Science.gov

Sample records for 3-phase bone scan

  1. Bone scanning.

    PubMed

    Greenfield, L D; Bennett, L R

    1975-03-01

    Scanning is based on the uptake of a nuclide by the crystal lattice of bone and is related to bone blood flow. Cancer cells do not take up the tracer. Normally, the scan visualizes the highly vascular bones. Scans are useful and are indicated in metastatic bone disease, primary bone tumors, hematologic malignancies and some non-neoplastic diseases. The scan is more sensitive than x-ray in the detection of malignant diseases of the skeleton. PMID:1054210

  2. The bone scan.

    PubMed

    Brenner, Arnold I; Koshy, June; Morey, Jose; Lin, Cheryl; DiPoce, Jason

    2012-01-01

    Bone imaging continues to be the second greatest-volume nuclear imaging procedure, offering the advantage of total body examination, low cost, and high sensitivity. Its power rests in the physiological uptake and pathophysiologic behavior of 99m technetium (99m-Tc) diphosphonates. The diagnostic utility, sensitivity, specificity, and predictive value of 99m-Tc bone imaging for benign conditions and tumors was established when only planar imaging was available. Currently, nearly all bone scans are performed as a planar study (whole-body, 3-phase, or regional), with the radiologist often adding single-photon emission computed tomography (SPECT) imaging. Here we review many current indications for planar bone imaging, highlighting indications in which the planar data are often diagnostically sufficient, although diagnosis may be enhanced by SPECT. (18)F sodium fluoride positron emission tomography (PET) is also re-emerging as a bone agent, and had been considered interchangeable with 99m-Tc diphosphonates in the past. In addition to SPECT, new imaging modalities, including (18)F fluorodeoxyglucose, PET/CT, CT, magnetic resonance, and SPECT/CT, have been developed and can aid in evaluating benign and malignant bone disease. Because (18)F fluorodeoxyglucose is taken up by tumor cells and Tc diphosphonates are taken up in osteoblastic activity or osteoblastic healing reaction, both modalities are complementary. CT and magnetic resonance may supplement, but do not replace, bone imaging, which often detects pathology before anatomic changes are appreciated. We also stress the importance of dose reduction by reducing the dose of 99m-Tc diphosphonates and avoiding unnecessary CT acquisitions. In addition, we describe an approach to image interpretation that emphasizes communication with referring colleagues and correlation with appropriate history to significantly improve our impact on patient care.

  3. Bone scanning in severe external otitis

    SciTech Connect

    Levin, W.J.; Shary, J.H. 3d.; Nichols, L.T.; Lucente, F.E.

    1986-11-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis.

  4. Diagnosis of thyroid disease on bone scans

    SciTech Connect

    Peterdy, A.E.

    1985-03-01

    Three cases are reported in which visualization of the thyroid occurred during Tc-99m pyrophosphate bone scans. All were found to be hyperthyroid with elevated serum thyroid hormone and two patients also had elevated 4-hour radioactive iodine uptakes.

  5. Radionuclide bone scanning of medullary chondrosarcoma

    SciTech Connect

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-12-01

    /sup 99m/Tc methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan uptake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the extended pattern of uptake beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogeneous uptake on the scan.

  6. Radionuclide bone scanning in giant cell tumor

    SciTech Connect

    Van Nostrand, D.; Madewell, J.E.; McNiesh, L.M.; Kyle, R.W.; Sweet, D.

    1986-03-01

    Radionuclide bone scan findings are described and correlated with pathology in 23 patients with giant cell tumor (GCT) of the bone. The degree of radionuclide activity was markedly increased in 20 (87%), minimally increased in three (13%), and decreased in none of the patients. Of the 23 patients with increased radioactivity, the pattern was diffuse in 11 (48%) and doughnut in 12 (52%). Extended patterns of radioactivity were present in 19 of 22 patients; however, none were associated with true tumor extension. Bone scanning did not aid in the detection of GCT, was nonspecific, and did not differentiate benign from malignant GCT. Although radioactivity extended beyond the radiographic abnormality in the majority of patients, this was most likely secondary to other bony abnormalities or local and/or regional hyperemia, and caution should be taken in ascribing this extension to either tumor or metastasis.

  7. Intracranial extramedullary hematopoiesis. CT and bone marrow scan findings

    SciTech Connect

    Urman, M.; O'Sullivan, R.A.; Nugent, R.A.; Lentle, B.C. )

    1991-06-01

    This case concerns a patient with intracranial extramedullary hematopoiesis (EH) suspected on a CT scan and subsequently confirmed with In-111 chloride and Tc-99m SC bone marrow scans. The bone marrow scans also provided additional information by demonstrating other sites of EH in the paravertebral tissues and bone marrow expansion into the distal extremities.

  8. Radionuclide bone scanning of osteosarcoma: falsely extended uptake patterns

    SciTech Connect

    Chew, F.S.; Hudson, T.M.

    1982-07-01

    The pathologic specimens of 18 osteosarcomas of long bones were examined to correlate histologic abnormalities with abnormalities seen on preoperative /sup 99m/Tc pyrophosphate or methylene diphosphonate bone scans. Seven scans accurately represented the extent of the tumor. Eleven scans disclosed increased activity extending beyond the radiographic abnormalities. In eight of these, there was no occult tumor extension and in the other three, the scan activity did not accurately portray the skip metastases that were present. Therefore, these 11 scans demonstrated the falsely extended pattern of uptake beyond the true limits of the tumors. Pathologic slides were available for 10 of the 11 areas of bone that exhibited extended uptake. In two instances, there was no pathologic abnormality. In the other eight cases we found marrow hyperemia, medullary reactive bone, or periosteal new bone. This is the first description of these histologic abnormalities of medullary bone in areas of extended uptake on radionuclide bone scans.

  9. Bone scanning in the detection of occult fractures

    SciTech Connect

    Batillas, J.; Vasilas, A.; Pizzi, W.F.; Gokcebay, T.

    1981-07-01

    The potential role of bone scanning in the early detection of occult fractures following acute trauma was investigated. Technetium 99m pyrophosphate bone scans were obtained in patients with major clinical findings and negative or equivocal roentgenograms following trauma. Bone scanning facilitated the prompt diagnosis of occult fractures in the hip, knee, wrist, ribs and costochondral junctions, sternum, vertebrae, sacrum, and coccyx. Several illustrative cases are presented. Roentgenographic confirmation occurred following a delay of days to weeks and, in some instances, the roentgenographic findings were subtle and could be easily overlooked. This study demonstrates bone scanning to be invaluable and definitive in the prompt detection of occult fractures.

  10. Bone Positron Emission Tomography with or without CT Is More Accurate than Bone Scan for Detection of Bone Metastasis

    PubMed Central

    Lee, Soo Jin; Kim, Sang Eun

    2013-01-01

    Objective Na18F bone positron emission tomography (bone PET) is a new imaging modality which is useful for the evaluation of bone diseases. Here, we compared the diagnostic accuracies between bone PET and bone scan for the detection of bone metastasis (BM). Materials and Methods Sixteen cancer patients (M:F = 10:6, mean age = 60 ± 12 years) who underwent both bone PET and bone scan were analyzed. Bone PET was conducted 30 minutes after the injection of 370 MBq Na18F, and a bone scan was performed 3 hours after the injection of 1295 MBq 99mTc-hydroxymethylene diphosphonate. Results In the patient-based analysis (8 patients with BM and 8 without BM), the sensitivities of bone PET (100% = 8/8) and bone scan (87.5% = 7/8) were not significantly different (p > 0.05), whereas the specificity of bone PET (87.5% = 7/8) was significantly greater than that of the bone scan (25% = 2/8) (p < 0.05). In the lesion-based analysis (43 lesions in 14 patients; 31 malignant and 12 benign), the sensitivity of bone PET (100% = 31/31) was significantly greater than that of bone scan (38.7% = 12/31) (p < 0.01), and the specificity of bone PET (75.0% = 9/12) was also significantly higher than that of bone scan (8.3% = 1/12) (p < 0.05). The receiver operating characteristic curve analysis showed that bone PET was significantly more accurate than the bone scan in the patient (p = 0.0306) and lesion (p = 0.0001) based analyses. Conclusion Na18F bone PET is more accurate than bone scan for BM evaluation. PMID:23690722

  11. Radioisotope bone scanning in a case of sarcoidosis

    SciTech Connect

    Cinti, D.C.; Hawkins, H.B.; Slavin, J.D. Jr.

    1985-03-01

    The application of radioisotope scanning to osseous involvement from systemic sarcoidosis has been infrequently described in the scientific literature. Most commonly, the small bones of the hands and feet are affected if sarcoidosis involves the skeleton. Nonetheless, there are also occasional manifestations of sarcoid in the skull, long bones, and vertebral bodies. This paper describes a case of sarcoid involving the lung parenchyma with multiple lesions in the skull and ribs demonstrated by bone scanning with Tc-99m MDP. Following treatment with steroids, the bone scan showed complete resolution of the rib lesions and almost complete resolution of the lesions in the calvarium.

  12. New Drug for Use in Bone Scans Approved

    Cancer.gov

    The FDA has approved a New Drug Application (NDA) from the National Cancer Institute (NCI), part of the National Institutes of Health, for a new strength of a previously approved drug, Sodium Fluoride F18, for use in bone scans. In contrast to Technetium-99m (Tc-99m), which has been the only approved radioactive tracer for bone scans, Sodium Fluoride F18 is not subject to the supply problems that have led to recent nationwide shortages of Tc-99m.

  13. Diverse bone scan abnormalitites in "shin splints".

    PubMed

    Spencer, R P; Levinson, E D; Baldwin, R D; Sziklas, J J; Witek, J T; Rosenberg, R

    1979-12-01

    Four young patients who presented with pain over the anterior compartment of the legs, gave a recent athletic history suggesting stress fractures. Although radiographs were initially normal in all four cases, the bone scintigrams were positive. The individual findings, however, were quite different. In one there was a single focal area of increased radioactivity in each of the tibias; the second patient had uneven uptake of radiotracer and several foci of accumulation in the fibulas; the third showed diffuse linear tibial uptake suggesting periosteal lesions; and the fourth case revealed uptake in the lateral malleolus and in bones of the foot.

  14. Does aspiration of bones and joints affect results of later bone scanning

    SciTech Connect

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan.

  15. Skeletal blood flow: implications for bone-scan interpretation

    SciTech Connect

    Charkes, N.D.

    1980-01-01

    The dispersion of the skeleton throughout the body and its complex vascular anatomy require indirect methods for the measurement of skeletal blood flow. The results of one such method, compartmental analysis of skeletal tracer kinetics, are presented. The assumptions underlying the models were tested in animals and found to be in agreement with experimental observations. Based upon the models and the experimental results, inferences concerning bone-scan interpretation can be drawn: decreased cardiac output produces low-contrast (technically poor) scans; decreased skeletal flow produces photon-deficient lesions; increase of cardiac output or of generalized systemic blood flow is undetectable 1 to 2 h after dose; increased local skeletal blood flow results from disturbance of the bone microvasculature and can occur from neurologic (sympatholytic) disorders or in association with focal abnormalities that also incite the formation of reactive bone (e.g., metastasis, fracture, etc.). Mathematical solutions of tracer kinetic data thus become relevant to bone-scan interpretation.

  16. Gallium scanning in Paget's disease of bone: effect of calcitonin

    SciTech Connect

    Waxman, A.D.; McKee, D.; Siemsen, J.K.; Singer, F.R.

    1980-02-01

    Calcitonin has been used in the treatment of Paget's disease of bone, and serum alkaline phosphatase level and 24 hr urinary hydroxyproline excretion have been used to follow therapeutic response. The radionuclide bone scan has been used as a visual indicator; however, there is some uncertainty as to its value in following changes in disease activity. Four patients with both serial technetium phosphate bone scans and serial gallium studies were studied. In each case the beneficial effect of calcitonin was demonstrated more accurately with gallium than with technetium diphosphonate. Since biochemical changes in Paget's disease are believed to be mediated at the cellular level and gallium uptake depends on cellular activity, it is proposed that gallium uptake is more appropriate measure of the activity of Paget's disease than a noncellular marker such as a technetium-containing bone scan agent.

  17. Bone Scanning in the Adductor Insertion Avulsion Syndrome

    PubMed Central

    Mahajan, Madhuri Shimpi

    2013-01-01

    A thigh splint (adductor insertion avulsion syndrome) is a relatively uncommon diagnosis analogous to shin splints. This article reports a 19-year-old female patient NOT a regular athlete who presented with groin pain. Physical examination was non-specific; magnetic resonance imaging pelvis did not reveal any abnormality. Patient referred for whole body bone scan, especially to locate any abnormality in the spine. This study highlights the role of whole body bone scan in the evaluation of groin pain and importance of evaluation of whole lower extremity. PMID:25126001

  18. Confocal laser scanning microscopy in study of bone calcification

    NASA Astrophysics Data System (ADS)

    Nishikawa, Tetsunari; Kokubu, Mayu; Kato, Hirohito; Imai, Koichi; Tanaka, Akio

    2012-12-01

    Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 μm/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  19. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    NASA Astrophysics Data System (ADS)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  20. Liver uptake on bone scanning: a diagnostic algorithm.

    PubMed

    Al-Katib, Sayf; Al-Faham, Zaid; Balon, Helena

    2015-06-01

    In this report, we present a case of liver uptake seen on a bone scan that was due to diffuse metastatic disease from breast carcinoma. We discuss possible etiologies for the uptake and offer an algorithm to narrow the differential diagnosis.

  1. Metastatic calcification of the stomach imaged on a bone scan

    SciTech Connect

    Goldstein, R.; Ryo, U.Y.; Pinsky, S.M.

    1984-10-01

    A whole body bone scan obtained on a 21-year-old woman with sickle cell disease and chronic renal failure showed localization of the radionuclide diffusely in the stomach. The localization of the radionuclide represented metastatic calcification of the stomach caused by secondary hyperparathyroidism.

  2. TC MDP bone scan in evaluation of painful scoliosis.

    PubMed

    Nilegaonkar, Sujit; Sonar, Sameer; Ranade, Ashish; Khadilkar, Madhav

    2010-04-01

    A 18-year-old male presented with low back ache. The patient was investigated and was diagnosed to have painful scoliosis. X-ray and other examinations could not reveal any diagnosis. The patient was referred to undergo bone scan on clinical suspicion of osteoid osteoma and to rule out stress fracture if any. Planar bone scan was performed, which showed a lesion in L3 vertebra and was further evaluated with SPECT (Single photon emission computed tomography) study to characterize the lesion. On SPECT examination, the classical features of osteoid osteoma, the double density sign (11), was noted in the pars interarticularis region. These findings were confirmed by a CT scan, which showed a sclerotic lesion in pars interarticularis of L3 vertebra. The patient was posted for operation and was relieved of symptoms in the postoperative follow-up.

  3. Bone scans and the timing of treatment for condylar hyperplasia.

    PubMed

    Robinson, P D; Harris, K; Coghlan, K C; Altman, K

    1990-08-01

    Bone scintiscans comparing the uptake of technetium 99 in the normal and affected condyles of 10 patients with unilateral condylar hyperplasia were recorded at or after the time when overall growth had ceased. The scans of 6 patients demonstrated persisting increased growth activity at this time. In 2 of these cases where the abnormal condyles showed uptakes of 240% and 170% with respect to the normal side, the nature and timing of treatment were changed when the results of the scans were known. PMID:2120367

  4. Visualizing bone porosities using a tabletop scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Krishnamoorthy, D.; DaPonte, J.; Broadbridge, C. C.; Daniel, D.; Alter, L.

    2010-04-01

    Pores are naturally occurring entities in bone. Changes in pore size and number are often associated with diseases such as Osteoporosis and even microgravity during spaceflight. Studying bone perforations may yield great insight into bone's material properties, including bone density and may contribute to identifying therapies to halt or potentially reverse bone loss. Current technologies used in this field include nuclear magnetic resonance, micro-computed tomography and the field emission scanning electron microscope (FE-SEM) 2, 5. However, limitations in each method limit further advancement. The objective of this study was to assess the effectiveness of using a new generation of analytical instruments, the TM-1000 tabletop, SEM with back-scatter electron (BSE) detector, to analyze cortical bone porosities. Hind limb unloaded and age-based controlled mouse femurs were extracted and tested in vitro for changes in pores on the periosteal surface. An important advantage of using the tabletop is the simplified sample preparation that excludes extra coatings, dehydration and fixation steps that are otherwise required for conventional SEM. For quantitative data, pores were treated as particles in order to use an analyze particles feature in the NIH ImageJ software. Several image-processing techniques for background smoothing, thresholding and filtering were employed to produce a binary image suitable for particle analysis. It was hypothesized that the unloaded bones would show an increase in pore area, as the lack of mechanical loading would affect bone-remodeling processes taking place in and around pores. Preliminary results suggest only a slight different in frequency but not in size of pores between unloaded and control femurs.

  5. Os trigonum syndrome: use of bone scan in the diagnosis

    SciTech Connect

    Johnson, R.P.; Collier, B.D.; Carrera, G.F.

    1984-08-01

    The os trigonum is an accessory bone of the foot found in 7% of the normal adult population. It is located at the posterolateral projection of the talus, and can occasionally give rise to symptoms of acute and chronic unexplained ankle pain. We report three patients, one with acute fracture and two with chronic ankle symptoms. Technetium 99 methylene diphosphonate showed intense focal uptake at the posterior talus pointing to the os trigonum as the site of symptoms. It was excised in two patients with complete relief. The third went on to develop an asymptomatic nonunion. We recommend bone scanning as a procedure that is helpful in delineating obscure pain in the ankle that may be due to chronic irritative nonunion of the os trigonum.

  6. Bone scanning in the adductor insertion avulsion syndrome ("thigh splints").

    PubMed

    Charkes, N D; Siddhivarn, N; Schneck, C D

    1987-12-01

    Shin splints is a defined clinical entity resulting from extreme tension on muscles inserting on the tibia, resulting in periosteal elevation which is detectable by bone scanning. The clinical equivalent in the thigh has been described. We found scintigraphic changes in the femurs of seven short, female, basic trainees at the Fort Dix Army base, most of whom were referred for stress fractures elsewhere in the lower extremities. The scan findings were generally noted in the upper or mid femurs, always involved the anteromedial cortex, and were bilateral in five of the seven subjects. The abnormalities were linear and suggested periosteal elevation, and did not have the typical appearance of stress fracture. Since the findings correspond to the insertion of one or more adductor muscle groups, the descriptive term "adductor insertion avulsion syndrome" or "thigh splints" is proposed for this entity.

  7. Benign Brenner tumor of the ovary detected on Tc-99m methylene diphosphonate bone scan

    SciTech Connect

    Renner, J.B.; McCartney, W.H.

    1984-11-01

    Many disease states, including neoplasia, have been detected by bone scanning. Among the neoplastic processes detected by bone imaging agents are ovarian tumors, both benign and malignant. This report is concerned with the visualization of a benign Brenner tumor during routine Tc-99m MDP bone scanning.

  8. Automated alignment of serial thoracic scans using bone structure descriptors

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; Petrick, Nicholas; Myers, Kyle J.

    2007-03-01

    In this manuscript we present an automated algorithm for the alignment of thoracic scans using descriptors of bone structures. Bone structures were utilized because they are expected to be less susceptible to sources of errors such as patient positioning and breath hold. The algorithm employed the positioning of ribs relative to the spinal cord along with a description of the scapula. The spinal cord centroid was detected by extracting local maxima of the distance transform followed by point tracing along consecutive slices. Ribs were segmented using adaptive thresholding followed by the watershed algorithm to detach ribs from the vertebra, and by imposing requirements of rib proximity to the lung border. The angles formed between the spinal cord centroid and segmented rib centroids were used to describe rib positioning. Additionally, the length of the scapula was extracted in each slice. A cost function incorporating the difference of features from rib positioning and scapula length between two slices was derived and used to match slices. The method was evaluated on a set of 12 pairs of full and partial CT scans acquired on the same day. Evaluation was based on whether the slices showing a nodule at its maximum diameter in each scan were matched. Full-to-partial and partial-to-full alignment were performed. Results showed that the proposed metric matched nodule slices within an average distance of 1.08 and 1.17 slices from the target for full-to-partial and partial-to-full alignment respectively. These preliminary results are encouraging for using this method as a first step in an overall process of temporally analyzing CT lung nodules.

  9. Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

    SciTech Connect

    Falchook, Aaron D.; Salloum, Ramzi G.; Hendrix, Laura H.; Chen, Ronald C.

    2014-06-01

    Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

  10. Scanning electron microscopy of human cortical bone failure surfaces.

    PubMed

    Braidotti, P; Branca, F P; Stagni, L

    1997-02-01

    Undecalcified samples extracted from human femoral shafts are fractured by bending and the fracture surfaces are examined with a scanning electron microscope (SEM). The investigation is performed on both dry and wet (hydrated with a saline solution) specimens. SEM micrographs show patterns in many respects similar to those observed in fractography studies of laminated fiber-reinforced synthetic composites. In particular, dry and wet samples behave like brittle and ductile matrix laminates, respectively. An analysis carried out on the basis of the mechanisms that dominate the fracture process of laminates shows that a reasonable cortical bone model is that of a laminated composite material whose matrix is composed of extracellular noncollagenous calcified proteins, and the reinforcement is constituted by the calcified collagen fiber system. PMID:9001936

  11. Bone scanning in patients with early breast carcinoma: should it be a routine staging procedure

    SciTech Connect

    Lee, Y.T.

    1981-02-01

    Bone scanning is a sensitive test for the detection of metastatic breast cancer, but not all abnormal findings on bone scan are diagnostic of skeletal metastasis. Recent studies have found a relatively low rate (less than or equal to 5%) of abnormal scans in patients with Stage I and II breast cancers, and only half of those with positive scans subsequently had documented bony metastasis. The overwhelming clinical experiences summarized here question the value of including bone scanning as part of the routine work-up of patients with early breast cancers.

  12. [Differential diagnosis of reduced uptake images revealed by bone scan: about a case of acute lymphoblastic leukemia].

    PubMed

    Bahadi, Nisrine; Biyi, Abdelhamid; Oueriagli, Salah Nabih; Doudouh, Abderrahim

    2016-01-01

    If increased uptake during bone scan usually bring to light many bone pathologies, reduced uptakes are a rare occurrence and they require careful analysis to avoid erroneous interpretations. We report the case of a 17-year old admitted with diffuse bone pain, hypercalcemia and thrombopenia. Bone scan showed areas of low uptakes. Bone marrow tests allowed the diagnosis of acute lymphoblastic leukemia. This case report aims to discuss the main differential diagnoses based on such bone scan abnormalities. PMID:27642484

  13. Role of bone and liver scans in surveying patients with breast cancer for metastatic disease

    SciTech Connect

    Evans, D.M.; Wright, D.J.

    1987-10-01

    The objective of this study is to correlate the presence of bone and liver metastases in patients with breast cancer with respect to the results of bone and liver scans, axillary nodal status, and serum alkaline phosphatase levels. One hundred ninety-seven patients with breast cancer treated by modified radical mastectomy between the years 1978 and 1981 were studied. Fifty-nine (30%) of the total group had distant metastases during the course of observation of 60 to 96 months; of 35 patients in whom bone metastases developed, 30 had normal preoperative bone scan results. Of 21 patients who had liver metastases, 19 had normal preoperative liver scans. Nineteen (70%) of the 27 patients with abnormal bone scans had normal alkaline phosphatase levels. Seven (63%) of the 11 patients who had abnormal liver scans had a normal alkaline phosphatase. The study supports the concept that preoperative bone and liver scans are ineffective indicators of metastatic involvement. Selection of patients for screening by bone and liver scans according to alkaline phosphatase determinations was not supported by this study. The appropriate use of bone scans for screening in patients with breast carcinoma is suggested as a follow-up device in patients with positive lymph nodes.

  14. Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma

    SciTech Connect

    Mettler, F.A. Jr.; Christie, J.H.; Garcia, J.F.; Baldwin, M.H.; Wicks, J.D.; Bartow, S.A.

    1981-12-01

    Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening for liver metastases in patients with endometrial carcinoma is not warranted in patients with normal liver function studies.

  15. Comparison of bone scans and radiography for detecting bone neoplasms in dogs exposed to /sup 238/PuO/sub 2/

    SciTech Connect

    Wolff, R.K.; Merickel, B.S.; Rebar, A.H.; Mewhinney, J.A.

    1980-11-01

    Radioisotopic bone scans and radiography were used to detect bone neoplasms in 144 dogs that inhaled alpha-particle-emitting /sup 238/PuO/sub 2/ particles. Radiography was used routinely to survey the skeleton of the dogs. Nineteen dogs developed bone neoplasms; 17 of these were studied with bone scans and radiography; both methods showed a high degree of success in detecting bone neoplasms. Predominant regions of occurrence have been the lumbar region of the spine and the humerus. The bone scanning method used gamma-camera detection of IV injected 99mTc-labeled methylene diphosphonate. All neoplasms detected radiographically also were identified by bone scans. In addition, 3 lesions confirmed histologically as osteosarcomas were detected by bone scanning, but were missed by radiography. Bone scanning was a more sensitive means for the detection of bone neoplasms than were routine radiographic procedures.

  16. Extraosseous accumulation of bone scan tracer (99m)Tc-methylene diphosphonate in a phlebolith.

    PubMed

    Kulkarni, Mukta; Agrawal, Archi; Zade, Anand; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2012-01-01

    Uptake in non-osseous, non-urologic tissues is occasionally found in the performance of bone scintigraphy. These uptakes reflect an atypical interaction between the radiopharmaceutical and the patient. Knowledge of the rare extraskeletal uptakes and their clinical relevance helps in better interpretation of bone scans. We report an unusual occurrence of extraosseous accumulation of (99m)Tc-methylene diphosphonate in a phlebolith in bone scan, confirmed with the aid of photon emission computed tomography and computed tomography. PMID:23599599

  17. Extraosseous accumulation of bone scan tracer 99mTc-methylene diphosphonate in a phlebolith

    PubMed Central

    Kulkarni, Mukta; Agrawal, Archi; Zade, Anand; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2012-01-01

    Uptake in non-osseous, non-urologic tissues is occasionally found in the performance of bone scintigraphy. These uptakes reflect an atypical interaction between the radiopharmaceutical and the patient. Knowledge of the rare extraskeletal uptakes and their clinical relevance helps in better interpretation of bone scans. We report an unusual occurrence of extraosseous accumulation of 99mTc-methylene diphosphonate in a phlebolith in bone scan, confirmed with the aid of photon emission computed tomography and computed tomography. PMID:23599599

  18. Histologically proven pressure sore-related osteomyelitis in the setting of negative technetium bone scans. Case report.

    PubMed

    Burdge, D R; Gribble, M J

    1993-12-01

    Pressure sores are common in patients with spinal cord injury, stroke or debilitating medical illness. Contiguous osteomyelitis is a well recognized complication of pressure ulcers, but remains a challenging diagnostic and management problem. Technetium bone scan is purported to be an extremely sensitive, although nonspecific diagnostic test for osteomyelitis. Indeed, a negative bone scan is thought to virtually exclude bone infection. We report three cases of pressure sore-related polymicrobial osteomyelitis where technetium bone scan was normal, yet bone biopsy demonstrated characteristic histopathologic changes of osteomyelitis. These cases raise questions regarding the sensitivity of bone scanning in the setting of pressure sores, and they demonstrate the need for further investigation into the correlation between nuclear medicine scan results and bone biopsy histopathology. Bone biopsy remains the gold standard for diagnosis of osteomyelitis, which can be present in bone underlying a pressure ulcer, even in the setting of a normal bone scan.

  19. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    SciTech Connect

    Sundberg, S.B.; Savage, J.P.; Foster, B.K. )

    1989-09-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis.

  20. Preliminary results of automated removal of degenerative joint disease in bone scan lesion segmentation

    NASA Astrophysics Data System (ADS)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Auerbach, Martin; Goldin, Jonathan; Henkel, Keith; Banola, Ashley; Morris, Darren; Coy, Heidi; Brown, Matthew S.

    2013-03-01

    Whole-body bone scintigraphy (or bone scan) is a highly sensitive method for visualizing bone metastases and is the accepted standard imaging modality for detection of metastases and assessment of treatment outcomes. The development of a quantitative biomarker using computer-aided detection on bone scans for treatment response assessment may have a significant impact on the evaluation of novel oncologic drugs directed at bone metastases. One of the challenges to lesion segmentation on bone scans is the non-specificity of the radiotracer, manifesting as high activity related to non-malignant processes like degenerative joint disease, sinuses, kidneys, thyroid and bladder. In this paper, we developed an automated bone scan lesion segmentation method that implements intensity normalization, a two-threshold model, and automated detection and removal of areas consistent with non-malignant processes from the segmentation. The two-threshold model serves to account for outlier bone scans with elevated and diffuse intensity distributions. Parameters to remove degenerative joint disease were trained using a multi-start Nelder-Mead simplex optimization scheme. The segmentation reference standard was constructed manually by a panel of physicians. We compared the performance of the proposed method against a previously published method. The results of a two-fold cross validation show that the overlap ratio improved in 67.0% of scans, with an average improvement of 5.1% points.

  1. Combined bone scintigraphy and indium-111 leukocyte scans in neuropathic foot disease

    SciTech Connect

    Schauwecker, D.S.; Park, H.M.; Burt, R.W.; Mock, B.H.; Wellman, H.N.

    1988-10-01

    It is difficult to diagnose osteomyelitis in the presence of neurotrophic osteoarthropathy. We performed combined (99mTc)MDP bone scans and indium-111 (111In) leukocyte studies on 35 patients who had radiographic evidence of neuropathic foot disease and clinically suspected osteomyelitis. The (111In)leukocyte study determined if there was an infection and the bone scan provided the anatomic landmarks so that the infection could be localized to the bone or the adjacent soft tissue. Seventeen patients had osteomyelitis and all showed increased (111In)leukocyte activity localized to the bone, giving a sensitivity of 100%. Among the 18 patients without osteomyelitis, eight had no accumulation of (111In)leukocytes, seven had the (111In)leukocyte activity correctly localized to the soft tissue, two had (111In)leukocyte activity mistakenly attributed to the bone, and one had (111In)leukocyte accumulation in a proven neuroma which was mistakenly attributed to bone. These three false-positive results for osteomyelitis reduced the specificity to 83%. Considering only the 27 patients with a positive (111In)leukocyte study, the combined bone scan and (111In)leukocyte study correctly localized the infection to the soft tissues or bone in 89%. Uninfected neurotrophic osteoarthropathy does not accumulate (111In)leukocytes. We found the combined bone scan and (111In) leukocyte study useful for the detection and localization of infection to soft tissue or bone in patients with neuropathic foot disease.

  2. Is there still a place for bone scanning in Ewing's sarcoma: concise communication. [/sup 99/Tc, /sup 18/Fl

    SciTech Connect

    Goldstein, H.; McNeil, B.J.; Zufall, E.; Treves, S.

    1980-01-01

    In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.

  3. Automated segmentation of tumors on bone scans using anatomy-specific thresholding

    NASA Astrophysics Data System (ADS)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Lu, Peiyun; Ramakrishna, Bharath; Gjertson, David; Poon, Cheryce; Auerbach, Martin; Goldin, Jonathan; Brown, Matthew S.

    2012-03-01

    Quantification of overall tumor area on bone scans may be a potential biomarker for treatment response assessment and has, to date, not been investigated. Segmentation of bone metastases on bone scans is a fundamental step for this response marker. In this paper, we propose a fully automated computerized method for the segmentation of bone metastases on bone scans, taking into account characteristics of different anatomic regions. A scan is first segmented into anatomic regions via an atlas-based segmentation procedure, which involves non-rigidly registering a labeled atlas scan to the patient scan. Next, an intensity normalization method is applied to account for varying levels of radiotracer dosing levels and scan timing. Lastly, lesions are segmented via anatomic regionspecific intensity thresholding. Thresholds are chosen by receiver operating characteristic (ROC) curve analysis against manual contouring by board certified nuclear medicine physicians. A leave-one-out cross validation of our method on a set of 39 bone scans with metastases marked by 2 board-certified nuclear medicine physicians yielded a median sensitivity of 95.5%, and specificity of 93.9%. Our method was compared with a global intensity thresholding method. The results show a comparable sensitivity and significantly improved overall specificity, with a p-value of 0.0069.

  4. Role of nuclear medicine bone scans in evaluating pain in athletic injuries

    SciTech Connect

    Martire, J.R.

    1987-10-01

    The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

  5. Bone scan: Indium-WBC correlation in the diagnosis of osteomyelitis of the foot

    SciTech Connect

    Eisenberg, B.; Wrege, S.S.; Altman, M.I.; Moore, J.W. )

    1989-11-01

    A retrospective study was performed of 20 podiatric cases using technetium-99m methylene diphosphonate three-phase bone scans along with indium-111 oxine leukocyte scans, as needed, to determine the presence and extent of osteomyelitis of the foot. Using criteria developed at our institution, the authors attempt to provide a mechanism to make a reliable diagnosis for osteomyelitis that has been supported by surgical/pathologic confirmation of long-term clinical follow-up. The sensitivity, using bone scans alone, was 100%, and specificity was 47%. Correlating bone and indium-111 leukocyte scans yielded a sensitivity of 100% with a specificity raised to 81%. Indium-111 leukocyte scans were used in 40% of cases when a definitive diagnosis for osteomyelitis could not be made on the basis of the three-phase bone scan or clinical presentation alone. Indium-111 leukocyte scans were also helpful in delineating the extent of the disease process. The authors present a standard technique for a 5-hour delayed imaging in the three-phase bone scan, as well as marking the foot in the indium-111 leukocyte scan with three routine views obtained for each imaging procedure, to ensure clinical accuracy.

  6. Computer-aided quantitative bone scan assessment of prostate cancer treatment response

    PubMed Central

    Brown, Matthew S.; Chu, Gregory H.; Kim, Hyun J.; Allen-Auerbach, Martin; Poon, Cheryce; Bridges, Juliette; Vidovic, Adria; Ramakrishna, Bharath; Ho, Judy; Morris, Michael J.; Larson, Steven M.; Scher, Howard I.; Goldin, Jonathan G.

    2012-01-01

    Objective The development and evaluation of a computer-aided bone scan analysis technique to quantify changes in tumor burden and assess treatment effects in prostate cancer clinical trials. Methods We have developed and report on a commercial fully automated computer-aided detection system. Using this system, scan images were intensity normalized, then lesions identified and segmented by anatomic region-specific intensity thresholding. Detected lesions were compared against expert markings to assess the accuracy of the computer-aided detection system. The metrics Bone Scan Lesion Area, Bone Scan Lesion Intensity, and Bone Scan Lesion Count were calculated from identified lesions, and their utility in assessing treatment effects was evaluated by analyzing before and after scans from metastatic castration-resistant prostate cancer patients: 10 treated and 10 untreated. In this study, patients were treated with cabozantinib, a MET/VEGF inhibitor resulting in high rates of resolution of bone scan abnormalities. Results Our automated computer-aided detection system identified bone lesion pixels with 94% sensitivity, 89% specificity, and 89% accuracy. Significant differences in changes from baseline were found between treated and untreated groups in all assessed measurements derived by our system. The most significant measure, Bone Scan Lesion Area, showed a median (interquartile range) change from baseline at week 6 of 7.13% (27.61) in the untreated group compared with −73.76% (45.38) in the cabozantinib-treated group (P = 0.0003). Conclusions Our system accurately and objectively identified and quantified metastases in bone scans, allowing for interpatient and intrapatient comparison. It demonstrates potential as an objective measurement of treatment effects, laying the foundation for validation against other clinically relevant outcome measures. PMID:22367858

  7. Self-scanning of a dye laser due to feedback from a BaTiO/sub 3/ phase-conjugate reflector

    SciTech Connect

    Whitten, W.B.; Ramsey, J.M.

    1984-02-01

    Feedback from a self-pumped BaTiO/sub 3/ phase-conjugate reflector into an untuned cw dye laser produces substantial line narrowing (4--6 GHz) and generates a recurrent wavelength sweep from the rhodamine 6G peak at 618 nm to as far as 644 nm.

  8. Comparison of bone scan with carbohydrate antigen 15-3 for evaluation of bone metastasis of brest cancer.

    PubMed

    Mohammadzadeh, M; Alikhah, H; Zareh, A G A

    2010-02-15

    This study aimed at comparing the bone scan and CA15-3 titer in patients with breast cancer for evaluation of bone metastasis. Thirty five patients with definite diagnosis of breast cancer were evaluated in Tabriz Imam Khomeini Hospital from 2007 to 2008. Bone scan (99 mTc-MDP) performed in all patients. The serum CA15-3 was measured by ECLIA method. The increased level was considered as >30 U mL(-1). The serum level of CA15-3 was compared between the patients with and without bone metastasis, as well as its correlation with the extent of bone involvement. Thirty five patients with the mean age of 51.69 +/- 10.77 (34-81) years were enrolled in the study. According to bone scan results, 24 (68.8%) patients revealed bone metastasis. The mean level of serum CA15-3 was significantly higher in patents with bone metastasis than patients without metastasis (26.37 +/- 4.74 U mL(-1) vs. 19.09 +/- 1.99 U mL(-1); p<0.001). There was not significant relation between the serum level of CA15-3 and the extent of bone metastasis (rho = -0.063, p = 0.769). Coordinates of the curve study yielded a cut-off point > 21.8 U mL(-1) for the serum level of CA15-3 in our patients, with a sensitivity and specificity of 91.7 and 91%, respectively. Serum level of CA15-3 is higher in the patients with bone metastatic breast cancer; however, the recommended cut-off point might not be suitable for Iranian patients. Further studies with large sample sizes are recommended.

  9. Scanning electron microscopy analysis of experimental bone hacking trauma of the mandible.

    PubMed

    Alunni-Perret, Véronique; Borg, Cybèle; Laugier, Jean-Pierre; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald; Muller-Bolla, Michèle

    2010-12-01

    The authors report on a macroscopic and microscopic study of human mandible bone lesions achieved by a single-blade knife and a hatchet. The aim of this work was to complete the previous data (scanning electron microscopy analysis of bone lesions made by a single-blade knife and a hatchet, on human femurs) and to compare the lesions of the femur with those of the mandible. The results indicate that the mandible is a more fragile bone, but the features observed on the mandible are quite similar to those previously observed on the femur. This work spells out the main scanning electron microscopy characteristics of sharp (bone cutting) and blunt (exerting a pressure on the bone) mechanisms on human bone. Weapon characteristics serve to explain all of these features. PMID:20890172

  10. Scanning electron microscopy analysis of experimental bone hacking trauma of the mandible.

    PubMed

    Alunni-Perret, Véronique; Borg, Cybèle; Laugier, Jean-Pierre; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald; Muller-Bolla, Michèle

    2010-12-01

    The authors report on a macroscopic and microscopic study of human mandible bone lesions achieved by a single-blade knife and a hatchet. The aim of this work was to complete the previous data (scanning electron microscopy analysis of bone lesions made by a single-blade knife and a hatchet, on human femurs) and to compare the lesions of the femur with those of the mandible. The results indicate that the mandible is a more fragile bone, but the features observed on the mandible are quite similar to those previously observed on the femur. This work spells out the main scanning electron microscopy characteristics of sharp (bone cutting) and blunt (exerting a pressure on the bone) mechanisms on human bone. Weapon characteristics serve to explain all of these features.

  11. Scanning electron microscopy analysis of experimental bone hacking trauma.

    PubMed

    Alunni-Perret, Veronique; Muller-Bolla, Michèle; Laugier, Jean-Pierre; Lupi-Pégurier, Laurence; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald

    2005-07-01

    The authors report on their macro- and microscopy study of bone lesions made by a sharp force instrument (a single blade knife), and a sharp-blunt instrument classified as a chopping weapon (a hatchet). The aim of this work was to attempt to identify the instrument by analyzing the general class characteristics of the cuts. Each weapon was used on human bones. The results indicate that macroscopic analysis is more problematic. The microscopic analysis assessed that characteristics examined were effective in distinguishing sharp from sharp-blunt injury to the bone. The microscope facilitates analysis unachievable with macroscopic methods, some three-dimensional characteristics not visible to the naked eye being clearly defined with its use. Emphasis has been placed on the value of SEM as an anthropologist's tool in bone lesion injuries.

  12. The use of Tc-99m MDP bone scanning in the study of vascularized bone implants: concise communication

    SciTech Connect

    Dee, P.; Lambruschi, P.G.; Hiebert, J.M.

    1981-06-01

    The extent to which the nutrient artery alone is capable of maintaining bone growth in the immature animal was studied by excision and reimplantation of the upper tibia in two groups of puppies. In one group the reimplant was totally devascularized, and in a second group attempts were made to preserve the nutrient vessels to the reimplant. Technetium-99m methylene diphosphonate (Tc-99m MDP) was used to assess the effectiveness with which the nutrient circulation was maintained. With one exception the Tc-99m MDP scans proved to be reliable in indicating the potential for continued growth after reimplantation. It was found that the nutrient artery alone is capable of maintaining longitudinal bone growth in metaphyseal reimplants in immature animals. Complete devascularization results in cessation of growth. The Tc-99m MDP bone scan should prove of critical importance in the assessment of free vascularized transplants of immature bone.

  13. Fully automated shape model positioning for bone segmentation in whole-body CT scans

    NASA Astrophysics Data System (ADS)

    Fränzle, A.; Sumkauskaite, M.; Hillengass, J.; Bäuerle, T.; Bendl, R.

    2014-03-01

    Analysing osteolytic and osteoblastic bone lesions in systematically affected skeletons, e.g. in multiple myeloma or bone metastasis, is a complex task. Quantification of the degree of bone destruction needs segmentation of all lesions but cannot be managed manually. Automatic bone lesion detection is necessary. Our future objective is comparing modified bones with healthy shape models. For applying model based strategies successfully, identification and position information of single bones is necessary. A solution to these requirements based on bone medullary cavities is presented in this paper. Medullary cavities are useful for shape model positioning since they have similar position and orientation as the bone itself but can be separated more easily. Skeleton segmentation is done by simple thresholding. Inside the skeleton medullary cavities are segmented by a flood filling algorithm. The filled regions are considered as medullary cavity objects. To provide automatic shape model selection, medullary cavity objects are assigned to bone structures with pattern recognition. To get a good starting position for shape models, principal component analysis of medullary cavities is performed. Bone identification was tested on 14 whole-body low-dose CT scans of multiple myeloma patients. Random forest classification assigns medullary cavities of long bones to the corresponding bone (overall accuracy 90%). Centroid and first principal component of medullary cavity are sufficiently similar to those of bone (mean centroid difference 21.7 mm, mean difference angle 1.54° for all long bones of one example patient) and therefore suitable for shape model initialization. This method enables locating long bone structures in whole-body CT scans and provides useful information for a reasonable shape model initialization.

  14. Radiation-induced osteosarcoma might mimic metastatic bone lesions: a case with bone scan and FDG PET/CT imaging.

    PubMed

    Koyama, Masamichi; Koizumi, Mitsuru; Umayahara, Kenji; Takeshima, Nobuhiro; Takahashi, Shunji

    2015-05-01

    We report on a 53-year-old woman with osteosarcoma of the skull who underwent radiation therapy for metastatic brain tumor. She had a history of uterine endometrial cancer treated with chemotherapy and surgery 9 years previously. FDG PET/CT for surveillance showed nodular accumulation at the right suprainguinal region and very avid accumulation at the left side of the occipital bone. Bone scan showed increased accumulation at the same portion of the occipital bone. The occipital tumor was surgically removed and diagnosed as radiation-induced osteosarcoma.

  15. The clinical significance of radionuclide bone and gallium scanning in osteomyelitis of the head and neck

    SciTech Connect

    Noyek, A.M.; Kirsh, J.C.; Greyson, N.D.; Wortzman, G.; Jazrawy, H.; Freeman, J.L.; Blair, R.L.; Chapnik, J.S.

    1984-05-01

    Osteomyelitis of the head and neck remains a difficult clinical problem both in diagnosis and treatment evaluation. The purpose of this manuscript is to review our clinical experience with 25 cases of osteomyelitis distributed evenly among the temporal bone and skull base, the paranasal sinuses, and the mandible. Radionuclide bone and gallium scan images accurately depicted the biologic activity of the disease process and permitted accurate treatment evaluation and patient monitoring. This work demonstrates the potentials and limitations of radionuclide imaging with bone and gallium scan agents and attempts to define a role for their contemporary use in the management of osteomyelitis of the head and neck.

  16. Bone scanning in assessing viability of vascularized skeletal tissue transplants. [Rats

    SciTech Connect

    Lipson, R.A.; Dief, H.; Greyson, N.D.; Kawano, H.; Gross, A.E.; Langer, F.; Halloran, P.F.

    1981-01-01

    One hundred and eight bone scans using /sup 99m/Technetium methylene diphosphonate (MDP) were performed in rats undergoing vascularized and nonvascularized syngeneic and allogeneic transplants of the hind limb, and in control animals. A six-level system of grading the radionuclide uptake in the graft was used to evaluate healing or complications of the transplantation. Bone scanning was superior to other modalities in assessing viability of the graft. Bone scans were able to: (1) immediately confirm vascular patency, thus obviating angiography; (2) demonstrate differences in the rate of repair in syngeneic and allogeneic nonvascularized grafts; (3) sequentially assess vascularized allograft rejection; and (4) document long-term effects, such as bone atrophy due to disuse and early epiphyseal maturity.

  17. Technetium 99m-methylene diphosphonate bone scans in children with reflex neurovascular dystrophy

    SciTech Connect

    Laxer, R.M.; Allen, R.C.; Malleson, P.N.; Morrison, R.T.; Petty, R.E.

    1985-03-01

    Eleven children with reflex neurovascular dystrophy were investigated by technetium-labeled methylene diphosphonate bone scanning. Eight of 12 scans demonstrated abnormal findings, four showing diffusely decreased uptake and four diffusely increased uptake of the radionuclide in the affected site. Three scans showed normal findings initially, as did one previously abnormal scan when repeated in the asymptomatic patient 6 months later. Diffusely abnormal findings can be helpful in the diagnosis of childhood reflex neurovascular dystrophy, but a normal scan does not exclude the diagnosis.

  18. Evaluation of bone-marrow scanning with technetium-99m sulfur colloid in pediatric oncology.

    PubMed

    Siddiqui, A R; Oseas, R S; Wellman, H N; Doerr, D R; Baehner, R L

    1979-05-01

    Eighty-six technetium-99m sulfur colloid (Tc-SC) bone-marrow scans in 56 pediatric oncology patients were reviewed. The distribution of the sulfur colloid was similar to that in adult bone marrow in normal children older than 10 yr, and involved progressively more marrow of the extremities in normal children under 10 years of age. After irradiation or chemotherapy there was an extension of the Tc-SC to peripheral marrow sites. There was also diminished uptake of the tracer in sites corresponding to irradiated areas. In most patients there was recovery of these defects by 6 mo after completion of therapy. Tumor replacement of the marrow was reflected in the scans, and the extent of the scan defect paralleled the course of the disease. In four patients, despite normal bone scans and radiographs, marrow-scan abnormalities due to tumor replacement were present and confirmed by needle aspiration and/or biopsy. In two other patients, the marrow-scan abnormality preceded radiographic and histologic evidence of tumor metastasis. Two patients who responded clinically showed persistent defects; biopsy in one revealed fibrosis. Technetium-99m sulfur colloid bone-marrow scanning appears to be a sensitive monitor of marrow alteration caused by metastases, irradiation damage, or tissue fibrosis in children receiving treatment for cancer.

  19. Technetium Tc 99m diphosphonate bone scan. False-normal findings in elderly patients with hematogenous vertebral osteomyelitis

    SciTech Connect

    Schlaeffer, F.; Mikolich, D.J.; Mates, S.M.

    1987-11-01

    Hematogenous osteomyelitis is usually diagnosed by an abnormal technetium Tc 99m diphosphonate bone scan in symptomatic patients who have positive blood cultures. False-normal 99mTc bone scans have been described recently in neonates with biopsy-proved osteomyelitis. This phenomenon seems to be extremely rare in adults. Two elderly patients with hematogenous vertebral osteomyelitis had normal technetium Tc 99m diphosphonate bone scans when first evaluated. In both cases the bone scans became abnormal four to six weeks after onset of symptoms and two to four weeks after the initial normal results of the study. When suggested by the clinical picture, hematogenous osteomyelitis cannot be ruled out by a normal 99mTc bone scan at any age. Gallium scan, computed tomographic scan, or bone biopsy can be helpful in such cases.

  20. The use of dynamic bone scanning in the evaluation of wrist and hand pain

    SciTech Connect

    Gandsman, E.J.; Deutsch, S.D.; Catalozzi, K.; Herndon, J.

    1984-01-01

    Twenty-seven patients with complaints of wrist and/or hand pain were evaluated using a quantitative technique of dynamic (blood flow analysis) and static bone scan. The patients were divided in two groups according to their clinical history. Group A included 13 patients with a history of trauma. Seven patients had scaphoid fracture and 6 of them were scanned to determine non-union and/or avascular necrosis of the joint. One patient was scanned to determine the viability of a graft for non-union fracture. In all cases the scan gave a correct diagnosis as confirmed by later x-ray changes. Six patients in this group had negative x-rays. The scan demonstrated 4 cases of occult fractures, 4 had early Kienbock's Disease (KD) and 1 a soft tissue tumor. Group B included 14 patients with no known history of trauma. Nine had positive x-rays including 3 with KD that were scanned to determine their viability for surgical replacement of the lunate. The scan could distinguish between isolated involvement of the lunate and secondary degenerative changes of the surrounding carpal bones and radiocarpal joint. Two patients with tumor were correctly diagnosed by the scan, one as benign and one malignant. Four other patients with nonspecific changes on x-ray showed early arthritis (3 cases) and a cyst of the triquetrum ( 1 case) on the bone scan. Four patients in Group B had negative x-rays and the scan showed degenerative changes (3 cases) and an occult fracture of the hamate (1 case). The use of dynamic and static bone scanning appears to be a very valuable technique in the evaluation of patients with wrist and hand pain.

  1. Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bone

    SciTech Connect

    Conklin, J.J.; Alderson, P.O.; Zizic, T.M.; Hungerford, D.S.; Densereaux, J.Y.; Gober, A.; Wagner, H.N.

    1983-04-01

    A prospective study of bone scanning for detection of ischemic necrosis of bone (INB) was performed in 36 patients (97% female, age range 16-36 yrs.) with systemic lupus erythematosis (SLE). Since the hips, knees, and shoulders are usually affected by INB in patients with SLE, 300 K converging collimator images of these joints were obtained on film and in digital format 2 to 3 hours after the injection of 20 mCi (740 MBq) of Tc-99m methylene diphosphonate. All patients underwent radiography of the joints, and 10 had intraosseous pressure determinations in the marrow space of affected joints (n . 31) for independent assessment of INB. Scans showed abnormally increased joint activity in 28 of the 36 patients. A total of 97 joints showed abnormalities, 19% in the hips, 34% in the knees, and 47% in the shoulders. Twenty-four of 27 joints with elevated bone marrow pressure (BMP) had abnormal scans (sensitivity . 89%), and scans were abnormal in 2 of 4 joints with normal pressures (specificity . 50%). The positive predictive value of the scans compared with BMP measurements was 92% (24/26). Eleven of 27 joints with abnormal BMP had abnormal radiographs, a sensitivity of 41%.

  2. Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bone

    SciTech Connect

    Conklin, J.J.; Alderson, P.O.; Zizic, T.M.; Hungerford, D.S.; Densereaux, J.Y.; Gober, A.; Wagner, H.N.

    1983-04-01

    A prospective study of bone scanning for detection of ischemic necrosis of bone (INB) was performed in 36 patients (97% female, age range 16-36 yrs.) with systemic lupus erythematosis (SLE). Since the hips, knees, and shoulders are usually affected by INB in patients with SLE, 300 K converging collimator images of these joints were obtained on film and in digital format 2 to 3 hours after the injection of 20 mCi (740 MBq) of Tc-99m methylene diphosphonate. All patients underwent radiography of the joints, and 10 had intraosseous pressure determinations in the marrow space of affected joints (n=31) for independent assessment of INB. Scans showed abnormally increased joint activity in 28 of the 36 patients. A total of 97 joints showed abnormalities, 19% in the hips, 34% in the knees, and 47% in the shoulders. Twenty-four of 27 joints with elevated bone marrow pressure (BMP) had abnormal scans (sensitivity = 89%), and scans were abnormal in 2 of 4 joints with normal pressures (specificity = 50%). The positive predicitive value of the scans compared with BMP measurements was 92% (24/26). Eleven of 27 joints with abnormal BMP had abnormal radiographs, a sensitivity of 41%.

  3. Doctors Should Bone Up on CT Scan Cancer Risks

    MedlinePlus

    ... Medicine. For the study, the researchers surveyed doctors, radiologists and imaging technologists about radiation exposure from CT scans. They found the vast majority knew that one abdominal-pelvic CT increases patients' risk for cancer. But many didn't know how the dose ...

  4. Negative bone scans of joints after aspiration or arthrography: experimental studies.

    PubMed

    Traughber, P D; Manaster, B J; Murphy, K; Alazraki, N P

    1986-01-01

    It has long been suspected anecdotally that needle aspiration or contrast arthrogram before bone scan may cause a false-positive bone scan. This dictum often directs the sequence of events in the clinical workup of joint disease, yet data to support or refute this are lacking. This study was undertaken to generate such data. Fifty-six joints in mature dogs were examined, including hips, knees, elbows, and shoulders. The joints were examined in pairs; one joint was injected with Conray 60 for an arthrogram, and the contralateral joint was injected with an equal volume of normal saline to simulate a joint aspiration. Confirmation of needle placement and injection into the joints was made with fluoroscopic and digital subtraction imaging. Numbers of attempts required for aspiration and quantity of contrast material extravasated were noted for each joint. Baseline 99mTc-HDP or 99mTc-MDP bone scans were done before the experimental joint aspirations, with follow-up scans at 24 and 96 hr. The scans showed no significant change from baseline after either needle aspiration or arthrogram. When the diagnostic workup suggests the need for such a procedure, it should be performed. In contradiction to popular belief, joint aspiration and/or arthrogram did not affect a subsequent bone scan. PMID:3484417

  5. Bone and gallium scanning in the pre-op evaluation of the infected dysvascular foot

    SciTech Connect

    Stewart, C.; Sakimura, I.; Dillon, A.; Siegel, M.E.

    1984-01-01

    The purpose of this study is to determine the value of bone and gallium scans in predicting healing levels in the dysvascular foot with an infection requiring amputation. Healing requires amputation at a level both free of infection and with adequate blood flow. Forty-one such patients had bone and gallium scans and Doppler studies prior to amputation at a level selected by the surgeon. Eight patients required multiple surgeries before healing was obtained. Bone and soft tissue infections were determined from scans and healing levels predicted (SPHL) as the most distal amputation level free from infection: toectomy, Reye's, transmetatarsal, calcanectomy, Syme's, below knee. Doppler healing levels (DPHL) were predicted using a standard ischemic index. Doppler alone predicted the final healing level (FHL) in 41% with 59% needing more proximal amputation. Scans alone predicted FHL in 64% with 26% needing more proximal amputation. Ten percent were distal to the SPHL and all healed. These scans showed infection at transition sites between amputation levels, and the more proximal level had been predicted. Using the more proximal of the DPHL and SPHL the FHL was predicted in 78% with another 12% having more proximal amputation for nursing reasons. In 10% amputation was performed between DPHL and SPHL or at the more distal level. In no case was successful surgery performed distal to the more distal SPHL or DPHL. Bone and gallium scans used with Doppler studies are useful in optimizing the choice of amputation level in the infected, dysvascular foot.

  6. Occult gastric bleeding demonstrated by bone scan and Tc-99m-DTPA renal scan

    SciTech Connect

    Lee, V.W.; Leiter, B.E.; Weitzman, F.; Shapiro, J.H.

    1981-10-01

    A patient is described who had coagulopathy and clinically intermittent gastrointestinal bleeding. The bleeding site was clearly shown on renal and bone imaging performed at a time when the patient was considered clinically to have stopped bleeding. A bleeding gastric ulcer was subsequently demonstrated by radionuclide and contrast angiography, and at surgery.

  7. Correlative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections

    PubMed Central

    Giannini, C.; Siliqi, D.; Bunk, O.; Beraudi, A.; Ladisa, M.; Altamura, D.; Stea, S.; Baruffaldi, F.

    2012-01-01

    Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon resolution. This favorable combination has been applied for the first time to biopsies of dwarfism syndrome and Paget's disease to shed light onto the cortical structure of natural bone in healthy and pathologic sections. PMID:22666538

  8. Precision of cortical bone reconstruction based on 3D CT scans.

    PubMed

    Wang, Jianping; Ye, Ming; Liu, Zhongtang; Wang, Chengtao

    2009-04-01

    The precision and accuracy of human cortical bone reconstruction using 3D CT scans was evaluated using machined bone segments. Both linear and angular errors were measured. Cadaver adult femoral and tibial cortical bone segments were obtained and machined in six orthogonal planes with a precision milling machine. CT scans were then obtained and the bone segments were reconstructed as digital replicas. Dimensional and angular measurements errors were evaluated for the machined bone segments and the results were compared with known dimensions based on milling machine settings to calculate errors due to scanning and model reconstruction. The model dimensional error in the coronal, sagittal and axial directions had a mean of 0.21 mm, with standard a deviation of 0.12 mm and a maximum error of 0.47 mm. The mean percent error was 0.74% and the maximum percent error was 1.9%. The angular error of models in the coronal, sagittal and axial directions was calculated, yielding a mean of 0.47 degrees with a standard deviation of 0.37 degrees and a maximum of 1.33 degrees. The error in the cross-sectional axial direction had a mean of 0.54 mm with a maximum error of 0.83 mm, depending on the slice interval. The main error source was of the image processing, which was about 70% of the total error. We found that machining cortical bone segments prior to CT scanning is an effective method for accuracy evaluation of CT-based bone reconstruction. This method can provide a reference for assessing the sensitivity, reliability and accuracy of CT-based applications in the study of movement, finite element modeling, and prosthesis construction.

  9. Technetium-99m APD compared with technetium-99m MDP as a bone scanning agent

    SciTech Connect

    Degrossi, O.J.; Oliveri, P.; Garcia del Rio, H.; Labriola, R.; Artagaveytia, D.; Degrossi, E.B.

    1985-10-01

    The authors have investigated the possibilities of technetium-99m-(-3-aminohydroxypropylidene)-1-1-bisphosphonate ((/sup 99m/Tc)APD) as a bone scanning agent in 14 normal subjects and 28 patients. Similar studies in the same normal subjects and patients were carried out with /sup 99m/Tc-methylene-bisphosphonate ((/sup 99m/Tc)MDP). The compounds were labeled with /sup 99m/Tc by means of an electrolytical method; the free pertechnetate content was always under 1%. The (/sup 99m/Tc)APD T1/2 of the third component of the disappearance plasma curve in six normal subjects was 152 +/- 46 min (mean +/- s.d.), while the 24-hr whole-body retention (WBR) was 17.6% +/- 4.6. The (99mTc)MDP value of the 24-hr WBR was 28.6% +/- 3.9. The bone/soft-tissue ratio (B/ST) was investigated in eight control subjects on the eleventh thoracic and the fourth lumbar vertebrae. The B/ST ratios were similar for both APD and MDP studies. In 28 patients with suspected bone metastasis or primary bone disease, bone scintigraphy was carried out; both compounds showed similar findings and the same number of positive results. In five of these patients, the lesion/normal bone ratio was determined with values of 4.6 +/- 2.0 in APD studies and 4.8 +/- 2.3 with MDP. APD was also used in 126 patients; no adverse reactions were observed. The APD dose used i.v. for bone scanning was 200-fold less than those employed by mouth per day, for the treatment of bone disease for long periods. In our experience, APD appears to be an adequate agent for bone scintigraphy.

  10. Circulation, bone scans, and tetracycline labeling in microvascularized and vascular bundle implanted rib grafts

    SciTech Connect

    Lalonde, D.H.; Williams, H.B.; Rosenthall, L.; Viloria, J.B.

    1984-11-01

    The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized rib grafts and of implanted vascular bundles. In contrast, tetracycline labeling was repeatedly observed in avascular areas of bone grafts and, therefore, is not a reliable indicator of bone graft circulation.

  11. Three-dimensional assessment of bone turnover using computed microtomography and laser-scanning confocal microscopy

    NASA Astrophysics Data System (ADS)

    Prevrhal, Sven; Jiang, Yebin; Zhao, Jenny; Genant, Harry K.

    2000-06-01

    Objective: Metabolic activity in trabecular bone is an important indicator in the therapy of bone diseases like osteoporosis. It is reflected by the amount of osteoid (young, not yet mineralized bone) and young calcified tissue (YCT). Our aim was to replace standard 2D histomorphometry with a 3D approach for osteoid and YCT measurement. Measurement Methods: Excised lumbar vertebrae of 5 ovariectomized (OVX) and 5 control rats were 3D-scanned with computed micro-tomography ((mu) CT, isotropic spatial resolution 20 micrometer3) and laser scanning confocal microscopy (LSCM, 20X magnification, 1X1X2 micrometer3 spatial resolution). (mu) CT shows trabecular bone structure; LSCM shows osteoid and YCT by fluorescent light. Image Processing Methods: The fraction of bone to tissue volume (BV/TV) and the number of trabeculae (Tb.N) were calculated from globally thresholded (mu) CT images. LSCM images were enhanced using top-hat transform, globally thresholded and morphologically closed. Separate regions were labeled by volume growing. We measured feature volume to background volume ratio and number of features per unit volume. Results and Conclusions: In the specimens obtained from the OVX rats, a significant increase in the volume fractions of osteoid and YCT could be seen. The (mu) CT-LSCM approach presents a significant improvement over time-consuming, standard histomorphometry. The image processing for both modalities could be achieved automatically.

  12. The role of angular reflection in assessing elastic properties of bone by scanning acoustic microscopy.

    PubMed

    Puchegger, S; Fix, D; Pilz-Allen, C; Roschger, P; Fratzl, P; Weinkamer, R

    2014-01-01

    For an assessment of the mechanical performance of bone, a quantitative description of its mechanical heterogeneity is necessary. Previously, scanning acoustic microscopy (SAM) was used as a non-destructive method to estimate bone stiffness on the micrometer scale. While up to now only the normal incidence of acoustic waves is taken into account, we extend in our study the evaluation procedure by considering the full opening of the acoustic lens. The importance of this technical aspect is demonstrated by determining the contrast in Young's modulus between newly formed osteons and the surrounding higher mineralized interstitial bone. Several regions of human cortical bone of a femur in cross-section were imaged. For all the regions quantitative backscattered-electron imaging (qBEI) to estimate the local mass density was combined with SAM measurements. These measurements reveal a non-monotonic dependence between acoustic reflectivity and Young's modulus, which shows that it is actually necessary to consider the lens opening in a quantitative way. This problem was experimentally and theoretically approached by using lenses with two different opening angles operated at different frequencies (52° at 400MHz and 80° at 820MHz) to image the same specimen. The mass density of bone in osteons was found to be 1930kg/m(3) on average, while the higher mineral content in interstitial bone results in a 9% increase of the density. The contrast in the effective Young's modulus E, as determined through SAM, is more pronounced, with an average value of 14GPa in osteons and a more than 60% increase in interstitial bone. Additionally, SAM maps show oscillations in E with a periodicity of the typical bone lamella thickness of approximately 7µm in both osteons and interstitial bone. This mechanical heterogeneity can be explained by the varying orientation of the mineralized collagen fibers.

  13. Spleen Uptake on Bone Scan After Frequent Platelet and RBC Transfusions.

    PubMed

    De Marini, Pierre; Laplace, Annegret; Matuszak, Julien; Fornecker, Luc-Matthieu; Namer, Izzie Jacques

    2016-10-01

    A 21-year-old man, allogeneic hematopoietic stem cell transplantation recipient, was referred to our nuclear medicine department for a suspicion of knee osteonecrosis. Bone scan with Tc-HMDP did not show abnormal bone uptake but an intense spleen accumulation. F-FDG PET/CT performed on the same day showed no pathological spleen uptake. The patient had secondary hemochromatosis resulting from frequent transfusions in the setting of a chronic graft versus host disease with hemolysis and thrombocytopenia. The last RBC and platelet transfusions were performed 9 and 2 days before the examination, respectively. Secondary hemochromatosis and recent transfusions may explain our findings.

  14. Numb chin syndrome as a manifestation of jaw metastasis diagnosed in a bone scan.

    PubMed

    Noriega, E; Sabaté-Llobera, A; Benítez, A; Martínez, G A; Rodríguez-Rubio, J; Mora, J

    2016-01-01

    In many cases, numb chin syndrome (NCS) may represent a banal pathology. However, as it can be associated with malignant processes, its presence should alert the clinician of a possible occult disease. In patients already diagnosed with cancer, it often represents an ominous sign that indicates poor prognosis, due to the rapid progress of the disease. The case is presented of a 62-year-old man diagnosed with synchronous lung and bladder cancer, who suddenly complained of numbness in the chin. The bone scan confirmed the suspicion of metastastic bone disease, and the patient died two months after the appearance of this sign.

  15. Scanning electron microscope studies of bone samples: Influence of simulated microgravity

    NASA Astrophysics Data System (ADS)

    Mehta, Rahul; Chowdhury, Parimal; Ali, Nawab

    2007-08-01

    A scanning electron microscope (SEM) with backscatter and secondary electron emission detectors plus a Si(Li) detector for photon yield measurements was used to study bone samples from skull and leg of mice and rats. These animals were either suspended by their tail to induce simulated microgravity, characterized as hind-limb suspension (HLS) or not suspended (control). Analyses of the SEM images and energy dispersive spectrometer (EDS) spectra using Si(Li) detector indicate variation in the lattice structures, and in intensities of the characteristics X-rays, produced from the exposed bone surface due to its interaction with the electron beam. Using Flame software, the X-ray spectra were analyzed and normalized ratios of the elements determined. The elemental analysis indicated a variation in the density of calcium, potassium, and oxygen near the knee joints and near the sutures in the skull bones. The comparison of simulated microgravity subjected samples of the rat skull bones with that of the control samples revealed that in the suture region there was a large increase in the ratio of calcium, and to some degree for phosphorus, suggesting simulated microgravity affects distribution of these elements. Elemental composition for control samples with depth (within the cross section of the leg bones) revealed decrease of oxygen and increase of calcium in the first millimeter of the bone depth after which the relative percentage of elements stayed constant.

  16. Bone scan

    MedlinePlus

    ... must have the test while breastfeeding, you should pump and throw away the breast milk for the next 2 days. The amount of radiation injected into your vein is very small. All radiation is gone from the body within ...

  17. The Angle of Louis. A potential pitfall (''Louie's Hot Spot'') in bone scan interpretation

    SciTech Connect

    Fink-Bennett, D.M.; Shapiro, E.E.

    1984-06-01

    Evaluation of 100 consecutive Tc-99m MDP bone scans revealed in 36 patients a well defined area of increased accumulation of radiotracer at the Angle of Louis--the palpable ridge along the anterior surface of the sternum at the fibrocartilaginous junction of the sternum and manubrium. Twenty-five of the 36 patients had comparison radiographs; all were normal. None had sternal pain or a prior history of chest trauma. Increased uptake at the Angle of Louis (''Louie's Hot Spot'') is a relatively common finding (36%) and should be recognized as a normal bone scan finding. It should not be confused with increased uptake due to an osseous abnormality, i.e., metastasis, degenerative disease, trauma, etc.

  18. Bone scanning with 99mtechnetium phosphate to assess condylar hyperplasia. Report of two cases.

    PubMed

    Matteson, S R; Proffit, W R; Terry, B C; Staab, E V; Burkes, E J

    1985-10-01

    Condylar hyperplasia poses a problem in planning treatment because it is a self-limiting process for some but not all patients. Continued growth creates a progressive deformity that requires condylectomy, whereas an enlarged condyle can be left in place after hyperplastic growth ceases, even if ramus surgery is needed to correct asymmetry. Bone scan with 99mtechnetium phosphate can be used to assist in making the differential diagnosis. In the two patients reported here, abnormal metabolic activity revealed by bone scans supported clinical and historical evidence that the condylar hyperplasia was active and required surgical correction, including condylectomy. The two cases demonstrate different approaches to postsurgical orthodontic treatment, depending on the amount of normal growth expected. PMID:3864094

  19. Friend or foe: high bone mineral density on routine bone density scanning, a review of causes and management

    PubMed Central

    Hardcastle, Sarah A.; Cooper, Cyrus; Tobias, Jonathan H.

    2013-01-01

    A finding of high BMD on routine DXA scanning is not infrequent and most commonly reflects degenerative disease. However, BMD increases may also arise secondary to a range of underlying disorders affecting the skeleton. Although low BMD increases fracture risk, the converse may not hold for high BMD, since elevated BMD may occur in conditions where fracture risk is increased, unaffected or reduced. Here we outline a classification for the causes of raised BMD, based on identification of focal or generalized BMD changes, and discuss an approach to guide appropriate investigation by clinicians after careful interpretation of DXA scan findings within the context of the clinical history. We will also review the mild skeletal dysplasia associated with the currently unexplained high bone mass phenotype and discuss recent advances in osteoporosis therapies arising from improved understanding of rare inherited high BMD disorders. PMID:23445662

  20. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    NASA Astrophysics Data System (ADS)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  1. Correction of step artefact associated with MRI scanning of long bones.

    PubMed

    Rathnayaka, Kanchana; Cowin, Gary; Schuetz, Michael A; Sahama, Tony; Schmutz, Beat

    2013-07-01

    3D models of long bones are being utilised for a number of fields including orthopaedic implant design. Accurate reconstruction of 3D models is of utmost importance to design accurate implants to allow achieving a good alignment between two bone fragments. Thus for this purpose, CT scanners are employed to acquire accurate bone data exposing an individual to a high amount of ionising radiation. Magnetic resonance imaging (MRI) has been shown to be a potential alternative to computed tomography (CT) for scanning of volunteers for 3D reconstruction of long bones, essentially avoiding the high radiation dose from CT. In MRI imaging of long bones, the artefacts due to random movements of the skeletal system create challenges for researchers as they generate inaccuracies in the 3D models generated by using data sets containing such artefacts. One of the defects that have been observed during an initial study is the lateral shift artefact occurring in the reconstructed 3D models. This artefact is believed to result from volunteers moving the leg during two successive scanning stages (the lower limb has to be scanned in at least five stages due to the limited scanning length of the scanner). As this artefact creates inaccuracies in the implants designed using these models, it needs to be corrected before the application of 3D models to implant design. Therefore, this study aimed to correct the lateral shift artefact using 3D modelling techniques. The femora of five ovine hind limbs were scanned with a 3T MRI scanner using a 3D vibe based protocol. The scanning was conducted in two halves, while maintaining a good overlap between them. A lateral shift was generated by moving the limb several millimetres between two scanning stages. The 3D models were reconstructed using a multi threshold segmentation method. The correction of the artefact was achieved by aligning the two halves using the robust iterative closest point (ICP) algorithm, with the help of the overlapping

  2. Microwave bone imaging: a preliminary scanning system for proof-of-concept

    PubMed Central

    Cuccaro, Antonio; Solimene, Raffaele; Brancaccio, Adriana; Basile, Bruno; Ammann, Max J.

    2016-01-01

    This Letter introduces a feasibility study of a scanning system for applications in biomedical bone imaging operating in the microwave range 0.5–4 GHz. Mechanical uncertainties and data acquisition time are minimised by using a fully automated scanner that controls two antipodal Vivaldi antennas. Accurate antenna positioning and synchronisation with data acquisition enables a rigorous proof-of-concept for the microwave imaging procedure of a multi-layer phantom including skin, fat, muscle and bone tissues. The presence of a suitable coupling medium enables antenna miniaturisation and mitigates the impedance mismatch between antennas and phantom. The three-dimensional image of tibia and fibula is successfully reconstructed by scanning the multi-layer phantom due to the distinctive dielectric contrast between target and surrounding tissues. These results show the viability of a microwave bone imaging technology which is low cost, portable, non-ionising, and does not require specially trained personnel. In fact, as no a-priori characterisation of the antenna is required, the image formation procedure is very conveniently simplified. PMID:27733930

  3. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    PubMed Central

    2011-01-01

    Purpose This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement. PMID:21977476

  4. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    NASA Astrophysics Data System (ADS)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  5. The os trigonum syndrome: use of bone scan in the diagnosis.

    PubMed

    Johnson, R P; Collier, B D; Carrera, G F

    1984-08-01

    The os trigonum is an accessory bone of the foot found in 7% of the normal adult population. It is located at the posterolateral projection of the talus, and can occasionally give rise to symptoms of acute and chronic unexplained ankle pain. We report three patients, one with acute fracture and two with chronic ankle symptoms. Technetium 99 methylene diphosphonate showed intense focal uptake at the posterior talus pointing to the os trigonum as the site of symptoms. It was excised in two patients with complete relief. The third went on to develop an asymptomatic nonunion. We recommend bone scanning as a procedure that is helpful in delineating obscure pain in the ankle that may be due to chronic irritative nonunion of the os trigonum.

  6. Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

    SciTech Connect

    Straten, Marcel van; Schaap, Michiel; Dijkshoorn, Marcel L.; Greuter, Marcel J.; Lugt, Aad van der; Krestin, Gabriel P.; Niessen, Wiro J.

    2011-11-15

    Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration

  7. SCAN+

    SciTech Connect

    Kenneth Krebs, John Svoboda

    2009-11-01

    SCAN+ is a software application specifically designed to control the positioning of a gamma spectrometer by a two dimensional translation system above spent fuel bundles located in a sealed spent fuel cask. The gamma spectrometer collects gamma spectrum information for the purpose of spent fuel cask fuel loading verification. SCAN+ performs manual and automatic gamma spectrometer positioning functions as-well-as exercising control of the gamma spectrometer data acquisitioning functions. Cask configuration files are used to determine the positions of spent fuel bundles. Cask scanning files are used to determine the desired scan paths for scanning a spent fuel cask allowing for automatic unattended cask scanning that may take several hours.

  8. Radionuclide bone scanning in neuroblastoma: skeletal metastases and primary tumor localization of /sup 99m/Tc-MDP

    SciTech Connect

    Podrasky, A.E.; Stark, D.D.; Hattner, R.S.; Gooding, C.A.; Moss, A.A.

    1983-09-01

    Of 42 radionuclide bone scans in 35 children with neuroblastoma, 21 were abnormal for the presence of skeletal metastases. Of the 21 abnormal scans, 16 were corroborated by positive bone-marrow biopsy or clinical data. The false-negative and false-positive rates for bone scanning were 4.8% and 9.5%, respectively. Calcification of the primary tumor was seen on pretreatment computed tomographic (CT) scans in 24 (89%) of 27 cases, while only 13 (48%) of 27 were detectable by plain radiographs. Uptake of /sup 99m/Tc methylene diphosphate /sup 99m/Tc-MDP) by the primary tumor occurred in 20 of 27 cases, but correlation between tumor uptake and calcification was not statistically significant. All children with markedly elevated urinary vanillylmandelic acid exhibited primary tumor uptake. Survival was not affected independently by primary tumor uptake.

  9. Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans

    SciTech Connect

    Shiraishi, Junji; Li Qiang; Appelbaum, Daniel; Pu Yonglin; Doi, Kunio

    2007-01-15

    Bone scintigraphy is the most frequent examination among various diagnostic nuclear medicine procedures. It is a well-established imaging modality for the diagnosis of osseous metastasis and for monitoring osseous tumor response to chemotherapy and radiation therapy. Although the sensitivity of bone scan examinations for detection of bone abnormalities has been considered to be relatively high, it is time consuming to identify multiple lesions such as bone metastases of prostate and breast cancers. In addition, it is very difficult to detect subtle interval changes between two successive abnormal bone scans, because of variations in patient conditions, the accumulation of radioisotopes during each examination, and the image quality of gamma cameras. Therefore, we developed a new computer-aided diagnostic (CAD) scheme for the detection of interval changes in successive whole-body bone scans by use of a temporal subtraction image which was obtained with a nonlinear image-warping technique. We carried out 58 pairs of successive bone scans in which each scan included both posterior and anterior views. We determined 107 'gold-standard' interval changes among the 58 pairs based on the consensus of three radiologists. Our computerized scheme consisted of seven steps, i.e., initial image density normalization on each image, image matching for the paired images, temporal subtraction by use of the nonlinear image-warping technique, initial detection of interval changes by use of temporal-subtraction images, image feature extraction of candidates of interval changes, rule-based tests by use of 16 image features for removing some false positives, and display of the computer output for identified interval changes. One hundred seven gold standard interval changes included 71 hot lesions (uptake was increased compared with the previous scan, or there was new uptake in the current scan) and 36 cold lesions (uptake was decreased or disappeared) for anterior and posterior views. The

  10. SCAN+

    2009-11-01

    SCAN+ is a software application specifically designed to control the positioning of a gamma spectrometer by a two dimensional translation system above spent fuel bundles located in a sealed spent fuel cask. The gamma spectrometer collects gamma spectrum information for the purpose of spent fuel cask fuel loading verification. SCAN+ performs manual and automatic gamma spectrometer positioning functions as-well-as exercising control of the gamma spectrometer data acquisitioning functions. Cask configuration files are used to determinemore » the positions of spent fuel bundles. Cask scanning files are used to determine the desired scan paths for scanning a spent fuel cask allowing for automatic unattended cask scanning that may take several hours.« less

  11. Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

    NASA Technical Reports Server (NTRS)

    Whalen, Robert T.; Napel, Sandy; Yan, Chye H.

    1996-01-01

    Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

  12. [Bone scanning with sodium 18F-fluoride PET and PET/CT. German guideline Version 1.0.].

    PubMed

    Hellwig, D; Krause, B-J; Schirrmeister, H; Freesmeyer, M

    2010-01-01

    In nuclear medicine, bone scanning is based on the principle of scintigraphy using bone-seeking radiopharmaceuticals which accumulate in sites of increased bone formation. From a historical point of view, (18)F-fluoride was one of the first osteotropic tracers which was replaced by (99m)Tc-labelled polyphosphonates. With the development of modern PET equipment the superior diagnostic performance of (18)F-fluoride PET for the detection and characterization of osseous lesions was proven in comparison to conventional bone scanning. Recently, its importance as a substitute of conventional skeletal scintigraphy increased in a time with limited availability of (99)Mo/(99m)Tc. To ensure health care during this period, (18)F-fluoride PET currently became part of common outpatient care. This guideline comprehends recommendations on indications, protocols, interpretation and reporting of (18)F-fluoride PET and PET/CT. PMID:20838734

  13. Focal spinal abnormalities on bone scans in ankylosing spondylitis: a clue to the presence of fracture or pseudarthrosis.

    PubMed

    Resnick, D; Williamson, S; Alazraki, N

    1981-05-01

    Four cases of ankylosing spondylitis are presented in which radionuclide bone studies indicated focal abnormalities of the spine. In three patients, the area of abnormal nuclide uptake corresponded to a site of pseudarthrosis, and in the fourth an acute fracture was present. As such focal lesions on bone scans are unusual in cases of chronic ankylosing spondylitis in which a complication is not apparent, their presence can be a useful finding. PMID:6262000

  14. Focal spinal abnormalities on bone scans in ankylosing spondylitis: a clue to the presence of fracture or pseudarthrosis

    SciTech Connect

    Resnick, D.; Williamson, S.; Alazraki, N.

    1981-05-01

    Four cases of ankylosing spondylitis are presented in which radionuclide bone studies indicated focal abnormalities of the spine. In three patients, the area of abnormal nuclide uptake corresponded to a site of pseudarthrosis, and in the fourth an acute fracture was present. As such focal lesions on bone scans are unusual in cases of chronic ankylosing spondylitis in which a complication is not apparent, their presence can be a useful finding.

  15. Metastatic mimics on bone scan: “All that glitters is not metastatic”

    PubMed Central

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    In this pictorial review, cases where benign diseases caused a diagnostic dilemma on bone scan are illustrated. This review highlights the value of correlative imaging- single-photon emission computed tomography/computed tomography (CT), CT, and magnetic resonance imaging in solving the diagnostic problem by exact localization and characterization of the lesions. All these eventually lead to increased diagnostic confidence, better and more accurate reporting and avoidance of delay in initiation of treatment due to equivocal results. The imaging features of these benign pathologies – which are “mimics of metastatic disease,” are elaborated so that the reader can incorporate them while reporting so as to avoid mis-interpretations. PMID:27385887

  16. Noninvasive determination of bone stiffness for distraction osteogenesis by quantitative computed tomography scans.

    PubMed

    Harp, J H; Aronson, J; Hollis, M

    1994-04-01

    Apparent density of canine tibial specimens was correlated to measured quantitative computed tomography (QCT) numbers, and a conversion equation was derived. Finite element analysis models of canine tibiae were constructed using spatial coordinates of converted QCT data. Two QCT-derived finite elemental analysis models were constructed for a pair of matched tibiae: one lengthened 15% by distraction osteogenesis and one contralateral control. Two equations relating the modulus of elasticity to apparent density were used. These models were then verified mechanically by measuring strains of the two specimens under applied load. Equation I correlated best with measured strains in the less-dense regenerate bone of the distracted tibia (R2 = 0.914, p = 0.0028, n = 6); Equation II performed best in the denser control tibia (R2 = 0.820, p = 0.0129, n = 6). These results demonstrate that the stiffness of tubular bones, including cortical and heterogenous cancellous structure, can be accurately predicted by a noninvasive QCT scan.

  17. Strontium and bone nanostructure in normal and ovariectomized rats investigated by scanning small-angle X-ray scattering.

    PubMed

    Bünger, Mathias H; Oxlund, Hans; Hansen, Toke K; Sørensen, Søren; Bibby, Bo M; Thomsen, Jesper S; Langdahl, Bente L; Besenbacher, Flemming; Pedersen, Jan S; Birkedal, Henrik

    2010-04-01

    The effect of SrCl(2) treatment on bone nanostructure in a rat ovariectomy model was studied using scanning small-angle X-ray scattering (sSAXS). Twelve 6-month-old female Wistar rats were used. Six animals were ovariectomized (+ovx) and six were left intact after sham surgery (-ovx). Six animals, three +ovx and three -ovx, were treated with 4 mmol SrCl(2) (aq)/kg/day (+Sr), whereas the remaining six received placebo (-Sr) for 140 days. Rats were labeled with flourochromes at days 7, 126, and 136. Femoral cross sections were studied using fluorescence microscopy, scanning electron microscopy including energy-dispersive X-ray analysis, and sSAXS. The SAXS data comprised about 5,500 measurements and provided information about mineral crystal thickness and orientation in new and old bone. The newly formed bone contained higher levels of Sr(2+) in +Sr than in -Sr animals, indicating that the Sr(2+) was incorporated into the new bone. Mineral plates were significantly thicker in old bone, 2.62 nm (95% CI 2.58-2.66), than in new bone, 2.41 nm (95% CI 2.36-2.46). Surprisingly, mineral plates in new bone were significantly thicker (2.52 [95% CI 2.47-2.57] nm vs. 2.41 [95% CI 2.36-2.46] nm, P = 0.017) in +ovx rats than in -ovx rats. However, no significant effect of SrCl(2) on mineral plate thicknesses in new bone was observed. The statistical model yielded estimates of the difference in bone mineral plate thickness induced by Sr. The estimated effect of Sr was -0.09 (95% CI -0.21 to 0.03) and 0.02 (95% CI -0.10 to 0.14) nm for new bone in -ovx and +ovx rats, respectively. PMID:20221590

  18. Acute hematogenous osteomyelitis: has the bone scan betrayed us. [/sup 99m/Tc-phosphate compounds; /sup 67/Ga-citrate

    SciTech Connect

    Handmaker, H.

    1980-06-01

    Technetium-99m bone scanning reveals a spectrum of findings in the diagnosis of acute hematogenous osteomyelitis. Both cold and hot abnormalities are found. Gallium-67 citrate imaging is recommended when /sup 99m/Tc phosphate scans are inconclusive.

  19. CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis

    PubMed Central

    Obert, Laurent; Peyron, Christelle; Boyer, Etienne; Menu, Gauthier; Loisel, François; Aubry, Sébastien

    2016-01-01

    Introduction: The shoulder arthroplasty brings satisfaction to patients in terms of quality of life and indolence. However whether anatomic implant or reverse, it does not escape from the loosening of the glenoid component. Moreover, optimal implantation is required to ensure the functional outcome without shortening of the arm. The purpose of this study is obtain CT scan evaluation of the glenoid bone stock in order to optimize glenoid component implantation and obtain a reference to determine optimal humeral component placement in case of humeral proximal fracture. Materials and methods: Between 2010 and 2011 we have analyzed 200 intact shoulder’s CT. We measured maximal and minimal width in the transverse plane of the glenoid, the distance from the pectoralis major (PM) tendon to the humeral head, the greater tubercle, change of curvature and the anatomical neck. Results: Mean maximum width was 27.4 ± 3.4 mm and mean minimum width was 15.5 ± 2.8 mm. Distances between upper edge of PM tendon to: humeral head, greater tubercle, change of curvature and anatomical neck were respectively: 67.6 ± 9.98 mm, 57.8 ± 10.3 mm, 28.7 ± 9 mm, and 34.2 ± 9.7 mm. Conclusion: Our study has produced an assessment of glenoid bone stock for optimal positioning of the glenoid implant but also to obtain a reference to determine the ideal location of the humeral component in the case of proximal humerus fracture. PMID:27716461

  20. Accuracy of cancellous bone volume fraction measured by micro-CT scanning.

    PubMed

    Ding, M; Odgaard, A; Hvid, I

    1999-03-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner supplied algorithm (method I). A significant deviation of volume fraction from method I was found: both the y-intercept and the slope of the regression line were significantly different from those of the Archimedes-based volume fraction (p < 0.001). New individual thresholds were determined based on a calibration of volume fraction to the Archimedes-based volume fractions (method II). The mean thresholds of the two methods were applied to segment 20 randomly selected specimens. The results showed that volume fraction using the mean threshold of method I was underestimated by 4% (p = 0.001), whereas the mean threshold of method II yielded accurate values. The precision of the measurement was excellent. Our data show that care must be taken when applying thresholds in generating 3-D data, and that a fixed threshold may be used to obtain reliable volume fraction data. This fixed threshold may be determined from the Archimedes-based volume fraction of a subgroup of specimens. The threshold may vary between different materials, and so it should be determined whenever a study series is performed. PMID:10093033

  1. Comparison of DXA Scans and Conventional X-rays for Spine Morphometry and Bone Age Determination in Children.

    PubMed

    Hoyer-Kuhn, Heike; Knoop, Kai; Semler, Oliver; Kuhr, Kathrin; Hellmich, Martin; Schoenau, Eckhard; Koerber, Friederike

    2016-01-01

    Conventional lateral spine and hand radiographs are the standard tools to evaluate vertebral morphometry and bone age in children. Beside bone mineral density analyses, dual-energy X-ray absorptiometry (DXA) measurements with lower radiation exposure provide high-resolution scans which are not approved for diagnostic purposes. Data about the comparability of conventional radiographs and DXA in children are missing yet. The purpose of the trial was to evaluate whether conventional hand and spine radiographs can be replaced by DXA scans to diminish radiation exposure. Thirty-eight children with osteogenesis imperfecta or secondary osteoporosis or short stature (male, n=20; age, 5.0-17.0 yr) were included and assessed once by additional DXA (GE iDXA) of the spine or the left hand. Intraclass correlation coefficients (ICCs) were used to express agreement between X-ray and iDXA assessment. Evaluation of the spine morphometry showed reasonable agreement between iDXA and radiography (ICC for fish-shape, 0.75; for wedge-shape, 0.65; and for compression fractures, 0.70). Bone age determination showed excellent agreement between iDXA and radiography (ICC, 0.97). IDXA-scans of the spine in a pediatric population should be used not only to assess bone mineral density but also to evaluate anatomic structures and vertebral morphometry. Therefore, iDXA can replace some radiographs in children with skeletal diseases.

  2. Evaluation of extremity pain in children using technetium-99m MDP bone scan: A general hospital experience

    SciTech Connect

    Park, H.M.; Rothschild, P.A.; Kernek, C.B.

    1984-01-01

    This study was undertaken to evaluate the efficacy of three-phase bone scan in detection of significant pathology i.e., osteomyelitis (OM), septic joint, cellulitis, etc., in children with symptoms of extremity pain. A total of 100 consecutive patients (age 9 days - 16 yrs, 63 boys and 37 girls) were studied. The authors reviewed their scans, x-rays and hospital records. The final diagnoses were based on the findings of needle aspiration, surgical drainage, biopsy, culture, and on the therapeutic response. In 87%, sufficiently long clinical follow-up was available to confirm the final diagnoses. In the remaining 13%, the symptoms resolved quickly and follow-up was not felt necessary. The scan was essential in pinpointing the lesions in pts with referred or nonlocalizing extremity pain. The +ve and -ve predictive values of the scan and OM were 89% and 96% respectively. One spiral fracture was misinterpreted as diffuse OM. One ''Subacute epiphyseal OM'' was not detected. In two cases, cellulitis and septic joint obscured underlying OM. Prior antibotic therapy resulted in one equivocal scan. Although less sensitive (29%) in early OM, radiographs play an important complimentary role. Bone scans detected underlying pathology for extremity pain in 61% of all pts studied.

  3. The nanometre-scale physiology of bone: steric modelling and scanning transmission electron microscopy of collagen-mineral structure.

    PubMed

    Alexander, Benjamin; Daulton, Tyrone L; Genin, Guy M; Lipner, Justin; Pasteris, Jill D; Wopenka, Brigitte; Thomopoulos, Stavros

    2012-08-01

    The nanometre-scale structure of collagen and bioapatite within bone establishes bone's physical properties, including strength and toughness. However, the nanostructural organization within bone is not well known and is debated. Widely accepted models hypothesize that apatite mineral ('bioapatite') is present predominantly inside collagen fibrils: in 'gap channels' between abutting collagen molecules, and in 'intermolecular spaces' between adjacent collagen molecules. However, recent studies report evidence of substantial extrafibrillar bioapatite, challenging this hypothesis. We studied the nanostructure of bioapatite and collagen in mouse bones by scanning transmission electron microscopy (STEM) using electron energy loss spectroscopy and high-angle annular dark-field imaging. Additionally, we developed a steric model to estimate the packing density of bioapatite within gap channels. Our steric model and STEM results constrain the fraction of total bioapatite in bone that is distributed within fibrils at less than or equal to 0.42 inside gap channels and less than or equal to 0.28 inside intermolecular overlap regions. Therefore, a significant fraction of bone's bioapatite (greater than or equal to 0.3) must be external to the fibrils. Furthermore, we observe extrafibrillar bioapatite between non-mineralized collagen fibrils, suggesting that initial bioapatite nucleation and growth are not confined to the gap channels as hypothesized in some models. These results have important implications for the mechanics of partially mineralized and developing tissues.

  4. [Total body MRI in early detection of bone metastasis and its indication in comparison to bone scan and other imaging techniques].

    PubMed

    Luna, Antonio; Vilanova, Joan C; Alcalá Mata, Lidia

    2015-04-01

    Bone metastases are a recognized prognostic factor in patients with prostate cancer. Currently, Tc99 bone scan is the most frequently used imaging technique for their detection, showing a high sensitivity but a limited specificity. Thus, new morphological and mainly functional imaging techniques based on PET and MRI, or hybrid techniques such as PET-CT or PET-MRI have been introduced to improve metastases detection, estimation of total tumor load and for therapeutic monitoring. In this clinical scenario, total body MRI has arisen as a very promising technique in detection and therapeutic monitoring of bone metastases of prostate cancer, because it neither uses ionizing radiation nor needs the administration of contrast media. The incorporation of MR diffusion to the morphologic total body MRI protocols provides functional information, improving the sensitivity in oncological lesions detection in general and osteolytic bone metastases of PCa in particular. Its integration in protocols with morphological sequences and its quantification through ADC maps enables us to better understand metastatic bone disease patterns and their changes with different therapies. Total body D MRI enables the early classification of the response to treatment with evident advantages over other imaging techniques and the purely morphological approach with MRI. In any case, prospective and cost-effectiveness studies are necessary to establish the role of total-body D MRI in the management of patients with PCa.

  5. When to perform positron emission tomography/computed tomography or radionuclide bone scan in patients with recently diagnosed prostate cancer.

    PubMed

    Caldarella, Carmelo; Treglia, Giorgio; Giordano, Alessandro; Giovanella, Luca

    2013-01-01

    Skeletal metastases are very common in prostate cancer and represent the main metastatic site in about 80% of prostate cancer patients, with a significant impact in patients' prognosis. Early detection of bone metastases is critical in the management of patients with recently diagnosed high-risk prostate cancer: radical treatment is recommended in case of localized disease; systemic therapy should be preferred in patients with distant secondary disease. Bone scintigraphy using radiolabeled bisphosphonates is of great importance in the management of these patients; however, its main drawback is its low overall accuracy, due to the nonspecific uptake in sites of increased bone turnover. Positron-emitting radiopharmaceuticals, such as fluorine-18-fluorodeoxyglucose, choline-derived drugs (fluorine-18-fluorocholine and carbon-11-choline) and sodium fluorine-18-fluoride, are increasingly used in clinical practice to detect metastatic spread, and particularly bone involvement, in patients with prostate cancer, to reinforce or substitute information provided by bone scan. Each radiopharmaceutical has a specific mechanism of uptake; therefore, diagnostic performances may differ from one radiopharmaceutical to another on the same lesions, as demonstrated in the literature, with variable sensitivity, specificity, and overall accuracy values in the same patients. Whether bone scintigraphy can be substituted by these new methods is a matter of debate. However, greater radiobiological burden, higher costs, and the necessity of an in-site cyclotron limit the use of these positron emission tomography methods as first-line investigations in patients with prostate cancer: bone scintigraphy remains the mainstay for the detection of bone metastases in current clinical practice. PMID:23861598

  6. The relationship between skeletal-related events and bone scan index for the treatment of bone metastasis with breast cancer patients.

    PubMed

    Iwase, Toshiaki; Yamamoto, Naohito; Ichihara, Hironori; Togawa, Takashi; Nagashima, Takeshi; Miyazaki, Masaru

    2014-12-01

    The aim of the present study was to investigate the relationships between the automated bone scan index (aBSI) and skeletal-related events (SRE) in breast cancer patients with bone metastasis. A computer-aided software (BONENAVI™) that was developed using an Artificial Neural Network (Artificial Neural Network) was used for the present analysis. Forty-five patients diagnosed with bone metastasis due to breast cancer from April 2005 through March 2013 were retrospectively analyzed. Before and after the time of initial treatment, aBSI, Artificial Neural Network score, and hotspot number were calculated, and the relationships between these scores and SRE were analyzed. Twenty cases showed decreased (improved) aBSI values after initial treatment (Group A), and 25 cases showed unchanged/increased (worsened) aBSI values (Group B). Chi-square analysis revealed a significant difference in incident numbers of SRE between the two groups--one case in Group A and 12 in Group B (P<0.001). Event-free survival was significantly shorter in Group B (hazard ratio: 8.31, 95% CI: 1.33-12.14, log-rank test; P<0.05). The groups were also divided by the results of 2 radiologists' visual scan interpretations, and no significant differences were shown in the number of SRE (P=0.82, P=0.10). When correlation analyses were performed between aBSI and bone metabolic or tumor markers, alkaline phosphatase was significantly correlated with aBSI at the time of initial treatment (R=0.69, P<0.05). In conclusion, aBSI is proposed as a useful and objective imaging biomarker in the detection of breast-cancer patients with bone metastasis at high risk of SRE.

  7. Association of non-traumatic complex regional pain syndrome with adenocarcinoma lung on 99mTc-MDP bone scan

    PubMed Central

    Damle, Nishikant A; Tripathi, Madhavi; Singhal, Abhinav; Bal, Chandrasekhar; Kumar, Praveen; Kandasamy, Devasenathipathi; Jana, Manisha

    2012-01-01

    Complex regional pain syndrome (CRPS) is usually associated with trauma. Rarely, it may be seen in association with malignancies. We present here the bone scan and X-ray findings in the case of a 56-year-male-patient with adenocarcinoma lung who also had non-traumatic CRPS without involvement of the stellate ganglion. The case highlights the fact that spontaneous development of reflex sympathetic dystrophy may be associated with a neoplastic etiology. PMID:24019656

  8. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    SciTech Connect

    Alexander, J.E.; Seibert, J.J.; Aronson, J.; Williamson, S.L.; Glasier, C.M.; Rodgers, A.B.; Corbitt, S.L.

    1988-04-01

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck.

  9. Template-based automatic extraction of the joint space of foot bones from CT scan

    NASA Astrophysics Data System (ADS)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  10. Comparative study on measured variables and sensitivity to bone microstructural changes induced by weightlessness between in vivo and ex vivo micro-CT scans.

    PubMed

    Sun, Lian Wen; Wang, Chao; Pu, Fang; Li, De Yu; Niu, Hai Jun; Fan, Yu Bo

    2011-01-01

    Depending on the experimental design, micro-CT can be used to examine bones either in vivo or ex vivo (excised fresh or formalin-fixed). In this study we investigated if differences exist in the variables measured by micro-CT between in vivo and ex vivo scans and which kind of scan is more sensitive to the changes of bone microstructure induced by simulated weightlessness. Rat tail suspension was used to simulate the weightless condition. The same bone from either normal or tail-suspended rats was scanned by micro-CT both in vivo and ex vivo (fresh and fixed by formalin). Then, bone mineral density (BMD) and microstructural characteristics were analyzed. The results showed that no significant differences existed in the microstructural parameters of trabecular bone among in vivo, fresh, and formalin-fixed bone scans from both femurs and tibias, although BMD exhibited differences. On the other hand, most parameters of the tail-suspended rats measured by micro-CT deteriorated compared with controls. Ex vivo scanning appeared to be more sensitive to bone microstructural changes induced by tail suspension than in vivo scanning. In general, the results indicate that values obtained in vivo and ex vivo (fresh and fixed) are comparable, thus allowing for meaningful comparison of experimental results from different studies irrespective of the type of scans. In addition, this study suggests that it is better to use ex vivo scanning when evaluating bone microstructure under weightlessness. However, researchers can select any type of scan depending upon the objective and the demands of the experiment.

  11. Colon visualization on (99m)Tc-HDP whole-body bone scan due to sigmoid colon cancer-related enterovesical fistula.

    PubMed

    Kim, Sung Hoon; Song, Bong-Il; Won, Kyoung Sook

    2015-01-01

    An abnormally increased uptake of the bone-seeking agent is rarely observed in structures other than the bone and urinary track on bone scintigraphy. The general etiologies of soft tissue uptake can be explained by heterotopic ossification or dystrophic and metastatic calcification. We report a case of serendipitous visualization of the entire colon on bone scintigraphy. Diffuse colonic uptake was detected on the whole-body bone scan in a patient with biopsy-proven sigmoid colon cancer. Additional imaging studies clearly showed direct bladder invasion of the sigmoid colon cancer. Imaging findings with a brief review of the literature are presented in this article.

  12. Which metabolic imaging, besides bone scan with 99mTc-phosphonates, for detecting and evaluating bone metastases in prostatic cancer patients? An open discussion.

    PubMed

    Bombardieri, E; Setti, L; Kirienko, M; Antunovic, L; Guglielmo, P; Ciocia, G

    2015-12-01

    Prostate cancer bone metastases occur frequently in advanced cancer and this is matter of particular attention, due to the great impact on patient's management and considering that a lot of new emerging therapeutic options have been recently introduced. Imaging bone metastases is essential to localize lesions, to establish their size and number, to study characteristics and changes during therapy. Besides radiological imaging, nuclear medicine modalities can image their features and offer additional information about their metabolic behaviour. They can be classified according to physical characteristics, type of detection, mechanism of uptake, availability for daily use. The physiopathology of metastases formation and the mechanisms of tracer uptake are essential to understand the interpretation of nuclear medicine images. Therefore, radiopharmaceuticals for bone metastases can be classified in agents targeting bone (99mTc-phosphonates, 18F-fluoride) and those targeting prostatic cancer cells (18F-fluoromethylcholine, 11C-choline, 18F-fluorodeoxyglucose). The modalities using the first group of tracers are planar bone scan, SPECT or SPECT/CT with 99mTc-diphosphonates, and 18F-fluoride PET/CT, while the modalities using the second group include 18F/11C-choline derivatives PET/CT, 18F-FDG PET/CT and PET/CT scans with several other radiopharmaceuticals described in the literature, such as 18F/11C-acetate derivatives, 18F-fluoro-5α-dihydrotestosterone (FDHT), 18F-anti-1-amino-3-fluorocyclobutane-1-carboxylic acid (FACBC), 18F-2'-fluoro-5-methyl-1-β-D-arabinofuranosyluracil (FMAU) and 68Ga-labeled-prostate specific membrane antigen (PMSA) PET/TC. However, since data on clinical validation for these last novel modalities are not conclusive and/or are not still sufficient in number, at present they can be still considered as promising tools under evaluation. The present paper considers the nuclear modalities today available for the clinical routine. This overview wants

  13. Gallium scan

    MedlinePlus

    Liver gallium scan; Bony gallium scan ... You will get a radioactive material called gallium injected into your vein. The gallium travels through the bloodstream and collects in the bones and certain organs. Your health care provider will ...

  14. CT scans and 3D reconstructions of Florida manatee (Trichechus manatus latirostris) heads and ear bones.

    PubMed

    Chapla, Marie E; Nowacek, Douglas P; Rommel, Sentiel A; Sadler, Valerie M

    2007-06-01

    The auditory anatomy of the Florida manatee (Trichechus manatus latirostris) was investigated using computerized tomography (CT), three-dimensional reconstructions, and traditional dissection of heads removed during necropsy. The densities (kg/m3) of the soft tissues of the head were measured directly using the displacement method and those of the soft tissues and bone were calculated from CT measurements (Hounsfield units). The manatee's fatty tissue was significantly less dense than the other soft tissues within the head (p<0.05). The squamosal bone was significantly less dense than the other bones of the head (p<0.05). Measurements of the ear bones (tympanic, periotic, malleus, incus, and stapes) collected during dissection revealed that the ossicular chain was overly massive for the mass of the tympanoperiotic complex.

  15. CT scans and 3D reconstructions of Florida manatee (Trichechus manatus latirostris) heads and ear bones.

    PubMed

    Chapla, Marie E; Nowacek, Douglas P; Rommel, Sentiel A; Sadler, Valerie M

    2007-06-01

    The auditory anatomy of the Florida manatee (Trichechus manatus latirostris) was investigated using computerized tomography (CT), three-dimensional reconstructions, and traditional dissection of heads removed during necropsy. The densities (kg/m3) of the soft tissues of the head were measured directly using the displacement method and those of the soft tissues and bone were calculated from CT measurements (Hounsfield units). The manatee's fatty tissue was significantly less dense than the other soft tissues within the head (p<0.05). The squamosal bone was significantly less dense than the other bones of the head (p<0.05). Measurements of the ear bones (tympanic, periotic, malleus, incus, and stapes) collected during dissection revealed that the ossicular chain was overly massive for the mass of the tympanoperiotic complex. PMID:17420106

  16. Non-invasive assessment of bone quantity and quality in human trabeculae using scanning ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Xia, Yi

    Fractures and associated bone fragility induced by osteoporosis and osteopenia are widespread health threat to current society. Early detection of fracture risk associated with bone quantity and quality is important for both the prevention and treatment of osteoporosis and consequent complications. Quantitative ultrasound (QUS) is an engineering technology for monitoring bone quantity and quality of humans on earth and astronauts subjected to long duration microgravity. Factors currently limiting the acceptance of QUS technology involve precision, accuracy, single index and standardization. The objective of this study was to improve the accuracy and precision of an image-based QUS technique for non-invasive evaluation of trabecular bone quantity and quality by developing new techniques and understanding ultrasound/tissue interaction. Several new techniques have been developed in this dissertation study, including the automatic identification of irregular region of interest (iROI) in bone, surface topology mapping (STM) and mean scattering spacing (MSS) estimation for evaluating trabecular bone structure. In vitro results have shown that (1) the inter- and intra-observer errors in QUS measurement were reduced two to five fold by iROI compared to previous results; (2) the accuracy of QUS parameter, e.g., ultrasound velocity (UV) through bone, was improved 16% by STM; and (3) the averaged trabecular spacing can be estimated by MSS technique (r2=0.72, p<0.01). The measurement errors of BUA and UV introduced by the soft tissue and cortical shells in vivo can be quantified by developed foot model and simplified cortical-trabecular-cortical sandwich model, which were verified by the experimental results. The mechanisms of the errors induced by the cortical and soft tissues were revealed by the model. With developed new techniques and understanding of sound-tissue interaction, in vivo clinical trail and bed rest study were preformed to evaluate the performance of QUS in

  17. Role of 99mTc-MDP bone scan in the diagnosis of Erdheim–Chester disease

    PubMed Central

    Mukherjee, Anirban; Damle, Nishikant; Bal, Chandrasekhar; Arora, Arundeep; Singhal, Abhinav; Tripathi, Madhavi; Peepre, Karan

    2014-01-01

    Erdheim–Chester disease (ECD) is a rare systemic non-Langerhans cell histiocytosis. It is a progressive disease of unknown etiology. The 99mtechnetium-methylene diphosphonate (99mTc-MDP) bone scan is useful in finding the sites of involvement in the skeleton and is helpful in excluding other causes of bony pain. Also a scintigraphic pattern consistent with ECD should alert the physician to evaluate the patient for visceral sites of involvement using fludeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), as this is known to be fatal at times. PMID:25210284

  18. Semiautomated three-dimensional segmentation software to quantify carpal bone volume changes on wrist CT scans for arthritis assessment.

    PubMed

    Duryea, J; Magalnick, M; Alli, S; Yao, L; Wilson, M; Goldbach-Mansky, R

    2008-06-01

    Rapid progression of joint destruction is an indication of poor prognosis in patients with rheumatoid arthritis. Computed tomography (CT) has the potential to serve as a gold standard for joint imaging since it provides high resolution three-dimensional (3D) images of bone structure. The authors have developed a method to quantify erosion volume changes on wrist CT scans. In this article they present a description and validation of the methodology using multiple scans of a hand phantom and five human subjects. An anthropomorphic hand phantom was imaged with a clinical CT scanner at three different orientations separated by a 30-deg angle. A reader used the semiautomated software tool to segment the individual carpal bones of each CT scan. Reproducibility was measured as the root-mean-square standard deviation (RMMSD) and coefficient of variation (CoV) between multiple measurements of the carpal volumes. Longitudinal erosion progression was studied by inserting simulated erosions in a paired second scan. The change in simulated erosion size was calculated by performing 3D image registration and measuring the volume difference between scans in a region adjacent to the simulated erosion. The RMSSD for the total carpal volumes was 21.0 mm3 (CoV = 1.3%) for the phantom, and 44.1 mm3 (CoV = 3.0%) for the in vivo subjects. Using 3D registration and local volume difference calculations, the RMMSD was 1.0-3.0 mm3 The reader time was approximately 5 min per carpal bone. There was excellent agreement between the measured and simulated erosion volumes. The effect of a poorly measured volume for a single erosion is mitigated by the large number of subjects that would comprise a clinical study and that there will be many erosions measured per patient. CT promises to be a quantifiable tool to measure erosion volumes and may serve as a gold standard that can be used in the validation of other modalities such as magnetic resonance imaging.

  19. Altered biodistribution and incidental findings on gallium and labeled leukocyte/bone marrow scans.

    PubMed

    Love, Charito; Palestro, Christopher J

    2010-07-01

    Gallium-67 citrate and labeled leukocyte imaging are established procedures for diagnosing inflammation and infection. Knowledge of the normal biodistribution of these tracers, variations, and unusual disease presentations improves the accuracy of their interpretation. During the first 24 hours after injection, the principal excretory pathway of gallium is renal; subsequently, excretion is primarily colonic. By 72 hours, approximately 75% remains in the body, equally distributed among soft tissues, liver, and bone/bone marrow. This normal distribution is subject to considerable variation. Nasopharyngeal and lacrimal gland uptake can be prominent. Breast uptake, generally faint and symmetric, is intense in hyperprolactinemic states such as pregnancy. Colonic uptake is very variable. Normally healing surgical incisions concentrate gallium for variable amounts of time. In patients receiving multiple transfusions renal, bladder, and bone activity are increased; liver and colon uptake are decreased. The contrast agent gadolinium exerts similar effects. At 24 hours after injection, the normal biodistribution of indium labeled leukocytes is limited to liver, spleen, and bone marrow. The normal biodistribution of technetium-labeled leukocytes includes, in addition to the reticuloendothelial system, colon, urinary tract, and occasionally gall bladder. Images obtained shortly after injection of labeled leukocytes show intense pulmonary activity, which decreases over time. Except in cystic fibrosis, segmental or lobar pulmonary activity indicates bacterial pneumonia. Diffuse pulmonary uptake is associated with various conditions but rarely with bacterial pneumonia. Labeled leukocytes do not accumulate in surgical wounds that heal by primary intention. They do accumulate in wounds healing by secondary intention, such as ostomies and skin grafts. Because labeled leukocytes accumulate in the bone marrow, complementary bone marrow imaging helps differentiate marrow activity from

  20. Genome-Wide Linkage Scan for Quantitative Trait Loci Underlying Normal Variation in Heel Bone Ultrasound Measures

    PubMed Central

    Lee, M.; Choh, A.C.; Williams, K.D.; Schroeder, V.; Dyer, T.D.; Blangero, J.; Cole, S.A.; Chumlea, WM.C.; Duren, D.L.; Sherwood, R.J.; Siervogel, R.M.; Towne, B.; Czerwinski, S.A.

    2012-01-01

    Quantitative ultrasound (QUS) traits are correlated with bone mineral density (BMD), but predict risk for future fracture independent of BMD. Only a few studies, however, have sought to identify specific genes influencing calcaneal QUS measures. The aim of this study was to conduct a genome-wide linkage scan to identify quantitative trait loci (QTL) influencing normal variation in QUS traits. QUS measures were collected from a total of 719 individuals (336 males and 383 females) from the Fels Longitudinal Study who have been genotyped and have at least one set of QUS measurements. Participants ranged in age from 18.0 to 96.6 years and were distributed across 110 nuclear and extended families. Using the Sahara ® bone sonometer, broadband ultrasound attenuation (BUA), speed of sound (SOS) and stiffness index (QUI) were collected from the right heel. Variance components based linkage analysis was performed on the three traits using 400 polymorphic short tandem repeat (STR) markers spaced approximately 10 cM apart across the autosomes to identify QTL influencing the QUS traits. Age, sex, and other significant covariates were simultaneously adjusted. Heritability estimates (h2) for the QUS traits ranged from 0.42 to 0.57. Significant evidence for a QTL influencing BUA was found on chromosome 11p15 near marker D11S902 (LOD = 3.11). Our results provide additional evidence for a QTL on chromosome 11p that harbors a potential candidate gene(s) related to BUA and bone metabolism. PMID:22237995

  1. Assessment of Microelastic Properties of Bone Using Scanning Acoustic Microscopy: A Face-to-Face Comparison with Nanoindentation

    NASA Astrophysics Data System (ADS)

    Rupin, Fabienne; Saïed, Amena; Dalmas, Davy; Peyrin, Françoise; Haupert, Sylvain; Raum, Kay; Barthel, Etienne; Boivin, Georges; Laugier, Pascal

    2009-07-01

    The current work aimed at comparing, on site-matched cortical bone tissue, the micron-level elastic modulus Ea derived from 200 MHz-scanning acoustic microscopy (SAM) acoustic impedance (Z) combined with bone mineral density (assessed by synchrotron radiation microcomputed tomography, SR-µCT) to nanoindentation modulus En. A good correlation was observed between En and Z (R2=0.67, p<0.0001, root mean square error RMSE=1.9 GPa). The acoustical elastic modulus Ea derived from Z showed higher values of E compared to nanoindentation moduli. We assumed that the discrepancy between Ea and En values may likely be due to the fixed assumed value of Poisson's ratio while values comprised between 0.15 and 0.45 have been reported in the literature. Despite these differences, a highly significant correlation between Ea and En was found (R2=0.66, p<0.001, RMSE=1.8 GPa) suggesting that SAM can reliably be used as a modality to quantitatively map the local variations of tissue-level bone elasticity.

  2. Astronaut Bone Medical Standards Derived from Finite Element (FE) Models of QCT Scans from Population Studies

    NASA Technical Reports Server (NTRS)

    Sibonga, J. D.; Feiveson, A. H.

    2014-01-01

    This work was accomplished in support of the Finite Element [FE] Strength Task Group, NASA Johnson Space Center [JSC], Houston, TX. This group was charged with the task of developing rules for using finite-element [FE] bone-strength measures to construct operating bands for bone health that are relevant to astronauts following exposure to spaceflight. FE modeling is a computational tool used by engineers to estimate the failure loads of complex structures. Recently, some engineers have used this tool to characterize the failure loads of the hip in population studies that also monitored fracture outcomes. A Directed Research Task was authorized in July, 2012 to investigate FE data from these population studies to derive these proposed standards of bone health as a function of age and gender. The proposed standards make use of an FE-based index that integrates multiple contributors to bone strength, an expanded evaluation that is critical after an astronaut is exposed to spaceflight. The current index of bone health used by NASA is the measurement of areal BMD. There was a concern voiced by a research and clinical advisory panel that the sole use of areal BMD would be insufficient to fully evaluate the effects of spaceflight on the hip. Hence, NASA may not have a full understanding of fracture risk, both during and after a mission, and may be poorly estimating in-flight countermeasure efficacy. The FE Strength Task Group - composed of principal investigators of the aforementioned population studies and of FE modelers -donated some of its population QCT data to estimate of hip bone strength by FE modeling for this specific purpose. Consequently, Human Health Countermeasures [HHC] has compiled a dataset of FE hip strengths, generated by a single FE modeling approach, from human subjects (approx.1060) with ages covering the age range of the astronauts. The dataset has been analyzed to generate a set of FE strength cutoffs for the following scenarios: a) Qualify an

  3. Increasing body fat mass reverses bone loss in osteopenia as detected by dual-energy X-ray absorptiometry scans

    PubMed Central

    Hedges, William P.; Bukhari, Marwan

    2016-01-01

    Objective Low body mass index (BMI) is a known risk factor for osteoporosis and is part of the FRAX™ 10-year fracture risk stratification tool for predicting fragility fractures. Little is known regarding the effects of changing body composition on bone mineral density (BMD). However, increasing fat mass (FM) improves BMD in young women with anorexia nervosa. This study aimed to assess whether changes in FM over time affected BMD in the general population. Material and Methods Data was collected from patients who underwent dual-energy X-ray absorptiometry (DEXA) assessment between 2004 and 2011. Patients were included if they had multiple scans, including FM measurements. Our scanners limited these to scans of the lumbar spine. Linear regression analysis was performed to identify the relationship between changes in FM and BMD. Backwards stepwise linear regression analysis was performed to identify confounding factors, including sex, risk factors, previous fractures, and baseline BMI. Results In this study, 23,239 patients were included, of which 702 met the inclusion criteria. There were 609 (86%) females and 93 (13%) males with a mean age of 64.5 (SD 11.2) years at first scan. We identified a strong positive correlation between increasing FM and BMD between scans (coefficient 28.4; p<0.01; 95% CI, 26.6–30.1). Previous pelvic and femur fractures and a history of inflammatory diseases were also associated with increasing FM (p<0.05). This relationship was true regardless of patients BMI at their first scan. Conclusion These findings suggest that patients at high risk of fragility fractures should be encouraged to increase their FM as long as they are at a low risk for disease states related to high FM. PMID:27708960

  4. Now & Then: From Cashier to Scan Coordinator; From Stones to Bones to PC Clones.

    ERIC Educational Resources Information Center

    Barnes, Sue; Michalowicz, Karen Dee

    1994-01-01

    Discusses the changes in the scanning of food and the current use of computer technology and UPC bar codes in a grocery store and traces the history of calculating tools from the use of fingers, abacus, slide rule, calculators, and computers. Includes reproducible student activity sheets. (MKR)

  5. Morphometric analysis of osteonal architecture in bones from healthy young human male subjects using scanning electron microscopy.

    PubMed

    Pazzaglia, Ugo E; Congiu, Terenzio; Pienazza, Alberto; Zakaria, Mohammed; Gnecchi, Michele; Dell'orbo, Carlo

    2013-09-01

    The shape and structure of bones is a topic that has been studied for a long time by morphologists and biologists with the goal of explaining the laws governing their development, aging and pathology. The osteonal architecture of tibial and femoral mid-diaphyses was examined morphometrically with scanning electron microscopy in four healthy young male subjects. In transverse sections of the mid-diaphysis, the total area of the anterior, posterior, lateral and medial cortex sectors was measured and analysed for osteonal parameters including osteon number and density, osteon total and bone area and vascular space area. Osteons were grouped into four classes including cutting heads (A), transversely cut osteons (B), longitudinally cut osteons (C) and sealed osteons (D). The morphometric parameters were compared between the inner (endosteal) and outer (periosteal) half of the cortex. Of 5927 examined osteons, 24.4% cutting heads, 71.1% transversely cut osteons, 2.3% longitudinally cut osteons and 2.2% sealed osteons were found. The interosteonic bone (measured as the area in a lamellar system that has lost contact with its own central canal) corresponded to 51.2% of the endosteal and 52.4% of the periosteal half-cortex. The mean number of class A cutting heads and class B osteons was significantly higher in the periosteal than in the endosteal half-cortex (P < 0.001 and P < 0.05, respectively), whereas there was no significant difference in density. The mean osteon total area, osteon bone area and vascular space area of both classes A and B were significantly higher (P < 0.001 for all three parameters) in the endosteal than in the periosteal half-cortex. The significant differences between the two layers of the cortex suggest that the osteoclast activity is distributed throughout the whole cortical thickness, with more numerous excavations in the external layer, but larger resorption lacunae closer to the marrow canal. A randomly selected population of 109 intact

  6. Frostbite and bone scanning: the use of 99mTc-labeled phosphates in demarcating the line of viability in frostbite victims

    SciTech Connect

    Ikawa, G.; dos Santos, P.A.; Yamaguchi, K.T.; Stroh-Recor, C.; Ibello, R.

    1986-09-01

    Early diagnosis of the extent of bone and soft tissue damage is a very important step in treating a frostbite victim. The diagnostic use of Tc-99m-phosphates in assessing the viability of soft tissue and bone in frostbite was evaluated in the early post-thaw period. Four patients were treated with a combination of warm baths, rehydration, vasodilators, epidural block, fasciotomy, and debridement. Six scans were done to stage involvement. In three of the four cases, final involvement could be determined as early as the third day. When a specific level of soft tissue or bone uptake was determined, future scanning showed either improvement, or no change in three of the four patients. In our experience, Tc-99m-phosphate scans represent an improvement over other diagnostic tests for viability of tissues.

  7. A Comparative Study of Bone Scan Findings and Serum Levels of Tumor Marker CA15-3 in Patients with Breast Carcinoma.

    PubMed

    Ghadge, Meera S; Naik, Purva P; Tiwari, Bijaynath P; Hegde, Ruprekha M; Matale, Tanaji J

    2012-01-01

    Breast cancer is one of the most frequent malignancies in the world. Available staging procedures to detect breast cancer are bone scan, chest X-ray, liver ultrasonography, computerized tomography, estimation of tumor markers like carbohydrate antigen (CA15-3) and carcino embryonic antigen. These procedures are expensive and may not be required in all cases. Out of 70 patients studied, 55 had normal CA15-3 and 15 had elevated levels of Ca15-3. Eight (14.5%) of the 55 patients with normal CA15-3 had abnormal bone scan. Fifteen patients had CA15-3 levels above the normal range and among these 9 (60%) had abnormal bone scan. While prime facie it would appear that a high level of CA15-3 correlate with abnormal bone scan, it is also true that the numbers are small at present and conclusions about the validity of CA15-3 as marker of bone metastasis may be premature.

  8. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype

    PubMed Central

    Al Kaissi, Ali; Chehida, Farid Ben; Ganger, Rudolf; Grill, Franz

    2014-01-01

    We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT) scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (consanguineous marriage) strongly suggests autosomal recessive pattern of inheritance. To our knowledge, this is the first report of neonatal death dwarfism of Grebe syndrome analyzed by CT scan-based phenotype. PMID:25337439

  9. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    SciTech Connect

    Hunter, J.C.; Hattner, R.S.; Murray, W.R.; Genant, H.K.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery and seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.

  10. Scanning electron microscope analysis of gunshot defects to bone: an underutilized source of information on ballistic trauma.

    PubMed

    Rickman, John M; Smith, Martin J

    2014-11-01

    Recent years have seen increasing involvement by forensic anthropologists in the interpretation of skeletal trauma. With regard to ballistic injuries, there is now a large literature detailing gross features of such trauma; however, less attention has been given to microscopic characteristics. This article presents analysis of experimentally induced gunshot trauma in animal bone (Bos taurus scapulae) using full metal jacket (FMJ), soft point (SP), and captive bolt projectiles. The results were examined using scanning electron microscopy (SEM). Additional analysis was conducted on a purported parietal gunshot lesion in a human cranial specimen. A range of features was observed in these samples suggesting that fibrolamellar bone response to projectile impact is analogous to that observed in synthetic composite laminates. The results indicate that direction of bullet travel can be discerned microscopically even when it is ambiguous on gross examination. It was also possible to distinguish SP from FMJ lesions. SEM analysis is therefore recommended as a previously underexploited tool in the analysis of ballistic trauma.

  11. Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model.

    PubMed

    Han, Songfeng; Johansson, Johannes; Mireles, Miguel; Proctor, Ashley R; Hoffman, Michael D; Vella, Joseph B; Benoit, Danielle S W; Durduran, Turgut; Choe, Regine

    2015-07-01

    A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing.

  12. Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model.

    PubMed

    Han, Songfeng; Johansson, Johannes; Mireles, Miguel; Proctor, Ashley R; Hoffman, Michael D; Vella, Joseph B; Benoit, Danielle S W; Durduran, Turgut; Choe, Regine

    2015-07-01

    A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing. PMID:26203392

  13. Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model

    PubMed Central

    Han, Songfeng; Johansson, Johannes; Mireles, Miguel; Proctor, Ashley R.; Hoffman, Michael D.; Vella, Joseph B.; Benoit, Danielle S. W.; Durduran, Turgut; Choe, Regine

    2015-01-01

    A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing. PMID:26203392

  14. Bone

    NASA Astrophysics Data System (ADS)

    Helmberger, Thomas K.; Hoffmann, Ralf-Thorsten

    The typical clinical signs in bone tumours are pain, destruction and destabilization, immobilization, neurologic deficits, and finally functional impairment. Primary malignant bone tumours are a rare entity, accounting for about 0.2% of all malignancies. Also benign primary bone tumours are in total rare and mostly asymptomatic. The most common symptomatic benign bone tumour is osteoid osteoma with an incidence of 1:2000.

  15. Bone Densitometry (Bone Density Scan)

    MedlinePlus

    ... a physician specifically trained to supervise and interpret radiology examinations, will analyze the images and send a ... the best images for evaluation. National and international radiology protection organizations continually review and update the technique ...

  16. Scanning Electron Microscopy Reveals Two Distinct Classes of Erythroblastic Island Isolated from Adult Mammalian Bone Marrow.

    PubMed

    Yeo, Jia Hao; McAllan, Bronwyn M; Fraser, Stuart T

    2016-04-01

    Erythroblastic islands are multicellular clusters in which a central macrophage supports the development and maturation of red blood cell (erythroid) progenitors. These clusters play crucial roles in the pathogenesis observed in animal models of hematological disorders. The precise structure and function of erythroblastic islands is poorly understood. Here, we have combined scanning electron microscopy and immuno-gold labeling of surface proteins to develop a better understanding of the ultrastructure of these multicellular clusters. The erythroid-specific surface antigen Ter-119 and the transferrin receptor CD71 exhibited distinct patterns of protein sorting during erythroid cell maturation as detected by immuno-gold labeling. During electron microscopy analysis we observed two distinct classes of erythroblastic islands. The islands varied in size and morphology, and the number and type of erythroid cells interacting with the central macrophage. Assessment of femoral marrow isolated from a cavid rodent species (guinea pig, Cavis porcellus) and a marsupial carnivore species (fat-tailed dunnarts, Sminthopsis crassicaudata) showed that while the morphology of the central macrophage varied, two different types of erythroblastic islands were consistently identifiable. Our findings suggest that these two classes of erythroblastic islands are conserved in mammalian evolution and may play distinct roles in red blood cell production. PMID:26898901

  17. Assessment of trabecular bone quality in human cadaver calcaneus using scanning confocal ultrasound and dual x-ray absorptiometry (DEXA) measurements

    NASA Astrophysics Data System (ADS)

    Qin, Yixian; Xia, Yi; Lin, Wei; Rubin, Clinton; Gruber, Barry

    2004-10-01

    Microgravity and aging induced bone loss is a critical skeleton complication, occurring particularly in the weight-supporting skeleton, which leads to osteoporosis and fracture. Advents in quantitative ultrasound (QUS) provide a unique method for evaluating bone strength and density. Using a newly developed scanning confocal acoustic diagnostic (SCAD) system, QUS assessment for bone quality in the real body region was evaluated. A total of 19 human cadaver calcanei, age 66 to 97 years old, were tested by both SCAD and nonscan mode. The scanning region covered an approximate 40×40 mm2 with 0.5 mm resolution. Broadband ultrasound attenuation (BUA, dB/MHz), energy attenuation (ATT, dB), and ultrasound velocity (UV, m/s) were measured. The QUS properties were then correlated to the bone mineral density (BMD) measured by DEXA. Correlations between BMD and QUS parameters were significantly improved by using SCAD as compared to nonscan mode, yielding correlations between BMD and SCAD QUS parameters as R=0.82 (BUA), and R=0.86 (est. BMD). It is suggested that SCAD is feasible for in vivo bone quality mapping. It can be potentially used for monitoring instant changes of bone strength and density. [Work supported by the National Space Biomedical Research Institute (TD00207), and New York Center for Biotechnology.

  18. Random field assessment of inhomogeneous bone mineral density from DXA scans can enhance the differentiation between postmenopausal women with and without hip fractures

    PubMed Central

    Dong, Xuanliang Neil; Pinninti, Rajeshwar; Lowe, Timothy; Cussen, Patricia; Ballard, Joyce E.; Paolo, David Di; Shirvaikar, Mukul

    2015-01-01

    Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogeneity, the BMD map in the hip region is considered as a random field and stochastic predictors can be calculated by fitting a theoretical model onto the experimental variogram of the BMD map. The objective of this study was to compare the ability of bone mineral density and stochastic assessment of inhomogeneous distribution of bone mineral density in predicting hip fractures for postmenopausal women. DXA scans in the hip region were obtained from postmenopausal women with hip fractures (N=47, Age: 71.3±11.4 years) and without hip fractures (N=45, Age: 66.7±11.4 years). Comparison of BMD measurements and stochastic predictors in assessing bone fragility was based on the area under the receiver operating characteristic curves (AUC) from logistic regression analyses. Although stochastic predictors offered higher accuracy (AUC=0.675) in predicting the risk of hip fractures than BMD measurements (AUC=0.625), such difference was not statistically significant (p=0.548). Nevertheless, the combination of stochastic predictors and BMD measurements had significantly (p=0.039) higher prediction accuracy (AUC=0.748) than BMD measurements alone. This study demonstrates that stochastic assessment of bone mineral distribution from DXA scans can serve as a valuable tool in enhancing the prediction of hip fractures for postmenopausal women in addition to BMD measurements. PMID:25683520

  19. Measuring muscle and bone in individuals with neurologic impairment; lessons learned about participant selection and pQCT scan acquisition and analysis.

    PubMed

    Giangregorio, L M; Gibbs, J C; Craven, B C

    2016-08-01

    Peripheral quantitative computed tomography (pQCT) can be used to examine bone strength outcomes and muscle size and fatty infiltration. Our research team and others have used it to examine bone loss after spinal cord injury (SCI). However, the high prevalence of restricted lower extremity range of motion, spasticity, edema, excessive muscle atrophy, or severe osteoporosis necessitates changes to standard protocols for screening, positioning during scan acquisition, and analysis methods. This manuscript outlines the challenges that we experienced using pQCT in individuals with SCI, and provides solutions, ones that may also be applicable when using pQCT in individuals with other chronic conditions or in older adults. Suggestions for participant screening, positioning individuals for scanning while in a wheelchair, scan site selection, need for attendant assistance, and considerations in the presence of secondary complications, such as contracture, spasticity, and paralysis, are presented. In the presence of very low bone mineral density or severe muscle atrophy, the default analysis modes provided by the manufacturer may not provide valid estimates of bone or muscle indices; we propose alternates. We have used watershed segmentation methods to determine muscle size and density based on lower precision error compared to threshold-based edge-detection segmentation, particularly for adults with SCI, where more fatty infiltration was present. By presenting our "lessons learned," we hope to reduce the learning curve for researchers using pQCT in the future. PMID:27026329

  20. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    SciTech Connect

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-07-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit.

  1. Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences

    PubMed Central

    Lundblad, Henrik; Maguire, Gerald Q.; Karlsson-Thur, Charlotte; Jonsson, Cathrine; Noz, Marilyn E.; Zeleznik, Michael P.; Jacobsson, Hans; Weidenhielm, Lars

    2015-01-01

    Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na18F− PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV) derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs) were drawn to include broken bone, other (normal) bone, and muscle. The SUVm(t) (m = max, mean) and a series of slopes were computed as (SUVm(ti) − SUVm(tj))/(ti − tj), for pairs of time values ti and tj. A Patlak-like analysis was performed for the same time values by computing ((VOIp(ti)/VOIe(ti))−(VOIp(tj)/VOIe(tj)))/(ti − tj), where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUVm slopes showed good agreement by both linear regression and correlation coefficient analysis (r = 84%, rs = 78%-SUVmax, r = 92%, and rs = 91%-SUVmean), suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min−1 or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of −0.06 min−1 usually indicated poor remodeling progress in this cohort. PMID:26436093

  2. Bone tumor

    MedlinePlus

    ... physical exam. Tests that may be done include: Alkaline phosphatase blood level Bone biopsy Bone scan Chest x- ... may also be ordered to monitor the disease: Alkaline phosphatase isoenzyme Blood calcium level Parathyroid hormone Blood phosphorus ...

  3. Skeletal Scintigraphy (Bone Scan)

    MedlinePlus

    ... young patients, sedation is seldom necessary. Risks Allergic reactions to radiopharmaceuticals may occur but are extremely rare and are usually mild. Nevertheless, you should inform the nuclear medicine personnel of any allergies you may have ...

  4. Bone Scan "Hot Spot" at the Superior Lateral Orbital Margin Fronto-zygomatic Suture Uptake Characterized with Tc-99m MDP SPECT/CT.

    PubMed

    Thang, S P; Tan, A E H; Goh, A S W

    2011-07-01

    Findings of a solitary "hot spot" at the superior lateral orbital margin on bone scan scintigraphy is not uncommonly seen, and is often dismissed as a benign lesion. However, the exact etiology is indeterminate. We present two cases in which hybrid single photon emission computed tomography/computed tomography imaging was able to characterize and localize this uptake, demonstrating correlation to the right fronto-zygomatic suture.

  5. Recurrent surgical site infection of the spine diagnosed by dual (18)F-NaF-bone PET/CT with early-phase scan.

    PubMed

    Shim, Jai-Joon; Lee, Jeong Won; Jeon, Min Hyok; Lee, Sang Mi

    2016-09-01

    We report a case of a 31-year-old man who showed recurrently elevated level of the serum inflammatory marker C-reactive protein (CRP) after spinal operation. He underwent (18)F-flurodeoxyglucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) and dual (18)F-sodium-fluoride ((18)F-NaF) PET/CT with an additional early-phase scan to find a hidden inflammation focus. Only mildly increased (18)F-FDG was found at the surgical site of T11 spine on (18)F-FDG PET/CT. In contrast, dual (18)F-NaF bone PET/CT with early-phase scan demonstrated focal active inflammation at the surgical site of T11 spine. After a revision operation of the T11 spine, serum CRP level decreased to the normal range without any symptom or sign of inflammation. Inflammatory focus in the surgical site of the spine can be detected with using dual (18)F-NaF bone PET/CT scan with early-phase scan.

  6. Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences.

    PubMed

    Lundblad, Henrik; Maguire, Gerald Q; Karlsson-Thur, Charlotte; Jonsson, Cathrine; Noz, Marilyn E; Zeleznik, Michael P; Jacobsson, Hans; Weidenhielm, Lars

    2015-01-01

    Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na(18)F(-) PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV) derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs) were drawn to include broken bone, other (normal) bone, and muscle. The SUV m (t) (m = max, mean) and a series of slopes were computed as (SUV m (t i ) - SUV m (t j ))/(t i - t j ), for pairs of time values t i and t j . A Patlak-like analysis was performed for the same time values by computing ((VOI p (t i )/VOI e (t i ))-(VOI p (t j )/VOI e (t j )))/(t i - t j ), where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUV m slopes showed good agreement by both linear regression and correlation coefficient analysis (r = 84%, r s = 78%-SUVmax, r = 92%, and r s = 91%-SUVmean), suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min(-1) or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of -0.06 min(-1) usually indicated poor remodeling progress in this cohort. PMID:26436093

  7. Use of A-scan for penetration control during dual-frequency ultrasound thermal therapy of superficial tissues overlaying bone and lung

    NASA Astrophysics Data System (ADS)

    Moros, Eduardo G.; Straube, William L.; Fan, Xiaobing

    1999-05-01

    An ultrasonic system capable of Lateral Power Conformability, Penetration Depth Control (PDC), and the ability to deliver hyperthermia concomitantly with external beam radiation is being developed. PDC is achieved by simultaneously insonating with beams of low (1 MHz) and high (5 MHz) frequency. This paper presents a sono-thermal numerical evaluation of the impact of PDC on thermal dose in the treatment of chest wall volumes. The main goal is to assess the potential advantages of impedance-mismatched interface depth-mapping, using therapy transducers in A-scan mode, to select optimal relative output intensities of the beams as a function of bone and lung depths. Simulation results for a representative chest wall anatomy showed that there exists a strong relationship between optimal relative output intensities and bone/lung depth for maximum thermal dose and minimum muscle-bone interface temperature. Consequently, interface depth-mapping prior to a dual- frequency ultrasound hyperthermia treatment would provide patient-specific data useful for selecting PDC parameters that maximize thermal dose and minimize bone heating.

  8. EFFECTS OF CHEMICAL PROCESSING AND OXIDE ETHYLENE STERILIZATION ON CORTICAL AND CANCELLOUS RAT BONE: A LIGHT AND ELECTRON SCANNING MICROSCOPY STUDY

    PubMed Central

    Castiglia, Marcello Teixeira; da Silva, Juliano Voltarelli F.; Frezarim Thomazini, José Armendir; Volpon, José Batista

    2015-01-01

    To evaluate, under microscopic examination, the structural changes displayed by the trabecular and cortical bones after being processed chemically and sterilized by ethylene oxide. Methods: Samples of cancellous and cortical bones obtained from young female albinus rats (Wistar) were assigned to four groups according to the type of treatment: Group I- drying; Group II- drying and ethylene oxide sterilization; III- chemical treatment; IV- chemical treatment and ethylene oxide sterilization. Half of this material was analyzed under ordinary light microscope and the other half using scanning electron microscopy. Results: In all the samples, regardless the group, there was good preservation of the general morphology. For samples submitted to the chemical processing there was better preservation of the cellular content, whereas there was amalgamation of the fibres when ethylene oxide was used. Conclusion: Treatment with ethylene oxide caused amalgamation of the fibers, possibly because of heating and the chemical treatment contributed to a better cellular preservation of the osseous structure. PMID:26998450

  9. Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

    PubMed

    Sran, Meena M; Khan, Karim M; Keiver, Kathy; Chew, Jason B; McKay, Heather A; Oxland, Thomas R

    2005-12-01

    Biomechanical studies of the thoracic spine often scan cadaveric segments by dual energy X-ray absorptiometry (DXA) to obtain measures of bone mass. Only one study has reported the accuracy of lateral scans of thoracic vertebral bodies. The accuracy of DXA scans of thoracic spine segments and of anterior-posterior (AP) thoracic scans has not been investigated. We have examined the accuracy of AP and lateral thoracic DXA scans by comparison with ash weight, the gold-standard for measuring bone mineral content (BMC). We have also compared three methods of estimating volumetric bone mineral density (vBMD) with a novel standard-ash weight (g)/bone volume (cm3) as measured by computed tomography (CT). Twelve T5-T8 spine segments were scanned with DXA (AP and lateral) and CT. The T6 vertebrae were excised, the posterior elements removed and then the vertebral bodies were ashed in a muffle furnace. We proposed a new method of estimating vBMD and compared it with two previously published methods. BMC values from lateral DXA scans displayed the strongest correlation with ash weight (r=0.99) and were on average 12.8% higher (p<0.001). As expected, BMC (AP or lateral) was more strongly correlated with ash weight than areal bone mineral density (aBMD; AP: r=0.54, or lateral: r=0.71) or estimated vBMD. Estimates of vBMD with either of the three methods were strongly and similarly correlated with volumetric BMD calculated by dividing ash weight by CT-derived volume. These data suggest that readily available DXA scanning is an appropriate surrogate measure for thoracic spine bone mineral and that the lateral scan might be the scan method of choice. PMID:15616862

  10. Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

    SciTech Connect

    Tselikas, Lambros Joskin, Julien; Roquet, Florian; Farouil, Geoffroy; Dreuil, Serge; Hakimé, Antoine Teriitehau, Christophe; Auperin, Anne; Baere, Thierry de Deschamps, Frederic

    2015-02-15

    PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.

  11. Menopause and Bone Loss

    MedlinePlus

    ... You reach your highest bone mass (size and density) at about age 30. Then, sometime between age ... your bones, your doctor may do a bone density test (DEXA scan). This test gives exact measurements ...

  12. Primitive Sca-1 Positive Bone Marrow HSC in Mouse Model of Aplastic Anemia: A Comparative Study through Flowcytometric Analysis and Scanning Electron Microscopy

    PubMed Central

    Chatterjee, Sumanta; Basak, Pratima; Das, Prosun; Das, Madhurima; Pereira, Jacintha Archana; Dutta, Ranjan Kumar; Chaklader, Malay; Chaudhuri, Samaresh; Law, Sujata

    2010-01-01

    Self-renewing Hematopoietic Stem Cells (HSCs) are responsible for reconstitution of all blood cell lineages. Sca-1 is the “stem cell antigen” marker used to identify the primitive murine HSC population, the expression of which decreases upon differentiation to other mature cell types. Sca-1+ HSCs maintain the bone marrow stem cell pool throughout the life. Aplastic anemia is a disease considered to involve primary stem cell deficiency and is characterized by severe pancytopenia and a decline in healthy blood cell generation system. Studies conducted in our laboratory revealed that the primitive Sca-1+ BM-HSCs (bone marrow hematopoietic stem cell) are significantly affected in experimental Aplastic animals pretreated with chemotherapeutic drugs (Busulfan and Cyclophosphamide) and there is increased Caspase-3 activity with consecutive high Annexin-V positivity leading to premature apoptosis in the bone marrow hematopoietic stem cell population in Aplastic condition. The Sca-1bright, that is, “more primitive” BM-HSC population was more affected than the “less primitive” BM-HSC Sca-1dim  population. The decreased cell population and the receptor expression were directly associated with an empty and deranged marrow microenvironment, which is evident from scanning electron microscopy (SEM). The above experimental evidences hint toward the manipulation of receptor expression for the benefit of cytotherapy by primitive stem cell population in Aplastic anemia cases. PMID:21048851

  13. Comparison of Accuracy in Calculation of Absorbed Dose to Patients Following Bone Scan with 99mTc-Marked Diphosphonates by Two Different Background Correction Methods

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Damoori, Mehri; Tavakoli, Mohammad Bagher; Moslehi, Masoud

    2016-01-01

    To improve the accuracy of the activity quantification and the image quality in scintigraphy, scatter correction is a vital procedure. The aim of this study is to compare the accuracy in calculation of absorbed dose to patients following bone scan with 99mTc-marked diphosphonates (99mTc-MDP) by two different methods of background correction in conjugate view method. This study involved 22 patients referring to the Nuclear Medicine Center of Shahid Chamran Hospital, Isfahan, Iran. After the injection of 99mTc-MDP, whole-body images from patients were acquired at 10, 60, 90, and 180 min. Organ activities were calculated using the conjugate view method by Buijs and conventional background correction. Finally, the absorbed dose was calculated using the Medical Internal Radiation Dosimetry (MIRD) technique. The results of this study showed that the absorbed dose per unit of injected activity (rad/mCi) ± standard deviation for pelvis bone, bladder, and kidneys by Buijs method was 0.19 ± 0.05, 0.08 ± 0.01, and 0.03 ± 0.01 and by conventional method was 0.13 ± 0.04, 0.08 ± 0.01, and 0.024 ± 0.01, respectively. This showed that Buijs background correction method had a high accuracy compared to conventional method for the estimated absorbed dose of bone and kidneys whereas, for the bladder, its accuracy was low. PMID:27014610

  14. Gallium scintigraphy in bone infarction. Correlation with bone imaging

    SciTech Connect

    Armas, R.R.; Goldsmith, S.J.

    1984-01-01

    The appearance of gallium-67 images in bone infarction was studied in nine patients with sickle cell disease and correlated with the bone scan findings. Gallium uptake in acute infarction was decreased or absent with a variable bone scan uptake, and normal in healing infarcts, which showed increased uptake on bone scan. The significance of these findings is discussed.

  15. Scanning electrochemical microscopy at the surface of bone-resorbing osteoclasts: evidence for steady-state disposal and intracellular functional compartmentalization of calcium.

    PubMed

    Berger, C E; Rathod, H; Gillespie, J I; Horrocks, B R; Datta, H K

    2001-11-01

    Osteoclast resorptive activity occurs despite the presence of extremely high levels of ionized calcium ([Ca2+]) within the osteoclast hemivacuole, which is generated as a by-product of its resorptive activity. Previous in vitro observations have shown that increases in extracellular [Ca2+] ([Ca2+]e) in the surrounding medium can inhibit the osteoclast resorptive activity. Therefore, it has been suggested that the osteoclast acts as a "sensor" for [Ca2+]e, and that high [Ca2+]e leads to an increase in intracellular [Ca2+] ([Ca2+]i), thereby inhibiting osteoclasts in a negative feedback manner. In this report we have carried out an experimental and theoretical analysis of calcium disposal during osteoclast activity to evaluate how in vitro models relate to in vivo osteoclast activity, where it is possible that high [Ca2+]e may be present in the hemivacuole but not over the nonresorbing surface of the cell. Scanning electrochemical microscopy (SECM) studies of [Ca2+] and superoxide anion (O2.-) generation by bone-resorbing osteoclasts on the surface of a bovine cortical bone slice were compared with microspectofluorometric measurements of the levels of [Ca2+]i in single osteoclasts and the effect of [Ca2+]i on various aspects of osteoclast function. The generation of O2.- by the osteoclasts has been shown to be positively correlated with osteoclast resorptive function and can therefore serve as an index of acute changes in osteoclast activity. The SECM of bone-resorbing osteoclasts at the surface of a bone slice revealed a continuous steady-state release of Ca2+. Even after prolonged incubation lasting 3 h the near-surface [Ca2+]e in the solution above the cell remained <2 mM. The SECM real-time measurement data were consistent with the osteoclast acting as a conduit for continuous Ca2+ disposal from the osteoclast-bone interface. We conclude that the osteoclast distinguishes [Ca2+]e in the hemivacuole and in the extracellular fluid above the cell which we denote [Ca2

  16. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    SciTech Connect

    Caiazza, S.; Falcinelli, G.; Pintucci, S. )

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized.

  17. PROGNOSTIC VALUE OF BASELINE [18F] FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY AND 99mTc-MDP BONE SCAN IN PROGRESSING METASTATIC PROSTATE CANCER

    PubMed Central

    Meirelles, Gustavo S.P.; Schöder, Heiko; Ravizzini, Gregory C.; Gönen, Mithat; Humm, John; Morris, Michael J.; Scher, Howard I.; Larson, Steven M.

    2012-01-01

    Purpose To compare the diagnostic and prognostic value of FDG PET and bone scans (BS) in the assessment of osseous lesions in patients with progressing prostate cancer. Experimental Design In a prospective imaging trial, 43 patients underwent FDG PET and BS prior to experimental therapies. Bone scan index (BSI) and standardized uptake value (SUV) on FDG PET were recorded. Patients were followed until death (n=36) or at least 5 years (n=7). Imaging findings were correlated with survival. Results Osseous lesions were detected in 39 patients on BS and 32 on FDG PET (p=0.01). Follow-up was available for 105 FDG-positive lesions, and 84 (80%) became positive on subsequent BS. Prognosis correlated inversely with SUV (median survival 14.4 vs. 32.8 mos if SUVmax > 6.10 vs. ≤ 6.10, p=0.002) and BSI (14.7 vs. 28.2 mos if BSI >1.27 vs. < 1.27; p=0.004). Only SUV was an independent factor in multivariate analysis. In castrate resistant patients combining a nomogram for progressive prostate cancer with SUV dichotomized patients into a high vs. low risk group (median survival 14.4 vs. 34.6 mos, p=.015) more prognostic than either nomogram or SUV alone. Conclusion The current study of progressive prostate cancer confirms earlier work that BSI is a strong prognostic factor. Most FDG-only lesions at baseline become detectable on follow-up BS, suggesting their strong clinical relevance. FDG SUV is an independent prognostic factor and provides complementary prognostic information. PMID:20975102

  18. Unexplained high BMD in DXA-scanned patients is generalized throughout the skeleton and characterized by thicker cortical and trabecular bone.

    PubMed

    Lomholt, S; Amstrup, A K; Moser, E; Jakobsen, N F B; Mosekilde, L; Vestergaard, P; Rejnmark, L

    2015-04-01

    Unexplained high bone mineral density (BMD) is a rare condition and the mechanisms responsible are yet to be described in detail. The aim of the study was to identify patients with unexplained high BMD from a local DXA database and compare their radiological phenotype with an age- and a gender-matched group of population-based controls. We defined high BMD as a DXA Z-score ≥ + 2.5 at the total hip and lumbar spine. We characterized the findings as "unexplained" if no osteodegenerative changes, bone metabolic disease, or arthritis at the hip or lumbar spine was observed. All participants were investigated with high-resolution peripheral quantitative computed tomography (HR-pQCT), QCT, DXA, fasting blood samples, a 24-h urine sample, and questionnaires. The DXA database contained data on 25,118 patients. Initially, 138 (0.55%) potential participants with high BMD were identified, and during the study ten additional cases were identified from new DXA scans. Sixty-seven patients accepted to participate in the study, and among these we identified 15 women and one man with unexplained high BMD. These 15 women had higher BMD throughout the skeleton relative to controls, similar area/volume at the hip and the distal extremities, a higher number of trabeculae, which was thicker than in the controls, and a higher finite element estimated bone strength. The 15 women were heavier and had a higher fat mass then controls. We conclude that patients with unexplained high BMD have a generalized high BMD phenotype throughout their skeleton, which is characterized with a denser microarchitecture.

  19. A scanning electron microscopic study of in vitro toxicity of ethylene-oxide-sterilized bone repair materials.

    PubMed

    Zislis, T; Martin, S A; Cerbas, E; Heath, J R; Mansfield, J L; Hollinger, J O

    1989-01-01

    Polylactic acid (PLA) and polyglycolic acid (PGA) have been under investigation for use in the management of hard- and soft-tissue wounds. Current research has included the incorporation of osteo-inductive substances into a PLA-PGA copolymer alloplastic implant material for enhancement of the healing of osseous defects. Conventional methods of sterilization--such as dry heat, steam heat, or 60Co--tend either to destroy or attenuate osteo-inductive activity and alter polymer biodegradation. Ethylene oxide (EO) gas sterilization is currently being tested as an alternate method. This study examined the relationship of EO-induced cytotoxicity to the length of time of polymer aeration following EO sterilization. Three groups of copolymer implant discs were studied: (1) 50:50 PLA-PGA copolymer, (2) PLA-PGA polymer with hydroxyapatite (HA), and (3) PLA-PGA with autolyzed, antigen-extracted (AA) bone particles. Polymer discs, as well as particulate HA and AA bone controls, were sterilized with EO for 12 hours. Following periods of two weeks, one week, one day, or no subsequent vacuum aeration, samples were placed into 24-well culture plates. A suspension of human fibroblasts was added to each well. Cell growth and attachment were permitted for 24 hours. Medium was then removed, and solutions for cell fixation, buffer washing, and dehydration were added to each well. SEM examination revealed changes in cell growth with increasing periods of aeration suggestive of increasing cell vitality. Cells growing on discs having no aeration were small, round, and lobulated, whereas those of seven to 14 days' aeration were more numerous, and flattened with many microvilli, pseudopodia, and dendritic processes, features consistent with normal cell morphology. These results suggest that EO-sterilized polymer implants should be aerated for least seven to 14 days prior to surgical use. PMID:2561372

  20. A study on the evaluation of usefulness depending on the image reconstruction method in bone SPECT scan

    NASA Astrophysics Data System (ADS)

    Kim, W. H.; Kim, H. S.; Chung, W. K.; Cho, J. H.; Joo, K. J.; Dong, K. R.

    2013-05-01

    The recent advances in image-processing techniques have led to the development of many methods to reduce the scan time without degrading the image quality. In particular, tomography has improved image reconstruction methods with the concomitant improvement of high-quality images. In this study, PRECEDENCE 16 was used to reconstruct images using the filtered back projection method, which is generally used, and the Astonish method and three-dimensional ordered-subsets expectation maximization method, which are based on repetition techniques. In qualitative and quantitative analysis of the reconstructed images, a comparison was made between images with different acquisition times and between images with the same acquisition time, which aimed at determining the optimal method for reconstructing high-quality images. A blind test for qualitative analysis confirmed almost no difference in image quality depending on the image acquisition time. Furthermore, in quantitative analysis, there was no significant difference in image quality depending on the image acquisition time. On the other hand, the results of the analysis in the image reconstruction method with the same acquisition time demonstrated a significant difference. The images reconstructed by the Astonish method, which uses a repetition technique, are believed to be excellent because they have high resolution and provide clinical diagnostic information. This study confirmed that the reconstruction method with a repetition technique could be used to improve image quality and reduce the scan time, despite not being in general use until recently due to the lengthy time needed for image reconstruction and lack of storage space.

  1. The potential use of 99mTc-MDP bone scans to plan high-activity 186Re-HEDP targeted therapy of bony metastases from prostate cancer.

    PubMed

    Binnie, David; Divoli, Antigoni; McCready, V Ralph; Dearnaley, David; Flux, Glenn

    2005-04-01

    Patients with skeletal metastases from hormone-refractory prostate cancer have shown variable responses to high-activity therapy with (186)Re-HEDP and peripheral stem cell support. In this paper, we report on the use of a novel technique to compare sequential planar images acquired post-(186)Re-HEDP therapy administration with pretherapy diagnostic (99m)Tc-MDP scans, to evaluate the turnover of the radiopharmaceutical in normal and abnormal bone. It was found that the activity in normal (i.e., disease-free) segments of the spine demonstrates a faster effective decay than that of the metastases, with the latter showing only physical decay. This study showed, for the first time, a detailed correlation in the behavior of the (99m)Tc-MDP and (186)Re-HEDP images, encouraging the possibility of using the pretherapy 99mTc-MDP scan for estimations of absorbed doses to be delivered by prescribed activities of (186)Re-HEDP.

  2. Personalized estimation of dose to red bone marrow and the associated leukaemia risk attributable to pelvic kilo-voltage cone beam computed tomography scans in image-guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Zhang, Yibao; Yan, Yulong; Nath, Ravinder; Bao, Shanglian; Deng, Jun

    2012-07-01

    The aim of this study is to investigate the imaging dose to red bone marrow (RBM) and the associated leukaemia risks attributable to pelvic kilo-voltage cone beam computed tomography (kVCBCT) scans in image-guided radiation therapy (IGRT). The RBM doses of 42 patients (age 2.7-86.4 years) were calculated using Monte Carlo simulations. The trabecular spongiosa was segmented to substitute RBM rather than the whole bone. Quantitative correlations between anthropometric variables such as age, physical bone density (PBD) and RBM dose were established. Personalized leukaemia risk was evaluated using an improved Boice model which included the age-associated RBM involvement. An incremental leukaemia risk of 29%-82% (mean = 45%) was found to be associated with 40 pelvic kVCBCT scans in the subject group used in a typical external beam radiation therapy course. Higher risks were observed in children. Due to the enhanced photoelectric effect in high atomic number materials, PBD was observed to strongly affect the RBM dose. Considerable overestimations (9%-42%, mean = 28%) were observed if the whole bone doses were used as surrogates of RBM doses. The personalized estimation of RBM dose and associated leukaemia risk caused by pelvic kVCBCT scans is clinically feasible with the proposed empirical models. Higher radiogenic cancer risks are associated with repeated kVCBCT scans in IGRT of cancer patients, especially children.

  3. Analysis of the Development of the Nasal Septum and Measurement of the Harvestable Septal Cartilage in Koreans Using Three-Dimensional Facial Bone Computed Tomography Scanning

    PubMed Central

    Kim, Jae Hee; Jung, Dong Ju; Kim, Hyo Seong; Kim, Chang Hyun

    2014-01-01

    Background The septal cartilage is the most useful donor site for autologous cartilage graft material in rhinoplasty. For successful nasal surgery, it is necessary to understand the developmental process of the nasal septum and to predict the amount of harvestable septal cartilage before surgery. Methods One hundred twenty-three Korean patients who underwent three-dimensional (3D) facial bone computed tomography (CT) were selected for evaluation of the midsagittal view of the nasal septum. Multiple parameters such as the area of each component of the nasal septum and the amount of harvestable septal cartilage were measured using Digimizer software. Results The area of the total nasal septum showed rapid growth until the teenage years, but thereafter no significant change throughout the lifetime. However, the development of the septal cartilage showed a gradual decline due to ossification changes with aging after puberty in spite of a lack of change in the total septal area. The area of harvestable septal cartilage in young adults was 549.84±151.26 mm2 and decreased thereafter with age. Conclusions A 3D facial bone CT scan can provide valuable information on the septal cartilage graft before rhinoplasty. Considering the developmental process of the septal cartilage identified in this study, septal surgery should not be performed until puberty due to the risk of nasal growth impairment. Furthermore, in elderly patients who show a decreased cartilage area due to ossification changes, septal cartilage harvesting should be performed carefully due to the risk of saddle nose deformity. PMID:24665426

  4. Monitoring the glioma tropism of bone marrow–derived progenitor cells by 2-photon laser scanning microscopy and positron emission tomography

    PubMed Central

    Hasenbach, Kathy; Wiehr, Stefan; Herrmann, Caroline; Mannheim, Julia; Cay, Funda; von Kürthy, Gabriele; Bolmont, Tristan; Grathwohl, Stefan A.; Weller, Michael; Lengerke, Claudia; Pichler, Bernd J.; Tabatabai, Ghazaleh

    2012-01-01

    Intracerebral experimental gliomas attract intravenously injected murine or human bone marrow–derived hematopoietic progenitor and stem cells (HPC) in vitro, ex vivo, and in vivo, indicating that these progenitor cells might be suitable vehicles for a cell-based delivery of therapeutic molecules to malignant gliomas. With regard to therapeutic application, it is important to investigate cell fates in vivo (i.e., the time-dependent intratumoral and systemic distribution after intravenously injection). Conventional histological analysis has limitations in this regard because longitudinal monitoring is precluded. Here, we used 2-photon laser scanning microscopy (2PLSM), positron emission tomography (PET), and MRI to study the fate of intravenously injected HPC carrying fluorescence, bioluminescence, and PET reporter genes in glioma-bearing mice. Our 2PLSM-based monitoring studies revealed that HPC homing to intracerebral experimental gliomas occurred already within the first 6 h and was most efficient within the first 24 h after intravenous injection. The highest PET signals were detected in intracerebral gliomas, whereas the tracer uptake in other organs, notably spleen, lung, liver, and muscle, remained at background levels. The results have important implications for designing schedules for therapeutic cell-based anti-glioma approaches. Moreover, the PET reporter-based imaging technique will allow noninvasive monitoring of cell fate in future cell-based therapeutic antiglioma approaches. PMID:22298526

  5. TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

    SciTech Connect

    Perk, T; Bradshaw, T; Muzahir, S; Jeraj, R; Meyer, E

    2014-06-15

    Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate

  6. Bone mineral density test

    MedlinePlus

    ... test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis-BMD ... common and accurate way uses a dual-energy x-ray absorptiometry (DEXA) scan. DEXA uses low-dose x- ...

  7. Basic bone radiology

    SciTech Connect

    Griffiths, H.J.

    1987-01-01

    This clinical book surveys the skeletal system as seen through radiological imaging. It emphasizing abnormalities, disease, and trauma, and includes vital information on bones, bone growth, and the cells involved in bone pathology. It covers many bone diseases and injuries which are rarely covered in medical texts, as well as descriptions of radiologic procedures that specifically relate to the skeleton. This edition includes many illustrations, information on MR imaging and CT scanning, and discussions of osteoporosis, dysplasias, and metabolic bone disease.

  8. Radioisotope scanning in osseous sarcoidosis

    SciTech Connect

    Rohatgi, P.K.

    1980-01-01

    Technetium-99m (/sup 99m/Tc)-labeled pyrophosphate or diphosphonate compounds and gallium-67 citrate (/sup 67/Ga) are two radionuclide scanning agents that are in widespread use in clinical practice. Technetium-99m pyrophosphate is used extensively for bone scanning to detect metastatic bone disease, benign bone tumors, osteomyelitis, benign hypertrophic osteoarthropathy, and Paget's disease. Only two reports describe abnormal /sup 99m/Tc/ pyrophosphate bone scans in four patients with osseous sarcoidosis. Gallium-67 scans are used primarily to localize neoplastic or inflammatory lesions anywhere in the body. In recent years /sup 67/Ga scans have also been used to detect the presence of both pulmonary and extrapulmonary sarcoidosis, but there are no reports describing abnormal uptake of gallium in patients with osseous sarcoidosis. This report describes experience with radioisotope scanning in two patients with osseous sarcoidosis.

  9. Studies in skeletal tracer kinetics. V: Computer-simulated Tc-99m (Sn)MDP bone-scan changes in some systemic disorders: concise communication

    SciTech Connect

    Charkes, N.D.; Makler, P.T. Jr.

    1981-07-01

    Using compartmental analysis techniques, we modeled the biodistribution of Tc-99m(Sn)methylene diphosphonate in humans on a computer, and by selectively perturbing appropriate rate constants, we simulated changes in contrast between bone and soft tissue in a number of systemic disorders. The model predicts low contrast in patients with moderate to marked edema, obesity, congestive heart failure or decreased cardiac output states and high contrast with as little as 25% increase in bone avidity for the tracer. In acute renal failure without fluid-volume imbalance, image contrast should be normal. The model predicts greater contrast shortly after injection in patients with increased cardiac output, skeletal blood flow, or bone avidity; images made at these times would be indistinguishable. These simulations are in keeping with reports in the literature of bone images and bone-to-soft tissue ratios in many of these conditions, suggesting that modeling studies could play an important role image interpretation.

  10. Studies in skeletal tracer kinetics. V. Computer-simulated Tc-99m(Sn)MDP bone-scan changes in some systemic disorders: concise communication

    SciTech Connect

    Charkes, N.D.; Makler, P.T. Jr.

    1981-07-01

    Using compartmental analysis techniques, we modeled the biodistribution of Tc-99m(Sn)methylene diphosphonate in humans on a computer, and by selectively perturbing appropriate rate constants, we simulated changes in contrast between bone and soft tissue in a number of systemic disorders. The model predicts low contrast in patients with moderate to marked edema, obesity, congestive heart failure, or decreased cardiac output states and high contrast with as little as 25% increase in bone avidity for the tracer. In acute renal failure without fluid-volume imbalance, image contrast should be normal. The model predicts greater contrast shortly after injection in patients with increased cardiac output, skeletal blood flow, or bone avidity; images made at these times would be indistinguishable. These simulations are in keeping with reports in the literature of bone images and bone-to-soft tissue ratios in many of these conditions, suggesting that modeling studies could play an important role in image interpretation.

  11. Radionuclide bone imaging

    SciTech Connect

    Bassett, L.W.; Gold, R.H.; Webber, M.M.

    1981-12-01

    Radionuclide bone imaging of the skeleton, now well established as the most important diagnostic procedure in detecting bone metastases, is also a reliable method for the evaluation of the progression or regression of metastatic bone disease. The article concentrates on the technetium-99m agents and the value of these agents in the widespread application of low-dose radioisotope scanning in such bone diseases as metastasis, osteomyelitis, trauma, osteonecrosis, and other abnormal skeletal conditions.

  12. The Effect of Systemic Delivery of Aminoguanidine versus Doxycycline on the Resorptive Phase of Alveolar Bone Following modified Widman Flap in Diabetic Rats: A Histopathological and Scanning Electron Microscope (SEM) study

    PubMed Central

    Tella, E; Aldahlawi, S; Eldeeb, A; El Gazaerly, H

    2014-01-01

    Objectives Aminoguanidine (guanylhydrazinehydrochloride) is a drug that prevents many of the classical systemic complications of diabetes including diabetic osteopenia through its inhibitory activity on the accumulation of advanced glycation end –products (AGEs). The aim of the present study was to evaluate the effectiveness of aminoguanidine versus doxycycline in reducing alveolar bone resorption following mucoperiosteal flap in diabetic rats, using the conventional histopathology and scanning electron microscope (SEM). Methods Twenty-seven male albino rats were used in this study. Periodontal defects were induced experimentally on lower anterior teeth. All rats were subjected to induction of diabetes, by IV injection of the pancreatic B-cells toxin alloxan monohydrate. After eight weeks following the establishment of periodontal defects in all rats, the ligation was removed and 3 rats were scarified as negative control (group 1). The remaining animals were divided into three group based on treatment applied following mucoperiosteal flap surgery. Group 2 received saline treatment only, group 3 received doxycycline periostat (1.5 mg/kg/day) for 3 weeks, and group 4 received aminoguanidine (7.3 mmol/kg) for 3 weeks. The fasting glucose level was measured weekly post operatively. After 21 days all rats were sacrificed. Three anterior parts of the mandible of each group was prepared for histopathological examination and two parts were prepared for SEM. Results Aminoguanidine treated group (group 4) showed statistically significant increased new bone formation, higher number of osteoblasts and decrease osteoclasts number, resorptive lacunae and existing inflammatory cell infiltration as compared to positive control group (group 2) (P<0.05). Doxycycline was also effective in reducing bone loss as documental by histopathological study. Conclusion The present study showed that aminoguanidine was significantly effective in reducing alveolar bone loss and can modify the

  13. Bone Cancer - Multiple Languages: MedlinePlus

    MedlinePlus

    ... Bone Scan (Arabic) العربية Bilingual PDF Health Information Translations Chinese - Simplified (简体中文) Bone Scan 骨扫描 - 简体中文 (Chinese - Simplified) Bilingual PDF Health Information Translations Chinese - Traditional (繁體中文) Bone Scan 骨骼掃描 - 繁體中文 (Chinese - ...

  14. Thyroid scan

    MedlinePlus

    ... thyroid; Radioactive iodine uptake and scan test - thyroid; Nuclear scan - thyroid ... the test. Ask your provider or the radiology/nuclear medicine team performing the scan about taking precautions.

  15. Nuclear Scans

    MedlinePlus

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  16. Preoperative nuclear scans in patients with melanoma

    SciTech Connect

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-05-15

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive.

  17. Bone imaging in sports medicine.

    PubMed

    Shikare, S; Samsi, A B; Tilve, G H

    1997-01-01

    Increased participation in sports by the general public leads to increase in sports induced injuries including stress fractures, shin splints, arthritis and host of musculotendenous maladies. We have studied twenty patients referred from sports clinic for bone scanning to evaluate clinically difficult problems. It showed stress fracture in twelve patients, bilateral shin splint in five patients and normal bone scan in three patients. Present study highlights the utility of bone imaging for the diagnosis of various sports injuries in sports medicine.

  18. Bone Grafts

    MedlinePlus

    A bone graft transplants bone tissue. Surgeons use bone grafts to repair and rebuild diseased bones in your hips, knees, ... fractures or cancers. Once your body accepts the bone graft, it provides a framework for growth of new, ...

  19. Bone Diseases

    MedlinePlus

    ... avoid smoking and drinking too much alcohol. Bone diseases can make bones easy to break. Different kinds ... break Osteogenesis imperfecta makes your bones brittle Paget's disease of bone makes them weak Bones can also ...

  20. Hypercalciuric Bone Disease

    NASA Astrophysics Data System (ADS)

    Favus, Murray J.

    2008-09-01

    Hypercalciuria plays an important causal role in many patients with calcium oxalate (CaOx) stones. The source of the hypercalciuria includes increased intestinal Ca absorption and decreased renal tubule Ca reabsorption. In CaOx stone formers with idiopathic hypercalciuria (IH), Ca metabolic balance studies have revealed negative Ca balance and persistent hypercalciuria in the fasting state and during low dietary Ca intake. Bone resorption may also contribute to the high urine Ca excretion and increase the risk of bone loss. Indeed, low bone mass by DEXA scanning has been discovered in many IH patients. Thiazide diuretic agents reduce urine Ca excretion and may increase bone mineral density (BMD), thereby reducing fracture risk. Dietary Ca restriction that has been used unsuccessfully in the treatment of CaOx nephrolithiasis in the past may enhance negative Ca balance and accelerate bone loss. DEXA scans may demonstrate low BMD at the spine, hip, or forearm, with no predictable pattern. The unique pattern of bone histologic changes in IH differs from other causes of low DEXA bone density including postmenopausal osteoporosis, male hypogonadal osteoporosis, and glucocorticoid-induced osteoporosis. Hypercalciuria appears to play an important pathologic role in the development of low bone mass, and therefore correction of urine Ca losses should be a primary target for treatment of the bone disease accompanying IH.

  1. Aneurysmal bone cyst of the ethmoid bone

    PubMed Central

    Janjua, Noor; Cresswell, Manuela; Sharma, Rishi; Maheshwar, Arcot

    2014-01-01

    A 90-year-old woman presented with headache and diplopia, and a mass in the nasal cavity and paranasal sinuses was found on CT scan. The patient underwent examination under anaesthesia showing a mass arising from the ethmoid, apparently from the nasal septum. Biopsies taken showed an aneurysmal bone cyst. The patient opted against surgery and has been managed conservatively. A second CT scan 4 years later showed significant increase in size. PMID:24706701

  2. Fiber-matrix interface studies on bioabsorbable composite materials for internal fixation of bone fractures. II. A new method using laser scanning confocal microscopy.

    PubMed

    Slivka, M A; Chu, C C

    1997-12-01

    In this study, a new visual characterization method was developed using laser scanning confocal microscopy (LSCM) to study morphologic properties, particularly at the fiber-matrix interface, by optical sectioning of bioabsorbable single-fiber composites. The interface gap width (IGW) between the fiber and matrix, and the changes in IGW after in vitro hydrolysis, named the gap rate (Rg), were measured from images obtained using the LSCM. Higher values for IGW and Rg showed faster degradation of the fiber-matrix interface. These parameters were used to investigate the effects of strain, wicking, different reinforcing fibers, and gamma-irradiation on the fiber-matrix interface morphology. The component materials used were nonbioabsorbable AS4 carbon (C) fibers, bioabsorbable calcium phosphate (CaP), poly(glycolic acid) (PGA), and chitin fibers, and bioabsorbable poly(L-lactic acid) (PLLA) matrix. The application of strain on CaP/PLLA composites increased the IGW up to about 15%, after which there was no change up to 25%. The Rg for CaP/PLLA composites with the fiber ends exposed in vitro (permitting wicking) was greater than for CaP/PLLA with the fiber ends embedded completely within the matrix (preventing wicking). Open-end C/PLLA composites had the slowest rate of interface degradation in vitro, followed by chitin/PLLA, PGA/PLLA, and CaP/PLLA. The exposure of closed-end CaP/PLLA composites to 4 Mrad of gamma-irradiation, in air at room temperature or in vaccuum at 77K, accelerated the rate of interface degradation in vitro. In conclusion, an effective new visual characterization method was developed using LSCM, and it was used to show that (a) moderate strain could accelerate the degradation of the interface, (b) fiber-matrix interface wicking could accelerate the rate of degradation of the interface, (c) the rate of interface degradation depends on the type of fiber used, and (d) gamma-irradiation could accelerate the rate of interface degradation. Furthermore, the

  3. Bone marrow metastases from alveolar rhabdomyosarcoma with impressive FDG PET/CT finding but less-revealing bone scintigraphy.

    PubMed

    Yang, Jigang; Zhen, Lishi; Zhuang, Hongming

    2013-12-01

    An 18F-FDG PET/CT scan was performed in a 26-year-old man with a known alveolar rhabdomyosarcoma for staging. The PET/CT scan showed abnormally increased FDG activity involving almost all bones in the imaged regions. In contrast, 99mTc-MDP whole-body bone scan demonstrated only very limited bone metastases.

  4. The NaNO3-KNO3 phase diagram

    NASA Astrophysics Data System (ADS)

    Benages-Vilau, R.; Calvet, T.; Cuevas-Diarte, M. A.; Oonk, H. A. J.

    2016-01-01

    Many papers have been published in relation to the NaNO3-KNO3 phase diagram determination in the last 160 years. These papers fall in two categories: (1) the solid-liquid equilibrium is assumed to be of the eutectic type, and (2) the solid-liquid equilibrium is considered as a loop with a minimum. The discordance between the two views is related to the slow transition kinetics that complicate the assessment of thermal 'fluctuations', and also to the appearance of a metastable form of potassium nitrate. The main result of this paper is the experimental phase diagram constructed with new experimental data so that we can assure that the second option is correct. This phase diagram is defined by a eutectoid invariant, an asymmetric immiscibility gap and a continuous solid solution with a minimum of melting point. Additionally, the ABθ model simulates correctly the experimental piece of evidence.

  5. Synthesis of Dense BC3 Phases under High-Pressure and High-Temperature

    NASA Astrophysics Data System (ADS)

    Zinin, P.; Ming, L.; Acosta, T.; Jia, R.; Hellebrand, E.; Ishii, H.

    2010-12-01

    strong peak at 1180 cm-1. The c-BC3 phase was also examined with an aberration-corrected (scanning) transmission electron microscope. A thin section of c-BC3 was removed by the Focus Ion Beam (FIB) instrument and thinned to electron transparency (~90 nm) for electron diffraction measurement. The electron diffraction pattern of the c-BC3 measured from the thin section shows the same diamond structure as revealed by the synchrotron XRD. The composition of the new phase is determined from Electron Energy Loss Spectroscopy (EELS) measurements. The value of the C/B ratio was found to be around 3 (2.8 ± 0.3).

  6. MRI Scans

    MedlinePlus

    Magnetic resonance imaging (MRI) uses a large magnet and radio waves to look at organs and structures inside your body. Health care professionals use MRI scans to diagnose a variety of conditions, from torn ...

  7. WBC scan

    MedlinePlus

    Leukocyte scan ... will be taken from one of your veins. White blood cells are separated from the rest of the blood ... 111. These cells are considered tagged. The tagged white blood cells are injected back into your body through a ...

  8. Diphosphonates in the evaluation of metabolic bone disease.

    PubMed

    Fogelman, I; Smith, M L

    1982-03-01

    The bone scan may be of value in the assessment of patients with metabolic bone disease. However the superiority of the bone scan when compared to radiology in conditions such as renal osteodystrophy, osteomalacia, primary hyperparathyroidism, and osteoporosis requires substantiation with the newer radiopharmaceuticals which have a higher affinity for bone. Two methods of quantitating skeletal uptake of tracer have been assessed to try to remove the subjective aspect of bone scan evaluation. Measurements of bone to soft tissue ratios have proved clinically disappointing, but 24 hour whole body retention of diphosphonate appears to provide a sensitive index of increased bone turnover.

  9. Unsuspected pregnancy during bone scintigraphy

    SciTech Connect

    Oates, E.; Ramberg, K.; Becker, J.L. )

    1990-06-01

    Despite careful screening efforts to avoid it, nuclear medicine studies are unintentionally performed on pregnant patients. Three-phase bone scanning is a common procedure performed in women of child-bearing age. Unsuspected pregnancies have been discovered on the flow and early view of the pelvis. The authors present a case of a pregnant girl, aged 15, who had a bone scan. They explain how this occurred and how they plan to prevent a recurrence. Dosimetry for the fetus also is considered.

  10. Nuclear Scans - Multiple Languages: MedlinePlus

    MedlinePlus

    ... Bone Scan (Arabic) العربية Bilingual PDF Health Information Translations PET (Positron Emission Tomography) Scan (Arabic) العربية Bilingual PDF Health Information Translations Stress Muga (Arabic) العربية Bilingual PDF Health Information ...

  11. Living Bones, Strong Bones

    NASA Video Gallery

    In this classroom activity, engineering, nutrition, and physical activity collide when students design and build a healthy bone model of a space explorer which is strong enough to withstand increas...

  12. Bone Tumor

    MedlinePlus

    ... most common types of primary bone cancer are: • Multiple myeloma. Multiple myeloma is the most common primary bone cancer. It ... Any bone can be affected by this cancer. Multiple myeloma affects approximately six people per 100,000 each ...

  13. Bone Cancer

    MedlinePlus

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  14. Perineal scanning.

    PubMed

    Jeanty, P; d'Alton, M; Romero, R; Hobbins, J C

    1986-10-01

    Although various techniques have been described to aid in the ultrasound diagnosis of placenta previa and incompetent cervix, these maneuvers depend on the precise identification of the internal cervical os, a feat which is notoriously difficult to accomplish consistently. In an attempt to get a closer view of the cervix we tried another approach. This simple technique of perineal scanning has the potential to help considerably with these problems. PMID:3530265

  15. Adult hemolytic-uremic syndrome and bone marrow necrosis

    SciTech Connect

    Hicks, C.B.; Redmond, J. III

    1984-11-01

    A case is reported of adult hemolytic-uremic syndrome in which massive bone marrow necrosis developed, a previously undescribed complication. Technetium-99m minicolloid scanning and indium-111 bone marrow scans were used to demonstrate lack of bone marrow activity in the patient. 11 references, 2 figures.

  16. Bone and bone turnover.

    PubMed

    Crofton, Patricia M

    2009-01-01

    Children with cancer are exposed to multiple influences that may adversely affect bone health. Some treatments have direct deleterious effects on bone whilst others may have indirect effects mediated through various endocrine abnormalities. Most clinical outcome studies have concentrated on survivors of acute lymphoblastic leukaemia (ALL). There is now good evidence that earlier treatment protocols that included cranial irradiation with doses of 24 Gy or greater may result in growth hormone deficiency and low bone mineral density (BMD) in the lumbar spine and femoral neck. Under current protocols, BMD decreases during intensive chemotherapy and fracture risk increases. Although total body BMD may eventually return to normal after completion of chemotherapy, lumbar spine trabecular BMD may remain low for many years. The implications for long-term fracture risk are unknown. Risk factors for low BMD include high dose methotrexate, higher cumulative doses of glucocorticoids, male gender and low physical activity. BMD outcome in non-ALL childhood cancers has been less well studied but there is evidence that survivors of childhood brain or bone tumours, and survivors of bone marrow transplants for childhood malignancy, all have a high risk of long-term osteopenia. Long-term follow-up is required, with appropriate treatment of any endocrine abnormalities identified.

  17. BoneJ: Free and extensible bone image analysis in ImageJ.

    PubMed

    Doube, Michael; Kłosowski, Michał M; Arganda-Carreras, Ignacio; Cordelières, Fabrice P; Dougherty, Robert P; Jackson, Jonathan S; Schmid, Benjamin; Hutchinson, John R; Shefelbine, Sandra J

    2010-12-01

    Bone geometry is commonly measured on computed tomographic (CT) and X-ray microtomographic (μCT) images. We obtained hundreds of CT, μCT and synchrotron μCT images of bones from diverse species that needed to be analysed remote from scanning hardware, but found that available software solutions were expensive, inflexible or methodologically opaque. We implemented standard bone measurements in a novel ImageJ plugin, BoneJ, with which we analysed trabecular bone, whole bones and osteocyte lacunae. BoneJ is open source and free for anyone to download, use, modify and distribute.

  18. Effect of strontium-containing hydroxyapatite bone cement on bone remodeling following hip replacement.

    PubMed

    Ni, Guo X; Lin, Jian H; Chiu, Peter K Y; Li, Zhao Y; Lu, William W

    2010-01-01

    It is uncertain whether the use of bioactive bone cement has any beneficial effect on local bone adaptation following hip replacement. In this study, twelve goats underwent cemented hip hemiarthroplasty unilaterally, with either PMMA bone cement or strontium-containing hydroxyapatite (Sr-HA) bioactive bone cement. Nine months later, the femoral cortical bones at different levels were analyzed by microhardness testing and micro-CT scanning. Extensive bone remodeling was found at proximal and mid-levels in both PMMA and Sr-HA groups. However, with regard to the differences of bone mineral density, cortical bone area and bone hardness between implanted and non-implanted femur, less decreases were found in Sr-HA group than PMMA group at proximal and mid-levels, and significant differences were shown for bone area and hardness at proximal level. The results suggested that the use of Sr-HA cement might alleviate femoral bone remodeling after hip replacement. PMID:19728042

  19. Microwave drilling of bones.

    PubMed

    Eshet, Yael; Mann, Ronit Rachel; Anaton, Abby; Yacoby, Tomer; Gefen, Amit; Jerby, Eli

    2006-06-01

    This paper presents a feasibility study of drilling in fresh wet bone tissue in vitro using the microwave drill method [Jerby et al, 2002], toward testing its applicability in orthopaedic surgery. The microwave drill uses a near-field focused energy (typically, power under approximately 200 W at 2.45-GHz frequency) in order to penetrate bone in a drilling speed of approximately 1 mm/s. The effect of microwave drilling on mechanical properties of whole ovine tibial and chicken femoral bones drilled in vitro was studied using three-point-bending strength and fatigue tests. Properties were compared to those of geometrically similar bones that were equivalently drilled using the currently accepted mechanical rotary drilling method. Strength of mid-shaft, elastic moduli, and cycles to failure in fatigue were statistically indistinguishable between specimen groups assigned for microwave and mechanical drilling. Carbonized margins around the microwave-drilled hole were approximately 15% the hole diameter. Optical and scanning electron microscopy studies showed that the microwave drill produces substantially smoother holes in cortical bone than those produced by a mechanical drill. The hot spot produced by the microwave drill has the potential for overcoming two major problems presently associated with mechanical drilling in cortical and trabecular bone during orthopaedic surgeries: formation of debris and rupture of bone vasculature during drilling.

  20. Head CT scan

    MedlinePlus

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...

  1. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination

    SciTech Connect

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Majoie, Charles B.L.M.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2004-10-01

    In maximum intensity projection (MIP) images of CT angiography (CTA) scans, the arteries are often obscured by bone. A bone removal method is presented that uses an additional, nonenhanced scan to create a mask of the bone by thresholding and dilation. After registration of the CTA scan and the additional scan, the bone in the CTA scan is masked. As the cervical area contains bones that can move with respect to each other, these bones are separated first using a watershed algorithm, and then registered individually. A phantom study was performed to evaluate and quantify the tradeoff between the removal of the bone and the preservation of the arteries contiguous to the bone. The influence of algorithm parameters and scan parameters was studied. The method was clinically evaluated with data sets of 35 patients. Best results were obtained with a threshold of 150 HU and a dilation of 8 in-plane voxels and two out-of-plane voxels. The mean width of the soft tissue layer, which is also masked, was approximately 1 mm. The mAs value of the nonenhanced scan could be reduced from 250 mAs to 65 mAs without a loss of quality. In 32 cases the bones were registered correctly and removed completely. In three cases the bone separation was not completely successful, and consequently the bone was not completely removed. The piecewise matched mask bone elimination method proved to be able to obtain MIP images of the cervical arteries free from overprojecting bone in a fully automatic way and with only a slight increase of radiation dose.

  2. Low Bone Density

    MedlinePlus

    ... Density Exam/Testing › Low Bone Density Low Bone Density Low bone density is when your bone density ... people with normal bone density. Detecting Low Bone Density A bone density test will determine whether you ...

  3. Early postoperative bone scintigraphy in the evaluation of microvascular bone grafts in head and neck reconstruction

    PubMed Central

    Schuepbach, Jonas; Dassonville, Olivier; Poissonnet, Gilles; Demard, Francois

    2007-01-01

    Background Bone scintigraphy was performed to monitor anastomotic patency and bone viability. Methods In this retrospective study, bone scans were carried out during the first three postoperative days in a series of 60 patients who underwent microvascular bone grafting for reconstruction of the mandible or maxilla. Results In our series, early bone scans detected a compromised vascular supply to the bone with high accuracy (p < 10-6) and a sensitivity that was superior to the sensitivity of clinical monitoring (92% and 75% respectively). Conclusion When performing bone scintigraphy during the first three postoperative days, it not only helps to detect complications with high accuracy, as described in earlier studies, but it is also an additional reliable monitoring tool to decide whether or not microvascular revision surgery should be performed. Bone scans were especially useful in buried free flaps where early postoperative monitoring depended exclusively on scans. According to our experience, we recommend bone scans as soon as possible after surgery and immediately in cases suspicious of vascularized bone graft failure. PMID:17448223

  4. Radionuclide evaluation of nonmalignant bone disorders

    SciTech Connect

    Winzelberg, G.G.

    1983-02-01

    Recent advances in nuclear imaging have improved the noninvasive evaluation of patients with nonmalignant bone disorders. When bone scanning agents are combined with bone marrow scanning agents and gallium-67 scintigraphy, a more accurate diagnosis can be obtained. By selecting the appropriate imaging sequence, it is often possible to distinguish cellulitis from underlying osteomyelitis. In patients with total hip replacements, it may be possible to separate postsurgical changes from prosthetic loosening or infection. Stress fractures in joggers may be detected by radionuclide bone scintigraphy before radiographs become abnormal. These nuclear imaging procedures can be done in most hospitals.

  5. Bone Markers

    MedlinePlus

    ... Alkaline Phosphatase; Osteocalcin; P1NP; Procollagen Type 1 N-Terminal Propeptide Formal name: Biochemical Markers of Bone Remodeling ... tests for evaluating bone turnover: C-telopeptide (C-terminal telopeptide of type 1 collagen (CTx)) – a marker ...

  6. Bone Infections

    MedlinePlus

    ... of the body, bones can get infected. The infections are usually bacterial, but can also be fungal. ... bloodstream. People who are at risk for bone infections include those with diabetes, poor circulation, or recent ...

  7. Pelvic CT scan

    MedlinePlus

    CAT scan - pelvis; Computed axial tomography scan - pelvis; Computed tomography scan - pelvis; CT scan - pelvis ... creates detailed pictures of the body, including the pelvis and areas near the pelvis. The test may ...

  8. Leg CT scan

    MedlinePlus

    CAT scan - leg; Computed axial tomography scan - leg; Computed tomography scan - leg; CT scan - leg ... on film. Three-dimensional (3D) models of the leg can be created by adding the slices together. ...

  9. Abscess scan - radioactive

    MedlinePlus

    Radioactive abscess scan; Abscess scan; Indium Scan; Indium-labelled white blood cell scan ... the white blood cells are tagged with a radioactive substance called indium. The cells are then injected ...

  10. The white blood cell scan in orthopedics

    SciTech Connect

    Propst-Proctor, S.L.; Dillingham, M.F.; McDougall, I.R.; Goodwin, D.

    1982-08-01

    A new nuclear scanning technique was found more specific for bone, joint, and soft tissue infections than any previously described scanning technique. The leukocyte scan, whereby a patient's own cells are labeled with a radioactive tagging agent (/sup 111/In oxine), can distinguish an active infectious process from other pain-inducing conditions. Ninety-seven /sup 111/In labeled autologous leukocyte scans were performed in 88 patients. The findings in 17 of 40 patients scanned for possible acute osteomyelitis, six of nine for suspected septic arthritis, and six for possible soft tissue infections, were positive. Subsequent clinical courses verified the infectious nature of these processes in all patients. Patients who had chronic osteomyelitis (14), bony metastases (four patients), heterotopic ossification (three), and degenerative arthritis (two) demonstrated negative findings. Of the seven patients scanned for acute long-bone fractures, one demonstrated positive findings. Nine scans demonstrated positive findings without determined causes. The leukocyte scan is a useful addition to the diagnostic tools of the orthopedic surgeon.

  11. Postradiation atrophy of mature bone

    SciTech Connect

    Erguen, H.; Howland, W.J.

    1980-01-01

    The growing number of oncological patients subjected to radiotherapy require the diagnostic radiologist to be aware of expected bone changes following irradiation and the differentiation of this entity from metastasis. The primary event of radiation damage to bone is atrophy and true necrosis of bone is uncommon. The postradiation atrophic changes of bone are the result of combined cellular and vascular damage, the former being more important. The damage to the osteoblast resulting in decreased matrix production is apparently the primary histopathologic event. Radiation damaged bone is susceptible to superimposed complications of fracture, infection, necrosis, and sarcoma. The primary radiographic evidence of atrophy, localized osteopenia, is late in appearing, mainly because of the relative insensitivity of radiographs in detecting demineralization. Contrary to former views, the mature bone is quite radiosensitive and reacts quickly to even small doses of radiation. In vivo midrodensitometric analysis and radionuclide bone and bone marrow scans can reveal early changes following irradiation. The differentiation of postirradiation atrophy and metastasis may be difficult. Biopsy should be the last resort because of the possibility of causing true necrosis in atrophic bone by trauma and infection.

  12. Postradiation atrophy of mature bone

    SciTech Connect

    Ergun, H.; Howland, W.J.

    1980-01-01

    The growing number of oncological patients subjected to radiotherapy require the diagnostic radiologist to be aware of expected bone changes following irradiation and the differentiation of this entity from metastasis. The primary event of radiation damage to bone is atrophy and true necrosis of bone is uncommon. The postradiation atrophic changes of bone are the result of combined cellular and vascular damage, the former being more important. The damage to the osteoblast resulting in decreased matrix production is apparently the primary histopathologic event. Radiation damaged bone is susceptible to superimposed complications of fracture, infection, necrosis, and sarcoma. The primary radiographic evidence of atrophy, localized osteopenia, is late in appearing, mainly because of the relative insensitivity of radiographs in detecing demineralization. Contrary to former views, the mature bone is quite radiosensitive and reacts quickly to even small doses of radiation. In vivo midrodensitometric analysis and radionuclide bone and bone marrow scans can reveal early changes following irradiation. The differentiation of postirradiation atrophy and metastasis may be difficult. Biopsy should be the last resort because of the possibility of causing true necrosis in atrophic bone by trauma and infection.

  13. Nuclear scanning in necrotizing progressive ''malignant'' external otitis

    SciTech Connect

    Parisier, S.C.; Lucente, F.E.; Som, P.M.; Hirschman, S.Z.; Arnold, L.M.; Roffman, J.D.

    1982-09-01

    The usefulness of radionuclear scanning in the treatment of 18 patients with necrotizing progressive ''malignant'' external otitis is discussed. A Tc 99-m bone scan, a valuable test since results are positive in early cases of osteomyelitis of the temporal bone and base of skull, showed increased uptake in all 18 patients. In 6 patients, Ga-67 citrate scans were obtained at the start of therapy and at 5-6 week intervals thereafter. The serial gallium scans were useful in evaluating the effectiveness of therapy since the uptake decrease with control of infection.

  14. A Boon for Bone Research

    NASA Technical Reports Server (NTRS)

    1996-01-01

    NASA studies for astronaut health in long-term space missions led to the development of the Mechanical Response Tissue Analyzer (MRTA), a research tool for astronaut disuse, osteoporosis and related bone disorders among the general population. Ames Research Center and Stanford University generated a workable device and with Gait Scan, Inc., refined and commercialized it. The MRTA is a portable dsinstrument that measures the bending stiffness of bones using electrically-induced vibration and detects and analyzes the frequencies of the resonating bone. Unlike some other methods, the MRTA uses no radiation and is fast, simple and relatively inexpensive.

  15. Bone and Gallium scintigraphy in primary malignant and benign bone tumors of the extremities

    SciTech Connect

    Sepahdari, S.; Martin, W.B.; Ryan, J.; Simon, M.; Kirchner, P.

    1985-05-01

    A six yer prospective evaluation of 129 patients suspected of having a primary bone tumor included Tc-99m MDP bone scintigraphy followed by Ga-67 imaging at 48-72 hours. Blood pool images were part of bone scintigraphy in nearly half of the patients. Extent and intensity of tracer uptake in tumor and adjacent bone and joints were recorded for each tracer by two observers blind to the diagnosis. Tissue samples obtained in every patient by biopsy or tumor excision after scintigraphy, revealed 72 malignant and 57 benign bone tumors. The bone scan was positive in 95% (69/72) of malignancies. The scintigraphic intensity of benign and malignant lesions was comparable with both Tc-99m MDP and Ga-67. On the other hand, bone scintigraphy showed 72% (52/72) of bone malignancies to have abnormal proximal and distal bone/joint uptake whereas the Ga-67 images revealed this in only 6% (4/65) of malignancies. Benign lesions manifested this enhanced contiguous bone/joint uptake on only 8% (5/55) of bone and 0% of Ga-67 scans. This study concludes positive bone, blood pool, or Ga-67 images have less specificity for malignancy than the presence of increased Tc-99m MDP deposition in a contiguous bone/joint, but negative scintigraphic results strongly favor a benign lesion. Ga-67 was more accurate than Tc-99m MDP in portraying intraosseous extent of malignant tumors; however, this is now preferably done with C.T.

  16. Calcar bone graft

    SciTech Connect

    Bargar, W.L.; Paul, H.A.; Merritt, K.; Sharkey, N.

    1986-01-01

    A canine model was developed to investigate the use of an autogeneic iliac bone graft to treat the calcar deficiency commonly found at the time of revision surgery for femoral component loosening. Five large male mixed-breed dogs had bilateral total hip arthroplasty staged at three-month intervals, and were sacrificed at six months. Prior to cementing the femoral component, an experimental calcar defect was made, and a bicortical iliac bone graft was fashioned to fill the defect. Serial roentgenograms showed the grafts had united with no resorption. Technetium-99 bone scans showed more uptake at three months than at six months in the graft region. Disulfine blue injection indicated all grafts were perfused at both three and six months. Thin section histology, fluorochromes, and microradiographs confirmed graft viability in all dogs. Semiquantitative grading of the fluorochromes indicated new bone deposition in 20%-50% of each graft at three months and 50%-80% at six months. Although the calcar bone graft was uniformly successful in this canine study, the clinical application of this technique should be evaluated by long-term results in humans.

  17. Multiple atypical bone involvement in sarcoidosis.

    PubMed

    Mañá, J; Segarra, M I; Casas, R; Mairal, L; Fernández-Nogués, F

    1993-02-01

    We describe a patient with right paratracheal and left hilar lymph nodes detected by chance on chest radiography that followed a spontaneous remission. However, a few months later she complained of multiple scalp nodules. Skull roentgenogram and computerized tomogram scan showed multiple osteolytic lesions with increased uptake in bone and gallium scans. Lytic lesions were also detected in her right mandibular bone and right clavicle. Noncaseating granulomas were demonstrated in skull and cervical lymph node biopsies. PMID:8474084

  18. [Bone diseases].

    PubMed

    Uebelhart, Brigitte; Rizzoli, René

    2016-01-13

    Calcium intake shows a small impact on bone mineral density and fracture risk. Denosumab is a more potent inhibitor of bone resorption than zoledronate. Abaloparatide, PTHrP analog, increases bone mineral density and decreases fracture incidence. Teriparatide could be delivered via a transdermic device. Romosozumab and odanacatib improve calculated bone strength. Sequential or combined treatments with denosumab and teriparatide could be of interest, but not denosumab followed by teriparatide. Fibrous dysplasia, Paget disease and hypophosphatasia are updated, as well as atypical femoral fracture and osteonecrosis of the jaw.

  19. Gallbladder radionuclide scan

    MedlinePlus

    Radionuclide - gallbladder; Gallbladder scan; Biliary scan; Cholescintigraphy: HIDA; Hepatobiliary nuclear imaging scan ... small amount of morphine. This can help the radionuclide get into the gallbladder. The morphine may cause ...

  20. Coronary Calcium Scan

    MedlinePlus

    ... the NHLBI on Twitter. What Is a Coronary Calcium Scan? A coronary calcium scan is a test ... you have calcifications in your coronary arteries. Coronary Calcium Scan Figure A shows the position of the ...

  1. Talking Bones.

    ERIC Educational Resources Information Center

    Johnson, Jaclyn; Kassing, Sharon

    2002-01-01

    Describes cooperation with the Saint Louis Zoo to provide opportunities for elementary school students to learn about bones, how animals move, what they eat, and how much they grow. Uses biofacts which include bones, skulls, and other parts to make the laboratory a hands-on experience for students. (YDS)

  2. Bone Scintigraphic Findings in MRSA Osteomyelitis.

    PubMed

    Cornejo, Patricia; Mandell, Gerald A

    2016-02-01

    Methicillin-resistant Staphylococcus aureus osteomyelitis is a severe form of infection characterized by multifocal or multiple segmental osseous involvement and subperiosteal abscess formation with increased frequency of extraosseous complications including pyomyositis, septic thrombus, and septic arthritis. Bone scan showed long segment and/or multifocal involvement in 4 of 5 patients with areas of abnormal increased and decreased uptake. The clinical presentations included limp and/or pain. Joint involvement was seen in 4 cases. Bone scan abnormalities correlated well with MRI findings of severe and extensive bone disease, abscess formation, muscle, as well as joint and soft tissue involvement.

  3. Value of nuclear bone imaging in advanced prostatic cancer

    SciTech Connect

    Pollen, J.J.; Gerber, K.; Ashburn, W.L.; Schmidt, J.D.

    1981-02-01

    The nuclear bone scan is a highly sensitive means of detecting skeletal metastasis in patients with prostatic cancer. Serial bone imaging provides an accurate method to follow the response of osseous metastases to treatment and to detect relapsing disease in the skeleton. In selected instances the nuclear bone scan can provide information about vertebral metastases that can be important for planning palliative treatment of pain.

  4. Lyotropic liquid crystalline L3 phase silicated nanoporous monolithic composites and their production

    DOEpatents

    McGrath, Kathryn M.; Dabbs, Daniel M.; Aksay, Ilhan A.; Gruner, Sol M.

    2003-10-28

    A mesoporous ceramic material is provided having a pore size diameter in the range of about 10-100 nanometers produced by templating with a ceramic precursor a lyotropic liquid crystalline L.sub.3 phase consisting of a three-dimensional, random, nonperiodic network packing of a multiple connected continuous membrane. A preferred process for producing the inesoporous ceramic material includes producing a template of a lyotropic liquid crystalline L.sub.3 phase by mixing a surfactant, a co-surfactant and hydrochloric acid, coating the template with an inorganic ceramic precursor by adding to the L.sub.3 phase tetramethoxysilane (TMOS) or tetraethoxysilane (TEOS) and then converting the coated template to a ceramic by removing any remaining liquids.

  5. Metastatic Bone Disease

    MedlinePlus

    ... Bone Disease cont. Page ( 4 ) MBD vs. Primary Bone Cancer The diagnosis of metastatic bone disease should not ... from an unknown primary carcinoma or a primary bone cancer (sarcoma). For example, if an area of bone ...

  6. Spinal computed tomography scanning in the evaluation of metastatic disease

    SciTech Connect

    Redmond, J.; Spring, D.B.; Munderloh, S.H.; George, C.B.; Mansour, R.P.; Volk, S.A.

    1984-07-15

    Twenty patients with known metastatic cancer or high-risk primary cancer developed new lesions on Tc/sup 99m/ bone scans and had normal plain radiographs. Spinal computed tomography (CT) was performed on all new bone-scan-positive lesions in minimal examination time. Fifteen patients had extensive metastatic vertebral disease and received local radiotherapy. One patient with new metastatic vertebral disease on CT was treated only with chemotherapy and developed acute spinal cord compression. Four patients had discogenic disease or degenerative disease but no evidence of metastases. Radionuclide bone scans are more sensitive but less specific than plain radiographs in detecting early bone metastases. Early and accurate diagnosis of metastasis is particularly important in the axial spine to prevent epidural compression and fracture. Spinal CT is valuable for identifying the presence and extent of vertebral metastases, as well as the presence of benign disease in cancer patients.

  7. [Fractures of carpal bones].

    PubMed

    Lögters, T; Windolf, J

    2016-10-01

    Fractures of the carpal bones are uncommon. On standard radiographs fractures are often not recognized and a computed tomography (CT) scan is the diagnostic method of choice. The aim of treatment is to restore pain-free and full functioning of the hand. A distinction is made between stable and unstable carpal fractures. Stable non-displaced fractures can be treated conservatively. Unstable and displaced fractures have an increased risk of arthritis and non-union and should be stabilized by screws or k‑wires. If treated adequately, fractures of the carpal bones have a good prognosis. Unstable and dislocated fractures have an increased risk for non-union. The subsequent development of carpal collapse with arthrosis is a severe consequence of non-union, which has a heterogeneous prognosis.

  8. Radionuclide scanning in children with rhabdomyosarcoma

    SciTech Connect

    Weinblatt, M.E.; Miller, J.H.

    1981-01-01

    Radionuclide scintigraphy was performed in 46 children with rhabdomyosarcoma. Of the 63 radiologically confirmed sites of bone disease, 76% were detected by /sup 99m/Tc-labeled phosphate uptake. All 15 sites of hepatic involvement and eight of the nine cranial sites of disease exhibited isotope accumulation. Gallium 67 scans showed 57% of the 43 proven sites of disease, including four previously unsuspected areas. Twelve false-positive sites were obtained with gallium. Radionuclide scanning is a valuable aid in the diagnostic evaluation and management of childhood rhabdomyosarcoma.

  9. Bone marrow transplant

    MedlinePlus

    Transplant - bone marrow; Stem cell transplant; Hematopoietic stem cell transplant; Reduced intensity nonmyeloablative transplant; Mini transplant; Allogenic bone marrow transplant; Autologous bone marrow transplant; Umbilical ...

  10. Abdominal CT scan

    MedlinePlus

    Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... 2016:chap 133. Radiologyinfo.org. Computed tomography (CT) - abdomen and pelvis. Updated June 16, 2016. www.radiologyinfo. ...

  11. RBC nuclear scan

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  12. Calcium phosphate cement delivering zoledronate decreases bone turnover rate and restores bone architecture in ovariectomized rats.

    PubMed

    Wu, Chang-Chin; Wang, Chen-Chie; Lu, Dai-Hua; Hsu, Li-Ho; Yang, Kai-Chiang; Lin, Feng-Huei

    2012-06-01

    Patients sustaining bony fractures frequently require the application of bone graft substitutes to fill the bone defects. In the meantime, anti-osteoporosis drugs may be added in bone fillers to treat osteoporosis, especially in postmenopausal women and the elderly. The effects of zoledronate-impregnated calcium phosphate cement (ZLN/CPC) on ovariectomized (OVX) rats were evaluated. OVX rats were implanted with ZLN/CPC, containing 0.025 mg ZLN in the greater omentum. Afterward the clinical sign of toxicity was recorded for eight weeks. The rats were sacrificed and blood samples were collected for hematology and serum bone turnover markers analyses. The four limbs of the rats were harvested and micro-computer tomography (micro-CT) scanning and bone ash analyses were performed. No clinical toxicity was observed in the treated rats. Compared to the OVX rats, levels of bone resorption markers (fragments of C-telopeptides of type I collagen) and bone formation markers (alkaline phosphatase and osteocalcin) decreased significantly in the treated rats. Osteopontin, which mediates the anchoring of osteoclasts to the mineral matrix of bones, also decreased significantly. Micro-CT scanning and histologic examinations of the distal femoral metaphyses showed that the cancellous bone architectures were restored, with a concomitant decrease in bone porosity. The bone mineral content in the bone ashes also increased significantly. This study indicates that ZLN-impregnated CPC reduces bone turnover rate and restores bone architecture in OVX rats. CPC may be an appropriate carrier to deliver drugs to treat osteoporosis, and this approach may also reduce rates of post-dosing symptoms for intravenous ZLN delivery.

  13. Hyoid bone fusion and bone density across the lifespan: prediction of age and sex.

    PubMed

    Fisher, Ellie; Austin, Diane; Werner, Helen M; Chuang, Ying Ji; Bersu, Edward; Vorperian, Houri K

    2016-06-01

    The hyoid bone supports the important functions of swallowing and speech. At birth, the hyoid bone consists of a central body and pairs of right and left lesser and greater cornua. Fusion of the greater cornua with the body normally occurs in adulthood, but may not occur at all in some individuals. The aim of this study was to quantify hyoid bone fusion across the lifespan, as well as assess developmental changes in hyoid bone density. Using a computed tomography imaging studies database, 136 hyoid bones (66 male, 70 female, ages 1-to-94) were examined. Fusion was ranked on each side and hyoid bones were classified into one of four fusion categories based on their bilateral ranks: bilateral distant non-fusion, bilateral non-fusion, partial or unilateral fusion, and bilateral fusion. Three-dimensional hyoid bone models were created and used to calculate bone density in Hounsfield units. Results showed a wide range of variability in the timing and degree of hyoid bone fusion, with a trend for bilateral non-fusion to decrease after age 20. Hyoid bone density was significantly lower in adult female scans than adult male scans and decreased with age in adulthood. In sex and age estimation models, bone density was a significant predictor of sex. Both fusion category and bone density were significant predictors of age group for adult females. This study provides a developmental baseline for understanding hyoid bone fusion and bone density in typically developing individuals. Findings have implications for the disciplines of forensics, anatomy, speech pathology, and anthropology.

  14. Scanning Seismic Intrusion Detector

    NASA Technical Reports Server (NTRS)

    Lee, R. D.

    1982-01-01

    Scanning seismic intrusion detector employs array of automatically or manually scanned sensors to determine approximate location of intruder. Automatic-scanning feature enables one operator to tend system of many sensors. Typical sensors used with new system are moving-coil seismic pickups. Detector finds uses in industrial security systems.

  15. Multipurpose binocular scanning apparatus

    NASA Technical Reports Server (NTRS)

    Chamberlain, F. R.; Parker, G. L.

    1969-01-01

    Optical gimballing apparatus directs narrow fields of view throughout solid angle approaching 4 pi steradians. Image rotation produced by scanning can be eliminated or altered by gear trains directly linked to the scanning drive assembly. It provides the basis for a binocular scanning capability.

  16. Bone densitometry in infants

    SciTech Connect

    Barden, H.S.; Mazess, R.B.

    1988-07-01

    Bone mineral mass and density can be measured noninvasively by various absorptiometric procedures. Two methods, dual-photon absorptiometry (DPA) and quantitative computed tomography, have widespread application in adults but only limited use in children. One method, single-photon absorptiometry (SPA), has been used extensively in adults and children and has been modified for use in infants. The radius shaft has been used for most research on infants. However, the difficulty of using older SPA methods on this small bone (4 to 7 mm width) has led a few investigators to measure the shaft of the humerus. The typical precision of measurement in a newborn is about 5% with the use of computerized rectilinear scanners for the radius; older linear scanners have a precision error of 5% to 10% on the humerus. Linear scanners cannot measure precisely the radius in individual neonates. The SPA scans typically take about 5 minutes. The DPA technique using /sup 153/Gd has been modified for use on smaller animals (5 to 10 kg monkeys and dogs), but it has not been used on infants because DPA scans take 20 minutes. New methods using x-ray absorptiometry allow rapid (1 minute), precise (1%) measurements in the perinate. The need for a soft tissue bolus is eliminated, and both the axial and peripheral skeletons can be measured with dual-energy x-ray absorptiometry. Ultrasonic measurements do not yet offer adequate precision in the neonate, given the limited biologic range of values. 83 references.

  17. An electrostatic 3-phase linear stepper motor fabricated by vertical trench isolation technology

    NASA Astrophysics Data System (ADS)

    Sarajlic, Edin; Yamahata, Christophe; Cordero, Mauricio; Fujita, Hiroyuki

    2009-07-01

    We present the design, microfabrication and characterization of an electrostatic 3-phase linear stepper micromotor constructed with vertical trench isolation technology. This suitable technology was used to create a monolithic stepper motor with high-aspect-ratio poles and an integrated 3-phase electrical network in the bulk of a standard single-crystal silicon wafer. The shuttle of the stepper motor is suspended by a flexure to avoid any mechanical contact during operation, enhancing the precision, repeatability and reliability of the stepping motion. The prototype is capable of a maximum travel of +/-26 µm (52 µm) at an actuation voltage of 30 V and a step size of 1.4 µm during a half-stepping sequence. This work was presented in part at the 19th MicroMechanics Europe Workshop (MME), 28-30 September 2008, Aachen, Germany.

  18. Association between Bone Mass and Dental Hypomineralization.

    PubMed

    van der Tas, J T; Elfrink, M E C; Vucic, S; Heppe, D H M; Veerkamp, J S J; Jaddoe, V W V; Rivadeneira, F; Hofman, A; Moll, H A; Wolvius, E B

    2016-04-01

    The aim of this study was to examine the association between the bone mass (bone mineral content [BMC]) and hypomineralized second primary molars (HSPMs)/molar incisor hypomineralization (MIH) in 6-y-old children. This cross-sectional study was embedded in the Generation R Study, a population-based prospective cohort study, starting from fetal life until adulthood in Rotterdam, Netherlands. The European Academy of Pediatric Dentistry criteria were used to score the intraoral photographs on the presence or absence of HSPMs and MIH. Bone mass was measured with a dual-energy x-ray absorptiometry (DXA) scan. Intraoral photographs and DXA scans were available in 6,510 6-y-old children. Binary logistic regression models were used to study the association between the bone mass and HSPMs/MIH. In total, 5,586 children had their second primary molars assessed and a DXA scan made; 507 children were diagnosed with HSPM. Of 2,370 children with data on their permanent first molars, 203 were diagnosed with MIH. In the fully adjusted model, children with lower BMC (corrected for bone area) were more likely to have HSPMs (odds ratio, 1.13; 95% confidence interval, 1.02 to 1.26 per 1-standard deviation decrease). A lower BMC (corrected for bone area) was not associated with MIH (odds ratio, 1.02; 95% confidence interval, 0.87 to 1.20 per 1-standard deviation decrease). We observed a negative association between BMC (corrected for bone area) and HSPMs. No association was found between BMC (corrected for bone area) and MIH. Future research should focus on investigating the mechanism underlying the negative association between the bone mass and HSPMs. Our study, in a large population of 6-y-old children, adds the finding that BMC (corrected for bone size) is associated with HSPMs but not with MIH in childhood. PMID:26747420

  19. Pulmonary ventilation/perfusion scan

    MedlinePlus

    V/Q scan; Ventilation/perfusion scan; Lung ventilation/perfusion scan ... A pulmonary ventilation/perfusion scan is actually two tests. They may be done separately or together. During the perfusion scan, a health care ...

  20. Renal Cell Carcinoma Metastasized to Pagetic Bone

    PubMed Central

    Ramirez, Ashley; Liu, Bo; Rop, Baiywo; Edison, Michelle; Valente, Michael

    2016-01-01

    Paget’s disease of the bone, historically known as osteitis deformans, is an uncommon disease typically affecting individuals of European descent. Patients with Paget’s disease of the bone are at increased risk for primary bone neoplasms, particularly osteosarcoma. Many cases of metastatic disease to pagetic bone have been reported. However, renal cell carcinoma metastasized to pagetic bone is extremely rare. A 94-year-old male presented to the emergency department complaining of abdominal pain. A computed tomography scan of the abdomen demonstrated a large mass in the right kidney compatible with renal cell carcinoma. The patient was also noted to have Paget’s disease of the pelvic bones and sacrum. Within the pagetic bone of the sacrum, there was an enhancing mass compatible with renal cell carcinoma. A subsequent biopsy of the renal lesion confirmed renal cell carcinoma. Paget’s disease of the bone places the patient at an increased risk for bone neoplasms. The most commonly reported sites for malignant transformation are the femur, pelvis, and humerus. In cases of malignant transformation, osteosarcoma is the most common diagnosis. Breast, lung, and prostate carcinomas are the most common to metastasize to pagetic bone. Renal cell carcinoma associated with Paget’s disease of the bone is very rare, with only one prior reported case. Malignancy in Paget's disease of the bone is uncommon with metastatic disease to pagetic bone being extremely rare. We report a patient diagnosed with concomitant renal cell carcinoma and metastatic disease within Paget’s disease of the sacrum. Further research is needed to assess the true incidence of renal cell carcinoma associated with pagetic bone.

  1. Renal Cell Carcinoma Metastasized to Pagetic Bone.

    PubMed

    Ramirez, Ashley; Liu, Bo; Rop, Baiywo; Edison, Michelle; Valente, Michael; Burt, Jeremy

    2016-01-01

    Paget's disease of the bone, historically known as osteitis deformans, is an uncommon disease typically affecting individuals of European descent. Patients with Paget's disease of the bone are at increased risk for primary bone neoplasms, particularly osteosarcoma. Many cases of metastatic disease to pagetic bone have been reported. However, renal cell carcinoma metastasized to pagetic bone is extremely rare. A 94-year-old male presented to the emergency department complaining of abdominal pain. A computed tomography scan of the abdomen demonstrated a large mass in the right kidney compatible with renal cell carcinoma. The patient was also noted to have Paget's disease of the pelvic bones and sacrum. Within the pagetic bone of the sacrum, there was an enhancing mass compatible with renal cell carcinoma. A subsequent biopsy of the renal lesion confirmed renal cell carcinoma. Paget's disease of the bone places the patient at an increased risk for bone neoplasms. The most commonly reported sites for malignant transformation are the femur, pelvis, and humerus. In cases of malignant transformation, osteosarcoma is the most common diagnosis. Breast, lung, and prostate carcinomas are the most common to metastasize to pagetic bone. Renal cell carcinoma associated with Paget's disease of the bone is very rare, with only one prior reported case. Malignancy in Paget's disease of the bone is uncommon with metastatic disease to pagetic bone being extremely rare. We report a patient diagnosed with concomitant renal cell carcinoma and metastatic disease within Paget's disease of the sacrum. Further research is needed to assess the true incidence of renal cell carcinoma associated with pagetic bone.

  2. Renal Cell Carcinoma Metastasized to Pagetic Bone.

    PubMed

    Ramirez, Ashley; Liu, Bo; Rop, Baiywo; Edison, Michelle; Valente, Michael; Burt, Jeremy

    2016-01-01

    Paget's disease of the bone, historically known as osteitis deformans, is an uncommon disease typically affecting individuals of European descent. Patients with Paget's disease of the bone are at increased risk for primary bone neoplasms, particularly osteosarcoma. Many cases of metastatic disease to pagetic bone have been reported. However, renal cell carcinoma metastasized to pagetic bone is extremely rare. A 94-year-old male presented to the emergency department complaining of abdominal pain. A computed tomography scan of the abdomen demonstrated a large mass in the right kidney compatible with renal cell carcinoma. The patient was also noted to have Paget's disease of the pelvic bones and sacrum. Within the pagetic bone of the sacrum, there was an enhancing mass compatible with renal cell carcinoma. A subsequent biopsy of the renal lesion confirmed renal cell carcinoma. Paget's disease of the bone places the patient at an increased risk for bone neoplasms. The most commonly reported sites for malignant transformation are the femur, pelvis, and humerus. In cases of malignant transformation, osteosarcoma is the most common diagnosis. Breast, lung, and prostate carcinomas are the most common to metastasize to pagetic bone. Renal cell carcinoma associated with Paget's disease of the bone is very rare, with only one prior reported case. Malignancy in Paget's disease of the bone is uncommon with metastatic disease to pagetic bone being extremely rare. We report a patient diagnosed with concomitant renal cell carcinoma and metastatic disease within Paget's disease of the sacrum. Further research is needed to assess the true incidence of renal cell carcinoma associated with pagetic bone. PMID:27660736

  3. Renal Cell Carcinoma Metastasized to Pagetic Bone

    PubMed Central

    Ramirez, Ashley; Liu, Bo; Rop, Baiywo; Edison, Michelle; Valente, Michael

    2016-01-01

    Paget’s disease of the bone, historically known as osteitis deformans, is an uncommon disease typically affecting individuals of European descent. Patients with Paget’s disease of the bone are at increased risk for primary bone neoplasms, particularly osteosarcoma. Many cases of metastatic disease to pagetic bone have been reported. However, renal cell carcinoma metastasized to pagetic bone is extremely rare. A 94-year-old male presented to the emergency department complaining of abdominal pain. A computed tomography scan of the abdomen demonstrated a large mass in the right kidney compatible with renal cell carcinoma. The patient was also noted to have Paget’s disease of the pelvic bones and sacrum. Within the pagetic bone of the sacrum, there was an enhancing mass compatible with renal cell carcinoma. A subsequent biopsy of the renal lesion confirmed renal cell carcinoma. Paget’s disease of the bone places the patient at an increased risk for bone neoplasms. The most commonly reported sites for malignant transformation are the femur, pelvis, and humerus. In cases of malignant transformation, osteosarcoma is the most common diagnosis. Breast, lung, and prostate carcinomas are the most common to metastasize to pagetic bone. Renal cell carcinoma associated with Paget’s disease of the bone is very rare, with only one prior reported case. Malignancy in Paget's disease of the bone is uncommon with metastatic disease to pagetic bone being extremely rare. We report a patient diagnosed with concomitant renal cell carcinoma and metastatic disease within Paget’s disease of the sacrum. Further research is needed to assess the true incidence of renal cell carcinoma associated with pagetic bone. PMID:27660736

  4. [Bone transplant].

    PubMed

    San Julián, M; Valentí, A

    2006-01-01

    We describe the methodology of the Bone and Soft Tissue Bank, from extraction and storage until use. Since the year 1986, with the creation of the Bone Bank in the University Clinic of Navarra, more than 3,000 grafts have been used for very different types of surgery. Bone grafts can be classified into cortical and spongy; the former are principally used in surgery to save tumour patients, in large post-traumatic reconstructions and in replacement surgery where there are massive bone defects and a structural support is required. The spongy grafts are the most used due to their numerous indications; they are especially useful in filling cavities that require a significant quantity of graft when the autograft is insufficient, or as a complement. They are also of special help in treating fractures when there is bone loss and in the treatment of delays in consolidation and pseudoarthrosis in little vascularized and atrophic zones. They are also used in prosthetic surgery against the presence of cavity type defects. Allografts of soft tissues are specially recognised in multiple ligament injuries that require reconstructions. Nowadays, the most utilised are those employed in surgery of the anterior cruciate ligament although they can be used for filling any ligament or tendon defect. The principal difficulties of the cortical allografts are in the consolidation of the ends with the bone itself and in tumour surgery, given that these are patients immunodepressed by the treatment, the incidence of infection is increased with respect to spongy grafts and soft tissues, which is irrelevant. In short, the increasingly widespread use of allografts is an essential therapeutic weapon in orthopaedic surgery and traumatology. It must be used by expert hands.

  5. [Bone transplant].

    PubMed

    San Julián, M; Valentí, A

    2006-01-01

    We describe the methodology of the Bone and Soft Tissue Bank, from extraction and storage until use. Since the year 1986, with the creation of the Bone Bank in the University Clinic of Navarra, more than 3,000 grafts have been used for very different types of surgery. Bone grafts can be classified into cortical and spongy; the former are principally used in surgery to save tumour patients, in large post-traumatic reconstructions and in replacement surgery where there are massive bone defects and a structural support is required. The spongy grafts are the most used due to their numerous indications; they are especially useful in filling cavities that require a significant quantity of graft when the autograft is insufficient, or as a complement. They are also of special help in treating fractures when there is bone loss and in the treatment of delays in consolidation and pseudoarthrosis in little vascularized and atrophic zones. They are also used in prosthetic surgery against the presence of cavity type defects. Allografts of soft tissues are specially recognised in multiple ligament injuries that require reconstructions. Nowadays, the most utilised are those employed in surgery of the anterior cruciate ligament although they can be used for filling any ligament or tendon defect. The principal difficulties of the cortical allografts are in the consolidation of the ends with the bone itself and in tumour surgery, given that these are patients immunodepressed by the treatment, the incidence of infection is increased with respect to spongy grafts and soft tissues, which is irrelevant. In short, the increasingly widespread use of allografts is an essential therapeutic weapon in orthopaedic surgery and traumatology. It must be used by expert hands. PMID:16998521

  6. Bone Marrow Transplantation

    MedlinePlus

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. ... platelets, which help the blood to clot. A bone marrow transplant is a procedure that replaces a person's ...

  7. Genetics of Bone Density

    MedlinePlus

    ... study linked 32 novel genetic regions to bone mineral density. The findings may help researchers understand why ... or treating osteoporosis. Bones are made of a mineral and protein scaffold filled with bone cells. Bone ...

  8. Bone biopsy (image)

    MedlinePlus

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  9. Line-scanning, stage scanning confocal microscope

    NASA Astrophysics Data System (ADS)

    Carucci, John A.; Stevenson, Mary; Gareau, Daniel

    2016-03-01

    We created a line-scanning, stage scanning confocal microscope as part of a new procedure: video assisted micrographic surgery (VAMS). The need for rapid pathological assessment of the tissue on the surface of skin excisions very large since there are 3.5 million new skin cancers diagnosed annually in the United States. The new design presented here is a confocal microscope without any scanning optics. Instead, a line is focused in space and the sample, which is flattened, is physically translated such that the line scans across its face in a direction perpendicular to the line its self. The line is 6mm long and the stage is capable of scanning 50 mm, hence the field of view is quite large. The theoretical diffraction-limited resolution is 0.7um lateral and 3.7um axial. However, in this preliminary report, we present initial results that are a factor of 5-7 poorer in resolution. The results are encouraging because they demonstrate that the linear array detector measures sufficient signal from fluorescently labeled tissue and also demonstrate the large field of view achievable with VAMS.

  10. BONE BANKS

    PubMed Central

    de Alencar, Paulo Gilberto Cimbalista; Vieira, Inácio Facó Ventura

    2015-01-01

    Bone banks are necessary for providing biological material for a series of orthopedic procedures. The growing need for musculoskeletal tissues for transplantation has been due to the development of new surgical techniques, and this has led to a situation in which a variety of hospital services have been willing to have their own source of tissue for transplantation. To increase the safety of transplanted tissues, standards for bone bank operation have been imposed by the government, which has limited the number of authorized institutions. The good performance in a bone bank depends on strict control over all stages, including: formation of well-trained harvesting teams; donor selection; conducting various tests on the tissues obtained; and strict control over the processing techniques used. Combination of these factors enables greater scope of use and numbers of recipient patients, while the incidence of tissue contamination becomes statistically insignificant, and there is traceability between donors and recipients. This paper describes technical considerations relating to how a bone bank functions, the use of grafts and orthopedic applications, the ethical issues and the main obstacles encountered. PMID:27026958

  11. Digital radiographic localization for CT scanning of the larynx

    SciTech Connect

    Silverman, P.M.; Korobkin, M.; Rauch, R.F.

    1983-12-01

    Computed tomography (CT) of the larynx is the preferred method for staging laryngeal carcinoma and assessing the extent of injury from trauma. The standard method of examination consists of 5 mm contiguous scans throughout the larynx in quiet respiration. Scans are performed with the patient supine with the neck slightly extended allowing the long axis of the larynx to be perpendicular to the scanning plane. A complete examination requires scanning from the supraglottic region (level of hyoid bone) to the subglottic region (level of cricoid cartlage). In the authors' experience when this method is used, multiple scans are performed cephalad to the level of interest because no upper limit of the examination is established before transaxial scans are done. We have used the lateral digital radiograph of the neck to identify specific landmarks so that the upper and lower limets of the examination can be established before scanning.

  12. Short- and long-term effects of vertebroplastic bone cement on cancellous bone.

    PubMed

    Quan, Renfu; Ni, Yueming; Zhang, Liang; Xu, Jinwei; Zheng, Xuan; Yang, Disheng

    2014-07-01

    Vertebroplasty using poly(methyl methacrylate) (PMMA) bone cement is the most common method to treat osteoporotic vertebral fractures. However, several questions of interest remain to be clarified, including how does PMMA affect the cement-bone interface area and surrounding bone tissue, can damaged bone tissues be repaired, how will PMMA change the bone interface over the long-term, and what happens to PMMA itself? The purpose of this study is to investigate these concerns and provide a basis for clinical evaluation. We made bone defects in the lumbar vertebrae of New Zealand rabbits as a model of osteoporosis and injected them with bone cement. A mechanical testing machine was used to perform axial compression, three-point bending, and twisting resistance tests to observe and investigate the short- and long-term biomechanical properties of PMMA after implantation. Optical, fluorescence, scanning electron microscopy, and nanoindentation were used to observe the changes in the interface microstructure. PMMA can rapidly establish the strong support with stable function in the near future. Biomechanical experiments showed that biomechanical property of bone cement group was significantly higher than those in the other two groups (P<0.05) biomechanical property of bone cement group may decline with the time, but it's still better than that of OP in the control group (P<0.05). Histomorphological observation result shows that under osteoporosis state the bone grows slower, also bone's rebuilding time extended. And in the later period, main bone's continuous osteoporosis has some impact on the interface. Nano-indentation testing shows that the young modulus and stiffness of the interface among bone, material and interface were significantly differences (P<0.05). Bone cement had gave the best nano indentation hardness, then was interface and bone tissue. PMMA bone cement was able to quickly support and stabilize the defect in the short term, and bone growth restarted at

  13. Sinus MRI scan

    MedlinePlus

    ... that may have been exposed to small metal fragments should receive a skull x-ray. This is ... due to: Cancer or tumor Infection in the bones of the sinuses (osteomyelitis) Infection of the tissues ...

  14. Comparison of single- and dual-photon absorptiometry in postmenopausal bone mineral loss

    SciTech Connect

    Nilas, L.; Borg, J.; Gotfredsen, A.; Christiansen, C.

    1985-11-01

    The authors describe a single photon absorptiometric (SPA) technique, which enables differential estimation of the rates of loss from trabecular and cortical bone. Ten scans are obtained in the forearm: six in an area with about 7% trabecular bone and four scans in the adjacent distal area with a trabecular bone content of 25%. By comparing bone masses of these two sites in 19 postmenopausal and 53 premenopausal women, the postmenopausal trabecular bone loss was estimated to be approximately seven times greater than cortical loss within the first years of cessation of regular vaginal bleeding. On a group basis the bone loss at the distal forearm scan site (by SPA) corresponded closely to the spinal bone loss (by dual-photon absorptiometry). The reproducibility of the two scan sites in the forearm was 1-1.5% (CV%), which makes the method suitable for longitudinal studies. Corrections for variations in fatty tissue covering can be made without deterioration of the reproducibility.

  15. Dynamic CT scanning of spinal column trauma

    SciTech Connect

    Brown, B.M.; Brant-Zawadzki, M.; Cann, C.E.

    1982-12-01

    Dynamic sequential computed tomographic scanning with automatic table incrementation uses low milliampere-second technique to eliminate tube cooling delays between scanning slices and, thus, markedly shortens examination times. A total of 25 patients with spinal column trauma involving 28 levels were studied with dynamic scans and retrospectively reviewed. Dynamic studies were considerably faster than conventional spine examinations and yielded reliable diagnosis. Bone disruption and subluxation was accurately evaluated, and the use of intrathecal metrizamide in low doses allowed direct visualization of spinal cord or radicular compromise. Multiplanar image reformation was aided by the dynamic incrementation technique, since motion between slices (and the resulting misregistration artifact on image reformation) was minimized. A phantom was devised to test spatial resolution of computed tomography for objects 1-3 mm in size and disclosed minimal differences for dynamic and conventional computed tomographic techniques in resolving medium-to-high-contrast objects.

  16. Assumption or Fact? Line-to-Neutral Voltage Expression in an Unbalanced 3-Phase Circuit during Inverter Switching

    ERIC Educational Resources Information Center

    Masrur, M. A.

    2009-01-01

    This paper discusses the situation in a 3-phase motor or any other 3-phase system operating under unbalanced operating conditions caused by an open fault in an inverter switch. A dc voltage source is assumed as the input to the inverter, and under faulty conditions of the inverter switch, the actual voltage applied between the line to neutral…

  17. Negative radionuclide scan in osteoid osteoma. A case report

    SciTech Connect

    Fehring, T.K.; Green, N.E.

    1984-05-01

    Advances in radionuclide imaging have facilitated the accurate diagnosis and surgical excision of osteoid osteoma. While radionuclide imaging has been inconsistent in the diagnosis of certain problems, its accuracy in the diagnosis of osteoid osteoma has been frequently stressed. To date, no case of a negative bone scan in the presence of a histologically proven osteoid osteoma has been reported. The present case report emphasizes that a negative bone scan does not preclude the diagnosis of osteoid osteoma. Clinical suspicion remains the most sensitive indicator of this lesion.

  18. Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

    NASA Technical Reports Server (NTRS)

    Spector, E.; LeBlanc, A.; Shackelford, L.

    1995-01-01

    This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between

  19. [Osteoplastic effectiveness of mineralized bone matrix].

    PubMed

    2013-01-01

    In the experiment conducted on 50 Wistar rats, the peculiarities of the reparative osteogenesis were studied using scanning electron microscopy, x-ray electron-probe microanalysis and histological techniques. Granulated mineralized bone matrix (MBM) obtained without thermal and demineralizing treatment, was implanted into the tibial defect. MBM was found to possess marked osteoinductive and osteoconductive properties. It induced a prolonged activation of reparative osteogenesis after the implantation, as well as deep bone tissue ingrowth into the implant, acceleration of organotypic remodeling of regenerated bone, intense angiogenesis and early restoration of the damaged

  20. [Osteoplastic effectiveness of mineralized bone matrix].

    PubMed

    2013-01-01

    In the experiment conducted on 50 Wistar rats, the peculiarities of the reparative osteogenesis were studied using scanning electron microscopy, x-ray electron-probe microanalysis and histological techniques. Granulated mineralized bone matrix (MBM) obtained without thermal and demineralizing treatment, was implanted into the tibial defect. MBM was found to possess marked osteoinductive and osteoconductive properties. It induced a prolonged activation of reparative osteogenesis after the implantation, as well as deep bone tissue ingrowth into the implant, acceleration of organotypic remodeling of regenerated bone, intense angiogenesis and early restoration of the damaged PMID:23805618

  1. Bone Densitometry: Current Status and Future Perspective.

    PubMed

    Crabtree, Nicola; Ward, Kate

    2015-01-01

    In this chapter, we discuss the concept of what determines bone strength and fracture risk and how this can be quantified using current technologies. We describe bone densitometry measurement techniques that are currently available and consider the strengths and limitations of each technique, with particular emphasis on paediatric scanning. Magnetic resonance imaging is reviewed, as it is one of the newer technologies applied to assessment of the growing skeleton. The role of dual-energy X-ray absorptiometry and quantitative computed tomography in the clinical assessment of bone health in children is considered, and their current diagnostic application is reviewed. PMID:26138836

  2. A quantification strategy for missing bone mass in case of osteolytic bone lesions

    SciTech Connect

    Fränzle, Andrea Giske, Kristina; Bretschi, Maren; Bäuerle, Tobias; Hillengass, Jens; Bendl, Rolf

    2013-12-15

    Purpose: Most of the patients who died of breast cancer have developed bone metastases. To understand the pathogenesis of bone metastases and to analyze treatment response of different bone remodeling therapies, preclinical animal models are examined. In breast cancer, bone metastases are often bone destructive. To assess treatment response of bone remodeling therapies, the volumes of these lesions have to be determined during the therapy process. The manual delineation of missing structures, especially if large parts are missing, is very time-consuming and not reproducible. Reproducibility is highly important to have comparable results during the therapy process. Therefore, a computerized approach is needed. Also for the preclinical research, a reproducible measurement of the lesions is essential. Here, the authors present an automated segmentation method for the measurement of missing bone mass in a preclinical rat model with bone metastases in the hind leg bones based on 3D CT scans. Methods: The affected bone structure is compared to a healthy model. Since in this preclinical rat trial the metastasis only occurs on the right hind legs, which is assured by using vessel clips, the authors use the left body side as a healthy model. The left femur is segmented with a statistical shape model which is initialised using the automatically segmented medullary cavity. The left tibia and fibula are segmented using volume growing starting at the tibia medullary cavity and stopping at the femur boundary. Masked images of both segmentations are mirrored along the median plane and transferred manually to the position of the affected bone by rigid registration. Affected bone and healthy model are compared based on their gray values. If the gray value of a voxel indicates bone mass in the healthy model and no bone in the affected bone, this voxel is considered to be osteolytic. Results: The lesion segmentations complete the missing bone structures in a reasonable way. The mean

  3. Bone image segmentation.

    PubMed

    Liu, Z Q; Liew, H L; Clement, J G; Thomas, C D

    1999-05-01

    Characteristics of microscopic structures in bone cross sections carry essential clues in age determination in forensic science and in the study of age-related bone developments and bone diseases. Analysis of bone cross sections represents a major area of research in bone biology. However, traditional approaches in bone biology have relied primarily on manual processes with very limited number of bone samples. As a consequence, it is difficult to reach reliable and consistent conclusions. In this paper we present an image processing system that uses microstructural and relational knowledge present in the bone cross section for bone image segmentation. This system automates the bone image analysis process and is able to produce reliable results based on quantitative measurements from a large number of bone images. As a result, using large databases of bone images to study the correlation between bone structural features and age-related bone developments becomes feasible.

  4. New bone formation by murine osteoprogenitor cells cultured on corticocancellous allograft bone.

    PubMed

    Nelson, Ehren R; Huang, Zhinong; Ma, Ting; Lindsey, Derek; Jacobs, Christopher; Smith, Robert L; Goodman, Stuart B

    2008-12-01

    The gold standard for bone grafting in orthopedics is autograft, however autograft has a limited supply and is associated with significant morbidity at the harvest site. One alternative, allograft bone, provides an osteoconductive scaffold, is in less limited supply, and it does not require a harvest from the patient. However, allograft lacks both osteogenic cells and osteoinductive proteins that make autograft bone so advantageous. This study provides a model to investigate strategies for augmentation of corticocancellous allograft bone discs with bone marrow-derived osteoprogenitor cells (OPCs) plus exogenous growth factors in vitro. In this model, allograft bone discs were created by cutting 1-mm thick slices from the distal femur and proximal tibia of euthanized mice. The allografts were sterilized and scanned by micro-computed tomography (microCT) to provide the pre-culture graft volume and trabecular characteristics. The discs were then seeded with OPCs harvested from murine bone marrow. The seeded grafts were placed in organ culture until harvest, after which they were re-scanned by microCT and the data compared to the corresponding pre-culture data. In addition, bone morphogenetic protein-7 (BMP-7, also know as osteogenic protein-1 or OP-1), basic fibroblast growth factor (bFGF), and OP-1 combined with bFGF were added on a daily basis to the cultures. After final microCT scanning, all grafts were sectioned and evaluated histologically after hematoxylin and eosin (H&E) staining. microCT scans of cultured allografts with cells at 3, 5, and 9 weeks showed a time-dependent, statistically significant increase in bone volume. The trabecular thickness (Tb.Th.) of grafts, from both groups that were augmented with OP-1, showed a statistically significant increase in trabecular thickness of allografts with OPCs. These data suggest that bone marrow-derived OPCs adhere to, and produce, new bone on corticocancellous allograft in vitro. When exogenous OP-1 is added to

  5. Detection of musculoskeletal infection with the indium-III leukocyte scan

    SciTech Connect

    Prchal, C.L.; Kahen, H.L.; Blend, M.J.; Barmada, R.

    1987-09-01

    Indium-111-labeled leukocyte scans were performed on 39 patients with suspected musculoskeletal infections to assess the usefulness of this study in detecting bone and joint infections. Results of these scans, as well as results of technetium-99m bone scans, were correlated with the patients' final diagnoses. The indium scan had an overall sensitivity of 77%, a specificity of 69%, and an accuracy of 72%. In 10 patients with a duration of symptoms of six weeks or less, the sensitivity was 100% and the specificity was 75%. In 29 patients with symptoms of greater than six weeks, the sensitivity and specificity were lower at 50% and 71% respectively. Technetium-99m bone scans were performed on 23 patients; sensitivity for infection was 100% while specificity was 60%. Our results suggest that the indium-111 leukocyte scan is a useful adjunct in the diagnosis of acute musculoskeletal infections, but may be inconclusive in chronic infections.

  6. Spectroscopic and Structural Investigations of alpha-beta-, and gamma-AIH3 Phases

    SciTech Connect

    Manciu, F.S.; Graetz, J.; Reza, L.; Durrer, W.G.; Bronson, A.; Lacina, D.

    2010-07-01

    With its reputation as a high-energy density fuel, aluminum hydride (AlH{sub 3}) has received renewed attention as a material that is particularly suitable, not only for hydrogen storage but also for rocket propulsion. While the various phases of AlH{sub 3} have been investigated theoretically, there is a shortage of experimental studies corroborating the theoretical findings. In response to this, we present here an investigation of these compounds based primarily on two research areas in which there is the greatest scarcity of information in the literature, namely Raman and infrared (IR) absorption analysis. To the authors knowledge, this is the first report of experimental far-IR absorption results on these compounds. Two different samples prepared by broadly similar ethereal reactions of AlCl{sub 3} with LiAlH{sub 4} were analyzed. Both Raman and IR absorption measurements indicate that one sample is purely {gamma}-AlH{sub 3} and that the other is a mixture of {alpha}-, {beta}-, and {gamma}-AlH{sub 3} phases. X-ray diffraction confirms the spectroscopic findings, most notably for the {beta}-AlH{sub 3} phase, for which optical spectroscopic data are reported here for the first time.

  7. Getting a CAT Scan

    MedlinePlus

    ... Here's Help White House Lunch Recipes Getting a CAT Scan (Video) KidsHealth > For Kids > Getting a CAT Scan (Video) A A A en español Obtención de una tomografía computada (video) CAT stands for "computerized axial tomography." Translated, that means ...

  8. Optical Scanning Applications.

    ERIC Educational Resources Information Center

    Wagner, Hans

    The successful use of optical scanning at the University of the Pacific (UOP) indicates that such techniques can simplify a number of administrative data processing tasks. Optical scanning is regularly used at UOP to assist with data processing in the areas of admissions, registration and grade reporting and also has applications for other tasks…

  9. Multiline radar scan

    NASA Technical Reports Server (NTRS)

    Levinson, S.

    1977-01-01

    Scanning scheme is more efficient than conventional scanning. Originally designed for optical radar in space vehicles, scheme may also find uses in site-surveillance security systems and in other industrial applications. It should be particularly useful when system must run on battery energy, as would be case in power outages.

  10. Frontal bone fractures.

    PubMed

    Marinheiro, Bruno Henrique; de Medeiros, Eduardo Henrique Pantosso; Sverzut, Cássio Edvard; Trivellato, Alexandre Elias

    2014-11-01

    The aim of this retrospective study was to evaluate the epidemiology, treatment, and complications of frontal bone fractures associated, or not, with other facial fractures. This evaluation also sought to minimize the influence of the surgeon's skills and the preference for any rigid internal fixation system. The files from 3758 patients who attended the Oral and Maxillofacial Surgery Department of the School of Dentistry of Ribeirao Preto, University of Sao Paulo, from March 2004 to November 2011 and presented with facial trauma were scanned, and 52 files were chosen for the review. Eleven (21.15%) of these patients had pure fractures of the frontal bone, and trauma incidence was more prevalent in men (92.3%), whites (61.53%), and adults (50%). Despite the use of helmets at the moment of the trauma, motorcycle crashes were the most common etiological factor (32.69%). Fracture of the anterior wall of the frontal sinus with displacement was the main injury observed (54.9%), and the most common treatment was internal fixation with a plate and screws (45.09%). Postoperative complications were observed in 35.29% of the cases. The therapy applied was effective in handling this type of fracture, and the success rate was comparable to that reported in other published studies. PMID:25377971

  11. Virtual slit scanning microscopy.

    PubMed

    Fiolka, Reto; Stemmer, Andreas; Belyaev, Yury

    2007-12-01

    We present a novel slit scanning confocal microscope with a CCD camera image sensor and a virtual slit aperture for descanning that can be adjusted during post-processing. A very efficient data structure and mathematical criteria for aligning the virtual aperture guarantee the ease of use. We further introduce a method to reduce the anisotropic lateral resolution of slit scanning microscopes. System performance is evaluated against a spinning disk confocal microscope on identical specimens. The virtual slit scanning microscope works as the spinning disk type and outperforms on thick specimens. PMID:17891411

  12. NOTE: An anatomically shaped lower body model for CT scanning of cadaver femurs

    NASA Astrophysics Data System (ADS)

    Tanck, Esther; Deenen, J. C. W.; Huisman, Henk Jan; Kooloos, Jan G.; Huizenga, Henk; Verdonschot, Nico

    2010-01-01

    Bone specific, CT-based finite element (FE) analyses have great potential to accurately predict the fracture risk of deteriorated bones. However, it has been shown that differences exist between FE-models of femora scanned in a water basin or scanned in situ within the human body, as caused by differences in measured bone mineral densities (BMD). In this study we hypothesized that these differences can be reduced by re-creating the patient CT-conditions by using an anatomically shaped physical model of the lower body. BMD distributions were obtained from four different femora that were scanned under three conditions: (1) in situ within the cadaver body, (2) in a water basin and (3) in the body model. The BMD of the three scanning protocols were compared at two locations: proximally, in the trabecular bone of the femoral head, and in the cortical bone of the femoral shaft. Proximally, no significant differences in BMD were found between the in situ scans and the scans in the body model, whereas the densities from the water basin scans were on average 10.8% lower than in situ. In the femoral shaft the differences between the three scanning protocols were insignificant. In conclusion, the body model better approached the in situ situation than a water basin. Future studies can use this body model to mimic patient situations and to develop protocols to improve the performance of the FE-models in actual patients.

  13. Stabilization of ZnMnO3 Phase from Sol-gel Synthesized Nitrate Precursors

    SciTech Connect

    Saraf, Laxmikant V.; Nachimuthu, Ponnusamy; Engelhard, Mark H.; Baer, Donald R.

    2010-02-01

    The stabilization and analysis of pure ZnMnO3 spinel phase may help to understand the solubility limits of Mn in ZnO in wurtzite and spinel cubic structures. In this report, synthesis and characterization of stable ZnMnO3 phase is discussed which is extracted from sol-gel synthesis of zinc and manganese nitrate precursors. The reflections at higher diffraction angles for this known cubic system with space group Fd3m were calculated with the help of JADE 8.0 program. High resolution X-ray photoelectron spectroscopy measurements of Mn3p position of ZnMnO3 compared with ZnMn2O4 showed a higher binding energy shift ~0.85 eV indicating Mn4+ valence state in ZnMnO3.

  14. Cost-Optimal Design of a 3-Phase Core Type Transformer by Gradient Search Technique

    NASA Astrophysics Data System (ADS)

    Basak, R.; Das, A.; Sensarma, A. K.; Sanyal, A. N.

    2014-04-01

    3-phase core type transformers are extensively used as power and distribution transformers in power system and their cost is a sizable proportion of the total system cost. Therefore they should be designed cost-optimally. The design methodology for reaching cost-optimality has been discussed in details by authors like Ramamoorty. It has also been discussed in brief in some of the text-books of electrical design. The paper gives a method for optimizing design, in presence of constraints specified by the customer and the regulatory authorities, through gradient search technique. The starting point has been chosen within the allowable parameter space the steepest decent path has been followed for convergence. The step length has been judiciously chosen and the program has been maneuvered to avoid local minimal points. The method appears to be best as its convergence is quickest amongst different optimizing techniques.

  15. Bone lesion biopsy

    MedlinePlus

    Benign (noncancerous) bone tumors include: Bone cyst Fibroma Osteoblastoma Osteoid osteoma Cancerous tumors include: Ewing sarcoma Multiple myeloma Osteosarcoma Other types of cancer that may have spread to the bone Abnormal ...

  16. Smoking and Bone Health

    MedlinePlus

    ... direct relationship between tobacco use and decreased bone density. Analyzing the impact of cigarette smoking on bone ... hard to determine whether a decrease in bone density is due to smoking itself or to other ...

  17. Facts about Broken Bones

    MedlinePlus

    ... las fracturas de huesos Your bones are tough stuff — but even tough stuff can break. Like a wooden pencil, bones will ... that? Get a lot of physical activity, especially stuff like jumping and running. Feed your bones the ...

  18. Bone marrow aspiration

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003658.htm Bone marrow aspiration To use the sharing features on this page, please enable JavaScript. Bone marrow is the soft tissue inside bones that helps ...

  19. The Scanning Optical Microscope.

    ERIC Educational Resources Information Center

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  20. Leg MRI scan

    MedlinePlus

    ... resonance imaging) scan of the leg uses strong magnets to create pictures of the leg. This may ... in your eyes) Because the MRI contains strong magnets, metal objects are not allowed into the room ...

  1. Slow Scan Telemedicine

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

  2. Pediatric CT Scans

    Cancer.gov

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  3. Fiber-Scanned Microdisplays

    NASA Technical Reports Server (NTRS)

    Crossman-Bosworth, Janet; Seibel, Eric

    2010-01-01

    Helmet- and head-mounted display systems, denoted fiber-scanned microdisplays, have been proposed to provide information in an "augmented reality" format (meaning that the information would be optically overlaid on the user's field of view).

  4. Brain PET scan

    MedlinePlus

    ... tests, such as magnetic resonance imaging ( MRI ) and computed tomography ( CT ) scans only reveal the structure of the ... a PET/CT. Alternative Names ... PT, Rijntjes M, Weiller C. Neuroimaging: Functional neuroimaging. In: Daroff RB, Fenichel GM, Jankovic ...

  5. The conical scan radiometer

    NASA Astrophysics Data System (ADS)

    Prosch, T.; Hennings, D.

    1982-07-01

    A satellite-borne conical scan radiometer (CSR) is proposed, offering multiangular and multispectral measurements of Earth radiation fields, including the total radiances, which are not available from conventional radiometers. Advantages of the CSR for meteorological studies are discussed. In comparison to conventional cross track scanning instruments, the CSR is unique with respect to the selected picture element size which is kept constant by means of a specially shaped detector matrix at all scan angles. The conical scan mode offers the chance to improve angular sampling. Angular sampling gaps of previous satellite-borne radiometers can be interpolated and complemented by CSR data. Radiances are measured through 10 radiometric channels which are selected to study cloudiness, water vapor, ozone, surface albedo, ground and mean stratospheric temperature, and aerosols.

  6. Scanning Mueller polarimetric microscopy.

    PubMed

    Le Gratiet, Aymeric; Dubreuil, Matthieu; Rivet, Sylvain; Le Grand, Yann

    2016-09-15

    A full Mueller polarimeter was implemented on a commercial laser-scanning microscope. The new polarimetric microscope is based on high-speed polarization modulation by spectral coding using a wavelength-swept laser as a source. Calibration as well as estimation of the measurement errors of the device are reported. The acquisition of Mueller images at the speed of a scanning microscope is demonstrated for the first time. Mueller images of mineral and biological samples illustrate this new polarimetric microscopy. PMID:27628391

  7. Wide scanning spherical antenna

    NASA Technical Reports Server (NTRS)

    Shen, Bing (Inventor); Stutzman, Warren L. (Inventor)

    1995-01-01

    A novel method for calculating the surface shapes for subreflectors in a suboptic assembly of a tri-reflector spherical antenna system is introduced, modeled from a generalization of Galindo-Israel's method of solving partial differential equations to correct for spherical aberration and provide uniform feed to aperture mapping. In a first embodiment, the suboptic assembly moves as a single unit to achieve scan while the main reflector remains stationary. A feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan thereby eliminating the need to oversize the main spherical reflector. In an alternate embodiment, both the main spherical reflector and the suboptic assembly are fixed. A flat mirror is used to create a virtual image of the suboptic assembly. Scan is achieved by rotating the mirror about the spherical center of the main reflector. The feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan.

  8. Experiment M-6: Bone Demineralization

    NASA Technical Reports Server (NTRS)

    Mack, Pauline B.; Vose, George; Vogt, Fred B.; LaChance, Paul A.

    1966-01-01

    Densitometric evaluations of serial radiographs of "normal" subjects have often shown rather frequent changes in bone mass within relatively short periods of time. For this reason it was decided to make two pre-flight and two post flight radiographs of the Gemini V backup crew. In comparing the changes observed preflight and post flight as the conventional os calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. In comparing the changes observed preflight and postflight as the conventional o calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. This is in contract to the 15.1 and 8.9 percent losses observed in the prime crew. It has long been known that the skeletal system experiences a general loss of mineral under immobilization or extended bed rest. However, in both Gemini IV and Gemini V studies, bone mass losses were greater in both the os calcis and phalanx than were shown by the TWU bed-rest subjects during the same period of time. Although the bone mass losses in the 8-day Gemini V flight were generally greater than in the 4-day Gemini IV flight, the information to date is still insufficient to conclude that the losses tend to progress linearly with time, or whether a form of physiological adaptation may occur in longer space flights.

  9. Bone marrow osteoma of the tibia: A case report

    PubMed Central

    ZHOU, BEN-GEN; LIU, MEI-YUAN; LV, LI-CHUN; XIA, HONG

    2014-01-01

    In this study, an unusual case of osteoma is presented, whereby a bone marrow osteoma was identified in the tibia. No previous cases of bone marrow osteoma have been reported. In this case, an eight-year-old male presented with discontinuous discomfort in the right distal calf for six months. Radiological examination and computed tomography revealed a radiopaque lesion within the affected bone. A technetium-99m bone scan revealed focally increased uptake in the same region. Together, these observations prior to surgery indicated that the patient may suffer from bone disease. Subsequently, a surgical excision was performed and the biopsy specimen was identified as bone marrow osteoma. Following surgery, the symptoms were eradicated and the prognosis was positive during the 24-month follow-up period. Bone marrow osteoma should be considered when a patient suffers from discontinuous and unexplained limb discomfort. PMID:25364463

  10. Atlas of computerized blood flow analysis in bone disease.

    PubMed

    Gandsman, E J; Deutsch, S D; Tyson, I B

    1983-11-01

    The role of computerized blood flow analysis in routine bone scanning is reviewed. Cases illustrating the technique include proven diagnoses of toxic synovitis, Legg-Perthes disease, arthritis, avascular necrosis of the hip, fractures, benign and malignant tumors, Paget's disease, cellulitis, osteomyelitis, and shin splints. Several examples also show the use of the technique in monitoring treatment. The use of quantitative data from the blood flow, bone uptake phase, and static images suggests specific diagnostic patterns for each of the diseases presented in this atlas. Thus, this technique enables increased accuracy in the interpretation of the radionuclide bone scan.

  11. Bone marrow transplant - discharge

    MedlinePlus

    Transplant - bone marrow - discharge; Stem cell transplant - discharge; Hematopoietic stem cell transplant - discharge; Reduced intensity; Non-myeloablative transplant - discharge; Mini transplant - discharge; Allogenic bone marrow transplant - ...

  12. Bone and bone marrow involvement in sarcoidosis.

    PubMed

    Yachoui, Ralph; Parker, Brian J; Nguyen, Thanhcuong T

    2015-11-01

    Bone and bone marrow involvement in sarcoidosis have been infrequently reported. We aimed to describe the clinical features, radiological descriptions, pathological examinations, and outcomes of three patients with osseous sarcoidosis and one patient with bone marrow sarcoidosis seen at our institution. Our case series included fluorodeoxyglucose positron emission tomography descriptions in assessing the whole-body extent of sarcoidosis. In the era of advanced imaging, large bone and axial skeleton sarcoidosis lesions are more common than previously reported.

  13. Splenic concentration of bone imaging agents in functional asplenia

    SciTech Connect

    Dhekne, R.D.

    1981-07-01

    Three cases of sickle cell disease associated with functional asplenia are described. The spleen was not visualized on routine Tc-99m-sulfur colloid scan. The bone scan performed with Tc-99m-phosphate compounds revealed abnormal splenic activity in all three cases. The previous case reports and the literature on this subject are reviewed.

  14. Serum bone gla protein (BGP) and other markers of bone mineral metabolism in postmenopausal osteoporosis.

    PubMed

    Ismail, F; Epstein, S; Pacifici, R; Droke, D; Thomas, S B; Avioli, L V

    1986-10-01

    Bone gla protein, the vitamin K-dependent protein synthesized by osteoblasts and measured in blood by radioimmunoassay, has been used as an index of the rate of bone turnover. The relationship of bone gla protein with other markers of bone mineral metabolism was determined in 31 untreated postmenopausal women with the osteoporotic syndrome. In addition to serum osteocalcin (BGP) we measured parathyroid hormone (PTH) (carboxyl and mid-molecule fragments), 25(OH)D, alkaline phosphatase, estradiol (E2), estrone (E1), dietary calcium intake, 24 hour urinary calcium excretion, and bone mineral density by CT scan of the lumbar vertebrae. Significant osteopenia was present on CT in untreated postmenopausal osteoporotic women (bone density in 18 out of 31 was below the critical value of 60 mg/cm3). Serum BGP correlated positively with CT scan (r + 0.647, P less than 0.001). CT and age were negatively correlated (r - 0.661, P less than 0.001) while CT and E2 showed a positive correlation (r + 0.554, P less than 0.01). Unexpectedly, BGP and age revealed a significant negative correlation (r - 0.421, P less than 0.05). These findings suggest a state of low bone turnover in this group with untreated postmenopausal osteoporosis.

  15. [Laser scanning in ophthalmology].

    PubMed

    Jean, B; Frohn, A; Thiel, H J

    1990-01-01

    The current state of the art for the major laser scanning methods, laser scanning ophthalmoscopy (LSO) and laser tomographic scanning (LTS) is discussed and the function principles are described. Experience with a prototype of each instrument from Rodenstock (LSO) and Heidelberg Instruments (LTS) is reported. LSO imaging of the cornea, vitreous, retina, and optic disc, as well as on-line processing is demonstrated with examples (nerve fibre colour coding and histograms). Measurement of the cornea, optic disc and retinal topography with LTS is also demonstrated with examples. An example of polarization optical imaging of the cornea's assumed interferometric "tension patterns" is shown. The current status and future possibilities of laser scanning, its expanded diagnostic potential with microperimetry, IR scanning angiography and polarization optic imaging and measurement (eg. nerve fibre thickness) is discussed extensively. The safety aspects of laser light exposure of the macula are also mentioned. Laser scanners as imaging and measuring sensors of unknown accuracy open a new area of possibly revolutionary diagnostic possibilities.

  16. Primary bone marrow oedema syndromes.

    PubMed

    Patel, Sanjeev

    2014-05-01

    MRI scanning in patients with rheumatological conditions often shows bone marrow oedema, which can be secondary to inflammatory, degenerative, infective or malignant conditions but can also be primary. The latter condition is of uncertain aetiology and it is also uncertain whether it represents a stage in the progression to osteonecrosis in some patients. Patients with primary bone marrow oedema usually have lower limb pain, commonly the hip, knee, ankle or feet. The diagnosis is one of exclusion with the presence of typical MRI findings. Treatment is usually conservative and includes analgesics and staying off the affected limb. The natural history is that of gradual resolution of symptoms over a number of months. Evidence for medical treatment is limited, but open-label studies suggest bisphosphonates may help in the resolution of pain and improve radiological findings. Surgical decompression is usually used as a last resort.

  17. Cross-correlative 3D micro-structural investigation of human bone processed into bone allografts.

    PubMed

    Singh, Atul Kumar; Gajiwala, Astrid Lobo; Rai, Ratan Kumar; Khan, Mohd Parvez; Singh, Chandan; Barbhuyan, Tarun; Vijayalakshmi, S; Chattopadhyay, Naibedya; Sinha, Neeraj; Kumar, Ashutosh; Bellare, Jayesh R

    2016-05-01

    Bone allografts (BA) are a cost-effective and sustainable alternative in orthopedic practice as they provide a permanent solution for preserving skeletal architecture and function. Such BA however, must be processed to be disease free and immunologically safe as well as biologically and clinically useful. Here, we have demonstrated a processing protocol for bone allografts and investigated the micro-structural properties of bone collected from osteoporotic and normal human donor samples. In order to characterize BA at different microscopic levels, a combination of techniques such as Solid State Nuclear Magnetic Resonance (ssNMR), Scanning Electron Microscope (SEM), micro-computed tomography (μCT) and Thermal Gravimetric Analysis (TGA) were used for delineating the ultra-structural property of bone. ssNMR revealed the extent of water, collagen fine structure and crystalline order in the bone. These were greatly perturbed in the bone taken from osteoporotic bone donor. Among the processing methods analyzed, pasteurization at 60 °C and radiation treatment appeared to substantially alter the bone integrity. SEM study showed a reduction in Ca/P ratio and non-uniform distribution of elements in osteoporotic bones. μ-CT and MIMICS (Materialize Interactive Medical Image Control System) demonstrated that pasteurization and radiation treatment affects the BA morphology and cause a shift in the HU unit. However, the combination of all these processes restored all-important parameters that are critical for BA integrity and sustainability. Cross-correlation between the various probes we used quantitatively demonstrated differences in morphological and micro-structural properties between BA taken from normal and osteoporotic human donor. Such details could also be instrumental in designing an appropriate bone scaffold. For the best restoration of bone microstructure and to be used as a biomaterial allograft, a step-wise processing method is recommended that preserves all

  18. Os trigonum syndrome on bone SPECT/CT.

    PubMed

    Huang, Jianmin; Servaes, Sabah; Zhuang, Hongming

    2014-08-01

    A 16-year-old female athlete presented with increased pain in the distal left lower extremity. A possible stress fracture or shin splint of the left tibia was first considered. A 3-phase bone scintigraphy showed a very small focus of increased activity in the posterior left foot. A diagnosis of os trigonum syndrome was made after SPECT/CT images pinpointed the activity at the left os trigonum.

  19. Vector generator scan converter

    DOEpatents

    Moore, J.M.; Leighton, J.F.

    1988-02-05

    High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardware for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold. 7 figs.

  20. Vector generator scan converter

    DOEpatents

    Moore, James M.; Leighton, James F.

    1990-01-01

    High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O (input/output) channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardward for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold.

  1. Vector generator scan converter

    SciTech Connect

    Moore, J.M.; Leighton, J.F.

    1990-04-17

    This patent describes high printing speeds for graphics data that are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O (input/output) channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardware for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold.

  2. [The pisiform bone: sesamoid or carpal bone?].

    PubMed

    May, O

    1996-01-01

    In man, the pisiform bone occupies an unusual place among the carpal bones. It is situated in an anterior plane to the other bones, sheathed within the tendon of the flexor carpi ulnaris, and ossifying almost four years the last of the carpal bones. Many theories have tried to explain the presence of this "exceptional" bone: the first theory, proposed by Flower and Mivart, suggested the possibility that this bone could be a sesamoid. The second theory supposes a polydactyl hand, assuming that polydactyly preceded pentadactyly; the pisiform would then be a post-minimus vestigial bone according to Bardeleben. Finally, Gegenbauer and Gillies, proposed a primary pentadactyl hand in which the carpus would be composed of three proximal elements, generally two central, and five distal. The pisiform would either be a derivative of the central series, or a distinct element in the carpus. This last theory appears to be the most likely. The primary carpus would therefore have consisted of 12 bones arranged in 3 distinct rows, a proximal row of 3 bones, a central row of 4 bones, and a distal row of 5 bones. According to this theory, the most ulnar of the central would have been displaced to the medial limit of the carpus, to become the pisiform. PMID:9026058

  3. Adaptive Optical Scanning Holography

    PubMed Central

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  4. Tomographic scanning imager.

    PubMed

    Hovland, Harald

    2009-07-01

    In tomographic scanning (TOSCA) imaging, light from a scene is focused onto a reticle mask using conical scan optics, and collected on a single element detector. Alternatively, one or several detectors replace the reticle. Tomographic processing techniques are then applied to the one-dimensional signal to reproduce a two-dimensional image. The TOSCA technique is presented in detail, including its mathematical foundations and some of its limitations. It is shown how TOSCA imaging can be used in a multispectral configuration, and compares well with more conventional alternatives both in simplicity and performance. Examples of image reconstruction using TOSCA techniques are shown. PMID:19582052

  5. Scanning computed confocal imager

    DOEpatents

    George, John S.

    2000-03-14

    There is provided a confocal imager comprising a light source emitting a light, with a light modulator in optical communication with the light source for varying the spatial and temporal pattern of the light. A beam splitter receives the scanned light and direct the scanned light onto a target and pass light reflected from the target to a video capturing device for receiving the reflected light and transferring a digital image of the reflected light to a computer for creating a virtual aperture and outputting the digital image. In a transmissive mode of operation the invention omits the beam splitter means and captures light passed through the target.

  6. Power trench gate MOSFET with an integrated 6-pack configuration for a 3-phase inverter

    NASA Astrophysics Data System (ADS)

    Won, Jong-Il; Koo, Jin-Gun; Cho, Doo-Hyung; Park, Kun-Sik; Yang, Yil-Suk; Kim, Sang-Gi

    2015-10-01

    In this paper, we present a new 6-pack power module for a 3-phase inverter that is integrated with the six trench gate double diffused metal-oxide semiconductor field-effect transistor (TDMOS) on a single chip. An integration of each power device is performed through a trench isolation technique using deep reactive-ion etching trench technologies. Through this new technology, the integrated power metal-oxide semiconductor field-effect transistor (MOSFET) produces a high current of above 30 A at a gate bias of 10 V. In addition, each trench power MOSFET (1-pack) has a minimum specific on-resistance of 21 mohm.cm2 and a typical breakdown voltage of 95 V. The trench isolation provides good isolation up to 120 V. The measurement results show that this 6-pack structure can successfully be integrated with other analog/driver integrated circuit on a single chip. Furthermore, to monitor the operating current of the MOSFET under an inverter-operating condition, sensing FET is integrated a FET into the main MOSFET source region without compromising either the area or the operation of the MOSFET.

  7. Spontaneous formation of superconducting NiBi{sub 3} phase in Ni-Bi bilayer films

    SciTech Connect

    Siva, Vantari; Senapati, Kartik Prusty, Sudakshina; Sahoo, Pratap K.; Satpati, Biswarup

    2015-02-28

    We report the spontaneous formation of superconducting NiBi{sub 3} phase in thermally evaporated Ni-Bi bilayer films. High reaction-diffusion coefficient of Bi is believed to drive the formation of NiBi{sub 3} during the deposition of Bi on the Ni film. Cross sectional transmission electron microscopy and glancing incidence X-ray depth profiling confirmed the presence of NiBi{sub 3} throughout the top Bi layer. Superconducting transition at ∼3.9 K, close to the bulk value, was confirmed by transport and magnetization measurements. The bilayers were irradiated with varying fluence of 100 MeV Au ions to study the robustness of superconducting order in presence of large concentration of defects. Superconducting parameters of NiBi{sub 3}, such as transition temperature and upper critical field, remained unchanged upto an ion dose of 1 × 10{sup 14} ions/cm{sup 2}. The diffusive formation of NiBi{sub 3} in Ni opens the possibility of studying superconducting proximity effect at a truly clean superconductor-ferromagnet interface.

  8. First-principles study of amorphous Ga4Sb6Te3 phase-change alloys

    NASA Astrophysics Data System (ADS)

    Bouzid, Assil; Gabardi, Silvia; Massobrio, Carlo; Boero, Mauro; Bernasconi, Marco

    2015-05-01

    First-principles molecular dynamics simulations within the density functional theory framework were performed to generate amorphous models of the Ga4Sb6Te3 phase change alloy by quenching from the melt. We find that Ga-Sb and Ga-Te are the most abundant bonds with only a minor amount of Sb-Te bonds participating to the alloy network. Ga and four-coordinated Sb atoms present a tetrahedral-like geometry, whereas three-coordinated Sb atoms are in a pyramidal configuration. The tetrahedral-like geometries are similar to those of the crystalline phase of the two binary compounds GaTe and GaSb. A sizable fraction of Sb-Sb bonds is also present, indicating a partial nanoscale segregation of Sb. Despite the fact that the composition Ga4Sb6Te3 lies on the pseudobinary Ga Sb -Sb2Te3 tie line, the amorphous network can be seen as a mixture of the two binary compounds GaTe and GaSb with intertwined elemental Sb.

  9. Bone grafts in dentistry

    PubMed Central

    Kumar, Prasanna; Vinitha, Belliappa; Fathima, Ghousia

    2013-01-01

    Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation. PMID:23946565

  10. Electrospun nanostructured scaffolds for bone tissue engineering.

    PubMed

    Prabhakaran, Molamma P; Venugopal, J; Ramakrishna, S

    2009-10-01

    The current challenge in bone tissue engineering is to fabricate a bioartificial bone graft mimicking the extracellular matrix (ECM) with effective bone mineralization, resulting in the regeneration of fractured or diseased bones. Biocomposite polymeric nanofibers containing nanohydroxyapatite (HA) fabricated by electrospinning could be promising scaffolds for bone tissue engineering. Nanofibrous scaffolds of poly-l-lactide (PLLA, 860+/-110 nm), PLLA/HA (845+/-140 nm) and PLLA/collagen/HA (310+/-125 nm) were fabricated, and the morphology, chemical and mechanical characterization of the nanofibers were evaluated using scanning electron microscopy, Fourier transform infrared spectroscopy and tensile testing, respectively. The in vitro biocompatibility of different nanofibrous scaffolds was also assessed by growing human fetal osteoblasts (hFOB), and investigating the proliferation, alkaline phosphatase activity (ALP) and mineralization of cells on different nanofibrous scaffolds. Osteoblasts were found to adhere and grow actively on PLLA/collagen/HA nanofibers with enhanced mineral deposition of 57% higher than the PLLA/HA nanofibers. The synergistic effect of the presence of an ECM protein, collagen and HA in PLLA/collagen/HA nanofibers provided cell recognition sites together with apatite for cell proliferation and osteoconduction necessary for mineralization and bone formation. The results of our study showed that the biocomposite PLLA/collagen/HA nanofibrous scaffold could be a potential substrate for the proliferation and mineralization of osteoblasts, enhancing bone regeneration. PMID:19447211

  11. Evaluation of Lunar small animal software for measuring bone mineral content in excised rat bones.

    PubMed

    Kiebzak, G M; Meyer, M H; Meyer, R A

    1999-01-01

    The purpose of this study was to evaluate software from Lunar Corporation (Madison, WI) designed for the measurement of bone mineral content ([BMC],g) in excised rat femurs using dual-energy X-ray absorptiometry (DXA). Femurs were harvested from intact 2- to 12-mo-old female Sprague-Dawley rats, stripped of soft tissues, wrapped in saline-soaked gauze, and frozen at -20 degrees F. Thawed bones were scanned in air on a 1.7-cm-thick Lucite plate that was laid on the manufacturer's supplied Delrin platform. Bones were in an anteroposterior position and scanned in a proximal-to-distal manner. Small animal software version 1.0d was used with a Lunar DPX-L densitometer. Regions of interest (ROIs) were the middle one-third of the diaphysis, a small central area of the distal metaphysis, and the total bone. Precision (n = 6 femurs) was calculated for each region of interest. After DXA scanning, one group of bones (n = 10 femurs) was dried and incinerated in a muffle furnace to obtain bone ash. The ash was then digested in acid and aliquots assayed for calcium using atomic absorption spectrophotometry. This group of bones was used to correlate BMC with ash weight and areal bone mineral density (BMD) with calcium concentration. A second group of bones (n = 14 femurs) was used to correlate BMC with maximal load to failure (N), a biomechanical variable that provides information about bone strength. Precision of repetitive measurements for the three ROIs was 1.2, 3.0, and 0.65%, respectively. Total femur BMC and total femur ash weights were significantly correlated (r = 0.974, p <0.0001). Total femur area BMD (g/cm2) was significantly correlated with calcium concentration (microM) of the bone hydrolysate (r = 0.686, p = 0.029). Total femur BMC and maximum load to midshaft fracture were also significantly correlated (r = 0.914, p<0.0001). The greatest problem with the software was with edge detection: operator intervention was necessary to place edges manually during scan

  12. Bone Health and Osteoporosis.

    PubMed

    Lupsa, Beatrice C; Insogna, Karl

    2015-09-01

    Osteoporosis is characterized by low bone mass and microarchitectural deterioration of bone tissue leading to decreased bone strength and an increased risk of low-energy fractures. Central dual-energy X-ray absorptiometry measurements are the gold standard for determining bone mineral density. Bone loss is an inevitable consequence of the decrease in estrogen levels during and following menopause, but additional risk factors for bone loss can also contribute to osteoporosis in older women. A well-balanced diet, exercise, and smoking cessation are key to maintaining bone health as women age. Pharmacologic agents should be recommended in patients at high risk for fracture.

  13. Ultrafast scanning probe microscopy

    DOEpatents

    Weiss, Shimon; Chemla, Daniel S.; Ogletree, D. Frank; Botkin, David

    1995-01-01

    An ultrafast scanning probe microscopy method for achieving subpicosecond-temporal resolution and submicron-spatial resolution of an observation sample. In one embodiment of the present claimed invention, a single short optical pulse is generated and is split into first and second pulses. One of the pulses is delayed using variable time delay means. The first pulse is then directed at an observation sample located proximate to the probe of a scanning probe microscope. The scanning probe microscope produces probe-sample signals indicative of the response of the probe to characteristics of the sample. The second pulse is used to modulate the probe of the scanning probe microscope. The time delay between the first and second pulses is then varied. The probe-sample response signal is recorded at each of the various time delays created between the first and second pulses. The probe-sample response signal is then plotted as a function of time delay to produce a cross-correlation of the probe sample response. In so doing, the present invention provides simultaneous subpicosecond-temporal resolution and submicron-spatial resolution of the sample.

  14. Ultrafast scanning probe microscopy

    DOEpatents

    Weiss, S.; Chemla, D.S.; Ogletree, D.F.; Botkin, D.

    1995-05-16

    An ultrafast scanning probe microscopy method is described for achieving subpicosecond-temporal resolution and submicron-spatial resolution of an observation sample. In one embodiment of the present claimed invention, a single short optical pulse is generated and is split into first and second pulses. One of the pulses is delayed using variable time delay means. The first pulse is then directed at an observation sample located proximate to the probe of a scanning probe microscope. The scanning probe microscope produces probe-sample signals indicative of the response of the probe to characteristics of the sample. The second pulse is used to modulate the probe of the scanning probe microscope. The time delay between the first and second pulses is then varied. The probe-sample response signal is recorded at each of the various time delays created between the first and second pulses. The probe-sample response signal is then plotted as a function of time delay to produce a cross-correlation of the probe sample response. In so doing, the present invention provides simultaneous subpicosecond-temporal resolution and submicron-spatial resolution of the sample. 6 Figs.

  15. Environmental Scanning Report, 1992.

    ERIC Educational Resources Information Center

    Yao, Min

    In response to the change in the provincial economy from natural-resource-based industries to service-oriented industries, Vancouver Community College (VCC) in British Columbia (BC) conducted an environmental scan of the social and economic trends in the college's service region that will most likely affect prospective students' educational and…

  16. THE 2016 ENVIRONMENTAL SCAN.

    PubMed

    O'Dell, Gene

    2015-09-01

    Every year, the American Hospital Association compiles the Environmental Scan to provide hospital leaders with insight and information about market forces that are likely to affect the health care field. One common theme this year is the pace of change. PMID:26495611

  17. Teaching the SCANS Competencies.

    ERIC Educational Resources Information Center

    Department of Labor, Washington, DC. Secretary's Commission on Achieving Necessary Skills.

    SCANS (the Secretary's Commission on Achieving Necessary Skills) provides definitions of the knowledge students and workers need for workplace success and methods for applying these principles in communities throughout the United States. This document contains six articles that give education and training practitioners practical suggestions for…

  18. Does running strengthen bone?

    PubMed

    Boudenot, Arnaud; Achiou, Zahra; Portier, Hugues

    2015-12-01

    Bone is a living tissue needing mechanical stress to maintain strength. Traditional endurance exercises offer only modest effects on bone. Walking and running produce low impact but lead to bone fatigue. This article is specifically addressed to therapists and explains the mechanisms involved for the effects of exercise on bone. Intermittent exercise limits bone fatigue, and downhill exercises increase ground impact forces and involve eccentric muscle contractions, which are particularly osteogenic. PMID:26562001

  19. [Numerical variants and congenital fusions of carpal bones].

    PubMed

    Senecail, B; Perruez, H; Colin, D

    2007-03-01

    The number of carpal bones may be increased or decreased by the fact of anatomical variants or true congenital anomalies. Numerical increment arises from additional or from split bones. Over twenty accessory carpal bones have been described but the commonest are the os centrale carpi, the os radiale externum, the triangular bone and the styloideum bone. Additional carpal bones usually result from a failure of fusion of their ossification centers. A congenital origin is not clearly established for all these ossicles. The scaphoid and lunate may split into two or three bones and several cases of bipartite hamulus of the hamatum have been reported. A carpus with only seven bones results from the congenital absence of a normal bone, which mainly affects the scaphoid, lunate and triquetrum, or from a synostosis between two carpal bones, usually the lunate and triquetrum. Congenital fusions originate from an absence of joint cavitation into the embryo and chondrification of the joint interzone. Numerical carpal variants are uncommon as independent entities but occur with a relative high frequency in association with complex malformations of the hand. These anomalies are detectable on plain radiographs of the wrist, but CT-scan and MR-Imaging are useful to differentiate bipartite and accessory bones from carpal fractures or posttraumatic injuries, carpal fusions having to be distinguished from bony ankylosis.

  20. Advances in noninvasive bone measurement

    SciTech Connect

    Mazess, R.B.; Barden, H.; Vetter, J.; Ettinger, M.

    1989-01-01

    Several noninvasive measurement methods are used for evaluation of metabolic disease. Single-photon (/sup 125/I) scans of the peripheral skeleton are useful in some diseases but are ineffective in osteoporosis (even on the distal radius or os calcis) because they cannot predict spinal or femoral density. Also, peripheral measurements show high percentages of false negatives, that is many patients with fractures have normal peripheral density. Dual-photon (/sup 153/Gd) scans of the spine, femur, and total skeleton are precise and accurate (2% error) and provide direct measurements of bone strength at fracture sites. This gives the best discrimination of abnormality and the most sensitive monitoring. Quantitative computed computed tomography (QCT) allows measurement of the spine but not the critical proximal femur area. QCT has a large accuracy error because (a) the limited area measured (under 5 cm3) fails to represent the total vertebral body, (b) technical errors, and (c) variable fat and osteoid influence the results. 25 references.

  1. Bone cysts: unicameral and aneurysmal bone cyst.

    PubMed

    Mascard, E; Gomez-Brouchet, A; Lambot, K

    2015-02-01

    Simple and aneurysmal bone cysts are benign lytic bone lesions, usually encountered in children and adolescents. Simple bone cyst is a cystic, fluid-filled lesion, which may be unicameral (UBC) or partially separated. UBC can involve all bones, but usually the long bone metaphysis and otherwise primarily the proximal humerus and proximal femur. The classic aneurysmal bone cyst (ABC) is an expansive and hemorrhagic tumor, usually showing characteristic translocation. About 30% of ABCs are secondary, without translocation; they occur in reaction to another, usually benign, bone lesion. ABCs are metaphyseal, excentric, bulging, fluid-filled and multicameral, and may develop in all bones of the skeleton. On MRI, the fluid level is evocative. It is mandatory to distinguish ABC from UBC, as prognosis and treatment are different. UBCs resolve spontaneously between adolescence and adulthood; the main concern is the risk of pathologic fracture. Treatment in non-threatening forms consists in intracystic injection of methylprednisolone. When there is a risk of fracture, especially of the femoral neck, surgery with curettage, filling with bone substitute or graft and osteosynthesis may be required. ABCs are potentially more aggressive, with a risk of bone destruction. Diagnosis must systematically be confirmed by biopsy, identifying soft-tissue parts, as telangiectatic sarcoma can mimic ABC. Intra-lesional sclerotherapy with alcohol is an effective treatment. In spinal ABC and in aggressive lesions with a risk of fracture, surgical treatment should be preferred, possibly after preoperative embolization. The risk of malignant transformation is very low, except in case of radiation therapy.

  2. Carpal bone analysis in bone age assessment

    NASA Astrophysics Data System (ADS)

    Zhang, Aifeng; Gertych, Arkadiusz; Kurkowska-Pospiech, Sylwia; Liu, Brent J.; Huang, H. K.

    2006-03-01

    A computer-aided-diagnosis (CAD) method has been previously developed in our Laboratory based on features extracted from regions of interest (ROI) in phalanges in a digital hand atlas. Due to various factors, including, the diversity of size, shape and orientation of carpal bones, non-uniformity of soft tissue, low contrast between the bony structure and soft tissue, the automatic identification and segmentation of bone boundaries is an extremely challenging task. Past research work on carpal bone segmentation has been done utilizing dynamic thresholding. However, due to the discrepancy of carpal bones developments and the limitations of segmentation algorithms, carpal bone ROI has not been taken into consideration in the bone age assessment procedure. In this paper, we present a method for fully automatic carpal bone segmentation and feature analysis in hand X-ray radiograph. The purpose of this paper is to automatically segment the carpal bones by anisotropic diffusion and Canny edge detection techniques. By adding their respective features extracted from carpal bones ROI to the phalangeal ROI feature space, the accuracy of bone age assessment can be improved especially when the image processing in the phalangeal ROI fails in younger children.

  3. Innovative approaches to noninvasive bone densitometry

    SciTech Connect

    Sartoris, D.J.; Resnick, D. )

    1990-01-01

    In conclusion, this review has endeavored to familiarize the practicing radiologist with some of the newer approaches to noninvasive bone densitometry that are currently being explored as potential improvements over existing techniques. Three-dimensional volumetric CT is a practical means of measuring bone density in the proximal femur, owing to the widespread availability of the necessary scanning equipment, and affords enhanced prediction of biomechanical parameters in the spine and hip, but suffers from limitations similar to those of conventional quantitative CT. Dual-energy projection radiography offers significant potential advantages over dual-photon absorptiometry from the standpoint of precision, radiation dose, image quality, and examination time, but remains to be thoroughly tested. Compton scattering appears to be a viable alternative to single-photon absorptiometry for bone density determinations in the peripheral skeleton. Neutron and proton activation analysis are unlikely to achieve widespread application, owing to their cyclotron-dependent nature, although the former will probably remain the optimal means for determining total body calcium. Experience with scanning-slit fluorography and magnetic resonance as applied to noninvasive bone densitometry is currently too limited to permit prediction of their ultimate role in this respect. As a final point, it should be noted that major incentives for mobilization of bone densitometric equipment currently exist: on Earth, as a means of facilitating patient access and saving money via joint ventures, and in space for monitoring the adverse effects of weightlessness on skeletal mass and the ability to function following return to a gravity environment.25 references.

  4. Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies

    PubMed Central

    Welch, D; Harken, A D; Randers-Pehrson, G; Brenner, D J

    2015-01-01

    We present the complete construction methodology for an anatomically accurate mouse phantom made using materials which mimic the characteristics of tissue, lung, and bone for radiation dosimetry studies. Phantoms were constructed using 2 mm thick slices of tissue equivalent material which was precision machined to clear regions for insertion of lung and bone equivalent material where appropriate. Images obtained using a 3D computed tomography (CT) scan clearly indicate regions of tissue, lung, and bone that match their position within the original mouse CT scan. Additionally, radiographic films are used with the phantom to demonstrate dose mapping capabilities. The construction methodology presented here can be quickly and easily adapted to create a phantom of any specific small animal given a segmented CT scan of the animal. These physical phantoms are a useful tool to examine individual organ dose and dosimetry within mouse systems that are complicated by density inhomogeneity due to bone and lung regions. PMID:25860401

  5. Histologic and morphologic evaluation of explanted bone anchors from bone-anchored hearing aids.

    PubMed

    Mlynski, Robert; Goldberg, Eva; Ebmeyer, Joerg; Scheich, Matthias; Gattenlöhner, Stefan; Schwager, Konrad; Hagen, Rudolf; Shehata-Dieler, Wafaa

    2009-05-01

    Bone-anchored hearing aids are a standard option in rehabilitation of patients with conductive or mixed hearing loss, and also CROS fitting. However, the skin-penetrating bone anchor repeatedly gives reason for discussion about the risk of infection of surrounding tissues as a major cause of malfunction. In the present study, explanted bone anchors with surrounding bone and soft tissue were examined and compared with the morphology of lost implants. The anchors originated from five patients. Two needed explantation due to deafness with the need of cochlea implantation. A third patient underwent explantation due to meningeal irritation by the bone anchor. Another patient lost the implant due to mechanical stress shortly after implantation. The last implant was lost in a child without apparent reason. All implants were clinically free of infection and had been stable for a median implantation period of 12 months. During the explantation procedure, the fixtures were recovered together with the attached soft tissue and bone. The specimens were examined by light microscopy or scanning electron microscopy (SEM). Sectioning for light microscopy was performed with a diamond-coated saw microtome. Histopathologic examination of the surrounding skin and subcutaneous soft tissue showed slight inflammation in one case only. The bone was regularly vital, presenting no signs of inflammation. The threads of the fixtures were filled with bone, with particularly strong attachment to the flank of traction. The SEM investigation exposed the ultrastructural interaction of bone with the implant surface. Filiform- and podocyte-like processes of osteocytes attach to the implant; lost implants did not reflect these features. Implant integration involves both osseointegration as well as soft tissue integration. Titanium oxide as the active implant surface promotes this integration even in unstable implants. The morphologic analysis exposed structural areas of the implant with weak bone

  6. Chondrogenically differentiated mesenchymal stromal cell pellets stimulate endochondral bone regeneration in critical-sized bone defects.

    PubMed

    van der Stok, J; Koolen, M K E; Jahr, H; Kops, N; Waarsing, J H; Weinans, H; van der Jagt, O P

    2014-02-19

    Grafting bone defects or atrophic non-unions with mesenchymal stromal cells (MSCs)-based grafts is not yet successful. MSC-based grafts typically use undifferentiated or osteogenically differentiated MSCs and regenerate bone through intramembranous ossification. Endochondral ossification might be more potent but requires chondrogenic differentiation of MSCs. Here, we determined if chondrogenically differentiated MSC (ch-MSC) pellets could induce bone regeneration in an orthotopic environment through endochondral ossification. Undifferentiated MSC pellets (ud-MSC) and ch-MSC pellets were generated from MSCs of human donors cultured on chondrogenic medium for respectively 3 (ud-MSC) and 21 (ch-MSC) days. A 6 mm femoral bone defect was made and stabilised with an internal plate in 27 athymic rats. Defects were left empty for 6 weeks to develop an atrophic non-union before they were grafted with ch-MSC pellets or ud-MSC pellets. Micro-CT scans made 4 and 8 weeks after grafting showed that ch-MSC pellets resulted in significantly more bone than ud-MSC pellets. This regenerated bone could completely bridge the defect, but the amount of bone regeneration was donor-dependent. Histology after 7 and 14 days showed slowly mineralising pellets containing hypertrophic chondrocytes, as well as TRAP-positive and CD34-positive cells around the ch-MSC pellets, indicating osteoclastic resorption and vascularisation typical for endochondral ossification. In conclusion, grafting critical femoral bone defects with chondrogenically differentiated MSC pellets led to rapid and pronounced bone regeneration through endochondral ossification and may therefore be a more successful MSC-based graft to repair large bone defects or atrophic non-unions. But, since bone regeneration was donor-depend, the generation of potent chondrogenically differentiated MSC pellets for each single donor needs to be established first.

  7. The effect of autologous bone marrow stromal cells differentiated on scaffolds for canine tibial bone reconstruction.

    PubMed

    Özdal-Kurt, F; Tuğlu, I; Vatansever, H S; Tong, S; Deliloğlu-Gürhan, S I

    2015-01-01

    Bone marrow contains mesenchymal stem cells that form many tissues. Various scaffolds are available for bone reconstruction by tissue engineering. Osteoblastic differentiated bone marrow stromal cells (BMSC) promote osteogenesis on scaffolds and stimulate bone regeneration. We investigated the use of cultured autologous BMSC on different scaffolds for healing defects in tibias of adult male canines. BMSC were isolated from canine humerus bone marrow, differentiated into osteoblasts in culture and loaded onto porous ceramic scaffolds including hydroxyapatite 1, hydroxyapatite gel and calcium phosphate. Osteoblast differentiation was verified by osteonectine and osteocalcine immunocytochemistry. The scaffolds with stromal cells were implanted in the tibial defect. Scaffolds without stromal cells were used as controls. Sections from the defects were processed for histological, ultrastructural, immunohistochemical and histomorphometric analyses to analyze the healing of the defects. BMSC were spread, allowed to proliferate and differentiate to osteoblasts as shown by alizarin red histochemistry, and osteocalcine and osteonectine immunostaining. Scanning electron microscopy showed that BMSC on the scaffolds were more active and adhesive to the calcium phosphate scaffold compared to the others. Macroscopic bone formation was observed in all groups, but scaffolds with stromal cells produced significantly better results. Bone healing occurred earlier and faster with stromal cells on the calcium phosphate scaffold and produced more callus compared to other scaffolds. Tissue healing and osteoblastic marker expression also were better with stromal cells on the scaffolds. Increased trabecula formation, cell density and decreased fibrosis were observed in the calcium phosphate scaffold with stromal cells. Autologous cultured stromal cells on the scaffolds were useful for healing of canine tibial bone defects. The calcium phosphate scaffold was the best for both cell

  8. Bone marrow blood vessel ossification and "microvascular dead space" in rat and human long bone.

    PubMed

    Prisby, Rhonda D

    2014-07-01

    Severe calcification of the bone microvascular network was observed in rats, whereby the bone marrow blood vessels appeared ossified. This study sought to characterize the magnitude of ossification in relation to patent blood vessels and adipocyte content in femoral diaphyses. Additionally, this study confirmed the presence of ossified vessels in patients with arteriosclerotic vascular disease and peripheral vascular disease and cellulitis. Young (4-6 month; n=8) and old (22-24 month; n=8) male Fischer-344 rats were perfused with barium sulfate to visualize patent bone marrow blood vessels. Femoral shafts were processed for bone histomorphometry to quantify ossified (Goldner's Trichrome) and calcified (Alizarin Red) vessels. Adipocyte content was also determined. Additional femora (n=5/age group) were scanned via μCT to quantify microvascular ossification. Bone marrow blood vessels from the rats and the human patients were also isolated and examined via microscopy. Ossified vessels (rats and humans) had osteocyte lacunae on the vessel surfaces and "normal" vessels were transitioning into bone. The volume of ossified vessels was 4800% higher (p<0.05) in the old vs. young rats. Calcified and ossified vessel volumes per tissue volume and calcified vessel volume per patent vessel volume were augmented (p<0.05) 262%, 375% and 263%, respectively, in the old vs. young rats. Ossified and patent vessel number was higher (171%) and lower (40%), respectively, in the old vs. young rats. Finally, adipocyte volume per patent vessel volume was higher (86%) with age. This study is the first to report ossification of bone marrow blood vessels in rats and humans. Ossification presumably results in "microvascular dead space" in regard to loss of patency and vasomotor function as opposed to necrosis. Progression of bone microvascular ossification may provide the common link associated with age-related changes in bone and bone marrow. The clinical implications may be evident in the

  9. Histologic and morphologic evaluation of explanted bone anchors from bone-anchored hearing aids.

    PubMed

    Mlynski, Robert; Goldberg, Eva; Ebmeyer, Joerg; Scheich, Matthias; Gattenlöhner, Stefan; Schwager, Konrad; Hagen, Rudolf; Shehata-Dieler, Wafaa

    2009-05-01

    Bone-anchored hearing aids are a standard option in rehabilitation of patients with conductive or mixed hearing loss, and also CROS fitting. However, the skin-penetrating bone anchor repeatedly gives reason for discussion about the risk of infection of surrounding tissues as a major cause of malfunction. In the present study, explanted bone anchors with surrounding bone and soft tissue were examined and compared with the morphology of lost implants. The anchors originated from five patients. Two needed explantation due to deafness with the need of cochlea implantation. A third patient underwent explantation due to meningeal irritation by the bone anchor. Another patient lost the implant due to mechanical stress shortly after implantation. The last implant was lost in a child without apparent reason. All implants were clinically free of infection and had been stable for a median implantation period of 12 months. During the explantation procedure, the fixtures were recovered together with the attached soft tissue and bone. The specimens were examined by light microscopy or scanning electron microscopy (SEM). Sectioning for light microscopy was performed with a diamond-coated saw microtome. Histopathologic examination of the surrounding skin and subcutaneous soft tissue showed slight inflammation in one case only. The bone was regularly vital, presenting no signs of inflammation. The threads of the fixtures were filled with bone, with particularly strong attachment to the flank of traction. The SEM investigation exposed the ultrastructural interaction of bone with the implant surface. Filiform- and podocyte-like processes of osteocytes attach to the implant; lost implants did not reflect these features. Implant integration involves both osseointegration as well as soft tissue integration. Titanium oxide as the active implant surface promotes this integration even in unstable implants. The morphologic analysis exposed structural areas of the implant with weak bone

  10. Infant formula promotes bone growth in neonatal piglets by enhancing osteoblastogenesis through bone morphogenic protein signaling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Relatively few studies have examined the effects of formula feeding relative to breast-feeding on bone in the neonate. Using peripheral quantitative CT scan and histomorphometric analysis, we demonstrated that neonatal piglets fed with soy-based formula (SF) and cow milk-based formula (MF) for 21 or...

  11. Lung Ventilation/Perfusion Scan

    MedlinePlus

    ... from the NHLBI on Twitter. What Is a Lung Ventilation/Perfusion Scan? A lung ventilation/perfusion scan, or VQ scan, is a ... that measures air and blood flow in your lungs. A VQ scan most often is used to ...

  12. Bioreactor cultivation of anatomically shaped human bone grafts.

    PubMed

    Temple, Joshua P; Yeager, Keith; Bhumiratana, Sarindr; Vunjak-Novakovic, Gordana; Grayson, Warren L

    2014-01-01

    In this chapter, we describe a method for engineering bone grafts in vitro with the specific geometry of the temporomandibular joint (TMJ) condyle. The anatomical geometry of the bone grafts was segmented from computed tomography (CT) scans, converted to G-code, and used to machine decellularized trabecular bone scaffolds into the identical shape of the condyle. These scaffolds were seeded with human bone marrow-derived mesenchymal stem cells (MSCs) using spinner flasks and cultivated for up to 5 weeks in vitro using a custom-designed perfusion bioreactor system. The flow patterns through the complex geometry were modeled using the FloWorks module of SolidWorks to optimize bioreactor design. The perfused scaffolds exhibited significantly higher cellular content, better matrix production, and increased bone mineral deposition relative to non-perfused (static) controls after 5 weeks of in vitro cultivation. This technology is broadly applicable for creating patient-specific bone grafts of varying shapes and sizes.

  13. Bioreactor Cultivation of Anatomically Shaped Human Bone Grafts

    PubMed Central

    Temple, Joshua P.; Yeager, Keith; Bhumiratana, Sarindr; Vunjak-Novakovic, Gordana; Grayson, Warren L.

    2015-01-01

    In this chapter, we describe a method for engineering bone grafts in vitro with the specific geometry of the temporomandibular joint (TMJ) condyle. The anatomical geometry of the bone grafts was segmented from computed tomography (CT) scans, converted to G-code, and used to machine decellularized trabecular bone scaffolds into the identical shape of the condyle. These scaffolds were seeded with human bone marrow-derived mesenchymal stem cells (MSCs) using spinner flasks and cultivated for up to 5 weeks in vitro using a custom-designed perfusion bioreactor system. The flow patterns through the complex geometry were modeled using the FloWorks module of SolidWorks to optimize bioreactor design. The perfused scaffolds exhibited significantly higher cellular content, better matrix production, and increased bone mineral deposition relative to non-perfused (static) controls after 5 weeks of in vitro cultivation. This technology is broadly applicable for creating patient-specific bone grafts of varying shapes and sizes. PMID:24014312

  14. Hematogenous pyogenic vertebral osteomyelitis: diagnostic value of radionuclide bone imaging

    SciTech Connect

    Adatepe, M.H.; Powell, O.M.; Isaacs, G.H.; Nichols, K.; Cefola, R.

    1986-11-01

    Hematogenous pyogenic vertebral osteomyelitis (HPVO) continues to be a diagnostic problem for clinicians due to nonspecific presentation of the disease (1,2). We reviewed our experience of the last 10 years to determine the diagnostic usefulness of radionuclide bone studies in this disease. We found 15 patients whose primary diagnosis was HPVO. Of the 15 patients, 12 had (99mTc)MDP bone scans which were all positive. Five of the 12 patients had positive (/sup 67/Ga)citrate scans and one patient with chronic active HPVO had negative /sup 67/Ga and (/sup 111/In)WBC bone images. At the same time, three patients' spine x-rays and one patient's CT scan of the vertebra were normal. Additionally, in three patients spine x-rays were interpreted as consistent with degenerative joint disease that contributed to the delay of the diagnosis. We conclude that when HPVO is suspected an abnormal (99mTc)MDP bone image increases the probability of the disease, even if the x-rays and CT scans of the spine are normal. An abnormal /sup 67/Ga image following an abnormal 99mTc bone image increases the specificity of the diagnosis. Normal (99mTc)MDP and (/sup 67/Ga)citrate bone images of the vertebra virtually exclude the diagnosis of HPVO.

  15. Bone disease in hypoparathyroidism.

    PubMed

    Clarke, Bart L

    2014-07-01

    Hypoparathyroidism is a rare disorder that may be acquired or inherited. Postsurgical hypoparathyroidism is responsible for the majority of acquired hypoparathyroidism. Bone disease occurs in hypoparathyroidism due to markedly reduced bone remodeling due to the absence or low levels of parathyroid hormone. Chronically reduced bone turnover in patients with hypoparathyroidism typically leads to higher bone mass than in age- and sex-matched controls. Whether this increased bone density reduces fracture risk is less certain, because while increased bone mineralization may be associated with increased brittleness of bone, this does not appear to be the case in hypoparathyroidism. Treatment of hypoparathyroidism with recombinant parathyroid hormone may reduce bone mineral density but simultaneously strengthen the mechanical properties of bone.

  16. Bisphosphonates and bone quality

    PubMed Central

    Pazianas, Michael; van der Geest, Stefan; Miller, Paul

    2014-01-01

    Bisphosphonates (BPs) are bone-avid compounds used as first-line medications for the prevention and treatment of osteoporosis. They are also used in other skeletal pathologies such as Paget's and metastatic bone disease. They effectively reduce osteoclast viability and also activity in the resorptive phase of bone remodelling and help preserve bone micro-architecture, both major determinants of bone strength and ultimately of the susceptibility to fractures. The chemically distinctive structure of each BP used in the clinic determines their unique affinity, distribution/penetration throughout the bone and their individual effects on bone geometry, micro-architecture and composition or what we call ‘bone quality'. BPs have no clinically significant anabolic effects. This review will touch upon some of the components of bone quality that could be affected by the administration of BPs. PMID:24876930

  17. Scanning thermal plumes

    NASA Technical Reports Server (NTRS)

    Scarpace, F. L.; Madding, R. P.; Green, T., III

    1975-01-01

    Over a three-year period 800 thermal line scans of power plant plumes were made by an airborne scanner, with ground truth measured concurrently at the plants. Computations using centered finite differences in the thermal scanning imagery show a lower bound in the horizontal temperature gradient in excess of 1.6 C/m. Gradients persist to 3 m below the surface. Vector plots of the velocity of thermal fronts are constructed by tracing the front motion in successive thermal images. A procedure is outlined for the two-point ground calibration of a thermal scanner from an equation describing the scanner signal and the voltage for two known temperatures. The modulation transfer function is then calculated by input of a thermal step function and application of digital time analysis techniques using Fast Fourier Transforms to the voltage output. Field calibration tests are discussed. Data accuracy is limited by the level of ground truth effort chosen.

  18. Comparative value of bone scintigraphy and radiography in monitoring tumor response in systemially treated prostatic carcinoma

    SciTech Connect

    Levenson, R.M.; Sauerbrunn, B.J.; Bates, H.R.; Newman, R.D.; Eddy, J.L.; Ihde, D.C.

    1983-02-01

    Radionuclide bone scans and skeletal radiographs were obtained before and during combination chemotherapy or initial hormonal treatment in 46 patients with disseminated adenocarcinoma of the prostate. The purpose of the study was to determine the usefulness of these two modalities in evaluating tumor response to therapy. Prior to treatment, bone scans were positive in 44 patients (96%). In all but one patient either bone radiographs or bone marrow biopsy revealed evidence of osseous metastases. In 22 patients partial response to therapy was documented by a variety of other staging tests.Eleven of these patients showed concurrent or later improvement on bone scans; one showed improvement on a radiograph. ''Flare phenomena'' were observed relatively frequently since 23% of the scans and 50% of the radiographs showed worsening at the time of response. Bone scans revealed worsening in 79% of 33 patients with disease progression of extraosseous tumor; radiographs were equally sensitive (82% worsening). It is concluded that bone scans in particular are ueful for monitoring tumor status in systemically treated patients with prostate cancer. However, because of the lack of sensitivity for response and paradoxical worsening with tumor regression in some patients, scans are not accurate enough to be employed as the sole test in following these patients.

  19. Comparative value of bone scintigraphy and radiography in monitoring tumor response in systemically treated prostatic carcinoma

    SciTech Connect

    Levenson, R.M.; Sauerbrunn, B.J.; Bates, H.R.; Newman, R.D.; Eddy, J.L.; Ihde, DC

    1983-02-01

    Radionuclide bone scans and skeletal radiographs were obtained before and during combination chemotherapy or initial hormonal treatment in 46 patients with disseminated adenocarcinoma of the prostate. The purpose of the study was to determine the usefulness of these two modalities in evaluating tumor response to therapy. Prior to treatment, bone scans were positive in 44 patients (96%). In all but one patient either bone radiographs or bone marrow biopsy revealed evidence of osseous metastases. In 22 patients partial response to therapy was documented by a variety of other staging tests. Eleven of these patients showed concurrent or later improvement on bone scans; one showed improvement on a radiograph. Flare phenomena were observed relatively frequently since 23% of the scans and 50% of the radiographs showed worsening at the time of response. Bone scans revealed worsening in 79% of 33 patients with disease progression of extraosseous tumor; radiographs were equally sensitive (82% worsening). It is concluded that bone scans in particular are useful for monitoring tumor status in systemically treated patients with prostate cancer. However, because of the lack of sensitivity for response and paradoxical worsening with tumor regression in some patients, scans are not accurate enough to be employed as the sole test in following these patients.

  20. Fly-scan ptychography

    PubMed Central

    Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; Xu, Weihe; Nazaretski, Evgeny; Harder, Ross; Robinson, Ian K.; Chu, Yong S.

    2015-01-01

    We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. This approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems. PMID:25766519

  1. Scanning micro-sclerometer

    DOEpatents

    Oliver, Warren C.; Blau, Peter J.

    1994-01-01

    A scanning micro-sclerometer measures changes in contact stiffness and correlates these changes to characteristics of a scratch. A known force is applied to a contact junction between two bodies and a technique employing an oscillating force is used to generate the contact stiffness between the two bodies. As the two bodies slide relative to each other, the contact stiffness changes. The change is measured to characterize the scratch.

  2. Fly-scan ptychography

    DOE PAGES

    Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; Xu, Weihe; Nazaretski, Evgeny; Harder, Ross; Robinson, Ian K.; Chu, Yong S.

    2015-03-13

    We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. This approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems.

  3. Scanning micro-sclerometer

    DOEpatents

    Oliver, W.C.; Blau, P.J.

    1994-11-01

    A scanning micro-sclerometer measures changes in contact stiffness and correlates these changes to characteristics of a scratch. A known force is applied to a contact junction between two bodies and a technique employing an oscillating force is used to generate the contact stiffness between the two bodies. As the two bodies slide relative to each other, the contact stiffness changes. The change is measured to characterize the scratch. 2 figs.

  4. Scanning ultrafast electron microscopy

    PubMed Central

    Yang, Ding-Shyue; Mohammed, Omar F.; Zewail, Ahmed H.

    2010-01-01

    Progress has been made in the development of four-dimensional ultrafast electron microscopy, which enables space-time imaging of structural dynamics in the condensed phase. In ultrafast electron microscopy, the electrons are accelerated, typically to 200 keV, and the microscope operates in the transmission mode. Here, we report the development of scanning ultrafast electron microscopy using a field-emission-source configuration. Scanning of pulses is made in the single-electron mode, for which the pulse contains at most one or a few electrons, thus achieving imaging without the space-charge effect between electrons, and still in ten(s) of seconds. For imaging, the secondary electrons from surface structures are detected, as demonstrated here for material surfaces and biological specimens. By recording backscattered electrons, diffraction patterns from single crystals were also obtained. Scanning pulsed-electron microscopy with the acquired spatiotemporal resolutions, and its efficient heat-dissipation feature, is now poised to provide in situ 4D imaging and with environmental capability. PMID:20696933

  5. Scanning holographic lidar telescope

    NASA Technical Reports Server (NTRS)

    Schwemmer, Geary K.; Wilkerson, Thomas D.

    1993-01-01

    We have developed a unique telescope for lidar using a holographic optical element (HOE) as the primary optic. The HOE diffracts 532 nm laser backscatter making a 43 deg angle with a normal to its surface to a focus located 130 cm along the normal. The field of view scans a circle as the HOE rotates about the normal. The detector assembly and baffling remain stationary, compared to conventional scanning lidars in which the entire telescope and detector assembly require steering, or which use a large flat steerable mirror in front of the telescope to do the pointing. The spectral bandpass of our HOE is 50 nm (FWHM). Light within that bandpass is spectrally dispersed at 0.6 nm/mm in the focal plane. An aperture stop reduces the bandpass of light reaching the detector from one direction to 1 nm while simultaneously reducing the field of view to 1 mrad. Wavelengths outside the 50 nm spectral bandpass pass undiffracted through HOE to be absorbed by a black backing. Thus, the HOE combines three functions into one optic: the scanning mirror, the focusing mirror, and a narrowband filter.

  6. Forensic Scanning Electron Microscope

    NASA Astrophysics Data System (ADS)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  7. Bone-immune cell crosstalk: bone diseases.

    PubMed

    Mori, Giorgio; D'Amelio, Patrizia; Faccio, Roberta; Brunetti, Giacomina

    2015-01-01

    Bone diseases are associated with great morbidity; thus, the understanding of the mechanisms leading to their development represents a great challenge to improve bone health. Recent reports suggest that a large number of molecules produced by immune cells affect bone cell activity. However, the mechanisms are incompletely understood. This review aims to shed new lights into the mechanisms of bone diseases involving immune cells. In particular, we focused our attention on the major pathogenic mechanism underlying periodontal disease, psoriatic arthritis, postmenopausal osteoporosis, glucocorticoid-induced osteoporosis, metastatic solid tumors, and multiple myeloma. PMID:26000310

  8. Bone-immune cell crosstalk: bone diseases.

    PubMed

    Mori, Giorgio; D'Amelio, Patrizia; Faccio, Roberta; Brunetti, Giacomina

    2015-01-01

    Bone diseases are associated with great morbidity; thus, the understanding of the mechanisms leading to their development represents a great challenge to improve bone health. Recent reports suggest that a large number of molecules produced by immune cells affect bone cell activity. However, the mechanisms are incompletely understood. This review aims to shed new lights into the mechanisms of bone diseases involving immune cells. In particular, we focused our attention on the major pathogenic mechanism underlying periodontal disease, psoriatic arthritis, postmenopausal osteoporosis, glucocorticoid-induced osteoporosis, metastatic solid tumors, and multiple myeloma.

  9. Descreening of scanned images

    NASA Astrophysics Data System (ADS)

    Kurilin, Ilya V.; Safonov, Ilia V.; Lee, HoKeun; Kim, Sang Ho

    2010-01-01

    Screen or halftone pattern appears on the majority of images printed on electrophotographic and ink-jet printers as well as offset machines. When such halftoned image is scanned, a noisy effect called a Moiré pattern often appears on the image. There are plenty of methods proposed for descreening of images. Common way is adaptive smoothing of scanned images. However the descreening techniques face the following dilemma: deep screen reduction and restoration of contone images leads to blurring of sharp edges of text and other graphics primitives, on the other hand insufficient smoothing keeps screen in halftoned areas. We propose novel descreening algorithm that is primarily intended for preservation of sharpness and contrast of text edges and for restoration contone images from halftone ones accurately. Proposed technique for descreening of scanned images comprises five steps. The first step is decrease of edge transition slope length via local tone mapping with ordering; it is carried out before adaptive smoothing, and it allows better preservation of edges. Adaptive low-pass filter applies simplified idea of Non-Local Means filter for area classification; similarity is calculated between central block of window and different adjacent block that is selected randomly. If similarity is high then current pixel relates to flat region, otherwise pixel relates to edge region. For prevention of edges blurring, flat regions are smoothed stronger than edge regions. By random selection of blocks we avoid the computational overhead related to excessive directional edge detection. Final three stages include additional decrease of edge transition slope length using local tone mapping, increase of local contrast via modified unsharp mask filter, that uses bilateral filter with special edge-stop function for modest smoothing of edges, and global contrast stretching. These stages are intended to compensate decreasing of sharpness and contrast due to low-pass filtering, it allows

  10. Study on the Formation and Precipitation Mechanism of Mn5Si3 Phase in the MBA-2 Brass Alloy

    NASA Astrophysics Data System (ADS)

    Li, Hang; Jie, Jinchuan; Zhang, Pengchao; Jia, Chunxu; Wang, Tongmin; Li, Tingju

    2016-06-01

    Mn5Si3 is an attractive dispersion in the special brass, owing to its high hardness and high wear resistance. In the present study, synchrotron X-ray radiography and rapid cooling were applied to investigate the formation mechanism of Mn5Si3 phase in the MBA-2 brass alloy. The primary Mn5Si3 phase is proved to exist stably in the alloy melt and nucleate from the melt at temperatures above 1373 K (1100 °C). In addition, the precipitation mechanism of Mn5Si3 phase is addressed systematically by the isothermal heat treatment. The Mn5Si3 particles are observed to precipitate from the matrix at temperatures above 1023 K (750 °C), and a crystallographic orientation relationship is found between the precipitated Mn5Si3 particle and β phase: (110)_{β } //(1overline{1} 00)_{{{{Mn}}5 {{Si}}3 }} and [overline{1} 11]_{β } //[11overline{2} overline{2} ]_{{{{Mn}}5 {{Si}}3 }} . However, the precipitation of Mn5Si3 phase is thermodynamically inhibited at lower temperatures, which can be ascribed to the increase in the Gibbs free energy of formation of Mn5Si3 with decreasing the temperature.

  11. OSTEOBLAST ADHESION OF BREAST CANCER CELLS WITH SCANNING ACOUSTIC MICROSCOPY

    SciTech Connect

    Chiaki Miyasaka; Robyn R. Mercer; Andrea M. Mastro; Ken L. Telschow

    2005-03-01

    Breast cancer frequently metastasizes to the bone. Upon colonizing bone tissue, the cancer cells stimulate osteoclasts (cells that break bone down), resulting in large lesions in the bone. The breast cancer cells also affect osteoblasts (cells that build new bone). Conditioned medium was collected from a bone-metastatic breast cancer cell line, MDA-MB-231, and cultured with an immature osteoblast cell line, MC3T3-E1. Under these conditions the osteoblasts acquired a changed morphology and appeared to adherer in a different way to the substrate and to each other. To characterize cell adhesion, MC3T3-E1 osteoblasts were cultured with or without MDA-MB-231 conditioned medium for two days, and then assayed with a mechanical scanning acoustic reflection microscope (SAM). The SAM indicated that in normal medium the MC3T3-E1 osteoblasts were firmly attached to their plastic substrate. However, MC3T3-E1 cells cultured with MDA-MB-231 conditioned medium displayed both an abnormal shape and poor adhesion at the substrate interface. The cells were fixed and stained to visualize cytoskeletal components using optical microscopic techniques. We were not able to observe these differences until the cells were quite confluent after 7 days of culture. However, using the SAM, we were able to detect these changes within 2 days of culture with MDA-MB-231 conditioned medium

  12. Bone Composition Diagnostics: Photoacoustics Versus Ultrasound

    NASA Astrophysics Data System (ADS)

    Yang, Lifeng; Lashkari, Bahman; Mandelis, Andreas; Tan, Joel W. Y.

    2015-06-01

    Ultrasound (US) backscatter from bones depends on the mechanical properties and the microstructure of the interrogated bone. On the other hand, photoacoustics (PA) is sensitive to optical properties of tissue and can detect composition variation. Therefore, PA can provide complementary information about bone health and integrity. In this work, a comparative study of US backscattering and PA back-propagating signals from animal trabecular bones was performed. Both methods were applied using a linear frequency modulation chirp and matched filtering. A 2.2 MHz ultrasonic transducer was employed to detect both signals. The use of the frequency domain facilitates spectral analysis. The variation of signals shows that in addition to sensitivity to mineral changes, PA exhibits sensitivity to changes in the organic part of the bone. It is, therefore, concluded that the combination of both modalities can provide complementary detailed information on bone health than either method separately. In addition, comparison of PA and US depthwise images shows the higher penetration of US. Surface scan images exhibit very weak correlation between US and PA which could be caused by the different signal generation origins in mechanical versus optical properties, respectively.

  13. Image-Based Modeling of Trabecular Bones

    NASA Astrophysics Data System (ADS)

    Rajapakse, Chamith; Gunaratne, Gemunu

    2004-10-01

    Osteoporosis is a major health problem in the U.S. today. The detection and treatment of osteoporosis is currently based on Bone Mineral Density (BMD) measurements. Recent evidence suggests that the low bone mass alone does not account for the entire risk of osteoporotic fractures. It is also been known that the trabecular regions of bones play a major role in the bone strength . Trabecular bone has a complex structure with substantial heterogeneity, anisotropy and asymmetry. Although these properties effect BMD, the role of architecture and tissue material remain uncertain. Computer modeling of trabecular bone can be used predict responses that cannot be obtained experimentally, and they can compute responses that cannot be measured in-vivo. Due to the complexity of the Trabecular Architecture (TA) a model system based on scanned digital images is introduced to get substantial insight of TA and to predict the failure behavior. It is assumed that the added insight provided by these studies will lead to improved diagnostics and treatments of patient-specific osteoporotic fractures.

  14. Characterization of bone microstructure using photoacoustic spectrum analysis.

    PubMed

    Feng, Ting; Perosky, Joseph E; Kozloff, Kenneth M; Xu, Guan; Cheng, Qian; Du, Sidan; Yuan, Jie; Deng, Cheri X; Wang, Xueding

    2015-09-21

    Osteoporosis is a progressive bone disease that is characterized by a decrease in bone mass and the deterioration in bone microarchitecture. This study investigates the feasibility of characterizing bone microstructure by analyzing the frequency spectrum of the photoacoustic (PA) signal from the bone. Modeling and numerical simulation of PA signal were performed on trabecular bone simulations and CT scans with different trabecular thicknesses. The resulting quasi-linear photoacoustic spectra were fittted by linear regression, from which the spectral parameter slope was quantified. The simulation based on two different models both demonstrate that bone specimens with thinner trabecular thicknesses have higher slope. Experiment on osteoporotic rat femoral heads with different mineral content was conducted. The finding from the experiment was in good agreement with the simulation, demonstrating that the frequency-domain analysis of PA signals can provide an objective assessment of bone microstructure and deterioration. Considering that PA measurement is non-ionizing, non-invasive, and has sufficient penetration in both calcified and non-calcified tissues, this new bone evaluation method based on photoacoustic spectral analysis holds potential for clinical management of osteoporosis and other bone diseases.

  15. Tl-201 uptake in bone and soft tissue involvement of sarcoidosis.

    PubMed

    Degirmenci, B; Mavi, A; Ozkal, S; Itil, O; Havitcioglu, H; Ozaksoy, D; Yilmaz, M; Kaya, G C

    2001-06-01

    The authors describe a 38-year-old man who was referred to the nuclear medicine department because of pain and swelling of his fingers in both hands. Tc-99m MDP and Tl-201 scans were performed to evaluate the lesions. A Tc-99m MDP bone scan showed hyperemia and increased uptake in the lesions. A Tl-201 scan showed marked uptake in both early and delayed images in the lesions of his fingers. Bone biopsy and histologic examination confirmed sarcoidosis. This case indicates that Tl-201 uptake can be seen in bone lesions resulting from sarcoidosis. PMID:11353294

  16. Gangrenous Leg in a Patient With Diabetes on MDP Bone Scintigraphy.

    PubMed

    Evbuomwan, Osayande; Akinwale Ayeni, Olusegun; Dhoodhat, Shireen; Di Tamba Vangu, Mboyo

    2016-05-01

    Diabetic patients with peripheral arterial disease frequently experience gangrene of the lower limbs. It has been suggested that a bone scan is useful in differentiating viable from nonviable tissues in patients with extensive peripheral gangrene and thus can help determine the appropriate level of amputation in such patients. We present a 68-year-old diabetic woman with right breast cancer, who was referred to our facility for a bone scan as part of her metastatic workup. Bone scan findings revealed absolute photon deficiency in the distal half of her left lower limb. PMID:26828148

  17. Bone resorption, metastasis, and diphosphonates

    SciTech Connect

    Garattini, S.

    1985-01-01

    This book contains 17 selections. Some of the titles are: Radiotherapy of Bone Lesions; Methodological Problems; Treatment of Bone Metastasis with Antiresorptive Drugs; Control of Bone Cancer Pain; and Chemotherapy of Bone Metastases.

  18. How Is Bone Cancer Diagnosed?

    MedlinePlus

    ... Topic How is bone cancer staged? How is bone cancer diagnosed? A patient’s symptoms, physical exam, and results ... and other imaging tests. Imaging tests to detect bone cancer X-rays Most bone cancers show up on ...

  19. L-arginine prevents bone loss and bone collagen breakdown in cyclosporin A-treated rats.

    PubMed

    Fiore, C E; Pennisi, P; Cutuli, V M; Prato, A; Messina, R; Clementi, G

    2000-11-24

    Cyclosporin A is implicated in the pathogenesis of post-transplantation bone disease. Because of recent evidence that cyclosporin A may cause renal and cardiovascular toxicity by inhibiting nitric oxide (NO) activity, and that NO slows bone remodeling and bone loss in animal and human studies, we investigated a possible link between NO production and beneficial effects on bone health in cyclosporin A-treated rats. Thirty-six 10-week-old male rats were assigned to six groups of six animals each, and treated for 4 weeks with: vehicle; cyclosporin A; L-arginine; N(G)-nitro-L-arginine methylester (L-NAME, a general inhibitor of NO synthase activity); a combination of cyclosporin A+L-arginine; and a combination of cyclosporin A+L-NAME. Whole body and regional (spine and pelvis) bone mineral content of rats were measured under basal conditions and at the end of the treatment period by dual-energy X-ray absorptiometry (DXA) scanning. Femur weights and serum concentrations of pyridinoline, a reliable marker of bone resorption, were measured at the end of the study period. Cyclosporin A-, L-NAME-, and cyclosporin A+L-NAME-treated rats had significantly lower bone mineral content and femur weights, and significantly higher pyridinoline levels than did control animals. The administration of L-arginine appeared to prevent bone loss caused by cyclosporin A, suggesting that this amino acid, which can be converted to produce NO, might prove useful in preventing disturbed bone modeling and inhibition of bone growth associated with cyclosporin A therapy. PMID:11090650

  20. Plastic casts and confocal laser scanning microscopy applied to the observation of enamel tubules in the red Kangaroo (Macropus rufus).

    PubMed

    Suzuki, Masatsugu; Ushijima, Natsumi; Kohno, Ayako; Sawa, Yoshihiko; Yoshida, Shigemitsu; Sekikawa, Mitsuo; Ohtaishi, Noriyuki

    2003-03-01

    Scanning electron microscopy for plastic casts and confocal laser scanning microscopy for Villanueva bone-stained ground sections were used together to observe enamel tubules in red kangaroo molars. Although the tubular structures such as terminals, bends, expansions, splits, divergences and rejoinings in this species were within the variations of marsupial species, their morphological characteristics were demonstrated with extremely clear and persuasive images. Thus, the combined observations of plastic casts by scanning electron microscopy and Villanueva bone-stain sections by confocal laser scanning microscopy were found to be of value for the investigation of enamel tubules and tubular structures in other hard tissues.

  1. Bone Loss in IBD

    MedlinePlus

    ... DENSITY? Although bone seems as hard as a rock, it’s actually living tissue. Throughout your life, old ... available Bone Loss (.pdf) File: 290 KB 733 Third Avenue, Suite 510, New York, NY 10017 | 800- ...

  2. Bone Marrow Diseases

    MedlinePlus

    ... that help with blood clotting. With bone marrow disease, there are problems with the stem cells or ... marrow makes too many white blood cells Other diseases, such as lymphoma, can spread into the bone ...

  3. What Is Bone?

    MedlinePlus

    ... a soft framework, and calcium phosphate is a mineral that adds strength and hardens the framework. This ... bone formation continues at a faster pace than removal until bone mass peaks during the third decade ...

  4. Isolation, cultivation and characterisation of pigeon osteoblasts seeded on xenogeneic demineralised cancellous bone scaffold for bone grafting.

    PubMed

    Harvanová, Denisa; Hornák, Slavomír; Amrichová, Judita; Spaková, Tímea; Mikes, Jaromír; Plsíková, Jana; Ledecký, Valent; Rosocha, Ján

    2014-09-01

    Avian osteoblasts have been isolated particularly from chicken embryo, but data about other functional tissue sources of adult avian osteoblast precursors are missing. The method of preparation of pigeon osteoblasts is described in this study. We demonstrate that pigeon cancellous bone derived osteoblasts have particular proliferative capacity in vitro in comparison to mammalian species and developed endogenous ALP. Calcium deposits formation in vitro was confirmed by alizarin red staining. Only a few studies have attempted to investigate bone grafting and treatment of bone loss in birds. Lack of autologous bone grafts in birds has prompted investigation into the use of avian xenografts for bone augmentation. Here we present a method of xenografting of ostrich demineralised cancellous bone scaffold seeded with allogeneic adult pigeon osteoblasts. Ostrich demineralised cancellous bone scaffold supported proliferation of pigeon osteoblasts during two weeks of co - cultivation in vitro. Scanning electron microscopy demonstrated homogeneous adult pigeon osteoblasts attachment and distribution on the surface of xenogeneic ostrich demineralised cancellous bone. Our preliminary in vitro results indicate that demineralised cancellous bone from ostrich tibia could provide an effective biological support for growth and proliferation of allogeneic osteoblasts derived from cancellous bone of pigeons. PMID:24915787

  5. Isolation, cultivation and characterisation of pigeon osteoblasts seeded on xenogeneic demineralised cancellous bone scaffold for bone grafting.

    PubMed

    Harvanová, Denisa; Hornák, Slavomír; Amrichová, Judita; Spaková, Tímea; Mikes, Jaromír; Plsíková, Jana; Ledecký, Valent; Rosocha, Ján

    2014-09-01

    Avian osteoblasts have been isolated particularly from chicken embryo, but data about other functional tissue sources of adult avian osteoblast precursors are missing. The method of preparation of pigeon osteoblasts is described in this study. We demonstrate that pigeon cancellous bone derived osteoblasts have particular proliferative capacity in vitro in comparison to mammalian species and developed endogenous ALP. Calcium deposits formation in vitro was confirmed by alizarin red staining. Only a few studies have attempted to investigate bone grafting and treatment of bone loss in birds. Lack of autologous bone grafts in birds has prompted investigation into the use of avian xenografts for bone augmentation. Here we present a method of xenografting of ostrich demineralised cancellous bone scaffold seeded with allogeneic adult pigeon osteoblasts. Ostrich demineralised cancellous bone scaffold supported proliferation of pigeon osteoblasts during two weeks of co - cultivation in vitro. Scanning electron microscopy demonstrated homogeneous adult pigeon osteoblasts attachment and distribution on the surface of xenogeneic ostrich demineralised cancellous bone. Our preliminary in vitro results indicate that demineralised cancellous bone from ostrich tibia could provide an effective biological support for growth and proliferation of allogeneic osteoblasts derived from cancellous bone of pigeons.

  6. Nurse exposure doses resulted from bone scintigraphy patient

    NASA Astrophysics Data System (ADS)

    Tunçman, Duygu; Kovan, Bilal; Poyraz, Leyla; ćapali, Veli; Demir, Bayram; Türkmen, Cüneyt

    2016-03-01

    Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It's general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget's disease, investigation of loosening and infection in orthopedic implants. It is applied with using 99mTc labeled radiopharmaceuticals (e.g 99m Tc MDP,99mTc HEDP and 99mTc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. When some patient's situation is not good, patients are hospitalized until the scanning because of patients' close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse's exposure radiations from patient's routine treatment, examination and emergency station.

  7. Bone cysts: unicameral and aneurysmal bone cyst.

    PubMed

    Mascard, E; Gomez-Brouchet, A; Lambot, K

    2015-02-01

    Simple and aneurysmal bone cysts are benign lytic bone lesions, usually encountered in children and adolescents. Simple bone cyst is a cystic, fluid-filled lesion, which may be unicameral (UBC) or partially separated. UBC can involve all bones, but usually the long bone metaphysis and otherwise primarily the proximal humerus and proximal femur. The classic aneurysmal bone cyst (ABC) is an expansive and hemorrhagic tumor, usually showing characteristic translocation. About 30% of ABCs are secondary, without translocation; they occur in reaction to another, usually benign, bone lesion. ABCs are metaphyseal, excentric, bulging, fluid-filled and multicameral, and may develop in all bones of the skeleton. On MRI, the fluid level is evocative. It is mandatory to distinguish ABC from UBC, as prognosis and treatment are different. UBCs resolve spontaneously between adolescence and adulthood; the main concern is the risk of pathologic fracture. Treatment in non-threatening forms consists in intracystic injection of methylprednisolone. When there is a risk of fracture, especially of the femoral neck, surgery with curettage, filling with bone substitute or graft and osteosynthesis may be required. ABCs are potentially more aggressive, with a risk of bone destruction. Diagnosis must systematically be confirmed by biopsy, identifying soft-tissue parts, as telangiectatic sarcoma can mimic ABC. Intra-lesional sclerotherapy with alcohol is an effective treatment. In spinal ABC and in aggressive lesions with a risk of fracture, surgical treatment should be preferred, possibly after preoperative embolization. The risk of malignant transformation is very low, except in case of radiation therapy. PMID:25579825

  8. Bone marrow biopsy

    MedlinePlus

    Biopsy - bone marrow ... A bone marrow biopsy may be done in the health care provider's office or in a hospital. The sample may ... This captures a tiny sample, or core, of bone marrow within the needle. The sample and needle are ...

  9. [Benign bone forming tumors].

    PubMed

    Caufourier, C; Leprovost, N; Guillou-Jamard, M-R; Compère, J-F; Bénateau, H

    2009-09-01

    Benign bone forming tumors typically produce dense bone (osteoma, enostosis) or osteoid tissue (osteoid osteoma, osteoblastoma). Even though these four lesions have distinct characteristics, it is sometimes difficult to tell them apart and to rule out malignant bone forming lesions such as osteosarcoma. The first line treatment is surgical exeresis.

  10. Phase Equilibria of the Cu-Ti-Er System at 773 K (500 °C) and Stability of the CuTi3 Phase

    NASA Astrophysics Data System (ADS)

    Zhan, Yongzhong; Peng, Dan; She, Jia

    2012-11-01

    The phase relationships of the Cu-Ti-Er ternary phase diagram at 773 K (500 °C) were investigated mainly by means of X-ray powder diffraction (XRD), scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS), and differential thermal analysis (DTA). It is confirmed in this work that the binary compounds Cu9Er2 and Cu7Er2 exist in the Cu-Er binary system at 773 K (500 °C). The stability of the CuTi3 phase is confirmed in the Cu-Ti system. After heat treatment at 1023 K (750 °C) for 90 hours, the phase CuTi3 is observed in the microstructure of the alloy 25Cu75Ti. The temperature of the eutectoid transformation, namely, β-Ti ↔ α-Ti + CuTi3, is determined to be 1078 K (805 °C) in this work. The 773 K (500 °C) isothermal section consists of 14 single-phase regions, 25 two-phase regions, and 12 three-phase regions. None of the phases in this system reveals a remarkable homogeneity range at 773 K (500 °C).

  11. Free motion scanning system

    DOEpatents

    Sword, Charles K.

    2000-01-01

    The present invention relates to an ultrasonic scanner system and method for the imaging of a part system, the scanner comprising: a probe assembly spaced apart from the surface of the part including at least two tracking signals for emitting radiation and a transmitter for emitting ultrasonic waves onto a surface in order to induce at least a portion of the waves to be reflected from the part, at least one detector for receiving the radiation wherein the detector is positioned to receive the radiation from the tracking signals, an analyzer for recognizing a three-dimensional location of the tracking signals based on the emitted radiation, a differential converter for generating an output signal representative of the waveform of the reflected waves, and a device such as a computer for relating said tracking signal location with the output signal and projecting an image of the resulting data. The scanner and method are particularly useful to acquire ultrasonic inspection data by scanning the probe over a complex part surface in an arbitrary scanning pattern.

  12. Ultrafast scanning tunneling microscopy

    SciTech Connect

    Botkin, D.A. |

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  13. A-Scan Echoencephalography

    PubMed Central

    White, D. Naldrett

    1966-01-01

    The technique of A-scan echoencephalography is criticized in so far as it lacks objectivity and reproducibility. In the author's laboratory, the M-echo, being of higher amplitude than other intracranial echoes, is distinguished from other echoes by an averaging technique—a time exposure. Double transmission pulses indicate the theoretical position of echoes from the true mid-line and superimposition of far-side echoes ensures that the transducers are correctly aligned. The very considerable difficulties in identifying the anatomical structures giving rise to other echoes seen within the skull are outlined. They are largely due to variations in the reflected energy, depending upon the shape and orientation and position of the various interfaces with respect to the ultrasonic beam. Despite these difficulties and limitations, A-scan echoencephalography appears to have an important part to play as a simple, safe and quick form of neurological examination, if the technique can be made truly objective. ImagesFig. 1Fig. 9Fig. 10 PMID:5901162

  14. Advanced Ultrasonic Tomograph of Children's Bones

    NASA Astrophysics Data System (ADS)

    Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe

    This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.

  15. A fish bone-related hepatic abscess

    PubMed Central

    Jarry, Julien; Nguyen, Vien; Stoltz, Adeline; Imperato, Marc; Michel, Philippe

    2011-01-01

    We report an unusual case of pyogenic, hepatic abscess caused by fish bone penetration of the duodenum in a 68-year-old woman. The fish bone had migrated into the liver through the duodenal wall. The patient was initially admitted to our emergency room with abdominal pain, fever, and asthenia. A contrastenhanced abdominal coputed tomography (CT) scan showed a hepatic abscess in relation with a straight, foreign body, which had entered through the duodenal wall. Surgery was necessary to remove the foreign body, which was identified as a fish bone. The patient's recovery was uneventful and she was discharged on postoperative day 10. This case is discussed together with the data collected by a medline-based extensive review of the literature. PMID:24765356

  16. Computed tomographic anatomy of the temporal bone

    SciTech Connect

    Virapongse, C.; Rothman, S.L.G.; Kier, E.L.; Sarwar, M.

    1982-10-01

    With the recent development of high-resolution computed tomography (CT), there is a growing need to explore the full potential of this new method in demonstrating the detailed anatomy of the temporal bone. For this purpose, dry skulls with intact ossicles were scanned in axial and coronal projections. The detailed CT anatomy of the temporal bone was documented, complemented by images from live patients. Because of its superior contrast resolution, CT was able to demonstrate numerous structures, such as the tympanic membrane, ossicles, and supporting structures, hitherto never or poorly visualized by any other method. In addition, the ease by which axial sections of the temporal bone could be obtained is of great benefit in displaying several structures previously difficult to evaluate.

  17. Dynamic radioisotope bone imaging as a noninvasive indicator of canine tibial blood flow

    SciTech Connect

    Nutton, R.W.; Fitzgerald, R.H. Jr.; Brown, M.L.; Kelly, P.J.

    1984-01-01

    The relative values of dynamic and static bone imaging with hydroxymethylenediphosphonate technetium /sup 99m/ (/sup 99m/Tc HDP) as an indicator of bone blood flow was investigated in the tibia of mature dogs. The dynamic bone scan consisted of 60 1-s images formed after the intravenous injection of /sup 99m/Tc HDP, and the static bone scan was a 45-min uptake image. Blood flow to the tibia was determined by using radioactively labeled microspheres. Studies were carried out in control dogs, in dogs in which blood flow was increased in one leg with ATP, and in dogs in which blood flow was decreased in one leg with norepinephrine. A significant linear relationship between the dynamic scan values and bone blood flow was found at a wide range of blood flow rates. When blood flow increased by more than 50%, the effects of diffusion limitation were seen in the static scans: increase in tracer uptake was disproportionately small for a significant increase in blood flow. There is no method currently available for estimating bone blood flow by a noninvasive technique. The method described here may be useful for providing a semiquantitative measure of bone blood flow. This improved versatility of bone imaging may have a role in the management of osteomyelitis or complicated fractures, or in assessing the viability of vascularized bone grafts.

  18. X-ray microscopy study of bone mineralization

    NASA Astrophysics Data System (ADS)

    Salomé, M.; Lafage-Proust, M. H.; Vico, L.; Amblard, D.; Kaulich, B.; Oestreich, S.; Susini, J.; Barrett, R.

    2000-05-01

    Transmission spectro-microscopy around the calcium K-edge and fluorescence microscopy were performed respectively on the Transmission X-ray Microscope (TXM) and Scanning X-ray Microscope (SXM) end-stations of ID21 beamline at ESRF, to map the calcium distribution and the Ca/P ratio in bone samples. Preliminary results are presented. The motivation for these experiments is the study of the genetic determinism of bone mineralisation parameters in two different strains of mice.

  19. Visualization of the liver, gallbladder, and intestine on bone scintigraphy

    SciTech Connect

    Sherkow, L.; Ryo, U.Y.; Fabich, D.; Patel, G.C.; Pinsky, S.M.

    1984-08-01

    Images of the liver, gallbladder, and/or intestine were visualized on bone scans on several occasions. Radiopharmaceutical quality control data, including molybdenum-99 and aluminum ion content in the Tc-99m eluate, free unbound Tc-99m, and hydrolyzed reduced Tc-99m in the labeled MDP, were all satisfactory. A minor defect in the quality of the Tc-99m generator was considered to be the probable cause of the unusual localization of the bone imaging agent.

  20. Bone Diseases - Multiple Languages: MedlinePlus

    MedlinePlus

    ... 繁體中文) French (français) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Russian (Русский) Somali (af Soomaali) Spanish (español) ... 骨スキャン - 日本語 (Japanese) Bilingual PDF Health Information Translations Korean (한국어) Bone Scan 골 (骨) 스캔 - 한국어 (Korean) ...

  1. [Bone quality and strength relating with bone remodeling].

    PubMed

    Mori, Satoshi

    2016-01-01

    The bone has the functions of mineral reservoir and mechanical support as skeleton. Bone remodeling is the adult mode of bone metabolism, replacing old bone tissue to new one. Bone strength is determined by bone volume, structure and quality such as micro damage, degree of mineralization and collagen cross linkage, which are all controlled by bone remodeling. Bone strength decreases under high turn-over condition by decreasing bone volume and deterioration of bone structure, which also decreases under low turn-over condition by increased micro damage, increasing mineralization and AGE collagen cross linkage.

  2. Prospective Analysis of Secondary Alveolar Bone Grafting in Cleft Lip and Palate Patients

    PubMed Central

    Reddy, M Gokul Chandra; Babu, V Ramesh; Rao, V Eswar; Chaitanya, J Jaya; Allareddy, S; Reddy, C Charan Kumar

    2015-01-01

    Background: To assess the success of the uptake of bone graft in cleft alveolus of the cleft lip and palate patients, quantitatively through computed tomography (CT) scan 6 months postoperative. To assess the successful eruption of permanent lateral incisor or canine in the bone grafted area. Materials and Methods: The children age group of 9-21 years with unilateral cleft lip and palate came to the hospital, needing secondary alveolar bone grafting. A detailed history and clinical examination of the patient was taken. A 3D CT scan was taken and the volume of the cleft was measured pre-operatively. After ambulatory period, 3D CT scan of the alveolar cleft region was taken and volume of the bone grafted was measured and patient was discharged from the hospital. After 6 months, patient was recalled and again 3D CT scan was taken and the volume of remaining bone was measured. Results: The mean volume of the defect pre-operatively is 0.80 cm3 with a standard deviation of 0.36 cm3 with minimum volume of the defect 0.44 cm3 and maximum volume of the defect 1.60 cm3. The mean volume of the bone post-operative immediately after grafting is 1.01 cm3 with a standard deviation of 0.52 cm3 with minimum of bone volume is 0.48 cm3 and maximum of 2.06 cm3. The mean volume of the bone after 6 months after bone grafting is 0.54 cm3 with a standard deviation of 0.33 cm3, minimum bone volume of 0.22 cm3 and maximum bone volume of 1.42 cm3. Conclusion: The CT scan is a valuable radiographic imaging modality to assess and follow the clinical outcome of secondary alveolar bone grafting. PMID:25954076

  3. Oxytocin and bone

    PubMed Central

    Sun, Li; Zaidi, Mone; Zallone, Alberta

    2014-01-01

    One of the most meaningful results recently achieved in bone research has been to reveal that the pituitary hormones have profound effect on bone, so that the pituitary-bone axis has become one of the major topics in skeletal physiology. Here, we discuss the relevant evidence about the posterior pituitary hormone oxytocin (OT), previously thought to exclusively regulate parturition and breastfeeding, which has recently been established to directly regulate bone mass. Both osteoblasts and osteoclasts express OT receptors (OTR), whose stimulation enhances bone mass. Consistent with this, mice deficient in OT or OTR display profoundly impaired bone formation. In contrast, bone resorption remains unaffected in OT deficiency because, even while OT stimulates the genesis of osteoclasts, it inhibits their resorptive function. Furthermore, in addition to its origin from the pituitary, OT is also produced by bone marrow osteoblasts acting as paracrine-autocrine regulator of bone formation modulated by estrogens. In turn, the power of estrogen to increase bone mass is OTR-dependent. Therefore, OTR−/− mice injected with 17β-estradiol do not show any effects on bone formation parameters, while the same treatment increases bone mass in wild-type mice. These findings together provide evidence for an anabolic action of OT in regulating bone mass and suggest that bone marrow OT may enhance the bone-forming action of estrogen through an autocrine circuit. This established new physiological role for OT in the maintenance of skeletal integrity further suggests the potential use of this hormone for the treatment of osteoporosis. PMID:25209411

  4. Derivation of Instantaneous Wye and Zero-Phase Sequence Voltages from Line-Line Voltages in Unbalanced 3-Phase 3-Wire Systems and Application of This Method to 3-Phase PWM Converter Control

    NASA Astrophysics Data System (ADS)

    Yuzurihara, Itsuo; Kawamura, Atsuo

    In general, voltage imbalances in 3-phase AC power systems are inevitable. 3-Phase PWM (Pulse Width Modulation) converter used in 3-wire systems are generally designed for use under limited imbalances of input voltages, and problems such as input current distortion, deterioration of output properties, degradation of efficiency and failure may occur in some cases. These problems cause severe damages to industries in some cases, for example, semiconductor production machines: SEMI defined “SEMI F47-0200” and “SEMI F47-0706” standards that have to be satisfied to realize voltage sag immunity. In order to compensate the remained problems due to the unbalanced input voltages, particular storage devices are designed additionally for conventional converters. This paper proposes that the determination of both the instantaneous zero-phase sequence voltage and wye voltages is essential for 3-phase PWM converter control used for a 3-wire system to keep its output rated under occasional or long-term voltage imbalances in an AC system. This paper also describes a general new method to derive the components of the voltages of instantaneous wye and zero-phase sequence voltage from line-line voltages of a 3-wire system. This paper also describes a method to apply the voltages to control the converter. The results obtained on implementation verify that this new converter keeps its output rated under unbalanced conditions wider than those defined by SEMIs without particular storage devices as far as the AC voltages are remained live.

  5. False Suggestion of Malignant Transformation of Benign Bone Tumor by 18F-FDG PET/CT: A Potential Pitfall.

    PubMed

    Chen, Yu-Ren; Kuo, Yu-Cheng; Hsu, Cheng-Nan; Hsieh, Te-Chun; Kao, Chia-Hung

    2016-10-01

    A 68-year-old man underwent serial F-FDG PET/CT scan follow-up for lung cancer. Then 5.5 years after the initial F-FDG PET/CT scan, the presumed benign bone tumor in the left clavicle showed markedly increased FDG uptake during follow-up; in contrast, the Tc-MDP bone scan paradoxically exhibited no apparent interval change since last bone scan 5.5 years earlier. He underwent a CT-guided biopsy, and the pathological diagnosis was benign fibrous histiocytoma. The result was consistent with the lack of progression in Tc-MDP bone scan, whereas the F-FDG PET/CT scan gave a false-positive impression of malignant transformation. PMID:27556801

  6. [Prefabrication of bone transplants].

    PubMed

    Jagodzinski, M; Kokemüller, H; Jehn, P; Vogt, P; Gellrich, N-C; Krettek, C

    2015-03-01

    Prefabrication of bone transplants is a promising option for large defects of the long bones, especially if there is compromised vascularization of the defect. This is especially true for postinfection bone defects and other types of atrophic nonunion. The generation of a foreign body membrane (Masquelet's technique) has been investigated in order to ameliorate the response of the host tissue surrounding the defect. In an experimental animal study, a blood vessel within a bone construct could be used to generate customized, vascularized osteogenic constructs that can be used to treat large bone defects in the future.

  7. Method for fusing bone

    DOEpatents

    Mourant, Judith R.; Anderson, Gerhard D.; Bigio, Irving J.; Johnson, Tamara M.

    1996-01-01

    Method for fusing bone. The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  8. Pituitary diseases and bone.

    PubMed

    Mazziotti, Gherardo; Chiavistelli, Silvia; Giustina, Andrea

    2015-03-01

    Pituitary hormones have direct and indirect effects on bone remodeling, and skeletal fragility is a frequent complication of pituitary diseases. Fragility fractures may occur in many patients with prolactinomas, acromegaly, Cushing disease, and hypopituitarism. As in other forms of secondary osteoporosis, pituitary diseases generally affect bone quality more than bone quantity, and fractures may occur even in the presence of normal or low-normal bone mineral density, making difficult the prediction of fractures in these settings. Treatment of excess and defective pituitary hormone generally improves skeletal health, although some patients remain at high risk for fractures, necessitating treatment with bone-active drugs.

  9. Quadrature wavelength scanning interferometry.

    PubMed

    Moschetti, Giuseppe; Forbes, Alistair; Leach, Richard K; Jiang, Xiang; O'Connor, Daniel

    2016-07-10

    A novel method to double the measurement range of wavelength scanning interferometery (WSI) is described. In WSI the measured optical path difference (OPD) is affected by a sign ambiguity, that is, from an interference signal it is not possible to distinguish whether the OPD is positive or negative. The sign ambiguity can be resolved by measuring an interference signal in quadrature. A method to obtain a quadrature interference signal for WSI is described, and a theoretical analysis of the advantages is reported. Simulations of the advantages of the technique and of signal errors due to nonideal quadrature are discussed. The analysis and simulation are supported by experimental measurements to show the improved performances. PMID:27409307

  10. Scanning electrochemical microscopy.

    PubMed

    Amemiya, Shigeru; Bard, Allen J; Fan, Fu-Ren F; Mirkin, Michael V; Unwin, Patrick R

    2008-01-01

    This review describes work done in scanning electrochemical microscopy (SECM) since 2000 with an emphasis on new applications and important trends, such as nanometer-sized tips. SECM has been adapted to investigate charge transport across liquid/liquid interfaces and to probe charge transport in thin films and membranes. It has been used in biological systems like single cells to study ion transport in channels, as well as cellular and enzyme activity. It is also a powerful and useful tool for the evaluation of the electrocatalytic activities of different materials for useful reactions, such as oxygen reduction and hydrogen oxidation. SECM has also been used as an electrochemical tool for studies of the local properties and reactivity of a wide variety of materials, including metals, insulators, and semiconductors. Finally, SECM has been combined with several other nonelectrochemical techniques, such as atomic force microscopy, to enhance and complement the information available from SECM alone.

  11. Scanning quantum decoherence microscopy

    NASA Astrophysics Data System (ADS)

    Cole, Jared H.; Hollenberg, Lloyd C. L.

    2009-12-01

    The use of qubits as sensitive nanoscale magnetometers has been studied theoretically and recently demonstrated experimentally. In this paper we propose a new concept, in which a scanning two-state quantum system is used to probe a sample through the subtle effects of decoherence. Mapping both the Hamiltonian and decoherence properties of a qubit simultaneously provides a unique image of the magnetic (or electric) field properties at the nanoscale. The resulting images are sensitive to the temporal as well as spatial variation in the fields created by the sample. As examples we theoretically study two applications; one from condensed matter physics, the other biophysics. The individual components required to realize the simplest version of this device (characterization and measurement of qubits, nanoscale positioning) have already been demonstrated experimentally.

  12. A scanning cavity microscope.

    PubMed

    Mader, Matthias; Reichel, Jakob; Hänsch, Theodor W; Hunger, David

    2015-01-01

    Imaging the optical properties of individual nanosystems beyond fluorescence can provide a wealth of information. However, the minute signals for absorption and dispersion are challenging to observe, and only specialized techniques requiring sophisticated noise rejection are available. Here we use signal enhancement in a high-finesse scanning optical microcavity to demonstrate ultra-sensitive imaging. Harnessing multiple interactions of probe light with a sample within an optical resonator, we achieve a 1,700-fold signal enhancement compared with diffraction-limited microscopy. We demonstrate quantitative imaging of the extinction cross-section of gold nanoparticles with a sensitivity less than 1 nm(2); we show a method to improve the spatial resolution potentially below the diffraction limit by using higher order cavity modes, and we present measurements of the birefringence and extinction contrast of gold nanorods. The demonstrated simultaneous enhancement of absorptive and dispersive signals promises intriguing potential for optical studies of nanomaterials, molecules and biological nanosystems. PMID:26105690

  13. Metrological scanning probe microscope

    NASA Astrophysics Data System (ADS)

    Dorozhovets, N.; Hausotte, T.; Manske, E.; Jäger, G.; Hofmann, N.

    2006-04-01

    Today's technological progress calls for metrologically accurate object measurement, positioning and scanning with nanometre precision and over large measuring ranges. In order to meet that requirement a nanopositioning and nanomeasuring machine (NPM machine) was developed at the Institute of Process Measurement and Sensor Technology of the Technische Universitaet Ilmenau. This device is capable of highly exact long-range positioning and measurement of objects with a resolution of less than 0.1 nm. Due to the structure of the machine many different probe systems can be installed, including scanning probe microscopes (SPMs). A few SPMs have outstanding metrological characteristics and many commercial microscopes only perform as image acquisition tools. Commercial SPMs use piezoelectric actuators in order to move either the sample or the probe. The position measurement sometimes results from the applied voltage to the piezoelectric actuators or from the strain gauge or capacitive displacement sensor data. This means that they suffer from hysteresis, creep, nonlinear characteristics and Abbe offsets. For an accurate measurement the position of the cantilever must be measured in addition to the torsion and bending. The best solution is a combined detection system with a single laser beam. This system has been realized with a special interferometer system, in which the measuring beam is focused on the cantilever backside using a lens. The reflected beam is split with a part being detected by a quadrant photo-diode and the other part being fed back into the interferometer for position measurement. The quadrant photo-diode is used to detect the cantilever torsion and bending.

  14. Rapid scanning mass spectrometer

    SciTech Connect

    Leckey, J.H.; Boeckmann, M.D.

    1996-11-25

    Mass spectrometers and residual gas analyzers (RGA) are used in a variety of applications for analysis of volatile and semi-volatile materials. Analysis is performed by detecting fragments of gas molecules, based on their mass to charge ratio, which are generated in the mass spectrometer. When used as a detector for a gas chromatograph, they function as a means to quantitatively identify isolated volatile species which have been separated from other species via the gas chromatograph. Vacuum Technology, Inc., (VTI) produces a magnetic sector mass spectrometer/RGA which is used in many industrial and laboratory environments. In order to increase the utility of this instrument, it is desirable to increase the mass scanning speed, thereby increasing the number of applications for which it is suited. This project performed the following three upgrades on the computer interface. (1) A new electrometer was designed and built to process the signal from the detector. This new electrometer is more sensitive, over 10 times faster, and over 100 times more stable than the electrometer it will replace. (2) The controller EPROM was reprogrammed with new firmware. This firmware acts as an operating system for the interface and is used to shuttle communications between the PC and the AEROVAC mass spectrometer. (3) The voltage regulator which causes the ion selector voltage to ramp to allow ions of selected mass to be sequentially detected was redesigned and prototyped. The redesigned voltage regulator can be ramped up or down more than 100 times faster than the existing regulator. These changes were incorporated into a prototype unit and preliminary performance testing conducted. Results indicated that scanning speed was significantly increased over the unmodified version.

  15. Sodium 18F-Fluoride Bone Scintigraphy in Deep Ocean Diver.

    PubMed

    Lim, Jin T E; Moncayo, Valeria M; Alazraki, Naomi

    2015-07-01

    Sodium ¹⁸F-fluoride (NaF) is a diagnostic marker for new bone formation in bone scintigraphy that was approved by US FDA in 1972 but discontinued in 1984. We report a case of a US naval officer who spent time living and working in an oceanic lab, 205 feet below the surface. Plain skeletal films of femurs 4 years later demonstrate bilateral bone infarcts. Corresponding sodium ¹⁸F-fluoride bone scintigraphy demonstrates low-normal to decreased tracer activity. This rectilinear scan image is of historical interest. Other bone scintigraphic radiotracers used in the past and present will be briefly discussed.

  16. Modelling of macrosegregation in direct chill casting considering columnar-to-equiaxed transition using 3-phase Eulerian approach

    NASA Astrophysics Data System (ADS)

    Hao, J.; Lin, Y. J.; Nie, Y.; Wu, M.; Ludwig, A.

    2015-06-01

    A 3-phase Eulerian approach is used to model the macrosegregation during solidification in direct chill (DC) casting of binary bronze (Cu-Sn). The three phases are the melt, the solidifying columnar dendrites and the equiaxed grains. The thermodynamic information of Cu-Sn is included based on published thermodynamic data, which are coupled with the 3-phase solidification model. The occurrence of columnar-to-equiaxed transition (CET), phase interactions, feeding flow, equiaxed sedimentation and their influence on macrosegregation are considered in the model. The model is applied to a laboratory DC casting process of bronze as a benchmark to demonstrate the model potentials. The simulation results of mixed columnar and equiaxed solidification as well as the formation of macrosegregation are presented. The focus of this work is to analyze and discuss the macrosegregation mechanisms by different flow including feeding flow and crystal sedimentation.

  17. Bone scintiscanning updated.

    PubMed

    Lentle, B C; Russell, A S; Percy, J S; Scott, J R; Jackson, F I

    1976-03-01

    Use of modern materials and methods has given bone scintiscanning a larger role in clinical medicine, The safety and ready availability of newer agents have led to its greater use in investigating both benign and malignant disease of bone and joint. Present evidence suggests that abnormal accumulation of 99mTc-polyphosphate and its analogues results from ionic deposition at crystal surfaces in immature bone, this process being facilitated by an increase in bone vascularity. There is, also, a component of matrix localization. These factors are in keeping with the concept that abnormal scintiscan sites represent areas of increased osteoblastic activity, although this may be an oversimplification. Increasing evidence shows that the bone scintiscan is more sensitive than conventional radiography in detecting focal disease of bone, and its ability to reflect the immediate status of bone further complements radiographic findings. The main limitation of this method relates to nonspecificity of the results obtained.

  18. Nanomaterials and bone regeneration

    PubMed Central

    Gong, Tao; Xie, Jing; Liao, Jinfeng; Zhang, Tao; Lin, Shiyu; Lin, Yunfeng

    2015-01-01

    The worldwide incidence of bone disorders and conditions has been increasing. Bone is a nanomaterials composed of organic (mainly collagen) and inorganic (mainly nano-hydroxyapatite) components, with a hierarchical structure ranging from nanoscale to macroscale. In consideration of the serious limitation in traditional therapies, nanomaterials provide some new strategy in bone regeneration. Nanostructured scaffolds provide a closer structural support approximation to native bone architecture for the cells and regulate cell proliferation, differentiation, and migration, which results in the formation of functional tissues. In this article, we focused on reviewing the classification and design of nanostructured materials and nanocarrier materials for bone regeneration, their cell interaction properties, and their application in bone tissue engineering and regeneration. Furthermore, some new challenges about the future research on the application of nanomaterials for bone regeneration are described in the conclusion and perspectives part. PMID:26558141

  19. Bone kidney interactions.

    PubMed

    Nickolas, Thomas L; Jamal, Sophie A

    2015-06-01

    The fact that bone disease and kidney disease co-exist is well known. Formally, this inter-relationship is called chronic kidney disease mineral bone disorder or CKD-MBD. Traditionally, it was thought that bone played a passive role in CKD-MBD - specifically that kidney disease caused disordered mineral metabolism which resulted in bone disease and ultimately fractures. More recently however our understanding of bone function in general and the role that bone plays in CKD-MBD in particular, has changed. This chapter will briefly review epidemiology of fractures in chronic kidney disease (CKD) and the roles that imaging and measuring markers of mineral metabolism can play in assessing fracture risk. We will then review more recent data consistent with the concept MBD occurs early in the course of CKD and, via the secretion of novel molecules and/or signalling pathways, the bone can influence other organ systems. PMID:26156535

  20. Bone regeneration in dentistry

    PubMed Central

    Tonelli, Paolo; Duvina, Marco; Barbato, Luigi; Biondi, Eleonora; Nuti, Niccolò; Brancato, Leila; Rose, Giovanna Delle

    2011-01-01

    Summary The edentulism of the jaws and the periodontal disease represent conditions that frequently leads to disruption of the alveolar bone. The loss of the tooth and of its bone of support lead to the creation of crestal defects or situation of maxillary atrophy. The restoration of a functional condition involves the use of endosseous implants who require adequate bone volume, to deal with the masticatory load. In such situations the bone need to be regenerated, taking advantage of the biological principles of osteogenesis, osteoinduction and osteoconduction. Several techniques combine these principles with different results, due to the condition of the bone base on which we operate changes, the surgical technique that we use, and finally for the bone metabolic conditions of the patient who can be in a state of systemic osteopenia or osteoporosis; these can also affect the result of jaw bone reconstruction. PMID:22461825

  1. [Bone and Nutrition. Bone and phosphorus intake].

    PubMed

    Arai, Hidekazu; Sakuma, Masae

    2015-07-01

    Phosphorus is necessary for bone mineralization. Although adequate phosphorus intake is essential for skeletal mineralization, it is reported that excessive phosphorus intake can induce deleterious effect on bone. Recently, since the Japanese diet has been westernized, phosphorus intake by the meat and dairy products has increased. Furthermore, along with the development of processed foods, excessive intake of inorganic phosphorus from food additives has become a problem. An adverse effect on parathyroid hormone (PTH) secretion from high phosphorus intake was seen only when calcium intake was inadequate. Dietary calcium to phosphorus ratio can be considered as one of the indicators that can predict the health of the bone.

  2. Marble Bone Disease: A Rare Bone Disorder

    PubMed Central

    Harinathbabu, Maheswari; Thillaigovindan, Ranjani; Prabhu, Geetha

    2015-01-01

    Osteopetrosis, or marble bone disease, is a rare skeletal disorder due to a defective function of the osteoclasts. This defect renders bones more susceptible to osteomyelitis due to decreased vascularity. This disorder is inherited as autosomal dominant and autosomal recessive. Healthcare professionals should urge these patients to maintain their oral health as well as general health, as this condition makes these patients more susceptible to frequent infections and fractures. This case report emphasizes the signs and symptoms of marble bone disease and presents clinical and radiographic findings.  PMID:26594603

  3. [Bone and Nutrition. Bone and phosphorus intake].

    PubMed

    Arai, Hidekazu; Sakuma, Masae

    2015-07-01

    Phosphorus is necessary for bone mineralization. Although adequate phosphorus intake is essential for skeletal mineralization, it is reported that excessive phosphorus intake can induce deleterious effect on bone. Recently, since the Japanese diet has been westernized, phosphorus intake by the meat and dairy products has increased. Furthermore, along with the development of processed foods, excessive intake of inorganic phosphorus from food additives has become a problem. An adverse effect on parathyroid hormone (PTH) secretion from high phosphorus intake was seen only when calcium intake was inadequate. Dietary calcium to phosphorus ratio can be considered as one of the indicators that can predict the health of the bone. PMID:26119308

  4. Development of a biointegrated mandibular reconstruction device consisting of bone compatible titanium fiber mesh scaffold.

    PubMed

    Hirota, Makoto; Shima, Takaki; Sato, Itaru; Ozawa, Tomomichi; Iwai, Toshinori; Ametani, Akihiro; Sato, Mitsunobu; Noishiki, Yasuharu; Ogawa, Takahiro; Hayakawa, Tohru; Tohnai, Iwai

    2016-01-01

    Coating biomaterials with a thin hydroxyapatite (HA) was proven effective in enhancing bone compatibility. Segmental bone defects are considered as the most difficult defect to repair in bone regeneration therapy. We developed submicron-thin HA-coated titanium fiber mesh scaffolds to reconstruct immediately loaded segmental mandibular defects and evaluated their bone compatibility in vitro and in vivo. Human osteoblasts attachment, proliferation, and osteocalcin expression in non- and HA-coated scaffolds were evaluated. A 10-mm long segmental bone defect in a rabbit mandibular bone was reconstructed with non- or HA-coated scaffolds, which were removed at 9 and 21 weeks, to evaluate the mechanical strength of the bone-scaffold connection and the bone formation around the scaffold. Expression of osteocalcin was greater in HA-coated scaffolds. In vivo bone formation in HA-coated scaffolds was greater than that in non-coated scaffolds at 21 weeks. Newly formed bone in HA-coated scaffolds mostly restored bone continuity. Scanning electron microscopy identified strong integration of the bone and HA-coated scaffolds. The mechanical strength of the bone-scaffold connection was 3-fold greater in HA-coated scaffolds than that in non-coated scaffolds. These results suggest that a thin HA-coated titanium fiber mesh scaffold is a bone-compatible mandibular reconstruction device in immediately loaded segmental defects.

  5. Removal of bone in CT angiography by multiscale matched mask bone elimination

    SciTech Connect

    Gratama van Andel, H. A. F.; Venema, H. W.; Streekstra, G. J.; Straten, M. van; Majoie, C. B. L. M.; Heeten, G. J. den; Grimbergen, C. A.

    2007-10-15

    For clear visualization of vessels in CT angiography (CTA) images of the head and neck using maximum intensity projection (MIP) or volume rendering (VR) bone has to be removed. In the past we presented a fully automatic method to mask the bone [matched mask bone elimination (MMBE)] for this purpose. A drawback is that vessels adjacent to bone may be partly masked as well. We propose a modification, multiscale MMBE, which reduces this problem by using images at two scales: a higher resolution than usual for image processing and a lower resolution to which the processed images are transformed for use in the diagnostic process. A higher in-plane resolution is obtained by the use of a sharper reconstruction kernel. The out-of-plane resolution is improved by deconvolution or by scanning with narrower collimation. The quality of the mask that is used to remove bone is improved by using images at both scales. After masking, the desired resolution for the normal clinical use of the images is obtained by blurring with Gaussian kernels of appropriate widths. Both methods (multiscale and original) were compared in a phantom study and with clinical CTA data sets. With the multiscale approach the width of the strip of soft tissue adjacent to the bone that is masked can be reduced from 1.0 to 0.2 mm without reducing the quality of the bone removal. The clinical examples show that vessels adjacent to bone are less affected and therefore better visible. Images processed with multiscale MMBE have a slightly higher noise level or slightly reduced resolution compared with images processed by the original method and the reconstruction and processing time is also somewhat increased. Nevertheless, multiscale MMBE offers a way to remove bone automatically from CT angiography images without affecting the integrity of the blood vessels. The overall image quality of MIP or VR images is substantially improved relative to images processed with the original MMBE method.

  6. Sequential radionuclide bone imaging in avascular pediatric hip conditions

    SciTech Connect

    Minikel, J.; Sty, J.; Simons, G.

    1983-05-01

    Radionuclide bone imaging was performed on six patients with various hip conditions. Initial bone images revealed diminished uptake of isotope /sup 99m/Tc-MDP in the capital femoral epiphysis. Following therapeutic intervention, repeat bone scans revealed normal uptake of /sup 99m/Tc-MDP in the capital femoral epiphysis. Subsequent radiographs revealed that avascular necrosis had not occurred. There are two types of avascularity: the potentially reversible, and the irreversible. Attempts should be made toward early recognition of the potentially reversible avascular insult. With early recognition, surgical reconstruction prior to osteophyte death may result in revascularization. If this can be accomplished, avascular necrosis can be avoided.

  7. Paget's disease with craniofacial and skeletal bone involvement.

    PubMed

    Rai, Narendra Prakash; Anekar, Jayaprasad; Mustafa, Shabil Mohamed; Devang Divakar, Darshan

    2016-01-01

    Paget's disease is a metabolic disorder of bone caused due to defect in the remodelling process and is very common in western countries but is very rare in Asians and Africans. It was first described by a British scientist Sir James Paget in 1877. It can be monostotic or polyostotic depending on the number of bones involved. It most commonly affects older people of more than 50 years. Disease involvement can be symptomatic or asymptomatic depending on the extent of the disease process. Diagnosis of Paget's disease can be made by raised serum alkaline phosphatase levels, radiological examination and by radioisotope bone scans. PMID:27587747

  8. [Bone fracture and the healing mechanisms. Fragility fracture and bone quality].

    PubMed

    Mawatari, Taro; Iwamoto, Yukihide

    2009-05-01

    Fracture occurs in bone having less than normal elastic resistance without any violence. Numerous terms have been used to classify various types of fractures from low trauma events; "fragility fracture", "stress fracture", "insufficiency fracture", "fatigue fracture", "pathologic fracture", etc. The definitions of these terms and clinical characteristics of these fractures are discussed. Also state-of-the-art bone quality assessments; Finite element analysis of clinical CT scans, assessments of the Microdamage, and the Cross-links of Collagen are introduced in this review.

  9. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice.

    PubMed

    Christiansen, Blaine A

    2016-12-01

    Micro-computed tomography (μCT) is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6-30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV) and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. PMID:27430011

  10. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice.

    PubMed

    Christiansen, Blaine A

    2016-12-01

    Micro-computed tomography (μCT) is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6-30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV) and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals.

  11. [Multifocal epithelioid angiosarcoma of bone with lung metastases].

    PubMed

    Pacheco, C; Albalá, M D; Blanco, M; Hidalgo, F J

    2014-01-01

    Angiosarcoma is a rare mesenchymal neoplasm that may arise from vascular or lymphatic tissue. Bone primary angiosarcoma is extremely rare, representing less than 1% of all angiosarcomas. It́s a very aggressive neoplasm and patients have metastatic disease at initial diagnosis in a large percentage of cases. On radiographs, these lesions are usually aggressive osteolytic lesions, commonly with soft-tissue mass extension, and tumoral enhancement on CT or MR imaging. The appearance of the bone scan is variable, describing studies with tracer uptake or low uptake. These tumours are more often found in the long bones, but spinal involvement has been reported in 10% of patients. There are a few reports in the literature of bone angiosarcoma with lung metastases. We present a patient with multifocal epithelioid angiosarcoma (spine and ribs) and multiple lung metastasis, evidenced by CT and conventional bone scintigraphy, with a fast growth.

  12. Bone mineral measurement using dual energy x ray densitometry

    NASA Technical Reports Server (NTRS)

    Smith, Steven W.

    1989-01-01

    Bone mineral measurements before and after space missions have shown that weightlessness greatly accelerates bone demineralization. Bone mineral losses as high as 1 to 3 percent per month were reported. Highly precise instrumentation is required to monitor this loss and thereby test the efficacy of treatment. During the last year, a significant improvement was made in Dual-Photon Absorptiometry by replacing the radioactive source with an x ray tube. Advantages of this system include: better precision, lower patient dose, better spacial resolution, and shorter scan times. The high precision and low radiation dose of this technique will allow detection of bone mineral changes of less than 1 percent with measurements conducted directly at the sites of interest. This will allow the required bone mineral studies to be completed in a shorter time with greater confidence.

  13. Scan mirrors relay for high resolution laser scanning systems

    NASA Astrophysics Data System (ADS)

    Kessler, David

    2014-09-01

    Two dimensional beam deflection is often required in medical laser scanning systems such as OCT or confocal microscopy. Commonly two linear galvo mirrors are used for performance in terms of their large apertures and scan angles. The galvo mirrors are placed at the vicinity of entrance pupil of the scan lens with a "displacement distance" separating them. This distance limits the scan fields and/or reduces the effective aperture of the scan lens. Another option is to use a beam or pupil relay, and image one galvo mirror onto the other. However, beam (or pupil) relays are notoriously complicated, expensive and can add significant aberrations. This paper discusses a simple, all reflective, diffraction limited, color corrected, beam relay, capable of large scan angles and large deflecting mirrors. The design is based on a unique combination of an Offner configuration with a Schmidt aspheric corrector. The design is highly corrected up to large scan mirrors and large scan angles down to milliwaves of aberrations. It allows significantly larger scan field and or scan lenses with higher numerical aperture as compared with scanners using galvos separated by the displacement distance. While this relay is of exceptionally high performance, it has one element located where the beam is focused which may present a problem for high power lasers. Thus modifications of the above design are introduced where the beam is focused in mid air thus making it usable for high power systems such including laser marking and fabrication systems.

  14. Three-dimensional microarchitecture of adolescent cancellous bone.

    PubMed

    Ding, Ming; Danielsen, Carl Christian; Hvid, Ivan; Overgaard, Søren

    2012-11-01

    This study investigated microarchitectural, mechanical, collagen and mineral properties of normal adolescent cancellous bone, and compared them with adult and aging cancellous bone, to obtain more insight into the subchondral bone adaptations during development and growth. Twenty-three human proximal tibiae were harvested and divided into 3 groups according to their ages: adolescence (9 to 17 years, n=6), young adult (18 to 24 years, n=9), and adult (25 to 30 years, n=8). Twelve cubic cancellous bone samples with dimensions of 8×8×8 mm(3) were produced from each tibia, 6 from each medial and lateral condyle. These samples were micro-CT scanned (vivaCT 40, Scanco Medical AG, Switzerland) resulting in cubic voxel sizes of 10.5*10.5*10.5 μm(3). Microarchitectural properties were calculated. The samples were then tested in compression followed by collagen and mineral determination. Interestingly, the adolescent cancellous bone had similar bone volume fraction (BV/TV), structure type (plate, rod or mixtures), and connectivity (3-D trabecular networks) as the adult cancellous bone. The adolescent cancellous bone had significantly lower bone surface density (bone surface per total volume of specimen) but higher collagen concentration (collagen weight per dry weight of specimen) than the adult cancellous bone; and significant greater trabecular separation (mean distance between trabeculae), significant lower trabecular number (number of trabeculae per volume), tissue density (dry weight per volume of bone matrix excluding marrow space) and mineral concentration (ash weight per dry weight of specimen) than the young adult and adult cancellous bones. Despite these differences, ultimate stress and failure energy were not significantly different among the three groups, only the Young's modulus in anterior-posterior direction was significantly lower in adolescence. Apparent density appears to be the single best predictor of mechanical properties. In conclusion, adolescent

  15. Carboxylation of osteocalcin may be related to bone quality: a possible mechanism of bone fracture prevention by vitamin K.

    PubMed

    Sugiyama, T; Kawai, S

    2001-01-01

    Vitamin K is essential for the carboxylation of glutamic acid residues, such as osteocalcin. Recent studies have reported that vitamin K reduces vertebral and hip fractures without increasing bone mass in patients with osteoporosis, suggesting that vitamin K could affect bone quality. However, the mechanism is unknown. To investigate the involvement of the carboxylation of osteocalcin in bone quality, the present preliminary study examined serum bone markers and ultrasound velocity, a possible indicator of bone quality, in 14 healthy prepubertal children (eight boys and six girls) aged between 7 and 12 years. Venous blood was collected between 0800 and 0900 h after an overnight fast, and serum levels of intact, carboxylated and undercarboxylated osteocalcin, bone-specific alkaline phosphatase and type I procollagen carboxyl extension peptide were measured. Speed of sound in the right tibia was measured using a SoundScan 2000 Compact (Myriad Ultrasound System, Rehovot, Israel). As a result, there was no significant correlation between the serum bone markers and the Z score for the speed of sound. In contrast, the ratio of serum carboxylated osteocalcin to serum intact osteocalcin was positively correlated with the Z score for the speed of sound (r = 0.621, P = 0.016). These findings suggest, for the first time, that carboxylation of osteocalcin is related to bone quality. Further studies are needed to clarify the role of carboxylation of osteocalcin in bone, and this will provide a new insight into the mechanism of vitamin K treatment in osteoporosis. PMID:11368299

  16. Earth observing scanning polarimeter

    NASA Technical Reports Server (NTRS)

    Travis, Larry

    1993-01-01

    Climate forcing by tropospheric aerosols is receiving increased attention because of the realization that the climate effects may be large, while our knowledge of global aerosol characteristics and temporal changes is very poor. Tropospheric aerosols cause a direct radiative forcing due simply to their scattering and absorption of solar radiation, as well as an indirect effect as cloud condensation nuclei which can modify the shortwave reflectivity of clouds. Sulfate aerosols tend to increase planetary albedo through both the direct and indirect effects; a cooling due to anthropogenic sulfate aerosols has been estimated of order 1 W/sq m, noting that this is similar in magnitude to the present anthropogenic greenhouse gas warming. Other aerosols, including those from biomass burning and wind-blown desert dust are also of potential climatic importance. At present, the only global monitoring of tropospheric aerosols is a NOAA operational product, aerosol optical thickness, obtained using channel-1 (0.58-0.68 mu m) radiances from the AVHRR. With this single channel radiance data, one must use an approach which is based on the inferred excess of reflected radiance owing to scattering by the aerosols over that expected from theoretical calculations. This approach is suited only for situations where the surface has a low albedo that is well known a priori. Thus, the NOAA operational product is restricted to coverage over the ocean at AVHRR scan angles well away from sun glint, and aerosol changes are subject to confusion with changes caused by either optically thin or subpixel clouds. Because optically thin aerosols have only a small effect on the radiance, accurate measurements for optical thickness less than 0.1 (which is a typical background level) are precluded. Moreover, some of the largest and most important aerosol changes are expected over land. The Earth Observing Scanning Polarimeter (EOSP) instrument, based upon design heritage and analysis techniques

  17. Study of bone-like hydroxyapatite/polyamino acid composite materials for their biological properties and effects on the reconstruction of long bone defects

    PubMed Central

    Yan, Ling; Jiang, Dian-ming

    2015-01-01

    Purpose The purpose of this study was to investigate the effect of bone-like hydroxyapatite/polyamino acid (BHA/PAA) in the osteogenesis and reconstruction of long segmental bone defects. Methods In vitro, MG63 cells were cultured with BHA/PAA. The osteoinductive activity of the BHA/PAA material was evaluated using inverted microscopy, scanning electron microscopy, MTT proliferation assay, and the determination of alkaline phosphatase activity and Ca2+ content. In vivo, the radial bone defect was made in 20 New Zealand White rabbits, and then these animal were randomly divided into two groups (n=10), the experimental group (with BHA/PAA) and the control group (without BHA/PAA). Postoperatively, the osteogenesis effect of BHA/PAA was evaluated through X-ray, hematoxylin–eosin staining, observation of the gross bone specimen, immunohistochemistry, and fluorescent confocal scanning microscopy. Results In vitro, BHA/PAA promoted the adhesion, growth, and calcium nodule formation of MG63 cells, and it had good osteogenesis activity. In vivo, with BHA/PAA material degradation and absorption, the new bone gradually formed, and the bone defect gradually recovered in the experimental group. In the control group, a limited bone formation was found at the bone broken ends, and the bone defect was obviously visible. Conclusion In vitro and in vivo, we confirmed that BHA/PAA was effective in inducing osteogenesis and reconstructing a long segmental bone defect. PMID:26719675

  18. Does Orthodontic Treatment Affect the Alveolar Bone Density?

    PubMed

    Yu, Jian-Hong; Huang, Heng-Li; Liu, Chien-Feng; Wu, Jay; Li, Yu-Fen; Tsai, Ming-Tzu; Hsu, Jui-Ting

    2016-03-01

    Few studies involving human participants have been conducted to investigate the effect of orthodontic treatment on alveolar bone density around the teeth. Our previous study revealed that patients who received 6 months of active orthodontic treatment exhibited an ∼24% decrease in alveolar bone density around the teeth. However, after an extensive retention period following orthodontic treatment, whether the bone density around the teeth can recover to its original state from before the treatment remains unclear, thus warranting further investigation.The purpose of this study was to assess the bone density changes around the teeth before, during, and after orthodontic treatment.Dental cone-beam computed tomography (CBCT) was used to measure the changes in bone density around 6 teeth in the anterior maxilla (maxilla central incisors, lateral incisors, and canines) of 8 patients before and after orthodontic treatment. Each patient underwent 3 dental CBCT scans: before treatment (T0); at the end of 7 months of active orthodontic treatment (T1); after several months (20-22 months) of retention (T2). The Friedman test was applied to evaluate the changes in the alveolar bone density around the teeth according to the 3 dental CBCT scans.From T0 to T1, a significant reduction in bone density was observed around the teeth (23.36 ± 10.33%); by contrast, a significant increase was observed from T1 to T2 (31.81 ± 23.80%). From the perspective of the overall orthodontic treatment, comparing the T0 and T2 scans revealed that the bone density around the teeth was relatively constant (a reduction of only 0.75 ± 19.85%). The results of the statistical test also confirmed that the difference in bone density between T0 and T2 was nonsignificant.During orthodontic tooth movement, the alveolar bone density around the teeth was reduced. However, after a period of bone recovery, the reduced bone density recovered to its previous state from before the orthodontic treatment

  19. Does Orthodontic Treatment Affect the Alveolar Bone Density?

    PubMed Central

    Yu, Jian-Hong; Huang, Heng-Li; Liu, Chien-Feng; Wu, Jay; Li, Yu-Fen; Tsai, Ming-Tzu; Hsu, Jui-Ting

    2016-01-01

    Abstract Few studies involving human participants have been conducted to investigate the effect of orthodontic treatment on alveolar bone density around the teeth. Our previous study revealed that patients who received 6 months of active orthodontic treatment exhibited an ∼24% decrease in alveolar bone density around the teeth. However, after an extensive retention period following orthodontic treatment, whether the bone density around the teeth can recover to its original state from before the treatment remains unclear, thus warranting further investigation. The purpose of this study was to assess the bone density changes around the teeth before, during, and after orthodontic treatment. Dental cone-beam computed tomography (CBCT) was used to measure the changes in bone density around 6 teeth in the anterior maxilla (maxilla central incisors, lateral incisors, and canines) of 8 patients before and after orthodontic treatment. Each patient underwent 3 dental CBCT scans: before treatment (T0); at the end of 7 months of active orthodontic treatment (T1); after several months (20–22 months) of retention (T2). The Friedman test was applied to evaluate the changes in the alveolar bone density around the teeth according to the 3 dental CBCT scans. From T0 to T1, a significant reduction in bone density was observed around the teeth (23.36 ± 10.33%); by contrast, a significant increase was observed from T1 to T2 (31.81 ± 23.80%). From the perspective of the overall orthodontic treatment, comparing the T0 and T2 scans revealed that the bone density around the teeth was relatively constant (a reduction of only 0.75 ± 19.85%). The results of the statistical test also confirmed that the difference in bone density between T0 and T2 was nonsignificant. During orthodontic tooth movement, the alveolar bone density around the teeth was reduced. However, after a period of bone recovery, the reduced bone density recovered to its previous state from before the

  20. LANL Robotic Vessel Scanning

    SciTech Connect

    Webber, Nels W.

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  1. GPR scan assessment

    NASA Astrophysics Data System (ADS)

    Abbas, Abbas M.; Salah, Hany; Massoud, Usama; Fouad, Mona; Abdel-Hafez, Mahmoud

    2015-06-01

    Mekaad Radwan monument is situated in the neighborhood of Bab Zuweila in the historical Cairo, Egypt. It was constructed at the middle XVII century (1635 AD). The building has a rectangle shape plan (13 × 6 m) with the longitudinal sides approximately WNW-ESE. It comprises three storages namely; the ground floor; the opened floor (RADWAN Bench) and the living floor with a total elevation of 15 m above the street level. The building suffers from severe deterioration phenomena with patterns of damage which have occurred over time. These deterioration and damages could be attributed to foundation problems, subsoil water and also to the earthquake that affected the entire Greater Cairo area in October 1992. Ground Penetrating Radar (GPR) scan was accomplished against the walls of the opened floor (RADWAN Bench) to evaluate the hazard impact on the walls textures and integrity. The results showed an anomalous feature through the southern wall of RADWAN Bench. A mathematical model has been simulated to confirm the obtained anomaly and the model response exhibited a good matching with the outlined anomaly.

  2. Laser Scanning Cytometry

    PubMed Central

    Pozarowski, Piotr; Holden, Elena; Darzynkiewicz, Zbigniew

    2013-01-01

    Summary The laser scanning cytometer (LSC) is the microscope-based cytofluorometer that offers a plethora of analytical capabilities. Multilaser-excited fluorescence emitted from individual cells is measured at several wavelength ranges, rapidly (up to 5000 cells/min), with high sensitivity and accuracy. The following applications of LSC are reviewed: (1) identification of cells that differ in degree of chromatin condensation (e.g., mitotic or apoptotic cells or lymphocytes vs granulocytes vs monocytes); (2) detection of translocation between cytoplasm vs nucleus or nucleoplasm vs nucleolus of regulatory molecules such as NF- κB, p53, or Bax; (3) semiautomatic scoring of micronuclei in mutagenicity assays; (4) analysis of fluorescence in situ hybridization; (5) enumeration and morphometry of nucleoli; (6) analysis of phenotype of progeny of individual cells in clonogenicity assay; (7) cell immunophenotyping; (8) visual examination, imaging, or sequential analysis of the cells measured earlier upon their relocation, using different probes; (9) in situ enzyme kinetics and other time-resolved processes; (10) analysis of tissue section architecture; (11) application for hypocellular samples (needle aspirate, spinal fluid, etc.); (12) other clinical applications. Advantages and limitations of LSC are discussed and compared with flow cytometry. PMID:16719355

  3. Determination of Small Animal Long Bone Properties Using Densitometry

    NASA Technical Reports Server (NTRS)

    Breit, Gregory A.; Goldberg, BethAnn K.; Whalen, Robert T.; Hargens, Alan R. (Technical Monitor)

    1996-01-01

    Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased

  4. Computed tomography and bone scintigraphy is polyostotic fibrous dysplasia. Report of a case. [Tc 99m

    SciTech Connect

    Higashi, T.; Iguchi, M.; Shimura, A.; Kruglik, G.D.

    1980-12-01

    A case of polyostotic fibrous dysplasia is presented in which the extent of bony lesions was defined on the results of the CT scan and bone scan with 99m Tc polyphosphate in addition to conventional radiography. These diagnostic procedures appear to be of considerable value in defining the extent of a variety of oral-maxillofacial bony lesions. This report describes the comparative findings from 99m Tc polyphosphate bone imaging and computed tomography (CT) in one patient with polyostotic fibrous dysplasia.

  5. Detection of degenerative disease of the temporomandibular joint by bone scintigraphy: concise communication

    SciTech Connect

    Goldstein, H.A.; Bloom, C.Y.

    1980-10-01

    Nine patients with facial pain were evaluated with limited bone scans. The scintigrams correlated with microscopy in all patients, although radiographs correlated with microscopy in only five patients. The degenerative disease process in the temporomandibular joint was more extensive in the patients with radiographic and scintigraphic abnormalities than in those with scintigraphic abnormalities alone. The limited bone scan appears useful in detecting early degenerative changes in the temporomandibular joint.

  6. Spontaneous Bone Healing after Cysts Enucleation without Bone Grafting Materials: A Randomized Clinical Study

    PubMed Central

    Rubio, Eduardo Daniel; Mombrú, Carlos Mariano

    2014-01-01

    The aim of this study was to evaluate spontaneous bone regeneration after cysts enucleation of the jaws without the use of bone grafting materials. We included 18 patients at random (11 men and 7 women) with a mean age of 31.8 years, with jaw cysts treated by enucleation, without the use of grafting materials. A method of measurements to assess the percentage of reduction of the bone cavities was used to objectify the results. The patients were evaluated before and at least 6 months after surgery, with radiographic scans based on linear measures with a computerized method using Nemoceph program (Nemotec, NemoCeph Software, Madrid, España). The analysis of the sample shows an average of 85.59% decrease in horizontal measures, 89.53% in the vertical, and 88.98 and 89.81% in the diagonal left and right, respectively. The total average reduction was 88.47%. It showed a greater decrease in vertical and diagonal measurements with respect to horizontal. Regeneration in 12 patients was 100% and in 6 patients was higher at 50.4%. Bone density increased in the postoperative radiographs. The results suggest that in some cases, spontaneous bone regeneration can be achieved by cysts enucleation without bone grafting materials. PMID:25709749

  7. Composition analysis by scanning femtosecond laser ultraprobing (CASFLU).

    DOEpatents

    Ishikawa, Muriel Y.; Wood, Lowell L.; Campbell, E. Michael; Stuart, Brent C.; Perry, Michael D.

    2002-01-01

    The composition analysis by scanning femtosecond ultraprobing (CASFLU) technology scans a focused train of extremely short-duration, very intense laser pulses across a sample. The partially-ionized plasma ablated by each pulse is spectrometrically analyzed in real time, determining the ablated material's composition. The steering of the scanned beam thus is computer directed to either continue ablative material-removal at the same site or to successively remove nearby material for the same type of composition analysis. This invention has utility in high-speed chemical-elemental, molecular-fragment and isotopic analyses of the microstructure composition of complex objects, e.g., the oxygen isotopic compositions of large populations of single osteons in bone.

  8. Biophotonics and Bone Biology

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory; Fischer, David; Asipauskas, Marius; Chauhan, Chirag; Compitello, Nicole; Burke, Jamie; Tate, Melissa Knothe

    2004-01-01

    One of the more-serious side effects of extended space flight is an accelerated bone loss [Bioastronautics Critical Path Roadmap, http://research.hq.nasa.gov/code_u/bcpr/index.cfm]. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It shows that an extrapolation of the microgravity induced bone loss rates to longer time scales, such as a 2.5 year round-trip to Mars (6 months out at 0 g, 1.5 year stay on Mars at 0.38 g, 6 months back at 0 g), could severely compromise the skeletal system of such a person.

  9. Biomaterials and bone mechanotransduction

    NASA Technical Reports Server (NTRS)

    Sikavitsas, V. I.; Temenoff, J. S.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)

    2001-01-01

    Bone is an extremely complex tissue that provides many essential functions in the body. Bone tissue engineering holds great promise in providing strategies that will result in complete regeneration of bone and restoration of its function. Currently, such strategies include the transplantation of highly porous scaffolds seeded with cells. Prior to transplantation the seeded cells are cultured in vitro in order for the cells to proliferate, differentiate and generate extracellular matrix. Factors that can affect cellular function include the cell-biomaterial interaction, as well as the biochemical and the mechanical environment. To optimize culture conditions, good understanding of these parameters is necessary. The new developments in bone biology, bone cell mechanotransduction, and cell-surface interactions are reviewed here to demonstrate that bone mechanotransduction is strongly influenced by the biomaterial properties.

  10. [Evaluation of multiple myeloma with bone scintigraphy using Tc 99 diphosphonate. Review of the literature].

    PubMed

    Solis, O J; Gonzales, R; De Luca, S; McKusick, K A; Potsaid, M S

    1977-04-01

    Bone Scanning using 99m Tc-Diphosphonate is another diagnostic modality in the evaluation of multiple mieloma which allows the identification of bone lesions not demonstrable by conventional radiography. The use of 99m Tc-Diphosphonate is more convenient and less harmful than other radioactive isotopes utilized before. PMID:866897

  11. Acute lymphocytic leukemia presented as back pain and revealed by bone scintigraphy.

    PubMed

    Liu, Bin; Gwal, Kriti; Servaes, Sabah; Zhuang, Hongming

    2013-08-01

    A previously healthy 8-year-old girl underwent MDP bone scintigraphy to evaluate possible spondylolysis due to worsening back pain. Unexpectedly, the bone scan images revealed intense activity in several thoracic and lumbar vertebrae, which was not consistent with spondylolysis. Further examinations proved that the patient had acute lymphocytic leukemia.

  12. Effects of acepromazine on three-phase 99mTc-MDP bone imaging in 11 horses.

    PubMed

    Solano, Mauricio; Welcome, Jeremy; Johnson, Karen

    2005-01-01

    Horses undergoing skeletal scintigraphy can have decreased radiopharmaceutical bone uptake in the limbs. This reduces the diagnostic value of the scan. The aim of the present study was to measure the changes in count density caused by vasodilatation and increased blood flow associated with intravenous injection of acepromazine during bone scintigraphy in normal horses. A three-phase bone scan was performed twice in 11 adult horses to study the effects of acepromazine on the count density of the resultant scintigrams. With acepromazine, there was a statistically significant mean difference of 12 s for initial blood flow and 21 s for peak flow. The time to initial blood flow and time to peak flow occurred earlier for the scans in which acepromazine was used. There were no significant differences in the bone to soft tissue ratios during the soft tissue and bone phases of the scan between procedures. Intravenous administration of acepromazine increases peripheral blood flow causing an earlier onset of the vascular phase during the three-phase bone scan. Acepromazine did not increase the count density of the bone phase scintigrams. As expected, the vasodilatation and increased blood flow associated with intravenous injection of acepromazine affected the count density of the vascular phase of the bone scan.

  13. Stochastic scanning multiphoton multifocal microscopy.

    PubMed

    Jureller, Justin E; Kim, Hee Y; Scherer, Norbert F

    2006-04-17

    Multiparticle tracking with scanning confocal and multiphoton fluorescence imaging is increasingly important for elucidating biological function, as in the transport of intracellular cargo-carrying vesicles. We demonstrate a simple rapid-sampling stochastic scanning multifocal multiphoton microscopy (SS-MMM) fluorescence imaging technique that enables multiparticle tracking without specialized hardware at rates 1,000 times greater than conventional single point raster scanning. Stochastic scanning of a diffractive optic generated 10x10 hexagonal array of foci with a white noise driven galvanometer yields a scan pattern that is random yet space-filling. SS-MMM creates a more uniformly sampled image with fewer spatio-temporal artifacts than obtained by conventional or multibeam raster scanning. SS-MMM is verified by simulation and experimentally demonstrated by tracking microsphere diffusion in solution. PMID:19516485

  14. Nanocomposites and bone regeneration

    NASA Astrophysics Data System (ADS)

    James, Roshan; Deng, Meng; Laurencin, Cato T.; Kumbar, Sangamesh G.

    2011-12-01

    This manuscript focuses on bone repair/regeneration using tissue engineering strategies, and highlights nanobiotechnology developments leading to novel nanocomposite systems. About 6.5 million fractures occur annually in USA, and about 550,000 of these individual cases required the application of a bone graft. Autogenous and allogenous bone have been most widely used for bone graft based therapies; however, there are significant problems such as donor shortage and risk of infection. Alternatives using synthetic and natural biomaterials have been developed, and some are commercially available for clinical applications requiring bone grafts. However, it remains a great challenge to design an ideal synthetic graft that very closely mimics the bone tissue structurally, and can modulate the desired function in osteoblast and progenitor cell populations. Nanobiomaterials, specifically nanocomposites composed of hydroxyapatite (HA) and/or collagen are extremely promising graft substitutes. The biocomposites can be fabricated to mimic the material composition of native bone tissue, and additionally, when using nano-HA (reduced grain size), one mimics the structural arrangement of native bone. A good understanding of bone biology and structure is critical to development of bone mimicking graft substitutes. HA and collagen exhibit excellent osteoconductive properties which can further modulate the regenerative/healing process following fracture injury. Combining with other polymeric biomaterials will reinforce the mechanical properties thus making the novel nano-HA based composites comparable to human bone. We report on recent studies using nanocomposites that have been fabricated as particles and nanofibers for regeneration of segmental bone defects. The research in nanocomposites, highlight a pivotal role in the future development of an ideal orthopaedic implant device, however further significant advancements are necessary to achieve clinical use.

  15. Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study

    PubMed Central

    He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu

    2015-01-01

    The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold. PMID:26380018

  16. Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study.

    PubMed

    He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu

    2015-01-01

    The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold.

  17. The history of cerebral PET scanning

    PubMed Central

    Portnow, Leah H.; Vaillancourt, David E.; Okun, Michael S.

    2013-01-01

    Objective: To review the discoveries underpinning the introduction of cerebral PET scanning and highlight its modern applications. Background: Important discoveries in neurophysiology, brain metabolism, and radiotracer development in the post–World War II period provided the necessary infrastructure for the first cerebral PET scan. Methods: A complete review of the literature was undertaken to search for primary and secondary sources on the history of PET imaging. Searches were performed in PubMed, Google Scholar, and select individual journal Web sites. Written autobiographies were obtained through the Society for Neuroscience Web site at www.sfn.org. A reference book on the history of radiology, Naked to the Bone, was reviewed to corroborate facts and to locate references. The references listed in all the articles and books obtained were reviewed. Results: The neurophysiologic sciences required to build cerebral PET imaging date back to 1878. The last 60 years have produced an evolution of technological advancements in brain metabolism and radiotracer development. These advancements facilitated the development of modern cerebral PET imaging. Several key scientists were involved in critical discoveries and among them were Angelo Mosso, Charles Roy, Charles Sherrington, John Fulton, Seymour Kety, Louis Sokoloff, David E. Kuhl, Gordon L. Brownell, Michael Ter-Pogossian, Michael Phelps, and Edward Hoffman. Conclusions: Neurophysiology, metabolism, and radiotracer development in the postwar era synergized the development of the technology necessary for cerebral PET scanning. Continued use of PET in clinical trials and current developments in PET-CT/MRI hybrids has led to advancement in diagnosis, management, and treatment of neurologic disorders. PMID:23460618

  18. A female pelvic bone shape model for air/bone separation in support of synthetic CT generation for radiation therapy

    NASA Astrophysics Data System (ADS)

    Liu, Lianli; Cao, Yue; Fessler, Jeffrey A.; Jolly, Shruti; Balter, James M.

    2016-01-01

    Separating bone from air in MR data is one of the major challenges in using MR images to derive synthetic CT. The problem is further complicated when the anatomic regions filled with air are altered across scans due to air mobility, for instance, in pelvic regions, thereby the air regions estimated using an ultrashort echo time (UTE) sequence are invalid in other image series acquired for multispectral classification. This study aims to develop and investigate a female pelvic bone shape model to identify low intensity regions in MRI where air is unlikely to be present in support of synthetic CT generation without UTE imaging. CT scans of 30 patients were collected for the study, 17 of them also have corresponding MR scans. The shape model was built from the CT dataset, where the reference image was aligned to each of the training images using B-spline deformable registration. Principal component analysis was performed on B-spline coefficients for a compact model where shape variance was described by linear combination of principal modes. The model was applied to identify pelvic bone in MR images by deforming the corresponding MR data of the reference image to target MR images, where the search space of the deformation process was constrained within the subspace spanned by principal modes. The local minima in the search space were removed effectively by the shape model, thus supporting an efficient binary search for the optimal solution. We evaluated the model by its efficacy in identifying bone voxels and excluding air regions. The model was tested across the 17 patients that have corresponding MR scans using a leave-one-out cross validation. A simple model using the first leading principal mode only was found to achieve reasonable accuracy, where an averaged 87% of bone voxels were correctly identified. Finally dilation of the optimally fit bone mask by 5 mm was found to cover 96% of bone voxels while minimally impacting the overlap with air (below 0.4%).

  19. Biophotonics and Bone Biology

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory; Fischer, David; Asipauskas, Marius; Chauhan, Chirag; Compitello, Nicole; Burke, Jamie; Tate, Melissa Knothe

    2004-01-01

    One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

  20. Method for fusing bone

    DOEpatents

    Mourant, J.R.; Anderson, G.D.; Bigio, I.J.; Johnson, T.M.

    1996-03-12

    The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  1. Genetics of aging bone.

    PubMed

    Adams, Douglas J; Rowe, David W; Ackert-Bicknell, Cheryl L

    2016-08-01

    With aging, the skeleton experiences a number of changes, which include reductions in mass and changes in matrix composition, leading to fragility and ultimately an increase of fracture risk. A number of aspects of bone physiology are controlled by genetic factors, including peak bone mass, bone shape, and composition; however, forward genetic studies in humans have largely concentrated on clinically available measures such as bone mineral density (BMD). Forward genetic studies in rodents have also heavily focused on BMD; however, investigations of direct measures of bone strength, size, and shape have also been conducted. Overwhelmingly, these studies of the genetics of bone strength have identified loci that modulate strength via influencing bone size, and may not impact the matrix material properties of bone. Many of the rodent forward genetic studies lacked sufficient mapping resolution for candidate gene identification; however, newer studies using genetic mapping populations such as Advanced Intercrosses and the Collaborative Cross appear to have overcome this issue and show promise for future studies. The majority of the genetic mapping studies conducted to date have focused on younger animals and thus an understanding of the genetic control of age-related bone loss represents a key gap in knowledge.

  2. Autoinflammatory bone diseases.

    PubMed

    Stern, Sara M; Ferguson, Polly J

    2013-11-01

    Autoinflammatory bone disease is a new branch of autoinflammatory diseases caused by seemingly unprovoked activation of the innate immune system leading to an osseous inflammatory process. The inflammatory bone lesions in these disorders are characterized by chronic inflammation that is typically culture negative with no demonstrable organism on histopathology. The most common autoinflammatory bone diseases in childhood include chronic nonbacterial osteomyelitis (CNO), synovitis, acne, pustulosis, hyperostosis, osteitis syndrome, Majeed syndrome, deficiency of interleukin-1 receptor antagonist, and cherubism. In this article, the authors focus on CNO and summarize the distinct genetic autoinflammatory bone syndromes.

  3. A technique for developing CAD geometry of long bones using clinical CT data.

    PubMed

    Davis, Matthew L; Vavalle, Nicholas A; Stitzel, Joel D; Gayzik, F Scott

    2015-11-01

    Computed tomography scans are a valuable tool for developing computational models of bones. The objective of this study is to present a method to generate CAD representations of long bones from clinically based CT scans. A secondary aim is to apply the method to six long bones from a sample of three individuals. Periosteal and endosteal bone surfaces were segmented and used to calculate the characteristic cortical thickness, Tc, at 1 mm increments along the bone axis. In the epiphyses where the value of Tc fell below the scanner threshold, the endosteal bone layer was replaced using literature values projected inward from the periosteal surface. On average, 74.7 ± 7.4% of the bone geometry was above the scanner cut-off and was therefore derived from the CT scan data. The thickness measurement was also compared to experimental measurements of cadaveric bone and was found to predict Tc with an error of 3.1%. This method presents a possible solution for the characterization of characteristic thickness along the length of the bone and may also aid in the development of orthopedic implant design and subject specific finite element models.

  4. Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning

    NASA Technical Reports Server (NTRS)

    Charles, Jr., Harry K. (Inventor); Beck, Thomas J. (Inventor); Feldmesser, Howard S. (Inventor); Magee, Thomas C. (Inventor)

    2007-01-01

    Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.

  5. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects.

    PubMed

    Van der Stok, Johan; Van der Jagt, Olav P; Amin Yavari, Saber; De Haas, Mirthe F P; Waarsing, Jan H; Jahr, Holger; Van Lieshout, Esther M M; Patka, Peter; Verhaar, Jan A N; Zadpoor, Amir A; Weinans, Harrie

    2013-05-01

    Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120-µm (titanium-120) or 230-µm (titanium-230) were studied in a load-bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium-120, titanium-230, or left empty. In vivo micro-CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm(3) (titanium-120, p = 0.015) and 18.7 ± 8.0 mm(3) (titanium-230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm(3) ). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium-120) and 45% (titanium-230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects.

  6. Final Report: Bone Mass Inheritance: A Project to Identify the Genetic Regulation of Bone Mass

    SciTech Connect

    Recker, Robert R., M.D.

    2002-03-28

    This project was designed to find human chromosomal locations that contain genes regulating peak bone density. It is part of a whole genome search for those loci,each responsible for at least 15% of the variation in the peak adult bone density. We accomplished this with a sib pair design, combined with simultaneous examination of extended kindreds. This project gave partial support of the recruitment which has now been completed. The project will extend into 2003. During the remainder of the project, a whole genome scan will be performed from the entire cohort of 2226 persons who have DNA archived, followed by linkage analysis. This project will meet the scientific objective leading eventually to expanded options for treating the condition that leads to bone thinning osteoporosis, and potential fractures in aging populations.

  7. Utility of Computed Tomography Scans in Predicting Need for Surgery in Nasal Injuries

    PubMed Central

    Peterson, Benjamin E.; Doerr, Timothy D.

    2013-01-01

    In many centers, computed tomography (CT) scan is preferred over plain film radiographs in the setting of acute nasal injury because CT scan is thought to be more sensitive in predicting nasal bone fracture. However, the usefulness of CT scans in predicting the need for surgery in acute nasal injury has not been well-studied. We conducted a retrospective review of 232 patients with known nasal bone fracture and found very similar rates of surgery in patients with a diagnosis of nasal fracture by CT scan as by nasal radiographs (41 and 37%, respectively). This suggests that experienced clinical examination remains the gold standard for determining the need for surgery in isolated nasal trauma, regardless of CT findings. PMID:24436764

  8. Aneurysmal bone cyst involving the metacarpal bone in a child.

    PubMed

    Song, Kwang Soon; Lee, Si Wook; Bae, Ki Cheor; Sohn, Eun Seok

    2015-03-01

    Aneurysmal bone cysts associated with tubular bones of the hand occur rarely and require particular diagnostic and therapeutic management techniques. While optimal treatment has not been established, accepted treatments range from aggressive radical treatment, including en bloc resection and excision diaphysectomy with strut bone grafting, to relatively simple techniques, such as thorough curettage followed by bone graft. Aggressive treatment approaches may be optimal for the cases with articular surface involvement, full-bone invasion of the phalanx or metacarpal, or more than 1 recurrence. We report a monocentric case of aneurysmal bone cysts involving metacarpal bone in a child who achieved favorable outcome with curettage and morselized cancellous bone grafts. PMID:25750953

  9. THE IMMUNE SYSTEM AND BONE

    PubMed Central

    Pacifici, Roberto

    2010-01-01

    T cells and B cells produce large amounts of cytokines which regulate bone resorption and bone formation. These factors play a critical role in the regulation of bone turnover in health and disease. In addition, immune cells of the bone marrow regulate bone homeostasis by cross-talking with bone marrow stromal cells and osteoblastic cells via cell surface molecules. These regulatory mechanisms are particularly relevant for postmenopausal osteoporosis and hyperparathyroidism, two common forms of bone loss caused primarily by an expansion of the osteoclastic pool only partially compensated by a stimulation of bone formation. This article describes the cytokines and immune factors that regulate bone cells, the immune cells relevant to bone, examines the connection between T cells and bone in health and disease, and reviews the evidence in favor of a link between T cells and the mechanism of action of estrogen and PTH in bone. PMID:20599675

  10. Oral Health and Bone Disease

    MedlinePlus

    ... Healthy Bones Resources For Your Information Skeletal Bone Density and Dental Concerns The portion of the jawbone ... who do not have the disease. Low bone density in the jaw can result in other dental ...

  11. Bone Grafting the Cleft Maxilla

    MedlinePlus

    ... amount of bone from one place (usually the hip, head, ribs, or leg) and placing it in ... adjacent teeth into the bone graft; 2) prosthetic replacement (dental bridge); or 3) dental metallic bone implants. ...

  12. Exercise for Your Bone Health

    MedlinePlus

    ... supported by your browser. Home Bone Basics Lifestyle Exercise for Your Bone Health Publication available in: PDF ( ... A Complete Osteoporosis Program For Your Information Why Exercise? Like muscle, bone is living tissue that responds ...

  13. Nuclear Medicine Scans for Cancer

    MedlinePlus

    ... are the possible complications? For the most part, nuclear scans are safe tests. The doses of radiation are very small, and the radionuclides have a ... else should I know about these tests? The radiation exposure from a nuclear scan comes from the radionuclides used – the scanner ...

  14. Coating with a Modular Bone Morphogenetic Peptide Promotes Healing of a Bone-Implant Gap in an Ovine Model

    PubMed Central

    Lu, Yan; Lee, Jae Sung; Nemke, Brett; Graf, Ben K.; Royalty, Kevin; Illgen, Richard; Vanderby, Ray; Markel, Mark D.; Murphy, William L.

    2012-01-01

    Despite the potential for growth factor delivery strategies to promote orthopedic implant healing, there is a need for growth factor delivery methods that are controllable and amenable to clinical translation. We have developed a modular bone growth factor, herein termed “modular bone morphogenetic peptide (mBMP)”, which was designed to efficiently bind to the surface of orthopedic implants and also stimulate new bone formation. The purpose of this study was to coat a hydroxyapatite-titanium implant with mBMP and evaluate bone healing across a bone-implant gap in the sheep femoral condyle. The mBMP molecules efficiently bound to a hydroxyapatite-titanium implant and 64% of the initially bound mBMP molecules were released in a sustained manner over 28 days. The results demonstrated that the mBMP-coated implant group had significantly more mineralized bone filling in the implant-bone gap than the control group in C-arm computed tomography (DynaCT) scanning (25% more), histological (35% more) and microradiographic images (50% more). Push-out stiffness of the mBMP group was nearly 40% greater than that of control group whereas peak force did not show a significant difference. The results of this study demonstrated that mBMP coated on a hydroxyapatite-titanium implant stimulates new bone formation and may be useful to improve implant fixation in total joint arthroplasty applications. PMID:23185610

  15. PHYSICOCHEMICAL CHARACTERIZATION OF LYOPHILIZED BOVINE BONE GRAFTS

    PubMed Central

    Galia, Carlos Roberto; Lourenço, André Luis; Rosito, Ricardo; Souza Macedo, Carlos Alberto; Camargo, Lourdes Maria Araujo Quaresma

    2015-01-01

    To evaluate the physicochemical characteristics of lyophilized bovine grafts manufactured on a semi-industrial scale (Orthogen; Baumer S/A*) in accordance with a protocol previously developed by the authors. Methods: The lyophilized bovine bone grafts were characterized by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffractometry (XRD), thermogravimetric (TG) analysis, differential exploratory scanning calorimetry (DSC) and Fourier-transform infrared (FT-IR) spectroscopy. Results: Ca was the main component (60%) found in the samples, followed by P (28%) and O (5%). The mean (sd) pore size was 316 μm (146.7), ranging from 91.2 to 497.8 μm, and 333.5 μm (304.8), ranging from 87.2 to 963.9 μm, at 50x and 150x magnification, respectively. The hydroxyapatite peaks were at 26°C and 32°C, and mass losses were observed between 250°C and 640°C, corresponding to organic material and water. Two temperature transitions (45.67°C and 91.89°C) showed denaturation of type 1 collagen and dehydration of hydroxyapatite. Conclusion: The physicochemical assessment of lyophilized bovine bone grafts in accordance with the protocol developed at semi-industrial scale confirmed that this product presents excellent biocompatibility, with characteristics similar to natural bone. PMID:27027036

  16. Automated trabecular bone histomorphometry

    NASA Technical Reports Server (NTRS)

    Polig, E.; Jee, W. S. S.

    1985-01-01

    The toxicity of alpha-emitting bone-seeking radionuclides and the relationship between bone tumor incidence and the local dosimetry of radionuclides in bone are investigated. The microdistributions of alpha-emitting radionuclides in the trabecular bone from the proximal humerus, distal humerus, proximal ulna, proximal femur, and distal femur of six young adult beagles injected with Am-241 (three with 2.8 micro-Ci/kg and three with 0.9 micro-Ci/kg) are estimated using a computer-controlled microscope photometer system; the components of the University of Utah Optical Track Scanner are described. The morphometric parameters for the beagles are calculated and analyzed. It is observed that the beagles injected with 0.9 micro-Ci of Am-241/kg showed an increase in the percentage of bone and trabecular bone thickness, and a reduction in the width of the bone marrow space and surface/volume ratio. The data reveal that radiation damage causes abnormal bone structure.

  17. Surgery for Bone Cancer

    MedlinePlus

    ... heat. The heat helps kill any remaining tumor cells. This allows PMMA to be used without cryosurgery for some types of bone tumors. Surgical treatment of metastasis To be able to cure a bone cancer, it and any existing metastases must be removed ...

  18. Osteotransductive bone cements.

    PubMed

    Driessens, F C; Planell, J A; Boltong, M G; Khairoun, I; Ginebra, M P

    1998-01-01

    Calcium phosphate bone cements (CPBCs) are osteotransductive, i.e. after implantation in bone they are transformed into new bone tissue. Furthermore, due to the fact that they are mouldable, their osteointegration is immediate. Their chemistry has been established previously. Some CPBCs contain amorphous calcium phosphate (ACP) and set by a sol-gel transition. The others are crystalline and can give as the reaction product dicalcium phosphate dihydrate (DCPD), calcium-deficient hydroxyapatite (CDHA), carbonated apatite (CA) or hydroxyapatite (HA). Mixed-type gypsum-DCPD cements are also described. In vivo rates of osteotransduction vary as follows: gypsum-DCPD > DCPD > CDHA approximately CA > HA. The osteotransduction of CDHA-type cements may be increased by adding dicalcium phosphate anhydrous (DCP) and/or CaCO3 to the cement powder. CPBCs can be used for healing of bone defects, bone augmentation and bone reconstruction. Incorporation of drugs like antibiotics and bone morphogenetic protein is envisaged. Load-bearing applications are allowed for CHDA-type, CA-type and HA-type CPBCs as they have a higher compressive strength than human trabecular bone (10 MPa).

  19. Benign bone tumors.

    PubMed

    Steffner, Robert

    2014-01-01

    Benign bone lesions are a broad category that demonstrates a spectrum of activities from latent to aggressive. Differentiating the various tumors is important in order to properly determine necessary intervention. This chapter focuses on the presentation, imaging, diagnostic features, and treatment of the most common benign bone tumors in order to help guide diagnosis and management. PMID:25070230

  20. Biodegradable synthetic bone composites

    DOEpatents

    Liu, Gao; Zhao, Dacheng; Saiz, Eduardo; Tomsia, Antoni P.

    2013-01-01

    The invention provides for a biodegradable synthetic bone composition comprising a biodegradable hydrogel polymer scaffold comprising a plurality of hydrolytically unstable linkages, and an inorganic component; such as a biodegradable poly(hydroxyethylmethacrylate)/hydroxyapatite (pHEMA/HA) hydrogel composite possessing mineral content approximately that of human bone.

  1. BONES, TEACHER'S GUIDE.

    ERIC Educational Resources Information Center

    Elementary Science Study, Newton, MA.

    THIS GUIDE WAS DEVELOPED FOR USE WITH THE ELEMENTARY SCIENCE STUDY UNIT ON "BONES.""BONES" HAS BEEN TAUGHT IN THE FOURTH GRADE AND REQUIRES FROM 10 TO 25 LESSONS, DEPENDING ON THE NUMBER OF ACTIVITIES USED. THE GUIDE DOES NOT PROVIDE DETAILED INSTRUCTION FOR CONDUCTING CLASSES, BUT RATHER SOME POSSIBLE ACTIVITIES, AND LEAVES THE DAY-TO-DAY…

  2. An interchangeable scanning Hall probe/scanning SQUID microscope

    SciTech Connect

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  3. An interchangeable scanning Hall probe/scanning SQUID microscope.

    PubMed

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M J; Ling, D C; Chi, C C; Chen, Jeng-Chung

    2014-08-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10(-7) T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La(2/3)Ca(1/3)MnO3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K. PMID:25173276

  4. An interchangeable scanning Hall probe/scanning SQUID microscope.

    PubMed

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M J; Ling, D C; Chi, C C; Chen, Jeng-Chung

    2014-08-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10(-7) T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La(2/3)Ca(1/3)MnO3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  5. Large aperture scanning airborne lidar

    NASA Technical Reports Server (NTRS)

    Smith, J.; Bindschadler, R.; Boers, R.; Bufton, J. L.; Clem, D.; Garvin, J.; Melfi, S. H.

    1988-01-01

    A large aperture scanning airborne lidar facility is being developed to provide important new capabilities for airborne lidar sensor systems. The proposed scanning mechanism allows for a large aperture telescope (25 in. diameter) in front of an elliptical flat (25 x 36 in.) turning mirror positioned at a 45 degree angle with respect to the telescope optical axis. The lidar scanning capability will provide opportunities for acquiring new data sets for atmospheric, earth resources, and oceans communities. This completed facility will also make available the opportunity to acquire simulated EOS lidar data on a near global basis. The design and construction of this unique scanning mechanism presents exciting technological challenges of maintaining the turning mirror optical flatness during scanning while exposed to extreme temperatures, ambient pressures, aircraft vibrations, etc.

  6. The experimental and numerical study of indirect effect of a rifle bullet on the bone.

    PubMed

    Zhang, Xiaoyun; Xu, Cheng; Wen, Yaoke; Luo, Shaomin

    2015-12-01

    We study the transient indirect effect of a rifle bullet on bone in the gelatin-bone composite target experimentally and computationally. The process of a 56 type 7.62-mm rifle bullet penetrating the composite target has been simulated using numerical method. The experiment provided the criteria for verifying the correctness of the numerical model. We have obtained tomographic data of bone by CT scans, and also defined the bone as different layers by the gray scale to simulate its heterogeneity. The computed results are in good agreement with the experimental data. Effects of the impact velocity and bone location on damage caused to the composite target have also been studied. The numerical results imply the follows: When the velocity of bullet increases, the stress on bone also increases with the earlier pressure peak; When the bone is located in a certain distance from the trajectory, it will not be fractured, although it is affected by the stress wave. PMID:26615390

  7. The experimental and numerical study of indirect effect of a rifle bullet on the bone.

    PubMed

    Zhang, Xiaoyun; Xu, Cheng; Wen, Yaoke; Luo, Shaomin

    2015-12-01

    We study the transient indirect effect of a rifle bullet on bone in the gelatin-bone composite target experimentally and computationally. The process of a 56 type 7.62-mm rifle bullet penetrating the composite target has been simulated using numerical method. The experiment provided the criteria for verifying the correctness of the numerical model. We have obtained tomographic data of bone by CT scans, and also defined the bone as different layers by the gray scale to simulate its heterogeneity. The computed results are in good agreement with the experimental data. Effects of the impact velocity and bone location on damage caused to the composite target have also been studied. The numerical results imply the follows: When the velocity of bullet increases, the stress on bone also increases with the earlier pressure peak; When the bone is located in a certain distance from the trajectory, it will not be fractured, although it is affected by the stress wave.

  8. Tantalum coating of porous carbon scaffold supplemented with autologous bone marrow stromal stem cells for bone regeneration in vitro and in vivo.

    PubMed

    Wei, Xiaowei; Zhao, Dewei; Wang, Benjie; Wang, Wei; Kang, Kai; Xie, Hui; Liu, Baoyi; Zhang, Xiuzhi; Zhang, Jinsong; Yang, Zhenming

    2016-03-01

    Porous tantalum metal with low elastic modulus is similar to cancellous bone. Reticulated vitreous carbon (RVC) can provide three-dimensional pore structure and serves as the ideal scaffold of tantalum coating. In this study, the biocompatibility of domestic porous tantalum was first successfully tested with bone marrow stromal stem cells (BMSCs) in vitro and for bone tissue repair in vivo. We evaluated cytotoxicity of RVC scaffold and tantalum coating using BMSCs. The morphology, adhesion, and proliferation of BMSCs were observed via laser scanning confocal microscope and scanning electron microscopy. In addition, porous tantalum rods with or without autologous BMSCs were implanted on hind legs in dogs, respectively. The osteogenic potential was observed by hard tissue slice examination. At three weeks and six weeks following implantation, new osteoblasts and new bone were observed at the tantalum-host bone interface and pores. At 12 weeks postporous tantalum with autologous BMSCs implantation, regenerated trabecular equivalent to mature bone was found in the pore of tantalum rods. Our results suggested that domestic porous tantalum had excellent biocompatibility and could promote new bone formation in vivo. Meanwhile, the osteogenesis of porous tantalum associated with autologous BMSCs was more excellent than only tantalum implantation. Future clinical studies are warranted to verify the clinical efficacy of combined implantation of this domestic porous tantalum associated with autologous BMSCs implantation and compare their efficacy with conventional autologous bone grafting carrying blood vessel in patients needing bone repairing.

  9. Tantalum coating of porous carbon scaffold supplemented with autologous bone marrow stromal stem cells for bone regeneration in vitro and in vivo

    PubMed Central

    Wei, Xiaowei; Wang, Benjie; Wang, Wei; Kang, Kai; Xie, Hui; Liu, Baoyi; Zhang, Xiuzhi; Zhang, Jinsong; Yang, Zhenming

    2016-01-01

    Porous tantalum metal with low elastic modulus is similar to cancellous bone. Reticulated vitreous carbon (RVC) can provide three-dimensional pore structure and serves as the ideal scaffold of tantalum coating. In this study, the biocompatibility of domestic porous tantalum was first successfully tested with bone marrow stromal stem cells (BMSCs) in vitro and for bone tissue repair in vivo. We evaluated cytotoxicity of RVC scaffold and tantalum coating using BMSCs. The morphology, adhesion, and proliferation of BMSCs were observed via laser scanning confocal microscope and scanning electron microscopy. In addition, porous tantalum rods with or without autologous BMSCs were implanted on hind legs in dogs, respectively. The osteogenic potential was observed by hard tissue slice examination. At three weeks and six weeks following implantation, new osteoblasts and new bone were observed at the tantalum–host bone interface and pores. At 12 weeks postporous tantalum with autologous BMSCs implantation, regenerated trabecular equivalent to mature bone was found in the pore of tantalum rods. Our results suggested that domestic porous tantalum had excellent biocompatibility and could promote new bone formation in vivo. Meanwhile, the osteogenesis of porous tantalum associated with autologous BMSCs was more excellent than only tantalum implantation. Future clinical studies are warranted to verify the clinical efficacy of combined implantation of this domestic porous tantalum associated with autologous BMSCs implantation and compare their efficacy with conventional autologous bone grafting carrying blood vessel in patients needing bone repairing. PMID:26843518

  10. Tantalum coating of porous carbon scaffold supplemented with autologous bone marrow stromal stem cells for bone regeneration in vitro and in vivo.

    PubMed

    Wei, Xiaowei; Zhao, Dewei; Wang, Benjie; Wang, Wei; Kang, Kai; Xie, Hui; Liu, Baoyi; Zhang, Xiuzhi; Zhang, Jinsong; Yang, Zhenming

    2016-03-01

    Porous tantalum metal with low elastic modulus is similar to cancellous bone. Reticulated vitreous carbon (RVC) can provide three-dimensional pore structure and serves as the ideal scaffold of tantalum coating. In this study, the biocompatibility of domestic porous tantalum was first successfully tested with bone marrow stromal stem cells (BMSCs) in vitro and for bone tissue repair in vivo. We evaluated cytotoxicity of RVC scaffold and tantalum coating using BMSCs. The morphology, adhesion, and proliferation of BMSCs were observed via laser scanning confocal microscope and scanning electron microscopy. In addition, porous tantalum rods with or without autologous BMSCs were implanted on hind legs in dogs, respectively. The osteogenic potential was observed by hard tissue slice examination. At three weeks and six weeks following implantation, new osteoblasts and new bone were observed at the tantalum-host bone interface and pores. At 12 weeks postporous tantalum with autologous BMSCs implantation, regenerated trabecular equivalent to mature bone was found in the pore of tantalum rods. Our results suggested that domestic porous tantalum had excellent biocompatibility and could promote new bone formation in vivo. Meanwhile, the osteogenesis of porous tantalum associated with autologous BMSCs was more excellent than only tantalum implantation. Future clinical studies are warranted to verify the clinical efficacy of combined implantation of this domestic porous tantalum associated with autologous BMSCs implantation and compare their efficacy with conventional autologous bone grafting carrying blood vessel in patients needing bone repairing. PMID:26843518

  11. Bone stress lesions in ballet dancers: scintigraphic assessment.

    PubMed

    Nussbaum, A R; Treves, S T; Micheli, L

    1988-04-01

    Ballet dancers are athletes susceptible to ligamentous and bony injury. We reviewed retrospectively the bone scans (technetium-99m methylene diphosphonate) of 23 ballet dancers with pain in the back and/or lower extremities to determine the usefulness of scintigraphy in the detection of stress lesions of bone. The scintigraphic studies in 19 dancers identified multiple areas of stress injury in both symptomatic and asymptomatic locations. Thirteen dancers had 22 stress fractures (microfractures of trabeculae with associated bone repair) manifested by an intense focus of increased uptake of radiopharmaceutical, and 19 dancers had stress reactions (areas of accelerated remodeling and resorption of bone) demonstrated by diffusely increased uptake of radiotracer. Ten of the 13 dancers with stress fractures were symptomatic and six of the 19 dancers with stress reactions were symptomatic. The radiographs of 10 dancers with positive bone scans were normal or showed no distinction between acute and chronic injuries. Stress fractures were most prevalent in the feet, and stress reactions were most prevalent in the tibiae. The study confirmed that ballet dancers sustain significant bone stress in their legs and feet. Our results show that scintigraphy can be used to detect stress fractures and stress reactions at both symptomatic and asymptomatic sites in this population.

  12. Bone and Celiac Disease.

    PubMed

    Zanchetta, María Belén; Longobardi, Vanesa; Bai, Julio César

    2016-04-01

    More than 50% of untreated patients with celiac disease (CD) have bone loss detected by bone densitometry (dual-energy X-ray absorptiometry:DXA). Moreover, patients with CD are more likely to have osteoporosis and fragility fractures, especially of the distal radius. Although still controversial, we recommend DXA screening in all celiac disease patients, particularly in those with symptomatic CD at diagnosis and in those who present risk factors for fracture such as older age, menopausal status, previous fracture history, and familial hip fracture history. Bone microarchitecture, especially the trabecular network, may be deteriorated, explaining the higher fracture risk in these patients. Adequate calcium and vitamin D supplementation are also recommended to optimize bone recovery, especially during the first years of gluten free diet (GFD). If higher fracture risk persists after 1 or 2 years of GFD, specific osteoactive treatment may be necessary to improve bone health.

  13. Ultrasonic bone densitometer

    NASA Technical Reports Server (NTRS)

    Hoop, J. M. (Inventor)

    1974-01-01

    A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

  14. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    SciTech Connect

    Sty, J.; Simons, G.

    1982-05-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success.

  15. Bone-seeking radiopharmaceuticals as targeted agents of osteosarcoma: samarium-153-EDTMP and radium-223.

    PubMed

    Anderson, Peter M; Subbiah, Vivek; Rohren, Eric

    2014-01-01

    Osteosarcoma is a cancer characterized by formation of bone by malignant cells. Routine bone scan imaging with Tc-99m-MDP is done at diagnosis to evaluate primary tumor uptake and check for bone metastases. At time of relapse the Tc-99m-MDP bone scan also provides a specific means to assess formation of bone by malignant osteosarcoma cells and the potential for bone-seeking radiopharmaceuticals to deliver radioactivity directly into osteoblastic osteosarcoma lesions. This chapter will review and compare a bone-seeking radiopharmaceutical that emits beta-particles, samarium-153-EDTMP, with an alpha-particle emitter, radium-223. The charged alpha particles from radium-223 have far more mass and energy than beta particles (electrons) from Sm-153-EDTMP. Because radium-223 has less marrow toxicity and more radiobiological effectiveness, especially if inside the bone forming cancer cell than samarium-153-EDTMP, radium-223 may have greater potential to become widely used against osteosarcoma as a targeted therapy. Radium-223 also has more potential to be used with chemotherapy against osteosarcoma and bone metastases. Because osteosarcoma makes bone and radium-223 acts like calcium, this radiopharmaceutical could possibly become a new targeted means to achieve safe and effective reduction of tumor burden as well as facilitate better surgery and/or radiotherapy for difficult to resect large, or metastatic tumors.

  16. Trabecular Bone Mechanical Properties and Fractal Dimension

    NASA Technical Reports Server (NTRS)

    Hogan, Harry A.

    1996-01-01

    Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again

  17. Finite element analysis of a femur to deconstruct the paradox of bone curvature.

    PubMed

    Jade, Sameer; Tamvada, Kelli H; Strait, David S; Grosse, Ian R

    2014-01-21

    Most long limb bones in terrestrial mammals exhibit a longitudinal curvature and have been found to be loaded in bending. Bone curvature poses a paradox in terms of the mechanical function of limb bones, for many believe the curvature in these bones increases bending stress, potentially reducing the bone's load carrying capacity (i.e., its mechanical strength). The aim of this study is to investigate the role of longitudinal bone curvature in the design of limb bones. In particular, it has been hypothesized that bone curvature results in a trade-off between the bone's mechanical strength and its bending predictability. We employed finite element analysis (FEA) of abstract and realistic human femora to address this issue. Geometrically simplified human femur models with different curvatures were developed and analyzed with a commercial FEA tool to examine how curvature affects the bone's bending predictability and load carrying capacity. Results were post-processed to yield probability density functions (PDFs) describing the circumferential location of maximum equivalent stress for various curvatures in order to assess bending predictability. To validate our findings, a finite element model was built from a CT scan of a real human femur and compared to the simplified femur model. We found general agreement in trends but some quantitative differences most likely due to the geometric differences between the digitally reconstructed and the simplified finite element models. As hypothesized by others, our results support the hypothesis that bone curvature can increase bending predictability, but at the expense of bone strength.

  18. Effect of in vivo loading on bone composition varies with animal age

    PubMed Central

    Aido, Marta; Kerschnitzki, Michael; Hoerth, Rebecca; Checa, Sara; Spevak, Lyudmila; Boskey, Adele; Fratzl, Peter; Duda, Georg N.; Wagermaier, Wolfgang; Willie, Bettina M.

    2015-01-01

    Loading can increase bone mass and size and this response is reduced with aging. It is unclear, however how loading affects bone mineral and matrix properties. Fourier Transform Infrared Imaging and high resolution synchrotron scanning small angle X-ray scattering were used to study how bone’s microscale and nanoscale compositional properties were altered in the tibial midshaft of young, adult, and elderly female C57Bl/6J mice after two weeks of controlled in vivo compressive loading in comparison to physiological loading. The effect of controlled loading on bone composition varied with animal age, since it predominantly influenced the bone composition of elderly mice. Interestingly, controlled loading led to enhanced collagen maturity in elderly mice. In addition, although the rate of bone formation was increased by controlled loading based on histomorphometry, the newly formed tissue had similar material quality to new bone tissue formed during physiological loading. Similar to previous studies, our data showed that bone composition was animal and tissue age dependent during physiological loading. The findings that the new tissue formed in response to controlled loading and physiological loading had similar bone composition and that controlled loading enhanced bone composition in elderly mice further supports the use of physical activity as a noninvasive treatment to enhance bone quality as well as maintain bone mass in individuals suffering from age-related bone loss. PMID:25639943

  19. Osteoporotic bone microstructure by collagenase etching.

    PubMed Central

    Mackie, I G; Green, M; Clarke, H; Isaac, D H

    1989-01-01

    Collagenase etching has been used to show the microstructure of bone from patients suffering from primary osteoporosis. Both polished and unpolished surfaces of trabecular bone from femoral heads were treated with collagenase solution before study in the scanning electron microscope. The polished surfaces show the mineral component of this bone as small rounded units approximately 10-20 nm across, which aggregate to form a continuous phase of contiguous spheroidal particles approximately 100 nm across. Lamellations are clearly seen to be due to the removal of collagen fibres up to approximately 200 nm across, fibres in adjacent lamellae being arranged approximately perpendicular to each other. The unpolished surfaces also show small rounded units, which aggregate into rods of mineral approximately 100 nm across. Although these rods form a connected system, they are loosely packed, compatible with their being interspersed with the collagen fibres in vivo. This model for the detailed microstructure of bone is consistent with specimens from a number of other sources and shows no features unique to osteoporosis. Images PMID:2545170

  20. Pullulan microcarriers for bone tissue regeneration.

    PubMed

    Aydogdu, Hazal; Keskin, Dilek; Baran, Erkan Turker; Tezcaner, Aysen

    2016-06-01

    Microcarrier systems offer a convenient way to repair bone defects as injectable cell carriers that can be applied with small incisions owing to their small size and spherical shape. In this study, pullulan (PULL) microspheres were fabricated and characterized as cell carriers for bone tissue engineering applications. PULL was cross-linked by trisodium trimetaphosphate (STMP) to enhance the stability of the microspheres. Improved cytocompatibility was achieved by silk fibroin (SF) coating and biomimetic mineralization on the surface by incubating in simulated body fluid (SBF). X-ray diffraction (XRD), scanning electron microscopy (SEM) and fluorescent microscopy analysis confirmed biomimetic mineralization and SF coating on microspheres. The degradation analysis revealed that PULL microspheres had a slow degradation rate with 8% degradation in two weeks period indicating that the microspheres would support the formation of new bone tissue. Furthermore, the mechanical tests showed that the microspheres had a high mechanical stability that was significantly enhanced with the biomimetic mineralization. In vitro cell culture studies with SaOs-2 cells showed that cell viability was higher on SF and SBF coated microspheres on 7th day compared to PULL ones under dynamic conditions. Alkaline phosphatase activity was higher for SF coated microspheres in comparison to uncoated microspheres when dynamic culture condition was applied. The results suggest that both organic and inorganic surface modifications can be applied on PULL microspheres to prepare a biocompatible microcarrier system with suitable properties for bone tissue engineering. PMID:27040238

  1. Re-scan confocal microscopy: scanning twice for better resolution.

    PubMed

    De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.

  2. Lidar arc scan uncertainty reduction through scanning geometry optimization

    NASA Astrophysics Data System (ADS)

    Wang, H.; Barthelmie, R. J.; Pryor, S. C.; Brown, G.

    2015-10-01

    Doppler lidars are frequently operated in a mode referred to as arc scans, wherein the lidar beam scans across a sector with a fixed elevation angle and the resulting measurements are used to derive an estimate of the n minute horizontal mean wind velocity (speed and direction). Previous studies have shown that the uncertainty in the measured wind speed originates from turbulent wind fluctuations and depends on the scan geometry (the arc span and the arc orientation). This paper is designed to provide guidance on optimal scan geometries for two key applications in the wind energy industry: wind turbine power performance analysis and annual energy production. We present a quantitative analysis of the retrieved wind speed uncertainty derived using a theoretical model with the assumption of isotropic and frozen turbulence, and observations from three sites that are onshore with flat terrain, onshore with complex terrain and offshore, respectively. The results from both the theoretical model and observations show that the uncertainty is scaled with the turbulence intensity such that the relative standard error on the 10 min mean wind speed is about 30 % of the turbulence intensity. The uncertainty in both retrieved wind speeds and derived wind energy production estimates can be reduced by aligning lidar beams with the dominant wind direction, increasing the arc span and lowering the number of beams per arc scan. Large arc spans should be used at sites with high turbulence intensity and/or large wind direction variation when arc scans are used for wind resource assessment.

  3. SILICON AND BONE HEALTH

    PubMed Central

    JUGDAOHSINGH, R.

    2009-01-01

    Low bone mass (osteoporosis) is a silent epidemic of the 21st century, which presently in the UK results in over 200,000 fractures annually at a cost of over one billion pounds. Figures are set to increase worldwide. Understanding the factors which affect bone metabolism is thus of primary importance in order to establish preventative measures or treatments for this condition. Nutrition is an important determinant of bone health, but the effects of the individual nutrients and minerals, other than calcium, is little understood. Accumulating evidence over the last 30 years strongly suggest that dietary silicon is beneficial to bone and connective tissue health and we recently reported strong positive associations between dietary Si intake and bone mineral density in US and UK cohorts. The exact biological role(s) of silicon in bone health is still not clear, although a number of possible mechanisms have been suggested, including the synthesis of collagen and/or its stabilization, and matrix mineralization. This review gives an overview of this naturally occurring dietary element, its metabolism and the evidence of its potential role in bone health. PMID:17435952

  4. Temporal bone chondroblastoma totally invisible on MRI.

    PubMed

    Hiraumi, Harukazu; Arakawa, Yoshiki; Yamamoto, Norio; Sakamoto, Tatsunori; Ito, Juichi

    2016-08-01

    We report a case of temporal bone chondroblastoma that was totally invisible on MRI. The patient was a 64-year-old man who presented with several months history of vertigo. The CT scan with bone window setting showed destruction of the temporomandibular joint, the floor of the middle cranial fossa, and the superior semicircular canal. Calcific foci were seen within the tumor. On MR imaging, the tumor, situating mainly medial to the temporomandibular joint, showed no signal on both T1- and T2-weighted images. The tumor was not enhanced with gadolinium. In summary, the tumor was totally signal negative or "invisible" on pre- and postcontrast T1- and T2-weighted images. The tumor was resected through transpetrosal - transzygomatic approach.

  5. Temporal bone chondroblastoma totally invisible on MRI.

    PubMed

    Hiraumi, Harukazu; Arakawa, Yoshiki; Yamamoto, Norio; Sakamoto, Tatsunori; Ito, Juichi

    2016-08-01

    We report a case of temporal bone chondroblastoma that was totally invisible on MRI. The patient was a 64-year-old man who presented with several months history of vertigo. The CT scan with bone window setting showed destruction of the temporomandibular joint, the floor of the middle cranial fossa, and the superior semicircular canal. Calcific foci were seen within the tumor. On MR imaging, the tumor, situating mainly medial to the temporomandibular joint, showed no signal on both T1- and T2-weighted images. The tumor was not enhanced with gadolinium. In summary, the tumor was totally signal negative or "invisible" on pre- and postcontrast T1- and T2-weighted images. The tumor was resected through transpetrosal - transzygomatic approach. PMID:26743837

  6. Distribution of radiological density in bone regenerate in relation to cyclic displacements of bone fragments.

    PubMed

    Filipiak, Jaroslaw; Krawczyk, Artur; Morasiewicz, Leszek

    2009-01-01

    We asked how bone fragment displacement could influence the distribution of radiological density in bone regenerate formed during the process of bone lengthening. The metatarsi of 21 sheep were lengthened by 20 mm by the Ilizarov method. The bone fragments were externally fixed with a specially designed ring external fixator equipped with linear actuator driver system. The test sheep were divided into three experimental groups: the G1 and G2 groups (N = 8) and the GR group (N = 5)--the reference group. In the case of sheep from the G1 and G2 groups, the lengthening was supplemented with mechanical stimulation of the regenerate in the form of cyclic bone fragment displacements (CBFDs) with the amplitudes of 1 mm (G1) and 2 mm (G1). Mechanical stimulation was applied over 30 days for 1 h per day with a frequency of 1 Hz. Eight weeks after the procedure the sheep were sacrificed in accordance with the required procedures. The analysis of the degree of bone regenerate mineralization involved the studies based on the CT scanning. The analysis of the results obtained is based on the paramenter called the degree of regenerate mineralization (RMD). The analysis of radiological density was carried out in the selected measurement areas. Such an area was located in three horizontal zones, taking into account the regenerate height, i.e. in its middle part (half regenerate length); the top part, 2 mm from the edge of the proximal fragment; and the bottom part, 2 mm from the edge of the distal fragment. The value of the RMD parameter varies significantly, depending on the bone regenerate area. The results obtained show that the CBFD = 2 mm accelerates the rate of mineralization of an eight-week-old regenerate. In the case of CBFD = 1 mm, the mineralization rate is lower by more than a dozen per cent.

  7. [Determinants of bone quality and strength independent of bone remodeling].

    PubMed

    Saito, Mitsuru; Marumo, Keishi

    2016-01-01

    Bone mineral density(BMD)and bone microstructure are regulated mainly by bone remodeling. In contrast, bone collagen enzymatic immature and mature cross-links and advanced glycation end products such as pentosidine and carboxyl methyl lysine are affected by various factors. Aging bone tissue is repaired in the process of bone remodeling. However, deterioration of bone material properties markedly advances due to increases in oxidative stress, glycation stress, reactive oxygen species, carbonyl stress associated with aging and reduced sex hormone levels, and glucocorticoid use. To improve bone material properties in osteoporosis, we should use different drug (Saito M, Calcif Tissue Int, REVIEW, 97;242-261, 2015). In this review, we summarized determinants of bone quality and strength independent of bone remodeling. PMID:26728528

  8. Three-Dimensional Porous Gelapin-Simvastatin Scaffolds Promoted Bone Defect Healing in Rabbits.

    PubMed

    Moshiri, Ali; Shahrezaee, Mostafa; Shekarchi, Babak; Oryan, Ahmad; Azma, Kamran

    2015-06-01

    Treatment of large bone defects (LBDs) is technically demanding. Tissue engineering is an option. A bioactive graft may be produced by combining tissue scaffolds and healing promotive factors in order to accelerate bone repair. We investigated the role of Simvastatin (Sim)-embedded porous Gelapin (Gel) scaffold on experimental bone healing. At first, the effectiveness of different concentrations of Gel and Sim powders was investigated in an experimentally induced femoral hole model in rabbits (n = 6) for 30 days. Then bone bioactive grafts were produced by combination of the effective concentrations of Gel, Sim, and Genipin. The bioimplants were subcutaneously tested in a rabbit model (n = 9) to determine their biocompatibility and biodegradability for 10-30 days. Finally, a large radial bone defect model was produced in rabbits (n = 20), and the bioimplants were inserted in the defects. The untreated and autograft-treated bone defects were served as controls. The animals were euthanized after 30 and 60 days of bone injury. The bone samples were evaluated by radiography, three-dimensional CT scan, bone densitometry, histopathology, and nano-indentation. At a concentration of 5 mg/hole, Sim closed the femoral bone holes after 30 days, while in the defect, autograft, and Gel groups, the holes were open. Both the Gel and Gel-Sim scaffolds were biocompatible and biodegradable. Subcutaneously, the Gel-Sim scaffold was replaced with the newly regenerated ectopic bone after 30 days. After implantation of the Gel-Sim scaffold in the radial bone defects, the scaffold was completely replaced with new woven bone after 30 days which was then matured and remodeled into a cortical bone after 60 days. Sixty days after bone injury, the Gel-Sim-treated defects had significantly higher bone volume, matrix mineralization, elastic modulus, and contact hardness when compared to the controls. The Gel-Sim scaffold may be a suitable option in managing LBDs. PMID:25804980

  9. Experimental tomographic scanning (TOSCA) imagers

    NASA Astrophysics Data System (ADS)

    Hovland, H.

    2014-06-01

    The tomographic scanner (TOSCA) detects signals using line detectors scanning a scene at regularly distributed angles. These line scan signals are then processed to reconstruct 2-dimensional images. In the simplest form, a 1-axis rotating conical scan optics scans across a simple patterned reticle, the signal collection being done with a single pixel detector. Experimental mono- and multispectral cameras using this approach are demonstrated under varying illumination conditions. Of particular interest is the TOSCA system's ability to handle and compensate for light sources modulated with a frequency higher than that of the frame rate. We also demonstrate for the first time a TOSCA imager operating in the infrared region. The device is put together using 3D-printed key parts and low cost optical components, leading to a very economical infrared camera.

  10. Transverse section radionuclide scanning system

    DOEpatents

    Kuhl, David E.; Edwards, Roy Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three-dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program.

  11. Scans as primitive parallel operations

    SciTech Connect

    Blelloch, G.E. . Dept. of Computer Science)

    1989-11-01

    In most parallel random access machine (PRAM) models, memory references are assumed to take unit time. In practice, and in theory, certain scan operations, also known as prefix computations, can execute in no more time than these parallel memory references. This paper outlines an extensive study of the effect of including, in the PRAM models, such scan operations as unit-time primitives. The study concludes that the primitives improve the asymptotic running time of many algorithms by an O(log n) factor greatly simplify the description of many algorithms, and are significantly easier to implement than memory references. The authors argue that the algorithm designer should feel free to use these operations as if they were as cheap as a memory reference. This paper describes five algorithms that clearly illustrate how the scan primitives can be used in algorithm design. These all run on an EREW PRAM with the addition of two scan primitives.

  12. Eddy current scanning at Fermilab

    SciTech Connect

    Boffo, C.; Bauer, P.; Foley, M.; Brinkmann, A.; Ozelis, J.; /Jefferson Lab

    2005-07-01

    In the framework of SRF cavity development, Fermilab is creating the infrastructure needed for the characterization of the material used in the cavity fabrication. An important step in the characterization of ''as received'' niobium sheets is the eddy current scanning. Eddy current scanning is a non-destructive technique first adopted and further developed by DESY with the purpose of checking the cavity material for sub-surface defects and inclusions. Fermilab has received and further upgraded a commercial eddy current scanner previously used for the SNS project. The upgrading process included developing new filtering software. This scanner is now used daily to scan the niobium sheets for the Fermilab third harmonic and transverse deflecting cavities. This paper gives a status report on the scanning results obtained so far, including a discussion of the typology of signals being detected. We also report on the efforts to calibrate this scanner, a work conducted in collaboration with DESY.

  13. 3D light scanning macrography.

    PubMed

    Huber, D; Keller, M; Robert, D

    2001-08-01

    The technique of 3D light scanning macrography permits the non-invasive surface scanning of small specimens at magnifications up to 200x. Obviating both the problem of limited depth of field inherent to conventional close-up macrophotography and the metallic coating required by scanning electron microscopy, 3D light scanning macrography provides three-dimensional digital images of intact specimens without the loss of colour, texture and transparency information. This newly developed technique offers a versatile, portable and cost-efficient method for the non-invasive digital and photographic documentation of small objects. Computer controlled device operation and digital image acquisition facilitate fast and accurate quantitative morphometric investigations, and the technique offers a broad field of research and educational applications in biological, medical and materials sciences. PMID:11489078

  14. Insufficiency of Bone Scintigraphy in Vertebral Lesions of Langerhans Cell Histiocytosis Compared to F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and Diagnostic Computed Tomography

    PubMed Central

    Koç, Zehra Pınar; Şimşek, Selçuk; Akarsu, Saadet; Balcı, Tansel Ansal; Onur, Mehmet Ruhi; Kepenek, Ferat

    2015-01-01

    Langerhans cell histiocytosis (LCH) is a benign disorder related to the histiocytes which can infiltrate bone tissue. The most effective method for demonstrating severity of this disease is PET/CT and bone scintigraphy might show bone lesions. We present a seventeen year old male patient with disseminated LCH presented with exophtalmos and having multiple vertebral lesions which were identified by F-18 FDG PET/CT scan and diagnostic CT but not in the bone scintigraphy. PMID:25800594

  15. Insufficiency of bone scintigraphy in vertebral lesions of langerhans cell histiocytosis compared to f-18 fluorodeoxyglucose positron emission tomography/computed tomography and diagnostic computed tomography.

    PubMed

    Koç, Zehra Pınar; Şimşek, Selçuk; Akarsu, Saadet; Balcı, Tansel Ansal; Onur, Mehmet Ruhi; Kepenek, Ferat

    2015-02-01

    Langerhans cell histiocytosis (LCH) is a benign disorder related to the histiocytes which can infiltrate bone tissue. The most effective method for demonstrating severity of this disease is PET/CT and bone scintigraphy might show bone lesions. We present a seventeen year old male patient with disseminated LCH presented with exophtalmos and having multiple vertebral lesions which were identified by F-18 FDG PET/CT scan and diagnostic CT but not in the bone scintigraphy.

  16. Aspiration and Biopsy: Bone Marrow

    MedlinePlus

    ... Help a Friend Who Cuts? Aspiration and Biopsy: Bone Marrow KidsHealth > For Teens > Aspiration and Biopsy: Bone Marrow Print A A A Text Size What's in ... Risks If You Have Questions What It Is Bone marrow aspirations and biopsies are performed to examine bone ...

  17. Bone Remodeling Under Pathological Conditions.

    PubMed

    Xiao, Wenmei; Li, Shuai; Pacios, Sandra; Wang, Yu; Graves, Dana T

    2016-01-01

    Bone is masterfully programmed to repair itself through the coupling of bone formation following bone resorption, a process referred to as coupling. In inflammatory or other conditions, the balance between bone resorption and bone formation shifts so that a net bone loss results. This review focuses on four pathologic conditions in which remodeling leads to net loss of bone, postmenopausal osteoporosis, arthritis, periodontal disease, and disuse bone loss, which is similar to bone loss associated with microgravity. In most of these there is an acceleration of the resorptive process due to increased formation of bone metabolic units. This initially leads to a net bone loss since the time period of resorption is much faster than the time needed for bone formation that follows. In addition, each of these processes is characterized by an uncoupling that leads to net bone loss. Mechanisms responsible for increased rates of bone resorption, i.e. the formation of more bone metabolic units, involve enhanced expression of inflammatory cytokines and increased expression of RANKL. Moreover, the reasons for uncoupling are discussed which range from a decrease in expression of growth factors and bone morphogenetic proteins to increased expression of factors that inhibit Wnt signaling. PMID:26599114

  18. A Biphasic Calcium Sulphate/Hydroxyapatite Carrier Containing Bone Morphogenic Protein-2 and Zoledronic Acid Generates Bone

    PubMed Central

    Raina, Deepak Bushan; Isaksson, Hanna; Hettwer, Werner; Kumar, Ashok; Lidgren, Lars; Tägil, Magnus

    2016-01-01

    In orthopedic surgery, large amount of diseased or injured bone routinely needs to be replaced. Autografts are mainly used but their availability is limited. Commercially available bone substitutes allow bone ingrowth but lack the capacity to induce bone formation. Thus, off-the-shelf osteoinductive bone substitutes that can replace bone grafts are required. We tested the carrier properties of a biphasic, calcium sulphate and hydroxyapatite ceramic material, containing a combination of recombinant human bone morphogenic protein-2 (rhBMP-2) to induce bone, and zoledronic acid (ZA) to delay early resorption. In-vitro, the biphasic material released 90% of rhBMP-2 and 10% of ZA in the first week. No major changes were found in the surface structure using scanning electron microscopy (SEM) or in the mechanical properties after adding rhBMP-2 or ZA. In-vivo bone formation was studied in an abdominal muscle pouch model in rats (n = 6/group). The mineralized volume was significantly higher when the biphasic material was combined with both rhBMP-2 and ZA (21.4 ± 5.5 mm3) as compared to rhBMP-2 alone (10.9 ± 2.1 mm3) when analyzed using micro computed tomography (μ-CT) (p < 0.01). In the clinical setting, the biphasic material combined with both rhBMP-2 and ZA can potentially regenerate large volumes of bone. PMID:27189411

  19. Delayed bone cement displacement following balloon kyphoplasty.

    PubMed

    Wang, Hee Sun; Kim, Hyeun Sung; Ju, Chang Il; Kim, Seok Won

    2008-04-01

    We report a rare case of delayed cement displacement after balloon kyphoplasty in patient with Kümmell's desease. A 78-year-old woman with Kümmell's desease at T12 level received percutaneous balloon kyphoplasty. Two months after surgery, the patient complained of progressive severe back pain. Computed tomographic scans revealed a breakdown of the anterior cortex and anterior displacement of bone cement. Although this complication is very rare, it is likely to occur in treatment of Kümmell's desease accompanying anterior cortical defect. PMID:19096648

  20. Bone SPECT/CT in skeletal trauma.

    PubMed

    Scharf, Stephen C

    2015-01-01

    The utility of radionuclide bone scanning in skeletal trauma has been greatly enhanced over the last decade by hybrid technology merging multislice CT with SPECT that can take advantage of CT-based correction of attenuation and scatter. The resulting images have been particularly helpful in giving us new insights into the evaluation of foot and ankle injuries and vertebral pathology both before and after surgery. The physiological information and anatomical detail allow a better understanding of the causes of patients' pain and have proven to be particularly useful in planning surgical intervention.