Science.gov

Sample records for 2g hts tapes

  1. Method for Determining Local Current Density in 2G HTS Tapes

    NASA Astrophysics Data System (ADS)

    Bludova, A. I.

    Practically important problem is to determine the density and direction of 2G HTS induced currents at each point on the tape in order to examine its local deviations. This problem is resolved indirectly by spatial measurement of generated magnetic field with a scanning Hall sensor at a given height above the tape surface. Current density is subsequently determined by the Biot-Savart law inversion in Fourier domain. Tikhonov regularization is used in order to increase precision. Method is verified with the model current density reconstruction. Optimal calculation parameters and resulting precision are described.

  2. Enhanced quench propagation in 2G-HTS coils co-wound with stainless steel or anodised aluminium tapes

    NASA Astrophysics Data System (ADS)

    Núñez-Chico, A. B.; Martínez, E.; Angurel, L. A.; Navarro, R.

    2016-08-01

    Early quench detection and thermal stability of superconducting coils are of great relevance for practical applications. Magnets made with second generation high temperature superconducting (2G-HTS) tapes present low quench propagation velocities and therefore slow voltage development and high local temperature rises, which may cause irreversible damage. Since quench propagation depends on the anisotropy of the thermal conductivity, this may be used to achieve an improvement of the thermal stability and robustness of 2G-HTS coils. On pancake type coils, the thermal conductivity along the tapes (coil’s azimuthal direction) is mostly fixed by the 2G-HTS tape characteristics, so that the reduction of anisotropy relies on the improvement of the radial thermal conductivity, which depends on the used materials between superconducting tapes, as well as on the winding and impregnation processes. In this contribution, we have explored two possibilities for such anisotropy reduction: by using anodised aluminium or stainless steel tapes co-wound with the 2G-HTS tapes. For all the analysed coils, critical current distribution, minimum quench energy values and both tangential and radial quench propagation velocities at different temperatures and currents are reported and compared with the results of similar coils co-wound with polyimide (Kapton®) tapes.

  3. Feasibility of a short-period superconducting undulator using 2G HTS tapes.

    SciTech Connect

    Kim, S. H.; Doose, C. L.; Jaski, M. S.; Kasa, M. T. )

    2011-06-01

    This paper presents a design concept of a planar-type superconducting undulator (SCU) using YBCO high-temperature superconductor (HTS) tapes. The SCU has a period length of 15 mm, and the tape conductor has dimensions of 4-mm width and 0.1-mm thickness. It has been shown that the conductor transition from one coil groove to the one in the next period is possible by making a semi-circular concave loop of the tape for continuous winding in the same direction. Non-uniform current distribution in the tape may cause field quality degradation. Assuming a uniform current density in the tape, the engineering critical-current density of the HTS in the coil for the design and the corresponding achievable on-axis peak field at 4.2 K were calculated.

  4. Variation of critical current and n-value of 2G HTS tapes in external magnetic fields of different orientation

    NASA Astrophysics Data System (ADS)

    Sychugov, V. V.; Degtyarenko, P. N.; Ovcharov, A. V.; Shavkin, S. V.; Kruglov, V. S.; Vasiliev, A. L.; Volkov, P. V.; Chesnokov, Yu M.

    2016-09-01

    The in-field orientation dependence of critical current and n-value in second generation high temperature superconductive tapes was investigated. The samples were manufactured by Metalorganic Chemical Vapour Deposition method with BaZrO3 inclusions (SuperPower Inc.) and Pulsed Laser Deposition method (Bruker HTS). For samples of each kind of fabrication techniques we observed higher critical current value in the case of external magnetic field aligned along (or nearby) c-axis direction in comparison with one aligned along ab-plane. We analysed possible reasons for this effect. Angular dependences of the critical current and n-value were investigated. The microstructure images of superconductive layer of studied samples show tilt of BaZrO3 nanorods in MOCVD sample and high density of structural defects for PLD sample.

  5. Synchronous Generator with HTS-2G field coils for Windmills with output power 1 MW

    NASA Astrophysics Data System (ADS)

    Kovalev, K.; Kovalev, L.; Poltavets, V.; Samsonovich, S.; Ilyasov, R.; Levin, A.; Surin, M.

    2014-05-01

    Nowadays synchronous generators for wind-mills are developed worldwide. The cost of the generator is determined by its size and weight. In this deal the implementation of HTS-2G generators is very perspective. The application of HTS 2G field coils in the rotor allows to reduce the size of the generator is 1.75 times. In this work the design 1 MW HTS-2G generator is considered. The designed 1 MW HTS-2G generator has the following parameters: rotor diameter 800 mm, active length 400 mm, phase voltage 690V, rotor speed 600 min-1 rotor field coils with HTS-2G tapes. HTS-2G field coils located in the rotating cryostat and cooled by liquid nitrogen. The simulation and optimization of HTS-2G field coils geometry allowed to increase feed DC current up to 50A. Copper stator windings are water cooled. Magnetic and electrical losses in 1 MW HTS-2G generator do not exceed 1.6% of the nominal output power. In the construction of HTS-2G generator the wave multiplier with ratio 1:40 is used. The latter allows to reduce the total mass of HTS-2G generator down to 1.5 tons. The small-scale model of HTS-2G generator with output power 50 kW was designed, manufactured and tested. The test results showed good agreement with calculation results. The manufacturing of 1 MW HTS-2G generator is planned in 2014. This work is done under support of Rosatom within the frames of Russian Project "Superconducting Industry".

  6. Anisotropy of 2G HTS racetrack coils in external magnetic fields

    NASA Astrophysics Data System (ADS)

    Chudy, Michal; Chen, Yiran; Zhang, Min; Coombs, T. A.

    2013-07-01

    Pancake or racetrack coils wound with second generation high-temperature superconductors (2G HTSs) are important elements for numerous applications of HTS. The applications of these coils are primarily in rotating machines such as motors and generators where they must withstand external magnetic fields from various orientations. The characterization of 2G HTS coils is mostly focused on AC loss assessment, critical current and maximum magnetic field evaluation. In this study, racetrack coils will be placed in different orientations of external magnetic fields—Jc (Ic) versus angle measurements will be performed and interpreted. Full attention is paid to studies of anisotropy Jc versus angle curves for short samples of 2G HTS tapes. As will be shown, the shape of the Jc versus angle curves for tapes has a strong influence on the Jc (Ic) versus angle curves for coils. In this work, a unique and unpredicted behavior of the Jc versus angle curves for the 2G HTS racetrack coils was found. This will be analyzed and fully explained.

  7. A study on the required performance of a 2G HTS wire for HTS wind power generators

    NASA Astrophysics Data System (ADS)

    Sung, Hae-Jin; Park, Minwon; Go, Byeong-Soo; Yu, In-Keun

    2016-05-01

    YBCO or REBCO coated conductor (2G) materials are developed for their superior performance at high magnetic field and temperature. Power system applications based on high temperature superconducting (HTS) 2G wire technology are attracting attention, including large-scale wind power generators. In particular, to solve problems associated with the foundations and mechanical structure of offshore wind turbines, due to the large diameter and heavy weight of the generator, an HTS generator is suggested as one of the key technologies. Many researchers have tried to develop feasible large-scale HTS wind power generator technologies. In this paper, a study on the required performance of a 2G HTS wire for large-scale wind power generators is discussed. A 12 MW class large-scale wind turbine and an HTS generator are designed using 2G HTS wire. The total length of the 2G HTS wire for the 12 MW HTS generator is estimated, and the essential prerequisites of the 2G HTS wire based generator are described. The magnetic field distributions of a pole module are illustrated, and the mechanical stress and strain of the pole module are analysed. Finally, a reasonable price for 2G HTS wire for commercialization of the HTS generator is suggested, reflecting the results of electromagnetic and mechanical analyses of the generator.

  8. Numerical simulation of screening current distribution in HTS tape of high field magnet

    NASA Astrophysics Data System (ADS)

    Itoh, Ryusei; Oga, Yuki; Noguchi, So; Igarashi, Hajime; Ueda, Hiroshi

    2013-01-01

    In recent years, properties of high temperature superconducting (HTS) tapes, especially in-field performance and mechanical strength, have been continuously improved. The HTS tapes have been widely used for high field (>20 T) magnet researches and there are several technical challenges including field attenuation of an HTS magnet by screening currents induced within the HTS tapes. Several publications reported that the screening currents, induced by penetration of self magnetic fields into HTS tapes within an HTS magnet, weakened a field constant of the HTS magnet. The result may demonstrate that the screening current changes an overall current density distribution in HTS tapes and, as a consequence, the generated magnetic field. Therefore, it is necessary to investigate the screening current distribution in an HTS tape. This paper reports numerical simulation of the screening current distribution in an HTS tape of high field magnets using 2D finite element method with the E-J characteristic of the HTS tape taken into account. Self magnetic field distribution and its orientation to the HTS tape are also considered to compute critical currents and locally generated electric fields, two key components to figure out the distribution of screening currents.

  9. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    NASA Astrophysics Data System (ADS)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  10. Influence of Proton Irradiation on Angular Dependence of Second Generation (2G)HTS

    SciTech Connect

    Shiroyanagi, Y.; Greene, G.; Gupta, R.; Sampson, W.

    2011-05-01

    In the Facility for Rare Isotope Beams (FRIB) the quadrupoles in the fragment separator are exposed to very high radiation and heat loads. High Temperature Superconductors (HTS) are a good candidate for these magnets because they can be used at {approx}30-50 K and tolerate higher heat generation than Nb-Ti magnets. Radiation damage studies of HTS wires are crucial to ensure that they will survive in a high radiation environment. HTS wires from two vendors were studied. Samples of 2G HTS wires from SuperPower and American Superconductor (ASC) were irradiated with a 42 {mu}A, 142 MeV proton beam from the Brookhaven Linac Isotope Producer (BLIP). The angular dependence of the critical current was measured in magnetic fields at 77K.

  11. AC loss of a model 5m 2G HTS power cable using wires with NiW substrates

    NASA Astrophysics Data System (ADS)

    Vysotsky, V. S.; Shutov, K. A.; Nosov, A. A.; Polyakova, N. V.; Fetisov, S. S.; Zubko, V. V.; Sytnikov, V. E.; Carter, W. L.; Fleshler, S.; Malozemoff, A. P.; Snitchler, G.

    2010-06-01

    A model 5 m cable prototype was constructed using American Superconductor second generation (2G) high temperature superconductor (HTS) wires - 344 superconductors, produced with the MOD/RABiTSTM process. The model cable consists of two helically counterwound layers of brass-laminated tapes. Twist pitches were calculated to provide uniform current distribution between the two cable layers. The NiW substrates of the tapes were oriented to face radially inward and radially outward for the inner and outer layers of the cable, respectively, to minimize the spacing between the HTS layers and any effects of the weak substrate magnetism. To verify the calculations and design principles, the model cable was instrumented with potential taps and sensors, including Rogowski coils and Hall probes, to measure the current distribution among layers, voltage - current characteristics and other parameters. AC losses in this cable model have been measured and analyzed by use of digital measurements of current and voltage. At low to intermediate currents, they are in the range of a few tenths of a watt per meter, consistent with the ferromagnetic loss of the substrate. Analysis of the individual contributions of the Ni-W substrate and the superconductor hysteresis loss is given.

  12. Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils.

    PubMed

    Hahn, Seung-Yong; Ahn, Min Cheol; Bascuñán, Juan; Yao, Weijun; Iwasa, Yukikazu

    2009-06-01

    This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-as-sembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.

  13. Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils

    PubMed Central

    Hahn, Seung-yong; Ahn, Min Cheol; Bascuñán, Juan; Yao, Weijun; Iwasa, Yukikazu

    2010-01-01

    This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-as-sembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil. PMID:20383282

  14. Magnetic properties of Ni-based substrates for HTS tape

    NASA Astrophysics Data System (ADS)

    Claassen, J. H.; Thieme, C. L. H.

    2008-10-01

    Ni-W alloys are used as the substrate in the manufacture of HTS tape via the RABiTSTM process. Theoretical work has shown that the ferromagnetism in a substrate can affect the ac losses in the superconductor. This occurs in part because of the increased magnetic permeability, which alters the magnetic induction in the superconductor and thereby the loss. Magnetic hysteretic loss in the substrate is an additional contribution to overall ac loss. We report measurements of both permeability and magnetic loss as a function of frequency and magnetic induction for the standard alloy Ni-5W as well as composite substrates incorporating non-magnetic Ni-W alloys. The measurements are done using ac susceptibility at 77 K, at frequencies up to 104 Hz and inductions in the range 1-150 mT. It is shown how to use these results to predict total ac loss in isolated superconducting tape and wound coils. Some important magnetic parameters cannot be obtained with sufficient accuracy using a SQUID or vibrating sample magnetometer, since the size of a sample is limited in these measurements. This makes the demagnetizing factor large enough to degrade the accuracy of a permeability measurement.

  15. Heat Transfer Simulation to Liquid Nitrogen from HTS Tapes at the Overload Currents

    NASA Astrophysics Data System (ADS)

    Zubko, V. V.; Ryabov, S. M.; Fetisov, S. S.; Vysotsky, V. S.

    Knowledge of HTS materials behavior at overload currents is important to design fault current limiters or fault protection systems of electro-technical devices. There are sharp voltage peaks and voltage oscillations during rectangular current pulses (DC current) on HTS tapes cooled by liquid nitrogen. It is common knowledge that a homogeneous liquid can withstand certain amount of overheating before switching to the boiling phase. In the liquid nitrogen during the increase of the heat flux there is superheating (temperature overshoot) and boiling hysteresis takes place. We explain voltage peaks and voltage oscillations by the hysteresis phenomenon in boiling nitrogen during the increase and decrease of the heat flux in the nitrogen which is a result of current redistribution in the HTS tapes. Based on the measurements of voltage and temperature of the HTS tapes during current overload and numerical analysis of the process we estimated the heat-transfer characteristics from the HTS tapes to liquid nitrogen. We also obtained the information about limiting superheating of the liquid nitrogen. The influence of covers of the HTS tapes on superheating of the nitrogen is also discussed.

  16. 2G HTS wires made on 30 μm thick Hastelloy substrate

    NASA Astrophysics Data System (ADS)

    Sundaram, A.; Zhang, Y.; Knoll, A. R.; Abraimov, D.; Brownsey, P.; Kasahara, M.; Carota, G. M.; Nakasaki, R.; Cameron, J. B.; Schwab, G.; Hope, L. V.; Schmidt, R. M.; Kuraseko, H.; Fukushima, T.; Hazelton, D. W.

    2016-10-01

    REBCO (RE = rare earth) based high temperature superconducting (HTS) wires are now being utilized for the development of electric and electromagnetic devices for various industrial, scientific and medical applications. In the last several years, the increasing efforts in using the so-called second generation (2G) HTS wires for some of the applications require a further increase in their engineering current density (J e). The applications are those typically related to high magnetic fields where the higher J e of a REBCO wire, in addition to its higher irreversibility fields and higher mechanical strength, is already a major advantage over other superconducting wires. An effective way to increase the J e is to decrease the total thickness of a wire, for which using a thinner substrate becomes an obvious and attractive approach. By using our IBAD-MOCVD (ion beam assisted deposition-metal organic chemical vapor deposition) technology we have successfully made 2G HTS wires using a Hastelloy® C276 substrate that is only 30 μm in thickness. By using this thinner substrate instead of the typical 50 μm thick substrate and with a same critical current (I c), the J e of a wire can be increased by 30% to 45% depending on the copper stabilizer thickness. In this paper, we report the fabrication and characterization of the 2G HTS wires made on the 30 μm thick Hastelloy® C276 substrate. It was shown that with the optimization in the processing protocol, the surface of the thinner Hastelloy® C276 substrate can be readily electropolished to the quality needed for the deposition of the buffer stack. Same in the architecture as that on the standard 50 μm thick substrate, the buffer stack made on the 30 μm thick substrate showed an in-plane texture with a Δϕ of around 6.7° in the LaMnO3 cap layer. Low-temperature in-field transport measurement results suggest that the wires on the thinner substrate had achieved equivalent superconducting performance, most importantly the I

  17. Design, fabrication and testing of a dipole magnet made with 2G HTS wire

    NASA Astrophysics Data System (ADS)

    Bogdanov, I. V.; Kozub, S. S.; Sytnik, V. V.; Terskiy, I. S.; Tkachenko, L. M.; Trusov, O. V.; Shirshov, L. S.; Smirnov, V. M.; Shuvalov, V. I.; Shcherbakov, P. A.; Molodyk, A. A.; Lee, S. R.; Samoilenkov, S. V.

    2016-10-01

    An HTS dipole magnet with a 1 T (at 77 K) central magnetic field in a 40 × 80 mm2 aperture has been designed, fabricated and tested. The magnet coils were wound with SuperOx 2G HTS wire. The paper describes the magnet design, properties of the magnet materials, and results of calculations and measurements. The central field in the dipole reached 1.12 T at 77 K and 1.66 T at 65 K. In a liquid helium bath the maximum input current of 847 A was limited by the capacity of the power supply, and in that case the central field was 3.03 T. The measurement data were in good agreement with the calculation results.

  18. Manufacturing and test of 2G-HTS coils for rotating machines: Challenges, conductor requirements, realization

    NASA Astrophysics Data System (ADS)

    Oomen, Marijn; Herkert, Werner; Bayer, Dietmar; Kummeth, Peter; Nick, Wolfgang; Arndt, Tabea

    2012-11-01

    We investigate the use of 2nd-generation High-Temperature Superconductors (2G-HTSs) in the rotors of electrical motors and generators. For these devices the conductor must be wound into robust impregnated coils, which are operated in vacuum at temperatures around 30 K, in strong magnetic fields of about 2T. Differences in thermal contraction between the coil former, conductor constituents, impregnation resin, bandage and heat-sink materials (assembled at room temperature) cause mechanical stresses at operating temperature. Rotating-machine operation adds Lorentz forces and challenging centripetal accelerations up to thousands of g. Second generation-HTS conductors withstand large tensile stresses in axial direction and compression in normal direction. However, shear stresses, axial compression, and tension normal to the conductor can cause degradation in superconducting properties. Such stresses can be mitigated by correct choice of materials, coil lay-out and manufacturing process. A certain stress level will remain, which the conductor must withstand. We have manufactured many impregnated round and race-track coils, using different 2G-HTS conductors, and tested them at temperatures from 25 K to 77 K. Degradation of the superconductor in early coils was traced to the mentioned differences in thermal contraction, and was completely avoided in coils produced later. We will discuss appropriate coil-winding techniques to assure robust and reliable superconductor performance.

  19. Analysis of transient state in HTS tapes under ripple DC load current

    NASA Astrophysics Data System (ADS)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  20. An introduction to the design and fabrication progress of a megawatt class 2G HTS motor for the ship propulsion application

    NASA Astrophysics Data System (ADS)

    Moon, Heejong; Kim, Yeong-Chun; Park, Heui-Joo; Yu, In-Keun; Park, Minwon

    2016-03-01

    This paper introduces the design and fabrication progress of a megawatt class 2G high temperature superconductor (HTS) motor for the ship propulsion application at Doosan Heavy Industries and Construction. The purpose of this 2G HTS propulsion motor is to launch the business area for marine applications such as surface ship, submarine, merchant ship etc. The principles and interpretation of the magnetic field for 2G HTS motor and permanent magnet type motors are similar on the basis of 3D design and production. The most important component of an HTS motor is the rotor, which is composed of HTS coil, non-ferrous metal, torque disk, damper, and hollow shaft. A HTS rotor using hastelloy-based 2G HTS coils was designed and built. Open-circuit and short-circuit characteristics of the superconducting motor were investigated and compared with the analysis results at reduced excitation to verify the design. Preliminary testing of a 2G HTS motor has been conducted at a few hundred kilowatts as per the design. Through these results, we anticipate that most of the design criteria can be satisfied. However, we have faced several issues during the testing of the motor and these issues need to be resolved in order to take the design further.

  1. Recent developments in processing HTS silver-clad Bi-2223 tapes, coils and test magnets

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.; Balachandran, U.; Iwasa, Y.; Yunus, M.

    1993-10-01

    Considerable progress has been made in fabricating Bi-2223 high temperature superconductor (HTS) wires and tapes with high critical current densities that are attractive for electric power and high-field magnet applications. Powder-in-tube processed silver-clad Bi-2223 short tape samples, small coils and test magnets have been fabricated and measured at liquid nitrogen (77K), pumped liquid nitrogen (64 K), liquid neon (27K) and liquid helium (4.2K) temperatures. Optimization of thermo-mechanical process parameters have yielded J{sub c}`s in the superconducting core > 4.0 {times} 10{sup 4} A/cm{sup 2} at 77K zero field and > 2.0 {times} 10{sup 5} A/cm{sup 2} at 4.2K, zero field. Long lengths (up to 70 m) of mono-core conductors were fabricated and tested to carry significant amounts of current (23 A, {approximately}15,000 A/cm{sup 2}) at liquid nitrogen temperature. Recent test magnets assembled from pancake wound coils were measured to generate magnetic fields as high as 2.6, 1.8 and 0.36 Tesla at 4.2K, 27K and 77K respectively. These results show promise towards practical utilization of HTS materials.

  2. H-formulation for simulating levitation forces acting on HTS bulks and stacks of 2G coated conductors

    NASA Astrophysics Data System (ADS)

    Sass, F.; Sotelo, G. G.; Junior, R. de Andrade; Sirois, Frédéric

    2015-12-01

    Several techniques to model high temperature superconductors (HTSs) are used throughout the world. At the same time, the use of superconductors in transportation and magnetic bearings promises an increase in energy efficiency. However, the most widespread simulation technique in the literature, the H-formulation, has not yet been used to simulate superconducting levitation. The goal of this work is to present solutions for the challenges concerning the use of the H-formulation to predict the behavior of superconducting levitators built either with YBCO bulks or stacks of 2G wires. It is worth mentioning the originality of replacing bulks with HTS stacks in this application. In our simulation methodology, the movement between the HTS and the permanent magnet was avoided by restricting the simulation domain to the HTS itself, which can be done by applying appropriate boundary conditions and analytical expressions for the source field. Commercial finite element software was used for the sake of ease of implementation. Simulation results were compared with experimental data, showing good agreement. We conclude that the H-formulation is suitable for problems involving moving objects and is a good alternative to other approaches for simulating superconducting magnetic bearings.

  3. Basic study of HTS magnet using 2G wires for maglev train

    NASA Astrophysics Data System (ADS)

    Ogata, M.; Miyazaki, Y.; Hasegawa, H.; Sasakawa, T.; Nagashima, K.

    2010-11-01

    There are several advantages by applying a high-temperature superconducting wire to an on-board superconducting magnet for the maglev train. At first, an increase of thermal capacity of superconducting coils contributes a stability of the superconducting state of the coils. In addition, a reliability of superconducting magnet improves by simplification of the magnet structure. And the weight of the superconducting magnet and the energy consumption of the on-board cryocooler will decrease. Therefore, we examined the possibility on application of the 2G wire with a high critical current density in a high magnetic field. We performed numerical analysis regarding the weight of a superconducting magnet and the energy consumption of an on-board cryocooler in consideration of the characteristics of the 2G wire. Furthermore, we have carried out the Ic measurement for the commercial 2G wires under various experimental conditions such as temperature, magnetic field strength and angle. We also performed the trial manufacture and evaluation of Ic characteristics for the small race track-shaped superconducting coil.

  4. Preliminary study of HTS magnet using 2G wires for maglev train

    NASA Astrophysics Data System (ADS)

    Ogata, Masafumi; Miyazaki, Yoshiki; Hasegawa, Hitoshi; Sasakawa, Takashi; Nagashima, Ken

    2010-06-01

    There are several advantages by applying a high temperature superconducting wire to an on-board superconducting magnet for the maglev train. At first, an increase of thermal capacity of superconducting coils contributes a stability of the superconducting state of the coils. In addition, a reliability of superconducting magnet improves by simplification of the magnet structure. And the weight of the superconducting magnet and the energy consumption of the on-board cryocooler will decrease. Therefore, we examined the possibility on application of the 2G wire with a high critical current density in a high magnetic field. We performed numerical analysis regarding the weight of a superconducting magnet and the energy consumption of an on-board cryocooler in consideration of the characteristics of the 2G wire. Furthermore, we have carried out the Ic measurement for the commercial 2G wires under various experimental conditions such as temperature, magnetic field strength and angle. We also performed the trial manufacture and evaluation of Ic characteristics for the small race track-shaped superconducting coil.

  5. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    NASA Astrophysics Data System (ADS)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  6. Transport ac losses of a second-generation HTS tape with a ferromagnetic substrate and conducting stabilizer

    NASA Astrophysics Data System (ADS)

    Li, Shuo; Chen, Du-Xing; Fang, Jin

    2015-12-01

    The current-voltage curve and transport ac loss of a second-generation HTS tape with a ferromagnetic NiW substrate and brass stabilizer are measured. It is found that the ac loss is up to two orders of magnitude larger than what is expected by the power-law E(J) determined by the current-voltage curve and increases with increasing frequency. Modeling results show that the overly large ac loss is contributed by the ac loss in the HTS strip enhanced by the NiW substrate and the magnetic hysteresis loss in the substrate, and the frequency-dependent loss occurs in the brass layer covering the substrate but not in the ferromagnetic substrate itself as assumed previously. The ac loss in the brass layer is associated with transport currents but not eddy currents, and it has some features similar to ordinary eddy-current loss with significant differences.

  7. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  8. Uniform trapped fields produced by stacks of HTS coated conductor tape

    NASA Astrophysics Data System (ADS)

    Mitchell-Williams, T. B.; Baskys, A.; Hopkins, S. C.; Kalitka, V.; Molodyk, A.; Glowacki, B. A.; Patel, A.

    2016-08-01

    The trapped magnetic field profile of stacks of GdBa2Cu3O7-x superconducting tape was investigated. Angled stacks of superconducting tape were magnetized and found to produce very uniform trapped field profiles. The angled stacks were made of 12 mm × 24 mm solder coated tape pieces and were bonded together following a brief consolidation heat treatment. Layering multiple stacks together and adding a ferromagnetic plate beneath the samples were both found to enhance the magnitude and uniformity of the trapped field profiles. Stationary and time-dependent critical state finite element models were also developed to complement the experimental results and investigate the magnetization process. The size and shapes possible with the angled stacks make them attractive for applications requiring uniform magnetic fields over larger areas than can be achieved with existing bulk rings or tape annuli.

  9. Uniform trapped fields produced by stacks of HTS coated conductor tape

    NASA Astrophysics Data System (ADS)

    Mitchell-Williams, T. B.; Baskys, A.; Hopkins, S. C.; Kalitka, V.; Molodyk, A.; Glowacki, B. A.; Patel, A.

    2016-08-01

    The trapped magnetic field profile of stacks of GdBa2Cu3O7‑x superconducting tape was investigated. Angled stacks of superconducting tape were magnetized and found to produce very uniform trapped field profiles. The angled stacks were made of 12 mm × 24 mm solder coated tape pieces and were bonded together following a brief consolidation heat treatment. Layering multiple stacks together and adding a ferromagnetic plate beneath the samples were both found to enhance the magnitude and uniformity of the trapped field profiles. Stationary and time-dependent critical state finite element models were also developed to complement the experimental results and investigate the magnetization process. The size and shapes possible with the angled stacks make them attractive for applications requiring uniform magnetic fields over larger areas than can be achieved with existing bulk rings or tape annuli.

  10. Preparation of biaxially cube textured Cu substrate tapes for HTS coated conductor applications

    NASA Astrophysics Data System (ADS)

    Piñol, S.; Díaz, J.; Segarra, M.; Espiell, F.

    2001-01-01

    Cube textured copper tapes have been prepared as possible substrates for deposition of high critical current density YBCO films with intermediate metallic or ceramic biaxially textured buffer layers. The cube texture was promoted by recrystallization after cold rolling. The deformation degree, the effect of deformation reduction at each pass and the influence of annealing temperature on the recrystallization process has been studied. Different parameters have been optimized in order to obtain the sharpest cube texture {100}<001>. The full width half-maximum mean values (FWHM) of the grains out-of-plane measured from rocking curves in the parallel and perpendicular directions to the rolling are 10° and 14°, respectively, while the in-plane FWHM obtained from the pole figures is 10°.

  11. The effect of temperature on pinning mechanisms in HTS composites

    NASA Astrophysics Data System (ADS)

    Sotnikova, A. P.; Rudnev, I. A.

    2016-09-01

    Pinning mechanism in samples of second generation tapes (2G) of high-temperature superconductors (HTS) was studied The critical current and the pinning force were calculated from the magnetization curves measured in the temperature range of 4.2 - 77 K in magnetic fields up to 14 Tesla using vibration sample magnetometer. To determine the pinning mechanism the dependences of pinning force on magnetic field were constructed according to the Dew-Hughes model and Kramer's rule. The obtained dependences revealed a significant influence of the temperature on effectiveness of different types of pinning. At low temperatures the 2G HTS tapes of different manufacturers demonstrated an equal efficiency of the pinning centers but with temperature increase the differences in pinning mechanisms as well as in properties and effectiveness of the pinning centers become obvious. The influence of the pinning mechanism on the energy losses in HTS tapes was shown.

  12. Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

    NASA Astrophysics Data System (ADS)

    Tomita, M.; Suzuki, K.; Fukumoto, Y.; Ishihara, A.; Akasaka, T.; Kobayashi, Y.; Maeda, A.; Takayasu, M.

    2015-12-01

    A 2 m length Twisted Stacked-Tape Cable (TSTC) conductor which was fabricated by 32-YBCO-tapes (4 mm width) with a 200 mm twist pitch was investigated at various temperatures near 77 K in subcooled- and pressurized-liquid nitrogen. The critical current of the TSTC cable which was 1.45 kA at 77 K measured from 64 K to 85 K by controlling the equilibrium vapor pressure of nitrogen bath and were varied from 3.65 kA at 64 K to 0.42 kA at 85 K. The temperature dependence of cables’ critical current agrees with that of the 4 mm width YBCO tape. These results are encouraging for applications of a compact Twisted Stacked-Tape Cable application in railway systems.

  13. Study of HTS Wires at High Magnetic Fields

    SciTech Connect

    Turrioni, D.; Barzi, E.; Lamm, M.J.; Yamada, R.; Zlobin, A.V.; Kikuchi, A.; /Fermilab

    2009-01-01

    Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

  14. Development of the Current Bypassing Methods into the Transverse Direction in Non-insulation HTS Coils

    NASA Astrophysics Data System (ADS)

    Tanaka, K.; Kim, S. B.; Ikoma, H.; Kanemoto, D.

    In the case of motors and generators, the benefits of using high temperature superconducting (HTS) coils can be represented by the reduction of 50% in both losses and sizes compared to conventional machines. However, it is hard to establish quench detection and protection devices for the HTS coils applied to the rotors of motors and generators. So, the stability of the coils is lower than for the quiescent coils applied to NMR, MRI and so on. Therefore, it is important to improve the self-protection ability of HTS coils. We have studied the methods to improve the self-protection ability of HTS coils by removing the layer-to-layer insulation and inserting metal tape instead of the electrical insulation. The operating current in the non-insulated HTS coil was bypassed into the transverse direction by the generated normal region because of their electrical contact among the winding. In this study, we examined the method to control the current bypassing on layer-to-layer for controlling the inductance of the non-insulated HTS coil. The current bypassing properties on non-insulated HTS coil wound with 2G wires will be discussed.

  15. Experimental Manufacture and Performance Evaluation of Linear Switched Reluctance Motor with HTS Excitation Windings

    NASA Astrophysics Data System (ADS)

    Hirayama, Tadashi; Oto, Satoshi; Higashijima, Atsushi; Kawabata, Shuma

    This paper presents an experimental manufacture and performance evaluation of prototype linear switched reluctance motor with HTS excitation windings (HTS-LSRM). The Ag-alloy sheathed Bi-2223 tapes are used for HTS coils. We first present a structure of the prototype HTS-LSRM. Next, current-carrying properties of the HTS coils are measured. Furthermore, current and voltage waveforms are measured and we evaluation a control performance of the current and voltage.

  16. Study on Recovery Performance of High Tc Superconducting Tapes for Resistive Type Superconducting Fault Current Limiter Applications

    NASA Astrophysics Data System (ADS)

    kar, Soumen; Kulkarni, Sandeep; Dixit, Manglesh; Singh, Kuwar Pal; Gupta, Alok; Balasubramanyam, P. V.; Sarangi, S. K.; Rao, V. V.

    Recent advances in reliable production of long length high temperature superconducting (HTS) tapes have resulted in commercial application of superconducting fault current limiters (SFCLs) in electrical utility networks. SFCL gives excellent technical performance when compared to conventional fault current limiters. The fast self-recovery from normal state to superconducting state immediately after the fault removal is an essential criterion for resistive type SFCL operation. In this paper, results on AC over-current testing of 1st generation (1G) Bi2223 tapes and 2nd generation (2G) YBCO coated conductors operating at 77 K are reported. From these results, the recovery time is estimated for different available HTS tapes in the market. The current limiting tests have also been performed to study the effective current limitation. Further, the recovery characteristics after the current limitation are quantitatively discussed for repetitive faults for different time intervals in the range of 100 ms to few seconds.

  17. Development of REBCO HTS Power Cables

    NASA Astrophysics Data System (ADS)

    Maruyama, O.; Ohkuma, T.; Masuda, T.; Ohya, M.; Mukoyama, S.; Yagi, M.; Saitoh, T.; Aoki, N.; Amemiya, N.; Ishiyama, A.; Hayakawa, N.

    A Japanese national project, called "Materials & Power applications of Coated Conductors (M-PACC)", started in FY2008. In this project, we are developing 66 kV/5 kA large current high temperature superconducting (HTS) cable and 275 kV/3 kA high voltage HTS cable using REBCO tapes. These HTS cables are expected as a compact size with large capacity and low loss power transmission. We have examined AC loss, thermal characteristics of the cables under over-current, the optimum cable design and so on. After the design studies and elemental tests are completed, long cable systems will be built for verification purposes. This paper described the overview and current status of these HTS cables development in the M-PACC project. (PACS: 84.71.Fk)

  18. Study on Thrust Improvement and Ripple Suppression of HTS Linear Switched Reluctance Motor with Coreless HTS Excitation Windings

    NASA Astrophysics Data System (ADS)

    Oto, Satoshi; Hirayama, Tadashi; Kawabata, Shuma

    This paper describes a linear switched reluctance motor (LSRM) in which HTS tapes are used for coreless excitation windings in order to reduce the thrust ripple and normal force. This LSRM consists of a mover with saliency structure, coreless HTS coils and a stator back yoke. In this paper, we first describe the operating principle of the HTS-LSRM. Next, we calculate performances of the HTS-LSRM using 3-D FEM analysis. The effects of the motor structure on the thrust characteristic and normal force characteristics are clarified from the numerical results. Furthermore, we investigate the motor structure for thrust improvement, thrust ripple and normal force reduction.

  19. Modular test facility for HTS insert coils

    SciTech Connect

    Lombardo, V; Bartalesi, A.; Barzi, E.; Lamm, M.; Turrioni, D.; Zlobin, A.V.; /Fermilab

    2009-10-01

    The final beam cooling stages of a Muon Collider may require DC solenoid magnets with magnetic fields in the range of 40-50 T. In this paper we will present a modular test facility developed for the purpose of investigating very high field levels with available 2G HTS superconducting materials. Performance of available conductors is presented, together with magnetic calculations and evaluation of Lorentz forces distribution on the HTS coils. Finally a test of a double pancake coil is presented.

  20. Designing HTS coils for magnetic circuits

    SciTech Connect

    Jenkins, R.G.; Jones, H.; Goodall, R.M.

    1996-07-01

    The authors discuss some of the main considerations involved in the design of HTS coils to operate in liquid nitrogen and provide ampere-turns for magnetic circuits in general, and then in particular for a small-scale electromagnetic (i.e, attractive) maglev demonstrator. The most important factor affecting design is the sensitive and strongly anisotropic dependence of HTS tape`s critical current on magnetic field. Any successful design must limit the field in the windings, especially components perpendicular to the tape`s surface (radial components in the case of solenoids), to acceptably low levels such that local critical currents nowhere fall below the operating current. This factor is relevant to the construction of HTS coils for all applications. A second important factor is that the presence of an iron magnetic circuit can greatly alter the flux distribution within the coils from that found when they are in free space. FE modelling has been used to calculate accurate field profiles in proposed designs for comparison with short sample I{sub c}(B) data. They present a design for a maglev demonstrator, illustrating how some of the problems, in particular the reduction of radial field components, may be addressed, and describe its predicted performance.

  1. Miniaturized HTS technologies - uHTS.

    PubMed

    Wölcke, J; Ullmann, D

    2001-06-01

    The transition from slow, manual, low-throughput screening to industrialized robotic ultra-high throughput screening (uHTS) in the past few years has made it possible to screen hundreds of thousands of chemical entities against a biological target in a short time-frame. The need to minimize the cost of screening has been addressed primarily by reducing the volume of sample to be screened. This, in turn, has resulted in the miniaturization of HTS technology as a whole. Miniaturization requires new technologies and strategies for compound handling, assay development, assay adaptation, liquid handling and automation in addition to refinement of the technologies used for detection systems and data management. This review summarizes current trends in the field of uHTS and illustrates the technological developments that are necessary to enable the routine application of miniaturized uHTS systems within an industrial environment.

  2. Reflective HTS switch

    DOEpatents

    Martens, Jon S.; Hietala, Vincent M.; Hohenwarter, Gert K. G.

    1994-01-01

    A HTS switch includes a HTS conductor for providing a superconducting path for an electrical signal and an serpentine wire actuator for controllably heating a portion of the conductor sufficiently to cause that portion to have normal, and not superconducting, resistivity. Mass of the portion is reduced to decrease switching time.

  3. Reflective HTS switch

    DOEpatents

    Martens, J.S.; Hietala, V.M.; Hohenwarter, G.K.G.

    1994-09-27

    A HTS (High Temperature Superconductor) switch includes a HTS conductor for providing a superconducting path for an electrical signal and an serpentine wire actuator for controllably heating a portion of the conductor sufficiently to cause that portion to have normal, and not superconducting, resistivity. Mass of the portion is reduced to decrease switching time. 6 figs.

  4. An Analytical Technique to Elucidate Field Impurities From Manufacturing Uncertainties of an Double Pancake Type HTS Insert for High Field LTS/HTS NMR Magnets

    PubMed Central

    Hahn, Seung-yong; Ahn, Min Cheol; Bobrov, Emanuel Saul; Bascuñán, Juan; Iwasa, Yukikazu

    2010-01-01

    This paper addresses adverse effects of dimensional uncertainties of an HTS insert assembled with double-pancake coils on spatial field homogeneity. Each DP coil was wound with Bi2223 tapes having dimensional tolerances larger than one order of magnitude of those accepted for LTS wires used in conventional NMR magnets. The paper presents: 1) dimensional variations measured in two LTS/HTS NMR magnets, 350 MHz (LH350) and 700 MHz (LH700), both built and operated at the Francis Bitter Magnet Laboratory; and 2) an analytical technique and its application to elucidate the field impurities measured with the two LTS/HTS magnets. Field impurities computed with the analytical model and those measured with the two LTS/HTS magnets agree quite well, demonstrating that this analytical technique is applicable to design a DP-assembled HTS insert with an improved field homogeneity for a high-field LTS/HTS NMR magnet. PMID:20407595

  5. An Analytical Technique to Elucidate Field Impurities From Manufacturing Uncertainties of an Double Pancake Type HTS Insert for High Field LTS/HTS NMR Magnets.

    PubMed

    Hahn, Seung-Yong; Ahn, Min Cheol; Bobrov, Emanuel Saul; Bascuñán, Juan; Iwasa, Yukikazu

    2009-06-01

    This paper addresses adverse effects of dimensional uncertainties of an HTS insert assembled with double-pancake coils on spatial field homogeneity. Each DP coil was wound with Bi2223 tapes having dimensional tolerances larger than one order of magnitude of those accepted for LTS wires used in conventional NMR magnets. The paper presents: 1) dimensional variations measured in two LTS/HTS NMR magnets, 350 MHz (LH350) and 700 MHz (LH700), both built and operated at the Francis Bitter Magnet Laboratory; and 2) an analytical technique and its application to elucidate the field impurities measured with the two LTS/HTS magnets. Field impurities computed with the analytical model and those measured with the two LTS/HTS magnets agree quite well, demonstrating that this analytical technique is applicable to design a DP-assembled HTS insert with an improved field homogeneity for a high-field LTS/HTS NMR magnet.

  6. TEST RESULTS OF HTS COILS AND AN R AND D MAGNET FOR RIA.

    SciTech Connect

    GUPTA, R.; ANERELLA, M.; HARRISON, M.; SCHMALZLE, J.; SAMPSON, W.; ZELLER, A.

    2005-05-16

    This paper presents the successful construction and test results of a magnetic mirror model for the Rare Isotope Accelerator (RIA) that is based on High Temperature Superconductors (HTS). In addition, the performance of thirteen coils (each made with {approx}220 meters of commercially available HTS tape) is also presented. The proposed HTS magnet is a crucial part of the R&D for the Fragment Separator region where the magnets are subjected to several orders of magnitude more radiation and energy deposition than typical beam line and accelerator magnets receive during their entire lifetime. A preliminary design of an HTS dipole magnet for the Fragment Separator region is also presented.

  7. Recent advances of HTS power application research at IEE

    NASA Astrophysics Data System (ADS)

    Ma, Yanwei; Lin, Liangzhen; Xiao, Liye

    2006-06-01

    Recent advances of high temperature superconductors (HTS) for power applications in the Institute of Electrical Engineering (IEE), Chinese academy of Sciences are presented. A 75 meter, 10.5 kV/1.5 kA three phase HTS transmission cable has been successfully demonstrated in a live distribution grid in northwest China. A 10.5 kV/200A bridge-type fault current limiter (FCL) prototype based on Bi-2223 tapes is being tested in a Hunan power plant since August 2005. A 400V/16V/26 kVA three phase HTS transformer was designed, built and tested, and the on site system installation of a 10.5 kV/400V/630 kVA HTS transformer will be finished at Tebian Electric Ltd. soon. In addition, the progress of design and test of SMES is also given.

  8. RADIATION RESISTANT HTS QUADRUPOLES FOR RIA.

    SciTech Connect

    GUPTA,R.; ANERELLA,M.; HARRISON,M.; ET AL.

    2004-10-03

    Extremely high radiation, levels with accumulated doses comparable to those in nuclear reactors than in accelerators, and very high heat loads ({approx}15 kw) make the quadrupole magnets in the fragment separator one of the most challenging elements of the proposed Rare Isotope Accelerator (RIA). Removing large heat loads, protecting the superconducting coils against quenching, the long term survivability of magnet components, and in particular, insulation that can retain its functionality in such a harsh environment, are the major challenges associated with such magnets. A magnet design based on commercially available high temperature superconductor (HTS) and stainless steel tape insulation has been developed. HTS will efficiently remove these large heat loads and stainless steel can tolerate these large radiation doses. Construction of a model magnet has been started with several coils already built and tested. This paper presents the basic magnet design, results of the coil tests, the status and the future plans. In addition, preliminary results of radiation calculations are also presented.

  9. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    NASA Astrophysics Data System (ADS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-12-01

    HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate.

  10. The method of measuring the temperature dependence of the critical current of the HTS-2

    NASA Astrophysics Data System (ADS)

    Yashkin, D. S.; Krasnoperov, E. P.; Brazhnik, P. A.; Kruglov, V. S.

    2016-09-01

    A new method of measurement of Ic(T) dependence for the HTS-2 tape is realized. In this method, the metal substrate of the tape is used as both a heater and a thermometer. Index n(T) was calculated from the measured current-voltage characteristics (CVC). For the tape manufactured by SuperPower Inc. the data of n-index temperature dependence in the range from 77 K up to 90 K are presented.

  11. Review of activities in USA on HTS materials

    SciTech Connect

    Peterson, D.E.

    1995-02-01

    Rapid progress in attaining practical applications of High Temperature Superconductors (HTS) has been made since the discovery of these new materials. Many critical parameters influencing HTS powder synthesis and wire processing have been identified through a combination of fundamental exploration and applied research. The complexity of these novel materials with regard to phase behavior and physical properties has become evident as a result of these careful studies. Achieving optimal mechanical and superconducting properties in wires and tapes will require further understanding and synergy among several different technical disciplines. Highlights of efforts towards producing practical superconductors for electric power applications based on rare earth-, bismuth-, and thallium-based systems are reviewed.

  12. Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet

    PubMed Central

    Ahn, Min Cheol; Yagai, Tsuyoshi; Hahn, Seungyong; Ando, Ryuya; Bascuñán, Juan; Iwasa, Yukikazu

    2010-01-01

    This paper presents experimental and simulation results of a screening current induced magnetic field (SCF) in a high temperature superconductor (HTS) insert that constitutes a low-/high-temperature superconductor (LTS/HTS) NMR magnet. In this experiment, the HTS insert, a stack of 50 double-pancake coils, each wound with Bi2223 tape, was operated at 77 K. A screening current was induced in the HTS insert by three magnetic field sources: 1) a self field from the HTS insert; 2) an external field from a 5-T background magnet; and 3) combinations of 1) and 2). For each field excitation, which induced an SCF, its axial field distribution and temporal variations were measured and compared with simulation results based on the critical state model. Agreement on field profile between experiment and simulation is satisfactory but more work is needed to make the simulation useful for designing shim coils that will cancel the SCF. PMID:20401187

  13. Reduction of Thermal Loss in HTS Windings by Using Magnetic Flux Deflection

    NASA Astrophysics Data System (ADS)

    Tsuzuki, K.; Miki, M.; Felder, B.; Koshiba, Y.; Izumi, M.; Umemoto, K.; Aizawa, K.; Yanamoto, T.

    Efforts on the generation of intensified magnetic flux have been made for the optimized shape of HTS winding applications. This contributes to the high efficiency of the rotating machines using HTS windings. Heat generation from the HTS windings requires to be suppressed as much as possible, when those coils are under operation with either direct or alternative currents. Presently, the reduction of such thermal loss generated by the applied currents on the HTS coils is reported with a magnetic flux deflection system. The HTS coils are fixed together with flattened magnetic materials to realize a kind of redirection of the flux pathway. Eventually, the magnetic flux density perpendicular to the tape surface (equivalent to the a-b plane) of the HTS tape materials is reduced to the proximity of the HTS coil. To verify the new geometry of the surroundings of the HTS coils with magnetic materials, a comparative study of the DC coil voltage was done for different applied currents in prototype field-pole coils of a ship propulsion motor.

  14. Impact of Inhomogeneities in HTS Coated Conductors for Resistive FCLs

    NASA Astrophysics Data System (ADS)

    Colangelo, Daniele; Memiaghe, Steeve; Lacroix, Christian; Sirois, Frédéric; Dutoit, Bertrand

    Several issues remain to be addressed for the commercial development of ResistiveFault Current Limiters based on superconducting technologies (RFCL). In particular, the inhomogeneity of high temperature superconducting coated conductors (HTS-CC) combined with the diffculty to predict RFCLs behaviour when interfaced with the existing electrical grid represents an important bottleneck that limits their competitiveness on the electrical market. In order to study the influence of the local inhomogeneity of the HTS tape on the global effective performance of an RFCL, a modular equivalent circuit model has been developed using SimPowerSystemsTM. The model implements an inhomogeneity distribution based on statistical data and takes into account the thermal conduction between different zones of the HTS-CC. It has been calibrated with experimental measurements and finite element simulations. The model can be used to study various scenarios common to power systems, such as transformer in-rush currents, motor starts, etc.

  15. Fabrication of Yb-123 Tapes

    SciTech Connect

    Athur, S.; Balachandran, U.; Salama, K.

    2000-11-15

    While Bi-2223 tapes have been the workhorses of the superconductor industry, their poor performance in applied magnetic fields restrict their use to below 30 K. Melt-processing of Ag-clad Yb-123 PIT tapes offers a simple and scalable technique for fabricating long-length HTS conductors capable of being used at 77 K. Under reduced oxygen partial pressure, the peritectic temperature of Yb-123 is below the melting point of Ag, and this facilitates the adaptation of melt-texturing methods for fabricating these tapes. The effect of melt-processing temperature on current density was also explored; a temperature of 965 C yielded optimal critical current values. The critical current density achieved at 4.2 K was 20,000 A/cm{sup 2}, corresponding to a critical current of 52 A. Based on the above results, an optimal processing zone for melt-processing of Ag-clad Yb-123 tapes was determined. These results hold promise for melt-processing of Ag-clad Yb-123 tapes as an alternative to Bi-2223 PIT technology.

  16. Test results of HTS magnet for SMES application

    NASA Astrophysics Data System (ADS)

    Kozak, J.; Majka, M.; Jaroszynski, L.; Janowski, T.; Kozak, S.; Kondratowicz – Kucewicz, B.; Wojtasiewicz, G.

    2010-06-01

    The magnet for a superconducting magnetic energy storage system (SMES) conducting cooled by SRDK-408 cryocooler is described in this paper. The superconducting magnet consists of 7 double-pancake coils made of Bi-2223 HTS tape with the inner and outer diameters 210 mm, 315 mm respectively and height of 191 mm. The inductance of the magnet is approximately 1 H. In this paper we report the design improvements and the measurement results taken at the cooling of the magnet.

  17. n value and Jc distribution dependence of AC transport current losses in HTS conductors

    NASA Astrophysics Data System (ADS)

    Ogawa, Jun; Sawai, Yusuke; Nakayama, Haruki; Tsukamoto, Osami; Miyagi, Daisuke

    2004-01-01

    Compared with LTS materials, HTS materials have some peculiarities affecting AC loss characteristics of the conductors. We measured the AC transport current losses in YBCO thin film coated conductors and a Bi2223/Ag sheathed tape. Comparing the measured data with analytical calculations, the dependence of the AC transport current losses on the n value and critical current density distributions are studied. It is shown that, considering the n values and Jc distributions, the peculiarities in the HTS materials can be taken into consideration and the transport current losses in HTS conductors can be calculated by the same analytical method used for LTS.

  18. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  19. Numerical models for ac loss calculation in large-scale applications of HTS coated conductors

    NASA Astrophysics Data System (ADS)

    Quéval, Loïc; Zermeño, Víctor M. R.; Grilli, Francesco

    2016-02-01

    Numerical models are powerful tools to predict the electromagnetic behavior of superconductors. In recent years, a variety of models have been successfully developed to simulate high-temperature-superconducting (HTS) coated conductor tapes. While the models work well for the simulation of individual tapes or relatively small assemblies, their direct applicability to devices involving hundreds or thousands of tapes, e.g., coils used in electrical machines, is questionable. Indeed, the simulation time and memory requirement can quickly become prohibitive. In this paper, we develop and compare two different models for simulating realistic HTS devices composed of a large number of tapes: (1) the homogenized model simulates the coil using an equivalent anisotropic homogeneous bulk with specifically developed current constraints to account for the fact that each turn carries the same current; (2) the multi-scale model parallelizes and reduces the computational problem by simulating only several individual tapes at significant positions of the coil’s cross-section using appropriate boundary conditions to account for the field generated by the neighboring turns. Both methods are used to simulate a coil made of 2000 tapes, and compared against the widely used H-formulation finite-element model that includes all the tapes. Both approaches allow faster simulations of large number of HTS tapes by 1-3 orders of magnitudes, while maintaining good accuracy of the results. Both models can therefore be used to design and optimize large-scale HTS devices. This study provides key advancement with respect to previous versions of both models. The homogenized model is extended from simple stacks to large arrays of tapes. For the multi-scale model, the importance of the choice of the current distribution used to generate the background field is underlined; the error in ac loss estimation resulting from the most obvious choice of starting from a uniform current distribution is revealed.

  20. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  1. Interfacial bonding enhancement of reel-to-reel selective electrodeposition of copper stabilizer on a multifilamentary second-generation high-temperature superconductor tape

    NASA Astrophysics Data System (ADS)

    Cai, Xinwei; Li, Wei; Bose, Anima; Selvamanickam, Venkat

    2016-10-01

    A reel-to-reel copper selective electrodeposition process over a multifilamentary second-generation high-temperature superconductor (2G-HTS) has been demonstrated in our previous work. If the interfacial bonding between the deposited copper layer and the underlying silver overlayer is weak, it might lead to delamination in applications including magnets, motors and generators. In this study, two approaches have been used to improve the copper-silver bonding without the degradation of superconductor performance. The first approach is acidifying the electrolyte by adding sulfuric acid, by which the kinetics of copper electrodeposition is enhanced, resulting in finer microstructure at the copper-silver interface and thus, improved interfacial bonding strength. The second approach consists of blocking the electrolyte outflow at the entrance of the reel-to-reel electroplating cell, by which the occurrence of large copper seeds on the tape caused by the heavy turbulence flow is effectively prevented. With these two improvements together deployed in the process, the peeling strength between the copper and silver layers of the 2G-HTS tape has been improved from <0.3 N to >2 N in 90° peeling and from <0.5 N to >3.0 N in 180° peeling, without any degradation on the superconducting performance.

  2. A high temperature superconductor tape RF receiver coil for a low field magnetic resonance imaging system

    NASA Astrophysics Data System (ADS)

    Cheng, M. C.; Yan, B. P.; Lee, K. H.; Ma, Q. Y.; Yang, E. S.

    2005-08-01

    High temperature superconductor (HTS) thin films have been applied in making a low loss RF receiver coil for improving magnetic resonance imaging image quality. However, the application of these coils is severely limited by their limited field of view (FOV). Stringent fabrication environment requirements and high cost are further limitations. In this paper, we propose a simpler method for designing and fabricating HTS coils. Using industrial silver alloy sheathed Bi(2-x)PbxSr2Ca2Cu3O10 (Bi-2223) HTS tapes, a five-inch single-turn HTS solenoid coil has been developed, and human wrist images have been acquired with this coil. The HTS tape coil has demonstrated an enhanced FOV over a six-inch YBCO thin film surface coil at 77 K with comparable signal-to-noise ratio.

  3. DEVELOPMENT OF HTS CONDUCTORS FOR ELECTRIC POWER APPLICATIONS

    SciTech Connect

    Goyal, A.; Rupich, M.

    2012-10-23

    Second generation (2G) technologies to fabricate high-performance superconducting wires developed at the Oak Ridge National Laboratory (ORNL) were transferred to American Superconductor via this CRADA. In addition, co-development of technologies for over a decade was done to enable fabrication of commercial high-temperature superconducting (HTS) wires with high performance. The massive success of this CRADA has allowed American Superconductor Corporation (AMSC) to become a global leader in the fabrication of HTS wire and the technology is fully based on the Rolling Assisted Biaxially Textured Substrates (RABiTS) technology invented and developed at ORNL.

  4. Design, fabrication and evaluation of a conduction cooled HTS magnet for SMES

    NASA Astrophysics Data System (ADS)

    Bae, J. H.; Kim, S. H.; Kim, H. J.; Sohn, M. H.; Seong, K. C.; Kim, H. M.

    2009-10-01

    This paper describes design, fabrication, and evaluation of the conduction cooled high temperature superconducting (HTS) magnet for superconducting magnetic energy storage (SMES). The HTS magnet is composed of 22 of double pancake coils made of 4-ply conductors that stacked two Bi-2223 multi-filamentary tapes with the reinforced brass tape. Each double pancake coil consists of two solenoid coils with an inner diameter of 500 mm, an outer diameter of 691 mm, and a height of 10 mm. The aluminum plates of 3 mm thickness were arranged between double pancake coils for the cooling of the heat due to the power dissipation in the coil. The magnet was cooled down to 5.6 K with two stage Gifford McMahon (GM) cryocoolers. The maximum temperature at the HTS magnet in discharging mode rose as the charging current increased. 1 MJ of magnetic energy was successfully stored in the HTS magnet when the charging current reached 360A without quench. In this paper, thermal and electromagnetic behaviors on the conduction cooled HTS magnet for SMES are presented and these results will be utilized in the optimal design and the stability evaluation for conduction cooled HTS magnets.

  5. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  6. Note: Effective measurement of retained I(c) in evaluating electromechanical properties of high temperature superconductor tapes by the voltage tap clipping technique.

    PubMed

    Dedicatoria, Marlon J; Bautista, Zhierwinjay; Shin, Hyung-Seop; Sim, Kideok

    2015-08-01

    In this note, the effectiveness of voltage tap clipping technique was assessed in evaluating the electromechanical properties of high temperature superconductor (HTS) tapes in the aspect of practical device applications. In the four-probe transport I(c) measurement, instead of directly soldering the voltage lead wires onto the HTS samples, they were tapped to the sample by either just clipping or soldering them to the clips. This technique facilitated the simultaneous and repeated retained I(c) measurement test for multiple samples. Finally, the critical double bending diameter of HTS tapes and the electrical properties of jointed and striated coated conductor tapes could be easily determined.

  7. Multi-channel Data Acquisition System for a 500 m DC HTS Power Cable in Ishikari

    NASA Astrophysics Data System (ADS)

    Ivanov, Yury V.; Chikumoto, Noriko; Watanabe, Hirofumi; Takano, Hirohisa; Inoue, Noriyuki; Yamaguchi, Satarou

    Reduction of heat penetrating into the cryogenic region is the important method of optimization of superconducting devices. In the cases of short-range power transmission lines and compact HTS devices like magnets, the heat leakage through current leads is relatively large. In order to decrease this contribution, current leads equipped with Peltier elements can be used. The mentioned technology is being actively developed in the Chubu University. Commercial samples of Peltier current leads are installed at the terminals of 500-meter DC HTS cable in Ishikari (Hokkaido). This cable is designed for 5 kA. The inner conducting layer consists of 37 DI-BSCCO HTS tapes from Sumitomo Electric Industries, Ltd. with a critical current of 180 A; and the outer one consists of 35 tapes of the same type. Each end of the cable's tape is connected to the individual Peltier current lead. Accordingly, each of the two terminals is equipped with 72 Peltier current leads, 144 pieces in total. In order to examine behavior of the current leads in detail, each piece is supplied with two thermocouples; there are also voltage taps on feedthrough and on HTS tape end. In addition, current through Peltier current lead can be measured by means of individual current transformer. The hardware part of the data acquisition system includes four Keithley 3706A multimeters equipped with 60-channel model 3724 FET multiplexer cards. Therefore, 144 data blocks are formed. Furthermore, there are 72 measurements of a voltage drop across HTS tape. Sampling period is set to be 3 s. The program part of the data acquisition system was written using LabVIEW software solution (National Instruments Corp.).

  8. Development of Prototype HTS Components for Magnetic Suspension Applications

    NASA Technical Reports Server (NTRS)

    Haldar, P.; Hoehn, J., Jr.; Selvamanickam, V.; Farrell, R. A.; Balachandran, U.; Iyer, A. N.; Peterson, E.; Salazar, K.

    1996-01-01

    We have concentrated on developing prototype lengths of bismuth and thallium based silver sheathed superconductors by the powder-in-tube approach to fabricate high temperature superconducting (HTS) components for magnetic suspension applications. Long lengths of mono and multi filament tapes are presently being fabricated with critical current densities useful for maglev and many other applications. We have recently demonstrated the prototype manufacture of lengths exceeding 1 km of Bi-2223 multi filament conductor. Long lengths of thallium based multi-filament conductor have also been fabricated with practical levels of critical current density and improved field dependence behavior. Test coils and magnets have been built from these lengths and characterized over a range of temperatures and background fields to determine their performance. Work is in progress to develop, fabricate and test HTS windings that will be suitable for magnetic suspension, levitation and other electric power related applications.

  9. Progress of 275 kV-3 kA YBCO HTS cable

    NASA Astrophysics Data System (ADS)

    Yagi, M.; Mukoyama, S.; Amemiya, N.; Ishiyama, A.; Wang, X.; Aoki, Y.; Saito, T.; Ohkuma, T.; Maruyama, O.

    2011-11-01

    A 275 kV-3 kA high temperature superconducting (HTS) cable has been developed in the Materials & Power Applications of Coated Conductors (M-PACC) project. AC loss reduction of a two-layer HTS conductor was undertaken by removing the edges of YBCO tapes with low critical current density. The HTS conductor using these tapes was fabricated, and low loss of 0.235 W/m at 3 kA rms was achieved. The 275 kV-3 kA cable was designed, and the 2 m model cables were fabricated. This cable had 325 mm 2 copper stranded former inside the HTS conductor and a 310 mm 2 copper shield layer on the HTS shield layer for over-current protection. These cables withstood an over-current of 63.0 kA for 0.6 s, which is the worst situation for 275 kV systems. The partial discharge (PD) and V- t characteristics of a liquid nitrogen (LN 2)/polypropylene (PP) laminated paper composite insulation system have been integrated into the design of the insulation for the 275 kV cable. The results revealed that the PD inception stress (PDIE) did not depend on the insulation thickness, and that lifetime indices of V- t characteristics at PD inception were as high as about 80-100.

  10. French Tape Catalog.

    ERIC Educational Resources Information Center

    Blaney, Robert, Comp.

    This tape catalog is a complete list of all French-related titles appearing in the National Center for Audio Tapes 1974-76 catalog. Wherever possible, each tape is briefly described. Price and ordering information is included. (PMP)

  11. AC Loss Measurements on a 2G YBCO Coil

    SciTech Connect

    Rey, Christopher M; Duckworth, Robert C; Schwenterly, S W

    2011-01-01

    The Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to continue development of HTS power transformers. For compatibility with the existing power grid, a commercially viable HTS transformer will have to operate at high voltages in the range of 138 kV and above, and will have to withstand 550-kV impulse voltages as well. Second-generation (2G) YBCO coated conductors will be required for an economically-competitive design. In order to adequately size the refrigeration system for these transformers, the ac loss of these HTS coils must be characterized. Electrical AC loss measurements were conducted on a prototype high voltage (HV) coil with co-wound stainless steel at 60 Hz in a liquid nitrogen bath using a lock-in amplifier technique. The prototype HV coil consisted of 26 continuous (without splice) single pancake coils concentrically centered on a stainless steel former. For ac loss measurement purposes, voltage tap pairs were soldered across each set of two single pancake coils so that a total of 13 separate voltage measurements could be made across the entire length of the coil. AC loss measurements were taken as a function of ac excitation current. Results show that the loss is primarily concentrated at the ends of the coil where the operating fraction of critical current is the highest and show a distinct difference in current scaling of the losses between low current and high current regimes.

  12. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  13. Novel processing of HTS based conductors

    SciTech Connect

    Ginley, D. S.; Venturini, E. L.; Kwak, J. F.; Baughman, R. J.; Bourcier, R. J.; Mitchell, M. A.; Morosin, B.; Halloran, J. W.; Neal, M. J.; Capone, D. W.

    1990-01-01

    Conductor development is one of the major long term goals in high temperature superconductor research. In this paper we report on two promising processing technologies that have been utilized to produce superconducting HTS conductors. First, melt spun YBa{sub 2}Cu{sub 3}O{sub 7} fibers rapid thermal processed for 1--8 sec at 950 to 1075{degree}C have {Tc}'s to 92 K, J{sub c}'s to 1100 A/cm{sup 2} and the orthorhombic twinned morphology typical for high quality YBa{sub 2}Cu{sub 3}O{sub 7}. A processing matrix of time, temperature and composition for these fibers shows that slightly CuO-rich starting compositions give the best results. Second, silver tube encapsulated wires of Bi{sub 1.7}Pb{sub 0.3}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub 10} have been made by extrusion, wire drawing and cold rolling. The resulting tapes show orientation of the crystallites, zero resistance up to 100K and improved magnetic hysteresis above 50 K. The combination of mechanical reprocessing and extended thermal anneals near 850{degree}C appears to significantly improve these materials. 13 refs., 7 figs.

  14. A 1.3-GHz LTS/HTS NMR Magnet–A Progress Report

    PubMed Central

    Bascuñán, Juan; Hahn, Seungyong; Park, Dong Keun; Iwasa, Yukikazu

    2011-01-01

    In this paper we present details of a 600 MHz HTS insert (H600) double pancake (DP) windings. It will first be operated in the bore of a 500 MHz LTS magnet, achieving a frequency of 1.1 GHz. Upon completion of H600, we will embark on the final phase (Phase 3B) of a 3-Phase program began in 2000: completion of a high resolution 1.3 GHz LTS/HTS magnet. In Phase 3B, the H600 will be coupled to a 700 MHz LTS magnet to achieve the ultimate frequency of 1.3 GHz. The HTS insert is composed of two concentric stacks of double pancakes, one wound with high strength BSCCO-2223 tape, the other with YBCO coated conductor. Details include conductor and coil parameters, winding procedure, DPs mechanical support and integration to the background 500 MHz LTS magnet. Test results of individual DPs in LN2 are also presented. PMID:22081752

  15. Melt processing of Yb-123 tapes

    SciTech Connect

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-02-17

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J{sub c} increased with decrease in pO{sub 2}. The highest I{sub c} obtained was 52 A at 4.2 K.

  16. Parametric study for the cooling of high temperature superconductor (HTS) current leads

    NASA Astrophysics Data System (ADS)

    Lewandowska, Monika; Wesche, Rainer

    2013-01-01

    The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been considered, i.e. (1) cooling with a single flow of gaseous helium and (2) cooling with two flows of gaseous helium. The ideal refrigerator power required to cool the whole HTS CL has been calculated for both cooling scenarios and different values of input parameters and the thermodynamic optimization has been performed for both cooling options. The obtained results indicate that the cooling Option 2 cannot provide significant savings of the refrigerator power, as compared to the Option 1. However, it has been observed that at the same helium inlet temperature the temperature at the warm end of the HTS part, and the resulting number of HTS tapes, can be reduced in the Option 2 with respect to the Option 1.

  17. Striped tape arrays

    NASA Technical Reports Server (NTRS)

    Drapeau, Ann L.; Katz, Randy H.

    1992-01-01

    A growing number of applications require high capacity, high throughput tertiary storage systems. How data striping ideas apply to arrays of magnetic tape drives is investigated. Data striping increases throughput and reduces response time for large accesses to a storage system. Striped magnetic tape systems are particularly appealing because many inexpensive magnetic tape drives have low bandwidth; striping may offer dramatic performance improvements for these systems. There are several important issues in designing striped tape systems: the choice of tape drives and robots, whether to stripe within or between robots, and the choice of the best scheme for distributing data on cartridges. One of the most troublesome problems in striped tape arrays is the synchronization of transfers across tape drives. Another issue is how improved devices will affect the desirability of striping in the future. The results of simulations comparing the performance of striped tape systems to non-striped systems are presented.

  18. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  19. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  20. HTS High Gradient Magnetic Separation system

    SciTech Connect

    Daugherty, M.A.; Coulter, J.Y.; Hults, W.L.

    1996-09-01

    We report on the assembly, characterization and operation of a high temperature superconducting (HTS) magnetic separator. The magnet is made of 624 m of Silver/BSCCO superconducting wire and has overall dimensions of 18 cm OD, 15.5 cm height and 5 cm ID. The HTS current leads are designed to operate with the warm end at 75 K and the cold end cooled by a two stage Gifford-McMahon cryocooler. The upper stage of the cryocooler cools the thermal shield and two heat pipe thermal intercepts. The lower stage of the cryocooler cools the HTS magnet and the bottom end of the HTS current leads. The HTS magnet was initially characterized in liquid cryogens. We report on the current- voltage (I-V) characteristics of the HTS magnet at temperatures ranging from 15 to 40 K. At 40 K the magnet can generate a central field of 2.0 T at a current of 120 A.

  1. Feasibility study for reduction of the screening current induced field in a 2G high temperature superconducting coil

    NASA Astrophysics Data System (ADS)

    Hwang, Y. J.; Jang, J. Y.; Ahn, M. C.; Park, Y. G.; Lee, S. G.

    2016-10-01

    This paper reports the effects of thermal energy on reducing the overshoot of the current sweep cycle method to reduce the screening current-induced field (SCF) in a 2G high temperature superconducting (HTS) coil. A disadvantage of the current sweep cycle method is the necessity for large overshoot in the coil current. For a 2G HTS coil, excessive overshooting of the coil current is undesirable (Yanagisawa et al 2012 AIP Conf. Proc. 1434 1373-8). In an effort to circumvent this overshooting problem, the thermal energy effect was investigated in combination with the current sweep cycle method based on experiments in this study. The experimental results show that greater SCF reduction in the HTS coil was obtained upon increasing thermal energy by heater current.

  2. VLBA: Formatter to Tape

    NASA Astrophysics Data System (ADS)

    Rogers, A. E. E. R.

    Introduction; Why Magnetic Tape?; VLBI Recording Systems; The VLBA Data Format; Longitudinal Format; Transverse Track Format; Data and Non-Data Replacement; Track Width and Track Structure; The VLBA Formatter; Switch Board; Header Control Board; Transport Driver Board; Timing and Control Board; DataBuffer Board; Analysis Board; Magnetic Recording Fundamentals; Recording Losses; Wavelength Response; Head-to-Tape Contact and Tribology; The VLBA Recorder; The Tape Transport; The Headstack; The Headstack Positioner; Control Electronics; Signal Electronics and Eye Pattern; Characteristics and Limitations; Error Rate Versus Bit Density; Tape Thickness Interchange; Head Flying; Overwrite; Tracking Errors; Headlife and Humidity; Thin Tape and Edge Damage by Frictional Heating; Tape Reel and Shipping Canister; Future VLBI Recording Systems; Expansion Paths for the VLBA Formatter; Recorder Improvements; Thinner Tape; Higher Data Rates; Next Generation of Heads; Mark IV; Summary and Conclusions

  3. High Voltage Breakdown, Partial Discharge and Aging in Lapped Tape Insulated Cold Dielectric Model Cables

    NASA Astrophysics Data System (ADS)

    Sauers, I.; James, D. R.; Pace, M. O.; Ellis, A. R.; Muller, A. C.

    2004-06-01

    High temperature superconducting (HTS) power cables generally follow either of two generic designs, cold dielectric and warm dielectric. In the cold dielectric design, lapped tape insulation and liquid nitrogen are used in combination to provide the electrical insulation between the conductor and the ground shield of an HTS cable. Lapped tape insulated model cables have been tested at high voltage, including AC breakdown, negative impulse breakdown, partial discharge, and long term aging under AC stress. Tapes tested include Cryoflex™ (a proprietary tape developed by Southwire) and PPLP® (a commercial semi synthetic tape). Two high voltage cryostats have been built for short and long term aging studies that permit testing of model cables under the combined conditions of high electric stress, cryogenic temperature and elevated pressures up to 15 bar. For the aging studies, a log-log plot of electric stress versus time-to-breakdown has yielded an estimate of cable lifetime. Since aging at cryogenic temperatures is not expected to have a thermal cause, dielectric wear in HTS cables reduces to partial discharge as the primary aging mechanism. Phase and amplitude resolved partial discharge data of model cables in liquid nitrogen will be presented.

  4. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  5. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  6. Experimental Study of Local Micro-forming for Bi-HTS

    SciTech Connect

    Zeng Pan; Lu Yongjin; Lei Liping; Qu Timing; Fang Gang

    2010-06-15

    The Bi-HTS (BSCCO high temperature superconductor) tape now has become the product in an industrial way, which has been available to apply in electric and electron fields. The main way to manufacture Bi-HTS tape is to use the technique of oxide powder in silver tube (OPIT), which involves the multi-step drawing and rolling with plastic deformation, which obviously belongs to a type of the micro-forming in macro-scale processing. There are two main characteristics founded: (a) contact and friction between silver and BSCCO surfaces, (b) interface between two materials. A series of micro-tensile experiments of silver foil with thicknesses of 0.03, 0.06 and 0.1 mm are designed to investigate the behaviors of silver with various scale of sizes. And the surface topography measurements have been carried out to analyze the changes in surface topography. Based upon experiments, some topics are researched which are referred to inhomogeneous, local effect, size effect, grain and micro-structure affecting, surface roughness, long-distance sausage phenomenon. Further the local breakdown of silver by Bi-HTS powder during process is analyzed through failure criterion. The results of this work will bring out an important exploration value to the theory and computation of micro-forming.

  7. Long-term test of the 22.9kV HTS power cable system in LS Cable Ltd

    NASA Astrophysics Data System (ADS)

    Jang, Hyun Man; Lee, Chang Young; Kim, Choon Dong; Kim, Do Hyung; Son Park, In; Ji, Bong Ki; Kim, Dong Wook; Cho, Jeonwook

    2006-06-01

    Since 2001, LS cable Ltd. has been developing the design, manufacturing and evaluation technologies for high temperature superconducting (HTS) power cable system as a member of DAPAS (Dream for Advanced Power system by Applied Superconductivity technology) program in Korea. The 30 m HTS cable system that is rated at 22.9 kV and 1.2 kA giving a rated capacity of 50 MVA had been developed and tested. The cable was designed as a cold dielectric type employing Bi-2223 HTS tapes and polypropylene (PP) laminated paper as the conductor and electrical insulation, respectively. The cable is cooled with sub-cooled liquid nitrogen at temperature from 75 to 77 K. The manufacturing and the installation of the cable system were completed in 2004. Long-term performance test of the cable system has been conducted for six months to verify its electric and mechanical properties in 2005.

  8. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  9. HTS nonlinearities in microwave disk resonators

    NASA Astrophysics Data System (ADS)

    Collado, Carlos; Mateu, Jordi; Shaw, Timothy J.; O'Callaghan, Juan M.

    2002-08-01

    This article describes a procedure for the calculation of the intermodulation behavior of the TM0 1 0 mode in high temperature superconducting (HTS) disk resonators from a description of the local HTS nonlinearities. Successful cross-checks are performed by comparing the theoretical results with experimental measurements and simulations based on the multiport harmonic balance algorithm for a specific model of HTS nonlinearity. The application of this procedure to the determination of nonlinear material parameters from disk resonator measurements is illustrated and compared to theoretical predictions.

  10. Duct Tape Durability Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2004-04-01

    Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

  11. Evaluation of a strengthening and insulation system for high temperature BSCCO-2223 superconducting tape

    SciTech Connect

    King, C.; Mantone, A.; Herd, K.; Laskaris, T.

    1995-12-31

    Recent advances in BSCCO-2223 superconducting tape quality and length have led to demonstration programs for coil performance. The conductors in these coils need to be insulated without damage to the superconducting properties. A paper insulation process developed at the General Electric Company (GE) for low temperature superconducting Nb{sub 3}Sn tape has been modified to provide the same insulation system to high temperature (HTS) superconducting tapes, such as BSCCO-2223. In this paper, we report on the insulation process and its effect on the tape performance. Several long lengths of conductor have been tested, unwound, insulated and retested to examine any degradation issues. Additionally, it is known that HTS materials are inherently weak in relation to the winding and handling stresses in a manufacturing environment. A system to provide mechanical stabilization to Nb{sub 3}Sn tape through a lamination process has been successfully applied to high temperature superconductors as a method to build a strong, windable composite. The system is described and mechanical and electrical properties of the strengthened tapes are discussed.

  12. Development of HTS Magnet for Rotating Gantry

    NASA Astrophysics Data System (ADS)

    Tasaki, Kenji; Koyanagi, Kei; Takayama, S. Shigeki; Ishii, Yusuke; Kurusu, Tsutomu; Amemiya, Naoyuki; Ogitsu, Toru; iwata, Yoshiyuki; Noda, Koji

    The effectiveness of heavy-ion radiotherapy for cancer treatment has been recognized by medical experts and the public. However, due to the large size of the equipment, this therapy has not been widely adopted. In particular, the rotating gantries used to irradiate patients with the heavy-ion beams from any direction may be as heavy as 600 tons in our estimation. By employing high-temperature superconducting (HTS) wires in these rotating gantries and increasing the magnetic field generated by the deflecting coils, the total weight of the rotating gantry can be reduced to around the weight of those used for proton radiotherapy. A project for developing an HTS deflecting magnet for heavy-ion radiotherapy has been underway since 2013, supported by the Japanese Ministry of Economy, Trade and Industry (METI) and the Japan Agency for Medical Research and Development (AMED). The aim of this project is to develop fundamental technologies for designing and fabricating HTS deflecting magnets, such as irregular magnetic field estimating techniques, design technology for HTS magnets, high-precision HTS coil winding technology, AC loss estimating techniques, and thermal runaway estimating techniques and to fabricate a small model of an HTS deflecting magnet and evaluate its performance. In this paper, the project's progress will be described.

  13. Design of a Probe for Strain Sensitivity Studies of Critical Current Densities in SC Wires and Tapes

    SciTech Connect

    Dhanaraj, N.; Barzi, E.; Turrioni, D.; Rusy, A.; Lombardo, V.; /Fermilab

    2011-07-01

    The design of a variable-temperature probe used to perform strain sensitivity measurements on LTS wires and HTS wires and tapes is described. The measurements are intended to be performed at liquid helium temperatures (4.2 K). The wire or tape to be measured is wound and soldered on to a helical spring device, which is fixed at one end and subjected to a torque at the free end. The design goal is to be able to achieve {+-} 0.8 % strain in the wire and tape. The probe is designed to carry a current of 2000A.

  14. Cost Effective Open Geometry HTS MRI System amended to BSCCO 2212 Wire for High Field Magnets

    SciTech Connect

    Kennth Marken

    2006-08-11

    The original goal of this Phase II Superconductivity Partnership Initiative project was to build and operate a prototype Magnetic Resonance Imaging (MRI) system using high temperature superconductor (HTS) coils wound from continuously processed dip-coated BSCCO 2212 tape conductor. Using dip-coated tape, the plan was for MRI magnet coils to be wound to fit an established commercial open geometry, 0.2 Tesla permanent magnet system. New electronics and imaging software for a prototype higher field superconducting system would have added significantly to the cost. However, the use of the 0.2 T platform would allow the technical feasibility and the cost issues for HTS systems to be fully established. Also it would establish the energy efficiency and savings of HTS open MRI compared with resistive and permanent magnet systems. The commercial goal was an open geometry HTS MRI running at 0.5 T and 20 K. This low field open magnet was using resistive normal metal conductor and its heat loss was rather high around 15 kolwatts. It was expected that an HTS magnet would dissipate around 1 watt, significantly reduce power consumption. The SPI team assembled to achieve this goal was led by Oxford Instruments, Superconducting Technology (OST), who developed the method of producing commercial dip coated tape. Superconductive Components Inc. (SCI), a leading US supplier of HTS powders, supported the conductor optimization through powder optimization, scaling, and cost reduction. Oxford Magnet Technology (OMT), a joint venture between Oxford Instruments and Siemens and the world’s leading supplier of MRI magnet systems, was involved to design and build the HTS MRI magnet and cryogenics. Siemens Magnetic Resonance Division, a leading developer and supplier of complete MRI imaging systems, was expected to integrate the final system and perform imaging trials. The original MRI demonstration project was ended in July 2004 by mutual consent of Oxford Instruments and Siemens. Between

  15. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are funny (well,…

  16. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  17. HTS Wire Development Workshop: Proceedings

    SciTech Connect

    Not Available

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  18. Mechanical and transport properties of IBAD/EDDC-SmBCO coated conductor tapes during fatigue loading

    NASA Astrophysics Data System (ADS)

    Shin, Hyung-Seop; Dedicatoria, Marlon J.

    2011-06-01

    In electrical devices like superconducting motor, generator and SMES, HTS coated conductor (CC) tapes will be subjected to alternating stress or strain during manufacturing and operation. The repeated loading will affect the mechanical integrity and eventually the electrical transport property of CC tapes. Therefore in such applications, electro-mechanical property of CC tapes should be evaluated. In this study, the endurance of an IBAD/EDDC-SmBCO CC tape under high-cycle fatigue loading has been evaluated. Applied maximum stress and fatigue life ( S-N) relation was obtained at 77 K. The mechanical properties and the critical current, I c, of the sample under fatigue loading were investigated at 77 K. Considering the practical operating environment, the effect of the stress ratio R, on the degradation behavior of I c under fatigue loading was also examined.

  19. Inhomogeneity effects in HTS coated conductors used as resistive FCLs in medium voltage grids

    NASA Astrophysics Data System (ADS)

    Colangelo, Daniele; Dutoit, Bertrand

    2012-09-01

    For resistive fault current limiters (RFCLs) based on high temperature superconducting coated conductors (HTS-CCs), inhomogeneity, in terms of critical current and geometrical imperfections such as stabilizer and substrate thicknesses, plays a very important role and it may limit the penetration of such devices into the electrical market. This paper presents an electrothermal model, developed in SimPowerSystem™, able to describe the transient response of HTS-CC candidates with different degrees of inhomogeneity, both in terms of critical current and of stabilizer thickness. Critical current inhomogeneity has been modeled with Gaussian distributions. The layer thicknesses used in the simulations have been chosen by fitting the temperature dependence of real tape resistances. Our approach considers relative inhomogeneity positions as well as thermal conduction along the HTS-CC length. The model is tuned using experimental measurements made on ReBaCuO coated conductors. A new dynamical thermal calibration of the model is proposed using finite element method calculations. Inhomegeneity effects with different possible faults (e.g. three phase and single phase short-circuit) are presented.

  20. Development of an HTS hydroelectric power generator for the hirschaid power station

    NASA Astrophysics Data System (ADS)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  1. Structural design of the toroidal configuration of the HTS SMES cooling system

    NASA Astrophysics Data System (ADS)

    Yeom, H. K.; Koh, D. Y.; Ko, J. S.; Kim, H. B.; Hong, Y. J.; Kim, S. H.; Seong, K. C.

    2011-11-01

    The superconducting magnetic energy storage (SMES) system is working on around 30 K, because the magnet is made of high temperature superconductor. To maintain the cryogenic temperature, the superconducting coil is cooled by cryogen, helium gas or liquid neon. But there are some weak points in the cryogen cooling system. For example periodic charge of the cryogen and size is big and so on. So, we have designed the conduction cooling system for toroidal configuration HTS SMES. The toroidal type HTS SMES has some merits, so it is very small magnetic field leakage, and magnetic field applied perpendicular to the tape surface can be reduced. Our system has 28 numbers of HTS double pancake coils and they are arrayed toroidal configuration. The toroidal inner radius is 162 mm, and outer radius is 599 mm, and height is about 162 mm. In this study, we have designed the cooling structure and analyzed temperature distribution of cooling path, thermal stress and deformation of the cooling structure.

  2. The Mechanical Design Optimization of a High Field HTS Solenoid

    SciTech Connect

    Lalitha, SL; Gupta, RC

    2015-06-01

    This paper describes the conceptual design optimization of a large aperture, high field (24 T at 4 K) solenoid for a 1.7 MJ superconducting magnetic energy storage device. The magnet is designed to be built entirely of second generation (2G) high temperature superconductor tape with excellent electrical and mechanical properties at the cryogenic temperatures. The critical parameters that govern the magnet performance are examined in detail through a multiphysics approach using ANSYS software. The analysis results formed the basis for the performance specification as well as the construction of the magnet.

  3. R&D ERL: HTS Solenoid

    SciTech Connect

    Gupta, R.; Muratore, J.; Plate, S.

    2010-01-01

    An innovative feature of the ERL project is the use of a solenoid made with High Temperature Superconductor (HTS) with the Superconducting RF cavity. The HTS solenoid design offers many advantages because of several unique design features. Typically the solenoid is placed outside the cryostat which means that the beam gets significantly defused before a focusing element starts. In the current design, the solenoid is placed inside the cryostat which provides an early focusing structure and thus a significant reduction in the emittance of the electron beam. In addition, taking full advantage of the high critical temperature of HTS, the solenoid has been designed to reach the required field at {approx}77 K, which can be obtained with liquid nitrogen. This significantly reduces the cost of testing and allows a variety of critical pre-tests which would have been prohibitively expensive at 4 K in liquid helium because of the additional requirements of cryostat and associated facilities.

  4. Thermal and mechanical properties of advanced impregnation materials for HTS cables and coils

    NASA Astrophysics Data System (ADS)

    Bagrets, N.; Otten, S.; Weiss, K.-P.; Kario, A.; Goldacker, W.

    2015-12-01

    In the growing field of high-temperature superconducting (HTS) applications, finding an appropriate impregnation material for cables and coils remains a challenging task. In HTS cables and coils, tapes have to be able to withstand mechanical loads during operation. Impregnation is playing a role as mechanical stabilization. However, material properties usually change significantly when going to low temperatures which can decrease performance of superconducting devices. For example, a large mismatch in thermal expansion between a conductor and impregnation material at low temperatures can lead to delamination and to degradation of the critical current. Impregnation materials can insulate tapes thermally which can lead to damage of the superconducting device in case of quench. Thus, thermal conductivity is an important property which is responsible for the temperature distribution in a superconducting cable or in a coil. Due to Lorentz forces acting on structural materials in a superconducting device, the mechanical properties of these materials should be investigated at operating temperatures of this device. Therefore, it is important to identify an advanced impregnation material meeting all specific requirements. In this paper, thermal and mechanical properties of impregnation material candidates with added fillers are presented in a temperature range from 300 K to 4 K.

  5. Single and three-phase AC losses in HTS superconducting power transmission line prototype cables

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; Coulter, J.Y.; Fleshler, S.

    1997-11-01

    AC losses in two, one-meter-long lengths of HTS prototype multi-strand conductors (PMC`s) are measured with a temperature-difference calorimeter. Both single-phase and three-phase losses are examined with ac currents up to 1,000 A rms. The calorimeter, designed specifically for these measurements, has a precision of 1 mW. PMC {number_sign}1 has two helically-wound, non-insulated layers of HTS tape (19 tapes per layer), each layer wrapped with opposite pitch. PMC {number_sign}2 is identical except for insulation between the layers. The measured ac losses show no significant effect of interlayer insulation and depend on about the third power of the current--a result in agreement with the Bean-Norris model adapted to the double-helix configuration. The three-phase losses are a factor of two higher than those exhibited by a single isolated conductor, indicating a significant interaction between phases.

  6. How filaments can reduce AC losses in HTS coated conductors: a review

    NASA Astrophysics Data System (ADS)

    Grilli, Francesco; Kario, Anna

    2016-08-01

    Second-generation high-temperature superconductor (HTS) tapes, known also as coated conductors, are very promising tapes for HTS applications, in virtue of their extremely high critical current density, in-field behavior, and mechanical strength. Yet, the extremely large (typically in the range 1000-10 000) width-to-thickness ratio of the superconducting material makes them prone to high power dissipation in the presence of time-varying magnetic fields perpendicular to their flat face—a condition frequently met in several applications. Since the dissipation is directly proportional to the square of the superconductor's width, an obvious way of reducing it is by striating the superconductor into narrow filaments (stripes): in that case, provided that the filaments are electromagnetically uncoupled, the losses are reduced by a factor equal to the number of filaments. In the past two decades, many researchers from groups around the world have tried to apply this idea to practical conductors using different techniques. The aim of this paper is to provide a review of such efforts, focusing on the different approaches to make filamentized conductors, on the effectiveness of the AC loss reduction, and on the applicability of those techniques to long lengths.

  7. How filaments can reduce AC losses in HTS coated conductors: a review

    NASA Astrophysics Data System (ADS)

    Grilli, Francesco; Kario, Anna

    2016-08-01

    Second-generation high-temperature superconductor (HTS) tapes, known also as coated conductors, are very promising tapes for HTS applications, in virtue of their extremely high critical current density, in-field behavior, and mechanical strength. Yet, the extremely large (typically in the range 1000–10 000) width-to-thickness ratio of the superconducting material makes them prone to high power dissipation in the presence of time-varying magnetic fields perpendicular to their flat face—a condition frequently met in several applications. Since the dissipation is directly proportional to the square of the superconductor's width, an obvious way of reducing it is by striating the superconductor into narrow filaments (stripes): in that case, provided that the filaments are electromagnetically uncoupled, the losses are reduced by a factor equal to the number of filaments. In the past two decades, many researchers from groups around the world have tried to apply this idea to practical conductors using different techniques. The aim of this paper is to provide a review of such efforts, focusing on the different approaches to make filamentized conductors, on the effectiveness of the AC loss reduction, and on the applicability of those techniques to long lengths.

  8. US effort on HTS power transformers

    NASA Astrophysics Data System (ADS)

    Mehta, S.

    2011-11-01

    Waukesha Electric Systems has been working in HTS power transformers development program under the auspices of US Government Department of Energy since 1994. This presentation will describe various milestones for this program and program history along with the lessons learned along the way. Our motivations for working on this development program based on man benefits offered by HTS power transformers to power delivery systems will be discussed. Based on various issues encountered during execution of many HTS projects, DOE has set up an independent program review process that is lead by team of experts. This team reviews are integral part of all DOE HTS projects. Success of all projects would be greatly enhanced by identifying critical issues early in the program. Requiring appropriate actions to mitigate the issues before processing further will lead to proactive interrogation and incorporation of expert’s ideas in the project plans. Working of this review process will be also described in this presentation. Waukesha Electric Systems team including: Superpower-Inc, Oak Ridge National Laboratory, University of Houston Center for Superconductivity and Southern California Edison company was awarded a cost share grant by US Government in 2010 for development of a fault current limiting HTS power transformer. This multi year’s program will require design, manufacture, installation, and monitoring of a 28 MVA tree phase transformer installed at Irvine CA. Smart Grid demonstration site. Transformer specifications along with requirements for fault current limiting and site requirement will be discussed. Design and development of various sub systems in support of this program including: HTS conductor performance specification, Dielectric system design approach, Dewar development for containing phase assemblies, cryo-cooling system design approach, etc. will be described. Finally; overall program schedule, critical milestone events, test plans and progress to date will

  9. Hybrid Current Lead Design of HTS SMES

    NASA Astrophysics Data System (ADS)

    Ge, T.; Ren, L.; He, Q.; Jiao, F.; Dong, H.; Jin, T.; Zhou, S.

    In application of Superconducting magnetic energy storage device (SMES), current lead represents a key development component. This paper will focus on parameters and structure design of hybrid high-temperature superconductor (HTS) current lead in a SMES with 100 kJ/100 kW class. Based on the theoretical analysis, finite element simulation (FEA) has been used. It studies the thermal influence of variable cross-sectional area, HTS material and the connection between current lead and cryocooler. Some improvements have been proposed to reduce heat losses. At the end of this paper, a whole procedure about hybrid current lead design is given.

  10. Recording-tape position sensor

    NASA Technical Reports Server (NTRS)

    Schoppet, G. C.

    1977-01-01

    Device uses tachometer pulses from capstan and reset pulse from one reel to sense count of tach pulses per revolution of reel. Number of pulses is direct measurement of tape stack radius and is independent of tape speed or direction.

  11. Development of a brushless HTS exciter for a 10 kW HTS synchronous generator

    NASA Astrophysics Data System (ADS)

    Bumby, Chris W.; Badcock, Rodney A.; Sung, Hae-Jin; Kim, Kwang-Min; Jiang, Zhenan; Pantoja, Andres E.; Bernardo, Patrick; Park, Minwon; Buckley, Robert G.

    2016-02-01

    HTS synchronous generators, in which the rotor coils are wound from high-T c superconducting wire, are exciting attention due to their potential to deliver very high torque and power densities. However, injection of the large DC currents required by the HTS rotor coils presents a technical challenge. In this paper we discuss the development of a brushless HTS exciter which operates across the cryostat wall to inject a superconducting DC current into the rotor coil circuit. This approach fundamentally alters the thermal load upon the cryogenic system by removing the need for thermally inefficient normal-conducting current leads. We report results from an experimental laboratory device and show that it operates as a constant voltage source with an effective internal resistance. We then discuss the design of a prototype HTS-PM exciter based on our experimental device, and describe its integration with a demonstration HTS generator. This 200 RPM, 10 kW synchronous generator comprises eight double pancake HTS rotor coils which are operated at 30 K, and are energised to 1.5 T field through the injection of 85 A per pole. We show how this excitation can be achieved using an HTS-PM exciter consisting of 12 stator poles of 12 mm YBCO coated-conductor wire and an external permanent magnet rotor. We demonstrate that such an exciter can excite the rotor windings of this generator without forming a thermal-bridge across the cryostat wall. Finally, we provide estimates of the thermal load imposed by our prototype HTS-PM exciter on the rotor cryostat. We show that duty cycle operation of the device ensures that this heat load can be minimised, and that it is substantially lower than that of equivalently-rated conventional current leads.

  12. From BCS to Hts and Rts

    NASA Astrophysics Data System (ADS)

    Chu, C. W.

    2008-12-01

    Great progress has been made in high temperature superconductivity (HTS) science, material and technology in the 20 years since its discovery. The next grand challenge will be room temperature superconductivity (RTS). Room temperature superconductivity, if achieved, can change the world both scientifically and technologically. Unfortunately, it has long been considered by some to belong to the domain of science fiction and to occur only "at an astronomical temperature and at an astronomical distance". With the advent of HTS in 1987, the outlook for RTS has become much brighter. Currently, there appears to be no reason, either theoretical or experimental, why room temperature superconductivity should be impossible. BCS theory has provided the basic framework for the occurrence and understanding of superconductivity, but, since its inception, it has failed to show where and how to find superconductivity at higher temperatures. To date, empiricism remains the most effective way to discover superconductors with high transition temperatures. In this paper based on the talk given at the Professor Yang's 85th birthday celebration on October 31, 2007 in Singapore, I shall summarize the search for superconductors of higher Tc prior to and after the discovery of HTS, list the common features of HTS and describe some approaches toward RTS that we are currently pursuing.

  13. Current distribution among layers of single phase HTS cable conductor

    NASA Astrophysics Data System (ADS)

    Zheng, Y. B.; Wang, Y. S.; Pi, W.; Ju, P.; Wang, Y. S.

    2014-12-01

    High temperature superconducting (HTS) power cable shows high application prospect in modern power transmission, as it is superior over conventional transmission lines in high engineering current density and environmental friendliness. Its configuration is generally composed of several HTS layers designed with the principle of uniform current distribution, but there are few experimental results to verify the distribution. In this paper, a HTS cable model was designed based on the principle of uniform current, and the current distributions among layers in an HTS cable model were measured by Rogowski coils. The results provide an important basis for design of multi-layer HTS cable.

  14. A Test of HTS Power Cable in a Sweeping Magnetic Field

    SciTech Connect

    Piekarz, H.; Hays, S.; Blowers, J.; Shiltsev, V.; /Fermilab

    2011-11-29

    Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s ramping rate. The B-field orientation toward the HTS strands wide surface was varied from 0{sup 0} to 10{sup 0}, in steps of 1{sup 0}. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. For the validity of these measurements, the power losses of a short sample cable composed of multiple LTS wire strands were also performed to compare with the known data. The test arrangement of the power cable is described, and the test results are compared with the projections for the eddy and hysteresis power losses using the fine details of the test cable structures.

  15. Tamper tape seals

    SciTech Connect

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R&D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique {open_quotes}fingerprint{close_quotes} characteristics that can be accessed as desired.

  16. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  17. A HTS scanning magnet and AC operation

    NASA Astrophysics Data System (ADS)

    Hatanaka, K.; Nakagawa, J.; Fukuda, M.; Yorita, T.; Saito, T.; Sakemi, Y.; Kawaguchi, T.; Noda, K.

    2010-04-01

    A scanning magnet using high-temperature superconductor (HTS) wire was designed, built, and tested for its suitability as a beam scanner. After successful cooling tests, the magnet performance was studied using DC and AC currents. With DC current the magnet was successfully operated to generate designed field distributions and effective length. In AC mode, the magnet was operated at frequencies of 30-59 Hz and a temperature of 77 K as well as 10-20 Hz and 20 K. The power losses dissipated in the coils were measured and compared with the model calculations. The observed losses per cycle were independent of the frequency and the scaling law of the transport current was consistent with theoretical predictions for hysteretic losses in HTS wires.

  18. Mobile conduction-cooled HTS SMES

    NASA Astrophysics Data System (ADS)

    Ren, L.; Tang, Y.; Li, J.; Shi, J.; Chen, L.; Guo, F.; Fang, J.; Wen, J.

    2010-11-01

    An immovable 35 kJ/7 kW high- Tc superconducting magnetic energy storage (HTS SMES) system had been developed in the Electric Power System Dynamic Simulation Laboratory, Huazhong University of Science and Technology in 2005. In order to adapt for on-site experimental conditions, the mechanical configuration of the magnet is reinforced and the SMES system is assembled in a special container to be freighted to the actual power system for the feasibility study on different applications at different sites. The mobile HTS SMES system had withstood various kinds of poor road surfaces and then arrived at the experimental site on August 18, 2009. In this paper, the reconstructed configuration and the shock absorption of the magnet are presented. The field test results show that the mobile SMES system can operate on the power network at different locations and suppress effectively power fluctuation of the generator terminal.

  19. Progress in development of high capacity magnetic HTS bearings

    NASA Astrophysics Data System (ADS)

    Kummeth, P.; Nick, W.; Neumueller, H.-W.

    2005-10-01

    HTS magnetic bearings are inherently stable without an active feedback system. They provide low frictional losses, no wear and allow operation at high rotational speed without lubrication. So they are very promising for use in motors, generators and turbines. We designed and constructed an HTS radial bearing for use with a 400 kW HTS motor. It consists of alternating axially magnetized permanent magnet rings on the rotor and a segmented YBCO stator. Stator cooling is performed by liquid nitrogen, the temperature of the stator can be adjusted by varying the pressure in the cryogenic vessel. At 68 K maximum radial forces of more than 3.7 kN were found. These results range within the highest radial bearing capacities reported worldwide. The encouraging results lead us to develop a large heavy load HTS radial bearing. Currently a high magnetic gradient HTS bearing for a 4 MVA synchronous HTS generator is under construction.

  20. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  1. Recent Progress in Electrical Insulation Techniques for HTS Power Apparatus

    NASA Astrophysics Data System (ADS)

    Hayakawa, Naoki; Kojima, Hiroki; Hanai, Masahiro; Okubo, Hitoshi

    This paper describes the electrical insulation techniques at cryogenic temperatures, i.e. Cryodielectrics, for HTS power apparatus, e.g. HTS power transmission cables, transformers, fault current limiters and SMES. Breakdown and partial discharge characteristics are discussed for different electrical insulation configurations of LN2, sub-cooled LN2, solid, vacuum and their composite insulation systems. Dynamic and static insulation performances with and without taking account of quench in HTS materials are also introduced.

  2. A terabyte linear tape recorder

    NASA Technical Reports Server (NTRS)

    Webber, John C.

    1994-01-01

    A plan has been formulated and selected for a NASA Phase 2 SBIR award for using the VLBA tape recorder for recording general data. The VLBA tape recorder is a high-speed, high-density linear tape recorder developed for Very Long Baseline Interferometry (VLBI) which is presently capable of recording at rates up to 2 Gbit/sec and holding up to 1 Terabyte of data on one tape, using a special interface and not employing error correction. A general-purpose interface and error correction will be added so that the recorder can be used in other high-speed, high-capacity applications.

  3. Tape casting of magnesium oxide.

    SciTech Connect

    Ayala, Alicia; Corral, Erica L.; Loehman, Ronald E.; Bencoe, Denise Nora; Reiterer, Markus; Shah, Raja A.

    2008-02-01

    A tape casting procedure for fabricating ceramic magnesium oxide tapes has been developed as a method to produce flat sheets of sintered MgO that are thin and porous. Thickness of single layer tapes is in the range of 200-400 {micro}m with corresponding surface roughness values in the range of 10-20 {micro}m as measured by laser profilometry. Development of the tape casting technique required optimization of pretreatment for the starting magnesium oxide (MgO) powder as well as a detailed study of the casting slurry preparation and subsequent heat treatments for sintering and final tape flattening. Milling time of the ceramic powder, plasticizer, and binder mixture was identified as a primary factor affecting surface morphology of the tapes. In general, longer milling times resulted in green tapes with a noticeably smoother surface. This work demonstrates that meticulous control of the entire tape casting operation is necessary to obtain high-quality MgO tapes.

  4. Multifilamentary niobium tin superconductor tape

    NASA Technical Reports Server (NTRS)

    Brisbin, P. H.; Coles, W. D.

    1975-01-01

    In the method proposed for fabricating multifilamentary Nb3Sn tape, filamentary superconducting paths are produced in standard commercial superconductor tape by chemical milling of separator slots through the Nb3Sn layer. The multifilament configuration features a matrix of ten 1.2 mm wide parallel helical superconducting paths along the length of the tape. The paths are spaced 0.4 mm apart. Tapes tested as small pancake coils demonstrated the integrity and continuity of the matrix, and showed that critical current was sustained in direct proportion to retained superconductor.

  5. Development of a compact HTS lead unit for the SC correction coils of the SuperKEKB final focusing magnet system

    NASA Astrophysics Data System (ADS)

    Zong, Zhanguo; Ohuchi, Norihito; Tsuchiya, Kiyosumi; Arimoto, Yasushi

    2016-09-01

    Forty-three superconducting (SC) correction coils with maximum currents of about 60 A are installed in the SuperKEKB final focusing magnet system. Current leads to energize the SC correction coils should have an affordable heat load and fit the spatial constraints in the service cryostat where the current leads are installed. To address the requirements, design optimization of individual lead was performed with vapor cooled current lead made of a brass material, and a compact unit was designed to accommodate eight current leads together in order to be installed with one port in the service cryostat. The 2nd generation high temperature SC (HTS) tape was adopted and soldered at the cold end of the brass current lead to form a hybrid HTS lead structure. A prototype of the compact lead unit with HTS tape was constructed and tested with liquid helium (LHe) environment. This paper presents a cryogenic measurement system to simulate the real operation conditions in the service cryostat, and analysis of the experimental results. The measured results showed excellent agreement with the theoretical analysis and numerical simulation. In total, 11 sets of the compact HTS lead units were constructed for the 43 SC correction coils at KEK. One set from the mass production was tested in cryogenic conditions, and exhibited the same performance as the prototype. The compact HTS lead unit can feed currents to four SC correction coils simultaneously with the simple requirement of controlling and monitoring helium vapor flow, and has a heat load of about 0.762 L/h in terms of LHe consumption.

  6. Bi-2212/Ag tape conductor and coil development

    SciTech Connect

    Albert, G.W.; Leung, E.M.; Zhou, R.; Salazar, K.V.

    1996-12-31

    This paper presents recent progress by Los Alamos National Laboratory/Superconductivity Technology Center (LANL/STC) and Lockheed Martin Corporation/Advanced Development Operations (LMQADO) Energy and Power Systems group to jointly develop and test high temperature superconductor coils for practical applications such as motors, generators, magnetic bearings, superconducting magnetic energy storage (SMES), MAGLEV trains, or electrical inductors. Critical currents of 105 A/cm{sup 2} have been achieved in a Bi-2212/Ag tape conductor using a patented Ag addition process to improve core morphology and uniformity. Results of testing to measure key conductor parameters are presented along with design and analysis details of a general-purpose multi-layer HTS coil.

  7. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  8. Design of Conduction-cooled HTS Coils for a Rotating Gantry

    NASA Astrophysics Data System (ADS)

    Takayama, Shigeki; Koyanagi, Kei; Yamaguchi, Akiko; Tasaki, Kenji; Kurusu, Tsutomu; Ishii, Yusuke; Amemiya, Naoyuki; Ogitsu, Toru; Noda, Koji

    Carbon ion cancer therapy is becoming more widespread due to its high curative effects and low burden on patients. Carbon ions are delivered to patients through electromagnets on a rotating gantry.A rotating gantry is attractive because it allows carbon ions to irradiate a tumor from any direction without changing the posture of the patient. On the other hand, because of the high magnetic rigidity of carbon ions, the weight of a rotating gantry for carbon cancer therapy is about three times higher than one for proton cancer therapy, according to our estimation. The use of high-temperature superconducting (HTS) magnets has been considered for reducing the size of the rotating gantry for carbon cancer therapy. The target weight is 200 t or less,which is equivalent to the weight of a typical rotating gantry for proton cancer therapy.In this study, the magnet layout of the rotating gantry and the superconducting magnets were designed from the viewpoint of beam optics.When applying high-temperature superconductors to accelerator magnets, there are some issues that should be considered, for example, the influence of tape magnetization and manufacturing accuracy on the field quality, the thermal stability of the conduction-cooled HTS coils under an alternating magnetic field, and methods to protect the coils from thermal runaway caused by an anomalous thermal input such as that due to beam loss. First, the thermal stability of the conduction-cooled HTS coils was simulated numerically, and the thermal runaway current was calculated in a static situation.

  9. Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory

    SciTech Connect

    James, David Randy; Sauers, Isidor; Ellis, Alvin R; Tuncer, Enis; Gouge, Michael J; Demko, Jonathan A; Duckworth, Robert C; Rey, Christopher M

    2009-01-01

    In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

  10. C-axis critical current density of second-generation YBCO tapes.

    SciTech Connect

    Jia, Y.; Hua, J.; Crabtree, G. W.; Kwok, W. K.; Welp, U.; Malozemoff, A. P.; Rupich, M.; Fleshler, S.; Materials Science Division; American Superconductor Corp.

    2010-10-01

    We report on measurements of the temperature and field dependence of the c-axis critical current density (J{sub c}{sup c}) obtained on mesa structures that were patterned into the YBCO layer of second-generation HTS tapes. We find the J{sub c}{sup c}-values of {approx}4 kA cm{sup -2} at 77 K and self-field, corresponding to an unexpectedly high anisotropy in the critical current density J{sub c}{sup ab}/J{sub c}{sup c} of 500-600. C-axis current flow is expected to arise in applications such as the helically wound wires in HTS cables. A simple estimate is given of the fraction of tape width for such a c-axis flow; while in our samples this fraction is approximately 5% for a typical geometry, the fraction will grow linearly with increasing current density anisotropy and could affect the current-carrying ability of the tape.

  11. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    SciTech Connect

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

  12. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  13. Centrally managed tapes at DESY

    SciTech Connect

    Hell, O.

    1994-12-31

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years.

  14. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  15. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides instructions for…

  16. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  17. Thermal analysis for the HTS stator consisting of HTS armature windings and an iron core for a 2.5 kW HTS generator

    NASA Astrophysics Data System (ADS)

    Song, P.; Qu, T.-M.; Lai, L.-F.; Wu, M.-S.; Yu, X.-Y.; Han, Z.

    2016-05-01

    Most present demonstrations of high-temperature superconducting (HTS) synchronous motors/generators are partially superconducting, only installing HTS coils on the rotor as excitation windings. The possible applicability of HTS armature windings is an interesting research topic because these windings can certainly increase the power density attributed to a potentially high armature loading capacity. In this study, we analysed the thermal behaviours of a developed 2.5 kW-300 rpm synchronous generator prototype that consists of an HTS stator with Bi-2223-Ag armature windings on an iron core and a permanent magnet (PM) rotor. The entire HTS stator, including the iron core, is cooled with liquid nitrogen through conduction cooling. The rated frequency is set at 10 Hz to reduce AC loss. The properties of the HTS windings and the iron core are characterized, and the temperatures in the HTS stator under different operation conditions are measured. The estimated iron loss is 11.5 W under operation in 10 Hz at liquid nitrogen temperature. Conduction cooling through the silicon iron core is sufficient to cool the iron core and to compensate for the temperature increment caused by iron loss. The stable running capacity is limited to 1.6 kW when the armature current is 12.6 A (effective values) due to the increasing temperature in the slots as a result of the AC loss in the HTS coils. The thermal contact between the HTS coils and the cooling media should be improved in the future to take away the heat generated by AC loss.

  18. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  19. Superconducting tape characterization under flexion

    NASA Astrophysics Data System (ADS)

    Álvarez, A.; Suárez, P.; Cáceres, D.; Pérez, B.; Cordero, E.; Castaño, A.

    2002-08-01

    Electrotechnical applications of high temperature superconducting materials are limited by the difficulty of constructing classical windings with ceramic materials. While Bi-2223 tape may be a solution, it cannot be bent to radii less than a certain value since its superconducting capacity disappears. We describe an automated measurement system of the characteristics of this tape under flexion. It consists of a device that coils the tape over cylinders with different radii. At the same time, the parameters of its superconducting behaviour (e.g. resistance) are taken and processed. This system was developed at the “Benito Mahedero Laboratory of Superconducting Electrical Applications” in the University of Extremadura.

  20. Study on Quench Protection of HTS Coil Wound of YBCO Conductor

    NASA Astrophysics Data System (ADS)

    Fu, Youkun; Tsukamoto, Osami; Furuse, Mitsuho

    Recent progress of long YBCO coated conductors is remarkable and coils wound of YBCO conductors will be developed in near future. YBCO coated conductors that are made by deposition of thin YBCO film on high resistance metal substrates such as Hastelloy and nickel tapes are highly resistive when they are quenched. Therefore, measures for stabilization and quench protection are more important for YBCO conductors than for Bi/Ag sheathed tapes which have low resistive silver matrix. Though HTS conductors working at liquid nitrogen temperature are hard to be quenched, the conductors still have possibilities of quenches due to local defects for example. We studied necessary amount of copper stabilizer to protect the YBCO conductors in coils from damages caused by hot spots due to quenches. In the work we numerically calculated maximum hot spot temperature of a YBCO conductor quenched by a local disturbance during the sequence of quench detection and energy dump. In the analysis, necessary amounts of copper to keep the maximum hot spot temperature below a threshold are calculated. Based on the analysis, optimum conductor design is discussed to obtain safe and high current density conductors.

  1. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  2. Canadian Contemporary Issues on Tape

    ERIC Educational Resources Information Center

    Shapter, Jean

    1974-01-01

    Four tapes with interviews with experts in the designated fields comprise the series: a) Canada's Foreign Relations, 1867-1919; b) Canada's Foreign Relations, 1919-1945; c) Canada and China, and d) Canadian Diplomacy and Foreign Policy. (JA)

  3. Waveform control pulse magnetization for HTS bulk magnet

    NASA Astrophysics Data System (ADS)

    Ida, Tetsuya; Shigeuchi, Koji; Okuda, Sayo; Watasaki, Masahiro; Izumi, Mitsuru

    2016-03-01

    For the past 10 years, we have studied high-temperature superconducting (HTS) bulk magnets for use in electromagnetic rotating machines. If the magnetic field effectively magnetizes the HTS bulk, then the size of the motor and generator can be reduced without a reduction in output. We showed that the melt-textured Gd-Ba-Cu-O HTS bulk effectively traps a high magnetic field using waveform control pulse magnetization (WCPM). WCPM makes it possible to generate any pulsed magnetic field waveform by appropriately changing the duty ratio of the pulse width modulation. By chopping so that the pulsed magnetic field has a period of about 1ms, the WCPM technology enables active control of the rise time and suppresses magnetic flux motion that decreases magnetization efficiency. This method is also useful for any HTS bulk magnet, and the high magnetic flux density is trapped in the HTS bulk by a single pulse magnetic field. We developed a magnetizer that has a feedback system from the penetrated magnetic flux density to realize WCPM. In this research, using only a single pulse magnetic field of WCPM method at 77K, an HTS bulk with a 45mm diameter and 19mm thickness trapped a maximum magnetic field of 1.63T, which is more than 90% of the trapped magnetic flux density by FC magnetization. This result suggests that the pulse magnetizing method can replace the conventional field-cooled method and promote the practical use of HTS magnets for electromagnetic power applications.

  4. Upgrade of SULTAN/EDIPO for HTS Cable Test

    NASA Astrophysics Data System (ADS)

    Wesche, R.; Bruzzone, P.; Uglietti, D.; Bykovsky, N.; Lewandowska, M.

    CRPP hosts two unique conductor test facilities SULTAN (SUpraLeiter TestANlage) and EDIPO (European DIPOle). They allow the test of high current superconductors in high magnetic fields (SULTAN 11 T, EDIPO 12.5 T). In both facilities sample currents up to 100 kA can be supplied by means of a NbTi transformer. Presently the facilities are upgraded for the test of high current high-temperature superconductor (HTS) samples. For HTS conductor testing at temperatures between 20 and 50 K, the heat flux between the HTS sample under test and the NbTi transformer needs to be limited to around 10 W per conductor leg by means of an HTS adapter connecting them. The second required upgrade is the supply of intermediate temperature helium (20-50 K) to the HTS test conductor. It is mandatory that the helium gas coming from the HTS conductor under test can be returned to the cryoplant as cold gas (T < 20 K). To reach this goal a tube-in-tube heat exchanger has been manufactured in which 4.5 K helium coming from the cryoplant is in counter flow with the warm gas leaving the HTS test conductor.

  5. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  6. Method of forming an HTS article

    DOEpatents

    Bhattacharya, Raghu N.; Zhang, Xun; Selvamanickam, Venkat

    2014-08-19

    A method of forming a superconducting article includes providing a substrate tape, forming a superconducting layer overlying the substrate tape, and depositing a capping layer overlying the superconducting layer. The capping layer includes a noble metal and has a thickness not greater than about 1.0 micron. The method further includes electrodepositing a stabilizer layer overlying the capping layer using a solution that is non-reactive to the superconducting layer. The superconducting layer has an as-formed critical current I.sub.C(AF) and a post-stabilized critical current I.sub.C(PS). The I.sub.C(PS) is at least about 95% of the I.sub.C(AF).

  7. What's up with duct tape

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.

    2005-03-01

    Recent research suggests that almost any tape can be made to work for a core-to-collar joint when perfectly applied. Given all the better choices available and all the problems that can and do occur in the field, we would not recommend that cloth-backed (natural) rubber-adhesive tapes be used, unless they can pass a suitable E2343 test. If visual degradation is an important factor, Oriented Polypropylene (OPP) and cloth-backed tapes should be avoided. While tapes that fail usually show visual degradation, the converse is not always true. We speculate, however, that visually degraded tapes are more likely to be susceptible to damage from vibration and other mechanical stresses. Conventional nylon straps are quite prone to fail at higher temperatures, but no systematic studies have yet been done across product classes. UL has proposed a new standard for straps, but the protocol for the current UL test does not, however, suggest that it would be a good indicator of durability. Products meeting the new UL standard for straps should be independently tested for the failure modes observed in the field and laboratory to determine if that test is a reasonable indicator of durability. Until a suitable test for strap durability exists, they recommend that only high temperature nylon or metal straps be used--especially in cases where tapes may be sensitive to mechanical stresses.

  8. Tape Storage Optimization at BNL

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2011-12-01

    The BNL's RHIC and Atlas Computing Facility (RACF), is supporting the RHIC experiment as its Tier0 center and the Atlas/LHC as a Tier1 center. The RACF had to address the issue of efficient access to data stored to disk and tape storage. Randomly restoring files out of tapes destroys access performance to tape by causing too frequently, high latency and time consuming tape mount and dismount. BNL's mass storage system currently holds more than 16 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on a code from OakRidge National Lab, and then it was renamed to BNL Batch at 2005 after some major modifications and enhancements. The new BNL Batch, ERADAT, provides dynamic HPSS resource management, schedule jobs efficiently, enhanced visibility of real-time staging activities and advanced error handling, to maximize the tape staging performance. ERADAT is the interface between HPSS and other applications such as the DataCarousel, our home developed production system and dCache. Scalla/Xrootd MSS can also be interfaced with HPSS via DataCarousel. ERADAT has demonstrated great performance in BNL and other institute.

  9. Efficient growth of HTS films with volatile elements

    DOEpatents

    Siegal, M.P.; Overmyer, D.L.; Dominguez, F.

    1998-12-22

    A system is disclosed for applying a volatile element-HTS layer, such as Tl-HTS, to a substrate in a multiple zone furnace, said method includes heating at higher temperature, in one zone of the furnace, a substrate and adjacent first source of Tl-HTS material, to sublimate Tl-oxide from the source to the substrate; and heating at lower temperature, in a separate zone of the furnace, a second source of Tl-oxide to replenish the first source of Tl-oxide from the second source. 3 figs.

  10. Efficient growth of HTS films with volatile elements

    DOEpatents

    Siegal, Michael P.; Overmyer, Donald L.; Dominguez, Frank

    1998-01-01

    A system for applying a volatile element-HTS layer, such as Tl-HTS, to a substrate in a multiple zone furnace, said method includes heating at higher temperature, in one zone of the furnace, a substrate and adjacent first source of Tl-HTS material, to sublimate Tl-oxide from the source to the substrate; and heating at lower temperature, in a separate zone of the furnace, a second source of Tl-oxide to replenish the first source of Tl-oxide from the second source.

  11. Prospects of long-distance HTS DC power transmission systems

    NASA Astrophysics Data System (ADS)

    Romashov, M. A.; Sytnikov, V. E.; Shakarian, Y. G.; Ivanov, Y. V.

    2014-05-01

    Continual improvement of technologies for the safe use of power resources is a key to sustainable development of a human society. In particular, high-temperature superconductivity (HTS) should be used to meet the growing needs of the electric-power industry. It is known that HTS power cables allow us to increase the level of transmitted energy to several GW at voltage of 66-110 kV. HTS power cables of a coaxial design are almost ideal non-polluting system shielding electromagnetic field. In the present work we have tried to analyze various configurations of HTS power transmission systems, estimate the cable transmission capacitance depending on distance, and characterize reliability and efficiency of the systems.

  12. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  13. HTS thin films: Passive microwave components and systems integration issues

    NASA Technical Reports Server (NTRS)

    Miranda, F. A.; Chorey, C. M.; Bhasin, K. B.

    1995-01-01

    The excellent microwave properties of the High-Temperature-Superconductors (HTS) have been amply demonstrated in the laboratory by techniques such as resonant cavity, power transmission and microstrip resonator measurements. The low loss and high Q passive structures made possible with HTS, present attractive options for applications in commercial, military and spacebased systems. However, to readily insert HTS into these systems improvement is needed in such areas as repeatability in the deposition and processing of the HTS films, metal-contact formation, wire bonding, and overall film endurance to fabrication and assembly procedures. In this paper we present data compiled in our lab which illustrate many of the problems associated with these issues. Much of this data were obtained in the production of a space qualified hybrid receiver-downconverter module for the Naval Research Laboratory's High Temperature Superconductivity Space Experiment 2 (HTSSE-2). Examples of variations observed in starting films and finished circuits will be presented. It is shown that under identical processing the properties of the HTS films can degrade to varying extents. Finally, we present data on ohmic contacts and factors affecting their adhesion to HTS films, strength of wire bonds made to such contacts, and aging effects.

  14. HTS thin films: Passive microwave components and systems integration issues

    SciTech Connect

    Miranda, F.A.; Chorey, C.M.; Bhasin, K.B.

    1994-12-31

    The excellent microwave properties of the High-Temperature-Superconductors (HTS) have been amply demonstrated in the laboratory by techniques such as resonant cavity, power transmission and microstrip resonator measurements. The low loss and high Q passive structures made possible with HTS, present attractive options for applications in commercial, military and space-based systems. However, to readily insert HTS into these systems improvement is needed in such areas as repeatability in the deposition and processing of the HTS films, metal-contact formation, wire bonding, and overall film endurance to fabrication and assembly procedures. In this paper we present data compiled in our lab which illustrate many of the problems associated with these issues. Much of this data were obtained in the production of a space qualified hybrid receiver-downconverter module for the Naval Research Laboratory`s High Temperature Superconductivity Space Experiment II (HTSSE-II). Examples of variations observed in starting films and finished circuits will be presented. It is shown that under identical processing the properties of the HTS films can degrade to varying extents. Finally, we present data on ohmic contacts and factors affecting their adhesion to HTS films, strength of wire bonds made to such contacts, and aging effects.

  15. HTS Thin Films: Passive Microwave Components and Systems Integration Issues

    NASA Technical Reports Server (NTRS)

    Miranda, F. A.; Chorey, C. M.; Bhasin, K. B.

    1995-01-01

    The excellent microwave properties of the High-Temperature-Superconductors (HTS) have been amply demonstrated in the laboratory by techniques such as resonant cavity, power transmission and microstrip resonator measurements. The low loss and high Q passive structures made possible with HTS, present attractive options for applications in commercial, military and space-based systems. However, to readily insert HTS into these systems, improvement is needed in such areas as repeatability in the deposition and processing of the HTS films, metal-contact formation, wire bonding, and overall film endurance to fabrication and assembly procedures. In this paper, we present data compiled in our lab which illustrate many of the problems associated with these issues. Much of this data were obtained in the production of a space qualified hybrid receiver-downconverter module for the Naval Research Laboratory's High Temperature Superconductivity Space Experiment II (HTSSE-II). Examples of variations observed in starting films and finished circuits will be presented. It is shown that under identical processing the properties of the HTS films can degrade to varying extents. Finally, we present data on ohmic contacts and factors affecting their adhesion to HTS films, strength of wire bonds made to such contacts, and aging effects.

  16. Rotor compound concept for designing an industrial HTS synchronous motor

    NASA Astrophysics Data System (ADS)

    Kashani, M.; Hosseina, M.; Sarrafan, K.; Darabi, A.

    2013-06-01

    Recently, producing power with smaller amount of losses become as a goal in our daily life. Today, large amount of energy waste in power networks all around the world. The main reason is “resistive electric equipments” of power networks. Since early 1980s, simultaneous with the development of high temperature superconductive (HTS) technology, superconductors gently attracted the mankind attentions. Using superconductive equipments instead of conventional resistive ones are result in salient electric loss reduction in power systems. Especially to reduce losses in power networks superconductive industrial rotating machines can potentially perform a significant role. In early recent century, first generation of HTS rotating machines was born. But unfortunately they have long way to penetrate the commercial markets yet. In HTS rotating machines the conventional copper made windings are replaced with the HTS superconductors. In this paper an industrial HTS synchronous motor with YBCO coated conductor field windings was designed. As a new approach, model was equipped with a compound rotor that includes both magnetic and non-magnetic materials. So, large amount of heavy iron made part was replaced by light non-magnetic material such as G-10 fiberglass. Furthermore, in this structure iron loss in rotor could be reduced to its lowest value. Also less weight and more air gap energy density were the additional advantages. Regarding zero electric loss production in field windings and less iron loss in rotor construction, this model potentially is more effective than the other iron made HTS motors.

  17. Magnetic evaluation of advanced metal-evaporated tape in an advanced linear tape drive

    NASA Astrophysics Data System (ADS)

    Alfano, Anthony D.; Bhushan, Bharat

    2007-01-01

    Demand for increased data storage has resulted in the development of various types of magnetic tapes. To achieve higher recording density, tape manufacturers are developing thin-film tapes, such as advanced metal-evaporated (AME) tape, for use in linear tape drives. In recent studies, these new AME tapes have demonstrated sustainable mechanical durability at low tensions suitable for use in linear tape drives. An evaluation of the magnetic performance of these AME tapes including the impact of tape cupping and initial edge quality was the goal of this study. Head output, dropouts, head-tape interface friction, and lateral tape motion (LTM) were monitored throughout testing. As track widths continue to narrow, LTM has become one of the critical limitations of magnetic performance. To more accurately measure LTM during drive development, a new method involving the output voltage of a head-read element that has been adjusted to be halfway off the recorded track on tape was implemented (LTM M). It is shown that positively cupped AME tapes will result in similar head output and fewer dropouts than the current MP tapes. The negatively cupped AME sample produced the lowest head output data and the highest amount of dropouts of all the tapes evaluated in this investigation. All the tapes evaluated demonstrated similar values of LTM when monitored at the center of the tape. When LTM was monitored at the lower edge of the tape, the positively cupped AME tape with the worst relative edge contour length resulted in the highest LTM M. As found in previous studies, AME tapes produced slightly lower values of coefficient of friction than the MP tapes. From this investigation, positively cupped AME tapes with good initial relative edge contour length are recommended for use in linear tape drives, similar to those used in this study.

  18. Tape edge study in a linear tape drive with single-flanged guides

    NASA Astrophysics Data System (ADS)

    Goldade, Anton V.; Bhushan, Bharat

    2004-05-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge.

  19. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  20. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  1. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  2. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  3. Development of HTS magnets for application

    NASA Astrophysics Data System (ADS)

    Hatanaka, Kichiji; Fukuda, Mitsuhiro; Yorita, Tetsuhiko; Ueda, Hiroshi; Yasuda, Yuusuke; Kamakura, Keita; Morita, Yoshiya; Yamane, Hiroyoshi; Kawaguchi, Takeo

    2014-09-01

    We have been developing magnets utilizing high-temperature superconducting (HTS) wires for this decade. We built three model magnets, a mirror coil for an ECR ion source, a set of coils for a scanning magnet and a super-ferric dipole magnet to generate magnetic field of 3 T. They were excited with AC/pulse currents as well as DC currents. Recently we fabricated a cylindrical magnet for a practical use which polarizes ultracold neutrons (UCN). It consists of 10 double pancakes and the field strength at the center is higher than 3.5 T which is required to fully polarize 210 neV neutrons. It was successfully cooled and excited. The magnet was used to polarized UCN generated by the RCNP-KEK superthermal UCN source, One dipole magnet has been manufactured which is used as a switching magnet after the RCNP ring cyclotron and is excited by pulse currents. It becomes possible to deliver beams to two experimental halls by time sharing. Their designs and performances are presented in the talk.

  4. A Study of Audio Tape: Part II

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    To evaluate reel audio tape, tests were performed to identify: signal-to-noise ratio, total harmonic distortion, dynamic response, frequency response, biased and virgin tape noise, dropout susceptibility and oxide coating uniformity. (SCC)

  5. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1983-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives guidelines for transcribing special formats such as typing books. The second article tells how to give verbal instructions for diagraming sentences and other…

  6. A Study of Audio Tape

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    This is part I of a report on a study comparing reel and cassette tapes for signal-to-noise ration, total harmonic distortion, dynamic response, frequency response, bias and virgin noise and oxide coating uniformity. Test equipment and procedures are described and results are discussed. Charts detail research findings. (CHK)

  7. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  8. MOD Buffer/YBCO Approach to Fabricate Low-Cost Second Generation HTS Wires

    SciTech Connect

    Paranthaman, Mariappan Parans; Sathyamurthy, Srivatsan; Bhuiyan, Md S; Martin, Patrick M; Aytug, Tolga; Kim, Kyunghoon; Fayek, Mostafa; Leonard, Keith J; Li, Jing; Zhang, W.; Rupich, Marty

    2007-01-01

    The metal organic deposition (MOD) of buffer layers on RABiTS substrates is considered a potential, low-cost approach to manufacturing high performance Second Generation (2G) high temperature superconducting (HTS) wires. The typical architecture used by American Superconductor in their 2G HTS wire consists of a Ni-W (5 at.%) substrate with a reactively sputtered Y2O3 seed layer, YSZ barrier layer and a CeO2 cap layer. This architecture supports critical currents of over 300 A/cm-width (77 K, self-field) with 0.8 mum YBCO films deposited by the TFA-MOD process. The main challenge in the development of the MOD buffers is to match or exceed the performance of the standard vacuum deposited buffer architecture. We have recently shown that the texture and properties of MOD - La2Zr2Ogamma (LZO) barrier layers can be improved by inserting a thin sputtered Y2O3 seed layer and prepared MOD deposited LZO layers followed by MOD or RF sputtered CeO2 cap layers that support MOD-YBCO films with Ic's of 200 and 255 A/cm-width, respectively. Detailed X-ray and microstructural characterizations indicated that MOD - CeO2 cap reacted completely with MOD YBCO to form BaCeOs. However, sputtered CeO2 cap/MOD YBCO interface remains clean. By further optimizing the coating conditions and reducing the heat-treatment temperatures, we have demonstrated an Ic of 336 A/cm with improved LZO layers and sputtered CeO2 cap and exceeded the performance of that of standard vacuum deposited buffers.

  9. Modelling ac ripple currents in HTS coated conductors

    NASA Astrophysics Data System (ADS)

    Xu, Zhihan; Grilli, Francesco

    2015-10-01

    Dc transmission using high temperature superconducting (HTS) coated conductors (CCs) offers a promising solution to the globally growing demand for effective, reliable and economic transmission of green energy up to the gigawatt level over very long distances. The credible estimation of the losses and thereby the heat dissipation involved, where ac ripples (introduced in rectification/ac-dc conversion) are viewed as a potential source of notable contribution, is highly essential for the rational design of practical HTS dc transmission cables and corresponding cryogenic systems to fulfil this demand. Here we report a targeted modelling study into the ac losses in a HTS CC subject to dc and ac ripple currents simultaneously, by solving Maxwell’s equations using the finite element method (FEM) in the commercial software package COMSOL. It is observed that the instantaneous loss exhibits only one peak per cycle in the HTS CC subject to sinusoidal ripples, given that the amplitude of the ac ripples is smaller than approximately 20% of that of the dc current. This is a distinct contrast to the usual observation of two peaks per cycle in a HTS CC subject to ac currents only. The unique mechanism is also revealed, which is directly associated with the finding that, around any local minima of the applied ac ripples, the critical state of -J c is never reached at the edges of the HTS CC, as it should be according to the Bean model. When running further into the longer term, it is discovered that the ac ripple loss of the HTS CC in full-wave rectification decays monotonically, at a speed which is found to be insensitive to the frequency of the applied ripples within our targeted situations, to a relatively low level of approximately 1.38 × 10-4 W m-1 in around 1.7 s. Comparison between this level and other typical loss contributions in a HTS dc cable implies that ac ripple currents in HTS CCs should only be considered as a minor source of dissipation in superconducting dc

  10. Analysis of cache for streaming tape drive

    NASA Astrophysics Data System (ADS)

    Chinnaswamy, V.

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  11. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  12. Comparison between HTS nonlinearities in patterned and unpatterned thin films

    NASA Astrophysics Data System (ADS)

    Mateu, Jordi; Collado, Carlos; O'Callaghan, Juan M.; Universitat Politecnica de Catalunya Team

    2004-03-01

    High Temperature Superconductor (HTS) materials exhibit a surface impedance dependence on the applied field. This behavior still remains not yet fully understood. To overcome this, many experiments have been carried out through the last decade. In general, the experimental work has been done measuring intermodulation products in patterned devices since most of practical devices are based on patterned structures. In this case the nonlinearities might come from many causes -- HTS properties, possible damage due to patterning, shape of resonator, etc.--, which need to be characterized. This raises the question of how representative of HTS properties are the experiments performed on patterned samples. To address this, we propose such a procedure, which is based on obtaining parameters describing the HTS nonlinearities from intermodulation measurements made on unpatterned and patterned thin films. As example, we have characterized the nonlinearities in a one side 10x10 mm^2 YBCO on MgO thin film by measuring the intermodulation products with a rutile-loaded cavity operating at TE_011 mode and a coplanar half-wave resonator. The intermodulation data in both type of measurements can be fitted using closed-form expressions and numerical techniques with identical nonlinear parameters of the HTS.

  13. Calibration of a HTS Based LOX 400 mm Level Sensor

    NASA Astrophysics Data System (ADS)

    Karunanithi, R.; Jacob, S.; Nadig, D. S.; Prasad, M. V. N.; Gour, Abhay S.; Pankaj, S.; Gowthaman, M.; Sudharshan, H.

    The measurement of the cryogen level in a cryostage of space crafts is crucial. At the same time the weight of the sensor should be small as it affects the payload fraction of the space craft. An attempt to develop a HTS based level sensor of 400 mm for Liquid Oxygen (LOX) measurement was made. In the initial phase of testing, loss of superconductivity of HTS wire in LOX inside a cryostat was noticed. Thus, a new four wall cryostat was designed to have a stable LOX level to provide thermal stability to the HTS based LOX sensor. The calibration of the developed sensor was carried out against capacitance level sensor which was pre calibrated using diode array to verify its linearity and performance for different current excitation levels. The calibrations were carried out without heater wires. The automatic data logging was accomplished using a program developed in LabVIEW 11.0.

  14. Levitation force relaxation under reloading in a HTS Maglev system

    NASA Astrophysics Data System (ADS)

    He, Qingyong; Wang, Jiasu; Wang, Suyu; Wang, Jiansi; Dong, Hao; Wang, Yuxin; Shao, Senhao

    2009-02-01

    The loading capacity of the high-temperature superconducting (HTS) Maglev vehicle is an important parameter in the practical application. It is closely related to the levitation force of the HTS bulk. Many papers reported that the levitation force showed the relaxation characteristic. Because different loads cause different levitation gaps and different applied magnetic fields, the levitation force relaxations under the different loads are not the same. In terms of cylindrical YBCO bulk levitated over the permanent magnetic guideway, the relationship between the levitation force relaxation and the reloading is investigated experimentally in this paper. The decrement, the decrement rate and the relaxation rate of the levitation force are calculated, respectively. This work might be helpful for studying the loading capacity of the HTS Maglev vehicle.

  15. HTS power lead testing at the Fermilab magnet test facility

    SciTech Connect

    Rabehl, R.; Carcagno, R.; Feher, S.; Huang, Y.; Orris, D.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.; /Fermilab

    2005-08-01

    The Fermilab Magnet Test Facility has tested high-temperature superconductor (HTS) power leads for cryogenic feed boxes to be placed at the Large Hadron Collider (LHC) interaction regions and at the new BTeV C0 interaction region of the Fermilab Tevatron. A new test facility was designed and operated, successfully testing 20 pairs of HTS power leads for the LHC and 2 pairs of HTS power leads for the BTeV experiment. This paper describes the design and operation of the cryogenics, process controls, data acquisition, and quench management systems. Results from the facility commissioning are included, as is the performance of a new insulation method to prevent frost accumulation on the warm ends of the power leads.

  16. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  17. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate...

  18. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  19. High density tape casting system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1989-01-01

    A system is provided for casting thin sheets (or tapes) of particles bound together, that are used for oxygen membranes and other applications, which enables the particles to be cast at a high packing density in a tape of uniform thickness. A slurry contains the particles, a binder, and a solvent, and is cast against the inside walls of a rotating chamber. Prior to spraying the slurry against the chamber walls, a solvent is applied to a container. The solvent evaporates to saturate the chamber with solvent vapor. Only then is the slurry cast. As a result, the slurry remains fluid long enough to spread evenly over the casting surface formed by the chamber, and for the slurry particles to become densely packed. Only then is the chamber vented to remove solvent, so the slurry can dry. The major novel feature is applying solvent vapor to a rotating chamber before casting slurry against the chamber walls.

  20. Protein crystallization: from HTS to kilogram-scale.

    PubMed

    Klyushnichenko, Vadim

    2003-11-01

    The first experiments on protein crystallization started randomly during the 19th century. This technique has been widely used for the determination of the tertiary structure of proteins since the 1950s, when an understanding of the physics of protein crystallization began to emerge. In the 1980s and 1990s, research focused on the study of protein crystal growth processes in microgravity environments, which were created in space shuttle experiments. High-throughput screening (HTS) systems were developed that later found broader laboratory applications. The combination of HTS with an engineering approach opens new opportunities for the protein crystallization process to become a robust, scalable, reproducible and economically viable industrial unit operation.

  1. Development of a 600 kJ HTS SMES

    NASA Astrophysics Data System (ADS)

    Seong, K. C.; Kim, H. J.; Kim, S. H.; Sim, K. D.; Sohn, M. H.; Lee, E. Y.; Park, S. J.; Hahn, S. Y.; Park, M. W.

    2008-09-01

    This paper describes an overview of development on a 600 kJ high-temperature superconducting magnetic energy storage (HTS SMES). Our final goal will be the commercialization of MJ class HTS SMES system for the increase of power quality within 5 years. Hence, for this purpose, we have developed the research and development in 3 years. The purpose of this research is to develop a pilot system, which can protect the sensitivity loads from a momentary power interruption or a voltage sag.

  2. Quench detection system for twin coils HTS SMES

    NASA Astrophysics Data System (ADS)

    Badel, A.; Tixador, P.; Simiand, G.; Exchaw, O.

    2010-10-01

    The quench detection and protection system is a critical element in superconducting magnets. After a short summary of the quench detection and protection issues in HTS magnets, an original detection system is presented. The main feature of this system is an active protection of the detection electronics during the discharges, making it possible to use standard electronics even if the discharge voltage is very high. The design of the detection system is therefore easier and it can be made very sensitive. An implementation example is presented for a twin coil HTS SMES prototype, showing the improvements when compared to classical detection systems during operation.

  3. Test Results for a 25 Meter Prototype Fault Current Limiting Hts Cable for Project Hydra

    NASA Astrophysics Data System (ADS)

    Rey, C. M.; Duckworth, R. C.; Demko, J. A.; Ellis, A.; James, D. R.; Gouge, M. J.; Tuncer, E.

    2010-04-01

    The Oak Ridge National Laboratory (ORNL) has tested a 25-m long prototype High Temperature Superconducting (HTS) cable with inherent Fault-Current Limiting (FCL) capability at its HTS cable test facility. The HTS-FCL cable and terminations were designed and fabricated by Ultera, which is a joint venture between Southwire and nkt cables. System integration and HTS wire were provided by American Superconductor Corporation who was the overall team leader of the project. The ultimate goal of the 25-m HTS-FCL cable test program was to verify the design and ensure the operational integrity for the eventual installation of a ˜200-m fully functional HTS-FCL cable in the Consolidated Edison electric grid located in downtown New York City. The 25-m HTS-FCL cable consisted of a three-phase (3-Φ) HTS Triax™ design with a cold dielectric between the phases. The HTS-FCL cable had an operational voltage of 13.8 kV phase-to-phase (7967 V phase-to-ground) and an operating current of 4000 Arms per phase, which is the highest operating current to date of any HTS cable. The 25-m HTS-FCL cable was subjected to a series of cryogenic and electrical tests. Test results from the 25-m HTS-FCL cable are presented and discussed.

  4. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  5. Experimental studies of helical solenoid model based on YBCO tape-bridge joints

    SciTech Connect

    Yu, M.; Lombardo, V.; Turrioni, D.; Zlobin, A.V.; Flangan, G.; Lopes, M.L.; Johnson, R.P.; /Fermilab

    2011-06-01

    Helical solenoids that provide solenoid, helical dipole and helical gradient field components are designed for a helical cooling channel (HCC) proposed for cooling of muon beams in a muon collider. The high temperature superconductor (HTS), 12 mm wide and 0.1 mm thick YBCO tape, is used as the conductor for the highest-field section of HCC due to certain advantages, such as its electrical and mechanical properties. To study and address the design, and technological and performance issues related to magnets based on YBCO tapes, a short helical solenoid model based on double-pancake coils was designed, fabricated and tested at Fermilab. Splicing joints were made with Sn-Pb solder as the power leads and the connection between coils, which is the most critical element in the magnet that can limit the performance significantly. This paper summarizes the test results of YBCO tape and double-pancake coils in liquid nitrogen and liquid helium, and then focuses on the study of YBCO splices, including the soldering temperatures and pressures, and splice bending test.

  6. Large-scale HTS bulks for magnetic application

    NASA Astrophysics Data System (ADS)

    Werfel, Frank N.; Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter

    2013-01-01

    ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN2 and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500-3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN2 allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved.

  7. HTS DC Transmission Line for Megalopolis Grid Development

    NASA Astrophysics Data System (ADS)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  8. Characteristics on electodynamic suspension simulator with HTS levitation magnet

    NASA Astrophysics Data System (ADS)

    Lee, J.; Bae, D. K.; Sim, K.; Chung, Y. D.; Lee, Y.-S.

    2009-10-01

    High- Tc superconducting (HTSC) electrodynamic suspension (EDS) system basically consists of the HTSC levitation magnet and the ground conductor. The levitation force of EDS system is forms by the interaction between the moving magnetic field produced by the onboard levitation magnet and the induced magnetic field produced by eddy current in the ground conductor. This paper deals with the characteristics of the EDS simulators with high- Tc superconducting (HTS) levitation magnet. Two EDS simulator systems, rotating type EDS simulator and static type EDS simulator, were studied in this paper. The rotating type EDS simulator consists of a HTS levitation magnet and a 1.5 m diameter rotating ground conductor, a motor, the supporting structure and force measuring devices. In the static type EDS simulator, instead of moving magnetic field, AC current was applied to the fixed HTS levitation magnet to induce the eddy current. The static type EDS simulator consists of a HTS levitation magnet, a ground conductor, force measuring devices and supporting structure. The double-pancake type HTSC levitation magnet was designed, manufactured and tested in the EDS simulator.

  9. Numerical assessment of efficiency and control stability of an HTS synchronous motor

    NASA Astrophysics Data System (ADS)

    Xian, Wei; Yuan, Weijia; Coombs, T. A.

    2010-06-01

    A high temperature superconducting (HTS) permanent magnet synchronous motor (PMSM) is designed and developed in Cambridge University. It is expected to become cost competitive with the conventional PMSM owing to its high efficiency, high power density, high torque density, etc. The structure and parameters of HTS PMSM are detailed. Both AC losses by transport current and applied filed in stator armature winding of HTS PMSM are also analyzed. Computed and simulated results of the characteristics of the HTS PMSM and conventional PMSM are compared. The improvement on stability of direct torque control (DTC) on the HTS PMSM is estimated, and proved by simulation on Matlab/Simulink.

  10. Investigation of current transport normal and parallel to the tape plane in BSCCO/Ag tapes

    SciTech Connect

    Maley, M.P.; Cho, J.H.; Willis, J.O.; Bulaevskii, L.N.

    1995-07-01

    We have performed transport, resistivity and critical current measurements on Bi-2223/Ag and Bi-2212/Ag tapes with current directions both parallel and perpendicular to the tape plane in magnetic fields up to 7 T and 50tape normal (nominal c-axis in a textured tape) is metallic, scales with the inplane resistivity at all fields and is dramatically reduced from single crystal c-axis values. Similarly, the critical current along the tape normal exhibits magnetic field and field orientation dependences similar to those for current flow along the tape plane. These results indicate that current flow along CuO{sub 2} planes dominates current transport even along the tape normal in highly textured tapes.

  11. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  12. Structure of human ubiquitin-conjugating enzyme E2 G2 (UBE2G2/UBC7)

    SciTech Connect

    Arai, Ryoichi; Yoshikawa, Seiko; Murayama, Kazutaka; Imai, Yuzuru; Takahashi, Ryosuke; Shirouzu, Mikako; Yokoyama, Shigeyuki

    2006-04-01

    The crystal structure of human UBE2G2/UBC7 was solved at 2.56 Å resolution. The superimposition of UBE2G2 on UbcH7 in a c-Cbl–UbcH7–ZAP70 ternary complex suggested that the two loop regions of UBE2G2 interact with the RING domain in a similar way as UbcH7. The human ubiquitin-conjugating enzyme E2 G2 (UBE2G2/UBC7) is involved in protein degradation, including a process known as endoplasmic reticulum-associated degradation (ERAD). The crystal structure of human UBE2G2/UBC7 was solved at 2.56 Å resolution. The UBE2G2 structure comprises a single domain consisting of an antiparallel β-sheet with four strands, five α-helices and two 3{sub 10}-helices. Structural comparison of human UBE2G2 with yeast Ubc7 indicated that the overall structures are similar except for the long loop region and the C-terminal helix. Superimposition of UBE2G2 on UbcH7 in a c-Cbl–UbcH7–ZAP70 ternary complex suggested that the two loop regions of UBE2G2 interact with the RING domain in a similar way to UbcH7. In addition, the extra loop region of UBE2G2 may interact with the RING domain or its neighbouring region and may be involved in the binding specificity and stability.

  13. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    SciTech Connect

    Selvamanickam, V; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Yao, Y; Xiong, X; Lei, C; Soloveichik, S; Galstyan, E; Majkic, G

    2013-01-21

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12 mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  14. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Chen, Y.; Shi, T.; Liu, Y.; Khatri, N. D.; Liu, J.; Yao, Y.; Xiong, X.; Lei, C.; Soloveichik, S.; Galstyan, E.; Majkic, G.

    2013-03-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm-2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m-3. The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  15. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  16. Pocket-size manual tape reader device aids computer tape checking

    NASA Technical Reports Server (NTRS)

    Odle, F. L.

    1967-01-01

    Pocket-size plastic manual tape reader device aids in reading, interpreting, and correcting binary and octal coded punched tapes. The coded information is more easily read if the color of the back plate contrasts sharply with that of the tape.

  17. Critical currents of YBCO tapes and Bi-2212 wires at different temperatures and magnetic fields

    SciTech Connect

    Lombardo, V.; Barzi, e.; Turrioni, D.; Zlobin, A.V.; /Fermilab

    2010-08-01

    Design studies for the cooling channel of a Muon Collider call for straight and helical solenoids generating field well in excess of the critical fields of state of the art Low Temperature Superconductors (LTS) such as Nb{sub 3}Sn or NbTi. Therefore, High Temperature Superconductors (HTS) will need to be used for the manufacturing of all or certain sections of such magnets to be able to generate and withstand the field levels at the cryogenic temperatures required by the new machine. In this work, two major High Temperature Superconductors - Bi2212 round wires and YBCO coated conductor tapes - are investigated to understand how critical current density of such conductors scales as a function of external field and operating temperature. This is vital information to make conductor choices depending on the application and to proceed with the design of such magnets.

  18. Axial ligand replacement mechanism in heme transfer from streptococcal heme-binding protein Shp to HtsA of the HtsABC transporter.

    PubMed

    Ran, Yanchao; Malmirchegini, G Reza; Clubb, Robert T; Lei, Benfang

    2013-09-17

    The heme-binding protein Shp of Group A Streptococcus rapidly transfers its heme to HtsA, the lipoprotein component of the HtsABC transporter, in a concerted two-step process with one kinetic phase. Heme axial residue-to-alanine replacement mutant proteins of Shp and HtsA (Shp(M66A), Shp(M153A), HtsA(M79A), and HtsA(H229A)) were used to probe the axial displacement mechanism of this heme transfer reaction. Ferric Shp(M66A) at high pH and Shp(M153A) have a pentacoordinate heme iron complex with a methionine axial ligand. ApoHtsA(M79A) efficiently acquires heme from ferric Shp but alters the reaction mechanism to two kinetic phases from a single phase in the wild-type protein reactions. In contrast, apoHtsA(H229A) cannot assimilate heme from ferric Shp. The conversion of pentacoordinate holoShp(M66A) into pentacoordinate holoHtsA(H229A) involves an intermediate, whereas holoHtsA(H229A) is directly formed from pentacoordinate holoShp(M153A). Conversely, apoHtsA(M79A) reacts with holoShp(M66A) and holoShp(M153A) in mechanisms with one and two kinetic phases, respectively. These results imply that the Met79 and His229 residues of HtsA displace the Met66 and Met153 residues of Shp, respectively. Structural docking analysis supports this mechanism of the specific axial residue displacement. Furthermore, the rates of the cleavage of the axial bond in Shp in the presence of a replacing HtsA axial residue are greater than that in the absence of a replacing HtsA axial residue. These findings reveal a novel heme transfer mechanism of the specific displacement of the Shp axial residues with the HtsA axial residues and the involvement of the HtsA axial residues in the displacement.

  19. Towards G2G: Systems of Technology Database Systems

    NASA Technical Reports Server (NTRS)

    Maluf, David A.; Bell, David

    2005-01-01

    We present an approach and methodology for developing Government-to-Government (G2G) Systems of Technology Database Systems. G2G will deliver technologies for distributed and remote integration of technology data for internal use in analysis and planning as well as for external communications. G2G enables NASA managers, engineers, operational teams and information systems to "compose" technology roadmaps and plans by selecting, combining, extending, specializing and modifying components of technology database systems. G2G will interoperate information and knowledge that is distributed across organizational entities involved that is ideal for NASA future Exploration Enterprise. Key contributions of the G2G system will include the creation of an integrated approach to sustain effective management of technology investments that supports the ability of various technology database systems to be independently managed. The integration technology will comply with emerging open standards. Applications can thus be customized for local needs while enabling an integrated management of technology approach that serves the global needs of NASA. The G2G capabilities will use NASA s breakthrough in database "composition" and integration technology, will use and advance emerging open standards, and will use commercial information technologies to enable effective System of Technology Database systems.

  20. TReqS: The Tape REQuest Scheduler

    NASA Astrophysics Data System (ADS)

    Schaeffer, Jonathan; Gómez Casanova, Andrés

    2011-12-01

    TReqS is a new layer in the storage infrastructure at CCIN2P3 controlling the read operations for data stored on tapes in HPSS (a HSM) by centralizing all requests. The development and deployment of TReqS at CCIN2P3 has brought major advances in data access services on several aspects. First, by sorting and scheduling tape mounts, we radically reduce the waiting time due to media movements in the tape library. Second, in a mutualised environment where tape drives are globally available to all users, TReqS ensures the fair share of the drives. Finaly, TReqS softens the impact of unpredictable grid jobs and transfers on the actual tape library and efficiently masks the data access complexity to the end user.

  1. Pollution prevention in the magnetic tape industry: Waterborne coating formulations for video tape manufacture

    SciTech Connect

    Cheng, S.; Fan, H.; Gogineni, N.; Jacobs, B.; Harrell, J.W.; Jefcoat, I.A.; Lane, A.M.; Nikles, D.E.

    1995-12-31

    A waterborne magnetic tape coating formulation was designed and used to prepare experimental magnetic tape samples in a pilot coating trial. The formulations contained a blend of a water-dispersed polyester and an ethylene/vinyl chloride copolymer emulsion, cross-linked with melamine-formaldehyde to give tensile properties (tensile strength 8.69 MPa Young`s modulus 245 MPa) that were comparable to a standard solvent-based binder composition. The pilot tape trial used existing processing equipment, including calendering and slitting. The tape had good magnetic properties and excellent adhesion between the pigmented magnetic layer and the base film, easily exceeding the 8 mm helical scan tape standard of 0.96 N peel force. An economic impact analysis for the case of sing the waterborne video tape coating process in a conventional tape manufacturing plant showed a significant decrease in costs for adopting the waterborne process.

  2. HTS Fabry-Perot resonators for the far infrared

    NASA Astrophysics Data System (ADS)

    Keller, Philipp; Prenninger, Martin; Pechen, Evgeny V.; Renk, Karl F.

    1996-06-01

    We report on far infrared (FIR) Fabry-Perot resonators (FPR) with high temperature superconductor (HTS) thin films as mirrors. For the fabrication of FPR we use two parallel MgO plates covered with YBa2Cu3O7-delta thin films on adjacent sides. We have measured the far-infrared transmissivity at 10 K with a Fourier transform infrared spectrometer. Very sharp resonances can be observed for frequencies below 6 THz where the MgO is transparent. The finesse (width of the first order resonance) is comparable to the FPR with metallic meshes as reflectors that are applied in the FIR spectroscopy and astronomy. We have also shown that thin films of gold are not adequate substitute to HTS thin films and not suitable for the fabrication of high-quality FPR due to the ohmic losses.

  3. High voltage insulation of bushing for HTS power equipment

    NASA Astrophysics Data System (ADS)

    Kim, Woo-Jin; Choi, Jae-Hyeong; Kim, Sang-Hyun

    2012-12-01

    For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. Liquid nitrogen (LN2) is an attractive dielectric liquid. Also, the polymer insulating materials are expected to be used as solid materials such as glass fiber reinforced plastic (GFRP), polytetra-fluoroethylene (PTFE, Teflon), Silicon (Si) rubber, aromatic polyamide (Nomex), EPDM/Silicon alloy compound (EPDM/Si). In this paper, the surface flashover characteristics of various insulating materials in LN2 are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The use of GFRP and Teflon as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in LN2 and operation of superconducting equipments.

  4. Mechanical stabilization of BSCCO-2223 superconducting tapes

    SciTech Connect

    King, C.G.; Grey, D.A.; Mantone, A.

    1996-12-31

    A system to provide mechanical stabilization to high temperature BSCCO-2223 superconducting tape by laminating 0.081 mm thick, spring hard, copper foil to both sides with lead-tin eutectic solder has been successfully optimized. This system has been applied as a method to create a strong, windable composite from pure silver BSCCO tapes with a minimum of critical current (I{sub c}) degradation. The {open_quotes}as received{close_quotes} conductor is evaluated for physical consistency of width and thickness over the 3000 meters that were later strengthened, insulated and wound into a demonstration coil. Electrical degradation in the strengthened tape as a result of lamination was found to average 24 percent with a range from 4 to 51 percent. This was less than the degradation that would have occurred in an unstrengthened tape during subsequent insulation and coil winding processes. Additional work was performed to evaluate the mechanical properties of the strengthened tapes. The copper can double the ultimate tensile strength of the pure silver tapes. Additionally, pure silver and dispersion strengthened silver matrix tapes are laminated with 0.025 mm thick copper and 304 stainless steel foil to investigate minimization of the cross sectional area of the strengthening component. The stainless steel can increase the UTS of the pure silver tapes sixfold. Metallography is used to examine the laminate and the conductor. Mechanical properties and critical currents of these tapes are also reported both before and after strengthening. The I{sub c} is also measured as a function of strain on the laminated tapes.

  5. Demonstration project cuts red tape

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    Results from a demonstration project aimed at cutting red tape in federal grants for basic research at universities are "very encouraging" so far, according to Don I. Phillips, executive director of the Government-University-Industry Research Roundtable. The roundtable is coordinating the experimental effort, with the participation of five major federal agencies as well as the Florida state university system and the University of Miami (a private institution in Coral Gables, Fla.).Under the project, special conditions apply to grants from the participating agencies to individual researchers at the participating universities: Investigators do not have to ask the agency's permission for changes in budget allocations, purchases of permanent equipment, or foreign travel. Grant money can be spent up to a year after the grant ends without a special request. Under this plan, researchers, with agency approval, can also ask to have their entire research program covered as a single administrative entity, rather than as several individual projects.

  6. QRNT: A primary thermometer based on an HTS SQUID

    NASA Astrophysics Data System (ADS)

    Gallop, John; Hao, Ling; Reed, Richard

    1997-08-01

    We propose a novel form of cryogenic primary thermometer based on flux quantisation in a HTS superconducting ring, interrupted by a Josephson junction which we call the Quantum Roulette Noise Thermometer (QRNT). Unlike other superconductivity-based noise thermometers this device is essentially dissipationless, requires no input or output connections and may be remotely interrogated. The QRNT has the potential to provide high accuracy with short measuring times.

  7. Application of HTS technology to cardiac dysrhythmia detection

    SciTech Connect

    Sobel, A.L.; Avrin, W.F.

    1994-12-01

    This paper discusses the conceptual design considerations and challenges for development of a contactless, mobile, single channel biomagnetic sensor system based on High-Temperature Superconductor (HTS) Superconducting Quantum Interference Devices (SQUIDs) and employing the Three-SQUID Gradiometer (TSG) concept. Operating in magnetically unshielded environments, as are encountered in many medical scenarios, this instrument class would monitor cardiac electrical activity with minimal patient preparation and intrusiveness, and would notionally be coupled with a clinically adaptive human-system interface (HSI).

  8. Thermodynamic Study of UO3(g), UO2(OH)2(g), UO2Cl2(g), and UO2F2(g)

    SciTech Connect

    Ebbinghaus, B B; Krikorian, O H; Fleming, D L

    2002-11-07

    Using the transpiration method, the volatility of uranium oxide in the presence of oxygen and water vapor has been measured at temperatures ranging from 1173 to 1573 K and the volatility of uranium oxide in the presence of oxygen and chlorine has been measured at 1175 K. The major vapor species in the presence of oxygen and water vapor are found to be UO{sub 3}(g) and UO{sub 2}(0H){sub 2}(g). Third law treatment of the vaporization data yields {Delta}H{sub f}{sup o}(298) values of -790.52 {+-} 7.32 and -1199.94 {+-} 10.25 kJ/mol, respectively. The major vapor species in the presence of oxygen and chlorine is found to be UO{sub 2}Cl{sub 2}(g). Third law treatment of the vaporization data yields a {Delta}H{sub f}{sup o}(298) value of -1002.04 {+-} 3.26 kJ/mol. From an assessment of all the thermodynamic data available for UO{sub 3}(g), UO{sub 2}(OH){sub 2}(g), UO{sub 2}Cl{sub 2}(g), and UO{sub 2}F{sub 2}(g), the best {Delta}H{sub f{sup o}}(298) values for each of these species are calculated to be -796.74 {+-} 3.52, -1199.94 {+-} 10.25, -999.64 {+-} 2.40, and -1369.22 {+-} 2.87 kJ/mol, respectively. From these, the {Delta}H{sub f{sup o}} (298) values for UO{sub 2}ClOH(g), UO{sub 2}FOH(g), and UO{sub 2}FCl(g) are estimated to be -1099.79, -1284.58, and -1184.43 kJ/mol, respectively. The thermodynamic data for all the vapor species are then applied to conditions one might expect in a thermal oxidation processor for mixed waste to estimate the amount of uranium volatility.

  9. Development of advanced barium ferrite tape media

    NASA Astrophysics Data System (ADS)

    Shimizu, Osamu; Oyanagi, Masahito; Morooka, Atsushi; Mori, Masahiko; Kurihashi, Yuich; Tada, Toshio; Suzuki, Hiroyuki; Harasawa, Takeshi

    2016-02-01

    We developed an advanced particulate magnetic tape using fine barium ferrite (BaFe) particles for magnetic-tape storage systems. The new tape showed a signal-to-noise ratio (SNR) that was 3.5 dB higher than that of the commercially available BaFe tape used for the Linear Tape Open generation 6 tape-storage system, at a linear density of 300 kfci measured with a giant magnetoresistive head with a reader width of 0.45 μm. Such significant increase in SNR was achieved by reducing the magnetic particle volume from 1950 to 1350 nm3, while maintaining a sufficiently high thermal stability, improving the perpendicular squareness ratio from 0.66 to 0.83, and improving the surface roughness from 2.5 to 2.0 nm when measured by atomic force microscopy and from 2.4 to 0.9 nm when measured by optical interferometry. This paper describes the characteristics of the new BaFe particles and media, which are expected to be employed for future high-capacity linear-tape systems.

  10. From Ions to Wires to the Grid: The Transformational Science of LANL Research in High-Tc Superconducting Tapes and Electric Power Applications

    SciTech Connect

    Marken, Ken

    2009-05-20

    The Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) has been tasked to lead national efforts to modernize the electric grid, enhance security and reliability of the energy infrastructure, and facilitate recovery from disruptions to energy supplies. LANL has pioneered the development of coated conductors – high-temperature superconducting (HTS) tapes – which permit dramatically greater current densities than conventional copper cable, and enable new technologies to secure the national electric grid. Sustained world-class research from concept, demonstration, transfer, and ongoing industrial support has moved this idea from the laboratory to the commercial marketplace.

  11. From Ions to Wires to the Grid: The Transformational Science of LANL Research in High-Tc Superconducting Tapes and Electric Power Applications

    SciTech Connect

    Marken, Ken

    2009-05-20

    The Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) has been tasked to lead national efforts to modernize the electric grid, enhance security and reliability of the energy infrastructure, and facilitate recovery from disruptions to energy supplies. LANL has pioneered the development of coated conductors - high-temperature superconducting (HTS) tapes - which permit dramatically greater current densities than conventional copper cable, and enable new technologies to secure the national electric grid. Sustained world-class research from concept, demonstration, transfer, and ongoing industrial support has moved this idea from the laboratory to the commercial marketplace.

  12. From Ions to Wires to the Grid: The Transformational Science of LANL Research in High-Tc Superconducting Tapes and Electric Power Applications

    ScienceCinema

    Marken, Ken [Superconductivity Technology Center, Los Alamos, New Mexico, United States

    2016-07-12

    The Department of Energy (DOE) Office of Electricity Delivery and Energy Reliability (OE) has been tasked to lead national efforts to modernize the electric grid, enhance security and reliability of the energy infrastructure, and facilitate recovery from disruptions to energy supplies. LANL has pioneered the development of coated conductors – high-temperature superconducting (HTS) tapes – which permit dramatically greater current densities than conventional copper cable, and enable new technologies to secure the national electric grid. Sustained world-class research from concept, demonstration, transfer, and ongoing industrial support has moved this idea from the laboratory to the commercial marketplace.

  13. Test results of a HTS power transformer connected to a power grid

    NASA Astrophysics Data System (ADS)

    Kimura, H.; Honda, K.; Hayashi, H.; Tsutsumi, K.; Iwakuma, M.; Funaki, K.; Bohno, T.; Tomioka, A.; Yagi, Y.; Maruyama, H.; Ohashi, K.

    2002-08-01

    A 22 kV/6.9 kV-1 MVA high- Tc superconducting (HTS) power transformer has been developed as a prototype with single-phase part of a 3 MVA HTS power transformer. The prototype unit is cooled by a continuous subcooled liquid nitrogen (LN 2) supply system with cryocoolers. During the field tests, the HTS transformer was connected to a distribution line at Imajuku substation (Kyushu Electric Power Co., Inc.) in Fukuoka, and inrush-current test and a long-term operation test were implemented. The test results demonstrated the HTS power transformer's applicability to a power grid.

  14. High-Density-Tape Casting System

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1987-01-01

    Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

  15. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. PMID:26898963

  16. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  17. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain. PMID:26311991

  18. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  19. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-07-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain.

  20. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain.

  1. Temperature regulation in rats exposed to a 2 G field

    NASA Technical Reports Server (NTRS)

    Ishihama, Linda M.; Murakami, Dean M.; Fuller, Charles A.

    1989-01-01

    The regulation of body temperature involves both homeostatic and circadian control systems. Both systems are influenced by exposure to hyperdynamic fields and demonstrate acute responses that eventually recover to an adapted level. This experiment examined both the homeostatic and circadian responses of body temperature to a separate environmental challenge (high frequency light/dark cycles) during exposure to a 2 G hyperdynamic field.

  2. Measuring the performance of G2G services in Iran

    NASA Astrophysics Data System (ADS)

    Zarei, Behrouz; Safdari, Maryam

    To highlight the growth of e-government and the importance of its services it is essential to evaluate the performance of the service delivery to customers. Research indicates that traditional performance indexes are not suitable for this evaluation; moreover, it is noticeable that the e-government services are intangible and invisible. Among different e-government services, measurement of quality government to government (G2G) services has been less attractive for researchers while crucial for government policy-makers. This calls for a better understanding of the specific needs of users of these services in order to provide appropriate type and level of services that meets those needs. In this paper, the performance of the G2G services is measured in the Iranian context. For this purpose, SERVQUAL, which is a well-known method for assessing service quality, is employed. This study proposes and tests a five-factor of SERVQUAL instrument to explain user satisfaction and gap analysis, between expectations and perceptions of its customers, consisting thirty ministries and main governmental organizations. Based on a Chi-square test, factor analysis, gap analysis and correlations, it is concluded the gap between expectations and perceptions of G2G customers is significant and customer satisfaction of G2G services is at low level.

  3. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  4. Video Tape and the Mentally Retarded

    ERIC Educational Resources Information Center

    Weisbord, H. F.

    1972-01-01

    Three uses of video tape recordings with the mentally retarded; discussed briefly are staff training or teacher education, parental involvement in the child's education, and therapeutic uses by psychiatrists and psychologists. (CB)

  5. Carbon nanotube-based synthetic gecko tapes.

    PubMed

    Ge, Liehui; Sethi, Sunny; Ci, Lijie; Ajayan, Pulickel M; Dhinojwala, Ali

    2007-06-26

    We have developed a synthetic gecko tape by transferring micropatterned carbon nanotube arrays onto flexible polymer tape based on the hierarchical structure found on the foot of a gecko lizard. The gecko tape can support a shear stress (36 N/cm(2)) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micrometer-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak van der Waals interactions into high shear forces. We have demonstrated for the first time a macroscopic flexible patch that can be used repeatedly with peeling and adhesive properties better than the natural gecko foot. The carbon nanotube-based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics, and space applications.

  6. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  7. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  8. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  9. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability

    PubMed Central

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-01-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability. PMID:26311206

  10. Read/write head for a magnetic tape device having grooves for reducing tape floating

    DOEpatents

    Aoki, Kenji

    2005-08-09

    A read/write head for a magnetic tape includes an elongated chip assembly and a tape running surface formed in the longitudinal direction of the chip assembly. A pair of substantially spaced parallel read/write gap lines for supporting read/write elements extend longitudinally along the tape running surface of the chip assembly. Also, at least one groove is formed on the tape running surface on both sides of each of the read/write gap lines and extends substantially parallel to the read/write gap lines.

  11. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability.

    PubMed

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-07-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability.

  12. Getting a charge out of transparent tape

    NASA Astrophysics Data System (ADS)

    Harrington, Randal

    2000-01-01

    When two pieces of transparent tape are placed on top of each other (sticky side to nonsticky side) and then separated, it is observed that one piece becomes negatively charged and the other positively charged. The sign of the charge on each piece depends on the brand of tape used. This phenomenon is frequently used to investigate the properties of charge and charged objects in introductory physics courses.

  13. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  14. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  15. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  16. Towards large scale HTS Josephson detector arrays for THz imaging

    NASA Astrophysics Data System (ADS)

    Du, J.; Hellicar, A. D.; Leslie, K. E.; Nikolic, N.; Hanham, S. M.; Macfarlane, J. C.; Foley, C. P.

    2013-11-01

    We present the design and implementation of a high-temperature superconducting (HTS) Josephson junction detector array for terahertz (THz) imaging. The array device is made of ten YBa2Cu3Ox-7 (YBCO) step-edge junctions coupled to gold thin-film ring-slot antennas on a MgO substrate. The design and characterization of the detector array in response to a 0.6 THz signal are presented. The development of multi-channel biasing and read-out electronics and the system integration with a commercial cryocooler are also described.

  17. The Basic Properties of PPLP for HTS DC Cable

    NASA Astrophysics Data System (ADS)

    Kim, W. J.; Kim, H. J.; Cho, J. W.; Kim, S. H.

    In order to develop high temperature superconducting (HTS) DC cable, it is important to understand the cooling system, high voltage insulation and materials at cryogenic temperature. Especially, the basic properties of insulating materials must be solved for the long life, reliability and compact of system. In this paper, we will discuss mainly on the electrical and the mechanical properties of polypropylene laminated paper (PPLP) in liquid nitrogen (LN2). The polarity effect of DC and impulse voltage, the volume resistivity and the space charge distribution and frost were studied. Furthermore, the mechanical properties such as tensile strength of PPLP at LN2 (77 K) and room temperature (300 K) were studied.

  18. Rating underground pipeline tape and shrink sleeve coating systems

    SciTech Connect

    Norsworthy, R.

    1999-11-01

    A rating system was developed for several coating types used for underground pipeline systems. Consideration included soil stress, adhesion, surface preparation, cathodic protection (CP) shielding, CP requirements, handling and construction, repair, field joint system, bends and other components, and the application process. Polyethylene- and polyvinyl chloride-backed tapes, woven polyolefin geotextile fabric (WGF)-backed tapes, hot-applied tapes, petrolatum- and wax-based tapes, and shrink sleeves were evaluated. WGF-backed tapes had the highest rating.

  19. Design and Development of a 100 MVA HTS Generator for Commercial Entry

    SciTech Connect

    2007-06-07

    In 2002, General Electric and the US Department of Energy (DOE) entered into a cooperative agreement for the development of a commercialized 100 MVA generator using high temperature superconductors (HTS) in the field winding. The intent of the program was to: (1) identify and develop technologies that would be needed for such a generator; (2) develop conceptual designs for generators with ratings of 100 MVA and higher using HTS technology; (3) perform proof of concept tests at the 1.5 MW level for GE's proprietary warm iron rotor HTS generator concept; and (4) design, build, and test a prototype of a commercially viable 100 MVA generator that could be placed on the power grid. This report summarizes work performed during the program and is provided as one of the final program deliverables. The design for the HTS generator was based on GE's warm iron rotor concept in which a cold HTS coil is wound around a warm magnetic iron pole. This approach for rotating HTS electrical machinery provides the efficiency benefits of the HTS technology while addressing the two most important considerations for power generators in utility applications: cost and reliability. The warm iron rotor concept uses the least amount of expensive HTS wire compared to competing concepts and builds on the very high reliability of conventional iron core stators and armature windings.

  20. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  1. Application of shielding current in bulk HTS to control magnetic field distribution

    NASA Astrophysics Data System (ADS)

    Kii, T.

    2016-03-01

    Superconducting shielding current is excited when external field is applied to superconductor. In case for field cooling of bulk superconductor, shielding current is an origin of strong trapped field. When external field is changed to a properly arranged bulk HTS array, various magnetic field distribution can be formed by an excited shielding current in each bulk HTS. This paper presents a simple intuitively method to design magnetic field distribution using supercurrents in bulk high-temperature superconductor (HTS) array. In this method, an ideal current path for intended field distribution is represented by shielding currents in bulk HTS array. Expected performance can be roughly estimated by using Biot-Savart law. As examples, Maxwell coil pair and helical field generator are designed. This method can be applied to design various magnet devices using bulk HTS array.

  2. Development of REBCO HTS Magnet of Magnetic Bearing for Large Capacity Flywheel Energy Storage System

    NASA Astrophysics Data System (ADS)

    Mukoyama, Shinichi; Matsuoka, Taro; Furukawa, Makoto; Nakao, Kengo; Nagashima, Ken; Ogata, Masafumi; Yamashita, Tomohisa; Hasegawa, Hitoshi; Yoshizawa, Kazuhiro; Arai, Yuuki; Miyazaki, Kazuki; Horiuchi, Shinichi; Maeda, Tadakazu; Shimizu, Hideki

    A flywheel energy storage system (FESS) is a promising electrical storage system that moderates fluctuation of electrical power from renewable energy sources. The FESS can charge and discharge the surplus electrical power repetitively with the rotating energy. Particularly, the FESS that utilizes a high temperature superconducting magnetic bearing (HTS bearing) is lower loss than conventional FESS that has mechanical bearing, and has property of longer life operation than secondary batteries. The HTS bearing consists of a HTS bulk and double-pancake coils used 2nd generation REBCO wires. In the development, the HTS double-pancake coils were fabricated and were provided for a levitation test to verify the possibility of the HTS bearing. We successfully confirmed the magnetic field was achieved to design value, and levitation force in the configuration of one YBCO bulk and five double pan-cake coils was obtained to a satisfactory force of 39.2 kN (4 tons).

  3. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  4. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    PubMed Central

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  5. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    PubMed

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  6. 5 MJ flywheel based on bulk HTS magnetic suspension

    NASA Astrophysics Data System (ADS)

    Poltavets, V.; Kovalev, K.; Ilyasov, R.; Glazunov, A.; Maevsky, V.; Verzbitsky, L.; Akhmadyshev, V.; Shikov, A.

    2014-05-01

    Nowadays the flywheel energy storage systems (FES) are developed intensively as uninterruptible power supply (UPS) devices for on-land and transport (especially airborne) applications worldwide. This work is devoted to the FES with magnetic suspension on the base of bulk HTS YBCO elements and permanent magnets. The developed FES is intended to be used as UPS in Russian atomic industry in case of an emergency. For the successful design of the FES the following questions should be solved: design of the motor/generator, design of the rotor (flywheel), design of the bearing system, design of the control system and system of power load matching, design of the cooling system. The developed small-scale FES with the stored energy 0.5 MJ was used to solve these basic questions. The elaborated FES consists of the synchronous electric machine with permanent magnets, the solid flywheel with axial magnetic suspension on the base of YBCO bulks and permanent magnets, the system of control and power load matching, and the system of liquid nitrogen cooling. The results of theoretical modeling of different schematics of magnetic suspension and experimental investigations of the constructed FES are presented. The design of the future full-scale FES with the stored energy ~5 MJ and output power up to 100 kW is described. The test results of the flywheel rotor and HTS magnetic suspension of 5 MJ FES are presented. This work is done under support of Rosatom within the frames of Russian Project "Superconducting Industry"

  7. HTS cables open the window for large-scale renewables

    NASA Astrophysics Data System (ADS)

    Geschiere, A.; Willén, D.; Piga, E.; Barendregt, P.

    2008-02-01

    In a realistic approach to future energy consumption, the effects of sustainable power sources and the effects of growing welfare with increased use of electricity need to be considered. These factors lead to an increased transfer of electric energy over the networks. A dominant part of the energy need will come from expanded large-scale renewable sources. To use them efficiently over Europe, large energy transits between different countries are required. Bottlenecks in the existing infrastructure will be avoided by strengthening the network. For environmental reasons more infrastructure will be built underground. Nuon is studying the HTS technology as a component to solve these challenges. This technology offers a tremendously large power transport capacity as well as the possibility to reduce short circuit currents, making integration of renewables easier. Furthermore, power transport will be possible at lower voltage levels, giving the opportunity to upgrade the existing network while re-using it. This will result in large cost savings while reaching the future energy challenges. In a 6 km backbone structure in Amsterdam Nuon wants to install a 50 kV HTS Triax cable for a significant increase of the transport capacity, while developing its capabilities. Nevertheless several barriers have to be overcome.

  8. HTS Magnets for Advanced Magnetoplasma Space Propulsion Applications

    SciTech Connect

    Carte, M.D.; Chang-Diaz, F.R. Squire, J.P.; Schwenterly, S.W.

    1999-07-12

    Plasma rockets are being considered for both Earth-orbit and interplanetary missions because their extremely high exhaust velocity and ability to modulate thrust allow very efficient use of propellant mass. In such rockets, a hydrogen or helium plasma is RF-heated and confined by axial magnetic fields produced by coils around the plasma chamber. HTS coils cooled by the propellant are desirable to increase the energy efficiency of the system. We describe a set of prototype high-temperature superconducting (HTS) coils that are being considered for the VASIMR ( Variable Specific Impulse Magnetoplasma Rocket) thruster proposed for testing on the Radiation Technology Demonstration (RTD) satellite. Since this satellite will be launched by the Space Shuttle, for safety reasons liquid helium will be used as propellant and coolant. The coils must be designed to operate in the space environment at field levels of 1 T. This generates a unique set of requirements. Details of the overall winding geometry and current density, as well as the challenging thermal control aspects associated with a compact, minimum weight design will be discussed.

  9. Sub-Micron Long HTS Ho Electron Mixers

    NASA Technical Reports Server (NTRS)

    Harnack, 0.; Karasik, B. S.; McGrath, W. R.; Kleinsasser, A. W.; Barner, J. B.

    2000-01-01

    The hot-electron bolometer mixer made from a high-T, superconductor (HTS) was introduced recently as an alternative to a Schottky mixer at THz frequencies. The performance of the mixer depends on the total thermal conductance for heat removal from the phonon sub-system due to either length-dependent phonon diffusion or phonon escape to the substrate. We have measured both the length and temperature dependencies of the IF bandwidth of the mixers fabricated from 25-35 mn thick YBCO films on MgO and sapphire substrates. The films were grown by a laser deposition technique and electron-beam lithography was used to define bridge lengths down to 50 nm. Mixer measurements were done using signal frequencies in the range of 1-100 GHz. For 50 nm and 400 nm long devices on MgO, the 3-dB bandwidth was about 100 MHz. At temperatures below 60 K, the hot-electron plateau was clearly seen starting around 2-3 GHz. At temperatures above 70 K, the flux-flow effects begin to dominate and the IF bandwidth increases to 1-8 GHz, while the conversion efficiency drops by several dB. This temperature dependence of the IF bandwidth can account for previously reported unexpectedly high bandwidth of HTS mixers.

  10. Restoration and testing of an HTS fault current controller

    SciTech Connect

    Waynert, J. A.; Boenig, H.; Mielke, C. H.; Willis, J. O.; Burley, B. L.

    2002-01-01

    A three-phase, 1200 A, 12.5 kV fault current controller using three HTS 4 mH coils, was built by industry and tested in 1999 at the Center Substation of Southern California Edison in Norwalk, CA. During the testing, it appeared that each of the three single-phase units had experienced a voltage breakdown, one externally and two internally. Los Alamos National Laboratory (LANL) was asked by DOE to restore the operation of the fault current controller provided the HTS coils had not been damaged during the initial substation tests. When the internally-failed coil vacuum vessels were opened it became evident that in these two vessels, a flashover had occurred at the high voltage bus section leading to the terminals of the superconducting coil. An investigation into the failure mechanism resulted in six possible causes for the flashover. Based on these causes, the high voltage bus was completely redesigned. Single-phase tests were successfully performed on the modified unit at a 13.7 kV LANL substation. This paper presents the postulated voltage flashover failure mechanisms, the new high voltage bus design which mitigates the failure mechanisms, the sequence of tests used to validate the new design, and finally, the results of variable load and short-circuit tests with the single-phase unit operating on the LANL 13.7 kV substation.

  11. HTS compatible assay for antioxidative agents using primary cultured hepatocytes.

    PubMed

    Gaunitz, Frank; Heise, Kerstin

    2003-06-01

    We have used primary cultured rat hepatocytes to establish a system that is compatible with HTS for screening substance libraries for biologically active compounds. The hepatocytes were treated with t-BHP to induce oxidative stress, leading to the formation ROS. The involvement of ROS in oxidative stress and pathological alterations has been of major interest in recent years, and there is great demand to identify new compounds with antioxidant potential. In most HTS programs each compound is tested in duplicate, and may only be tested once. Because of this it is important to develop assays that can identify candidate compounds accurately and with high confidence. Using newly available cell-based assay systems, we have developed a system that can detect active compounds (hits) with a high degree of confidence. As an example of an agent that can be detected from a substance library, we analyzed the effect of fisetin as an antioxidative compound using this system. All measurements were performed using the newly developed and highly versatile Multilabel-Reader Mithras LB 940 (Berthold Technologies, Bad Wildbad, Germany). The data presented show that all Z' factors determined were highly reliable. Although the protocol is primarily designed to screen for substances with antioxidative potential, it can easily be adapted to screen for other biologically active substances.

  12. Ubiquitous Graphene Electronics on Scotch Tape.

    PubMed

    Chung, Yoonyoung; Kim, Hyun Ho; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm(-2), so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm(2) V(-1) s(-1); the transistors still showed high mobility of 1254 (±478) cm(2) V(-1) s(-1) even after they were crumpled. PMID:26220874

  13. Ubiquitous Graphene Electronics on Scotch Tape

    NASA Astrophysics Data System (ADS)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  14. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  15. Processing and transport properties of high J[sub c] silver clad Bi-2223 tapes and coils

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr. ); Balachandran, U. . Materials and Components Technology Div.); Motowidlo, L.R. )

    1993-02-01

    The powder-in-tube process has been used to fabricate long lengths of flexible, high J[sub c], silver clad Bi-2223 HTS conductors. By improving thermo-mechanical processing and precursor powder preparationwe have succeeded in achieving J[sub c]'s exceeding 4 [times] 10[sup 4] A/cm[sup 2] at liquid nitrogen (77K) and > 10[sup 5] A/cm[sup 2] at liquid helium (4.2K) and liquid neon (27K) temperatures for short tapesamples. Detailed measurements with high applied magnetic fields are reported. Several long tapes up to 10 meters in length have also been fabricated and co-wound into small superconducting pancake coils using the wind-and-react'' approach. Transport measurements at 77K and 4.2K for these coils are also reported.

  16. Processing and transport properties of high J{sub c} silver clad Bi-2223 tapes and coils

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Balachandran, U.; Motowidlo, L.R.

    1993-02-01

    The powder-in-tube process has been used to fabricate long lengths of flexible, high J{sub c}, silver clad Bi-2223 HTS conductors. By improving thermo-mechanical processing and precursor powder preparationwe have succeeded in achieving J{sub c}`s exceeding 4 {times} 10{sup 4} A/cm{sup 2} at liquid nitrogen (77K) and > 10{sup 5} A/cm{sup 2} at liquid helium (4.2K) and liquid neon (27K) temperatures for short tapesamples. Detailed measurements with high applied magnetic fields are reported. Several long tapes up to 10 meters in length have also been fabricated and co-wound into small superconducting pancake coils using the ``wind-and-react`` approach. Transport measurements at 77K and 4.2K for these coils are also reported.

  17. Using magnetic tape technology for data migration

    NASA Technical Reports Server (NTRS)

    Therrien, David; Cheung, Yim-Ling

    1993-01-01

    Magnetic tape and optical disk library units (jukeboxes) are satisfying the demand for high-capacity cost-effective storage. The choice between optical disk and magnetic tape technology must take into account the cost limitations as well as the performance and reliability requirements of the user environment. Library units require data management software in order to function in an automated and user-transparent way. The most common data management applications are backup and recovery, data migration, and archiving. The medium access patterns that these applications create will be described. Since the most user visible application is data migration, a queue simulator was developed to model its performance against a variety of library units. The major subject of this paper is the design and implementation of this simulator as well as some simulation results. The relative cost and reliability of magnetic tape versus optical disk library units is presented for completeness.

  18. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  19. Catalog of the Oak Ridge National Laboratory Meteorological Tape Library

    SciTech Connect

    Bell, M.A.

    1983-08-01

    This report gives a complete inventory of the data tapes in the ORNL Meteorological Tape Library (OMTL). The attributes of each tape, including location of the weather station (city and state), station number, standard data format, dates covered, data set name(s), and job control language considerations (record format, record length, blocksize, tape label, and tape density), are listed for each tape. In addition, a description of some of the special characteristics of each of the available standard meteorological data formats is presented.

  20. Engineered pinning landscapes for enhanced 2G coil wire

    DOE PAGES

    Rupich, Martin W.; Sathyamurthy, Srivatsan; Fleshler, Steven; Li, Qiang; Solovyov, Vyacheslav; Ozaki, Toshinori; Welp, Ulrich; Kwok, Wai -Kwong; Leroux, Maxime; Koshelev, Alexei E.; et al

    2016-04-01

    We demonstrate a twofold increase in the in-field critical current of AMSC's standard 2G coil wire by irradiation with 18-MeV Au ions. The optimum pinning enhancement is achieved with a dose of 6 × 1011 Au ions/cm2. Although the 77 K, self-field critical current is reduced by about 35%, the in-field critical current (H//c) shows a significant enhancement between 4 and 50 K in fields > 1 T. The process was used for the roll-to-roll irradiation of AMSC's standard 46-mm-wide production coated conductor strips, which were further processed into standard copper laminated coil wire. The long-length wires show the samemore » enhancement as attained with short static irradiated samples. The roll-to-roll irradiation process can be incorporated in the standard 2G wire manufacturing, with no modifications to the current process. In conclusion, the enhanced performance of the wire will benefit rotating machine and magnet applications.« less

  1. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  2. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-01-01

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  3. Effects of Kinesio taping and Mcconnell taping on balance and walking speed of hemiplegia patients

    PubMed Central

    Choi, Yong-Kyu; Park, Young-Han; Lee, Jung-Ho

    2016-01-01

    [Purpose] The aim of this study was to evaluate the overlap effect of the PNF following the application of Kinesio taping and the McConnell taping, and also the impact of the taping application method on the balance and walking speed of the patients with stroke. [Subjects and Methods] Thirty-six patients who were diagnosed with hemiplegia due to stroke were selected as subjects of this study. They were randomly and evenly divided into experiment group 1 (Kinesio taping group), experiment group 2 (McConnell taping group), and the control group; each group had 12 patients. [Results] The Berg balance scale (BBS) was used to evaluate balance, and the ability in this study. A 10 m walking test (10MWT) was performed to measure the walking speed. Experiment group 1 showed a statistically significant improvement in balance and walking speed compared to experiment group 2, and the control group in week 4 and week 8. [Conclusion] Application of Kinesio taping had a more beneficial effect on the balance and walking speed than joint-fixation taping of the patients with stroke. PMID:27190448

  4. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  5. Experimental Studies on Cryogenic System for 22.9 KV Hts Cable Sytem

    NASA Astrophysics Data System (ADS)

    Sohn, S. H.; Lim, J. H.; Yang, H. S.; Kim, D. L.; Ryoo, H. S.; Kim, C. D.; Kim, D. H.; Lee, S. K.; Hwang, S. D.

    2008-03-01

    In terms of high transmission capacity with lower voltage, a high temperature superconducting (HTS) cable system is a very attractive challenge for utilities. However, the concomitant cryogenic system for the HTS cable system is one of the tantalizing problems in the operation. The reliability and maintainability of cryogenic system are the key issues to apply it to the real electric power grid. Korea Electric Power Corporation (KEPCO) is making an attempt to verify the applicability of the HTS cable system to improve the efficiency of electric power industry. Since May 2006, a 22.9-kV, 50-MVA, 3-phase, 100-m class HTS cable system with an open cooling system has been operated at the KEPCO Gochang test yard. Concurrently, another HTS cable verification test with the same electrical specification and an hybrid cooling system has been carried out by LS Cable (LSC) Ltd in close proximity to the KEPCO's HTS cable system within Gochang test yard. KEPCO conducts the operation of the open cooling system, and is evaluating the hybrid system of LSC with respect to facility performance and usability. This paper compares the cryogenic performance of both HTS cable systems and discusses cooling test results such as step response.

  6. Influence analysis of structural parameters and operating parameters on electromagnetic properties of HTS linear induction motor

    NASA Astrophysics Data System (ADS)

    Fang, J.; Sheng, L.; Li, D.; Zhao, J.; Li, Sh.; Qin, W.; Fan, Y.; Zheng, Q. L.; Zhang, W.

    A novel High Temperature Superconductor Linear Induction Motor (HTS LIM) is researched in this paper. Since the critical current and the electromagnetic force of the motor are determined mainly by the primary slot leakage flux, the main magnetic flux and eddy current respectively, in order to research the influence of structural parameters and operating parameters on electromagnetic properties of HTS LIM, the motor was analyzed by 2D transient Finite Element Method (FEM). The properties of the motor, such as the maximum slot leakage flux density, motor thrust, motor vertical force and critical current are analyzed with different structural parameters and operating parameters. In addition, an experimental investigation was carried out on prototype HTS motor. Electrical parameters were deduced from these tests and also compared with the analysis results from FEM. AC losses of one HTS coil in the motor were measured and AC losses of all HTS coils in HTS LIM were estimated. The results in this paper could provide reference for the design and research on the HTS LIM.

  7. Analysis on heat loss characteristics of a 10 kV HTS power substation

    NASA Astrophysics Data System (ADS)

    Teng, Yuping; Dai, Shaotao; Song, Naihao; Zhang, Jingye; Gao, Zhiyuan; Zhu, Zhiqin; Zhou, Weiwei; Wei, Zhourong; Lin, Liangzhen; Xiao, Liye

    2014-09-01

    A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

  8. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  9. Elastic therapeutic tape: do they have the same material properties?

    PubMed Central

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-01-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex®, ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight® 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young’s modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young’s modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape. PMID:27190472

  10. Elastic therapeutic tape: do they have the same material properties?

    PubMed

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-04-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex(®), ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight(®) 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young's modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young's modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape.

  11. High solids loading for water-based tape casting

    NASA Astrophysics Data System (ADS)

    Suwannasiri, Thitima

    Tape Casting is a low cost process for making large-area, thin, flat ceramics, which traditionally utilizes organic solvents to allow fast drying.sp{1-4} However, some of the volatile organic compounds (VOC), such as toluene, methylethyl ketone (MEK), and cyclohexanone, are hazardous air pollutants, and their emissions need to be regulated. Therefore, using water as a solvent is desirable to avoid the need of trapping VOCs. Although water is of low cost, nonflammable and safe to the environment, its heat of vaporization is high, 540 kca/g, compared to that of toluene, 74 kca/g.sp7 This makes the drying slow when water is used. The use of water in a tape casting formulation has previously been practical just for applications which require very thin tape, 100-200 mum. A high solids loading of above 50 vol% is an alternative approach to obtain sufficiently rapid drying for a thicker tape (up to 0.8 mm) since the water content is originally minimized. In order to obtain a high solids loading, the dispersants and binder systems were carefully tailored during the present research project. Low molecular weight polyelectrolytes, such as polyacrylic acid PAA (M.W. 1800) and citric acid, were found to be effective for high solids loading of Alsb2Osb3 (A-16SG), for which the electrosteric stabilization played an important role to the stability of the suspension. The viscosity and flow behavior of the suspension strongly depended on pH and the amount of polyelectrolyte, which could be related to the configuration of the polyelectrolyte molecules on the powder surface. The high solids loading of 64.5 vol% could be obtained for the fine A-16SG powder which had a surface area of 9.3 msp2/g. For the coarser powder, A-152SG, the dilatancy was a major problem that obstructed a further rise in solids loading. The dilatancy could be minimized by modifying the size distribution with A-152SG plus A-16SG and using a proper pH and amount of dispersants. An extremely high solids loading of

  12. HTS Josephson heterodyne oscillator on a pulse-tube cryocooler

    NASA Astrophysics Data System (ADS)

    Du, J.; Macfarlane, J. C.; Lam, S. H. K.; Taylor, R.

    2009-10-01

    A high-temperature superconducting (HTS) Josephson heterodyne oscillator based on step-edge junction technology has recently been developed (Du et al 2008 Appl. Phys. Lett. 93 033507, Macfarlane et al 2009 IEEE Trans. Appl. Supercond. 19 920). In this work, the implementation and characterization of such a heterodyne oscillator on a compact pulse-tube cryocooler (PTC) are presented. The rf performance of the oscillator cooled by the cryocooler is compared to that of the same device when cooled in the quiet gas phase of a liquid helium Dewar. Any measurable influence of additional electromagnetic noise and mechanical vibration of the cryocooler on the oscillator performance is assessed by measuring the linewidth broadening of the heterodyne oscillation. The cryocooled oscillator demonstrated excellent performance and negligible excess noise was observed when operating the PTC.

  13. Magnetizing of permanent magnets using HTS bulk magnets

    NASA Astrophysics Data System (ADS)

    Oka, Tetsuo; Muraya, Tomoki; Kawasaki, Nobutaka; Fukui, Satoshi; Ogawa, Jun; Sato, Takao; Terasawa, Toshihisa

    2012-01-01

    A demagnetized Nd-Fe-B permanent magnet was scanned just above the magnetic pole which contains the HTS bulk magnet generating a magnetic field of 3.27 T. The magnet sample was subsequently found to be fully magnetized in the open space of the static magnetic fields. We examined the magnetic field distributions when the magnetic poles were scanned twice to activate the magnet plate inversely with various overlap distances between the tracks of the bulk magnet. The magnetic field of the "rewritten" magnet reached the values of the magnetically saturated region of the material, showing steep gradients at the border of each magnetic pole. As a replacement for conventional pulse field magnetizing methods, this technique is proposed to expand the degree of freedom in the design of electromagnetic devices, and is proposed as a novel practical method for magnetizing rare-earth magnets, which have excellent magnetic performance and require intense fields of more than 3 T to be activated.

  14. Thermal property of insulation material for HTS power cable

    NASA Astrophysics Data System (ADS)

    Choi, Yeon Suk; Kim, D. L.; Shin, D. W.; Hwang, S. D.

    2012-06-01

    The thermal property of insulation material is essential in developing a high temperature superconductor (HTS) power cable operating at around liquid nitrogen temperature. The accurate estimate of the heat flux is difficult in the nonmetallic materials because nonmetallic materials have a high thermal resistance and low temperature gradient along the specimen. The objective of the present work is to develop a precise instrument for measuring the thermal conductivity of insulating materials over a temperature range of 30 K to approximately the room temperature by using a cryocooler. The thermal conductivity of Teflon is measured and the accuracy confirmation is carried out by comparing published data. In addition, the experimental results of apparent thermal conductivity of polypropylene laminated paper (PPLP) are presented and the temperature dependency is also discussed

  15. Bi-2223 HTS winding in toroidal configuration for SMES coil

    NASA Astrophysics Data System (ADS)

    Kondratowicz-Kucewicz, B.; Janowski, T.; Kozak, S.; Kozak, J.; Wojtasiewicz, G.; Majka, M.

    2010-06-01

    Energy can be stored in the magnetic field of a coil. Superconducting Magnetic Energy Storage (SMES) is very promising as a power storage system for load levelling or power stabilizer. However, the strong electromagnetic force caused by high magnetic field and large coil current is a problem in SMES systems. A toroidal configuration would have a much less extensive external magnetic field and electromagnetic forces in winding. The paper describes the design of HTS winding for SMES coil in modular toroid configuration consist of seven Bi-2223 double-pancakes as well as numerical analysis of SMES magnet model using FLUX 3D package. As the results of analysis the paper presents the optimal coil configuration and the parameters such as radius of toroidal magnet, energy stored in magnet and magnetic field distribution.

  16. Simulation and Test for the Thermal Behaviour of a Prototype Synchronous Generator with HTS Armature Windings

    NASA Astrophysics Data System (ADS)

    Yu, X.-Y.; Qu, T.-M.; Song, P.; Li, L.-N.; Chen, D.-X.; Han, Z.

    A synchronous generator prototype with HTS armature windings and a permanent magnet rotor (HTS-PM) was developed. The temperature evolution during cooling and operation processes of the HTS coils was analyzed by finite element method (FEM). The simulated results coincided well with the temperature measurement data acquired by PT-100 sensors. Cooling time, terminal temperature, contact thermal conductivity, during cooling, as well as the proportion between real and calculated iron loss, contact thermal conductivity, at various rotating speeds during operation, were worked out using the FEM model.

  17. Design, Construction and Test of Cryogen-Free HTS Coil Structure

    SciTech Connect

    Hocker, H.; Anerella, M.; Gupta, R.; Plate, S.; Sampson, W.; Schmalzle, J.; Shiroyanagi, Y.

    2011-03-28

    This paper will describe design, construction and test results of a cryo-mechanical structure to study coils made with the second generation High Temperature Superconductor (HTS) for the Facility for Rare Isotope Beams (FRIB). A magnet comprised of HTS coils mounted in a vacuum vessel and conduction-cooled with Gifford-McMahon cycle cryocoolers is used to develop and refine design and construction techniques. The study of these techniques and their effect on operations provides a better understanding of the use of cryogen free magnets in future accelerator projects. A cryogen-free, superconducting HTS magnet possesses certain operational advantages over cryogenically cooled, low temperature superconducting magnets.

  18. Development of Coated Conductors in Japanese National Project "Development of Fundamental Technologies for HTS Coils"

    NASA Astrophysics Data System (ADS)

    Yoshizumi, Masateru; Izumi, Teruo; Shiohara, Yuh

    RE1Ba2Cu3O7-x (REBCO, RE=rare earth) coated conductors have attracted the attention of many scientists due to the high superconducting properties, etc. Due to the great progress of R&D on coated conductors, the activities have shifted to specific applications. The new Japanese national project, named as "Development of Fundamental Technologies for HTS Coils", started last year aiming for the applications of MRI and medical accelerators. To meet the requirements of those applications, the R&D of REBCO coated conductors (CCs) are being performed with that of coiling technology in parallel. The theme has two sub-themes of "development of long CCs with high in-field performance" and "development of CCs with extremely low heat generation" in this national project. The ambitious goals of these themes are set as intermediate ones due 2016 Mar; the theme of in-field: 100m-500A/cm-w@65K, 3T -850A/cm-w@35K, 10T, the theme of low heat generation: 100m-500 μm of filament width w/ Icfilament inhomogeneity of distribution within 10% and joint resistance below 5nΩ. The final goals of these themes due 2018 Mar. were set as follows; the theme of in-field: 200m-600A/cm-w@65K, 3T -1000A/cm-w@35K, 10T, the theme of low heat generation: 200m-500 μm of filament width w/ Icfilament distribution within 5% and joint resistance below 3nΩ. The objectives, goals and progress of this project will be reviewed in this article. As for the progress, for example, the combination of EuBCO+BHO was found to be effective to improve the in-field performance of PLD derived coated conductors. A 94 m long wire with Icmin of 108A/cm-w@77K, 3T (corresponding to 472A/cm-w @65K, 3T) was successfully fabricated. It is as twice Icmin of the long tape as the highest one in the previous project.

  19. FGGE/SMMR-30 tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/SMMR-30 tape which contains sea ice concentration data in 30 km resolution which are extracted and reformatted from Nimbus-7 SMMR PARM-30 tapes in accordance with the FGGE level II International Exchange Format Specification is outlined. There are three types of files on a FGGE/SMMR-30 tape. The first file on the tape is a test file. The second file on the tape is a tape header file. The remaining one or more files are data files. All files are terminated with a single end of file (EOP) tape mark. The last file is terminated with two EOF tape marks. All files are made up of one or more physical records. Each physical record contains 2960 bytes. Each data file contains all available values for a 6 hour synoptic time period.

  20. Tape It Yourself: Videotapes for Teacher Education

    ERIC Educational Resources Information Center

    Ebsworth, Miriam Eistein; Feknous, Barbara; Loyet, Dianne; Zimmerman, Spencer

    2004-01-01

    This paper describes the development and implementation of a series of videotapes of ESL classes for a pre-service teacher education program grounded in experiential learning theory. The videos included footage of ESL classrooms, and tapes edited and supplemented with interviews of ESL teachers. Our experience demonstrates that-with relatively low…

  1. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game, "Twister." She finds…

  2. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  3. Carbon Nanotube-Based Synthetic Gecko Tapes

    NASA Astrophysics Data System (ADS)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  4. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  5. Tape Lessons to Accompany Intermediate Nepali Reader.

    ERIC Educational Resources Information Center

    Verma, Manindra K.

    These tape lessons follow the sequence of the intermediate Nepali Reader. There are 12 lessons each containing various types of exercises designed to increase listening, speaking, and reading skills. Each lesson contains the following types of exercises: (1) listening comprehension; (2) question answering; (3) repetition; and (4) multiple choice…

  6. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  7. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  8. Multiprocessor system for Holter tape analysis (ECG)

    SciTech Connect

    Feldman, C.L.; Hubelbank, M.; Valvo, V.; Lane, B.

    1983-01-01

    Although techniques for recording and analyzing longterm ambulatory ECGS have been in existence for more than 20 years, the clinical usefulness and frequency of application of the technique continue to grow at an extraordinary rate. To meet the need for faster, more efficient processing of Holter tapes and the growing requirement that the analysis of the tape be quantitatively accurate, a new Holter analysis system has been developed. This system is built around two LSI11 microprocessors and a special purpose byte processor which incorporates an AMD 2903 bit slice chip. It includes 30 MB of mass storage and an impact printer with alphanumeric and graphic capabilities. In a test which included 55 separate readings of 34 12- or 24-hour tapes, correlations with hand counts of vpbs was greater than .99. The system processes either cassette or reel-to-reel tapes at 120* with simultaneous print/process capabilities, has a variety of user interactive displays to assure continuous operator validation, is remarkably nonfatiguing to operate, and automatically produces reports with tables, graphs, and sample ECG strips. 8 references.

  9. A Tape-Lecture Course in Electrochemistry.

    ERIC Educational Resources Information Center

    Sheridan, P.

    1978-01-01

    Investigates the possibility of using audio-tapes for self-study courses in technical colleges. This article presents: (1) description of the electrochemistry course taught; (2) results of the assessment of student reaction to the course; and (3) conclusions. (HM)

  10. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  11. Inconsistencies in tape read and tape write programs on the I-100 image analysis system

    NASA Technical Reports Server (NTRS)

    Hocutt, W. T. (Principal Investigator)

    1978-01-01

    The author has identified the following significant results. The tape read and write programs currently available on the 1-100 perform their intended functions of reading and writing tapes, but are difficult to use because they contain a number of inconsistencies. These inconsistencies can often be overcome by the use of work-around procedures and by trial and error, which is an inefficient use of expensive computer systems that should not be necessary.

  12. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  13. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  14. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical magnetic tape recorder. 870.2800 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800 Medical magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  15. Full tape thickness feature conductors for EMI structures

    DOEpatents

    Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.; Barner, Gregory

    2014-06-10

    Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.

  16. STS-102 Mission Highlight Resource Tape, Tape 1 of 4. Part A

    NASA Technical Reports Server (NTRS)

    2001-01-01

    This video gives an overview of the first four flight days of the STS-102 mission through a compilation of footage from each day. The crew of STS-102 (Commander James Wetherbee, Pilot James Kelly, and Mission Specialists Andrew Thomas and Paul Richards) and the Expedition 2 crew (Commander Yuriy Usachev and Flight Engineers James Voss and Susan Helms) are seen during the ceremonial breakfast, suitup, and as they board Discovery. The orbiter's launch is seen from several different viewpoints, and various in-flight activities are shown, such as the opening of Discovery's payload bay doors, Helms preparing for the 'H-Reflex Experiment: Effects of Microgravity on the Spine', the rendezvous and docking of Discovery with the International Space Station (ISS), and Helms and Voss preparing for and performing their spacewalks. The crew of STS-102 and both Expedition crews (E1 crew William Shepherd, Yuri Gidzenko, and Sergei Krikalev) are seen in the Destiny Laboratory Module. Activities for flight day five can be seen on 'STS-102 Mission Highlight Resource Tape, Part 1 of 2, Tape 2 of 2' (internal ID 2001096941). Flight days 6-14 activities can be seen on 'STS-102 Mission Highlight Resource Tape, Part 2 of 2, Tape 1 of 2' (internal ID 2001096943) and 'STS-102 Mission Highlight Resource Tape, Part 2 of 2, Tape 2 of 2' (internal ID 2001096940).

  17. Paint and tape: collection and storage of microtraces of paint in adhesive tape.

    PubMed

    Bernhard, W R

    2000-11-01

    The collection and preservation of microtrace evidence with the aid of an adhesive tape is a method of choice in forensic science. This technique is rapid and easy and allows the concentration of microtraces on a carrier, which facilitates further investigations in the laboratory. Adhesive tapes are currently used to secure microtraces of fibers and glass, but hardly for traces of automotive paint and other lacquers for fear of interference with the analysis of binders. A collection of automotive paint consisting of original and repair lacquers collected by tape has been evaluated. After various times of storage within the tape, these samples were compared with untreated references by microscope FT-IR and microspectrophotometry (MSP). Another set of paints was collected in 1984, stored within the tape until 1995, and examined the same way. About 170 layers of lacquer with various types of binder were examined. With the exception of one clear lacquer no difference between treated samples and references was detected. This small difference observed could be correlated to the exposure to xylene (extractant) and was not caused by the storage within the adhesive tape. PMID:11110189

  18. Loss measurement and analysis for the prototype generator with HTS stator and permanent magnet rotor

    NASA Astrophysics Data System (ADS)

    Song, Peng; Qu, Timing; Yu, Xiaoyu; Li, Longnian; Gu, Chen; Li, Xiaohang; Wang, Dewen; Hu, Boping; Chen, Duxing; Han, Zhenghe

    2013-11-01

    A prototype HTS synchronous generator with a permanent magnet rotor and HTS armature windings was developed. The rated armature frequency is 10 Hz. The cryogenic Dewar is tightly surrounded outside the iron core. Both HTS coils and the iron core were cooled by using conduction cooling method. During the process of no-load running, the no-load loss power data were obtained through the torque measurement. The temperature evolution characteristics of the stator was measured by PT-100 temperature sensors. These results show that the no-load loss power at around 77 K are much larger than that at room temperature. The possible reason for the no-load loss increment is discussed. The ac loss power of one individual HTS coil used in this generator was also tested. Compared with the iron loss power, the ac loss power is rather small and could be neglected.

  19. Design, development and calibration of HTS wire based LOX level sensor probe

    NASA Astrophysics Data System (ADS)

    Karunanithi, R.; Jacob, S.; Nadig, D. S.; Prasad, M. V. N.; Gour, A. S.; Gowthaman, M.; Deekshith, P.; Shrivastava, V.

    2014-01-01

    For space applications, the weight of the liquid level sensors are of major concern as they affect the payload fraction and hence the cost. An attempt is made to design and test a light weight High Temperature Superconductor (HTS) wire based liquid level sensor for Liquid Oxygen (LOX) tank used in the cryostage of the spacecraft. The total resistance value measured of the HTS wire is inversely proportional to the liquid level. A HTS wire (SF12100) of 12mm width and 2.76m length without copper stabilizer has been used in the level sensor. The developed HTS wire based LOX level sensor is calibrated against a discrete diode array type level sensor. Liquid Nitrogen (LN2) and LOX has been used as cryogenic fluid for the calibration purpose. The automatic data logging for the system has been done using LabVIEW11. The net weight of the developed sensor is less than 1 kg.

  20. Muscle phenotypic variability in limb girdle muscular dystrophy 2 G.

    PubMed

    Paim, Julia F; Cotta, Ana; Vargas, Antonio P; Navarro, Monica M; Valicek, Jaquelin; Carvalho, Elmano; da-Cunha, Antonio L; Plentz, Estevão; Braz, Shelida V; Takata, Reinaldo I; Almeida, Camila F; Vainzof, Mariz

    2013-06-01

    Limb girdle muscular dystrophy type 2 G (LGMD2G) is caused by mutations in the telethonin gene. Only few families were described presenting this disease, and they are mainly Brazilians. Here, we identified one additional case carrying the same common c.157C > T mutation in the telethonin gene but with an atypical histopathological muscle pattern. In a female patient with a long duration of symptoms (46 years), muscle biopsy showed, in addition to telethonin deficiency, the presence of nemaline rods, type 1 fiber predominance, nuclear internalization, lobulated fibers, and mitochondrial paracrystalline inclusions. Her first clinical signs were identified at 8 years old, which include tiptoe walking, left lower limb deformity, and frequent falls. Ambulation loss occurred at 41 years old, and now, at 54 years old, she presented pelvic girdle atrophy, winging scapula, foot deformity with incapacity to perform ankle dorsiflexion, and absent tendon reflexes. The presence of nemaline bodies could be a secondary phenomenon, possibly associated with focal Z-line abnormalities of a long-standing disease. However, these new histopathological findings, characteristic of congenital myopathies, expand muscle phenotypic variability of telethoninopathy. PMID:23479141

  1. Mechanism of thickness dependence of critical current density in HTS YBCO film and its elimination using nano-engineering

    NASA Astrophysics Data System (ADS)

    Wang, Xiang

    The most promising characteristic of a High Temperature Superconductor (HTS) is its ability to carry larger electrical current at liquid nitrogen boiling temperature and strong applied magnetic field with minimal dissipation. Numerous large scale applications such as HTS transmission cables, HTS magnets and HTS motors have been developed using HTS materials. The major limitation that prevents its wide commercialization is its high cost-to-performance ratio. However, the effort to further improve HTS current carrying capability is jeopardized by a mysterious thickness dependence of the critical current density (Jc) --- Jc monotonically decreases with increasing thickness (t) at 77 K and self-field (SF). This poses a great challenge for both HTS applications and the understanding of vortex dynamics. What further complicates this issue is the complex defect structure in HTS films as well as the creep nature of magnetic vortices at a finite temperature. After a systematic study of the temperature and magnetic field effects on Jc--t, we conclude that Jc--t is most likely the result of a collective pinning effect dictated by a random pinning potential. Besides that, thermal fluctuations also alter Jc--t in a predictable way. Therefore, by either modifying the vortex structure or pinning structure, J c--t can be eliminated. Indeed, a thin film J c has been restored in a HTS/insulator/HTS trilayer while the magnetic coupling is weakened. Moreover, Jc--t has been removed when the random distributed point pins are overpowered by strong linear defects.

  2. Cryogenic Cooling System for 5 kA, 200 μH Class HTS DC Reactor

    NASA Astrophysics Data System (ADS)

    Park, Heecheol; Kim, Seokho; Kim, Kwangmin; Park, Minwon; Park, Taejun; Kim, A.-rong; Lee, Sangjin

    DC reactors, made by aluminum busbar, are used to stabilize the arc of an electric furnace. In the conventional arc furnace, the transport current is several tens of kilo-amperes and enormous resistive loss is generated. To reduce the resistive loss at the DC reactor, a HTS DC reactor can be considered. It can dramatically improve the electric efficiency as well as reduce the installation space. Similar with other superconducting devices, the HTS DC reactor requires current leads from a power source in room temperature to the HTS coil in cryogenic environment. The heat loss at the metal current leads can be minimized through optimization process considering the geometry and the transport current. However, the transport current of the HTS DC reactor for the arc furnace is much larger than most of HTS magnets and the enormous heat penetration through the current lead should be effectively removed to keep the temperature around 70∼77 K. Current leads are cooled down by circulation of liquid nitrogen from the cooling system with a stirling cryocooler. The operating temperature of HTS coil is 30∼40 K and circulation of gaseous helium is used to remove the heat generation at the HTS coil. Gaseous helium is transported through the cryogenic helium blower and a single stage GM cryocooler. This paper describes design and experimental results on the cooling system for current leads and the HTS coil of 5 kA, 200 μH class DC reactor as a prototype. The results are used to verify the design values of the cooling systems and it will be applied to the design of scale-up cooling system for 50 kA, 200 μH class DC reactor.

  3. Design research on the conductor of 10 kA class HTS DC power cable

    NASA Astrophysics Data System (ADS)

    Zhang, Dong; Dai, Shaotao; Zhang, Fengyuan; Huang, Tianbin; Wang, Yinshun; Lin, Yubao; Teng, Yuping; Zhang, Guomin; Xiao, Liye; Lin, Liangzhen

    2012-12-01

    High temperature superconducting (HTS) DC power cable shows a wide application prospect in the field of power transmission for its nearly lossless and rather high capacity. A 360 m/10 kA HTS DC power cable system, which connects the rectifier output of a substation with the bus bar of an electrolytic aluminium cell, will be put into operation at Henan Zhongfu Industrial Co., Ltd. As one of the items in this project, a 5 m/10 kA HTS DC power cable was developed, which is used to investigate the conductor design, fabrication, current-carrying capacity and stability of the 360 m/10 kA HTS power cable. The HTS DC power cable core consists of five conductor layers wound with spliced Bi-2223 wires with the length of 600 m. The cable core has five layers and 23 conductors in each layer with the outer diameter of 45.42 mm. The superconducting power cable is fabricated and tested. The critical current is about 14.3 kA at 77 K. The superconducting power cable is charged to 10 kA with rate of 10 A/s and operates at steady-state for 30 min. In this paper, the 10 kA HTS DC power cable design, fabrication and test are presented. The experimental research of the performance of spliced superconducting wire and charging, steady-state operating performance of the cable was carried out.

  4. The surface discharge and breakdown characteristics of HTS DC cable and stop joint box

    NASA Astrophysics Data System (ADS)

    Kim, W. J.; Kim, H. J.; Cho, J. W.; Kim, S. H.

    2014-09-01

    A high temperature superconducting (HTS) DC cable system consists of a HTS cable and cable joint. The HTS DC cable should be electrically connected in joint boxes because of the unit length of HTS cable is limited to several-hundred meters. In particular, the stop joint box (SJB) must be developed for a compact cooling system. Polypropylene laminated paper (PPLP) and epoxy maybe used as insulating materials for HTS DC cable and SJB. To develop a HTS DC cable, it is necessary to develop the cryogenic insulation technology, materials and the joint methods. In this paper, we will mainly discuss on the DC and impulse characteristics of epoxy and PPLP in liquid nitrogen (LN2). The surface discharge characteristics of epoxy included fillers, PPLP and epoxy with PPLP composite (epoxy + PPLP) were measured under 0.4 MPa. Also, the PPLP-insulated mini-model cable was fabricated and then DC, impulse and DC polarity reversal breakdown strength of mini-model cable under 0.4 MPa were investigated.

  5. Nonlinear buffer layers relevant for reduced nonlinear effects in HTS microwave devices

    NASA Astrophysics Data System (ADS)

    Seron, D.

    2008-02-01

    Microwave devices made of a High-Temperature Superconductor (HTS) exhibit a nonlinear response as the microwave power increases. The HTS nonlinearities generate a nonlinear inductance Ld(irf) and a nonlinear resistance Rd(irf) in a device. Ld(irf) and Rd(irf) are responsible for an increase of the device loss, a small frequency dispersion as well as the generation of spurious signals like Intermodulation Distortion (IMD). Nevertheless, the HTS nonlinearities in a microwave device can be reduced using a nonlinear dielectric like a ParaElectric Material (PEM). This assumption has recently been demonstrated theoretically. In a microwave device made of a HTS and a PEM, the nonlinear contribution to the capacitance Cd(vrf) from the PEM acts oppositely to the nonlinear contribution to Ld(irf). This may cancel the effect of the HTS inductive nonlinearities. The PEM also produces a nonlinear conductance Gd(vrf) in a device. All these nonlinear terms contribute to the IMD output power and the nonlinear quality factor (Q0) of a resonant passive microwave device. In this paper, the dependence of the different nonlinear contributions on frequency and applied dc bias voltage (Vdc) is investigated. The relevance to employ PEM in order to reduce the nonlinearities in HTS microwave devices is discussed.

  6. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  7. Study of the Nucleation and Growth of YBCO on Oxide Buffered Metallic Tapes

    SciTech Connect

    Solovyov, Vyacheslav

    2009-04-10

    The CRADA collaboration concentrated on developing the scientific understanding of the factors necessary for commercialization of high temperature superconductors (HTS) based on the YBCO coated conductor technology for electric power applications. The project pursued the following objectives: 1. Establish the correlations between the YBCO nuclei density and the properties of the CeO{sub 2} layer of the RABiTS{trademark} template; 2. Compare the nucleation and growth of e-beam and MOD based precursors on the buffered RABiTS{trademark} templates and clarify the materials science behind the difference; and 3. Explore routes for the optimization of the nucleation and growth of thick film MOD precursors in order to achieve high critical current densities in thick films. The CRADA work proceeded in two steps: 1. Detailed characterization of epitaxial ceria layers on “model” substrates, such as (001) YSZ and on RABiTS tapes; and 2. Study of YBCO nucleation on well-defined substrates and on long-length RABiTS.

  8. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 2 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 5 through 7. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139357), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). On flight day 5, the transfer and installation of a Power and Data Grapple Fixture onto the P6 Truss during an EVA (extravehicular activity) is shown. The relocation of micrometeorite debris shields is also shown. Canadarm 2 is used to move the Mobile Base System near the Mobile Transporter on the ISS Destiny Module. The capture of the Mobile Base System takes place on flight day 6, along with a crew transfer ceremony on board the ISS. The video includes a view of the South Pacific just before dawn, and the Endeavour crew answers questions from the public.

  9. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  10. Current Distribution in Wide YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Carrera, M.; Granados, X.; Amorós, J.; Puig, T.; Obradors, X.

    The need of a better mechanical behaviour and the stabilization of coated conductors for applications, as Magnets, cables or Fault Current Limiters, has motivated the lamination of tapes with stainless steel or copper alloys, increasing so the elastic modulus of the conductors and their mechanical performance. Some of the stainless steels used are magnetic, thus introducing some perturbations of the current flow when energizing the conductor. In order to detect these possible perturbations, the magnetic self field in the surface of the tape has been explored by Hall mapping technique at several current loads in a monotonically driven cyclic sequence. By increasing current steps when loading up, crossing the critical field threshold, and decreasing down to remanent state. Deviation from the expected magnetic map has been observed. In this work, we will report on the resulting measurements, and the current flow is calculated by solving the inverse problem for a 12 mm wide stainless steel reinforced Coated Conductor tape. We discuss on the likely origin of the observed perturbations.

  11. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  12. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  13. Triaxial HTS Cable for the AEP Bixby Project

    SciTech Connect

    Demko, Jonathan A; Gouge, Michael J; Lindsay, David T; Roden, Mark L; Tolbert, Jerry Carlton

    2007-01-01

    Ultera has installed a single 200-meter long high temperature superconducting (HTS) 3-phase triaxial design cable at the American Electric Power (AEP) Bixby substation in Columbus, Ohio. The cable connects a 132/13.8 kV transformer to the distribution switchgear serving seven outgoing circuits. It was designed to carry 3000 Arms. Testing of 3- to 5-meter length prototype cables, including a 5-meter prototype with full scale terminations tested at ORNL was conducted prior to the manufacture and installation of the AEP triaxial cable. These prototypes were used to demonstrate the crucial operating conditions including steady state operation at the 3000 Arms design current, high voltage operation, high voltage withstand and 110 kV impulse, and overcurrent fault capability. A summary of the results from the thermal analysis and testing conducted by Ultera and ORNL will be presented. Some analysis of the cable thermal-hydraulic response based on the testing that were used to determine some of the cable cryogenic system requirements are also presented.

  14. Heat Transfer Study for HTS Power Transfer Cables

    NASA Technical Reports Server (NTRS)

    Augustynowicz, S.; Fesmire, J.

    2002-01-01

    Thermal losses are a key factor in the successful application of high temperature superconducting (HTS) power cables. Existing concepts and prototypes rely on the use of multilayer insulation (MLI) systems that are subject to large variations in actual performance. The small space available for the thermal insulation materials makes the application even more difficult because of bending considerations, mechanical loading, and the arrangement between the inner and outer piping. Each of these mechanical variables affects the heat leak rate. These factors of bending and spacing are examined in this study. Furthermore, a maintenance-free insulation system (high vacuum level for 20 years or longer) is a practical requirement. A thermal insulation system simulating a section of a flexible FITS power cable was constructed for test and evaluation on a research cryostat. This paper gives experimental data for the comparison of ideal MLI, MLI on rigid piping, and MLI between flexible piping. A section of insulated flexible piping was tested under cryogenic vacuum conditions including simulated bending and spacers.

  15. Neon turbo-Brayton cycle refrigerator for HTS power machines

    NASA Astrophysics Data System (ADS)

    Hirai, Hirokazu; Hirokawa, M.; Yoshida, Shigeru; Nara, N.; Ozaki, S.; Hayashi, H.; Okamoto, H.; Shiohara, Y.

    2012-06-01

    We developed a prototype turbo-Brayton refrigerator whose working fluid is neon gas. The refrigerator is designed for a HTS (High Temperature Superconducting) power transformer and its cooling power is more than 2 kW at 65 K. The refrigerator has a turboexpander and a turbo-compressor, which utilize magnetic bearings. These rotational machines have no rubbing parts and no oil-components. Those make a long maintenance interval of the refrigerator. The refrigerator is very compact because our newly developed turbo-compressor is volumetrically smaller than a displacement type compressor in same operating specification. Another feature of the refrigerator is a wide range operation capability for various heat-loads. Cooling power is controlled by the input-power of the turbo-compressor instead of the conventional method of using an electric heater. The rotational speed of the compressor motor is adjusted by an inverter. This system is expected to be more efficient. We show design details, specification and cooling test results of the new refrigerator in this paper.

  16. Development of High Capacity Split Stirling Cryocooler for HTS

    NASA Astrophysics Data System (ADS)

    Yumoto, Kenta; Nakano, Kyosuke; Hiratsuka, Yoshikatsu

    Sumitomo Heavy Industries, Ltd. (SHI) developed a high-power Stirling-type pulse tube cryocooler for cooling high-temperature superconductor (HTS) devices, such as superconductor motors, superconducting magnetic energy storage (SMES), and fault current limiters. The experimental results of a prototype pulse tube cryocooler were reported in September 2013. For a U-type expander, the cooling capacity was 151 W at 70 K with a compressor input power of 4 kW. Correspondingly, the coefficient of performance (COP) was about 0.038. However, the efficiency of the cryocooler is required to be COP > 0.1 and it was found that, theoretically, it is difficult to further improve the efficiency of a pulse tube cryocooler because the workflow generated at the hot end of the pulse tube cannot be recovered. Therefore, it was decided to change the expander to a free-piston type from a pulse tube type. A prototype was developed and preliminary experiments were conducted. A cooling capacity of 120 W at 70 K with a compressor input power of 2.15 kW with corresponding COP of 0.056, was obtained. The detailed results are reported in this paper.

  17. A 5.9 tesla conduction-cooled coil composed of a stack of four single pancakes wound with YBCO wide tapes

    NASA Astrophysics Data System (ADS)

    Iwai, Sadanori; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke

    2013-11-01

    We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the Jc value of the tapes were almost the same as those of the former coil. At 77 K, the voltage-current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.

  18. Anisotropic shrinkage characteristics of tape cast alumina

    NASA Astrophysics Data System (ADS)

    Patwardhan, Jaideep Suresh

    Dimensional control during sintering is a major issue in ceramics processing to avoid high post-sintering costs associated with machining of the fired ceramic part to desired tolerances and dimensions. Ceramic forming processes such as tape casting, injection molding, and extrusion involve shear of anisotropic particles resulting in preferential alignment of the particles in the green body. This preferential alignment causes directionality in mechanical, electrical, optical, and magnetic properties and most importantly warpage or distortion during sintering. A large effort has been devoted to synthesizing ceramic green bodies with minimal density gradients and uniform packing and modeling the sintering behavior evolution but little effort has been devoted to characterizing orientation of particles and the effect of preferential alignment on sintering shrinkage anisotropy. A systematic study was initiated to study the effect of processing variables such as shear rate, solids loading, temperature, and binder content on aqueous tape cast alumina. Three different alumina systems: A16-SG, Baikowski RC-UFX DBM and RC-LS DBM were investigated. Aqueous tapes of high solids loading alumina (56 vol. %) were tape cast at various speeds and thicknesses and assuming plane Couette flow a shear rate regime of 21--270 s-1 was investigated. Higher shear rates and high solids loading resulted in higher in-plane anisotropy whereas the anisotropy in the thickness direction was higher for low solids loading systems. The anisotropy was found to be fairly constant above a certain critical shear rate (˜100 s-1) irrespective of the temperature and the solids loading and this correlated with the viscosity-shear rate relationship of the cast slips. The higher shrinkage anisotropy in the thickness direction for the low solids loading systems (35 and 45 vol. %) was attributed to the higher amount of organics in the slip required to sustain the suitable viscosity for tape casting and

  19. The Effect of Magnetic Field on HTS Leads What Happens when thePower Fails at RAL?

    SciTech Connect

    Green, Michael A.

    2007-02-14

    The key to being able to operate the MICE superconducting solenoids on small coolers is the use of high temperature superconducting (HTS) leads between the first stage of the cooler and the magnet, which operates at around 4.2 K. Because MICE magnets are not shielded, all of the MICE magnets have a stray magnetic field in the region where the coolers and the HTS leads are located. The behavior of the HTS leads in a magnetic field depends strongly on the HTS material used for the leads and the temperature of the cooler first stage temperature. The HTS leads can be specified to operate at the maximum current for the magnet. This report shows how the HTS leads can be specified for use the MICE magnets. MICE magnets take from 1.3 hours (the tracker solenoids) to 3.7 hours (the coupling magnet) to charge to the highest projected operating currents. If the power fails, the cooler and the upper ends of the HTS leads warm up. The question is how one can discharge the magnet to protect the HTS leads without quenching the MICE magnets. This report describes a method that one can use to protect the HTS leads in the event of a power failure at the Rutherford Appleton Laboratory (RAL).

  20. Specification for IBM/IBM compatible 3480 tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    This document establishes the same kinds of standards and controls that are currently in use for the procurement on new analog and digital magnetic tapes. The Magnetic Tape Certification Facility (MTCF) currently maintains a Quality Products List (QPL) for all new analog and digital magnetic tapes purchased by NASA-GSFC. Extensive tests are conducted in the MTCF on an annual basis to determine the manufacturer's tape types to be added to or deleted from the current QPL. The MTCF currently maintains two specifications for magnetic tapes: NASA TM-79724 is used for the QPL and acceptance testing of new analog tapes; and NASA TM-80599 is used for the QPL and acceptance testing of new digital tapes. This specification will be used for the QPL and acceptance testing of new 3480 cartridges. The magnetic tapes used by GSFC, LaRC, ARC/Dryden, WFF, and the Network Tracking Stations are covered by the NASA-GSFC specifications. The 3480 cartridge was introduced approximately 3.5 years ago and is becoming an increasingly attractive alternative to digital magnetic tapes. Many users have already converted to the 3480 system and have more tape drives on order.

  1. A Proposed Convention for Writing FITS Data Tapes: DRAFT 0

    NASA Astrophysics Data System (ADS)

    ROSAT/ASCA/Xte Development Team

    Even with today's advances in networking, file system capacities and CD technology it is often necessary to transport and store scientific data sets on magnetic tape. The FITS data format standard contains guidelines on how to write FITS files to magnetic tape but does not address the problem of indexing or organizing tape files. Currently available magnetic tape media can store multiple gigabytes of information on a single tape, which translates into thousands of FITS files per tape. Thus, the lack of a standard tape indexing and organizing scheme can, in many instances, become a serious problem. Faced with the above dilemma, the Astrophysics Data Facility at Goddard Space Flight Center has developed a simple in-house convention for indexing the contents of FITS data tapes that allows software to quickly and easily inventory tape contents. This paper describes the convention used by our organization. We propose that this convention be adopted into the FITS standard as the way to index and organize the contents of magnetic tape media.

  2. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  3. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis.

    PubMed

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  4. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    PubMed Central

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  5. Status and Progress of a Fault Current Limiting Hts Cable to BE Installed in the con EDISON Grid

    NASA Astrophysics Data System (ADS)

    Maguire, J.; Folts, D.; Yuan, J.; Henderson, N.; Lindsay, D.; Knoll, D.; Rey, C.; Duckworth, R.; Gouge, M.; Wolff, Z.; Kurtz, S.

    2010-04-01

    In the last decade, significant advances in the performance of second generation (2G) high temperature superconducting wire have made it suitable for commercially viable applications such as electric power cables and fault current limiters. Currently, the U.S. Department of Homeland Security is co-funding the design, development and demonstration of an inherently fault current limiting HTS cable under the Hydra project with American Superconductor and Consolidated Edison. The cable will be approximately 300 m long and is being designed to carry 96 MVA at a distribution level voltage of 13.8 kV. The underground cable will be installed and energized in New York City. The project is led by American Superconductor teamed with Con Edison, Ultera (Southwire and nkt cables joint venture), and Air Liquide. This paper describes the general goals, design criteria, status and progress of the project. Fault current limiting has already been demonstrated in 3 m prototype cables, and test results on a 25 m three-phase cable will be presented. An overview of the concept of a fault current limiting cable and the system advantages of this unique type of cable will be described.

  6. Electrical performance analysis of HTS synchronous motor based on 3D FEM

    NASA Astrophysics Data System (ADS)

    Baik, S. K.; Kwon, Y. K.; Kim, H. M.; Lee, J. D.; Kim, Y. C.; Park, G. S.

    2010-11-01

    A 1-MW class superconducting motor with High-Temperature Superconducting (HTS) field coil is analyzed and tested. This machine is a prototype to make sure applicability aimed at generator and industrial motor applications such as blowers, pumps and compressors installed in large plants. This machine has the HTS field coil made of Bi-2223 HTS wire and the conventional copper armature (stator) coils cooled by water. The 1-MW class HTS motor is analyzed by 3D electromagnetic Finite Element Method (FEM) to get magnetic field distribution, self and mutual inductance, and so forth. Especially excitation voltage (Back EMF) is estimated by using the mutual inductance between armature and field coils and compared with experimental result. Open and short circuit tests were conducted in generator mode while a 1.1-MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests and also compared with the analysis results from FEM.

  7. MScreen: An Integrated Compound Management and High Throughput Screening (HTS) Data Storage and Analysis System

    PubMed Central

    Jacob, Renju T.; Larsen, Martha J.; Larsen, Scott D.; Kirchhoff, Paul D.; Sherman, David H.; Neubig, Richard R.

    2013-01-01

    High-throughput screening (HTS) has historically been used by the pharmaceutical industry to rapidly test hundreds of thousands of compounds to identify potential drug candidates. More recently, academic groups have used HTS to identify new chemical probes or small interfering RNA (siRNA) that can serve as experimental tools to examine the biology or physiology of novel proteins, processes, or interactions. HTS presents a significant challenge with the vast and complex nature of data generated. This report describes MScreen, a web-based, open-source cheminformatics application for chemical library and siRNA plate management, primary HTS and dose-response data handling, structure search, and administrative functions. Each project in MScreen can be secured with passwords or shared in an open information environment which enables collaborators to easily compare data from many screens, providing a useful means to identify compounds with desired selectivity. Unique features include compound, substance, mixture, and siRNA plate creation and formatting; automated dose-response fitting and quality control (QC); and user, target, and assay method administration. MScreen provides an effective means to facilitate HTS information handling and analysis in the academic setting so that users can efficiently view their screening data and evaluate results for follow-up. PMID:22706349

  8. Developing scientific confidence in HTS-derived prediction models: lessons learned from an endocrine case study.

    PubMed

    Cox, Louis Anthony; Popken, Douglas; Marty, M Sue; Rowlands, J Craig; Patlewicz, Grace; Goyak, Katy O; Becker, Richard A

    2014-08-01

    High throughput (HTS) and high content (HCS) screening methods show great promise in changing how hazard and risk assessments are undertaken, but scientific confidence in such methods and associated prediction models needs to be established prior to regulatory use. Using a case study of HTS-derived models for predicting in vivo androgen (A), estrogen (E), thyroid (T) and steroidogenesis (S) endpoints in endocrine screening assays, we compare classification (fitting) models to cross validation (prediction) models. The more robust cross validation models (based on a set of endocrine ToxCast™ assays and guideline in vivo endocrine screening studies) have balanced accuracies from 79% to 85% for A and E, but only 23% to 50% for T and S. Thus, for E and A, HTS results appear promising for initial use in setting priorities for endocrine screening. However, continued research is needed to expand the domain of applicability and to develop more robust HTS/HCS-based prediction models prior to their use in other regulatory applications. Based on the lessons learned, we propose a framework for documenting scientific confidence in HTS assays and the prediction models derived therefrom. The documentation, transparency and the scientific rigor involved in addressing the elements in the proposed Scientific Confidence Framework could aid in discussions and decisions about the prediction accuracy needed for different applications. PMID:24845243

  9. AC HTS Transmission Cable for Integration into the Future EHV Grid of the Netherlands

    NASA Astrophysics Data System (ADS)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Aanhaanen, G.; Melnik, I.; Geschiere, A.

    Due to increasing power demand, the electricity grid of the Netherlands is changing. The future grid must be capable to transmit all the connected power. Power generation will be more decentralized like for instance wind parks connected to the grid. Furthermore, future large scale production units are expected to be installed near coastal regions. This creates some potential grid issues, such as: large power amounts to be transmitted to consumers from west to east and grid stability. High temperature superconductors (HTS) can help solving these grid problems. Advantages to integrate HTS components at Extra High Voltage (EHV) and High Voltage (HV) levels are numerous: more power with less losses and less emissions, intrinsic fault current limiting capability, better control of power flow, reduced footprint, etc. Today's main obstacle is the relatively high price of HTS. Nevertheless, as the price goes down, initial market penetration for several HTS components is expected by year 2015 (e.g.: cables, fault current limiters). In this paper we present a design of intrinsically compensated EHV HTS cable for future grid integration. Discussed are the parameters of such cable providing an optimal power transmission in the future network.

  10. Integration of HTS Cables in the Future Grid of the Netherlands

    NASA Astrophysics Data System (ADS)

    Zuijderduin, R.; Chevtchenko, O.; Smit, J. J.; Aanhaanen, G.; Melnik, I.; Geschiere, A.

    Due to increasing power demand, the electricity grid of the Netherlands is changing. The future transmission grid will obtain electrical power generated by decentralized renewable sources, together with large scale generation units located at the coastal region. In this way electrical power has to be distributed and transmitted over longer distances from generation to end user. Potential grid issues like: amount of distributed power, grid stability and electrical loss dissipation merit particular attention. High temperature superconductors (HTS) can play an important role in solving these grid problems. Advantages to integrate HTS components at transmission voltages are numerous: more transmittable power together with less emissions, intrinsic fault current limiting capability, lower ac loss, better control of power flow, reduced footprint, less magnetic field emissions, etc. The main obstacle at present is the relatively high price of HTS conductor. However as the price goes down, initial market penetration of several HTS components (e.g.: cables, fault current limiters) is expected by year 2015. In the full paper we present selected ways to integrate EHV AC HTS cables depending on a particular future grid scenario in the Netherlands.

  11. Influence of radius of cylinder HTS bulk on guidance force in a maglev vehicle system

    NASA Astrophysics Data System (ADS)

    Longcai, Zhang

    2014-07-01

    Bulk superconductors had great potential for various engineering applications, especially in a high-temperature superconducting (HTS) maglev vehicle system. In such a system, the HTS bulks were always exposed to AC external magnetic field, which was generated by the inhomogeneous surface magnetic field of the NdFeB guideway. In our previous work, it was observed that the guidance force of the YBCO bulk over the NdFeB guideway used in the HTS maglev vehicle system was decayed by the application of the AC external magnetic field. In this paper, we investigated the influence of the radius of the cylinder HTS bulk exposed to an AC magnetic field perturbation on the guidance force in the maglev vehicle system. From the results, it was found that the guidance force was stronger for the bulk with bigger radius and the guidance force decay rates of the bulks were approximately equal despite of the different radius in the maglev vehicle system. Therefore, in order to obtain higher guidance force in the maglev vehicle system, we could use the cylinder HTS bulks with the bigger radius.

  12. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  13. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  14. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  15. Printed-Circuit Tape Measures For X-Ray Inspections

    NASA Technical Reports Server (NTRS)

    Sullivan, John E., Jr.

    1990-01-01

    Known pattern impressed on x-ray image for reference. Tapes made by flexible-printed-circuit technology provides identification and position references for x-ray images of weld joints. Proposed tapes consist of etched copper patterns on flexible substrates. X-rays record pattern of tape on film beneath butt-welded panels. Pattern becomes convenient reference for analysis and digitization of x-ray image.

  16. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  17. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  18. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  19. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  20. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  1. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary; Brosha, Eric L.; Garzon, Fernando H.

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  2. Electromechanical characterization of silver-clad BSCCO tapes.

    SciTech Connect

    Salib, S.; Iyer, A. N.; Vipulanandan, C.; Salama, K.; Balachandran, U.; Energy Technology; Univ. of Houston

    1998-01-01

    During the fabrication of silver-clad BSCCO tapes they are subjected to stresses which could lead to degradation in their current transport property. In the present investigation, studies were made to evaluate the electromechanical characteristics of silver-clad BSCCO conductors. The tensile strain tolerance characteristics of the monofilament, multifilament and composite (15 and 30% of Ag powder by volume) tapes were evaluated at 77 K. The average irreversible strain of monofilament and composite tapes were 0.19 and 0.47%, respectively. No noticeable improvement in strain tolerance was observed with the multifilament tapes. Detailed phase and microstructural analysis have been conducted using scanning electron microscopy.

  3. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  4. Contact Recording on Bidirectional Thin-Film Tape Head Structures

    NASA Astrophysics Data System (ADS)

    Brock, George W.; Connolly, Derry; Czarnecki, W. Stanley

    A transversely slotted magnetic recording head for high density tape drives is characterized theoretically for geometry and experimentally for wear and durability under different environmental conditions, tape substrate thicknesses, recording head substrate materials, and wear resistant overcoat materials. The triple bump recording head structure, which allows read-after-write in both directions of tape motion, has transverse slots placed in the head to produce contact between the tape and the read/write gap locations. A through slot "video" style contour design is also presented and analyzed.

  5. Slide Tape. A Guide to the Production of Slide-Tape Programmes.

    ERIC Educational Resources Information Center

    Rowatt, Robert W.

    Step by step instructions are provided for planning and executing a slide tape program, as well as diagrams of equipment for presenting such programs. Guidelines are given for ways to: (1) define a program's purpose and objectives, (2) complete a storyboard, (3) produce slides from transparencies and photographed artwork, (4) write on slides, (5)…

  6. Recording electrophysiological data on video tape: a superior and less costly alternative to conventional tape recorders.

    PubMed

    Chiang, R G; Knobloch, C A; Singleton, D M; Steel, C G; Davey, K G

    1985-10-01

    Electrical potentials recorded extracellularly from the sinus gland of the isopod, Oniscus asellus, were stored on video tape with the aid of a digital-audio (DA) processor and a video cassette recorder (VCR). The DA processor transforms the analog signal to digital pulses of equal amplitude and converts these pulses into a television signal for recording on video tape. In playback, the DA processor reconverts the pulses to an analog signal with negligible distortion. When viewed on the oscilloscope screen, electrical potentials reproduced by this method were indistinguishable from electrical potentials recorded 'live' from the sinus gland. However, electrical potentials recorded from the same sinus gland and reproduced by a conventional FM tape recorder were easily differentiated from the 'live' recording. The special effects inherent in the VCR (e.g. stop action, frame advance) also permitted detailed analysis of spontaneously occurring electrical potentials. Special effects were not possible with the FM tape recorder. The price, ease of operation and ability to produce extremely high quality recordings, makes the DA processor and VCR an exceptional system for storing electrophysiological data. PMID:4058060

  7. The Role of HTS in Drug Discovery at the University of Michigan

    PubMed Central

    Larsen, Martha J.; Larsen, Scott D.; Fribley, Andrew; Grembecka, Jolanta; Homan, Kristoff; Mapp, Anna; Haak, Andrew; Nikolovska-Coleska, Zaneta; Stuckey, Jeanne A.; Sun, Duxin

    2014-01-01

    High throughput screening (HTS) is an integral part of a highly collaborative approach to drug discovery at the University of Michigan. The HTS lab is one of four core centers that provide services to identify, produce, screen and follow-up on biomedical targets for faculty. Key features of this system are: protein cloning and purification, protein crystallography, small molecule and siRNA HTS, medicinal chemistry and pharmacokinetics. Therapeutic areas that have been targeted include anti-bacterial, metabolic, neurodegenerative, cardiovascular, anti-cancer and anti-viral. The centers work in a coordinated, interactive environment to affordably provide academic investigators with the technology, informatics and expertise necessary for successful drug discovery. This review provides an overview of these centers at the University of Michigan, along with case examples of successful collaborations with faculty. PMID:24409957

  8. Reliability Test of a 1-kW Pulse Tube Cryocooler for Hts Cable Application

    NASA Astrophysics Data System (ADS)

    Chen, R.-L.; Henzler, G. W.; Royal, J. H.; Billingham, J. F.

    2010-04-01

    The recent progress of a large Stirling-type pulse tube cryocooler is reported based on 24/7 operation since August 2008 in a high temperature superconducting (HTS) cable application at American Electric Power's (AEP) Bixby Road substation in Columbus, OH. The 20-kW pressure wave generator (PWG) has been upgraded to a second generation design. The in-line configured pulse tube coldhead, rated at 1 kW at 77 K, was developed by Praxair. The objective of the continued testing at the HTS cable demonstration facility is to accumulate cryocooler operating hours and demonstrate system reliability. The cryocooler uses a parallel flow from the main vacuum subcooling refrigerator then both flows are supplied to the HTS cable inlet. The cryocooler operation has shown consistent results with satisfactory cooling performance. The field demonstrated thermodynamic efficiency is 15% of Carnot at 72 K.

  9. Low Temperature Performance of a Boost Converter with MPP and HTS Inductors

    NASA Technical Reports Server (NTRS)

    Ray, Biswajit; Gerber, Scott S.; Patterson, Richard L.; Dickman, John E.

    1996-01-01

    Low temperature performance of a 150 W, 50 kHz, 24/48 V boost PWM dc-to-dc converter is reported. The efficiency of the converter using a molypermalloy powder (MPP) core based inductor went up from 94% at room temperature (23 C) to 95.9% at liquid nitrogen temperature (-196 C). A BSCCO based high temperature superconducting (HTS) inductor with a transition temperature of approximately -158 C was compared to a MPP core based inductor in terms of the power converter performance at liquid nitrogen temperature. The use of the HTS inductor in the converter tested yielded no significant performance improvement over the same converter with the MPP inductor. The experimental results are discussed along with the HTS inductor characteristics.

  10. The Dynamic Characteristics on the Wall Traveling of the HTS Bulk Superconducting Actuator

    NASA Astrophysics Data System (ADS)

    Sawae, M.; Kim, S. B.; Ozasa, S.; Nakano, H.; Kobayashi, H.

    The electric device applications of a high temperature superconducting (HTS) bulk having stable levitation and suspension properties due to their strong flux pinning force have been proposed and developed. We have been investigating the three-dimensional (3-D) superconducting actuator using HTS bulk to develop the transportation device with non-contact and moves in free space. It is expected that our proposed 3-D superconducting actuator to be useful as a transporter used in clean room which manufactures the silicon wafer where dislikes mechanical contact and dust. Proposed the actuator consists of a field-cooled HTS bulk for mover and two-dimensional arranged multiple electromagnets as a stator. In our previous study, the dynamic characteristics on the floor traveling of the HTS bulk mover had been studied. Therefore in this study, a system for the wall traveling was proposed to use the limited space effectively. It is expected that the wall traveling system is very useful to apply the transporter used in the tunnels which flammable gas may be produced. In this paper, the optimal angle between electromagnets located at floor and wall for moving to the wall traveling from the floor traveling was investigated experimentally. The position displacement on the rotating of the HTS bulk during the wall traveling was measured. As a result, the bulk with initial gap of 2 mm could move to the wall traveling from the floor traveling. Also, the position displacement on the height direction during the rotating of the HTS bulk was 18 mm from the initial position because of its gravity,but it was possible to rotate by changing the pattern NSNS of the trapped magnetic field in near the initial position.

  11. Performance of the BG1Luc ER TA method in a qHTS format.

    PubMed

    Ceger, Patricia; Allen, David; Huang, Ruili; Xia, Menghang; Casey, Warren

    2015-01-01

    In 2012, the BG1Luc4E2 estrogen receptor (ER) transactivation (TA) method (BG1Luc ER TA) was accepted by U.S. regulatory agencies and the Organisation for Economic Co-operation and Development to detect substances with ER agonist activity. The method is now part of the Tier 1 testing battery in the Environmental Protection Agency's Endocrine Disruptor Screening Program. The BG1Luc ER TA method uses the BG1 ovarian cell line that endogenously expresses full-length ER (α and β) and is stably transfected with a plasmid containing four estrogen responsive elements upstream of a luciferase reporter gene. To allow increased throughput and testing efficiency, the BG1Luc ER TA ("BG1 manual") method was adapted for quantitative high-throughput screening (BG1 qHTS) in the U.S. Tox21 testing program. The BG1 qHTS test method was used to test approximately 10,000 chemicals three times each, and concentration-response data (n=15) were analyzed to evaluate test method performance. The balanced accuracy of the BG1 qHTS test method (97% [32/33]) was determined by comparing results to ER TA performance standards for the BG1 manual method. Concordance between the BG1 manual and qHTS methods was 92% (57/62) when calculated for a larger set of non-reference chemicals tested in both methods. These data demonstrate that the performance of the BG1 qHTS is similar to the currently accepted BG1 manual method, thereby establishing the utility of the BG1 qHTS method for identifying ER active environmental chemicals. PMID:26117232

  12. Fabrication and characterization of Ag-clad Bi-2223 tapes.

    SciTech Connect

    Balachandran, U.

    1999-04-20

    The powder-in-tube (PIT) technique was used to fabricate multifilament (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes. Transport current properties of these tapes were enhanced by increasing the packing density of the precursor powder and improving the mechanical deformation condition. A critical current (I{sub c}) of > 35 A in long lengths (> 200 m) tapes has been achieved. In measuring the dependence of critical current density on magnetic field and temperature for the optimally processed tapes, we found a J{sub c} of > 10{sup 4} A/cm{sup 2} at 20 K in magnetic fields up to 3 T and parallel to the c-axis, which is of interest for use in refrigerator-cooled magnets. I{sub c} declined exponentially when an external field was applied perpendicular to the tape surface at 77 K. Mechanical stability was tested for tapes sheathed with pure Ag and Ag-Mg alloy. Tapes made with pure Ag sheathing can withstand a tensile stress of {approx}20 MPa with no detrimental effect on I{sub c} values. Mechanical performance was improved by using Ag-Mg alloy sheathing: values of transport critical current began to decrease at the tensile stress of {approx} 100 MPa. Transport current measurements on tapes wound on a mandrel of 3.81 cm (1.5 in.) diameter at 30{degree} to the longitudinal axis, showed a reduction of {approx} 10% in I{sub c} values for pure Ag-sheathed tapes and 5% reduction in I{sub c} values for Ag-Mg sheathed tapes, compared with the I{sub c} values of as-coiled tapes.

  13. Levitation or suspension: Which one is better for the heavy-load HTS maglev transportation

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Kang, Dong; Yang, X. F.; Wang, Fei; Peng, G. H.; Zheng, Jun; Ma, G. T.; Wang, J. S.

    2015-09-01

    Because of the limitation of permanent magnet (PM), the efficient of bulk high-Tc superconductor (HTSC) in a high-Tc superconducting (HTS) maglev system is not very high. It is better to magnetize the bulk HTSC with a high trapped field to increase the force density. The different application type of magnetized bulk HTSC in a maglev system, namely, levitation or suspension type, will bring quite different operation performance. This paper discusses the influence of application type on operation performance of magnetized bulk HTSC by experiments and simulations. From the discussion, it can be found which application type is better for the heavy-load HTS maglev system.

  14. A computer-aided method for postproduction tuning of HTS filters

    NASA Astrophysics Data System (ADS)

    Zuo, Tao; Fang, Lan; Yan, Shaolin; Zhao, Xinjie; Zhou, Tiege; You, Shitou; Ma, Weigang; Yue, Hongwei; Xie, Qinglian

    2007-12-01

    The empirical tuning of high temperature superconducting (HTS) filters is usually time-consuming and expensive. A computer-aided tuning method is presented in this paper. By means of optimization, the method diagnoses detuning of individual resonators quantitatively in the tuning process, and then by using neural network models the method is able to give the operator a decision on how much the corresponding tuning screws should be tuned. So, compared with the empirical tuning method, this method can be used to tune the HTS filters accurately with less time and cost.

  15. A study on insulation characteristics according to cooling methods of the HTS SMES

    NASA Astrophysics Data System (ADS)

    Choi, J. H.; Cheon, H. G.; Choi, J. W.; Kim, H. J.; Seong, K. C.; Kim, S. H.

    2010-11-01

    The high temperature superconducting magnetic energy storage (HTS SMES) stores electric power in the form of magnetic energy, and then converts it to electric energy. For the operation, the HTS SMES must have a cryogenic temperature. The cooling methods for a cryogenic temperature are divided into an immersed method and a conduction cooled method. The immersed method is a direct cooling method that immerses the superconducting magnet into a cryogen. On the other hand, the conduction cooled method is an indirect cooling method that cools a superconductor through thermal conduction with a cryocooler. This paper classified the structures of insulation according to cooling methods, and studied the insulation characteristics of each insulation factor.

  16. The adipocyte-inducible secreted phospholipases PLA2G5 and PLA2G2E play distinct roles in obesity.

    PubMed

    Sato, Hiroyasu; Taketomi, Yoshitaka; Ushida, Ayako; Isogai, Yuki; Kojima, Takumi; Hirabayashi, Tetsuya; Miki, Yoshimi; Yamamoto, Kei; Nishito, Yasumasa; Kobayashi, Tetsuyuki; Ikeda, Kazutaka; Taguchi, Ryo; Hara, Shuntaro; Ida, Satoshi; Miyamoto, Yuji; Watanabe, Masayuki; Baba, Hideo; Miyata, Keishi; Oike, Yuichi; Gelb, Michael H; Murakami, Makoto

    2014-07-01

    Metabolic disorders, including obesity and insulin resistance, have their basis in dysregulated lipid metabolism and low-grade inflammation. In a microarray search of unique lipase-related genes whose expressions are associated with obesity, we found that two secreted phospholipase A2s (sPLA2s), PLA2G5 and PLA2G2E, were robustly induced in adipocytes of obese mice. Analyses of Pla2g5(-/-) and Pla2g2e(-/-) mice revealed distinct roles of these sPLA2s in diet-induced obesity. PLA2G5 hydrolyzed phosphatidylcholine in fat-overladen low-density lipoprotein to release unsaturated fatty acids, which prevented palmitate-induced M1 macrophage polarization. As such, PLA2G5 tipped the immune balance toward an M2 state, thereby counteracting adipose tissue inflammation, insulin resistance, hyperlipidemia, and obesity. PLA2G2E altered minor lipoprotein phospholipids, phosphatidylserine and phosphatidylethanolamine, and moderately facilitated lipid accumulation in adipose tissue and liver. Collectively, the identification of "metabolic sPLA2s" adds this gene family to a growing list of lipolytic enzymes that act as metabolic coordinators.

  17. Tape It! Using Audio Tapes as an Integral Part of a Multi-Media, Multi-Material Approach to Social Studies in the Intermediate Grades

    ERIC Educational Resources Information Center

    Gerlach, Gail J.

    1977-01-01

    Describes the use of audio tapes in the social studies classroom. Topics discussed include: using commercial learning aids, using the audio tape, taping directions, accommodating reading levels, recording current events, preparing students to use equipment, and using the tapes for evaluation. For journal availability, see SO 505 448. (Author/DB)

  18. The Effects of Patellar Taping on Knee Joint Proprioception

    PubMed Central

    Callaghan, Michael J.; Selfe, James; Bagley, Pam J.; Oldham, Jacqueline A.

    2002-01-01

    Objective: To evaluate the effects of patellar taping on knee joint proprioception. Design and Setting: In a research unit, 3 proprioceptive tests were performed. For each of the tests, a standardized patellar taping technique was applied in random order. Subjects: Fifty-two healthy volunteers (27 women, 25 men; age, 23.2 ± 4.6 years; body mass index, 23.3 ± 3.7). Measurements: We measured active angle reproduction, passive angle reproduction, and threshold to detection of passive movement on an isokinetic dynamometer. Results: We found no significant differences between the tape and no-tape conditions in any of the 3 proprioceptive tests (P > .05). However, when the subjects' results for active angle reproduction and passive angle reproduction were graded as good (≤5°) and poor (>5°), taping was found to improve significantly those with poor proprioceptive ability (P < .01). Conclusions: Subjects with good proprioception did not benefit from patellar taping. However, in those healthy subjects with poor proprioceptive ability as measured by active and passive ankle reproduction, patellar taping provided proprioceptive enhancement. Further studies are needed to investigate the effect of patellar taping on the proprioceptive status of patients with patellofemoral pain syndrome. PMID:12937439

  19. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide historical…

  20. Using a Taped Intervention to Improve Kindergarten Students' Number Identification

    ERIC Educational Resources Information Center

    Krohn, Katherine R.; Skinner, Christopher H.; Fuller, Emily J.; Greear, Corrine

    2012-01-01

    A multiple baseline design across students was used to evaluate the effects of a taped numbers (TN) intervention on the number-identification accuracy of 4 kindergarten students. During TN, students attempted to name the numbers 0 through 9 on randomized lists before each number was provided via a tape player 2 s later. All 4 students showed…

  1. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  2. Equilibrium states and stability of pre-tensioned adhesive tapes

    PubMed Central

    Putignano, Carmine; Afferrante, Luciano; Mangialardi, Luigi

    2014-01-01

    Summary In the present paper we propose a generalization of the model developed in Afferrante, L.; Carbone, G.; Demelio, G.; Pugno, N. Tribol. Lett. 2013, 52, 439–447 to take into account the effect of the pre-tension in the tape. A detailed analysis of the peeling process shows the existence of two possible detachment regimes: one being stable and the other being unstable, depending on the initial configuration of the tape. In the stability region, as the peeling process advances, the peeling angle reaches a limiting value, which only depends on the geometry, on the elastic modulus of the tape and on the surface energy of adhesion. Vice versa, in the unstable region, depending on the initial conditions of the system, the tape can evolve towards a state of complete detachment or fail before reaching a state of equilibrium with complete adhesion. We find that the presence of pre-tension in the tape does not modify the stability behavior of the system, but significantly affects the pull-off force which can be sustained by the tape before complete detachment. Moreover, above a critical value of the pre-tension, which depends on the surface energy of adhesion, the tape will tend to spontaneously detach from the substrate. In this case, an external force is necessary to avoid spontaneous detachment and make the tape adhering to the substrate. PMID:25383283

  3. The Effects of Patellar Taping on Knee Joint Proprioception.

    PubMed

    Callaghan, Michael J; Selfe, James; Bagley, Pam J; Oldham, Jacqueline A

    2002-03-01

    OBJECTIVE: To evaluate the effects of patellar taping on knee joint proprioception. DESIGN AND SETTING: In a research unit, 3 proprioceptive tests were performed. For each of the tests, a standardized patellar taping technique was applied in random order. SUBJECTS: Fifty-two healthy volunteers (27 women, 25 men; age, 23.2 +/- 4.6 years; body mass index, 23.3 +/- 3.7). MEASUREMENTS: We measured active angle reproduction, passive angle reproduction, and threshold to detection of passive movement on an isokinetic dynamometer. RESULTS: We found no significant differences between the tape and no-tape conditions in any of the 3 proprioceptive tests (P >.05). However, when the subjects' results for active angle reproduction and passive angle reproduction were graded as good (5 degrees ), taping was found to improve significantly those with poor proprioceptive ability (P <.01). CONCLUSIONS: Subjects with good proprioception did not benefit from patellar taping. However, in those healthy subjects with poor proprioceptive ability as measured by active and passive ankle reproduction, patellar taping provided proprioceptive enhancement. Further studies are needed to investigate the effect of patellar taping on the proprioceptive status of patients with patellofemoral pain syndrome.

  4. Low-cost tape system measures velocity of acceleration

    NASA Technical Reports Server (NTRS)

    Hartenstein, R.

    1964-01-01

    By affixing perforated magnetic recording tape to the falling end of a body, acceleration and velocity were measured. The measurement was made by allowing the tape to pass between a light source and a photoelectric sensor. Data was obtained from a readout device.

  5. Tape-Drive Based Plasma Mirror

    SciTech Connect

    Sokollik, Thomas; Shiraishi, Satomi; Osterhoff, Jens; Evans, Eugene; Gonsalves, Anthony; Nakamura, Kei; vanTilborg, Jeroen; Lin, Chen; Toth, Csaba; Leemans, Wim

    2011-07-22

    We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots. In order to design a compact, staged laser plasma based accelerator or collider [1], the coupling of the laser beam into the different stages represents one of the key issues. To limit the spatial foot print and thus to realize a high overall acceleration gradient, a concept has to be found which realizes this in-coupling within a few centimeters (cf. Fig 1). The fluence of the laser pulse several centimeters away from the acceleration stage (focus) exceeds the damage threshold of any available mirror coating. Therefore, in reference [2] a plasma mirror was suggested for this purpose. We present experiments on a tape-drive based plasma mirror which could be used to reflect the focused laser beam into the acceleration stage. Plasma mirrors composed of antireflection coated glass substrates are usually used to improve the temporal laser contrast of laser pulses by several orders of magnitudes [3,4]. This is particularly important for laser interaction with solid matter, such as ion acceleration [5,6] and high harmonic generation on surfaces [7]. Therefore, the laser pulse is weekly focused onto a substrate. The main pulse generates a plasma and is reflected at the critical surface, whereas the low intensity pre-pulse (mainly the Amplified Spontaneous Emission pedestal) will be transmitted through the substrate before the mirror has been triggered. Several publications [3,4] demonstrate a conservation of the spatial beam quality and a reflectivity of about 70 %. The drawback of this technique is the limited repetition rate since for every shot a fresh surface has to be provided. In the past years several novel approaches for high repetition rate plasma mirrors have been developed [2, 8

  6. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  7. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  8. Intercomputer transfer in full precision of arbitrary data on magnetic tape employing NASTRAN user tape format

    NASA Technical Reports Server (NTRS)

    Rogers, J. L., Jr.

    1973-01-01

    A description is presented of two new utility programs which implement the transfer, in full precision, of arbitrary data (matrices or tables) between any of the three NASTRAN operative computers without the handling of large card decks. These computers include the CDC 6000 series, the IBM 360-370 series, and the Univac 1100 series. The data may be generated by NASTRAN or by another computer program if the NASTRAN user tape format is employed.

  9. Pathway Profiling and Tissue Modeling Using ToxCast HTS Data

    EPA Science Inventory

    High-throughput screening (HTS) and high-content screening (HCS) assays are providing data-rich studies to probe and profile the direct cellular effects of thousands of chemical compounds in commerce or potentially entering the environment. In vitro profiling may compare unknown ...

  10. Predictive Signatures of Developmental Toxicity Modeled with HTS Data from ToxCast™ Bioactivity Profiles

    EPA Science Inventory

    The EPA ToxCast™ research program uses a high-throughput screening (HTS) approach for predicting the toxicity of large numbers of chemicals. Phase-I contains 309 well-characterized chemicals which are mostly pesticides tested in over 600 assays of different molecular targets, cel...

  11. Nanomaterial (NM) bioactivity profiling by ToxCast high-throughput screening (HTS)

    EPA Science Inventory

    Rapidly increasing numbers of new NMs and their uses demand efficient tests of NM bioactivity for safety assessment. The EPA’s ToxCast program uses HTS assays to prioritize for targeted testing, identify biological pathways affected, and aid in linking NM properties and potential...

  12. Thermal Insulation Performance of Flexible Piping for Use in HTS Power Cables

    NASA Technical Reports Server (NTRS)

    Fesmire, James E.; Augustynowicz, S. D.; Demko, J. A.; Thompson, Karen (Technical Monitor)

    2001-01-01

    High-temperature superconducting (HTS) cables that typically operate at temperatures below 80 K are being developed for power transmission. The practical application of HTS power cables will require the use of flexible piping to contain the cable and the liquid nitrogen coolant. A study of thermal performance of multilayer insulation (MLI) was conducted in geometries representing both rigid and flexible piping. This experimental study performed at the Cryogenics Test Laboratory of NASA Kennedy Space Center provides a framework for the development of cost-effective, efficient thermal insulation systems that will support these long-distance flexible lines containing HTS power cables. The overall thermal performance of the insulation system for a rigid configuration and for a flexible configuration, simulating a flexible HTS power cable, was determined by the steady-state liquid nitrogen boiloff method under the full range of vacuum levels. Two different cylindrically rolled material systems were tested: a standard MLI and a layered composite insulation (LCI). Comparisons of ideal MLI, MLI on rigid piping, and MLI between flexible piping are presented.

  13. Assessment of High Temperature Superconducting (HTS) electric motors for rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Doernbach, Jay

    1990-01-01

    The successful development of high temperature superconductors (HTS) could have a major impact on future aeronautical propulsion and aeronautical flight vehicle systems. Applications of high temperature superconductors have been envisioned for several classes of aeronautical systems, including subsonic and supersonic transports, hypersonic aircraft, V/STOL aircraft, rotorcraft and solar powered aircraft. The potential of HTS electric motors and generators for providing primary shaft power for rotorcraft propulsion is examined. Three different sized production helicopters were investigated; namely, the Bell Jet Ranger, the Sikorsky Black Hawk and the Sikorsky Super Stallion. These rotorcraft have nominal horsepower ratings of 500, 3600, and 13400 respectively. Preliminary results indicated that an all-electric HTS drive system produces an improvement in rotorcraft Takeoff Gross Weight (TOGW) for those rotorcraft with power ratings above 2000 horsepower. The predicted TOGW improvements are up to 9 percent for the medium-sized Sikorsky Black Hawk and up to 20 percent for the large-sized Sikorsky Super Stallion. The small-sized Bell Jet Ranger, however, experienced a penalty in TOGW with the all-electric HTS drive system.

  14. Long-term operating characteristics of Japan's first in-grid HTS power cable

    NASA Astrophysics Data System (ADS)

    Nakano, Tetsutaro; Maruyama, Osamu; Honjo, Shoichi; Watanabe, Michihiko; Masuda, Takato; Hirose, Masayuki; Shimoda, Masahiro; Nakamura, Naoko; Yaguchi, Hiroharu; Machida, Akito

    2015-11-01

    Tokyo Electric Power Company, Sumitomo Electric Industries, Ltd and Mayekawa Mfg. Co., Ltd have jointly conducted the first in-grid demonstration test of a high-temperature superconducting (HTS) cable in Japan, from FY2007 to FY2013. The objective of this project is to evaluate the reliability, stability and other characteristics of the system. The cable structure used in this project is the type of three-in-one cable. As a coolant, sub-cooled liquid nitrogen flows through the gap between the corrugated cryostat and the three cable cores. This structure can realize compactness and reduce heat invasion compared with three single-core HTS cables housed in separate cryostats. The cooling system consists of six refrigerators, two circulation pumps and a reservoir tank. Each refrigerator has a cooling power of 1.0 kW at 77 K, 0.8 kW at 67 K. The number of operating refrigerators is controlled so that the coolant temperature at the cable inlet is kept to preset value. The HTS cable was connected to the live electricity grid from October 29, 2012 to December 25, 2013. In-grid operation continued for more than one year without any accidental interruption of operation or other operating issues. During this time, we studied the operating performance of the HTS cable in dependence on the sub-cooled LN2 temperature.

  15. Performance evolution of 60 kA HTS cable prototypes in the EDIPO test facility

    NASA Astrophysics Data System (ADS)

    Bykovsky, N.; Uglietti, D.; Sedlak, K.; Stepanov, B.; Wesche, R.; Bruzzone, P.

    2016-08-01

    During the first test campaign of the 60 kA HTS cable prototypes in the EDIPO test facility, the feasibility of a novel HTS fusion cable concept proposed at the EPFL Swiss Plasma Center (SPC) was successfully demonstrated. While the measured DC performance of the prototypes at magnetic fields from 8 T to 12 T and for currents from 30 kA to 70 kA was close to the expected one, an initial electromagnetic cycling test (1000 cycles) revealed progressive degradation of the performance in both the SuperPower and SuperOx conductors. Aiming to understand the reasons for the degradation, additional cycling (1000 cycles) and warm up-cool down tests were performed during the second test campaign. I c performance degradation of the SuperOx conductor reached ∼20% after about 2000 cycles, which was reason to continue with a visual inspection of the conductor and further tests at 77 K. AC tests were carried out at 0 and 2 T background fields without transport current and at 10 T/50 kA operating conditions. Results obtained in DC and AC tests of the second test campaign are presented and compared with appropriate data published recently. Concluding the first iteration of the HTS cable development program at SPC, a summary and recommendations for the next activity within the HTS fusion cable project are also reported.

  16. Monitoring of HTS compound library quality via a high-resolution image acquisition and processing instrument.

    PubMed

    Baillargeon, Pierre; Scampavia, Louis; Einsteder, Ross; Hodder, Peter

    2011-06-01

    This report presents the high-resolution image acquisition and processing instrument for compound management applications (HIAPI-CM). The HIAPI-CM combines imaging spectroscopy and machine-vision analysis to perform rapid assessment of high-throughput screening (HTS) compound library quality. It has been customized to detect and classify typical artifacts found in HTS compound library microtiter plates (MTPs). These artifacts include (1) insufficient volume of liquid compound sample, (2) compound precipitation, and (3) colored compounds that interfere with HTS assay detection format readout. The HIAPI-CM is also configured to automatically query and compare its analysis results to data stored in a LIMS or corporate database, aiding in the detection of compound registration errors. To demonstrate its capabilities, several compound plates (n=5760 wells total) containing different artifacts were measured via automated HIAPI-CM analysis, and results compared with those obtained by manual (visual) inspection. In all cases, the instrument demonstrated high fidelity (99.8% empty wells; 100.1% filled wells; 94.4% for partially filled wells; 94.0% for wells containing colored compounds), and in the case of precipitate detection, the HIAPI-CM results significantly exceeded the fidelity of visual observations (220.0%). As described, the HIAPI-CM allows for noninvasive, nondestructive MTP assessment with a diagnostic throughput of about 1min per plate, reducing analytical expenses and improving the quality and stewardship of HTS compound libraries.

  17. Analysis of Iterative Screening with Stepwise Compound Selection Based on Novartis In-house HTS Data.

    PubMed

    Paricharak, Shardul; IJzerman, Adriaan P; Bender, Andreas; Nigsch, Florian

    2016-05-20

    With increased automation and larger compound collections, the development of high-throughput screening (HTS) started replacing previous approaches in drug discovery from around the 1980s onward. However, even today it is not always appropriate, or even feasible, to screen large collections of compounds in a particular assay. Here, we present an efficient method for iterative screening of small subsets of compound libraries. With this method, the retrieval of active compounds is optimized using their structural information and biological activity fingerprints. We validated this approach retrospectively on 34 Novartis in-house HTS assays covering a wide range of assay biology, including cell proliferation, antibacterial activity, gene expression, and phosphorylation. This method was employed to retrieve subsets of compounds for screening, where selected hits from any given round of screening were used as starting points to select chemically and biologically similar compounds for the next iteration. By only screening ∼1% of the full screening collection (∼15 000 compounds), the method consistently retrieves diverse compounds belonging to the top 0.5% of the most active compounds for the HTS campaign. For most of the assays, over half of the compounds selected by the method were found to be among the 5% most active compounds of the corresponding full-deck HTS. In addition, the stringency of the iterative method can be modified depending on the number of compounds one can afford to screen, making it a flexible tool to discover active compounds efficiently. PMID:26878899

  18. Trapped magnetic field measurements on HTS bulk by peak controlled pulsed field magnetization

    NASA Astrophysics Data System (ADS)

    Ida, Tetsuya; Watasaki, Masahiro; Kimura, Yosuke; Miki, Motohiro; Izumi, Mitsuru

    2010-06-01

    For the past several years, we have studied the high-temperature superconducting (HTS) synchronous motor assembled with melt-textured Gd-Ba-Cu-O bulk magnets. If the single pulse field magnetizes a bulk effectively, size of electrical motor will become small for the strong magnetic field of the HTS magnets without reducing output power of motor. In the previous study, we showed that the HTS bulk was magnetized to excellent cone-shape magnetic field distribution by using the waveform control pulse magnetization (WCPM) method. The WCPM technique made possible the active control of the waveform on which magnetic flux motion depended. We generated the pulse waveform with controlled risetime for HTS bulk magnetization to suppress the magnetic flux motion which decreases magnetization efficiency. The pulsed maximum magnetic flux density with slow risetime is not beyond the maximum magnetic flux density which is trapped by the static field magnetization. But, as for applying the pulse which has fast risetime, the magnetic flux which exceed greatly the threshold penetrates the bulk and causes the disorder of the trapped magnetic distribution. This fact suggests the possibility that the threshold at pulsed magnetization influences the dynamic magnetic flux motion. In this study, Gd-Ba-Cu-O bulk is magnetized by the controlled arbitrary trapezoidal shape pulse, of which the maximum magnetic flux density is controlled not to exceed the threshold. We will present the trapped magnetic characteristics and the technique to generate the controlled pulsed field.

  19. Improvement of levitation force characteristics in magnetic levitation type seismic isolation device composed of HTS bulk and permanent magnet

    NASA Astrophysics Data System (ADS)

    Tsuda, M.; Kawasaki, T.; Yagai, T.; Hamajima, T.

    2008-02-01

    Magnetic levitation type seismic isolation device composed of HTS bulks and permanent magnets can theoretically remove horizontal vibration completely. It is, however, not easy to generate the large levitation force by using only the levitation system composed of HTS bulk and permanent magnet (HTS-PM system). We focused on a hybrid levitation system composed of the HTS-PM system and the PM-PM system composed of only permanent magnets and investigated the suitable arranging method of the hybrid system for improving levitation force and obtaining stable levitation. In order to clarify the most suitable permanent magnet arrangement in the PM-PM system for the levitation force improvement, repulsive force between permanent magnets was measured in various kinds of the PM-PM system. The maximum repulsive force per unit area in the PM-PM system was at least three times larger than the levitation force per unit area in the HTS-PM system, so that the levitation force in the hybrid system was larger than that of the HTS-PM system. Stable levitation was also achieved in the hybrid system. This is because repulsive force in the PM-PM system against horizontal displacement was much smaller than restoring force in the HTS-PM system.

  20. Characteristics of trapped magnetic fields in HTS bulk annuli with various axial spaces for compact NMR magnets

    NASA Astrophysics Data System (ADS)

    Kim, S. B.; Imai, M.; Takano, R.; Kashima, K.; Hahn, S.

    2010-11-01

    Recently, the performance of high-temperature superconducting (HTS) bulks such as a critical current density, size, and mechanical strength has been improved. In consequence, various applications with HTS bulks such as motors, bearings, and flywheels are being investigated by many research groups; Compact nuclear magnetic resonance (NMR) magnet is one of the new applications after a technique to enhance maximum trapped field of an HTS bulk more than 11.7 T, 500 MHz 1H NMR frequency, has been developed. This new compact NMR magnet out of HTS bulks is far less expensive than those conventional NMR magnets and expected to be widely used in food and drug industry. In design and manufacture of those compact NMR magnets, the issues of spatial homogeneity and temporal stability of trapped magnetic fields in HTS bulk annuli are very important. In this paper, the characteristics of the trapped magnetic fields in a stack of assembled HTS bulk annuli were investigated with various axial spaces between HTS bulks, experimentally and analytically.

  1. An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

    NASA Technical Reports Server (NTRS)

    Brown, G. V.; Dirusso, E.; Provenza, A. J.

    1995-01-01

    A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

  2. Reflectance characterization of tape-based plasma mirrors

    NASA Astrophysics Data System (ADS)

    Shaw, B. H.; Steinke, S.; van Tilborg, J.; Leemans, W. P.

    2016-06-01

    Specular reflections of relativistic laser pulses from an overdense plasma mirror (PM) were studied experimentally. The pointing stability of the PM and reflectance of the input laser were characterized. The solid material used for the PM was a VHS tape. This study was done for the magnetic and plastic sides of the VHS tape, and for input light of both s and p-polarizations. The laser pulse fluence was varied by changing the focus position relative to the tape surface, which changed the spot size at the tape. The pointing fluctuations of the reflected pulses caused by the PM were ≃1 mrad. A peak reflectance of 82% was obtained from the plastic surface of the VHS tape when focusing s-polarized light 4 mm from the tape surface (the wavefront quality was confirmed to be conserved). An analytic model was developed to understand the physics of the interaction for each tape material and polarization. Fitting of our model parameters to the experimental results allowed an estimate of the key plasma parameters such as plasma expansion velocity, ionization intensity, and fraction of absorbed laser energy.

  3. Unrecorded wideband instrumentation reference tape feasibility study: Frequency response results

    NASA Astrophysics Data System (ADS)

    Hust, D. R.

    1980-03-01

    An investigation was conducted to determine signal response variations when a variety of wideband instrumentation magnetic tapes is used on a cross section of recorder/reproducer systems. Data for the investigation were collected by transmitting a set of eight sample test tapes to participating data recording/reproducing facilities for the purpose of making data measurements. Data collected represent measurements made with 16 different recorder/reproducer systems at 11 different testing facilities located throughout the United States. The data-collection process involved approximately 2 years of testing. The originating/coordinating facility was the Pacific Missile Test Center, Point Mugu, California. The test results indicated the following: all of the sample test tapes exhibited bidirectional performance within the limits of measurement repeatability; overall system stability was better in the low-band regions than in the upper-band regions; and the overall relative frequency response of the sample test tapes did not change appreciably during the 2 year investigative period. The most significant result of the test measurements is that at least 90% of the frequency response values were within + or - 2.0 dB at all frequencies. Machine stability factors such as azimuth, equalizer, and gain changes had more effect on data variability than did magnetic tape or tape speed. The use of a reference tape system is recommended as a method to assure that relative frequency response variations will be less than or equal to + or - 2.0 dB.

  4. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  5. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  6. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  7. Magnetization ac loss reduction in HTS CORC® cables made of striated coated conductors

    NASA Astrophysics Data System (ADS)

    Vojenčiak, M.; Kario, A.; Ringsdorf, B.; Nast, R.; van der Laan, D. C.; Scheiter, J.; Jung, A.; Runtsch, B.; Gömöry, F.; Goldacker, W.

    2015-10-01

    High temperature superconductors (HTSs), like for instance REBCO (RE = rare earth) coated conductors, are of high potential for building large superconducting magnets. Some magnets, such as accelerator magnets, require the use of superconducting cables to allow fast ramping, and low magnetization loss to mitigate field quality issues. One of the methods to lower ac loss is to divide the superconducting layer in the tape into filaments. In this paper, conductors with copper stabilization for practical applications are laser scribed into narrow filaments. Striated tapes are then wound into conductor on round core (CORC®) cables. The critical current and magnetization ac loss of single tapes were measured. We found that the stabilizing copper layer causes difficulties for laser scribing. The degradation of the critical current is more pronounced than in the case of non-stabilized tapes. The selection of the number of filaments is therefore a compromise between critical current degradation and reduction of ac loss. Based on the results obtained from single tape experiments, the optimum number of filaments in 4 mm wide tapes was chosen, and CORC® cables with 2, 3 and 4 layers of tapes with and without filaments were manufactured. Magnetization ac loss measurements at 77 K showed a reduction of ac loss in the cables with filaments. This reduction corresponds almost to the number of filaments. Measurement at different frequencies also showed that the coupling loss in CORC® cables with a short twist-pitch is relatively small in comparison to hysteretic loss.

  8. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  9. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  10. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  11. How to make sticky tapes stickier

    NASA Astrophysics Data System (ADS)

    Ponson, Laurent; Xia, Shuman; Ravichandran, Guruswami; Bhattacharya, Kaushik; California Institute of Technology Team

    2011-03-01

    Thin film adhesives have become increasingly important in various applications such as packaging and coating, and we benefit daily of their adhesion properties by using various kinds of tapes. Despite the apparent simplicity of these systems, a certain number of questions remain open. In particular, important efforts have been deployed recently to understand the effect of the complex tridimensional and highly heterogeneous structure at the interface of some adhesives, such as the one encountered in nature like the geckos toes. Although inspired by these natural adhesives, we studied a much simpler system, and however largely unexplored: a thin film with spatially varying adhesion energy and elastic properties. We will show how these heterogeneities introduced at the microscale can generate quite unexpected macroscopic behaviors, and that one can this way design stronger adhesives with new properties. Beyond their practical interests, these systems involve long range elastic interactions and heterogeneities resulting in a rich and complex physics that will be illustrated through experimental examples and their theoretical interpretation.

  12. 77 FR 61279 - Approval and Promulgation of Implementation Plans; Mississippi; 110(a)(2)(G) Infrastructure...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-09

    ...) Infrastructure Requirement for the 1997 and 2006 Fine Particulate Matter National Ambient Air Quality Standards... ``110(a)(2)(G) Infrastructure Requirement for the 1997 and 2006 Fine Particulate Matter National Ambient... section 110(a)(2)(G), of the CAA for both the 1997 and 2006 fine particulate matter (PM 2.5 )...

  13. WELLTON GOVERNMENT CAMP, PERMANENT GARAGE TYPE 2G. PLAN, ELEVATIONS, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    WELLTON GOVERNMENT CAMP, PERMANENT GARAGE TYPE 2-G. PLAN, ELEVATIONS, AND SECTIONS. Drawing 50-308-4553, dated October 21, 1949. U.S. Department of the Interior, Bureau of Reclamation, Yuma, Arizona - Wellton-Mohawk Irrigation System, Permanent Garage Type 2-G, 30611 and 30621 Wellton-Mohawk Drive, Wellton, Yuma County, AZ

  14. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  15. 11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM FLOOR OF DRYDOCK NO. 5. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA

  16. Creating and Using Video Tapes for Cartographic Demonstrations.

    ERIC Educational Resources Information Center

    Andrews, Sona K.; Gersmehl, Philip J.

    1986-01-01

    Offers nine suggestions for video tape production and instructional use in a student laboratory for a cartography course. Briefly discusses costs and benefits, including more time for instructors to focus on specific techniques and individual questions. (TRS)

  17. STS-34 mission highlights resource tape, part 1

    NASA Astrophysics Data System (ADS)

    1989-11-01

    This video tape contains important visual events including launch Galileo/IUS deployment, onboard crew activities, and landing. Also included is air-to-ground transmission between the crew and Mission Control.

  18. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  19. Identification and characterization of the heme-binding proteins SeShp and SeHtsA of Streptococcus equi subspecies equi

    PubMed Central

    Nygaard, Tyler K; Liu, Mengyao; McClure, Michael J; Lei, Benfang

    2006-01-01

    Background Heme is a preferred iron source of bacterial pathogens. Streptococcus equi subspecies equi is a bacterial pathogen that causes strangles in horses. Whether S. equi has a heme acquisition transporter is unknown. Results An S. equi genome database was blasted with the heme binding proteins Shp and HtsA of Streptococcus pyogenes, and found that S. equi has the homologue of Shp (designated SeShp) and HtsA (designated SeHtsA). Tag-free recombinant SeShp and SeHtsA and 6xHis-tagged SeHtsA (SeHtsAHis) were prepared and characterized. Purified holoSeShp and holoSeHtsA bind Fe(II)-protoporphyrin IX (heme) and Fe(III)-protoporphyrin IX (hemin) in a 1:1 stoichiometry, respectively, and are designated hemoSeShp and hemiSeHtsA. HemiSeShp and hemiSeHtsAHis can be reconstituted from apoSeShp and apoSeHtsAHis and hemin. HemoSeShp is stable in air and can be oxidized to hemiSeShp by ferricyanide. HemiSeHtsA can be reduced into hemoSeHtsA, which autoxidizes readily. HemoSeShp rapidly transfers its heme to apoSeHtsAHis. In addition, hemoSeShp can also transfer its heme to apoHtsA, and hemoShp is able to donate heme to apoSeHtsAHis. Conclusion The primary structures, optical properties, oxidative stability, and in vitro heme transfer reaction of SeShp and SeHtsA are very similar to those of S. pyogenes Shp and HtsA. The data suggest that the putative cell surface protein SeShp and lipoprotein SeHtsA are part of the machinery to acquire heme in S. equi. The results also imply that the structure, function, and functional mechanism of the heme acquisition machinery are conserved in S. equi and S. pyogenes. PMID:17007644

  20. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  1. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  2. Experimental study of the effects of alternating fields on HTS coils according to the winding insulation conditions

    NASA Astrophysics Data System (ADS)

    Hwang, Y. J.; Ahn, M. C.; Lee, T. S.; Lee, W. S.; Ko, T. K.

    2013-08-01

    This paper examines the effects of alternating fields on high-temperature superconducting (HTS) coils according to the winding insulation condition. Alternating fields can occur in synchronous machines (armature reaction, faults) and other devices. In superconducting synchronous machines, alternating fields affect the operational characteristics of the machine and the superconducting field coil. Therefore, a method of reducing the effects of alternating fields is necessary in superconducting synchronous design. In this study, the effects of alternating fields on the HTS field coil according to the winding insulation condition were experimentally evaluated. The experimental results show that HTS coils made using the no-insulation technique can be a solution for reducing the effects of the alternating field. These results are expected to suggest useful data for applications of HTS field coils in superconducting synchronous machines.

  3. An HTS flux pump operated by directly driving a superconductor into flux flow region in the E– J curve

    NASA Astrophysics Data System (ADS)

    Geng, Jianzhao; Coombs, T. A.

    2016-09-01

    High-T c superconducting (HTS) flux pumps are capable of compensating the persistent current decay in HTS magnets without electrical contact. In this paper, following work on a low-T c superconducting self-switching flux pump, we propose a new HTS flux pump by directly driving a high-T c superconductor into the flux flow region in the E– J curve. The flux pump consists of a transformer which has a superconducting secondary winding shorted by an YBCO-coated conductor bridge. A high alternating current with a much higher positive peak value than the negative peak value is induced in the secondary winding. The current always drives the bridge superconductor into the flux flow region only at around its positive peak value, thus resulting in flux pumping. The proposed flux pump is much simpler than existing HTS flux pumps.

  4. Magnetic fields end-face effect investigation of HTS bulk over PMG with 3D-modeling numerical method

    NASA Astrophysics Data System (ADS)

    Qin, Yujie; Lu, Yiyun

    2015-09-01

    In this paper, the magnetic fields end-face effect of high temperature superconducting (HTS) bulk over a permanent magnetic guideway (PMG) is researched with 3D-modeling numerical method. The electromagnetic behavior of the bulk is simulated using finite element method (FEM). The framework is formulated by the magnetic field vector method (H-method). A superconducting levitation system composed of one rectangular HTS bulk and one infinite long PMG is successfully investigated using the proposed method. The simulation results show that for finite geometrical HTS bulk, even the applied magnetic field is only distributed in x-y plane, the magnetic field component Hz which is along the z-axis can be observed interior the HTS bulk.

  5. An HTS flux pump operated by directly driving a superconductor into flux flow region in the E- J curve

    NASA Astrophysics Data System (ADS)

    Geng, Jianzhao; Coombs, T. A.

    2016-09-01

    High-T c superconducting (HTS) flux pumps are capable of compensating the persistent current decay in HTS magnets without electrical contact. In this paper, following work on a low-T c superconducting self-switching flux pump, we propose a new HTS flux pump by directly driving a high-T c superconductor into the flux flow region in the E- J curve. The flux pump consists of a transformer which has a superconducting secondary winding shorted by an YBCO-coated conductor bridge. A high alternating current with a much higher positive peak value than the negative peak value is induced in the secondary winding. The current always drives the bridge superconductor into the flux flow region only at around its positive peak value, thus resulting in flux pumping. The proposed flux pump is much simpler than existing HTS flux pumps.

  6. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  7. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  8. Nickel plating connector ends on tape processed slapper detonator cables

    SciTech Connect

    Bruns, R.J.

    1989-02-28

    A nickel spot plater has been built as an addition to the other reel-to-reel processing equipment in the Tape Process Laboratory at Mound. This plater, like most of the equipment in the Tape Process Laboratory, is a prototype built to meet Mound's product requirements. This Plating System enables Mound to selectively plate specific areas (connector ends) on a flexible printed circuit cable. 6 refs., 11 figs., 1 tab.

  9. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  10. FGGE/SBUV tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/SBUV Level 2C data set consists of 12 9-track data tapes, each of which contains total ozone and ozone profile data for one calendar month grouped in files containing the data in a 6 hour synoptic time block. The data flow and quality checks in the production of this data set are described as well as the format of the data tapes and the accompanying shipping documents.

  11. Progress Toward Demonstrating a High Performance Optical Tape Recording Technology

    NASA Technical Reports Server (NTRS)

    Oakley, W. S.

    1996-01-01

    This paper discusses the technology developments achieved during the first year of a program to develop a high performance digital optical tape recording device using a solid state, diode pumped, frequency doubled green laser source. The goal is to demonstrate, within two years, useful read/write data transfer rates to at least 100 megabytes per second and a user capacity of up to one terabyte per cartridge implemented in a system using a '3480' style mono-reel tape cartridge.

  12. Buffer layers on metal alloy substrates for superconducting tapes

    DOEpatents

    Jia, Quanxi; Foltyn, Stephen R.; Arendt, Paul N.; Groves, James R.

    2004-10-05

    An article including a substrate, at least one intermediate layer upon the surface of the substrate, a layer of an oriented cubic oxide material having a rock-salt-like structure upon the at least one intermediate layer, and a layer of a SrRuO.sub.3 buffer material upon the oriented cubic oxide material layer is provided together with additional layers such as a HTS top-layer of YBCO directly upon the layer of a SrRuO.sub.3 buffer material layer. With a HTS top-layer of YBCO upon at least one layer of the SrRuO.sub.3 buffer material in such an article, J.sub.c 's of up to 1.3.times.10.sup.6 A/cm.sup.2 have been demonstrated with projected I.sub.c 's of over 200 Amperes across a sample 1 cm wide.

  13. The effect of Kinesio Taping on handgrip strength.

    PubMed

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  14. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  15. The effect of Kinesio Taping on handgrip strength

    PubMed Central

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18–30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values. PMID:25931682

  16. Calibration tests on magnetic tape lightning current detectors

    NASA Astrophysics Data System (ADS)

    Crouch, K. E.

    1980-04-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  17. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  18. Simulation of chain of quenches on toroidal HTS-SMES taking account of thermal and electromagnetic characteristics

    NASA Astrophysics Data System (ADS)

    Oga, Y.; Noguchi, S.; Igarashi, H.

    When a temperature rise occurs at a local area inside a coil of toroidal HTS-SMES by any reason, a temperature hotspot which results in a thermal runaway appears at the local area. Subsequently, after appearing the local normal zone in the HTS coil, the transport current of the HTS coil decrease since the resistance of HTS coil appears and the current partially flows into a parallel-connecting shunt resistance. However, if the transport current of the normal-transitioned HTS coil is hardly changed, the temperature on the hotspot would rise more and then the normal zone would spread rapidly. It may cause a serious accident due to high stored energy. Therefore, using the numerical simulation, we have investigated the behaviors of the coil current, the critical current, and the temperature in the superconducting element coils of HTS-SMES. Consequently, the temperature of the superconducting element coils rises up extremely when a large heat is generated at a certain area of one of them by any reason. Moreover, there is a possibility that the shunt resister hardly functions for protection since the coil is burned out due to high inductances and low resistance of the superconducting element coil.

  19. The study on stress-cone based on HTS cable terminal

    NASA Astrophysics Data System (ADS)

    Wu, C. Y.; Fang, J.; Huang, X. H.; Lu, W. J.; Li, D.; Guo, L. J.

    2013-01-01

    Our research aims at improving the performance of 35 kV class stress-cone for HTS cable terminal. Firstly, the equivalent circuit model of a stress-cone is constructed for simulation. The relation between the sag voltage of each layer can be characterized by structural and material parameters, such as the stress-cone’s plate length, plate radius, insulating material thickness and dielectric constant. Secondly, the simulation based on ANSYS is developed for analyzing the electric field of stress cone of HTS cable terminal, by altering the length of step and insulation material parameter of stress cone, we get the voltage of each plate layer, horizontal electric field and vertical electric field, and the influence of stress-cone parameter on stress cone electric field is analyzed.

  20. Effect of corrugated characteristics on the liquid nitrogen temperature field of HTS cable

    NASA Astrophysics Data System (ADS)

    Li, Z. M.; Li, Y. X.; Zhao, Y. Q.; Gao, C.; Qiu, M.; Chen, G. F.; Gong, M. Q.; Wu, J. F.

    2014-01-01

    In the high temperature superconducting (HTS) cable system, liquid nitrogen is usually chosen to be the coolant because of its low saturation temperature and large latent heat of vaporization. Thus, it is very important for superconducting cables that the liquid nitrogen temperature field keeps stable. However, the cryostat is usually made of flexible corrugated pipes and multi-layer insulation materials. The characteristics (e.g. wave pitch and wave depth) of corrugated pipes may have an effect on the heat exchange between cable and liquid nitrogen, even the whole temperature field of liquid nitrogen. In this paper, a two-dimensional model for 30 m long HTS cable has been modified to analyze the effect of corrugated characteristics on the temperature field of liquid nitrogen. The liquid nitrogen temperature difference between the outlet and the inlet of passage gradually increases as the wave pitch of the corrugated tube decreases and the wave depth increases.

  1. Temperature dependence of levitation force and its relaxation in a HTS levitation system

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Zhang, Xing-Yi; Zhou, You-He

    2010-03-01

    Using a modified Gifford-McMahon refrigerator to cool the cylindrical bulk YBaCuO superconductor within the region of 100-10 K, and using an updated high-temperature superconductor (HTS) maglev measurement system, the levitation force and its time relaxation at different temperatures between a YBaCuO bulk superconductor and a permanent magnet (PM) have been measured under zero-field cooling. It is found that decrease the cooling temperature of HTS can decrease the hysteresis of magnetization and increase the maximum levitation force of each hysteresis loop. For the relaxation of levitation force, if the temperature is continually lowered to 10 K after the relaxation measurement at given cooling temperature is performed for 600 s, the levitation force will continue to decrease sharply with the lowering of temperature even though it will get stable if the temperature is not lowered. Our results shown in this work are a benefit to the understanding of levitation systems.

  2. Influence of Off-Centre Operation on the Performance of HTS Maglev

    NASA Astrophysics Data System (ADS)

    Gou, Y.; He, D.; Zheng, J.; Ye, C.; Xu, Y.; Sun, R.; Che, T.; Deng, Z.

    2014-03-01

    Owing to instinctive self-stable levitation characteristics, high-temperature superconducting (HTS) maglev using bulk high-temperature superconductors attracts more and more attention from scientists and engineers around the world. In this paper, the levitation force relaxation and guidance force characteristics of a Y-Ba-Cu-O levitation unit with different eccentric distances (EDs) off the center of the permanent magnet guideway were experimentally investigated under field-cooling (FC) conditions. Experimental results indicate that the levitation force slightly increases at small EDs firstly, but degrades with further increasing of EDs. However, the maximum guidance force and its stiffness exhibit enhancement in moderate ED range. The results demonstrate that a properly designed initial FC eccentric distance is important for the practical applications of HTS maglev according to specific requirements like running in curve lines.

  3. Stability test of conduction-cooled LTS/HTS composite coil

    NASA Astrophysics Data System (ADS)

    Cui, Ying Min; Wang, Yin Shun; Lv, Gang; Pi, Wei

    2016-06-01

    A small LTS/HTS composite coil made of NbTi/Cu and YBCO, with an inner diameter of 80 mm, an outer diameter of 88mm, a height of 50 mm, and an inductance of 5.5 μH, was designed to test its heat disturbance performance in a GM cryocooler. For comparison, a conventional LTS coil of a similar size made of NbTi/Cu wire was also tested. Transport current was applied from 50 A to 700 A at 8 K and 8.5 K, respectively. The two coils’ heat disturbance, minimum quench energy and quench propagation velocity performance were investigated and simulated. The results indicate that the LTS/HTS composite coil shows better thermal stability and is more fit for operation in conductive cryocooler systems compared to LTS coils.

  4. A method to enhance the curve negotiation performance of HTS Maglev

    NASA Astrophysics Data System (ADS)

    Che, T.; Gou, Y. F.; Deng, Z. G.; Zheng, J.; Zheng, B. T.; Chen, P.

    2015-09-01

    High temperature superconducting (HTS) Maglev has attracted more and more attention due to its special self-stable characteristic, and much work has been done to achieve its actual application, but the research about the curve negotiation is not systematic and comprehensive. In this paper, we focused on the change of the lateral displacements of the Maglev vehicle when going through curves under different velocities, and studied the change of the electromagnetic forces through experimental methods. Experimental results show that setting an appropriate initial eccentric distance (ED), which is the distance between the center of the bulk unit and the center of the permanent magnet guideway (PMG), when cooling the bulks is favorable for the Maglev system’s curve negotiation. This work will provide some available suggestions for improving the curve negotiation performance of the HTS Maglev system.

  5. Cryogen-free lkA-class Ic measurement system featuring an 8 T HTS magnet

    NASA Astrophysics Data System (ADS)

    Strickland, N. M.; Hoffmann, C.; Wimbush, S. C.; Pooke, D. M.; Huang, T.; Lazic, Z.; Chamritski, V.; Talantsev, E. F.; Long, N. J.; Tallon, J. L.

    2014-05-01

    We have developed a cryogen-free critical-current (Ic) measuring system comprising a conduction-cooled 8 T HTS magnet and convection-cooled sample, both cooled by commercial cryocoolers. The sample can be rotated and transport currents of up to 800 A delivered with less than 0.5 K temperature rise during the Ic measurement. The system is automated with respect to variations in temperature (30-90 K), field (0-8 T), and field angle (0-360°). We have used this system to measure HTS wire samples, concentrating on metal-organic deposited YBCO on RABiTS substrates. Particular emphasis is given to the evolution of Ic anisotropy with temperature, and the dangers of extrapolating from 77 K to 30 K.

  6. A cryogen-free HTS Josephson junction detector for terahertz imaging

    NASA Astrophysics Data System (ADS)

    Du, J.; Smart, K.; Li, L.; Leslie, K. E.; Hanham, S. M.; Wang, D. H. C.; Foley, C. P.; Ji, F.; Li, X. D.; Zeng, D. Z.

    2015-08-01

    A cryogen-free terahertz (THz) imaging system based on a high-temperature superconducting (HTS) Josephson junction detector is reported. The detector was made of a YBa2Cu3O7-x step-edge Josephson junction and integrated into an on-chip thin-film antenna. The HTS Josephson detector was cooled via a commercial mechanical cryocooler; an important step towards cryogen-free THz instrumentation, which is critical for industrial acceptance. In addition, it is shown that operating the detector in a cryocooler provides improved flexibility for optimizing the detector parameters and performance due to the ability to adjust the temperature compared to liquid nitrogen cooling methods. The dc and ac characteristics, the detector responsivity and the noise-equivalent power of the detector, and resulting image quality were studied as the function of operating temperatures.

  7. HTS by NMR of Combinatorial Libraries: A Fragment-Based Approach to Ligand Discovery

    PubMed Central

    Wu, Bainan; Zhang, Ziming; Noberini, Roberta; Barile, Elisa; Giulianotti, Marc; Pinilla, Clemencia; Houghten, Richard A.; Pasquale, Elena B.; Pellecchia, Maurizio

    2014-01-01

    SUMMARY Fragment-based ligand design (FBLD) approaches have become more widely used in drug discovery projects from both academia and industry, and are even often preferred to traditional high-throughput screening (HTS) of large collection of compounds (>105). A key advantage of FBLD approaches is that these often rely on robust biophysical methods such as NMR spectroscopy for detection of ligand binding, hence are less prone to artifacts that too often plague the results from HTS campaigns. In this article, we introduce a screening strategy that takes advantage of both the robustness of protein NMR spectroscopy as the detection method, and the basic principles of combinatorial chemistry to enable the screening of large libraries of fragments (>105 compounds) preassembled on a common backbone. We used the method to identify compounds that target protein-protein interactions. PMID:23352136

  8. Evaluation of the invasion heat for the HTS current lead using YBCO

    NASA Astrophysics Data System (ADS)

    Endoh, R.; Kato, H.; Izumi, T.; Shiohara, Y.

    2003-10-01

    Current leads using high- TC superconductors (HTS current leads) are one of cryogenic key devices to assemble compact superconducting magnets such as applied for maglev trains etc. It is essential to evaluate effective thermal conductance through a HTS current lead package together with evaluating Joule heat and critical current for efficient design that has high current capacity and low heat invasion. We have designed the 500 A class HTS current lead package using a YBCO rod whose size is ∅ 3 × 30 mm, and developed an apparatus to measure its heat invasion. Temperature drop as a function of heat flow between the two ends of the package was measured by a conventional steady heat flow method. The quantity of heat invasion of the package under typical practical conditions, from 80 K hot end to 20 K cold end, was 163 mW. This value was simulated to the total value of 158 mW by counting contributions of all the component materials.

  9. Passive radiative cooling of a HTS coil for attitude orbit control in micro-spacecraft

    NASA Astrophysics Data System (ADS)

    Inamori, Takaya; Ozaki, Naoya; Saisutjarit, Phongsatorn; Ohsaki, Hiroyuki

    2015-02-01

    This paper proposes a novel radiative cooling system for a high temperature superconducting (HTS) coil for an attitude orbit control system in nano- and micro-spacecraft missions. These days, nano-spacecraft (1-10 kg) and micro-spacecraft (10-100 kg) provide space access to a broader range of spacecraft developers and attract interest as space development applications. In planetary and high earth orbits, most previous standard-size spacecraft used thrusters for their attitude and orbit control, which are not available for nano- and micro-spacecraft missions because of the strict power consumption, space, and weight constraints. This paper considers orbit and attitude control methods that use a superconducting coil, which interacts with on-orbit space plasmas and creates a propulsion force. Because these spacecraft cannot use an active cooling system for the superconducting coil because of their mass and power consumption constraints, this paper proposes the utilization of a passive radiative cooling system, in which the superconducting coil is thermally connected to the 3 K cosmic background radiation of deep space, insulated from the heat generation using magnetic holders, and shielded from the sun. With this proposed cooling system, the HTS coil is cooled to 60 K in interplanetary orbits. Because the system does not use refrigerators for its cooling system, the spacecraft can achieve an HTS coil with low power consumption, small mass, and low cost.

  10. Cryogenic and Electrical Test Results of 30 M Hts Power Cable

    NASA Astrophysics Data System (ADS)

    Sytnikov, V. E.; Vysotsky, V. S.; Fetisov, S. S.; Nosov, A. A.; Shakaryan, Yu. G.; Kochkin, V. I.; Kiselev, A. N.; Terentyev, Yu. A.; Patrikeev, V. M.; Zubko, V. V.

    2010-04-01

    In the framework of the Russian R&D Program for HTS power devices, 3×30 m cable with operating current of ˜1.5-2 kA and operating voltage of 20 kV was delivered by Russian Scientific R&D Cable Institute as the first stage of the HTS power cables project. Different basic HTS materials, cryostats and current leads were used for the cable design in this essentially research part of the project. The cable is being tested at special test facility for superconducting power devices developed at the R&D Center for Power Engineering. The cryogenic system for the test facility was provided by Stirling. The basic cryogenic system was equipped with a specially developed flow distribution unit. This unit permits variation and control of liquid nitrogen flows, pressures and temperatures in all three cable phases. Dependencies on temperature of critical currents of each phase were measured during cable tests. The results of the project]s first stage were used to develop and produce a 3×200 m cable system for Moscow distribution grid. In the paper results of cryogenic system tests and cable electrical tests are presented.

  11. Design and development of 500 m long HTS cable system in the KEPCO power grid, Korea

    NASA Astrophysics Data System (ADS)

    Sohn, S. H.; Lim, J. H.; Yang, B. M.; Lee, S. K.; Jang, H. M.; Kim, Y. H.; Yang, H. S.; Kim, D. L.; Kim, H. R.; Yim, S. W.; Won, Y. J.; Hwang, S. D.

    2010-11-01

    In Korea, two long-term field demonstrations for high temperature superconducting (HTS) cable have been carried out for several years; Korea Electric Power Corporation (KEPCO) and LS Cable Ltd. (LSC) independently. Encouraged at the result of the projects performed in parallel, a new project targeting the real grid operation was launched in the fourth quarter of 2008 with the Korean government’s financial support. KEPCO and LSC are jointly collaborating in the selection of substation, determination of cable specification, design of cryogenic system, and the scheme of protection coordination. A three phase 500 m long HTS cable at a distribution level voltage of 22.9 kV is to be built at 154/22.9 kV Icheon substation located in near Seoul. A hybrid cryogenic system reflecting the contingency plan is being designed including cryocoolers. The HTS cable system will be installed in the second quarter of 2010, being commissioned by the fall of 2010. This paper describes the objectives of the project and design issues of the cable and cryogenic system in detail.

  12. [Treating anisometric amblyopia with HTS Amblyopia iNet Software--preliminary results].

    PubMed

    Avram, Elena; Stănilă, Adriana

    2013-01-01

    Amblyopia or "lazy eye" represents a disorder of the visual system characterized by poor vision in an eye that is otherwise physically normal. Anisometropia, the condition in which the two eyes have an unequal refractive error, is considered the second most common cause of amblyopia. The purpose of this study is to determine the efficiency of HTS Amblyopia iNet Software by studying the progress of visual acuity, contrast sensitivity and stereopsis vision in anisometropic amblyopic children. 5 patients (age: 5-13 years), treated with HTS Amblyopia iNet Software at OftaTotal Clinic from Sibiu, between 2010-2013, participated in this clinical trial. Initially, visual acuity ranged from 0.25 to 0.8, contrast sensitivity from 1.35 to 1.65 Log. Unit. and 1 patient presented stereoscopic vision. After treatment, visual acuity ranged from 0.8 to 1, contrast sensitivity from 1.35 to 1.95 Log. Unit., also all patients presented stereoscopic vision. HTS Amblyopia iNet Software represents an effective modern approach in the treatment of anisometropic amblyopia.

  13. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  14. Accelerated aging studies and environmental stability of prototype tamper tapes

    SciTech Connect

    Wright, B.W.; Wright, C.W.; Bunk, A.R.

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  15. Kinesio Tape and Shoulder-Joint Position Sense

    PubMed Central

    Aarseth, Lindsay M.; Suprak, David N.; Chalmers, Gordon R.; Lyon, Lonnie; Dahlquist, Dylan T.

    2015-01-01

    Context Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. Objective To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Intervention(s) Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. Main Outcome Measure(s) We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Results Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω2 = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω2 = .002), position (ω2 = .072), and tape by position (ω2 = .027). Conclusions At 90° of elevation, shoulder JPS was impaired by the application of KT. PMID:26090707

  16. 19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. INTERIOR, 'CHILLER NO. 2' (G.S.A. PHOTOCOPY, N.D.) (4 x 5 NEGATIVE) - U.S. General Services Administration, Central Heating Plant, C & D Streets between Twelfth & Thirteenth Streets Southwest, Washington, District of Columbia, DC

  17. The NT digital micro tape recorder

    NASA Astrophysics Data System (ADS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  18. Encouraging vehicle-to-grid (V2G) participation through premium tariff rates

    NASA Astrophysics Data System (ADS)

    Richardson, David B.

    2013-12-01

    The provision of vehicle-to-grid (V2G) services to an electric grid by electric vehicles (EVs) can potentially reduce the cost of vehicle ownership through revenue generation. Recent studies indicate that yearly vehicle profit from V2G may not be sufficient to induce widespread participation. This paper investigates the feasibility of a premium tariff rate for V2G power, similar to current feed-in-tariff (FIT) programs for renewable energy. Using Ontario, Canada as a case study, an hourly time-series model for a fleet of commuter EVs is created. Tariff rates for V2G peak power are calculated based on the same return on investment as the current FIT for renewable energy in Ontario. The tariff rates are competitive with the renewable energy tariffs, especially when EVs are allowed to provide ancillary services to the grid in addition to peak power. Despite the guaranteed rate of return, yearly vehicle profit is low. Two variations are considered to increase vehicle profit, thereby enhancing the attractiveness of V2G. A higher return on investment is favored over direct benefits offered to EV owners. A higher return on investment may be justifiable based on the higher level of risk inherent in V2G when compared to renewable energy.

  19. The HABP2 G534E polymorphism does not increase nonmedullary thyroid cancer risk in Hispanics

    PubMed Central

    Bohórquez, Mabel E; Estrada, Ana P; Stultz, Jacob; Sahasrabudhe, Ruta; Williamson, John; Lott, Paul; Duque, Carlos S; Donado, Jorge; Mateus, Gilbert; Bolaños, Fernando; Vélez, Alejandro; Echeverry, Magdalena

    2016-01-01

    Familial nonmedullary thyroid cancer (NMTC) has not been clearly linked to causal germline variants, despite the large role that genetic factors play in risk. Recently, HABP2 G534E (rs7080536A) has been implicated as a causal variant in NMTC. We have previously shown that the HABP2 G534E variant is not associated with TC risk in patients from the British Isles. Hispanics are the largest and the youngest minority in the United States and NMTC is now the second most common malignancy in women from this population. In order to determine if the HABP2 G534E variant played a role in NMTC risk among Hispanic populations, we analyzed 281 cases and 1105 population-matched controls from a multicenter study in Colombia, evaluating the association through logistic regression. We found that the HABP2 G534E variant was not significantly associated with NMTC risk (P=0.843) in this Hispanic group. We also stratified available clinical data by multiple available clinicopathological variables and further analyzed the effect of HABP2 on NMTC presentation. However, we failed to detect associations between HABP2 G534E and NMTC risk, regardless of disease presentation (P≥0.273 for all cases). Therefore, without any significant associations between the HABP2 G534E variant and NMTC risk, we conclude that the variant is not causal of NMTC in this Hispanic population. PMID:27097599

  20. The HABP2 G534E polymorphism does not increase nonmedullary thyroid cancer risk in Hispanics.

    PubMed

    Bohórquez, Mabel E; Estrada, Ana P; Stultz, Jacob; Sahasrabudhe, Ruta; Williamson, John; Lott, Paul; Duque, Carlos S; Donado, Jorge; Mateus, Gilbert; Bolaños, Fernando; Vélez, Alejandro; Echeverry, Magdalena; Carvajal-Carmona, Luis G

    2016-05-01

    Familial nonmedullary thyroid cancer (NMTC) has not been clearly linked to causal germline variants, despite the large role that genetic factors play in risk. Recently, HABP2 G534E (rs7080536A) has been implicated as a causal variant in NMTC. We have previously shown that the HABP2 G534E variant is not associated with TC risk in patients from the British Isles. Hispanics are the largest and the youngest minority in the United States and NMTC is now the second most common malignancy in women from this population. In order to determine if the HABP2 G534E variant played a role in NMTC risk among Hispanic populations, we analyzed 281 cases and 1105 population-matched controls from a multicenter study in Colombia, evaluating the association through logistic regression. We found that the HABP2 G534E variant was not significantly associated with NMTC risk (P=0.843) in this Hispanic group. We also stratified available clinical data by multiple available clinicopathological variables and further analyzed the effect of HABP2 on NMTC presentation. However, we failed to detect associations between HABP2 G534E and NMTC risk, regardless of disease presentation (P≥0.273 for all cases). Therefore, without any significant associations between the HABP2 G534E variant and NMTC risk, we conclude that the variant is not causal of NMTC in this Hispanic population. PMID:27097599

  1. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  2. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  3. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  4. Kinesiology tape does not facilitate muscle performance: A deceptive controlled trial.

    PubMed

    Poon, K Y; Li, S M; Roper, M G; Wong, M K M; Wong, O; Cheung, R T H

    2015-02-01

    Kinesiology tape (KinTape) is a therapeutic tape without much understanding of its mechanism. KinTape claims to increase cutaneous stimulation, which facilitates motor unit firing, and consequently improves functional performance; however these, benefits could be due to placebo effects. This study investigated the true effects of KinTape by a deceptive, randomized, and controlled trial. Thirty healthy participants performed isokinetic testing of three taping conditions: true facilitative KinTape, sham KinTape, and no KinTape. The participants were blindfolded during the evaluation. Under the pretense of applying adhesive muscle sensors, KinTape was applied to their quadriceps in the first two conditions. Normalized peak torque, normalized total work, and time to peak torque were measured at two angular speeds (60°/s and 180°/s) and analyzed with one-way repeated measures ANOVA. Participants were successfully deceived and they were ignorant about KinTape. No significant differences were found between normalized peak torque, normalized total work, and time to peak torque at 60°/s or 180°/s (p = 0.31-0.99) between three taping conditions. The results showed that KinTape did not facilitate muscle performance in generating higher peak torque, yielding a greater total work, or inducing an earlier onset of peak torque. These findings suggest that previously reported muscle facilitatory effects using KinTape may be attributed to placebo effects.

  5. Syndrome to gene (S2G): in-silico identification of candidate genes for human diseases.

    PubMed

    Gefen, Avitan; Cohen, Raphael; Birk, Ohad S

    2010-03-01

    The identification of genomic loci associated with human genetic syndromes has been significantly facilitated through the generation of high density SNP arrays. However, optimal selection of candidate genes from within such loci is still a tedious labor-intensive bottleneck. Syndrome to Gene (S2G) is based on novel algorithms which allow an efficient search for candidate genes in a genomic locus, using known genes whose defects cause phenotypically similar syndromes. S2G (http://fohs.bgu.ac.il/s2g/index.html) includes two components: a phenotype Online Mendelian Inheritance in Man (OMIM)-based search engine that alleviates many of the problems in the existing OMIM search engine (negation phrases, overlapping terms, etc.). The second component is a gene prioritizing engine that uses a novel algorithm to integrate information from 18 databases. When the detailed phenotype of a syndrome is inserted to the web-based software, S2G offers a complete improved search of the OMIM database for similar syndromes. The software then prioritizes a list of genes from within a genomic locus, based on their association with genes whose defects are known to underlie similar clinical syndromes. We demonstrate that in all 30 cases of novel disease genes identified in the past year, the disease gene was within the top 20% of candidate genes predicted by S2G, and in most cases--within the top 10%. Thus, S2G provides clinicians with an efficient tool for diagnosis and researchers with a candidate gene prediction tool based on phenotypic data and a wide range of gene data resources. S2G can also serve in studies of polygenic diseases, and in finding interacting molecules for any gene of choice.

  6. A New Tracking Method for Helical Scanning Optical Tape Recorder

    NASA Astrophysics Data System (ADS)

    Narahara, Tatsuya; Kamatani, Yoshiteru; Nakao, Takashi; Kumai, Satoshi; Ozue, Tadashi

    1993-11-01

    Using a new tracking method, high track density recording on an optical tape has been achieved with a helical-scanning optical tape recorder (HS-OTR). In this recorder, the tape is wrapped around a drum, which has a high numerical-aperture objective lens of 0.50, without contact with the rotating part by means of air pressure. In the optical design, moving parts, both focus and tracking actuators, light source and reproducing optics are placed outside the rotary drum. With this system, a high carrier-to-noise-ratio of 51 dB for 1 μm mark length has been achieved. Using the tracking method, which includes a starting point servo loop, written marks have been reproduced track by track with a 2 μm pitch.

  7. Experimental Investigations of Woven Textile Tape as Strain Sensor

    NASA Astrophysics Data System (ADS)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  8. Critical Current Measurements in Commercial Tapes, Coils, and Magnets.

    NASA Astrophysics Data System (ADS)

    Gubser, D. U.; Soulen, R. J., Jr.; Fuller-Mora, W. W.; Francavilla, T. L.

    1996-03-01

    We have measured a number of tapes, coils, and magnets produced by commercial vendors and determined their properties as functions of magnetic field and temperature. The tapes were measured at the National High Magnetic Field Laboratory in magnetic fields to 20 tesla and at temperatures of 4.2 K, 27 K, 65 K, and 77 K. For the tapes we report critical currents and current-voltage characteristics. Six inch diameter coils were measured at NRL in zero magnetic field. Critical currents, current-voltage characteristics, and reliability studies are reported for the coils. Larger 10 inch diameter coils, which are to be used in a 200 hp superconducting motor, were also measured and results will be presented. The talk will also review the status of the most recent tests of the superconducting motor.

  9. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha; Matias, Vladimir; Arendt, Paul N.; Foltyn, Stephen R.; Bronisz, Lawrence E.

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  10. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  11. Mirror-touch and ticker tape experiences in synesthesia.

    PubMed

    Chun, Charlotte A; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2-4%) and sequence-space synesthesia (9-14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes.

  12. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  13. Loss of PLA2G6 leads to elevated mitochondrial lipid peroxidation and mitochondrial dysfunction

    PubMed Central

    Castillo-Quan, Jorge Iván; Bartolome, Fernando; Angelova, Plamena R.; Li, Li; Pope, Simon; Cochemé, Helena M.; Khan, Shabana; Asghari, Shabnam; Bhatia, Kailash P.; Hardy, John; Abramov, Andrey Y.; Partridge, Linda

    2015-01-01

    The PLA2G6 gene encodes a group VIA calcium-independent phospholipase A2 beta enzyme that selectively hydrolyses glycerophospholipids to release free fatty acids. Mutations in PLA2G6 have been associated with disorders such as infantile neuroaxonal dystrophy, neurodegeneration with brain iron accumulation type II and Karak syndrome. More recently, PLA2G6 was identified as the causative gene in a subgroup of patients with autosomal recessive early-onset dystonia-parkinsonism. Neuropathological examination revealed widespread Lewy body pathology and the accumulation of hyperphosphorylated tau, supporting a link between PLA2G6 mutations and parkinsonian disorders. Here we show that knockout of the Drosophila homologue of the PLA2G6 gene, iPLA2-VIA, results in reduced survival, locomotor deficits and organismal hypersensitivity to oxidative stress. Furthermore, we demonstrate that loss of iPLA2-VIA function leads to a number of mitochondrial abnormalities, including mitochondrial respiratory chain dysfunction, reduced ATP synthesis and abnormal mitochondrial morphology. Moreover, we show that loss of iPLA2-VIA is strongly associated with increased lipid peroxidation levels. We confirmed our findings using cultured fibroblasts taken from two patients with mutations in the PLA2G6 gene. Similar abnormalities were seen including elevated mitochondrial lipid peroxidation and mitochondrial membrane defects, as well as raised levels of cytoplasmic and mitochondrial reactive oxygen species. Finally, we demonstrated that deuterated polyunsaturated fatty acids, which inhibit lipid peroxidation, were able to partially rescue the locomotor abnormalities seen in aged flies lacking iPLA2-VIA gene function, and restore mitochondrial membrane potential in fibroblasts from patients with PLA2G6 mutations. Taken together, our findings demonstrate that loss of normal PLA2G6 gene activity leads to lipid peroxidation, mitochondrial dysfunction and subsequent mitochondrial membrane

  14. Identification of Aquifex aeolicus tRNA (m2(2G26) methyltransferase gene.

    PubMed

    Takeda, Hiroshi; Hori, Hiroyuki; Endo, Yaeta

    2002-01-01

    The modifications of N2,N2-dimethylguanine (m2(2)G) are found in tRNAs and rRNAs from eukarya and archaea. In tRNAs, modification at position G26 is generated by tRNA (m2(2)G26) methyltransferase, which is encoded by the corresponding gene, trm1. This enzyme catalyzes the methyl-transfer from S-adenosyl-L-methionine to the semi-conserved residue, G26, via the intermediate modified base, m2G26. Recent genome sequencing project has been reported that the putative trm1 is encoded in the genome of Aquifex aeolicus, a hyper-thermophilic eubacterium as only one exception among eubacteria. In order to confirm whether this bacterial trm1 gene product is a real tRNA (m2(2)G26) methyltransferase or not, we expressed this protein by wheat germ in vitro cell-free translation system. Our biochemical analysis clearly showed that this gene product possessed tRNA (m2(2)G26) methyltransferase activity.

  15. Graphite composite tape in beam-pumped oil wells

    SciTech Connect

    Hensley, H.N.; Tanner, C.J.

    1984-09-01

    A continuous, reelable graphite composite tape is being developed as an alternative to jointed sucker rods for use in beam pumped oil wells. Four units have been tested in wells. The composite tape is composed of graphite fibers, glass fabric, Kevlar fibers and vinylester resin. Graphite fibers have a high modulus of elasticity and provide the longitudinal stiffness needed to operate the downhole pump, while allowing a thin cross section flexible enough to be wound onto small diameter reels. This advanced graphite composite is the first practical, lightweight, reelable alternative to jointed sucker rods.

  16. The new CERN tape software - getting ready for total performance

    NASA Astrophysics Data System (ADS)

    Cano, E.; Murray, S.; Kruse, D. F.; Kotlyar, V.; Côme, D.

    2015-12-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  17. USING A TAPED INTERVENTION TO IMPROVE KINDERGARTEN STUDENTS' NUMBER IDENTIFICATION

    PubMed Central

    Krohn, Katherine R; Skinner, Christopher H; Fuller, Emily J; Greear, Corrine

    2012-01-01

    A multiple baseline design across students was used to evaluate the effects of a taped numbers (TN) intervention on the number-identification accuracy of 4 kindergarten students. During TN, students attempted to name the numbers 0 through 9 on randomized lists before each number was provided via a tape player 2 s later. All 4 students showed immediate increases and reached 100% in number-identification accuracy. One student reached 100% accuracy after TN was supplemented with performance feedback, reinforcement, and overcorrection. PMID:22844152

  18. Raman identification of drug of abuse particles collected with colored and transparent tapes.

    PubMed

    Moreno, Victor Molina; López-López, María; Atoche, Juan-Carlos; García-Ruiz, Carmen

    2014-03-01

    Raman microscopy is a useful tool for the analysis of drug particles collected with adhesive tapes. In this work, first, the spectra of thirty drugs of abuse, degradation products, metabolites, and common cutting agent standards were recorded and the Raman bands observed were summarized providing the forensic analyst useful information for the identification of drug evidence. Then, the collection of different drug particles by a fingerprint lifting tape commonly used to remove and store fingerprints and fibers, and a white and green packaging tape, followed by the subsequent identification of the drugs by confocal Raman spectroscopy was performed. The particles were analyzed on top of the tapes, trapped between glass slides and the tapes, trapped in the tape folded over itself in the case of the transparent tape, and after folding and unfolding the tape in the case of the colored tape. The results obtained by the different approaches show that both tapes did not compromise the drugs spectra. However, the use of transparent tape is preferred because this tape allows the previous visual detection of the particles. Finally, several drug and sugar particles were spread over a clean table and inside a pocket, and the particles were collected with transparent tape and then properly identified. Although good results were obtained in both cases, the amount of fibers and other substances present in the collection area made the previous detection of the particles difficult and increases the analysis time. PMID:24630328

  19. Raman identification of drug of abuse particles collected with colored and transparent tapes.

    PubMed

    Moreno, Victor Molina; López-López, María; Atoche, Juan-Carlos; García-Ruiz, Carmen

    2014-03-01

    Raman microscopy is a useful tool for the analysis of drug particles collected with adhesive tapes. In this work, first, the spectra of thirty drugs of abuse, degradation products, metabolites, and common cutting agent standards were recorded and the Raman bands observed were summarized providing the forensic analyst useful information for the identification of drug evidence. Then, the collection of different drug particles by a fingerprint lifting tape commonly used to remove and store fingerprints and fibers, and a white and green packaging tape, followed by the subsequent identification of the drugs by confocal Raman spectroscopy was performed. The particles were analyzed on top of the tapes, trapped between glass slides and the tapes, trapped in the tape folded over itself in the case of the transparent tape, and after folding and unfolding the tape in the case of the colored tape. The results obtained by the different approaches show that both tapes did not compromise the drugs spectra. However, the use of transparent tape is preferred because this tape allows the previous visual detection of the particles. Finally, several drug and sugar particles were spread over a clean table and inside a pocket, and the particles were collected with transparent tape and then properly identified. Although good results were obtained in both cases, the amount of fibers and other substances present in the collection area made the previous detection of the particles difficult and increases the analysis time.

  20. Distribution of AC loss in a HTS magnet for SMES with different operating conditions

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Tang, Y.; Ren, L.; Jiao, F.; Song, M.; Cao, K.; Wang, D.; Wang, L.; Dong, H.

    2013-11-01

    The AC loss induced in superconducting tape may affect the performance of a superconducting device applied to power system, such as transformer, cable, motor and even Superconducting Magnetic Energy Storage (SMES). The operating condition of SMES is changeable due to the need of compensation to the active or reactive power according to the demand of a power grid. In this paper, it is investigated that the distribution of AC loss for a storage magnet on different operating conditions, which is based on finite element method (FEM) and measured properties of BSCCO/Ag tapes. This analytical method can be used to optimize the SMES magnet.

  1. THE VITAMIN B(1) AND B(2) G CONTENT OF LIVER EXTRACT AND BREWERS' YEAST CONCENTRATE.

    PubMed

    Miller, D K; Rhoads, C P

    1934-02-28

    1. Liver extract powder, No. 343 Lilly, and the same material prepared for parenteral use, when administered daily by mouth in amounts derived from 2.5 gm. of fresh whole liver, to rats weighing from 40 to 50 gm., contain sufficient vitamin B(1) to support normal growth, provided the animals receive in addition an adequate amount of vitamin B(2) G. Moreover, liver extract in the forms mentioned, administered in the same amounts, does not contain sufficient vitamin B(2) G to maintain normal growth of similar rate when all other necessary constituents of the diet are provided. 2. Liver extract (Lilly) in the form prepared for parenteral use, when administered daily by intraperitoneal injections, in amounts derived from 2.5 gm. of fresh whole liver, to rats under standard experimental conditions, does not contain sufficient vitamin B(2) G to maintain normal growth. Furthermore, the amount of vitamin B(1) present in liver extract in this form is not as effective in supporting normal growth when given by intraperitoneal injection as it is when given by mouth. 3. Vegex, when administered daily in amounts of 50, 150, and 250 mg. to rats of 40 to 50 gm. in weight contains sufficient vitamin B(1) to maintain normal growth of the rats, provided the animals receive in addition an adequate amount of vitamin B(2) G. However, vegex in the same amounts does not contain sufficient vitamin B(2) G to support normal growth of similar rats when all other necessary constituents of the diet are provided. 4. These experiments indicate that the extrinsic, anti-anemic factor of Castle and the thermostable growth-promoting food constituent, commonly known as vitamin B(2) G, are not identical.

  2. Cryogenic experiences during W7-X HTS-current lead tests

    SciTech Connect

    Richter, Thomas; Lietzow, Ralph

    2014-01-29

    The Karlsruhe Institute of Technology (KIT) was responsible for design, production and test of the High Temperature Superconductor (HTS) current leads (CL) for the stellerator Wendelstein 7-X (W7-X). 16 current leads were delivered. Detailed prototype tests as well as the final acceptance tests were performed at KIT, using a dedicated test cryostat assembled beside and connected to the main vacuum vessel of the TOSKA facility. A unique feature is the upside down orientation of the current leads due to the location of the power supplies in the basement of the experimental area of W7-X. The HTS-CL consists of three main parts: the cold end for the connection to the bus bar at 4.5 K, the HTS part operating in the temperature range from 4.5 K to 65 K and a copper heat exchanger (HEX) in the temperature range from 65 K to room temperature, which is cooled with 50 K helium. Therefore in TOSKA it is possible to cool test specimens simultaneously with helium at two different temperature levels. The current lead tests included different scenarios with currents up to 18.2 kA. In total, 10 cryogenic test campaigns with a total time of about 24 weeks were performed till beginning of 2013. The test facility as well as the 2 kW cryogenic plant of ITEP showed a very good reliability. However, during such a long and complex experimental campaign, one has to deal with failures, technical difficulties and incidents. The paper gives a summary of the test performance comprising the test preparation and operation. This includes the performance and reliability of the refrigerator and the test facility with reference to the process measuring and control system, the data acquisition system, as well as the building infrastructure.

  3. Evaluation of micro-parallel liquid chromatography as a method for HTS-coupled actives verification.

    PubMed

    Simeonov, Anton; Yasgar, Adam; Klumpp, Carleen; Zheng, Wei; Shafqat, Naeem; Oppermann, Udo; Austin, Christopher P; Inglese, James

    2007-12-01

    The identification of biologically active compounds from high-throughput screening (HTS) can involve considerable postscreening analysis to verify the nature of the sample activity. In this study we evaluated the performance of micro-parallel liquid chromatography (microPLC) as a separation-based enzyme assay platform for follow-up of compound activities found in quantitative HTS of two different targets, a hydrolase and an oxidoreductase. In an effort to couple secondary analysis to primary screening we explored the application of microPLC immediately after a primary screen. In microPLC, up to 24 samples can be loaded and analyzed simultaneously via high-performance liquid chromatography within a specially designed cartridge. In a proof-of-concept experiment for screen-coupled actives verification, we identified, selected, and consolidated the contents of "active" wells from a 1,536-well format HTS experiment into a 384-well plate and subsequently analyzed these samples by a 24-channel microPLC system. The method utilized 0.6% of the original 6-microl 1,536-well assay for the analysis. The analysis revealed several non-biological-based "positive" samples. The main examples included "false" enzyme activators resulting from an increase in well fluorescence due to fluorescent compound or impurity. The microPLC analysis also provided a verification of the activity of two activators of glucocerebrosidase. We discuss the benefits of microPLC and its limitations from the standpoint of ease of use and integration into a seamless postscreen workflow.

  4. A novel flow cytometric HTS assay reveals functional modulators of ATP binding cassette transporter ABCB6.

    PubMed

    Polireddy, Kishore; Khan, Mohiuddin Md Taimur; Chavan, Hemantkumar; Young, Susan; Ma, Xiaochao; Waller, Anna; Garcia, Matthew; Perez, Dominique; Chavez, Stephanie; Strouse, Jacob J; Haynes, Mark K; Bologa, Cristian G; Oprea, Tudor I; Tegos, George P; Sklar, Larry A; Krishnamurthy, Partha

    2012-01-01

    ABCB6 is a member of the adenosine triphosphate (ATP)-binding cassette family of transporter proteins that is increasingly recognized as a relevant physiological and therapeutic target. Evaluation of modulators of ABCB6 activity would pave the way toward a more complete understanding of the significance of this transport process in tumor cell growth, proliferation and therapy-related drug resistance. In addition, this effort would improve our understanding of the function of ABCB6 in normal physiology with respect to heme biosynthesis, and cellular adaptation to metabolic demand and stress responses. To search for modulators of ABCB6, we developed a novel cell-based approach that, in combination with flow cytometric high-throughput screening (HTS), can be used to identify functional modulators of ABCB6. Accumulation of protoporphyrin, a fluorescent molecule, in wild-type ABCB6 expressing K562 cells, forms the basis of the HTS assay. Screening the Prestwick Chemical Library employing the HTS assay identified four compounds, benzethonium chloride, verteporfin, tomatine hydrochloride and piperlongumine, that reduced ABCB6 mediated cellular porphyrin levels. Validation of the identified compounds employing the hemin-agarose affinity chromatography and mitochondrial transport assays demonstrated that three out of the four compounds were capable of inhibiting ABCB6 mediated hemin transport into isolated mitochondria. However, only verteporfin and tomatine hydrochloride inhibited ABCB6's ability to compete with hemin as an ABCB6 substrate. This assay is therefore sensitive, robust, and suitable for automation in a high-throughput environment as demonstrated by our identification of selective functional modulators of ABCB6. Application of this assay to other libraries of synthetic compounds and natural products is expected to identify novel modulators of ABCB6 activity. PMID:22808084

  5. Characterization of Hybrid Ferroelectric/HTS Thin Films for Tunable Microwave Components

    NASA Technical Reports Server (NTRS)

    Winters, M. D.; Mueller, C. H.; Bhasin, K. B.; Miranda, F. A.

    1996-01-01

    Since the discovery of High-Temperature-Superconductors (HTS) in 1986, a diversity of HTS-based microwave components has been demonstrated. Because of their low conductor losses, HTS-based components are very attractive for integration into microwave circuits for space communication systems. Recent advancements have made deposition of ferroelectric thin films onto HTS thin films possible. Due to the sensitivity of the ferroelectric's dielectric constant (epsilon(sub r)) to an externally applied electric field (E), ferroelectric/superconducting structures could be used in the fabrication of low loss, tunable microwave components. In this paper, we report on our study of Ba(0.5)Sr(0.5)TiO3/YBa2Cu3O(7-delta) and Ba(0.08)Sr(0.92)TiO3/YBa2Cu3O(7-delta) ferroelectric/superconducting thin films on lanthanum aluminate (LaAlO3) substrates. For the (Ba:Sr, 0.50:0.50) epitaxial sample, a epsilon(sub r) of 425 and a loss tangent (tan delta) of 0.040 were measured at 298 K, 1.0 MHz, and zero applied E. For the same sample, a epsilon(sub r) of 360 and tan delta of 0.036 were obtained at 77 K, 1.0 MHz, and zero applied E. Variations in epsilon(sub r) from 180 to 360 were observed over an applied E range of 0V/cm less than or equal to E less than or equal to 5.62 x 10(exp 4) V/cm with little change in tan delta. However, the range of epsilon(sub r) variation for the polycrystalline (Ba:Sr, 0.08:0.92) sample over 0V/cm less than or equal to E less than or equal to 4.00 x 10(exp 4) V/cm was only 3.6 percent while tan delta increased markedly. These results indicate that a lack of epitaxy between the ferroelectric and superconducting layers decreases tuning and increases microwave losses.

  6. The status and prospects for flywheels and SMES that incorporate HTS

    NASA Astrophysics Data System (ADS)

    Wolsky, A. M.

    2002-08-01

    With one firm offering to provide SMES with HTS current leads and several other entities developing flywheels with bearings that incorporate bulk ReBaCuO, the progress made toward meeting their technical goals appears promising. Another question needs attention from the research, development, and demonstration (RD&D) community: “Will technical success yield equipment that will sell?” Here, we recall what is being done and review issues touching on the specifications for equipment that customers might want. These specifications pose technical challenges that have received little attention from the community.

  7. Development of a Flat-plate Cryogenic Oscillating Heat Pipe for Improving HTS Magnet Cooling

    NASA Astrophysics Data System (ADS)

    Natsume, K.; Mito, T.; Yanagi, N.; Tamura, H.

    A new method of including cryogenic oscillating heat pipes (OHPs) in the HTS coil windings as a thermal transport device has been studied. In this work, two type of OHPs are tested in low temperature. Employed working fluids are H2, Ne, N2. We have attained high performance thermal property using a bent-pipe cryogenic OHP as a prototype. Obtained effective conductivities have reached to 46000 W/m K. Then a flat-plate cryogenic OHP has been developed, that is suitable for imbedding in magnet windings. Preliminary experiments have been conducted and the result has been promising.

  8. The status and prospects for flywheels and SMES that incorporate HTS.

    SciTech Connect

    Wolsky, A. M.; Energy Systems

    2002-08-01

    With one firm offering to provide SMES with HTS current leads and several other entities developing flywheels with bearings that incorporate bulk ReBaCuO, the progress made toward meeting their technical goals appears promising. Another question needs attention from the research, development, and demonstration (RD&D) community: 'Will technical success yield equipment that will sell?' Here, we recall what is being done and review issues touching on the specifications for equipment that customers might want. These specifications pose technical challenges that have received little attention from the community.

  9. Development of Non-destructive Evaluation System Using an HTS-SQUID Gradiometer with an External Pickup Coil

    NASA Astrophysics Data System (ADS)

    Kawano, J.; Kawauchi, S.; Ishikawa, F.; Tanabe, K.

    We are developing a new eddy-current non-destructive evaluation (NDE) system using a high-temperature superconducting quantum interference device (HTS-SQUID) gradiometer with the aim of applying it to power plants. Electric power facilities such as ducts and vessels are generally untransportable because of their size, and thus it is difficult to apply a conventional SQUID NDE system. The new NDE system employs an external Cu pickup coil which is supposed to be driven flexibly by a robot arm at room temperature and an HTS-SQUID chip which is placed in a magnetically shielded vessel. In the present research, we investigated the performance of an HTS-SQUID sensor connected with external pickup coils before mounting them to a robot arm. By varying the Cu coil conditions such as their sizes, the number of turns, and the diameter of wire, we qualitatively evaluated the frequency dependence of the effective area and the cutoff frequency.

  10. Influence of AC external magnetic field on guidance force relaxation between HTS bulk and NdFeB guideway

    NASA Astrophysics Data System (ADS)

    Zhang, Longcai; Wang, Suyu; Wang, Jiasu; Zheng, Jun

    2007-12-01

    Superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the HTS bulks are always exposed to time-varying external magnetic field, which is generated by the inhomogeneous surface magnetic field of the NdFeB guideway. So it is required to study whether the guidance force of the bulks is influenced by the inhomogeneity. In this paper, we studied the characteristics of the guidance force relaxation between the HTS bulk and the NdFeB guideway by an experiment in which AC external magnetic field generated by an electromagnet was used to simulate the time-varying external magnetic field caused by the inhomogeneity of the guideway. From the experiment results, it was found that the guidance force was decreased with the application of the AC external magnetic field, and the decay increased with the amplitude and was almost independent of the frequency.

  11. High Temperature Superconducting Degaussing-Cooling Two Hts Coils with One Cryocooler for the Littoral Combat Ship

    NASA Astrophysics Data System (ADS)

    Fitzpatrick, B. K.; Golda, E. M.; Kephart, J. T.

    2008-03-01

    The concept of creating a high temperature superconducting degaussing system has previously been studied by the Navy and shown to provide significant weight savings over conventional copper based degaussing systems. Modeling efforts have shown that in a HTS Degaussing System (HTSDG) for the Littoral Combat Ship, the dominant costs are cryocoolers. In an effort to minimize the number of cryocoolers, a two coil demonstrator cooled by one cryocooler has been constructed at NSWCCD Philadelphia. The demonstration consists of two 22 m long sections of flexible cryostat that are electrically isolated but connected in series through two junction boxes for serial gas flow. Within each cryostat section, 12 turns of HTS represent a vertical and horizontal degaussing coil. Use of Helium as the working fluid reduces safety impacts and allows higher current density in the HTS conductor due to lower temperature operation. Design, testing results, and lessons learned from the installation and operation of this cable are presented in this paper.

  12. Plate-fin Heat-exchangers for a 10 kW Brayton Cryocooler and a 1 km HTS Cable

    NASA Astrophysics Data System (ADS)

    Chang, Ho-Myung; Gwak, Kyung Hyun; Jung, Seyong; Yang, Hyung Suk; Hwang, Si-Dole

    Plate-fin heat exchangers (PFHX) are designed and fabricated for a cryogenic cooling system, serving for a 10 kW Brayton cryocooler and a 1 km HTS transmission cable under development in Korea. To achieve compactness and thermal efficiency at the same time, a recuperative HX for Brayton cycle and a sub-cooling HX of liquid nitrogen for HTS cable are designed as integrated parts. A key design feature is focused on the coldest part of sub-cooling HX, where the streams of liquid nitrogen and refrigerant (helium gas) are arranged as two-pass cross-flow so that the risk of freeze-out of liquid nitrogen can be reduced. Details of hardware PFHX design are presented and discussed towards its immediate application to the HTS cable system.

  13. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by authorized contractors shall be in accordance with FPMR 41 CFR 101-26.508-1. However, if adequate... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data...

  14. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by authorized contractors shall be in accordance with FPMR 41 CFR 101-26.508-1. However, if adequate... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data...

  15. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ..., 2009, the Commission established a schedule for the conduct of the review (74 FR 43155, August 26, 2009... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade...

  16. Astronaut Rich Clifford inserts tape into payload high data recorder

    NASA Technical Reports Server (NTRS)

    1994-01-01

    On the Space Shuttle Endeavour's aft flight deck, Astronaut Michael R. (Rich) Clifford, mission specialist, inserts a tape in the payload high rate recorder. Three of these state-of-the-art recorders captured four times the amount of data that could be radioed to the ground.

  17. Corrosion of metal particle and metal evaporated tapes

    NASA Astrophysics Data System (ADS)

    Speliotis, Dennis E.

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  18. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  19. Extendable nickel complex tapes that reach NIR absorptions.

    PubMed

    Audi, Hassib; Chen, Zhongrui; Charaf-Eddin, Azzam; D'Aléo, Anthony; Canard, Gabriel; Jacquemin, Denis; Siri, Olivier

    2014-12-14

    Stepwise synthesis of linear nickel complex oligomer tapes with no need for solid-phase support has been achieved. The control of the length in flat arrays allows a fine-tuning of the absorption properties from the UV to the NIR region.

  20. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  1. STS-46 Special Events Resource Tape, Part 1 of 2

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Footage shows the inflight interviews of the crew of the STS-46 Atlantis Orbiter. An Italian VIP call and press conference (both spoken in Italian) are seen, and Mission Specialist Franklin R. Chang-Diaz participates in a Costa Rican VIP call (spoken in Spanish). See also 'STS-46 Special Events Resource Tape, Part 2 of 2'.

  2. An Important Adjunct for Counselors: Video Taped Role Playing

    ERIC Educational Resources Information Center

    Soltys, Michael P.

    1971-01-01

    Through effective use of video tape students can become better prepared for the interview, more confident and poised, and better able to relate more effectively with people. The work described in this article is related to the content of a recent CPS workshop reported in this issue. (Author)

  3. Kodak phase-change media for optical tape applications

    NASA Technical Reports Server (NTRS)

    Tyan, Yuan-Sheng; Preuss, Donald R.; Olin, George R.; Vazan, Fridrich; Pan, Kee-Chuan; Raychaudhuri, Pranab. K.

    1993-01-01

    The SbInSn phase-change write-once optical medium developed by Eastman Kodak Company is particularly suitable for development into the next generation optical tape media. Its performance for optical recording has already been demonstrated in some of the highest performance optical disk systems. Some of the key performance features are presented.

  4. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800...

  5. A new tape product for optical data storage

    NASA Technical Reports Server (NTRS)

    Larsen, T. L.; Woodard, F. E.; Pace, S. J.

    1993-01-01

    A new tape product has been developed for optical data storage. Laser data recording is based on hole or pit formation in a low melting metallic alloy system. The media structure, sputter deposition process, and media characteristics, including write sensitivity, error rates, wear resistance, and archival storage are discussed.

  6. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  7. The Taped Monologue as Narrative Technique for Reflective Practice

    ERIC Educational Resources Information Center

    Ford, Keith

    2016-01-01

    In this article, I describe how an EFL teacher engaged in a process of reflective practice. As she looked back on her teaching career, she explored the critical incidents, principles, and practices that have informed her present teaching identity. I focus on how a taped monologue narrative technique was used, and on the rationale, practice, and…

  8. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  9. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  10. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  11. Experimental research on tape spring supported space inflatable structures

    NASA Astrophysics Data System (ADS)

    Cook, Andrew J.; Walker, Scott J. I.

    2016-01-01

    This paper presents experimental research that continues the development of inflatable hybrid structures for space applications. Inflatables provide a concept with much scope for further incorporation into the structures of future spacecraft. They offer considerable savings in mass and stowed volume for spacecraft, providing possible reductions in satellite costs. Existing boom configurations make use of inflatables including solar arrays and the NGST sunshield. However these typically soft systems could be improved by incorporating tape springs as structural stiffeners along the length of the boom, creating hybrid structures. This research builds on previous experimental work undertaken at the University of Southampton looking at cantilever inflatable and hybrid booms. The focus of this research is to identify the structural performance improvement of adding tape springs to cantilever inflatable booms. This is achieved by tip deflection testing to determine the bending moment and rigidity performances of these structures allowing a comparison between the two technologies. Several hybrid booms are created and tested in various orientations to identify the optimal tape spring effectiveness. It was found that adding a pair of tape springs will increase stiffness of the hybrid structure by up to 4.9 times for an increase of 2.4 times the boom mass.

  12. STS 110 Mission Highlights Resource Tape. Part 2 of 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A continuation of 'STS 110 Mission Highlights Resource Tape'. This video, Part 2 of 4, shows footage from flight days 3 through 5 of STS-110. The flight crew includes Michael J. Bloomfield, Commander; Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. The coverage from flight day 3 includes docking replays of Atlantis and the International Space Station (ISS), and postdocking procedures, as well as intermingling of the flight crew with the Expedition 4 crew (Yury I. Onufrienko, Commander; Daniel W. Bursch, Flight Engineer; Carl E. Walz, Flight Engineer) of the ISS. Flight day 4 includes an EVA (extravehicular activity) in which Walheim and Smith lift the S0 Truss from the payload bay, and temporarily clamp it onto the Destiny laboratory. On flight day 5 a suite of spaceborne experiments (not shown) arrives at Destiny, including protein crystal growth and wheat plant growth experiments. Notable footage includes Hawaii, New Zealand, and sunrise on Atlantis. An unknown object steaks across the field of view during the video, with the Earth in the background. The activities of the other flight days can be seen on 'STS 110 Mission Highlights Resource Tape, Part 1 of 4' (internal ID 2002137575), 'STS 110 Mission Highlights Resource Tape, Part 3 of 4' (internal ID 2002137574), and 'STS 110 Mission Highlights Resource Tape, Part 4 of 4' (internal ID 2002137517).

  13. Tape casting and partial melting of Bi-2212 thick films

    SciTech Connect

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  14. Privacy: The Reporter, the Telephone, and the Tape Recorder.

    ERIC Educational Resources Information Center

    Riley, Sam G.; Wiessler, Joel M.

    Federal and state law provides, for the most part, little specific guidance to persons tape recording their own telephone calls for their own record-keeping purposes. In a specific case, a Pennsylvania newsman was prosecuted in 1972 on charges of wiretapping his own telephone conversations without notice to the other parties in the calls. A review…

  15. [Recovery of blood traces with scenesafe FAST tape].

    PubMed

    Keller, Eva; Looser, Markus; Bieri, Hans-Peter; Kübler, Eric; Balitzki, Beate

    2012-01-01

    For complete and conclusive DNA profiling a sufficient amount of DNA must be available. For that, biological traces are recovered from crime scenes using special trace recovery material. The current method to collect biological traces for DNA analysis is to wipe them off with cotton swabs. However, for a few years the use of adhesive tapes has also been described for the recovery of evidence. In 2009, an adhesive tape was launched which was specially developed for the collection of biological traces. This product called Scenesafe FAST Tape (SSF) was investigated in this work to give recommendations for its use in evidence recovery. The results of this work show that the DNA can be extracted from the SSF very well. However, the tapes seem less suitable for direct use at the crime scene, as they are not flexible enough for adaptation to different crime scene conditions and the risk of contamination is higher than when collecting evidence with cotton swabs. Neither SSF nor cotton swabs are optimal for all requirements. The best method to recover biological evidence is still dependent on the surface material and the circumstances at the crime scene.

  16. Extendable nickel complex tapes that reach NIR absorptions.

    PubMed

    Audi, Hassib; Chen, Zhongrui; Charaf-Eddin, Azzam; D'Aléo, Anthony; Canard, Gabriel; Jacquemin, Denis; Siri, Olivier

    2014-12-14

    Stepwise synthesis of linear nickel complex oligomer tapes with no need for solid-phase support has been achieved. The control of the length in flat arrays allows a fine-tuning of the absorption properties from the UV to the NIR region. PMID:25348258

  17. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  18. Probe molecules (PrM) approach in adverse outcome pathway (AOP) based high throughput screening (HTS): in vivo discovery for developing in vitro target methods

    EPA Science Inventory

    Efficient and accurate adverse outcome pathway (AOP) based high-throughput screening (HTS) methods use a systems biology based approach to computationally model in vitro cellular and molecular data for rapid chemical prioritization; however, not all HTS assays are grounded by rel...

  19. Operating characteristic analysis of a 400 mH class HTS DC reactor in connection with a laboratory scale LCC type HVDC system

    NASA Astrophysics Data System (ADS)

    Kim, Sung-Kyu; Kim, Kwangmin; Park, Minwon; Yu, In-Keun; Lee, Sangjin

    2015-11-01

    High temperature superconducting (HTS) devices are being developed due to their advantages. Most line commutated converter based high voltage direct current (HVDC) transmission systems for long-distance transmission require large inductance of DC reactor; however, generally, copper-based reactors cause a lot of electrical losses during the system operation. This is driving researchers to develop a new type of DC reactor using HTS wire. The authors have developed a 400 mH class HTS DC reactor and a laboratory scale test-bed for line-commutated converter type HVDC system and applied the HTS DC reactor to the HVDC system to investigate their operating characteristics. The 400 mH class HTS DC reactor is designed using a toroid type magnet. The HVDC system is designed in the form of a mono-pole system with thyristor-based 12-pulse power converters. In this paper, the investigation results of the HTS DC reactor in connection with the HVDC system are described. The operating characteristics of the HTS DC reactor are analyzed under various operating conditions of the system. Through the results, applicability of an HTS DC reactor in an HVDC system is discussed in detail.

  20. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.