Science.gov

Sample records for 3-d shape measurement

  1. Automated full-3D shape measurement of cultural heritage objects

    NASA Astrophysics Data System (ADS)

    Sitnik, Robert; Karaszewski, Maciej; Zaluski, Wojciech; Bolewicki, Pawel

    2009-07-01

    In this paper a fully automated 3D shape measurement system is presented. It consists of rotary stage for cultural heritage objects placement, vertical linear stage with mounted robot arm (with six degrees of freedom) and structured light measurement set-up mounted to its head. All these manipulation devices are automatically controlled by collision detection and next-best-view calculation modules. The goal of whole system is to automatically (without any user attention) and rapidly (from days and weeks to hours) measure whole object. Measurement head is automatically calibrated by the system and its possible working volume starts from centimeters and ends up to one meter. We present some measurement results with different working scenarios along with discussion about its possible applications.

  2. High-speed 3D shape measurement using array projection

    NASA Astrophysics Data System (ADS)

    Heist, Stefan; Sieler, Marcel; Breitbarth, Andreas; Kühmstedt, Peter; Notni, Gunther

    2013-04-01

    Measuring the three-dimensional (3D) surface shape of objects in real time has become an important task e.g. in industrial quality management or medical sciences. Stereo vision-based arrangements in connection with pattern projection offer high data acquisition speed and low computation time. However, these coded-light techniques are limited by the projection speed which is conventionally in the range of 200. . .250Hz. In this contribution, we present the concepts and a realized setup of a so-called 3D array projector. It is ultra-slim, but nonetheless able to project fixed patterns with high brightness and depth of focus. Furthermore, frame rates up to the 100 kHz range are achievable without any need of mechanically moving parts since the projection speed is limited mainly by the switching frequency of the used LEDs. According to the measurement requirements, type and structure of the patterns can be chosen almost freely: linear or sinusoidal fringes, binary codes such as the Gray code, square, hexagonal or random patterns and many more. First investigations on the functionality of such a 3D array projector were conducted using a prototype with a combination of Gray codes and phase-shifted sinusoidal fringes. Our contribution proves the high brightness of the proposed projector, its sharpness and the good Michelson contrast of the fringe patterns. We deal with the patterns' homogeneity and the accuracy of the phase shift between the sinusoidal patterns. Furthermore, we present first measurement results and outline future research which is, inter alia, addressed to the use of other structured light techniques with the help of new purpose-built 3D array projector prototypes.

  3. Fast 3D shape measurements using laser speckle projection

    NASA Astrophysics Data System (ADS)

    Schaffer, Martin; Grosse, Marcus; Harendt, Bastian; Kowarschik, Richard

    2011-05-01

    3D measurement setups based on structured light projection are widely used for many industrial applications. Due to intense research in the past the accuracy is comparably high in connection with relatively low cost of the equipment. But facing higher acquisition rates in industries especially for chain assembling lines there are still hurdles to take when accelerating 3D measurements and at the same time retaining accuracies. We developed a projection technique that uses laser speckles to enable fast 3D measurements with statistically structured light patterns. In combination with a temporal correlation technique dense and accurate 3D reconstructions at nearly video rate can be achieved.

  4. 3D-Measuring for Head Shape Covering Hair

    NASA Astrophysics Data System (ADS)

    Kato, Tsukasa; Hattori, Koosuke; Nomura, Takuya; Taguchi, Ryo; Hoguro, Masahiro; Umezaki, Taizo

    3D-Measuring is paid to attention because 3D-Display is making rapid spread. Especially, face and head are required to be measured because of necessary or contents production. However, it is a present problem that it is difficult to measure hair. Then, in this research, it is a purpose to measure face and hair with phase shift method. By using sine images arranged for hair measuring, the problems on hair measuring, dark color and reflection, are settled.

  5. An optical real-time 3D measurement for analysis of facial shape and movement

    NASA Astrophysics Data System (ADS)

    Zhang, Qican; Su, Xianyu; Chen, Wenjing; Cao, Yiping; Xiang, Liqun

    2003-12-01

    Optical non-contact 3-D shape measurement provides a novel and useful tool for analysis of facial shape and movement in presurgical and postsurgical regular check. In this article we present a system, which allows a precise 3-D visualization of the patient's facial before and after craniofacial surgery. We discussed, in this paper, the real time 3-D image capture, processing and the 3-D phase unwrapping method to recover complex shape deformation when the movement of the mouth. The result of real-time measurement for facial shape and movement will be helpful for the more ideal effect in plastic surgery.

  6. Status of 3D Ice Shape Measurement Effort

    NASA Technical Reports Server (NTRS)

    Lee, Sam

    2011-01-01

    (1) Main goal of the Airframe Icing Technical Challenge is to achieve acceptance of experimental and computational icing simulation tools -SupercooledLarge Droplet Icing (SLD) conditions -3D airframe components including swept wings; (2) It is necessary to develop suitable means of recording and archiving fully 3D descriptions of experimental ice accretion geometry; (3) Past research has shown that commercial laser scanners have the potential to be adapted to this task; and (4) A research plan has been developed to implement and validate the use of this technology for experimental ice accretions.

  7. 3D shape measurements for non-diffusive objects using fringe projection techniques

    NASA Astrophysics Data System (ADS)

    Su, Wei-Hung; Tseng, Bae-Heng; Cheng, Nai-Jen

    2013-09-01

    A scanning approach using holographic techniques to perform the 3D shape measurement for a non-diffusive object is proposed. Even though the depth discontinuity on the inspected surface is pretty high, the proposed method can retrieve the 3D shape precisely.

  8. Fast 3D shape measurement using Fourier transform profilometry without phase unwrapping

    NASA Astrophysics Data System (ADS)

    Song, Kechen; Hu, Shaopeng; Wen, Xin; Yan, Yunhui

    2016-09-01

    This paper presents a novel, simple, yet fast 3D shape measurement method using Fourier transform profilometry. Different from the conventional Fourier transform profilometry, this proposed method introduces the binocular stereo vision and employs two image pairs (i.e., original image pairs and fringe image pairs) to restructure 3D shape. In this proposed method, instead of phase unwrapping algorithm, a coarse disparity map is adopted as a constraint condition to realize phase matching using wrapped phase. Since the local phase matching and sub-pixel disparity refinement are proposed to obtain high measuring accuracy, high-quality phase is not required. The validity of the proposed method is verified by experiments.

  9. 3D shape measurement of the aspheric mirror by advanced phase measuring deflectometry.

    PubMed

    Tang, Yan; Su, Xianyu; Liu, Yuankun; Jing, Hailong

    2008-09-15

    An advanced Phase Measuring Deflectometry(PMD) is proposed to measure the three dimensional (3D) shape of the aspheric mirror. In the measurement process, a liquid crystal display(LCD)screen displaying sinusoidal fringe patterns and a camera observing the fringe patterns reflected via the tested mirror, are moved along the tested mirror optical axis, respectively. At each movement position, the camera records the fringe patterns of the screen located at two different positions. Using these fringe patterns, every camera pixels can find a corresponding point on the tested mirror and gets its coordinate and slope. By integrating, the 3D shape of the tested mirror can be reconstructed. Compared with the traditional PMD, this method doesn???t need complex calibration and can measure the absolute height of the aspheric mirror which has large range of surface geometries unambiguously. Furthermore, this method also has strong anti-noise ability. Computer simulations and preliminary experiment validate the feasibility of this method. PMID:18795046

  10. Real-time, high-accuracy 3D imaging and shape measurement.

    PubMed

    Nguyen, Hieu; Nguyen, Dung; Wang, Zhaoyang; Kieu, Hien; Le, Minh

    2015-01-01

    In spite of the recent advances in 3D shape measurement and geometry reconstruction, simultaneously achieving fast-speed and high-accuracy performance remains a big challenge in practice. In this paper, a 3D imaging and shape measurement system is presented to tackle such a challenge. The fringe-projection-profilometry-based system employs a number of advanced approaches, such as: composition of phase-shifted fringe patterns, externally triggered synchronization of system components, generalized system setup, ultrafast phase-unwrapping algorithm, flexible system calibration method, robust gamma correction scheme, multithread computation and processing, and graphics-processing-unit-based image display. Experiments have shown that the proposed system can acquire and display high-quality 3D reconstructed images and/or video stream at a speed of 45 frames per second with relative accuracy of 0.04% or at a reduced speed of 22.5 frames per second with enhanced accuracy of 0.01%. The 3D imaging and shape measurement system shows great promise of satisfying the ever-increasing demands of scientific and engineering applications. PMID:25967028

  11. Development and application of 3-D foot-shape measurement system under different loads

    NASA Astrophysics Data System (ADS)

    Liu, Guozhong; Wang, Boxiong; Shi, Hui; Luo, Xiuzhi

    2008-03-01

    The 3-D foot-shape measurement system under different loads based on laser-line-scanning principle was designed and the model of the measurement system was developed. 3-D foot-shape measurements without blind areas under different loads and the automatic extraction of foot-parameter are achieved with the system. A global calibration method for CCD cameras using a one-axis motion unit in the measurement system and the specialized calibration kits is presented. Errors caused by the nonlinearity of CCD cameras and other devices and caused by the installation of the one axis motion platform, the laser plane and the toughened glass plane can be eliminated by using the nonlinear coordinate mapping function and the Powell optimized method in calibration. Foot measurements under different loads for 170 participants were conducted and the statistic foot parameter measurement results for male and female participants under non-weight condition and changes of foot parameters under half-body-weight condition, full-body-weight condition and over-body-weight condition compared with non-weight condition are presented. 3-D foot-shape measurement under different loads makes it possible to realize custom-made shoe-making and shows great prosperity in shoe design, foot orthopaedic treatment, shoe size standardization, and establishment of a feet database for consumers and athletes.

  12. 3D shape measurements with a single interferometric sensor for in-situ lathe monitoring

    NASA Astrophysics Data System (ADS)

    Kuschmierz, R.; Huang, Y.; Czarske, J.; Metschke, S.; Löffler, F.; Fischer, A.

    2015-05-01

    Temperature drifts, tool deterioration, unknown vibrations as well as spindle play are major effects which decrease the achievable precision of computerized numerically controlled (CNC) lathes and lead to shape deviations between the processed work pieces. Since currently no measurement system exist for fast, precise and in-situ 3d shape monitoring with keyhole access, much effort has to be made to simulate and compensate these effects. Therefore we introduce an optical interferometric sensor for absolute 3d shape measurements, which was integrated into a working lathe. According to the spindle rotational speed, a measurement rate of 2,500 Hz was achieved. In-situ absolute shape, surface profile and vibration measurements are presented. While thermal drifts of the sensor led to errors of several mµm for the absolute shape, reference measurements with a coordinate machine show, that the surface profile could be measured with an uncertainty below one micron. Additionally, the spindle play of 0.8 µm was measured with the sensor.

  13. ARCHAEO-SCAN: Portable 3D shape measurement system for archaeological field work

    NASA Astrophysics Data System (ADS)

    Knopf, George K.; Nelson, Andrew J.

    2004-10-01

    Accurate measurement and thorough documentation of excavated artifacts are the essential tasks of archaeological fieldwork. The on-site recording and long-term preservation of fragile evidence can be improved using 3D spatial data acquisition and computer-aided modeling technologies. Once the artifact is digitized and geometry created in a virtual environment, the scientist can manipulate the pieces in a virtual reality environment to develop a "realistic" reconstruction of the object without physically handling or gluing the fragments. The ARCHAEO-SCAN system is a flexible, affordable 3D coordinate data acquisition and geometric modeling system for acquiring surface and shape information of small to medium sized artifacts and bone fragments. The shape measurement system is being developed to enable the field archaeologist to manually sweep the non-contact sensor head across the relic or artifact surface. A series of unique data acquisition, processing, registration and surface reconstruction algorithms are then used to integrate 3D coordinate information from multiple views into a single reference frame. A novel technique for automatically creating a hexahedral mesh of the recovered fragments is presented. The 3D model acquisition system is designed to operate from a standard laptop with minimal additional hardware and proprietary software support. The captured shape data can be pre-processed and displayed on site, stored digitally on a CD, or transmitted via the Internet to the researcher's home institution.

  14. 3D shape measurement for moving scenes using an interlaced scanning colour camera

    NASA Astrophysics Data System (ADS)

    Cao, Senpeng; Cao, Yiping; Lu, Mingteng; Zhang, Qican

    2014-12-01

    A Fourier transform deinterlacing algorithm (FTDA) is proposed to eliminate the blurring and dislocation of the fringe patterns on a moving object captured by an interlaced scanning colour camera in phase measuring profilometry (PMP). Every frame greyscale fringe from three colour channels of every colour fringe is divided into even and odd field fringes respectively, each of which is respectively processed by FTDA. All of the six frames deinterlaced fringes from one colour fringe form two sets of three-step phase-shifted greyscale fringes, with which two 3D shapes corresponding to two different moments are reconstructed by PMP within a frame period. The deinterlaced fringe is identical with the exact frame fringe at the same moment theoretically. The simulation and experiments show its feasibility and validity. The method doubles the time resolution, maintains the precision of the traditional phase measurement profilometry, and has potential applications in the moving and online object’s 3D shape measurements.

  15. Deformation and 3D-shape measurement system based on phase-shifting digital holography

    NASA Astrophysics Data System (ADS)

    Lai, Songcan; Kolenovic, Ervin; Osten, Wolfgang; Jueptner, Werner P. O.

    2002-05-01

    This paper presents an endoscopic digital holographic interferometry system which is based on phase-shifting in-line digital holography. The system is able to measure both the shape and deformation of an object with the advantages of digital holography, such as real-time processing of the hologram. Two theoretical problems are briefly described: phase-shifting in- line holography and hologram data re-sampling for 2-wavelength contouring. In addition, initial experimental results of the deformation of a metal piece and surface 3D-shape measurement of a bottle cap are given.

  16. 3D shape measurement of shoeprint impression with structured illumination and fringe pattern analysis

    NASA Astrophysics Data System (ADS)

    Su, Xianyu; Cao, Yiping; Xiang, Liqun; Chen, Wenjing

    2002-06-01

    The shoeprint impressions of suspect left at the crime scene can sometimes tell investigators what type of shoes to be looked for. These shoeprint impressions as one of the important evidence are useful in the detection of criminals. In this paper we propose a novel technique for identifying and analyzing the 3D characteristics of shoeprint impressions. We also design 3D shoeprint impression analysis system based on the combination the 3D shape measurement with structured illumination and fringe pattern analysis. We give a detail discussion on the principle and configuration of the system. Laboratory experiments show the technique is efficient in the detection of shoeprint and in the offering the reference for judicial evidence.

  17. Small pitch fringe projection method with multiple linear fiber arrays for 3D shape measurement

    NASA Astrophysics Data System (ADS)

    Hayashi, Takumi; Fujigaki, Motoharu; Murata, Yorinobu

    2014-07-01

    3-D shape measurement systems by contactless method are required in the quality inspections of metal molds and electronic parts in industrial fields. A grating projection method with phase-shifting method has advantages of high precision and high speed. Recently, the size of a BGA (ball grid array) becomes smaller. So the pitch of a grating pattern projected onto the specimen should be smaller. In conventional method, fringe pattern is projected using an imaging lens. The focal depth becomes smaller in the case of reduced projection. It is therefore difficult to project a grating pattern with small pitch onto an object with large incident angles. Authors recently proposed a light source stepping method using a linear LED device. It is easy to shrink the projected grating pitch with a lens because this projection method does not use an imaging lens. The pitch of the projected grating depends on the width of the light source. There is a limit to shrink the projected grating pitch according to the size of the LED chip. In this paper, a small pitch fringe projection method with multiple linear fiber arrays for 3D shape measurement is proposed. The width of the fiber array is 30μm. It is one digit smaller than the width of the LED chip. The experimental result of 3-D shape measurement with small pitch projection with large incident angles is shown.

  18. Digital holographic measurements of shape and 3D sound-induced displacements of Tympanic Membrane

    PubMed Central

    Lu, Weina; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J

    2014-01-01

    Acoustically-induced vibrations of the Tympanic Membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and 3D displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. In this paper, shape and sound-induced 3D displacements of the TM in cadaveric chinchillas are measured by a lensless Dual-Wavelength Digital Holography system (DWDHS). The DWDHS consists of Laser Delivery (LD), Optical Head (OH), and Computing Platform (CP) subsystems. Shape measurements are performed in double-exposure mode and with the use of two wavelengths of a tunable laser while nanometer-scale displacements are measured along a single sensitivity direction and with a constant wavelength. In order to extract the three principal components of displacement in full-field-of-view, and taking into consideration the anatomical dimensions of the TM, we combine principles of thin-shell theory together with both, displacement measurements along the single sensitivity vector and TM surface shape. To computationally test this approach, Finite Element Methods (FEM) are applied to the study of artificial geometries. PMID:24790255

  19. Digital holographic measurements of shape and 3D sound-induced displacements of Tympanic Membrane.

    PubMed

    Khaleghi, Morteza; Lu, Weina; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J

    2013-10-01

    Acoustically-induced vibrations of the Tympanic Membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and 3D displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. In this paper, shape and sound-induced 3D displacements of the TM in cadaveric chinchillas are measured by a lensless Dual-Wavelength Digital Holography system (DWDHS). The DWDHS consists of Laser Delivery (LD), Optical Head (OH), and Computing Platform (CP) subsystems. Shape measurements are performed in double-exposure mode and with the use of two wavelengths of a tunable laser while nanometer-scale displacements are measured along a single sensitivity direction and with a constant wavelength. In order to extract the three principal components of displacement in full-field-of-view, and taking into consideration the anatomical dimensions of the TM, we combine principles of thin-shell theory together with both, displacement measurements along the single sensitivity vector and TM surface shape. To computationally test this approach, Finite Element Methods (FEM) are applied to the study of artificial geometries. PMID:24790255

  20. Measuring the 3D shape of high temperature objects using blue sinusoidal structured light

    NASA Astrophysics Data System (ADS)

    Zhao, Xianling; Liu, Jiansheng; Zhang, Huayu; Wu, Yingchun

    2015-12-01

    The visible light radiated by some high temperature objects (less than 1200 °C) almost lies in the red and infrared waves. It will interfere with structured light projected on a forging surface if phase measurement profilometry (PMP) is used to measure the shapes of objects. In order to obtain a clear deformed pattern image, a 3D measurement method based on blue sinusoidal structured light is proposed in this present work. Moreover, a method for filtering deformed pattern images is presented for correction of the unwrapping phase. Blue sinusoidal phase-shifting fringe pattern images are projected on the surface by a digital light processing (DLP) projector, and then the deformed patterns are captured by a 3-CCD camera. The deformed pattern images are separated into R, G and B color components by the software. The B color images filtered by a low-pass filter are used to calculate the fringe order. Consequently, the 3D shape of a high temperature object is obtained by the unwrapping phase and the calibration parameter matrixes of the DLP projector and 3-CCD camera. The experimental results show that the unwrapping phase is completely corrected with the filtering method by removing the high frequency noise from the first harmonic of the B color images. The measurement system can complete the measurement in a few seconds with a relative error of less than 1 : 1000.

  1. Gray coded trapezoidal fringes for 3-D surface-shape measurement

    NASA Astrophysics Data System (ADS)

    Pérez, Oscar G.; Flores, Jorge L.; García-Torales, G.; Muñoz-G, J. A.; Soto, Horacio; Balderas, Sandra E.

    2014-09-01

    We propose a two-step trapezoidal-pattern phase-shifting method for 3-D surface-shape measurements. Shape measurements by trapezoidal phase-shifting methods require high-quality trapezoidal patterns. Furthermore, most of the video projectors are nonlinear, making it difficult to generate high quality phase without nonlinearity calibration and correction. To overcome the limitations, we propose a method for synthesizing trapezoidal intensity fringes as a way to solve the problems caused by projector/camera gamma nonlinearity. The fringe generation technique consists of projecting and acquiring a temporal sequence of strictly binary color patterns (Gray code), whose (adequately weighted) average leads to trapezoidal fringe patterns with the required number of bits, which allows a reliable three-dimensional profile reconstruction using phase-shifting methods. Validation experiments are presented.

  2. 3-D ice shape measurements using mid-infrared laser scanning.

    PubMed

    Gong, Xiaoliang; Bansmer, Stephan

    2015-02-23

    A general approach based on mid-infrared (MIR) laser scanning is proposed to measure the 3-D ice shape no matter whether the ice is composed of clear ice, rime ice, mixed ice, or even supercooled water droplets or films. This is possible because MIR radiation penetrates ice and water only within a depth of less than 10 micrometers. First, an MIR laser point scanning technique is implemented and verified on transparent glass and clear ice. Then, to improve efficiency, an MIR laser line scanning method is developed and validated on different models. At last, several sequential MIR laser line scans are applied to trace the 3-D shape evolution of the continuous ice accretion on an airfoil in an icing wind tunnel. The ice growth process can be well observed in the results. The MIR scan shows a good agreement with the traditional visible laser scan on a plastic replication of the final ice shape made by the mold and casting method. PMID:25836526

  3. Novel high speed method using gray level vector modulation for 3D shape measurement

    NASA Astrophysics Data System (ADS)

    Lin, Gui-Wen; Li, Dong; Tian, Jin-Dong

    2014-11-01

    Binocular Vision Technique is widely used in three-dimensional (3-D) measurement. Matching of pictures captured from two cameras is the most critical and difficult step in 3-D shape reconstruction. The method combines codedstructured light and spatial phase is usually adopted. However, being time consuming in matching, this method could not meet the requirements of real-time 3-D vision. In order to satisfy the high speed characteristic of real-time measurement, a novel method using gray level vector modulation is introduced. Combining binary code with gray coding principle, new coding patterns using gray level vector method is designed and projected onto the object surface. Each pixel corresponds to the designed sequence of gray values as a feature vector. The unique gray level vector is then dimensionally reduced to a resulting value which could be used as characteristic information for binocular matching. Experimental results further demonstrated the correctness and feasibility of the proposed method with fewer component patterns and less computational time.

  4. Camera-based speckle noise reduction for 3-D absolute shape measurements.

    PubMed

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen; Fischer, Andreas

    2016-05-30

    Simultaneous position and velocity measurements enable absolute 3-D shape measurements of fast rotating objects for instance for monitoring the cutting process in a lathe. Laser Doppler distance sensors enable simultaneous position and velocity measurements with a single sensor head by evaluating the scattered light signals. The superposition of several speckles with equal Doppler frequency but random phase on the photo detector results in an increased velocity and shape uncertainty, however. In this paper, we present a novel image evaluation method that overcomes the uncertainty limitations due to the speckle effect. For this purpose, the scattered light is detected with a camera instead of single photo detectors. Thus, the Doppler frequency from each speckle can be evaluated separately and the velocity uncertainty decreases with the square root of the number of camera lines. A reduction of the velocity uncertainty by the order of one magnitude is verified by the numerical simulations and experimental results, respectively. As a result, the measurement uncertainty of the absolute shape is not limited by the speckle effect anymore. PMID:27410133

  5. 3D shape measurement with binary phase-shifted technique and digital filters

    NASA Astrophysics Data System (ADS)

    Silva, Adriana; Legarda-Saenz, Ricardo; García-Torales, G.; Balderas-Mata, Sandra; Flores, Jorge L.

    2014-09-01

    Shape measurements by sinusoidal phase-shifting methods require high-quality sinusoidal fringes. Furthermore, most of the video projectors are nonlinear, making it difficult to generate high quality phase without nonlinearity calibration and correction. To overcome the limitations of the conventional digital fringe projection techniques, we proposed a method that involves the projection of digital binary patterns generated by the pulse-width modulation (PWM). We will demonstrate that applying digital filtering, in particular, low pass filters, one can obtain a high-quality sinusoidal pattern. Which in combination with phase-shifting methods, allows a reliable 3-D profiling surface reconstruction at large timerates. Validation experiments using a commercial video projector are presented.

  6. Real-time 3D shape measurement with digital stripe projection by Texas Instruments Micro Mirror Devices DMD

    NASA Astrophysics Data System (ADS)

    Frankowski, Gottfried; Chen, Mai; Huth, Torsten

    2000-03-01

    The fast, contact-free and highly precise shape measurement of technical objects is of key importance in the scientific- technological area as well as the area of practical measurement technology. The application areas of contact- free surface measurement extend across widely different areas, e.g., the automation of production processes, the measurement and inspection of components in microsystem technology or the fast 3D in-vivo measurement of human skin surfaces in cosmetics and medical technology. This paper describes methodological and technological possibilities as well as measurement technology applications for fast optical 3D shape measurements using micromirror-based high-velocity stripe projection. Depending on the available projector and camera facilities, it will be possible to shoot and evaluate compete 3D surface profiles within only a few milliseconds.

  7. Real-time 3-D shape measurement with composite phase-shifting fringes and multi-view system.

    PubMed

    Tao, Tianyang; Chen, Qian; Da, Jian; Feng, Shijie; Hu, Yan; Zuo, Chao

    2016-09-01

    In recent years, fringe projection has become an established and essential method for dynamic three-dimensional (3-D) shape measurement in different fields such as online inspection and real-time quality control. Numerous high-speed 3-D shape measurement methods have been developed by either employing high-speed hardware, minimizing the number of pattern projection, or both. However, dynamic 3-D shape measurement of arbitrarily-shaped objects with full sensor resolution without the necessity of additional pattern projections is still a big challenge. In this work, we introduce a high-speed 3-D shape measurement technique based on composite phase-shifting fringes and a multi-view system. The geometry constraint is adopted to search the corresponding points independently without additional images. Meanwhile, by analysing the 3-D position and the main wrapped phase of the corresponding point, pairs with an incorrect 3-D position or a considerable phase difference are effectively rejected. All of the qualified corresponding points are then corrected, and the unique one as well as the related period order is selected through the embedded triangular wave. Finally, considering that some points can only be captured by one of the cameras due to the occlusions, these points may have different fringe orders in the two views, so a left-right consistency check is employed to eliminate those erroneous period orders in this case. Several experiments on both static and dynamic scenes are performed, verifying that our method can achieve a speed of 120 frames per second (fps) with 25-period fringe patterns for fast, dense, and accurate 3-D measurement. PMID:27607632

  8. A new 3D shape measurement method using digital fringe projection technique

    NASA Astrophysics Data System (ADS)

    Zhang, Jiarui; Zhang, Yingjie; Yu, Mingrang; Xiang, Dehu

    2015-10-01

    This paper proposes a novel optical three-dimensional (3D) measurement method using the traditional space-time stereo system. In the proposed method, the projector not only shoots fringe pattern onto the measurement object to achieve precise matching, but also plays a vital role in the 3D information calculation. With the combination of two cameras and a projector, two digital fringe projection (DFP) measurement systems and one traditional space-time stereo measurement system can be obtained. In another word, the measurand will be measured three times simultaneously, which results in three independent point clouds of the same region of the object to be measured. So it is necessary to register these three sets of points for obtaining one final data set. The iterative closest points (ICP) method, which is known as the most popular registration approach, is sensitive to the initial estimation of the transformation between the two sets of points to be matched. Thus, a robust rough registration, which is introduced from Natasha, is useful for ICP to realize accurate registration. After registration, a scattered point set with redundant and errors, which are caused by overlapping, is obtained. Then some local surfaces are constructed for those overlapping regions using the moving least squares (MLS) method, and the points extracted from those surfaces are used to replace the points of the overlapping regions. Finally, a simplified, precise point cloud can be obtained.

  9. Shape measurement by a multi-view methodology based on the remote tracking of a 3D optical scanner

    NASA Astrophysics Data System (ADS)

    Barone, Sandro; Paoli, Alessandro; Viviano Razionale, Armando

    2012-03-01

    Full field optical techniques can be reliably used for 3D measurements of complex shapes by multi-view processes, which require the computation of transformation parameters relating different views into a common reference system. Although, several multi-view approaches have been proposed, the alignment process is still the crucial step of a shape reconstruction. In this paper, a methodology to automatically align 3D views has been developed by integrating a stereo vision system and a full field optical scanner. In particular, the stereo vision system is used to remotely track the optical scanner within a working volume. The tracking system uses stereo images to detect the 3D coordinates of retro-reflective infrared markers rigidly connected to the scanner. Stereo correspondences are established by a robust methodology based on combining the epipolar geometry with an image spatial transformation constraint. The proposed methodology has been validated by experimental tests regarding both the evaluation of the measurement accuracy and the 3D reconstruction of an industrial shape.

  10. High-resolution real-time 3D shape measurement on a portable device

    NASA Astrophysics Data System (ADS)

    Karpinsky, Nikolaus; Hoke, Morgan; Chen, Vincent; Zhang, Song

    2013-09-01

    Recent advances in technology have enabled the acquisition of high-resolution 3D models in real-time though the use of structured light scanning techniques. While these advances are impressive, they require large amounts of computing power, thus being limited to using large desktop computers with high end CPUs and sometimes GPUs. This is undesirable in making high-resolution real-time 3D scanners ubiquitous in our mobile lives. To address this issue, this work describes and demonstrates a real-time 3D scanning system that is realized on a mobile device, namely a laptop computer, which can achieve speeds of 20fps 3D at a resolution of 640x480 per frame. By utilizing a graphics processing unit (GPU) as a multipurpose parallel processor, along with a parallel phase shifting technique, we are able to realize the entire 3D processing pipeline in parallel. To mitigate high speed camera transfer problems, which typically require a dedicated frame grabber, we make use of USB 3.0 along with direct memory access (DMA) to transfer camera images to the GPU. To demonstrate the effectiveness of the technique, we experiment with the scanner on both static geometry of a statue and dynamic geometry of a deforming material sample in front of the system.

  11. 3D shape measurements of fast moving rough surfaces by two tilted interference fringe systems

    NASA Astrophysics Data System (ADS)

    Kuschmierz, Robert; Günther, Philipp; Czarske, Jürgen W.

    2013-04-01

    Shape measurement of moving, especially rotating objects is an important task in the field of process control. The Laser Doppler Distance Sensor was invented for this purpose. It is realized by two tilted interference fringe systems and enables the simultaneous measurement of the surface velocity and profile. The distance is coded in the phase difference between the generated interference signals of two photo detectors. In order to achieve a distance uncertainty of below 1μm a steep calibration function is necessary. This can be achieved by increasing the tilting angle. However, due to the speckle effect at rough surfaces, random envelopes and phase jumps occur disturbing the phase difference estimation with increasing tilting angle. This problem was overcome recently by employing a receiving optics matching reducing the distance uncertainty by about one magnitude. By evaluating the Doppler frequencies of the two fringe systems the surface velocity and thereby the objects mean diameter can be calculated as well as angular misalignment of the sensor can be detected.

  12. Evaluation of expansion algorithm of measurement range suited for 3D shape measurement using two pitches of projected grating with light source-stepping method

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Toshimasa; Fujigaki, Motoharu; Murata, Yorinobu

    2015-03-01

    Accurate and wide-range shape measurement method is required in industrial field. The same technique is possible to be used for a shape measurement of a human body for the garment industry. Compact 3D shape measurement equipment is also required for embedding in the inspection system. A shape measurement by a phase shifting method can measure the shape with high spatial resolution because the coordinates can be obtained pixel by pixel. A key-device to develop compact equipment is a grating projector. Authors developed a linear LED projector and proposed a light source stepping method (LSSM) using the linear LED projector. The shape measurement euipment can be produced with low-cost and compact without any phase-shifting mechanical systems by using this method. Also it enables us to measure 3D shape in very short time by switching the light sources quickly. A phase unwrapping method is necessary to widen the measurement range with constant accuracy for phase shifting method. A general phase unwrapping method with difference grating pitches is often used. It is one of a simple phase unwrapping method. It is, however, difficult to apply the conventional phase unwrapping algorithm to the LSSM. Authors, therefore, developed an expansion unwrapping algorithm for the LSSM. In this paper, an expansion algorithm of measurement range suited for 3D shape measurement using two pitches of projected grating with the LSSM was evaluated.

  13. Single-frame digital phase-shifting 3D shape measurement using pixel-wise moiré-wavelength refinement

    NASA Astrophysics Data System (ADS)

    Mohammadi, Fatemeh; Kofman, Jonathan

    2016-03-01

    A novel pixel-wise moiré-wavelength refinement technique was developed for system calibration in single-frame digital phase-shifting 3D shape measurement. The method requires projection of only a single binary grid and capture of a single image frame. Phase-shifted images are generated by digitally phase-shifting a synthetic grid superimposed on the captured frame. The grid patterns are removed from the generated images by wavelet-Fourier transform to extract moiré patterns, from which phase and surface height are computed. A wavelength-height function, computed during system calibration, accounts for moiré-wavelength variation over calibration depth in phase-to-height mapping. Novel pixel-wise wavelength and height (depth) refinement, using this function, improved measurement accuracy compared to measurement using a single global wavelength across all pixels. The method was demonstrated in measurement of a flat plate, hemispherical object, and manikin head.

  14. 3D absolute shape measurement of live rabbit hearts with a superfast two-frequency phase-shifting technique.

    PubMed

    Wang, Yajun; Laughner, Jacob I; Efimov, Igor R; Zhang, Song

    2013-03-11

    This paper presents a two-frequency binary phase-shifting technique to measure three-dimensional (3D) absolute shape of beating rabbit hearts. Due to the low contrast of the cardiac surface, the projector and the camera must remain focused, which poses challenges for any existing binary method where the measurement accuracy is low. To conquer this challenge, this paper proposes to utilize the optimal pulse width modulation (OPWM) technique to generate high-frequency fringe patterns, and the error-diffusion dithering technique to produce low-frequency fringe patterns. Furthermore, this paper will show that fringe patterns produced with blue light provide the best quality measurements compared to fringe patterns generated with red or green light; and the minimum data acquisition speed for high quality measurements is around 800 Hz for a rabbit heart beating at 180 beats per minute. PMID:23482151

  15. 3D shape and eccentricity measurements of fast rotating rough objects by two mutually tilted interference fringe systems

    NASA Astrophysics Data System (ADS)

    Czarske, J. W.; Kuschmierz, R.; Günther, P.

    2013-06-01

    Precise measurements of distance, eccentricity and 3D-shape of fast moving objects such as turning parts of lathes, gear shafts, magnetic bearings, camshafts, crankshafts and rotors of vacuum pumps are on the one hand important tasks. On the other hand they are big challenges, since contactless precise measurement techniques are required. Optical techniques are well suitable for distance measurements of non-moving surfaces. However, measurements of laterally fast moving surfaces are still challenging. For such tasks the laser Doppler distance sensor technique was invented by the TU Dresden some years ago. This technique has been realized by two mutually tilted interference fringe systems, where the distance is coded in the phase difference between the generated interference signals. However, due to the speckle effect different random envelopes and phase jumps of the interference signals occur. They disturb the phase difference estimation between the interference signals. In this paper, we will report on a scientific breakthrough on the measurement uncertainty budget which has been achieved recently. Via matching of the illumination and receiving optics the measurement uncertainty of the displacement and distance can be reduced by about one magnitude. For displacement measurements of a recurring rough surface a standard deviation of 110 nm were attained at lateral velocities of 5 m / s. Due to the additionally measured lateral velocity and the rotational speed, the two-dimensional shape of rotating objects is calculated. The three-dimensional shape can be conducted by employment of a line camera. Since the measurement uncertainty of the displacement, vibration, distance, eccentricity, and shape is nearly independent of the lateral surface velocity, this technique is predestined for fast-rotating objects. Especially it can be advantageously used for the quality control of workpieces inside of a lathe towards the reduction of process tolerances, installation times and

  16. Multi-frequency color-marked fringe projection profilometry for fast 3D shape measurement of complex objects.

    PubMed

    Jiang, Chao; Jia, Shuhai; Dong, Jun; Bao, Qingchen; Yang, Jia; Lian, Qin; Li, Dichen

    2015-09-21

    We propose a novel multi-frequency color-marked fringe projection profilometry approach to measure the 3D shape of objects with depth discontinuities. A digital micromirror device projector is used to project a color map consisting of a series of different-frequency color-marked fringe patterns onto the target object. We use a chromaticity curve to calculate the color change caused by the height of the object. The related algorithm to measure the height is also described in this paper. To improve the measurement accuracy, a chromaticity curve correction method is presented. This correction method greatly reduces the influence of color fluctuations and measurement error on the chromaticity curve and the calculation of the object height. The simulation and experimental results validate the utility of our method. Our method avoids the conventional phase shifting and unwrapping process, as well as the independent calculation of the object height required by existing techniques. Thus, it can be used to measure complex and dynamic objects with depth discontinuities. These advantages are particularly promising for industrial applications. PMID:26406621

  17. Micrometer-scale 3-D shape characterization of eight cements: Particle shape and cement chemistry, and the effect of particle shape on laser diffraction particle size measurement

    SciTech Connect

    Erdogan, S.T.; Nie, X.; Stutzman, P.E.; Garboczi, E.J.

    2010-05-15

    Eight different portland cements were imaged on a synchrotron beam line at Brookhaven National Laboratory using X-ray microcomputed tomography at a voxel size of about 1 mum per cubic voxel edge. The particles ranged in size roughly between 10 mum and 100 mum. The shape and size of individual particles were computationally analyzed using spherical harmonic analysis. The particle shape difference between cements was small but significant, as judged by several different quantitative shape measures, including the particle length, width, and thickness distributions. It was found that the average shape of cement particles was closely correlated with the volume fraction of C{sub 3}S (alite) and C{sub 2}S (belite) making up the cement powder. It is shown that the non-spherical particle shape of the cements strongly influence laser diffraction results, at least in the sieve size range of 20 mum to 38 mum. Since laser diffraction particle size measurement is being increasingly used by the cement industry, while cement chemistry is always a main factor in cement production, these results could have important implications for how this kind of particle size measurement should be understood and used in the cement industry.

  18. 3D shape decomposition and comparison for gallbladder modeling

    NASA Astrophysics Data System (ADS)

    Huang, Weimin; Zhou, Jiayin; Liu, Jiang; Zhang, Jing; Yang, Tao; Su, Yi; Law, Gim Han; Chui, Chee Kong; Chang, Stephen

    2011-03-01

    This paper presents an approach to gallbladder shape comparison by using 3D shape modeling and decomposition. The gallbladder models can be used for shape anomaly analysis and model comparison and selection in image guided robotic surgical training, especially for laparoscopic cholecystectomy simulation. The 3D shape of a gallbladder is first represented as a surface model, reconstructed from the contours segmented in CT data by a scheme of propagation based voxel learning and classification. To better extract the shape feature, the surface mesh is further down-sampled by a decimation filter and smoothed by a Taubin algorithm, followed by applying an advancing front algorithm to further enhance the regularity of the mesh. Multi-scale curvatures are then computed on the regularized mesh for the robust saliency landmark localization on the surface. The shape decomposition is proposed based on the saliency landmarks and the concavity, measured by the distance from the surface point to the convex hull. With a given tolerance the 3D shape can be decomposed and represented as 3D ellipsoids, which reveal the shape topology and anomaly of a gallbladder. The features based on the decomposed shape model are proposed for gallbladder shape comparison, which can be used for new model selection. We have collected 19 sets of abdominal CT scan data with gallbladders, some shown in normal shape and some in abnormal shapes. The experiments have shown that the decomposed shapes reveal important topology features.

  19. Shape corrections for 3D EIT

    NASA Astrophysics Data System (ADS)

    Paridis, Kyriakos; Lionheart, William R. B.

    2010-04-01

    Movement of the boundary in biomedical Electrical Impedance Tomography (EIT) has been always a source of error in image reconstruction. In the case of pulmonary EIT, where the patient's chest shape changes during respiration, this is inevitable, so it is essential to be able to correct for shape changes and consequently avoid artifacts. Assuming that the conductivity is isotropic, an assumption that is reasonable for lung tissue but admittedly violated for muscle, the boundary shape up to a Möbius transformation (conformal mapping) as well as the conductivity can theoretically be determined by 3D EIT data. While in two dimensions the space of conformal mappings are infinite dimensional, in the three dimensional case the Möbius transformations are given by a finite number of parameters. In this paper, we concentrate on the three dimensional case and take a linear approximation. We will give results of numerical studies analogous to the two dimensional work of Boyle et al on the effect of electrode movement and shape error in 3D EIT.

  20. Optimized design of a LED-array-based TOF range imaging sensor for fast 3-D shape measurement

    NASA Astrophysics Data System (ADS)

    Wang, Huanqin; Wang, Ying; Xu, Jun; He, Deyong; Zhao, Tianpeng; Ming, Hai; Kong, Deyi

    2011-06-01

    A LED-array-based range imaging sensor using Time-of-Flight (TOF) distance measurement was developed to capture the depth information of three-dimensional (3-D) object. By time-division electronic scanning of the LED heterodyne phase-shift TOF range finders in array, the range images were fast obtained without any mechanical moving parts. The design of LED-array-based range imaging sensor was adequately described and a range imaging theoretical model based on photoelectric signal processing was built, which showed there was mutual restriction relationship among the measurement time of a depth pixel, the bandwidth of receiver and the sensor's signal-to-noise ratio (SNR). In order to improve the key parameters of sensor such as range resolution and measurement speed simultaneously, some optimized designs needed to be done for the proposed range imaging sensor, including choosing proper parameters for the filters in receiver, adopting special structure feedback automatic gain control (AGC) circuit with short response time, etc. The final experiment results showed the sensor after optimization could acquire the range images at a rate of 10 frames per second with a range resolution as high as +/-2mm in the range of 50-1200mm. The essential advantages of the proposed range imaging sensor were construction with simple structure, high range resolution, short measurement time and low cost, which was sufficient for many robotic and industrial automation applications.

  1. Measured symmetry of facial 3D shape and perceived facial symmetry and attractiveness before and after orthognathic surgery.

    PubMed

    Ostwald, Julia; Berssenbrügge, Philipp; Dirksen, Dieter; Runte, Christoph; Wermker, Kai; Kleinheinz, Johannes; Jung, Susanne

    2015-05-01

    One aim of cranio-maxillo-facial surgery is to strive for an esthetical appearance. Do facial symmetry and attractiveness correlate? How are they affected by surgery? Within this study faces of patients with orthognathic surgery were captured and analyzed regarding their symmetry. A total of 25 faces of patients were measured three-dimensionally by an optical sensor using the fringe projection technique before and after orthognathic surgery. Based upon this data an asymmetry index was calculated for each case. In order to gather subjective ratings each face was presented to 100 independent test subjects in a 3D rotation sequence. Those were asked to rate the symmetry and the attractiveness of the faces. It was analyzed to what extend the ratings correlate with the measured asymmetry indices and whether pre- and post-surgical data differ. The measured asymmetry indices correlate significantly with the subjective ratings of both items. The measured symmetry as well as the rated symmetry and attractiveness increased on average after surgery. The increase of the ratings was even statistically significant. A larger enhancement of symmetry is achieved in pre-surgical strongly asymmetric faces than in rather symmetric faces. PMID:25841308

  2. Understanding 3D human torso shape via manifold clustering

    NASA Astrophysics Data System (ADS)

    Li, Sheng; Li, Peng; Fu, Yun

    2013-05-01

    Discovering the variations in human torso shape plays a key role in many design-oriented applications, such as suit designing. With recent advances in 3D surface imaging technologies, people can obtain 3D human torso data that provide more information than traditional measurements. However, how to find different human shapes from 3D torso data is still an open problem. In this paper, we propose to use spectral clustering approach on torso manifold to address this problem. We first represent high-dimensional torso data in a low-dimensional space using manifold learning algorithm. Then the spectral clustering method is performed to get several disjoint clusters. Experimental results show that the clusters discovered by our approach can describe the discrepancies in both genders and human shapes, and our approach achieves better performance than the compared clustering method.

  3. Alpha shape theory for 3D visualization and volumetric measurement of brain tumor progression using magnetic resonance images.

    PubMed

    Hamoud Al-Tamimi, Mohammed Sabbih; Sulong, Ghazali; Shuaib, Ibrahim Lutfi

    2015-07-01

    Resection of brain tumors is a tricky task in surgery due to its direct influence on the patients' survival rate. Determining the tumor resection extent for its complete information via-à-vis volume and dimensions in pre- and post-operative Magnetic Resonance Images (MRI) requires accurate estimation and comparison. The active contour segmentation technique is used to segment brain tumors on pre-operative MR images using self-developed software. Tumor volume is acquired from its contours via alpha shape theory. The graphical user interface is developed for rendering, visualizing and estimating the volume of a brain tumor. Internet Brain Segmentation Repository dataset (IBSR) is employed to analyze and determine the repeatability and reproducibility of tumor volume. Accuracy of the method is validated by comparing the estimated volume using the proposed method with that of gold-standard. Segmentation by active contour technique is found to be capable of detecting the brain tumor boundaries. Furthermore, the volume description and visualization enable an interactive examination of tumor tissue and its surrounding. Admirable features of our results demonstrate that alpha shape theory in comparison to other existing standard methods is superior for precise volumetric measurement of tumor. PMID:25865822

  4. Improved differential 3D shape retrieval

    NASA Astrophysics Data System (ADS)

    Liu, Tongchuan; Zhou, Canlin; Si, Shuchun; Li, Hui; Lei, Zhenkun

    2015-10-01

    Phase unwrapping is a complex step in three-dimensional (3D) surface measurement. To simplify the computation process, Martino et al. proposed a differential algorithm. However, it will result in large error when the orthogonal fringes are not in horizontal or vertical direction. To solve this problem, the relationship between projector's and camera's coordinate systems is introduced. With the data obtained from coordinate transformation, the improved differential algorithm can be used for orthogonal fringes in any direction. Besides that, taking advantage of Fourier differentiation theorem makes operation and calculation simpler. By contrast, the results of experiments show that the proposed method is applicable to the patterns with orthogonal fringes in every direction. In addition, Fourier differentiation theorem effectively increases the speed of differential process.

  5. A 3-D shape model of Interamnia

    NASA Astrophysics Data System (ADS)

    Sato, Isao

    2015-08-01

    A 3-D shape model of the sixth largest of the main belt asteroids, (704) Interamnia, is presented. The model is reproduced from its two stellar occultation observations and six lightcurves between 1969 and 2011. The first stellar occultation was the occultation of TYC 234500183 on 1996 December 17 observed from 13 sites in the USA. An elliptical cross section of (344.6±9.6km)×(306.2±9.1km), for position angle P=73.4±12.5 was fitted. The lightcurve around the occultation shows that the peak-to-peak amplitude was 0.04 mag. and the occultation phase was just before the minimum. The second stellar occultation was the occultation of HIP 036189 on 2003 March 23 observed from 39 sites in Japan and Hawaii. An elliptical cross section of (349.8±0.9km)×(303.7±1.7km), for position angle P=86.0±1.1 was fitted. A companion of 8.5 mag. of the occulted star was discovered whose separation is 12±2 mas (milli-arcseconds), P=148±11 . A combined analysis of rotational lightcurves and occultation chords can return more information than can be obtained with either technique alone. From follow-up photometric observations of the asteroid between 2003 and 2011, its rotation period is determined to be 8.728967167±0.00000007 hours, which is accurate enough to fix the rotation phases at other occultation events. The derived north pole is λ2000=259±8, β2000=-50±5 (retrograde rotation); the lengths of the three principal axes are 2a=361.8±2.8km, 2b=324.4±5.0km, 2c=297.3±3.5km, and the mean diameter is D=326.8±3.0km. Supposing the mass of Interamnia as (3.5±0.9)×10-11 solar masses, the density is then ρ=3.8±1.0 g cm-3.

  6. Phase unwrapping in the dynamic 3D measurement

    NASA Astrophysics Data System (ADS)

    Su, Xianyu; Zhang, Qican

    2010-04-01

    In the dynamic 3D shape measurement phase distribution has 3D character, in which phase changes along x and y directions in space and also along t direction in time. 3D phase unwrapping plays a very important role in the dynamic 3D shape measurement. In the dynamic 3D shape measurement methods based on the structured illumination, Fourier transformation profilometry (FTP) is particularly fit for dynamic 3D measurement, because of only one fringe pattern needed and full field analysis. In this paper some 3D phase unwrapping techniques for dynamic 3D shape measurement mainly in our Lab. are presented and reviewed. The basic methods and algorithm design are introduced. The basic methods include direct 3D phase unwrapping, 3D diamond phase unwrapping, 3D phase unwrapping based on reliability ordering, 3D phase unwrapping based on marked fringe tracing. The advantage of the phase unwrapping based on reliability ordering is that the path of phase unwrapping is always along the direction from the pixel with higher reliability parameter value to the pixel with low reliability parameter value. Therefore, in the worse case the error is limited, if there is any, to local minimum areas.

  7. Towards automated firearm identification based on high resolution 3D data: rotation-invariant features for multiple line-profile-measurement of firing pin shapes

    NASA Astrophysics Data System (ADS)

    Fischer, Robert; Vielhauer, Claus

    2015-03-01

    Understanding and evaluation of potential evidence, as well as evaluation of automated systems for forensic examinations currently play an important role within the domain of digital crime scene analysis. The application of 3D sensing and pattern recognition systems for automatic extraction and comparison of firearm related tool marks is an evolving field of research within this domain. In this context, the design and evaluation of rotation-invariant features for use on topography data play a particular important role. In this work, we propose and evaluate a 3D imaging system along with two novel features based on topography data and multiple profile-measurement-lines for automatic matching of firing pin shapes. Our test set contains 72 cartridges of three manufactures shot by six different 9mm guns. The entire pattern recognition workflow is addressed. This includes the application of confocal microscopy for data acquisition, preprocessing covers outlier handling, data normalization, as well as necessary segmentation and registration. Feature extraction involves the two introduced features for automatic comparison and matching of 3D firing pin shapes. The introduced features are called `Multiple-Circle-Path' (MCP) and `Multiple-Angle-Path' (MAP). Basically both features are compositions of freely configurable amounts of circular or straight path-lines combined with statistical evaluations. During the first part of evaluation (E1), we examine how well it is possible to differentiate between two 9mm weapons of the same mark and model. During second part (E2), we evaluate the discrimination accuracy regarding the set of six different 9mm guns. During the third part (E3), we evaluate the performance of the features in consideration of different rotation angles. In terms of E1, the best correct classification rate is 100% and in terms of E2 the best result is 86%. The preliminary results for E3 indicate robustness of both features regarding rotation. However, in future

  8. Temperature dependences of self- and N2-broadened line-shape parameters in the ν3 and ν5 bands of 12CH3D: Measurements and calculations

    NASA Astrophysics Data System (ADS)

    Predoi-Cross, A.; Malathy Devi, V.; Sutradhar, P.; Sinyakova, T.; Buldyreva, J.; Sung, K.; Smith, M. A. H.; Mantz, A. W.

    2016-07-01

    This paper presents the results of a spectroscopic line shape study of self- and nitrogen-broadened 12CH3D transitions in the ν3 and ν5 bands in the Triad region. We combined five pure gas spectra with eighteen spectra of lean mixtures of 12CH3D and nitrogen, all recorded with a Bruker IFS-125 HR Fourier transform spectrometer. The spectra have been analyzed simultaneously using a multispectrum nonlinear least squares fitting technique. N2-broadened line parameters for 184 transitions in the ν3 band and 205 transitions in the ν5 band were measured. In addition, line positions and line intensities were measured for 168 transitions in the ν3 band and 214 transitions in the ν5 band. We have observed 10 instances of weak line mixing corresponding to K″=3 A1 or A2 transitions. Comparisons were made for the N2-broadening coefficients and associated temperature exponents with corresponding values calculated using a semi-classical Robert Bonamy type formalism that involved an inter-molecular potential with terms corresponding to short- and long-range interactions, and exact classical molecular trajectories. The theoretical N2-broadened coefficients are overestimated for high J values, but are in good agreement with the experimental values for small and middle range J values.

  9. 3D bicipital groove shape analysis and relationship to tendopathy.

    PubMed

    Ward, Aaron D; Hamarneh, Ghassan; Schweitzer, Mark E

    2008-06-01

    The bicipital groove of the proximal humerus is formed by the medial and lateral tuberosities and serves to retain the long biceps tendon in its proper place as the arm moves. Bicipital root and proximal tendon disorders are an important symptom generator in the shoulder. The accuracy of the diagnosis of many shoulder disorders visually without quantitative shape analysis is limited, motivating a clinical need for some ancillary method to assess the proximal biceps. In previous studies, measurements of bicipital groove shape were 2-dimensional (2D), taken from a single axial slice. Because of significant variations in groove shape from one axial slice to another in a single patient, such approaches risk overlooking shape features important to long biceps tendon pathology. In this paper, we present a study of the relationship between bicipital groove shape and long biceps tendon pathology using a novel 3-dimensional (3D) shape descriptor for the bicipital groove. In addition to providing quantitative measures of the shape of the groove and its relation to tendopathy, the new descriptor allows for intuitive, descriptive visualization of the shape of the groove. PMID:17342555

  10. Aesthetic preference recognition of 3D shapes using EEG.

    PubMed

    Chew, Lin Hou; Teo, Jason; Mountstephens, James

    2016-04-01

    Recognition and identification of aesthetic preference is indispensable in industrial design. Humans tend to pursue products with aesthetic values and make buying decisions based on their aesthetic preferences. The existence of neuromarketing is to understand consumer responses toward marketing stimuli by using imaging techniques and recognition of physiological parameters. Numerous studies have been done to understand the relationship between human, art and aesthetics. In this paper, we present a novel preference-based measurement of user aesthetics using electroencephalogram (EEG) signals for virtual 3D shapes with motion. The 3D shapes are designed to appear like bracelets, which is generated by using the Gielis superformula. EEG signals were collected by using a medical grade device, the B-Alert X10 from advance brain monitoring, with a sampling frequency of 256 Hz and resolution of 16 bits. The signals obtained when viewing 3D bracelet shapes were decomposed into alpha, beta, theta, gamma and delta rhythm by using time-frequency analysis, then classified into two classes, namely like and dislike by using support vector machines and K-nearest neighbors (KNN) classifiers respectively. Classification accuracy of up to 80 % was obtained by using KNN with the alpha, theta and delta rhythms as the features extracted from frontal channels, Fz, F3 and F4 to classify two classes, like and dislike. PMID:27066153

  11. 3D-Geomorphometrics tooth shape analysis in hypodontia

    PubMed Central

    Al-Shahrani, Ibrahim; Dirks, Wendy; Jepson, Nicholas; Khalaf, Khaled

    2014-01-01

    Assessment of tooth morphology is an important part of the diagnosis and management of hypodontia patients. Several techniques have been used to analyze tooth form in hypodontia patients and these have shown smaller tooth dimensions and anomalous tooth shapes in patients with hypodontia when compared with controls. However, previous studies have mainly used 2D images and provided limited information. In the present study, 3D surface-imaging and statistical shape analysis were used to evaluate tooth form differences between hypodontia and control patients. Eighteen anatomical landmarks were recorded on the clinical crown of the lower left first permanent molar of 3D scanned study models of hypodontia and control subjects. The study sample group comprised of 120 hypodontia patients (40 mild, 40 moderate, and 40 severe hypodontia patients) and 40 age- and sex-matched controls. Procrustes coordinates were utilized to scale and superimpose the landmark coordinate data and then were subjected to principal component analysis (PCA). Subsequently, differences in shape as well as size were tested statistically using allometric analysis and MANOVA. Significant interaction was found between the two factor variables “group” and “sex” (p < 0.002). Overall expected accuracies were 66 and 56% for females and males, respectively, in the cross-validated discriminant-analysis using the first 20 PCs. Hypodontia groups showed significant shape differences compared with the control subjects (p < 0.0001). Significant differences in tooth crown shape were also found between sexes (p < 0.0001) within groups. Furthermore, the degree of variation in tooth form was proportional to the degree of the severity of the hypodontia. Thus, quantitative measurement of tooth shape in hypodontia patients may enhance the multidisciplinary management of those patients. PMID:24795649

  12. Automatic 3-D grayscale volume matching and shape analysis.

    PubMed

    Guétat, Grégoire; Maitre, Matthieu; Joly, Laurène; Lai, Sen-Lin; Lee, Tzumin; Shinagawa, Yoshihisa

    2006-04-01

    Recently, shape matching in three dimensions (3-D) has been gaining importance in a wide variety of fields such as computer graphics, computer vision, medicine, and biology, with applications such as object recognition, medical diagnosis, and quantitative morphological analysis of biological operations. Automatic shape matching techniques developed in the field of computer graphics handle object surfaces, but ignore intensities of inner voxels. In biology and medical imaging, voxel intensities obtained by computed tomography (CT), magnetic resonance imagery (MRI), and confocal microscopes are important to determine point correspondences. Nevertheless, most biomedical volume matching techniques require human interactions, and automatic methods assume matched objects to have very similar shapes so as to avoid combinatorial explosions of point. This article is aimed at decreasing the gap between the two fields. The proposed method automatically finds dense point correspondences between two grayscale volumes; i.e., finds a correspondent in the second volume for every voxel in the first volume, based on the voxel intensities. Mutiresolutional pyramids are introduced to reduce computational load and handle highly plastic objects. We calculate the average shape of a set of similar objects and give a measure of plasticity to compare them. Matching results can also be used to generate intermediate volumes for morphing. We use various data to validate the effectiveness of our method: we calculate the average shape and plasticity of a set of fly brain cells, and we also match a human skull and an orangutan skull. PMID:16617625

  13. An efficient memetic algorithm for 3D shape matching problems

    NASA Astrophysics Data System (ADS)

    Sharif Khan, Mohammad; Mohamad Ayob, Ahmad F.; Ray, Tapabrata

    2014-05-01

    Shape representation plays a vital role in any shape optimization exercise. The ability to identify a shape with good functional properties is dependent on the underlying shape representation scheme, the morphing mechanism and the efficiency of the optimization algorithm. This article presents a novel and efficient methodology for morphing 3D shapes via smart repair of control points. The repaired sequence of control points are subsequently used to define the 3D object using a B-spline surface representation. The control points are evolved within the framework of a memetic algorithm for greater efficiency. While the authors have already proposed an approach for 2D shape matching, this article extends it further to deal with 3D shape matching problems. Three 3D examples and a real customized 3D earplug design have been used as examples to illustrate the performance of the proposed approach and the effectiveness of the repair scheme. Complete details of the problems are presented for future work in this direction.

  14. Perception-based shape retrieval for 3D building models

    NASA Astrophysics Data System (ADS)

    Zhang, Man; Zhang, Liqiang; Takis Mathiopoulos, P.; Ding, Yusi; Wang, Hao

    2013-01-01

    With the help of 3D search engines, a large number of 3D building models can be retrieved freely online. A serious disadvantage of most rotation-insensitive shape descriptors is their inability to distinguish between two 3D building models which are different at their main axes, but appear similar when one of them is rotated. To resolve this problem, we present a novel upright-based normalization method which not only correctly rotates such building models, but also greatly simplifies and accelerates the abstraction and the matching of building models' shape descriptors. Moreover, the abundance of architectural styles significantly hinders the effective shape retrieval of building models. Our research has shown that buildings with different designs are not well distinguished by the widely recognized shape descriptors for general 3D models. Motivated by this observation and to further improve the shape retrieval quality, a new building matching method is introduced and analyzed based on concepts found in the field of perception theory and the well-known Light Field descriptor. The resulting normalized building models are first classified using the qualitative shape descriptors of Shell and Unevenness which outline integral geometrical and topological information. These models are then put in on orderly fashion with the help of an improved quantitative shape descriptor which we will term as Horizontal Light Field Descriptor, since it assembles detailed shape characteristics. To accurately evaluate the proposed methodology, an enlarged building shape database which extends previous well-known shape benchmarks was implemented as well as a model retrieval system supporting inputs from 2D sketches and 3D models. Various experimental performance evaluation results have shown that, as compared to previous methods, retrievals employing the proposed matching methodology are faster and more consistent with human recognition of spatial objects. In addition these performance

  15. Optofluidic fabrication for 3D-shaped particles.

    PubMed

    Paulsen, Kevin S; Di Carlo, Dino; Chung, Aram J

    2015-01-01

    Complex three-dimensional (3D)-shaped particles could play unique roles in biotechnology, structural mechanics and self-assembly. Current methods of fabricating 3D-shaped particles such as 3D printing, injection moulding or photolithography are limited because of low-resolution, low-throughput or complicated/expensive procedures. Here, we present a novel method called optofluidic fabrication for the generation of complex 3D-shaped polymer particles based on two coupled processes: inertial flow shaping and ultraviolet (UV) light polymerization. Pillars within fluidic platforms are used to deterministically deform photosensitive precursor fluid streams. The channels are then illuminated with patterned UV light to polymerize the photosensitive fluid, creating particles with multi-scale 3D geometries. The fundamental advantages of optofluidic fabrication include high-resolution, multi-scalability, dynamic tunability, simple operation and great potential for bulk fabrication with full automation. Through different combinations of pillar configurations, flow rates and UV light patterns, an infinite set of 3D-shaped particles is available, and a variety are demonstrated. PMID:25904062

  16. Optofluidic fabrication for 3D-shaped particles

    NASA Astrophysics Data System (ADS)

    Paulsen, Kevin S.; di Carlo, Dino; Chung, Aram J.

    2015-04-01

    Complex three-dimensional (3D)-shaped particles could play unique roles in biotechnology, structural mechanics and self-assembly. Current methods of fabricating 3D-shaped particles such as 3D printing, injection moulding or photolithography are limited because of low-resolution, low-throughput or complicated/expensive procedures. Here, we present a novel method called optofluidic fabrication for the generation of complex 3D-shaped polymer particles based on two coupled processes: inertial flow shaping and ultraviolet (UV) light polymerization. Pillars within fluidic platforms are used to deterministically deform photosensitive precursor fluid streams. The channels are then illuminated with patterned UV light to polymerize the photosensitive fluid, creating particles with multi-scale 3D geometries. The fundamental advantages of optofluidic fabrication include high-resolution, multi-scalability, dynamic tunability, simple operation and great potential for bulk fabrication with full automation. Through different combinations of pillar configurations, flow rates and UV light patterns, an infinite set of 3D-shaped particles is available, and a variety are demonstrated.

  17. Automatic Reconstruction of Spacecraft 3D Shape from Imagery

    NASA Astrophysics Data System (ADS)

    Poelman, C.; Radtke, R.; Voorhees, H.

    We describe a system that computes the three-dimensional (3D) shape of a spacecraft from a sequence of uncalibrated, two-dimensional images. While the mathematics of multi-view geometry is well understood, building a system that accurately recovers 3D shape from real imagery remains an art. A novel aspect of our approach is the combination of algorithms from computer vision, photogrammetry, and computer graphics. We demonstrate our system by computing spacecraft models from imagery taken by the Air Force Research Laboratory's XSS-10 satellite and DARPA's Orbital Express satellite. Using feature tie points (each identified in two or more images), we compute the relative motion of each frame and the 3D location of each feature using iterative linear factorization followed by non-linear bundle adjustment. The "point cloud" that results from this traditional shape-from-motion approach is typically too sparse to generate a detailed 3D model. Therefore, we use the computed motion solution as input to a volumetric silhouette-carving algorithm, which constructs a solid 3D model based on viewpoint consistency with the image frames. The resulting voxel model is then converted to a facet-based surface representation and is texture-mapped, yielding realistic images from arbitrary viewpoints. We also illustrate other applications of the algorithm, including 3D mensuration and stereoscopic 3D movie generation.

  18. Conveying the 3D Shape of Transparent Surfaces Via Texture

    NASA Technical Reports Server (NTRS)

    Interrante, Victoria; Fuchs, Henry; Pizer, Stephen

    1997-01-01

    Transparency can be a useful device for depicting multiple overlapping surfaces in a single image. The challenge is to render the transparent surfaces in such a way that their three-dimensional shape can be readily understood and their depth distance from underlying structures clearly perceived. This paper describes our investigations into the use of sparsely-distributed discrete, opaque texture as an 'artistic device' for more explicitly indicating the relative depth of a transparent surface and for communicating the essential features of its 3D shape in an intuitively meaningful and minimally occluding way. The driving application for this work is the visualization of layered surfaces in radiation therapy treatment planning data, and the technique is illustrated on transparent isointensity surfaces of radiation dose. We describe the perceptual motivation and artistic inspiration for defining a stroke texture that is locally oriented in the direction of greatest normal curvature (and in which individual strokes are of a length proportional to the magnitude of the curvature in the direction they indicate), and discuss several alternative methods for applying this texture to isointensity surfaces defined in a volume. We propose an experimental paradigm for objectively measuring observers' ability to judge the shape and depth of a layered transparent surface, in the course of a task relevant to the needs of radiotherapy treatment planning, and use this paradigm to evaluate the practical effectiveness of our approach through a controlled observer experiment based on images generated from actual clinical data.

  19. Light shaping along 3D curves and particle manipulation

    NASA Astrophysics Data System (ADS)

    Rodrigo, José A.; Alieva, Tatiana

    2015-03-01

    We present a non-iterative holographic technique for efficient and versatile laser beam shaping along arbitrary 3D curves. Light beams with intensity shaped for several 3D curves: Tilted ring, Viviani's curve, Archimedean spiral, and trefoil-knotted curve have been experimentally generated and applied for optical trapping of micrometer-sized dielectric particles. The high intensity gradients and independent phase control prescribed along the curve make this kind of laser trap attractive for multiple particle manipulation and allow for forward and backward motion to the light source. Indeed, different configurations of tractor beam traps are experimentally demonstrated. This technique can also be applied for laser micro-machining.

  20. Dynamic 3D Visualization of Vocal Tract Shaping During Speech

    PubMed Central

    Zhu, Yinghua; Kim, Yoon-Chul; Proctor, Michael I.; Narayanan, Shrikanth S.; Nayak, Krishna S.

    2014-01-01

    Noninvasive imaging is widely used in speech research as a means to investigate the shaping and dynamics of the vocal tract during speech production. 3D dynamic MRI would be a major advance, as it would provide 3D dynamic visualization of the entire vocal tract. We present a novel method for the creation of 3D dynamic movies of vocal tract shaping based on the acquisition of 2D dynamic data from parallel slices and temporal alignment of the image sequences using audio information. Multiple sagittal 2D real-time movies with synchronized audio recordings are acquired for English vowel-consonant-vowel stimuli /ala/, /aɹa/, /asa/ and /aʃa/. Audio data are aligned using mel-frequency cepstral coefficients (MFCC) extracted from windowed intervals of the speech signal. Sagittal image sequences acquired from all slices are then aligned using dynamic time warping (DTW). The aligned image sequences enable dynamic 3D visualization by creating synthesized movies of the moving airway in the coronal planes, visualizing desired tissue surfaces and tube-shaped vocal tract airway after manual segmentation of targeted articulators and smoothing. The resulting volumes allow for dynamic 3D visualization of salient aspects of lingual articulation, including the formation of tongue grooves and sublingual cavities, with a temporal resolution of 78 ms. PMID:23204279

  1. Shape control in wafer-based aperiodic 3D nanostructures

    NASA Astrophysics Data System (ADS)

    Jeong, Hyeon-Ho; Mark, Andrew G.; Gibbs, John G.; Reindl, Thomas; Waizmann, Ulrike; Weis, Jürgen; Fischer, Peer

    2014-06-01

    Controlled local fabrication of three-dimensional (3D) nanostructures is important to explore and enhance the function of single nanodevices, but is experimentally challenging. We present a scheme based on e-beam lithography (EBL) written seeds, and glancing angle deposition (GLAD) grown structures to create nanoscale objects with defined shapes but in aperiodic arrangements. By using a continuous sacrificial corral surrounding the features of interest we grow isolated 3D nanostructures that have complex cross-sections and sidewall morphology that are surrounded by zones of clean substrate.

  2. 3D optical measuring technologies and systems

    NASA Astrophysics Data System (ADS)

    Chugui, Yuri V.

    2005-02-01

    The results of the R & D activity of TDI SIE SB RAS in the field of the 3D optical measuring technologies and systems for noncontact 3D optical dimensional inspection applied to atomic and railway industry safety problems are presented. This activity includes investigations of diffraction phenomena on some 3D objects, using the original constructive calculation method. The efficient algorithms for precise determining the transverse and longitudinal sizes of 3D objects of constant thickness by diffraction method, peculiarities on formation of the shadow and images of the typical elements of the extended objects were suggested. Ensuring the safety of nuclear reactors and running trains as well as their high exploitation reliability requires a 100% noncontact precise inspection of geometrical parameters of their components. To solve this problem we have developed methods and produced the technical vision measuring systems LMM, CONTROL, PROFIL, and technologies for noncontact 3D dimensional inspection of grid spacers and fuel elements for the nuclear reactor VVER-1000 and VVER-440, as well as automatic laser diagnostic COMPLEX for noncontact inspection of geometric parameters of running freight car wheel pairs. The performances of these systems and the results of industrial testing are presented and discussed. The created devices are in pilot operation at Atomic and Railway Companies.

  3. The 3D Shape of the Dendrite by WDT Method

    NASA Astrophysics Data System (ADS)

    Tang, Chao; Mitobe, Kazutaka; Yoshimura, Noboru

    The purpose of this study is use of a three dimension (3D) measuring system that can automatically measure surface condition. We applied the WDT method that is one of the migration acceleration testing methods, to calculate the spatial variation of the electrodes of ion immigration on a glass epoxy printed wiring board. We also investigated the spatial shape and its variation of dendrite after short circuit for the cases of uniform and nonuniform field strength. As a result the phenomenon of immigration peak of separated matter from cathode to anode due to nonuniform was reported.The moving of the peak of the separated matter is supposed to be due to Cu(OH)2's change in accumulation status. Under the nonuniform and uniform situation, the behavior of separated matter will change after occurring short circuit between the electrodes. Therefore in order to avoid the progress of ion immigration, it is necessary to pay attention to the field strength in hardwiring and the curvature so that the field strength of the wiring pattern cannot be very high.

  4. A Modified Exoskeleton for 3D Shape Description and Recognition

    NASA Astrophysics Data System (ADS)

    Lipikorn, Rajalida; Shimizu, Akinobu; Hagihara, Yoshihiro; Kobatake, Hidefumi

    Three-dimensional(3D) shape representation is a powerful tool in object recognition that is an essential process in an image processing and analysis system. Skeleton is one of the most widely used representations for object recognition, nevertheless most of the skeletons obtained from conventional methods are susceptible to rotation and noise disturbances. In this paper, we present a new 3D object representation called a modified exoskeleton (mES) which preserves skeleton properties including significant characteristics about an object that are meaningful for object recognition, and is more stable and less susceptible to rotation and noise than the skeletons. Then a 3D shape recognition methodology which determines the similarity between an observed object and other known objects in a database is introduced. Through a number of experiments on 3D artificial objects and real volumetric lung tumors extracted from CT images, it can be verified that our proposed methodology based on the mES is a simple yet efficient method that is less sensitive to rotation, noise, and independent of orientation and size of the objects.

  5. A novel orthogonal transmission-virtual grating method and its applications in measuring micro 3-D shape of deformed liquid surface

    NASA Astrophysics Data System (ADS)

    Liu, Zhanwei; Huang, Xianfu; Xie, Huimin

    2013-02-01

    Deformed liquid surface directly involves the surface tension, which can always be used to account for the kinematics of aquatic insects in gas-liquid interface and the light metal floating on the water surface. In this paper a novel method based upon deformed transmission-virtual grating is proposed for determination of deformed liquid surface. By addressing an orthogonal grating (1-5 line/mm) under the transparent water groove and then capturing images from upset of the deformed water surface, a displacement vector of full-field which directly associates the 3-D deformed liquid surface then can be evaluated by processing the recorded deformed fringe pattern in the two directions (x- and y-direction). Theories and equations for the method are thoroughly delivered. Validation test to measure the deformed water surface caused by a Chinese 1-cent coin has been conducted to demonstrate the ability of the developed method. The obtained results show that the method is robust in determination of micro 3-D surface of deformed liquid with a submicron scale resolution and with a wide range application scope.

  6. 3D measurement using circular gratings

    NASA Astrophysics Data System (ADS)

    Harding, Kevin

    2013-09-01

    3D measurement using methods of structured light are well known in the industry. Most such systems use some variation of straight lines, either as simple lines or with some form of encoding. This geometry assumes the lines will be projected from one side and viewed from another to generate the profile information. But what about applications where a wide triangulation angle may not be practical, particularly at longer standoff distances. This paper explores the use of circular grating patterns projected from a center point to achieve 3D information. Originally suggested by John Caulfield around 1990, the method had some interesting potential, particularly if combined with alternate means of measurement from traditional triangulation including depth from focus methods. The possible advantages of a central reference point in the projected pattern may offer some different capabilities not as easily attained with a linear grating pattern. This paper will explore the pros and cons of the method and present some examples of possible applications.

  7. A spherical harmonics intensity model for 3D segmentation and 3D shape analysis of heterochromatin foci.

    PubMed

    Eck, Simon; Wörz, Stefan; Müller-Ott, Katharina; Hahn, Matthias; Biesdorf, Andreas; Schotta, Gunnar; Rippe, Karsten; Rohr, Karl

    2016-08-01

    The genome is partitioned into regions of euchromatin and heterochromatin. The organization of heterochromatin is important for the regulation of cellular processes such as chromosome segregation and gene silencing, and their misregulation is linked to cancer and other diseases. We present a model-based approach for automatic 3D segmentation and 3D shape analysis of heterochromatin foci from 3D confocal light microscopy images. Our approach employs a novel 3D intensity model based on spherical harmonics, which analytically describes the shape and intensities of the foci. The model parameters are determined by fitting the model to the image intensities using least-squares minimization. To characterize the 3D shape of the foci, we exploit the computed spherical harmonics coefficients and determine a shape descriptor. We applied our approach to 3D synthetic image data as well as real 3D static and real 3D time-lapse microscopy images, and compared the performance with that of previous approaches. It turned out that our approach yields accurate 3D segmentation results and performs better than previous approaches. We also show that our approach can be used for quantifying 3D shape differences of heterochromatin foci. PMID:27037463

  8. 3D Shape and Indirect Appearance by Structured Light Transport.

    PubMed

    OToole, Matthew; Mather, John; Kutulakos, Kiriakos N

    2016-07-01

    We consider the problem of deliberately manipulating the direct and indirect light flowing through a time-varying, general scene in order to simplify its visual analysis. Our approach rests on a crucial link between stereo geometry and light transport: while direct light always obeys the epipolar geometry of a projector-camera pair, indirect light overwhelmingly does not. We show that it is possible to turn this observation into an imaging method that analyzes light transport in real time in the optical domain, prior to acquisition. This yields three key abilities that we demonstrate in an experimental camera prototype: (1) producing a live indirect-only video stream for any scene, regardless of geometric or photometric complexity; (2) capturing images that make existing structured-light shape recovery algorithms robust to indirect transport; and (3) turning them into one-shot methods for dynamic 3D shape capture. PMID:27295455

  9. Automated robust generation of compact 3D statistical shape models

    NASA Astrophysics Data System (ADS)

    Vrtovec, Tomaz; Likar, Bostjan; Tomazevic, Dejan; Pernus, Franjo

    2004-05-01

    Ascertaining the detailed shape and spatial arrangement of anatomical structures is important not only within diagnostic settings but also in the areas of planning, simulation, intraoperative navigation, and tracking of pathology. Robust, accurate and efficient automated segmentation of anatomical structures is difficult because of their complexity and inter-patient variability. Furthermore, the position of the patient during image acquisition, the imaging device and protocol, image resolution, and other factors induce additional variations in shape and appearance. Statistical shape models (SSMs) have proven quite successful in capturing structural variability. A possible approach to obtain a 3D SSM is to extract reference voxels by precisely segmenting the structure in one, reference image. The corresponding voxels in other images are determined by registering the reference image to each other image. The SSM obtained in this way describes statistically plausible shape variations over the given population as well as variations due to imperfect registration. In this paper, we present a completely automated method that significantly reduces shape variations induced by imperfect registration, thus allowing a more accurate description of variations. At each iteration, the derived SSM is used for coarse registration, which is further improved by describing finer variations of the structure. The method was tested on 64 lumbar spinal column CT scans, from which 23, 38, 45, 46 and 42 volumes of interest containing vertebra L1, L2, L3, L4 and L5, respectively, were extracted. Separate SSMs were generated for each vertebra. The results show that the method is capable of reducing the variations induced by registration errors.

  10. Saddle-Shaped Cyclic Indole Tetramers: 3D Electroactive Molecules.

    PubMed

    Ruiz, Constanza; Monge, Ángeles; Gutiérrez-Puebla, Enrique; Alkorta, Ibon; Elguero, José; Navarrete, Juan T López; Ruiz Delgado, M Carmen; Gómez-Lor, Berta

    2016-07-18

    We present a joint theoretical and experimental study of a series of cyclic indole tetramers aimed at understanding the fundamental electronic properties of this 3D platform and evaluating its potential in the construction of new semiconductors. To this end, we combined absorption and Raman spectroscopy, cyclic voltammetry, and spectroelectrochemistry with DFT calculations. Our results suggest that this platform can be easily and reversibly oxidized. Additionally, it has a HOMO that matches very well with the workfunction of gold, therefore charge injection from a gold electrode is expected to occur without significant barriers. Interestingly, the cyclic tetraindoles allow for good electron delocalization in spite of their saddle-shaped structures. The steric constraints introduced by N-substitution significantly inhibits ring inversion of the central cyclooctatetraene unit, whereas it only barely affects the optical and electrochemical properties (a slightly higher oxidation potential and a blueshifted absorption upon alkylation are observed). PMID:27320301

  11. The sinogram polygonizer for reconstructing 3D shapes.

    PubMed

    Yamanaka, Daiki; Ohtake, Yutaka; Suzuki, Hiromasa

    2013-11-01

    This paper proposes a novel approach, the sinogram polygonizer, for directly reconstructing 3D shapes from sinograms (i.e., the primary output from X-ray computed tomography (CT) scanners consisting of projection image sequences of an object shown from different viewing angles). To obtain a polygon mesh approximating the surface of a scanned object, a grid-based isosurface polygonizer, such as Marching Cubes, has been conventionally applied to the CT volume reconstructed from a sinogram. In contrast, the proposed method treats CT values as a continuous function and directly extracts a triangle mesh based on tetrahedral mesh deformation. This deformation involves quadratic error metric minimization and optimal Delaunay triangulation for the generation of accurate, high-quality meshes. Thanks to the analytical gradient estimation of CT values, sharp features are well approximated, even though the generated mesh is very coarse. Moreover, this approach eliminates aliasing artifacts on triangle meshes. PMID:24029910

  12. The Sinogram Polygonizer for Reconstructing 3D Shapes.

    PubMed

    Yamanaka, Daiki; Ohtake, Yutaka; Suzuki, Hiromasa

    2013-05-24

    This paper proposes a novel approach, the sinogram polygonizer, for directly reconstructing 3D shapes from sinograms (i.e., the primary output from X-ray computed tomography (CT) scanners consisting of projection image sequences of an object shown from different viewing angles). To obtain a polygon mesh approximating the surface of a scanned object, a grid-based isosurface polygonizer, such as Marching Cubes, has been conventionally applied to the CT volume reconstructed from a sinogram. In contrast, the proposed method treats CT values as a continuous function and directly extracts a triangle mesh based on tetrahedral mesh deformation. This deformation involves quadratic error metric minimization and optimal Delaunay triangulation for the generation of accurate, high-quality meshes. Thanks to the analytical gradient estimation of CT values, sharp features are well approximated, even though the generated mesh is very coarse. Moreover, this approach eliminates aliasing artifacts on triangle meshes. PMID:23712999

  13. 3D shape shearography with integrated structured light projection for strain inspection of curved objects

    NASA Astrophysics Data System (ADS)

    Anisimov, Andrei G.; Groves, Roger M.

    2015-05-01

    Shearography (speckle pattern shearing interferometry) is a non-destructive testing technique that provides full-field surface strain characterization. Although real-life objects especially in aerospace, transport or cultural heritage are not flat (e.g. aircraft leading edges or sculptures), their inspection with shearography is of interest for both hidden defect detection and material characterization. Accurate strain measuring of a highly curved or free form surface needs to be performed by combining inline object shape measuring and processing of shearography data in 3D. Previous research has not provided a general solution. This research is devoted to the practical questions of 3D shape shearography system development for surface strain characterization of curved objects. The complete procedure of calibration and data processing of a 3D shape shearography system with integrated structured light projector is presented. This includes an estimation of the actual shear distance and a sensitivity matrix correction within the system field of view. For the experimental part a 3D shape shearography system prototype was developed. It employs three spatially-distributed shearing cameras, with Michelson interferometers acting as the shearing devices, one illumination laser source and a structured light projector. The developed system performance was evaluated with a previously reported cylinder specimen (length 400 mm, external diameter 190 mmm) loaded by internal pressure. Further steps for the 3D shape shearography prototype and the technique development are also proposed.

  14. Full-hemisphere automatic optical 3D measurement system

    NASA Astrophysics Data System (ADS)

    Kuehmstedt, Peter; Notni, Gunther; Schreiber, Wolfgang; Gerber, Joerg

    1997-09-01

    The measurement of 3D object shapes for the purpose of digitization of CAD-models and for the complete manufacturing control of components are important tasks of modern industrial inspection. The proposed 3D measurement system using structured-light illumination has the ability to avoid illumination-caused difficulties, like shadowing and excessive light intensities by light reflection and diffraction at the surface of the object, while measuring technical surfaces. For this purpose, the object under test is successively illuminated with a periodic grating structure from at least three different directions, using a telecentric projection system. At least three linearly independent phase-measurement values are measured by gray- code techniques to calculate the 3D coordinates of the object points. The experimental setup allows the determination of phase-measurement values with illuminations from up to 16 different directions. This is connected with a simultaneous variation of the intensity of the projected grating structures. Thus, areas of shadows are `shifted' across the object surface to spots where they have no influence on the result of the measurement, and also specular effects can be suppressed. Furthermore, in order to obtain the entire surface, the object to be digitized must be covered by many overlapping views taken from different directions. To view the entire surface, the object is moved into various measuring positions, using a second rotation axis. These views are merged within an object-centered coordinate system and are automatically rearranged into a uniform grid. For this purpose, a calibration procedure has been developed to measure absolute coordinates within a defined object coordinate system, so that the combination of the particular images is simple, because all measurements are performed within the same system of object coordinates. The power of this concept has been experimentally demonstrated, for example, by measuring the complete 3D shape

  15. Measurement system for 3-D foot coordinates and parameters

    NASA Astrophysics Data System (ADS)

    Liu, Guozhong; Li, Yunhui; Wang, Boxiong; Shi, Hui; Luo, Xiuzhi

    2008-12-01

    The 3-D foot-shape measurement system based on laser-line-scanning principle and the model of the measurement system were presented. Errors caused by nonlinearity of CCD cameras and caused by installation can be eliminated by using the global calibration method for CCD cameras, which based on nonlinear coordinate mapping function and the optimized method. A local foot coordinate system is defined with the Pternion and the Acropodion extracted from the boundaries of foot projections. The characteristic points can thus be located and foot parameters be extracted automatically by the local foot coordinate system and the related sections. Foot measurements for about 200 participants were conducted and the measurement results for male and female participants were presented. 3-D foot coordinates and parameters measurement makes it possible to realize custom-made shoe-making and shows great prosperity in shoe design, foot orthopaedic treatment, shoe size standardization, and establishment of a feet database for consumers.

  16. Polygonal Shapes Detection in 3d Models of Complex Architectures

    NASA Astrophysics Data System (ADS)

    Benciolini, G. B.; Vitti, A.

    2015-02-01

    A sequential application of two global models defined on a variational framework is proposed for the detection of polygonal shapes in 3D models of complex architectures. As a first step, the procedure involves the use of the Mumford and Shah (1989) 1st-order variational model in dimension two (gridded height data are processed). In the Mumford-Shah model an auxiliary function detects the sharp changes, i.e., the discontinuities, of a piecewise smooth approximation of the data. The Mumford-Shah model requires the global minimization of a specific functional to simultaneously produce both the smooth approximation and its discontinuities. In the proposed procedure, the edges of the smooth approximation derived by a specific processing of the auxiliary function are then processed using the Blake and Zisserman (1987) 2nd-order variational model in dimension one (edges are processed in the plane). This second step permits to describe the edges of an object by means of piecewise almost-linear approximation of the input edges themselves and to detects sharp changes of the first-derivative of the edges so to detect corners. The Mumford-Shah variational model is used in two dimensions accepting the original data as primary input. The Blake-Zisserman variational model is used in one dimension for the refinement of the description of the edges. The selection among all the boundaries detected by the Mumford-Shah model of those that present a shape close to a polygon is performed by considering only those boundaries for which the Blake-Zisserman model identified discontinuities in their first derivative. The output of the procedure are hence shapes, coming from 3D geometric data, that can be considered as polygons. The application of the procedure is suitable for, but not limited to, the detection of objects such as foot-print of polygonal buildings, building facade boundaries or windows contours. v The procedure is applied to a height model of the building of the Engineering

  17. Key techniques for vision measurement of 3D object surface

    NASA Astrophysics Data System (ADS)

    Yang, Huachao; Zhang, Shubi; Guo, Guangli; Liu, Chao; Yu, Ruipeng

    2006-11-01

    Digital close-range photogrammetry system and machine vision are widely used in production control, quality inspection. The main aim is to provide accurate 3D objects or reconstruction of an object surface and give an expression to an object shape. First, the key techniques of camera calibration and target image positioning for 3D object surface vision measurement were briefly reviewed and analyzed in this paper. Then, an innovative and effect method for precise space coordinates measurements was proposed. Test research proved that the thought and methods we proposed about image segmentation, detection and positioning of circular marks were effective and valid. A propriety weight value for adding parameters, control points and orientation elements in bundle adjustment with self-calibration are advantageous to gaining high accuracy of space coordinates. The RMS error of check points is less than +/-1 mm, which can meet the requirement in industrial measurement with high accuracy.

  18. Automatic segmentation of the fetal cerebellum on ultrasound volumes, using a 3D statistical shape model.

    PubMed

    Gutiérrez-Becker, Benjamín; Arámbula Cosío, Fernando; Guzmán Huerta, Mario E; Benavides-Serralde, Jesús Andrés; Camargo-Marín, Lisbeth; Medina Bañuelos, Verónica

    2013-09-01

    Previous work has shown that the segmentation of anatomical structures on 3D ultrasound data sets provides an important tool for the assessment of the fetal health. In this work, we present an algorithm based on a 3D statistical shape model to segment the fetal cerebellum on 3D ultrasound volumes. This model is adjusted using an ad hoc objective function which is in turn optimized using the Nelder-Mead simplex algorithm. Our algorithm was tested on ultrasound volumes of the fetal brain taken from 20 pregnant women, between 18 and 24 gestational weeks. An intraclass correlation coefficient of 0.8528 and a mean Dice coefficient of 0.8 between cerebellar volumes measured using manual techniques and the volumes calculated using our algorithm were obtained. As far as we know, this is the first effort to automatically segment fetal intracranial structures on 3D ultrasound data. PMID:23686392

  19. Analysis of method of 3D shape reconstruction using scanning deflectometry

    NASA Astrophysics Data System (ADS)

    Novák, Jiří; Novák, Pavel; Mikš, Antonín.

    2013-04-01

    This work presents a scanning deflectometric approach to solving a 3D surface reconstruction problem, which is based on measurements of a surface gradient of optically smooth surfaces. It is shown that a description of this problem leads to a nonlinear partial differential equation (PDE) of the first order, from which the surface shape can be reconstructed numerically. The method for effective finding of the solution of this differential equation is proposed, which is based on the transform of the problem of PDE solving to the optimization problem. We describe different types of surface description for the shape reconstruction and a numerical simulation of the presented method is performed. The reconstruction process is analyzed by computer simulations and presented on examples. The performed analysis confirms a robustness of the reconstruction method and a good possibility for measurements and reconstruction of the 3D shape of specular surfaces.

  20. Faceless identification: a model for person identification using the 3D shape and 3D motion as cues

    NASA Astrophysics Data System (ADS)

    Klasen, Lena M.; Li, Haibo

    1999-02-01

    Person identification by using biometric methods based on image sequences, or still images, often requires a controllable and cooperative environment during the image capturing stage. In the forensic case the situation is more likely to be the opposite. In this work we propose a method that makes use of the anthropometry of the human body and human actions as cues for identification. Image sequences from surveillance systems are used, which can be seen as monocular image sequences. A 3D deformable wireframe body model is used as a platform to handle the non-rigid information of the 3D shape and 3D motion of the human body from the image sequence. A recursive method for estimating global motion and local shape variations is presented, using two recursive feedback systems.

  1. Measurements of Polarization Transfers in Real Compton Scattering by a proton target at JLAB. A new source of information on the 3D shape of the nucleon

    SciTech Connect

    Fanelli, Cristiano V.

    2015-03-01

    In this thesis work, results of the analysis of the polarization transfers measured in real Compton scattering (RCS) by the Collaboration E07-002 at the Je fferson Lab Hall-C are presented. The data were collected at large scattering angle (theta_cm = 70deg) and with a polarized incident photon beam at an average energy of 3.8 GeV. Such a kind of experiments allows one to understand more deeply the reaction mechanism, that involves a real photon, by extracting both Compton form factors and Generalized Parton Distributions (GPDs) (also relevant for possibly shedding light on the total angular momentum of the nucleon). The obtained results for the longitudinal and transverse polarization transfers K_LL and K_LT, are of crucial importance, since they confirm unambiguously the disagreement between experimental data and pQCD prediction, as it was found in E99-114 experiment, and favor the Handbag mechanism. The E99-114 and E07-002 results can contribute to attract new interest on the great yield of the Compton scattering by a nucleon target, as demonstrated by the recent approval of an experimental proposal submitted to the Jefferson Lab PAC 42 for a Wide-angle Compton Scattering experiment, at 8 and 10 GeV Photon Energies. The new experiments approved to run with the updated 12 GeV electron beam at JLab, are characterized by much higher luminosities, and a new GEM tracker is under development to tackle the challenging backgrounds. Within this context, we present a new multistep tracking algorithm, based on (i) a Neural Network (NN) designed for a fast and efficient association of the hits measured by the GEM detector which allows the track identification, and (ii) the application of both a Kalman filter and Rauch-Tung-Striebel smoother to further improve the track reconstruction. The full procedure, i.e. NN and filtering, appears very promising, with high performances in terms of both association effciency and reconstruction accuracy, and these preliminary results will

  2. Measuring Actin Flow in 3D Cell Protrusions

    PubMed Central

    Chiu, Chi-Li; Digman, Michelle A.; Gratton, Enrico

    2013-01-01

    Actin dynamics is important in determining cell shape, tension, and migration. Methods such as fluorescent speckle microscopy and spatial temporal image correlation spectroscopy have been used to capture high-resolution actin turnover dynamics within cells in two dimensions. However, these methods are not directly applicable in 3D due to lower resolution and poor contrast. Here, we propose to capture actin flow in 3D with high spatial-temporal resolution by combining nanoscale precise imaging by rapid beam oscillation and fluctuation spectroscopy techniques. To measure the actin flow along cell protrusions in cell expressing actin-eGFP cultured in a type I collagen matrix, the laser was orbited around the protrusion and its trajectory was modulated in a clover-shaped pattern perpendicularly to the protrusion. Orbits were also alternated at two positions closely spaced along the protrusion axis. The pair cross-correlation function was applied to the fluorescence fluctuation from these two positions to capture the flow of actin. Measurements done on nonmoving cellular protrusion tips showed no pair-correlation at two orbital positions indicating a lack of flow of F-actin bundles. However, in some protrusions, the pair-correlation approach revealed directional flow of F-actin bundles near the protrusion surface with flow rates in the range of ∼1 μm/min, comparable to results in two dimensions using fluorescent speckle microscopy. Furthermore, we found that the actin flow rate is related to the distance to the protrusion tip. We also observed collagen deformation by concomitantly detecting collagen fibers with reflectance detection during these actin motions. The implementation of the nanoscale precise imaging by rapid beam oscillation method with a cloverleaf-shaped trajectory in conjunction with the pair cross-correlation function method provides a quantitative way of capturing dynamic flows and organization of proteins during cell migration in 3D in conditions of

  3. Multi-shape active composites by 3D printing of digital shape memory polymers

    NASA Astrophysics Data System (ADS)

    Wu, Jiangtao; Yuan, Chao; Ding, Zhen; Isakov, Michael; Mao, Yiqi; Wang, Tiejun; Dunn, Martin L.; Qi, H. Jerry

    2016-04-01

    Recent research using 3D printing to create active structures has added an exciting new dimension to 3D printing technology. After being printed, these active, often composite, materials can change their shape over time; this has been termed as 4D printing. In this paper, we demonstrate the design and manufacture of active composites that can take multiple shapes, depending on the environmental temperature. This is achieved by 3D printing layered composite structures with multiple families of shape memory polymer (SMP) fibers – digital SMPs - with different glass transition temperatures (Tg) to control the transformation of the structure. After a simple single-step thermomechanical programming process, the fiber families can be sequentially activated to bend when the temperature is increased. By tuning the volume fraction of the fibers, bending deformation can be controlled. We develop a theoretical model to predict the deformation behavior for better understanding the phenomena and aiding the design. We also design and print several flat 2D structures that can be programmed to fold and open themselves when subjected to heat. With the advantages of an easy fabrication process and the controllable multi-shape memory effect, the printed SMP composites have a great potential in 4D printing applications.

  4. Multi-shape active composites by 3D printing of digital shape memory polymers.

    PubMed

    Wu, Jiangtao; Yuan, Chao; Ding, Zhen; Isakov, Michael; Mao, Yiqi; Wang, Tiejun; Dunn, Martin L; Qi, H Jerry

    2016-01-01

    Recent research using 3D printing to create active structures has added an exciting new dimension to 3D printing technology. After being printed, these active, often composite, materials can change their shape over time; this has been termed as 4D printing. In this paper, we demonstrate the design and manufacture of active composites that can take multiple shapes, depending on the environmental temperature. This is achieved by 3D printing layered composite structures with multiple families of shape memory polymer (SMP) fibers - digital SMPs - with different glass transition temperatures (Tg) to control the transformation of the structure. After a simple single-step thermomechanical programming process, the fiber families can be sequentially activated to bend when the temperature is increased. By tuning the volume fraction of the fibers, bending deformation can be controlled. We develop a theoretical model to predict the deformation behavior for better understanding the phenomena and aiding the design. We also design and print several flat 2D structures that can be programmed to fold and open themselves when subjected to heat. With the advantages of an easy fabrication process and the controllable multi-shape memory effect, the printed SMP composites have a great potential in 4D printing applications. PMID:27071543

  5. Multi-shape active composites by 3D printing of digital shape memory polymers

    PubMed Central

    Wu, Jiangtao; Yuan, Chao; Ding, Zhen; Isakov, Michael; Mao, Yiqi; Wang, Tiejun; Dunn, Martin L.; Qi, H. Jerry

    2016-01-01

    Recent research using 3D printing to create active structures has added an exciting new dimension to 3D printing technology. After being printed, these active, often composite, materials can change their shape over time; this has been termed as 4D printing. In this paper, we demonstrate the design and manufacture of active composites that can take multiple shapes, depending on the environmental temperature. This is achieved by 3D printing layered composite structures with multiple families of shape memory polymer (SMP) fibers – digital SMPs - with different glass transition temperatures (Tg) to control the transformation of the structure. After a simple single-step thermomechanical programming process, the fiber families can be sequentially activated to bend when the temperature is increased. By tuning the volume fraction of the fibers, bending deformation can be controlled. We develop a theoretical model to predict the deformation behavior for better understanding the phenomena and aiding the design. We also design and print several flat 2D structures that can be programmed to fold and open themselves when subjected to heat. With the advantages of an easy fabrication process and the controllable multi-shape memory effect, the printed SMP composites have a great potential in 4D printing applications. PMID:27071543

  6. Amygdala–hippocampal shape differences in schizophrenia: the application of 3D shape models to volumetric MR data

    PubMed Central

    Shenton, Martha E.; Gerig, Guido; McCarley, Robert W.; Székely, Gábor; Kikinis, Ron

    2010-01-01

    Evidence suggests that some structural brain abnormalities in schizophrenia are neurodevelopmental in origin. There is also growing evidence to suggest that shape deformations in brain structure may reflect abnormalities in neurodevelopment. While many magnetic resonance (MR) imaging studies have investigated brain area and volume measures in schizophrenia, fewer have focused on shape deformations. In this MR study we used a 3D shape representation technique, based on spherical harmonic functions, to analyze left and right amygdala-hippocampus shapes in each of 15 patients with schizophrenia and 15 healthy controls matched for age, gender, handedness and parental socioeconomic status. Left/right asymmetry was also measured for both shape and volume differences. Additionally, shape and volume measurements were combined in a composite analysis. There were no differences between groups in overall volume or shape. Left/right amygdala–hippocampal asymmetry, however, was significantly larger in patients than controls for both relative volume and shape. The local brain regions responsible for the left/right asymmetry differences in patients with schizophrenia were in the tail of the hippocampus (including both the inferior aspect adjacent to parahippocampal gyrus and the superior aspect adjacent to the lateral geniculate nucleus and more anteriorly to the cerebral peduncles) and in portions of the amygdala body (including the anterior–superior aspect adjacent to the basal nucleus). Also, in patients, increased volumetric asymmetry tended to be correlated with increased left/right shape asymmetry. Furthermore, a combined analysis of volume and shape asymmetry resulted in improved differentiation between groups. Classification function analyses correctly classified 70% of cases using volume, 73.3% using shape, and 87% using combined volume and shape measures. These findings suggest that shape provides important new information toward characterizing the pathophysiology

  7. 3D statistical shape models incorporating 3D random forest regression voting for robust CT liver segmentation

    NASA Astrophysics Data System (ADS)

    Norajitra, Tobias; Meinzer, Hans-Peter; Maier-Hein, Klaus H.

    2015-03-01

    During image segmentation, 3D Statistical Shape Models (SSM) usually conduct a limited search for target landmarks within one-dimensional search profiles perpendicular to the model surface. In addition, landmark appearance is modeled only locally based on linear profiles and weak learners, altogether leading to segmentation errors from landmark ambiguities and limited search coverage. We present a new method for 3D SSM segmentation based on 3D Random Forest Regression Voting. For each surface landmark, a Random Regression Forest is trained that learns a 3D spatial displacement function between the according reference landmark and a set of surrounding sample points, based on an infinite set of non-local randomized 3D Haar-like features. Landmark search is then conducted omni-directionally within 3D search spaces, where voxelwise forest predictions on landmark position contribute to a common voting map which reflects the overall position estimate. Segmentation experiments were conducted on a set of 45 CT volumes of the human liver, of which 40 images were randomly chosen for training and 5 for testing. Without parameter optimization, using a simple candidate selection and a single resolution approach, excellent results were achieved, while faster convergence and better concavity segmentation were observed, altogether underlining the potential of our approach in terms of increased robustness from distinct landmark detection and from better search coverage.

  8. 3D Printing: 3D Printing of Shape Memory Polymers for Flexible Electronic Devices (Adv. Mater. 22/2016).

    PubMed

    Zarek, Matt; Layani, Michael; Cooperstein, Ido; Sachyani, Ela; Cohn, Daniel; Magdassi, Shlomo

    2016-06-01

    On page 4449, D. Cohn, S. Magdassi, and co-workers describe a general and facile method based on 3D printing of methacrylated macromonomers to fabricate shape-memory objects that can be used in flexible and responsive electrical circuits. Such responsive objects can be used in the fabrication of soft robotics, minimal invasive medical devices, sensors, and wearable electronics. The use of 3D printing overcomes the poor processing characteristics of thermosets and enables complex geometries that are not easily accessible by other techniques. PMID:27273436

  9. 3D measurement of human face by stereophotogrammetry

    NASA Astrophysics Data System (ADS)

    Wagner, Holger; Wiegmann, Axel; Kowarschik, Richard; Zöllner, Friedrich

    2006-01-01

    The following article describes a stereophotogrammetry based technique for 3D measurement of human faces. The method was developed for function orientated diagnostics and therapy in dentistry to provide prognoses for jaw-growth or surgical procedures. The main aim of our activities was to realize both -- a rapid measurement and a dense point cloud. The setup consists of two digital cameras in a convergent arrangement and a digital projector. During the measurement a rapid sequence of about 20 statistical generated patterns were projected onto the face and synchronously captured by the two cameras. Therefore, every single pixel of the two cameras is encoded by a characteristically stack of intensity values. To find corresponding points into the image sequences a correlation technique is used. At least, the 3D reconstruction is done by triangulation. The advantages of the shown method are the possible short measurement time (< 1 second) and - in comparison to gray code and phase shift techniques - the low quality requirements of the projection unit. At present the reached accuracy is +/- 0.1mm (rms), which is sufficient for medical applications. But the demonstrated method is not restricted to evaluate the shape of human faces. Also technical objects could be measured.

  10. 3D shape modeling by integration visual and tactile cues

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming

    2015-10-01

    With the progress in CAD (Computer Aided Design) systems, many mechanical components can be designed efficiently with high precision. But, such a system is unfit for some organic shapes, for example, a toy. In this paper, an easy way to dealing with such shapes is presented, combing visual perception with tangible interaction. The method is divided into three phases: two tangible interaction phases and one visual reconstruction. In the first tangible phase, a clay model is used to represent the raw shape, and the designer can change the shape intuitively with his hands. Then the raw shape is scanned into a digital volume model through a low cost vision system. In the last tangible phase, a desktop haptic device from SensAble is used to refine the scanned volume model and convert it into a surface model. A physical clay model and a virtual clay mode are all used in this method to deal with the main shape and the details respectively, and the vision system is used to bridge the two tangible phases. The vision reconstruction system is only made of a camera to acquire raw shape through shape from silhouettes method. All of the systems are installed on a single desktop, make it convenient for designers. The vision system details and a design example are presented in the papers.

  11. Cladding waveguide gratings in standard single-mode fiber for 3D shape sensing.

    PubMed

    Waltermann, Christian; Doering, Alexander; Köhring, Michael; Angelmahr, Martin; Schade, Wolfgang

    2015-07-01

    Femtosecond laser pulses were used for the direct point-by-point inscription of waveguides into the cladding of standard single-mode fibers. Homogeneous S-shaped waveguides have been processed as a bundle of overlapping lines without damaging the surrounding material. Within these structures, FBGs have been successfully inscribed and characterized. A sensor device to measure the bending direction of a fiber was created by two perpendicular inscribed cladding waveguides with FBG. Finally, a complete 3D shape sensor consisting of several bending sensor planes, capable of detecting bending radii even below 2.5 cm is demonstrated. PMID:26125379

  12. Identifying Virtual 3D Geometric Shapes with a Vibrotactile Glove.

    PubMed

    Martínez, Jonatan; García, Arturo; Oliver, Miguel; Molina, José Pascual; González, Pascual

    2016-01-01

    The emergence of off-screen interaction devices is bringing the field of virtual reality to a broad range of applications where virtual objects can be manipulated without the use of traditional peripherals. However, to facilitate object interaction, other stimuli such as haptic feedback are necessary to improve the user experience. To enable the identification of virtual 3D objects without visual feedback, a haptic display based on a vibrotactile glove and multiple points of contact gives users an enhanced sensation of touching a virtual object with their hands. Experimental results demonstrate the capacity of this technology in practical applications. PMID:25137722

  13. 3D shape reconstruction of medical images using a perspective shape-from-shading method

    NASA Astrophysics Data System (ADS)

    Yang, Lei; Han, Jiu-qiang

    2008-06-01

    A 3D shape reconstruction approach for medical images using a shape-from-shading (SFS) method was proposed in this paper. A new reflectance map equation of medical images was analyzed with the assumption that the Lambertian reflectance surface was irradiated by a point light source located at the light center and the image was formed under perspective projection. The corresponding static Hamilton-Jacobi (H-J) equation of the reflectance map equation was established. So the shape-from-shading problem turned into solving the viscosity solution of the static H-J equation. Then with the conception of a viscosity vanishing approximation, the Lax-Friedrichs fast sweeping numerical method was used to compute the viscosity solution of the H-J equation and a new iterative SFS algorithm was gained. Finally, experiments on both synthetic images and real medical images were performed to illustrate the efficiency of the proposed SFS method.

  14. Shape 4.0: 3D Shape Modeling and Processing Using Semantics.

    PubMed

    Spagnuolo, Michela

    2016-01-01

    In the last decade, sensor, communication, and computing technologies have advanced rapidly, producing dramatic changes in our daily lives and in a variety of application domains. Emerging technologies are leading us to a gradual, but inescapable integration of our material and digital realities and the advent of cyber-physical worlds. Although attaining visual realism is within the grasp of current 3D modeling approaches, it is less clear whether current modeling techniques will accommodate the needs of human communication and of the applications that we can already envisage in those futuristic worlds. Inspired by the evolution trends of the Web, this article describes the evolution of shape modeling from the Shape 1.0 geometry-only, mesh-based stage to the forthcoming semantics-driven Shape 4.0 era. PMID:26780764

  15. Optical characterization and measurements of autostereoscopic 3D displays

    NASA Astrophysics Data System (ADS)

    Salmimaa, Marja; Järvenpää, Toni

    2008-04-01

    3D or autostereoscopic display technologies offer attractive solutions for enriching the multimedia experience. However, both characterization and comparison of 3D displays have been challenging when the definitions for the consistent measurement methods have been lacking and displays with similar specifications may appear quite different. Earlier we have investigated how the optical properties of autostereoscopic (3D) displays can be objectively measured and what are the main characteristics defining the perceived image quality. In this paper the discussion is extended to cover the viewing freedom (VF) and the definition for the optimum viewing distance (OVD) is elaborated. VF is the volume inside which the eyes have to be to see an acceptable 3D image. Characteristics limiting the VF space are proposed to be 3D crosstalk, luminance difference and color difference. Since the 3D crosstalk can be presumed to be dominating the quality of the end user experience and in our approach is forming the basis for the calculations of the other optical parameters, the reliability of the 3D crosstalk measurements is investigated. Furthermore the effect on the derived VF definition is evaluated. We have performed comparison 3D crosstalk measurements with different measurement device apertures and the effect of different measurement geometry on the results on actual 3D displays is reported.

  16. 3D Printing of Shape Memory Polymers for Flexible Electronic Devices.

    PubMed

    Zarek, Matt; Layani, Michael; Cooperstein, Ido; Sachyani, Ela; Cohn, Daniel; Magdassi, Shlomo

    2016-06-01

    The formation of 3D objects composed of shape memory polymers for flexible electronics is described. Layer-by-layer photopolymerization of methacrylated semicrystalline molten macromonomers by a 3D digital light processing printer enables rapid fabrication of complex objects and imparts shape memory functionality for electrical circuits. PMID:26402320

  17. Conformal geometry and its applications on 3D shape matching, recognition, and stitching.

    PubMed

    Wang, Sen; Wang, Yang; Jin, Miao; Gu, Xianfeng David; Samaras, Dimitris

    2007-07-01

    Three-dimensional shape matching is a fundamental issue in computer vision with many applications such as shape registration, 3D object recognition, and classification. However, shape matching with noise, occlusion, and clutter is a challenging problem. In this paper, we analyze a family of quasi-conformal maps including harmonic maps, conformal maps, and least-squares conformal maps with regards to 3D shape matching. As a result, we propose a novel and computationally efficient shape matching framework by using least-squares conformal maps. According to conformal geometry theory, each 3D surface with disk topology can be mapped to a 2D domain through a global optimization and the resulting map is a diffeomorphism, i.e., one-to-one and onto. This allows us to simplify the 3D shape-matching problem to a 2D image-matching problem, by comparing the resulting 2D parametric maps, which are stable, insensitive to resolution changes and robust to occlusion, and noise. Therefore, highly accurate and efficient 3D shape matching algorithms can be achieved by using the above three parametric maps. Finally, the robustness of least-squares conformal maps is evaluated and analyzed comprehensively in 3D shape matching with occlusion, noise, and resolution variation. In order to further demonstrate the performance of our proposed method, we also conduct a series of experiments on two computer vision applications, i.e., 3D face recognition and 3D nonrigid surface alignment and stitching. PMID:17496378

  18. 3D Shape Perception in Posterior Cortical Atrophy: A Visual Neuroscience Perspective

    PubMed Central

    Gillebert, Céline R.; Schaeverbeke, Jolien; Bastin, Christine; Neyens, Veerle; Bruffaerts, Rose; De Weer, An-Sofie; Seghers, Alexandra; Sunaert, Stefan; Van Laere, Koen; Versijpt, Jan; Vandenbulcke, Mathieu; Salmon, Eric; Todd, James T.; Orban, Guy A.

    2015-01-01

    Posterior cortical atrophy (PCA) is a rare focal neurodegenerative syndrome characterized by progressive visuoperceptual and visuospatial deficits, most often due to atypical Alzheimer's disease (AD). We applied insights from basic visual neuroscience to analyze 3D shape perception in humans affected by PCA. Thirteen PCA patients and 30 matched healthy controls participated, together with two patient control groups with diffuse Lewy body dementia (DLBD) and an amnestic-dominant phenotype of AD, respectively. The hierarchical study design consisted of 3D shape processing for 4 cues (shading, motion, texture, and binocular disparity) with corresponding 2D and elementary feature extraction control conditions. PCA and DLBD exhibited severe 3D shape-processing deficits and AD to a lesser degree. In PCA, deficient 3D shape-from-shading was associated with volume loss in the right posterior inferior temporal cortex. This region coincided with a region of functional activation during 3D shape-from-shading in healthy controls. In PCA patients who performed the same fMRI paradigm, response amplitude during 3D shape-from-shading was reduced in this region. Gray matter volume in this region also correlated with 3D shape-from-shading in AD. 3D shape-from-disparity in PCA was associated with volume loss slightly more anteriorly in posterior inferior temporal cortex as well as in ventral premotor cortex. The findings in right posterior inferior temporal cortex and right premotor cortex are consistent with neurophysiologically based models of the functional anatomy of 3D shape processing. However, in DLBD, 3D shape deficits rely on mechanisms distinct from inferior temporal structural integrity. SIGNIFICANCE STATEMENT Posterior cortical atrophy (PCA) is a neurodegenerative syndrome characterized by progressive visuoperceptual dysfunction and most often an atypical presentation of Alzheimer's disease (AD) affecting the ventral and dorsal visual streams rather than the medial

  19. 3D Image Acquisition System Based on Shape from Focus Technique

    PubMed Central

    Billiot, Bastien; Cointault, Frédéric; Journaux, Ludovic; Simon, Jean-Claude; Gouton, Pierre

    2013-01-01

    This paper describes the design of a 3D image acquisition system dedicated to natural complex scenes composed of randomly distributed objects with spatial discontinuities. In agronomic sciences, the 3D acquisition of natural scene is difficult due to the complex nature of the scenes. Our system is based on the Shape from Focus technique initially used in the microscopic domain. We propose to adapt this technique to the macroscopic domain and we detail the system as well as the image processing used to perform such technique. The Shape from Focus technique is a monocular and passive 3D acquisition method that resolves the occlusion problem affecting the multi-cameras systems. Indeed, this problem occurs frequently in natural complex scenes like agronomic scenes. The depth information is obtained by acting on optical parameters and mainly the depth of field. A focus measure is applied on a 2D image stack previously acquired by the system. When this focus measure is performed, we can create the depth map of the scene. PMID:23591964

  20. a Fast Method for Measuring the Similarity Between 3d Model and 3d Point Cloud

    NASA Astrophysics Data System (ADS)

    Zhang, Zongliang; Li, Jonathan; Li, Xin; Lin, Yangbin; Zhang, Shanxin; Wang, Cheng

    2016-06-01

    This paper proposes a fast method for measuring the partial Similarity between 3D Model and 3D point Cloud (SimMC). It is crucial to measure SimMC for many point cloud-related applications such as 3D object retrieval and inverse procedural modelling. In our proposed method, the surface area of model and the Distance from Model to point Cloud (DistMC) are exploited as measurements to calculate SimMC. Here, DistMC is defined as the weighted distance of the distances between points sampled from model and point cloud. Similarly, Distance from point Cloud to Model (DistCM) is defined as the average distance of the distances between points in point cloud and model. In order to reduce huge computational burdens brought by calculation of DistCM in some traditional methods, we define SimMC as the ratio of weighted surface area of model to DistMC. Compared to those traditional SimMC measuring methods that are only able to measure global similarity, our method is capable of measuring partial similarity by employing distance-weighted strategy. Moreover, our method is able to be faster than other partial similarity assessment methods. We demonstrate the superiority of our method both on synthetic data and laser scanning data.

  1. Sequential Self-Folding Structures by 3D Printed Digital Shape Memory Polymers.

    PubMed

    Mao, Yiqi; Yu, Kai; Isakov, Michael S; Wu, Jiangtao; Dunn, Martin L; Jerry Qi, H

    2015-01-01

    Folding is ubiquitous in nature with examples ranging from the formation of cellular components to winged insects. It finds technological applications including packaging of solar cells and space structures, deployable biomedical devices, and self-assembling robots and airbags. Here we demonstrate sequential self-folding structures realized by thermal activation of spatially-variable patterns that are 3D printed with digital shape memory polymers, which are digital materials with different shape memory behaviors. The time-dependent behavior of each polymer allows the temporal sequencing of activation when the structure is subjected to a uniform temperature. This is demonstrated via a series of 3D printed structures that respond rapidly to a thermal stimulus, and self-fold to specified shapes in controlled shape changing sequences. Measurements of the spatial and temporal nature of self-folding structures are in good agreement with the companion finite element simulations. A simplified reduced-order model is also developed to rapidly and accurately describe the self-folding physics. An important aspect of self-folding is the management of self-collisions, where different portions of the folding structure contact and then block further folding. A metric is developed to predict collisions and is used together with the reduced-order model to design self-folding structures that lock themselves into stable desired configurations. PMID:26346202

  2. Sequential Self-Folding Structures by 3D Printed Digital Shape Memory Polymers

    PubMed Central

    Mao, Yiqi; Yu, Kai; Isakov, Michael S.; Wu, Jiangtao; Dunn, Martin L.; Jerry Qi, H.

    2015-01-01

    Folding is ubiquitous in nature with examples ranging from the formation of cellular components to winged insects. It finds technological applications including packaging of solar cells and space structures, deployable biomedical devices, and self-assembling robots and airbags. Here we demonstrate sequential self-folding structures realized by thermal activation of spatially-variable patterns that are 3D printed with digital shape memory polymers, which are digital materials with different shape memory behaviors. The time-dependent behavior of each polymer allows the temporal sequencing of activation when the structure is subjected to a uniform temperature. This is demonstrated via a series of 3D printed structures that respond rapidly to a thermal stimulus, and self-fold to specified shapes in controlled shape changing sequences. Measurements of the spatial and temporal nature of self-folding structures are in good agreement with the companion finite element simulations. A simplified reduced-order model is also developed to rapidly and accurately describe the self-folding physics. An important aspect of self-folding is the management of self-collisions, where different portions of the folding structure contact and then block further folding. A metric is developed to predict collisions and is used together with the reduced-order model to design self-folding structures that lock themselves into stable desired configurations. PMID:26346202

  3. Sequential Self-Folding Structures by 3D Printed Digital Shape Memory Polymers

    NASA Astrophysics Data System (ADS)

    Mao, Yiqi; Yu, Kai; Isakov, Michael S.; Wu, Jiangtao; Dunn, Martin L.; Jerry Qi, H.

    2015-09-01

    Folding is ubiquitous in nature with examples ranging from the formation of cellular components to winged insects. It finds technological applications including packaging of solar cells and space structures, deployable biomedical devices, and self-assembling robots and airbags. Here we demonstrate sequential self-folding structures realized by thermal activation of spatially-variable patterns that are 3D printed with digital shape memory polymers, which are digital materials with different shape memory behaviors. The time-dependent behavior of each polymer allows the temporal sequencing of activation when the structure is subjected to a uniform temperature. This is demonstrated via a series of 3D printed structures that respond rapidly to a thermal stimulus, and self-fold to specified shapes in controlled shape changing sequences. Measurements of the spatial and temporal nature of self-folding structures are in good agreement with the companion finite element simulations. A simplified reduced-order model is also developed to rapidly and accurately describe the self-folding physics. An important aspect of self-folding is the management of self-collisions, where different portions of the folding structure contact and then block further folding. A metric is developed to predict collisions and is used together with the reduced-order model to design self-folding structures that lock themselves into stable desired configurations.

  4. Steering knuckle diameter measurement based on optical 3D scanning

    NASA Astrophysics Data System (ADS)

    Song, Li-mei; Li, Da-peng; Chang, Yu-lan; Xi, Jiang-tao; Guo, Qing-hua

    2014-11-01

    To achieve accurate measurements, the creating a fitting hole for internal diameter (CFHID) measurement method and the establishing multi-sectional curve for external diameter (EMCED) measurement method are proposed in this paper, which are based on computer vision principle and three-dimensional (3D) reconstruction. The methods are able to highlight the 3D characteristics of the scanned object and to achieve the accurate measurement of 3D data. It can create favorable conditions for realizing the reverse design and 3D reconstruction of scanned object. These methods can also be applied to dangerous work environment or the occasion that traditional contact measurement can not meet the demands, and they can improve the security in measurement.

  5. Experimental investigation on a novel 3D isolator made of shape memory alloy pseudo-rubber

    NASA Astrophysics Data System (ADS)

    Li, Su-chao; Guo, An-xin; Mao, Chen-xi; Li, Hui; Zhao, Yagebai

    2015-04-01

    Base isolation technology has been widely theoretically and experimentally investigated, and it has also been verified through many severe earthquakes. Three dimensional (3-D) isolation technology was proposed several years ago, and the 3-D isolation theory has well developed till now. However, the development of 3-D isolation technology was deeply affected by the 3-D isolator devices. Many presented 3-D isolators are generally made up of complicated components, such as rubber, springs, dampers or theirs combinations. These isolators have some problem in certain extent, such as difficult fabrication process or little energy dissipation ability along the vertical direction. This paper presents a novel 3- D isolator which is made up of martensitic shape memory alloy wires through weaving, rolling, and punching. Mechanical properties of 3-D shape memory alloy pseudo-rubber isolator (SMAPRI) are investigated including compression, shear, and compression-shear loading with different frequencies and amplitudes. The mechanical behavior of isolators with different parameters is also compared. Accordingly, the mechanism resulting in the above differences is also analyzed. Experimental results indicated that 3-D SMAPRI has good mechanical properties and energy dissipation ability along both of horizontal and vertical direction. The fabrication process of the proposed 3-D isolator is relatively easy and the mechanism of isolation is clearer than the traditional 3-D isolators. Therefore, this new kind of 3-D isolator has good potentiality in both of seismic isolation for civil infrastructures and industrial isolation for important or precision equipment.

  6. Shape design sensitivities using fully automatic 3-D mesh generation

    NASA Technical Reports Server (NTRS)

    Botkin, M. E.

    1990-01-01

    Previous work in three dimensional shape optimization involved specifying design variables by associating parameters directly with mesh points. More recent work has shown the use of fully-automatic mesh generation based upon a parameterized geometric representation. Design variables have been associated with a mathematical model of the part rather than the discretized representation. The mesh generation procedure uses a nonuniform grid intersection technique to place nodal points directly on the surface geometry. Although there exists an associativity between the mesh and the geometrical/topological entities, there is no mathematical functional relationship. This poses a problem during certain steps in the optimization process in which geometry modification is required. For the large geometrical changes which occur at the beginning of each optimization step, a completely new mesh is created. However, for gradient calculations many small changes must be made and it would be too costly to regenerate the mesh for each design variable perturbation. For that reason, a local remeshing procedure has been implemented which operates only on the specific edges and faces associated with the design variable being perturbed. Two realistic design problems are presented which show the efficiency of this process and test the accuracy of the gradient computations.

  7. Implementation and Validation of 3-D Ice Accretion Measurement Methodology

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Broeren, Andy P.; Kreeger, Richard E.; Potapczuk, Mark; Utt, Lloyd

    2014-01-01

    A research program has been implemented to develop and validate the use of a commercial 3-D laser scanning system to record ice accretion geometry in the NASA Icing Research Tunnel. A main component of the program was the geometric assessment of the 3- D laser scanning system on a 2-D (straight wing) and a 3-D (swept wing) airfoil geometries. This exercise consisted of comparison of scanned ice accretion to castings of the same ice accretion. The scan data were also used to create rapid prototype artificial ice shapes that were scanned and compared to the original ice accretion. The results from geometric comparisons on the straight wing showed that the ice shape models generated through the scan/rapid prototype process compared reasonably well with the cast shapes. Similar results were obtained with the geometric comparisons on the swept wing. It was difficult to precisely compare the scans of the cast shapes to the original ice accretion scans because the cast shapes appear to have shrunk during the mold/casting process by as much as 0.10-inch. However the comparison of the local ice-shape features were possible and produced better results. The rapid prototype manufacturing process was shown to reproduce the original ice accretion scan normally within 0.01-inch.

  8. Implementation and Validation of 3-D Ice Accretion Measurement Methodology

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Broeren, Andy; Kreeger, Richard; Potapczuk, Mark; Utt, Lloyd

    2014-01-01

    A research program has been implemented to develop and validate the use of a commercial 3-D laser scanning system to record ice accretion geometry in the NASA Icing Research Tunnel. A main component of the program was the geometric assessment of the 3-D laser scanning system on a 2-D (straight wing) and a 3-D (swept wing) airfoil geometries. This exercise consisted of comparison of scanned ice accretion to castings of the same ice accretion. The scan data were also used to create rapid prototype artificial ice shapes that were scanned and compared to the original ice accretion.The results from geometric comparisons on the straight wing showed that the ice shape models generated through the scanrapid prototype process compared reasonably well with the cast shapes. Similar results were obtained with the geometric comparisons on the swept wing. It was difficult to precisely compare the scans of the cast shapes to the original ice accretion scans because the cast shapes appear to have shrunk during the moldcasting process by as much as 0.10-inch. However the comparison of the local ice-shape features were possible and produced better results. The rapid prototype manufacturing process was shown to reproduce the original ice accretion scan normally within 0.01-inch.

  9. A computational model that recovers the 3D shape of an object from a single 2D retinal representation.

    PubMed

    Li, Yunfeng; Pizlo, Zygmunt; Steinman, Robert M

    2009-05-01

    Human beings perceive 3D shapes veridically, but the underlying mechanisms remain unknown. The problem of producing veridical shape percepts is computationally difficult because the 3D shapes have to be recovered from 2D retinal images. This paper describes a new model, based on a regularization approach, that does this very well. It uses a new simplicity principle composed of four shape constraints: viz., symmetry, planarity, maximum compactness and minimum surface. Maximum compactness and minimum surface have never been used before. The model was tested with random symmetrical polyhedra. It recovered their 3D shapes from a single randomly-chosen 2D image. Neither learning, nor depth perception, was required. The effectiveness of the maximum compactness and the minimum surface constraints were measured by how well the aspect ratio of the 3D shapes was recovered. These constraints were effective; they recovered the aspect ratio of the 3D shapes very well. Aspect ratios recovered by the model were compared to aspect ratios adjusted by four human observers. They also adjusted aspect ratios very well. In those rare cases, in which the human observers showed large errors in adjusted aspect ratios, their errors were very similar to the errors made by the model. PMID:18621410

  10. New approach to the perception of 3D shape based on veridicality, complexity, symmetry and volume.

    PubMed

    Pizlo, Zygmunt; Sawada, Tadamasa; Li, Yunfeng; Kropatsch, Walter G; Steinman, Robert M

    2010-01-01

    This paper reviews recent progress towards understanding 3D shape perception made possible by appreciating the significant role that veridicality and complexity play in the natural visual environment. The ability to see objects as they really are "out there" is derived from the complexity inherent in the 3D object's shape. The importance of both veridicality and complexity was ignored in most prior research. Appreciating their importance made it possible to devise a computational model that recovers the 3D shape of an object from only one of its 2D images. This model uses a simplicity principle consisting of only four a priori constraints representing properties of 3D shapes, primarily their symmetry and volume. The model recovers 3D shapes from a single 2D image as well, and sometimes even better, than a human being. In the rare recoveries in which errors are observed, the errors made by the model and human subjects are very similar. The model makes no use of depth, surfaces or learning. Recent elaborations of this model include: (i) the recovery of the shapes of natural objects, including human and animal bodies with limbs in varying positions (ii) providing the model with two input images that allowed it to achieve virtually perfect shape constancy from almost all viewing directions. The review concludes with a comparison of some of the highlights of our novel, successful approach to the recovery of 3D shape from a 2D image with prior, less successful approaches. PMID:19800910

  11. The Extraction of 3D Shape from Texture and Shading in the Human Brain

    PubMed Central

    Georgieva, Svetlana S.; Todd, James T.; Peeters, Ronald

    2008-01-01

    We used functional magnetic resonance imaging to investigate the human cortical areas involved in processing 3-dimensional (3D) shape from texture (SfT) and shading. The stimuli included monocular images of randomly shaped 3D surfaces and a wide variety of 2-dimensional (2D) controls. The results of both passive and active experiments reveal that the extraction of 3D SfT involves the bilateral caudal inferior temporal gyrus (caudal ITG), lateral occipital sulcus (LOS) and several bilateral sites along the intraparietal sulcus. These areas are largely consistent with those involved in the processing of 3D shape from motion and stereo. The experiments also demonstrate, however, that the analysis of 3D shape from shading is primarily restricted to the caudal ITG areas. Additional results from psychophysical experiments reveal that this difference in neuronal substrate cannot be explained by a difference in strength between the 2 cues. These results underscore the importance of the posterior part of the lateral occipital complex for the extraction of visual 3D shape information from all depth cues, and they suggest strongly that the importance of shading is diminished relative to other cues for the analysis of 3D shape in parietal regions. PMID:18281304

  12. Development of 3-D Ice Accretion Measurement Method

    NASA Technical Reports Server (NTRS)

    Lee, Sam; Broeren, Andy P.; Addy, Harold E., Jr.; Sills, Robert; Pifer, Ellen M.

    2012-01-01

    A research plan is currently being implemented by NASA to develop and validate the use of a commercial laser scanner to record and archive fully three-dimensional (3-D) ice shapes from an icing wind tunnel. The plan focused specifically upon measuring ice accreted in the NASA Icing Research Tunnel (IRT). The plan was divided into two phases. The first phase was the identification and selection of the laser scanning system and the post-processing software to purchase and develop further. The second phase was the implementation and validation of the selected system through a series of icing and aerodynamic tests. Phase I of the research plan has been completed. It consisted of evaluating several scanning hardware and software systems against an established selection criteria through demonstrations in the IRT. The results of Phase I showed that all of the scanning systems that were evaluated were equally capable of scanning ice shapes. The factors that differentiated the scanners were ease of use and the ability to operate in a wide range of IRT environmental conditions.

  13. Experimental and Numerical Investigation of Forging Process to Reproduce a 3D Aluminium Foam Complex Shape

    SciTech Connect

    Filice, Luigino; Gagliardi, Francesco; Umbrello, Domenico; Shivpuri, Rajiv

    2007-05-17

    Metallic foams represent one of the most exciting materials introduced in the manufacturing scenario in the last years. In the study here addressed, the experimental and numerical investigations on the forging process of a simple foam billet shaped into complex sculptured parts were carried out. In particular, the deformation behavior of metallic foams and the development of density gradients were investigated through a series of experimental forging tests in order to produce a selected portion of a hip prosthesis. The human bone replacement was chosen as case study due to its industrial demand and for its particular 3D complex shape. A finite element code (Deform 3D) was utilized for modeling the foam behavior during the forging process and an accurate material rheology description was used based on a porous material model which includes the measured local density. Once the effectiveness of the utilized Finite Element model was verified through the comparison with the experimental evidences, a numerical study of the influence of the foam density was investigated. The obtained numerical results shown as the initial billet density plays an important role on the prediction of the final shape, the optimization of the flash as well as the estimation of the punch load.

  14. 3D model retrieval using probability density-based shape descriptors.

    PubMed

    Akgül, Ceyhun Burak; Sankur, Bülent; Yemez, Yücel; Schmitt, Francis

    2009-06-01

    We address content-based retrieval of complete 3D object models by a probabilistic generative description of local shape properties. The proposed shape description framework characterizes a 3D object with sampled multivariate probability density functions of its local surface features. This density-based descriptor can be efficiently computed via kernel density estimation (KDE) coupled with fast Gauss transform. The non-parametric KDE technique allows reliable characterization of a diverse set of shapes and yields descriptors which remain relatively insensitive to small shape perturbations and mesh resolution. Density-based characterization also induces a permutation property which can be used to guarantee invariance at the shape matching stage. As proven by extensive retrieval experiments on several 3D databases, our framework provides state-of-the-art discrimination over a broad and heterogeneous set of shape categories. PMID:19372614

  15. The ATLAS 3D project - XXIV. The intrinsic shape distribution of early-type galaxies

    NASA Astrophysics Data System (ADS)

    Weijmans, Anne-Marie; de Zeeuw, P. T.; Emsellem, Eric; Krajnović, Davor; Lablanche, Pierre-Yves; Alatalo, Katherine; Blitz, Leo; Bois, Maxime; Bournaud, Frédéric; Bureau, Martin; Cappellari, Michele; Crocker, Alison F.; Davies, Roger L.; Davis, Timothy A.; Duc, Pierre-Alain; Khochfar, Sadegh; Kuntschner, Harald; McDermid, Richard M.; Morganti, Raffaella; Naab, Thorsten; Oosterloo, Tom; Sarzi, Marc; Scott, Nicholas; Serra, Paolo; Verdoes Kleijn, Gijs; Young, Lisa M.

    2014-11-01

    We use the ATLAS3D sample to perform a study of the intrinsic shapes of early-type galaxies, taking advantage of the available combined photometric and kinematic data. Based on our ellipticity measurements from the Sloan Digital Sky Survey Data Release 7, and additional imaging from the Isaac Newton Telescope, we first invert the shape distribution of fast and slow rotators under the assumption of axisymmetry. The so-obtained intrinsic shape distribution for the fast rotators can be described with a Gaussian with a mean flattening of q = 0.25 and standard deviation σq = 0.14, and an additional tail towards rounder shapes. The slow rotators are much rounder, and are well described with a Gaussian with mean q = 0.63 and σq = 0.09. We then checked that our results were consistent when applying a different and independent method to obtain intrinsic shape distributions, by fitting the observed ellipticity distributions directly using Gaussian parametrizations for the intrinsic axis ratios. Although both fast and slow rotators are identified as early-type galaxies in morphological studies, and in many previous shape studies are therefore grouped together, their shape distributions are significantly different, hinting at different formation scenarios. The intrinsic shape distribution of the fast rotators shows similarities with the spiral galaxy population. Including the observed kinematic misalignment in our intrinsic shape study shows that the fast rotators are predominantly axisymmetric, with only very little room for triaxiality. For the slow rotators though there are very strong indications that they are (mildly) triaxial.

  16. Accommodation response measurements for integral 3D image

    NASA Astrophysics Data System (ADS)

    Hiura, H.; Mishina, T.; Arai, J.; Iwadate, Y.

    2014-03-01

    We measured accommodation responses under integral photography (IP), binocular stereoscopic, and real object display conditions, and viewing conditions of binocular and monocular viewing conditions. The equipment we used was an optometric device and a 3D display. We developed the 3D display for IP and binocular stereoscopic images that comprises a high-resolution liquid crystal display (LCD) and a high-density lens array. The LCD has a resolution of 468 dpi and a diagonal size of 4.8 inches. The high-density lens array comprises 106 x 69 micro lenses that have a focal length of 3 mm and diameter of 1 mm. The lenses are arranged in a honeycomb pattern. The 3D display was positioned 60 cm from an observer under IP and binocular stereoscopic display conditions. The target was presented at eight depth positions relative to the 3D display: 15, 10, and 5 cm in front of the 3D display, on the 3D display panel, and 5, 10, 15 and 30 cm behind the 3D display under the IP and binocular stereoscopic display conditions. Under the real object display condition, the target was displayed on the 3D display panel, and the 3D display was placed at the eight positions. The results suggest that the IP image induced more natural accommodation responses compared to the binocular stereoscopic image. The accommodation responses of the IP image were weaker than those of a real object; however, they showed a similar tendency with those of the real object under the two viewing conditions. Therefore, IP can induce accommodation to the depth positions of 3D images.

  17. 3D Printed Reversible Shape Changing Components with Stimuli Responsive Materials.

    PubMed

    Mao, Yiqi; Ding, Zhen; Yuan, Chao; Ai, Shigang; Isakov, Michael; Wu, Jiangtao; Wang, Tiejun; Dunn, Martin L; Qi, H Jerry

    2016-01-01

    The creation of reversibly-actuating components that alter their shapes in a controllable manner in response to environmental stimuli is a grand challenge in active materials, structures, and robotics. Here we demonstrate a new reversible shape-changing component design concept enabled by 3D printing two stimuli responsive polymers-shape memory polymers and hydrogels-in prescribed 3D architectures. This approach uses the swelling of a hydrogel as the driving force for the shape change, and the temperature-dependent modulus of a shape memory polymer to regulate the time of such shape change. Controlling the temperature and aqueous environment allows switching between two stable configurations - the structures are relatively stiff and can carry load in each - without any mechanical loading and unloading. Specific shape changing scenarios, e.g., based on bending, or twisting in prescribed directions, are enabled via the controlled interplay between the active materials and the 3D printed architectures. The physical phenomena are complex and nonintuitive, and so to help understand the interplay of geometric, material, and environmental stimuli parameters we develop 3D nonlinear finite element models. Finally, we create several 2D and 3D shape changing components that demonstrate the role of key parameters and illustrate the broad application potential of the proposed approach. PMID:27109063

  18. 3D Printed Reversible Shape Changing Components with Stimuli Responsive Materials

    PubMed Central

    Mao, Yiqi; Ding, Zhen; Yuan, Chao; Ai, Shigang; Isakov, Michael; Wu, Jiangtao; Wang, Tiejun; Dunn, Martin L.; Qi, H. Jerry

    2016-01-01

    The creation of reversibly-actuating components that alter their shapes in a controllable manner in response to environmental stimuli is a grand challenge in active materials, structures, and robotics. Here we demonstrate a new reversible shape-changing component design concept enabled by 3D printing two stimuli responsive polymers—shape memory polymers and hydrogels—in prescribed 3D architectures. This approach uses the swelling of a hydrogel as the driving force for the shape change, and the temperature-dependent modulus of a shape memory polymer to regulate the time of such shape change. Controlling the temperature and aqueous environment allows switching between two stable configurations – the structures are relatively stiff and can carry load in each – without any mechanical loading and unloading. Specific shape changing scenarios, e.g., based on bending, or twisting in prescribed directions, are enabled via the controlled interplay between the active materials and the 3D printed architectures. The physical phenomena are complex and nonintuitive, and so to help understand the interplay of geometric, material, and environmental stimuli parameters we develop 3D nonlinear finite element models. Finally, we create several 2D and 3D shape changing components that demonstrate the role of key parameters and illustrate the broad application potential of the proposed approach. PMID:27109063

  19. 3D Printed Reversible Shape Changing Components with Stimuli Responsive Materials

    NASA Astrophysics Data System (ADS)

    Mao, Yiqi; Ding, Zhen; Yuan, Chao; Ai, Shigang; Isakov, Michael; Wu, Jiangtao; Wang, Tiejun; Dunn, Martin L.; Qi, H. Jerry

    2016-04-01

    The creation of reversibly-actuating components that alter their shapes in a controllable manner in response to environmental stimuli is a grand challenge in active materials, structures, and robotics. Here we demonstrate a new reversible shape-changing component design concept enabled by 3D printing two stimuli responsive polymers—shape memory polymers and hydrogels—in prescribed 3D architectures. This approach uses the swelling of a hydrogel as the driving force for the shape change, and the temperature-dependent modulus of a shape memory polymer to regulate the time of such shape change. Controlling the temperature and aqueous environment allows switching between two stable configurations – the structures are relatively stiff and can carry load in each – without any mechanical loading and unloading. Specific shape changing scenarios, e.g., based on bending, or twisting in prescribed directions, are enabled via the controlled interplay between the active materials and the 3D printed architectures. The physical phenomena are complex and nonintuitive, and so to help understand the interplay of geometric, material, and environmental stimuli parameters we develop 3D nonlinear finite element models. Finally, we create several 2D and 3D shape changing components that demonstrate the role of key parameters and illustrate the broad application potential of the proposed approach.

  20. The 3D EdgeRunner Pipeline: a novel shape-based analysis for neoplasms characterization

    NASA Astrophysics Data System (ADS)

    Yepes-C, Fernando; Johnson, Rebecca; Lao, Yi; Hwang, Darryl; Coloigner, Julie; Yap, Felix; Bushan, Desai; Cheng, Phillip; Gill, Inderbir; Duddalwar, Vinay; Lepore, Natasha

    2016-03-01

    The characterization of tumors after being imaged is currently a qualitative process performed by skilled professionals. If we can aid their diagnosis by identifying quantifiable features associated with tumor classification, we may avoid invasive procedures such as biopsies and enhance efficiency. The aim of this paper is to describe the 3D EdgeRunner Pipeline which characterizes the shape of a tumor. Shape analysis is relevant as malignant tumors tend to be more lobular and benign ones tare generally more symmetrical. The method described considers the distance from each point on the edge of the tumor to the centre of a synthetically created field of view. The method then determines coordinates where the measured distances are rapidly changing (peaks) using a second derivative found by five point differentiation. The list of coordinates considered to be peaks can then be used as statistical data to compare tumors quantitatively. We have found this process effectively captures the peaks on a selection of kidney tumors.

  1. 3D shape analysis for early diagnosis of malignant lung nodules.

    PubMed

    El-Baz, Ayman; Nitzken, Matthew; Elnakib, Ahmed; Khalifa, Fahmi; Gimel'farb, Georgy; Falk, Robert; El-Ghar, Mohamed Abou

    2011-01-01

    An alternative method of diagnosing malignant lung nodules by their shape, rather than conventional growth rate, is proposed. The 3D surfaces of the detected lung nodules are delineated by spherical harmonic analysis that represents a 3D surface of the lung nodule supported by the unit sphere with a linear combination of special basis functions, called Spherical Harmonics (SHs). The proposed 3D shape analysis is carried out in five steps: (i) 3D lung nodule segmentation with a deformable 3D boundary controlled by a new prior visual appearance model; (ii) 3D Delaunay triangulation to construct a 3D mesh model of the segmented lung nodule surface; (iii) mapping this model to the unit sphere; (iv) computing the SHs for the surface; and (v) determining the number of the SHs to delineate the lung nodule. We describe the lung nodule shape complexity with a new shape index, the estimated number of the SHs, and use it for the K-nearest classification into malignant and benign lung nodules. Preliminary experiments on 327 lung nodules (153 malignant and 174 benign) resulted in a classification accuracy of 93.6%, showing that the proposed method is a promising supplement to current technologies for the early diagnosis of lung cancer. PMID:22003697

  2. 3D shape analysis for early diagnosis of malignant lung nodules.

    PubMed

    El-Bazl, Ayman; Nitzken, Matthew; Khalifa, Fahmi; Elnakib, Ahmed; Gimel'farb, Georgy; Falk, Robert; El-Ghar, Mohammed Abo

    2011-01-01

    An alternative method for diagnosing malignant lung nodules by their shape rather than conventional growth rate is proposed. The 3D surfaces of the detected lung nodules are delineated by spherical harmonic analysis, which represents a 3D surface of the lung nodule supported by the unit sphere with a linear combination of special basis functions, called spherical harmonics (SHs). The proposed 3D shape analysis is carried out in five steps: (i) 3D lung nodule segmentation with a deformable 3D boundary controlled by two probabilistic visual appearance models (the learned prior and the estimated current appearance one); (ii) 3D Delaunay triangulation to construct a 3D mesh model of the segmented lung nodule surface; (iii) mapping this model to the unit sphere; (iv) computing the SHs for the surface, and (v) determining the number of the SHs to delineate the lung nodule. We describe the lung nodule shape complexity with a new shape index, the estimated number of the SHs, and use it for the K-nearest classification to distinguish malignant and benign lung nodules. Preliminary experiments on 327 lung nodules (153 malignant and 174 benign) resulted in the 93.6% correct classification (for the 95% confidence interval), showing that the proposed method is a promising supplement to current technologies for the early diagnosis of lung cancer. PMID:21761703

  3. 3D-profile measurement of advanced semiconductor features by reference metrology

    NASA Astrophysics Data System (ADS)

    Takamasu, Kiyoshi; Iwaki, Yuuki; Takahashi, Satoru; Kawada, Hiroki; Ikota, Masami; Lorusso, Gian F.; Horiguchi, Naoto

    2016-03-01

    A method of sub-nanometer uncertainty for the 3D-profile measurement using TEM (Transmission Electron Microscope) images is proposed to standardize 3D-profile measurement through reference metrology. The proposed method has been validated for profiles of Si lines, photoresist features and advanced-FinFET (Fin-shaped Field-Effect Transistor) features in our previous investigations. However, efficiency of 3D-profile measurement using TEM is limited by measurement time including processing of the sample. In this article, we demonstrate a novel on-wafer 3D-profile metrology as "FIB-to-CDSEM method" with FIB (Focused Ion Beam) slope cut and CD-SEM (Critical Dimension Secondary Electron Microscope) measuring. Using the method, a few micrometer wide on a wafer is coated and cut by 45 degree slope using FIB tool. Then, the wafer is transferred to CD-SEM to measure the cross section image by top down CD-SEM measurement. We apply FIB-to-CDSEM method to CMOS sensor device. 3D-profile and 3D-profile parameters such as top line width and side wall angles of CMOS sensor device are evaluated. The 3D-profile parameters also are measured by TEM images as reference metrology. We compare the 3D-profile parameters by TEM method and FIB-to-CDSEM method. The average values and correlations on the wafer are agreed well between TEM and FIB-to- CDSEM methods.

  4. Classification and quantification of pore shapes in sandstone reservoir rocks with 3-D X-ray micro-computed tomography

    NASA Astrophysics Data System (ADS)

    Schmitt, M.; Halisch, M.; Müller, C.; Fernandes, C. P.

    2015-12-01

    Recent years have seen a growing interest in the characterization of the pore morphologies of reservoir rocks and how the spatial organization of pore traits affects the macro behaviour of rock-fluid systems. With the availability of 3-D high-resolution imaging (e.g. μ-CT), the detailed quantification of particle shapes has been facilitated by progress in computer science. Here, we show how the shapes of irregular rock particles (pores) can be classified and quantified based on binary 3-D images. The methodology requires the measurement of basic 3-D particle descriptors and a shape classification that involves the similarity of artificial objects, which is based on main pore network detachments and 3-D sample sizes. The results were validated for three sandstones (S1, S2 and S3) from distinct reservoirs, and most of the pore shapes were found to be plate- and cube-like. Furthermore, this study generalizes a practical way to correlate specific particle shapes, such as rods, blades, cuboids, plates and cubes, to characterize asymmetric particles of any material type with 3-D image analysis.

  5. Shape Analysis of 3D Head Scan Data for U.S. Respirator Users

    NASA Astrophysics Data System (ADS)

    Zhuang, Ziqing; Slice, DennisE; Benson, Stacey; Lynch, Stephanie; Viscusi, DennisJ

    2010-12-01

    In 2003, the National Institute for Occupational Safety and Health (NIOSH) conducted a head-and-face anthropometric survey of diverse, civilian respirator users. Of the 3,997 subjects measured using traditional anthropometric techniques, surface scans and 26 three-dimensional (3D) landmark locations were collected for 947 subjects. The objective of this study was to report the size and shape variation of the survey participants using the 3D data. Generalized Procrustes Analysis (GPA) was conducted to standardize configurations of landmarks associated with individuals into a common coordinate system. The superimposed coordinates for each individual were used as commensurate variables that describe individual shape and were analyzed using Principal Component Analysis (PCA) to identify population variation. The first four principal components (PC) account for 49% of the total sample variation. The first PC indicates that overall size is an important component of facial variability. The second PC accounts for long and narrow or short and wide faces. Longer narrow orbits versus shorter wider orbits can be described by PC3, and PC4 represents variation in the degree of ortho/prognathism. Geometric Morphometrics provides a detailed and interpretable assessment of morphological variation that may be useful in assessing respirators and devising new test and certification standards.

  6. Robust Detection of Round Shaped Pits Lying on 3D Meshes: Application to Impact Crater Recognition

    NASA Astrophysics Data System (ADS)

    Schmidt, Martin-Pierre; Muscato, Jennifer; Viseur, Sophie; Jorda, Laurent; Bouley, Sylvain; Mari, Jean-Luc

    2015-04-01

    Most celestial bodies display impacts of collisions with asteroids and meteoroids. These traces are called craters. The possibility of observing and identifying these craters and their characteristics (radius, depth and morphology) is the only method available to measure the age of different units at the surface of the body, which in turn allows to constrain its conditions of formation. Interplanetary space probes always carry at least one imaging instrument on board. The visible images of the target are used to reconstruct high-resolution 3D models of its surface as a cloud of points in the case of multi-image dense stereo, or as a triangular mesh in the case of stereo and shape-from-shading. The goal of this work is to develop a methodology to automatically detect the craters lying on these 3D models. The robust extraction of feature areas on surface objects embedded in 3D, like circular pits, is a challenging problem. Classical approaches generally rely on image processing and template matching on a 2D flat projection of the 3D object (i.e.: a high-resolution photograph). In this work, we propose a full-3D method that mainly relies on curvature analysis. Mean and Gaussian curvatures are estimated on the surface. They are used to label vertices that belong to concave parts corresponding to specific pits on the surface. The surface is thus transformed into binary map distinguishing potential crater features to other types of features. Centers are located in the targeted surface regions, corresponding to potential crater features. Concentric rings are then built around the found centers. They consist in circular closed lines exclusively composed of edges of the initial mesh. The first built ring represents the nearest vertex neighborhood of the found center. The ring is then optimally expanded using a circularity constrain and the curvature values of the ring vertices. This method has been tested on a 3D model of the asteroid Lutetia observed by the ROSETTA (ESA

  7. Recovering 3D Shape with Absolute Size from Endoscope Images Using RBF Neural Network

    PubMed Central

    Tsuda, Seiya; Iwahori, Yuji; Bhuyan, M. K.; Woodham, Robert J.; Kasugai, Kunio

    2015-01-01

    Medical diagnosis judges the status of polyp from the size and the 3D shape of the polyp from its medical endoscope image. However the medical doctor judges the status empirically from the endoscope image and more accurate 3D shape recovery from its 2D image has been demanded to support this judgment. As a method to recover 3D shape with high speed, VBW (Vogel-Breuß-Weickert) model is proposed to recover 3D shape under the condition of point light source illumination and perspective projection. However, VBW model recovers the relative shape but there is a problem that the shape cannot be recovered with the exact size. Here, shape modification is introduced to recover the exact shape with modification from that with VBW model. RBF-NN is introduced for the mapping between input and output. Input is given as the output of gradient parameters of VBW model for the generated sphere. Output is given as the true gradient parameters of true values of the generated sphere. Learning mapping with NN can modify the gradient and the depth can be recovered according to the modified gradient parameters. Performance of the proposed approach is confirmed via computer simulation and real experiment. PMID:25949235

  8. Simultaneous acquisition of 3D shape and deformation by combination of interferometric and correlation-based laser speckle metrology

    PubMed Central

    Dekiff, Markus; Berssenbrügge, Philipp; Kemper, Björn; Denz, Cornelia; Dirksen, Dieter

    2015-01-01

    A metrology system combining three laser speckle measurement techniques for simultaneous determination of 3D shape and micro- and macroscopic deformations is presented. While microscopic deformations are determined by a combination of Digital Holographic Interferometry (DHI) and Digital Speckle Photography (DSP), macroscopic 3D shape, position and deformation are retrieved by photogrammetry based on digital image correlation of a projected laser speckle pattern. The photogrammetrically obtained data extend the measurement range of the DHI-DSP system and also increase the accuracy of the calculation of the sensitivity vector. Furthermore, a precise assignment of microscopic displacements to the object’s macroscopic shape for enhanced visualization is achieved. The approach allows for fast measurements with a simple setup. Key parameters of the system are optimized, and its precision and measurement range are demonstrated. As application examples, the deformation of a mandible model and the shrinkage of dental impression material are measured. PMID:26713197

  9. Simultaneous acquisition of 3D shape and deformation by combination of interferometric and correlation-based laser speckle metrology.

    PubMed

    Dekiff, Markus; Berssenbrügge, Philipp; Kemper, Björn; Denz, Cornelia; Dirksen, Dieter

    2015-12-01

    A metrology system combining three laser speckle measurement techniques for simultaneous determination of 3D shape and micro- and macroscopic deformations is presented. While microscopic deformations are determined by a combination of Digital Holographic Interferometry (DHI) and Digital Speckle Photography (DSP), macroscopic 3D shape, position and deformation are retrieved by photogrammetry based on digital image correlation of a projected laser speckle pattern. The photogrammetrically obtained data extend the measurement range of the DHI-DSP system and also increase the accuracy of the calculation of the sensitivity vector. Furthermore, a precise assignment of microscopic displacements to the object's macroscopic shape for enhanced visualization is achieved. The approach allows for fast measurements with a simple setup. Key parameters of the system are optimized, and its precision and measurement range are demonstrated. As application examples, the deformation of a mandible model and the shrinkage of dental impression material are measured. PMID:26713197

  10. Large bulk-yard 3D measurement based on videogrammetry and projected contour aiding

    NASA Astrophysics Data System (ADS)

    Ou, Jianliang; Zhang, Xiaohu; Yuan, Yun; Zhu, Xianwei

    2011-07-01

    Fast and accurate 3D measurement of large stack-yard is important job in bulk load-and-unload and logistics management. Stack-yard holds its special characteristics as: complex and irregular shape, single surface texture and low material reflectivity, thus its 3D measurement is quite difficult to be realized by traditional non-contacting methods, such as LiDAR(LIght Detecting And Ranging) and photogrammetry. Light-section is good at the measurement of small bulk-flow but not suitable for large-scale bulk-yard yet. In the paper, an improved method based on stereo cameras and laser-line projector is proposed. The due theoretical model is composed from such three key points: corresponding point of contour edge matching in stereo imagery based on gradient and epipolar-line constraint, 3D point-set calculating for stereo imagery projected-contour edge with least square adjustment and forward intersection, then the projected 3D-contour reconstructed by RANSAC(RANdom SAmpling Consensus) and contour spatial features from 3D point-set of single contour edge. In this way, stack-yard surface can be scanned easily by the laser-line projector, and certain region's 3D shape can be reconstructed automatically by stereo cameras on an observing position. Experiment proved the proposed method is effective for bulk-yard 3D measurement in fast, automatic, reliable and accurate way.

  11. The numerical measure of symmetry for 3D stick creatures.

    PubMed

    Jaśkowski, Wojciech; Komosinski, Maciej

    2008-01-01

    This work introduces a numerical, continuous measure of symmetry for 3D stick creatures and solid 3D objects. Background information about the property of symmetry is provided, and motivations for developing a symmetry measure are described. Three approaches are mentioned, and two of them are presented in detail using formal mathematical language. The best approach is used to sort a set of creatures according to their symmetry. Experiments with a mixed set of 84 individuals originating from both human design and evolution are performed to examine symmetry within these two sources, and to determine if human designers and evolutionary processes prefer symmetry or asymmetry. PMID:18573069

  12. Embodied collaboration support system for 3D shape evaluation in virtual space

    NASA Astrophysics Data System (ADS)

    Okubo, Masashi; Watanabe, Tomio

    2005-12-01

    Collaboration mainly consists of two tasks; one is each partner's task that is performed by the individual, the other is communication with each other. Both of them are very important objectives for all the collaboration support system. In this paper, a collaboration support system for 3D shape evaluation in virtual space is proposed on the basis of both studies in 3D shape evaluation and communication support in virtual space. The proposed system provides the two viewpoints for each task. One is the viewpoint of back side of user's own avatar for the smooth communication. The other is that of avatar's eye for 3D shape evaluation. Switching the viewpoints satisfies the task conditions for 3D shape evaluation and communication. The system basically consists of PC, HMD and magnetic sensors, and users can share the embodied interaction by observing interaction between their avatars in virtual space. However, the HMD and magnetic sensors, which are put on the users, would restrict the nonverbal communication. Then, we have tried to compensate the loss of nodding of partner's avatar by introducing the speech-driven embodied interactive actor InterActor. Sensory evaluation by paired comparison of 3D shapes in the collaborative situation in virtual space and in real space and the questionnaire are performed. The result demonstrates the effectiveness of InterActor's nodding in the collaborative situation.

  13. 3D precision surface measurement by dynamic structured light

    NASA Astrophysics Data System (ADS)

    Franke, Ernest A.; Magee, Michael J.; Mitchell, Joseph N.; Rigney, Michael P.

    2004-02-01

    This paper describes a 3-D imaging technique developed as an internal research project at Southwest Research Institute. The technique is based on an extension of structured light methods in which a projected pattern of parallel lines is rotated over the surface to be measured. A sequence of images is captured and the surface elevation at any location can then be determined from measurements of the temporal pattern, at any point, without considering any other points on the surface. The paper describes techniques for system calibration and surface measurement based on the method of projected quadric shells. Algorithms were developed for image and signal analysis and computer programs were written to calibrate the system and to calculate 3-D coordinates of points on a measured surface. A prototype of the Dynamic Structured Light (DSL) 3-D imaging system was assembled and typical parts were measured. The design procedure was verified and used to implement several different configurations with different measurement volumes and measurement accuracy. A small-parts measurement accuracy of 32 micrometers (.0012") RMS was verified by measuring the surface of a precision-machined plane. Large aircraft control surfaces were measured with a prototype setup that provided .02" depth resolution over a 4" by 8" field of view. Measurement times are typically less than three minutes for 300,000 points. A patent application has been filed.

  14. A channel for 3D environmental shape in anterior inferotemporal cortex

    PubMed Central

    Vaziri, Siavash; Carlson, Eric T.; Wang, Zhihong; Connor, Charles E.

    2014-01-01

    SUMMARY Inferotemporal cortex (IT) has long been studied as a single pathway dedicated to object vision, but connectivity analysis reveals anatomically distinct channels, through ventral superior temporal sulcus (STSv) and dorsal/ventral inferotemporal gyrus (TEd, TEv). Here, we report a major functional distinction between channels. We studied individual IT neurons in monkeys viewing stereoscopic 3D images projected on a large screen. We used adaptive stimuli to explore neural tuning for 3D abstract shapes ranging in scale and topology from small, closed, bounded objects to large, open, unbounded environments (landscape-like surfaces and cave-like interiors). In STSv, most neurons were more responsive to objects, as expected. In TEd, surprisingly, most neurons were more responsive to 3D environmental shape. Previous studies have localized environmental information to posterior cortical modules. Our results show it is also channeled through anterior IT, where extensive cross-connections between STSv and TEd could integrate object and environmental shape information. PMID:25242216

  15. Measuring Knowledge Acquisition in 3D Virtual Learning Environments.

    PubMed

    Nunes, Eunice P dos Santos; Roque, Licínio G; Nunes, Fatima de Lourdes dos Santos

    2016-01-01

    Virtual environments can contribute to the effective learning of various subjects for people of all ages. Consequently, they assist in reducing the cost of maintaining physical structures of teaching, such as laboratories and classrooms. However, the measurement of how learners acquire knowledge in such environments is still incipient in the literature. This article presents a method to evaluate the knowledge acquisition in 3D virtual learning environments (3D VLEs) by using the learner's interactions in the VLE. Three experiments were conducted that demonstrate the viability of using this method and its computational implementation. The results suggest that it is possible to automatically assess learning in predetermined contexts and that some types of user interactions in 3D VLEs are correlated with the user's learning differential. PMID:26915117

  16. Shape and 3D acoustically induced vibrations of the human eardrum characterized by digital holography

    NASA Astrophysics Data System (ADS)

    Khaleghi, Morteza; Furlong, Cosme; Cheng, Jeffrey Tao; Rosowski, John J.

    2014-07-01

    The eardrum or Tympanic Membrane (TM) transfers acoustic energy from the ear canal (at the external ear) into mechanical motions of the ossicles (at the middle ear). The acousto-mechanical-transformer behavior of the TM is determined by its shape and mechanical properties. For a better understanding of hearing mysteries, full-field-of-view techniques are required to quantify shape, nanometer-scale sound-induced displacement, and mechanical properties of the TM in 3D. In this paper, full-field-of-view, three-dimensional shape and sound-induced displacement of the surface of the TM are obtained by the methods of multiple wavelengths and multiple sensitivity vectors with lensless digital holography. Using our developed digital holographic systems, unique 3D information such as, shape (with micrometer resolution), 3D acoustically-induced displacement (with nanometer resolution), full strain tensor (with nano-strain resolution), 3D phase of motion, and 3D directional cosines of the displacement vectors can be obtained in full-field-ofview with a spatial resolution of about 3 million points on the surface of the TM and a temporal resolution of 15 Hz.

  17. Statistical 3D shape analysis of gender differences in lateral ventricles

    NASA Astrophysics Data System (ADS)

    He, Qing; Karpman, Dmitriy; Duan, Ye

    2010-03-01

    This paper aims at analyzing gender differences in the 3D shapes of lateral ventricles, which will provide reference for the analysis of brain abnormalities related to neurological disorders. Previous studies mostly focused on volume analysis, and the main challenge in shape analysis is the required step of establishing shape correspondence among individual shapes. We developed a simple and efficient method based on anatomical landmarks. 14 females and 10 males with matching ages participated in this study. 3D ventricle models were segmented from MR images by a semiautomatic method. Six anatomically meaningful landmarks were identified by detecting the maximum curvature point in a small neighborhood of a manually clicked point on the 3D model. Thin-plate spline was used to transform a randomly selected template shape to each of the rest shape instances, and the point correspondence was established according to Euclidean distance and surface normal. All shapes were spatially aligned by Generalized Procrustes Analysis. Hotelling T2 twosample metric was used to compare the ventricle shapes between males and females, and False Discovery Rate estimation was used to correct for the multiple comparison. The results revealed significant differences in the anterior horn of the right ventricle.

  18. Experimental and Numerical Investigation of Forging Process to Reproduce a 3D Aluminium Foam Complex Shape

    NASA Astrophysics Data System (ADS)

    Filice, Luigino; Gagliardi, Francesco; Shivpuri, Rajiv; Umbrello, Domenico

    2007-05-01

    Metallic foams represent one of the most exciting materials introduced in the manufacturing scenario in the last years. In the study here addressed, the experimental and numerical investigations on the forging process of a simple foam billet shaped into complex sculptured parts were carried out. In particular, the deformation behavior of metallic foams and the development of density gradients were investigated through a series of experimental forging tests in order to produce a selected portion of a hip prosthesis. The human bone replacement was chosen as case study due to its industrial demand and for its particular 3D complex shape. A finite element code (Deform 3D®) was utilized for modeling the foam behavior during the forging process and an accurate material rheology description was used based on a porous material model which includes the measured local density. Once the effectiveness of the utilized Finite Element model was verified through the comparison with the experimental evidences, a numerical study of the influence of the foam density was investigated. The obtained numerical results shown as the initial billet density plays an important role on the prediction of the final shape, the optimization of the flash as well as the estimation of the punch load.

  19. Flying triangulation - A motion-robust optical 3D sensor for the real-time shape acquisition of complex objects

    NASA Astrophysics Data System (ADS)

    Willomitzer, Florian; Ettl, Svenja; Arold, Oliver; Häusler, Gerd

    2013-05-01

    The three-dimensional shape acquisition of objects has become more and more important in the last years. Up to now, there are several well-established methods which already yield impressive results. However, even under quite common conditions like object movement or a complex shaping, most methods become unsatisfying. Thus, the 3D shape acquisition is still a difficult and non-trivial task. We present our measurement principle "Flying Triangulation" which enables a motion-robust 3D acquisition of complex-shaped object surfaces by a freely movable handheld sensor. Since "Flying Triangulation" is scalable, a whole sensor-zoo for different object sizes is presented. Concluding, an overview of current and future fields of investigation is given.

  20. Holographic and weak-phase projection system for 3D shape reconstruction using temporal phase unwrapping

    NASA Astrophysics Data System (ADS)

    González, C. A.; Dávila, A.; Garnica, G.

    2007-09-01

    Two projection systems that use an LCoS phase modulator are proposed for 3D shape reconstruction. The LCoS is used as an holographic system or as a weak phase projector, both configurations project a set of fringe patterns that are processed by the technique known as temporal phase unwrapping. To minimize the influence of camera sampling, and the speckle noise in the projected fringes, an speckle noise reduction technique is applied to the speckle patterns generated by the holographic optical system. Experiments with 3D shape reconstruction of ophthalmic mold and other testing specimens show the viability of the proposed techniques.

  1. Measuring the Stellar Halo Velocity Anisotropy With 3D Kinematics

    NASA Astrophysics Data System (ADS)

    Cunningham, Emily C.; Deason, Alis J.; Guhathakurta, Puragra; Rockosi, Constance M.; van der Marel, Roeland P.; Sohn, S. Tony

    2016-08-01

    We present the first measurement of the anisotropy parameter β using 3D kinematic information outside of the solar neighborhood. Our sample consists of 13 Milky Way halo stars with measured proper motions and radial velocities in the line of sight of M31. Proper motions were measured using deep, multi-epoch HST imaging, and radial velocities were measured from Keck II/DEIMOS spectra. We measure β = -0.3-0.9 +0.4, which is consistent with isotropy, and inconsistent with measurements in the solar neighborhood. We suggest that this may be the kinematic signature of a relatively early, massive accretion event, or perhaps several such events.

  2. Feasibility study on 3-D shape analysis of high-aspect-ratio features using through-focus scanning optical microscopy

    PubMed Central

    Attota, Ravi Kiran; Weck, Peter; Kramar, John A.; Bunday, Benjamin; Vartanian, Victor

    2016-01-01

    In-line metrologies currently used in the semiconductor industry are being challenged by the aggressive pace of device scaling and the adoption of novel device architectures. Metrology and process control of three-dimensional (3-D) high-aspect-ratio (HAR) features are becoming increasingly important and also challenging. In this paper we present a feasibility study of through-focus scanning optical microscopy (TSOM) for 3-D shape analysis of HAR features. TSOM makes use of 3-D optical data collected using a conventional optical microscope for 3-D shape analysis. Simulation results of trenches and holes down to the 11 nm node are presented. The ability of TSOM to analyze an array of HAR features or a single isolated HAR feature is also presented. This allows for the use of targets with area over 100 times smaller than that of conventional gratings, saving valuable real estate on the wafers. Indications are that the sensitivity of TSOM may match or exceed the International Technology Roadmap for Semiconductors (ITRS) measurement requirements for the next several years. Both simulations and preliminary experimental results are presented. The simplicity, lowcost, high throughput, and nanometer scale 3-D shape sensitivity of TSOM make it an attractive inspection and process monitoring solution for nanomanufacturing. PMID:27464112

  3. Feasibility study on 3-D shape analysis of high-aspect-ratio features using through-focus scanning optical microscopy.

    PubMed

    Attota, Ravi Kiran; Weck, Peter; Kramar, John A; Bunday, Benjamin; Vartanian, Victor

    2016-07-25

    In-line metrologies currently used in the semiconductor industry are being challenged by the aggressive pace of device scaling and the adoption of novel device architectures. Metrology and process control of three-dimensional (3-D) high-aspect-ratio (HAR) features are becoming increasingly important and also challenging. In this paper we present a feasibility study of through-focus scanning optical microscopy (TSOM) for 3-D shape analysis of HAR features. TSOM makes use of 3-D optical data collected using a conventional optical microscope for 3-D shape analysis. Simulation results of trenches and holes down to the 11 nm node are presented. The ability of TSOM to analyze an array of HAR features or a single isolated HAR feature is also presented. This allows for the use of targets with area over 100 times smaller than that of conventional gratings, saving valuable real estate on the wafers. Indications are that the sensitivity of TSOM may match or exceed the International Technology Roadmap for Semiconductors (ITRS) measurement requirements for the next several years. Both simulations and preliminary experimental results are presented. The simplicity, lowcost, high throughput, and nanometer scale 3-D shape sensitivity of TSOM make it an attractive inspection and process monitoring solution for nanomanufacturing. PMID:27464112

  4. Measuring visual discomfort associated with 3D displays

    NASA Astrophysics Data System (ADS)

    Lambooij, M.; Fortuin, M.; Ijsselsteijn, W. A.; Heynderickx, I.

    2009-02-01

    Some people report visual discomfort when watching 3D displays. For both the objective measurement of visual fatigue and the subjective measurement of visual discomfort, we would like to arrive at general indicators that are easy to apply in perception experiments. Previous research yielded contradictory results concerning such indicators. We hypothesize two potential causes for this: 1) not all clinical tests are equally appropriate to evaluate the effect of stereoscopic viewing on visual fatigue, and 2) there is a natural variation in susceptibility to visual fatigue amongst people with normal vision. To verify these hypotheses, we designed an experiment, consisting of two parts. Firstly, an optometric screening was used to differentiate participants in susceptibility to visual fatigue. Secondly, in a 2×2 within-subjects design (2D vs 3D and two-view vs nine-view display), a questionnaire and eight optometric tests (i.e. binocular acuity, fixation disparity with and without fusion lock, heterophoria, convergent and divergent fusion, vergence facility and accommodation response) were administered before and immediately after a reading task. Results revealed that participants found to be more susceptible to visual fatigue during screening showed a clinically meaningful increase in fusion amplitude after having viewed 3D stimuli. Two questionnaire items (i.e., pain and irritation) were significantly affected by the participants' susceptibility, while two other items (i.e., double vision and sharpness) were scored differently between 2D and 3D for all participants. Our results suggest that a combination of fusion range measurements and self-report is appropriate for evaluating visual fatigue related to 3D displays.

  5. Electro-bending characterization of adaptive 3D fiber reinforced plastics based on shape memory alloys

    NASA Astrophysics Data System (ADS)

    Ashir, Moniruddoza; Hahn, Lars; Kluge, Axel; Nocke, Andreas; Cherif, Chokri

    2016-03-01

    The industrial importance of fiber reinforced plastics (FRPs) is growing steadily in recent years, which are mostly used in different niche products, has been growing steadily in recent years. The integration of sensors and actuators in FRP is potentially valuable for creating innovative applications and therefore the market acceptance of adaptive FRP is increasing. In particular, in the field of highly stressed FRP, structural integrated systems for continuous component parts monitoring play an important role. This presented work focuses on the electro-mechanical characterization of adaptive three-dimensional (3D)FRP with integrated textile-based actuators. Here, the friction spun hybrid yarn, consisting of shape memory alloy (SMA) in wire form as core, serves as an actuator. Because of the shape memory effect, the SMA-hybrid yarn returns to its original shape upon heating that also causes the deformation of adaptive 3D FRP. In order to investigate the influences of the deformation behavior of the adaptive 3D FRP, investigations in this research are varied according to the structural parameters such as radius of curvature of the adaptive 3D FRP, fabric types and number of layers of the fabric in the composite. Results show that reproducible deformations can be realized with adaptive 3D FRP and that structural parameters have a significant impact on the deformation capability.

  6. Does 3D Phenotyping Yield Substantial Insights in the Genetics of the Mouse Mandible Shape?

    PubMed Central

    Navarro, Nicolas; Maga, A. Murat

    2016-01-01

    We describe the application of high-resolution 3D microcomputed tomography, together with 3D landmarks and geometric morphometrics, to validate and further improve previous quantitative genetic studies that reported QTL responsible for variation in the mandible shape of laboratory mice using a new backcross between C57BL/6J and A/J inbred strains. Despite the increasing availability of 3D imaging techniques, artificial flattening of the mandible by 2D imaging techniques seems at first an acceptable compromise for large-scale phenotyping protocols, thanks to an abundance of low-cost digital imaging systems such as microscopes or digital cameras. We evaluated the gain of information from considering explicitly this additional third dimension, and also from capturing variation on the bone surface where no precise anatomical landmark can be marked. Multivariate QTL mapping conducted with different landmark configurations (2D vs. 3D; manual vs. semilandmarks) broadly agreed with the findings of previous studies. Significantly more QTL (23) were identified and more precisely mapped when the mandible shape was captured with a large set of semilandmarks coupled with manual landmarks. It appears that finer phenotypic characterization of the mandibular shape with 3D landmarks, along with higher density genotyping, yields better insights into the genetic architecture of mandibular development. Most of the main variation is, nonetheless, preferentially embedded in the natural 2D plane of the hemi-mandible, reinforcing the results of earlier influential investigations. PMID:26921296

  7. Shape optimization of 3D continuum structures via force approximation techniques

    NASA Technical Reports Server (NTRS)

    Vanderplaats, Garret N.; Kodiyalam, Srinivas

    1988-01-01

    The existing need to develop methods whereby the shape design efficiency can be improved through the use of high quality approximation methods is addressed. An efficient approximation method for stress constraints in 3D shape design problems is proposed based on expanding the nodal forces in Taylor series with respect to shape variations. The significance of this new method is shown through elementary beam theory calculations and via numerical computations using 3D solid finite elements. Numerical examples including the classical cantilever beam structure and realistic automotive parts like the engine connecting rod are designed for optimum shape using the proposed method. The numerical results obtained from these methods are compared with other published results, to assess the efficiency and the convergence rate of the proposed method.

  8. Classification and quantification of pore shapes in sandstone reservoir rocks with 3-D X-ray micro-computed tomography

    NASA Astrophysics Data System (ADS)

    Schmitt, Mayka; Halisch, Matthias; Müller, Cornelia; Peres Fernandes, Celso

    2016-02-01

    Recent years have seen a growing interest in the characterization of the pore morphologies of reservoir rocks and how the spatial organization of pore traits affects the macro behavior of rock-fluid systems. With the availability of 3-D high-resolution imaging, such as x-ray micro-computed tomography (µ-CT), the detailed quantification of particle shapes has been facilitated by progress in computer science. Here, we show how the shapes of irregular rock particles (pores) can be classified and quantified based on binary 3-D images. The methodology requires the measurement of basic 3-D particle descriptors (length, width, and thickness) and a shape classification that involves the similarity of artificial objects, which is based on main pore network detachments and 3-D sample sizes. Two main pore components were identified from the analyzed volumes: pore networks and residual pore ganglia. A watershed algorithm was applied to preserve the pore morphology after separating the main pore networks, which is essential for the pore shape characterization. The results were validated for three sandstones (S1, S2, and S3) from distinct reservoirs, and most of the pore shapes were found to be plate- and cube-like, ranging from 39.49 to 50.94 % and from 58.80 to 45.18 % when the Feret caliper descriptor was investigated in a 10003 voxel volume. Furthermore, this study generalizes a practical way to correlate specific particle shapes, such as rods, blades, cuboids, plates, and cubes to characterize asymmetric particles of any material type with 3-D image analysis.

  9. 3D Morphometric and Posture Study of Felid Scapulae Using Statistical Shape Modelling

    PubMed Central

    Zhang, Kai Yu; Wiktorowicz-Conroy, Alexis; Hutchinson, John R.; Doube, Michael; Klosowski, Michal; Shefelbine, Sandra J.; Bull, Anthony M. J.

    2012-01-01

    We present a three dimensional (3D) morphometric modelling study of the scapulae of Felidae, with a focus on the correlations between forelimb postures and extracted scapular shape variations. Our shape modelling results indicate that the scapular infraspinous fossa becomes larger and relatively broader along the craniocaudal axis in larger felids. We infer that this enlargement of the scapular fossa may be a size-related specialization for postural support of the shoulder joint. PMID:22509335

  10. Shape-based 3D vascular tree extraction for perforator flaps

    NASA Astrophysics Data System (ADS)

    Wen, Quan; Gao, Jean

    2005-04-01

    Perforator flaps have been increasingly used in the past few years for trauma and reconstructive surgical cases. With the thinned perforated flaps, greater survivability and decrease in donor site morbidity have been reported. Knowledge of the 3D vascular tree will provide insight information about the dissection region, vascular territory, and fascia levels. This paper presents a scheme of shape-based 3D vascular tree reconstruction of perforator flaps for plastic surgery planning, which overcomes the deficiencies of current existing shape-based interpolation methods by applying rotation and 3D repairing. The scheme has the ability to restore the broken parts of the perforator vascular tree by using a probability-based adaptive connection point search (PACPS) algorithm with minimum human intervention. The experimental results evaluated by both synthetic and 39 harvested cadaver perforator flaps show the promise and potential of proposed scheme for plastic surgery planning.

  11. Pavement cracking measurements using 3D laser-scan images

    NASA Astrophysics Data System (ADS)

    Ouyang, W.; Xu, B.

    2013-10-01

    Pavement condition surveying is vital for pavement maintenance programs that ensure ride quality and traffic safety. This paper first introduces an automated pavement inspection system which uses a three-dimensional (3D) camera and a structured laser light to acquire dense transverse profiles of a pavement lane surface when it carries a moving vehicle. After the calibration, the 3D system can yield a depth resolution of 0.5 mm and a transverse resolution of 1.56 mm pixel-1 at 1.4 m camera height from the ground. The scanning rate of the camera can be set to its maximum at 5000 lines s-1, allowing the density of scanned profiles to vary with the vehicle's speed. The paper then illustrates the algorithms that utilize 3D information to detect pavement distress, such as transverse, longitudinal and alligator cracking, and presents the field tests on the system's repeatability when scanning a sample pavement in multiple runs at the same vehicle speed, at different vehicle speeds and under different weather conditions. The results show that this dedicated 3D system can capture accurate pavement images that detail surface distress, and obtain consistent crack measurements in repeated tests and under different driving and lighting conditions.

  12. Mechanical properties and shape memory effect of 3D-printed PLA-based porous scaffolds.

    PubMed

    Senatov, F S; Niaza, K V; Zadorozhnyy, M Yu; Maksimkin, A V; Kaloshkin, S D; Estrin, Y Z

    2016-04-01

    In the present work polylactide (PLA)/15wt% hydroxyapatite (HA) porous scaffolds with pre-modeled structure were obtained by 3D-printing by fused filament fabrication. Composite filament was obtained by extrusion. Mechanical properties, structural characteristics and shape memory effect (SME) were studied. Direct heating was used for activation of SME. The average pore size and porosity of the scaffolds were 700μm and 30vol%, respectively. Dispersed particles of HA acted as nucleation centers during the ordering of PLA molecular chains and formed an additional rigid fixed phase that reduced molecular mobility, which led to a shift of the onset of recovery stress growth from 53 to 57°C. A more rapid development of stresses was observed for PLA/HA composites with the maximum recovery stress of 3.0MPa at 70°C. Ceramic particles inhibited the growth of cracks during compression-heating-compression cycles when porous PLA/HA 3D-scaffolds recovered their initial shape. Shape recovery at the last cycle was about 96%. SME during heating may have resulted in "self-healing" of scaffold by narrowing the cracks. PLA/HA 3D-scaffolds were found to withstand up to three compression-heating-compression cycles without delamination. It was shown that PLA/15%HA porous scaffolds obtained by 3D-printing with shape recovery of 98% may be used as self-fitting implant for small bone defect replacement owing to SME. PMID:26710259

  13. Measurement of the mobility edge for 3D Anderson localization

    NASA Astrophysics Data System (ADS)

    Semeghini, Giulia; Landini, Manuele; Castilho, Patricia; Roy, Sanjukta; Spagnolli, Giacomo; Trenkwalder, Andreas; Fattori, Marco; Inguscio, Massimo; Modugno, Giovanni

    2016-05-01

    An outstanding problem of Anderson localization (AL) in 3D systems is the determination of the mobility edge, i.e. the energy threshold that separates localized and extended states. In our experiment we use a Bose-Einstein condensate of 39 K atoms and study its transport properties in a disordered optical potential. By tuning the inter-particle interactions to zero via magnetic Feshbach resonances, we study the single-particle phenomenon of AL. A novel technique to measure and control the atomic energy distribution allows us to measure for the first time the position of the localization threshold as a function of the disorder strength. We also study how the addition of finite repulsive or attractive interactions breaks the localized regime and triggers subdiffusive expansion of the atoms. In the future, similar experiments might also probe the existence of many-body localization in 3D.

  14. A 3-D measurement of biomagnetic field and its application

    NASA Astrophysics Data System (ADS)

    Uchikawa, Yoshinori; Kim, Bong-Soo; Kobayashi, Koichiro

    2006-09-01

    This review paper focuses in the usefulness of three-dimensional (3-D) biomagnetic field measurement for discriminating multiple sources closely located and overlapped in time. We have developed a 3-D second-order gradiometer connected to 39-channel SQUIDs for vector measurement of magnetoencephalogram (MEG), which can simultaneously detect magnetic field components perpendicular and tangential to the scalp. To assess discrimination and separation of multiple sources overlapping in time, we showed both simulation study and 3-D vector measurement of MEG as following; (a) mixed auditory evoked field (AEF) and somatosensory evoked field (SEF), (b) separating second somatosensory (SII) activity from primary somatosensory (SI) activity in SEF. The magnetic field distribution perpendicular to the scalp was not helpful for estimating the location and number of sources, owing to the lack of a dipole pattern, but the magnetic field distribution tangential to the scalp can provide information about new constraint conditions by visual inspection and singular value decomposition (SVD) method. We estimated multiple sources of mixed AEF and SEF from the MEG data of the magnetic field tangential to the scalp, and also estimated multiple sources of SI and SII activity. These results were confirmed by comparison with superimposed source locations in MRI of subject's head.

  15. A method of multi-view intraoral 3D measurement

    NASA Astrophysics Data System (ADS)

    Zhao, Huijie; Wang, Zhen; Jiang, Hongzhi; Xu, Yang; Lv, Peijun; Sun, Yunchun

    2015-02-01

    In dental restoration, its important to achieve a high-accuracy digital impression. Most of the existing intraoral measurement systems can only measure the tooth from a single view. Therfore - if we are wilng to acquire the whole data of a tooth, the scans of the tooth from multi-direction ad the data stitching based on the features of the surface are needed, which increases the measurement duration and influence the measurement accuracy. In this paper, we introduce a fringe-projection based on multi-view intraoral measurement system. It can acquire 3D data of the occlusal surface, the buccal surface and the lingual surface of a tooth synchronously, by using a senor with three mirrors, which aim at the three surfaces respectively and thus expand the measuring area. The constant relationship of the three mirrors is calibrated before measurement and can help stitch the data clouds acquired through different mirrors accurately. Therefore the system can obtain the 3D data of a tooth without the need to measure it from different directions for many times. Experiments proved the availability and reliability of this miniaturized measurement system.

  16. A new 3D computational model for shaped charge jet breakup

    SciTech Connect

    Zernow, L.; Chapyak, E.J.; Mosso, S.J.

    1996-09-01

    This paper reviews prior 1D and 2D axisymmetric, analytical and computational studies, as well as empirical studies of the shaped charge jet particulation problem and discusses their associated insights and problems. It proposes a new 3D computational model of the particulation process, based upon a simplified version of the observed counter-rotating, double helical surface perturbations, found on softly recovered shaped charge jet particles, from both copper and tantalum jets. This 3D approach contrasts with the random, axisymmetric surface perturbations which have previously been used, to try to infer the observed length distribution of jet particles, on the basis of the most unstable wavelength concept, which leads to the expectation of a continuous distribution of particle lengths. The 3D model, by its very nature, leads to a non-random, periodic distribution of potential initial necking loci, on alternate sides of the stretching jet. This in turn infers a potentially periodic, overlapping, multi-modal distribution of associated jet particle lengths. Since it is unlikely that all potential initial necking sites will be activated simultaneously, the 3D model also suggests that longer jet particles containing partial, but unseparated necks, should be observed fairly often. The computational analysis is in its very early stages and the problems involved in inserting the two helical grooves and in defining the initial conditions and boundary conditions for the computation will be discussed. Available initial results from the 3D computation will be discussed and interpreted.

  17. Model-based 3D human shape estimation from silhouettes for virtual fitting

    NASA Astrophysics Data System (ADS)

    Saito, Shunta; Kouchi, Makiko; Mochimaru, Masaaki; Aoki, Yoshimitsu

    2014-03-01

    We propose a model-based 3D human shape reconstruction system from two silhouettes. Firstly, we synthesize a deformable body model from 3D human shape database consists of a hundred whole body mesh models. Each mesh model is homologous, so that it has the same topology and same number of vertices among all models. We perform principal component analysis (PCA) on the database and synthesize an Active Shape Model (ASM). ASM allows changing the body type of the model with a few parameters. The pose changing of our model can be achieved by reconstructing the skeleton structures from implanted joints of the model. By applying pose changing after body type deformation, our model can represents various body types and any pose. We apply the model to the problem of 3D human shape reconstruction from front and side silhouette. Our approach is simply comparing the contours between the model's and input silhouettes', we then use only torso part contour of the model to reconstruct whole shape. We optimize the model parameters by minimizing the difference between corresponding silhouettes by using a stochastic, derivative-free non-linear optimization method, CMA-ES.

  18. An improved 3D shape context registration method for non-rigid surface registration

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Zahra, David; Bourgeat, Pierrick; Berghofer, Paula; Acosta Tamayo, Oscar; Wimberley, Catriona; Gregoire, Marie-Claude; Salvado, Olivier

    2010-03-01

    3D shape context is a method to define matching points between similar shapes as a pre-processing step to non-rigid registration. The main limitation of the approach is point mismatching, which includes long geodesic distance mismatch and neighbors crossing mismatch. In this paper, we propose a topological structure verification method to correct the long geodesic distance mismatch and a correspondence field smoothing method to correct the neighbors crossing mismatch. A robust 3D shape context model is proposed and further combined with thin-plate spline model for non-rigid surface registration. The method was tested on phantoms and rat hind limb skeletons from micro CT images. The results from experiments on mouse hind limb skeletons indicate that the approach is robust.

  19. Real-time structured light intraoral 3D measurement pipeline

    NASA Astrophysics Data System (ADS)

    Gheorghe, Radu; Tchouprakov, Andrei; Sokolov, Roman

    2013-02-01

    Computer aided design and manufacturing (CAD/CAM) is increasingly becoming a standard feature and service provided to patients in dentist offices and denture manufacturing laboratories. Although the quality of the tools and data has slowly improved in the last years, due to various surface measurement challenges, practical, accurate, invivo, real-time 3D high quality data acquisition and processing still needs improving. Advances in GPU computational power have allowed for achieving near real-time 3D intraoral in-vivo scanning of patient's teeth. We explore in this paper, from a real-time perspective, a hardware-software-GPU solution that addresses all the requirements mentioned before. Moreover we exemplify and quantify the hard and soft deadlines required by such a system and illustrate how they are supported in our implementation.

  20. A 3-D active shape model driven by fuzzy inference: application to cardiac CT and MR.

    PubMed

    van Assen, Hans C; Danilouchkine, Mikhail G; Dirksen, Martijn S; Reiber, Johan H C; Lelieveldt, Boudewijn P F

    2008-09-01

    Manual quantitative analysis of cardiac left ventricular function using Multislice CT and MR is arduous because of the large data volume. In this paper, we present a 3-D active shape model (ASM) for semiautomatic segmentation of cardiac CT and MR volumes, without the requirement of retraining the underlying statistical shape model. A fuzzy c-means based fuzzy inference system was incorporated into the model. Thus, relative gray-level differences instead of absolute gray values were used for classification of 3-D regions of interest (ROIs), removing the necessity of training different models for different modalities/acquisition protocols. The 3-D ASM was evaluated using 25 CT and 15 MR datasets. Automatically generated contours were compared to expert contours in 100 locations. For CT, 82.4% of epicardial contours and 74.1% of endocardial contours had a maximum error of 5 mm along 95% of the contour arc length. For MR, those numbers were 93.2% (epicardium) and 91.4% (endocardium). Volume regression analysis revealed good linear correlations between manual and semiautomatic volumes, r(2) >/= 0.98. This study shows that the fuzzy inference 3-D ASM is a robust promising instrument for semiautomatic cardiac left ventricle segmentation. Without retraining its statistical shape component, it is applicable to routinely acquired CT and MR studies. PMID:18779074

  1. Flexible geometrical calibration for fringe-reflection 3D measurement.

    PubMed

    Xiao, Yong-Liang; Su, Xianyu; Chen, Wenjing

    2012-02-15

    System geometrical calibration is a challenging task in fringe-reflection 3D measurement because the fringe displayed on the LCD screen does not lie within the camera's field of view. Commonly, a flat mirror with markers can accomplish system geometrical calibration. However, the position of the markers must be precisely located by photogrammetry in advance. In this Letter, we introduce a calibration method by use of a markerless flat mirror. Experiments in phase measuring deflectometry demonstrate that the proposed method is simple and flexible. PMID:22344126

  2. Heritability of Face Shape in Twins: A Preliminary Study using 3D Stereophotogrammetry and Geometric Morphometrics

    PubMed Central

    Weinberg, Seth M.; Parsons, Trish E.; Marazita, Mary L.; Maher, Brion S.

    2014-01-01

    Introduction Previous research suggests that aspects of facial surface morphology are heritable. Traditionally, heritability studies have used a limited set of linear distances to quantify facial morphology and often employ statistical methods poorly designed to deal with biological shape. In this preliminary report, we use a combination of 3D photogrammetry and landmark-based morphometrics to explore which aspects of face shape show the strongest evidence of heritability in a sample of twins. Methods 3D surface images were obtained from 21 twin pairs (10 monozygotic, 11 same-sex dizygotic). Thirteen 3D landmarks were collected from each facial surface and their coordinates subjected to geometric morphometric analysis. This involved superimposing the individual landmark configurations and then subjecting the resulting shape coordinates to a principal components analysis. The resulting PC scores were then used to calculate rough narrow-sense heritability estimates. Results Three principal components displayed evidence of moderate to high heritability and were associated with variation in the breadth of orbital and nasal structures, upper lip height and projection, and the vertical and forward projection of the root of the nose due to variation in the position of nasion. Conclusions Aspects of facial shape, primarily related to variation in length and breadth of central midfacial structures, were shown to demonstrate evidence of strong heritability. An improved understanding of which facial features are under strong genetic control is an important step in the identification of specific genes that underlie normal facial variation. PMID:24501696

  3. Interfacing electrogenic cells with 3D nanoelectrodes: position, shape, and size matter.

    PubMed

    Santoro, Francesca; Dasgupta, Sabyasachi; Schnitker, Jan; Auth, Thorsten; Neumann, Elmar; Panaitov, Gregory; Gompper, Gerhard; Offenhäusser, Andreas

    2014-07-22

    An in-depth understanding of the interface between cells and nanostructures is one of the key challenges for coupling electrically excitable cells and electronic devices. Recently, various 3D nanostructures have been introduced to stimulate and record electrical signals emanating from inside of the cell. Even though such approaches are highly sensitive and scalable, it remains an open question how cells couple to 3D structures, in particular how the engulfment-like processes of nanostructures work. Here, we present a profound study of the cell interface with two widely used nanostructure types, cylindrical pillars with and without a cap. While basic functionality was shown for these approaches before, a systematic investigation linking experimental data with membrane properties was not presented so far. The combination of electron microscopy investigations with a theoretical membrane deformation model allows us to predict the optimal shape and dimensions of 3D nanostructures for cell-chip coupling. PMID:24963873

  4. 3D time series analysis of cell shape using Laplacian approaches

    PubMed Central

    2013-01-01

    Background Fundamental cellular processes such as cell movement, division or food uptake critically depend on cells being able to change shape. Fast acquisition of three-dimensional image time series has now become possible, but we lack efficient tools for analysing shape deformations in order to understand the real three-dimensional nature of shape changes. Results We present a framework for 3D+time cell shape analysis. The main contribution is three-fold: First, we develop a fast, automatic random walker method for cell segmentation. Second, a novel topology fixing method is proposed to fix segmented binary volumes without spherical topology. Third, we show that algorithms used for each individual step of the analysis pipeline (cell segmentation, topology fixing, spherical parameterization, and shape representation) are closely related to the Laplacian operator. The framework is applied to the shape analysis of neutrophil cells. Conclusions The method we propose for cell segmentation is faster than the traditional random walker method or the level set method, and performs better on 3D time-series of neutrophil cells, which are comparatively noisy as stacks have to be acquired fast enough to account for cell motion. Our method for topology fixing outperforms the tools provided by SPHARM-MAT and SPHARM-PDM in terms of their successful fixing rates. The different tasks in the presented pipeline for 3D+time shape analysis of cells can be solved using Laplacian approaches, opening the possibility of eventually combining individual steps in order to speed up computations. PMID:24090312

  5. Simulated 3D ultrasound LV cardiac images for active shape model training

    NASA Astrophysics Data System (ADS)

    Butakoff, Constantine; Balocco, Simone; Ordas, Sebastian; Frangi, Alejandro F.

    2007-03-01

    In this paper a study of 3D ultrasound cardiac segmentation using Active Shape Models (ASM) is presented. The proposed approach is based on a combination of a point distribution model constructed from a multitude of high resolution MRI scans and the appearance model obtained from simulated 3D ultrasound images. Usually the appearance model is learnt from a set of landmarked images. The significant level of noise, the low resolution of 3D ultrasound images (3D US) and the frequent failure to capture the complete wall of the left ventricle (LV) makes automatic or manual landmarking difficult. One possible solution is to use artificially simulated 3D US images since the generated images will match exactly the shape in question. In this way, by varying simulation parameters and generating corresponding images, it is possible to obtain a training set where the image matches the shape exactly. In this work the simulation of ultrasound images is performed by a convolutional approach. The evaluation of segmentation accuracy is performed on both simulated and in vivo images. The results obtained on 567 simulated images had an average error of 1.9 mm (1.73 +/- 0.05 mm for epicardium and 2 +/- 0.07 mm for endocardium, with 95% confidence) with voxel size being 1.1 × 1.1 × 0.7 mm. The error on 20 in vivo data was 3.5 mm (3.44 +/- 0.4 mm for epicardium and 3.73 +/- 0.4 mm for endocardium). In most images the model was able to approximate the borders of myocardium even when the latter was indistinguishable from the surrounding tissues.

  6. Facile 3D Metal Electrode Fabrication for Energy Applications via Inkjet Printing and Shape Memory Polymer

    NASA Astrophysics Data System (ADS)

    Roberts, R. C.; Wu, J.; Hau, N. Y.; Chang, Y. H.; Feng, S. P.; Li, D. C.

    2014-11-01

    This paper reports on a simple 3D metal electrode fabrication technique via inkjet printing onto a thermally contracting shape memory polymer (SMP) substrate. Inkjet printing allows for the direct patterning of structures from metal nanoparticle bearing liquid inks. After deposition, these inks require thermal curing steps to render a stable conductive film. By printing onto a SMP substrate, the metal nanoparticle ink can be cured and substrate shrunk simultaneously to create 3D metal microstructures, forming a large surface area topology well suited for energy applications. Polystyrene SMP shrinkage was characterized in a laboratory oven from 150-240°C, resulting in a size reduction of 1.97-2.58. Silver nanoparticle ink was patterned into electrodes, shrunk, and the topology characterized using scanning electron microscopy. Zinc-Silver Oxide microbatteries were fabricated to demonstrate the 3D electrodes compared to planar references. Characterization was performed using 10M potassium hydroxide electrolyte solution doped with zinc oxide (57g/L). After a 300s oxidation at 3Vdc, the 3D electrode battery demonstrated a 125% increased capacity over the reference cell. Reference cells degraded with longer oxidations, but the 3D electrodes were fully oxidized for 4 hours, and exhibited a capacity of 5.5mA-hr/cm2 with stable metal performance.

  7. PRESAGE 3D dosimetry accurately measures Gamma Knife output factors

    NASA Astrophysics Data System (ADS)

    Klawikowski, Slade J.; Yang, James N.; Adamovics, John; Ibbott, Geoffrey S.

    2014-12-01

    Small-field output factor measurements are traditionally very difficult because of steep dose gradients, loss of lateral electronic equilibrium, and dose volume averaging in finitely sized detectors. Three-dimensional (3D) dosimetry is ideal for measuring small output factors and avoids many of these potential challenges of point and 2D detectors. PRESAGE 3D polymer dosimeters were used to measure the output factors for the 4 mm and 8 mm collimators of the Leksell Perfexion Gamma Knife radiosurgery treatment system. Discrepancies between the planned and measured distance between shot centers were also investigated. A Gamma Knife head frame was mounted onto an anthropomorphic head phantom. Special inserts were machined to hold 60 mm diameter, 70 mm tall cylindrical PRESAGE dosimeters. The phantom was irradiated with one 16 mm shot and either one 4 mm or one 8 mm shot, to a prescribed dose of either 3 Gy or 4 Gy to the 50% isodose line. The two shots were spaced between 30 mm and 60 mm apart and aligned along the central axis of the cylinder. The Presage dosimeters were measured using the DMOS-RPC optical CT scanning system. Five independent 4 mm output factor measurements fell within 2% of the manufacturer’s Monte Carlo simulation-derived nominal value, as did two independent 8 mm output factor measurements. The measured distances between shot centers varied by ±0.8 mm with respect to the planned shot displacements. On the basis of these results, we conclude that PRESAGE dosimetry is excellently suited to quantify the difficult-to-measure Gamma Knife output factors.

  8. Automated 3D measurement with the DCS200 digital camera

    NASA Astrophysics Data System (ADS)

    Van den Heuvel, Frank A.

    1994-03-01

    A digital photogrammetric system for automated 3D coordinate measurement in a production environment has been developed. For the image acquisition the Kodak DCS200 digital camera is used. This camera is based on a standard 35-mm camera. The results of the radiometric and geometric calibration of the DCS200 camera show the potential of this camera for photogrammetric applications. The software part of the system performs the detection, identification, and measurement of artificial targets present in digital images. These artificial targets are designed for automatic detection in images of a complex scene. For the identification of the targets a circular bar code is read by the image processing software. The least squares template matching method is implemented for the target image measurement. A precision better than 2% of a pixel was obtained for the target location. The 3D coordinate computation is performed by Geodelta's bundle adjustment package BINAER. It includes extensive statistical testing to assess the accuracy of the results. Tests with the DCS200 camera show a repeatability of 18 micrometer standard deviation on a test field 60 X 50 X 30 centimeter. The achieved precision is in the order of 2 (DOT) 10-5.

  9. Digital holography for recovering 3D shape of red blood cells

    NASA Astrophysics Data System (ADS)

    Memmolo, P.; Miccio, L.; Merola, F.; Gennari, O.; Netti, P.; Ferraro, Pietro

    2015-07-01

    Full morphometric data analysis and 3D rendering of Red Blood Cells (RBCs) is provided by means of Digital Holography (DH) in combination with Optical Tweezers (OT). The proposed method is compared with a geometrical model of RBC in order to evaluate its accuracy and tested for many kinds of RBCs, from healthy ones with double-concavity to that with abnormal shapes. Applications in diagnostics are foreseen.

  10. 3-D Human Action Recognition by Shape Analysis of Motion Trajectories on Riemannian Manifold.

    PubMed

    Devanne, Maxime; Wannous, Hazem; Berretti, Stefano; Pala, Pietro; Daoudi, Mohamed; Del Bimbo, Alberto

    2015-07-01

    Recognizing human actions in 3-D video sequences is an important open problem that is currently at the heart of many research domains including surveillance, natural interfaces and rehabilitation. However, the design and development of models for action recognition that are both accurate and efficient is a challenging task due to the variability of the human pose, clothing and appearance. In this paper, we propose a new framework to extract a compact representation of a human action captured through a depth sensor, and enable accurate action recognition. The proposed solution develops on fitting a human skeleton model to acquired data so as to represent the 3-D coordinates of the joints and their change over time as a trajectory in a suitable action space. Thanks to such a 3-D joint-based framework, the proposed solution is capable to capture both the shape and the dynamics of the human body, simultaneously. The action recognition problem is then formulated as the problem of computing the similarity between the shape of trajectories in a Riemannian manifold. Classification using k-nearest neighbors is finally performed on this manifold taking advantage of Riemannian geometry in the open curve shape space. Experiments are carried out on four representative benchmarks to demonstrate the potential of the proposed solution in terms of accuracy/latency for a low-latency action recognition. Comparative results with state-of-the-art methods are reported. PMID:25216492

  11. Learning the 3-D structure of objects from 2-D views depends on shape, not format

    PubMed Central

    Tian, Moqian; Yamins, Daniel; Grill-Spector, Kalanit

    2016-01-01

    Humans can learn to recognize new objects just from observing example views. However, it is unknown what structural information enables this learning. To address this question, we manipulated the amount of structural information given to subjects during unsupervised learning by varying the format of the trained views. We then tested how format affected participants' ability to discriminate similar objects across views that were rotated 90° apart. We found that, after training, participants' performance increased and generalized to new views in the same format. Surprisingly, the improvement was similar across line drawings, shape from shading, and shape from shading + stereo even though the latter two formats provide richer depth information compared to line drawings. In contrast, participants' improvement was significantly lower when training used silhouettes, suggesting that silhouettes do not have enough information to generate a robust 3-D structure. To test whether the learned object representations were format-specific or format-invariant, we examined if learning novel objects from example views transfers across formats. We found that learning objects from example line drawings transferred to shape from shading and vice versa. These results have important implications for theories of object recognition because they suggest that (a) learning the 3-D structure of objects does not require rich structural cues during training as long as shape information of internal and external features is provided and (b) learning generates shape-based object representations independent of the training format. PMID:27153196

  12. Shape representation for efficient landmark-based segmentation in 3-d.

    PubMed

    Ibragimov, Bulat; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2014-04-01

    In this paper, we propose a novel approach to landmark-based shape representation that is based on transportation theory, where landmarks are considered as sources and destinations, all possible landmark connections as roads, and established landmark connections as goods transported via these roads. Landmark connections, which are selectively established, are identified through their statistical properties describing the shape of the object of interest, and indicate the least costly roads for transporting goods from sources to destinations. From such a perspective, we introduce three novel shape representations that are combined with an existing landmark detection algorithm based on game theory. To reduce computational complexity, which results from the extension from 2-D to 3-D segmentation, landmark detection is augmented by a concept known in game theory as strategy dominance. The novel shape representations, game-theoretic landmark detection and strategy dominance are combined into a segmentation framework that was evaluated on 3-D computed tomography images of lumbar vertebrae and femoral heads. The best shape representation yielded symmetric surface distance of 0.75 mm and 1.11 mm, and Dice coefficient of 93.6% and 96.2% for lumbar vertebrae and femoral heads, respectively. By applying strategy dominance, the computational costs were further reduced for up to three times. PMID:24710155

  13. Learning the 3-D structure of objects from 2-D views depends on shape, not format.

    PubMed

    Tian, Moqian; Yamins, Daniel; Grill-Spector, Kalanit

    2016-05-01

    Humans can learn to recognize new objects just from observing example views. However, it is unknown what structural information enables this learning. To address this question, we manipulated the amount of structural information given to subjects during unsupervised learning by varying the format of the trained views. We then tested how format affected participants' ability to discriminate similar objects across views that were rotated 90° apart. We found that, after training, participants' performance increased and generalized to new views in the same format. Surprisingly, the improvement was similar across line drawings, shape from shading, and shape from shading + stereo even though the latter two formats provide richer depth information compared to line drawings. In contrast, participants' improvement was significantly lower when training used silhouettes, suggesting that silhouettes do not have enough information to generate a robust 3-D structure. To test whether the learned object representations were format-specific or format-invariant, we examined if learning novel objects from example views transfers across formats. We found that learning objects from example line drawings transferred to shape from shading and vice versa. These results have important implications for theories of object recognition because they suggest that (a) learning the 3-D structure of objects does not require rich structural cues during training as long as shape information of internal and external features is provided and (b) learning generates shape-based object representations independent of the training format. PMID:27153196

  14. Inter-point procrustes: identifying regional and large differences in 3D anatomical shapes.

    PubMed

    Lekadir, Karim; Frangi, Alejandro F; Yang, Guang-Zhong

    2012-01-01

    This paper presents a new approach for the robust alignment and interpretation of 3D anatomical structures with large and localized shape differences. In such situations, existing techniques based on the well-known Procrustes analysis can be significantly affected due to the introduced non-Gaussian distribution of the residuals. In the proposed technique, influential points that induce large dissimilarities are identified and displaced with the aim to obtain an intermediate template with an improved distribution of the residuals. The key element of the algorithm is the use of pose invariant shape variables to robustly guide both the influential point detection and displacement steps. The intermediate template is then used as the basis for the estimation of the final pose parameters between the source and destination shapes, enabling to effectively highlight the regional differences of interest. The validation using synthetic and real datasets of different morphologies demonstrates robustness up-to 50% regional differences and potential for shape classification. PMID:23286119

  15. The use of 3D shape models of Rosetta targets for morphological studies

    NASA Astrophysics Data System (ADS)

    Capanna, C.; Jorda, L.; Auger, A.-T.; Groussin, O.; Gaskell, R.; Hviid, S.; Lamy, P.

    2015-10-01

    New 3D reconstruction techniques have been developed during the last decade to retrieve the global and/or local topography of small solar system bodies from visible images. These techniques can be separated into two categories: the so-called "photoclinometric" and the so-called "photogrammetric" techniques. Two implementations of the photoclinometric technique are available: the SPC technique (StereoPhotoClinometry) which combines sparse stereo with a classical clinometry algorithm[1] and a more recent method called MSPCD (Multi- Resolution Stereo-PhotoClinometry by Deformation) which proceeds by iterative deformation of a triangular mesh in a multi-resolution scheme[2], using stereo points as a guide during the deformation[3]. Our study is based on the 3D shape models of the asteroid Lutetia and of the comet 67P/Churyumov- Gerasimenko retrieved by the SPC and MSPCD methods. More specifically, we describe how the models produced by these two techniques can contribute to detailed and quantitative studies of the morphological properties of small bodies through three test cases shortly described below.• Measurement of crater depth and depth-to-diameter distribution. We show that the reconstruction techniques can lead to systematic differences in the measurement of crater depth. This will be illustrated by a set of craters[4] identified in the Achaia region at the surface of the asteroid 21 Lutetia. • Calculation of the volume of large boulders at the surface of comet 67P/C-G. We show how the reconstruction technique affects significantly the volume determination of a large boulder named Cheops in the Imhotep region. • Measurement of gravitational slopes. We discuss the differences between the gravitational slope distributions in Seth obtained with the SPC and MSPCD models[5]. Since no ground control points are available on small bodies, we use the comparison of high-resolution images with the corresponding synthetic images generated with the models[6] to assess

  16. Unbiased contaminant removal for 3D galaxy power spectrum measurements

    NASA Astrophysics Data System (ADS)

    Kalus, B.; Percival, W. J.; Bacon, D. J.; Samushia, L.

    2016-08-01

    We assess and develop techniques to remove contaminants when calculating the 3D galaxy power spectrum. We separate the process into three separate stages: (i) removing the contaminant signal, (ii) estimating the uncontaminated cosmological power spectrum, (iii) debiasing the resulting estimates. For (i), we show that removing the best-fit contaminant (mode subtraction), and setting the contaminated components of the covariance to be infinite (mode deprojection) are mathematically equivalent. For (ii), performing a Quadratic Maximum Likelihood (QML) estimate after mode deprojection gives an optimal unbiased solution, although it requires the manipulation of large N_mode^2 matrices (Nmode being the total number of modes), which is unfeasible for recent 3D galaxy surveys. Measuring a binned average of the modes for (ii) as proposed by Feldman, Kaiser & Peacock (1994, FKP) is faster and simpler, but is sub-optimal and gives rise to a biased solution. We present a method to debias the resulting FKP measurements that does not require any large matrix calculations. We argue that the sub-optimality of the FKP estimator compared with the QML estimator, caused by contaminants is less severe than that commonly ignored due to the survey window.

  17. Quantitative prediction of 3D solution shape and flexibility of nucleic acid nanostructures.

    PubMed

    Kim, Do-Nyun; Kilchherr, Fabian; Dietz, Hendrik; Bathe, Mark

    2012-04-01

    DNA nanotechnology enables the programmed synthesis of intricate nanometer-scale structures for diverse applications in materials and biological science. Precise control over the 3D solution shape and mechanical flexibility of target designs is important to achieve desired functionality. Because experimental validation of designed nanostructures is time-consuming and cost-intensive, predictive physical models of nanostructure shape and flexibility have the capacity to enhance dramatically the design process. Here, we significantly extend and experimentally validate a computational modeling framework for DNA origami previously presented as CanDo [Castro,C.E., Kilchherr,F., Kim,D.-N., Shiao,E.L., Wauer,T., Wortmann,P., Bathe,M., Dietz,H. (2011) A primer to scaffolded DNA origami. Nat. Meth., 8, 221-229.]. 3D solution shape and flexibility are predicted from basepair connectivity maps now accounting for nicks in the DNA double helix, entropic elasticity of single-stranded DNA, and distant crossovers required to model wireframe structures, in addition to previous modeling (Castro,C.E., et al.) that accounted only for the canonical twist, bend and stretch stiffness of double-helical DNA domains. Systematic experimental validation of nanostructure flexibility mediated by internal crossover density probed using a 32-helix DNA bundle demonstrates for the first time that our model not only predicts the 3D solution shape of complex DNA nanostructures but also their mechanical flexibility. Thus, our model represents an important advance in the quantitative understanding of DNA-based nanostructure shape and flexibility, and we anticipate that this model will increase significantly the number and variety of synthetic nanostructures designed using nucleic acids. PMID:22156372

  18. Characterization measurements of ASC FLASH 3D ladar

    NASA Astrophysics Data System (ADS)

    Larsson, Håkan; Gustafsson, Frank; Johnson, Bruce; Richmond, Richard; Armstrong, Ernest

    2009-09-01

    As a part of the project agreement between the Swedish Defence Research Agency (FOI) and the United States of American's Air Force Research Laboratory (AFRL), a joint field trial was performed in Sweden during two weeks in January 2009. The main purpose for this trial was to characterize AFRL's latest version of the ASC (Advanced Scientific Concepts [1]) FLASH 3D LADAR sensor. The measurements were performed essentially in FOI´s optical hall whose 100 m indoor range offers measurements under controlled conditions minimizing effects such as atmospheric turbulence. Data were also acquired outdoor in both forest and urban scenarios, using vehicles and humans as targets, with the purpose of acquiring data from more dynamic platforms to assist in further algorithm development. This paper shows examples of the acquired data and presents initial results.

  19. 3-D laser anemometer measurements in a labyrinth seal

    NASA Technical Reports Server (NTRS)

    Morrison, G. L.; Tatterson, G. B.; Johnson, M. C.

    1988-01-01

    The flow field inside a seven cavity labyrinth seal with a 0.00127 m clearance was measured using a 3-D laser Doppler anemometer system. Through the use of this system, the mean velocity vector and the entire Reynolds stress tensor distributions were measured for the first, third, fifth, and seventh cavities of the seal. There was one large recirculation region present in the cavity for the flow condition tested, Re = 28,000 and Ta = 7,000. The axial and radial mean velocities as well as all of the Reynolds stress term became cavity independent by the third cavity. The azimuthal mean velocity varied from cavity to cavity with its magnitude increasing as the flow progressed downstream.

  20. 3D numerical simulation of the evolutionary process of aeolian downsized crescent-shaped dunes

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaosi; Zhang, Yang; Wang, Yuan; Li, Min

    2016-06-01

    A dune constitutive model was coupled with a large eddy simulation (LES) with the Smagorinsky subgrid-scale (SGS) model to accurately describe the evolutionary process of dunes from the macroscopic perspective of morphological dynamics. A 3D numerical simulation of the evolution of aeolian downsized crescent-shaped dunes was then performed. The evolution of the 3D structure of Gaussian-shaped dunes was simulated under the influence of gravity modulation, which was the same with the vertical oscillation of the sand bed to adjust the threshold of sand grain liftoff in wind tunnel experiments under the same wind speed. The influence of gravity modulation intensity on the characteristic scale parameter of the dune was discussed. Results indicated that the crescent shape of the dune was reproduced with the action of gravity during regulation of the saturation of wind-sand flow at specific times. The crescent shape was not dynamically maintained as time passed, and the dunes dwindled until they reached final decomposition because of wind erosion. The height of the dunes decreased over time, and the height-time curve converged as the intensity of modulation increased linearly. The results qualitatively agreed with those obtained from wind tunnel experiments.

  1. Study on portable optical 3D coordinate measuring system

    NASA Astrophysics Data System (ADS)

    Ren, Tongqun; Zhu, Jigui; Guo, Yinbiao

    2009-05-01

    A portable optical 3D coordinate measuring system based on digital Close Range Photogrammetry (CRP) technology and binocular stereo vision theory is researched. Three ultra-red LED with high stability is set on a hand-hold target to provide measuring feature and establish target coordinate system. Ray intersection based field directional calibrating is done for the intersectant binocular measurement system composed of two cameras by a reference ruler. The hand-hold target controlled by Bluetooth wireless communication is free moved to implement contact measurement. The position of ceramic contact ball is pre-calibrated accurately. The coordinates of target feature points are obtained by binocular stereo vision model from the stereo images pair taken by cameras. Combining radius compensation for contact ball and residual error correction, object point can be resolved by transfer of axes using target coordinate system as intermediary. This system is suitable for on-field large-scale measurement because of its excellent portability, high precision, wide measuring volume, great adaptability and satisfying automatization. It is tested that the measuring precision is near to +/-0.1mm/m.

  2. Interactive 3D medical data cutting using closed curve with arbitrary shape.

    PubMed

    Ning, Hai; Yang, Rongqian; Ma, Amin; Wu, Xiaoming

    2015-03-01

    Interactive 3D cutting is widely used as a flexible manual segmentation tool to extract medical data on regions of interest. A novel method for clipping 3D medical data is proposed to reveal the interior of volumetric data. The 3D cutting method retains or clips away selected voxels projected inside an arbitrary-shaped closed curve which is clipping geometry constructed by interactive tool to make cutting operation more flexible. Transformation between the world and screen coordinate frames is studied to project voxels of medical data onto the screen frame and avoid computing intersection of clipping geometry and volumetric data in 3D space. For facilitating the decision on whether the voxels should be retained, voxels through coordinate transformation are all projected onto a binary mask image on screen frame which the closed curve is also projected onto to conveniently obtain the voxels of intersection. The paper pays special attention to optimization algorithm of cutting process. The optimization algorithm that mixes octree with quad-tree decomposition is introduced to reduce computation complexity, save computation time, and match real time. The paper presents results obtained from raw and segmented medical volume datasets and the process time of cutting operation. PMID:25456145

  3. Estimating 3D Leaf and Stem Shape of Nursery Paprika Plants by a Novel Multi-Camera Photography System.

    PubMed

    Zhang, Yu; Teng, Poching; Shimizu, Yo; Hosoi, Fumiki; Omasa, Kenji

    2016-01-01

    For plant breeding and growth monitoring, accurate measurements of plant structure parameters are very crucial. We have, therefore, developed a high efficiency Multi-Camera Photography (MCP) system combining Multi-View Stereovision (MVS) with the Structure from Motion (SfM) algorithm. In this paper, we measured six variables of nursery paprika plants and investigated the accuracy of 3D models reconstructed from photos taken by four lens types at four different positions. The results demonstrated that error between the estimated and measured values was small, and the root-mean-square errors (RMSE) for leaf width/length and stem height/diameter were 1.65 mm (R² = 0.98) and 0.57 mm (R² = 0.99), respectively. The accuracies of the 3D model reconstruction of leaf and stem by a 28-mm lens at the first and third camera positions were the highest, and the number of reconstructed fine-scale 3D model shape surfaces of leaf and stem is the most. The results confirmed the practicability of our new method for the reconstruction of fine-scale plant model and accurate estimation of the plant parameters. They also displayed that our system is a good system for capturing high-resolution 3D images of nursery plants with high efficiency. PMID:27314348

  4. Estimating 3D Leaf and Stem Shape of Nursery Paprika Plants by a Novel Multi-Camera Photography System

    PubMed Central

    Zhang, Yu; Teng, Poching; Shimizu, Yo; Hosoi, Fumiki; Omasa, Kenji

    2016-01-01

    For plant breeding and growth monitoring, accurate measurements of plant structure parameters are very crucial. We have, therefore, developed a high efficiency Multi-Camera Photography (MCP) system combining Multi-View Stereovision (MVS) with the Structure from Motion (SfM) algorithm. In this paper, we measured six variables of nursery paprika plants and investigated the accuracy of 3D models reconstructed from photos taken by four lens types at four different positions. The results demonstrated that error between the estimated and measured values was small, and the root-mean-square errors (RMSE) for leaf width/length and stem height/diameter were 1.65 mm (R2 = 0.98) and 0.57 mm (R2 = 0.99), respectively. The accuracies of the 3D model reconstruction of leaf and stem by a 28-mm lens at the first and third camera positions were the highest, and the number of reconstructed fine-scale 3D model shape surfaces of leaf and stem is the most. The results confirmed the practicability of our new method for the reconstruction of fine-scale plant model and accurate estimation of the plant parameters. They also displayed that our system is a good system for capturing high-resolution 3D images of nursery plants with high efficiency. PMID:27314348

  5. A Skeleton-Based 3D Shape Reconstruction of Free-Form Objects with Stereo Vision

    NASA Astrophysics Data System (ADS)

    Saini, Deepika; Kumar, Sanjeev

    2015-12-01

    In this paper, an efficient approach is proposed for recovering the 3D shape of a free-form object from its arbitrary pair of stereo images. In particular, the reconstruction problem is treated as the reconstruction of the skeleton and the external boundary of the object. The reconstructed skeleton is termed as the line-like representation or curve-skeleton of the 3D object. The proposed solution for object reconstruction is based on this evolved curve-skeleton. It is used as a seed for recovering shape of the 3D object, and the extracted boundary is used for terminating the growing process of the object. NURBS-skeleton is used to extract the skeleton of both views. Affine invariant property of the convex hulls is used to establish the correspondence between the skeletons and boundaries in the stereo images. In the growing process, a distance field is defined for each skeleton point as the smallest distance from that point to the boundary of the object. A sphere centered at a skeleton point of radius equal to the minimum distance to the boundary is tangential to the boundary. Filling in the spheres centered at each skeleton point reconstructs the object. Several results are presented in order to check the applicability and validity of the proposed algorithm.

  6. Avalanche for shape and feature-based virtual screening with 3D alignment.

    PubMed

    Diller, David J; Connell, Nancy D; Welsh, William J

    2015-11-01

    This report introduces a new ligand-based virtual screening tool called Avalanche that incorporates both shape- and feature-based comparison with three-dimensional (3D) alignment between the query molecule and test compounds residing in a chemical database. Avalanche proceeds in two steps. The first step is an extremely rapid shape/feature based comparison which is used to narrow the focus from potentially millions or billions of candidate molecules and conformations to a more manageable number that are then passed to the second step. The second step is a detailed yet still rapid 3D alignment of the remaining candidate conformations to the query conformation. Using the 3D alignment, these remaining candidate conformations are scored, re-ranked and presented to the user as the top hits for further visualization and evaluation. To provide further insight into the method, the results from two prospective virtual screens are presented which show the ability of Avalanche to identify hits from chemical databases that would likely be missed by common substructure-based or fingerprint-based search methods. The Avalanche method is extended to enable patent landscaping, i.e., structural refinements to improve the patentability of hits for deployment in drug discovery campaigns. PMID:26458937

  7. Full-field strain measurements on turbomachinery components using 3D SLDV technology

    NASA Astrophysics Data System (ADS)

    Maguire, Martyn; Sever, Ibrahim

    2016-06-01

    This paper focuses on measurements of 3D Operating Deflection Shapes (ODSs), and subsequently, construction of full-field surface strain maps of a number of turbomachinery components. For this purpose a 3D Scanning Laser Doppler Vibrometer (SLDV) is used. The ODS measurements are performed for a large number of modes and results obtained are compared with the 1-D shapes that are most commonly measured. It is demonstrated that the 3D measurements are a significant improvement over the 1-D case in terms of independent amount of extra information they provide. This is confirmed through comparisons with FE results. Special tests are carried out to recover the full-field strain on scanned faces of the components used. Visual comparison of these measurements with FE counterparts reveal that strain maps can be successfully measured, not only for low frequency modes but also for highly complex high frequency ones. These maps are measured with different levels of input force to assess the linearity of strain results to varying response amplitudes. Lessons learnt and observations made are summarised in concluding remarks and the scope of future work to take this study into the production environment is discussed. This study constitutes a unique comprehensive investigation into full-field strain measurements using real application hardware and a large frequency range.

  8. 3D refractive index measurements of special optical fibers

    NASA Astrophysics Data System (ADS)

    Yan, Cheng; Huang, Su-Juan; Miao, Zhuang; Chang, Zheng; Zeng, Jun-Zhang; Wang, Ting-Yun

    2016-09-01

    A digital holographic microscopic chromatography-based approach with considerably improved accuracy, simplified configuration and performance stability is proposed to measure three dimensional refractive index of special optical fibers. Based on the approach, a measurement system is established incorporating a modified Mach-Zehnder interferometer and lab-developed supporting software for data processing. In the system, a phase projection distribution of an optical fiber is utilized to obtain an optimal digital hologram recorded by a CCD, and then an angular spectrum theory-based algorithm is adopted to extract the phase distribution information of an object wave. The rotation of the optic fiber enables the experimental measurements of multi-angle phase information. Based on the filtered back projection algorithm, a 3D refraction index of the optical fiber is thus obtained at high accuracy. To evaluate the proposed approach, both PANDA fibers and special elliptical optical fiber are considered in the system. The results measured in PANDA fibers agree well with those measured using S14 Refractive Index Profiler, which is, however, not suitable for measuring the property of a special elliptical fiber.

  9. Self-Assembly of Shaped Nanoparticles into Free-Standing 2D and 3D Superlattices.

    PubMed

    Li, Weikun; Wang, Ke; Zhang, Peng; He, Jie; Xu, Shaoyi; Liao, Yonggui; Zhu, Jintao; Xie, Xiaolin; Nie, Zhihong

    2016-01-27

    This article describes a novel supramolecular assembly-mediated strategy for the organization of Au nanoparticles (NPs) with different shapes (e.g., spheres, rods, and cubes) into large-area, free-standing 2D and 3D superlattices. This robust approach involves two major steps: (i) the organization of polymer-tethered NPs within the assemblies of supramolecular comblike block copolymers (CBCPs), and (ii) the disassembly of the assembled CBCP structures to produce free-standing NP superlattices. It is demonstrated that the crystal structures and lattice constants of the superlattices can be readily tailored by varying the molecular weight of tethered polymers, the volume fraction of NPs, and the matrix of CBCPs. This template-free approach may open a new avenue for the assembly of NPs into 2D and 3D structures with a wide range of potential applications. PMID:26649814

  10. Generation and use of measurement-based 3-D dose distributions for 3-D dose calculation verification.

    PubMed

    Stern, R L; Fraass, B A; Gerhardsson, A; McShan, D L; Lam, K L

    1992-01-01

    A 3-D radiation therapy treatment planning system calculates dose to an entire volume of points and therefore requires a 3-D distribution of measured dose values for quality assurance and dose calculation verification. To measure such a volumetric distribution with a scanning ion chamber is prohibitively time consuming. A method is presented for the generation of a 3-D grid of dose values based on beam's-eye-view (BEV) film dosimetry. For each field configuration of interest, a set of BEV films at different depths is obtained and digitized, and the optical densities are converted to dose. To reduce inaccuracies associated with film measurement of megavoltage photon depth doses, doses on the different planes are normalized using an ion-chamber measurement of the depth dose. A 3-D grid of dose values is created by interpolation between BEV planes along divergent beam rays. This matrix of measurement-based dose values can then be compared to calculations over the entire volume of interest. This method is demonstrated for three different field configurations. Accuracy of the film-measured dose values is determined by 1-D and 2-D comparisons with ion chamber measurements. Film and ion chamber measurements agree within 2% in the central field regions and within 2.0 mm in the penumbral regions. PMID:1620042

  11. Kinematic interpretation of the 3D shapes of metamorphic core complexes

    NASA Astrophysics Data System (ADS)

    Le Pourhiet, Laetitia; Huet, Benjamin; May, Dave A.; Labrousse, Loic; Jolivet, Laurent

    2012-09-01

    Metamorphic Core Complexes form dome shaped structures in which the ductile crust is exhumed beneath a detachment fault. The 3D dome geometry, inferred by mapping the schistosity in the exhumed crust, can be either elongated normal to the stretching direction or along it. In the first case, the domes are interpreted as having formed during extension. However, in the second case, they are interpreted either as strike-slip, transpressive or constrictive extensional structures, depending on the geodynamic context. Numerical models of metamorphic core complexes published to date are all two-dimensional and therefore, theoretically only apply to domes which are elongated normal to the stretching direction. Here, we explore by means of 3D thermomechanical modeling, the impact of 3D kinematic extensional boundary conditions on the shape of metamorphic core complexes. We examine the impact of a transtensional step over and of horsetail splay fault kinematics on the dynamics of exhumation, finite strain and P-T paths, and compare them to cylindrical 3D models. We show, for the first time, that domes formed in transtensional step over, or at the tip of propagating strike-slip faults, display a finite strain field which can be interpreted as characteristic of a transpressive domes, although no shortening was applied in the far-field. Applying our models to the Cyclades, we propose that the coeval formation of domes elongated normal and parallel to the stretching during the Miocene can be the result of horsetail splay fault kinematics, which could correspond to the formation of a tear in the Aegean slab.

  12. Laser 3-D measuring system and real-time visual feedback for teaching and correcting breathing

    NASA Astrophysics Data System (ADS)

    Povšič, Klemen; Fležar, Matjaž; Možina, Janez; Jezeršek, Matija

    2012-03-01

    We present a novel method for real-time 3-D body-shape measurement during breathing based on the laser multiple-line triangulation principle. The laser projector illuminates the measured surface with a pattern of 33 equally inclined light planes. Simultaneously, the camera records the distorted light pattern from a different viewpoint. The acquired images are transferred to a personal computer, where the 3-D surface reconstruction, shape analysis, and display are performed in real time. The measured surface displacements are displayed with a color palette, which enables visual feedback to the patient while breathing is being taught. The measuring range is approximately 400×600×500 mm in width, height, and depth, respectively, and the accuracy of the calibrated apparatus is +/-0.7 mm. The system was evaluated by means of its capability to distinguish between different breathing patterns. The accuracy of the measured volumes of chest-wall deformation during breathing was verified using standard methods of volume measurements. The results show that the presented 3-D measuring system with visual feedback has great potential as a diagnostic and training assistance tool when monitoring and evaluating the breathing pattern, because it offers a simple and effective method of graphical communication with the patient.

  13. 3D ESPI and 3D shearography measurements applied to NDT and FEM analysis validation for industrial quality control

    NASA Astrophysics Data System (ADS)

    Hack, Erwin K.; Riner, Marc

    2001-10-01

    Laser interferometric methods opened the way to measure displacements and deformations of an object in a while- field, non-contact and 3D manner. Therefore, they are used in non-destructive testing and validation of 3D finite element (FE) simulation results. This paper emphasizes the fact that the process of validating an FE result comprises in turn the validation and assessment of the optical measurement method and the experimental bou8ndary condition. Application examples for FE analysis validation and NDT from machine engineering, space technology, and biomedical engineering are presented.

  14. Magnetization reversal in 3D nano-structures of different shapes

    NASA Astrophysics Data System (ADS)

    Blachowicz, T.; Ehrmann, A.

    2016-04-01

    Magnetic nano-particles have been intensively studied during the last decade due to their potential utilization in various applications. An important topic is the dependence of magnetic properties on the exact samples shape. After demonstrating the influence of shape distortions in magnetic nano half-spheres on magnetization reversal processes and hysteresis shapes, a series of different 3D nano-objects from permalloy with shape modifications has been examined with respect to their magnetic properties. Modifications are performed by cutting parts of diverse samples between the extrema of a cuboid and a half-sphere. Simulations of these samples have been performed by Magpar, using external magnetic fields along two different axes, swept with two different speeds. Depending on the original particle shape and its modifications, several phenomena can be found: Cutting a hole in a cuboid can switch the hard axis from out-of-plane to the in-plane direction. In some nano-particles, strong oscillations occur which can be suppressed by appropriate shape modifications. In some of the nano-objects, the magnetization reversal mechanism is completely altered by a change in the field sweeping speed. The article gives an overview of the different possibilities to tailor magnetic properties of nano-systems.

  15. Quantitative wound healing measurement and monitoring system based on an innovative 3D imaging system

    NASA Astrophysics Data System (ADS)

    Yi, Steven; Yang, Arthur; Yin, Gongjie; Wen, James

    2011-03-01

    In this paper, we report a novel three-dimensional (3D) wound imaging system (hardware and software) under development at Technest Inc. System design is aimed to perform accurate 3D measurement and modeling of a wound and track its healing status over time. Accurate measurement and tracking of wound healing enables physicians to assess, document, improve, and individualize the treatment plan given to each wound patient. In current wound care practices, physicians often visually inspect or roughly measure the wound to evaluate the healing status. This is not an optimal practice since human vision lacks precision and consistency. In addition, quantifying slow or subtle changes through perception is very difficult. As a result, an instrument that quantifies both skin color and geometric shape variations would be particularly useful in helping clinicians to assess healing status and judge the effect of hyperemia, hematoma, local inflammation, secondary infection, and tissue necrosis. Once fully developed, our 3D imaging system will have several unique advantages over traditional methods for monitoring wound care: (a) Non-contact measurement; (b) Fast and easy to use; (c) up to 50 micron measurement accuracy; (d) 2D/3D Quantitative measurements;(e) A handheld device; and (f) Reasonable cost (< $1,000).

  16. A 3-D constitutive model for pressure-dependent phase transformation of porous shape memory alloys.

    PubMed

    Ashrafi, M J; Arghavani, J; Naghdabadi, R; Sohrabpour, S

    2015-02-01

    Porous shape memory alloys (SMAs) exhibit the interesting characteristics of porous metals together with shape memory effect and pseudo-elasticity of SMAs that make them appropriate for biomedical applications. In this paper, a 3-D phenomenological constitutive model for the pseudo-elastic behavior and shape memory effect of porous SMAs is developed within the framework of irreversible thermodynamics. Comparing to micromechanical and computational models, the proposed model is computationally cost effective and predicts the behavior of porous SMAs under proportional and non-proportional multiaxial loadings. Considering the pressure dependency of phase transformation in porous SMAs, proper internal variables, free energy and limit functions are introduced. With the aim of numerical implementation, time discretization and solution algorithm for the proposed model are also presented. Due to lack of enough experimental data on multiaxial loadings of porous SMAs, we employ a computational simulation method (CSM) together with available experimental data to validate the proposed constitutive model. The method is based on a 3-D finite element model of a representative volume element (RVE) with random pores pattern. Good agreement between the numerical predictions of the model and CSM results is observed for elastic and phase transformation behaviors in various thermomechanical loadings. PMID:25528691

  17. 3D nanopore shape control by current-stimulus dielectric breakdown

    NASA Astrophysics Data System (ADS)

    Ying, Cuifeng; Zhang, Yuechuan; Feng, Yanxiao; Zhou, Daming; Wang, Deqiang; Xiang, Yinxiao; Zhou, Wenyuan; Chen, Yongsheng; Du, Chunlei; Tian, Jianguo

    2016-08-01

    We propose a simple and cost-effect method, current-stimulus dielectric breakdown, to manipulate the 3D shapes of the nanochannels in 20-nm-thick SiNx membranes. Besides the precise control of nanopore size, the cone orientation can be determined by the pulse polarity. The cone angle of nanopores can be systematically tuned by simply changing the stimulus pulse waveform, allowing the gradual shape control from conical to obconical. After they are formed, the cone angle of these nanopores can be further tuned in a certain range by adjusting the widening pulse. Such size and 3D shape controllable abiotic nanopores can construct a constriction in the nanochannel and hence produce a sub-nm "sensing zone" to suit any desired bio-sensing or precise DNA sequencing. Using these conical nanopores, 20-nt ssDNA composed of homopolymers (poly(dA)20, poly(dC)20, and poly(dT)20) can be clearly differentiated by their ionic current signals.

  18. Illustrating Surface Shape in Volume Data via Principal Direction-Driven 3D Line Integral Convolution

    NASA Technical Reports Server (NTRS)

    Interrante, Victoria

    1997-01-01

    The three-dimensional shape and relative depth of a smoothly curving layered transparent surface may be communicated particularly effectively when the surface is artistically enhanced with sparsely distributed opaque detail. This paper describes how the set of principal directions and principal curvatures specified by local geometric operators can be understood to define a natural 'flow' over the surface of an object, and can be used to guide the placement of the lines of a stroke texture that seeks to represent 3D shape information in a perceptually intuitive way. The driving application for this work is the visualization of layered isovalue surfaces in volume data, where the particular identity of an individual surface is not generally known a priori and observers will typically wish to view a variety of different level surfaces from the same distribution, superimposed over underlying opaque structures. By advecting an evenly distributed set of tiny opaque particles, and the empty space between them, via 3D line integral convolution through the vector field defined by the principal directions and principal curvatures of the level surfaces passing through each gridpoint of a 3D volume, it is possible to generate a single scan-converted solid stroke texture that may intuitively represent the essential shape information of any level surface in the volume. To generate longer strokes over more highly curved areas, where the directional information is both most stable and most relevant, and to simultaneously downplay the visual impact of directional information in the flatter regions, one may dynamically redefine the length of the filter kernel according to the magnitude of the maximum principal curvature of the level surface at the point around which it is applied.

  19. Scale Space Graph Representation and Kernel Matching for Non Rigid and Textured 3D Shape Retrieval.

    PubMed

    Garro, Valeria; Giachetti, Andrea

    2016-06-01

    In this paper we introduce a novel framework for 3D object retrieval that relies on tree-based shape representations (TreeSha) derived from the analysis of the scale-space of the Auto Diffusion Function (ADF) and on specialized graph kernels designed for their comparison. By coupling maxima of the Auto Diffusion Function with the related basins of attraction, we can link the information at different scales encoding spatial relationships in a graph description that is isometry invariant and can easily incorporate texture and additional geometrical information as node and edge features. Using custom graph kernels it is then possible to estimate shape dissimilarities adapted to different specific tasks and on different categories of models, making the procedure a powerful and flexible tool for shape recognition and retrieval. Experimental results demonstrate that the method can provide retrieval scores similar or better than state-of-the-art on textured and non textured shape retrieval benchmarks and give interesting insights on effectiveness of different shape descriptors and graph kernels. PMID:26372206

  20. Automatic 3D kidney segmentation based on shape constrained GC-OAAM

    NASA Astrophysics Data System (ADS)

    Chen, Xinjian; Summers, Ronald M.; Yao, Jianhua

    2011-03-01

    The kidney can be classified into three main tissue types: renal cortex, renal medulla and renal pelvis (or collecting system). Dysfunction of different renal tissue types may cause different kidney diseases. Therefore, accurate and efficient segmentation of kidney into different tissue types plays a very important role in clinical research. In this paper, we propose an automatic 3D kidney segmentation method which segments the kidney into the three different tissue types: renal cortex, medulla and pelvis. The proposed method synergistically combines active appearance model (AAM), live wire (LW) and graph cut (GC) methods, GC-OAAM for short. Our method consists of two main steps. First, a pseudo 3D segmentation method is employed for kidney initialization in which the segmentation is performed slice-by-slice via a multi-object oriented active appearance model (OAAM) method. An improved iterative model refinement algorithm is proposed for the AAM optimization, which synergistically combines the AAM and LW method. Multi-object strategy is applied to help the object initialization. The 3D model constraints are applied to the initialization result. Second, the object shape information generated from the initialization step is integrated into the GC cost computation. A multi-label GC method is used to segment the kidney into cortex, medulla and pelvis. The proposed method was tested on 19 clinical arterial phase CT data sets. The preliminary results showed the feasibility and efficiency of the proposed method.

  1. A 3D measurement of the offset in paleoseismological studies

    NASA Astrophysics Data System (ADS)

    Ferrater, Marta; Echeverria, Anna; Masana, Eulàlia; Martínez-Díaz, José J.; Sharp, Warren D.

    2016-05-01

    The slip rate of a seismogenic fault is a crucial parameter for establishing the contribution of the fault to the seismic hazard. It is calculated from measurements of the offset of linear landforms, such channels, produced by the fault combined with their age. The three-dimensional measurement of offset in buried paleochannels is subject to uncertainties that need to be quantitatively assessed and propagated into the slip rate. Here, we present a set of adapted scripts to calculate the net, lateral and vertical tectonic offset components caused by faults, together with their associated uncertainties. This technique is applied here to a buried channel identified in the stratigraphic record during a paleoseismological study at the El Saltador site (Alhama de Murcia fault, Iberian Peninsula). After defining and measuring the coordinates of the key points of a buried channel in the walls of eight trenches excavated parallel to the fault, we (a) adjusted a 3D straight line to these points and then extrapolated the tendency of this line onto a simplified fault plane; (b) repeated these two steps for the segment of the channel in the other side of the fault; and (c) measured the distance between the two resulting intersection points with the fault plane. In doing so, we avoided the near fault modification of the channel trace and obtained a three-dimensional measurement of offset and its uncertainty. This methodology is a substantial modification of previous procedures that require excavating progressively towards the fault, leading to possible underestimation of offset due to diffuse deformation near the fault. Combining the offset with numerical dating of the buried channel via U-series on soil carbonate, we calculated a maximum estimate of the net slip rate and its vertical and lateral components for the Alhama de Murcia fault.

  2. 3D measurement of human upper body for gesture recognition

    NASA Astrophysics Data System (ADS)

    Wan, Khairunizam; Sawada, Hideyuki

    2007-10-01

    Measurement of human motion is widely required for various applications, and a significant part of this task is to identify motion in the process of human motion recognition. There are several application purposes of doing this research such as in surveillance, entertainment, medical treatment and traffic applications as user interfaces that require the recognition of different parts of human body to identify an action or a motion. The most challenging task in human motion recognition is to achieve the ability and reliability of a motion capture system for tracking and recognizing dynamic movements, because human body structure has many degrees of freedom. Many attempts for recognizing body actions have been reported so far, in which gestural motions have to be measured by some sensors first, and the obtained data are processed in a computer. This paper introduces the 3D motion analysis of human upper body using an optical motion capture system for the purpose of gesture recognition. In this study, the image processing technique to track optical markers attached at feature points of human body is introduced for constructing a human upper body model and estimating its three dimensional motion.

  3. Using 3-D shape models to guide segmentation of MR brain images.

    PubMed Central

    Hinshaw, K. P.; Brinkley, J. F.

    1997-01-01

    Accurate segmentation of medical images poses one of the major challenges in computer vision. Approaches that rely solely on intensity information frequently fail because similar intensity values appear in multiple structures. This paper presents a method for using shape knowledge to guide the segmentation process, applying it to the task of finding the surface of the brain. A 3-D model that includes local shape constraints is fitted to an MR volume dataset. The resulting low-resolution surface is used to mask out regions far from the cortical surface, enabling an isosurface extraction algorithm to isolate a more detailed surface boundary. The surfaces generated by this technique are comparable to those achieved by other methods, without requiring user adjustment of a large number of ad hoc parameters. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:9357670

  4. Analyzing the relevance of shape descriptors in automated recognition of facial gestures in 3D images

    NASA Astrophysics Data System (ADS)

    Rodriguez A., Julian S.; Prieto, Flavio

    2013-03-01

    The present document shows and explains the results from analyzing shape descriptors (DESIRE and Spherical Spin Image) for facial recognition of 3D images. DESIRE is a descriptor made of depth images, silhouettes and rays extended from a polygonal mesh; whereas the Spherical Spin Image (SSI) associated to a polygonal mesh point, is a 2D histogram built from neighboring points by using the position information that captures features of the local shape. The database used contains images of facial expressions which in average were recognized 88.16% using a neuronal network and 91.11% with a Bayesian classifier in the case of the first descriptor; in contrast, the second descriptor only recognizes in average 32% and 23,6% using the same mentioned classifiers respectively.

  5. Segmentation of the common carotid artery with active shape models from 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Yang, Xin; Jin, Jiaoying; He, Wanji; Yuchi, Ming; Ding, Mingyue

    2012-03-01

    Carotid atherosclerosis is a major cause of stroke, a leading cause of death and disability. In this paper, we develop and evaluate a new segmentation method for outlining both lumen and adventitia (inner and outer walls) of common carotid artery (CCA) from three-dimensional ultrasound (3D US) images for carotid atherosclerosis diagnosis and evaluation. The data set consists of sixty-eight, 17× 2× 2, 3D US volume data acquired from the left and right carotid arteries of seventeen patients (eight treated with 80mg atorvastain and nine with placebo), who had carotid stenosis of 60% or more, at baseline and after three months of treatment. We investigate the use of Active Shape Models (ASMs) to segment CCA inner and outer walls after statin therapy. The proposed method was evaluated with respect to expert manually outlined boundaries as a surrogate for ground truth. For the lumen and adventitia segmentations, respectively, the algorithm yielded Dice Similarity Coefficient (DSC) of 93.6%+/- 2.6%, 91.8%+/- 3.5%, mean absolute distances (MAD) of 0.28+/- 0.17mm and 0.34 +/- 0.19mm, maximum absolute distances (MAXD) of 0.87 +/- 0.37mm and 0.74 +/- 0.49mm. The proposed algorithm took 4.4 +/- 0.6min to segment a single 3D US images, compared to 11.7+/-1.2min for manual segmentation. Therefore, the method would promote the translation of carotid 3D US to clinical care for the fast, safety and economical monitoring of the atherosclerotic disease progression and regression during therapy.

  6. 3D pulmonary airway color image reconstruction via shape from shading and virtual bronchoscopy imaging techniques

    NASA Astrophysics Data System (ADS)

    Suter, Melissa; Reinhardt, Joseph M.; Hoffman, Eric A.; McLennan, Geoffrey

    2005-04-01

    The dependence on macro-optical imaging of the human body in the assessment of possible disease is rapidly increasing concurrent with, and as a direct result of, advancements made in medical imaging technologies. Assessing the pulmonary airways through bronchoscopy is performed extensively in clinical practice however remains highly subjective due to limited visualization techniques and the lack of quantitative analyses. The representation of 3D structures in 2D visualization modes, although providing an insight to the structural content of the scene, may in fact skew the perception of the structural form. We have developed two methods for visualizing the optically derived airway mucosal features whilst preserving the structural scene integrity. Shape from shading (SFS) techniques can be used to extract 3D structural information from 2D optical images. The SFS technique presented addresses many limitations previously encountered in conventional techniques resulting in high-resolution 3D color images. The second method presented to combine both color and structural information relies on combined CT and bronchoscopy imaging modalities. External imaging techniques such as CT provide a means of determining the gross structural anatomy of the pulmonary airways, however lack the important optically derived mucosal color. Virtual bronchoscopy is used to provide a direct link between the CT derived structural anatomy and the macro-optically derived mucosal color. Through utilization of a virtual and true bronchoscopy matching technique we are able to directly extract combined structurally sound 3D color segments of the pulmonary airways. Various pulmonary airway diseases are assessed and the resulting combined color and texture results are presented demonstrating the effectiveness of the presented techniques.

  7. 3D track initiation in clutter using 2D measurements

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Kirubarajan, Thiagalingam; Bar-Shalom, Yaakov

    2001-11-01

    In this paper we present an algorithm for initiating 3-D tracks using range and azimuth (bearing) measurements from a 2-D radar on a moving platform. The work is motivated by the need to track possibly low-flying targets, e.g., cruise missiles, using reports from an aircraft-based surveillance radar. Previous work on this problem considered simple linear motion in a flat earth coordinate frame. Our research extends this to a more realistic scenario where the earth"s curvature is also considered. The target is assumed to be moving along a great circle at a constant altitude. After the necessary coordinate transformations, the measurements are nonlinear functions of the target state and the observability of target altitude is severely limited. The observability, quantified by the Cramer-Rao Lower Bound (CRLB), is very sensitive to the sensor-to-target geometry. The paper presents a Maximum Likelihood (ML) estimator for estimating the target motion parameters in the Earth Centered Earth Fixed coordinate frame from 2-D range and angle measurements. In order to handle the possibility of false measurements and missed detections, which was not considered in, we use the Probabilistic Data Association (PDA) algorithm to weight the detections in a frame. The PDA-based modified global likelihood is optimized using a numerical search. The accuracies obtained by the resulting ML-PDA estimator are quantified using the CRLB for different sensor-target configurations. It is shown that the proposed estimator is efficient, that is, it meets the CRLB. Of particular interest is the achievable accuracy for estimating the target altitude, which is not observed directly by the 2-D radar, but can be only inferred from the range and bearing observations.

  8. 2D and 3D shape based segmentation using deformable models.

    PubMed

    El-Baz, Ayman; Yuksel, Seniha E; Shi, Hongjian; Farag, Aly A; El-Ghar, Mohamed A; Eldiasty, Tarek; Ghoneim, Mohamed A

    2005-01-01

    A novel shape based segmentation approach is proposed by modifying the external energy component of a deformable model. The proposed external energy component depends not only on the gray level of the images but also on the shape information which is obtained from the signed distance maps of objects in a given data set. The gray level distribution and the signed distance map of the points inside and outside the object of interest are accurately estimated by modelling the empirical density function with a linear combination of discrete Gaussians (LCDG) with positive and negative components. Experimental results on the segmentation of the kidneys from low-contrast DCE-MRI and on the segmentation of the ventricles from brain MRI's show how the approach is accurate in segmenting 2-D and 3-D data sets. The 2D results for the kidney segmentation have been validated by a radiologist and the 3D results of the ventricle segmentation have been validated with a geometrical phantom. PMID:16686036

  9. A cone-shaped 3D carbon nanotube probe for neural recording.

    PubMed

    Su, Huan-Chieh; Lin, Chia-Min; Yen, Shiang-Jie; Chen, Yung-Chan; Chen, Chang-Hsiao; Yeh, Shih-Rung; Fang, Weileun; Chen, Hsin; Yao, Da-Jeng; Chang, Yen-Chung; Yew, Tri-Rung

    2010-09-15

    A novel cone-shaped 3D carbon nanotube (CNT) probe is proposed as an electrode for applications in neural recording. The electrode consists of CNTs synthesized on the cone-shaped Si (cs-Si) tip by catalytic thermal chemical vapor deposition (CVD). This probe exhibits a larger CNT surface area with the same footprint area and higher spatial resolution of neural recording compared to planar-type CNT electrodes. An approach to improve CNT characteristics by O(2) plasma treatment to modify the CNT surface will be also presented. Electrochemical characterization of O(2) plasma-treated 3D CNT (OT-CNT) probes revealed low impedance per unit area (∼64.5 Ω mm(-2)) at 1 kHz and high specific capacitance per unit area (∼2.5 mF cm(-2)). Furthermore, the OT-CNT probes were employed to record the neural signals of a crayfish nerve cord. Our findings suggest that OT-CNT probes have potential advantages as high spatial resolution and superb electrochemical properties which are suitable for neural recording applications. PMID:20685101

  10. A 3D endoscopy reconstruction as a saliency map for analysis of polyp shapes

    NASA Astrophysics Data System (ADS)

    Ruano, Josue; Martínez, Fabio; Gómez, Martín.; Romero, Eduardo

    2015-01-01

    A first diagnosis of colorectal cancer is performed by examination of polyp shape and appearance during an endoscopy routine procedure. However, the video-endoscopy is highly noisy because exacerbated physiological conditions like increased motility or secretion may limit the visual analysis of lesions. In this work a 3D reconstruction of the digestive tract is proposed, facilitating the polyp shape evaluation by highlighting its surface geometry and allowing an analysis from different perspectives. The method starts by a spatio-temporal map, constructed to group the different regions of the tract by their similar dynamic patterns during the sequence. Then, such map was convolved with a second derivative of a Gaussian kernel that emulates the camera distortion and allows to highlight the polyp surface. The position initialization in each frame of the kernel was computed from expert manual delineation and propagated along the sequence based on. Results show reliable reconstructions, with a salient 3D polyp structure that can then be better observed.

  11. Methods for Measuring the Orientation and Rotation Rate of 3D-printed Particles in Turbulence.

    PubMed

    Cole, Brendan C; Marcus, Guy G; Parsa, Shima; Kramel, Stefan; Ni, Rui; Voth, Greg A

    2016-01-01

    Experimental methods are presented for measuring the rotational and translational motion of anisotropic particles in turbulent fluid flows. 3D printing technology is used to fabricate particles with slender arms connected at a common center. Shapes explored are crosses (two perpendicular rods), jacks (three perpendicular rods), triads (three rods in triangular planar symmetry), and tetrads (four arms in tetrahedral symmetry). Methods for producing on the order of 10,000 fluorescently dyed particles are described. Time-resolved measurements of their orientation and solid-body rotation rate are obtained from four synchronized videos of their motion in a turbulent flow between oscillating grids with Rλ = 91. In this relatively low-Reynolds number flow, the advected particles are small enough that they approximate ellipsoidal tracer particles. We present results of time-resolved 3D trajectories of position and orientation of the particles as well as measurements of their rotation rates. PMID:27404898

  12. Measuring a hidden coordinate: Rate-exchange kinetics from 3D correlation functions

    NASA Astrophysics Data System (ADS)

    Berg, Mark A.; Darvin, Jason R.

    2016-08-01

    Nonexponential kinetics imply the existence of at least one slow variable other than the observable, that is, the system has a "hidden" coordinate. We develop a simple, but general, model that allows multidimensional correlation functions to be calculated for these systems. Homogeneous and heterogeneous mechanisms are both included, and slow exchange of the rates is allowed. This model shows that 2D and 3D correlation functions of the observable measure the distribution and kinetics of the hidden coordinate controlling the rate exchange. Both the mean exchange time and the shape of the exchange relaxation are measurable. However, complications arise because higher correlation functions are sums of multiple "pathways," each of which measures different dynamics. Only one 3D pathway involves exchange dynamics. Care must be used to extract exchange dynamics without contamination from other processes.

  13. The modeling of portable 3D vision coordinate measuring system

    NASA Astrophysics Data System (ADS)

    Liu, Shugui; Huang, Fengshan; Peng, Kai

    2005-02-01

    The portable three-dimensional vision coordinate measuring system, which consists of a light pen, a CCD camera and a laptop computer, can be widely applied in most coordinate measuring fields especially on the industrial spots. On the light pen there are at least three point-shaped light sources (LEDs) acting as the measured control characteristic points and a touch trigger probe with a spherical stylus which is used to contact the point to be measured. The most important character of this system is that three light sources and the probe stylus are aligned in one line with known positions. In building and studying this measuring system, how to construct the system"s mathematical model is the most key problem called perspective of three-collinear-points problem, which is a particular case of perspective of three-points problem (P3P). On the basis of P3P and spatial analytical geometry theory, the system"s mathematical model is established in this paper. What"s more, it is verified that perspective of three-collinear-points problem has a unique solution. And the analytical equations of the measured point"s coordinates are derived by using the system"s mathematical model and the restrict condition that three light sources and the probe stylus are aligned in one line. Finally, the effectiveness of the mathematical model is confirmed by experiments.

  14. New 3-D coordination polymers based on semi-rigid V-shape tetracarboxylates

    SciTech Connect

    Huang, Jing-Jing; Xu, Wei; Wang, Yan-Ning; Yu, Jie-Hui; Zhang, Ping; Xu, Ji-Qing

    2015-03-15

    Under the hydrothermal conditions, the reactions of transition-metal salts, tetracarboxylic acids and N,N′-donor ligands yielded three new coordination polymers as [Cu{sub 4}(fph){sub 2}(bpe){sub 3}(H{sub 2}O){sub 2}]·2H{sub 2}O (fph=4,4′-(hexafluoroisopropylidene)diphthalate, bpe=1,2-bis(pyridyl)ethylene) 1, [Co{sub 2}(fph)(bpa){sub 2}(H{sub 2}O){sub 2}]·3H{sub 2}O (bpa=1,2-bis(pyridyl)ethylane) 2, and [Ni(H{sub 2}O)(H{sub 2}oph)(bpa)] (oph=4,4′-oxydiphthalate) 3. X-ray single-crystal diffraction analysis revealed that the title three compounds all possess the three-dimensional (3-D) network structures. For compound 1, the fph molecules first link the Cu{sup 2+} ions into a two-dimensional (2-D) wave-like layer with a (4,4) topology. The bpe molecules act as the second linkers, extending the 2-D layers into a 3-D network. For compound 2, the fph molecules still serve as the first connectors, linking the Co{sup 2+} ions into a one-dimensional (1-D) tube-like chain. Then the bpa molecules propagate the chains into a 3-D (4,4,4)-connected network. In the formation of the 3-D network of compound 3, the oph molecule does not play a role. The bpa molecules as well as the water molecules act as a mixed bridge. Only a kind of 4-connected metal node is observed in compound 3. The magnetic properties of compounds 1–3 were investigated and all exhibit the predominant antiferromegnetic magnetic behaviors. - Graphical abstract: Structures of three semi-rigid V-shape tetracarboxylate-based coordination polymers were reported, and their magnetic properties were investigated. - Highlights: • Structures of three tetracarboxylate-based coordination polymers were reported. • Role of organic bases in metal–tetracarboxylate compounds was discussed. • Characters of V-shape and semi-rigidity for tetracarboxylate play a key role in crystal growth. • Their magnetic properties were investigated.

  15. Experimental comparison of laser speckle projection and array projection for high-speed 3D measurements

    NASA Astrophysics Data System (ADS)

    Heist, Stefan; Lutzke, Peter; Dietrich, Patrick; Kühmstedt, Peter; Notni, Gunther

    2015-05-01

    In many application areas, stereo vision-based active triangulation systems are used to reconstruct the three-dimensional (3-D) surface shape of measurement objects. Typically, in order to solve the correspondence problem and increase the accuracy of the pixel assignment, a sequence of patterns is projected onto the object's surface and simultaneously recorded by two cameras. Most 3-D measurement systems are limited to static objects. In order to enhance their speed, it is necessary to use fast cameras as well as fast projection systems. Although high-speed camera systems are available, pattern projection at high frame rates is a difficult task and only a few techniques exist at the moment. In this contribution, we compare two different projection approaches, a laser-based speckle projection unit and an LED-based multi-aperture projection system, with regard to the achievable point cloud completeness and accuracy.

  16. On 3-D modeling and automatic regridding in shape design sensitivity analysis

    NASA Technical Reports Server (NTRS)

    Choi, Kyung K.; Yao, Tse-Min

    1987-01-01

    The material derivative idea of continuum mechanics and the adjoint variable method of design sensitivity analysis are used to obtain a computable expression for the effect of shape variations on measures of structural performance of three-dimensional elastic solids.

  17. 3D Measurement of Anatomical Cross-sections of Foot while Walking

    NASA Astrophysics Data System (ADS)

    Kimura, Makoto; Mochimaru, Masaaki; Kanade, Takeo

    Recently, techniques for measuring and modeling of human body are taking attention, because human models are useful for ergonomic design in manufacturing. We aim to measure accurate shape of human foot that will be useful for the design of shoes. For such purpose, shape measurement of foot in motion is obviously important, because foot shape in the shoe is deformed while walking or running. In this paper, we propose a method to measure anatomical cross-sections of foot while walking. No one had ever measured dynamic shape of anatomical cross-sections, though they are very basic and popular in the field of biomechanics. Our proposed method is based on multi-view stereo method. The target cross-sections are painted in individual colors (red, green, yellow and blue), and the proposed method utilizes the characteristic of target shape in the camera captured images. Several nonlinear conditions are introduced in the process to find the consistent correspondence in all images. Our desired accuracy is less than 1mm error, which is similar to the existing 3D scanners for static foot measurement. In our experiments, the proposed method achieved the desired accuracy.

  18. Method for 3D noncontact measurements of cut trees package area

    NASA Astrophysics Data System (ADS)

    Knyaz, Vladimir A.; Vizilter, Yuri V.

    2001-02-01

    Progress in imaging sensors and computers create the background for numerous 3D imaging application for wide variety of manufacturing activity. Many demands for automated precise measurements are in wood branch of industry. One of them is the accurate volume definition for cut trees carried on the truck. The key point for volume estimation is determination of the front area of the cut tree package. To eliminate slow and inaccurate manual measurements being now in practice the experimental system for automated non-contact wood measurements is developed. The system includes two non-metric CCD video cameras, PC as central processing unit, frame grabbers and original software for image processing and 3D measurements. The proposed method of measurement is based on capturing the stereo pair of front of trees package and performing the image orthotranformation into the front plane. This technique allows to process transformed image for circle shapes recognition and calculating their area. The metric characteristics of the system are provided by special camera calibration procedure. The paper presents the developed method of 3D measurements, describes the hardware used for image acquisition and the software realized the developed algorithms, gives the productivity and precision characteristics of the system.

  19. Tuning Cell Differentiation into a 3D Scaffold Presenting a Pore Shape Gradient for Osteochondral Regeneration.

    PubMed

    Di Luca, Andrea; Lorenzo-Moldero, Ivan; Mota, Carlos; Lepedda, Antonio; Auhl, Dietmar; Van Blitterswijk, Clemens; Moroni, Lorenzo

    2016-07-01

    Osteochondral regeneration remains nowadays a major problem since the outcome of current techniques is not satisfactory in terms of functional tissue formation and development. A possible solution is the combination of human mesenchymal stem cells (hMSCs) with additive manufacturing technologies to fabricate scaffolds with instructive properties. In this study, the differentiation of hMSCs within a scaffold presenting a gradient in pore shape is presented. The variation in pore shape is determined by varying the angle formed by the fibers of two consequent layers. The fiber deposition patterns are 0-90, which generate squared pores, 0-45, 0-30, and 0-15, that generate rhomboidal pores with an increasing major axis as the deposition angle decreases. Within the gradient construct, squared pores support a better chondrogenic differentiation whereas cells residing in the rhomboidal pores display a better osteogenic differentiation. When cultured under osteochondral conditions the trend in both osteogenic and chondrogenic markers is maintained. Engineering the pore shape, thus creating axial gradients in structural properties, seems to be an instructive strategy to fabricate functional 3D scaffolds that are able to influence hMSCs differentiation for osteochondral tissue regeneration. PMID:27109461

  20. Direct electrospinning of 3D auricle-shaped scaffolds for tissue engineering applications.

    PubMed

    Walser, Jochen; Stok, Kathryn S; Caversaccio, Marco D; Ferguson, Stephen J

    2016-01-01

    Thirty-two poly(ε)caprolactone (PCL) scaffolds have been produced by electrospinning directly into an auricle-shaped mould and seeded with articular chondrocytes harvested from bovine ankle joints. After seeding, the auricle shaped constructs were cultured in vitro and analysed at days 1, 7, 14 and 21 for regional differences in total DNA, glycosaminoglycan (GAG) and collagen (COL) content as well as the expression of aggrecan (AGG), collagen type I and type II (COL1/2) and matrix metalloproteinase 3 and 13 (MMP3/13). Stress-relaxation indentation testing was performed to investigate regional mechanical properties of the electrospun constructs. Electrospinning into a conductive mould yielded stable 3D constructs both initially and for the whole in vitro culture period, with an equilibrium modulus in the MPa range. Rapid cell proliferation and COL accumulation was observed until week 3. Quantitative real time PCR analysis showed an initial increase in AGG, no change in COL2, a persistent increase in COL1, and only a slight decrease initially for MMP3. Electrospinning of fibrous scaffolds directly into an auricle-shape represents a promising option for auricular tissue engineering, as it can reduce the steps needed to achieve an implantable structure. PMID:27171651

  1. GEM printer: 3D gel printer for free shaping of functional gel engineering materials

    NASA Astrophysics Data System (ADS)

    Furukawa, Hidemitsu; Muroi, Hisato; Yamamoto, Kouki; Serizawa, Ryo; Gong, Jin

    2013-04-01

    In the past decade, several high-strength gels have been developed. These gels are expected to use as a kind of new engineering materials in the fields of industry and medical as substitutes to polyester fibers, which are materials of artificial blood vessels. The gels have both low surface friction and well permeability due to a large amount of water absorbed in the gels, which are superiority of the gels compering to the polyester fibers. It is, however, difficult for gels to be forked structure or cavity structure by using cutting or mold. Consequently, it is necessary to develop the additive manufacturing device to synthesize and mode freely gels at the same time. Here we try to develop an optical 3D gel printer that enables gels to be shaped precisely and freely. For the free forming of high-strength gels, the 1st gels are ground to particles and mixed with 2nd pregel solution, and the mixed solution is gelled by the irradiation of UV laser beam through an optical fiber. The use of the optical fiber makes one-point UV irradiation possible. Since the optical fiber is controlled by 3D-CAD, the precise and free molding in XYZ directions is easily realized. We successfully synthesized tough gels using the gel printer.

  2. 3D shape descriptors for face segmentation and fiducial points detection: an anatomical-based analysis

    NASA Astrophysics Data System (ADS)

    Salazar, Augusto E.; Cerón, Alexander; Prieto, Flavio A.

    2011-03-01

    The behavior of nine 3D shape descriptors which were computed on the surface of 3D face models, is studied. The set of descriptors includes six curvature-based ones, SPIN images, Folded SPIN Images, and Finger prints. Instead of defining clusters of vertices based on the value of a given primitive surface feature, a face template composed by 28 anatomical regions, is used to segment the models and to extract the location of different landmarks and fiducial points. Vertices are grouped by: region, region boundaries, and subsampled versions of them. The aim of this study is to analyze the discriminant capacity of each descriptor to characterize regions and to identify key points on the facial surface. The experiment includes testing with data from neutral faces and faces showing expressions. Also, in order to see the usefulness of the bending-invariant canonical form (BICF) to handle variations due to facial expressions, the descriptors are computed directly from the surface and also from its BICF. In the results: the values, distributions, and relevance indexes of each set of vertices, were analyzed.

  3. Wrapping-free phase retrieval with applications to interferometry, 3D-shape profiling, and deflectometry.

    PubMed

    Perciante, César D; Strojnik, Marija; Paez, Gonzalo; Di Martino, J Matias; Ayubi, Gastón A; Flores, Jorge L; Ferrari, José A

    2015-04-01

    Phase unwrapping is probably the most challenging step in the phase retrieval process in phase-shifting and spatial-carrier interferometry. Likewise, phase unwrapping is required in 3D-shape profiling and deflectometry. In this paper, we present a novel phase retrieval method that completely sidesteps the phase unwrapping process, significantly eliminating the guessing in phase reconstruction and thus decreasing the time data processing. The proposed wrapping-free method is based on the direct integration of the spatial derivatives of the interference patterns under the single assumption that the phase is continuous. This assumption is valid in most physical applications. Validation experiments are presented confirming the robustness of the proposed method. PMID:25967217

  4. 3D prostate boundary segmentation from ultrasound images using 2D active shape models.

    PubMed

    Hodge, Adam C; Ladak, Hanif M

    2006-01-01

    Boundary outlining, or segmentation, of the prostate is an important task in diagnosis and treatment planning for prostate cancer. This paper describes an algorithm for semi-automatic, three-dimensional (3D) segmentation of the prostate boundary from ultrasound images based on two-dimensional (2D) active shape models (ASM) and rotation-based slicing. Evaluation of the algorithm used distance- and volume-based error metrics to compare algorithm generated boundary outlines to gold standard (manually generated) boundary outlines. The mean absolute distance between the algorithm and gold standard boundaries was 1.09+/-0.49 mm, the average percent absolute volume difference was 3.28+/-3.16%, and a 5x speed increase as compared manual planimetry was achieved. PMID:17946106

  5. Photoactive Self-Shaping Hydrogels as Noncontact 3D Macro/Microscopic Photoprinting Platforms.

    PubMed

    Liao, Yue; An, Ning; Wang, Ning; Zhang, Yinyu; Song, Junfei; Zhou, Jinxiong; Liu, Wenguang

    2015-12-01

    A photocleavable terpolymer hydrogel cross-linked with o-nitrobenzyl derivative cross-linker is shown to be capable of self-shaping without losing its physical integrity and robustness due to spontaneous asymmetric swelling of network caused by UV-light-induced gradient cleavage of chemical cross-linkages. The continuum model and finite element method are used to elucidate the curling mechanism underlying. Remarkably, based on the self-changing principle, the photosensitive hydrogels can be developed as photoprinting soft and wet platforms onto which specific 3D characters and images are faithfully duplicated in macro/microscale without contact by UV light irradiation under the cover of customized photomasks. Importantly, a quick response (QR) code is accurately printed on the photoactive hydrogel for the first time. Scanning QR code with a smartphone can quickly connect to a web page. This photoactive hydrogel is promising to be a new printing or recording material. PMID:26439808

  6. Solving tolerancing and 3D beam shaping problems by multifunctional wave optical design

    NASA Astrophysics Data System (ADS)

    Buehling, Sven; Wyrowski, Frank

    2000-10-01

    A strategy for designing optical systems that are optimized for multiple optical functions on the basis of wave optics is presented. Each optical function is composed of an input field, a set of fixed system parameters, and a merit function. A design algorithm is proposed which is applicable for optical systems consisting of an transmission operator followed by an arbitrary linear operator. The goal is to find the transmission operator which is optimal for all optical functions simultaneously. In later design steps, the found transmission operator can be transformed to real optical elements, for instance by using the thin element approximation. It is shown that the algorithm is efficiently applicable by investigating two sample applications for multifunctional wave optical design: the design of tolerant systems and 3D beam shaping.

  7. The Eta Carinae Homunculus in Full 3D with X-Shooter and Shape

    NASA Technical Reports Server (NTRS)

    Steffen, Wolfgang; Teodoro, Mairan; Madura, Thomas I.; Groh, Jose H.; Gull, Theodore R.; Mehner, Andrea; Corcoran, Michael F.; Damineli, Augusto; Hamaguchi, Kenji

    2014-01-01

    Massive stars like Eta Carinae are extremely rare in comparison to stars such as the Sun, and currently we know of only a handful of stars with masses of more than 100 solar mass in the Milky Way. Such massive stars were much more frequent in the early history of the Universe and had a huge impact on its evolution. Even among this elite club, Eta Car is outstanding, in particular because of its giant eruption around 1840 that produced the beautiful bipolar nebula now known as the Homunculus. In this study, we used detailed spatio-kinematic information obtained from X-shooter spectra to reconstruct the 3D structure of the Homunculus. The small-scale features suggest that the central massive binary played a significant role in shaping the Homunculus.

  8. The Eta Carinae Homunculus in Full 3D with X-shooter and Shape

    NASA Astrophysics Data System (ADS)

    Steffen, W.; Teodoro, M.; Madura, T. I.; Groh, J. H.; Gull, T. R.; Mehner, A.; Corcoran, M. F.; Damineli, A.; Hamaguchi, K.

    2014-12-01

    Massive stars like Eta Carinae are extremely rare in comparison to stars such as the Sun, and currently we know of only a handful of stars with masses of more than 100 Msun in the Milky Way. Such massive stars were much more frequent in the early history of the Universe and had a huge impact on its evolution. Even among this elite club, η Car is outstanding, in particular because of its giant eruption around 1840 that produced the beautiful bipolar nebula now known as the Homunculus. In this study, we used detailed spatio-kinematic information obtained from X-shooter spectra to reconstruct the 3D structure of the Homunculus. The small-scale features suggest that the central massive binary played a significant role in shaping the Homunculus.

  9. Shaping of light beams by 3D direct laser writing on facets of nonlinear crystals.

    PubMed

    Lightman, Shlomi; Gvishi, Raz; Hurvitz, Gilad; Arie, Ady

    2015-10-01

    We demonstrate experimentally spatial-mode conversions of light beams generated in a quadratic nonlinear process by micron-scale structures placed on the facets of nonlinear crystals. These structures were printed on the crystal facets using a three-dimensional (3D) direct laser writing system. The functional structures were designed to modify the phase of the beam at specific wavelengths, thereby enabling conversion of a fundamental Gaussian laser beam into different high-order Hermite-Gaussian modes, Laguerre-Gaussian modes, and zeroth-order Bessel beams of the second harmonic. This facet functionalization opens exciting new opportunities for robust and compact beam shaping in a nonlinear interaction without compromising the conversion efficiency. PMID:26421556

  10. Changes in quantitative 3D shape features of the optic nerve head associated with age

    NASA Astrophysics Data System (ADS)

    Christopher, Mark; Tang, Li; Fingert, John H.; Scheetz, Todd E.; Abramoff, Michael D.

    2013-02-01

    Optic nerve head (ONH) structure is an important biological feature of the eye used by clinicians to diagnose and monitor progression of diseases such as glaucoma. ONH structure is commonly examined using stereo fundus imaging or optical coherence tomography. Stereo fundus imaging provides stereo views of the ONH that retain 3D information useful for characterizing structure. In order to quantify 3D ONH structure, we applied a stereo correspondence algorithm to a set of stereo fundus images. Using these quantitative 3D ONH structure measurements, eigen structures were derived using principal component analysis from stereo images of 565 subjects from the Ocular Hypertension Treatment Study (OHTS). To evaluate the usefulness of the eigen structures, we explored associations with the demographic variables age, gender, and race. Using regression analysis, the eigen structures were found to have significant (p < 0.05) associations with both age and race after Bonferroni correction. In addition, classifiers were constructed to predict the demographic variables based solely on the eigen structures. These classifiers achieved an area under receiver operating characteristic curve of 0.62 in predicting a binary age variable, 0.52 in predicting gender, and 0.67 in predicting race. The use of objective, quantitative features or eigen structures can reveal hidden relationships between ONH structure and demographics. The use of these features could similarly allow specific aspects of ONH structure to be isolated and associated with the diagnosis of glaucoma, disease progression and outcomes, and genetic factors.

  11. Stylolite shape, roughness growth dynamics and related burial history: a 3D analysis.

    NASA Astrophysics Data System (ADS)

    Beaudoin, Nicolas; Koehn, Daniel

    2016-04-01

    Stylolites are dissolution features that develop under applied pressure and during chemical compaction. Stylolites are common in sedimentary basin, altering the chemistry and physical properties of rocks, as well as the small- to large-scale hydrological system. This contribution follows recent finding about the self-affine roughness growth properties leading to a fractal, stitch-like shape of stylolites. 3D surface scanning and X-ray computed microtomography imaging have been carried out onto numerous stylolites from the southern Permian Zechstein basin (Germany) and from the Umbria Marches fold-and-thrust belts (Italy). In these two environments stylolites have been sorted following a recent advanced classification of stylolite based on the shape and growth dynamics. This classification consists in four classes (rectangular layer type, seismogram pinning type suture/sharp peak type and simple wave-like type) and we aim to characterize the roughness properties for each of these classes. A fractal analysis has been conducted accordingly using Fourier transform and Correlation function signal analysis over roughness surfaces. These fractal analyses have been used to reconstruct the maximum burial depth recorded by each stylolite. The reconstruction of burial depths at the same place but regarding all stylolite classes returns and maximum depth evolution. This dataset is thus used 1- to understand the links between the roughness growth dynamics of stylolites and their final shape and 2- to establish a relationship linking the shape of roughness to the maximum burial depth recorded. We hope results and interpretation reported can push the community to consider stylolite as an efficient tool and reliable way to appraise burial history in sedimentary basins.

  12. 3D structural measurements of the proximal femur from 2D DXA images using a statistical atlas

    NASA Astrophysics Data System (ADS)

    Ahmad, Omar M.; Ramamurthi, Krishna; Wilson, Kevin E.; Engelke, Klaus; Bouxsein, Mary; Taylor, Russell H.

    2009-02-01

    A method to obtain 3D structural measurements of the proximal femur from 2D DXA images and a statistical atlas is presented. A statistical atlas of a proximal femur was created consisting of both 3D shape and volumetric density information and then deformably registered to 2D fan-beam DXA images. After the registration process, a series of 3D structural measurements were taken on QCT-estimates generated by transforming the registered statistical atlas into a voxel volume. These measurements were compared to the equivalent measurements taken on the actual QCT (ground truth) associated with the DXA images for each of 20 human cadaveric femora. The methodology and results are presented to address the potential clinical feasibility of obtaining 3D structural measurements from limited angle DXA scans and a statistical atlas of the proximal femur in-vivo.

  13. Comparison of organs' shapes with geometric and Zernike 3D moments.

    PubMed

    Broggio, D; Moignier, A; Ben Brahim, K; Gardumi, A; Grandgirard, N; Pierrat, N; Chea, M; Derreumaux, S; Desbrée, A; Boisserie, G; Aubert, B; Mazeron, J-J; Franck, D

    2013-09-01

    The morphological similarity of organs is studied with feature vectors based on geometric and Zernike 3D moments. It is particularly investigated if outliers and average models can be identified. For this purpose, the relative proximity to the mean feature vector is defined, principal coordinate and clustering analyses are also performed. To study the consistency and usefulness of this approach, 17 livers and 76 hearts voxel models from several sources are considered. In the liver case, models with similar morphological feature are identified. For the limited amount of studied cases, the liver of the ICRP male voxel model is identified as a better surrogate than the female one. For hearts, the clustering analysis shows that three heart shapes represent about 80% of the morphological variations. The relative proximity and clustering analysis rather consistently identify outliers and average models. For the two cases, identification of outliers and surrogate of average models is rather robust. However, deeper classification of morphological feature is subject to caution and can only be performed after cross analysis of at least two kinds of feature vectors. Finally, the Zernike moments contain all the information needed to re-construct the studied objects and thus appear as a promising tool to derive statistical organ shapes. PMID:23846154

  14. Localization of spots in FISH images of breast cancer using 3-D shape analysis.

    PubMed

    Les, T; Markiewicz, T; Osowski, S; Jesiotr, M; Kozlowski, W

    2016-06-01

    The fluorescence in situ (FISH) belongs to the most often used molecular cytogenetic techniques, applied in many areas of diagnosis and research. The analysis of FISH images relies on localization and counting the red and green spots in order to determine HER2 status of the breast cancer samples. The algorithm of spot localization presented in the paper is based on 3-D shape analysis of the image objects. The subsequent regions of the image are matched to the reference pattern and the results of this matching influence localization of spots. The paper compares different shapes of the reference pattern and their efficiency in spot localization. The numerical experiments have been performed on the basis of 12 cases (patients), each represented by three images. Few thousands of cells have been analysed. The quantitative analyses comparing different versions of algorithm are presented and compared to the expert results. The best version of the procedure provides the absolute relative difference to the expert results smaller than 3%. These results confirm high efficiency of the proposed approach to the spot identification. The proposed method of FISH image analysis improves the efficiency of detecting fluorescent signals in FISH images. The evaluation results are encouraging for further testing of the developed automatic system directed to application in medical practice. PMID:26694535

  15. Human L3L4 intervertebral disc mean 3D shape, modes of variation, and their relationship to degeneration

    PubMed Central

    Peloquin, John M.; Yoder, Jonathon H.; Jacobs, Nathan T.; Moon, Sung M.; Wright, Alexander C.; Vresilovic, Edward J.; Elliott, Dawn M.

    2014-01-01

    Intervertebral disc mechanics are affected by both disc shape and disc degeneration, which in turn each affect the other; disc mechanics additionally have a role in the etiology of disc degeneration. Finite element analysis (FEA) is a favored tool to investigate these relationships, but limited data for intervertebral disc 3D shape has forced the use of simplified or single-subject geometries, with the effect of inter-individual shape variation investigated only in specialized studies. Similarly, most data on disc shape variation with degeneration is based on 2D mid-sagittal images, which incompletely define 3D shape changes. Therefore, the objective of this study was to quantify inter-individual disc shape variation in 3D, classify this variation into independently-occurring modes using a statistical shape model, and identify correlations between disc shape and degeneration. Three-dimensional disc shapes were obtained from MRI of 13 human male cadaver L3L4 discs. An average disc shape and four major modes of shape variation (representing 90% of the variance) were identified. The first mode represented disc axial area and was significantly correlated to degeneration (R2 = 0.44), indicating larger axial area in degenerate discs. Disc height variation occurred in three distinct modes, each also involving non-height variation. The statistical shape model provides an average L3L4 disc shape for FEA that is fully defined in 3D, and makes it convenient to generate a set of shapes with which to represent aggregate inter-individual variation. Degeneration grade-specific shapes can also be generated. To facilitate application, the model is included in this paper’s supplemental content. PMID:24792581

  16. Development of an algorithm to measure defect geometry using a 3D laser scanner

    NASA Astrophysics Data System (ADS)

    Kilambi, S.; Tipton, S. M.

    2012-08-01

    Current fatigue life prediction models for coiled tubing (CT) require accurate measurements of the defect geometry. Three-dimensional (3D) laser imaging has shown promise toward becoming a nondestructive, non-contacting method of surface defect characterization. Laser imaging provides a detailed photographic image of a flaw, in addition to a detailed 3D surface map from which its critical dimensions can be measured. This paper describes algorithms to determine defect characteristics, specifically depth, width, length and projected cross-sectional area. Curve-fitting methods were compared and implicit algebraic fits have higher probability of convergence compared to explicit geometric fits. Among the algebraic fits, the Taubin circle fit has the least error. The algorithm was able to extract the dimensions of the flaw geometry from the scanned data of CT to within a tolerance of about 0.127 mm, close to the tolerance specified for the laser scanner itself, compared to measurements made using traveling microscopes. The algorithm computes the projected surface area of the flaw, which could previously only be estimated from the dimension measurements and the assumptions made about cutter shape. Although shadows compromised the accuracy of the shape characterization, especially for deep and narrow flaws, the results indicate that the algorithm with laser scanner can be used for non-destructive evaluation of CT in the oil field industry. Further work is needed to improve accuracy, to eliminate shadow effects and to reduce radial deviation.

  17. Object Recognition in Flight: How Do Bees Distinguish between 3D Shapes?

    PubMed

    Werner, Annette; Stürzl, Wolfgang; Zanker, Johannes

    2016-01-01

    Honeybees (Apis mellifera) discriminate multiple object features such as colour, pattern and 2D shape, but it remains unknown whether and how bees recover three-dimensional shape. Here we show that bees can recognize objects by their three-dimensional form, whereby they employ an active strategy to uncover the depth profiles. We trained individual, free flying honeybees to collect sugar water from small three-dimensional objects made of styrofoam (sphere, cylinder, cuboids) or folded paper (convex, concave, planar) and found that bees can easily discriminate between these stimuli. We also tested possible strategies employed by the bees to uncover the depth profiles. For the card stimuli, we excluded overall shape and pictorial features (shading, texture gradients) as cues for discrimination. Lacking sufficient stereo vision, bees are known to use speed gradients in optic flow to detect edges; could the bees apply this strategy also to recover the fine details of a surface depth profile? Analysing the bees' flight tracks in front of the stimuli revealed specific combinations of flight maneuvers (lateral translations in combination with yaw rotations), which are particularly suitable to extract depth cues from motion parallax. We modelled the generated optic flow and found characteristic patterns of angular displacement corresponding to the depth profiles of our stimuli: optic flow patterns from pure translations successfully recovered depth relations from the magnitude of angular displacements, additional rotation provided robust depth information based on the direction of the displacements; thus, the bees flight maneuvers may reflect an optimized visuo-motor strategy to extract depth structure from motion signals. The robustness and simplicity of this strategy offers an efficient solution for 3D-object-recognition without stereo vision, and could be employed by other flying insects, or mobile robots. PMID:26886006

  18. Object Recognition in Flight: How Do Bees Distinguish between 3D Shapes?

    PubMed Central

    Werner, Annette; Stürzl, Wolfgang; Zanker, Johannes

    2016-01-01

    Honeybees (Apis mellifera) discriminate multiple object features such as colour, pattern and 2D shape, but it remains unknown whether and how bees recover three-dimensional shape. Here we show that bees can recognize objects by their three-dimensional form, whereby they employ an active strategy to uncover the depth profiles. We trained individual, free flying honeybees to collect sugar water from small three-dimensional objects made of styrofoam (sphere, cylinder, cuboids) or folded paper (convex, concave, planar) and found that bees can easily discriminate between these stimuli. We also tested possible strategies employed by the bees to uncover the depth profiles. For the card stimuli, we excluded overall shape and pictorial features (shading, texture gradients) as cues for discrimination. Lacking sufficient stereo vision, bees are known to use speed gradients in optic flow to detect edges; could the bees apply this strategy also to recover the fine details of a surface depth profile? Analysing the bees’ flight tracks in front of the stimuli revealed specific combinations of flight maneuvers (lateral translations in combination with yaw rotations), which are particularly suitable to extract depth cues from motion parallax. We modelled the generated optic flow and found characteristic patterns of angular displacement corresponding to the depth profiles of our stimuli: optic flow patterns from pure translations successfully recovered depth relations from the magnitude of angular displacements, additional rotation provided robust depth information based on the direction of the displacements; thus, the bees flight maneuvers may reflect an optimized visuo-motor strategy to extract depth structure from motion signals. The robustness and simplicity of this strategy offers an efficient solution for 3D-object-recognition without stereo vision, and could be employed by other flying insects, or mobile robots. PMID:26886006

  19. 3D shape analysis of the brain's third ventricle using a midplane encoded symmetric template model

    PubMed Central

    Kim, Jaeil; Valdés Hernández, Maria del C.; Royle, Natalie A.; Maniega, Susana Muñoz; Aribisala, Benjamin S.; Gow, Alan J.; Bastin, Mark E.; Deary, Ian J.; Wardlaw, Joanna M.; Park, Jinah

    2016-01-01

    Background Structural changes of the brain's third ventricle have been acknowledged as an indicative measure of the brain atrophy progression in neurodegenerative and endocrinal diseases. To investigate the ventricular enlargement in relation to the atrophy of the surrounding structures, shape analysis is a promising approach. However, there are hurdles in modeling the third ventricle shape. First, it has topological variations across individuals due to the inter-thalamic adhesion. In addition, as an interhemispheric structure, it needs to be aligned to the midsagittal plane to assess its asymmetric and regional deformation. Method To address these issues, we propose a model-based shape assessment. Our template model of the third ventricle consists of a midplane and a symmetric mesh of generic shape. By mapping the template's midplane to the individuals’ brain midsagittal plane, we align the symmetric mesh on the midline of the brain before quantifying the third ventricle shape. To build the vertex-wise correspondence between the individual third ventricle and the template mesh, we employ a minimal-distortion surface deformation framework. In addition, to account for topological variations, we implement geometric constraints guiding the template mesh to have zero width where the inter-thalamic adhesion passes through, preventing vertices crossing between left and right walls of the third ventricle. The individual shapes are compared using a vertex-wise deformity from the symmetric template. Results Experiments on imaging and demographic data from a study of aging showed that our model was sensitive in assessing morphological differences between individuals in relation to brain volume (i.e. proxy for general brain atrophy), gender and the fluid intelligence at age 72. It also revealed that the proposed method can detect the regional and asymmetrical deformation unlike the conventional measures: volume (median 1.95 ml, IQR 0.96 ml) and width of the third

  20. 3D mouse shape reconstruction based on phase-shifting algorithm for fluorescence molecular tomography imaging system.

    PubMed

    Zhao, Yue; Zhu, Dianwen; Baikejiang, Reheman; Li, Changqing

    2015-11-10

    This work introduces a fast, low-cost, robust method based on fringe pattern and phase shifting to obtain three-dimensional (3D) mouse surface geometry for fluorescence molecular tomography (FMT) imaging. We used two pico projector/webcam pairs to project and capture fringe patterns from different views. We first calibrated the pico projectors and the webcams to obtain their system parameters. Each pico projector/webcam pair had its own coordinate system. We used a cylindrical calibration bar to calculate the transformation matrix between these two coordinate systems. After that, the pico projectors projected nine fringe patterns with a phase-shifting step of 2π/9 onto the surface of a mouse-shaped phantom. The deformed fringe patterns were captured by the corresponding webcam respectively, and then were used to construct two phase maps, which were further converted to two 3D surfaces composed of scattered points. The two 3D point clouds were further merged into one with the transformation matrix. The surface extraction process took less than 30 seconds. Finally, we applied the Digiwarp method to warp a standard Digimouse into the measured surface. The proposed method can reconstruct the surface of a mouse-sized object with an accuracy of 0.5 mm, which we believe is sufficient to obtain a finite element mesh for FMT imaging. We performed an FMT experiment using a mouse-shaped phantom with one embedded fluorescence capillary target. With the warped finite element mesh, we successfully reconstructed the target, which validated our surface extraction approach. PMID:26560789

  1. 3D granulometry: grain-scale shape and size distribution from point cloud dataset of river environments

    NASA Astrophysics Data System (ADS)

    Steer, Philippe; Lague, Dimitri; Gourdon, Aurélie; Croissant, Thomas; Crave, Alain

    2016-04-01

    The grain-scale morphology of river sediments and their size distribution are important factors controlling the efficiency of fluvial erosion and transport. In turn, constraining the spatial evolution of these two metrics offer deep insights on the dynamics of river erosion and sediment transport from hillslopes to the sea. However, the size distribution of river sediments is generally assessed using statistically-biased field measurements and determining the grain-scale shape of river sediments remains a real challenge in geomorphology. Here we determine, with new methodological approaches based on the segmentation and geomorphological fitting of 3D point cloud dataset, the size distribution and grain-scale shape of sediments located in river environments. Point cloud segmentation is performed using either machine-learning algorithms or geometrical criterion, such as local plan fitting or curvature analysis. Once the grains are individualized into several sub-clouds, each grain-scale morphology is determined using a 3D geometrical fitting algorithm applied on the sub-cloud. If different geometrical models can be conceived and tested, only ellipsoidal models were used in this study. A phase of results checking is then performed to remove grains showing a best-fitting model with a low level of confidence. The main benefits of this automatic method are that it provides 1) an un-biased estimate of grain-size distribution on a large range of scales, from centimeter to tens of meters; 2) access to a very large number of data, only limited by the number of grains in the point-cloud dataset; 3) access to the 3D morphology of grains, in turn allowing to develop new metrics characterizing the size and shape of grains. The main limit of this method is that it is only able to detect grains with a characteristic size greater than the resolution of the point cloud. This new 3D granulometric method is then applied to river terraces both in the Poerua catchment in New-Zealand and

  2. Quantifying floral shape variation in 3D using microcomputed tomography: a case study of a hybrid line between actinomorphic and zygomorphic flowers

    PubMed Central

    Wang, Chun-Neng; Hsu, Hao-Chun; Wang, Cheng-Chun; Lee, Tzu-Kuei; Kuo, Yan-Fu

    2015-01-01

    The quantification of floral shape variations is difficult because flower structures are both diverse and complex. Traditionally, floral shape variations are quantified using the qualitative and linear measurements of two-dimensional (2D) images. The 2D images cannot adequately describe flower structures, and thus lead to unsatisfactory discrimination of the flower shape. This study aimed to acquire three-dimensional (3D) images by using microcomputed tomography (μCT) and to examine the floral shape variations by using geometric morphometrics (GM). To demonstrate the advantages of the 3D-μCT-GM approach, we applied the approach to a second-generation population of florist's gloxinia (Sinningia speciosa) crossed from parents of zygomorphic and actinomorphic flowers. The flowers in the population considerably vary in size and shape, thereby served as good materials to test the applicability of the proposed phenotyping approach. Procedures were developed to acquire 3D volumetric flower images using a μCT scanner, to segment the flower regions from the background, and to select homologous characteristic points (i.e., landmarks) from the flower images for the subsequent GM analysis. The procedures identified 95 landmarks for each flower and thus improved the capability of describing and illustrating the flower shapes, compared with typically lower number of landmarks in 2D analyses. The GM analysis demonstrated that flower opening and dorsoventral symmetry were the principal shape variations of the flowers. The degrees of flower opening and corolla asymmetry were then subsequently quantified directly from the 3D flower images. The 3D-μCT-GM approach revealed shape variations that could not be identified using typical 2D approaches and accurately quantified the flower traits that presented a challenge in 2D images. The approach opens new avenues to investigate floral shape variations. PMID:26442038

  3. Using the auxiliary camera for system calibration of 3D measurement by digital speckle

    NASA Astrophysics Data System (ADS)

    Xue, Junpeng; Su, Xianyu; Zhang, Qican

    2014-06-01

    The study of 3D shape measurement by digital speckle temporal sequence correlation have drawn a lot of attention by its own advantages, however, the measurement mainly for depth z-coordinate, horizontal physical coordinate (x, y) are usually marked as image pixel coordinate. In this paper, a new approach for the system calibration is proposed. With an auxiliary camera, we made up the temporary binocular vision system, which are used for the calibration of horizontal coordinates (mm) while the temporal sequence reference-speckle-sets are calibrated. First, the binocular vision system has been calibrated using the traditional method. Then, the digital speckles are projected on the reference plane, which is moved by equal distance in the direction of depth, temporal sequence speckle images are acquired with camera as reference sets. When the reference plane is in the first position and final position, crossed fringe pattern are projected to the plane respectively. The control points of pixel coordinates are extracted by Fourier analysis from the images, and the physical coordinates are calculated by the binocular vision. The physical coordinates corresponding to each pixel of the images are calculated by interpolation algorithm. Finally, the x and y corresponding to arbitrary depth value z are obtained by the geometric formula. Experiments prove that our method can fast and flexibly measure the 3D shape of an object as point cloud.

  4. KOALA: 3-D shape of asteroids from multi-data inversion

    NASA Astrophysics Data System (ADS)

    Carry, B.; Kaasalainen, M.; Merline, W. J.; Drummond, J. D.; Durech, J.; Berthier, J.; Conrad, A.

    2011-10-01

    We describe our on-going observing program to determine the physical properties of asteroids from groundbased facilities. We combine disk-resolved images from adaptive optics, optical lightcurves, and stellar occultations to put tighter constraints on the spin, 3-D shape, and size of asteroids. We will discuss the relevance of the determination of physical properties to help understand the asteroid population (e.g., density, composition, and non-gravitational forces). We will then briefly describe our multi-data inversion algorithm KOALA (Carry et al. 2010a, Kaasalainen 2011, see also Kaasalainen et al., same meeting), which allows the determination of certain physical properties of an asteroid from the combination of different techniques of observation. A comparison of results obtained with KOALA on asteroid (21) Lutetia, prior to the ESA Rosetta flyby, with the high spatial resolution images returned from that flyby, will then be presented, showing the high accuracy of KOALA inversion. Finally, we will describe our current development of the algorithm, and focus on examples of other asteroids currently being studied with KOALA.

  5. General application of rapid 3-D digitizing and tool path generation for complex shapes

    SciTech Connect

    Kwok, K.S.; Loucks, C.S.; Driessen, B.J.

    1997-09-01

    A system for automatic tool path generation was developed at Sandia National Laboratories for finish machining operations. The system consists of a commercially available 5-axis milling machine controlled by Sandia developed software. This system was used to remove overspray on cast turbine blades. A laser-based, structured-light sensor, mounted on a tool holder, is used to collect 3D data points around the surface of the turbine blade. Using the digitized model of the blade, a tool path is generated which will drive a 0.375 inch grinding pin around the tip of the blade. A fuzzified digital filter was developed to properly eliminate false sensor readings caused by burrs, holes and overspray. The digital filter was found to successfully generate the correct tool path for a blade with intentionally scanned holes and defects. The fuzzified filter improved the computation efficiency by a factor of 25. For application to general parts, an adaptive scanning algorithm was developed and presented with simulation and experimental results. A right pyramid and an ellipsoid were scanned successfully with the adaptive algorithm in simulation studies. In actual experiments, a nose cone and a turbine blade were successfully scanned. A complex shaped turbine blade was successfully scanned and finished machined using these algorithms.

  6. Temperature maps measurements on 3D surfaces with infrared thermography

    NASA Astrophysics Data System (ADS)

    Cardone, Gennaro; Ianiro, Andrea; Dello Ioio, Gennaro; Passaro, Andrea

    2012-02-01

    The use of the infrared camera as a temperature transducer in wind tunnel applications is convenient and widespread. Nevertheless, the infrared data are available in the form of 2D images while the observed surfaces are often not planar and the reconstruction of temperature maps over them is a critical task. In this work, after recalling the principles of IR thermography, a methodology to rebuild temperature maps on the surfaces of 3D object is proposed. In particular, an optical calibration is applied to the IR camera by means of a novel target plate with control points. The proposed procedure takes also into account the directional emissivity by estimating the viewing angle. All the needed steps are described and analyzed. The advantages given by the proposed method are shown with an experiment in a hypersonic wind tunnel.

  7. Generation of 3D shape, density, cortical thickness and finite element mesh of proximal femur from a DXA image.

    PubMed

    Väänänen, Sami P; Grassi, Lorenzo; Flivik, Gunnar; Jurvelin, Jukka S; Isaksson, Hanna

    2015-08-01

    Areal bone mineral density (aBMD), as measured by dual-energy X-ray absorptiometry (DXA), predicts hip fracture risk only moderately. Simulation of bone mechanics based on DXA imaging of the proximal femur, may help to improve the prediction accuracy. Therefore, we collected three (1-3) image sets, including CT images and DXA images of 34 proximal cadaver femurs (set 1, including 30 males, 4 females), 35 clinical patient CT images of the hip (set 2, including 27 males, 8 females) and both CT and DXA images of clinical patients (set 3, including 12 female patients). All CT images were segmented manually and landmarks were placed on both femurs and pelvises. Two separate statistical appearance models (SAMs) were built using the CT images of the femurs and pelvises in sets 1 and 2, respectively. The 3D shape of the femur was reconstructed from the DXA image by matching the SAMs with the DXA images. The orientation and modes of variation of the SAMs were adjusted to minimize the sum of the absolute differences between the projection of the SAMs and a DXA image. The mesh quality and the location of the SAMs with respect to the manually placed control points on the DXA image were used as additional constraints. Then, finite element (FE) models were built from the reconstructed shapes. Mean point-to-surface distance between the reconstructed shape and CT image was 1.0 mm for cadaver femurs in set 1 (leave-one-out test) and 1.4 mm for clinical subjects in set 3. The reconstructed volumetric BMD showed a mean absolute difference of 140 and 185 mg/cm(3) for set 1 and set 3 respectively. The generation of the SAM and the limitation of using only one 2D image were found to be the most significant sources of errors in the shape reconstruction. The noise in the DXA images had only small effect on the accuracy of the shape reconstruction. DXA-based FE simulation was able to explain 85% of the CT-predicted strength of the femur in stance loading. The present method can be used to

  8. 2D measurements of cup orientation are less reliable than 3D measurements

    PubMed Central

    Smyth, Niall; Cobb, Justin P; Hart, Alister J

    2015-01-01

    Background and purpose 2D analysis of metal-on-metal (MoM) hip arthroplasty (HA) has been conducted in several large series on conventional radiographs with the use of Ein Bild Roentegen Analyse (EBRA) software, but there have been no comparisons with 3D analysis in the literature. The main aim of this study was to quantify the agreement in measurements of cup version of large-diameter MoM hips obtained by EBRA and by 3D computed tomography (3D-CT). The secondary aim was to quantify the agreement for cup inclination. Lastly, we wanted to determine the inter- and intra-observer reliability of both methods. Patients and methods 87 MoM hips in 81 patients were analyzed for cup inclination and version in 2D on conventional radiographs using EBRA software. The results were compared with 3D measurements using CT. Results Cup version was underestimated by EBRA when compared to 3D-CT, by 6° on average with the pelvis supine and by 8° on average with the pelvis orientated to the anterior pelvic plane (APP). For inclination, the mean difference was no more than 1°. 53% of hips were within a 10° safe zone of 45° inclination and 20° version when measured by 3D-CT with the pelvis supine (and 54% with the pelvis in the APP). The proportion was only 24% when measured by EBRA. Inter- and intra-observer reliability of cup version is poorer using 2D analysis than when using 3D-CT. Interpretation Errors in version in 2D were due to the difficulty in delineating the cup rim, which was obscured by a large-diameter metal head of the same radio-opacity. This can be overcome with 3D analysis. The present study demonstrates that measurements using EBRA have poor agreement and are less reliable than those with 3D-CT when measuring cup version and inclination in MoM hips. PMID:25674698

  9. Combining 3D optical imaging and dual energy absorptiometry to measure three compositional components

    NASA Astrophysics Data System (ADS)

    Malkov, Serghei; Shepherd, John

    2014-02-01

    We report on the design of the technique combining 3D optical imaging and dual-energy absorptiometry body scanning to estimate local body area compositions of three compartments. Dual-energy attenuation and body shape measures are used together to solve for the three compositional tissue thicknesses: water, lipid, and protein. We designed phantoms with tissue-like properties as our reference standards for calibration purposes. The calibration was created by fitting phantom values using non-linear regression of quadratic and truncated polynomials. Dual-energy measurements were performed on tissue-mimicking phantoms using a bone densitometer unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the biological compositional compartments. The components for the solid phantom were tested and their high energy/low energy attenuation ratios are in good correspondent to water, lipid, and protein for the densitometer x-ray region. The three-dimensional body shape was reconstructed from the depth maps generated by Microsoft Kinect for Windows. We used open-source Point Cloud Library and freeware software to produce dense point clouds. Accuracy and precision of compositional and thickness measures were calculated. The error contributions due to two modalities were estimated. The preliminary phantom composition and shape measurements are found to demonstrate the feasibility of the method proposed.

  10. Combining 3D optical imaging and dual energy absorptiometry to measure three compositional components

    PubMed Central

    Malkov, Serghei; Shepherd, John

    2014-01-01

    We report on the design of the technique combining 3D optical imaging and dual-energy absorptiometry body scanning to estimate local body area compositions of three compartments. Dual-energy attenuation and body shape measures are used together to solve for the three compositional tissue thicknesses: water, lipid, and protein. We designed phantoms with tissue-like properties as our reference standards for calibration purposes. The calibration was created by fitting phantom values using non-linear regression of quadratic and truncated polynomials. Dual-energy measurements were performed on tissue-mimicking phantoms using a bone densitometer unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the biological compositional compartments. The components for the solid phantom were tested and their high energy/low energy attenuation ratios are in good correspondent to water, lipid, and protein for the densitometer x-ray region. The three-dimensional body shape was reconstructed from the depth maps generated by Microsoft Kinect for Windows. We used open-source Point Cloud Library and freeware software to produce dense point clouds. Accuracy and precision of compositional and thickness measures were calculated. The error contributions due to two modalities were estimated. The preliminary phantom composition and shape measurements are found to demonstrate the feasibility of the method proposed. PMID:25083118

  11. 3D bone mineral density distribution and shape reconstruction of the proximal femur from a single simulated DXA image: an in vitro study

    NASA Astrophysics Data System (ADS)

    Whitmarsh, Tristan; Humbert, Ludovic; De Craene, Mathieu; del Río Barquero, Luis M.; Fritscher, Karl; Schubert, Rainer; Eckstein, Felix; Link, Thomas; Frangi, Alejandro F.

    2010-03-01

    Area Bone Mineral Density (aBMD) measured by Dual-energy X-ray Absorptiometry (DXA) is an established criterion in the evaluation of hip fracture risk. The evaluation from these planar images, however, is limited to 2D while it has been shown that proper 3D assessment of both the shape and the Bone Mineral Density (BMD) distribution improves the fracture risk estimation. In this work we present a method to reconstruct both the 3D bone shape and 3D BMD distribution of the proximal femur from a single DXA image. A statistical model of shape and a separate statistical model of the BMD distribution were automatically constructed from a set of Quantitative Computed Tomography (QCT) scans. The reconstruction method incorporates a fully automatic intensity based 3D-2D registration process, maximizing the similarity between the DXA and a digitally reconstructed radiograph of the combined model. For the construction of the models, an in vitro dataset of QCT scans of 60 anatomical specimens was used. To evaluate the reconstruction accuracy, experiments were performed on simulated DXA images from the QCT scans of 30 anatomical specimens. Comparisons between the reconstructions and the same subject QCT scans showed a mean shape accuracy of 1.2mm, and a mean density error of 81mg/cm3. The results show that this method is capable of accurately reconstructing both the 3D shape and 3D BMD distribution of the proximal femur from DXA images used in clinical routine, potentially improving the diagnosis of osteoporosis and fracture risk assessments at a low radiation dose and low cost.

  12. Uneven fringe projection for efficient calibration in high-resolution 3D shape metrology

    SciTech Connect

    Zhang Zonghua; Towers, Catherine E.; Towers, David P

    2007-08-20

    A novel uneven fringe projection technique is presented whereby nonuniformly spaced fringes are generated at a digital video projector to give evenly spaced fringes in the measurement volume. The proposed technique simplifies the relation between the measured phase and the object's depth independent of pixel position. This method needs just one coefficient set for calibration and depth calculation. With uneven fringe projection the shape data are referenced to a virtual plane instead of a physical reference plane, so an improved measurement with lower uncertainty is achieved. Further,the method can be combined with a radial lens distortion model. The theoretical foundation of the method is presented and experimentally validated to demonstrate the advantages of the uneven fringe projection approach compared with existing methods.Measurement results on a National Physical Laboratory (UK) 'step standard' confirm the measurement uncertainty using the proposed method.

  13. Measuring Fracture Properties of Meteorites: 3D Scans and Disruption Experiments.

    NASA Astrophysics Data System (ADS)

    Cotto-Figueroa, Desireé; Asphaug, Erik; Morris, Melissa A.; Garvie, Laurence

    2014-11-01

    The Arizona State University (ASU) Center for Meteorite Studies (CMS) houses over 30,000 specimens that represent almost every known meteorite type. A number of these are available for fragmentation experiments in small samples, but in most cases non-destructive experiments are desired in order to determine the fundamental mechanical properties of meteorites, and by extension, the Near-Earth Asteroids (NEAs) and other planetary bodies they derive from. We present results from an ongoing suite of measurements and experiments, featuring automated 3D topographic scans of a comprehensive suite of meteorites in the CMS collection, basic mechanical studies, and culminating in catastrophic fragmentation of four representative meteorites: Tamdakht (H5), Allende (CV3), Northwest Africa 869 (L3-6) and Chelyabinsk (LL5). Results will include high-resolution 3D color-shape models of meteorites, including specimens such as the 349g oriented and fusion crusted Martian (shergottite) Tissint, and the delicately fusion crusted and oriented 131g Whetstone Mountains (H5) ordinary chondrite. The 3D color-shape models will allow us to obtain basic physical properties (such as volume to derive density) and to derive fractal dimensions of fractured surfaces. Fractal dimension is closely related to the internal structural heterogeneity and fragmentation of the material, to macroscopic optical properties, and to rubble friction and cohesion. Freshly fractured surfaces of fragments that will result from catastrophic hypervelocity impact experiments will be subsequently scanned and analyzed in order to determine whether fractal dimension is preserved or if it changes with surface maturation.

  14. Model-based measurement of food portion size for image-based dietary assessment using 3D/2D registration

    NASA Astrophysics Data System (ADS)

    Chen, Hsin-Chen; Jia, Wenyan; Yue, Yaofeng; Li, Zhaoxin; Sun, Yung-Nien; Fernstrom, John D.; Sun, Mingui

    2013-10-01

    Dietary assessment is important in health maintenance and intervention in many chronic conditions, such as obesity, diabetes and cardiovascular disease. However, there is currently a lack of convenient methods for measuring the volume of food (portion size) in real-life settings. We present a computational method to estimate food volume from a single photographic image of food contained on a typical dining plate. First, we calculate the food location with respect to a 3D camera coordinate system using the plate as a scale reference. Then, the food is segmented automatically from the background in the image. Adaptive thresholding and snake modeling are implemented based on several image features, such as color contrast, regional color homogeneity and curve bending degree. Next, a 3D model representing the general shape of the food (e.g., a cylinder, a sphere, etc) is selected from a pre-constructed shape model library. The position, orientation and scale of the selected shape model are determined by registering the projected 3D model and the food contour in the image, where the properties of the reference are used as constraints. Experimental results using various realistically shaped foods with known volumes demonstrated satisfactory performance of our image-based food volume measurement method even if the 3D geometric surface of the food is not completely represented in the input image.

  15. Dynamic 3D shape of the plantar surface of the foot using coded structured light: a technical report

    PubMed Central

    2014-01-01

    Background The foot provides a crucial contribution to the balance and stability of the musculoskeletal system, and accurate foot measurements are important in applications such as designing custom insoles/footwear. With better understanding of the dynamic behavior of the foot, dynamic foot reconstruction techniques are surfacing as useful ways to properly measure the shape of the foot. This paper presents a novel design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Methods Engineering and clinical tests were carried out to test the accuracy and repeatability of the system. Accuracy experiments involved imaging a planar surface from different orientations and elevations and measuring the fitting errors of the data to a plane. Repeatability experiments were done using reconstructions from 27 different subjects, where for each one both right and left feet were reconstructed in static and dynamic conditions over two different days. Results The static accuracy of the system was found to be 0.3 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.4 mm (static case) and 2.8 mm (dynamic case). Conclusion The results obtained in the experiments show positive accuracy and repeatability results when compared to current literature. The design also shows to be superior to the systems available in the literature in several factors. Further studies need to be done to quantify the reliability of the system in clinical environments. PMID:24456711

  16. Fast optical 3D form measurement of aspheres including determination of thickness and wedge and decenter errors

    NASA Astrophysics Data System (ADS)

    Stover, E.; Berger, G.; Wendel, M.; Petter, J.

    2015-10-01

    A method for non-contact 3D form testing of aspheric surfaces including determination of decenter and wedge errors and lens thickness is presented. The principle is based on the absolute measurement capability of multi-wavelength interferometry (MWLI). The approach produces high density 3D shape information and geometric parameters at high accuracy in short measurement times. The system allows inspection of aspheres without restrictions in terms of spherical departures, of segmented and discontinuous optics. The optics can be polished or ground and made of opaque or transparent materials.

  17. Automatic building detection and 3D shape recovery from single monocular electro-optic imagery

    NASA Astrophysics Data System (ADS)

    Lavigne, Daniel A.; Saeedi, Parvaneh; Dlugan, Andrew; Goldstein, Norman; Zwick, Harold

    2007-04-01

    The extraction of 3D building geometric information from high-resolution electro-optical imagery is becoming a key element in numerous geospatial applications. Indeed, producing 3D urban models is a requirement for a variety of applications such as spatial analysis of urban design, military simulation, and site monitoring of a particular geographic location. However, almost all operational approaches developed over the years for 3D building reconstruction are semiautomated ones, where a skilled human operator is involved in the 3D geometry modeling of building instances, which results in a time-consuming process. Furthermore, such approaches usually require stereo image pairs, image sequences, or laser scanning of a specific geographic location to extract the 3D models from the imagery. Finally, with current techniques, the 3D geometric modeling phase may be characterized by the extraction of 3D building models with a low accuracy level. This paper describes the Automatic Building Detection (ABD) system and embedded algorithms currently under development. The ABD system provides a framework for the automatic detection of buildings and the recovery of 3D geometric models from single monocular electro-optic imagery. The system is designed in order to cope with multi-sensor imaging of arbitrary viewpoint variations, clutter, and occlusion. Preliminary results on monocular airborne and spaceborne images are provided. Accuracy assessment of detected buildings and extracted 3D building models from single airborne and spaceborne monocular imagery of real scenes are also addressed. Embedded algorithms are evaluated for their robustness to deal with relatively dense and complicated urban environments.

  18. Rapid and automatic 3D body measurement system based on a GPU-Steger line detector.

    PubMed

    Liu, Xingjian; Zhao, Hengshuang; Zhan, Guomin; Zhong, Kai; Li, Zhongwei; Chao, Yuhjin; Shi, Yusheng

    2016-07-20

    This paper proposes a rapid and automatic measurement system to acquire a 3D shape of a human body. A flexible calibration method was developed to decrease the complexity in system calibration. To reduce the computation cost, a GPU-Steger line detector was proposed to more rapidly detect the center of the laser pattern and at subpixel level. The processing time of line detection is significantly shortened by the GPU-Steger line detector, which can be over 110 times faster than that by CPU. The key technologies are introduced, and the experimental results are presented in this paper to illustrate the performance of the proposed system. The system can be used to measure human body surfaces with nonuniform reflectance such as hair, skin, and clothes with rich texture. PMID:27463902

  19. Validation of 3-D Ice Accretion Measurement Methodology for Experimental Aerodynamic Simulation

    NASA Technical Reports Server (NTRS)

    Broeren, Andy P.; Addy, Harold E., Jr.; Lee, Sam; Monastero, Marianne C.

    2015-01-01

    Determining the adverse aerodynamic effects due to ice accretion often relies on dry-air wind-tunnel testing of artificial, or simulated, ice shapes. Recent developments in ice-accretion documentation methods have yielded a laser-scanning capability that can measure highly three-dimensional (3-D) features of ice accreted in icing wind tunnels. The objective of this paper was to evaluate the aerodynamic accuracy of ice-accretion simulations generated from laser-scan data. Ice-accretion tests were conducted in the NASA Icing Research Tunnel using an 18-in. chord, two-dimensional (2-D) straight wing with NACA 23012 airfoil section. For six ice-accretion cases, a 3-D laser scan was performed to document the ice geometry prior to the molding process. Aerodynamic performance testing was conducted at the University of Illinois low-speed wind tunnel at a Reynolds number of 1.8 × 10(exp 6) and a Mach number of 0.18 with an 18-in. chord NACA 23012 airfoil model that was designed to accommodate the artificial ice shapes. The ice-accretion molds were used to fabricate one set of artificial ice shapes from polyurethane castings. The laser-scan data were used to fabricate another set of artificial ice shapes using rapid prototype manufacturing such as stereolithography. The iced-airfoil results with both sets of artificial ice shapes were compared to evaluate the aerodynamic simulation accuracy of the laser-scan data. For five of the six ice-accretion cases, there was excellent agreement in the iced-airfoil aerodynamic performance between the casting and laser-scan based simulations. For example, typical differences in iced-airfoil maximum lift coefficient were less than 3 percent with corresponding differences in stall angle of approximately 1 deg or less. The aerodynamic simulation accuracy reported in this paper has demonstrated the combined accuracy of the laser-scan and rapid-prototype manufacturing approach to simulating ice accretion for a NACA 23012 airfoil. For several

  20. Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

    SciTech Connect

    Baek, Jihye; Huh, Jangyoung; Hyun An, So; Oh, Yoonjin; Kim, Myungsoo; Kim, DongYoung; Chung, Kwangzoo; Cho, Sungho; Lee, Rena

    2013-02-15

    Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

  1. Perceptual quality measurement of 3D images based on binocular vision.

    PubMed

    Zhou, Wujie; Yu, Lu

    2015-07-20

    Three-dimensional (3D) technology has become immensely popular in recent years and widely adopted in various applications. Hence, perceptual quality measurement of symmetrically and asymmetrically distorted 3D images has become an important, fundamental, and challenging issue in 3D imaging research. In this paper, we propose a binocular-vision-based 3D image-quality measurement (IQM) metric. Consideration of the 3D perceptual properties of the primary visual cortex (V1) and the higher visual areas (V2) for 3D-IQM is the major technical contribution to this research. To be more specific, first, the metric simulates the receptive fields of complex cells (V1) using binocular energy response and binocular rivalry response and the higher visual areas (V2) using local binary patterns features. Then, three similarity scores of 3D perceptual properties between the reference and distorted 3D images are measured. Finally, by using support vector regression, three similarity scores are integrated into an overall 3D quality score. Experimental results for two public benchmark databases demonstrate that, in comparison with most current 2D and 3D metrics, the proposed metric achieves significantly higher consistency in alignment with subjective fidelity ratings. PMID:26367842

  2. Face recognition using 3D facial shape and color map information: comparison and combination

    NASA Astrophysics Data System (ADS)

    Godil, Afzal; Ressler, Sandy; Grother, Patrick

    2004-08-01

    In this paper, we investigate the use of 3D surface geometry for face recognition and compare it to one based on color map information. The 3D surface and color map data are from the CAESAR anthropometric database. We find that the recognition performance is not very different between 3D surface and color map information using a principal component analysis algorithm. We also discuss the different techniques for the combination of the 3D surface and color map information for multi-modal recognition by using different fusion approaches and show that there is significant improvement in results. The effectiveness of various techniques is compared and evaluated on a dataset with 200 subjects in two different positions.

  3. Local 3D matrix confinement determines division axis through cell shape

    PubMed Central

    He, Lijuan; Chen, Weitong; Wu, Pei-Hsun; Jimenez, Angela; Wong, Bin Sheng; San, Angela; Konstantopoulos, Konstantinos; Wirtz, Denis

    2016-01-01

    How the division axis is determined in mammalian cells embedded in three-dimensional (3D) matrices remains elusive, despite that many types of cells divide in 3D environments. Cells on two-dimensional (2D) substrates typically round up completely to divide. Here, we show that in 3D collagen matrices, mammalian cells such as HT1080 human fibrosarcoma and MDA-MB-231 breast cancer cells exhibit division modes distinct from their Counterparts on 2D substrates, with a markedly higher fraction of cells remaining highly elongated through mitosis in 3D matrices. The long axis of elongated mitotic cells accurately predicts the division axis, independently of matrix density and cell-matrix interactions. This 3D-specific elongated division mode is determined by the local confinement produced by the matrix and the ability of cells to protrude and locally remodel the matrix via β1 integrin. Elongated division is readily recapitulated using collagen-coated microfabricated channels. Cells depleted of β1 integrin still divide in the elongated mode in microchannels, suggesting that 3D confinement is sufficient to induce the elongated cell-division phenotype. PMID:26515603

  4. General approach for the description of optical 3D measuring systems

    NASA Astrophysics Data System (ADS)

    Andrae, Peter; Jueptner, Werner P. O.; Kebbel, Volker; Osten, Wolfgang

    1997-07-01

    In this paper a general geometric description of the optical methods for 3D coordinate measurement is presented. Similar to holographic interferometry this new approach is based on the concept of measuring sensitivity. As a special case the derived basic relation is applied to the fringe projection technique using a physical model of this measurement method. Moreover a geometric 3D model that contributes to a dramatic reduction of systematic distortions of measured 3D coordinates is presented. On the one hand this model is sufficiently general but on the other hand still easy to handle. It permits an explicit and direct determination of 3D coordinates from primary measuring data as well as a calibration of the measuring set-up using linear identification methods mainly. The described 3D model can be applied also with advantage to multiview registration tasks.

  5. 3-D Measurement and Visualization of Electrical Propagation on Heart Surface

    NASA Astrophysics Data System (ADS)

    Lin, Shien-Fong; Wikswo, John P.

    1997-11-01

    Optical recording of the cardiac transmembrane potential (Vm) has recently become a powerful tool to reveal patterns of electrical wave front dynamics on the heart surface. The optical mapping techniques have been previously applied to observe a portion of the heart due to its 3-D geometry. We extended our 2-D optical mapping technique to include one front view and two back mirror views for measuring and visualizing the transmembrane potential distribution simultaneously over entire surface of an isolated rabbit heart. The heart was illuminated with an argon laser delivered through an optical fiber bundle consisting of seven 1-mm fibers. These fibers were positioned around the heart to induce a near-uniform fluorescence intensity distribution on the heart surface. A single high-speed CCD camera with a long depth of field recorded the laser-stimulated epifluorescence from all three views in a single frame. Sequences of 100 to 600 frames of 12-bit/pixel digital images were recorded during regular pacing or induced ventricular fibrillation at 335 frames/second. Image processing then yielded the Vm distribution at a resolution of 128x64 pixels/frame. The propagating wave front images were obtained by subtracting two subsequent Vm images. The geometry of the heart was obtained by profilometry. The wave front information obtained from image processing could be texture-mapped to the heart geometry for visualization. Our 3-D imaging technique provides simultaneous, dynamic information of wave front activation and propagation over entire heart surface, and thereby can offer a more complete knowledge of wave front dynamics in a whole heart model. Future work involves automatic procedure for digitizing the heart shape and measuring the wave front dimensions using the 3-D geometry.

  6. Fish body surface data measurement based on 3D digital image correlation

    NASA Astrophysics Data System (ADS)

    Jiang, Ming; Qian, Chen; Yang, Wenkai

    2016-01-01

    To film the moving fish in the glass tank, light will be bent at the interface of air and glass, glass and water. Based on binocular stereo vision and refraction principle, we establish a mathematical model of 3D image correlation to reconstruct the 3D coordinates of samples in the water. Marking speckle in fish surface, a series of real-time speckle images of swimming fish will be obtained by two high-speed cameras, and instantaneous 3D shape, strain, displacement etc. of fish will be reconstructed.

  7. Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape models

    NASA Astrophysics Data System (ADS)

    Neubert, A.; Fripp, J.; Engstrom, C.; Schwarz, R.; Lauer, L.; Salvado, O.; Crozier, S.

    2012-12-01

    Recent advances in high resolution magnetic resonance (MR) imaging of the spine provide a basis for the automated assessment of intervertebral disc (IVD) and vertebral body (VB) anatomy. High resolution three-dimensional (3D) morphological information contained in these images may be useful for early detection and monitoring of common spine disorders, such as disc degeneration. This work proposes an automated approach to extract the 3D segmentations of lumbar and thoracic IVDs and VBs from MR images using statistical shape analysis and registration of grey level intensity profiles. The algorithm was validated on a dataset of volumetric scans of the thoracolumbar spine of asymptomatic volunteers obtained on a 3T scanner using the relatively new 3D T2-weighted SPACE pulse sequence. Manual segmentations and expert radiological findings of early signs of disc degeneration were used in the validation. There was good agreement between manual and automated segmentation of the IVD and VB volumes with the mean Dice scores of 0.89 ± 0.04 and 0.91 ± 0.02 and mean absolute surface distances of 0.55 ± 0.18 mm and 0.67 ± 0.17 mm respectively. The method compares favourably to existing 3D MR segmentation techniques for VBs. This is the first time IVDs have been automatically segmented from 3D volumetric scans and shape parameters obtained were used in preliminary analyses to accurately classify (100% sensitivity, 98.3% specificity) disc abnormalities associated with early degenerative changes.

  8. Characterization of linearity and uniformity of fiber-based endoscopes for 3D combustion measurements.

    PubMed

    Kang, MinWook; Lei, Qingchun; Ma, Lin

    2014-09-10

    This work reports the application of fiber-based endoscopes (FBEs) for instantaneous three-dimensional (3D) flow and combustion measurements, with an emphasis on characterizing the linearity and uniformity of the FBEs and exploring their potential for obtaining quantitative measurements. Controlled experiments were performed using a uniform illuminator to characterize the linearity and uniformity of the FBEs. Based on such characterization, 3D instantaneous measurements of flames were demonstrated by a combined use of FBEs and tomography. To obtain 3D flame measurement, 3D tomographic reconstructions were made from multiple projections of the target flames collected from various orientations by the FBEs. The results illustrate the potential of FBEs to obtain quantitative 3D flow and combustion measurements and also the advantages FBEs offer, including overcoming optical access restrictions and equipment cost. PMID:25321676

  9. 3D active shape models of human brain structures: application to patient-specific mesh generation

    NASA Astrophysics Data System (ADS)

    Ravikumar, Nishant; Castro-Mateos, Isaac; Pozo, Jose M.; Frangi, Alejandro F.; Taylor, Zeike A.

    2015-03-01

    The use of biomechanics-based numerical simulations has attracted growing interest in recent years for computer-aided diagnosis and treatment planning. With this in mind, a method for automatic mesh generation of brain structures of interest, using statistical models of shape (SSM) and appearance (SAM), for personalised computational modelling is presented. SSMs are constructed as point distribution models (PDMs) while SAMs are trained using intensity profiles sampled from a training set of T1-weighted magnetic resonance images. The brain structures of interest are, the cortical surface (cerebrum, cerebellum & brainstem), lateral ventricles and falx-cerebri membrane. Two methods for establishing correspondences across the training set of shapes are investigated and compared (based on SSM quality): the Coherent Point Drift (CPD) point-set registration method and B-spline mesh-to-mesh registration method. The MNI-305 (Montreal Neurological Institute) average brain atlas is used to generate the template mesh, which is deformed and registered to each training case, to establish correspondence over the training set of shapes. 18 healthy patients' T1-weightedMRimages form the training set used to generate the SSM and SAM. Both model-training and model-fitting are performed over multiple brain structures simultaneously. Compactness and generalisation errors of the BSpline-SSM and CPD-SSM are evaluated and used to quantitatively compare the SSMs. Leave-one-out cross validation is used to evaluate SSM quality in terms of these measures. The mesh-based SSM is found to generalise better and is more compact, relative to the CPD-based SSM. Quality of the best-fit model instance from the trained SSMs, to test cases are evaluated using the Hausdorff distance (HD) and mean absolute surface distance (MASD) metrics.

  10. Benchmarking of HPCC: A novel 3D molecular representation combining shape and pharmacophoric descriptors for efficient molecular similarity assessments.

    PubMed

    Karaboga, Arnaud S; Petronin, Florent; Marchetti, Gino; Souchet, Michel; Maigret, Bernard

    2013-04-01

    Since 3D molecular shape is an important determinant of biological activity, designing accurate 3D molecular representations is still of high interest. Several chemoinformatic approaches have been developed to try to describe accurate molecular shapes. Here, we present a novel 3D molecular description, namely harmonic pharma chemistry coefficient (HPCC), combining a ligand-centric pharmacophoric description projected onto a spherical harmonic based shape of a ligand. The performance of HPCC was evaluated by comparison to the standard ROCS software in a ligand-based virtual screening (VS) approach using the publicly available directory of useful decoys (DUD) data set comprising over 100,000 compounds distributed across 40 protein targets. Our results were analyzed using commonly reported statistics such as the area under the curve (AUC) and normalized sum of logarithms of ranks (NSLR) metrics. Overall, our HPCC 3D method is globally as efficient as the state-of-the-art ROCS software in terms of enrichment and slightly better for more than half of the DUD targets. Since it is largely admitted that VS results depend strongly on the nature of the protein families, we believe that the present HPCC solution is of interest over the current ligand-based VS methods. PMID:23467019

  11. Shape analysis of hypertrophic and hypertensive heart disease using MRI-based 3D surface models of left ventricular geometry.

    PubMed

    Ardekani, Siamak; Jain, Saurabh; Sanzi, Alianna; Corona-Villalobos, Celia P; Abraham, Theodore P; Abraham, M Roselle; Zimmerman, Stefan L; Wu, Katherine C; Winslow, Raimond L; Miller, Michael I; Younes, Laurent

    2016-04-01

    The focus of this study was to develop advanced mathematical tools to construct high-resolution 3D models of left-ventricular (LV) geometry to evaluate focal geometric differences between patients with hypertrophic cardiomyopathy (HCM) and hypertensive heart disease (HHD) using cardiac magnetic resonance (MR) cross-sectional images. A limiting factor in 3D analysis of cardiac MR cross-sections is the low out-of-plane resolution of the acquired images. To overcome this problem, we have developed a mathematical framework to construct a population-based high-resolution 3D LV triangulated surface (template) in which an iterative matching algorithm maps a surface mesh of a normal heart to a set of cross-sectional contours that were extracted from short-axis cine cardiac MR images of patients who were diagnosed with either HCM or HHD. A statistical analysis was conducted on deformations that were estimated at each surface node to identify shape differences at end-diastole (ED), end-systole (ES), and motion-related shape variation from ED to ES. Some significant shape difference in radial thickness was detected at ES. Differences of LV 3D surface geometry were identified focally on the basal anterior septum wall. Further research is needed to relate these findings to the HCM morphological substrate and to design a classifier to discriminate among different etiologies of LV hypertrophy. PMID:26766206

  12. A general approach for DC apparent resistivity evaluation on arbitrarily shaped 3D structures

    NASA Astrophysics Data System (ADS)

    Marescot, Laurent; Rigobert, Stéphane; Palma Lopes, Sérgio; Lagabrielle, Richard; Chapellier, Dominique

    2006-09-01

    This paper presents a general and comprehensive way to evaluate the geometric factors used for the computation of apparent resistivities in the context of DC resistivity mapping and non-destructive investigations, in laboratory or in the field. This technique enables one to consider 3-dimensional objects with arbitrary shape. The expression of the geometric factor results from the early definition of apparent resistivitiy. It is expressed as the ratio of the resistances obtained from measurements to the resistances induced in the medium with unitary resistivity considering the same object geometry and electrode set-up. In this work, a finite element code is used for the computation of the geometric factor. In this code, the electrodes do not need to be located on the nodes of the mesh. This option makes the finite element mesh generation task easier. A first synthetical example illustrates how the present approach could be applied to apparent resistivity mapping in an environment with a complex underground topography. A second example, based on real data in a water tank, illustrates the simulation of a resistivity survey on a structure with finite extent, e.g. a laboratory sample. In both examples, topographic artefacts and effects of material sample shapes are successfully taken into account and reliable apparent resistivity descriptions of the structures are obtained. The effectiveness of the method for the detection of heterogeneities in apparent resistivity maps is highlighted.

  13. Dynamic shape modeling of the mitral valve from real-time 3D ultrasound images using continuous medial representation

    NASA Astrophysics Data System (ADS)

    Pouch, Alison M.; Yushkevich, Paul A.; Jackson, Benjamin M.; Gorman, Joseph H., III; Gorman, Robert C.; Sehgal, Chandra M.

    2012-03-01

    Purpose: Patient-specific shape analysis of the mitral valve from real-time 3D ultrasound (rt-3DUS) has broad application to the assessment and surgical treatment of mitral valve disease. Our goal is to demonstrate that continuous medial representation (cm-rep) is an accurate valve shape representation that can be used for statistical shape modeling over the cardiac cycle from rt-3DUS images. Methods: Transesophageal rt-3DUS data acquired from 15 subjects with a range of mitral valve pathology were analyzed. User-initialized segmentation with level sets and symmetric diffeomorphic normalization delineated the mitral leaflets at each time point in the rt-3DUS data series. A deformable cm-rep was fitted to each segmented image of the mitral leaflets in the time series, producing a 4D parametric representation of valve shape in a single cardiac cycle. Model fitting accuracy was evaluated by the Dice overlap, and shape interpolation and principal component analysis (PCA) of 4D valve shape were performed. Results: Of the 289 3D images analyzed, the average Dice overlap between each fitted cm-rep and its target segmentation was 0.880+/-0.018 (max=0.912, min=0.819). The results of PCA represented variability in valve morphology and localized leaflet thickness across subjects. Conclusion: Deformable medial modeling accurately captures valve geometry in rt-3DUS images over the entire cardiac cycle and enables statistical shape analysis of the mitral valve.

  14. Multi-shape memory polymers achieved by the spatio-assembly of 3D printable thermoplastic building blocks.

    PubMed

    Li, Hongze; Gao, Xiang; Luo, Yingwu

    2016-04-01

    Multi-shape memory polymers were prepared by the macroscale spatio-assembly of building blocks in this work. The building blocks were methyl acrylate-co-styrene (MA-co-St) copolymers, which have the St-block-(St-random-MA)-block-St tri-block chain sequence. This design ensures that their transition temperatures can be adjusted over a wide range by varying the composition of the middle block. The two St blocks at the chain ends can generate a crosslink network in the final device to achieve strong bonding force between building blocks and the shape memory capacity. Due to their thermoplastic properties, 3D printing was employed for the spatio-assembly to build devices. This method is capable of introducing many transition phases into one device and preparing complicated shapes via 3D printing. The device can perform a complex action via a series of shape changes. Besides, this method can avoid the difficult programing of a series of temporary shapes. The control of intermediate temporary shapes was realized via programing the shapes and locations of building blocks in the final device. PMID:26924759

  15. Evaluation of trapezoidal-shaped 3-D plates for internal fixation of mandibular subcondylar fractures in adults

    PubMed Central

    Chaudhary, Manoj; Pant, Harshvardhan; Singh, Manpreet; Vashistha, Arpit; Kaur, Gagandeep

    2015-01-01

    Aims The purpose of this study is to evaluate the clinical results and to assess the efficacy, stability, and rigidity of trapezoidal 3-D plates for osteosynthesis in adult mandibular subcondylar fracture patients. Methods This study included 15 cases of trauma having mandibular subcondylar fractures, in which open reduction and internal fixation are indicated. After selecting patient according to the inclusion criteria, all patients underwent open reduction and rigid fixation. Fracture was then stabilized using 4 hole, 2.0 mm trapezoidal-shaped 3-D titanium plates using retromandibular incision. Postoperative clinical examination was carried out on 3rd day; 1st, 2nd, and 4th weeks; and 3rd and 6th months. Results The results of this study suggest that the fixation of mandibular subcondylar fracture with trapezoidal-shaped 3-D plates provides three-dimensional stability and carries low morbidity. Conclusion Patients with gross displacement of condylar fragment, major reduction in posterior facial height, and deranged occlusion can be successfully managed by open reduction of condylar fracture and its fixation using 3-D plates. PMID:26587378

  16. Generation and Comparison of Tls and SFM Based 3d Models of Solid Shapes in Hydromechanic Research

    NASA Astrophysics Data System (ADS)

    Zhang, R.; Schneider, D.; Strauß, B.

    2016-06-01

    The aim of a current study at the Institute of Hydraulic Engineering and Technical Hydromechanics at TU Dresden is to develop a new injection method for quick and economic sealing of dikes or dike bodies, based on a new synthetic material. To validate the technique, an artificial part of a sand dike was built in an experimental hall. The synthetic material was injected, which afterwards spreads in the inside of the dike. After the material was fully solidified, the surrounding sand was removed with an excavator. In this paper, two methods, which applied terrestrial laser scanning (TLS) and structure from motion (SfM) respectively, for the acquisition of a 3D point cloud of the remaining shapes are described and compared. Combining with advanced software packages, a triangulated 3D model was generated and subsequently the volume of vertical sections of the shape were calculated. As the calculation of the volume revealed differences between the TLS and the SfM 3D model, a thorough qualitative comparison of the two models will be presented as well as a detailed accuracy assessment. The main influence of the accuracy is caused by generalisation in case of gaps due to occlusions in the 3D point cloud. Therefore, improvements for the data acquisition with TLS and SfM for such kind of objects are suggested in the paper.

  17. Statistical shape analysis using 3D Poisson equation-A quantitatively validated approach.

    PubMed

    Gao, Yi; Bouix, Sylvain

    2016-05-01

    Statistical shape analysis has been an important area of research with applications in biology, anatomy, neuroscience, agriculture, paleontology, etc. Unfortunately, the proposed methods are rarely quantitatively evaluated, and as shown in recent studies, when they are evaluated, significant discrepancies exist in their outputs. In this work, we concentrate on the problem of finding the consistent location of deformation between two population of shapes. We propose a new shape analysis algorithm along with a framework to perform a quantitative evaluation of its performance. Specifically, the algorithm constructs a Signed Poisson Map (SPoM) by solving two Poisson equations on the volumetric shapes of arbitrary topology, and statistical analysis is then carried out on the SPoMs. The method is quantitatively evaluated on synthetic shapes and applied on real shape data sets in brain structures. PMID:26874288

  18. Shaped 3D Singular Spectrum Analysis for Quantifying Gene Expression, with Application to the Early Zebrafish Embryo

    PubMed Central

    Shlemov, Alex; Golyandina, Nina; Holloway, David; Spirov, Alexander

    2015-01-01

    Recent progress in microscopy technologies, biological markers, and automated processing methods is making possible the development of gene expression atlases at cellular-level resolution over whole embryos. Raw data on gene expression is usually very noisy. This noise comes from both experimental (technical/methodological) and true biological sources (from stochastic biochemical processes). In addition, the cells or nuclei being imaged are irregularly arranged in 3D space. This makes the processing, extraction, and study of expression signals and intrinsic biological noise a serious challenge for 3D data, requiring new computational approaches. Here, we present a new approach for studying gene expression in nuclei located in a thick layer around a spherical surface. The method includes depth equalization on the sphere, flattening, interpolation to a regular grid, pattern extraction by Shaped 3D singular spectrum analysis (SSA), and interpolation back to original nuclear positions. The approach is demonstrated on several examples of gene expression in the zebrafish egg (a model system in vertebrate development). The method is tested on several different data geometries (e.g., nuclear positions) and different forms of gene expression patterns. Fully 3D datasets for developmental gene expression are becoming increasingly available; we discuss the prospects of applying 3D-SSA to data processing and analysis in this growing field. PMID:26495320

  19. Graph-regularized 3D shape reconstruction from highly anisotropic and noisy images

    PubMed Central

    Heinrich, Stephanie; Drewe, Philipp; Lou, Xinghua; Umrania, Shefali; Rätsch, Gunnar

    2014-01-01

    Analysis of microscopy images can provide insight into many biological processes. One particularly challenging problem is cellular nuclear segmentation in highly anisotropic and noisy 3D image data. Manually localizing and segmenting each and every cellular nucleus is very time-consuming, which remains a bottleneck in large-scale biological experiments. In this work, we present a tool for automated segmentation of cellular nuclei from 3D fluorescent microscopic data. Our tool is based on state-of-the-art image processing and machine learning techniques and provides a user-friendly graphical user interface. We show that our tool is as accurate as manual annotation and greatly reduces the time for the registration. PMID:25866587

  20. Construction of a neuroanatomical shape complex atlas from 3D MRI brain structures.

    PubMed

    Chen, Ting; Rangarajan, Anand; Eisenschenk, Stephan J; Vemuri, Baba C

    2012-04-15

    Brain atlas construction has attracted significant attention lately in the neuroimaging community due to its application to the characterization of neuroanatomical shape abnormalities associated with various neurodegenerative diseases or neuropsychiatric disorders. Existing shape atlas construction techniques usually focus on the analysis of a single anatomical structure in which the important inter-structural information is lost. This paper proposes a novel technique for constructing a neuroanatomical shape complex atlas based on an information geometry framework. A shape complex is a collection of neighboring shapes - for example, the thalamus, amygdala and the hippocampus circuit - which may exhibit changes in shape across multiple structures during the progression of a disease. In this paper, we represent the boundaries of the entire shape complex using the zero level set of a distance transform function S(x). We then re-derive the relationship between the stationary state wave function ψ(x) of the Schrödinger equation [formula in text] and the eikonal equation [formula in text] satisfied by any distance function. This leads to a one-to-one map (up to scale) between ψ(x) and S(x) via an explicit relationship. We further exploit this relationship by mapping ψ(x) to a unit hypersphere whose Riemannian structure is fully known, thus effectively turn ψ(x) into the square-root of a probability density function. This allows us to make comparisons - using elegant, closed-form analytic expressions - between shape complexes represented as square-root densities. A shape complex atlas is constructed by computing the Karcher mean ψ¯(x) in the space of square-root densities and then inversely mapping it back to the space of distance transforms in order to realize the atlas shape. We demonstrate the shape complex atlas computation technique via a set of experiments on a population of brain MRI scans including controls and epilepsy patients with either right anterior

  1. 3D video-based deformation measurement of the pelvis bone under dynamic cyclic loading

    PubMed Central

    2011-01-01

    Background Dynamic three-dimensional (3D) deformation of the pelvic bones is a crucial factor in the successful design and longevity of complex orthopaedic oncological implants. The current solutions are often not very promising for the patient; thus it would be interesting to measure the dynamic 3D-deformation of the whole pelvic bone in order to get a more realistic dataset for a better implant design. Therefore we hypothesis if it would be possible to combine a material testing machine with a 3D video motion capturing system, used in clinical gait analysis, to measure the sub millimetre deformation of a whole pelvis specimen. Method A pelvis specimen was placed in a standing position on a material testing machine. Passive reflective markers, traceable by the 3D video motion capturing system, were fixed to the bony surface of the pelvis specimen. While applying a dynamic sinusoidal load the 3D-movement of the markers was recorded by the cameras and afterwards the 3D-deformation of the pelvis specimen was computed. The accuracy of the 3D-movement of the markers was verified with 3D-displacement curve with a step function using a manual driven 3D micro-motion-stage. Results The resulting accuracy of the measurement system depended on the number of cameras tracking a marker. The noise level for a marker seen by two cameras was during the stationary phase of the calibration procedure ± 0.036 mm, and ± 0.022 mm if tracked by 6 cameras. The detectable 3D-movement performed by the 3D-micro-motion-stage was smaller than the noise level of the 3D-video motion capturing system. Therefore the limiting factor of the setup was the noise level, which resulted in a measurement accuracy for the dynamic test setup of ± 0.036 mm. Conclusion This 3D test setup opens new possibilities in dynamic testing of wide range materials, like anatomical specimens, biomaterials, and its combinations. The resulting 3D-deformation dataset can be used for a better estimation of material

  2. Validation of 3-D Ice Accretion Measurement Methodology for Experimental Aerodynamic Simulation

    NASA Technical Reports Server (NTRS)

    Broeren, Andy P.; Addy, Harold E., Jr.; Lee, Sam; Monastero, Marianne C.

    2014-01-01

    Determining the adverse aerodynamic effects due to ice accretion often relies on dry-air wind-tunnel testing of artificial, or simulated, ice shapes. Recent developments in ice accretion documentation methods have yielded a laser-scanning capability that can measure highly three-dimensional features of ice accreted in icing wind tunnels. The objective of this paper was to evaluate the aerodynamic accuracy of ice-accretion simulations generated from laser-scan data. Ice-accretion tests were conducted in the NASA Icing Research Tunnel using an 18-inch chord, 2-D straight wing with NACA 23012 airfoil section. For six ice accretion cases, a 3-D laser scan was performed to document the ice geometry prior to the molding process. Aerodynamic performance testing was conducted at the University of Illinois low-speed wind tunnel at a Reynolds number of 1.8 x 10(exp 6) and a Mach number of 0.18 with an 18-inch chord NACA 23012 airfoil model that was designed to accommodate the artificial ice shapes. The ice-accretion molds were used to fabricate one set of artificial ice shapes from polyurethane castings. The laser-scan data were used to fabricate another set of artificial ice shapes using rapid prototype manufacturing such as stereolithography. The iced-airfoil results with both sets of artificial ice shapes were compared to evaluate the aerodynamic simulation accuracy of the laser-scan data. For four of the six ice-accretion cases, there was excellent agreement in the iced-airfoil aerodynamic performance between the casting and laser-scan based simulations. For example, typical differences in iced-airfoil maximum lift coefficient were less than 3% with corresponding differences in stall angle of approximately one degree or less. The aerodynamic simulation accuracy reported in this paper has demonstrated the combined accuracy of the laser-scan and rapid-prototype manufacturing approach to simulating ice accretion for a NACA 23012 airfoil. For several of the ice

  3. A theoretical and experimental study on no-guide light pen type 3D-coordinate measurement system

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaofang; Yu, Xin; Jiang, Chengzhi; Wang, Baoguang

    2003-04-01

    A novel no-guide light pen type 3D-coordinate measurement system with three sets of position sensitive devices (PSDs) to realize intersection converge imaging is introduced. It is called as the light pen type measurement system, because the measuring head is shaped as a pen with several light sources on it. The structure design, measurement principle and experimental results are presented. The theoretical analysis and experimental results prove that this system has advanced features of simple structure, high automation, and high accuracy, and can be used in the measurement fields of mechanical manufacture, robot, auto, aviation and medicine effectively.

  4. Compact Optical Fiber 3D Shape Sensor Based on a Pair of Orthogonal Tilted Fiber Bragg Gratings.

    PubMed

    Feng, Dingyi; Zhou, Wenjun; Qiao, Xueguang; Albert, Jacques

    2015-01-01

    In this work, a compact fiber-optic 3D shape sensor consisting of two serially connected 2° tilted fiber Bragg gratings (TFBGs) is proposed, where the orientations of the grating planes of the two TFBGs are orthogonal. The measurement of the reflective transmission spectrum from the pair of TFBGs was implemented by Fresnel reflection of the cleaved fiber end. The two groups of cladding mode resonances in the reflection spectrum respond differentially to bending, which allows for the unique determination of the magnitude and orientation of the bend plane (i.e. with a ± 180 degree uncertainty). Bending responses ranging from -0.33 to + 0.21 dB/m(-1) (depending on orientation) are experimentally demonstrated with bending from 0 to 3.03 m(-1). In the third (axial) direction, the strain is obtained directly by the shift of the TFBG Bragg wavelengths with a sensitivity of 1.06 pm/με. PMID:26617191

  5. Compact Optical Fiber 3D Shape Sensor Based on a Pair of Orthogonal Tilted Fiber Bragg Gratings

    PubMed Central

    Feng, Dingyi; Zhou, Wenjun; Qiao, Xueguang; Albert, Jacques

    2015-01-01

    In this work, a compact fiber-optic 3D shape sensor consisting of two serially connected 2° tilted fiber Bragg gratings (TFBGs) is proposed, where the orientations of the grating planes of the two TFBGs are orthogonal. The measurement of the reflective transmission spectrum from the pair of TFBGs was implemented by Fresnel reflection of the cleaved fiber end. The two groups of cladding mode resonances in the reflection spectrum respond differentially to bending, which allows for the unique determination of the magnitude and orientation of the bend plane (i.e. with a ± 180 degree uncertainty). Bending responses ranging from −0.33 to + 0.21 dB/m−1 (depending on orientation) are experimentally demonstrated with bending from 0 to 3.03 m−1. In the third (axial) direction, the strain is obtained directly by the shift of the TFBG Bragg wavelengths with a sensitivity of 1.06 pm/με. PMID:26617191

  6. Estimation of aortic valve leaflets from 3D CT images using local shape dictionaries and linear coding

    NASA Astrophysics Data System (ADS)

    Liang, Liang; Martin, Caitlin; Wang, Qian; Sun, Wei; Duncan, James

    2016-03-01

    Aortic valve (AV) disease is a significant cause of morbidity and mortality. The preferred treatment modality for severe AV disease is surgical resection and replacement of the native valve with either a mechanical or tissue prosthetic. In order to develop effective and long-lasting treatment methods, computational analyses, e.g., structural finite element (FE) and computational fluid dynamic simulations, are very effective for studying valve biomechanics. These computational analyses are based on mesh models of the aortic valve, which are usually constructed from 3D CT images though many hours of manual annotation, and therefore an automatic valve shape reconstruction method is desired. In this paper, we present a method for estimating the aortic valve shape from 3D cardiac CT images, which is represented by triangle meshes. We propose a pipeline for aortic valve shape estimation which includes novel algorithms for building local shape dictionaries and for building landmark detectors and curve detectors using local shape dictionaries. The method is evaluated on real patient image dataset using a leave-one-out approach and achieves an average accuracy of 0.69 mm. The work will facilitate automatic patient-specific computational modeling of the aortic valve.

  7. Morphogenesis and mechanostabilization of complex natural and 3D printed shapes

    PubMed Central

    Tiwary, Chandra Sekhar; Kishore, Sharan; Sarkar, Suman; Mahapatra, Debiprosad Roy; Ajayan, Pulickel M.; Chattopadhyay, Kamanio

    2015-01-01

    The natural selection and the evolutionary optimization of complex shapes in nature are closely related to their functions. Mechanostabilization of shape of biological structure via morphogenesis has several beautiful examples. With the help of simple mechanics-based modeling and experiments, we show an important causality between natural shape selection as evolutionary outcome and the mechanostabilization of seashells. The effect of biological growth on the mechanostabilization process is identified with examples of two natural shapes of seashells, one having a diametrically converging localization of stresses and the other having a helicoidally concentric localization of stresses. We demonstrate how the evolved shape enables predictable protection of soft body parts of the species. The effect of bioavailability of natural material is found to be a secondary factor compared to shape selectivity, where material microstructure only acts as a constraint to evolutionary optimization. This is confirmed by comparing the mechanostabilization behavior of three-dimensionally printed synthetic polymer structural shapes with that of natural seashells consisting of ceramic and protein. This study also highlights interesting possibilities in achieving a new design of structures made of ordinary materials which have bio-inspired optimization objectives. PMID:26601170

  8. Construction of Neuroanatomical Shape Complex Atlas from 3D Brain MRI

    PubMed Central

    Chen, Ting; Rangarajan, Anand; Eisenschenk, Stephan J.; Vemuri, Baba C.

    2010-01-01

    This paper proposes a novel technique for constructing a neuroanatomical shape complex atlas using an information geometry framework. A shape complex is a collection of shapes in a local neighborhood. We represent the boundary of the entire shape complex using the zero level set of a distance function S(x). The spatial relations between the different anatomical structures constituting the shape complex are captured via the distance transform. We then leverage the well known relationship between the stationary state wave function ψ(x) of the Schrödinger equation −ħ2∇2ψ + ψ = 0 and the eikonal equation ‖∇S‖ = 1 satisfied by any distance function S(x). This leads to a one-to-one map between ψ(x) and S(x) and allows for recovery of S(x) from ψ(x) through an explicit mathematical relationship. Since the wave function can be regarded as a square-root density function, we are able to exploit this connection and convert shape complex distance transforms into probability density functions. Furthermore, square-root density functions can be seen as points on a unit hypersphere whose Riemannian structure is fully known. A shape complex atlas is constructed by first computing the Karcher mean ψ̄(x) of the wave functions, followed by an inverse mapping of the estimated mean back to the space of distance transforms in order to realize the atlas. We demonstrate the shape complex atlas computation via a set of experiments on a population of brain MRI scans. We also present modes of variation from the computed atlas for the control population to demonstrate the shape complex variability. PMID:20879384

  9. Construction of neuroanatomical shape complex atlas from 3D brain MRI.

    PubMed

    Chen, Ting; Rangarajan, Anand; Eisenschenk, Stephan J; Vemuri, Baba C

    2010-01-01

    This paper proposes a novel technique for constructing a neuroanatomical shape complex atlas using an information geometry framework. A shape complex is a collection of shapes in a local neighborhood. We represent the boundary of the entire shape complex using the zero level set of a distance function S(x). The spatial relations between the different anatomical structures constituting the shape complex are captured via the distance transform. We then leverage the well known relationship between the stationary state wave function psi(x) of the Schrödinger equation -h2nabla2 psi + psi = 0 and the eikonal equation //nablaS// = 1 satisfied by any distance function S(x). This leads to a one-to-one map between psi(x) and S(x) and allows for recovery of S(x) from psi(x) through an explicit mathematical relationship. Since the wave function can be regarded as a square-root density function, we are able to exploit this connection and convert shape complex distance transforms into probability density functions. Furthermore, square-root density functions can be seen as points on a unit hypersphere whose Riemannian structure is fully known. A shape complex atlas is constructed by first computing the Karcher mean psi(x) of the wave functions, followed by an inverse mapping of the estimated mean back to the space of distance transforms in order to realize the atlas. We demonstrate the shape complex atlas computation via a set of experiments on a population of brain MRI scans. We also present modes of variation from the computed atlas for the control population to demonstrate the shape complex variability. PMID:20879384

  10. ShapeShop: Free-Form 3D Design with Implicit Solid Modeling

    NASA Astrophysics Data System (ADS)

    Schmidt, Ryan; Wyvill, Brian

    A technique is described for inflating 2D contours into rounded three-dimensional implicit volumes. Sketch-based modeling operations are defined that combine these basic shapes using standard blending and CSG operators. Since the underlying volume hierarchy is by definition a construction history, individual sketched components can be non-linearly edited and removed. For example, holes can be interactively dragged through a shape. ShapeShop also provides 2D drawing assistance using a new curve-sketching system based on variational contours. A wide range of models can be sketched with ShapeShop, from cartoon-like characters to detailed mechanical parts. Examples are shown which demonstrate significantly higher model complexity than existing systems.

  11. 3D Segmentation of Rodent Brain Structures Using Hierarchical Shape Priors and Deformable Models

    PubMed Central

    Zhang, Shaoting; Huang, Junzhou; Uzunbas, Mustafa; Shen, Tian; Delis, Foteini; Huang, Xiaolei; Volkow, Nora; Thanos, Panayotis; Metaxas, Dimitris N.

    2016-01-01

    In this paper, we propose a method to segment multiple rodent brain structures simultaneously. This method combines deformable models and hierarchical shape priors within one framework. The deformation module employs both gradient and appearance information to generate image forces to deform the shape. The shape prior module uses Principal Component Analysis to hierarchically model the multiple structures at both global and local levels. At the global level, the statistics of relative positions among different structures are modeled. At the local level, the shape statistics within each structure is learned from training samples. Our segmentation method adaptively employs both priors to constrain the intermediate deformation result. This prior constraint improves the robustness of the model and benefits the segmentation accuracy. Another merit of our prior module is that the size of the training data can be small, because the shape prior module models each structure individually and combines them using global statistics. This scheme can preserve shape details better than directly applying PCA on all structures. We use this method to segment rodent brain structures, such as the cerebellum, the left and right striatum, and the left and right hippocampus. The experiments show that our method works effectively and this hierarchical prior improves the segmentation performance. PMID:22003750

  12. 3D segmentation of rodent brain structures using hierarchical shape priors and deformable models.

    PubMed

    Zhang, Shaoting; Huang, Junzhou; Uzunbas, Mustafa; Shen, Tian; Delis, Foteini; Huang, Xiaolei; Volkow, Nora; Thanos, Panayotis; Metaxas, Dimitris N

    2011-01-01

    In this paper, we propose a method to segment multiple rodent brain structures simultaneously. This method combines deformable models and hierarchical shape priors within one framework. The deformation module employs both gradient and appearance information to generate image forces to deform the shape. The shape prior module uses Principal Component Analysis to hierarchically model the multiple structures at both global and local levels. At the global level, the statistics of relative positions among different structures are modeled. At the local level, the shape statistics within each structure is learned from training samples. Our segmentation method adaptively employs both priors to constrain the intermediate deformation result. This prior constraint improves the robustness of the model and benefits the segmentation accuracy. Another merit of our prior module is that the size of the training data can be small, because the shape prior module models each structure individually and combines them using global statistics. This scheme can preserve shape details better than directly applying PCA on all structures. We use this method to segment rodent brain structures, such as the cerebellum, the left and right striatum, and the left and right hippocampus. The experiments show that our method works effectively and this hierarchical prior improves the segmentation performance. PMID:22003750

  13. 3D Shape and Structure of the Homunculus of eta Carinae

    NASA Astrophysics Data System (ADS)

    Currie, D. G.; Christou, J.; Tyler, D.; Jefferies, S.; Le Mignant, D.; Bonaccini, D.

    2000-12-01

    The three-dimensional shape of the Homunculus of eta Carinae, as well as the detailed features of the SouthEast Lobe have been observed using the ADONIS system on the ESO 3.6 meter telescope at La Silla. To measure the normally invisible back wall of the Homunculus, we have observed in the infrared (to reduce the opacity of the front wall) and used the Fabry-Perot Interferometer (to distinguish between the Doppler shifts of the light reflected from the back wall and the brighter light reflected from the front wall). This analysis confirms the Double-Flask model and the orientation of the symmetry axis obtained from the previous analysis of the front wall emission and the assumption of rotational symmetry (Currie et. al. 1995, Currie et. al. 1996, Dowling 1996). To evaluate the fine detail of the turbulent motions in the front wall of the SouthEast Lobe, we use broad band observations in the H and K bands. This will be compared to the similar features seen in the shorter wavelengths (at the same resolution) by the WFPC. In the infrared, we see more detail of the shear behavior already seen at the visible wavelengths (Dowling, 1996). To further explore these features, the results of several types of deconvolution will be considered in order to obtain the optimal resolution for the AO data, and to compare the different data processing methodologies. We wish to thank ESO for the observation time, and the 3.6 meter team for observational support. We also wish to thank the STScI and WFPC IDT team. Support for individual authors has come from ESO, the University of Maryland, AFOSR, and CfAO.

  14. Surface processes on the asteroid deduced from the external 3D shapes and surface features of Itokawa particles

    NASA Astrophysics Data System (ADS)

    Tsuchiyama, A.; Matsumoto, T.

    2015-10-01

    Particles on the surface of S-type Asteroid 25143 Itokawa were successfully recovered by the Hayabusa mission of JAXA (e.g., [1,2]). They are not only the first samples recovered from an asteroid, but also the second extraterrestrial regolith to have been sampled, the first being the Moon by Apollo and Luna missions. The analysis of tiny sample particles (20-200 μm) shows that the Itokawa surface material is consistent with LL chondrites suffered by space weathering as expected and brought an end to the origin of meteorites (e.g., [2-4]). In addition, the examination of Itokawa particles allow studies of surface processes on the asteroid because regolith particles can be regarded as an interface with the space environment, where the impacts of small objects and irradiation by the solar wind and galactic cosmic rays should have been recorded. External 3D shapes and surface features of Itokawa regolith particles were examined. Two kinds of surface modification, formation of space-weathering rims mainly by solar wind implantation and surface abrasion by grain migration, were recognized. Spectral change of the asteroid proceeded by formation of space-weathering rims and refreshment of the regolith surfaces. External 3D shapes and surface morphologies of the regolith particles can provide information about formation and evolution history of regolith particles in relation to asteroidal surface processes. 3D shapes of Itokawa regolith particles were obtained using microtomography [3]. The surface nanomiromorpholgy of Itokawa particles were also observed using FE-SEM [5]. However, the number of particles was limited and genial feature on the surface morphology has not been understood. In this study, the surface morphology of Itokawa regolith particles was systematically investigated together with their 3D structures.

  15. Label-free characterization of white blood cells by measuring 3D refractive index maps

    PubMed Central

    Yoon, Jonghee; Kim, Kyoohyun; Park, HyunJoo; Choi, Chulhee; Jang, Seongsoo; Park, YongKeun

    2015-01-01

    The characterization of white blood cells (WBCs) is crucial for blood analyses and disease diagnoses. However, current standard techniques rely on cell labeling, a process which imposes significant limitations. Here we present three-dimensional (3D) optical measurements and the label-free characterization of mouse WBCs using optical diffraction tomography. 3D refractive index (RI) tomograms of individual WBCs are constructed from multiple two-dimensional quantitative phase images of samples illuminated at various angles of incidence. Measurements of the 3D RI tomogram of WBCs enable the separation of heterogeneous populations of WBCs using quantitative morphological and biochemical information. Time-lapse tomographic measurements also provide the 3D trajectory of micrometer-sized beads ingested by WBCs. These results demonstrate that optical diffraction tomography can be a useful and versatile tool for the study of WBCs. PMID:26504637

  16. Development of 3D Image Measurement System and Stereo-matching Method, and Its Archeological Measurement

    NASA Astrophysics Data System (ADS)

    Kochi, Nobuo; Ito, Tadayuki; Kitamura, Kazuo; Kaneko, Syun'ichi

    The three dimensional measurement & modeling system with digital cameras on PC is now making progress and its need and hope is increasingly felt in terrestrial (close-range) photogrammetry for such sectors as cultural heritage preservation, architecture, civil engineering, manufacturing, measurement etc. Therefore, we have developed a system to improve the accuracy of stereo-matching, which is the very core of 3D measurement. As for stereo-matching method, in order to minimize the mismatching and to be robust in geometric distortions, occlusion, as well as brightness change, we invented Coarse-to-Fine Strategy Method by integrating OCM (Orientation Code Matching) with LSM (Least Squares Matching). Thus this system could attain the accuracy of 0.26mm, when we experimented on a mannequin. And when we actually experimented on the archeological ruins in Greece and Turkey, the accuracy was within the range of 1cm, compared with their blue-print plan. Besides, formally workers used to take at least 1.5 month for this kind of survey operation with the existing method, but now workers need only 3 or 4 days. Thus, its practicality and efficiency was confirmed. This paper demonstrates our new system of 3D measurement and stereo-matching with some concrete examples as its practical application.

  17. 3D flame topography obtained by tomographic chemiluminescence with direct comparison to planar Mie scattering measurements.

    PubMed

    Xu, Wenjiang; Wickersham, A J; Wu, Yue; He, Fan; Ma, Lin

    2015-03-20

    This work reports the measurements of 3D flame topography using tomographic chemiluminescence and its validation by direct comparison against planar Mie scattering measurements. Tomographic measurements of the 3D topography of various well-controlled laboratory flames were performed using projections measured by seven cameras, and a simultaneous Mie scattering measurement was performed to measure a 2D cross section of the 3D flame topography. The tomographic measurements were based on chemiluminescence emissions from the flame, and the Mie scattering measurements were based on micrometer-size oil droplets seeded into the flow. The flame topography derived from the 3D tomographic and the Mie scattering measurement was then directly compared. The results show that the flame topography obtained from tomographic chemiluminescence and the Mie measurement agreed qualitatively (i.e., both methods yielded the same profile of the flame fronts), but a quantitative difference on the order of millimeters was observed between these two methods. These results are expected to be useful for understanding the capabilities and limitations of the 3D tomographic and Mie scattering techniques in combustion diagnostics. PMID:25968497

  18. Classification of mathematics deficiency using shape and scale analysis of 3D brain structures

    NASA Astrophysics Data System (ADS)

    Kurtek, Sebastian; Klassen, Eric; Gore, John C.; Ding, Zhaohua; Srivastava, Anuj

    2011-03-01

    We investigate the use of a recent technique for shape analysis of brain substructures in identifying learning disabilities in third-grade children. This Riemannian technique provides a quantification of differences in shapes of parameterized surfaces, using a distance that is invariant to rigid motions and re-parameterizations. Additionally, it provides an optimal registration across surfaces for improved matching and comparisons. We utilize an efficient gradient based method to obtain the optimal re-parameterizations of surfaces. In this study we consider 20 different substructures in the human brain and correlate the differences in their shapes with abnormalities manifested in deficiency of mathematical skills in 106 subjects. The selection of these structures is motivated in part by the past links between their shapes and cognitive skills, albeit in broader contexts. We have studied the use of both individual substructures and multiple structures jointly for disease classification. Using a leave-one-out nearest neighbor classifier, we obtained a 62.3% classification rate based on the shape of the left hippocampus. The use of multiple structures resulted in an improved classification rate of 71.4%.

  19. Engineering anatomically shaped vascularized bone grafts with hASCs and 3D-printed PCL scaffolds.

    PubMed

    Temple, Joshua P; Hutton, Daphne L; Hung, Ben P; Huri, Pinar Yilgor; Cook, Colin A; Kondragunta, Renu; Jia, Xiaofeng; Grayson, Warren L

    2014-12-01

    The treatment of large craniomaxillofacial bone defects is clinically challenging due to the limited availability of transplantable autologous bone grafts and the complex geometry of the bones. The ability to regenerate new bone tissues that faithfully replicate the anatomy would revolutionize treatment options. Advances in the field of bone tissue engineering over the past few decades offer promising new treatment alternatives using biocompatible scaffold materials and autologous cells. This approach combined with recent advances in three-dimensional (3D) printing technologies may soon allow the generation of large, bioartificial bone grafts with custom, patient-specific architecture. In this study, we use a custom-built 3D printer to develop anatomically shaped polycaprolactone (PCL) scaffolds with varying internal porosities. These scaffolds are assessed for their ability to support induction of human adipose-derived stem cells (hASCs) to form vasculature and bone, two essential components of functional bone tissue. The development of functional tissues is assessed in vitro and in vivo. Finally, we demonstrate the ability to print large mandibular and maxillary bone scaffolds that replicate fine details extracted from patient's computed tomography scans. The findings of this study illustrate the capabilities and potential of 3D printed scaffolds to be used for engineering autologous, anatomically shaped, vascularized bone grafts. PMID:24510413

  20. The in-situ 3D measurement system combined with CNC machine tools

    NASA Astrophysics Data System (ADS)

    Zhao, Huijie; Jiang, Hongzhi; Li, Xudong; Sui, Shaochun; Tang, Limin; Liang, Xiaoyue; Diao, Xiaochun; Dai, Jiliang

    2013-06-01

    With the development of manufacturing industry, the in-situ 3D measurement for the machining workpieces in CNC machine tools is regarded as the new trend of efficient measurement. We introduce a 3D measurement system based on the stereovision and phase-shifting method combined with CNC machine tools, which can measure 3D profile of the machining workpieces between the key machining processes. The measurement system utilizes the method of high dynamic range fringe acquisition to solve the problem of saturation induced by specular lights reflected from shiny surfaces such as aluminum alloy workpiece or titanium alloy workpiece. We measured two workpieces of aluminum alloy on the CNC machine tools to demonstrate the effectiveness of the developed measurement system.

  1. Microwave and camera sensor fusion for the shape extraction of metallic 3D space objects

    NASA Technical Reports Server (NTRS)

    Shaw, Scott W.; Defigueiredo, Rui J. P.; Krishen, Kumar

    1989-01-01

    The vacuum of space presents special problems for optical image sensors. Metallic objects in this environment can produce intense specular reflections and deep shadows. By combining the polarized RCS with an incomplete camera image, it has become possible to better determine the shape of some simple three-dimensional objects. The radar data are used in an iterative procedure that generates successive approximations to the target shape by minimizing the error between computed scattering cross-sections and the observed radar returns. Favorable results have been obtained for simulations and experiments reconstructing plates, ellipsoids, and arbitrary surfaces.

  2. Synthesis of various 3D porous gold-based alloy nanostructures with branched shapes.

    PubMed

    Swiatkowska-Warkocka, Zaneta; Pyatenko, Alexander; Koshizaki, Naoto; Kawaguchi, Kenji

    2016-12-01

    This paper presents a facile and flexible synthesis platform for various 3D porous gold-iron nanostructures based on selective laser heating of colloidal nanoparticles and selective acid treatment. The presented approach allows to create porous gold-based nanostructures with different morphologies. In addition, for the first time, our studies indicate that various nanoarchitectures (brain-like, flower-like, cage-like, or raspberry-like structures) can be obtained by varying the experimental conditions such as size of Au and Fe3O4 nanoparticles, solvent, laser fluence, and irradiation time. We believe that these porous structures will find immediate applications in catalysis and separations, where high surface area and magnetic properties are often simultaneously required. PMID:27565959

  3. Points based reconstruction and rendering of 3D shapes from large volume dataset

    NASA Astrophysics Data System (ADS)

    Zhao, Mingchang; Tian, Jie; He, Huiguang; Li, Guangming

    2003-05-01

    In the field of medical imaging, researchers often need visualize lots of 3D datasets to get the informaiton contained in these datasets. But the huge data genreated by modern medical imaging device challenge the real time processing and rendering algorithms at all the time. Spurring by the great achievement of Points Based Rendering (PBR) in the fields of computer graphics to render very large meshes, we propose a new algorithm to use the points as basic primitive of surface reconstruction and rendering to interactively reconstruct and render very large volume dataset. By utilizing the special characteristics of medical image datasets, we obtain a fast and efficient points-based reconstruction and rendering algorithm in common PC. The experimental results show taht this algorithm is feasible and efficient.

  4. High-resolution, real-time simultaneous 3D surface geometry and temperature measurement.

    PubMed

    An, Yatong; Zhang, Song

    2016-06-27

    This paper presents a method to simultaneously measure three-dimensional (3D) surface geometry and temperature in real time. Specifically, we developed 1) a holistic approach to calibrate both a structured light system and a thermal camera under exactly the same world coordinate system even though these two sensors do not share the same wavelength; and 2) a computational framework to determine the sub-pixel corresponding temperature for each 3D point as well as discard those occluded points. Since the thermal 2D imaging and 3D visible imaging systems do not share the same spectrum of light, they can perform sensing simultaneously in real time: we developed a hardware system that can achieve real-time 3D geometry and temperature measurement at 26 Hz with 768 × 960 points per frame. PMID:27410608

  5. Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging.

    PubMed

    Barratt, Dean C; Chan, Carolyn S K; Edwards, Philip J; Penney, Graeme P; Slomczykowski, Mike; Carter, Timothy J; Hawkes, David J

    2008-06-01

    Statistical shape modelling potentially provides a powerful tool for generating patient-specific, 3D representations of bony anatomy for computer-aided orthopaedic surgery (CAOS) without the need for a preoperative CT scan. Furthermore, freehand 3D ultrasound (US) provides a non-invasive method for digitising bone surfaces in the operating theatre that enables a much greater region to be sampled compared with conventional direct-contact (i.e., pointer-based) digitisation techniques. In this paper, we describe how these approaches can be combined to simultaneously generate and register a patient-specific model of the femur and pelvis to the patient during surgery. In our implementation, a statistical deformation model (SDM) was constructed for the femur and pelvis by performing a principal component analysis on the B-spline control points that parameterise the freeform deformations required to non-rigidly register a training set of CT scans to a carefully segmented template CT scan. The segmented template bone surface, represented by a triangulated surface mesh, is instantiated and registered to a cloud of US-derived surface points using an iterative scheme in which the weights corresponding to the first five principal modes of variation of the SDM are optimised in addition to the rigid-body parameters. The accuracy of the method was evaluated using clinically realistic data obtained on three intact human cadavers (three whole pelves and six femurs). For each bone, a high-resolution CT scan and rigid-body registration transformation, calculated using bone-implanted fiducial markers, served as the gold standard bone geometry and registration transformation, respectively. After aligning the final instantiated model and CT-derived surfaces using the iterative closest point (ICP) algorithm, the average root-mean-square distance between the surfaces was 3.5mm over the whole bone and 3.7mm in the region of surgical interest. The corresponding distances after aligning the

  6. Non-rigid registration of small animal skeletons from micro-CT using 3D shape context

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Bourgeat, Pierrick; Fripp, Jurgen; Acosta Tamayo, Oscar; Gregoire, Marie Claude; Salvado, Olivier

    2009-02-01

    Small animal registration is an important step for molecular image analysis. Skeleton registration from whole-body or only partial micro Computerized Tomography (CT) image is often performed to match individual rats to atlases and templates, for example to identify organs in positron emission tomography (PET). In this paper, we extend the shape context matching technique for 3D surface registration and apply it for rat hind limb skeleton registration from CT images. Using the proposed method, after standard affine iterative closest point (ICP) registration, correspondences between the 3D points from sour and target objects were robustly found and used to deform the limb skeleton surface with thin-plate-spline (TPS). Experiments are described using phantoms and actual rat hind limb skeletons. On animals, mean square errors were decreased by the proposed registration compared to that of its initial alignment. Visually, skeletons were successfully registered even in cases of very different animal poses.

  7. 3D shape tracking of minimally invasive medical instruments using optical frequency domain reflectometry

    NASA Astrophysics Data System (ADS)

    Parent, Francois; Kanti Mandal, Koushik; Loranger, Sebastien; Watanabe Fernandes, Eric Hideki; Kashyap, Raman; Kadoury, Samuel

    2016-03-01

    We propose here a new alternative to provide real-time device tracking during minimally invasive interventions using a truly-distributed strain sensor based on optical frequency domain reflectometry (OFDR) in optical fibers. The guidance of minimally invasive medical instruments such as needles or catheters (ex. by adding a piezoelectric coating) has been the focus of extensive research in the past decades. Real-time tracking of instruments in medical interventions facilitates image guidance and helps the user to reach a pre-localized target more precisely. Image-guided systems using ultrasound imaging and shape sensors based on fiber Bragg gratings (FBG)-embedded optical fibers can provide retroactive feedback to the user in order to reach the targeted areas with even more precision. However, ultrasound imaging with electro-magnetic tracking cannot be used in the magnetic resonance imaging (MRI) suite, while shape sensors based on FBG embedded in optical fibers provides discrete values of the instrument position, which requires approximations to be made to evaluate its global shape. This is why a truly-distributed strain sensor based on OFDR could enhance the tracking accuracy. In both cases, since the strain is proportional to the radius of curvature of the fiber, a strain sensor can provide the three-dimensional shape of medical instruments by simply inserting fibers inside the devices. To faithfully follow the shape of the needle in the tracking frame, 3 fibers glued in a specific geometry are used, providing 3 degrees of freedom along the fiber. Near real-time tracking of medical instruments is thus obtained offering clear advantages for clinical monitoring in remotely controlled catheter or needle guidance. We present results demonstrating the promising aspects of this approach as well the limitations of using the OFDR technique.

  8. Determination of a new uniform thorax density representative of the living population from 3D external body shape modeling.

    PubMed

    Amabile, Celia; Choisne, Julie; Nérot, Agathe; Pillet, Hélène; Skalli, Wafa

    2016-05-01

    Body segment parameters (BSP) for each body׳s segment are needed for biomechanical analysis. To provide population-specific BSP, precise estimation of body׳s segments volume and density are needed. Widely used uniform densities, provided by cadavers׳ studies, did not consider the air present in the lungs when determining the thorax density. The purpose of this study was to propose a new uniform thorax density representative of the living population from 3D external body shape modeling. Bi-planar X-ray radiographies were acquired on 58 participants allowing 3D reconstructions of the spine, rib cage and human body shape. Three methods of computing the thorax mass were compared for 48 subjects: (1) the Dempster Uniform Density Method, currently in use for BSPs calculation, using Dempster density data, (2) the Personalized Method using full-description of the thorax based on 3D reconstruction of the rib cage and spine and (3) the Improved Uniform Density Method using a uniform thorax density resulting from the Personalized Method. For 10 participants, comparison was made between the body mass obtained from a force-plate and the body mass computed with each of the three methods. The Dempster Uniform Density Method presented a mean error of 4.8% in the total body mass compared to the force-plate vs 0.2% for the Personalized Method and 0.4% for the Improved Uniform Density Method. The adjusted thorax density found from the 3D reconstruction was 0.74g/cm(3) for men and 0.73g/cm(3) for women instead of the one provided by Dempster (0.92g/cm(3)), leading to a better estimate of the thorax mass and body mass. PMID:26976227

  9. Design and fabrication of 3D-printed anatomically shaped lumbar cage for intervertebral disc (IVD) degeneration treatment.

    PubMed

    Serra, T; Capelli, C; Toumpaniari, R; Orriss, I R; Leong, J J H; Dalgarno, K; Kalaskar, D M

    2016-01-01

    Spinal fusion is the gold standard surgical procedure for degenerative spinal conditions when conservative therapies have been unsuccessful in rehabilitation of patients. Novel strategies are required to improve biocompatibility and osseointegration of traditionally used materials for lumbar cages. Furthermore, new design and technologies are needed to bridge the gap due to the shortage of optimal implant sizes to fill the intervertebral disc defect. Within this context, additive manufacturing technology presents an excellent opportunity to fabricate ergonomic shape medical implants. The goal of this study is to design and manufacture a 3D-printed lumbar cage for lumbar interbody fusion. Optimisations of the proposed implant design and its printing parameters were achieved via in silico analysis. The final construct was characterised via scanning electron microscopy, contact angle, x-ray micro computed tomography (μCT), atomic force microscopy, and compressive test. Preliminary in vitro cell culture tests such as morphological assessment and metabolic activities were performed to access biocompatibility of 3D-printed constructs. Results of in silico analysis provided a useful platform to test preliminary cage design and to find an optimal value of filling density for 3D printing process. Surface characterisation confirmed a uniform coating of nHAp with nanoscale topography. Mechanical evaluation showed mechanical properties of final cage design similar to that of trabecular bone. Preliminary cell culture results showed promising results in terms of cell growth and activity confirming biocompatibility of constructs. Thus for the first time, design optimisation based on computational and experimental analysis combined with the 3D-printing technique for intervertebral fusion cage has been reported in a single study. 3D-printing is a promising technique for medical applications and this study paves the way for future development of customised implants in spinal

  10. Mixed-scale channel networks including Kingfisher-beak-shaped 3D microfunnels for efficient single particle entrapment.

    PubMed

    Lee, Yunjeong; Lim, Yeongjin; Shin, Heungjoo

    2016-06-01

    Reproducible research results for nanofluidics and their applications require viable fabrication technologies to produce nanochannels integrated with microchannels that can guide fluid flow and analytes into/out of the nanochannels. We present the simple fabrication of mixed-scale polydimethylsiloxane (PDMS) channel networks consisting of nanochannels and microchannels via a single molding process using a monolithic mixed-scale carbon mold. The monolithic carbon mold is fabricated by pyrolyzing a polymer mold patterned by photolithography. During pyrolysis, the polymer mold shrinks by ∼90%, which enables nanosized carbon molds to be produced without a complex nanofabrication process. Because of the good adhesion between the polymer mold and the Si substrate, non-uniform volume reduction occurs during pyrolysis resulting in the formation of curved carbon mold side walls. These curved side walls and the relatively low surface energy of the mold provide efficient demolding of the PDMS channel networks. In addition, the trigonal prismatic shape of the polymer is converted into to a Kingfisher-beak-shaped carbon structure due to the non-uniform volume reduction. The transformation of this mold architecture produces a PDMS Kingfisher-beak-shaped 3D microfunnel that connects the microchannel and the nanochannel smoothly. The smooth reduction in the cross-sectional area of the 3D microfunnels enables efficient single microparticle trapping at the nanochannel entrance; this is beneficial for studies of cell transfection. PMID:27279423

  11. Reconstruction of 3D Shapes of Opaque Cumulus Clouds from Airborne Multiangle Imaging: A Proof-of-Concept

    NASA Astrophysics Data System (ADS)

    Davis, A. B.; Bal, G.; Chen, J.

    2015-12-01

    Operational remote sensing of microphysical and optical cloud properties is invariably predicated on the assumption of plane-parallel slab geometry for the targeted cloud. The sole benefit of this often-questionable assumption about the cloud is that it leads to one-dimensional (1D) radiative transfer (RT)---a textbook, computationally tractable model. We present new results as evidence that, thanks to converging advances in 3D RT, inverse problem theory, algorithm implementation, and computer hardware, we are at the dawn of a new era in cloud remote sensing where we can finally go beyond the plane-parallel paradigm. Granted, the plane-parallel/1D RT assumption is reasonable for spatially extended stratiform cloud layers, as well as the smoothly distributed background aerosol layers. However, these 1D RT-friendly scenarios exclude cases that are critically important for climate physics. 1D RT---whence operational cloud remote sensing---fails catastrophically for cumuliform clouds that have fully 3D outer shapes and internal structures driven by shallow or deep convection. For these situations, the first order of business in a robust characterization by remote sensing is to abandon the slab geometry framework and determine the 3D geometry of the cloud, as a first step toward bone fide 3D cloud tomography. With this specific goal in mind, we deliver a proof-of-concept for an entirely new kind of remote sensing applicable to 3D clouds. It is based on highly simplified 3D RT and exploits multi-angular suites of cloud images at high spatial resolution. Airborne sensors like AirMSPI readily acquire such data. The key element of the reconstruction algorithm is a sophisticated solution of the nonlinear inverse problem via linearization of the forward model and an iteration scheme supported, where necessary, by adaptive regularization. Currently, the demo uses a 2D setting to show how either vertical profiles or horizontal slices of the cloud can be accurately reconstructed

  12. Sloped irradiation techniques in deep x-ray lithography for 3D shaping of microstructures

    NASA Astrophysics Data System (ADS)

    Feiertag, Gregor; Ehrfeld, Wolfgang; Lehr, Heinz; Schmidt, Martin

    1997-07-01

    Deep x-ray lithography (DXRL) makes use of synchrotron radiation (SR) to transfer an absorber pattern from a mask into a thick resist layer. For most applications the direction of the SR beam is perpendicular to the mask and the resist plane. Subsequent replication techniques, e.g. electroforming, moulding or hot embossing, convert the resist relief obtained after development into micromechanical, microfluidic or micro- optical elements made from metals, polymers or ceramic materials. This process sequence is well known as the LIGA technique. The normal shadow printing process is complemented and enhanced by advanced techniques, e.g. by tilting the mask and the resist with respect to the SR beam or aligned multiple exposures to produce step-like structures. In this paper a technology for the fabrication of multidirectional inclined microstructures applying multiple tilted DXRL will be presented. Instead of one exposure with the mask/substrate assembly perpendicular to the SR beam, irradiation is performed several times applying tilt and rotational angles of the mask/substrate assembly relative to the SR beam. A huge variety of 3-D structures can be obtained using this technique. Some possible applications will be discussed.

  13. Mechanical Characterization and Shape Optimization of Fascicle-Like 3D Skeletal Muscle Tissues Contracted with Electrical and Optical Stimuli.

    PubMed

    Neal, Devin; Sakar, Mahmut Selman; Bashir, Rashid; Chan, Vincent; Asada, Haruhiko Harry

    2015-06-01

    In this study, we present a quantitative approach to construct effective 3D muscle tissues through shape optimization and load impedance matching with electrical and optical stimulation. We have constructed long, thin, fascicle-like skeletal muscle tissue and optimized its form factor through mechanical characterization. A new apparatus was designed and built, which allowed us to measure force-displacement characteristics with diverse load stiffnesses. We have found that (1) there is an optimal form factor that maximizes the muscle stress, (2) the energy transmitted to the load can be maximized with matched load stiffness, and (3) optical stimulation using channelrhodopsin2 in the muscle tissue can generate a twitch force as large as its electrical counterpart for well-developed muscle tissue. Using our tissue construct method, we found that an optimal initial diameter of 500 μm outperformed tissues using 250 μm by more than 60% and tissues using 760 μm by 105%. Using optimal load stiffness, our tissues have generated 12 pJ of energy per twitch at a peak generated stress of 1.28 kPa. Additionally, the difference in optically stimulated twitch performance versus electrically stimulated is a function of how well the overall tissue performs, with average or better performing strips having less than 10% difference. The unique mechanical characterization method used is generalizable to diverse load conditions and will be used to match load impedance to muscle tissue impedance for a wide variety of applications. PMID:25714129

  14. Simulating binocular vision for no-reference 3D visual quality measurement.

    PubMed

    Zhou, Wu-Jie; Yu, Lu; Wu, Ming-Wei

    2015-09-01

    Perceptual quality measurement of three-dimensional (3D) visual signals has become a fundamental challenge in 3D imaging fields. This paper proposes a novel no-reference (NR) 3D visual quality measurement (VQM) metric that uses simulations of the primary visual cortex (V1) of binocular vision. As the major technical contribution of this study, perceptual properties of simple and complex cells are considered for NR 3D-VQM. More specifically, the metric simulates the receptive fields of simple cells (one class of V1 neurons) using Gaussian derivative functions, and the receptive fields of complex cells (the other class of V1 neurons) using disparity energy responses and binocular rivalry responses. Subsequently, various quality-aware features are extracted from the primary visual cortex; these will change in the presence of distortions. Finally, those features are mapped to the subjective quality score of the distorted 3D visual signal by using support vector regression (SVR). Experiments on two publicly available 3D databases confirm the effectiveness of our proposed metric, compared to the relevant full-reference (FR) and NR metrics. PMID:26368467

  15. GPU accelerated registration of a statistical shape model of the lumbar spine to 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Khallaghi, Siavash; Abolmaesumi, Purang; Gong, Ren Hui; Chen, Elvis; Gill, Sean; Boisvert, Jonathan; Pichora, David; Borschneck, Dan; Fichtinger, Gabor; Mousavi, Parvin

    2011-03-01

    We present a parallel implementation of a statistical shape model registration to 3D ultrasound images of the lumbar vertebrae (L2-L4). Covariance Matrix Adaptation Evolution Strategy optimization technique, along with Linear Correlation of Linear Combination similarity metric have been used, to improve the robustness and capture range of the registration approach. Instantiation and ultrasound simulation have been implemented on a graphics processing unit for a faster registration. Phantom studies show a mean target registration error of 3.2 mm, while 80% of all the cases yield target registration error of below 3.5 mm.

  16. Qualitative and quantitative comparative analyses of 3D lidar landslide displacement field measurements

    NASA Astrophysics Data System (ADS)

    Haugen, Benjamin D.

    Landslide ground surface displacements vary at all spatial scales and are an essential component of kinematic and hazards analyses. Unfortunately, survey-based displacement measurements require personnel to enter unsafe terrain and have limited spatial resolution. And while recent advancements in LiDAR technology provide the ability remotely measure 3D landslide displacements at high spatial resolution, no single method is widely accepted. A series of qualitative metrics for comparing 3D landslide displacement field measurement methods were developed. The metrics were then applied to nine existing LiDAR techniques, and the top-ranking methods --Iterative Closest Point (ICP) matching and 3D Particle Image Velocimetry (3DPIV) -- were quantitatively compared using synthetic displacement and control survey data from a slow-moving translational landslide in north-central Colorado. 3DPIV was shown to be the most accurate and reliable point cloud-based 3D landslide displacement field measurement method, and the viability of LiDAR-based techniques for measuring 3D motion on landslides was demonstrated.

  17. Materials ``alchemy'': Shape-preserving chemical transformation of micro-to-macroscopic 3-D structures

    NASA Astrophysics Data System (ADS)

    Sandhage, Kenneth H.

    2010-06-01

    The scalable fabrication of nano-structured materials with complex morphologies and tailorable chemistries remains a significant challenge. One strategy for such synthesis consists of the generation of a solid structure with a desired morphology (a “preform”), followed by reactive conversion of the preform into a new chemistry. Several gas/solid and liquid/solid reaction processes that are capable of such chemical conversion into new micro-to-nano-structured materials, while preserving the macroscopic-to-microscopic preform morphologies, are described in this overview. Such shape-preserving chemical transformation of one material into another could be considered a modern type of materials “alchemy.”

  18. A contractile and counterbalancing adhesion system controls the 3D shape of crawling cells

    PubMed Central

    Burnette, Dylan T.; Shao, Lin; Ott, Carolyn; Pasapera, Ana M.; Fischer, Robert S.; Baird, Michelle A.; Der Loughian, Christelle; Delanoe-Ayari, Helene; Paszek, Matthew J.; Davidson, Michael W.; Betzig, Eric

    2014-01-01

    How adherent and contractile systems coordinate to promote cell shape changes is unclear. Here, we define a counterbalanced adhesion/contraction model for cell shape control. Live-cell microscopy data showed a crucial role for a contractile meshwork at the top of the cell, which is composed of actin arcs and myosin IIA filaments. The contractile actin meshwork is organized like muscle sarcomeres, with repeating myosin II filaments separated by the actin bundling protein α-actinin, and is mechanically coupled to noncontractile dorsal actin fibers that run from top to bottom in the cell. When the meshwork contracts, it pulls the dorsal fibers away from the substrate. This pulling force is counterbalanced by the dorsal fibers’ attachment to focal adhesions, causing the fibers to bend downward and flattening the cell. This model is likely to be relevant for understanding how cells configure themselves to complex surfaces, protrude into tight spaces, and generate three-dimensional forces on the growth substrate under both healthy and diseased conditions. PMID:24711500

  19. A correction method of color projection fringes in 3D contour measurement

    NASA Astrophysics Data System (ADS)

    Song, Li-mei; Li, Zong-yan; Chen, Chang-man; Xi, Jiang-tao; Guo, Qing-hua; Li, Xiao-jie

    2015-07-01

    In the three-dimensional (3D) contour measurement, the phase shift profilometry (PSP) method is the most widely used one. However, the measurement speed of PSP is very low because of the multiple projections. In order to improve the measurement speed, color grating stripes are used for measurement in this paper. During the measurement, only one color sinusoidal fringe is projected on the measured object. Therefore, the measurement speed is greatly improved. Since there is coupling or interference phenomenon between the adjacent color grating stripes, a color correction method is used to improve the measurement results. A method for correcting nonlinear error of measurement system is proposed in this paper, and the sinusoidal property of acquired image after correction is better than that before correction. Experimental results show that with these correction methods, the measurement errors can be reduced. Therefore, it can support a good foundation for the high-precision 3D reconstruction.

  20. Spring Characteristics of Circular Arc Shaped 3D Micro-cantilevers Fabricated Using III-V Semiconductor Strain-driven Bending Process

    NASA Astrophysics Data System (ADS)

    Sasaki, T. K.; Iwase, H.; Wang, J.; Akabori, M.; Yamada, S.

    2011-12-01

    We have investigated the characteristics of the circular arc shaped 3D micro-cantilever. The cantilever was fabricated using strain driven self-bending process based on the epitaxial growth. The arc shape can be used as the spring element in the various micro electro- mechanical- system (MEMS) applications. In this work, we focused on the force-deflection relationships, which would give the spring constant of the arc spring. In the case of the arc spring, spring constant depends on the dimensional parameters such as width, thickness and curvature radius. From the dependence of curvature radius on width, there seems no stress relaxation in width direction (transverse to deformation direction). Moreover, the measured spring constants of the fabricated cantilevers were also larger than the estimated ones from the curvature radius. The discrepancy indicates a possibility of stiffness enhancement of the circular arc shaped cantilevers.

  1. Image based cardiac acceleration map using statistical shape and 3D+t myocardial tracking models; in-vitro study on heart phantom

    NASA Astrophysics Data System (ADS)

    Pashaei, Ali; Piella, Gemma; Planes, Xavier; Duchateau, Nicolas; de Caralt, Teresa M.; Sitges, Marta; Frangi, Alejandro F.

    2013-03-01

    It has been demonstrated that the acceleration signal has potential to monitor heart function and adaptively optimize Cardiac Resynchronization Therapy (CRT) systems. In this paper, we propose a non-invasive method for computing myocardial acceleration from 3D echocardiographic sequences. Displacement of the myocardium was estimated using a two-step approach: (1) 3D automatic segmentation of the myocardium at end-diastole using 3D Active Shape Models (ASM); (2) propagation of this segmentation along the sequence using non-rigid 3D+t image registration (temporal di eomorphic free-form-deformation, TDFFD). Acceleration was obtained locally at each point of the myocardium from local displacement. The framework has been tested on images from a realistic physical heart phantom (DHP-01, Shelley Medical Imaging Technologies, London, ON, CA) in which the displacement of some control regions was known. Good correlation has been demonstrated between the estimated displacement function from the algorithms and the phantom setup. Due to the limited temporal resolution, the acceleration signals are sparse and highly noisy. The study suggests a non-invasive technique to measure the cardiac acceleration that may be used to improve the monitoring of cardiac mechanics and optimization of CRT.

  2. Numerical time-dependent 3D simulation of flow pattern and heat distribution in an ammonothermal system with various baffle shapes

    NASA Astrophysics Data System (ADS)

    Erlekampf, J.; Seebeck, J.; Savva, P.; Meissner, E.; Friedrich, J.; Alt, N. S. A.; Schlücker, E.; Frey, L.

    2014-10-01

    A numerical analysis of an ammonothermal synthesis process for the bulk growth of nitride crystals was performed. The analysis includes the development of a thermal model for a lab-scale ammonothermal autoclave, which was validated by in situ temperature measurements and applied to tailor the temperature field inside the autoclave. Based on the results of the global thermal 2D simulations, a local 3D model was used to include convective phenomena in the analysis. Moreover, the influence of the baffle and different baffle shapes on the flow velocity was investigated. Fluctuations of the temperature as well as the flow velocities occur, indicating that 3D considerations are essential to accurately investigate the heat and mass transport in ammonothermal systems.

  3. An accurate 3D shape context based non-rigid registration method for mouse whole-body skeleton registration

    NASA Astrophysics Data System (ADS)

    Xiao, Di; Zahra, David; Bourgeat, Pierrick; Berghofer, Paula; Acosta Tamayo, Oscar; Wimberley, Catriona; Gregoire, Marie C.; Salvado, Olivier

    2011-03-01

    Small animal image registration is challenging because of its joint structure, and posture and position difference in each acquisition without a standard scan protocol. In this paper, we face the issue of mouse whole-body skeleton registration from CT images. A novel method is developed for analyzing mouse hind-limb and fore-limb postures based on geodesic path descriptor and then registering the major skeletons and fore limb skeletons initially by thin-plate spline (TPS) transform based on the obtained geodesic paths and their enhanced correspondence fields. A target landmark correction method is proposed for improving the registration accuracy of the improved 3D shape context non-rigid registration method we previously proposed. A novel non-rigid registration framework, combining the skeleton posture analysis, geodesic path based initial alignment and 3D shape context model, is proposed for mouse whole-body skeleton registration. The performance of the proposed methods and framework was tested on 12 pairs of mouse whole-body skeletons. The experimental results demonstrated the flexibility, stability and accuracy of the proposed framework for automatic mouse whole body skeleton registration.

  4. An effective 3D leapfrog scheme for electromagnetic modelling of arbitrary shaped dielectric objects using unstructured meshes

    NASA Astrophysics Data System (ADS)

    Gansen, A.; El Hachemi, M.; Belouettar, S.; Hassan, O.; Morgan, K.

    2015-12-01

    In computational electromagnetics, the advantages of the standard Yee algorithm are its simplicity and its low computational costs. However, because of the accuracy losses resulting from the staircased representation of curved interfaces, it is normally not the method of choice for modelling electromagnetic interactions with objects of arbitrary shape. For these problems, an unstructured mesh finite volume time domain method is often employed, although the scheme does not satisfy the divergence free condition at the discrete level. In this paper, we generalize the standard Yee algorithm for use on unstructured meshes and solve the problem concerning the loss of accuracy linked to staircasing, while preserving the divergence free nature of the algorithm. The scheme is implemented on high quality primal Delaunay and dual Voronoi meshes. The performance of the approach was validated in previous work by simulating the scattering of electromagnetic waves by spherical 3D PEC objects in free space. In this paper we demonstrate the performance of this scheme for penetration problems in lossy dielectrics using a new averaging technique for Delaunay and Voronoi edges at the interface. A detailed explanation of the implementation of the method, and a demonstration of the quality of the results obtained for transmittance and scattering simulations by 3D objects of arbitrary shapes, are presented.

  5. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    NASA Technical Reports Server (NTRS)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  6. Recovery of the 3-D shape of the left ventricle from echocardiographic images.

    PubMed

    Coppini, G; Poli, R; Valli, G

    1995-01-01

    A computational method is reported which allows the fully automated recovery of the three-dimensional shape of the cardiac left ventricle from a reduced set of apical echo views. Two typically ill-posed problems have been faced: 1) the detection of the left ventricle contours in each view, and 2) the integration of the detected contour points (which form a sparse and partially inconsistent data set) into a single surface representation. The authors' solution to these problems is based on a careful integration of standard computer vision algorithms with neural networks. Boundary detection comprises three steps: edge detection, edge grouping, and edge classification. The first and second steps (which are typical early-vision tasks not involving specific domain-knowledge) have been performed through fast, well-established algorithms of computer vision. The higher level task of left ventricle-edge discrimination, which involves the exploitation of specific knowledge about the left ventricle silhouette, has been performed by feedforward neural networks. Following the most recent results in the field of computer vision, the first step in solving the problem of recovering the ventricle surface has been the adoption of a physically inspired model of it. Basically, the authors have modeled the left ventricle surface as a closed, thin, elastic surface and the data as a set of radial springs acting on it. The recovery process is equivalent to the settling of the surface-plus-springs system into a stable configuration of minimum potential energy. The finite element discretization of this model leads directly to an analog neural-network implementation. The efficiency of such an implementation has been remarkably enhanced through a learning algorithm which embeds specific knowledge about the shape of the left ventricle in the network. Experiments using clinical echographic sequences are described. Four apical views (each with a different rotation of the probe) have been acquired

  7. Holographic particle velocimetry - A 3D measurement technique for vortex interactions, coherent structures and turbulence

    NASA Astrophysics Data System (ADS)

    Meng, Hui; Hussain, Fazle

    1991-10-01

    To understand the topology and dynamics of coherent structures (CS), the interactions of CS with fine-scale turbulence, and the effects of CS on entrainment, mixing and combustion, experimental tools are needed that can measure velocity (preferably vorticity) vector fields in both 3D space and time. While traditional measurement techniques are not able to serve this purpose, holographic particle velocimetry (HPV) appears to be promising. In a demonstration experiment, the instantaneous 3D velocity vector fields in some simple vortical flows have been obtained using the HPV technique. In this preliminary report, the principles of the HPV technique are illustrated and the key issues in its implementation are discussed.

  8. 3D imaging in volumetric scattering media using phase-space measurements.

    PubMed

    Liu, Hsiou-Yuan; Jonas, Eric; Tian, Lei; Zhong, Jingshan; Recht, Benjamin; Waller, Laura

    2015-06-01

    We demonstrate the use of phase-space imaging for 3D localization of multiple point sources inside scattering material. The effect of scattering is to spread angular (spatial frequency) information, which can be measured by phase space imaging. We derive a multi-slice forward model for homogenous volumetric scattering, then develop a reconstruction algorithm that exploits sparsity in order to further constrain the problem. By using 4D measurements for 3D reconstruction, the dimensionality mismatch provides significant robustness to multiple scattering, with either static or dynamic diffusers. Experimentally, our high-resolution 4D phase-space data is collected by a spectrogram setup, with results successfully recovering the 3D positions of multiple LEDs embedded in turbid scattering media. PMID:26072807

  9. Cell force measurements in 3D microfabricated environments based on compliant cantilevers.

    PubMed

    Marelli, Mattia; Gadhari, Neha; Boero, Giovanni; Chiquet, Matthias; Brugger, Jürgen

    2014-01-21

    We report the fabrication, functionalization and testing of microdevices for cell culture and cell traction force measurements in three-dimensions (3D). The devices are composed of bent cantilevers patterned with cell-adhesive spots not lying on the same plane, and thus suspending cells in 3D. The cantilevers are soft enough to undergo micrometric deflections when cells pull on them, allowing cell forces to be measured by means of optical microscopy. Since individual cantilevers are mechanically independent of each other, cell traction forces are determined directly from cantilever deflections. This proves the potential of these new devices as a tool for the quantification of cell mechanics in a system with well-defined 3D geometry and mechanical properties. PMID:24217771

  10. Quantification of perspective-induced shape change of clavicles at radiography and 3D scanning to assist human identification.

    PubMed

    Stephan, Carl N; Guyomarc'h, Pierre

    2014-03-01

    Change in perspective between antemortem and postmortem imaging sessions (radiograph to radiograph and surface scan to radiograph) may cause different 2D renderings of the same osseous element complicating comparisons for identification. In this study, clavicle shape changes due to radiographic positioning and 3D laser scanning were examined in 20 right-side specimens, as pertinent to chest radiograph comparisons. Results indicate substantial changes in clavicle form with short source-to-image receptor distance, elevation of the element from the image receptor, and movement of the element away from the center beam (10% mean square for shape). Although quantitative shape differences were small when the clavicle was in close opposition to the image receptor (3% mean square), important qualitative differences remained with large distances from the center beam (e.g., conoid tubercle presence/absence). The significance of these results for image superimposition and computer-automated-shape-based searches of radiographic libraries to find matching candidates is discussed. PMID:24313366

  11. Mixed-scale channel networks including Kingfisher-beak-shaped 3D microfunnels for efficient single particle entrapment

    NASA Astrophysics Data System (ADS)

    Lee, Yunjeong; Lim, Yeongjin; Shin, Heungjoo

    2016-06-01

    Reproducible research results for nanofluidics and their applications require viable fabrication technologies to produce nanochannels integrated with microchannels that can guide fluid flow and analytes into/out of the nanochannels. We present the simple fabrication of mixed-scale polydimethylsiloxane (PDMS) channel networks consisting of nanochannels and microchannels via a single molding process using a monolithic mixed-scale carbon mold. The monolithic carbon mold is fabricated by pyrolyzing a polymer mold patterned by photolithography. During pyrolysis, the polymer mold shrinks by ~90%, which enables nanosized carbon molds to be produced without a complex nanofabrication process. Because of the good adhesion between the polymer mold and the Si substrate, non-uniform volume reduction occurs during pyrolysis resulting in the formation of curved carbon mold side walls. These curved side walls and the relatively low surface energy of the mold provide efficient demolding of the PDMS channel networks. In addition, the trigonal prismatic shape of the polymer is converted into to a Kingfisher-beak-shaped carbon structure due to the non-uniform volume reduction. The transformation of this mold architecture produces a PDMS Kingfisher-beak-shaped 3D microfunnel that connects the microchannel and the nanochannel smoothly. The smooth reduction in the cross-sectional area of the 3D microfunnels enables efficient single microparticle trapping at the nanochannel entrance; this is beneficial for studies of cell transfection.Reproducible research results for nanofluidics and their applications require viable fabrication technologies to produce nanochannels integrated with microchannels that can guide fluid flow and analytes into/out of the nanochannels. We present the simple fabrication of mixed-scale polydimethylsiloxane (PDMS) channel networks consisting of nanochannels and microchannels via a single molding process using a monolithic mixed-scale carbon mold. The monolithic

  12. Early pregnancy placental bed and fetal vascular volume measurements using 3-D virtual reality.

    PubMed

    Reus, Averil D; Klop-van der Aa, Josine; Rifouna, Maria S; Koning, Anton H J; Exalto, Niek; van der Spek, Peter J; Steegers, Eric A P

    2014-08-01

    In this study, a new 3-D Virtual Reality (3D VR) technique for examining placental and uterine vasculature was investigated. The validity of placental bed vascular volume (PBVV) and fetal vascular volume (FVV) measurements was assessed and associations of PBVV and FVV with embryonic volume, crown-rump length, fetal birth weight and maternal parity were investigated. One hundred thirty-two patients were included in this study, and measurements were performed in 100 patients. Using V-Scope software, 100 3-D Power Doppler data sets of 100 pregnancies at 12 wk of gestation were analyzed with 3D VR in the I-Space Virtual Reality system. Volume measurements were performed with semi-automatic, pre-defined parameters. The inter-observer and intra-observer agreement was excellent with all intra-class correlation coefficients >0.93. PBVVs of multiparous women were significantly larger than the PBVVs of primiparous women (p = 0.008). In this study, no other associations were found. In conclusion, V-Scope offers a reproducible method for measuring PBVV and FVV at 12 wk of gestation, although we are unsure whether the volume measured represents the true volume of the vasculature. Maternal parity influences PBVV. PMID:24798392

  13. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    NASA Astrophysics Data System (ADS)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  14. Quick and low cost measurement of soil parameters using a Kinect 3D scanner

    NASA Astrophysics Data System (ADS)

    Hut, R.; Van De Giesen, N.; Hagenaars, R.

    2013-12-01

    Retrieval of basic soil parameters such as bulk density and soil moisture from soil samples is a costly and time-consuming activity. Although indirect methods (heat or electromagnetic probes, radar backscatter, etc) are abundant, field truth measurement of soil parameters will remain important, if only to calibrate these other methods. We present a quick, field mountable setup to make 3D scans of surfaces up to 30 x 30 cm using a Kinect 3D scanner. By making scans before and after samples are taken, parameters such as bulk density and moisture content can easily be calculated.

  15. 3D strain measurement in electronic devices using through-focal annular dark-field imaging.

    PubMed

    Kim, Suhyun; Jung, Younheum; Lee, Sungho; Jung Kim, Joong; Byun, Gwangseon; Lee, Sunyoung; Lee, Haebum

    2014-11-01

    Spherical aberration correction in high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) allows us to form an electron probe with reduced depth of field. Using through-focal HAADF imaging, we experimentally demonstrated 3D strain measurement in a strained-channel transistor. The strain field distribution in the channel region was obtained by scanning an electron beam over a plan-view specimen. Furthermore, the decrease in the strain fields toward the silicon substrate was revealed at different focal planes with a 5-nm focal step. These results demonstrate that it is possible to reconstruct the 3D strain field in electronic devices. PMID:24859824

  16. Research of aluminium alloy aerospace structure aperture measurement based on 3D digital speckle correlation method

    NASA Astrophysics Data System (ADS)

    Bai, Lu; Wang, Hongbo; Zhou, Jiangfan; Yang, Rong; Zhang, Hui

    2014-11-01

    In this paper, the aperture change of the aluminium alloy aerospace structure under real load is researched. Static experiments are carried on which is simulated the load environment of flight course. Compared with the traditional methods, through experiments results, it's proved that 3D digital speckle correlation method has good adaptability and precision on testing aperture change, and it can satisfy measurement on non-contact,real-time 3D deformation or stress concentration. The test results of new method is compared with the traditional method.

  17. Left-ventricle segmentation in real-time 3D echocardiography using a hybrid active shape model and optimal graph search approach

    NASA Astrophysics Data System (ADS)

    Zhang, Honghai; Abiose, Ademola K.; Campbell, Dwayne N.; Sonka, Milan; Martins, James B.; Wahle, Andreas

    2010-03-01

    Quantitative analysis of the left ventricular shape and motion patterns associated with left ventricular mechanical dyssynchrony (LVMD) is essential for diagnosis and treatment planning in congestive heart failure. Real-time 3D echocardiography (RT3DE) used for LVMD analysis is frequently limited by heavy speckle noise or partially incomplete data, thus a segmentation method utilizing learned global shape knowledge is beneficial. In this study, the endocardial surface of the left ventricle (LV) is segmented using a hybrid approach combining active shape model (ASM) with optimal graph search. The latter is used to achieve landmark refinement in the ASM framework. Optimal graph search translates the 3D segmentation into the detection of a minimum-cost closed set in a graph and can produce a globally optimal result. Various information-gradient, intensity distributions, and regional-property terms-are used to define the costs for the graph search. The developed method was tested on 44 RT3DE datasets acquired from 26 LVMD patients. The segmentation accuracy was assessed by surface positioning error and volume overlap measured for the whole LV as well as 16 standard LV regions. The segmentation produced very good results that were not achievable using ASM or graph search alone.

  18. Combination 3D TOP with 2D PC MRA Techique for cerebral blood flow volume measurement.

    PubMed

    Guo, G; Wu, R H; Zhang, Y P; Guan, J T; Guo, Y L; Cheng, Y; terBrugge, K; Mikulis, D J

    2006-01-01

    To demonstrate the discrepancy of cerebral blood flow volume (BFV) estimation with 2D phase-contrast (2D PC) MRA guided with 3D time-of-flight (3D TOF) MR localization by using an "internal" standard. 20 groups of the common (CCA), internal (ICA), and external (ECA) carotid arteries in 10 healthy subjects were examined with 2D PC MRA guided by 3D TOF MR angiograms. The sum BFV of the internal and external carotid arteries was then compared with the ipsilateral common carotid artery flow. An accurate technique would demonstrate no difference. The difference was therefore a measure of accuracy of the method. 3D TOF MRA localization is presented to allow the determination of a slice orientation to improve the accuracy of 2D PC MRA in estimate the BFV. By using the combined protocols, there was better correlation in BFV estimate between the sum of ICA+ECA with the ipsilateral CCA (R2=0.729, P=0.000). The inconsistency (mean +/- SD) was found to be 6.95 +/- 5.95% for estimate the BFV in ICA+ECA and ipsilateral CCA. The main inconsistency was contributed to the ECA and its branches. Guided with 3D TOF MRA localization, 2D PC MRA is more accurate in the determination of blood flow volume in the carotid arteries. PMID:17946401

  19. 3D OCT imaging in clinical settings: toward quantitative measurements of retinal structures

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Fuller, Alfred R.; Zhao, Mingtao; Wiley, David F.; Choi, Stacey S.; Bower, Bradley A.; Hamann, Bernd; Izatt, Joseph A.; Werner, John S.

    2006-02-01

    The acquisition speed of current FD-OCT (Fourier Domain - Optical Coherence Tomography) instruments allows rapid screening of three-dimensional (3D) volumes of human retinas in clinical settings. To take advantage of this ability requires software used by physicians to be capable of displaying and accessing volumetric data as well as supporting post processing in order to access important quantitative information such as thickness maps and segmented volumes. We describe our clinical FD-OCT system used to acquire 3D data from the human retina over the macula and optic nerve head. B-scans are registered to remove motion artifacts and post-processed with customized 3D visualization and analysis software. Our analysis software includes standard 3D visualization techniques along with a machine learning support vector machine (SVM) algorithm that allows a user to semi-automatically segment different retinal structures and layers. Our program makes possible measurements of the retinal layer thickness as well as volumes of structures of interest, despite the presence of noise and structural deformations associated with retinal pathology. Our software has been tested successfully in clinical settings for its efficacy in assessing 3D retinal structures in healthy as well as diseased cases. Our tool facilitates diagnosis and treatment monitoring of retinal diseases.

  20. Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions

    PubMed Central

    Park, Yong-Lae; Elayaperumal, Santhi; Daniel, Bruce; Ryu, Seok Chang; Shin, Mihye; Savall, Joan; Black, Richard J.; Moslehi, Behzad; Cutkosky, Mark R.

    2015-01-01

    We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-μm-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner. PMID:26405428

  1. Shot noise limit of the optical 3D measurement methods for smooth surfaces

    NASA Astrophysics Data System (ADS)

    Pavliček, Pavel; Pech, Miroslav

    2016-03-01

    The measurement uncertainty of optical 3D measurement methods for smooth surfaces caused by shot noise is investigated. The shot noise is a fundamental property of the quantum nature of light. If all noise sources are eliminated, the shot noise represents the ultimate limit of the measurement uncertainty. The measurement uncertainty is calculated for several simple model methods. The analysis shows that the measurement uncertainty depends on the wavelength of used light, the number of photons used for the measurement, and on a factor that is connected with the geometric arrangement of the measurement setup.

  2. How linguistic and cultural forces shape conceptions of time: English and Mandarin time in 3D.

    PubMed

    Fuhrman, Orly; McCormick, Kelly; Chen, Eva; Jiang, Heidi; Shu, Dingfang; Mao, Shuaimei; Boroditsky, Lera

    2011-01-01

    In this paper we examine how English and Mandarin speakers think about time, and we test how the patterns of thinking in the two groups relate to patterns in linguistic and cultural experience. In Mandarin, vertical spatial metaphors are used more frequently to talk about time than they are in English; English relies primarily on horizontal terms. We present results from two tasks comparing English and Mandarin speakers' temporal reasoning. The tasks measure how people spatialize time in three-dimensional space, including the sagittal (front/back), transverse (left/right), and vertical (up/down) axes. Results of Experiment 1 show that people automatically create spatial representations in the course of temporal reasoning, and these implicit spatializations differ in accordance with patterns in language, even in a non-linguistic task. Both groups showed evidence of a left-to-right representation of time, in accordance with writing direction, but only Mandarin speakers showed a vertical top-to-bottom pattern for time (congruent with vertical spatiotemporal metaphors in Mandarin). Results of Experiment 2 confirm and extend these findings, showing that bilinguals' representations of time depend on both long-term and proximal aspects of language experience. Participants who were more proficient in Mandarin were more likely to arrange time vertically (an effect of previous language experience). Further, bilinguals were more likely to arrange time vertically when they were tested in Mandarin than when they were tested in English (an effect of immediate linguistic context). PMID:21884222

  3. Effect of shape, size, and aspect ratio on nanoparticle penetration and distribution inside solid tissues using 3D spheroid models.

    PubMed

    Agarwal, Rachit; Jurney, Patrick; Raythatha, Mansi; Singh, Vikramjit; Sreenivasan, Sidlgata V; Shi, Li; Roy, Krishnendu

    2015-10-28

    Efficient penetration and uniform distribution of nanoparticles (NPs) inside solid tissues and tumors is paramount to their therapeutic and diagnostic success. While many studies have reported the effect of NP size and charge on intratissue distribution, role of shape, and aspect ratio on NP transport inside solid tissues remain unclear. Here experimental and theoretical studies are reported on how nanoscale geometry of Jet and Flash Imprint Lithography-fabricated, polyethylene-glycol-based anionic nanohydrogels affect their penetration and distribution inside 3D spheroids, a model representing the intervascular region of solid, tumor-like tissues. Unexpectedly, low aspect ratio cylindrical NPs (H/D ≈0.3; disk-like particles, 100 nm height, and 325 nm diameter) show maximal intratissue delivery (>50% increase in total cargo delivered) and more uniform penetration compared to nanorods or smaller NPs of the same shape. This is in contrast to spherical NPs where smaller NP size resulted in deeper, more uniform penetration. Our results provide fundamental new knowledge on NP transport inside solid tissues and further establish shape and aspect ratio as important design parameters in developing more efficient, better penetrating, nanocarriers for drug, or contrast-agent delivery. PMID:26376024

  4. High-speed 3D face measurement based on color speckle projection

    NASA Astrophysics Data System (ADS)

    Xue, Junpeng; Su, Xianyu; Zhang, Qican

    2015-03-01

    Nowadays, 3D face recognition has become a subject of considerable interest in the security field due to its unique advantages in domestic and international. However, acquiring color-textured 3D faces data in a fast and accurate manner is still highly challenging. In this paper, a new approach based on color speckle projection for 3D face data dynamic acquisition is proposed. Firstly, the projector-camera color crosstalk matrix that indicates how much each projector channel influences each camera channel is measured. Secondly, the reference-speckle-sets images are acquired with CCD, and then three gray sets are separated from the color sets using the crosstalk matrix and are saved. Finally, the color speckle image which is modulated by face is captured, and it is split three gray channels. We measure the 3D face using multi-sets of speckle correlation methods with color speckle image in high-speed similar as one-shot, which greatly improves the measurement accuracy and stability. The suggested approach has been implemented and the results are supported by experiments.

  5. 3D nonrigid medical image registration using a new information theoretic measure

    NASA Astrophysics Data System (ADS)

    Li, Bicao; Yang, Guanyu; Coatrieux, Jean Louis; Li, Baosheng; Shu, Huazhong

    2015-11-01

    This work presents a novel method for the nonrigid registration of medical images based on the Arimoto entropy, a generalization of the Shannon entropy. The proposed method employed the Jensen-Arimoto divergence measure as a similarity metric to measure the statistical dependence between medical images. Free-form deformations were adopted as the transformation model and the Parzen window estimation was applied to compute the probability distributions. A penalty term is incorporated into the objective function to smooth the nonrigid transformation. The goal of registration is to optimize an objective function consisting of a dissimilarity term and a penalty term, which would be minimal when two deformed images are perfectly aligned using the limited memory BFGS optimization method, and thus to get the optimal geometric transformation. To validate the performance of the proposed method, experiments on both simulated 3D brain MR images and real 3D thoracic CT data sets were designed and performed on the open source elastix package. For the simulated experiments, the registration errors of 3D brain MR images with various magnitudes of known deformations and different levels of noise were measured. For the real data tests, four data sets of 4D thoracic CT from four patients were selected to assess the registration performance of the method, including ten 3D CT images for each 4D CT data covering an entire respiration cycle. These results were compared with the normalized cross correlation and the mutual information methods and show a slight but true improvement in registration accuracy.

  6. 3D measurements of ignition processes at 20 kHz in a supersonic combustor

    NASA Astrophysics Data System (ADS)

    Ma, Lin; Lei, Qingchun; Wu, Yue; Ombrello, Timothy M.; Carter, Campbell D.

    2015-05-01

    The ignition dynamics in a Mach 2 combustor were investigated using a three-dimensional (3D) diagnostic with 20 kHz temporal resolution. The diagnostic was based on a combination of tomographic chemiluminescence and fiber-based endoscopes (FBEs). Customized FBEs were employed to capture line-of-sight integrated chemiluminescence images (termed projections) of the combustor from eight different orientations simultaneously at 20 kHz. The measured projections were then used in a tomographic algorithm to obtain 3D reconstruction of the sparks, ignition kernel, and stable flame. Processing the reconstructions frame by frame resulted in 4D measurements. Key properties were then extracted to quantify the ignition processes, including 3D volume, surface area, sphericity, and velocity of the ignition kernel. The data collected in this work revealed detailed spatiotemporal dynamics of the ignition kernel, which are not obtainable with planar diagnostics, such as its growth, movement, and development into "stable" combustion. This work also illustrates the potential for obtaining quantitative 3D measurements using tomographic techniques and the practical utility of FBEs.

  7. 3D velocity measurements in a premixed flame by tomographic PIV

    NASA Astrophysics Data System (ADS)

    Tokarev, M. P.; Sharaborin, D. K.; Lobasov, A. S.; Chikishev, L. M.; Dulin, V. M.; Markovich, D. M.

    2015-06-01

    Tomographic particle image velocimetry (PIV) has become a standard tool for 3D velocity measurements in non-reacting flows. However, the majority of the measurements in flows with combustion are limited to small resolved depth compared to the size of the field of view (typically 1 : 10). The limitations are associated with inhomogeneity of the volume illumination and the non-uniform flow seeding, the optical distortions and errors in the 3D calibration, and the unwanted flame luminosity. In the present work, the above constraints were overcome for the tomographic PIV experiment in a laminar axisymmetric premixed flame. The measurements were conducted for a 1 : 1 depth-to-size ratio using a system of eight CCD cameras and a 200 mJ pulsed laser. The results show that camera calibration based on the triangulation of the tracer particles in the non-reacting conditions provided reliable accuracy for the 3D image reconstruction in the flame. The modification of the tomographic reconstruction allowed a posteriori removal of unwanted bright objects, which were located outside of the region of interest but affected the reconstruction quality. This study reports on a novel experience for the instantaneous 3D velocimetry in laboratory-scale flames by using tomographic PIV.

  8. Validity Study of Vertebral Rotation Measurement Using 3-D Ultrasound in Adolescent Idiopathic Scoliosis.

    PubMed

    Wang, Qian; Li, Meng; Lou, Edmond H M; Chu, Winnie C W; Lam, Tsz-Ping; Cheng, Jack C Y; Wong, Man-Sang

    2016-07-01

    This study aimed to assess the validity of 3-D ultrasound measurements on the vertebral rotation of adolescent idiopathic scoliosis (AIS) under clinical settings. Thirty curves (mean Cobb angle: 21.7° ± 15.9°) from 16 patients with AIS were recruited. 3-D ultrasound and magnetic resonance imaging scans were performed at the supine position. Each of the two raters measured the apical vertebral rotation using the center of laminae (COL) method in the 3-D ultrasound images and the Aaro-Dahlborn method in the magnetic resonance images. The intra- and inter-reliability of the COL method was demonstrated by the intra-class correlation coefficient (ICC) (both [2, K] >0.9, p < 0.05). The COL method showed no significant difference (p < 0.05) compared with the Aaro-Dahlborn method. Furthermore, the agreement between these two methods was demonstrated by the Bland-Altman method, and high correlation was found (r > 0.9, p < 0.05). These results validated the proposed 3-D ultrasound method in the measurements of vertebral rotation in the patients with AIS. PMID:27083978

  9. Highly efficient full-wave electromagnetic analysis of 3-D arbitrarily shaped waveguide microwave devices using an integral equation technique

    NASA Astrophysics Data System (ADS)

    Vidal, A.; San-Blas, A. A.; Quesada-Pereira, F. D.; Pérez-Soler, J.; Gil, J.; Vicente, C.; Gimeno, B.; Boria, V. E.

    2015-07-01

    A novel technique for the full-wave analysis of 3-D complex waveguide devices is presented. This new formulation, based on the Boundary Integral-Resonant Mode Expansion (BI-RME) method, allows the rigorous full-wave electromagnetic characterization of 3-D arbitrarily shaped metallic structures making use of extremely low CPU resources (both time and memory). The unknown electric current density on the surface of the metallic elements is represented by means of Rao-Wilton-Glisson basis functions, and an algebraic procedure based on a singular value decomposition is applied to transform such functions into the classical solenoidal and nonsolenoidal basis functions needed by the original BI-RME technique. The developed tool also provides an accurate computation of the electromagnetic fields at an arbitrary observation point of the considered device, so it can be used for predicting high-power breakdown phenomena. In order to validate the accuracy and efficiency of this novel approach, several new designs of band-pass waveguides filters are presented. The obtained results (S-parameters and electromagnetic fields) are successfully compared both to experimental data and to numerical simulations provided by a commercial software based on the finite element technique. The results obtained show that the new technique is specially suitable for the efficient full-wave analysis of complex waveguide devices considering an integrated coaxial excitation, where the coaxial probes may be in contact with the metallic insets of the component.

  10. Prostate boundary segmentation from ultrasound images using 2D active shape models: optimisation and extension to 3D.

    PubMed

    Hodge, Adam C; Fenster, Aaron; Downey, Dónal B; Ladak, Hanif M

    2006-12-01

    Boundary outlining, or segmentation, of the prostate is an important task in diagnosis and treatment planning for prostate cancer. This paper describes an algorithm based on two-dimensional (2D) active shape models (ASM) for semi-automatic segmentation of the prostate boundary from ultrasound images. Optimisation of the 2D ASM for prostatic ultrasound was done first by examining ASM construction and image search parameters. Extension of the algorithm to three-dimensional (3D) segmentation was then done using rotational-based slicing. Evaluation of the 3D segmentation algorithm used distance- and volume-based error metrics to compare algorithm generated boundary outlines to gold standard (manually generated) boundary outlines. Minimum description length landmark placement for ASM construction, and specific values for constraints and image search were found to be optimal. Evaluation of the algorithm versus gold standard boundaries found an average mean absolute distance of 1.09+/-0.49 mm, an average percent absolute volume difference of 3.28+/-3.16%, and a 5x speed increase versus manual segmentation. PMID:16930764

  11. Reference Frames and 3-D Shape Perception of Pictured Objects: On Verticality and Viewpoint-From-Above

    PubMed Central

    van Doorn, Andrea J.; Wagemans, Johan

    2016-01-01

    Research on the influence of reference frames has generally focused on visual phenomena such as the oblique effect, the subjective visual vertical, the perceptual upright, and ambiguous figures. Another line of research concerns mental rotation studies in which participants had to discriminate between familiar or previously seen 2-D figures or pictures of 3-D objects and their rotated versions. In the present study, we disentangled the influence of the environmental and the viewer-centered reference frame, as classically done, by comparing the performances obtained in various picture and participant orientations. However, this time, the performance is the pictorial relief: the probed 3-D shape percept of the depicted object reconstructed from the local attitude settings of the participant. Comparisons between the pictorial reliefs based on different picture and participant orientations led to two major findings. First, in general, the pictorial reliefs were highly similar if the orientation of the depicted object was vertical with regard to the environmental or the viewer-centered reference frame. Second, a viewpoint-from-above interpretation could almost completely account for the shears occurring between the pictorial reliefs. More specifically, the shears could largely be considered as combinations of slants generated from the viewpoint-from-above, which was determined by the environmental as well as by the viewer-centered reference frame. PMID:27433329

  12. Coronates, spherical containers, bowl-shaped surfaces, porous 1D-, 2D-, 3D-metallo-coordination polymers, and metallodendrimers.

    PubMed

    Saalfrank, Rolf W; Scheurer, Andreas

    2012-01-01

    Supramolecular coordination cages and polymers bear exceptional advantages over their organic counterparts. They are available in one-pot reactions and in high yields and display physical properties that are generally inaccessible with organic species. Moreover, their weak, reversible, noncovalent bonding interactions facilitate error checking and self-correction. This review emphasizes the achievements in supramolecular coordination container as well as polymer chemistry initiated by serendipity and their materialization based on rational design. The recognition of similarities in the synthesis of different supramolecular assemblies allows prediction of potential structures in related cases. The combination of detailed symmetry considerations with the basic rules of coordination chemistry has only recently allowed for the design of rational strategies for the construction of a variety of nanosized spherical containers, bowls, 1D-, 2D-, and 3D-coordination polymers with specified size and shape. PMID:22160460

  13. Flexible Fabrication of Shape-Controlled Collagen Building Blocks for Self-Assembly of 3D Microtissues.

    PubMed

    Zhang, Xu; Meng, Zhaoxu; Ma, Jingyun; Shi, Yang; Xu, Hui; Lykkemark, Simon; Qin, Jianhua

    2015-08-12

    Creating artificial tissue-like structures that possess the functionality, specificity, and architecture of native tissues remains a big challenge. A new and straightforward strategy for generating shape-controlled collagen building blocks with a well-defined architecture is presented, which can be used for self-assembly of complex 3D microtissues. Collagen blocks with tunable geometries are controllably produced and released via a membrane-templated microdevice. The formation of functional microtissues by embedding tissue-specific cells into collagen blocks with expression of specific proteins is described. The spontaneous self-assembly of cell-laden collagen blocks into organized tissue constructs with predetermined configurations is demonstrated, which are largely driven by the synergistic effects of cell-cell and cell-matrix interactions. This new strategy would open up new avenues for the study of tissue/organ morphogenesis, and tissue engineering applications. PMID:25920010

  14. Dynamic DNA devices and assemblies formed by shape-complementary, non-base pairing 3D components

    NASA Astrophysics Data System (ADS)

    Gerling, Thomas; Wagenbauer, Klaus F.; Neuner, Andrea M.; Dietz, Hendrik

    2015-03-01

    We demonstrate that discrete three-dimensional (3D) DNA components can specifically self-assemble in solution on the basis of shape-complementarity and without base pairing. Using this principle, we produced homo- and heteromultimeric objects, including micrometer-scale one- and two-stranded filaments and lattices, as well as reconfigurable devices, including an actuator, a switchable gear, an unfoldable nanobook, and a nanorobot. These multidomain assemblies were stabilized via short-ranged nucleobase stacking bonds that compete against electrostatic repulsion between the components’ interfaces. Using imaging by electron microscopy, ensemble and single-molecule fluorescence resonance energy transfer spectroscopy, and electrophoretic mobility analysis, we show that the balance between attractive and repulsive interactions, and thus the conformation of the assemblies, may be finely controlled by global parameters such as cation concentration or temperature and by an allosteric mechanism based on strand-displacement reactions.

  15. Dynamic DNA devices and assemblies formed by shape-complementary, non-base pairing 3D components.

    PubMed

    Gerling, Thomas; Wagenbauer, Klaus F; Neuner, Andrea M; Dietz, Hendrik

    2015-03-27

    We demonstrate that discrete three-dimensional (3D) DNA components can specifically self-assemble in solution on the basis of shape-complementarity and without base pairing. Using this principle, we produced homo- and heteromultimeric objects, including micrometer-scale one- and two-stranded filaments and lattices, as well as reconfigurable devices, including an actuator, a switchable gear, an unfoldable nanobook, and a nanorobot. These multidomain assemblies were stabilized via short-ranged nucleobase stacking bonds that compete against electrostatic repulsion between the components' interfaces. Using imaging by electron microscopy, ensemble and single-molecule fluorescence resonance energy transfer spectroscopy, and electrophoretic mobility analysis, we show that the balance between attractive and repulsive interactions, and thus the conformation of the assemblies, may be finely controlled by global parameters such as cation concentration or temperature and by an allosteric mechanism based on strand-displacement reactions. PMID:25814577

  16. A fast method to measure the 3D surface of the human heart

    NASA Astrophysics Data System (ADS)

    Cao, Yiping; Su, Xianyu; Xiang, Liqun; Chen, Wenjing; Zhang, Qican

    2003-12-01

    Three-dimensional (3-D) automatic measurement of an object is widely used in many fields. In Biology and Medicine society, it can be applicable for surgery, orthopedics, viscera disease analysis and diagnosis etc. Here a new fast method to measure the 3D surface of human heart is proposed which can provide doctors a lot of information, such as the size of heart profile, the sizes of the left or right heart ventricle, and the curvature center and radius of heart ventricle, to fully analyze and diagnose pathobiology of human heart. The new fast method is optically and noncontacted and based upon the Phase Measurement Profilometry (PMP), which has higher measuring precision. A human heart specimen experiment has verified our method.

  17. High fidelity digital inline holographic method for 3D flow measurements.

    PubMed

    Toloui, Mostafa; Hong, Jiarong

    2015-10-19

    Among all the 3D optical flow diagnostic techniques, digital inline holographic particle tracking velocimetry (DIH-PTV) provides the highest spatial resolution with low cost, simple and compact optical setups. Despite these advantages, DIH-PTV suffers from major limitations including poor longitudinal resolution, human intervention (i.e. requirement for manually determined tuning parameters during tracer field reconstruction and extraction), limited tracer concentration, and expensive computations. These limitations prevent this technique from being widely used for high resolution 3D flow measurements. In this study, we present a novel holographic particle extraction method with the goal of overcoming all the major limitations of DIH-PTV. The proposed method consists of multiple steps involving 3D deconvolution, automatic signal-to-noise ratio enhancement and thresholding, and inverse iterative particle extraction. The entire method is implemented using GPU-based algorithm to increase the computational speed significantly. Validated with synthetic particle holograms, the proposed method can achieve particle extraction rate above 95% with fake particles less than 3% and maximum position error below 1.6 particle diameter for holograms with particle concentration above 3000 particles/mm3. The applicability of the proposed method for DIH-PTV has been further validated using the experiment of laminar flow in a microchannel and the synthetic tracer flow fields generated using a DNS turbulent channel flow database. Such improvements will substantially enhance the implementation of DIH-PTV for 3D flow measurements and enable the potential commercialization of this technique. PMID:26480377

  18. System crosstalk measurement of a time-sequential 3D display using ideal shutter glasses

    NASA Astrophysics Data System (ADS)

    Chen, Fu-Hao; Huang, Kuo-Chung; Lin, Lang-Chin; Chou, Yi-Heng; Lee, Kuen

    2011-03-01

    The market of stereoscopic 3D TV grows up fast recently; however, for 3D TV really taking off, the interoperability of shutter glasses (SG) to view different TV sets must be solved, so we developed a measurement method with ideal shutter glasses (ISG) to separate time-sequential stereoscopic displays and SG. For measuring the crosstalk from time-sequential stereoscopic 3D displays, the influences from SG must be eliminated. The advantages are that the sources to crosstalk are distinguished, and the interoperability of SG is broadened. Hence, this paper proposed ideal shutter glasses, whose non-ideal properties are eliminated, as a platform to evaluate the crosstalk purely from the display. In the ISG method, the illuminance of the display was measured in time domain to analyze the system crosstalk SCT of the display. In this experiment, the ISG method was used to measure SCT with a high-speed-response illuminance meter. From the time-resolved illuminance signals, the slow time response of liquid crystal leading to SCT is visualized and quantified. Furthermore, an intriguing phenomenon that SCT measured through SG increases with shortening view distance was observed, and it may arise from LC leakage of the display and shutter leakage at large view angle. Thus, we measured how LC and shutter leakage depending on view angle and verified our argument. Besides, we used the ISG method to evaluate two displays.

  19. An Approach to 3d Digital Modeling of Surfaces with Poor Texture by Range Imaging Techniques. `SHAPE from Stereo' VS. `SHAPE from Silhouette' in Digitizing Jorge Oteiza's Sculptures

    NASA Astrophysics Data System (ADS)

    García Fernández, J.; Álvaro Tordesillas, A.; Barba, S.

    2015-02-01

    Despite eminent development of digital range imaging techniques, difficulties persist in the virtualization of objects with poor radiometric information, in other words, objects consisting of homogeneous colours (totally white, black, etc.), repetitive patterns, translucence, or materials with specular reflection. This is the case for much of the Jorge Oteiza's works, particularly in the sculpture collection of the Museo Fundación Jorge Oteiza (Navarra, Spain). The present study intend to analyse and asses the performance of two digital 3D-modeling methods based on imaging techniques, facing cultural heritage in singular cases, determined by radiometric characteristics as mentioned: Shape from Silhouette and Shape from Stereo. On the other hand, the text proposes the definition of a documentation workflow and presents the results of its application in the collection of sculptures created by Oteiza.

  20. Measuring the orientation and rotation rate of 3D printed particles in turbulent flow

    NASA Astrophysics Data System (ADS)

    Voth, Greg; Marcus, Guy G.; Parsa, Shima; Kramel, Stefan; Ni, Rui; Cole, Brendan

    2014-11-01

    The orientation distribution and rotations of anisotropic particles plays a key role in many applications ranging from icy clouds to papermaking and drag reduction in pipe flow. Experimental access to time resolved orientations of anisotropic particles has not been easy to achieve. We have found that 3D printing technology can be used to fabricate a wide range of particle shapes with smallest dimension down to 300 μm. So far we have studied rods, crosses, jacks, tetrads, and helical shapes. We extract the particle orientations from stereoscopic video images using a method of least squares optimization in Euler angle space. We find that in turbulence the orientation and rotation rate of many particles can be understood using a simple picture of alignment of both the vorticity and a long axis of the particle with the Lagrangian stretching direction of the flow. This research is supported by NSF Grant DMR-1208990.

  1. Measuring the orientation and rotation rate of 3D printed particles in turbulent flow

    NASA Astrophysics Data System (ADS)

    Voth, Greg; Kramel, Stefan; Cole, Brendan

    2015-03-01

    The orientation distribution and rotations of anisotropic particles plays a key role in many applications ranging from icy clouds to papermaking and drag reduction in pipe flow. Experimental access to time resolved orientations of anisotropic particles has not been easy to achieve. We have found that 3D printing technology can be used to fabricate a wide range of particle shapes with smallest dimension down to 300 ?m. So far we have studied rods, crosses, jacks, tetrads, and helical shapes. We extract the particle orientations from stereoscopic video images using a method of least squares optimization in Euler angle space. We find that in turbulence the orientation and rotation rate of many particles can be understood using a simple picture of alignment of both the vorticity and a long axis of the particle with the Lagrangian stretching direction of the flow.

  2. Assessment of eye fatigue caused by 3D displays based on multimodal measurements.

    PubMed

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  3. Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

    PubMed Central

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  4. 3D measurement of the position of gold particles via evanescent digital holographic particle tracking velocimetry

    NASA Astrophysics Data System (ADS)

    Satake, Shin-ichi; Unno, Noriyuki; Nakata, Shuichiro; Taniguchi, Jun

    2016-08-01

    A new technique based on digital holography and evanescent waves was developed for 3D measurements of the position of gold nanoparticles in water. In this technique, an intensity profile is taken from a holographic image of a gold particle. To detect the position of the gold particle with high accuracy, its holographic image is recorded on a nanosized step made of MEXFLON, which has a refractive index close to that of water, and the position of the particle is reconstructed by means of digital holography. The height of the nanosized step was measured by using a profilometer and the digitally reconstructed height of the glass substrate had good agreement with the measured value. Furthermore, this method can be used to accurately track the 3D position of a gold particle in water.

  5. The effect of motion on IMRT - looking at interplay with 3D measurements

    NASA Astrophysics Data System (ADS)

    Thomas, A.; Yan, H.; Oldham, M.; Juang, T.; Adamovics, J.; Yin, F. F.

    2013-06-01

    Clinical recommendations to address tumor motion management have been derived from studies dealing with simulations and 2D measurements. 3D measurements may provide more insight and possibly alter the current motion management guidelines. This study provides an initial look at true 3D measurements involving leaf motion deliveries by use of a motion phantom and the PRESAGE/DLOS dosimetry system. An IMRT and VMAT plan were delivered to the phantom and analyzed by means of DVHs to determine whether the expansion of treatment volumes based on known imaging motion adequately cover the target. DVHs confirmed that for these deliveries the expansion volumes were adequate to treat the intended target although further studies should be conducted to allow for differences in parameters that could alter the results, such as delivery dose and breathe rate.

  6. The Evaluation of Steam Generator Level Measurement Model for OPR1000 Using RETRAN-3D

    SciTech Connect

    Doo Yong Lee; Soon Joon Hong; Byung Chul Lee; Heok Soon Lim

    2006-07-01

    Steam generator level measurement is important factor for plant transient analyses using best estimate thermal hydraulic computer codes since the value of steam generator level is used for steam generator level control system and plant protection system. Because steam generator is in the saturation condition which includes steam and liquid together and is the place that heat exchange occurs from primary side to secondary side, computer codes are hard to calculate steam generator level realistically without appropriate level measurement model. In this paper, we prepare the steam generator models using RETRAN-3D that include geometry models, full range feedwater control system and five types of steam generator level measurement model. Five types of steam generator level measurement model consist of level measurement model using elevation difference in downcomer, 1D level measurement model using fluid mass, 1D level measurement model using fluid volume, 2D level measurement model using power and fluid mass, and 2D level measurement model using power and fluid volume. And we perform the evaluation of the capability of each steam generator level measurement model by simulating the real plant transient condition, the title is 'Reactor Trip by The Failure of The Deaerator Level Control Card of Ulchin Unit 3'. The comparison results between real plant data and RETRAN-3D analyses for each steam generator level measurement model show that 2D level measurement model using power and fluid mass or fluid volume has more realistic prediction capability compared with other level measurement models. (authors)

  7. Automated 3D quantitative assessment and measurement of alpha angles from the femoral head-neck junction using MR imaging

    NASA Astrophysics Data System (ADS)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S.; Walker, Duncan; Crozier, Stuart; Engstrom, Craig

    2015-10-01

    To develop an automated approach for 3D quantitative assessment and measurement of alpha angles from the femoral head-neck (FHN) junction using bone models derived from magnetic resonance (MR) images of the hip joint. Bilateral MR images of the hip joints were acquired from 30 male volunteers (healthy active individuals and high-performance athletes, aged 18-49 years) using a water-excited 3D dual echo steady state (DESS) sequence. In a subset of these subjects (18 water-polo players), additional True Fast Imaging with Steady-state Precession (TrueFISP) images were acquired from the right hip joint. For both MR image sets, an active shape model based algorithm was used to generate automated 3D bone reconstructions of the proximal femur. Subsequently, a local coordinate system of the femur was constructed to compute a 2D shape map to project femoral head sphericity for calculation of alpha angles around the FHN junction. To evaluate automated alpha angle measures, manual analyses were performed on anterosuperior and anterior radial MR slices from the FHN junction that were automatically reformatted using the constructed coordinate system. High intra- and inter-rater reliability (intra-class correlation coefficients  >  0.95) was found for manual alpha angle measurements from the auto-extracted anterosuperior and anterior radial slices. Strong correlations were observed between manual and automatic measures of alpha angles for anterosuperior (r  =  0.84) and anterior (r  =  0.92) FHN positions. For matched DESS and TrueFISP images, there were no significant differences between automated alpha angle measures obtained from the upper anterior quadrant of the FHN junction (two-way repeated measures ANOVA, F  <  0.01, p  =  0.98). Our automatic 3D method analysed MR images of the hip joints to generate alpha angle measures around the FHN junction circumference with very good reliability and reproducibility. This work has the

  8. Automated 3D quantitative assessment and measurement of alpha angles from the femoral head-neck junction using MR imaging.

    PubMed

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S; Walker, Duncan; Crozier, Stuart; Engstrom, Craig

    2015-10-01

    To develop an automated approach for 3D quantitative assessment and measurement of alpha angles from the femoral head-neck (FHN) junction using bone models derived from magnetic resonance (MR) images of the hip joint.Bilateral MR images of the hip joints were acquired from 30 male volunteers (healthy active individuals and high-performance athletes, aged 18–49 years) using a water-excited 3D dual echo steady state (DESS) sequence. In a subset of these subjects (18 water-polo players), additional True Fast Imaging with Steady-state Precession (TrueFISP) images were acquired from the right hip joint. For both MR image sets, an active shape model based algorithm was used to generate automated 3D bone reconstructions of the proximal femur. Subsequently, a local coordinate system of the femur was constructed to compute a 2D shape map to project femoral head sphericity for calculation of alpha angles around the FHN junction. To evaluate automated alpha angle measures, manual analyses were performed on anterosuperior and anterior radial MR slices from the FHN junction that were automatically reformatted using the constructed coordinate system.High intra- and inter-rater reliability (intra-class correlation coefficients  >  0.95) was found for manual alpha angle measurements from the auto-extracted anterosuperior and anterior radial slices. Strong correlations were observed between manual and automatic measures of alpha angles for anterosuperior (r  =  0.84) and anterior (r  =  0.92) FHN positions. For matched DESS and TrueFISP images, there were no significant differences between automated alpha angle measures obtained from the upper anterior quadrant of the FHN junction (two-way repeated measures ANOVA, F  <  0.01, p  =  0.98).Our automatic 3D method analysed MR images of the hip joints to generate alpha angle measures around the FHN junction circumference with very good reliability and reproducibility. This work has the

  9. Mutual information as a measure of image quality for 3D dynamic lung imaging with EIT

    PubMed Central

    Crabb, M G; Davidson, J L; Little, R; Wright, P; Morgan, A R; Miller, C A; Naish, J H; Parker, G J M; Kikinis, R; McCann, H; Lionheart, W R B

    2014-01-01

    We report on a pilot study of dynamic lung electrical impedance tomography (EIT) at the University of Manchester. Low-noise EIT data at 100 frames per second (fps) were obtained from healthy male subjects during controlled breathing, followed by magnetic resonance imaging (MRI) subsequently used for spatial validation of the EIT reconstruction. The torso surface in the MR image and electrode positions obtained using MRI fiducial markers informed the construction of a 3D finite element model extruded along the caudal-distal axis of the subject. Small changes in the boundary that occur during respiration were accounted for by incorporating the sensitivity with respect to boundary shape into a robust temporal difference reconstruction algorithm. EIT and MRI images were co-registered using the open source medical imaging software, 3D Slicer. A quantitative comparison of quality of different EIT reconstructions was achieved through calculation of the mutual information with a lung-segmented MR image. EIT reconstructions using a linear shape correction algorithm reduced boundary image artefacts, yielding better contrast of the lungs, and had 10% greater mutual information compared with a standard linear EIT reconstruction. PMID:24710978

  10. 3D X-rays application for precision measurement of the cell structure of extruded polystyrene

    NASA Astrophysics Data System (ADS)

    Lim, J. Y.; Kim, K. Y.; Shin, H. S.; Yeom, S.; Lee, S. E.

    2015-12-01

    While the thermal performance of existing insulation materials have been determined by blister gases, the thermal performance of future insulation materials will be dependent on the cell size and independent foam content as we use eco-friendly blister gases with a higher thermal conductivity. However, with the current technology we are only able to guess the whole cell size and independent foam content through SEM applied 2D fragmentary scanning but are still far from the level of accurate cell structure data extraction. Under this situation, we utilized X-ray CT scanned 3D images to identify and shape the cell structure and proposed a method of inferring the whole distribution and independent foam content as accurately as possible. According to X-ray CT scanning images and SEM images, the shape was similar but according to tracer applied CT scanning images, the cell size distribution was 380∼400 pm within the range of the general insulation diameter distribution which had the highest reliability. As for extrusion foaming polystyrene, we need additional image processing to identify the independent foam content as its density is too low. So, it is recommended to raise the 3D cell structure completeness of XPS by improving the scanning accuracy.

  11. Longitudinal Measurement of Extracellular Matrix Rigidity in 3D Tumor Models Using Particle-tracking Microrheology

    PubMed Central

    El-Hamidi, Hamid; Celli, Jonathan P.

    2014-01-01

    The mechanical microenvironment has been shown to act as a crucial regulator of tumor growth behavior and signaling, which is itself remodeled and modified as part of a set of complex, two-way mechanosensitive interactions. While the development of biologically-relevant 3D tumor models have facilitated mechanistic studies on the impact of matrix rheology on tumor growth, the inverse problem of mapping changes in the mechanical environment induced by tumors remains challenging. Here, we describe the implementation of particle-tracking microrheology (PTM) in conjunction with 3D models of pancreatic cancer as part of a robust and viable approach for longitudinally monitoring physical changes in the tumor microenvironment, in situ. The methodology described here integrates a system of preparing in vitro 3D models embedded in a model extracellular matrix (ECM) scaffold of Type I collagen with fluorescently labeled probes uniformly distributed for position- and time-dependent microrheology measurements throughout the specimen. In vitro tumors are plated and probed in parallel conditions using multiwell imaging plates. Drawing on established methods, videos of tracer probe movements are transformed via the Generalized Stokes Einstein Relation (GSER) to report the complex frequency-dependent viscoelastic shear modulus, G*(ω). Because this approach is imaging-based, mechanical characterization is also mapped onto large transmitted-light spatial fields to simultaneously report qualitative changes in 3D tumor size and phenotype. Representative results showing contrasting mechanical response in sub-regions associated with localized invasion-induced matrix degradation as well as system calibration, validation data are presented. Undesirable outcomes from common experimental errors and troubleshooting of these issues are also presented. The 96-well 3D culture plating format implemented in this protocol is conducive to correlation of microrheology measurements with therapeutic

  12. A comparison of the 3D kinematic measurements obtained by single-plane 2D-3D image registration and RSA.

    PubMed

    Muhit, Abdullah A; Pickering, Mark R; Ward, Tom; Scarvell, Jennie M; Smith, Paul N

    2010-01-01

    3D computed tomography (CT) to single-plane 2D fluoroscopy registration is an emerging technology for many clinical applications such as kinematic analysis of human joints and image-guided surgery. However, previous registration approaches have suffered from the inaccuracy of determining precise motion parameters for out-of-plane movements. In this paper we compare kinematic measurements obtained by a new 2D-3D registration algorithm with measurements provided by the gold standard Roentgen Stereo Analysis (RSA). In particular, we are interested in the out-of-plane translation and rotations which are difficult to measure precisely using a single plane approach. Our experimental results show that the standard deviation of the error for out-of-plane translation is 0.42 mm which compares favourably to RSA. It is also evident that our approach produces very similar flexion/extension, abduction/adduction and external knee rotation angles when compared to RSA. PMID:21097358

  13. Microfabricated tissue gauges to measure and manipulate forces from 3D microtissues

    PubMed Central

    Legant, Wesley R.; Pathak, Amit; Yang, Michael T.; Deshpande, Vikram S.; McMeeking, Robert M.; Chen, Christopher S.

    2009-01-01

    Physical forces generated by cells drive morphologic changes during development and can feedback to regulate cellular phenotypes. Because these phenomena typically occur within a 3-dimensional (3D) matrix in vivo, we used microelectromechanical systems (MEMS) technology to generate arrays of microtissues consisting of cells encapsulated within 3D micropatterned matrices. Microcantilevers were used to simultaneously constrain the remodeling of a collagen gel and to report forces generated during this process. By concurrently measuring forces and observing matrix remodeling at cellular length scales, we report an initial correlation and later decoupling between cellular contractile forces and changes in tissue morphology. Independently varying the mechanical stiffness of the cantilevers and collagen matrix revealed that cellular forces increased with boundary or matrix rigidity whereas levels of cytoskeletal and extracellular matrix (ECM) proteins correlated with levels of mechanical stress. By mapping these relationships between cellular and matrix mechanics, cellular forces, and protein expression onto a bio-chemo-mechanical model of microtissue contractility, we demonstrate how intratissue gradients of mechanical stress can emerge from collective cellular contractility and finally, how such gradients can be used to engineer protein composition and organization within a 3D tissue. Together, these findings highlight a complex and dynamic relationship between cellular forces, ECM remodeling, and cellular phenotype and describe a system to study and apply this relationship within engineered 3D microtissues. PMID:19541627

  14. Automated 3D trajectory measuring of large numbers of moving particles.

    PubMed

    Wu, Hai Shan; Zhao, Qi; Zou, Danping; Chen, Yan Qiu

    2011-04-11

    Complex dynamics of natural particle systems, such as insect swarms, bird flocks, fish schools, has attracted great attention of scientists for years. Measuring 3D trajectory of each individual in a group is vital for quantitative study of their dynamic properties, yet such empirical data is rare mainly due to the challenges of maintaining the identities of large numbers of individuals with similar visual features and frequent occlusions. We here present an automatic and efficient algorithm to track 3D motion trajectories of large numbers of moving particles using two video cameras. Our method solves this problem by formulating it as three linear assignment problems (LAP). For each video sequence, the first LAP obtains 2D tracks of moving targets and is able to maintain target identities in the presence of occlusions; the second one matches the visually similar targets across two views via a novel technique named maximum epipolar co-motion length (MECL), which is not only able to effectively reduce matching ambiguity but also further diminish the influence of frequent occlusions; the last one links 3D track segments into complete trajectories via computing a globally optimal assignment based on temporal and kinematic cues. Experiment results on simulated particle swarms with various particle densities validated the accuracy and robustness of the proposed method. As real-world case, our method successfully acquired 3D flight paths of fruit fly (Drosophila melanogaster) group comprising hundreds of freely flying individuals. PMID:21503074

  15. Standardization based on human factors for 3D display: performance characteristics and measurement methods

    NASA Astrophysics Data System (ADS)

    Uehara, Shin-ichi; Ujike, Hiroyasu; Hamagishi, Goro; Taira, Kazuki; Koike, Takafumi; Kato, Chiaki; Nomura, Toshio; Horikoshi, Tsutomu; Mashitani, Ken; Yuuki, Akimasa; Izumi, Kuniaki; Hisatake, Yuzo; Watanabe, Naoko; Umezu, Naoaki; Nakano, Yoshihiko

    2010-02-01

    We are engaged in international standardization activities for 3D displays. We consider that for a sound development of 3D displays' market, the standards should be based on not only mechanism of 3D displays, but also human factors for stereopsis. However, we think that there is no common understanding on what the 3D display should be and that the situation makes developing the standards difficult. In this paper, to understand the mechanism and human factors, we focus on a double image, which occurs in some conditions on an autostereoscopic display. Although the double image is generally considered as an unwanted effect, we consider that whether the double image is unwanted or not depends on the situation and that there are some allowable double images. We tried to classify the double images into the unwanted and the allowable in terms of the display mechanism and visual ergonomics for stereopsis. The issues associated with the double image are closely related to performance characteristics for the autostereoscopic display. We also propose performance characteristics, measurement and analysis methods to represent interocular crosstalk and motion parallax.

  16. Chemical Synthesis of Sea-Urchin Shaped 3D-MnO2 Nano Structures and Their Application in Supercapacitors.

    PubMed

    Singu, Bal Sydulu; Hong, Sang Eun; Yoon, Kuk Ro

    2016-06-01

    Sea-urchin shaped α-MnO2 hierarchical nano structures have been synthesized by facile thermal method without using any hard or soft template under the mild conditions. The structural and morphology of the 3D-MnO2 was characterized by X-ray diffraction (XRD) and field emission scanning electron microscopy (FE-SEM). From the XRD analysis indicates that MnO2 present in the α form. Morphology analysis shows that α-MnO2 sea-urchins are made by stacked nanorods, the diameter and length of the stacked nanorods present in the range of 50-120 nm and 200-400 nm respectively. The electrochemical behaviour of α-MnO2 has been investigated by cyclic voltammetry (CV) and charge-discharge (CD). The specific capacitance, energy density and power density are 212.0 F g(-1), 21.2 Wh kg(-1) and 1200 W kg(-1) respectively at the current density of 2 A g(-1). The retention of the specific capacitance after completion of 1000 charge-discharge cycles is around 97%. The results reveal that the prepared Sea-urchin shaped α-MnO2 has high specific capacitance and exhibit excellent cycle life. PMID:27427676

  17. Microfabrics and 3D grain shape of Gorleben rock salt: Constraints on deformation mechanisms and paleodifferential stress

    NASA Astrophysics Data System (ADS)

    Thiemeyer, Nicolas; Zulauf, Gernold; Mertineit, Michael; Linckens, Jolien; Pusch, Maximilian; Hammer, Jörg

    2016-04-01

    The Permian Knäuel- and Streifensalz formations (z2HS1 and z2HS2) are main constituents of the Gorleben salt dome (Northern Germany) and show different amounts and distributions of anhydrite. The reconstruction of 3D halite grain shape ellipsoids reveals small grain size (3.4 ± 0.6 mm) and heterogeneous grain shapes in both formations, the latter attributed to the polyphase deformation of the rock salt during diapirism. The halite microfabrics of both formations indicate that strain-induced grain boundary migration was active during deformation. Crystal plastic deformation of halite is further documented by lattice bending, subgrain formation and minor subgrain rotation. Evidence for pressure solution of halite has not been found, but cannot be excluded because of the small grain size, the lack of LPO and the low differential stress (1.1-1.3 MPa) as deduced from subgrain-size piezometry. Anhydrite has been deformed in the brittle-ductile regime by solution precipitation creep, minor dislocation creep and brittle boudinage. No continuous anhydrite layers are preserved, and halite has acted as a sealing matrix embedding the disrupted anhydrite fragments prohibiting any potential migration pathways for fluids. Thus, anhydrite should not have a negative effect on the barrier properties of the Gorleben rock salts investigated in this study.

  18. 3D optical measurement of relative displacement for the tuberosities in the shoulder prosthesis

    NASA Astrophysics Data System (ADS)

    Yao, XueFeng; Meng, LiBo; Yu, LiuPing; Zhu, YiMing; Jiang, ChunYan

    2011-04-01

    In this paper, a binocular 3-D computer vision measurement system is used to measure the relative displacement for the greater and lesser tuberosities in the shoulder prosthesis. The basic principles of binocular optical measurement are introduced in detail, and the loading apparatus is designed for external rotation and anteflexion of the shoulder prosthesis. Both the motion of external rotation and anteflexion of the shoulder are measured, and the corresponding displacement values for the greater and lesser tuberosities are extracted. These results will play an important role in evaluating the stability of humeral tuberosity in the shoulder prosthesis.

  19. Three-dimensional shape measurement of small object based on tri-frequency heterodyne method

    NASA Astrophysics Data System (ADS)

    Liu, Shouqi; Feng, Wei; Zhang, Qican; Liu, Yuankun

    2015-08-01

    Among temporal phase unwrapping methods based on structured light projection, tri-frequency heterodyne method, with the merits of less projected fringe, high precision and high reliability, has become a practical method in objects three-dimensional (3D) shape measurement. In this paper, a 3D shape measuring system was developed with a digital micromirror device (DMD) and synchronously trigged CCD camera. The 3D shape of a measured object was reconstructed from the deformed fringe patterns based on tri-frequency heterodyne method. The practical experiments were carried on some coins, and the results show that the system can restore their 3D shape on the tested partition with an accuracy of microns. This measurement system is prominent in 3D shape measurement of small or tiny objects, sample testing, and many other application fields.

  20. Fast error simulation of optical 3D measurements at translucent objects

    NASA Astrophysics Data System (ADS)

    Lutzke, P.; Kühmstedt, P.; Notni, G.

    2012-09-01

    The scan results of optical 3D measurements at translucent objects deviate from the real objects surface. This error is caused by the fact that light is scattered in the objects volume and is not exclusively reflected at its surface. A few approaches were made to separate the surface reflected light from the volume scattered. For smooth objects the surface reflected light is dominantly concentrated in specular direction and could only be observed from a point in this direction. Thus the separation either leads to measurement results only creating data for near specular directions or provides data from not well separated areas. To ensure the flexibility and precision of optical 3D measurement systems for translucent materials it is necessary to enhance the understanding of the error forming process. For this purpose a technique for simulating the 3D measurement at translucent objects is presented. A simple error model is shortly outlined and extended to an efficient simulation environment based upon ordinary raytracing methods. In comparison the results of a Monte-Carlo simulation are presented. Only a few material and object parameters are needed for the raytracing simulation approach. The attempt of in-system collection of these material and object specific parameters is illustrated. The main concept of developing an error-compensation method based on the simulation environment and the collected parameters is described. The complete procedure is using both, the surface reflected and the volume scattered light for further processing.

  1. 3D measurement method based on combined temporal encoding structured light

    NASA Astrophysics Data System (ADS)

    Yu, Xiaoyang; Wang, Yang; Yu, Shuang; Cheng, Hao; Sun, Xiaoming; Yu, Shuchun; Chen, Deyun

    2013-10-01

    Three-dimensional (3D) vision measurement technology based on encoding structured light plays an important role and has become the main development trend in the field of 3D non-contact measurement. However, how to synthetically improve measurement speed, accuracy and sampling density is still a difficult problem. Thus in the present work, a novel 3D measurement method based on temporal encoding structured light by combining trapezoidal phase-shifting pattern and cyclic code pattern is proposed. Due to trapezoidal phase-shifting has the advantages of high sampling density and high-speed, the proposed method can maintain these advantages by using cyclic code to expand the range of trapezoidal phase-shifting. In addition, the correction scheme is designed to solve the problem of cycle dislocation. Finally, simulation experimental platform is built with 3ds max and MATLAB. Experimental analyses and results show that, the maximal error is less than 3 mm in the range from 400 mm to 1100 mm, cycle dislocation correction has a good effect.

  2. Visualization of anthropometric measures of workers in computer 3D modeling of work place.

    PubMed

    Mijović, B; Ujević, D; Baksa, S

    2001-12-01

    In this work, 3D visualization of a work place by means of a computer-made 3D-machine model and computer animation of a worker have been performed. By visualization of 3D characters in inverse kinematic and dynamic relation with the operating part of a machine, the biomechanic characteristics of worker's body have been determined. The dimensions of a machine have been determined by an inspection of technical documentation as well as by direct measurements and recordings of the machine by camera. On the basis of measured body height of workers all relevant anthropometric measures have been determined by a computer program developed by the authors. By knowing the anthropometric measures, the vision fields and the scope zones while forming work places, exact postures of workers while performing technological procedures were determined. The minimal and maximal rotation angles and the translation of upper and lower arm which are basis for the analysis of worker burdening were analyzed. The dimensions of the seized space of a body are obtained by computer anthropometric analysis of movement, e.g. range of arms, position of legs, head, back. The influence of forming of a work place on correct postures of workers during work has been reconsidered and thus the consumption of energy and fatigue can be reduced to a minimum. PMID:11811295

  3. Optical fiber sensor system for oil contamination measurement based on 3D fluorescence spectrum parameterization

    NASA Astrophysics Data System (ADS)

    Shang, Liping; Shi, Jinshan

    2000-10-01

    In recent years oil contamination in water is more serious and destroys the mode of life and relation to water body environments. Excitation fluorescence method is one of the main approaches to monitor oil contamination on line. But average intensity of oil fluorescence only indicates its density, not indicates the type of contamination oil. Two-dimensional fluorescence spectrum is more difficult to determine the kind of oil, because the different oil has fluorescence spectrum overlapping to a great extent. In this paper, the 3D fluorescence spectrum parameterization is introduced. It can extract several characteristic parameters to measure the kid of oil to be measured. A prototype of optical fiber 3D fluorescence spectrum meter we developed carries out the identification of different oil types, such as crude oil, diesel oil and kerosene. The experiment arrangement conceived to measure pulse xenon lamp induced of oil component in water. The experiment results state clearly that the 3D fluorescence spectrum parameterization and software are successful to measure oil density and identify the type of oil in situ.

  4. 3D real-time measurement system of seam with laser

    NASA Astrophysics Data System (ADS)

    Huang, Min-shuang; Huang, Jun-fen

    2014-02-01

    3-D Real-time Measurement System of seam outline based on Moiré Projection is proposed and designed. The system is composed of LD, grating, CCD, video A/D, FPGA, DSP and an output interface. The principle and hardware makeup of high-speed and real-time image processing circuit based on a Digital Signal Processor (DSP) and a Field Programmable Gate Array (FPGA) are introduced. Noise generation mechanism in poor welding field conditions is analyzed when Moiré stripes are projected on a welding workpiece surface. Median filter is adopted to smooth the acquired original laser image of seam, and then measurement results of a 3-D outline image of weld groove are provided.

  5. Measurement error analysis of the 3D four-wheel aligner

    NASA Astrophysics Data System (ADS)

    Zhao, Qiancheng; Yang, Tianlong; Huang, Dongzhao; Ding, Xun

    2013-10-01

    Positioning parameters of four-wheel have significant effects on maneuverabilities, securities and energy saving abilities of automobiles. Aiming at this issue, the error factors of 3D four-wheel aligner, which exist in extracting image feature points, calibrating internal and exeternal parameters of cameras, calculating positional parameters and measuring target pose, are analyzed respectively based on the elaborations of structure and measurement principle of 3D four-wheel aligner, as well as toe-in and camber of four-wheel, kingpin inclination and caster, and other major positional parameters. After that, some technical solutions are proposed for reducing the above error factors, and on this basis, a new type of aligner is developed and marketed, it's highly estimated among customers because the technical indicators meet requirements well.

  6. Unequal-period combination approach of gray code and phase-shifting for 3-D visual measurement

    NASA Astrophysics Data System (ADS)

    Yu, Shuang; Zhang, Jing; Yu, Xiaoyang; Sun, Xiaoming; Wu, Haibin

    2016-09-01

    Combination of Gray code and phase-shifting is the most practical and advanced approach for the structured light 3-D measurement so far, which is able to measure objects with complex and discontinuous surface. However, for the traditional combination of the Gray code and phase-shifting, the captured Gray code images are not always sharp cut-off in the black-white conversion boundaries, which may lead to wrong decoding analog code orders. Moreover, during the actual measurement, there also exists local decoding error for the wrapped analog code obtained with the phase-shifting approach. Therefore, for the traditional approach, the wrong analog code orders and the local decoding errors will consequently introduce the errors which are equivalent to a fringe period when the analog code is unwrapped. In order to avoid one-fringe period errors, we propose an approach which combines Gray code with phase-shifting according to unequal period. With theoretical analysis, we build the measurement model of the proposed approach, determine the applicable condition and optimize the Gray code encoding period and phase-shifting fringe period. The experimental results verify that the proposed approach can offer a reliable unwrapped analog code, which can be used in 3-D shape measurement.

  7. Comparison of measuring strategies for the 3-D electrical resistivity imaging of tumuli

    NASA Astrophysics Data System (ADS)

    Tsourlos, Panagiotis; Papadopoulos, Nikos; Yi, Myeong-Jong; Kim, Jung-Ho; Tsokas, Gregory

    2014-02-01

    Artificial erected hills like tumuli, mounds, barrows and kurgans comprise monuments of the past human activity and offer opportunities to reconstruct habitation models regarding the life and customs during their building period. These structures also host features of archeological significance like architectural relics, graves or chamber tombs. Tumulus exploration is a challenging geophysical problem due to the complex distribution of the subsurface physical properties, the size and burial depth of potential relics and the uneven topographical terrain. Geoelectrical methods by means of three-dimensional (3-D) inversion are increasingly popular for tumulus investigation. Typically data are obtained by establishing a regular rectangular grid and assembling the data collected by parallel two-dimensional (2-D) tomographies. In this work the application of radial 3-D mode is studied, which is considered as the assembly of data collected by radially positioned Electrical Resistivity Tomography (ERT) lines. The relative advantages and disadvantages of this measuring mode over the regular grid measurements were investigated and optimum ways to perform 3-D ERT surveys for tumuli investigations were proposed. Comparative test was performed by means of synthetic examples as well as by tests with field data. Overall all tested models verified the superiority of the radial mode in delineating bodies positioned at the central part of the tumulus while regular measuring mode proved superior in recovering bodies positioned away from the center of the tumulus. The combined use of radial and regular modes seems to produce superior results in the expense of time required for data acquisition and processing.

  8. Measuring the correlation between cell mechanics and myofibroblastic differentiation during maturation of 3D microtissues

    NASA Astrophysics Data System (ADS)

    Zhao, Ruogang; Wang, Weigang; Boudou, Thomas; Chen, Christopher; Reich, Daniel

    2013-03-01

    Tissue stiffness and cellular contractility are two of the most important biomechanical factors regulating pathological transitions of encapsulated cells, such as the differentiation of fibroblasts into myofibroblasts - a key event contributing to tissue fibrosis. However, a quantitative correlation between tissue stiffness and cellular contraction and myofibroblast differentiation has not yet been established in 3D environments, mainly due to the lack of suitable 3D tissue culture models that allow both tissue remodeling and simultaneous measurement of the cell/tissue mechanics. To address this, we have developed a magnetic microtissue tester system that allows the remodeling of arrays of cell-laden 3D collagen microtissues and the measurement of cell and tissue mechanics using magnetically actuated elastomeric microcantilevers. By measuring the development of cell/tissue mechanical properties and the expression level of α-smooth muscle actin (α-SMA, a marker for myofibroblast differentiation) during a 6 day culture period, we found microtissue stiffness increased by 45% and α-SMA expression increased by 38%, but tissue contraction forces only increased by 10%, indicating that tissue stiffness may be the predominant mechanical factor for regulation of myofibroblast differentiation. This study provides new quantitative insight into the regulatory effect of cell and tissue mechanics on cellular function. Supported in part by NIH grant HL090747

  9. Automatic 3D segmentation of the kidney in MR images using wavelet feature extraction and probability shape model

    NASA Astrophysics Data System (ADS)

    Akbari, Hamed; Fei, Baowei

    2012-02-01

    Numerical estimation of the size of the kidney is useful in evaluating conditions of the kidney, especially, when serial MR imaging is performed to evaluate the kidney function. This paper presents a new method for automatic segmentation of the kidney in three-dimensional (3D) MR images, by extracting texture features and statistical matching of geometrical shape of the kidney. A set of Wavelet-based support vector machines (W-SVMs) is trained on the MR images. The W-SVMs capture texture priors of MRI for classification of the kidney and non-kidney tissues in different zones around the kidney boundary. In the segmentation procedure, these W-SVMs are trained to tentatively label each voxel around the kidney model as a kidney or non-kidney voxel by texture matching. A probability kidney model is created using 10 segmented MRI data. The model is initially localized based on the intensity profiles in three directions. The weight functions are defined for each labeled voxel for each Wavelet-based, intensity-based, and model-based label. Consequently, each voxel has three labels and three weights for the Wavelet feature, intensity, and probability model. Using a 3D edge detection method, the model is re-localized and the segmented kidney is modified based on a region growing method in the model region. The probability model is re-localized based on the results and this loop continues until the segmentation converges. Experimental results with mouse MRI data show the good performance of the proposed method in segmenting the kidney in MR images.

  10. Examination about Influence for Precision of 3d Image Measurement from the Ground Control Point Measurement and Surface Matching

    NASA Astrophysics Data System (ADS)

    Anai, T.; Kochi, N.; Yamada, M.; Sasaki, T.; Otani, H.; Sasaki, D.; Nishimura, S.; Kimoto, K.; Yasui, N.

    2015-05-01

    As the 3D image measurement software is now widely used with the recent development of computer-vision technology, the 3D measurement from the image is now has acquired the application field from desktop objects as wide as the topography survey in large geographical areas. Especially, the orientation, which used to be a complicated process in the heretofore image measurement, can be now performed automatically by simply taking many pictures around the object. And in the case of fully textured object, the 3D measurement of surface features is now done all automatically from the orientated images, and greatly facilitated the acquisition of the dense 3D point cloud from images with high precision. With all this development in the background, in the case of small and the middle size objects, we are now furnishing the all-around 3D measurement by a single digital camera sold on the market. And we have also developed the technology of the topographical measurement with the air-borne images taken by a small UAV [1~5]. In this present study, in the case of the small size objects, we examine the accuracy of surface measurement (Matching) by the data of the experiments. And as to the topographic measurement, we examine the influence of GCP distribution on the accuracy by the data of the experiments. Besides, we examined the difference of the analytical results in each of the 3D image measurement software. This document reviews the processing flow of orientation and the 3D measurement of each software and explains the feature of the each software. And as to the verification of the precision of stereo-matching, we measured the test plane and the test sphere of the known form and assessed the result. As to the topography measurement, we used the air-borne image data photographed at the test field in Yadorigi of Matsuda City, Kanagawa Prefecture JAPAN. We have constructed Ground Control Point which measured by RTK-GPS and Total Station. And we show the results of analysis made

  11. 3D nonrigid medical image registration using a new information theoretic measure.

    PubMed

    Li, Bicao; Yang, Guanyu; Coatrieux, Jean Louis; Li, Baosheng; Shu, Huazhong

    2015-11-21

    This work presents a novel method for the nonrigid registration of medical images based on the Arimoto entropy, a generalization of the Shannon entropy. The proposed method employed the Jensen-Arimoto divergence measure as a similarity metric to measure the statistical dependence between medical images. Free-form deformations were adopted as the transformation model and the Parzen window estimation was applied to compute the probability distributions. A penalty term is incorporated into the objective function to smooth the nonrigid transformation. The goal of registration is to optimize an objective function consisting of a dissimilarity term and a penalty term, which would be minimal when two deformed images are perfectly aligned using the limited memory BFGS optimization method, and thus to get the optimal geometric transformation. To validate the performance of the proposed method, experiments on both simulated 3D brain MR images and real 3D thoracic CT data sets were designed and performed on the open source elastix package. For the simulated experiments, the registration errors of 3D brain MR images with various magnitudes of known deformations and different levels of noise were measured. For the real data tests, four data sets of 4D thoracic CT from four patients were selected to assess the registration performance of the method, including ten 3D CT images for each 4D CT data covering an entire respiration cycle. These results were compared with the normalized cross correlation and the mutual information methods and show a slight but true improvement in registration accuracy. PMID:26528821

  12. Precision and accuracy of 3D lower extremity residua measurement systems

    NASA Astrophysics Data System (ADS)

    Commean, Paul K.; Smith, Kirk E.; Vannier, Michael W.; Hildebolt, Charles F.; Pilgram, Thomas K.

    1996-04-01

    Accurate and reproducible geometric measurement of lower extremity residua is required for custom prosthetic socket design. We compared spiral x-ray computed tomography (SXCT) and 3D optical surface scanning (OSS) with caliper measurements and evaluated the precision and accuracy of each system. Spiral volumetric CT scanned surface and subsurface information was used to make external and internal measurements, and finite element models (FEMs). SXCT and OSS were used to measure lower limb residuum geometry of 13 below knee (BK) adult amputees. Six markers were placed on each subject's BK residuum and corresponding plaster casts and distance measurements were taken to determine precision and accuracy for each system. Solid models were created from spiral CT scan data sets with the prosthesis in situ under different loads using p-version finite element analysis (FEA). Tissue properties of the residuum were estimated iteratively and compared with values taken from the biomechanics literature. The OSS and SXCT measurements were precise within 1% in vivo and 0.5% on plaster casts, and accuracy was within 3.5% in vivo and 1% on plaster casts compared with caliper measures. Three-dimensional optical surface and SXCT imaging systems are feasible for capturing the comprehensive 3D surface geometry of BK residua, and provide distance measurements statistically equivalent to calipers. In addition, SXCT can readily distinguish internal soft tissue and bony structure of the residuum. FEM can be applied to determine tissue material properties interactively using inverse methods.

  13. Design and verification of an ultra-precision 3D-coordinate measuring machine with parallel drives

    NASA Astrophysics Data System (ADS)

    Bos, Edwin; Moers, Ton; van Riel, Martijn

    2015-08-01

    An ultra-precision 3D coordinate measuring machine (CMM), the TriNano N100, has been developed. In our design, the workpiece is mounted on a 3D stage, which is driven by three parallel drives that are mutually orthogonal. The linear drives support the 3D stage using vacuum preloaded (VPL) air bearings, whereby each drive determines the position of the 3D stage along one translation direction only. An exactly constrained design results in highly repeatable machine behavior. Furthermore, the machine complies with the Abbé principle over its full measurement range and the application of parallel drives allows for excellent dynamic behavior. The design allows a 3D measurement uncertainty of 100 nanometers in a measurement range of 200 cubic centimeters. Verification measurements using a Gannen XP 3D tactile probing system on a spherical artifact show a standard deviation in single point repeatability of around 2 nm in each direction.

  14. Accurately measuring volume of soil samples using low cost Kinect 3D scanner

    NASA Astrophysics Data System (ADS)

    van der Sterre, Boy-Santhos; Hut, Rolf; van de Giesen, Nick

    2013-04-01

    The 3D scanner of the Kinect game controller can be used to increase the accuracy and efficiency of determining in situ soil moisture content. Soil moisture is one of the principal hydrological variables in both the water and energy interactions between soil and atmosphere. Current in situ measurements of soil moisture either rely on indirect measurements (of electromagnetic constants or heat capacity) or on physically taking a sample and weighing it in a lab. The bottleneck in accurately retrieving soil moisture using samples is the determining of the volume of the sample. Currently this is mostly done by the very time consuming "sand cone method" in which the volume were the sample used to sit is filled with sand. We show that 3D scanner that is part of the 150 game controller extension "Kinect" can be used to make 3D scans before and after taking the sample. The accuracy of this method is tested by scanning forms of known volume. This method is less time consuming and less error-prone than using a sand cone.

  15. Accurately measuring volume of soil samples using low cost Kinect 3D scanner

    NASA Astrophysics Data System (ADS)

    van der Sterre, B.; Hut, R.; Van De Giesen, N.

    2012-12-01

    The 3D scanner of the Kinect game controller can be used to increase the accuracy and efficiency of determining in situ soil moisture content. Soil moisture is one of the principal hydrological variables in both the water and energy interactions between soil and atmosphere. Current in situ measurements of soil moisture either rely on indirect measurements (of electromagnetic constants or heat capacity) or on physically taking a sample and weighing it in a lab. The bottleneck in accurately retrieving soil moisture using samples is the determining of the volume of the sample. Currently this is mostly done by the very time consuming "sand cone method" in which the volume were the sample used to sit is filled with sand. We show that 3D scanner that is part of the $150 game controller extension "Kinect" can be used to make 3D scans before and after taking the sample. The accuracy of this method is tested by scanning forms of known volume. This method is less time consuming and less error-prone than using a sand cone.

  16. 3D surface roughness measurement for scaliness scoring of psoriasis lesions.

    PubMed

    Ahmad Fadzil, M Hani; Prakasa, Esa; Asirvadam, Vijanth Sagayan; Nugroho, Hermawan; Affandi, Azura Mohd; Hussein, Suraiya Hani

    2013-11-01

    Psoriasis is an incurable skin disorder affecting 2-3% of the world population. The scaliness of psoriasis is a key assessment parameter of the Psoriasis Area and Severity Index (PASI). Dermatologists typically use visual and tactile senses in PASI scaliness assessment. However, the assessment can be subjective resulting in inter- and intra-rater variability in the scores. This paper proposes an assessment method that incorporates 3D surface roughness with standard clustering techniques to objectively determine the PASI scaliness score for psoriasis lesions. A surface roughness algorithm using structured light projection has been applied to 1999 3D psoriasis lesion surfaces. The algorithm has been validated with an accuracy of 94.12%. Clustering algorithms were used to classify the surface roughness measured using the proposed assessment method for PASI scaliness scoring. The reliability of the developed PASI scaliness algorithm was high with kappa coefficients>0.84 (almost perfect agreement). PMID:24054912

  17. Simultaneous 3D-vibration measurement using a single laser beam device

    NASA Astrophysics Data System (ADS)

    Brecher, Christian; Guralnik, Alexander; Baümler, Stephan

    2012-06-01

    Today's commercial solutions for vibration measurement and modal analysis are 3D-scanning laser doppler vibrometers, mainly used for open surfaces in the automotive and aerospace industries and the classic three-axial accelerometers in civil engineering, for most industrial applications in manufacturing environments, and particularly for partially closed structures. This paper presents a novel measurement approach using a single laser beam device and optical reflectors to simultaneously perform 3D-dynamic measurement as well as geometry measurement of the investigated object. We show the application of this so called laser tracker for modal testing of structures on a mechanical manufacturing shop floor. A holistic measurement method is developed containing manual reflector placement, semi-automated geometric modeling of investigated objects and fully automated vibration measurement up to 1000 Hz and down to few microns amplitude. Additionally the fast set up dynamic measurement of moving objects using a tracking technique is presented that only uses the device's own functionalities and does neither require a predefined moving path of the target nor an electronic synchronization to the moving object.

  18. 3D multifunctional integumentary membranes for spatiotemporal cardiac measurements and stimulation across the entire epicardium

    PubMed Central

    Xu, Lizhi; Gutbrod, Sarah R.; Bonifas, Andrew P.; Su, Yewang; Sulkin, Matthew S.; Lu, Nanshu; Chung, Hyun-Joong; Jang, Kyung-In; Liu, Zhuangjian; Ying, Ming; Lu, Chi; Webb, R. Chad; Kim, Jong-Seon; Laughner, Jacob I.; Cheng, Huanyu; Liu, Yuhao; Ameen, Abid; Jeong, Jae-Woong; Kim, Gwang-Tae; Huang, Yonggang; Efimov, Igor R.; Rogers, John A.

    2015-01-01

    Means for high-density multiparametric physiological mapping and stimulation are critically important in both basic and clinical cardiology. Current conformal electronic systems are essentially 2D sheets, which cannot cover the full epicardial surface or maintain reliable contact for chronic use without sutures or adhesives. Here we create 3D elastic membranes shaped precisely to match the epicardium of the heart via the use of 3D printing, as a platform for deformable arrays of multifunctional sensors, electronic and optoelectronic components. Such integumentary devices completely envelop the heart, in a form-fitting manner, and possess inherent elasticity, providing a mechanically stable bioti-/abiotic interface during normal cardiac cycles. Component examples range from actuators for electrical, thermal and optical stimulation, to sensors for pH, temperature and mechanical strain. The semiconductor materials include silicon, gallium arsenide and gallium nitride, co-integrated with metals, metal oxides and polymers, to provide these and other operational capabilities. Ex vivo physiological experiments demonstrate various functions and methodological possibilities for cardiac research and therapy. PMID:24569383

  19. 3D multifunctional integumentary membranes for spatiotemporal cardiac measurements and stimulation across the entire epicardium

    NASA Astrophysics Data System (ADS)

    Xu, Lizhi; Gutbrod, Sarah R.; Bonifas, Andrew P.; Su, Yewang; Sulkin, Matthew S.; Lu, Nanshu; Chung, Hyun-Joong; Jang, Kyung-In; Liu, Zhuangjian; Ying, Ming; Lu, Chi; Webb, R. Chad; Kim, Jong-Seon; Laughner, Jacob I.; Cheng, Huanyu; Liu, Yuhao; Ameen, Abid; Jeong, Jae-Woong; Kim, Gwang-Tae; Huang, Yonggang; Efimov, Igor R.; Rogers, John A.

    2014-02-01

    Means for high-density multiparametric physiological mapping and stimulation are critically important in both basic and clinical cardiology. Current conformal electronic systems are essentially 2D sheets, which cannot cover the full epicardial surface or maintain reliable contact for chronic use without sutures or adhesives. Here we create 3D elastic membranes shaped precisely to match the epicardium of the heart via the use of 3D printing, as a platform for deformable arrays of multifunctional sensors, electronic and optoelectronic components. Such integumentary devices completely envelop the heart, in a form-fitting manner, and possess inherent elasticity, providing a mechanically stable biotic/abiotic interface during normal cardiac cycles. Component examples range from actuators for electrical, thermal and optical stimulation, to sensors for pH, temperature and mechanical strain. The semiconductor materials include silicon, gallium arsenide and gallium nitride, co-integrated with metals, metal oxides and polymers, to provide these and other operational capabilities. Ex vivo physiological experiments demonstrate various functions and methodological possibilities for cardiac research and therapy.

  20. 3D multifunctional integumentary membranes for spatiotemporal cardiac measurements and stimulation across the entire epicardium.

    PubMed

    Xu, Lizhi; Gutbrod, Sarah R; Bonifas, Andrew P; Su, Yewang; Sulkin, Matthew S; Lu, Nanshu; Chung, Hyun-Joong; Jang, Kyung-In; Liu, Zhuangjian; Ying, Ming; Lu, Chi; Webb, R Chad; Kim, Jong-Seon; Laughner, Jacob I; Cheng, Huanyu; Liu, Yuhao; Ameen, Abid; Jeong, Jae-Woong; Kim, Gwang-Tae; Huang, Yonggang; Efimov, Igor R; Rogers, John A

    2014-01-01

    Means for high-density multiparametric physiological mapping and stimulation are critically important in both basic and clinical cardiology. Current conformal electronic systems are essentially 2D sheets, which cannot cover the full epicardial surface or maintain reliable contact for chronic use without sutures or adhesives. Here we create 3D elastic membranes shaped precisely to match the epicardium of the heart via the use of 3D printing, as a platform for deformable arrays of multifunctional sensors, electronic and optoelectronic components. Such integumentary devices completely envelop the heart, in a form-fitting manner, and possess inherent elasticity, providing a mechanically stable biotic/abiotic interface during normal cardiac cycles. Component examples range from actuators for electrical, thermal and optical stimulation, to sensors for pH, temperature and mechanical strain. The semiconductor materials include silicon, gallium arsenide and gallium nitride, co-integrated with metals, metal oxides and polymers, to provide these and other operational capabilities. Ex vivo physiological experiments demonstrate various functions and methodological possibilities for cardiac research and therapy. PMID:24569383

  1. 3D printing of soft and wet systems benefit from hard-to-soft transition of transparent shape memory gels (presentation video)

    NASA Astrophysics Data System (ADS)

    Furukawa, Hidemitsu; Gong, Jin; Makino, Masato; Kabir, Md. Hasnat

    2014-04-01

    Recently we successfully developed novel transparent shape memory gels. The SMG memorize their original shapes during the gelation process. In the room temperature, the SMG are elastic and show plasticity (yielding) under deformation. However when heated above about 50˚C, the SMG induce hard-to-soft transition and go back to their original shapes automatically. We focus on new soft and wet systems made of the SMG by 3-D printing technology.

  2. 3D measurement of the human body for apparel mass customization

    NASA Astrophysics Data System (ADS)

    Xu, Bugao; Lin, Sheng; Chen, Tong

    2000-12-01

    An automatic body measurement system is essential for apparel mass customization. This paper introduces the development of a body-scanning system using the multi-line triangulation technique, and methods for body size extraction and body modeling. The scanning system can rapidly acquire the surface data of a body, provide accurate body dimensions, many of which are not measurable with conventional methods, and also construct a body form based on the scanned data as a digital model of the body for 3D garment design and for virtual try-on of a designed garment.

  3. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    NASA Astrophysics Data System (ADS)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  4. An analogue contact probe using a compact 3D optical sensor for micro/nano coordinate measuring machines

    NASA Astrophysics Data System (ADS)

    Li, Rui-Jun; Fan, Kuang-Chao; Miao, Jin-Wei; Huang, Qiang-Xian; Tao, Sheng; Gong, Er-min

    2014-09-01

    This paper presents a new analogue contact probe based on a compact 3D optical sensor with high precision. The sensor comprises an autocollimator and a polarizing Michelson interferometer, which can detect two angles and one displacement of the plane mirror at the same time. In this probe system, a tungsten stylus with a ruby tip-ball is attached to a floating plate, which is supported by four V-shape leaf springs fixed to the outer case. When a contact force is applied to the tip, the leaf springs will experience elastic deformation and the plane mirror mounted on the floating plate will be displaced. The force-motion characteristics of this probe were investigated and optimum parameters were obtained with the constraint of allowable physical size of the probe. Simulation results show that the probe is uniform in 3D and its contacting force gradient is within 1 mN µm - 1. Experimental results indicate that the probe has 1 nm resolution,  ± 10 µm measuring range in X - Y plane, 10 µm measuring range in Z direction and within 30 nm measuring standard deviation. The feasibility of the probe has been preliminarily verified by testing the flatness and step height of high precision gauge blocks.

  5. Skin-friction measurements in a 3-D, supersonic shock-wave/boundary-layer interaction

    NASA Astrophysics Data System (ADS)

    Wideman, Jeffrey Kenneth

    An experimental study has been conducted in a three-dimensional, supersonic shockwave/boundary-layer interaction (3-D SW/BLI) with the intent of providing accurate experimental data for turbulence modeling and computational fluid dynamics (CFD) code validation. The experiment was performed in the High Reynolds Channel 1 (HRCI) wind tunnel at NASA Ames Research Center. The test was conducted at a Mach number of M(sub infinity) = 2.89 and at a Reynolds number of Re = 15 x 106/m. The model consisted of a sting-supported cylinder aligned with the tunnel axis and a 20 deg half-angle conical flare offset 1.27 cm from the cylinder centerline. The generated shock system was verified to be steady by schlieren visualization. The highlight of the study was the acquisition of 3-D skin-friction data by a laser interferometric skin friction (LISF) meter. Surface pressure measurements were obtained in 15 deg intervals around the cylinder and flare. Additional measurements included surface oil flow and laser light sheet illumination which were used to document the flow topology. Skin-friction measurements are proving to be a very challenging test of a CFD code predictive capability. However, at the present time there is a very limited amount of accurate skin-friction data in complex flows such as in 3-D SW/BLI. The LISF technique is advantageous as compared to other skin-friction measurement techniques for application in complex flows like the present since it is non-intrusive and is capable of performing measurements in flows with large shear and pressure gradients where the reliability of other techniques is questionable. Thus, the prevent skin-friction data will prove valuable to turbulence modeling and CFD code validation efforts.

  6. Development of energy efficient mixing strategies in egg-shaped anaerobic reactors through 3D CFD simulation.

    PubMed

    Hernandez-Aguilar, Eduardo; Alvarado-Lassman, Alejandro; Osorio-Mirón, Anselmo; Méndez-Contreras, Juan M

    2016-01-01

    This work describes a 3D computational fluid dynamic model, which characterizes the hydrodynamic behavior of a mixing strategy applied to egg-shaped reactors that lack a mechanical stirring device. The model is based on Navier-Stokes and material balance equations without a chemical reaction. To describe the behavior of mixing, initial water feed flows of 6, 7.5 and 9 mL s(-1) were used. An experimental validation was subsequently carried out using a pulse technique, with NaCl as a tracer. The residence time distributions were quantitatively determined. Then, the degradation process of the wastewater sludge was characterized by studying the time dependence of the dynamic viscosity, the concentration of volatile solids and the density of wastewater sludge. The data resulting were introduced into the validated model, and five feed flows from 9 to 13 mL s(-1), the best performance found was with feed flow of 11 mL s(-1). PMID:26950282

  7. Automatic 3D image registration using voxel similarity measurements based on a genetic algorithm

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Sullivan, John M., Jr.; Kulkarni, Praveen; Murugavel, Murali

    2006-03-01

    An automatic 3D non-rigid body registration system based upon the genetic algorithm (GA) process is presented. The system has been successfully applied to 2D and 3D situations using both rigid-body and affine transformations. Conventional optimization techniques and gradient search strategies generally require a good initial start location. The GA approach avoids the local minima/maxima traps of conventional optimization techniques. Based on the principles of Darwinian natural selection (survival of the fittest), the genetic algorithm has two basic steps: 1. Randomly generate an initial population. 2. Repeated application of the natural selection operation until a termination measure is satisfied. The natural selection process selects individuals based on their fitness to participate in the genetic operations; and it creates new individuals by inheritance from both parents, genetic recombination (crossover) and mutation. Once the termination criteria are satisfied, the optimum is selected from the population. The algorithm was applied on 2D and 3D magnetic resonance images (MRI). It does not require any preprocessing such as threshold, smoothing, segmentation, or definition of base points or edges. To evaluate the performance of the GA registration, the results were compared with results of the Automatic Image Registration technique (AIR) and manual registration which was used as the gold standard. Results showed that our GA implementation was a robust algorithm and gives very close results to the gold standard. A pre-cropping strategy was also discussed as an efficient preprocessing step to enhance the registration accuracy.

  8. Research on Joint Parameter Inversion for an Integrated Underground Displacement 3D Measuring Sensor

    PubMed Central

    Shentu, Nanying; Qiu, Guohua; Li, Qing; Tong, Renyuan; Shentu, Nankai; Wang, Yanjie

    2015-01-01

    Underground displacement monitoring is a key means to monitor and evaluate geological disasters and geotechnical projects. There exist few practical instruments able to monitor subsurface horizontal and vertical displacements simultaneously due to monitoring invisibility and complexity. A novel underground displacement 3D measuring sensor had been proposed in our previous studies, and great efforts have been taken in the basic theoretical research of underground displacement sensing and measuring characteristics by virtue of modeling, simulation and experiments. This paper presents an innovative underground displacement joint inversion method by mixing a specific forward modeling approach with an approximate optimization inversion procedure. It can realize a joint inversion of underground horizontal displacement and vertical displacement for the proposed 3D sensor. Comparative studies have been conducted between the measured and inversed parameters of underground horizontal and vertical displacements under a variety of experimental and inverse conditions. The results showed that when experimentally measured horizontal displacements and vertical displacements are both varied within 0 ~ 30 mm, horizontal displacement and vertical displacement inversion discrepancies are generally less than 3 mm and 1 mm, respectively, under three kinds of simulated underground displacement monitoring circumstances. This implies that our proposed underground displacement joint inversion method is robust and efficient to predict the measuring values of underground horizontal and vertical displacements for the proposed sensor. PMID:25871714

  9. Flow measurements in a model centrifugal pump by 3-D PIV

    NASA Astrophysics Data System (ADS)

    Yang, H.; Xu, H. R.; Liu, C.

    2012-11-01

    PIV (Particle Image Velocimetry), as an non-intrusive flow measurements technology, is widely used to investigate the flow fields in many areas. 3-D (three Dimensional) PIV has seldom been used to measure flow field in rotational impeller of centrifugal pump due to the difficulty of calibration in samll space. In this article, a specially manufactured water tank was used to perform the calibration for 3-D PIV measurement. The instantaneous absolute velocity in one impeller passage was obtained by merging of three sub zones and the relative velocity was acquired by velocity decomposition. The result shows that, when the pump runs at the condition of design flow rate, the radial component velocity Wr appears a concave distribution except the condition of R=45 mm. With the increase of radius, the circumference location of the minimum radial component velocity Wr moves from the pressure side to the suction side. At the same time, the tangential component velocity Wθ on the suction side decreases gradually with the increase of radius, while the component on the pressure side increases gradually. The secondary flow in different radius section has also been shown. At last, the error of PIV measurements was analyzed, which shows that the test results are accurate and the measured data is reliable.

  10. The image adaptive method for solder paste 3D measurement system

    NASA Astrophysics Data System (ADS)

    Xiaohui, Li; Changku, Sun; Peng, Wang

    2015-03-01

    The extensive application of Surface Mount Technology (SMT) requires various measurement methods to evaluate the circuit board. The solder paste 3D measurement system utilizing laser light projecting on the printed circuit board (PCB) surface is one of the critical methods. The local oversaturation, arising from the non-consistent reflectivity of the PCB surface, will lead to inaccurate measurement. The paper reports a novel optical image adaptive method of remedying the local oversaturation for solder paste measurement. The liquid crystal on silicon (LCoS) and image sensor (CCD or CMOS) are combined as the high dynamic range image (HDRI) acquisition system. The significant characteristic of the new method is that the image after adjustment is captured by specially designed HDRI acquisition system programmed by the LCoS mask. The formation of the LCoS mask, depending on a HDRI combined with the image fusion algorithm, is based on separating the laser light from the local oversaturated region. Experimental results demonstrate that the method can significantly improve the accuracy for the solder paste 3D measurement system with local oversaturation.

  11. Measurement Matrix Optimization and Mismatch Problem Compensation for DLSLA 3-D SAR Cross-Track Reconstruction.

    PubMed

    Bao, Qian; Jiang, Chenglong; Lin, Yun; Tan, Weixian; Wang, Zhirui; Hong, Wen

    2016-01-01

    With a short linear array configured in the cross-track direction, downward looking sparse linear array three-dimensional synthetic aperture radar (DLSLA 3-D SAR) can obtain the 3-D image of an imaging scene. To improve the cross-track resolution, sparse recovery methods have been investigated in recent years. In the compressive sensing (CS) framework, the reconstruction performance depends on the property of measurement matrix. This paper concerns the technique to optimize the measurement matrix and deal with the mismatch problem of measurement matrix caused by the off-grid scatterers. In the model of cross-track reconstruction, the measurement matrix is mainly affected by the configuration of antenna phase centers (APC), thus, two mutual coherence based criteria are proposed to optimize the configuration of APCs. On the other hand, to compensate the mismatch problem of the measurement matrix, the sparse Bayesian inference based method is introduced into the cross-track reconstruction by jointly estimate the scatterers and the off-grid error. Experiments demonstrate the performance of the proposed APCs' configuration schemes and the proposed cross-track reconstruction method. PMID:27556471

  12. Shape measurement and vibration analysis of moving speaker cone

    NASA Astrophysics Data System (ADS)

    Zhang, Qican; Liu, Yuankun; Lehtonen, Petri

    2014-06-01

    Surface three-dimensional (3-D) shape information is needed for many fast processes such as structural testing of material, standing waves on loudspeaker cone, etc. Usually measurement is done from limited number of points using electrical sensors or laser distance meters. Fourier Transform Profilometry (FTP) enables fast shape measurement of the whole surface. Method is based on angled sinusoidal fringe pattern projection and image capturing. FTP requires only one image of the deformed fringe pattern to restore the 3-D shape of the measured object, which makes real-time or dynamic data processing possible. In our experiment the method was used for loudspeaker cone distortion measurement in dynamic conditions. For sound quality issues it is important that the whole cone moves in same phase and there are no partial waves. Our imaging resolution was 1280x1024 pixels and frame rate was 200 fps. Using our setup we found unwanted spatial waves in our sample cone.

  13. Fusion and Visualization of HiRISE Super-Resolution, Shape-from-Shading DTM with MER Stereo 3D Reconstructions

    NASA Astrophysics Data System (ADS)

    Gupta, S.; Paar, G.; Muller, J. P.; Tao, Y.; Tyler, L.; Traxler, C.; Hesina, G.; Huber, B.; Nauschnegg, B.

    2014-12-01

    The FP7-SPACE project PRoViDE has assembled a major portion of the imaging data gathered so far from rover vehicles, landers and probes on extra-terrestrial planetary surfaces into a unique database, bringing them into a common planetary geospatial context and providing access to a complete set of 3D vision products. One major aim of PRoViDE is the fusion between orbiter and rover image products. To close the gap between HiRISE imaging resolution (down to 25cm for the OrthoRectified image (ORI), down to 1m for the DTM) and surface vision products, images from multiple HiRISE acquisitions are combined into a super resolution data set (Tao & Muller, 2014), increasing to 5cm resolution the Ortho images. Furthermore, shape-from-shading is applied to one of the ORIs at its original resolution for refinement of the HiRISE DTM, leading to DTM ground resolutions of up to 25 cm. After texture-based co-registration with these refined orbiter 3D products, MER PanCam and NavCam 3D image products can be smoothly pasted into a multi-resolution 3D data representation. Typical results from the MER mission are presented by a dedicated real-time rendering tool which is fed by a hierarchical 3D data structure that is able to cope with all involved scales from global planetary scale down to close-up reconstructions in the mm range. This allows us to explore and analyze the geological characteristics of rock outcrops, for example the detailed geometry and internal features of sedimentary rock layers, to aid paleoenvironmental interpretation. This integrated approach enables more efficient development of geological models of martian rock outcrops. The rendering tool also provides measurement tools to obtain geospatial data of surface points and distances between them. We report on novel scientific use cases and the added value potential of the resultant high-quality data set and presentation means to support further geologic investigations. The research leading to these results has

  14. Assessing the Potential of Low-Cost 3D Cameras for the Rapid Measurement of Plant Woody Structure

    PubMed Central

    Nock, Charles A; Taugourdeau, Olivier; Delagrange, Sylvain; Messier, Christian

    2013-01-01

    Detailed 3D plant architectural data have numerous applications in plant science, but many existing approaches for 3D data collection are time-consuming and/or require costly equipment. Recently, there has been rapid growth in the availability of low-cost, 3D cameras and related open source software applications. 3D cameras may provide measurements of key components of plant architecture such as stem diameters and lengths, however, few tests of 3D cameras for the measurement of plant architecture have been conducted. Here, we measured Salix branch segments ranging from 2–13 mm in diameter with an Asus Xtion camera to quantify the limits and accuracy of branch diameter measurement with a 3D camera. By scanning at a variety of distances we also quantified the effect of scanning distance. In addition, we also test the sensitivity of the program KinFu for continuous 3D object scanning and modeling as well as other similar software to accurately record stem diameters and capture plant form (<3 m in height). Given its ability to accurately capture the diameter of branches >6 mm, Asus Xtion may provide a novel method for the collection of 3D data on the branching architecture of woody plants. Improvements in camera measurement accuracy and available software are likely to further improve the utility of 3D cameras for plant sciences in the future. PMID:24287538

  15. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices.

    PubMed

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-01-01

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given. PMID:26703624

  16. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices

    PubMed Central

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-01-01

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given. PMID:26703624

  17. Mining 3D patterns from gene expression temporal data: a new tricluster evaluation measure.

    PubMed

    Gutiérrez-Avilés, David; Rubio-Escudero, Cristina

    2014-01-01

    Microarrays have revolutionized biotechnological research. The analysis of new data generated represents a computational challenge due to the characteristics of these data. Clustering techniques are applied to create groups of genes that exhibit a similar behavior. Biclustering emerges as a valuable tool for microarray data analysis since it relaxes the constraints for grouping, allowing genes to be evaluated only under a subset of the conditions. However, if a third dimension appears in the data, triclustering is the appropriate tool for the analysis. This occurs in longitudinal experiments in which the genes are evaluated under conditions at several time points. All clustering, biclustering, and triclustering techniques guide their search for solutions by a measure that evaluates the quality of clusters. We present an evaluation measure for triclusters called Mean Square Residue 3D. This measure is based on the classic biclustering measure Mean Square Residue. Mean Square Residue 3D has been applied to both synthetic and real data and it has proved to be capable of extracting groups of genes with homogeneous patterns in subsets of conditions and times, and these groups have shown a high correlation level and they are also related to their functional annotations extracted from the Gene Ontology project. PMID:25143987

  18. Mining 3D Patterns from Gene Expression Temporal Data: A New Tricluster Evaluation Measure

    PubMed Central

    2014-01-01

    Microarrays have revolutionized biotechnological research. The analysis of new data generated represents a computational challenge due to the characteristics of these data. Clustering techniques are applied to create groups of genes that exhibit a similar behavior. Biclustering emerges as a valuable tool for microarray data analysis since it relaxes the constraints for grouping, allowing genes to be evaluated only under a subset of the conditions. However, if a third dimension appears in the data, triclustering is the appropriate tool for the analysis. This occurs in longitudinal experiments in which the genes are evaluated under conditions at several time points. All clustering, biclustering, and triclustering techniques guide their search for solutions by a measure that evaluates the quality of clusters. We present an evaluation measure for triclusters called Mean Square Residue 3D. This measure is based on the classic biclustering measure Mean Square Residue. Mean Square Residue 3D has been applied to both synthetic and real data and it has proved to be capable of extracting groups of genes with homogeneous patterns in subsets of conditions and times, and these groups have shown a high correlation level and they are also related to their functional annotations extracted from the Gene Ontology project. PMID:25143987

  19. Comparison of 2D and 3D flame topography measured by planar laser-induced fluorescence and tomographic chemiluminescence.

    PubMed

    Ma, Lin; Wu, Yue; Xu, Wenjiang; Hammack, Stephen D; Lee, Tonghun; Carter, Campbell D

    2016-07-10

    The goal of this work was to contrast and compare the 2D and 3D flame topography of a turbulent flame. The 2D measurements were obtained using CH-based (methylidyne radical-based) planar laser-induced fluorescence (PLIF), and the 3D measurements were obtained through a tomographic chemiluminescence (TC) technique. Both PLIF and TC were performed simultaneously on a turbulent premixed Bunsen flame. The PLIF measurements were then compared to a cross section of the 3D TC measurements, both to provide a validation to the 3D measurements and also to illustrate the differences in flame structures inferred from the 2D and 3D measurements. PMID:27409304

  20. CAD/CAM/CAE representation of 3D objects measured by fringe projection

    NASA Astrophysics Data System (ADS)

    Pancewicz, Tomasz; Kujawinska, Malgorzata

    1998-07-01

    In the paper the creation of a virtual object on the base of optical measurement of 3D object by fringe projection technique coupled with the capabilities of CAD systems is presented. Basic stages of that task, being the most important part of the reverse engineering process, are discussed and the procedure is formulated by terms and definitions of theory of optimal algorithms. The quality criteria of a virtual object are defined and the influence of consecutive stages of the task on the quality of the virtual object is discussed.

  1. Dimensional measurement of 3D microstruture based on white light interferometer

    NASA Astrophysics Data System (ADS)

    Thian, S. C. H.; Feng, W.; Wong, Y. S.; Fuh, J. Y. H.; Loh, H. T.; Tee, K. H.; Tang, Y.; Lu, L.

    2007-07-01

    Dimensional metrology for micro/nano structure is crucial for addressing quality issues and understanding the performance of micro-fabricated products and micro-fabrication processes. Most of the established methods are based on optical microscopy for planar dimensions and stylus profilometry for out-of-plane dimensions. Contact profilers suffer from slow speed of measurement for three-dimensional profiles and are not suitable for delicate surfaces and parts. Advanced systems using white light interferometer are equipped with CCD cameras and interfaced with a microscope to conduct an array of measurements ranging from two-dimensional to three-dimensional profiles and surface roughness analysis. This paper presents a methodology based on white light interferometer for the dimensional measurement of 3D micro-structures, demonstrated on micro-gears and moulds produced by UV lithography and vacuum casting, respectively. Physical artifacts, such as gauge blocks, are also utilized to verify and validate the measurements on the microcomponents.

  2. Real-time multicamera system for measurement of 3D coordinates by pattern projection

    NASA Astrophysics Data System (ADS)

    Sainov, Ventseslav; Stoykova, Elena; Harizanova, Jana

    2007-06-01

    The report describes a real-time pattern-projection system for measurement of 3D coordinates with simultaneous illumination and recording of four phase-shifted fringe patterns which are projected at four different wavelengths and captured by four synchronized CCD cameras. This technical solution overcomes the main drawback of the temporal phase-shifting profilometry in which the pattern acquisition is made successively in time. The work considers the use of a sinusoidal phase grating as a projection element which is made by analysis of the frequency content of the projected fringes in the Fresnel diffraction zone and by test measurements of relative 3D coordinates that are performed with interferometrically recorded sinusoidal phase gratings on holographic plates. Finally, operation of a four-wavelength profilometric system with four spatially phase-shifted at π/2 sinusoidal phase gratings illuminated with four diode lasers at wavelengths 790 nm, 810 nm, 850 nm and 910 nm is simulated and the systematical error of the profilometric measurement is evaluated.

  3. Reproducibility of 3D kinematics and surface electromyography measurements of mastication.

    PubMed

    Remijn, Lianne; Groen, Brenda E; Speyer, Renée; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2016-03-01

    The aim of this study was to determine the measurement reproducibility for a procedure evaluating the mastication process and to estimate the smallest detectable differences of 3D kinematic and surface electromyography (sEMG) variables. Kinematics of mandible movements and sEMG activity of the masticatory muscles were obtained over two sessions with four conditions: two food textures (biscuit and bread) of two sizes (small and large). Twelve healthy adults (mean age 29.1 years) completed the study. The second to the fifth chewing cycle of 5 bites were used for analyses. The reproducibility per outcome variable was calculated with an intraclass correlation coefficient (ICC) and a Bland-Altman analysis was applied to determine the standard error of measurement relative error of measurement and smallest detectable differences of all variables. ICCs ranged from 0.71 to 0.98 for all outcome variables. The outcome variables consisted of four bite and fourteen chewing cycle variables. The relative standard error of measurement of the bite variables was up to 17.3% for 'time-to-swallow', 'time-to-transport' and 'number of chewing cycles', but ranged from 31.5% to 57.0% for 'change of chewing side'. The relative standard error of measurement ranged from 4.1% to 24.7% for chewing cycle variables and was smaller for kinematic variables than sEMG variables. In general, measurements obtained with 3D kinematics and sEMG are reproducible techniques to assess the mastication process. The duration of the chewing cycle and frequency of chewing were the best reproducible measurements. Change of chewing side could not be reproduced. The published measurement error and smallest detectable differences will aid the interpretation of the results of future clinical studies using the same study variables. PMID:26617403

  4. Measuring mandibular asymmetry in Class I normal subjects using 3D novel coordinate system

    PubMed Central

    Kheir, Nadia Abou; Kau, Chung How

    2014-01-01

    Introduction: Orthodontic treatment plays a major role in cosmetic dentistry. A harmonious facial balance is normally the end point in comprehensive orthodontic outcomes. In order to achieve this goal, correct diagnosis of asymmetry should be done starting from the outer facial morphology forms and progressively moving to the dental occlusion. The prime importance of measuring mandibular asymmetry is its tremendous effect on the occlusion. Objective: The aim of this study was to measure mandibular asymmetry in a cohort Class I molar relationship comparing right and left sides using new three-dimensions (3D) imaging technique with the aid of 3D software (in vivo 5.2.3 [San Jose, CA]). Materials and Methods: 35 DICOM files were initially collected retrospectively and seven were excluded due to (1) condylar resorption, (2) history of trauma and (3) unclear DICOM file. A new coordinate system was set for the mid-sagittal plane (MSP), Frankfort horizontal plane and frontal plane (FP). Each cone beam computed tomography (CBCT) was appraised using 16 evaluation criteria bilaterally. Five mandibular landmarks were selected: Condylion_R, Gonion_R, Menton, Gonion_L and Condylion_L. Using these points, the mandible was further divided into four parts: (1) Ramus length right side, body of the mandible right side, body of the Ramus left side and Ramus length left side. The angles between each line and the three different planes were acquired in order to compare each line from a 3D aspect. Mean and standard deviation were calculated for the 28 CBCTs. Results: Significant bilateral differences were reported in the angle between the ramus length and MSP and the ramus length and the FP (P < 0.05). Significant lateroanterior shift of the mandibular ramus on the left side in comparison with the right side. Conclusion: Viewing an object using three different angles between the four parts of the mandible and each plane is a valid method to replicate the actual object. PMID:24987596

  5. Angle-independent measure of motion for image-based gating in 3D coronary angiography

    SciTech Connect

    Lehmann, Glen C.; Holdsworth, David W.; Drangova, Maria

    2006-05-15

    The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2D angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period ({rho}) to R-waves (R) detected in the patient's ECG and found a mean difference of 14{+-}80 ms. Two simultaneous angular positions were acquired and {rho} was detected for each position. There was no statistically significant difference (P=0.79) between {rho} in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed the SIC

  6. Active shape models for a fully automated 3D segmentation of the liver--an evaluation on clinical data.

    PubMed

    Heimann, Tobias; Wolf, Ivo; Meinzer, Hans-Peter

    2006-01-01

    This paper presents an evaluation of the performance of a three-dimensional Active Shape Model (ASM) to segment the liver in 48 clinical CT scans. The employed shape model is built from 32 samples using an optimization approach based on the minimum description length (MDL). Three different gray-value appearance models (plain intensity, gradient and normalized gradient profiles) are created to guide the search. The employed segmentation techniques are ASM search with 10 and 30 modes of variation and a deformable model coupled to a shape model with 10 modes of variation. To assess the segmentation performance, the obtained results are compared to manual segmentations with four different measures (overlap, average distance, RMS distance and ratio of deviations larger 5mm). The only appearance model delivering usable results is the normalized gradient profile. The deformable model search achieves the best results, followed by the ASM search with 30 modes. Overall, statistical shape modeling delivers very promising results for a fully automated segmentation of the liver. PMID:17354754

  7. A new method using orthogonal two-frequency grating in online 3D measurement

    NASA Astrophysics Data System (ADS)

    Peng, Kuang; Cao, Yiping; Wu, Yingchun; Lu, Mingteng

    2016-09-01

    In online 3D measurement, a new method using orthogonal two-frequency grating based on Phase Measuring Profilometry(PMP) is proposed. The modulation of the entire measured object is used to match pixels and this proposed method successfully resolves the contradiction of the demand for different frequency fringes between the extraction of the modulation information and the phase unwrapping. The high-frequency fringe is used to catch the better modulation patterns for pixel matching, and the low-frequency fringe is used to calculate the phase distribution and avoid phase unwrapping error. In addition, to extract the better modulation patterns for pixel matching, the flat filtering window replaces the circular filtering window to avoid the spectrum aliasing phenomenon. The simulations and experiments show its feasibility.

  8. Registration of Feature-Poor 3D Measurements from Fringe Projection

    PubMed Central

    von Enzberg, Sebastian; Al-Hamadi, Ayoub; Ghoneim, Ahmed

    2016-01-01

    We propose a novel method for registration of partly overlapping three-dimensional surface measurements for stereo-based optical sensors using fringe projection. Based on two-dimensional texture matching, it allows global registration of surfaces with poor and ambiguous three-dimensional features, which are common to surface inspection applications. No prior information about relative sensor position is necessary, which makes our approach suitable for semi-automatic and manual measurement. The algorithm is robust and works with challenging measurements, including uneven illumination, surfaces with specular reflection as well as sparsely textured surfaces. We show that precisions of 1 mm and below can be achieved along the surfaces, which is necessary for further local 3D registration. PMID:26927106

  9. An experimental technique for performing 3-D LDA measurements inside whirling annular seals

    NASA Astrophysics Data System (ADS)

    Morrison, Gerald L.; Johnson, Mark C.; Deotte, Robert E., Jr.; Thames, H. Davis, III; Wiedner, Brian G.

    1992-09-01

    During the last several years, the Fluid Mechanics Division of the Turbomachinery Laboratory at Texas A&M University has developed a rather unique facility with the experimental capability for measuring the flow field inside journal bearings, labyrinth seals, and annular seals. The facility consists of a specially designed 3-D LDA system which is capable of measuring the instantaneous velocity vector within 0.2 mm of a wall while the laser beams are aligned almost perpendicular to the wall. This capability was required to measure the flow field inside journal bearings, labyrinth seals, and annular seals. A detailed description of this facility along with some representative results obtained for a whirling annular seal are presented.

  10. Registration of Feature-Poor 3D Measurements from Fringe Projection.

    PubMed

    von Enzberg, Sebastian; Al-Hamadi, Ayoub; Ghoneim, Ahmed

    2016-01-01

    We propose a novel method for registration of partly overlapping three-dimensional surface measurements for stereo-based optical sensors using fringe projection. Based on two-dimensional texture matching, it allows global registration of surfaces with poor and ambiguous three-dimensional features, which are common to surface inspection applications. No prior information about relative sensor position is necessary, which makes our approach suitable for semi-automatic and manual measurement. The algorithm is robust and works with challenging measurements, including uneven illumination, surfaces with specular reflection as well as sparsely textured surfaces. We show that precisions of 1 mm and below can be achieved along the surfaces, which is necessary for further local 3D registration. PMID:26927106

  11. Developing on-machine 3D profile measurement for deterministic fabrication of aspheric mirrors.

    PubMed

    Dong, Zhichao; Cheng, Haobo; Ye, Xu; Tam, Hon-Yuen

    2014-08-01

    Three-dimensional profile measurement is perceived as an indispensable process for deterministic fabrication of aspheric mirrors. In this work, we develop on-machine 3D profile measurement on a subaperture polishing machine, namely, JR-1800. The influences of mechanical errors, misalignments, output stability, temperature variation, and natural vibration are investigated in detail by calibration, mechanical alignment, and finite-element analysis. Two quantitative methods are presented for aligning the turntable, length gauge, and workpiece into together. An error compensation model is also developed for further eliminating misalignments. For feasibility validation, two prototypical workpieces are measured by JR-1800 and an interferometer. The results indicate that JR-1800 has an RMS repeatability of ~λ/30 (λ=632.8  nm). The data provided by the two systems are highly coincident. Direct subtractions of the results from the two systems indicate that the RMS deviations for both segments are less than 0.07 μm. PMID:25090332

  12. 3D printed miniaturized spectral system for tissue fluorescence lifetime measurements

    NASA Astrophysics Data System (ADS)

    Zou, Luwei; Mahmoud, Mohamad; Fahs, Mehdi; Liu, Rui; Lo, Joe F.

    2016-04-01

    Various types of collagens, e.g. type I and III, represent the main load-bearing components in biological tissues. Their composition changes during processes like wound healing and fibrosis. Collagens exhibit autofluorescence when excited by ultra-violet light, distinguishable by their unique fluorescent lifetimes across a range of emission wavelengths. Therefore, we designed a miniaturized spectral-lifetime detection system for collagens as a non-invasive probe for monitoring tissue in wound healing and scarring applications. A sine modulated LED illumination was applied to enable frequency domain (FD) fluorescence lifetime measurements under different wavelengths bands, separated via a series of longpass dichroics at 387nm, 409nm and 435nm. To achieve the minute scale of optomechanics, we employed a stereolithography based 3D printer with <50 μm resolution to create a custom designed optical mount in a hand-held form factor. We examined the characteristics of the 3D printed optical system with finite element modeling to simulate the effect of thermal (LED) and mechanical (handling) strain on the optical system. Using this device, the phase shift and demodulation of collagen types were measured, where the separate spectral bands enhanced the differentiation of their lifetimes.

  13. ALE3D Simulation and Measurement of Violence in a Fast Cookoff Experiment with LX-10

    SciTech Connect

    McClelland, M A; Maienschein, J L; Howard, W M; deHaven, M R

    2006-11-22

    We performed a computational and experimental analysis of fast cookoff of LX-10 (94.7% HMX, 5.3% Viton A) confined in a 2 kbar steel tube with reinforced end caps. A Scaled-Thermal-Explosion-eXperiment (STEX) was completed in which three radiant heaters were used to heat the vessel until ignition, resulting in a moderately violent explosion after 20.4 minutes. Thermocouple measurements showed tube temperatures as high as 340 C at ignition and LX-10 surface temperatures as high as 279 C, which is near the melting point of HMX. Three micro-power radar systems were used to measure mean fragment velocities of 840 m/s. Photonics Doppler Velocimeters (PDVs) showed a rapid acceleration of fragments over 80 {micro}s. A one-dimensional ALE3D cookoff model at the vessel midplane was used to simulate the heating, thermal expansion, LX-10 decomposition composition, and closing of the gap between the HE (High Explosive) and vessel wall. Although the ALE3D simulation terminated before ignition, the model provided a good representation of heat transfer through the case and across the dynamic gap to the explosive.

  14. Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms

    NASA Astrophysics Data System (ADS)

    Han, Tao; Lai, Chao-Jen; Chen, Lingyun; Liu, Xinming; Shen, Youtao; Zhong, Yuncheng; Ge, Shuaiping; Yi, Ying; Wang, Tianpeng; Yang, Wei T.; Shaw, Chris C.

    2009-02-01

    Breast density has been recognized as one of the major risk factors for breast cancer. However, breast density is currently estimated using mammograms which are intrinsically 2D in nature and cannot accurately represent the real breast anatomy. In this study, a novel technique for measuring breast density based on the segmentation of 3D cone beam CT (CBCT) images was developed and the results were compared to those obtained from 2D digital mammograms. 16 mastectomy breast specimens were imaged with a bench top flat-panel based CBCT system. The reconstructed 3D CT images were corrected for the cupping artifacts and then filtered to reduce the noise level, followed by using threshold-based segmentation to separate the dense tissue from the adipose tissue. For each breast specimen, volumes of the dense tissue structures and the entire breast were computed and used to calculate the volumetric breast density. BI-RADS categories were derived from the measured breast densities and compared with those estimated from conventional digital mammograms. The results show that in 10 of 16 cases the BI-RADS categories derived from the CBCT images were lower than those derived from the mammograms by one category. Thus, breasts considered as dense in mammographic examinations may not be considered as dense with the CBCT images. This result indicates that the relation between breast cancer risk and true (volumetric) breast density needs to be further investigated.

  15. 3D face recognition using simulated annealing and the surface interpenetration measure.

    PubMed

    Queirolo, Chauã C; Silva, Luciano; Bellon, Olga R P; Segundo, Maurício Pamplona

    2010-02-01

    This paper presents a novel automatic framework to perform 3D face recognition. The proposed method uses a Simulated Annealing-based approach (SA) for range image registration with the Surface Interpenetration Measure (SIM), as similarity measure, in order to match two face images. The authentication score is obtained by combining the SIM values corresponding to the matching of four different face regions: circular and elliptical areas around the nose, forehead, and the entire face region. Then, a modified SA approach is proposed taking advantage of invariant face regions to better handle facial expressions. Comprehensive experiments were performed on the FRGC v2 database, the largest available database of 3D face images composed of 4,007 images with different facial expressions. The experiments simulated both verification and identification systems and the results compared to those reported by state-of-the-art works. By using all of the images in the database, a verification rate of 96.5 percent was achieved at a False Acceptance Rate (FAR) of 0.1 percent. In the identification scenario, a rank-one accuracy of 98.4 percent was achieved. To the best of our knowledge, this is the highest rank-one score ever achieved for the FRGC v2 database when compared to results published in the literature. PMID:20075453

  16. 3D Canonical Momentum Measurements During the Merging of Two Counter-Helicity Spheromaks

    NASA Astrophysics Data System (ADS)

    You, Setthivoine; Balandin, Alexander; Tanabe, Hiroshi; Ono, Yasushi

    2009-11-01

    A pair of counter-helicity spheromaks can merge in two possible ways to form a single final compact toroid depending on their toroidal magnetic field direction. Magnetohydrodynamically, no difference should be expected but experimentally, a positive/negative merging or negative/positive merging will generate final compact toroids with different lifetimes and sizes. A pair of multichannel spectroscopic diagnostics have been installed on the TS-4 experiment with view chords designed for measuring 3D ion velocities and temperature. One set retrieves toroidal velocities and temperature from conventional Abel inversion. The second, novel arrangement retrieves poloidal velocities from 3D vector tomography reconstruction and temperature from scalar tomography. With in situ magnetic probe arrays, the ion canonical momentum is thus determined in the complete volume. The ion temperature at the reconnection plane is also evaluated [1]. Both sets of measurements are followed over several repeatable shots during the spheromak merging to also track the evolution of ion self-helicity.[0pt][1] Tanabe, You, Balandin, Ono, poster this meeting.

  17. Measuring the 3-D wind vector with a weight-shift microlight aircraft

    NASA Astrophysics Data System (ADS)

    Metzger, S.; Junkermann, W.; Butterbach-Bahl, K.; Schmid, H. P.; Foken, T.

    2011-02-01

    This study investigates whether the 3-D wind vector can be measured reliably from a highly transportable and low-cost weight-shift microlight aircraft. Therefore we draw up a transferable procedure to accommodate flow distortion originating from the aircraft body and -wing. This procedure consists of the analysis of aircraft dynamics and seven successive calibration steps. For our aircraft the horizontal wind components receive their greatest single amendment (14%, relative to the initial uncertainty) from the correction of flow distortion magnitude in the dynamic pressure computation. Conversely the vertical wind component is most of all improved (31%) by subsequent steps considering the 3-D flow distortion distribution in the flow angle computations. Therein the influences of the aircraft's aeroelastic wing (53%), as well as sudden changes in wing loading (16%) are considered by using the measured lift coefficient as explanatory variable. Three independent lines of analysis are used to evaluate the quality of the wind measurement: (a) A wind tunnel study in combination with the propagation of sensor uncertainties defines the systems input uncertainty to ≈0.6 m s-1 at the extremes of a 95% confidence interval. (b) During severe vertical flight manoeuvres the deviation range of the vertical wind component does not exceed 0.3 m s-1. (c) The comparison with ground based wind measurements yields an overall operational uncertainty (root mean square deviation) of ≈0.4 m s-1 for the horizontal and ≍0.3 m s-1 for the vertical wind components. No conclusive dependence of the uncertainty on the wind magnitude (<8 m s-1) or true airspeed (ranging from 23-30 m s-1) is found. Hence our analysis provides the necessary basis to study the wind measurement precision and spectral quality, which is prerequisite for reliable eddy-covariance flux measurements.

  18. Measuring the 3-D wind vector with a weight-shift microlight aircraft

    NASA Astrophysics Data System (ADS)

    Metzger, S.; Junkermann, W.; Butterbach-Bahl, K.; Schmid, H. P.; Foken, T.

    2011-07-01

    This study investigates whether the 3-D wind vector can be measured reliably from a highly transportable and low-cost weight-shift microlight aircraft. Therefore we draw up a transferable procedure to accommodate flow distortion originating from the aircraft body and -wing. This procedure consists of the analysis of aircraft dynamics and seven successive calibration steps. For our aircraft the horizontal wind components receive their greatest single amendment (14 %, relative to the initial uncertainty) from the correction of flow distortion magnitude in the dynamic pressure computation. Conversely the vertical wind component is most of all improved (31 %) by subsequent steps considering the 3-D flow distortion distribution in the flow angle computations. Therein the influences of the aircraft's trim (53 %), as well as changes in the aircraft lift (16 %) are considered by using the measured lift coefficient as explanatory variable. Three independent lines of analysis are used to evaluate the quality of the wind measurement: (a) A wind tunnel study in combination with the propagation of sensor uncertainties defines the systems input uncertainty to ≈0.6 m s-1 at the extremes of a 95 % confidence interval. (b) During severe vertical flight manoeuvres the deviation range of the vertical wind component does not exceed 0.3 m s-1. (c) The comparison with ground based wind measurements yields an overall operational uncertainty (root mean square error) of ≈0.4 m s-1 for the horizontal and ≈0.3 m s-1 for the vertical wind components. No conclusive dependence of the uncertainty on the wind magnitude (<8 m s-1) or true airspeed (ranging from 23-30 m s-1) is found. Hence our analysis provides the necessary basis to study the wind measurement precision and spectral quality, which is prerequisite for reliable Eddy-Covariance flux measurements.

  19. Simultaneous, accurate measurement of the 3D position and orientation of single molecules

    PubMed Central

    Backlund, Mikael P.; Lew, Matthew D.; Backer, Adam S.; Sahl, Steffen J.; Grover, Ginni; Agrawal, Anurag; Piestun, Rafael; Moerner, W. E.

    2012-01-01

    Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule’s 3D orientation and z position. Failure to account for this fact can lead to significant lateral (x, y) mislocalizations (up to ∼50–200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from ∼2× worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (∼4× worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit). PMID:23129640

  20. Review and comparison of temporal- and spatial-phase shift speckle pattern interferometry for 3D deformation measurement

    NASA Astrophysics Data System (ADS)

    Xie, Xin; Yang, Lianxiang; Chen, Xu; Xu, Nan; Wang, Yonghong

    2013-10-01

    High accuracy full field three dimensional (3D) deformation measurements have always been an essential problem for the manufacturing, instrument, and aerospace industry. 3D deformations, which can be translated further into 3D strain and stress, are the key parameter for design, manufacturing and quality control. Due to the fast development of the manufacturing industry, especially in the automobile and airspace industry, rapid design and optimization concepts have already widely accepted. These concepts all require the support of rapid, high sensitive and accuracy 3D deformation measurement. Advanced optical methods are gaining widely acceptance for deformation and stain measurement by industry due to the advantages of non-contact, full-field and high measurement sensitivity. Of these methods, Electronic Speckle Pattern Interferometry (ESPI) is the most sensitive and accurate method for 3D deformation measurement in micro and sub micro-level. ESPI measures deformation by evaluating the phase difference of two recorded speckle interferograms under different loading conditions. Combined with a phase shift technique, ESPI systems can measure the 3D deformation with dozens of nanometer level sensitivity. Cataloged by phase calculation methods, ESPI systems can be divided into temporal phase shift ESPI systems and spatial phase shift ESPI system. This article provides a review and a comparison of temporal and spatial phase shift speckle pattern interferometry for 3D deformation measurement. After an overview of the fundamentals of ESPI theory, temporal phase-shift and spatial phase-shift techniques, 3D deformation measurements by the temporal phase-shift ESPI which is suited well for static measurement and by the spatial phase-shift ESPI which is particularly useful for dynamic measurement will be discussed in detail. Basic theory, brief derivation and different optical layouts for the two systems will be presented. The potentials and limitations of the both ESPI

  1. Computerized method for automated measurement of thickness of cerebral cortex for 3-D MR images

    NASA Astrophysics Data System (ADS)

    Arimura, Hidetaka; Yoshiura, Takashi; Kumazawa, Seiji; Koga, Hiroshi; Sakai, Shuji; Mihara, Futoshi; Honda, Hiroshi; Ohki, Masafumi; Toyofuku, Fukai; Higashida, Yoshiharu

    2006-03-01

    Alzheimer's disease (AD) is associated with the degeneration of cerebral cortex, which results in focal volume change or thinning in the cerebral cortex in magnetic resonance imaging (MRI). Therefore, the measurement of the cortical thickness is important for detection of the atrophy related to AD. Our purpose was to develop a computerized method for automated measurement of the cortical thickness for three-dimensional (3-D) MRI. The cortical thickness was measured with normal vectors from white matter surface to cortical gray matter surface on a voxel-by-voxel basis. First, a head region was segmented by use of an automatic thresholding technique, and then the head region was separated into the cranium region and brain region by means of a multiple gray level thresholding with monitoring the ratio of the first maximum volume to the second one. Next, a fine white matter region was determined based on a level set method as a seed region of the rough white matter region extracted from the brain region. Finally, the cortical thickness was measured by extending normal vectors from the white matter surface to gray matter surface (brain surface) on a voxel-by-voxel basis. We applied the computerized method to high-resolution 3-D T1-weighted images of the whole brains from 7 clinically diagnosed AD patients and 8 healthy subjects. The average cortical thicknesses in the upper slices for AD patients were thinner than those for non-AD subjects, whereas the average cortical thicknesses in the lower slices for most AD patients were slightly thinner. Our preliminary results suggest that the MRI-based computerized measurement of gray matter atrophy is promising for detecting AD.

  2. 3D modeling of the molten zone shape created by an asymmetric HF EM field during the FZ crystal growth process

    NASA Astrophysics Data System (ADS)

    Rudevics, A.; Muiznieks, A.; Ratnieks, G.; Riemann, H.

    2005-06-01

    In the modern industrial floating zone (FZ) silicon crystal growth process by the needle-eye technique, the high frequency (HF) electromagnetic (EM) field plays a crucial role. The EM field melts a rotating poly silicon feed rod and maintains the zone of molten silicon, which is held by the rotating single crystal. To model such a system, the 2D axi-symmetric models can be used, however, due to the system's asymmetry (e.g., the asymmetry of the HF inductor) the applicability of such models is restricted. Therefore, the modeling of FZ process in three dimensions (3D) is necessary. This paper describes a new complex 3D mathematical model of the FZ crystal growth and a correspondingly developed software package Shape3D. A 3D calculation example for the realistic FZ system is also presented. Figs 25, Refs 9.

  3. Uncertainty studies of topographical measurements on steel surface corrosion by 3D scanning electron microscopy.

    PubMed

    Kang, K W; Pereda, M D; Canafoglia, M E; Bilmes, P; Llorente, C; Bonetto, R

    2012-02-01

    Pitting corrosion is a damage mechanism quite serious and dangerous in both carbon steel boiler tubes for power plants which are vital to most industries and stainless steels for orthopedic human implants whose demand, due to the increase of life expectation and rate of traffic accidents, has sharply increased. Reliable methods to characterize this kind of damage are becoming increasingly necessary, when trying to evaluate the advance of damage and to establish the best procedures for component inspection in order to determine remaining lives and failure mitigation. A study about the uncertainties on the topographies of corrosion pits from 3D SEM images, obtained at low magnifications (where errors are greater) and different stage tilt angles were carried out using an in-house software previously developed. Additionally, measurements of pit depths on biomaterial surfaces, subjected to two different surface treatments on stainless steels, were carried out. The different depth distributions observed were in agreement with electrochemical measurements. PMID:22051087

  4. 3D-DIP-Chip: a microarray-based method to measure genomic DNA damage

    PubMed Central

    Powell, James Rees; Bennett, Mark Richard; Evans, Katie Ellen; Yu, Shirong; Webster, Richard Michael; Waters, Raymond; Skinner, Nigel; Reed, Simon Huw

    2015-01-01

    Genotoxins cause DNA damage, which can result in genomic instability. The genetic changes induced have far-reaching consequences, often leading to diseases such as cancer. A wide range of genotoxins exists, including radiations and chemicals found naturally in the environment, and in man-made forms created by human activity across a variety of industries. Genomic technologies offer the possibility of unravelling the mechanisms of genotoxicity, including the repair of genetic damage, enhancing our ability to develop, test and safely use existing and novel materials. We have developed 3D-DIP-Chip, a microarray-based method to measure the prevalence of genomic genotoxin-induced DNA damage. We demonstrate the measurement of both physical and chemical induced DNA damage spectra, integrating the analysis of these with the associated changes in histone acetylation induced in the epigenome. We discuss the application of the method in the context of basic and translational sciences. PMID:25609656

  5. 3D printing of tissue-simulating phantoms as a traceable standard for biomedical optical measurement

    NASA Astrophysics Data System (ADS)

    Dong, Erbao; Wang, Minjie; Shen, Shuwei; Han, Yilin; Wu, Qiang; Xu, Ronald

    2016-01-01

    Optical phantoms are commonly used to validate and calibrate biomedical optical devices in order to ensure accurate measurement of optical properties in biological tissue. However, commonly used optical phantoms are based on homogenous materials that reflect neither optical properties nor multi-layer heterogeneities of biological tissue. Using these phantoms for optical calibration may result in significant bias in biological measurement. We propose to characterize and fabricate tissue simulating phantoms that simulate not only the multi-layer heterogeneities but also optical properties of biological tissue. The tissue characterization module detects tissue structural and functional properties in vivo. The phantom printing module generates 3D tissue structures at different scales by layer-by-layer deposition of phantom materials with different optical properties. The ultimate goal is to fabricate multi-layer tissue simulating phantoms as a traceable standard for optimal calibration of biomedical optical spectral devices.

  6. Calibration algorithm in robotic remanufacturing measurement system based on 3D laser scanner

    NASA Astrophysics Data System (ADS)

    Shen, C. D.; Zhu, S.; Li, C.; Liang, Y. Y.

    2009-07-01

    In robotic remanufacturing measurement system, the 3D laser scanner is arranged by the robot and the object scanned is mounted on a turntable. This paper deals with the algorithm of calibrating the relationship between the scanner coordinate and the robot Tool0, and furthermore locating the center axis of the turntable. The data of Tool0 can be directly obtained denoting its relationship with the robot base coordinate. So, the coordinate transformation problems are effectively solved and the measuring data which relative to the robot base coordinate could be congruously saved. This paper detailed explains the basic algorithm theory, computing method and the result data analysis, and etc. The calibration algorithm is deduced under the orthogonal coordinate.

  7. Study of the 3D geometry of tangential discontinuities based on simultaneous STEREO and Ulysses measurements

    NASA Astrophysics Data System (ADS)

    Facsko, Gabor; Reshetnyk, Volodymyr; Agapitov, Oleksiy; Opitz, Andrea; Szabo, Adam; McComas, David

    Tangential discontinuties (TDs) are usually considered as thin planar current sheets frozen in the solar wind flow. Previous studies based on the magnetic field measurements onboard of ACE, Wind, and STEREO A, and B proved that this hypotesis is not valid. The curvature of the TDs were determined in several cases. After applying minimum variance and the cross product methods for Ulysses, ACE and STEREO A and B magnetometer measurements, numerous TDs are identified in 2008 and 2009. The time shift of the TD observations is determinated by correlation analysis of the solar wind speed and the magnetic field variations. The 3D topology of the TD is then determinated in some special cases when the four spacecraft are on the same side of the Sun. After fitting a simple model, the location of the TD formation region can be outlined.

  8. Measurement of the photoionization cross section from the laser-populated 3D metastable levels in barium

    NASA Technical Reports Server (NTRS)

    Carlsten, J. L.; Mcilrath, T. J.; Parkinson, W. H.

    1974-01-01

    Measurements of the absolute photoionization cross section from the 6s5d 3D metastable level of barium are presented. The 3D levels were selectively populated with a high-power tuneable dye laser. The number density was determined by observing the resulting depopulation of the ground state when pumping occurred.

  9. Measuring the impact of 3D data geometric modeling on spatial analysis: Illustration with Skyview factor

    NASA Astrophysics Data System (ADS)

    Brasebin, M.; Perret, J.; Mustière, S.; Weber, C.

    2012-10-01

    The increased availability of 3D urban data reflects a growing interest in 3D spatial analysis. As 3D spatial analysis often uses complex 3D data, studies of the potential gains of using more detailed 3D urban databases for specific uses is an important issue. First, more complex data implies an increase in time and memory usage for the analysis (and calls for more research on the efficiency of the algorithms used). Second, detailed 3D urban data are complex to produce, expensive and it is important to be well informed in order to decide whether of not to invest in such data. Currently, many studies have been led about the fitness for use of 2D data but they are very scarce concerning 3D data. This article presents a method to determine the influence of 3D modeling on the results of 3D analysis by isolating the potential sources of errors (such as roof modeling and geometric accuracy). This method is applied on two 3D datasets (LOD1 and LOD2) and a 3D indicator (the sky view factor or SVF). The results show that the significant influence of roof modeling is globally compensated by the difference in geometric modeling but that important local variations are noticed. Nevertheless, for 75% of the SVF processed the difference between the results using these two databases is lower than 2%.

  10. 3D-ANTLERS: Virtual Reconstruction and Three-Dimensional Measurement

    NASA Astrophysics Data System (ADS)

    Barba, S.; Fiorillo, F.; De Feo, E.

    2013-02-01

    The main objective of this paper is to establish a procedural method for measuring and cataloguing antlers through the use of laser scanner and of a 3D reconstruction of complex modeling. The deer's antlers have been used as a test and subjected to capture and measurement. For this purpose multiple data sources techniques have been studied and compared, (also considering low-cost sensors) estimating the accuracy and its errors in order to demonstrate the validity of the process. A further development is the comparison of results with applications of digital photogrammetry, considering also cloud computing software. The study has began with an introduction to sensors, addressing the underlying characteristics of the technology available, the scope and the limits of these applications. We have focused particularly on the "structured light", as the acquisition will be completed through three-dimensional scanners: DAVID and the ARTEC MH. The first is a low-cost sensor, a basic webcam and a linear laser pointer, red coloured, that leads to acquisition of three-dimensional strips. The other one is a hand scanner; even in this case we will explain how to represent a 3D model, with a pipeline that provides data export from the "proprietary" to a "reverse engineering" software. Typically, these are the common steps to the two approaches that have been performed in WRAP format: point sampling, manual and global registration, repair normals, surface editing and texture projection. In fact, after a first and common data processing was done with the use of a software supplied with the equipment, the proto-models thus obtained were treated in Geomagic Studio, which was also chosen to allow the homogenization and standardization of data in order to make a more objective comparison. It is commonplace to observe that the editing of the digital mock-up obtained with the DAVID - which had not yet been upgraded to the 3.5 release at the time of this study - is substantially different

  11. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    SciTech Connect

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas; Aldén, Marcus; Li, Zhongshan E-mail: alpers@ma.tum.de; Moseev, Dmitry; Kusano, Yukihiro; Salewski, Mirko; Alpers, Andreas E-mail: alpers@ma.tum.de; Gritzmann, Peter; Schwenk, Martin

    2015-01-26

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

  12. Characterization of emissions from a desktop 3D printer and indoor air measurements in office settings.

    PubMed

    Steinle, Patrick

    2016-01-01

    Emissions from a desktop 3D printer based on fused deposition modeling (FDM) technology were measured in a test chamber and indoor air was monitored in office settings. Ultrafine aerosol (UFA) emissions were higher while printing a standard object with polylactic acid (PLA) than with acrylonitrile butadiene styrene (ABS) polymer (2.1 × 10(9) vs. 2.4 × 10(8) particles/min). Prolonged use of the printer led to higher emission rates (factor 2 with PLA and 4 with ABS, measured after seven months of occasional use). UFA consisted mainly of volatile droplets, and some small (100-300 nm diameter) iron containing and soot-like particles were found. Emissions of inhalable and respirable dust were below the limit of detection (LOD) when measured gravimetrically, and only slightly higher than background when measured with an aerosol spectrometer. Emissions of volatile organic compounds (VOC) were in the range of 10 µg/min. Styrene accounted for more than 50% of total VOC emitted when printing with ABS; for PLA, methyl methacrylate (MMA, 37% of TVOC) was detected as the predominant compound. Two polycyclic aromatic hydrocarbons (PAH), fluoranthene and pyrene, were observed in very low amounts. All other analyzed PAH, as well as inorganic gases and metal emissions except iron (Fe) and zinc (Zn), were below the LOD or did not differ from background without printing. A single 3D print (165 min) in a large, well-ventilated office did not significantly increase the UFA and VOC concentrations, whereas these were readily detectable in a small, unventilated room, with UFA concentrations increasing by 2,000 particles/cm(3) and MMA reaching a peak of 21 µg/m(3) and still being detectable in the room even 20 hr after printing. PMID:26550911

  13. A dual 3D DIC-system application for DSL strain and displacement measurements

    NASA Astrophysics Data System (ADS)

    Raurova, I.; Berggreen, C.; Eriksen, R.

    2010-06-01

    This paper describes a dual 3D Digital Image Correlation (DIC) system application for DLS strain and displacement measurements, where two 3D DIC-systems are used in parallel. The bonded specimens were tested to failure under monotonic loading in a uni-axial tensile testing machine at ambient temperature. Both surface inplane strain and full-field displacement values were recorded using two DIC systems: high speed (HS) and high resolution (HR). The HS system was used in a parallel setup with the HR system in order to detect the initial failure location and crack propagation rate during the brittle failure mechanism, where an interface crack is propagating between the straps and the inner adherent. Using two inherently different DIC systems involve a number of problems. This involves synchronization of the HS and HR systems, a common illumination level and speckle pattern. This paper therefore describes guidelines for a mutual system setup, applied in an experimental study of steel/epoxy DLS joints under pure tension.

  14. Error analysis in stereo vision for location measurement of 3D point

    NASA Astrophysics Data System (ADS)

    Li, Yunting; Zhang, Jun; Tian, Jinwen

    2015-12-01

    Location measurement of 3D point in stereo vision is subjected to different sources of uncertainty that propagate to the final result. For current methods of error analysis, most of them are based on ideal intersection model to calculate the uncertainty region of point location via intersecting two fields of view of pixel that may produce loose bounds. Besides, only a few of sources of error such as pixel error or camera position are taken into account in the process of analysis. In this paper we present a straightforward and available method to estimate the location error that is taken most of source of error into account. We summed up and simplified all the input errors to five parameters by rotation transformation. Then we use the fast algorithm of midpoint method to deduce the mathematical relationships between target point and the parameters. Thus, the expectations and covariance matrix of 3D point location would be obtained, which can constitute the uncertainty region of point location. Afterwards, we turned back to the error propagation of the primitive input errors in the stereo system and throughout the whole analysis process from primitive input errors to localization error. Our method has the same level of computational complexity as the state-of-the-art method. Finally, extensive experiments are performed to verify the performance of our methods.

  15. Measurements of stress fields near a grain boundary: Exploring blocked arrays of dislocations in 3D

    DOE PAGESBeta

    Guo, Y.; Collins, D. M.; Tarleton, E.; Hofmann, F.; Tischler, J.; Liu, W.; Xu, R.; Wilkinson, A. J.; Britton, T. B.

    2015-06-24

    The interaction between dislocation pile-ups and grain boundaries gives rise to heterogeneous stress distributions when a structural metal is subjected to mechanical loading. Such stress heterogeneity leads to preferential sites for damage nucleation and therefore is intrinsically linked to the strength and ductility of polycrystalline metals. To date the majority of conclusions have been drawn from 2D experimental investigations at the sample surface, allowing only incomplete observations. Our purpose here is to significantly advance the understanding of such problems by providing quantitative measurements of the effects of dislocation pile up and grain boundary interactions in 3D. This is accomplished throughmore » the application of differential aperture X-ray Laue micro-diffraction (DAXM) and high angular resolution electron backscatter diffraction (HR-EBSD) techniques. Our analysis demonstrates a similar strain characterization capability between DAXM and HR-EBSD and the variation of stress intensity in 3D reveals that different parts of the same grain boundary may have different strengths in resisting slip transfer, likely due to the local grain boundary curvature.« less

  16. Measurements of stress fields near a grain boundary: Exploring blocked arrays of dislocations in 3D

    SciTech Connect

    Guo, Y.; Collins, D. M.; Tarleton, E.; Hofmann, F.; Tischler, J.; Liu, W.; Xu, R.; Wilkinson, A. J.; Britton, T. B.

    2015-06-24

    The interaction between dislocation pile-ups and grain boundaries gives rise to heterogeneous stress distributions when a structural metal is subjected to mechanical loading. Such stress heterogeneity leads to preferential sites for damage nucleation and therefore is intrinsically linked to the strength and ductility of polycrystalline metals. To date the majority of conclusions have been drawn from 2D experimental investigations at the sample surface, allowing only incomplete observations. Our purpose here is to significantly advance the understanding of such problems by providing quantitative measurements of the effects of dislocation pile up and grain boundary interactions in 3D. This is accomplished through the application of differential aperture X-ray Laue micro-diffraction (DAXM) and high angular resolution electron backscatter diffraction (HR-EBSD) techniques. Our analysis demonstrates a similar strain characterization capability between DAXM and HR-EBSD and the variation of stress intensity in 3D reveals that different parts of the same grain boundary may have different strengths in resisting slip transfer, likely due to the local grain boundary curvature.

  17. Self-calibrating 360-degree shape measurement systems

    NASA Astrophysics Data System (ADS)

    Notni, Gunther; Kuehmstedt, Peter; Heinze, Matthias; Notni, Georg H.; Brakhage, Peter

    2001-10-01

    For measuring the 3D shape of complex objects by optical methods the optical sensor or the object have to be moved into multiple, overlapping measuring positions so as to view the entire surface. The resulting point clouds taken from the different views then have to be merged into a common coordinate system to obtain the final complete 3D view. Here we propose concepts of 3D-measurement arrangements using structured-light illumination with a digital-light projection unit to obtain a full-body view within a self- calibrating measurement strategy, whereas the necessary merging of the single views takes place fully automatically and done without any marker on the object surface, objects features, other merging procedure or high accurate object/sensor handling system. On the basis of this strategy different mobile and stationary arrangements are proposed and realized. A first integration in an industrial process will be presented showing the power of this concept by measuring the complete 3D shape of automotive parts and design objects within volume of 1dm3 up to 1m3. The measurements with this system showed a coordinate measurement accuracy of up to 10-5 of the field size.

  18. A new 3-D open-framework cadmium borovanadate with plane-shaped channels and high catalytic activity for the oxidation of cyclohexanol.

    PubMed

    Feng, Yuquan; Qiu, Dongfang; Fan, Huitao; Li, Min; Huang, Qunzeng; Shi, Hengzhen

    2015-05-21

    A new 3-D open-framework cadmium borovanadate with 6-connected topology was hydrothermally obtained and structurally characterized. It not only features new cadmium(II) borovanadate which possesses an open-framework structure with unique plane-shaped channels, but also exhibits interesting absorption properties and high catalytic activities for the oxidation of cyclohexanol. PMID:25882921

  19. Coupling the 3D hydro-morphodynamic model Telemac-3D-sisyphe and seismic measurements to estimate bedload transport rates in a small gravel-bed river.

    NASA Astrophysics Data System (ADS)

    Hostache, Renaud; Krein, Andreas; Barrière, Julien

    2014-05-01

    Coupling the 3D hydro-morphodynamic model Telemac-3D-sisyphe and seismic measurements to estimate bedload transport rates in a small gravel-bed river. Renaud Hostache, Andreas Krein, Julien Barrière During flood events, amounts of river bed material are transported via bedload. This causes problems, like the silting of reservoirs or the disturbance of biological habitats. Some current bedload measuring techniques have limited possibilities for studies in high temporal resolutions. Optical systems are usually not applicable because of high turbidity due to concentrated suspended sediment transported. Sediment traps or bedload samplers yield only summative information on bedload transport with low temporal resolution. An alternative bedload measuring technique is the use of seismological systems installed next to the rivers. The potential advantages are observations in real time and under undisturbed conditions. The study area is a 120 m long reach of River Colpach (21.5 km2), a small gravel bed river in Northern Luxembourg. A combined approach of hydro-climatological observations, hydraulic measurements, sediment sampling, and seismological measurements is used in order to investigate bedload transport phenomena. Information derived from seismic measurements and results from a 3-dimensional hydro-morphodynamic model are exemplarily discussed for a November 2013 flood event. The 3-dimensional hydro-morphodynamic model is based on the Telemac hydroinformatic system. This allows for dynamically coupling a 3D hydrodynamic model (Telemac-3D) and a morphodynamic model (Sisyphe). The coupling is dynamic as these models exchange their information during simulations. This is a main advantage as it allows for taking into account the effects of the morphologic changes of the riverbed on the water hydrodynamic and the bedload processes. The coupled model has been calibrated using time series of gauged water depths and time series of bed material collected sequentially (after

  20. Distributed microscopy: toward a 3D computer-graphic-based multiuser microscopic manipulation, imaging, and measurement system

    NASA Astrophysics Data System (ADS)

    Sulzmann, Armin; Carlier, Jerome; Jacot, Jacques

    1996-10-01

    The aim of this project is to telecontrol the movements in 3D-space of a microscope in order to manipulate and measure microsystems or micro parts aided by multi-user virtual reality (VR) environments. Presently microsystems are gaining in interest. Microsystems are small, independent modules, incorporating various functions, such as electronic, micro mechanical, data processing, optical, chemical, medical and biological functions. Though improving the manufacturing technologies, the measurement of the small structures to insure the quality of the process is a key information for the development. So far to measure the micro structures strong microscopes are needed. The use of highly magnifying computerized microscopes is expensive. To insure high quality measurements and distribute the acquired information to multi-user our proposed system is divided into three parts: the virtual reality microscopic environment (VRME)-based user-interface on a SGI workstation to prepare the manipulations and measurements. Secondly the computerized light microscope with the vision system inspecting the scene and getting the images of the specimen. Newly developed vision algorithms are used to analyze micro structures in the scene corresponding to the known a priori model. This vision is extracting position and shape of the objects and then transmitted as feedback to the user of the VRME-system to update his virtual environment. The internet demon is the third part of the system and distributes the information about the position of the micro structures, their shape and the images to the connected users who themselves may interact with the microscope (turn and displace the specimen on the back of a moving platform, or adding their structures to the scene and compare). The key idea behind our project VRME is to use the intuitiveness and the 3D visualization of VR environments coupled with a vision system to perform measurements of micro structures at a high accuracy. The direct

  1. The static accuracy and calibration of inertial measurement units for 3D orientation.

    PubMed

    Brodie, M A; Walmsley, A; Page, W

    2008-12-01

    Inertial measurement units (IMUs) are integrated electronic devices that contain accelerometers, magnetometers and gyroscopes. Wearable motion capture systems based on IMUs have been advertised as alternatives to optical motion capture. In this paper, the accuracy of five different IMUs of the same type in measuring 3D orientation in static situations, as well as the calibration of the accelerometers and magnetometers within the IMUs, has been investigated. The maximum absolute static orientation error was 5.2 degrees , higher than the 1 degrees claimed by the vendor. If the IMUs are re-calibrated at the time of measurement with the re-calibration procedure described in this paper, it is possible to obtain an error of less than 1 degrees , in agreement with the vendor's specifications (XSens Technologies B.V. 2005. Motion tracker technical documentation Mtx-B. Version 1.03. Available from: www.xsens.com). The new calibration appears to be valid for at least 22 days providing the sensor is not exposed to high impacts. However, if several sensors are 'daisy chained' together changes to the magnetometer bias can cause heading errors of up to 15 degrees . The results demonstrate the non-linear relationship between the vendor's orthogonality claim of < 0.1 degrees and the accuracy of 3D orientation obtained from factory calibrated IMUs in static situations. The authors hypothesise that the high magnetic dip (64 degrees ) in our laboratory may have exacerbated the errors reported. For biomechanical research, small relative movements of a body segment from a calibrated position are likely to be more accurate than large scale global motion that may have an error of up to 9.8 degrees . PMID:18688763

  2. Calibration of 3-D wind measurements on a single-engine research aircraft

    NASA Astrophysics Data System (ADS)

    Mallaun, C.; Giez, A.; Baumann, R.

    2015-08-01

    An innovative calibration method for the wind speed measurement using a boom-mounted Rosemount model 858 AJ air velocity probe is introduced. The method is demonstrated for a sensor system installed on a medium-size research aircraft which is used for measurements in the atmospheric boundary layer. The method encounters a series of coordinated flight manoeuvres to directly estimate the aerodynamic influences on the probe and to calculate the measurement uncertainties. The introduction of a differential Global Positioning System (DGPS) combined with a high-accuracy inertial reference system (IRS) has brought major advances to airborne measurement techniques. The exact determination of geometrical height allows the use of the pressure signal as an independent parameter. Furthermore, the exact height information and the stepwise calibration process lead to maximum accuracy. The results show a measurement uncertainty for the aerodynamic influence of the dynamic and static pressures of 0.1 hPa. The applied parametrisation does not require any height dependencies or time shifts. After extensive flight tests a correction for the flow angles (attack and sideslip angles) was found, which is necessary for a successful wind calculation. A new method is demonstrated to correct for the aerodynamic influence on the sideslip angle. For the three-dimensional (3-D) wind vector (with 100 Hz resolution) a novel error propagation scheme is tested, which determines the measurement uncertainties to be 0.3 m s-1 for the horizontal and 0.2 m s-1 for the vertical wind components.

  3. Calibration of 3-D wind measurements on a single engine research aircraft

    NASA Astrophysics Data System (ADS)

    Mallaun, C.; Giez, A.; Baumann, R.

    2015-02-01

    An innovative calibration method for the wind speed measurement using a boom mounted Rosemount model 858 AJ air velocity probe is introduced. The method is demonstrated for a sensor system installed on a medium size research aircraft which is used for measurements in the atmospheric boundary layer. The method encounters a series of coordinated flight manoeuvres to directly estimate the aerodynamic influences on the probe and to calculate the measurement uncertainties. The introduction of a differential Global Positioning System (DGPS) combined with a high accuracy Inertial Reference System (IRS) has brought major advances to airborne measurement techniques. The exact determination of geometrical height allows the use of the pressure signal as an independent parameter. Furthermore, the exact height information and the stepwise calibration process lead to maximum accuracy. The results show a measurement uncertainty for the aerodynamic influence of the dynamic and static pressures of 0.1 hPa. The applied parametrisation does not require any height dependencies or time shifts. After extensive flight tests a correction for the flow angles (attack and sideslip angles) was found, which is necessary for a successful wind calculation. A new method is demonstrated to correct for the aerodynamic influence on the sideslip angle. For the 3-D wind vector (with 100 Hz resolution) a novel error propagation scheme is tested, which determines the measurement uncertainties to be 0.3 m s-1 for the horizontal and 0.2 m s-1 for the vertical wind components.