conclusion: This study suggested that repeated balance taping with kinesiology tape could be used as a complementary treatment method for moderate hallux valgus. PMID:27861365

  6. Effects of Tape and Exercise on Dynamic Ankle Inversion

    PubMed Central

    Ricard, Mark D.; Sherwood, Stephen M.; Schulthies, Shane S.; Knight, Kenneth L.

    2000-01-01

    Objective: To compare the effects of tape, with and without prewrap, on dynamic ankle inversion before and after exercise. Design and Setting: Doubly multivariate analyses of variance were used to compare the taping and exercise conditions. Subjects were randomly assigned to a fixed treatment order as determined by a balanced latin square. The independent variables were tape application (no tape, tape with prewrap, tape to skin) and exercise (before and after). The dependent variables were average inversion velocity, total inversion, maximum inversion velocity, and time to maximum inversion. Subjects: Thirty college-age male and female students (17 males, 13 females; mean age = 24.9 ± 4.3 years, range, 19 to 39 years) were tested. Subjects were excluded from the study if they exhibited a painful gait or painful range of motion or had a past history of ankle surgery or an ankle sprain within the past 4 weeks. Measurements: We collected data using electronic goniometers while subjects balanced on the right leg on an inversion platform tilted about the medial-lateral axis to produce 15° of plantar flexion. Sudden ankle inversion was induced by pulling the inversion platform support, allowing the platform support base to rotate 37°. Ten satisfactory trials were recorded on the inversion platform before and after a prescribed exercise bout. We calculated total inversion, time to maximum inversion, average inversion velocity, and maximum inversion velocity after sudden inversion. Results: We found no significant differences between taping to the skin and taping over prewrap for any of the variables measured. There were significant differences between both taping conditions and no-tape postexercise for average inversion velocity, maximum inversion, maximum inversion velocity, and time to maximum inversion. The total inversion mean for no-tape postexercise was 38.8° ± 6.3°, whereas the means for tape and skin and for tape and prewrap were 28.3° ± 4.6° and 29.1°

  7. Development and construction of an HTS rotor for ship propulsion application

    NASA Astrophysics Data System (ADS)

    Nick, W.; Frank, M.; Kummeth, P.; Rabbers, J. J.; Wilke, M.; Schleicher, K.

    2010-06-01

    A low-speed high-torque HTS machine is being developed at Siemens on the basis of previous steps (400kW demonstrator, 4MVA generator). The goal of the programme is to utilize the characteristic advantages offered by electrical machines with HTS-excited rotor, such as efficiency, compact size, and dynamic performance. To be able to address future markets, requirements from ship classification as well as potential customers have to be met. Electromagnetic design cannot be focused on nominal operation only, but has to deal with failure modes like short circuit too. Utilization of superconductor requires to consider margins taking into account that the windings have to operate reliably not only in "clean" laboratory conditions, but in rough environment with the stator connected to a power converter. Extensive quality control is needed to ensure homogenous performance (current capacity, electrical insulation, dimensions) for the large quantity of HTS (45 km). The next step was to set up and operate a small-scale "industrial" manufacturing process to produce HTS windings in a reproducible way, including tests at operating conditions. A HTS rotor includes many more components compared to a conventional one, so tough geometric tolerances must be met to ensure robust performance of the system. All this gives a challenging task, which will be concluded by cold testing of the rotor in a test facility. Then the rotor will be delivered for assembly to the stator. In following machine tests the performance of the innovative HTS drive system will be demonstrated.

  8. Selection of an adhesive tape suitable for forensic fiber sampling.

    PubMed

    De Wael, Kris; Gason, Fabrice G C S J; Baes, Christiaan A V

    2008-01-01

    Five commercial adhesive tapes were tested for fiber uptake and saturation, for recovery and for ease of analysis. On the basis of the results, a high tack adhesive tape has been selected to be used for forensic fiber sampling. This adhesive tape is used as sampling material in two different micro trace kits. The first tape lifting kit is used mainly for the sampling of cars and the second is a 1:1 tape lifting kit for the collection of fibers on a corpse.

  9. First order sigma-delta modulator in HTS bicrystal technology

    NASA Astrophysics Data System (ADS)

    Ruck, B.; Chong, Y.; Dittmann, R.; Siegel, M.

    1999-11-01

    We have designed, fabricated and successfully tested a first-order sigma-delta modulator using a High-Temperature Superconducting (HTS) multi-layer technology with bicrystal Josephson junctions. The circuit has been fabricated on an SrTiO 3 bicrystal substrate. The trilayer was fabricated by laser deposition and high-pressure sputtering. The bottom layer served as a superconducting groundplane. The Josephson junctions were formed at the bicrystal line in the upper layer. The integrator resistance has been made from a Pd/Au thin film. The circuit consists of a Single Flux Quantum (SFQ) pulse generator, a Josephson transmission line (JTL), a comparator, an integrator and an output stage. The correct operation of the modulator has been tested using dc and low frequency ac measurements. The linearity of the modulator was studied by measuring the harmonic distortions of a 19.5 kHz sine wave input signal. From the recorded spectrum, a minimum resolution of at least 6 bits can be estimated. This accuracy was limited by the noise of the preamplifier. The correct operation of the current feedback loop was demonstrated by cutting the feedback inductance.

  10. Large Coaxial Coldfinger Ptc for Process Liquefaction and Hts Applications

    NASA Astrophysics Data System (ADS)

    Spoor, P. S.; Corey, J. A.

    2010-04-01

    Large (>100 W cooling capacity at 80 K) `pulse-tube' coolers are ideal candidates for emerging applications such as HTS transmission lines, transformers, and motor windings, meso-scale oxygen liquefaction on-demand, cryopumping, and cryogen boiloff recovery. A number of successful large `in-line' pulse-tube coolers have been built, but these require embedded shell-and-tube process heat exchangers, hence transport of the process fluid/gas to and from the coldhead, and often a high degree of process fluid purity, to avoid clogging in the narrow inlets and outlets of these heat exchangers. It is far preferable in most circumstances to have a coldfinger design that presents a salient cold tip, with the coldhead at the end of a flexible transfer line, as is done with Gifford-McMahon or Joule-Thomson coolers. This paper presents some design details and data from the development of our first high-capacity coldfinger, as well as the results of its application to a 55 gallon/day oxygen liquefier for the Navy.

  11. Development of High Capacity Split Stirling Cryocooler for HTS

    NASA Astrophysics Data System (ADS)

    Yumoto, Kenta; Nakano, Kyosuke; Hiratsuka, Yoshikatsu

    Sumitomo Heavy Industries, Ltd. (SHI) developed a high-power Stirling-type pulse tube cryocooler for cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES), and fault current limiters. The experimental results of a prototype pulse tube cryocooler were reported in September 2013. For a U-type expander, the cooling capacity was 151 W at 70 K with a compressor input power of 4 kW. Correspondingly, the coefficient of performance (COP) was about 0.038. However, the efficiency of the cryocooler is required to be COP > 0.1 and it was found that, theoretically, it is difficult to further improve the efficiency of a pulse tube cryocooler because the workflow generated at the hot end of the pulse tube cannot be recovered. Therefore, it was decided to change the expander to a free-piston type from a pulse tube type. A prototype was developed and preliminary experiments were conducted. A cooling capacity of 120 W at 70 K with a compressor input power of 2.15 kW with corresponding COP of 0.056, was obtained. The detailed results are reported in this paper.

  12. Neon turbo-Brayton cycle refrigerator for HTS power machines

    NASA Astrophysics Data System (ADS)

    Hirai, Hirokazu; Hirokawa, M.; Yoshida, Shigeru; Nara, N.; Ozaki, S.; Hayashi, H.; Okamoto, H.; Shiohara, Y.

    2012-06-01

    We developed a prototype turbo-Brayton refrigerator whose working fluid is neon gas. The refrigerator is designed for a HTS (High Temperature Superconducting) power transformer and its cooling power is more than 2 kW at 65 K. The refrigerator has a turboexpander and a turbo-compressor, which utilize magnetic bearings. These rotational machines have no rubbing parts and no oil-components. Those make a long maintenance interval of the refrigerator. The refrigerator is very compact because our newly developed turbo-compressor is volumetrically smaller than a displacement type compressor in same operating specification. Another feature of the refrigerator is a wide range operation capability for various heat-loads. Cooling power is controlled by the input-power of the turbo-compressor instead of the conventional method of using an electric heater. The rotational speed of the compressor motor is adjusted by an inverter. This system is expected to be more efficient. We show design details, specification and cooling test results of the new refrigerator in this paper.

  13. Energy Data Base: output magnetic tape description

    SciTech Connect

    Busse, A.E.

    1982-06-01

    This document describes a format for disseminating bibliographic citations, abstracts and subject content indicators for energy information on computer readable magnetic tape issued after July 1976. The magnetic tapes contain information incorporated into the DOE data base. This base is used by TIC to generate multiple publications and to support information retrieval activities. Information, or data, pertinent to one bibliographic reference will be called an entry. The entries are logically composed of data elements (such as title, authors, etc.). This format supersedes a previous version, used since 1974, as described in Report TID-4581-R4. The format has been revised to permit incorporation of DOE/TIC bibliographic data encompassing the broader scope of information related to the development or use of energy resources.

  14. Test of a 2 MVA medium voltage HTS fault current limiter module made of YBCO coated conductors

    NASA Astrophysics Data System (ADS)

    Kraemer, H.-P.; Schmidt, W.; Wohlfart, M.; Neumueller, H.-W.; Otto, A.; Verebelyi, D.; Schoop, U.; Malozemoff, A. P.

    2008-02-01

    A fault current limiter module for medium voltage applications has been built and tested successfully. The module corresponds to one phase of a 3-phase limiter for the 13 kV-class distribution voltage level. The resistive type limiter consists of 15 bifilar coils wound from a total of 15 × 50 m of AMSC's 344S superconductors, a commercially available second generation YBCO tape stabilized by stainless steel laminates. The module has a rated current of 300 Arms and a rated voltage of 7.5 kV corresponding to a nominal apparent power of 2.25 MVA. The cryostat is equipped with commercial current feed-throughs and the module is operated in liquid nitrogen at atmospheric pressure. For long term operation as a closed system a commercial cryogenic refrigerator coldhead is installed. Power tests and dielectric tests of the module have been performed at the IPH Berlin (Institut "Prüffeld für elektrische Hochleistungstechnik") up to prospective currents of 28 kA. In standard power tests at voltages up to 7.8 kV and fault hold times of about 50 ms an excellent limiting performance was observed both at various prospective fault currents and at different fault starting phase angles. Within a second experimental series, an appropriate shunt reactor was connected in parallel to the limiter. The benefit of this method is that the limited current can be adjusted to the customers needs and the required amount of HTS-wire can be also appreciably reduced. The setup of the module and the test results are reported.

  15. Deployable Hexapod Using Tape-Springs

    DTIC Science & Technology

    2005-07-13

    main advantages of this concept compared to classical hyper-stable telescope structures are: - a reduced volume during launch allowing large systems...The main advantages of a deployable and active telescope structure compared to classical hyperstable telescope structures are a reduced volume...developed and manufactured by IWF TÜ Braunschweig who already applied them to motorised applications. The steel tape-spring can be rolled in the coiling

  16. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  17. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  18. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  19. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2017-04-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  20. Multifunctional Carbon Fibre Tapes for Automotive Composites

    NASA Astrophysics Data System (ADS)

    Koncherry, V.; Potluri, P.; Fernando, A.

    2016-11-01

    Cabon fibre composites are used where mechanical performance such as strength, stiffness and impact properties at low density is a critical parameter for engineering applications. Carbon fibre flat tape is one material which is traditionally used to manufacture three-dimensional composites in this area. Modifying the carbon fibre tape to incorporate other functions such as stealth, electromagnetic interference, shielding, de-icing, self-repair, energy storage, allows us to create multi-functional carbon fibre tape. Researchers have been developing such material and the technology for their manufacture in order to produce multifunctional carbon fibre based components more economically and efficiently. This paper presents the manufacturing process of a metallised carbon fibre material for a chopped fibre preforming process that uses electromagnets for preforming instead of traditional suction airflow fibre deposition. In addition, the paper further presents mechanical and magneto-static modelling that is carried out to investigate the bending properties of the material produced and its suitability for creating 3D preforms.

  1. Current Distribution in Wide YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Carrera, M.; Granados, X.; Amorós, J.; Puig, T.; Obradors, X.

    The need of a better mechanical behaviour and the stabilization of coated conductors for applications, as Magnets, cables or Fault Current Limiters, has motivated the lamination of tapes with stainless steel or copper alloys, increasing so the elastic modulus of the conductors and their mechanical performance. Some of the stainless steels used are magnetic, thus introducing some perturbations of the current flow when energizing the conductor. In order to detect these possible perturbations, the magnetic self field in the surface of the tape has been explored by Hall mapping technique at several current loads in a monotonically driven cyclic sequence. By increasing current steps when loading up, crossing the critical field threshold, and decreasing down to remanent state. Deviation from the expected magnetic map has been observed. In this work, we will report on the resulting measurements, and the current flow is calculated by solving the inverse problem for a 12 mm wide stainless steel reinforced Coated Conductor tape. We discuss on the likely origin of the observed perturbations.

  2. The Effect of Magnetic Field on HTS Leads What Happens when thePower Fails at RAL?

    SciTech Connect

    Green, Michael A.

    2007-02-14

    The key to being able to operate the MICE superconducting solenoids on small coolers is the use of high temperature superconducting (HTS) leads between the first stage of the cooler and the magnet, which operates at around 4.2 K. Because MICE magnets are not shielded, all of the MICE magnets have a stray magnetic field in the region where the coolers and the HTS leads are located. The behavior of the HTS leads in a magnetic field depends strongly on the HTS material used for the leads and the temperature of the cooler first stage temperature. The HTS leads can be specified to operate at the maximum current for the magnet. This report shows how the HTS leads can be specified for use the MICE magnets. MICE magnets take from 1.3 hours (the tracker solenoids) to 3.7 hours (the coupling magnet) to charge to the highest projected operating currents. If the power fails, the cooler and the upper ends of the HTS leads warm up. The question is how one can discharge the magnet to protect the HTS leads without quenching the MICE magnets. This report describes a method that one can use to protect the HTS leads in the event of a power failure at the Rutherford Appleton Laboratory (RAL).

  3. Anisotropic shrinkage characteristics of tape cast alumina

    NASA Astrophysics Data System (ADS)

    Patwardhan, Jaideep Suresh

    Dimensional control during sintering is a major issue in ceramics processing to avoid high post-sintering costs associated with machining of the fired ceramic part to desired tolerances and dimensions. Ceramic forming processes such as tape casting, injection molding, and extrusion involve shear of anisotropic particles resulting in preferential alignment of the particles in the green body. This preferential alignment causes directionality in mechanical, electrical, optical, and magnetic properties and most importantly warpage or distortion during sintering. A large effort has been devoted to synthesizing ceramic green bodies with minimal density gradients and uniform packing and modeling the sintering behavior evolution but little effort has been devoted to characterizing orientation of particles and the effect of preferential alignment on sintering shrinkage anisotropy. A systematic study was initiated to study the effect of processing variables such as shear rate, solids loading, temperature, and binder content on aqueous tape cast alumina. Three different alumina systems: A16-SG, Baikowski RC-UFX DBM and RC-LS DBM were investigated. Aqueous tapes of high solids loading alumina (56 vol. %) were tape cast at various speeds and thicknesses and assuming plane Couette flow a shear rate regime of 21--270 s-1 was investigated. Higher shear rates and high solids loading resulted in higher in-plane anisotropy whereas the anisotropy in the thickness direction was higher for low solids loading systems. The anisotropy was found to be fairly constant above a certain critical shear rate (˜100 s-1) irrespective of the temperature and the solids loading and this correlated with the viscosity-shear rate relationship of the cast slips. The higher shrinkage anisotropy in the thickness direction for the low solids loading systems (35 and 45 vol. %) was attributed to the higher amount of organics in the slip required to sustain the suitable viscosity for tape casting and

  4. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  5. Electrical performance analysis of HTS synchronous motor based on 3D FEM

    NASA Astrophysics Data System (ADS)

    Baik, S. K.; Kwon, Y. K.; Kim, H. M.; Lee, J. D.; Kim, Y. C.; Park, G. S.

    2010-11-01

    A 1-MW class superconducting motor with High-Temperature Superconducting (HTS) field coil is analyzed and tested. This machine is a prototype to make sure applicability aimed at generator and industrial motor applications such as blowers, pumps and compressors installed in large plants. This machine has the HTS field coil made of Bi-2223 HTS wire and the conventional copper armature (stator) coils cooled by water. The 1-MW class HTS motor is analyzed by 3D electromagnetic Finite Element Method (FEM) to get magnetic field distribution, self and mutual inductance, and so forth. Especially excitation voltage (Back EMF) is estimated by using the mutual inductance between armature and field coils and compared with experimental result. Open and short circuit tests were conducted in generator mode while a 1.1-MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests and also compared with the analysis results from FEM.

  6. Performance test of a 1 MW class HTS synchronous motor for industrial application

    NASA Astrophysics Data System (ADS)

    Kwon, Y. K.; Kim, H. M.; Baik, S. K.; Lee, E. Y.; Lee, J. D.; Kim, Y. C.; Lee, S. H.; Hong, J. P.; Jo, Y. S.; Ryu, K. S.

    2008-09-01

    This paper deals with development activities of high temperature superconducting (HTS) synchronous motor at DOOSAN heavy industry and Korea Electrotechnology Research Institute (KERI) in Korea, and is sponsored by DAPAS program which is supported by Korean government. The final aim of the project is realization of HTS motor in the field of industry such as large driving pumps, fans and compressors for utility and industrial environments. At present time, 1 MW HTS motor is developed for the purpose to fully represent the design and manufacturing issues for the larger capacity machine. The number of pole and rotating speed of machine are 2 pole and 3600 rpm. The HTS field coil of the developed motor is cooled by way of neon thermosyphon mechanism and the stator coil is cooled by water through hollow copper conductor. This paper describes status of 1 MW HTS motor development, such as design, fabrication and performance test results, which was conducted at steady state in generator mode and motor mode.

  7. AC HTS Transmission Cable for Integration into the Future EHV Grid of the Netherlands

    NASA Astrophysics Data System (ADS)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Aanhaanen, G.; Melnik, I.; Geschiere, A.

    Due to increasing power demand, the electricity grid of the Netherlands is changing. The future grid must be capable to transmit all the connected power. Power generation will be more decentralized like for instance wind parks connected to the grid. Furthermore, future large scale production units are expected to be installed near coastal regions. This creates some potential grid issues, such as: large power amounts to be transmitted to consumers from west to east and grid stability. High temperature superconductors (HTS) can help solving these grid problems. Advantages to integrate HTS components at Extra High Voltage (EHV) and High Voltage (HV) levels are numerous: more power with less losses and less emissions, intrinsic fault current limiting capability, better control of power flow, reduced footprint, etc. Today's main obstacle is the relatively high price of HTS. Nevertheless, as the price goes down, initial market penetration for several HTS components is expected by year 2015 (e.g.: cables, fault current limiters). In this paper we present a design of intrinsically compensated EHV HTS cable for future grid integration. Discussed are the parameters of such cable providing an optimal power transmission in the future network.

  8. Race-track coils for a 3 MW HTS ship motor

    NASA Astrophysics Data System (ADS)

    Ueno, E.; Kato, T.; Hayashi, K.

    2014-09-01

    Since the discovery of high-temperature superconductivity (HTS), Sumitomo Electric has been developing silver-sheathed Bi2223 superconducting wire and products. Ship propulsion motors are one of the most promising applications of HTS. Sumitomo Electric Industries, Ltd. (SEI) has recently manufactured 24 large racetrack coils, using 70 km long DI-BSCCO wires, for use in a 3 MW HTS motor developed by Kawasaki Heavy Industries, Ltd. (KHI). The 3 MW HTS motor, using our newly developed racetrack coils, has successfully passed the loading test. It is particularly important that the HTS field coils used in ship propulsion motors can withstand the expansive forces repeatedly applied to them. As racetrack type coils have straight sections, the support mechanism they require to withstand expansive forces is very different from that of circular coils. Therefore, we ran tests and obtained the basic data to evaluate the 20-year durability of racetrack coils against the repeatedly applied expansive forces expected in domestic ship propulsion motors.

  9. Design considerations and experimental results for MRI systems using HTS magnets

    NASA Astrophysics Data System (ADS)

    Parkinson, Ben

    2017-01-01

    An increasing number of magnetic resonance imaging (MRI) systems using high temperature superconductors (HTS) magnets have been designed and constructed, with detailed results of their performance now available. Features of REBCO and BSCCO conductors are described as they pertain to use in high homogeneity magnets, with emphasis placed on the practical use of these conductors in magnets. Methods of coil winding are discussed, in particular the differences between pancake and layer winding techniques. Design considerations for HTS magnets are presented in light of the difficulties presented by quench in these magnets, but also in terms of the features of HTS magnets afforded by their high operating temperatures, namely robust cryogen free operation and the potential to use unshielded gradient coils. Drawing on two example MRI systems, namely a 3 T BSCCO brain imaging magnet developed in Japan and a 1.5 T REBCO orthopaedic imaging system developed in New Zealand, the report details real-world stability and homogeneity of HTS-MRI systems, in particular with regards to the screening current effects observed in these systems. It is concluded that, apart from conductor cost, there are currently no technical obstacles to use of HTS-MRI systems.

  10. Use of in Vitro HTS-Derived Concentration-Response Data as ...

    EPA Pesticide Factsheets

    Background: Quantitative high-throughput screening (qHTS) assays are increasingly being employed to inform chemical hazard identification. Hundreds of chemicals have been tested in dozens of cell lines across extensive concentration ranges by the National Toxicology Program in collaboration with the NIH Chemical Genomics Center. Objectives: To test a hypothesis that dose-response data points of the qHTS assays can serve as biological descriptors of assayed chemicals and, when combined with conventional chemical descriptors, may improve the accuracy of Quantitative Structure-Activity Relationship (QSAR) models applied to prediction of in vivo toxicity endpoints. Methods and Results: The cell viability qHTS concentration-response data for 1,408 substances assayed in 13 cell lines were obtained from PubChem; for a subset of these compounds rodent acute toxicity LD50 data were also available. The classification k Nearest Neighbor and Random Forest QSAR methods were employed for modeling LD50 data using either chemical descriptors alone (conventional models) or in combination with biological descriptors derived from the concentration-response qHTS data (hybrid models). Critical to our approach was the use of a novel noise-filtering algorithm to treat qHTS data. We show that both the external classification accuracy and coverage (i.e., fraction of compounds in the external set that fall within the applicability domain) of the hybrid QSAR models was superior to convent

  11. Integration of HTS Cables in the Future Grid of the Netherlands

    NASA Astrophysics Data System (ADS)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Aanhaanen, G.; Melnik, I.; Geschiere, A.

    Due to increasing power demand, the electricity grid of the Netherlands is changing. The future transmission grid will obtain electrical power generated by decentralized renewable sources, together with large scale generation units located at the coastal region. In this way electrical power has to be distributed and transmitted over longer distances from generation to end user. Potential grid issues like: amount of distributed power, grid stability and electrical loss dissipation merit particular attention. High temperature superconductors (HTS) can play an important role in solving these grid problems. Advantages to integrate HTS components at transmission voltages are numerous: more transmittable power together with less emissions, intrinsic fault current limiting capability, lower ac loss, better control of power flow, reduced footprint, less magnetic field emissions, etc. The main obstacle at present is the relatively high price of HTS conductor. However as the price goes down, initial market penetration of several HTS components (e.g.: cables, fault current limiters) is expected by year 2015. In the full paper we present selected ways to integrate EHV AC HTS cables depending on a particular future grid scenario in the Netherlands.

  12. Status and Progress of a Fault Current Limiting Hts Cable to BE Installed in the con EDISON Grid

    NASA Astrophysics Data System (ADS)

    Maguire, J.; Folts, D.; Yuan, J.; Henderson, N.; Lindsay, D.; Knoll, D.; Rey, C.; Duckworth, R.; Gouge, M.; Wolff, Z.; Kurtz, S.

    2010-04-01

    In the last decade, significant advances in the performance of second generation (2G) high temperature superconducting wire have made it suitable for commercially viable applications such as electric power cables and fault current limiters. Currently, the U.S. Department of Homeland Security is co-funding the design, development and demonstration of an inherently fault current limiting HTS cable under the Hydra project with American Superconductor and Consolidated Edison. The cable will be approximately 300 m long and is being designed to carry 96 MVA at a distribution level voltage of 13.8 kV. The underground cable will be installed and energized in New York City. The project is led by American Superconductor teamed with Con Edison, Ultera (Southwire and nkt cables joint venture), and Air Liquide. This paper describes the general goals, design criteria, status and progress of the project. Fault current limiting has already been demonstrated in 3 m prototype cables, and test results on a 25 m three-phase cable will be presented. An overview of the concept of a fault current limiting cable and the system advantages of this unique type of cable will be described.

  13. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    PubMed Central

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  14. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  15. Applicability of DNA analysis on adhesive tape in forensic casework.

    PubMed

    Zech, Wolf-Dieter; Malik, Naseem; Thali, Michael

    2012-07-01

    Adhesive tape is commonly used in crimes and is often the subject of forensic evaluation. DNA analysis of adhesive tape can provide DNA profiles of suspects. The object of this study was to evaluate the applicability of DNA analysis on adhesive tape samples in forensic casework. We retrospectively reviewed all cases involving adhesive tape or similar items received by our institute for DNA analysis during the past 11 years. From 100 forensic cases reviewed, 150 adhesive tape samples were examined. A total of 98 DNA profiles were obtained from these samples. Sixty-two of the profiles provided feasible case-relevant information. In conclusion, DNA profiling of adhesive tape samples can be useful in a variety of forensic cases.

  16. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  17. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  18. Kinetics of the humid aging of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Bertram, H. N.; Cuddihy, E. F.

    1982-01-01

    The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

  19. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  20. Functional cell-based uHTS in chemical genomic drug discovery.

    PubMed

    Croston, Glenn E

    2002-03-01

    The availability of genomic information significantly increases the number of potential targets available for drug discovery, although the function of many targets and their relationship to disease is unknown. In a chemical genomic research approach, ultra-high throughput screening (uHTS) of genomic targets takes place early in the drug discovery process, before target validation. Target-selective modulators then provide drug leads and pharmacological research tools to validate target function. Effective implementation of a chemical genomic strategy requires assays that can perform uHTS for large numbers of genomic targets. Cell-based functional assays are capable of the uHTS throughput required for chemical genomic research, and their functional nature provides distinct advantages over ligand-binding assays in the identification of target-selective modulators.

  1. The Role of HTS in Drug Discovery at the University of Michigan

    PubMed Central

    Larsen, Martha J.; Larsen, Scott D.; Fribley, Andrew; Grembecka, Jolanta; Homan, Kristoff; Mapp, Anna; Haak, Andrew; Nikolovska-Coleska, Zaneta; Stuckey, Jeanne A.; Sun, Duxin

    2014-01-01

    High throughput screening (HTS) is an integral part of a highly collaborative approach to drug discovery at the University of Michigan. The HTS lab is one of four core centers that provide services to identify, produce, screen and follow-up on biomedical targets for faculty. Key features of this system are: protein cloning and purification, protein crystallography, small molecule and siRNA HTS, medicinal chemistry and pharmacokinetics. Therapeutic areas that have been targeted include anti-bacterial, metabolic, neurodegenerative, cardiovascular, anti-cancer and anti-viral. The centers work in a coordinated, interactive environment to affordably provide academic investigators with the technology, informatics and expertise necessary for successful drug discovery. This review provides an overview of these centers at the University of Michigan, along with case examples of successful collaborations with faculty. PMID:24409957

  2. Cancer and virus leads by HTS, chemical design and SEA data mining.

    PubMed

    Thepchatri, Pahk; Min, Jaeki; Ganesh, Thota; Du, Yuhong; Lewis, Iestyn; Kurtkaya, Serdar; Prussia, Andrew; Li, Lian; Sneed, Blossom; Plemper, Richard K; Fu, Haian; Liotta, Dennis C; Snyder, James P; Dingledine, Raymond; Sun, Aiming

    2009-01-01

    A variety of medicinal chemistry approaches can be used for the identification of hits, generation of leads and to accelerate the development of drug candidates. The Emory Chemical and Biology Discovery Center (ECBDC) has been an active participant in the NIH's high-throughput screening (HTS) endeavor to identify potent small molecule probes for poorly studied proteins. Several of Emory's projects relate to cancer or virus infection. We have chosen three successful examples including discovery of potent measles virus RNA-dependent RNA polymerase inhibitors, development of Heat Shock Protein 90 (Hsp90) blockers and identification of angiogenesis inhibitors using transgenic Zebrafish as a HTS model. In parallel with HTS, a unique component of the Emory virtual screening (VS) effort, namely, substructure enrichment analysis (SEA) program has been utilized in several cases.

  3. Cycle Design of Reverse Brayton Cryocooler for HTS Cable Cooling Using Exergy Analysis

    NASA Astrophysics Data System (ADS)

    Gupta, Sudeep Kumar; Ghosh, Parthasarathi

    2017-02-01

    The reliability and price of cryogenic refrigeration play an important role in the successful commercialization of High Temperature Superconducting (HTS) cables. For cooling HTS cable, sub-cooled liquid nitrogen (LN2) circulation system is used. One of the options to maintain LN2 in its sub-cooled state is by providing refrigeration with the help of Reverse Brayton Cryo-cooler (RBC). The refrigeration requirement is 10 kW for continuously sub-cooling LN2 from 72 K to 65 K for cooling 1 km length of HTS cable [1]. In this paper, a parametric evaluation of RBC for sub-cooling LN2 has been performed using helium as a process fluid. Exergy approach has been adopted for this analysis. A commercial process simulator, Aspen HYSYS® V8.6 has been used for this purpose. The critical components have been identified and their exergy destruction and exergy efficiency have been obtained for a given heat load condition.

  4. Reliability Test of a 1-kW Pulse Tube Cryocooler for Hts Cable Application

    NASA Astrophysics Data System (ADS)

    Chen, R.-L.; Henzler, G. W.; Royal, J. H.; Billingham, J. F.

    2010-04-01

    The recent progress of a large Stirling-type pulse tube cryocooler is reported based on 24/7 operation since August 2008 in a high temperature superconducting (HTS) cable application at American Electric Power's (AEP) Bixby Road substation in Columbus, OH. The 20-kW pressure wave generator (PWG) has been upgraded to a second generation design. The in-line configured pulse tube coldhead, rated at 1 kW at 77 K, was developed by Praxair. The objective of the continued testing at the HTS cable demonstration facility is to accumulate cryocooler operating hours and demonstrate system reliability. The cryocooler uses a parallel flow from the main vacuum subcooling refrigerator then both flows are supplied to the HTS cable inlet. The cryocooler operation has shown consistent results with satisfactory cooling performance. The field demonstrated thermodynamic efficiency is 15% of Carnot at 72 K.

  5. Cancer and Virus Leads by HTS, Chemical Design and SEA Data Mining

    PubMed Central

    Thepchatri, Pahk; Min, Jaeki; Ganesh, Thota; Du, Yuhong; Lewis, Iestyn; Kurtkaya, Serdar; Prussia, Andrew; Li, Lian; Plemper, Richard K.; Fu, Haian; Liotta, Dennis C.; Snyder, James P.; Dingledine, Raymond; Sun, Aiming

    2015-01-01

    A variety of medicinal chemistry approaches can be used for the identification of hits, generation of leads and to accelerate the development of drug candidates. The Emory Chemical and Biology Discovery Center (ECBDC) has been an active participant in the NIH’s high-throughput screening (HTS) endeavor to identify potent small molecule probes for poorly studied proteins. Several of Emory’s projects relate to cancer or virus infection. We have chosen three successful examples including discovery of potent measles virus RNA-dependent RNA polymerase inhibitors, development of Heat Shock Protein 90 (Hsp90) blockers and identification of angiogenesis inhibitors using transgenic Zebrafish as a HTS model. In parallel with HTS, a unique component of the Emory virtual screening (VS) effort, namely, substructure enrichment analysis (SEA) program has been utilized in several cases. PMID:19807668

  6. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  7. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  8. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  9. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 1 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 1 through 4. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002139469), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). The primary activity of flight day 1 is the launch of Space Shuttle Endeavour. The crew is seen before the launch at a meal and suit-up, and some pre-flight procedures are shown. Perrin holds a sign with a personalized message. The astronauts communicate with Mission Control extensively after launch, and an inside view of the shuttle cabin is shown. The replays of the launch include close-ups of the nozzles at liftoff, and the fall of the solid rocket boosters and the external fuel tank. Flight day 2 shows footage of mainland Asia at night, and daytime views of the eastern United States and Lake Michigan. Flight day three shows the Endeavour orbiter approaching and docking with the ISS. After the night docking, the crews exchange greetings, and a view of the Nile river and Egypt at night is shown. On flight day 4, the MPLM (Multi-Purpose Logistics Module) Leonardo was temporarily transferred from Endeavour's payload bay to the ISS.

  10. Affine transformations from aerial photos to computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Peet, F. G.; Mack, A. R.; Crosson, L. S.

    1974-01-01

    During the development of a project to estimate wheat production, it became necessary to pull data, corresponding to particular fields in a test site, off an ERTS computer compatible tape. Aerial photographs and topographic maps were on hand for the test site. A method was devised, using an affine transformation, to relate the aerial photographs or topographic maps to the tapes. One can thereby access data on the tape corresponding to regions covered by only a few pixels. The theory can be used for the registration of two tapes for the same area and for the geometric correction of images.

  11. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  12. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary; Brosha, Eric L.; Garzon, Fernando H.

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  13. The Dynamic Characteristics on the Wall Traveling of the HTS Bulk Superconducting Actuator

    NASA Astrophysics Data System (ADS)

    Sawae, M.; Kim, S. B.; Ozasa, S.; Nakano, H.; Kobayashi, H.

    The electric device applications of a high temperature superconducting (HTS) bulk having stable levitation and suspension properties due to their strong flux pinning force have been proposed and developed. We have been investigating the three-dimensional (3-D) superconducting actuator using HTS bulk to develop the transportation device with non-contact and moves in free space. It is expected that our proposed 3-D superconducting actuator to be useful as a transporter used in clean room which manufactures the silicon wafer where dislikes mechanical contact and dust. Proposed the actuator consists of a field-cooled HTS bulk for mover and two-dimensional arranged multiple electromagnets as a stator. In our previous study, the dynamic characteristics on the floor traveling of the HTS bulk mover had been studied. Therefore in this study, a system for the wall traveling was proposed to use the limited space effectively. It is expected that the wall traveling system is very useful to apply the transporter used in the tunnels which flammable gas may be produced. In this paper, the optimal angle between electromagnets located at floor and wall for moving to the wall traveling from the floor traveling was investigated experimentally. The position displacement on the rotating of the HTS bulk during the wall traveling was measured. As a result, the bulk with initial gap of 2 mm could move to the wall traveling from the floor traveling. Also, the position displacement on the height direction during the rotating of the HTS bulk was 18 mm from the initial position because of its gravity,but it was possible to rotate by changing the pattern NSNS of the trapped magnetic field in near the initial position.

  14. Performance of the BG1Luc ER TA method in a qHTS format.

    PubMed

    Ceger, Patricia; Allen, David; Huang, Ruili; Xia, Menghang; Casey, Warren

    2015-01-01

    In 2012, the BG1Luc4E2 estrogen receptor (ER) transactivation (TA) method (BG1Luc ER TA) was accepted by U.S. regulatory agencies and the Organisation for Economic Co-operation and Development to detect substances with ER agonist activity. The method is now part of the Tier 1 testing battery in the Environmental Protection Agency's Endocrine Disruptor Screening Program. The BG1Luc ER TA method uses the BG1 ovarian cell line that endogenously expresses full-length ER (α and β) and is stably transfected with a plasmid containing four estrogen responsive elements upstream of a luciferase reporter gene. To allow increased throughput and testing efficiency, the BG1Luc ER TA ("BG1 manual") method was adapted for quantitative high-throughput screening (BG1 qHTS) in the U.S. Tox21 testing program. The BG1 qHTS test method was used to test approximately 10,000 chemicals three times each, and concentration-response data (n=15) were analyzed to evaluate test method performance. The balanced accuracy of the BG1 qHTS test method (97% [32/33]) was determined by comparing results to ER TA performance standards for the BG1 manual method. Concordance between the BG1 manual and qHTS methods was 92% (57/62) when calculated for a larger set of non-reference chemicals tested in both methods. These data demonstrate that the performance of the BG1 qHTS is similar to the currently accepted BG1 manual method, thereby establishing the utility of the BG1 qHTS method for identifying ER active environmental chemicals.

  15. Numerical investigations on applicability of permanent magnet method to crack detection in HTS film

    NASA Astrophysics Data System (ADS)

    Kamitani, A.; Takayama, T.; Saitoh, A.

    2014-09-01

    The scanning permanent-magnet (PM) method was originally developed for determining the spatial distribution of the critical current density in a high-temperature superconducting (HTS) film. In the present study, its applicability to the crack detection in an HTS film is investigated numerically. To this end, a defect parameter is defined for characterizing a crack position and it is calculated along various scanning lines. The results of computations show that, only when the scanning position is near a crack, the defect parameter shows a violent change. On the basis of the behavior of the defect parameter, the method for roughly identifying a crack is also proposed.

  16. The Development and Demonstration of a 360m/10 kA HTS DC Power Cable

    NASA Astrophysics Data System (ADS)

    Xiao, Liye

    With the quick development of renewable energy, it is expected that the electric power from renewable energy would be the dominant one for the future power grid. Due to the specialty of the renewable energy, the HVDC power transmission would be very useful for the transmission of electric power from renewable energy. DC power cable made of High Tc Superconductor (HTS) would be a possible alternative for the construction of HVDC power transmission system. In this chapter, we report the development and demonstration of a 360 m/10 kA HTS DC power cable and the test results.

  17. A Study on the Body Insulators for the Bushing for HTS Devices at Cryogenic Temperature

    NASA Astrophysics Data System (ADS)

    Kim, W. J.; Shin, H. S.; Kim, S. H.

    A bushing for high temperature superconducting devices (HTS bushing) is important because of applying high voltage to the cable or the winding of the transformer. It is cooled with liquid nitrogen (LN2) and is insulated with various insulators. For the development of the HTS bushing, it is necessary to know the fundamental characteristics of various insulators at cryogenic temperature. The electrical characteristics of the breakdown were studied under AC and impulse voltages. Also, the mechanical characteristics such as tensile strength in air and LN2 were studied. It was confirmed that GFRP is excellent not only electrical characteristics but also mechanical characteristics in LN2.

  18. Improved Characteristics of Integrated HTS rf SQUID on Bicrystal SrTiO3 Substrate Resonator Covered with HTS Thin Films in Flip-Chip Geometry

    NASA Astrophysics Data System (ADS)

    Hatsukade, Yoshimi; Takemoto, Makoto; Kurosawa, Ryuichi; Uchida, Yousuke; Tanaka, Saburo

    Integrated high-temperature superconductor (HTS) radio-frequency (rf) superconducting quantum interference devices (SQUIDs) based on a bicrystal SrTiO3 substrate was investigated for application to magnetic contaminant detection. By covering a wide superconducting weak link and/or a slit of the YBa2Cu3O7-x SQUID with HTS thin films in flip-chip geometry, characteristics such as effective area and 1/f noise profile of the SQUID were successfully improved. By installing the covered SQUID in a magnetic contaminant detection system, it was demonstrated that the system can detect a tungsten ball of 15μm in diameter with a signal to noise ratio of about 2.

  19. Effects of elastic taping, non-elastic taping and static stretching on recovery after intensive eccentric exercise.

    PubMed

    Boobphachart, Disaphon; Manimmanakorn, Nuttaset; Manimmanakorn, Apiwan; Thuwakum, Worrawut; Hamlin, Michael J

    2017-01-25

    The purpose of this study was to compare the effect of elastic tape (Kinesio tape) to placebo tape or static stretching on delayed onset muscle soreness. Fifty-one untrained female healthy volunteers were randomly assigned into three groups (n = 17/group), elastic tape, placebo tape and stretching group. Muscle soreness was induced by 4 sets of 25 maximal isokinetic (60°.s(-1)) eccentric contractions of dominant quadriceps on an isokinetic dynamometer. Compared with placebo tape, the elastic tape participants had less muscle soreness at 72 h post-exercise (p = 0.01). The elastic tape also increased isometric strength at 72 h post-exercise compared with the placebo (p = 0.03) and stretching group (p = 0.02). However, there was little effect between groups for changes in thigh circumference, jumping, pressure pain threshold, rate of perceived exertion, creatine kinase activity and joint motion. Elastic taping increased muscle strength recovery and reduced muscle soreness after intensive exercise.

  20. Fabrication and characterization of Ag-clad Bi-2223 tapes.

    SciTech Connect

    Balachandran, U.

    1999-04-20

    The powder-in-tube (PIT) technique was used to fabricate multifilament (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes. Transport current properties of these tapes were enhanced by increasing the packing density of the precursor powder and improving the mechanical deformation condition. A critical current (I{sub c}) of > 35 A in long lengths (> 200 m) tapes has been achieved. In measuring the dependence of critical current density on magnetic field and temperature for the optimally processed tapes, we found a J{sub c} of > 10{sup 4} A/cm{sup 2} at 20 K in magnetic fields up to 3 T and parallel to the c-axis, which is of interest for use in refrigerator-cooled magnets. I{sub c} declined exponentially when an external field was applied perpendicular to the tape surface at 77 K. Mechanical stability was tested for tapes sheathed with pure Ag and Ag-Mg alloy. Tapes made with pure Ag sheathing can withstand a tensile stress of {approx}20 MPa with no detrimental effect on I{sub c} values. Mechanical performance was improved by using Ag-Mg alloy sheathing: values of transport critical current began to decrease at the tensile stress of {approx} 100 MPa. Transport current measurements on tapes wound on a mandrel of 3.81 cm (1.5 in.) diameter at 30{degree} to the longitudinal axis, showed a reduction of {approx} 10% in I{sub c} values for pure Ag-sheathed tapes and 5% reduction in I{sub c} values for Ag-Mg sheathed tapes, compared with the I{sub c} values of as-coiled tapes.

  1. Tape Recorders and the Commuter Student: Bypassing the Red Pen.

    ERIC Educational Resources Information Center

    Kates, Ronald

    1998-01-01

    Discusses several ways in which tape-recorded responses by the instructor to student writing can benefit commuter students. Discusses how the audio cassette responses are paired with a series of questions on the writing process and how the author shapes his tape-recorded comments. Notes student responses about the advantages of this approach. (SR)

  2. Design Your Organization's Own Slide-Tape Show

    ERIC Educational Resources Information Center

    Tilden, Scott W.

    1975-01-01

    Slide-tape shows offer a relatively inexpensive, easy-to-assemble means of informing a wide variety of groups interested in education. This article outlines a seven-step procedure to produce a coherent, professional-looking slide-tape presentation. (DS)

  3. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  4. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... COMMISSION Pressure Sensitive Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed... antidumping duty finding on pressure sensitive plastic tape from Italy would be likely to lead to continuation... Commission are contained in USITC Publication 4128 (March 2010), entitled Pressure Sensitive Plastic...

  5. Library and Reference Applications: Census Tapes and Printed Reports.

    ERIC Educational Resources Information Center

    Anders, Mary Edna

    Census tapes are not a ready reference tool and must be supported by appropriate program tapes. However, census materials provide the single, most important sources of information and measures which, properly used, provide a better understanding of our society. In utilizing census products, librarians need to fill the role of a user, as well as…

  6. A CLASSIFICATION AND RETRIEVAL SYSTEM FOR RECORDED FOREIGN LANGUAGE TAPES.

    ERIC Educational Resources Information Center

    KAY, J.B.; JAMESON, A.

    A CLASSIFICATION SYSTEM FOR FOREIGN LANGUAGE RECORDINGS, DEVISED FOR USE AT THE UNIVERSITY OF ESSEX, IS DESCRIBED IN THIS ARTICLE. CODING AND CROSS-REFERENCE SYSTEMS FOR THE VARIOUS CATEGORIES OF TAPES ARE OUTLINED, AND SPECIFIC EXAMPLES ARE INCLUDED. APPENDED IS A LIST OF TAPE REFERENCE CODES. THE SYSTEM OUTLINED IS NOT CONSIDERED IDEAL, BUT IT…

  7. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  8. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  9. Long-term operating characteristics of Japan's first in-grid HTS power cable

    NASA Astrophysics Data System (ADS)

    Nakano, Tetsutaro; Maruyama, Osamu; Honjo, Shoichi; Watanabe, Michihiko; Masuda, Takato; Hirose, Masayuki; Shimoda, Masahiro; Nakamura, Naoko; Yaguchi, Hiroharu; Machida, Akito

    2015-11-01

    Tokyo Electric Power Company, Sumitomo Electric Industries, Ltd and Mayekawa Mfg. Co., Ltd have jointly conducted the first in-grid demonstration test of a high-temperature superconducting (HTS) cable in Japan, from FY2007 to FY2013. The objective of this project is to evaluate the reliability, stability and other characteristics of the system. The cable structure used in this project is the type of three-in-one cable. As a coolant, sub-cooled liquid nitrogen flows through the gap between the corrugated cryostat and the three cable cores. This structure can realize compactness and reduce heat invasion compared with three single-core HTS cables housed in separate cryostats. The cooling system consists of six refrigerators, two circulation pumps and a reservoir tank. Each refrigerator has a cooling power of 1.0 kW at 77 K, 0.8 kW at 67 K. The number of operating refrigerators is controlled so that the coolant temperature at the cable inlet is kept to preset value. The HTS cable was connected to the live electricity grid from October 29, 2012 to December 25, 2013. In-grid operation continued for more than one year without any accidental interruption of operation or other operating issues. During this time, we studied the operating performance of the HTS cable in dependence on the sub-cooled LN2 temperature.

  10. Pathway Profiling and Tissue Modeling Using ToxCast HTS Data

    EPA Science Inventory

    High-throughput screening (HTS) and high-content screening (HCS) assays are providing data-rich studies to probe and profile the direct cellular effects of thousands of chemical compounds in commerce or potentially entering the environment. In vitro profiling may compare unknown ...

  11. Reduction of flux-creep in magnetized bulk HTS by use of permanent magnets

    NASA Astrophysics Data System (ADS)

    Parks, D.; Weinstein, R.; Davey, K.; Sawh, R.-P.; Carpenter, K.

    2017-01-01

    We report the effect of permanent magnet (PM) collars on the flux-creep rate of magnetized bulk HTS. The creep rates of single-grain, cylindrical samples are measured with attached collars activated to various fields, B PM, in the range 0 ≤ B PM ≤ B PM,max, where B PM,max is the fully saturated field of the PM. As B PM varies, the creep rate of the HTS is found to maintain its well-known form—a constant fractional loss λ, of original residual field, per decade of time. However, the magnitude of λ decreases as B PM increases. The decrease in λ is found to be linearly dependent on increasing B PM. The collar field for which flux-creep extrapolates to zero is found to be comparable to the maximum trappable field of the HTS bulk, B T,max. The properties of the dependence of λ on the HTS peak field, B T,max, the PM field, B PM, and the creep rate λ 0 with B PM = 0 permit the reduced creep rate in these experiments to be predicted by a universal equation.

  12. Predictive Signatures of Developmental Toxicity Modeled with HTS Data from ToxCast™ Bioactivity Profiles

    EPA Science Inventory

    The EPA ToxCast™ research program uses a high-throughput screening (HTS) approach for predicting the toxicity of large numbers of chemicals. Phase-I contains 309 well-characterized chemicals which are mostly pesticides tested in over 600 assays of different molecular targets, cel...

  13. Nanomaterial (NM) bioactivity profiling by ToxCast high-throughput screening (HTS)

    EPA Science Inventory

    Rapidly increasing numbers of new NMs and their uses demand efficient tests of NM bioactivity for safety assessment. The EPA’s ToxCast program uses HTS assays to prioritize for targeted testing, identify biological pathways affected, and aid in linking NM properties and potential...

  14. Thermal Insulation Performance of Flexible Piping for Use in HTS Power Cables

    NASA Technical Reports Server (NTRS)

    Fesmire, James E.; Augustynowicz, S. D.; Demko, J. A.; Thompson, Karen (Technical Monitor)

    2001-01-01

    High-temperature superconducting (HTS) cables that typically operate at temperatures below 80 K are being developed for power transmission. The practical application of HTS power cables will require the use of flexible piping to contain the cable and the liquid nitrogen coolant. A study of thermal performance of multilayer insulation (MLI) was conducted in geometries representing both rigid and flexible piping. This experimental study performed at the Cryogenics Test Laboratory of NASA Kennedy Space Center provides a framework for the development of cost-effective, efficient thermal insulation systems that will support these long-distance flexible lines containing HTS power cables. The overall thermal performance of the insulation system for a rigid configuration and for a flexible configuration, simulating a flexible HTS power cable, was determined by the steady-state liquid nitrogen boiloff method under the full range of vacuum levels. Two different cylindrically rolled material systems were tested: a standard MLI and a layered composite insulation (LCI). Comparisons of ideal MLI, MLI on rigid piping, and MLI between flexible piping are presented.

  15. Electrical parameter evaluation of a 1 MW HTS motor via analysis and experiments

    NASA Astrophysics Data System (ADS)

    Baik, S. K.; Kwon, Y. K.; Kim, H. M.; Kim, S. H.; Lee, J. D.; Kim, Y. C.; Park, H. J.; Kwon, W. S.; Park, G. S.

    2009-06-01

    A 1 MW class HTS (high-temperature superconducting) synchronous motor has been developed. Design concerns of the developed motor are focused on smaller machine size and higher efficiency than conventional motors or generators with the same rating simultaneously reducing expensive Bi-2223 HTS wire which is used for superconducting field coil carrying the operating current around 30 K (-243 °C). Influence of an important parameter, synchronous reactance, has been analyzed on the machine performances such as voltage variation and output power during motor and generator operation. The developed motor was also analyzed by three-dimensional electromagnetic FEM (finite element method) to get magnetic field distribution, inductance, electromagnetic stress and so forth. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of Neon thermosiphon mechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results which were obtained at steady state in generator and motor mode of our HTS machine.

  16. Assessment of High Temperature Superconducting (HTS) electric motors for rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Doernbach, Jay

    1990-01-01

    The successful development of high temperature superconductors (HTS) could have a major impact on future aeronautical propulsion and aeronautical flight vehicle systems. Applications of high temperature superconductors have been envisioned for several classes of aeronautical systems, including subsonic and supersonic transports, hypersonic aircraft, V/STOL aircraft, rotorcraft and solar powered aircraft. The potential of HTS electric motors and generators for providing primary shaft power for rotorcraft propulsion is examined. Three different sized production helicopters were investigated; namely, the Bell Jet Ranger, the Sikorsky Black Hawk and the Sikorsky Super Stallion. These rotorcraft have nominal horsepower ratings of 500, 3600, and 13400 respectively. Preliminary results indicated that an all-electric HTS drive system produces an improvement in rotorcraft Takeoff Gross Weight (TOGW) for those rotorcraft with power ratings above 2000 horsepower. The predicted TOGW improvements are up to 9 percent for the medium-sized Sikorsky Black Hawk and up to 20 percent for the large-sized Sikorsky Super Stallion. The small-sized Bell Jet Ranger, however, experienced a penalty in TOGW with the all-electric HTS drive system.

  17. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  18. The Adipocyte-Inducible Secreted Phospholipases PLA2G5 and PLA2G2E Play Distinct Roles in Obesity

    PubMed Central

    Sato, Hiroyasu; Taketomi, Yoshitaka; Ushida, Ayako; Isogai, Yuki; Kojima, Takumi; Hirabayashi, Tetsuya; Miki, Yoshimi; Yamamoto, Kei; Nishito, Yasumasa; Kobayashi, Tetsuyuki; Ikeda, Kazutaka; Taguchi, Ryo; Hara, Shuntaro; Ida, Satoshi; Miyamoto, Yuji; Watanabe, Masayuki; Baba, Hideo; Miyata, Keishi; Oike, Yuichi; Gelb, Michael H.; Murakami, Makoto

    2014-01-01

    Summary Metabolic disorders including obesity and insulin resistance have their basis in dysregulated lipid metabolism and low-grade inflammation. In a microarray search of unique lipase-related genes whose expressions are associated with obesity, we found that two secreted phospholipase A2s (sPLA2s), PLA2G5 and PLA2G2E, were robustly induced in adipocytes of obese mice. Analyses of Pla2g5−/− and Pla2g2e−/− mice revealed distinct and previously unrecognized roles of these sPLA2s in diet-induced obesity. PLA2G5 hydrolyzed phosphatidylcholine in fat-overladen low-density lipoprotein to release unsaturated fatty acids, which prevented palmitate-induced M1 macrophage polarization. As such, PLA2G5 tipped the immune balance toward an M2 state, thereby counteracting adipose tissue inflammation, insulin resistance, hyperlipidemia and obesiy. PLA2G2E altered minor lipoprotein phospholipids, phosphatidylserine and phosphatidylethanolamine, and moderately facilitated lipid accumulation in adipose tissue and liver. Collectively, the identification of “metabolic sPLA2s” adds this gene family to a growing list of lipolytic enzymes that act as metabolic coordinators. PMID:24910243

  19. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  20. BACKUP -- Recovering from incremental tape backups

    NASA Astrophysics Data System (ADS)

    Allan, P. M.

    The importance of making regular backups of your disks in well known, but it can be very frustrating to have a head crash and then discover that you cannot recover from your backups because the manuals do not tell you what to do. The DEC documentation covers most possibilities, but not the case where a removable pack is copied to a new pack, the new pack is then used as the current pack, and incremental backups to tape are then made. This situation is a fairly common one when you have two or more removable disk drives. This note covers backup and recovery in general terms, and details exactly what to do in the above mentioned case.

  1. An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

    NASA Astrophysics Data System (ADS)

    Brown, G. V.; Dirusso, E.; Provenza, A. J.

    1995-08-01

    A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

  2. A miniaturized HTS microwave receiver front-end subsystem for radar and communication applications

    NASA Astrophysics Data System (ADS)

    Bian, Yongbo; Guo, Jin; Gao, Changzheng; Li, Chunguang; Li, Hong; Wang, Jia; Cui, Bin; He, Xiaofeng; Li, Chao; Li, Na; Li, Guoqiang; Zhang, Qiang; Zhang, Xueqiang; Meng, Jibao; He, Yusheng

    2010-08-01

    This paper presents a miniaturized high performance high temperature superconducting (HTS) microwave receiver front-end subsystem, which uses a mini stirling cryocooler to cool a high selective HTS filter and a low noise amplifier (LNA). The HTS filter was miniaturized by using specially designed compact resonators and fabricating with double-sided YBCO films on LAO substrate which has a relatively high permittivity. The LNA was specially designed to work at cryogenic temperature with noise figure of 0.27 dB at 71 K. The mini cryocooler, which is widely used in infrared detectors, has a smaller size (60 mm × 80 mm × 100 mm) and a lighter weight (340 g) than the stirling cryocoolers commonly used in other HTS filter subsystem. The whole front-end subsystem, including a HTS filter, a LNA, a cryocooler and the vacuum chamber, has a size of only φ120 mm × 175 mm and a weight of only 3.3 kg. The microwave devices inside the subsystem are working at 71.8 K with a consumed cooling power of 0.325 W. The center frequency of this subsystem is 925.2 MHz and the bandwidth is 2.7 MHz (which is a fractional bandwidth of 0.2%), with the gain of 19.75 dB at center frequency and the return loss better than -18.11 dB in the pass band. The stop band rejection is more than 60 dB and the skirt slope is exceeding 120 dB MHz -1. The noise figure of this subsystem is less than 0.8 dB. This front-end subsystem can be used in radars and communication systems conveniently due to it’s compact size and light weight.

  3. An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

    NASA Technical Reports Server (NTRS)

    Brown, G. V.; Dirusso, E.; Provenza, A. J.

    1995-01-01

    A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

  4. PLA2G16 promotes osteosarcoma metastasis and drug resistance via the MAPK pathway.

    PubMed

    Li, Lin; Liang, Shoulei; Wasylishen, Amanda R; Zhang, Yanqin; Yang, Xueli; Zhou, Bingzheng; Shan, Luling; Han, Xiuxin; Mu, Tianyang; Wang, Guowen; Xiong, Shunbin

    2016-04-05

    The prognosis of metastatic osteosarcoma is dismal and a better understanding of the mechanisms underlying disease progression is essential to improve treatment options and patient outcomes. We previously demonstrated Pla2g16 overexpression in mouse osteosarcoma contributes to metastasis phenotypes and increased expression of PLA2G16 is associated with metastasis and poor prognosis in human tumors. To further examine the mechanisms through which PLA2G16 contributes to human osteosarcoma metastasis and explore the potential of PLA2G16 as a therapeutic target in osteosarcoma, we generated a panel of human osteosarcoma cell lines expressing different levels of PLA2G16. The functional analyses of these cell lines demonstrated high levels of PLA2G16 expression increased osteosarcoma cell migration, invasion, clonogenic survival, and anchorage-independent colony formation. Importantly, this activity was dependent on the phospholipase activity of PLA2G16. Additionally, PLA2G16 overexpression decreased the sensitivity of cells to a panel of chemotherapeutic agents. Analysis of downstream pathways revealed the pro-metastasis functions of PLA2G16 were mediated through the MAPK pathway, as knockdown of PLA2G16 decreased ERK1/2 phosphorylation and pharmacological inhibition of MEK significantly repressed PLA2G16 mediated cell migration and clonogenic survival. Furthermore, PLA2G16 overexpression promoted xenograft tumor growth in vivo, and these tumors exhibit increased ERK1/2 phosphorylation. Lastly, the expression of PLA2G16 is strongly correlated with the increased ERK1/2 phosphorylation in human osteosarcoma samples, and the combined lesions are associated with reduced overall and metastasis-free survival. Collectively, these results demonstrate increased PLA2G16 expression activates the MAPK pathway to enhance osteosarcoma metastasis and may be a novel therapeutic target for these cancers.

  5. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  6. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  7. Tape extensometer sensitivity and reliability. [Climax fuel storage at NTS

    SciTech Connect

    Yow, J.L. Jr.; Wilder, D.G.

    1981-09-21

    The Spent Fuel Test-Climax is a test of retrievable storage in granite of spent nuclear reactor fuel. The rock has been instrumented to measure temperatures, stress changes, and displacements. Periodic tape extensometer readings provide test drift convergence data. Vertical and horizontal tape readings are made at five locations in each of two 3.4m x 3.4m (11 ft x 11 ft) drifts and six locations in a 4.6m x 6.2m (15 ft x 20.5 ft) drift. The sensitivity of the readings to temperature effects, errors in temperature corrections, change of steel tape, and change of operator has been examined. Calculated corrections for temperature-induced changes in distance range from 0.001 in. to 0.003 in.//sup 0/C. A tape changeout evidenced both a systematic error apparently due to slight changes in tape registration during punching and to nonidentical location of punched holes in the two tapes and a random error due to variability of reading and punching operations. These errors were corrected by making duplicate measurements for the tapes. Tape readings by the same operator have been repeatable within +-0.001 in. in the smaller drifts and +-0.002 in. in the larger. Different operators have been able to repeat readings to within +-0.004 in. (usually within +-0.002 in.) with generally consistent direction of offset between operators. Corrections of readings and review of plotted data show the tape extensometer to be a reliable instrument for tunnel convergence measurements.

  8. Adhesive Tape and Intravascular-Catheter-Associated Infections

    PubMed Central

    Redelmeier, Donald A; Livesley, Nigel J

    1999-01-01

    Adhesive tape is placed in close contact with intravascular catheters for extended periods and could theoretically contribute to local infections. We found that 74% of specimens of tape collected in one hospital were colonized by pathogenic bacteria. However, only 5% of specimens had significant growth from an inner layer obtained by discarding the outside layer from each roll. We suggest that adhesive tape is a potential source of pathogenic bacteria and that discarding the outer layer from a partially used roll might be a simple method for reducing the risk of infection to patients. PMID:10354258

  9. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  10. An HTS flux pump operated by directly driving a superconductor into flux flow region in the E- J curve

    NASA Astrophysics Data System (ADS)

    Geng, Jianzhao; Coombs, T. A.

    2016-09-01

    High-T c superconducting (HTS) flux pumps are capable of compensating the persistent current decay in HTS magnets without electrical contact. In this paper, following work on a low-T c superconducting self-switching flux pump, we propose a new HTS flux pump by directly driving a high-T c superconductor into the flux flow region in the E- J curve. The flux pump consists of a transformer which has a superconducting secondary winding shorted by an YBCO-coated conductor bridge. A high alternating current with a much higher positive peak value than the negative peak value is induced in the secondary winding. The current always drives the bridge superconductor into the flux flow region only at around its positive peak value, thus resulting in flux pumping. The proposed flux pump is much simpler than existing HTS flux pumps.

  11. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  12. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  13. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  14. Creating and Using Video Tapes for Cartographic Demonstrations.

    ERIC Educational Resources Information Center

    Andrews, Sona K.; Gersmehl, Philip J.

    1986-01-01

    Offers nine suggestions for video tape production and instructional use in a student laboratory for a cartography course. Briefly discusses costs and benefits, including more time for instructors to focus on specific techniques and individual questions. (TRS)

  15. Solar cell interconnection and packaging using tape carrier

    SciTech Connect

    Kim, N.P.; Stanbery, B.J.

    1991-06-04

    This paper describes an array of photovoltaic cells. It comprises: photovolatic cells having a ratio of mass to surface area of less than 60 milligrams/square centimeter; a dielectric tape having a carrier surface for supporting the photovoltaic cells; interconnect means including an electrical circuit for electrically interconnecting the photovoltaic cells, the interconnect means supported by the dielectric tape on the carrier surface, the electrical circuit including contact fingers; and means defining primary openings in the dielectric tape, a primary opening being associated with a contact finger and positioned such that the contact finger can be directed from below the carrier surface in the direction of the photovoltaic cells and electrically connected to a photovoltaic cell, a portion of both sides of the contact finger being substantially free of the dielectric tape. This patent also describes the array of the above claim, wherein the photovoltaic cells are tandem cells including an upper subcell and a lower subcell.

  16. 4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INTERIOR VIEW SHOWING CURRENT USE AS MAGNETIC TAPE STORAGE FACILITY; VIEW TO NORTHEAST. - Cape Canaveral Air Station, Launch Complex 17, Facility 36002, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  17. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  18. 11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM FLOOR OF DRYDOCK NO. 5. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA

  19. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR...

  20. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  1. Magnetic Imaging of Superconducting Tapes to Determine Current Flow

    NASA Astrophysics Data System (ADS)

    Mueller, Fred M.; Brown, David J.; Hawley, Marilyn E.; Brown, Geoffrey W.; Yates Coulter, J.

    2000-03-01

    We have developed a magnetic imaging system which yields quantitative information about the magnetic field near the surface of a superconducting tape while it is carrying current at liquid nitrogen temperatures. The imaging system is based on a mechanical scanner with motion coupled into a dewar and uses standard magnetoresistive read heads from computer hard disk drives as the sensor elements. We have numerically inverted the external magnetic field data from silver-coated YBCO tapes to derive the internal tape current densities. Preliminary results are consistent with the expected patterns in the tapes, obey sum rules, and exhibit time reversal symmetry. Preliminary current flow paths suggest that the current density can be non-uniform.

  2. 34. Perimeter acquisition radar building room #325, tape handler room ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Perimeter acquisition radar building room #325, tape handler room - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND

  3. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  4. 75 FR 17124 - Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of Antidumping Duty Finding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... International Trade Administration Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of... plastic tape (PSP Tape) from Italy would be likely to lead to continuation or recurrence of dumping and of... to be revoked. See Pressure Sensitive Plastic Tape from Italy: Final Results of Expedited...

  5. Stability test of conduction-cooled LTS/HTS composite coil

    NASA Astrophysics Data System (ADS)

    Cui, Ying Min; Wang, Yin Shun; Lv, Gang; Pi, Wei

    2016-06-01

    A small LTS/HTS composite coil made of NbTi/Cu and YBCO, with an inner diameter of 80 mm, an outer diameter of 88mm, a height of 50 mm, and an inductance of 5.5 μH, was designed to test its heat disturbance performance in a GM cryocooler. For comparison, a conventional LTS coil of a similar size made of NbTi/Cu wire was also tested. Transport current was applied from 50 A to 700 A at 8 K and 8.5 K, respectively. The two coils’ heat disturbance, minimum quench energy and quench propagation velocity performance were investigated and simulated. The results indicate that the LTS/HTS composite coil shows better thermal stability and is more fit for operation in conductive cryocooler systems compared to LTS coils.

  6. A method to enhance the curve negotiation performance of HTS Maglev

    NASA Astrophysics Data System (ADS)

    Che, T.; Gou, Y. F.; Deng, Z. G.; Zheng, J.; Zheng, B. T.; Chen, P.

    2015-09-01

    High temperature superconducting (HTS) Maglev has attracted more and more attention due to its special self-stable characteristic, and much work has been done to achieve its actual application, but the research about the curve negotiation is not systematic and comprehensive. In this paper, we focused on the change of the lateral displacements of the Maglev vehicle when going through curves under different velocities, and studied the change of the electromagnetic forces through experimental methods. Experimental results show that setting an appropriate initial eccentric distance (ED), which is the distance between the center of the bulk unit and the center of the permanent magnet guideway (PMG), when cooling the bulks is favorable for the Maglev system’s curve negotiation. This work will provide some available suggestions for improving the curve negotiation performance of the HTS Maglev system.

  7. Design and testing of the HTS bearing for a 10 kWh flywheel system

    NASA Astrophysics Data System (ADS)

    Day, A. C.; Strasik, M.; McCrary, K. E.; Johnson, P. E.; Gabrys, J. W.; Schindler, J. R.; Hawkins, R. A.; Carlson, D. L.; Higgins, M. D.; Hull, J. R.

    2002-05-01

    Flywheels are of interest for a wide range of energy storage applications, from support of renewable resources to distributed power applications and uninterruptible power systems (UPS) (Day et al 2000 Proc. EESAT 2000 (Orlando, FL, Sept. 2000)). The use of high-temperature superconducting (HTS) bearings for such systems has significant advantages for applications requiring large amounts of energy to be stored with low parasitic losses and with minimal system maintenance. As flywheel systems increase in size, it becomes a significant challenge to provide adequate stiffness in these bearings without exceeding the strength limits of rotating magnet assemblies. The Boeing Company is designing and building a prototype flywheel of 10 kWh total stored energy and has focused much effort on the HTS bearing system. This paper will describe the general structure of the bearing and the steps taken to optimize its magnetic and structural performance and show recent test results.

  8. Parameter identification of the complete-moving-hysteresis model for HTS steel

    SciTech Connect

    Kahler, G.R.; Della Torre, E.; Vajda, F. . Inst. for Magnetics Research)

    1994-11-01

    This paper discusses an extension to soft magnetic materials of the identification method of the CMH model which was originally introduced for medium hard magnetic materials. The proposed Preisach function for HTS steel, a soft magnetic material, is normal in the interaction field and is assumed to be lognormal in the critical field. Although the Preisach function is not symmetrical, the logarithm of the operative Preisach function is. However, the moving parameter, [alpha], can not be obtained by finding the value that removes this asymmetry because of the presence of apparent reversible magnetization and the lognormal nature of the Preisach function. All the Preisach parameters can be obtained using the major curve and the virgin curve only. For HTS steel, the squareness is 0.004, indicating a small irreversible magnetization component. The coercivity is 8.6 Oe; whereas the remanence coercivity is an order of magnitude larger, namely 123.5 Oe.

  9. Observation of the thermosiphon effect in the circulation of liquid nitrogen in HTS cable cooling system

    NASA Astrophysics Data System (ADS)

    Ivanov, Yury; Watanabe, Hirofumi; Hamabe, Makoto; Kawahara, Toshio; Sun, Jian; Yamaguchi, Satarou

    It is traditionally considered that superconducting technology is just the way that will help to overcome the energy crisis and improve the environmental safety of the electricity production. However, real achievements in this field still insufficient to build commercial long power transmission lines. In particular, cooling systems constructed using expensive coolant circulation pumps have to be improved. Our previous calculations show that the use of a thermosiphon effect may reduce both the heat load and the required coolant circulation pump power and, ideally, would completely abandon the forced circulation. Direct experimental verification of this approach has been carried out at the new 200-meter HTS DC experimental facility of the Chubu University. The thermosiphon effect was clearly observed in satisfactory agreement with theory, although the change in elevation of the cryopipe was small. Our results will be used to design an effective HTS cable cooling system based on natural circulation of the coolant.

  10. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  11. Empirical Characterization of Unconstrained Tape Spring Deployment Dynamics

    DTIC Science & Technology

    2012-03-22

    panded from simple homogeneous materials into the lighter, stiffer composites such as S-glass and carbon fiber reinforced plastic (CFRP). Allowable...stiffer composites such as S-Glass and carbon fiber reinforced plastic (CFRP). Allowable thickness, layup count and layup orienta- tion continue to be...205 GPa for Young’s Modulus, and 0.29 for Poisson’s Ratio. E ν 3.1.1.2 CFRP Tape Springs. The carbon fiber reinforced plastic (CFRP) tape springs used

  12. FGGE/SBUV tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/SBUV Level 2C data set consists of 12 9-track data tapes, each of which contains total ozone and ozone profile data for one calendar month grouped in files containing the data in a 6 hour synoptic time block. The data flow and quality checks in the production of this data set are described as well as the format of the data tapes and the accompanying shipping documents.

  13. Heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter

    NASA Astrophysics Data System (ADS)

    Sung, Hae-Jin; Go, Byeong-Soo; Jiang, Zhenan; Park, Minwon; Yu, In-Keun

    2016-11-01

    The development of an effective high-temperature superconducting (HTS) generator is currently a research focus; however, the reduction of heat loss of a large-scale HTS generator is a challenge. This study deals with a heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter. The generator module consists of an HTS rotor of the generator and an HTS flux pump exciter. The specifications of the module were described, and the detailed configuration of the module was illustrated. For the heat loss analysis of the module, the excitation loss of the flux pump exciter, eddy current loss of all of the structures in the module, radiation loss, and conduction loss of an HTS coil supporter were assessed using a 3D finite elements method program. In the case of the conduction loss, different types of the supporters were compared to find out the supporter of the lowest conduction loss in the module. The heat loss analysis results of the module were reflected in the design of the generator module and discussed in detail. The results will be applied to the design of large-scale superconducting generators for wind turbines including a cooling system.

  14. Concepts for using trapped-flux HTS in motors and generators

    NASA Astrophysics Data System (ADS)

    Hull, John R.; Strasik, Michael

    2013-01-01

    We examine the expected performance of a brushless motor/generator that uses trapped-flux (TF) bulk high-temperature superconductors (HTSs) to provide magnetomotive force, where the stator windings are used to create the TF. A key feature is the use of dysprosium (Dy) for the stator and rotor cores. We also examine methods to energize TF in HTS for generators used in pulsed-power applications.

  15. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  16. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  17. The effect of Kinesio Taping on handgrip strength

    PubMed Central

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18–30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values. PMID:25931682

  18. The effect of Kinesio Taping on handgrip strength.

    PubMed

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  19. Development of the industrial scale Ag/Bi-2223 tape

    NASA Astrophysics Data System (ADS)

    Fujikami, J.; Kaneko, T.; Ayai, N.; Kobayashi, S.; Hayashi, K.; Takei, H.; Sato, K.

    2002-10-01

    Tape shaped silver-sheathed Bi-2223 superconducting wire (Bi-2223 tape) technologies are reported. The operations of superconducting apparatus at liquid nitrogen temperature or at 20-30 K are expectable by using Bi-2223-tapes. The reduction of AC loss at 77 K is critical for power cable application, such as electric transmission cable and transformer prototypes. Thinning of the tape thickness and twisting of the tapes are the main techniques for the reduction of AC loss. For the power transformer application, coating technology is investigated to have good electrical insulation. The refrigerator-cooled magnet for industrial use is another example of the superconducting apparatus operating at 20-30 K. It is important to know the critical current density dependence on the applied magnetic field ( Jc- B dependence) for the magnet design. It was confirmed that Jc of the Bi-2223 tape, which shows Jc=30 kA/cm 2 at 77 K in self-magnetic field, exceeds 100 kA/cm 2 at 20 K, and 1 T.

  20. Longitudinal magnetization loss in twisted multifilamentary Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Amemiya, N.; Rabbers, J.-J.; Krooshoop, B. E.; ten Haken, B.; ten Kate, H.; Ayai, N.; Hayashi, K.

    2002-08-01

    Multifilamentary Bi2223 tapes are exposed to the longitudinal magnetic field as well as the transverse one in some electrical power apparatuses such as multilayer power transmission cables. Here, we define the longitudinal and transverse magnetic fields as the field components parallel and perpendicular to the tape axis, respectively. If the filament-bundle is twisted, it can couple to the AC longitudinal magnetic field to generate the longitudinal magnetization loss. Furthermore, the AC transport current flowing spirally in the twisted filament-bundle possibly influences the longitudinal magnetization. The longitudinal magnetization loss was measured in a twisted multifilamentary Bi2223 tape exposed to longitudinal magnetic field and carrying the transport current. The measured longitudinal magnetization loss in the twisted tape exposed to the longitudinal magnetic field is larger than that in another untwisted tape. Supplying the AC transport current changes the longitudinal magnetization loss in the twisted tape exposed to the AC longitudinal magnetic field. The influence of the transport current depends on the phase relation between the longitudinal magnetic field and the transport current. If their phase difference is 0°, the longitudinal magnetization loss decreases remarkably with increasing amplitude of the transport current. It means that the change in the current distribution due to the transport current results in the decrease in the power flow from the magnet power supply. But, a preliminary measurement of the transport loss shows that the total loss increases with increasing transport current.

  1. Tape blisters after hip surgery: can they be eliminated completely?

    PubMed

    Koval, Kenneth J; Egol, Kenneth A; Hiebert, Rudi; Spratt, Kevin F

    2007-05-01

    It was recently reported that use of a perforated, stretchable cloth tape instead of silk tape reduced the incidenc of postoperative blisters around the hip from 41% to 10%. The present prospective randomized study was conducted to determine whether use of spica bandage (vs the cloth tape) could further reduce or eliminate the incidence of these blisters. Patients were randomized to 2 treatmen groups: perforated, stretchable cloth tape (Hypafix; Smit & Nephew, Memphis, Tenn) and elastic spica bandage tha was started at the lower thigh and was extended aroun the hip and abdomen. After surgery, cloth tape or spic bandage was applied over the postoperative dressing, with care taken not to produce skin tension. At the first dressing change, presence or absence of blisters was recorded, along with their number, size, location, and type. All subsequent dressing changes were done much as they wer at surgery, using the assigned type of dressing. Presence or absence of blisters was recorded at each subsequent dressing change. Two hundred ninety-four patients (300 hips) were enrolled. Twenty-two (7.33%) of the 300 hips developed a blister. Risk for developing a blister was 10% with the cloth tape versus 4.67% with the elastic spica bandage (P < .09). Surgery type (arthroplasty vs open reduction and internal fixation [ORIF], P < .03) and surgery duration (P < .05) had more of an effect on postoperative blister formation than dressing type.

  2. Buffer layers on metal alloy substrates for superconducting tapes

    DOEpatents

    Jia, Quanxi; Foltyn, Stephen R.; Arendt, Paul N.; Groves, James R.

    2004-10-05

    An article including a substrate, at least one intermediate layer upon the surface of the substrate, a layer of an oriented cubic oxide material having a rock-salt-like structure upon the at least one intermediate layer, and a layer of a SrRuO.sub.3 buffer material upon the oriented cubic oxide material layer is provided together with additional layers such as a HTS top-layer of YBCO directly upon the layer of a SrRuO.sub.3 buffer material layer. With a HTS top-layer of YBCO upon at least one layer of the SrRuO.sub.3 buffer material in such an article, J.sub.c 's of up to 1.3.times.10.sup.6 A/cm.sup.2 have been demonstrated with projected I.sub.c 's of over 200 Amperes across a sample 1 cm wide.

  3. Passive radiative cooling of a HTS coil for attitude orbit control in micro-spacecraft

    NASA Astrophysics Data System (ADS)

    Inamori, Takaya; Ozaki, Naoya; Saisutjarit, Phongsatorn; Ohsaki, Hiroyuki

    2015-02-01

    This paper proposes a novel radiative cooling system for a high temperature superconducting (HTS) coil for an attitude orbit control system in nano- and micro-spacecraft missions. These days, nano-spacecraft (1-10 kg) and micro-spacecraft (10-100 kg) provide space access to a broader range of spacecraft developers and attract interest as space development applications. In planetary and high earth orbits, most previous standard-size spacecraft used thrusters for their attitude and orbit control, which are not available for nano- and micro-spacecraft missions because of the strict power consumption, space, and weight constraints. This paper considers orbit and attitude control methods that use a superconducting coil, which interacts with on-orbit space plasmas and creates a propulsion force. Because these spacecraft cannot use an active cooling system for the superconducting coil because of their mass and power consumption constraints, this paper proposes the utilization of a passive radiative cooling system, in which the superconducting coil is thermally connected to the 3 K cosmic background radiation of deep space, insulated from the heat generation using magnetic holders, and shielded from the sun. With this proposed cooling system, the HTS coil is cooled to 60 K in interplanetary orbits. Because the system does not use refrigerators for its cooling system, the spacecraft can achieve an HTS coil with low power consumption, small mass, and low cost.

  4. HTS-FCL EMTDC model considering nonlinear characteristics on fault current and temperature

    NASA Astrophysics Data System (ADS)

    Yoon, Jae-Young; Lee, Seung-Ryul

    2010-06-01

    One of the most serious problems of the KEPCO system is a higher fault current than the CB(Circuit breaker's SCC (Short Circuit Capacity). There are so many alternatives to reduce the higher fault current, such as the isolation of bus ties, enhancement of the CB's SCC, and the application of HVDC-BTB (Back to Back) or FCL (fault current limiter). However, these alternatives have drawbacks from the viewpoint of system stability and cost. As superconductivity technology has been developed, the resistive type (R-type) HTS-FCL (High Temperature Superconductor Fault Current Limiter) offers one of the important alternatives in terms of power loss and cost reduction in solving the fault current problem. To evaluate the accurate transient performance of R-type HTS-FCL, it is necessary for the dynamic simulation model to consider transient characteristics during the quenching and the recovery state. Against this background, this paper presents the new HTS-FCL EMTDC (Electro-Magnetic Transients including Direct Current) model considering the nonlinear characteristics on fault current and temperature.

  5. Power electronics performance in cryogenic environment: evaluation for use in HTS power devices

    NASA Astrophysics Data System (ADS)

    Pereira, P.; Valtchev, S.; Pina, J.; Gonçalves, A.; Ventim Neves, M.; Rodrigues, A. L.

    2008-02-01

    Power electronics (PE) plays a major role in electrical devices and systems, namely in electromechanical drives, in motor and generator controllers, and in power grids, including high-voltage DC (HVDC) power transmission. PE is also used in devices for the protection against grid disturbances, like voltage sags or power breakdowns. To cope with these disturbances, back-up energy storage devices are used, like uninterruptible power supplies (UPS) and flywheels. Some of these devices may use superconductivity. Commercial PE semiconductor devices (power diodes, power MOSFETs, IGBTs, power Darlington transistors and others) are rarely (or never) experimented for cryogenic temperatures, even when designed for military applications. This means that its integration with HTS power devices is usually done in the hot environment, raising several implementation restrictions. These reasons led to the natural desire of characterising PE under extreme conditions, e. g. at liquid nitrogen temperatures, for use in HTS devices. Some researchers expect that cryogenic temperatures may increase power electronics' performance when compared with room-temperature operation, namely reducing conduction losses and switching time. Also the overall system efficiency may increase due to improved properties of semiconductor materials at low temperatures, reduced losses, and removal of dissipation elements. In this work, steady state operation of commercial PE semiconductors and devices were investigated at liquid nitrogen and room temperatures. Performances in cryogenic and room temperatures are compared. Results help to decide which environment is to be used for different power HTS applications.

  6. AC loss evaluation of an HTS insert for high field magnet cooled by cryocoolers

    NASA Astrophysics Data System (ADS)

    Kajikawa, Kazuhiro; Awaji, Satoshi; Watanabe, Kazuo

    2016-12-01

    AC losses in a high temperature superconducting (HTS) insert coil for 25-T cryogen-free superconducting magnet during its initial energization are numerically calculated under the assumption of slab approximation. The HTS insert consisting of 68 single pancakes wound using coated conductors generates a central magnetic field of 11.5 T in addition to the contribution of 14.0 T from a set of low temperature superconducting (LTS) outsert coils. Both the HTS insert and the LTS coils are cooled using cryocoolers, and energized simultaneously up to the central field of 25.5 T with a constant ramp rate for 60 min. The influences of the magnitudes and orientations of locally applied magnetic fields, magnetic interactions between turns and transport currents flowing in the windings are taken into account in the calculations of AC losses. The locally applied fields are separated into axial and radial components, and the individual contributions of these field components to the AC losses are simply summed up to obtain the total losses. The AC losses due to the axial fields become major in the beginning of energization, whereas the total losses monotonically increase with time after the AC losses due to the radial fields become major.

  7. Design and development of 500 m long HTS cable system in the KEPCO power grid, Korea

    NASA Astrophysics Data System (ADS)

    Sohn, S. H.; Lim, J. H.; Yang, B. M.; Lee, S. K.; Jang, H. M.; Kim, Y. H.; Yang, H. S.; Kim, D. L.; Kim, H. R.; Yim, S. W.; Won, Y. J.; Hwang, S. D.

    2010-11-01

    In Korea, two long-term field demonstrations for high temperature superconducting (HTS) cable have been carried out for several years; Korea Electric Power Corporation (KEPCO) and LS Cable Ltd. (LSC) independently. Encouraged at the result of the projects performed in parallel, a new project targeting the real grid operation was launched in the fourth quarter of 2008 with the Korean government's financial support. KEPCO and LSC are jointly collaborating in the selection of substation, determination of cable specification, design of cryogenic system, and the scheme of protection coordination. A three phase 500 m long HTS cable at a distribution level voltage of 22.9 kV is to be built at 154/22.9 kV Icheon substation located in near Seoul. A hybrid cryogenic system reflecting the contingency plan is being designed including cryocoolers. The HTS cable system will be installed in the second quarter of 2010, being commissioned by the fall of 2010. This paper describes the objectives of the project and design issues of the cable and cryogenic system in detail.

  8. Results of KEPCO HTS cable system tests and design of hybrid cryogenic system

    NASA Astrophysics Data System (ADS)

    Lim, J. H.; Sohn, S. H.; Yang, H. S.; Hwang, S. D.; Kim, D. L.; Ryoo, H. S.; Choi, H. O.

    2010-11-01

    In order to investigate the compatibility as a power utility facility, Korea Electric Power Corporation (KEPCO) had installed a 22.9 kV, 1250 A, 100 m long high temperature superconducting (HTS) power cable system. Using the HTS cable, various tests have been performed to investigate electrical and thermo-mechanical properties. Since 2005, a series of thermal cycle tests between liquid nitrogen (LN2) and ambient temperatures have been conducted using a vacuum-pump driven open-loop cryogenic system with a capacity of 3 kW. In the tests, although the open-loop cryogenic system was reliable to operate the HTS cable system, it was not effective in economic view point because LN2 consumption was larger than expected. In order to secure against unexpected emergencies and solve the problem of LN2 consumption, a hybrid cryogenic system was designed and installed. A stirling cryocooler was employed and combined with the open-loop cryogenic system. Considering the average heat load at rated condition, the cooling capacity of the cryocooler was determined to 4 kW at 77 K. In this paper, results of performance tests and the design of the hybrid cooling system are presented.

  9. [Treating anisometric amblyopia with HTS Amblyopia iNet Software--preliminary results].

    PubMed

    Avram, Elena; Stănilă, Adriana

    2013-01-01

    Amblyopia or "lazy eye" represents a disorder of the visual system characterized by poor vision in an eye that is otherwise physically normal. Anisometropia, the condition in which the two eyes have an unequal refractive error, is considered the second most common cause of amblyopia. The purpose of this study is to determine the efficiency of HTS Amblyopia iNet Software by studying the progress of visual acuity, contrast sensitivity and stereopsis vision in anisometropic amblyopic children. 5 patients (age: 5-13 years), treated with HTS Amblyopia iNet Software at OftaTotal Clinic from Sibiu, between 2010-2013, participated in this clinical trial. Initially, visual acuity ranged from 0.25 to 0.8, contrast sensitivity from 1.35 to 1.65 Log. Unit. and 1 patient presented stereoscopic vision. After treatment, visual acuity ranged from 0.8 to 1, contrast sensitivity from 1.35 to 1.95 Log. Unit., also all patients presented stereoscopic vision. HTS Amblyopia iNet Software represents an effective modern approach in the treatment of anisometropic amblyopia.

  10. Endotracheal tube fixation methods for optimal stability: a comparison of adhesive tape, suture, and tape-suture fixation.

    PubMed

    Farbod, Frank; Tuli, Puneet; Robertson, Bernard F; Jackson, Ian T

    2010-07-01

    Accidental extubation of an intubated patient is a serious consideration in the surgical patient. Adequate fixation in the intubated patient is essential to prevent potentially life-threatening complications. Several methods of endotracheal tube fixation have been described in the literature. In this study, we examine 3 common methods of fixation: adhesive tape alone, suture, and tape-suture. Testing occurred in a laboratory setting with 2 fresh cadavers. Endotracheal tubes were inserted, using the methods of fixation in question. We subjected each fixation technique to progressively increasing weight to determine which technique is most resistant to accidental removal. We found that fixation of the tube by combining tape around the tube with a suture through the tape is the best noninvasive technique of the 3 methods evaluated in cases where movement of the head is anticipated.

  11. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  12. Kinesio Tape and Shoulder-Joint Position Sense

    PubMed Central

    Aarseth, Lindsay M.; Suprak, David N.; Chalmers, Gordon R.; Lyon, Lonnie; Dahlquist, Dylan T.

    2015-01-01

    Context Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. Objective To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Intervention(s) Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. Main Outcome Measure(s) We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Results Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω2 = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω2 = .002), position (ω2 = .072), and tape by position (ω2 = .027). Conclusions At 90° of elevation, shoulder JPS was impaired by the application of KT. PMID:26090707

  13. ARQiv-HTS, a versatile whole-organism screening platform enabling in vivo drug discovery at high-throughput rates.

    PubMed

    White, David T; Eroglu, Arife Unal; Wang, Guohua; Zhang, Liyun; Sengupta, Sumitra; Ding, Ding; Rajpurohit, Surendra K; Walker, Steven L; Ji, Hongkai; Qian, Jiang; Mumm, Jeff S

    2016-12-01

    The zebrafish has emerged as an important model for whole-organism small-molecule screening. However, most zebrafish-based chemical screens have achieved only mid-throughput rates. Here we describe a versatile whole-organism drug discovery platform that can achieve true high-throughput screening (HTS) capacities. This system combines our automated reporter quantification in vivo (ARQiv) system with customized robotics, and is termed 'ARQiv-HTS'. We detail the process of establishing and implementing ARQiv-HTS: (i) assay design and optimization, (ii) calculation of sample size and hit criteria, (iii) large-scale egg production, (iv) automated compound titration, (v) dispensing of embryos into microtiter plates, and (vi) reporter quantification. We also outline what we see as best practice strategies for leveraging the power of ARQiv-HTS for zebrafish-based drug discovery, and address technical challenges of applying zebrafish to large-scale chemical screens. Finally, we provide a detailed protocol for a recently completed inaugural ARQiv-HTS effort, which involved the identification of compounds that elevate insulin reporter activity. Compounds that increased the number of insulin-producing pancreatic beta cells represent potential new therapeutics for diabetic patients. For this effort, individual screening sessions took 1 week to conclude, and sessions were performed iteratively approximately every other day to increase throughput. At the conclusion of the screen, more than a half million drug-treated larvae had been evaluated. Beyond this initial example, however, the ARQiv-HTS platform is adaptable to almost any reporter-based assay designed to evaluate the effects of chemical compounds in living small-animal models. ARQiv-HTS thus enables large-scale whole-organism drug discovery for a variety of model species and from numerous disease-oriented perspectives.

  14. Polyepitope protein incorporated the HIV-1 mimotope recognized by monoclonal antibody 2G12.

    PubMed

    Karpenko, Larisa I; Scherbakova, Nadezhda S; Chikaev, Anton N; Tumanova, Olga Yu; Lebedev, Leonid R; Shalamova, Lyudmila A; Pyankova, Olga G; Ryzhikov, Alexander B; Ilyichev, Alexander A

    2012-04-01

    A major goal in HIV-1 vaccine research is to develop an immunogen that can elicit broadly neutralizing antibodies that efficiently neutralize a wide range of the HIV-1 subtypes. Using biopanning procedure we have selected linear peptide VGAFGSFYRLSVLQS mimicking the structure of discontinuous binding sites of broadly neutralizing antibodies 2G12 from phage peptide library. As a protein carrier, we used the earlier designed artificial polyepitope immunogen named TBI (T- and B-cell immunogen), which comprises B-cell and T-helper epitopes from the HIV-1 Env and Gag proteins. On the base of selected peptide mimotope VGAFGSFYRLSVLQS the artificial protein TBI-2g12 was constructed and its immunogenic properties was investigated. It was shown that the TBI-2g12 as well as the original TBI induces antibodies that recognize HIV-1 proteins and TBI protein using ELISA and immunoblotting. However only anti-TBI-2g12 serum recognized the synthetic peptide mimotope VGAFGSFYRLSVLQS, whereas the antibodies against original TBI don't recognize it. The neutralization assay demonstrated that serum antibodies of the mice immunized with TBI-2g12 possess virus neutralizing activity. The addition of selected peptide leads to inhibition neutralizing activity of anti- TBI-2g12 serum. We conclude from these results that immunogen TBI-2g12 containing the selected peptide VGAFGSFYRLSVLQS elicits HIV-1 neutralizing antibodies during immunization. Our data suggest that this immunogen may be useful in designing effective HIV-vaccine candidates.

  15. The NT digital micro tape recorder

    NASA Technical Reports Server (NTRS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  16. Effect of Elastic Compression Stocking (ECS) on Leg Veins During 2G Centrifugation

    NASA Astrophysics Data System (ADS)

    Arbeille, Ph.; Kaspransky, R.

    2008-06-01

    Objective: evaluate the calf vein response to hypergravity, and check the efficiency of elastic compression stocking (ECS) in preventing their distension. Method: Tibial (Tib csa) and Gastrocnemius (Gast csa) vein cross section area were investigated by echography. The subject was submitted to (a) 10 min stand test (ST), (b) 2G centrifugation for 2 min, (c) 10 min ST, with and without ECS. Results: Centrifugation at 2G induced a higher vein distension for both Gast and Tib vein compare to ST. At 2G centrifugation, ECS reduced the amplitude of the csa increase and limited the max vein csa to the ST value without ECS.

  17. AC transport current losses of multifilamentary Bi(2223) tapes with varying filament geometries

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Däumling, M.; Quilitz, M.; Goldacker, W.

    1998-02-01

    We have measured the ac transport current loss of eight different Bi(2223) tapes with varying filament geometries in the frequency range from 13 to 500 Hz at 77 K. The investigated tapes have an Ag sheath (i.e. 37 or 703 filaments) or a modified sheath using AgMg. Furthermore tapes with novel geometries such as multifilamentary wire-in-tube (WIT) tapes and jelly-roll tapes have been studied. In addition we have investigated twisted tapes with a twist-pitch of 1.4 cm in the 37 filamentary Ag and the 85 filamentary AgMg tapes. To compare these tapes with different Ic values we calculated the loss factors of the tapes. We find that all the loss factors lay within the limits given for an elliptical or a strip like conductor. Furthermore we find differences in the loss factors due to the filament geometries.

  18. Kinesiology tape does not facilitate muscle performance: A deceptive controlled trial.

    PubMed

    Poon, K Y; Li, S M; Roper, M G; Wong, M K M; Wong, O; Cheung, R T H

    2015-02-01

    Kinesiology tape (KinTape) is a therapeutic tape without much understanding of its mechanism. KinTape claims to increase cutaneous stimulation, which facilitates motor unit firing, and consequently improves functional performance; however these, benefits could be due to placebo effects. This study investigated the true effects of KinTape by a deceptive, randomized, and controlled trial. Thirty healthy participants performed isokinetic testing of three taping conditions: true facilitative KinTape, sham KinTape, and no KinTape. The participants were blindfolded during the evaluation. Under the pretense of applying adhesive muscle sensors, KinTape was applied to their quadriceps in the first two conditions. Normalized peak torque, normalized total work, and time to peak torque were measured at two angular speeds (60°/s and 180°/s) and analyzed with one-way repeated measures ANOVA. Participants were successfully deceived and they were ignorant about KinTape. No significant differences were found between normalized peak torque, normalized total work, and time to peak torque at 60°/s or 180°/s (p = 0.31-0.99) between three taping conditions. The results showed that KinTape did not facilitate muscle performance in generating higher peak torque, yielding a greater total work, or inducing an earlier onset of peak torque. These findings suggest that previously reported muscle facilitatory effects using KinTape may be attributed to placebo effects.

  19. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  20. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  1. Electric currents in REBaCuO superconducting tapes

    NASA Astrophysics Data System (ADS)

    Jirsa, M.; Rameš, M.; Ďuran, I.; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-04-01

    Magnetic induction and current transport techniques were employed to test the electromagnetic performance of 22 samples of superconducting REBaCuO tapes of several manufacturers with the aim to select the best candidates for wiring new generation superconducting magnets for fusion reactors. An extraordinary shape of pinning force density as a function of magnetic field was observed in ‘advanced pinning, AP’ SuperPower tapes. The induced currents enabled us to classify the tapes and show the best ones, at low temperatures and high magnetic fields on the one hand and at high temperatures and low magnetic fields on the other hand. Transport current experiments confirmed the results. Moreover, they provided information on current anisotropy, which appeared to be specific for each tape type. The present results formed a basis for the ongoing study of neutron irradiation impact on the tapes’ properties. The first experiment showed that neutron irradiation by the fluence of 2.1 E22 m‑2 either enhances, reduces, or has no effect on the tape’s properties, according to the tape pinning structure.

  2. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  3. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  4. The ultratough peeling of elastic tapes from viscoelastic substrates

    NASA Astrophysics Data System (ADS)

    Afferrante, L.; Carbone, G.

    2016-11-01

    The peeling of an elastic thin tape from a flat smooth viscoelastic substrate is investigated. Based on a Green function approach and on the translational invariance, a closed form analytical solution is proposed, which takes into account the viscoelastic dissipation in the substrate material. We find that peeling is prevented from taking place, only when the external force is smaller than the one predicted by Kendall's formula for elastic tapes on rigid substrates. However, we also find that, regardless of the value of the applied force, steady state detachment may occur when the elastic tape is sufficiently stiff. In this case, the constant peeling velocity can be modulated by properly defining the geometrical parameters and the material properties of tape and viscoelastic foundation. On the other hand, for relatively high peeling angles or compliant tapes a threshold value of the peeling force is found, above which the steady-state equilibrium is no longer possible and unstable detachment occurs. The present study contributes to shed light on the behavior of pressure sensitive adhesives in contact with viscoelastic substrates like the human skin. At the same time, it can be considered a first step towards a better understanding of the effect of viscoelastic dissipation on the fracture behavior of solids.

  5. Combinatorial study of ceramic tape-casting slurries.

    PubMed

    Liu, Zhifu; Wang, Yiling; Li, Yongxiang

    2012-03-12

    Ceramic tape-casting slurries are complex systems composed of ceramic powder, solvent, and a number of organic components. Conventionally, the development of ceramic tape-casting slurries is time-consuming and of low efficiency. In this work, combinatorial approaches were applied to screen the ethanol and ethyl-acetate binary solvent based slurry for ceramic green tape-casting. The combinatorial libraries were designed considering the variation of the amount of PVB (Poly vinyl-butyral) binder, polyethylene-400, and butyl-benzyl-phthalate plasticizers, and glyceryl triacetate dispersant. A parallel magnetic stirring process was used to make the combinatorial slurry library. The properties mapping of the slurry library was obtained by investigating the sedimentation and rheological characteristics of the slurries. The slurry composition was refined by scaling up the experiments and comparing the microstructure, mechanical property, and sintering behavior of green tapes made from the selected slurries. Finally, a kind of ethanol-ethyl acetate binary solvent based slurry system suitable for making X7R dielectric ceramic green tapes was achieved.

  6. Relative electron dosimetry using the Scanditronix-Wellhoefer beam imaging system-2G

    SciTech Connect

    Nygaard, Kirsten . E-mail: kirsten.nygaard@helse-bergen.no; Odland, Odd Harald; Muren, Ludvig Paul

    2006-10-01

    The Beam Imaging System 2G (BIS-2G) from Scanditronix-Wellhoefer is a two-dimensional (2D) charge-coupled device (CCD)-camera that measures the scintillation light produced by incident radiation. We examined the performance of the BIS-2G as a tool in quality control of patient boluses. In an attempt to simplify the production of the patient boluses, bolus edges were built as staircases and the dose distributions were measured and compared to the dose profiles below corresponding sloped bolus edges. Perspex plates covering half the irradiated field were used as generalized bolus edges. All BIS-2G measurements were performed using buildup of solid water while a diode measured corresponding dose profiles in a water phantom. Below the patient boluses, regions with doses < 95% and > 107% of the prescribed dose were defined. Below the edge, the relative doses measured by the BIS-2G were generally within 3% in dose and 3 mm in position compared to the diode measurements. Close to the field edge below the bolus, the BIS-2G measurements were in some cases as much as 7% lower in dose than the diode measurements. The BIS-2G measurements revealed hotspots below the patient boluses covering 1-16% of the total irradiated area. The highest point dose measured below the patient boluses ranged from 105% to 125% of the prescribed dose. For all bolus thicknesses, each edge in the staircase bolus caused a fluctuation in dose and increased the maximum dose compared to the sloped edge. For several cases, the maximum dose increased with 13% in relative dose, e.g., from 103% to 116%. The BIS-2G was found to be a useful tool in quality control of patient boluses, revealing large hot spots in the treatment volume for several patients. Bolus edges built as staircases cause considerable dose fluctuations and increase the maximum dose, and can therefore not be recommended.

  7. 40 CFR Appendix A-2 to Part 60 - Test Methods 2G through 3C

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 8 2012-07-01 2012-07-01 false Test Methods 2G through 3C A Appendix A-2 to Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED) Pt. 60, App. A-2 Appendix A-2 to Part 60—Test Methods 2G through 3C Method...

  8. 40 CFR Appendix A-2 to Part 60 - Test Methods 2G through 3C

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 7 2011-07-01 2011-07-01 false Test Methods 2G through 3C A Appendix A-2 to Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED) Pt. 60, App. A-2 Appendix A-2 to Part 60—Test Methods 2G through 3C Method...

  9. 40 CFR Appendix A-2 to Part 60 - Test Methods 2G through 3C

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 7 2010-07-01 2010-07-01 true Test Methods 2G through 3C A Appendix A-2 to Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED) Pt. 60, App. A-2 Appendix A-2 to Part 60—Test Methods 2G through 3C...

  10. 40 CFR Appendix A-2 to Part 60 - Test Methods 2G through 3C

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 8 2013-07-01 2013-07-01 false Test Methods 2G through 3C A Appendix A-2 to Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED) Pt. 60, App. A-2 Appendix A-2 to Part 60—Test Methods 2G through 3C Method...

  11. Removal of an eroded transobturator tape from the bladder using laser cystolithotripsy and cystoscopic resection.

    PubMed

    Feiner, Benny; Auslender, Ron; Mecz, Yoel; Lissak, Arie; Stein, Avi; Abramov, Yoram

    2009-03-01

    This case presentation describes a unique minimally invasive technique of treating transobturator tape erosion into the urinary bladder with calculus growth. A 42-year-old woman was admitted for recurrent urinary tract infections, 9 months after a transobturator tape procedure. Pelvic sonography, followed by cystourethroscopy, demonstrated an eroded tape in the bladder with heavy calculus growth and diffuse mucosal inflammation. The calculus was fragmented by using laser cystolithotripsy, and the tape was excised and removed by using cystoscopic resection. Intravesical tape erosion with calculus growth can complicate transobturator tape procedures, and is amenable to transurethral laser cystolithotripsy and cystoscopic resection.

  12. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  13. Critical Current Measurements in Commercial Tapes, Coils, and Magnets.

    NASA Astrophysics Data System (ADS)

    Gubser, D. U.; Soulen, R. J., Jr.; Fuller-Mora, W. W.; Francavilla, T. L.

    1996-03-01

    We have measured a number of tapes, coils, and magnets produced by commercial vendors and determined their properties as functions of magnetic field and temperature. The tapes were measured at the National High Magnetic Field Laboratory in magnetic fields to 20 tesla and at temperatures of 4.2 K, 27 K, 65 K, and 77 K. For the tapes we report critical currents and current-voltage characteristics. Six inch diameter coils were measured at NRL in zero magnetic field. Critical currents, current-voltage characteristics, and reliability studies are reported for the coils. Larger 10 inch diameter coils, which are to be used in a 200 hp superconducting motor, were also measured and results will be presented. The talk will also review the status of the most recent tests of the superconducting motor.

  14. AC loss measurements of twisted and untwisted BSCCO multifilamentary tapes

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Nishioka, Takamasa; Oh, Sang-Soo

    2005-01-01

    AC losses in twisted and untwisted BSCCO multifilamentary superconducting tapes with Ag matrix developed in DAPAS program were measured by an electrical method. Magnetization and transport losses were measured by a pick-up coil and by a voltage taps. Total AC loss during simultaneous application of AC transport current and an AC transverse magnetic field was given by the sum of the magnetization and transport losses measured during this simultaneous application. The magnetization loss without transport current of untwisted and twisted tapes was measured first to evaluate the effect of twisting to decouple filaments. Then, the total AC loss of the twisted tape was measured in transverse magnetic fields with various amplitudes and orientations, while the amplitude of the transport current was fixed. The measured total AC loss in a parallel transverse magnetic field was compared with some theoretical models to study the detailed characteristics of the measured total AC loss of the sample.

  15. Experimental Investigations of Woven Textile Tape as Strain Sensor

    NASA Astrophysics Data System (ADS)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  16. The HABP2 G534E polymorphism does not increase nonmedullary thyroid cancer risk in Hispanics

    PubMed Central

    Bohórquez, Mabel E; Estrada, Ana P; Stultz, Jacob; Sahasrabudhe, Ruta; Williamson, John; Lott, Paul; Duque, Carlos S; Donado, Jorge; Mateus, Gilbert; Bolaños, Fernando; Vélez, Alejandro; Echeverry, Magdalena

    2016-01-01

    Familial nonmedullary thyroid cancer (NMTC) has not been clearly linked to causal germline variants, despite the large role that genetic factors play in risk. Recently, HABP2 G534E (rs7080536A) has been implicated as a causal variant in NMTC. We have previously shown that the HABP2 G534E variant is not associated with TC risk in patients from the British Isles. Hispanics are the largest and the youngest minority in the United States and NMTC is now the second most common malignancy in women from this population. In order to determine if the HABP2 G534E variant played a role in NMTC risk among Hispanic populations, we analyzed 281 cases and 1105 population-matched controls from a multicenter study in Colombia, evaluating the association through logistic regression. We found that the HABP2 G534E variant was not significantly associated with NMTC risk (P=0.843) in this Hispanic group. We also stratified available clinical data by multiple available clinicopathological variables and further analyzed the effect of HABP2 on NMTC presentation. However, we failed to detect associations between HABP2 G534E and NMTC risk, regardless of disease presentation (P≥0.273 for all cases). Therefore, without any significant associations between the HABP2 G534E variant and NMTC risk, we conclude that the variant is not causal of NMTC in this Hispanic population. PMID:27097599

  17. Bone metabolism and formation of mice bred in a 2G environment

    NASA Astrophysics Data System (ADS)

    Kita, S.; Iwasaki, K.; Onishi, R.; Fujisawa, M.; Kim, H.; Shibata, S.; Ito, M.

    2003-10-01

    The purpose of this study is to reveal the effect of chronic hypergravity exposure on the bone formation and the bone metabolism when mammals produce offspring in a 2G environment. We measured the length and width of the thighbone, the length of the pelvis, the width of the pelvic cavity and the width of the fourth cervical vertebra on the second (F2) and the third (F3) generation mice bred in a 2G environment every ten days from 20 days old to 60 days old in an experiment on bone formation. In an experiment on bone metabolism, we measured calcium and phosphorus in the bones of the F3 in the 2G group.Ratios of the thighbone length, pelvis length, pelvic cavity width, and fourth cervical vertebra width versus the body length were calculated.These ratios were higher in the 2G group than the control group during all measuring periods.Calcium and phosphorus concentrations in the thighbone and the lumbar vertebra were lower in the 2G group than in the control group. However, the calcium and phosphorus concentrations in the cervical vertebrae of the 2G group were higher. These results suggest that the influence of gravity load may vary in the bones.

  18. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  19. Mirror-touch and ticker tape experiences in synesthesia.

    PubMed

    Chun, Charlotte A; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2-4%) and sequence-space synesthesia (9-14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes.

  20. Cryogenic experiences during W7-X HTS-current lead tests

    SciTech Connect

    Richter, Thomas; Lietzow, Ralph

    2014-01-29

    The Karlsruhe Institute of Technology (KIT) was responsible for design, production and test of the High Temperature Superconductor (HTS) current leads (CL) for the stellerator Wendelstein 7-X (W7-X). 16 current leads were delivered. Detailed prototype tests as well as the final acceptance tests were performed at KIT, using a dedicated test cryostat assembled beside and connected to the main vacuum vessel of the TOSKA facility. A unique feature is the upside down orientation of the current leads due to the location of the power supplies in the basement of the experimental area of W7-X. The HTS-CL consists of three main parts: the cold end for the connection to the bus bar at 4.5 K, the HTS part operating in the temperature range from 4.5 K to 65 K and a copper heat exchanger (HEX) in the temperature range from 65 K to room temperature, which is cooled with 50 K helium. Therefore in TOSKA it is possible to cool test specimens simultaneously with helium at two different temperature levels. The current lead tests included different scenarios with currents up to 18.2 kA. In total, 10 cryogenic test campaigns with a total time of about 24 weeks were performed till beginning of 2013. The test facility as well as the 2 kW cryogenic plant of ITEP showed a very good reliability. However, during such a long and complex experimental campaign, one has to deal with failures, technical difficulties and incidents. The paper gives a summary of the test performance comprising the test preparation and operation. This includes the performance and reliability of the refrigerator and the test facility with reference to the process measuring and control system, the data acquisition system, as well as the building infrastructure.

  1. Cryogenic experiences during W7-X HTS-current lead tests

    NASA Astrophysics Data System (ADS)

    Richter, Thomas; Lietzow, Ralph

    2014-01-01

    The Karlsruhe Institute of Technology (KIT) was responsible for design, production and test of the High Temperature Superconductor (HTS) current leads (CL) for the stellerator Wendelstein 7-X (W7-X). 16 current leads were delivered. Detailed prototype tests as well as the final acceptance tests were performed at KIT, using a dedicated test cryostat assembled beside and connected to the main vacuum vessel of the TOSKA facility. A unique feature is the upside down orientation of the current leads due to the location of the power supplies in the basement of the experimental area of W7-X. The HTS-CL consists of three main parts: the cold end for the connection to the bus bar at 4.5 K, the HTS part operating in the temperature range from 4.5 K to 65 K and a copper heat exchanger (HEX) in the temperature range from 65 K to room temperature, which is cooled with 50 K helium. Therefore in TOSKA it is possible to cool test specimens simultaneously with helium at two different temperature levels. The current lead tests included different scenarios with currents up to 18.2 kA. In total, 10 cryogenic test campaigns with a total time of about 24 weeks were performed till beginning of 2013. The test facility as well as the 2 kW cryogenic plant of ITEP showed a very good reliability. However, during such a long and complex experimental campaign, one has to deal with failures, technical difficulties and incidents. The paper gives a summary of the test performance comprising the test preparation and operation. This includes the performance and reliability of the refrigerator and the test facility with reference to the process measuring and control system, the data acquisition system, as well as the building infrastructure.

  2. STS-97 Mission Highlights Resource Tape. Part 2

    NASA Technical Reports Server (NTRS)

    2001-01-01

    A continuation of 'STS-97 Mission Highlights Resource Tape, Part 1 of 3' (document ID 20010020281), the activities of flight days four through six are seen. Footage includes the spacewalks performed by Noriega and Tanner, the deployment of the Solar Array Blanket Box (SABB), various shots of Endeavour's payload bay and the International Space Station (ISS), and the deployment of the solar radiators on the ISS. Flight days seven through eleven and Endeavour's landing are shown in 'STS-97 Mission Highlights Resource Tape, Part 3 of 3' (document ID 20010020283).

  3. Improvement in performance of heat exchanger fitted with twisted tape

    SciTech Connect

    Sivashanmugam, P.; Sundaram, S.

    1999-04-01

    The improvement in performance of a double pipe heat exchanger fitted with twisted tape as a turbulence promoter with twist ratios of 15.649, 8.54, 5.882, 4.95, and 4.149 was experimentally studied. A maximum percentage gain of 44.7% in energy transfer rate was obtained for the twisted tape of twist ratio 4.149. For all twist ratios, the gain decreases with the Reynolds number and becomes constant for Reynolds numbers greater than 3,000. The smaller the twist ratio is, the larger the gain in energy for a specific Reynolds number.

  4. Leprosy wound healing with ordinary adhesive tape. A preliminary report.

    PubMed

    Stenström, S; Hallmans, G; De Jongh, A; De Wael, T

    1976-01-01

    The use of adhesive tape as wound treatment in leprosy cases is described and found to be superior to the classical dressing as regards security and facility of application, and for the rapidity and quality of healing. Its use as a "preventive" treatment is stressed. The results of this study seem to justify the following conclusions: The adhesive tape is easy to handle, it heals the leprosy wounds in about half the time necessary for the classical dressing and it costs about 50 times less.

  5. Overview of Challenger Space Shuttle tape-data recovery study

    NASA Astrophysics Data System (ADS)

    Bhushan, B.; Phelan, R. M.

    1987-09-01

    The Challenger Orbiter's magnetic flight recorder tapes underwent six weeks of deterioration in sea water, and could not be unwound without damage to the recording surface. Attention is presently given to the method used to chemically treat the damaged magnesium tape reels in a wash tank, under partial vacuum, with nitric acid and methanol. The treated reel was relubricated before careful unwinding at 0.15 m/min. Over 90 percent of the data blocks from a recorder were readable, and 100 percent of the voice data blocks were recovered.

  6. The status and prospects for flywheels and SMES that incorporate HTS

    NASA Astrophysics Data System (ADS)

    Wolsky, A. M.

    2002-08-01

    With one firm offering to provide SMES with HTS current leads and several other entities developing flywheels with bearings that incorporate bulk ReBaCuO, the progress made toward meeting their technical goals appears promising. Another question needs attention from the research, development, and demonstration (RD&D) community: “Will technical success yield equipment that will sell?” Here, we recall what is being done and review issues touching on the specifications for equipment that customers might want. These specifications pose technical challenges that have received little attention from the community.

  7. Characterization of Hybrid Ferroelectric/HTS Thin Films for Tunable Microwave Components

    NASA Technical Reports Server (NTRS)

    Winters, M. D.; Mueller, C. H.; Bhasin, K. B.; Miranda, F. A.

    1996-01-01

    Since the discovery of High-Temperature-Superconductors (HTS) in 1986, a diversity of HTS-based microwave components has been demonstrated. Because of their low conductor losses, HTS-based components are very attractive for integration into microwave circuits for space communication systems. Recent advancements have made deposition of ferroelectric thin films onto HTS thin films possible. Due to the sensitivity of the ferroelectric's dielectric constant (epsilon(sub r)) to an externally applied electric field (E), ferroelectric/superconducting structures could be used in the fabrication of low loss, tunable microwave components. In this paper, we report on our study of Ba(0.5)Sr(0.5)TiO3/YBa2Cu3O(7-delta) and Ba(0.08)Sr(0.92)TiO3/YBa2Cu3O(7-delta) ferroelectric/superconducting thin films on lanthanum aluminate (LaAlO3) substrates. For the (Ba:Sr, 0.50:0.50) epitaxial sample, a epsilon(sub r) of 425 and a loss tangent (tan delta) of 0.040 were measured at 298 K, 1.0 MHz, and zero applied E. For the same sample, a epsilon(sub r) of 360 and tan delta of 0.036 were obtained at 77 K, 1.0 MHz, and zero applied E. Variations in epsilon(sub r) from 180 to 360 were observed over an applied E range of 0V/cm less than or equal to E less than or equal to 5.62 x 10(exp 4) V/cm with little change in tan delta. However, the range of epsilon(sub r) variation for the polycrystalline (Ba:Sr, 0.08:0.92) sample over 0V/cm less than or equal to E less than or equal to 4.00 x 10(exp 4) V/cm was only 3.6 percent while tan delta increased markedly. These results indicate that a lack of epitaxy between the ferroelectric and superconducting layers decreases tuning and increases microwave losses.

  8. Development of a Flat-plate Cryogenic Oscillating Heat Pipe for Improving HTS Magnet Cooling

    NASA Astrophysics Data System (ADS)

    Natsume, K.; Mito, T.; Yanagi, N.; Tamura, H.

    A new method of including cryogenic oscillating heat pipes (OHPs) in the HTS coil windings as a thermal transport device has been studied. In this work, two type of OHPs are tested in low temperature. Employed working fluids are H2, Ne, N2. We have attained high performance thermal property using a bent-pipe cryogenic OHP as a prototype. Obtained effective conductivities have reached to 46000 W/m K. Then a flat-plate cryogenic OHP has been developed, that is suitable for imbedding in magnet windings. Preliminary experiments have been conducted and the result has been promising.

  9. Improvement of sensitivity of multisample biological immunoassay system using HTS SQUID and magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Tsukamoto, A.; Saitoh, K.; Sugita, N.; Kuma, H.; Sugiura, Y.; Hamaoka, S.; Hamasaki, N.; Enpuku, K.

    2006-10-01

    Recently, we have developed a prototype magnetic immunoassay system using a high temperature superconductor (HTS) superconducting quantum interference device (SQUID) to investigate the performance and usability of the magnetic immunoassay. In this study, we improved the immunoassay system to heighten the sensitivity of the immunoassay measurement. To reduce the SQUID-to-sample distance, we introduced a structure to compensate for thermal shrinkage in the cryostat and reduce the warpage of the window. The shape of pickup coil was also optimized to improve the field sensitivity. After these improvements, the magnetic signal intensity from Fe3O4 nanoparticles became about two times stronger than that achieved by our original system.

  10. Two Methods for a First Order Hardware Gradiometer Using Two HTS SQUID's

    SciTech Connect

    Espy, M.A.; Flynn, E.R.; Kraus, R.H., Jr.; Matlachov, A.

    1998-09-15

    Two different systems for noise cancellation (first order gradiometers) have been developed using two similar high temperature superconducting (HTS) SQUIDs. ''Analog'' gradiometry is accomplished in hardware by either (1) subtracting the signals from the sensor and background SQUIDs at a summing amplifier (parallel technique) or (2) converting the inverted background SQUID signal to a magnetic field at the sensor SQUID (series technique). Balance levels achieved are 2000 and 1000 at 20 Hz for the parallel and series methods respectively. The balance level as a function of frequency is also presented. The effect which time delays in the two sets of SQUID electronics have on this balance level is presented and discussed.

  11. Two methods for a first order hardware gradiometer using two HTS SQUIDs

    SciTech Connect

    Espy, M.A.; Flynn, E.R.; Kraus, R.H. Jr.; Matlachov, A.

    1998-12-31

    Two different systems for noise cancellation (first order gradiometers) have been developed using two similar high temperature superconducting (HTS) SQUIDs. Analog gradiometry is accomplished in hardware by either (1) subtracting the signals from the sensor and background SQUIDs at a summing amplifier (parallel technique) or (2) converting the inverted background SQUID signal to a magnetic field at the sensor SQUID (series technique). Balance levels achieved are 2000 and 1000 at 20 Hz for the parallel and series methods respectively. The balance level as a function of frequency is also presented. The effect which time delays in the two sets of SQUID electronics have on this balance level is presented and discussed.

  12. Numerical calculation of primary slot leakage inductance of a Single-sided HTS linear induction motor used for linear metro

    NASA Astrophysics Data System (ADS)

    Li, Dong; Wen, Yinghong; Li, Weili; Fang, Jin; Cao, Junci; Zhang, Xiaochen; Lv, Gang

    2017-03-01

    In the paper, the numerical method calculating asymmetric primary slot leakage inductances of Single-sided High-Temperature Superconducting (HTS) Linear Induction Motor (HTS LIM) is presented. The mathematical and geometric models of three-dimensional nonlinear transient electromagnetic field are established and the boundary conditions are also given. The established model is solved by time-stepping Finite Element Method (FEM). Then, the three-phase asymmetric primary slot leakage inductances under different operation conditions are calculated by using the obtained electromagnetic field distribution. The influences of the special effects such as longitudinal end effects, transversal edge effects, etc. on the primary slot leakage inductance are investigated. The presented numerical method is validated by experiments carried out on a 3.5 kW prototype with copper wires which has the same structures with the HTS LIM.

  13. Development of Non-destructive Evaluation System Using an HTS-SQUID Gradiometer with an External Pickup Coil

    NASA Astrophysics Data System (ADS)

    Kawano, J.; Kawauchi, S.; Ishikawa, F.; Tanabe, K.

    We are developing a new eddy-current non-destructive evaluation (NDE) system using a high-temperature superconducting quantum interference device (HTS-SQUID) gradiometer with the aim of applying it to power plants. Electric power facilities such as ducts and vessels are generally untransportable because of their size, and thus it is difficult to apply a conventional SQUID NDE system. The new NDE system employs an external Cu pickup coil which is supposed to be driven flexibly by a robot arm at room temperature and an HTS-SQUID chip which is placed in a magnetically shielded vessel. In the present research, we investigated the performance of an HTS-SQUID sensor connected with external pickup coils before mounting them to a robot arm. By varying the Cu coil conditions such as their sizes, the number of turns, and the diameter of wire, we qualitatively evaluated the frequency dependence of the effective area and the cutoff frequency.

  14. Influence of AC external magnetic field on guidance force relaxation between HTS bulk and NdFeB guideway

    NASA Astrophysics Data System (ADS)

    Zhang, Longcai; Wang, Suyu; Wang, Jiasu; Zheng, Jun

    2007-12-01

    Superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the HTS bulks are always exposed to time-varying external magnetic field, which is generated by the inhomogeneous surface magnetic field of the NdFeB guideway. So it is required to study whether the guidance force of the bulks is influenced by the inhomogeneity. In this paper, we studied the characteristics of the guidance force relaxation between the HTS bulk and the NdFeB guideway by an experiment in which AC external magnetic field generated by an electromagnet was used to simulate the time-varying external magnetic field caused by the inhomogeneity of the guideway. From the experiment results, it was found that the guidance force was decreased with the application of the AC external magnetic field, and the decay increased with the amplitude and was almost independent of the frequency.

  15. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  16. Probe molecules (PrM) approach in adverse outcome pathway (AOP) based high throughput screening (HTS): in vivo discovery for developing in vitro target methods

    EPA Science Inventory

    Efficient and accurate adverse outcome pathway (AOP) based high-throughput screening (HTS) methods use a systems biology based approach to computationally model in vitro cellular and molecular data for rapid chemical prioritization; however, not all HTS assays are grounded by rel...

  17. Loss of PLA2G6 leads to elevated mitochondrial lipid peroxidation and mitochondrial dysfunction

    PubMed Central

    Castillo-Quan, Jorge Iván; Bartolome, Fernando; Angelova, Plamena R.; Li, Li; Pope, Simon; Cochemé, Helena M.; Khan, Shabana; Asghari, Shabnam; Bhatia, Kailash P.; Hardy, John; Abramov, Andrey Y.; Partridge, Linda

    2015-01-01

    The PLA2G6 gene encodes a group VIA calcium-independent phospholipase A2 beta enzyme that selectively hydrolyses glycerophospholipids to release free fatty acids. Mutations in PLA2G6 have been associated with disorders such as infantile neuroaxonal dystrophy, neurodegeneration with brain iron accumulation type II and Karak syndrome. More recently, PLA2G6 was identified as the causative gene in a subgroup of patients with autosomal recessive early-onset dystonia-parkinsonism. Neuropathological examination revealed widespread Lewy body pathology and the accumulation of hyperphosphorylated tau, supporting a link between PLA2G6 mutations and parkinsonian disorders. Here we show that knockout of the Drosophila homologue of the PLA2G6 gene, iPLA2-VIA, results in reduced survival, locomotor deficits and organismal hypersensitivity to oxidative stress. Furthermore, we demonstrate that loss of iPLA2-VIA function leads to a number of mitochondrial abnormalities, including mitochondrial respiratory chain dysfunction, reduced ATP synthesis and abnormal mitochondrial morphology. Moreover, we show that loss of iPLA2-VIA is strongly associated with increased lipid peroxidation levels. We confirmed our findings using cultured fibroblasts taken from two patients with mutations in the PLA2G6 gene. Similar abnormalities were seen including elevated mitochondrial lipid peroxidation and mitochondrial membrane defects, as well as raised levels of cytoplasmic and mitochondrial reactive oxygen species. Finally, we demonstrated that deuterated polyunsaturated fatty acids, which inhibit lipid peroxidation, were able to partially rescue the locomotor abnormalities seen in aged flies lacking iPLA2-VIA gene function, and restore mitochondrial membrane potential in fibroblasts from patients with PLA2G6 mutations. Taken together, our findings demonstrate that loss of normal PLA2G6 gene activity leads to lipid peroxidation, mitochondrial dysfunction and subsequent mitochondrial membrane

  18. How To Choose Audio and Video Tape and Cassettes That Best Fit Your Needs

    ERIC Educational Resources Information Center

    Smith, Judson

    1978-01-01

    An audiovisual consultant presents a guide to selecting suitable and cost effective tape and cassettes. He describes and illustrates physical properties of tapes and includes a list of manufacturers and suppliers. (MF)

  19. Harmonic distortion analyzer speeds setup of magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.

    1968-01-01

    Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

  20. Theoretical analysis on ac susceptibility measurements of superconductor tapes

    NASA Astrophysics Data System (ADS)

    Chen, Du-Xing; Sun, Yue-Ming; Li, Shuo; Fang, Jin

    2017-02-01

    Perpendicular ac susceptibility χ ={χ\\prime}-j{χ\\prime \\prime} of a superconducting long tape defined by magnetic moment and determined inductively by magnetic flux is calculated using Brandt’s technique from a power-law dependence of electric field on sheet current density. The requirements of χ measurements to the experimental setup and procedure are discussed based on the calculation results.

  1. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  2. Nucleate boiling of water in twisted-tape swirled flow

    SciTech Connect

    Kudryavtsev, I.S.; Lekakh, B.M.; Paskar, B.L.; Fedorovich, Y.D. )

    1990-01-01

    This paper analyzes nucleate boiling in twisted-tape swirled water flow. The transverse flow velocity in the wall region, generated by the density gradient and acceleration, is estimated. It is concluded that the turbulence has a significant effect on the growth of vapor bubbles, decreasing the rate of nucleate boiling without simultaneously increasing the convective component to compensate for this effect.

  3. A new tape product for optical data storage

    NASA Technical Reports Server (NTRS)

    Larsen, T. L.; Woodard, F. E.; Pace, S. J.

    1993-01-01

    A new tape product has been developed for optical data storage. Laser data recording is based on hole or pit formation in a low melting metallic alloy system. The media structure, sputter deposition process, and media characteristics, including write sensitivity, error rates, wear resistance, and archival storage are discussed.

  4. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  5. Educators Guide to Free Tapes, Scripts, and Transcriptions. Eighteenth Edition.

    ERIC Educational Resources Information Center

    Wittich, Walter A., Ed.; And Others

    This compendium lists 442 tapes, scripts, and transcriptions which are available free of cost to schools and libraries. Of these titles, 259 are new this year. Forty-one of the titles may be kept permanently by the user. Cassettes and videotapes are included in this edition for the first time. The items are listed by topics; accident prevention…

  6. Self-Paced Physics [Talking Book Cassette Tapes].

    ERIC Educational Resources Information Center

    New York Inst. of Tech., Old Westbury.

    As one of three audiovisual media in the U. S. Naval Academy Self-Paced Physics Course, 16 cassette tapes relating to lectures of mechanics, electricity, and magnetism are prepared for enriching and supplementary purposes. The material is designed to be used in combination with the talking book where illustrations, formulas, behavioral objectives,…

  7. The Taped Monologue as Narrative Technique for Reflective Practice

    ERIC Educational Resources Information Center

    Ford, Keith

    2016-01-01

    In this article, I describe how an EFL teacher engaged in a process of reflective practice. As she looked back on her teaching career, she explored the critical incidents, principles, and practices that have informed her present teaching identity. I focus on how a taped monologue narrative technique was used, and on the rationale, practice, and…

  8. STS-46 Special Events Resource Tape, Part 1 of 2

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Footage shows the inflight interviews of the crew of the STS-46 Atlantis Orbiter. An Italian VIP call and press conference (both spoken in Italian) are seen, and Mission Specialist Franklin R. Chang-Diaz participates in a Costa Rican VIP call (spoken in Spanish). See also 'STS-46 Special Events Resource Tape, Part 2 of 2'.

  9. Tape casting and partial melting of Bi-2212 thick films

    SciTech Connect

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  10. Projector Center: Slide-Tape Presentations on a Classroom Budget.

    ERIC Educational Resources Information Center

    Barman, Charles R., Ed.

    1984-01-01

    Presented is a recommended sequence for developing a slide-tape presentation. Steps include selecting a topic, determining objectives for the presentation, constructing a storyboard, writing the script, and recording the script. Comments on use of quotation, sound effects, built-in pauses, and use of student voices are included. (JN)

  11. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  12. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  13. Recorded Readings: A Taped Parent-Tutoring Intervention

    ERIC Educational Resources Information Center

    Kupzyk, Sara; McCurdy, Merilee; Hofstadter, Kristi L.; Berger, Laura

    2011-01-01

    Parent tutoring has been successfully used to increase children's oral reading fluency. However, commonly used procedures pose a challenge for parents who are not proficient in reading or who speak English as a second language. A taped reading program that included listening passage preview, repeated reading, and performance feedback was developed…

  14. Self-Help Audiocassette Tapes: Adjunct to Psychological Counseling.

    ERIC Educational Resources Information Center

    Yamauchi, Kent T.

    1987-01-01

    Argues that use of self-help audiocassette tapes in psychological counseling can accelerate the introduction of therapeutic ideas, promote continuity of counseling between sessions, and reinforce behavioral and attitudinal changes. Discussed rationale and description of a program in which this approach is used in brief counseling of college…

  15. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  16. Advanced Shuttle Simulation Turbulence Tapes (SSTT) users guide

    NASA Technical Reports Server (NTRS)

    Tatom, F. B.; Smith, S. R.

    1981-01-01

    A nonrecursive model (based on von Karman spectra) for atmospheric turbulence along the flight path of the shuttle orbiter was developed which provides for simulation of instantaneous vertical and horizontal gusts at the vehicle center-of-gravity and also for simulation of instantaneous gust gradients. Based on this model, the time series for both gusts and gust gradients was generated and stored on a series of magnetic tapes which are entitled shuttle simulation turbulence tapes (SSTT). The time series are designed to represent atmospheric turbulence from ground level to an altitude of 120,000 meters. An appropriate description of the characteristics of the simulated turbulence stored on the tapes, as well as instructions regarding their proper use are provided. The characteristics of the turbulence series, including the spectral shape, cutoff frequencies, and variation of turbulence parameters with altitude, are discussed. Information regarding the tapes and their use is presented. Appendices provide results of spectral and statistical analyses of the SSTT and examples of how the SSTT should be used.

  17. Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E.; Wieserman, William R.; Niedra, Janis M.

    2005-01-01

    The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

  18. Privacy: The Reporter, the Telephone, and the Tape Recorder.

    ERIC Educational Resources Information Center

    Riley, Sam G.; Wiessler, Joel M.

    Federal and state law provides, for the most part, little specific guidance to persons tape recording their own telephone calls for their own record-keeping purposes. In a specific case, a Pennsylvania newsman was prosecuted in 1972 on charges of wiretapping his own telephone conversations without notice to the other parties in the calls. A review…

  19. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  20. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.