Science.gov

Sample records for 3-phase bone scan

  1. Bone Scan

    MedlinePlus

    ... Mayo Clinic Staff A bone scan is a nuclear imaging test that helps diagnose and track several ... you're nursing. A bone scan is a nuclear imaging procedure. In nuclear imaging, tiny amounts of ...

  2. Bone density scan (image)

    MedlinePlus

    ... bone the higher the risk of fractures. A bone scan, along with a patient's medical history, is a ... and whether any preventative treatment is needed. A bone density scan has the advantage of being painless and exposing ...

  3. Bone scanning in otolaryngology.

    PubMed

    Noyek, A M

    1979-09-01

    Modern radionuclide bone scanning has introduced a new concept in physiologic and anatomic diagnostic imaging to general medicine. As otolaryngologists must diagnose and treat disease in relation to the bony and/or cartilaginous supporting structures of the neurocranium and upper airway, this modality should be included in the otolaryngologist's diagnostic armamentarium. It is the purpose of this manuscript to study the specific applications of bone scanning to our specialty at this time, based on clinical experience over the past three years. This thesis describes the development of bone scanning in general (history of nuclear medicine and nuclear physics; history of bone scanning in particular). General concepts in nuclear medicine are then presented; these include a discussion of nuclear semantics, principles of radioactive emmissions, the properties 99mTc as a radionuclide, and the tracer principle. On the basis of these general concepts, specific concepts in bone scanning are then brought forth. The physiology of bone and the action of the bone scan agents is presented. Further discussion considers the availability and production of the bone scan agent, patient factors, the gamma camera, the triphasic bone scan and the ultimate diagnostic principle of the bone scan. Clinical applications of bone scanning in otolaryngology are then presented in three sections. Proven areas of application include the evaluation of malignant tumors of the head and neck, the diagnosis of temporomandibular joint disorders, the diagnosis of facial fractures, the evaluation of osteomyelitis, nuclear medicine imaging of the larynx, and the assessment of systemic disease. Areas of adjunctive or supplementary value are also noted, such as diagnostic imaging of meningioma. Finally, areas of marginal value in the application of bone scanning are described.

  4. Bone scanning in clinical practice

    SciTech Connect

    Fogelman, I. )

    1987-01-01

    The topics covered in this book include the history of bone scanning, mechanisms of uptake of diphosphonate in bone, the normal bone scan, and the role of bone scanning in clinical practice. The aim of this book is to provide a source of reference relating to bone scan imaging for all those who are interested in the skeleton.

  5. Bone scan in metabolic bone diseases. Review.

    PubMed

    Abdelrazek, Saeid; Szumowski, Piotr; Rogowski, Franciszek; Kociura-Sawicka, Agnieszka; Mojsak, Małgorzata; Szorc, Małgorzata

    2012-08-25

    Metabolic bone disease encompasses a number of disorders that tend to present a generalized involvement of the whole skeleton. The disorders are mostly related to increased bone turnover and increased uptake of radiolabelled diphosphonate. Skeletal uptake of 99mTc-labelled diphosphonate depends primarily upon osteoblastic activity, and to a lesser extent, skeletal vascularity. A bone scan image therefore presents a functional display of total skeletal metabolism and has valuable role to play in the assessment of patients with metabolic bone disorders. However, the bone scan appearances in metabolic bone disease are often non-specific, and their recognition depends on increased tracer uptake throughout the whole skeleton. It is the presence of local lesions, as in metastatic disease, that makes a bone scan appearance obviously abnormal. In the early stages, there will be difficulty in evaluating the bone scans from many patients with metabolic bone disease. However, in the more severe cases scan appearances can be quite striking and virtually diagnostic.

  6. Bone Densitometry (Bone Density Scan)

    MedlinePlus

    ... and display the bone density measurements on a computer monitor. top of page How is the procedure performed? ... passed over the area, generating images on a computer monitor. You must hold very still and may be ...

  7. Bone scan appearances following bone and bone marrow biopsy

    SciTech Connect

    McKillop, J.H.; Maharaj, D.; Boyce, B.F.; Fogelman, I.

    1984-01-01

    Bone marrow and bone biopsies are performed not infrequently in patients referred for bone scans and represent a potential cause of a ''false positive'' focal abnormality on the bone scan. The authors have therefore examined the scan appearances in a series of patients who had undergone either sternal marrow biopsy, (Salah needle, diameter 1.2 mm) trephine iliac crest marrow biopsy (Jamshidi 11 gauge needle, diameter 3.5 mm) or a transiliac bone biopsy (needle diameter 8 mm). Of 18 patients studied 1 to 45 days after sternal marrow 17 had normal scan appearances at the biopsy site and 1 had a possible abnormality. None of 9 patients studied 4 to 19 days after trephine iliac crest marrow biopsy had a hot spot at the biopsy site. A focal scan abnormality was present at the biopsy site in 9/11 patients studied 5 to 59 days after a trans iliac bone biopsy. No resultant scan abnormality was seen in 4 patients imaged within 3 days of the bone biopsy or in 3 patients imaged 79 to 138 days after the procedure. Bone marrow biopsy of the sternum or iliac crest does not usually cause bone scan abnormalities. A focal abnormality at the biopsy site is common in patients imaged 5 days to 2 months after bone biopsy. The gauge of the needle employed in the biopsy and thus the degree of bone trauma inflicted, is likely to be main factor determining the appearance of bone scan abnormalities at the biopsy site.

  8. Bone scan appearances following biopsy of bone and bone marrow

    SciTech Connect

    McKillop, J.H.; Maharaj, D.; Boyce, B.F.; Fogelman, I.

    1984-10-01

    The influence of sternal marrow aspiration, iliac crest marrow aspiration, and iliac crest bone biopsy on bone scan appearances was examined. Eighteen patients were scanned a mean of 9.9 days after sternal marrow aspiration with a Salah needle. Bone scans obtained in 9 patients a mean of 10 days aftr iliac crest trephine marrow biopsy with a Jamshidi needle showed no abnormality at the biopsy site. In 18 patients with metabolic bone disease who had undergone iliac crest bone biopsy with an 8 mm needle, a scan abnormality due to the biopsy was usually present when the interval between the biopsy and the scan was 5 days to 2 months. Patients who were scanned within 3 days of iliac crest bone biopsy or more than 2 months after biopsy had normal scan appearance at the biopsy site.

  9. Appearance of extraosseous pelvic Ewing sarcoma on triphasic bone scan.

    PubMed

    Muckle, Marianne; Habibi, Elham; Simon, Birgit; Zipfel, Matthias; Biersack, Hans Jürgen; Ahmadzadehfar, Hojjat

    2014-04-01

    A 24-year-old man with extraosseous Ewing sarcoma in the pelvis underwent a triphasic bone scintigraphy to rule out bone metastases and local bone infiltration before chemotherapy. The bone scintigraphy showed tracer uptake in the tumor in all 3 phases.

  10. Bone scan alterations in aromatase inhibitor-treated patients.

    PubMed

    De Geeter, Frank; Van den Bruel, Annick; De Cuypere, Eveline; Langlois, Michel

    2015-01-01

    We report bone scan changes in 3 patients receiving aromatase inhibitors as adjuvant treatment for postmenopausal hormone receptor-positive breast cancer. Compared with bone scans before treatment, repeated scans after at least 10 months of aromatase inhibitor treatment showed increased activity in the peripheral skeleton and the skull. In 2 patients, these alterations could be correlated with increased markers of bone turnover. They probably result from high bone turnover induced by estrogen depletion caused by aromatase inhibitors. This effect should be taken into account in the differential diagnosis of a bone scan pattern suggestive of hyperparathyroidism, which was ruled out.

  11. Use of serial bone scans in assessing response of bone metastases to systemic treatment

    SciTech Connect

    Citrin, D.L.; Hougen, C.; Zweibel, W.; Schlise, S.; Pruitt, B.; Ershler, W.; Davis, T.E.; Harberg, J.; Cohen, A.I.

    1981-02-15

    The accuracy levels of serial radioisotope bone scans and conventional bone radiographs in assessing the response of bone metastases to systemic therapy were compared in 34 women with metastatic breast cancer. Each patient had measurable or evaluable nonosseous metastases, which were assessed independently of skeletal disease. The bone scan was found to be more accurate and sensitive indicator of the status of bone metastases than the radiograph. The bone scan correlated well with response of soft tissue or visceral disease, while the results of repeated bone radiographs were frequently misleading. With use of a digital model, it was possible to accurately measure the area of skeletal involvement of the bone scan, and from this derive quantitative criteria for response in bone metastases analogous to response criteria currently in use for soft tissue and visceral disease. It is suggested that serial quantitative bone scans be done, in preference to radiographs, to assess the response of bone metastases to systemic therapy.

  12. Detection of ureteral obstruction on radionuclide bone scans

    SciTech Connect

    Pollen, J.J.; Gerber, K.; Heil, B.J.; Talner, L.B.

    1983-09-01

    The kidneys are nearly always visible on a routine radionuclide bone scan. To assess the reliability of the bone scan in detecting ureteral obstruction, 220 bone scans and excretory urograms were compared in 53 patients followed serially for prostatic cancer. There were 15 kidneys obstructed on excretory urograms. Only nine were diagnosed as obstructed on the bone scans. Seven of the nine cases of unilaterally obstructed kidneys were detected, whereas only two of the six kidneys in three patients with bilateral obstruction were correctly diagnosed. The results indicate that unilateral obstruction is more likely to be detected, whereas bilateral obstruction is more likely to be missed, on bone scans. Therefore, the routine radionuclide bone scan is an unreliable test for ureteral obstruction.

  13. Bone scanning in the detection of occult fractures

    SciTech Connect

    Batillas, J.; Vasilas, A.; Pizzi, W.F.; Gokcebay, T.

    1981-07-01

    The potential role of bone scanning in the early detection of occult fractures following acute trauma was investigated. Technetium 99m pyrophosphate bone scans were obtained in patients with major clinical findings and negative or equivocal roentgenograms following trauma. Bone scanning facilitated the prompt diagnosis of occult fractures in the hip, knee, wrist, ribs and costochondral junctions, sternum, vertebrae, sacrum, and coccyx. Several illustrative cases are presented. Roentgenographic confirmation occurred following a delay of days to weeks and, in some instances, the roentgenographic findings were subtle and could be easily overlooked. This study demonstrates bone scanning to be invaluable and definitive in the prompt detection of occult fractures.

  14. Detection of unsuspected malignant pleural effusion by bone scan

    SciTech Connect

    Goldstein, H.A.; Gefter, W.B.

    1984-10-01

    Technetium-99m phosphate compounds may occasionally accumulate in malignant pleural effusions. A case of metastatic pleural effusion first diagnosed by bone scan, prior to its clinical or roentgenographic detection, is reported.

  15. Does aspiration of bones and joints affect results of later bone scanning

    SciTech Connect

    Canale, S.T.; Harkness, R.M.; Thomas, P.A.; Massie, J.D.

    1985-01-01

    To determine the effect, if any, of needle aspiration on /sup 99m/Tc bone scanning, three different areas of 15 dogs were first aspirated and then imaged with technetium bone scintigraphy. The hip joint was aspirated, the distal femoral metaphysis was drilled and aspirated, and the tibial periosteum was scraped with an 18- or 20-gauge needle. Varying amounts of trauma were inflicted to simulate varying difficulties at aspiration. /sup 99m/Tc bone scans were obtained from 5 h to 10 days later. There was no evidence of focal technetium uptake after any hip joint aspiration. This was consistent regardless of the amount of trauma inflicted or the time from aspiration to bone scanning. Metaphyseal cortical drilling and tibial periosteal scraping occasionally caused some focal uptake when scanning was delayed greater than 2 days. When osteomyelitis or pyarthrosis is clinically suspected, joint aspiration can be performed without fear of producing a false- positive bone scan.

  16. [Scanning electron microscopy of heat-damaged bone tissue].

    PubMed

    Harsanyl, L

    1977-02-01

    Parts of diaphyses of bones were exposed to high temperature of 200-1300 degrees C. Damage to the bone tissue caused by the heat was investigated. The scanning electron microscopic picture seems to be characteristic of the temperature applied. When the bones heated to the high temperature of 700 degrees C characteristic changes appear on the periostal surface, higher temperatura on the other hand causes damage to the compact bone tissue and can be observed on the fracture-surface. Author stresses the importance of this technique in the legal medicine and anthropology.

  17. Reversal of drug-induced rhabdomyolysis on bone scan.

    PubMed

    Abrams, Joseph; Tiu, Serafin

    2011-08-01

    A 75-year-old man with prostate cancer was referred for metastatic workup. A Tc-99m methylene diphosphonate bone scan was performed which revealed diffusely increased radiopharmaceutical uptake in the muscles of the arms and thighs. The patient was taking simvastatin 80 mg per day and gemfibrozil 600 mg twice a day for high cholesterol. The patient reported myalgias, and laboratory evaluation was consistent with rhabdomyolysis. After discontinuation of the anticholesterol medications, the clinical and laboratory evaluations normalized. Bone scan performed 1 year later demonstrated complete resolution of muscle uptake.

  18. Confocal laser scanning microscopy in study of bone calcification

    NASA Astrophysics Data System (ADS)

    Nishikawa, Tetsunari; Kokubu, Mayu; Kato, Hirohito; Imai, Koichi; Tanaka, Akio

    2012-12-01

    Bone regeneration in mandible and maxillae after extraction of teeth or tumor resection and the use of rough surface implants in bone induction must be investigated to elucidate the mechanism of calcification. The calcified tissues are subjected to chemical decalcification or physical grinding to observe their microscopic features with light microscopy and transmission electron microscopy where the microscopic tissue morphology is significantly altered. We investigated the usefulness of confocal laser scanning microscopy (CLSM) for this purpose. After staggering the time of administration of calcein and alizarin red to experimental rats and dogs, rat alveolar bone and dog femur grafted with coral as scaffold or dental implants were observed with CLSM. In rat alveolar bone, the calcification of newly-formed bone and net-like canaliculi was observed at the mesial bone from the roots progressed at the rate of 15 μm/day. In dog femur grafted with coral, newly-formed bones along the space of coral were observed in an orderly manner. In dog femur with dental implants, after 8 weeks, newly-formed bone proceeded along the rough surface of the implants. CLSM produced high-magnification images of newly-formed bone and thin sections were not needed.

  19. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    NASA Astrophysics Data System (ADS)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  20. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound.

    PubMed

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R(2)=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R(2)=0.67) and BV/TV (R(2)=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R(2)=0.92 for BV/TV and R(2)=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  1. Metastatic calcification of the stomach imaged on a bone scan

    SciTech Connect

    Goldstein, R.; Ryo, U.Y.; Pinsky, S.M.

    1984-10-01

    A whole body bone scan obtained on a 21-year-old woman with sickle cell disease and chronic renal failure showed localization of the radionuclide diffusely in the stomach. The localization of the radionuclide represented metastatic calcification of the stomach caused by secondary hyperparathyroidism.

  2. Multifocal adamantinoma simulating traumatic pathology on bone scanning.

    PubMed

    Imran, Muhammad Babar; Naeem, Muhammad

    2013-02-01

    This is a case report of a young physically active patient who presented with pain in the right leg. Plain radiograph and bone scan showed lesions mimicking stress fracture. Follow-up investigations (repeated plain radiography and three phase bone scan) and histopathological examination proved it as a case of multifocal adamantinoma. This report signifies that physicians should not lock their mind only to one entity and keep the differential diagnosis list flexible especially if patient does not respond to a specific treatment. Tibial adamantinoma should also be considered in the differential diagnosis of stress fracture. Further, second lesion can occur in the rib cage defying the common belief that second lesion will be in the adjacent bone, fibula.

  3. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    PubMed Central

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2012-01-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone’s mechanical strength and structural parameters, i.e., bulk Young’s modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young’s modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone’s structural integrity. PMID:23976803

  4. A Preanalytic Validation Study of Automated Bone Scan Index: Effect on Accuracy and Reproducibility Due to the Procedural Variabilities in Bone Scan Image Acquisition.

    PubMed

    Anand, Aseem; Morris, Michael J; Kaboteh, Reza; Reza, Mariana; Trägårdh, Elin; Matsunaga, Naofumi; Edenbrandt, Lars; Bjartell, Anders; Larson, Steven M; Minarik, David

    2016-12-01

    The effect of the procedural variability in image acquisition on the quantitative assessment of bone scan is unknown. Here, we have developed and performed preanalytical studies to assess the impact of the variability in scanning speed and in vendor-specific γ-camera on reproducibility and accuracy of the automated bone scan index (BSI).

  5. Visualizing bone porosities using a tabletop scanning electron microscope

    NASA Astrophysics Data System (ADS)

    Krishnamoorthy, D.; DaPonte, J.; Broadbridge, C. C.; Daniel, D.; Alter, L.

    2010-04-01

    Pores are naturally occurring entities in bone. Changes in pore size and number are often associated with diseases such as Osteoporosis and even microgravity during spaceflight. Studying bone perforations may yield great insight into bone's material properties, including bone density and may contribute to identifying therapies to halt or potentially reverse bone loss. Current technologies used in this field include nuclear magnetic resonance, micro-computed tomography and the field emission scanning electron microscope (FE-SEM) 2, 5. However, limitations in each method limit further advancement. The objective of this study was to assess the effectiveness of using a new generation of analytical instruments, the TM-1000 tabletop, SEM with back-scatter electron (BSE) detector, to analyze cortical bone porosities. Hind limb unloaded and age-based controlled mouse femurs were extracted and tested in vitro for changes in pores on the periosteal surface. An important advantage of using the tabletop is the simplified sample preparation that excludes extra coatings, dehydration and fixation steps that are otherwise required for conventional SEM. For quantitative data, pores were treated as particles in order to use an analyze particles feature in the NIH ImageJ software. Several image-processing techniques for background smoothing, thresholding and filtering were employed to produce a binary image suitable for particle analysis. It was hypothesized that the unloaded bones would show an increase in pore area, as the lack of mechanical loading would affect bone-remodeling processes taking place in and around pores. Preliminary results suggest only a slight different in frequency but not in size of pores between unloaded and control femurs.

  6. Bone and gallium scans in mastocytosis: correlation with count rates, radiography, and microscopy

    SciTech Connect

    Ensslen, R.D.; Jackson, F.I.; Reid, A.M.

    1983-07-01

    Mastocytosis (urticaria pigmentosa) was proven in a patient suffering from severe back pain. A bone scan showed diffusely increased bone activity. Count rates were also abnormally elevated over several areas of the skeleton. Radiographs were consistent with mastocytosis in bone.

  7. Os trigonum syndrome: use of bone scan in the diagnosis

    SciTech Connect

    Johnson, R.P.; Collier, B.D.; Carrera, G.F.

    1984-08-01

    The os trigonum is an accessory bone of the foot found in 7% of the normal adult population. It is located at the posterolateral projection of the talus, and can occasionally give rise to symptoms of acute and chronic unexplained ankle pain. We report three patients, one with acute fracture and two with chronic ankle symptoms. Technetium 99 methylene diphosphonate showed intense focal uptake at the posterior talus pointing to the os trigonum as the site of symptoms. It was excised in two patients with complete relief. The third went on to develop an asymptomatic nonunion. We recommend bone scanning as a procedure that is helpful in delineating obscure pain in the ankle that may be due to chronic irritative nonunion of the os trigonum.

  8. Staging of renal cell carcinoma: cost-effectiveness of routine preoperative bone scans

    SciTech Connect

    Campbell, R.J.; Broaddus, S.B.; Leadbetter, G.W. Jr.

    1985-03-01

    The use of bone scans in the evaluation of renal cell carcinoma has become routine in many centers. In a retrospective analysis of 42 patients undergoing radical nephrectomy for renal cell carcinoma, the authors analyzed the cost-effectiveness of routine preoperative bone scans. Although these scans accurately predict metastatic disease to bone, they are not cost-effective as a routine preoperative tool because they do not alter outcome. In selected patients with bone pain and no other positive staging studies, preoperative bone scans may be of value in the decision to perform extirpative surgery.

  9. Benign Brenner tumor of the ovary detected on Tc-99m methylene diphosphonate bone scan

    SciTech Connect

    Renner, J.B.; McCartney, W.H.

    1984-11-01

    Many disease states, including neoplasia, have been detected by bone scanning. Among the neoplastic processes detected by bone imaging agents are ovarian tumors, both benign and malignant. This report is concerned with the visualization of a benign Brenner tumor during routine Tc-99m MDP bone scanning.

  10. Three phase bone scan interpretation based upon vascular endothelial response

    PubMed Central

    Kumar, Kush

    2015-01-01

    Objectives: A new method of interpretation of Three Phase Bone Scan (TPBS) scan based upon the normal physiological vascular endothelial related response. Materials and Methods: Fifty cases of TPBS were evaluated. Thirteen were normal. In remaining 37 positive studies, 20 showed localized hyperemic response. All localized hyperemic responses except one with vascular endothelial dysfunction were without infection (95.0%). Infection could be ruled out in absence of generalized massive flow and pool response. All 17 cases with generalized massive hyperemic response had infection, consistent with infection or CRPS/RSD. Micro-bacterial or histological confirmation of infection was obtained in 11 cases. All 11 cases with confirmed infection showed generalized massive hyperemic response (100.0%). Two were CRPS/RSD and 2 cases were of cellulitis (100.0%). Among remaining 2, one refused surgery and other was lost to follow-up. Additionally, 20 published cases in the literature of osteomyelitis were also analyzed. Nineteen cases of bone and joint infection, (osteomyelitis/arthritis/cellulitis) except one with endothelial dysfunction showed generalized massive increased flow and pool response (95.0%). All published cases of osteomyelitis in the literature showed generalized massive hyperemic response (100.0%). Results: The data clearly indicated that 100% of the cases of bone infection (osteomyelitis/arthritis/cellulitis) and cases of CRPS/RSD showed generalized massive flow and pool pattern. Infection could be ruled out in absence of generalized massive flow and pool response. All 100% published cases of osteomyelitis in the literature showed positive vascular endothelial response. Conclusion: By incorporating the concept of vascular endothelial related response causing massive vasodilatation in infection, the interpretation of the TPBS can be more précised as it is based upon the normal physiology. Larger studies are recommended. PMID:25829726

  11. Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

    SciTech Connect

    Falchook, Aaron D.; Salloum, Ramzi G.; Hendrix, Laura H.; Chen, Ronald C.

    2014-06-01

    Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

  12. Scanning electron microscopy of human cortical bone failure surfaces.

    PubMed

    Braidotti, P; Branca, F P; Stagni, L

    1997-02-01

    Undecalcified samples extracted from human femoral shafts are fractured by bending and the fracture surfaces are examined with a scanning electron microscope (SEM). The investigation is performed on both dry and wet (hydrated with a saline solution) specimens. SEM micrographs show patterns in many respects similar to those observed in fractography studies of laminated fiber-reinforced synthetic composites. In particular, dry and wet samples behave like brittle and ductile matrix laminates, respectively. An analysis carried out on the basis of the mechanisms that dominate the fracture process of laminates shows that a reasonable cortical bone model is that of a laminated composite material whose matrix is composed of extracellular noncollagenous calcified proteins, and the reinforcement is constituted by the calcified collagen fiber system.

  13. Radionuclide bone scanning in females with chronic low back pain.

    PubMed Central

    Rothwell, R S; Davis, P; Lentle, B C

    1981-01-01

    Sixty female patients with chronic low back pain have been studied clinically, radiographically, and by radionuclide bone scanning for evidence of sacroiliac disease. Twenty-four patients had quantitative sacroiliac scintigraphy (QSS) results suggesting sacroiliitis. In only one of these patients was the radiograph abnormal. Clinical and laboratory examinations failed to reveal any possible associated aetiological factors. Six-month follow-up of 18 patients showed that subjective improvement of pain is associated with a return to normal of QSS results, often secondary to anti-inflammatory medication. It is concluded that sacroiliac disease may be a common cause for chronic low back pain in women and that its presence may be missed if radiographs are relied upon to confirm the diagnosis. Its aetiology remains obscure. PMID:6451204

  14. Bone scans after total knee arthroplasty in asymptomatic patients. Cemented versus cementless

    SciTech Connect

    Hofmann, A.A.; Wyatt, R.W.; Daniels, A.U.; Armstrong, L.; Alazraki, N.; Taylor, A. Jr. )

    1990-02-01

    The natural history of bone scans after total knee arthroplasty (TKA) was studied in 26 patients with 28 cemented TKAs and 29 patients with 31 cementless TKAs. The bone scans were examined at specified postoperative intervals. Radionuclide activity of the femoral, tibial, and patellar regions was measured. Six patients who developed pain postoperatively were excluded. Bone scans immediately postoperative and at three months demonstrated increased uptake, which gradually decreased to baseline levels at ten to 12 months. Radioisotope uptake was comparable in the cemented and cementless groups, but was highly variable in individual patients and in each of the follow-up periods. A single postoperative bone scan cannot differentiate component loosening from early bone remodeling. Sequential bone scans, as a supplement to the clinical examination and conventional radiography, may prove useful in the diagnosis of TKA failure.

  15. Co-registration of isotope bone scan with CT scan and MRI in the investigation of spinal pathology.

    PubMed

    Brazenor, Graeme A; Malham, Gregory M; Ballok, Zita E

    2014-09-01

    Image fusion software enables technetium(99m)-methylene diphosphonate (Tc(99m)-MDP) bone scan images to be co-registered with CT scan or MRI, allowing greater anatomical discrimination. We examined the role of bone scan images co-registered with CT scan or MRI in the investigation of patients presenting with axial spinal pain and/or limb pain. One hundred and thirty-nine consecutive patients were examined, and thereafter investigated with CT scan, MRI, and/or dynamic plain films. At this point diagnosis (pathology type and anatomical site) and treatment intention were declared. The co-registered Tc(99m)-MDP bone scan images were then studied, after which diagnosis (pathology type and anatomical site) and treatment intention were re-declared. This data were then analysed to determine whether the addition of co-registered bone scan images resulted in any change in diagnosis or treatment intention. The most significant change in diagnosis was pathology type (10%). Anatomical site changed markedly without overlap of the pre and post-isotope fields in 5%, and with overlap in 10%. Treatment intention had a major change in 3.6% and minor change in 8.6%. In the two groups where there was (i) no obvious pathology after full pre-isotope investigation, or (ii) a spinal fusion under suspicion, addition of the bone scan information led to a major change in the pathology and/or anatomical localisation in 18% and 19%, respectively. The addition of co-registered Tc(99m)-MDP bone scan images offers significant diagnostic assistance, particularly in the difficult diagnostic groups where a failed spinal fusion may be the suspected pain generator, or when no pain generator can otherwise be found.

  16. Growth plate closure: Apex view on bone scan

    SciTech Connect

    Giles, P.H.; Trochei, M.; Yeates, K.

    1984-01-01

    Angular deformities of the extremities in children following premature closure of the growth plate are well known. The deformities depend on the position of an osseus bridge which forms between the epiphysis and metaphysis. Several surgical procedures including resection of the osseus bridge have been described, however, delineation of the site of fusion is difficult to define. The commonest site of growth plate arrest is the distal femoral or proximal tibial growth plate. A new technique using the bone scan has been developed which accurately defines the area and position of these osseus bridges. Two hours after injection of technetium 99m methylene diphosphonate apex views of the affected distal femoral growth plate were performed. The knee was flexed into its smallest angle. Using a pinhole collimator the gamma camera was angled to face the affected growth plate end on. The image was collected onto computer and analysed by: (I) regions of interest over segments of the growth plate to calculate the relative area of total growth plate affected: (II) generating histograms: (III) thresholding or performing isocontours to accentuate abnormal areas. The growth plate is normally uniformly increased when compared to the normal shaft of the bone. Fusion across the plate appears as an area of diminished uptake. The apex view gives a unique functional map of the growth plate such that abnormal areas are displayed, and the site, size and position of osseus fusion obtained. The technique has the potential for determining the metabolic activity of the growth plate before and after surgery. Serial studies will allow assessment of regneration of the plate and reformation of new osseus bridges.

  17. [Differential diagnosis of reduced uptake images revealed by bone scan: about a case of acute lymphoblastic leukemia].

    PubMed

    Bahadi, Nisrine; Biyi, Abdelhamid; Oueriagli, Salah Nabih; Doudouh, Abderrahim

    2016-01-01

    If increased uptake during bone scan usually bring to light many bone pathologies, reduced uptakes are a rare occurrence and they require careful analysis to avoid erroneous interpretations. We report the case of a 17-year old admitted with diffuse bone pain, hypercalcemia and thrombopenia. Bone scan showed areas of low uptakes. Bone marrow tests allowed the diagnosis of acute lymphoblastic leukemia. This case report aims to discuss the main differential diagnoses based on such bone scan abnormalities.

  18. Role of bone and liver scans in surveying patients with breast cancer for metastatic disease

    SciTech Connect

    Evans, D.M.; Wright, D.J.

    1987-10-01

    The objective of this study is to correlate the presence of bone and liver metastases in patients with breast cancer with respect to the results of bone and liver scans, axillary nodal status, and serum alkaline phosphatase levels. One hundred ninety-seven patients with breast cancer treated by modified radical mastectomy between the years 1978 and 1981 were studied. Fifty-nine (30%) of the total group had distant metastases during the course of observation of 60 to 96 months; of 35 patients in whom bone metastases developed, 30 had normal preoperative bone scan results. Of 21 patients who had liver metastases, 19 had normal preoperative liver scans. Nineteen (70%) of the 27 patients with abnormal bone scans had normal alkaline phosphatase levels. Seven (63%) of the 11 patients who had abnormal liver scans had a normal alkaline phosphatase. The study supports the concept that preoperative bone and liver scans are ineffective indicators of metastatic involvement. Selection of patients for screening by bone and liver scans according to alkaline phosphatase determinations was not supported by this study. The appropriate use of bone scans for screening in patients with breast carcinoma is suggested as a follow-up device in patients with positive lymph nodes.

  19. Childhood acute lymphoblastic leukemia presenting as ''cold'' lesions on bone scan: a report of two cases

    SciTech Connect

    Caudle, R.J.; Crawford, A.H.; Gelfand, M.J.; Gruppo, R.A.

    1987-01-01

    ''Cold'' lesions on bone scan have been reported in a variety of disease processes, including infection, avascular necrosis, and cysts. We present two cases of children who presented with large ''cold'' areas on technetium bone scans and were treated initially for septic processes. Acute childhood leukemia frequently presents with bone or joint pain, fever, and elevation of the erythrocyte sedimentation rate. Although the diagnosis may be difficult if the characteristic clinical signs and laboratory findings are absent, the presence of anemia should alert the physician to the possibility of malignancy. Bone scanning provides a sensitive method of localizing pathology, but diagnosis requires biopsy or marrow aspiration.

  20. Prostate Cancer With Metastatic Lytic Bone Lesions: Positive Bone Scan Post Docetaxel Chemotherapy in the Setting of Clinically Successful Treatment

    PubMed Central

    Bird, Victoria Yvonne; Domino, Paula M.; Sutkowski, Raymond; Stillings, Stephanie A.; Trejo-Lopez, Jorge A.

    2016-01-01

    Current treatment of metastatic bone prostate cancer with Docetaxel chemotherapy per CHAARTED trial is standard of care. Timing of CT and bone scintigraphy for evaluation of successful treatment of lytic lesions is not available in the literature. We present a case of a 70 year old male with PSA of 586 and wide spread metastatic bone lytic lesions, who underwent androgen deprivation therapy and six cycles of Docetaxel chemotherapy. The patient had clinically successful treatment. Contrast enhanced CT scan demonstrated sclerotic bone lesions with PSA 2.5 at this point in treatment; however, 99mTc-MDP bone scintigraphy remained positive for metastatic lesions. PMID:27169018

  1. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    SciTech Connect

    Sundberg, S.B.; Savage, J.P.; Foster, B.K. )

    1989-09-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis.

  2. A rare variant of Caffey's disease - X-rays, bone scan and FDG PET findings.

    PubMed

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2011-04-01

    An 18-month-old boy with history of fever of 4 months duration and with swelling of the limbs was referred for a bone scan. There were multiple swellings over his upper and lower limbs, with bowing of the lower limbs. His radiological skeletal survey revealed marked periosteal new bone formation surrounding the diaphysis of long bones. A bone scan done with 99m Tc-MDP showed diffusely increased tracer uptake in all the long bones. A fluorodeoxyglucose positron emission tomography (FDG PET) scan done to assess the metabolic activity showed patchy FDG uptake in the long bones, ankle joint and anterior ends of few ribs. His clinical and imaging findings led to the diagnosis of Caffey's disease.

  3. Preliminary results of automated removal of degenerative joint disease in bone scan lesion segmentation

    NASA Astrophysics Data System (ADS)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Auerbach, Martin; Goldin, Jonathan; Henkel, Keith; Banola, Ashley; Morris, Darren; Coy, Heidi; Brown, Matthew S.

    2013-03-01

    Whole-body bone scintigraphy (or bone scan) is a highly sensitive method for visualizing bone metastases and is the accepted standard imaging modality for detection of metastases and assessment of treatment outcomes. The development of a quantitative biomarker using computer-aided detection on bone scans for treatment response assessment may have a significant impact on the evaluation of novel oncologic drugs directed at bone metastases. One of the challenges to lesion segmentation on bone scans is the non-specificity of the radiotracer, manifesting as high activity related to non-malignant processes like degenerative joint disease, sinuses, kidneys, thyroid and bladder. In this paper, we developed an automated bone scan lesion segmentation method that implements intensity normalization, a two-threshold model, and automated detection and removal of areas consistent with non-malignant processes from the segmentation. The two-threshold model serves to account for outlier bone scans with elevated and diffuse intensity distributions. Parameters to remove degenerative joint disease were trained using a multi-start Nelder-Mead simplex optimization scheme. The segmentation reference standard was constructed manually by a panel of physicians. We compared the performance of the proposed method against a previously published method. The results of a two-fold cross validation show that the overlap ratio improved in 67.0% of scans, with an average improvement of 5.1% points.

  4. The lateral distal femoral DEXA scan in children: a chronology of growing bone?

    PubMed

    Tryon, Elyce; Szalay, Elizabeth A

    2008-11-01

    Dual energy x-ray absorptiometry (DEXA) is the current standard for measuring bone mineral density (BMD) in children. The International Society for Clinical Densitometry recommends scanning the total body and spine in children. However, in orthopedics, the total-body and spine DEXA scans are often rendered useless by the presence of metallic hardware and/or contractures. The lateral distal femoral DEXA scan was developed as a scan mode for children such as those with cerebral palsy who have contractures or metallic implants, which make it impossible to do total-body or spine scans. Unlike other DEXA scans, a single scan of the lateral distal femoral illustrates the density of the metaphyseal cancellous (newer) bone, the transitional, and the cortical (older) bone in 1 image. Because of this, we hypothesized that an individual lateral distal femoral scan could provide a map of bone health over time. The lateral distal femoral scans of 40 children whose bone growth was tainted by distant chemotherapy (chemotherapy group) were compared to the lateral distal femoral scans of 40 children whose bone environment had remained relatively stable over time (control group). The hypothesis was not confirmed by the data. The "Z-score difference," the difference between the Z-scores of the cancellous and cortical bone, for the chemotherapy group (0.16) and the control group (0.32) were not statistically different. While these results did not confirm the hypothesis, the lateral distal femoral scan remains a reproducible and useful DEXA scan in pediatric orthopedic clinical practice.

  5. Automated segmentation of tumors on bone scans using anatomy-specific thresholding

    NASA Astrophysics Data System (ADS)

    Chu, Gregory H.; Lo, Pechin; Kim, Hyun J.; Lu, Peiyun; Ramakrishna, Bharath; Gjertson, David; Poon, Cheryce; Auerbach, Martin; Goldin, Jonathan; Brown, Matthew S.

    2012-03-01

    Quantification of overall tumor area on bone scans may be a potential biomarker for treatment response assessment and has, to date, not been investigated. Segmentation of bone metastases on bone scans is a fundamental step for this response marker. In this paper, we propose a fully automated computerized method for the segmentation of bone metastases on bone scans, taking into account characteristics of different anatomic regions. A scan is first segmented into anatomic regions via an atlas-based segmentation procedure, which involves non-rigidly registering a labeled atlas scan to the patient scan. Next, an intensity normalization method is applied to account for varying levels of radiotracer dosing levels and scan timing. Lastly, lesions are segmented via anatomic regionspecific intensity thresholding. Thresholds are chosen by receiver operating characteristic (ROC) curve analysis against manual contouring by board certified nuclear medicine physicians. A leave-one-out cross validation of our method on a set of 39 bone scans with metastases marked by 2 board-certified nuclear medicine physicians yielded a median sensitivity of 95.5%, and specificity of 93.9%. Our method was compared with a global intensity thresholding method. The results show a comparable sensitivity and significantly improved overall specificity, with a p-value of 0.0069.

  6. Role of nuclear medicine bone scans in evaluating pain in athletic injuries

    SciTech Connect

    Martire, J.R.

    1987-10-01

    The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

  7. Resolution recovery in planar bone scans: diagnostic value in metastatic disease.

    PubMed

    Grüning, Thomas; Brogsitter, Claudia; Jones, Ivor W; Heales, Jason C

    2012-12-01

    Recovery of spatial resolution lost through increasing lesion-to-detector distance can improve the spatial resolution of planar images. We compare two commercial solutions, HiScan (http://www.scivis.de) and Xact.bone (http://www.ultraspect.com), with unprocessed planar whole-body bone scans. Thirty-five patients with suspected bone metastases were scanned 3 h after injection of 600 MBq (99m)Tc-HMDP at 12 cm/min. Two patients with more than 20 lesions were used for reporter training and were excluded from the analysis. Two blinded reporters categorized each scan as benign, indeterminate or malignant and assigned individual lesions to those same categories. Image quality was first graded on a 1 (worst) to 10 (best) scale for each individual scan, and then all three scans of each patient were ranked according to image quality. Reporter A detected 65, 90 and 83 malignant lesions with the unprocessed scan, HiScan and Xact.bone and 23, 24 and 17 indeterminate lesions, respectively. Reporter B detected 60, 80 and 75 malignant lesions with the unprocessed scan, HiScan and Xact.bone and 17, 16 and 14 indeterminate lesions, respectively. To summarize, reporters A/B detected 38/33% and 28/25% more malignant lesions with HiScan and Xact.bone than with the unprocessed scan, respectively (Friedman's test, P<0.05). The number of indeterminate lesions did not increase, but the percentage of unclear lesions decreased. Mean image quality for the unprocessed scan, HiScan and Xact.bone was 6.5, 9.1 and 7.9 for reporter A and 5.6, 7.5 and 6.7 for reporter B, respectively (P<0.0001). HiScan was ranked best for image quality in 82% of patients and Xact.bone in 18%. Resolution recovery in planar whole-body bone scans significantly increases the absolute number of detectable malignant lesions, decreases the percentage of indeterminate lesions, significantly increases image quality and is an easy-to-implement addition to routine clinical practice.

  8. Computer-aided quantitative bone scan assessment of prostate cancer treatment response

    PubMed Central

    Brown, Matthew S.; Chu, Gregory H.; Kim, Hyun J.; Allen-Auerbach, Martin; Poon, Cheryce; Bridges, Juliette; Vidovic, Adria; Ramakrishna, Bharath; Ho, Judy; Morris, Michael J.; Larson, Steven M.; Scher, Howard I.; Goldin, Jonathan G.

    2012-01-01

    Objective The development and evaluation of a computer-aided bone scan analysis technique to quantify changes in tumor burden and assess treatment effects in prostate cancer clinical trials. Methods We have developed and report on a commercial fully automated computer-aided detection system. Using this system, scan images were intensity normalized, then lesions identified and segmented by anatomic region-specific intensity thresholding. Detected lesions were compared against expert markings to assess the accuracy of the computer-aided detection system. The metrics Bone Scan Lesion Area, Bone Scan Lesion Intensity, and Bone Scan Lesion Count were calculated from identified lesions, and their utility in assessing treatment effects was evaluated by analyzing before and after scans from metastatic castration-resistant prostate cancer patients: 10 treated and 10 untreated. In this study, patients were treated with cabozantinib, a MET/VEGF inhibitor resulting in high rates of resolution of bone scan abnormalities. Results Our automated computer-aided detection system identified bone lesion pixels with 94% sensitivity, 89% specificity, and 89% accuracy. Significant differences in changes from baseline were found between treated and untreated groups in all assessed measurements derived by our system. The most significant measure, Bone Scan Lesion Area, showed a median (interquartile range) change from baseline at week 6 of 7.13% (27.61) in the untreated group compared with −73.76% (45.38) in the cabozantinib-treated group (P = 0.0003). Conclusions Our system accurately and objectively identified and quantified metastases in bone scans, allowing for interpatient and intrapatient comparison. It demonstrates potential as an objective measurement of treatment effects, laying the foundation for validation against other clinically relevant outcome measures. PMID:22367858

  9. Two unusual causes of peripatellar nonmetastatic positive bone scans in patients with malignancies: case reports.

    PubMed

    Turner, J W; Syed, I B; Spencer, R P

    1976-08-01

    Bone scans performed with 99mTc-polyphosphate in two patients with epidermoid carcinoma of the lung each showed activity in one knee area. In the first case, radiographs of the area revealed Pellegrini-Stieda calcification over the internal femoral condyle. Uptake corresponded to this process, rather than to a lesion deep in the bone. In the second case, the activity accumulation in the right tibia was the only abnormality noted in the scan. An open biopsy revealed Paget's disease, and no radiographic evidence of Paget's disease was found in any other bone. These cases again illustrate that localized accumulation of a bone-scanning agent, in patients with known primary tumors, does not necessarily denote malignancy in bone.

  10. Scanning electron microscopy analysis of experimental bone hacking trauma of the mandible.

    PubMed

    Alunni-Perret, Véronique; Borg, Cybèle; Laugier, Jean-Pierre; Bertrand, Marie-France; Staccini, Pascal; Bolla, Marc; Quatrehomme, Gérald; Muller-Bolla, Michèle

    2010-12-01

    The authors report on a macroscopic and microscopic study of human mandible bone lesions achieved by a single-blade knife and a hatchet. The aim of this work was to complete the previous data (scanning electron microscopy analysis of bone lesions made by a single-blade knife and a hatchet, on human femurs) and to compare the lesions of the femur with those of the mandible. The results indicate that the mandible is a more fragile bone, but the features observed on the mandible are quite similar to those previously observed on the femur. This work spells out the main scanning electron microscopy characteristics of sharp (bone cutting) and blunt (exerting a pressure on the bone) mechanisms on human bone. Weapon characteristics serve to explain all of these features.

  11. Incidental detection of pericardial effusion on bone scan.

    PubMed

    Unal, Kemal; Unlu, Mustafa; Guner, Levent

    2013-01-01

    The patient was a 57-year-old man with lung cancer. He was referred to nuclear medicine department for the evaluation of bone metastases. Bone scintigraphy was performed with 99mTc-labeled HDP. An abnormal photopenic area around the heart was seen on blood pool images. Delayed image of the thorax was normal. Chest x-ray study and echocardiography were performed to reveal the abnormality. Asymptomatic pericardial effusion was diagnosed in the corresponding area.

  12. Reversible bone pain and symmetric bone scan uptake in a dialysis patient treated with cinacalcet: a case report

    PubMed Central

    2010-01-01

    Introduction The medical management of secondary hyperparathyroidism in patients with end-stage renal disease involves a combination of dietary restrictions, phosphate binders, active vitamin D analogs, and calcimimetics. Case presentation We report the case of a 36-year-old Hispanic dialysis patient, originally from Cuba and now residing in the USA, who developed severe bone pain and muscle twitching after starting low dose cinacalcet, despite normal pre-dialysis ionized calcium and elevated parathyroid hormone. The clinical symptoms correlated with increased symmetrical uptake on bone scan that resolved rapidly upon discontinuation of cinacalcet. Conclusion Cinacalcet may induce severe bone pain and a unique bone scan uptake pattern in hemodialysis patients. PMID:20576153

  13. Radionuclide bone scan, radiographic bone survey, and alkaline phosphatase: studies of limited value in asymptomatic patients with ovarian carcinoma

    SciTech Connect

    Metler, F.A. Jr.; Christie, J.H.; Crow, N.E. Jr.; Garcia, J.F.; Wicks, J.D.; Bartow, S.A.

    1982-10-15

    Bone scans or skeletal surveys were obtained in 104 patients with ovarian carcinoma. No metastases were identified at staging in the 43 patients with Stage I or II disease. Four patients in the entire series had osseous metastases. Three of the 40 patients with Stage III epithelian ovarian carcinoma has osseous metastases at the time of staging. All of these were Grade III lesions. One Stage I, Grade III patient demonstrated osseous metastases two years after initial diagnosis. None of the four patients with osseous metastases had an elevated alkaline phosphatase; three of the four had bone pain. Based on these results, it is suggested that radiographic bone survey and radionuclide bone scans are not indicated as screening procedures in asymptomatic patients with ovarian carcinoma.

  14. Fully automated shape model positioning for bone segmentation in whole-body CT scans

    NASA Astrophysics Data System (ADS)

    Fränzle, A.; Sumkauskaite, M.; Hillengass, J.; Bäuerle, T.; Bendl, R.

    2014-03-01

    Analysing osteolytic and osteoblastic bone lesions in systematically affected skeletons, e.g. in multiple myeloma or bone metastasis, is a complex task. Quantification of the degree of bone destruction needs segmentation of all lesions but cannot be managed manually. Automatic bone lesion detection is necessary. Our future objective is comparing modified bones with healthy shape models. For applying model based strategies successfully, identification and position information of single bones is necessary. A solution to these requirements based on bone medullary cavities is presented in this paper. Medullary cavities are useful for shape model positioning since they have similar position and orientation as the bone itself but can be separated more easily. Skeleton segmentation is done by simple thresholding. Inside the skeleton medullary cavities are segmented by a flood filling algorithm. The filled regions are considered as medullary cavity objects. To provide automatic shape model selection, medullary cavity objects are assigned to bone structures with pattern recognition. To get a good starting position for shape models, principal component analysis of medullary cavities is performed. Bone identification was tested on 14 whole-body low-dose CT scans of multiple myeloma patients. Random forest classification assigns medullary cavities of long bones to the corresponding bone (overall accuracy 90%). Centroid and first principal component of medullary cavity are sufficiently similar to those of bone (mean centroid difference 21.7 mm, mean difference angle 1.54° for all long bones of one example patient) and therefore suitable for shape model initialization. This method enables locating long bone structures in whole-body CT scans and provides useful information for a reasonable shape model initialization.

  15. Computer-assisted quantitative evaluation of bisphosphonate treatment for Paget's disease of bone using the bone scan index

    PubMed Central

    Nagano, Satoshi; Nakamura, Shunsuke; Shimada, Hirofumi; Yokouchi, Masahiro; Setoguchi, Takao; Ishidou, Yasuhiro; Sasaki, Hiromi; Komiya, Setsuro

    2016-01-01

    The purpose of the present study was to analyze the effect of treatment of Paget's disease of bone (PDB) with bone scintigraphy using a computer-assisted diagnosis system (BONENAVI) that quantitatively evaluates bone metabolism. Seven patients with PDB (three male, four female; average age, 60 years; age range, 33–80 years) underwent bone scintigraphy and measurement of serum alkaline phosphatase (ALP), bone-specific ALP (BAP), serum cross-linked N-telopeptide (NTx) of type I collagen, urinary NTx, and deoxypyridinoline (DPD) before and after bisphosphonate treatment. Bone scan index (BSI), artificial neural network (ANN) value, and hotspot number (HSn) were calculated using BONENAVI software. Mean follow-up period was 22 months (range, 11–35 months). Among three BONENAVI parameters (ANN, BSI, and HSn), only BSI was significantly lower after bisphosphonate treatment as compared with before. All bone metabolic markers excluding DPD were significantly lower following bisphosphonate treatment than before. Bone formation markers (ALP and BAP) were significantly lower than bone resorption markers (U-NTx and S-NTx). The correlation of BONENAVI parameters with four bone metabolic markers was analyzed before and after bisphosphonate treatment. Before treatment, the majority of the four markers did not correlate with the BONENAVI parameters. In contrast, post-treatment ALP, BAP, and U-NTx were significantly correlated with BSI and HSn. To the best of our knowledge, this is the first study to evaluate the treatment of PDB by bone scintigraphy using a computer-assisted diagnosis system that quantitatively evaluates bone metabolism. The findings demonstrated that, using BONENAVI software, bone scintigraphy is able to quantitatively and spatially evaluate the bisphosphonate treatment effect, particularly in patients with polyostotic PDB. PMID:28105116

  16. The effect of iron on the biodistribution of bone scanning agents in humans

    SciTech Connect

    Choy, D.; Murray, I.P.; Hoschl, R.

    1981-07-01

    Nine patients with chronic iron overload, resulting from either repeated transfusions or hemochromatosis, had bone scans that were characterized by a reduction of bony uptake, marked increase in renal activity, and a significant increase in soft-tissue accumulation of 99mTc-labeled bone-seeking agents. These findings were supported by semiquantitative computer analysis. The probable mechanisms of altered biodistribution and the possible role of serum ferritin are discussed. The importance of realizing the effect of excess iron on skeletal scintigraphy is further emphasized by the results of bone scanning in another patient in whom acute iron overload following infusion of iron-dextran resulted in excessive blood pool labeling.

  17. Effectiveness of bone scans in the diagnosis of osteoarthritis of the temporomandibular joint

    PubMed Central

    Kim, J-H; Kim, Y-K; Kim, S-G; Yun, P-Y; Kim, J-D; Min, J-H

    2012-01-01

    Objective The objective of this study was to evaluate the usefulness of bone scan procedures for the diagnosis of temporomandibular joint (TMJ) osteoarthritis. Methods From February 2009 to June 2009, 22 patients (4 males and 18 females) from Seoul National University Bundang Hospital, Republic of Korea, were diagnosed with TMJ disorder. They were examined by clinical examination, plain radiograph and bone scan and were categorized into three groups: normal, internal derangement and osteoarthritis. TMJ uptake ratios and asymmetrical indices were calculated. Results There were no significant differences in uptake ratios associated with pain and bone change. However, significant results were obtained when comparing uptake ratios between the osteoarthritis and non-osteoarthritis groups. Conclusion It was concluded from this study that bone scans may help to diagnose osteoarthritis when increased uptake ratios are observed. PMID:22116124

  18. Technetium 99m-methylene diphosphonate bone scans in children with reflex neurovascular dystrophy

    SciTech Connect

    Laxer, R.M.; Allen, R.C.; Malleson, P.N.; Morrison, R.T.; Petty, R.E.

    1985-03-01

    Eleven children with reflex neurovascular dystrophy were investigated by technetium-labeled methylene diphosphonate bone scanning. Eight of 12 scans demonstrated abnormal findings, four showing diffusely decreased uptake and four diffusely increased uptake of the radionuclide in the affected site. Three scans showed normal findings initially, as did one previously abnormal scan when repeated in the asymptomatic patient 6 months later. Diffusely abnormal findings can be helpful in the diagnosis of childhood reflex neurovascular dystrophy, but a normal scan does not exclude the diagnosis.

  19. Elevated soft tissue activity in early but not delayed phase of bone scan in Klippel-Trenaunay syndrome.

    PubMed

    Liu, Bin; Servaes, Sabah; Zhuang, Hongming

    2013-03-01

    Triple-phase bone scan is commonly used in the diagnosis of osteomyelitis. Elevated bone tracer activity in early but not delayed phase of the study favors cellulitis over osteomyelitis. We reported that Klippel-Trenaunay syndrome, a congenital disorder characterized by malformations of the capillary, venous, and lymphatic systems, can have images similar to cellulitis on triple-phase bone scan.

  20. Technetium Tc 99m diphosphonate bone scan. False-normal findings in elderly patients with hematogenous vertebral osteomyelitis

    SciTech Connect

    Schlaeffer, F.; Mikolich, D.J.; Mates, S.M.

    1987-11-01

    Hematogenous osteomyelitis is usually diagnosed by an abnormal technetium Tc 99m diphosphonate bone scan in symptomatic patients who have positive blood cultures. False-normal 99mTc bone scans have been described recently in neonates with biopsy-proved osteomyelitis. This phenomenon seems to be extremely rare in adults. Two elderly patients with hematogenous vertebral osteomyelitis had normal technetium Tc 99m diphosphonate bone scans when first evaluated. In both cases the bone scans became abnormal four to six weeks after onset of symptoms and two to four weeks after the initial normal results of the study. When suggested by the clinical picture, hematogenous osteomyelitis cannot be ruled out by a normal 99mTc bone scan at any age. Gallium scan, computed tomographic scan, or bone biopsy can be helpful in such cases.

  1. The use of dynamic bone scanning in the evaluation of wrist and hand pain

    SciTech Connect

    Gandsman, E.J.; Deutsch, S.D.; Catalozzi, K.; Herndon, J.

    1984-01-01

    Twenty-seven patients with complaints of wrist and/or hand pain were evaluated using a quantitative technique of dynamic (blood flow analysis) and static bone scan. The patients were divided in two groups according to their clinical history. Group A included 13 patients with a history of trauma. Seven patients had scaphoid fracture and 6 of them were scanned to determine non-union and/or avascular necrosis of the joint. One patient was scanned to determine the viability of a graft for non-union fracture. In all cases the scan gave a correct diagnosis as confirmed by later x-ray changes. Six patients in this group had negative x-rays. The scan demonstrated 4 cases of occult fractures, 4 had early Kienbock's Disease (KD) and 1 a soft tissue tumor. Group B included 14 patients with no known history of trauma. Nine had positive x-rays including 3 with KD that were scanned to determine their viability for surgical replacement of the lunate. The scan could distinguish between isolated involvement of the lunate and secondary degenerative changes of the surrounding carpal bones and radiocarpal joint. Two patients with tumor were correctly diagnosed by the scan, one as benign and one malignant. Four other patients with nonspecific changes on x-ray showed early arthritis (3 cases) and a cyst of the triquetrum ( 1 case) on the bone scan. Four patients in Group B had negative x-rays and the scan showed degenerative changes (3 cases) and an occult fracture of the hamate (1 case). The use of dynamic and static bone scanning appears to be a very valuable technique in the evaluation of patients with wrist and hand pain.

  2. MRI findings of new uptake in the femoral head detected on follow-up bone scans.

    PubMed

    Kim, Seong Ho; Yoo, Hye Jin; Kang, Yusuhn; Choi, Ja-Young; Hong, Sung Hwan

    2015-03-01

    OBJECTIVE. The purpose of this article is to suggest clinical indications for MRI in patients with breast cancer who have new uptake lesions in the femoral head on follow-up bone scans, by evaluating the incidence and causes of new uptake lesions. MATERIALS AND METHODS. Between January 2002 and July 2013, a total of 145 patients with breast cancer who showed new uptake in the femoral head on follow-up bone scans were included in our study. They were classified into two groups: group 1 consisted of 125 patients without known bone metastases, and group 2 consisted of 20 patients who already had bone metastases other than that in the femoral head. The Fisher exact test was performed for the statistical analysis. Thereafter, we reviewed MR images for characterization of the new abnormal uptake in the femoral head. RESULTS. New uptake lesions in the femoral head were metastatic in only 4.8% (6/125) of group 1 patients but in 75% (15/20) of group 2 patients (p < 0.0001). In both groups, no patient with a single uptake lesion in the femoral head had bone metastasis, whereas all patients with more than five new uptake lesions, including those of the femoral head, showed bone metastasis. Most MRI diagnoses for new uptake in the femoral head were fibrocystic change (15/30, 50%) and subchondral fracture (11/30, 36.7%). CONCLUSION. Most of the new uptake lesions in the femoral head detected on the follow-up bone scans in patients with breast cancer were benign. However, MRI could be considered in patients with known bone metastasis or with multiple new uptake lesions on bone scans.

  3. Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bone

    SciTech Connect

    Conklin, J.J.; Alderson, P.O.; Zizic, T.M.; Hungerford, D.S.; Densereaux, J.Y.; Gober, A.; Wagner, H.N.

    1983-04-01

    A prospective study of bone scanning for detection of ischemic necrosis of bone (INB) was performed in 36 patients (97% female, age range 16-36 yrs.) with systemic lupus erythematosis (SLE). Since the hips, knees, and shoulders are usually affected by INB in patients with SLE, 300 K converging collimator images of these joints were obtained on film and in digital format 2 to 3 hours after the injection of 20 mCi (740 MBq) of Tc-99m methylene diphosphonate. All patients underwent radiography of the joints, and 10 had intraosseous pressure determinations in the marrow space of affected joints (n . 31) for independent assessment of INB. Scans showed abnormally increased joint activity in 28 of the 36 patients. A total of 97 joints showed abnormalities, 19% in the hips, 34% in the knees, and 47% in the shoulders. Twenty-four of 27 joints with elevated bone marrow pressure (BMP) had abnormal scans (sensitivity . 89%), and scans were abnormal in 2 of 4 joints with normal pressures (specificity . 50%). The positive predictive value of the scans compared with BMP measurements was 92% (24/26). Eleven of 27 joints with abnormal BMP had abnormal radiographs, a sensitivity of 41%.

  4. Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bone

    SciTech Connect

    Conklin, J.J.; Alderson, P.O.; Zizic, T.M.; Hungerford, D.S.; Densereaux, J.Y.; Gober, A.; Wagner, H.N.

    1983-04-01

    A prospective study of bone scanning for detection of ischemic necrosis of bone (INB) was performed in 36 patients (97% female, age range 16-36 yrs.) with systemic lupus erythematosis (SLE). Since the hips, knees, and shoulders are usually affected by INB in patients with SLE, 300 K converging collimator images of these joints were obtained on film and in digital format 2 to 3 hours after the injection of 20 mCi (740 MBq) of Tc-99m methylene diphosphonate. All patients underwent radiography of the joints, and 10 had intraosseous pressure determinations in the marrow space of affected joints (n=31) for independent assessment of INB. Scans showed abnormally increased joint activity in 28 of the 36 patients. A total of 97 joints showed abnormalities, 19% in the hips, 34% in the knees, and 47% in the shoulders. Twenty-four of 27 joints with elevated bone marrow pressure (BMP) had abnormal scans (sensitivity = 89%), and scans were abnormal in 2 of 4 joints with normal pressures (specificity = 50%). The positive predicitive value of the scans compared with BMP measurements was 92% (24/26). Eleven of 27 joints with abnormal BMP had abnormal radiographs, a sensitivity of 41%.

  5. Bone and gallium scanning in the pre-op evaluation of the infected dysvascular foot

    SciTech Connect

    Stewart, C.; Sakimura, I.; Dillon, A.; Siegel, M.E.

    1984-01-01

    The purpose of this study is to determine the value of bone and gallium scans in predicting healing levels in the dysvascular foot with an infection requiring amputation. Healing requires amputation at a level both free of infection and with adequate blood flow. Forty-one such patients had bone and gallium scans and Doppler studies prior to amputation at a level selected by the surgeon. Eight patients required multiple surgeries before healing was obtained. Bone and soft tissue infections were determined from scans and healing levels predicted (SPHL) as the most distal amputation level free from infection: toectomy, Reye's, transmetatarsal, calcanectomy, Syme's, below knee. Doppler healing levels (DPHL) were predicted using a standard ischemic index. Doppler alone predicted the final healing level (FHL) in 41% with 59% needing more proximal amputation. Scans alone predicted FHL in 64% with 26% needing more proximal amputation. Ten percent were distal to the SPHL and all healed. These scans showed infection at transition sites between amputation levels, and the more proximal level had been predicted. Using the more proximal of the DPHL and SPHL the FHL was predicted in 78% with another 12% having more proximal amputation for nursing reasons. In 10% amputation was performed between DPHL and SPHL or at the more distal level. In no case was successful surgery performed distal to the more distal SPHL or DPHL. Bone and gallium scans used with Doppler studies are useful in optimizing the choice of amputation level in the infected, dysvascular foot.

  6. Osteoid osteoma - the role of bone scans in diagnosis and surgery

    SciTech Connect

    Matiets, M.

    1986-09-01

    Osteoid osteoma is a benign bone tumor which is most often seen in young males. Several imaging techniques have been used for the detection of osteoid osteoma lesions. Conventional x-ray was found to detect only two-thirds of lesions. Computerized tomography has been used to determine the extent of the osteoid osteoma's progress, particularly the soft tissue involvement. In this study, the radionuclide three-phase bone scan was positive in all six patients with surgically proven osteoid osteoma. In addition, nuclear medicine scans of bone specimens may be used to predict whether all of the tumor has been removed. Incomplete excision will likely result in recurrence. Since /sup 99m/Tc-MDP (methylene diphosphonate) is blood borne, it reflects blood flow to the tumor site. It also adsorbs onto the hydroxyapatite crystal. Its concentration is proportional to osteoblastic activity. A study was undertaken to evaluate the use of the three-phase bone scan in patient's referred with possible osteoid osteoma. In addition, scans of bone samples were used during the surgical procedures to evaluate complete tumor renewal.

  7. Incidental detection of superior sternal cleft on Technetium-99m methylene diphosphonate bone scan

    PubMed Central

    Aland, Nusrat IJ; Pawar, Shwetal Uday; Tilve, Gundu Hari

    2013-01-01

    A sternal cleft is an extremely rare developmental anomaly, which results from failure of fusion of sternal bars which contribute to the formation of the sternum. Most cases are diagnosed in early childhood, where it is associated with serious other midline defects. A sternal cleft is seen as a photopenic area on technetium-99m methylene diphosphonate bone scan and can be confused with other conditions. We report an extremely rare case of isolated upper sternal cleft in a 45-years-old male, found incidentally on Tc-99m MDP bone scan. PMID:24163521

  8. Role of bone scan in the assessment of polymyositis/dermatomyositis.

    PubMed

    An, Young-Sil; Suh, Chang-Hee; Jung, Ju-Yang; Kim, Hyoun-Ah

    2015-04-01

    The aim of this study was to determine the significance of bone scan findings in Korean polymyositis/dermatomyositis (PM/DM) patients. The participants in this study were 26 PM/DM patients who fulfilled the proposed criteria for definite or probable PM/DM. All patients had been examined by bone scan. The results were analyzed visually and quantitatively using the uptake ratios. Correlations between the bone scan parameters of six proximal muscle groups (trapezius, deltoid, biceps, iliopsoas, quadriceps, and gluteus medius and maximus) and clinical parameters (laboratory values and manual muscle test) representing disease activities were assessed. Based on visual analyses of their bone scans, 10 of 14 (71.4 %) patients with active PM/DM had abnormal muscle uptake. Visual grading of the bone scans had a sensitivity and specificity of 74 and 90.9 %, respectively, for the assessment of muscle inflammation. Maximal proximal muscle uptake ratios, as determined on the bone scans, were significantly higher in patients with active PM/DM than in those with inactive disease (median 1.97 vs. 1.02, p = 0.046). Maximal proximal uptake ratios correlated significantly with creatine kinase (r = 0.394, p = 0.046), lactate dehydrogenase (LDH, r = 0.473, p = 0.015), aldolase (r = 0.428, p = 0.029), erythrocyte sedimentation rate (r = 0.412, p = 0.036), C-reactive protein (r = 0.454, p = 0.002), and manual muscle test results (r = -0.399, p = 0.044). Mean proximal muscle uptake ratios correlated significantly with LDH (r = 0.438, p = 0.025) and aldolase (r = 0.572, p = 0.002). Visually assessed proximal muscle uptake grades and maximal proximal muscle uptake ratios as determined by bone scan correlated significantly with the levels of known PM/DM disease activity markers. The findings of this study suggest that bone scan is a useful imaging technique for the evaluation of PM/DM patients.

  9. Correlative Light and Scanning X-Ray Scattering Microscopy of Healthy and Pathologic Human Bone Sections

    PubMed Central

    Giannini, C.; Siliqi, D.; Bunk, O.; Beraudi, A.; Ladisa, M.; Altamura, D.; Stea, S.; Baruffaldi, F.

    2012-01-01

    Scanning small and wide angle X-ray scattering (scanning SWAXS) experiments were performed on healthy and pathologic human bone sections. Via crystallographic tools the data were transformed into quantitative images and as such compared with circularly polarized light (CPL) microscopy images. SWAXS and CPL images allowed extracting information of the mineral nanocrystalline phase embedded, with and without preferred orientation, in the collagen fibrils, mapping local changes at sub-osteon resolution. This favorable combination has been applied for the first time to biopsies of dwarfism syndrome and Paget's disease to shed light onto the cortical structure of natural bone in healthy and pathologic sections. PMID:22666538

  10. The Effect of Changing Scan Mode on Trabecular Bone Score Using Lunar Prodigy.

    PubMed

    Chen, Weiwen; Slattery, Anthony; Center, Jacqueline; Pocock, Nicholas

    2016-10-01

    Trabecular bone score (TBS) is a measure of gray scale homogeneity that correlates with trabecular microarchitecture and is an independent predictor of fracture risk. TBS is being increasingly used in the assessment of patients at risk of osteoporosis and has recently been incorporated into FRAX(®). GE Lunar machines acquire spine scans using 1 of 3 acquisition modes depending on abdominal tissue thickness (thin, standard, and thick). From a database review, 30 patients (mean body mass index: 30.8, range 26.2-34.1) were identified who had undergone lumbar spine DXA scans (GE Lunar Prodigy, software 14.10; Lunar Radiation Corporation, Madison, WI) in both standard mode and thick mode, on the same day with no repositioning. Lumbar spine bone mineral density (L1-L4) and TBS were derived from the 30 paired spine scans. There was no significant difference in lumbar spine bone mineral density between the 2 scanning modes. There were, however, significant higher TBS values from the spine scans acquired in thick mode compared to the TBS values derived from spine acquisitions in standard mode (mean TBS difference: 0.24 [20%], standard deviation ±0.10). In conclusion, these preliminary data suggest that TBS values acquired in the GE Lunar Prodigy are dependent on the scanning mode used. Further evaluation is required to confirm the cause and develop appropriate protocols.

  11. Study of fossil bones by synchrotron radiation micro-spectroscopic techniques and scanning electron microscopy.

    PubMed

    Zougrou, I M; Katsikini, M; Pinakidou, F; Paloura, E C; Papadopoulou, L; Tsoukala, E

    2014-01-01

    Earlymost Villafranchian fossil bones of an artiodactyl and a perissodactyl from the Milia excavation site in Grevena, Greece, were studied in order to evaluate diagenetic effects. Optical microscopy revealed the different bone types (fibro-lamellar and Haversian, respectively) of the two fragments and their good preservation state. The spatial distribution of bone apatite and soil-originating elements was studied using micro-X-ray fluorescence (µ-XRF) mapping and scanning electron microscopy. The approximate value of the Ca/P ratio was 2.2, as determined from scanning electron microscopy measurements. Bacterial boring was detected close to the periosteal region and Fe bearing oxides were found to fill bone cavities, e.g. Haversian canals and osteocyte lacunae. In the perissodactyl bone considerable amounts of Mn were detected close to cracks (the Mn/Fe weight ratio takes values up to 3.5). Goethite and pyrite were detected in both samples by means of metallographic microscopy. The local Ca/P ratio determined with µ-XRF varied significantly in metal-poor spots indicating spatial inhomogeneities in the ionic substitutions. XRF line scans that span the bone cross sections revealed that Fe and Mn contaminate the bones from both the periosteum and medullar cavity and aggregate around local maxima. The formation of goethite, irrespective of the local Fe concentration, was verified by the Fe K-edge X-ray absorption fine structure (XAFS) spectra. Finally, Sr K-edge extended XAFS (EXAFS) revealed that Sr substitutes for Ca in bone apatite without obvious preference to the Ca1 or Ca2 unit-cell site occupation.

  12. [Importance of bone scanning and osteoscintimetry for assessing development of acute haematogenic childhood osteomyelitis (author's transl)].

    PubMed

    Fotter, R; Höllwarth, M

    1980-01-01

    Bone scanning with 99m-Tc-MDP is generally used for the early diagnosis of acute haematogenic childhood osteomyelitis. The combination of this method with radionuclide osteoscintimetry and the evaluation of the relative uptake ratio supply objective criteria for assessing the development of the disease. They permit statements as to the morphological and functional aspects of the disease and thus facilitate clinical assessment.

  13. Effect of iron on the biodistribution of bone scanning agents in humans

    SciTech Connect

    Choy, D.; Murray, I.P.C.; Hoschl, R.

    1981-07-01

    Nine patients with chronic iron overload, resulting from either repeated transfusions or hemochromatosis, had bone scans that were characterized by a reduction of bony uptake, marked increase in renal activity, and a significant increase in soft-tissue accumulation of /sup 99m/Tc-labeled bone-seeking agents. These findings were supported by semiquantitative computer analysis. The probable mechanisms of altered biodistribution and the possible role of serum ferritin are discussed. The importance of realizing the effect of excess iron on skeletal scintigraphy is further emphasized by the results of bone scanning in another patient in whom acute iron overload following infusion of iron-dextran resulted in excessive blood pool labeling.

  14. Scoring systems of quantitative bone scanning in prostate cancer: historical overview, current status and future perspectives.

    PubMed

    Zafeirakis, Athanasios

    2014-01-01

    Whole-body bone scintigraphy using technetium-99m-methylene-diphosphonate ((99m)Tc-MDP) is the most widely used radionuclide imaging modality applied in patients with prostate cancer. With this technique, the choice of methods to estimate the extend of the metastatic disease on the skeletal system includes various different approaches, classified in two main categories: First, the quantitative measurements of tracer uptake, defined either as the percentage of the injected dose of tracer, or as the more complicated plasma clearance techniques and second, the various semi-quantitative scoring systems of the bone scan images. These scoring systems can be based either on visual counting of bone lesions, or on the estimation of a numerical index that expresses the fractional involvement of each bone by tumour, called "Bone Scan Index" (BSI); the latter can be produced either visually (manually) or by the more sophisticated techniques of fully- or semi-automated (computerized) forms. In this review, a brief chronological overview of the aforementioned methods is presented, along with the main advantages, drawbacks and the prognostic implications of each method. There remains, however, the challenge of defining, developing and validating the optimal measurement methodology in order these scoring systems to obtain a wider clinical use.

  15. CD87-positive tumor cells in bone marrow aspirates identified by confocal laser scanning fluorescence microscopy.

    PubMed

    Noack, F; Helmecke, D; Rosenberg, R; Thorban, S; Nekarda, H; Fink, U; Lewald, J; Stich, M; Schutze, K; Harbeck, N; Magdolen, V; Graeff, H; Schmitt, M

    1999-10-01

    Dissemination of single tumor cells to the bone marrow is a common event in cancer. The clinical significance of cytokeratin-positive cells detected in the bone marrow of cancer patients is still a matter of debate. In gastric cancer, overexpression of the receptor (uPAR or CD87) for the serine protease urokinase-type plasminogen activator (uPA) in disseminated cancer cells indicates shorter survival of cancer patients. A new immunofluorescence approach, applying confocal laser scanning microscopy, is introduced to locate CD87 antigen in cytokeratin-positive tumor cells and to quantify the CD87 antigen by consecutive scanning. At first, cytokeratin 8/18/19-positive carcinoma cells are identified at excitation wavelength 488 nm using monoclonal antibody A45B/B3 to the cytokeratins and goat anti-mouse IgG labeled with the fluorochrome Alexa488. Next, CD87 in tumor cells is identified by chicken antibody HU277 to the uPA-receptor and goat anti-chicken IgY labeled with fluorochrome Alexa568 (excitation wavelength 568 nm) and the fluorescence signal quantified on a single cell basis using fluorescently labeled latex beads as the fluorescence reference. From 16 patients with gastric or esophageal carcinoma, bone marrow aspirates were obtained, stained for cytokeratins and CD87 and then subjected to laser scanning fluorescence microscopy. Three of six gastric cancer patients had tumor cells present in the bone marrow of which 2 stained for CD87. Three of ten esophageal carcinoma patients had tumor cells in the bone marrow, all three samples stained for CD87. CD87-positive tumor cells were also dissected from stained bone marrow aspirates by laser microdissection microscope to allow analysis of single cells at the gene level.

  16. The utilization of Gleason grade as the primary criterion for ordering nuclear bone scan in newly diagnosed prostate cancer patients.

    PubMed

    Ritenour, Chad W M; Abbott, John T; Goodman, Michael; Alazraki, Naomi; Marshall, Fray F; Issa, Muta M

    2009-10-02

    Utilization of nuclear bone scans for staging newly diagnosed prostate cancer has decreased dramatically due to PSA-driven stage migration. The current criteria for performing bone scans are based on limited historical data. This study evaluates serum PSA and Gleason grade in predicting positive scans in a contemporary large series of newly diagnosed prostate cancer patients. Eight hundred consecutive cases of newly diagnosed prostate cancer over a 64-month period underwent a staging nuclear scan. All subjects had histologically confirmed cancer. The relationship between PSA, Gleason grade, and bone scan was examined by calculating series of crude, stratified, and adjusted odds ratios with corresponding 95% confidence intervals. Four percent (32/800) of all bone scans were positive. This proportion was significantly lower in patients with Gleason score or=8 (18.8%, p < 0.001). Among patients with Gleason score bones scans was 70-fold higher when the PSA was >30 ng/ml compared to or=8, the rate was significantly higher (27.9 vs. 0%) when PSA was >10 ng/ml compared to bone scans in newly diagnosed prostate cancer patients. The PSA threshold for ordering bone scans should be adjusted according to Gleason score. For patients with Gleason scores bone scan if the PSA is >30 ng/ml. However, for patients with a high Gleason score (8-10), we recommend a bone scan if the PSA is >10 ng/ml.

  17. Paraneoplastic syndrome demonstrated on (99m)Tc-HMDP bone scan.

    PubMed

    Lancelot, Sophie; Giammarile, Francesco; Tescaru, Agnes

    2016-11-01

    A 23-year-old man, with no relevant medical history, presented with inflammatory peripheral and axial polyarthritis, wrist pain, and persistent low-grade fever for the past 4 months. A bone scintigraphy showed intense periosteal early and delayed uptake in long bones, with normal uptake in the spine, pelvis, and rib cage, and no clear focus of hypermetabolism. CT scan revealed a mediastinal mass. A biopsy of the mass demonstrated Hodgkin lymphoma with bulky disease. This paraneoplastic syndrome as the first sign of intrathoracic Hodgkin's disease is rare.

  18. The technetium phosphate bone scan in the diagnosis of osteomyelitis in childhood

    SciTech Connect

    Howie, D.W.; Savage, J.P.; Wilson, T.G.; Paterson, D.

    1983-04-01

    We reviewed the technetium phosphate scans of 280 patients who had been referred with a clinical diagnosis of osteomyelitis in order to establish the diagnostic accuracy of this procedure. Strict criteria were established to define two subgroups: one of patients with proved osteomyelitis and one of patients who definitely did not have osteomyelitis. The scan correctly identified osteomyelitis at fifty-five of sixty-two sites, and was correctly negative in seventy-four of seventy-nine patients without osteomyelitis. The scan correctly distinguished all cases of cellulitis or soft-tissue abscess from osteomyelitis, but identified osteomyelitis in eight of thirty-nine patients with septic arthritis. The phosphate bone scan maintained this accuracy through any duration of symptoms, and performed almost equally well at all skeletal sites and in all age groups.

  19. Scanning and transmission electron microscopy for evaluation of order/disorder in bone structure.

    PubMed

    Suvorova, Elena I; Petrenko, Pavel P; Buffat, Philippe A

    2007-01-01

    A comparative characterization of the structure of normal and abnormal (osteoporotic) human lumbar and thoracic vertebrae samples was carried out to reveal the type of possible disorder. Samples from the bone fragments extracted during the surgery due to vertebra fractures were examined by scanning electron microscopy (SEM), conventional and high resolution transmission electron microscopy (TEM and HRTEM), and X-ray energy dispersive spectroscopy (EDS). Contrary to what might be expected in accordance with possible processes of dissolution, formation and remineralization of hard tissues, no changes in phase composition of mineral part, crystal sizes (length, width, and thickness), and arrangement of crystals on collagen fibers were detected in abnormal bones compared to the normal ones. The following sizes were determined by HRTEM for all bone samples: bones. EDS showed that this organic tissue was not mineralized. Penetration of such organic fibers inside bones can result in bone dilatation and lower the mineral density, deteriorating the mechanical properties and finally terminating in fracture.

  20. Bone scan

    MedlinePlus

    ... the test will last about 1 hour. The scanner's camera may move above and around you. You may need to change positions. You will probably be asked to drink extra water after you receive the radiotracer to keep the material from collecting in your bladder.

  1. Asymmetric (99m)Tc-MDP uptake in mineralized tendons might mimic bone lesions: heterotopic tendon mineralization on a (99m)Tc-MDP bone scan and a (18)F-FDG PET/CT scan.

    PubMed

    Chen, Yu-Ren; Hsieh, Te-Chun; Yen, Kuo-Yang; Shen, Yeh-You; Kao, Chia-Hung

    2014-05-01

    A 55-year-old man was a hepatocellular carcinoma patient, diagnosed by sonography and a biopsy. Because of his musculoskeletal tenderness, a bone scan was performed to exclude skeletal metastasis. A subsequent F-FDG PET/CT scan revealed that the unilateral abnormal uptake seen on the bone scan was actually a mineralized tendon. A mineralized tendon is easily detectable using Tc-MDP; therefore, it is imperative to differentiate between bone lesions and mineralized tendons. In addition, few studies have reported F-FDG uptake in a calcified tendon.

  2. Characterizing the composition of bone formed during fracture healing using scanning electron microscopy techniques.

    PubMed

    Perdikouri, Christina; Tägil, Magnus; Isaksson, Hanna

    2015-01-01

    About 5-10% of all bone fractures suffer from delayed healing, which may lead to non-union. Bone morphogenetic proteins (BMPs) can be used to induce differentiation of osteoblasts and enhance the formation of the bony callus, and bisphosphonates help to retain the newly formed callus. The aim of this study was to investigate if scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) can identify differences in the mineral composition of the newly formed bone compared to cortical bone from a non-fractured control. Moreover, we investigate whether the use of BMPs and bisphosphonates-alone or combined-may have an effect on bone mineralization and composition. Twelve male Sprague-Dawley rats at 9 weeks of age were randomly divided into four groups and treated with (A) saline, (B) BMP-7, (C) bisphosphonates (Zoledronate), and (D) BMP-7 + Zoledronate. The rats were sacrificed after 6 weeks. All samples were imaged using SEM and chemically analyzed with EDS to quantify the amount of C, N, Ca, P, O, Na, and Mg. The Ca/P ratio was the primary outcome. In the fractured samples, two areas of interest were chosen for chemical analysis with EDS: the callus and the cortical bone. In the non-fractured samples, only the cortex was analyzed. Our results showed that the element composition varied to a small extent between the callus and the cortical bone in the fractured bones. However, the Ca/P ratio did not differ significantly, suggesting that the mineralization at all sites is similar 6 weeks post-fracture in this rat model.

  3. Technetium-99m-alendronate: a new radiopharmaceutical for bone scanning.

    PubMed

    Arteaga de Murphy, C; Meléndez-Alafort, L; Montoya-Molina, C; Sepúlveda-Méndez, J

    1996-01-01

    The purpose of this paper is to report the preparation of a new technetium-99m-radiopharmaceutical for bone scanning. The chelating agent for 99mTc is a new bisphosphonate, alendronate, 4-amino-1-hydroxy-butylidene-1, 1-bisphosphonate (ABP) used as a treatment for osteoporosis. ABP, because of its amino group, seems to be better suited to form a strong and stable complex with technetium-99m and therefore might be better than 99mTc-etidronate (HEDP) or 99mTc-medronate (MDP) for bone scanning. A sterile dry kit containing APB, a reducing agent and a stabilizer was prepared. The parameters studied were molar concentrations, pH, shelf life, labeling efficiency and radiochemical purity. The oven dried sterile kit was formulated with 5 mg ABP, 0.25 mg stannous fluoride and 0.025 mg gentisic acid at pH 2.5-3.5. The labeling efficiency with 20-1500 MBq of pertechnetate (99mTcO4-) was over 95% at room temperature and was stable for 5 h. Technetium-99m-alendronate was tested in two rabbits and it proved to be a promising new radiopharmaceutical for bone scanning. Work is underway to study 99mTc-ABP biodistribution in a statistically significant number of laboratory animals and, later on, to determine radiopharmacokinetic parameters in normal volunteers.

  4. Bone scan findings in Kienböck's disease. A case report with atypical findings and literature review.

    PubMed

    Stuckey, S L; Kalff, V; Hoy, G

    1997-07-01

    The authors present an 18-year-old man who had a 5-month history of a painful left wrist. Despite the prolonged history, discrete photopenia on the blood-pool phase and photopenia relative to the remainder of the ipsilateral carpus on the delayed phase of a bone scan in the region of the lunate was shown. When Kienböck's disease is seen in its late phase, the bone scan findings may be atypical in that they may not show the usual three-phase bone scintigraphic evidence of bone remodeling expected in delayed diagnosis avascular necrosis. A review of the previous literature is presented.

  5. Bone Scan Index: A Quantitative Treatment Response Biomarker for Castration-Resistant Metastatic Prostate Cancer

    PubMed Central

    Dennis, Elizabeth R.; Jia, Xiaoyu; Mezheritskiy, Irina S.; Stephenson, Ryan D.; Schoder, Heiko; Fox, Josef J.; Heller, Glenn; Scher, Howard I.; Larson, Steven M.; Morris, Michael J.

    2012-01-01

    Purpose There is currently no imaging biomarker for metastatic prostate cancer. The bone scan index (BSI) is a promising candidate, being a reproducible, quantitative expression of tumor burden seen on bone scintigraphy. Prior studies have shown the prognostic value of a baseline BSI. This study tested whether treatment-related changes in BSI are prognostic for survival and compared BSI to prostate-specific antigen (PSA) as an outcome measure. Patients and Methods We retrospectively examined serial bone scans from patients with castration-resistant metastatic prostate cancer (CRMPC) enrolled in four clinical trials. We calculated BSI at baseline and at 3 and 6 months on treatment and performed univariate and bivariate analyses of PSA, BSI, and survival. Results Eighty-eight patients were scanned, 81 of whom have died. In the univariate analysis, the log percent change in BSI from baseline to 3 and 6 months on treatment prognosticated for survival (hazard ratio [HR], 2.44; P = .0089 and HR, 2.54; P < .001, respectively). A doubling in BSI resulted in a 1.9-fold increase in risk of death. Log percent change in PSA at 6 months on treatment was also associated with survival (HR, 1.298; P = .013). In the bivariate analysis, change in BSI while adjusting for PSA was prognostic at 3 and 6 months on treatment (HR, 2.368; P = .012 and HR, 2.226; P = .002, respectively), but while adjusting for BSI, PSA was not prognostic. Conclusion These data furnish early evidence that on-treatment changes in BSI are a response indicator and support further exploration of bone scintigraphy as an imaging biomarker in CRMPC. PMID:22231045

  6. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    NASA Astrophysics Data System (ADS)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  7. Camurati-Engelmann disease in a family from Croatian Island: an old bone scan confirmed pattern of inheritance.

    PubMed

    Baretić, Maja; Korsić, Mirko; Potocki, Kristina; Horvatić, Gordana Herceg; Orlić, Zeljka Crncević

    2014-06-01

    34-year old patient had history of muscular wasting, easy fatigability, pain in extremities and waddling gait since age of four. During the time, neuromuscular disease was suspected, but not confirmed. Elevated bone alkaline phosphatase as well as other bone turnover markers (osteocalcin, procollagen, telopeptide) indicated further skeletal evaluation. Symmetrical enhanced uptake on technetium methylene diphosphonate [99mTc]MPD bone scintigraphy at diaphyses of longitudinal bones and scull matched cortical thickening of long bones and sclerosis of the scull seen at radiograms. Those findings pointed to Camurati-Engelmann disease misdiagnosed for the long time. This rare genetic autosomal dominant disorder was retrospectively diagnosed in asymptomatic father too on the basis of bone scans done long time ago. Old family member scans confirmed heredity pattern of the disease.

  8. Microwave bone imaging: a preliminary scanning system for proof-of-concept

    PubMed Central

    Cuccaro, Antonio; Solimene, Raffaele; Brancaccio, Adriana; Basile, Bruno; Ammann, Max J.

    2016-01-01

    This Letter introduces a feasibility study of a scanning system for applications in biomedical bone imaging operating in the microwave range 0.5–4 GHz. Mechanical uncertainties and data acquisition time are minimised by using a fully automated scanner that controls two antipodal Vivaldi antennas. Accurate antenna positioning and synchronisation with data acquisition enables a rigorous proof-of-concept for the microwave imaging procedure of a multi-layer phantom including skin, fat, muscle and bone tissues. The presence of a suitable coupling medium enables antenna miniaturisation and mitigates the impedance mismatch between antennas and phantom. The three-dimensional image of tibia and fibula is successfully reconstructed by scanning the multi-layer phantom due to the distinctive dielectric contrast between target and surrounding tissues. These results show the viability of a microwave bone imaging technology which is low cost, portable, non-ionising, and does not require specially trained personnel. In fact, as no a-priori characterisation of the antenna is required, the image formation procedure is very conveniently simplified. PMID:27733930

  9. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    NASA Astrophysics Data System (ADS)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  10. Incidental detection of gastrointestinal stromal tumor by Tc-99m MDP bone scan.

    PubMed

    Shepherd, Timothy M; Idakoji, Ibrahim A; Pampaloni, Miguel H

    2012-02-01

    This case demonstrates extraosseous 99m-technetium methylene diphosphonate (Tc-99m MDP) accumulation from a gastrointestinal stromal tumor. A 75-year-old woman underwent a temporal bone CT for conductive hearing loss that showed sclerosis in the right occipital condyle. Follow-up Tc-99m MDP bone scan for osseous metastases instead showed a mass-like extraosseous accumulation of Tc-99m MDP in the anterior left upper quadrant. Differential diagnoses included gastric cancer, lymphoma, metastatic melanoma, systemic hypercalcemia, or heterotopic mesenteric ossification. Contrast CT showed a well-circumscribed mass arising from the stomach, and subsequent pathology confirmed gastrointestinal stromal tumor. These tumors rarely can contain osteoclast-like giant cells and should be considered for extraosseous Tc-99m MDP accumulation.

  11. SCAN+

    SciTech Connect

    Kenneth Krebs, John Svoboda

    2009-11-01

    SCAN+ is a software application specifically designed to control the positioning of a gamma spectrometer by a two dimensional translation system above spent fuel bundles located in a sealed spent fuel cask. The gamma spectrometer collects gamma spectrum information for the purpose of spent fuel cask fuel loading verification. SCAN+ performs manual and automatic gamma spectrometer positioning functions as-well-as exercising control of the gamma spectrometer data acquisitioning functions. Cask configuration files are used to determine the positions of spent fuel bundles. Cask scanning files are used to determine the desired scan paths for scanning a spent fuel cask allowing for automatic unattended cask scanning that may take several hours.

  12. Diffuse liver uptake on (99m)Tc-MDP bone scan secondary to severe hepatic failure.

    PubMed

    Chen, Paul; Marentis, Theodore; Brown, Richard K J

    2014-07-01

    Hepatic uptake on an MDP bone scan is a non-specific finding. When present, the etiology needs to be determined. The differential diagnosis depends on the pattern of uptake. Metastatic breast and colon cancer are frequent causes of focal faint uptake. Diffuse uptake is rare, but can be seen with hepatitis, amyloid, and IV gadolinium administration. In addition, aluminum breakthrough from the molybdenum generator can cause colloid formation and subsequent diffuse hepatic uptake. We present a case of diffuse uptake in a patient with acute hepatic failure. The etiology of the failure was extensive thrombosis of the inferior vena cava (IVC).

  13. Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

    SciTech Connect

    Straten, Marcel van; Schaap, Michiel; Dijkshoorn, Marcel L.; Greuter, Marcel J.; Lugt, Aad van der; Krestin, Gabriel P.; Niessen, Wiro J.

    2011-11-15

    Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration

  14. Noninvasive Ultrasound Imaging for Bone Quality Assessment Using Scanning Confocal Acoustic Diagnosis, μCT, DXA Measurements, and Mechanical Testing

    NASA Astrophysics Data System (ADS)

    Qin, Yi-Xian; Xia, Yi; Lin, Wei; Mittra, Erik; Rubin, Clint; Gruber, Barry

    Osteoporosis is a disease characterized by decreased bone mass and progressive deterioration of the microstructure, affecting both mineral density and bone's fragility. Current diagnoses are only measuring apparent bone mineral density (AppBMD). Using our newly developed scanning confocal acoustic diagnostic (SCAD) system, we evaluated the ability of quantitative ultrasound in noninvasively predicting bone's quantity and quality on 19 human cadaver calcanei. Results show that ultrasound attenuation image on intact calcaneus represents bone mass distribution. High correlation (R=0.82) exists between SCAD determined broadband ultrasound attenuation (BUA) and DXA determined AppBMD at the calcaneus, as well as in the AppBMD result at femoral neck (R=0.81). SCAD determined BUA and ultrasound velocity (UV) are highly correlated with the micro-CT and mechanical testing determined bone quantity and quality parameters. These results suggest that image-based quantitative ultrasound is able to identify ROI and predict both bone mass and strength.

  15. Numerical investigation of ultrasonic attenuation through 2D trabecular bone structures reconstructed from CT scans and random realizations.

    PubMed

    Gilbert, Robert P; Guyenne, Philippe; Li, Jing

    2014-02-01

    In this paper, we compare ultrasound interrogations of actual CT-scanned images of trabecular bone with artificial randomly constructed bone. Even though it is known that actual bone does not have randomly distributed trabeculae, we find that the ultrasound attenuations are close enough to cast doubt on any microstructural information, such as trabeculae width and distance between trabeculae, being gleaned from such experiments. More precisely, we perform numerical simulations of ultrasound interrogation on cancellous bone to investigate the phenomenon of ultrasound attenuation as a function of excitation frequency and bone porosity. The theoretical model is based on acoustic propagation equations for a composite fluid-solid material and is solved by a staggered-grid finite-difference scheme in the time domain. Numerical experiments are performed on two-dimensional bone samples reconstructed from CT-scanned images of real human calcaneus and from random distributions of fluid-solid particles generated via the turning bands method. A detailed comparison is performed on various parameters such as the attenuation rate and speed of sound through the bone samples as well as the normalized broadband ultrasound attenuation coefficient. Comparing results from these two types of bone samples allows us to assess the role of bone microstructure in ultrasound attenuation. It is found that the random model provides suitable bone samples for ultrasound interrogation in the transverse direction of the trabecular network.

  16. Association between number and sites of new bone scan abnormalities and presence of skeletal metastases in patients with breast cancer

    SciTech Connect

    Jacobson, A.F.; Stomper, P.C.; Jochelson, M.S.; Ascoli, D.M.; Henderson, I.C.; Kaplan, W.D. )

    1990-04-01

    Review of 1,441 bone scans performed on 242 breast cancer patients without known skeletal metastases identified 239 scans with new abnormalities. Findings on 54 of these 239 scans (23%) represented bone metastases. The proportion of scans reflecting metastases, grouped by the number of new abnormalities, was: (1) 20/182 (11%); (2) 9/26 (35%); (3) 4/9 (45%); (4) 1/2 (50%); greater than or equal to 5-20/20 (100%). When metastatic disease presented as a bone scan with 1-4 new abnormalities, the spine was the most common site of involvement (18 of 34 (53%)), followed by the skull (5/34; 15%), extremities and sternum (each 4/34; 12%). Rib lesions were the most common new findings on scans with less than 5 new abnormalities (seen on 76 of 219 scans (35%)) but only infrequently represented metastases (n = 2). Considering as indicative of malignancy only, those bone scans which demonstrated either (a) greater than or equal to 5 new abnormalities, (b) initial radiographic correlation suggestive of metastases, or (c) thoracic spine lesions with normal correlative radiographs, the presence of skeletal metastatic disease could be predicted with a sensitivity of 0.80 and a specificity of 0.94.

  17. Development of a computer-aided diagnostic scheme for detection of interval changes in successive whole-body bone scans

    SciTech Connect

    Shiraishi, Junji; Li Qiang; Appelbaum, Daniel; Pu Yonglin; Doi, Kunio

    2007-01-15

    Bone scintigraphy is the most frequent examination among various diagnostic nuclear medicine procedures. It is a well-established imaging modality for the diagnosis of osseous metastasis and for monitoring osseous tumor response to chemotherapy and radiation therapy. Although the sensitivity of bone scan examinations for detection of bone abnormalities has been considered to be relatively high, it is time consuming to identify multiple lesions such as bone metastases of prostate and breast cancers. In addition, it is very difficult to detect subtle interval changes between two successive abnormal bone scans, because of variations in patient conditions, the accumulation of radioisotopes during each examination, and the image quality of gamma cameras. Therefore, we developed a new computer-aided diagnostic (CAD) scheme for the detection of interval changes in successive whole-body bone scans by use of a temporal subtraction image which was obtained with a nonlinear image-warping technique. We carried out 58 pairs of successive bone scans in which each scan included both posterior and anterior views. We determined 107 'gold-standard' interval changes among the 58 pairs based on the consensus of three radiologists. Our computerized scheme consisted of seven steps, i.e., initial image density normalization on each image, image matching for the paired images, temporal subtraction by use of the nonlinear image-warping technique, initial detection of interval changes by use of temporal-subtraction images, image feature extraction of candidates of interval changes, rule-based tests by use of 16 image features for removing some false positives, and display of the computer output for identified interval changes. One hundred seven gold standard interval changes included 71 hot lesions (uptake was increased compared with the previous scan, or there was new uptake in the current scan) and 36 cold lesions (uptake was decreased or disappeared) for anterior and posterior views. The

  18. Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning.

    PubMed

    Yan, Ya-Bo; Qi, Wei; Wang, Jun; Liu, Lin-Feng; Teo, Ee-Chon; Tianxia, Qiu; Ba, Jing-jing; Lei, Wei

    2011-07-01

    Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from centroid of μ-CT scanned human vertebral body, were analyzed to determine the architectural parameters (BV/TV, BS/BV, Tb.Th, Tb.N, Tb.Sp) of trabeculae within these volumes and to suggest an optimal volume for representative architectural parameters of the overall scanned volume. Nonlinear curve fitting method was also applied to obtain the correlation between the parameters and the volume of interests. The results show different volumes of interests give different morphological indices of BV/TV, BS/BV, Tb.N and Tb.Sp within a specific scanned vertebral body. Tb.Th shows relatively small variation (0.8%) even with sample volume of less than (2mm)(3). Statistical analysis shows that with sample volume of less than (6mm)(3), significant different in the measured BV/TV comparing against the control group. Tb.N and Tb.Sp show significant different values against the control group for volume of interest less than (4mm)(3) and (5mm)(3), respectively. However, no significant differences were observed in the indices of BS/BV and Tb.Th. Present study shows that an optimal volume of interests of greater than (6mm)(3) be selected to predict the architectural parameters of trabeculae of human vertebral bodies.

  19. Stochastic predictors from the DXA scans of human lumbar vertebrae are correlated with the microarchitecture parameters of trabecular bone.

    PubMed

    Dong, Xuanliang Neil; Pinninti, Rajeshwar; Tvinnereim, Amy; Lowe, Timothy; Di Paolo, David; Shirvaikar, Mukul

    2015-09-18

    The purpose of this study was to provide a novel stochastic assessment of inhomogeneous distribution of bone mineral density (BMD) from the Dual-energy X-ray Absorptiometry (DXA) scans of human lumbar vertebrae and identify the stochastic predictors that were correlated with the microarchitecture parameters of trabecular bone. Eighteen human lumbar vertebrae with intact posterior elements from 5 cadaveric spines were scanned in the posterior-anterior projection using a Hologic densitometer. The BMD map of human vertebrae was obtained from the raw data of DXA scans by directly operating on the transmission measurements of low- and high-energy X-ray beams. Stochastic predictors were calculated by fitting theoretical models onto the experimental variogram of the BMD map, rather than grayscale images, from DXA scans. In addition, microarchitecture parameters of trabecular bone were measured from the 3D images of human vertebrae acquired using a Micro-CT scanner. Significant correlations were observed between stochastic predictors and microarchitecture parameters. The sill variance, representing the standard deviation of the BMD map to some extent, had significantly positive correlations with bone volume, trabecular thickness, trabecular number and connectivity density. The sill variance was also negatively associated with bone surface to volume ratio and trabecular separation. This study demonstrates that the stochastic assessment of the inhomogeneous distribution of BMD from DXA scans of human lumbar vertebrae can reveal microarchitecture information of trabecular bone. However, future studies are needed to examine the potential of stochastic predictors from routine clinical DXA scans in providing bone fragility information complementary to BMD.

  20. Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

    NASA Technical Reports Server (NTRS)

    Whalen, Robert T.; Napel, Sandy; Yan, Chye H.

    1996-01-01

    Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

  1. Three-dimensional model of the skull and the cranial bones reconstructed from CT scans designed for rapid prototyping process.

    PubMed

    Skrzat, Janusz; Spulber, Alexandru; Walocha, Jerzy

    2016-01-01

    This paper presents the effects of building mesh models of the human skull and the cranial bones from a series of CT-scans. With the aid of computer so ware, 3D reconstructions of the whole skull and segmented cranial bones were performed and visualized by surface rendering techniques. The article briefly discusses clinical and educational applications of 3D cranial models created using stereolitographic reproduction.

  2. Metastatic mimics on bone scan: “All that glitters is not metastatic”

    PubMed Central

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    In this pictorial review, cases where benign diseases caused a diagnostic dilemma on bone scan are illustrated. This review highlights the value of correlative imaging- single-photon emission computed tomography/computed tomography (CT), CT, and magnetic resonance imaging in solving the diagnostic problem by exact localization and characterization of the lesions. All these eventually lead to increased diagnostic confidence, better and more accurate reporting and avoidance of delay in initiation of treatment due to equivocal results. The imaging features of these benign pathologies – which are “mimics of metastatic disease,” are elaborated so that the reader can incorporate them while reporting so as to avoid mis-interpretations. PMID:27385887

  3. Silver methenamine staining for scanning electron microscopy of bone sections containing biomaterials.

    PubMed

    Frayssinet, P; Hanker, J S; Rouquet, N; Primout, I; Giammara, B

    1999-01-01

    Sections of tissue containing orthopedic materials are currently used to study the compatibility of those materials and to perform electron probe microanalysis at the material-tissue interface. Identification of the cells in contact with the material by Scanning electron microscopy (SEM) is of interest. We have developed a method for staining cells and tissue structures embedded in polymethyl methacrylate with silver methenamine once the sections have been obtained. Sections were prepared by grinding, and the silver methenamine was applied after oxidation with periodic acid. The procedure was carried out in a microwave oven. Backscatter SEM showed staining of the cell nucleus membrane, chromatin, the nuclear organizers, and the chromosomes of dividing cells. The cytoplasm and the cytoplasmic membrane were also stained. Collagen fibers of the extracellular matrix and the mineralized matrix of bone were labeled. Material particles in the macrophages were easily recognizable and Energy-Dispersive Spectrometer were not impaired by the presence of silver in the preparation.

  4. Constructing a multi-scan synchrotron X-ray microscope to study the function of osteocyte canaliculi in mouse bone

    SciTech Connect

    Nango, Nobuhito; Kubota, Shogo; Yashiro, Wataru; Momose, Atsushi; Takada, Yasunari; Matsuo, Koichi

    2012-07-31

    Formulating a multi-scan method applied to an X-ray microscope CT with synchrotron radiation, we attempted to analyze the 3D functional structure of osteocyte canaliculi inside the cortical bone of a mouse tibia. We employed a two-method combination to scan the same position of the specimen. To extract the internal bone canalicular structure, we first combined a Talbot interferometer with an X-ray microscope, and applied a differential phase imaging method to measure the absolute value of bone mineral around the canaliculi. Next, we used the X-ray microscope without the Talbot interferometer under a defocus condition, moving the specimen toward the zone plate by 6 mm. This defocus contrast method visualizes the canaliculi by emphasizing the edges of the bone. We performed CT scans by the two configurations and precisely aligned resultant 3D images so that the same position in the specimen is compared. We could extract the osteocyte canaliculi and evaluate the mineral density of their surroundings. The degree of mineralization varied for each osteocyte lacuna and canaliculus. The multi-scan microscopic X-ray CT is a powerful tool for analyzing bone mineralization.

  5. Constructing a multi-scan synchrotron X-ray microscope to study the function of osteocyte canaliculi in mouse bone

    NASA Astrophysics Data System (ADS)

    Nango, Nobuhito; Kubota, Shogo; Yashiro, Wataru; Momose, Atsushi; Takada, Yasunari; Matsuo, Koichi

    2012-07-01

    Formulating a multi-scan method applied to an X-ray microscope CT with synchrotron radiation, we attempted to analyze the 3D functional structure of osteocyte canaliculi inside the cortical bone of a mouse tibia. We employed a two-method combination to scan the same position of the specimen. To extract the internal bone canalicular structure, we first combined a Talbot interferometer with an X-ray microscope, and applied a differential phase imaging method to measure the absolute value of bone mineral around the canaliculi. Next, we used the X-ray microscope without the Talbot interferometer under a defocus condition, moving the specimen toward the zone plate by 6 mm. This defocus contrast method visualizes the canaliculi by emphasizing the edges of the bone. We performed CT scans by the two configurations and precisely aligned resultant 3D images so that the same position in the specimen is compared. We could extract the osteocyte canaliculi and evaluate the mineral density of their surroundings. The degree of mineralization varied for each osteocyte lacuna and canaliculus. The multi-scan microscopic X-ray CT is a powerful tool for analyzing bone mineralization.

  6. Spinal uptake mimicking metastasis in SPECT/CT bone scan in a patient with superior vena cava obstruction.

    PubMed

    Rager, Olivier; Nkoulou, René; Garibotto, Valentina; Boudabbous, Sana; Arditi, Daniel

    2013-11-01

    A 46-year-old female patient with a mediastinal neuroendocrine carcinoma complicated by superior vena cava syndrome was referred for a bone metastatic workup. Bone scan with SPECT/CT showed several vertebral fixations without alterations on the unenhanced CT, but a CT scan with injection of contrast media showed vertebral densities matched to the lesions described on the SPECT/CT. This pattern confirmed presence of collateral paths through vertebral veins due to superior vena cava syndrome. Lack of metastases was confirmed by MRI.

  7. [Paget's disease mimicking metastatic prostate cancer on bone scan image : a case report].

    PubMed

    Fukushi, Ken; Koie, Takuya; Yamamoto, Hayato; Okamoto, Akiko; Imai, Atsushi; Hatakeyama, Shingo; Yoneyama, Takahiro; Hashimoto, Yasuhiro; Ohyama, Chikara

    2013-04-01

    A 61-year-old man was referred to our hospital complaining of elevated serum prostate-specific antigen (PSA) (5.1 ng/ml). Histopathologic diagnosis with trans-rectal prostate biopsy specimen was adenocarcinoma, Gleason score 4+5 = 9. Bone scintigraphy revealed an abnormal uptake on left coxal bone. The patient was diagnosed with prostate cancer with bone metastasis. He received androgen deprivation therapy for two years. Serum PSA decreased to an undetected level. However, the abnormal activity of left coxal bone lesion was not changed on bone scintigraphy. Coxal bone biopsy was performed. The bone lesion was histopathologically diagnosed as Paget's disease of bone.

  8. Effect of View, Scan Orientation and Analysis Volume on Digital Tomosynthesis (DTS) Based Textural Analysis of Bone.

    PubMed

    Kim, Woong; Oravec, Daniel; Divine, George W; Flynn, Michael J; Yeni, Yener N

    2017-01-12

    Digital tomosynthesis (DTS) derived textural parameters of human vertebral cancellous bone have been previously correlated to the finite element (FE) stiffness and 3D microstructure. The objective of this study was to optimize scanning configuration and use of multiple image slices in the analysis, so that FE stiffness prediction using DTS could be maximized. Forty vertebrae (T6, T8, T11, and L3) from ten cadavers (63-90 years) were scanned using microCT to obtain trabecular bone volume fraction (BV/TV) and FE stiffness. The vertebrae were then scanned using DTS anteroposteriorly (AP) and laterally (LM) while aligned axially (0°), transversely (90°) or obliquely (23°) to the superior-inferior axis of the vertebrae. From the serial DTS images, fractal dimension (FD), mean intercept length (MIL) and line fraction deviation (LFD) parameters were obtained from a 2D-single mid-stack location and 3D-multi-image stack. The DTS derived textural parameters were then correlated with FE stiffness using linear regression models within each scanning orientation. 3D-multi-image stack models obtained from Transverse-LM scanning orientation (90°) were most explanatory regardless of accounting for the effects of BV/TV. Therefore, DTS scanning perpendicular to the axis of the spine in an LM view is the preferred configuration for prediction of vertebral cancellous bone stiffness.

  9. Differences in acoustic impedance of fresh and embedded human trabecular bone samples-Scanning acoustic microscopy and numerical evaluation.

    PubMed

    Ojanen, Xiaowei; Töyräs, Juha; Inkinen, Satu I; Malo, Markus K H; Isaksson, Hanna; Jurvelin, Jukka S

    2016-09-01

    Trabecular bone samples are traditionally embedded and polished for scanning acoustic microscopy (SAM). The effect of sample processing, including dehydration, on the acoustic impedance of bone is unknown. In this study, acoustic impedance of human trabecular bone samples (n = 8) was experimentally assessed before (fresh) and after embedding using SAM and two-dimensional (2-D) finite-difference time domain simulations. Fresh samples were polished with sandpapers of different grit (P1000, P2500, and P4000). Experimental results indicated that acoustic impedance of samples increased significantly after embedding [mean values 3.7 MRayl (fresh), 6.1 MRayl (embedded), p < 0.001]. After polishing with different papers, no significant changes in acoustic impedance were found, even though higher mean values were detected after polishing with finer (P2500 and P4000) papers. A linear correlation (r = 0.854, p < 0.05) was found between the acoustic impedance values of embedded and fresh bone samples polished using P2500 SiC paper. In numerical simulations dehydration increased the acoustic impedance of trabecular bone (38%), whereas changes in surface roughness of bone had a minor effect on the acoustic impedance (-1.56%/0.1 μm). Thereby, the numerical simulations corroborated the experimental findings. In conclusion, acoustic impedance measurement of fresh trabecular bone is possible and may provide realistic material values similar to those of living bone.

  10. CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis

    PubMed Central

    Obert, Laurent; Peyron, Christelle; Boyer, Etienne; Menu, Gauthier; Loisel, François; Aubry, Sébastien

    2016-01-01

    Introduction: The shoulder arthroplasty brings satisfaction to patients in terms of quality of life and indolence. However whether anatomic implant or reverse, it does not escape from the loosening of the glenoid component. Moreover, optimal implantation is required to ensure the functional outcome without shortening of the arm. The purpose of this study is obtain CT scan evaluation of the glenoid bone stock in order to optimize glenoid component implantation and obtain a reference to determine optimal humeral component placement in case of humeral proximal fracture. Materials and methods: Between 2010 and 2011 we have analyzed 200 intact shoulder’s CT. We measured maximal and minimal width in the transverse plane of the glenoid, the distance from the pectoralis major (PM) tendon to the humeral head, the greater tubercle, change of curvature and the anatomical neck. Results: Mean maximum width was 27.4 ± 3.4 mm and mean minimum width was 15.5 ± 2.8 mm. Distances between upper edge of PM tendon to: humeral head, greater tubercle, change of curvature and anatomical neck were respectively: 67.6 ± 9.98 mm, 57.8 ± 10.3 mm, 28.7 ± 9 mm, and 34.2 ± 9.7 mm. Conclusion: Our study has produced an assessment of glenoid bone stock for optimal positioning of the glenoid implant but also to obtain a reference to determine the ideal location of the humeral component in the case of proximal humerus fracture. PMID:27716461

  11. Mapping dynamical mechanical properties of osteonal bone by scanning acoustic microscopy in time-of-flight mode.

    PubMed

    Blouin, Stéphane; Puchegger, Stephan; Roschger, Andreas; Berzlanovich, Andrea; Fratzl, Peter; Klaushofer, Klaus; Roschger, Paul

    2014-06-01

    An important determinant of mechanical properties of bone is Young's modulus and its variation in individual osteons of cortical bone tissue. Its mechanical behavior also depends on deformation rate owing to its visco- or poroelastic properties. We developed a method to measure dynamical mechanical properties of bulk bone tissue at osteonal level based on scanning acoustic microscopy (SAM) using time-of-flight (TOF) measurements in combination with quantitative backscattered electron imaging (qBEI). SAM-TOF yields local sound velocities and qBEI corresponding material densities together providing elastic properties. Osteons (n=55) were measured in three human femoral diaphyseal ground bone sections (∼ 30 µm in thickness). In addition, subchondral bone and mineralized articular cartilage were investigated. The mean mineral contents, the mean sound velocities, and the mean elastic modulus of the osteons ranged from 20 to 26 wt%, from 3,819 to 5,260 m/s, and from 21 to 44 GPa, respectively. There was a strong positive correlation between material density and sound velocity (Pearson's r=0.701; p<0.0001) of the osteons. Sound velocities between cartilage and bone was similar, though material density was higher in cartilage (+4.46%, p<0.0001). These results demonstrate the power of SAM-TOF to estimate dynamic mechanical properties of the bone materials at the osteonal level.

  12. Comparison of DXA Scans and Conventional X-rays for Spine Morphometry and Bone Age Determination in Children.

    PubMed

    Hoyer-Kuhn, Heike; Knoop, Kai; Semler, Oliver; Kuhr, Kathrin; Hellmich, Martin; Schoenau, Eckhard; Koerber, Friederike

    2016-01-01

    Conventional lateral spine and hand radiographs are the standard tools to evaluate vertebral morphometry and bone age in children. Beside bone mineral density analyses, dual-energy X-ray absorptiometry (DXA) measurements with lower radiation exposure provide high-resolution scans which are not approved for diagnostic purposes. Data about the comparability of conventional radiographs and DXA in children are missing yet. The purpose of the trial was to evaluate whether conventional hand and spine radiographs can be replaced by DXA scans to diminish radiation exposure. Thirty-eight children with osteogenesis imperfecta or secondary osteoporosis or short stature (male, n=20; age, 5.0-17.0 yr) were included and assessed once by additional DXA (GE iDXA) of the spine or the left hand. Intraclass correlation coefficients (ICCs) were used to express agreement between X-ray and iDXA assessment. Evaluation of the spine morphometry showed reasonable agreement between iDXA and radiography (ICC for fish-shape, 0.75; for wedge-shape, 0.65; and for compression fractures, 0.70). Bone age determination showed excellent agreement between iDXA and radiography (ICC, 0.97). IDXA-scans of the spine in a pediatric population should be used not only to assess bone mineral density but also to evaluate anatomic structures and vertebral morphometry. Therefore, iDXA can replace some radiographs in children with skeletal diseases.

  13. Evaluation of extremity pain in children using technetium-99m MDP bone scan: A general hospital experience

    SciTech Connect

    Park, H.M.; Rothschild, P.A.; Kernek, C.B.

    1984-01-01

    This study was undertaken to evaluate the efficacy of three-phase bone scan in detection of significant pathology i.e., osteomyelitis (OM), septic joint, cellulitis, etc., in children with symptoms of extremity pain. A total of 100 consecutive patients (age 9 days - 16 yrs, 63 boys and 37 girls) were studied. The authors reviewed their scans, x-rays and hospital records. The final diagnoses were based on the findings of needle aspiration, surgical drainage, biopsy, culture, and on the therapeutic response. In 87%, sufficiently long clinical follow-up was available to confirm the final diagnoses. In the remaining 13%, the symptoms resolved quickly and follow-up was not felt necessary. The scan was essential in pinpointing the lesions in pts with referred or nonlocalizing extremity pain. The +ve and -ve predictive values of the scan and OM were 89% and 96% respectively. One spiral fracture was misinterpreted as diffuse OM. One ''Subacute epiphyseal OM'' was not detected. In two cases, cellulitis and septic joint obscured underlying OM. Prior antibotic therapy resulted in one equivocal scan. Although less sensitive (29%) in early OM, radiographs play an important complimentary role. Bone scans detected underlying pathology for extremity pain in 61% of all pts studied.

  14. Extraosseous myocardial uptake incidentally detected during bone scan: report of three cases and a systematic literature review of extraosseous uptake.

    PubMed

    Caobelli, Federico; Paghera, Barbara; Pizzocaro, Claudio; Guerra, Ugo Paolo

    2013-01-01

    Bone scintigraphy is widely considered as an important technique able to investigate various pathological conditions of the skeletal system. Many unexpected extraosseous uptakes have been reported in literature. We present here three cases of unexpected 99mTc-oxidronate (HDP) myocardial extraosseous uptakes in patients undergoing bone scan for staging purposes. In particular, we present the first reported case ofa myocardial uptake in a patient with IgM-related amyloidosis. Subsequently, we perform a review of the existing literature about extraosseous uptakes.

  15. The nanometre-scale physiology of bone: steric modelling and scanning transmission electron microscopy of collagen–mineral structure

    PubMed Central

    Alexander, Benjamin; Daulton, Tyrone L.; Genin, Guy M.; Lipner, Justin; Pasteris, Jill D.; Wopenka, Brigitte; Thomopoulos, Stavros

    2012-01-01

    The nanometre-scale structure of collagen and bioapatite within bone establishes bone's physical properties, including strength and toughness. However, the nanostructural organization within bone is not well known and is debated. Widely accepted models hypothesize that apatite mineral (‘bioapatite’) is present predominantly inside collagen fibrils: in ‘gap channels’ between abutting collagen molecules, and in ‘intermolecular spaces’ between adjacent collagen molecules. However, recent studies report evidence of substantial extrafibrillar bioapatite, challenging this hypothesis. We studied the nanostructure of bioapatite and collagen in mouse bones by scanning transmission electron microscopy (STEM) using electron energy loss spectroscopy and high-angle annular dark-field imaging. Additionally, we developed a steric model to estimate the packing density of bioapatite within gap channels. Our steric model and STEM results constrain the fraction of total bioapatite in bone that is distributed within fibrils at less than or equal to 0.42 inside gap channels and less than or equal to 0.28 inside intermolecular overlap regions. Therefore, a significant fraction of bone's bioapatite (greater than or equal to 0.3) must be external to the fibrils. Furthermore, we observe extrafibrillar bioapatite between non-mineralized collagen fibrils, suggesting that initial bioapatite nucleation and growth are not confined to the gap channels as hypothesized in some models. These results have important implications for the mechanics of partially mineralized and developing tissues. PMID:22345156

  16. The nanometre-scale physiology of bone: steric modelling and scanning transmission electron microscopy of collagen-mineral structure.

    PubMed

    Alexander, Benjamin; Daulton, Tyrone L; Genin, Guy M; Lipner, Justin; Pasteris, Jill D; Wopenka, Brigitte; Thomopoulos, Stavros

    2012-08-07

    The nanometre-scale structure of collagen and bioapatite within bone establishes bone's physical properties, including strength and toughness. However, the nanostructural organization within bone is not well known and is debated. Widely accepted models hypothesize that apatite mineral ('bioapatite') is present predominantly inside collagen fibrils: in 'gap channels' between abutting collagen molecules, and in 'intermolecular spaces' between adjacent collagen molecules. However, recent studies report evidence of substantial extrafibrillar bioapatite, challenging this hypothesis. We studied the nanostructure of bioapatite and collagen in mouse bones by scanning transmission electron microscopy (STEM) using electron energy loss spectroscopy and high-angle annular dark-field imaging. Additionally, we developed a steric model to estimate the packing density of bioapatite within gap channels. Our steric model and STEM results constrain the fraction of total bioapatite in bone that is distributed within fibrils at less than or equal to 0.42 inside gap channels and less than or equal to 0.28 inside intermolecular overlap regions. Therefore, a significant fraction of bone's bioapatite (greater than or equal to 0.3) must be external to the fibrils. Furthermore, we observe extrafibrillar bioapatite between non-mineralized collagen fibrils, suggesting that initial bioapatite nucleation and growth are not confined to the gap channels as hypothesized in some models. These results have important implications for the mechanics of partially mineralized and developing tissues.

  17. [Total body MRI in early detection of bone metastasis and its indication in comparison to bone scan and other imaging techniques].

    PubMed

    Luna, Antonio; Vilanova, Joan C; Alcalá Mata, Lidia

    2015-04-01

    Bone metastases are a recognized prognostic factor in patients with prostate cancer. Currently, Tc99 bone scan is the most frequently used imaging technique for their detection, showing a high sensitivity but a limited specificity. Thus, new morphological and mainly functional imaging techniques based on PET and MRI, or hybrid techniques such as PET-CT or PET-MRI have been introduced to improve metastases detection, estimation of total tumor load and for therapeutic monitoring. In this clinical scenario, total body MRI has arisen as a very promising technique in detection and therapeutic monitoring of bone metastases of prostate cancer, because it neither uses ionizing radiation nor needs the administration of contrast media. The incorporation of MR diffusion to the morphologic total body MRI protocols provides functional information, improving the sensitivity in oncological lesions detection in general and osteolytic bone metastases of PCa in particular. Its integration in protocols with morphological sequences and its quantification through ADC maps enables us to better understand metastatic bone disease patterns and their changes with different therapies. Total body D MRI enables the early classification of the response to treatment with evident advantages over other imaging techniques and the purely morphological approach with MRI. In any case, prospective and cost-effectiveness studies are necessary to establish the role of total-body D MRI in the management of patients with PCa.

  18. Bone scan usefulness in patients with painful hip or knee prosthesis: 10 situations that can cause pain, other than loosening and infection.

    PubMed

    Vaz, Sofia; Ferreira, Teresa C; Salgado, Lucília; Paycha, Frédéric

    2017-02-01

    In recent years, with the higher median life expectancy, the number of hip and knee replacements has increased. Clinical examination and morphological studies are essential to evaluate patients with a painful arthroplasty. Nuclear medicine examinations also play an important role, their main usefulness being the exclusion of prosthesis complications. Nevertheless, conventional examinations, namely bone scan and white blood cell scintigraphy, can also identify complications, such as loosening and infection. This study describes the normal and pathologic patterns of a bone scan and exemplifies ten common situations that can cause pain in patients with hip or knee arthroplasty, other than loosening and infection, which can be disclosed on a bone scintigraphy. The ten situations that should be considered and looked for when analysing a bone scan are: referred pain, patellofemoral pain syndrome, fractures, fissures, abscess/haematoma, bone insert behaviour, heterotopic ossification, greater trochanter pseudarthrosis, osteoarthritis extension in a knee with an unicompartmental prosthesis, and systemic disease with bone involvement.

  19. The relationship between skeletal-related events and bone scan index for the treatment of bone metastasis with breast cancer patients.

    PubMed

    Iwase, Toshiaki; Yamamoto, Naohito; Ichihara, Hironori; Togawa, Takashi; Nagashima, Takeshi; Miyazaki, Masaru

    2014-12-01

    The aim of the present study was to investigate the relationships between the automated bone scan index (aBSI) and skeletal-related events (SRE) in breast cancer patients with bone metastasis. A computer-aided software (BONENAVI™) that was developed using an Artificial Neural Network (Artificial Neural Network) was used for the present analysis. Forty-five patients diagnosed with bone metastasis due to breast cancer from April 2005 through March 2013 were retrospectively analyzed. Before and after the time of initial treatment, aBSI, Artificial Neural Network score, and hotspot number were calculated, and the relationships between these scores and SRE were analyzed. Twenty cases showed decreased (improved) aBSI values after initial treatment (Group A), and 25 cases showed unchanged/increased (worsened) aBSI values (Group B). Chi-square analysis revealed a significant difference in incident numbers of SRE between the two groups--one case in Group A and 12 in Group B (P<0.001). Event-free survival was significantly shorter in Group B (hazard ratio: 8.31, 95% CI: 1.33-12.14, log-rank test; P<0.05). The groups were also divided by the results of 2 radiologists' visual scan interpretations, and no significant differences were shown in the number of SRE (P=0.82, P=0.10). When correlation analyses were performed between aBSI and bone metabolic or tumor markers, alkaline phosphatase was significantly correlated with aBSI at the time of initial treatment (R=0.69, P<0.05). In conclusion, aBSI is proposed as a useful and objective imaging biomarker in the detection of breast-cancer patients with bone metastasis at high risk of SRE.

  20. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    SciTech Connect

    Alexander, J.E.; Seibert, J.J.; Aronson, J.; Williamson, S.L.; Glasier, C.M.; Rodgers, A.B.; Corbitt, S.L.

    1988-04-01

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck.

  1. The Role of 18F-Sodium Fluoride PET/CT Bone Scans in the Diagnosis of Metastatic Bone Disease from Breast and Prostate Cancer.

    PubMed

    Kulshrestha, Randeep Kumar; Vinjamuri, Sobhan; England, Andrew; Nightingale, Julie; Hogg, Peter

    2016-12-01

    We describe the role of (18)F-sodium fluoride ((18)F-NaF) PET/CT bone scanning in the staging of breast and prostate cancer. (18)F-NaF PET was initially utilized as a bone scanning agent in the 1960s and early 1970s, however, its use was restricted by the then-available γ-cameras. The advent of hybrid PET/CT cameras in the late 1990s has shown a resurgence of interest in its use and role. After a brief introduction, this paper describes the radiopharmaceutical properties, dosimetry, pharmacokinetics, and mechanism of uptake of (18)F-NaF. The performance of (18)F-NaF PET/CT is then compared with that of conventional bone scintigraphy using current evidence from the literature. Strengths and weaknesses of (18)F-NaF PET/CT imaging are highlighted. Clinical examples of improved accuracy of diagnosis and impact on patient management are illustrated. Limitations of (18)F-NaF PET/CT imaging are outlined.

  2. [The diagnostic value of 99mTc-MDP bone scan and computed tomography for bone metastases of breast cancer: a systematic review].

    PubMed

    Yu, Yanxia; Kuang, Anren

    2014-06-01

    According to the inclusion and exclusion criteria, we searched for relevant original articles in some big Chinese and English databases. The qualities of the studies were evaluated with QUADAS quality assessment tool. A software program, Meta-disc, was used to obtain the pooled estimates and heterogeneity test for sensitivity, specificity, SROC curve, and so on. Finally the 17 article were included. On a per-patient basis, the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (LR+), negative likelihood ratio (LR-), diagnostic odds ratio (DOR), Q*, SROC area under curve for 99mTc-MDP bone scan and computed tomography (CT) were 0. 87 and 0.99, 0.81 and 0.98, 3.88 and 13.86, 0.2 and 0.03, 27.73 and 612.17, 0.8418 and 0.9732, 0.9097 and 0.9952, respectively. On a per-focus basis, the pooled SEN, SPE, LR+, LR-, DOR, Q*, SROC area under curve for 99mTc-MDP bone scan was 0.86, 0.97, 13.32, 0.16, 102.4, 0.8944, 0.9528, respectively. For CT, only 1 article were included. This paper demonstrate: whether 99mTc-MDP or CT both have high diagnostic efficiency for bone metastase of breast cancer.

  3. Template-based automatic extraction of the joint space of foot bones from CT scan

    NASA Astrophysics Data System (ADS)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  4. Normalized volume of interest selection and measurement of bone volume in microCT scans.

    PubMed

    Snoeks, T J A; Kaijzel, E L; Que, I; Mol, I M; Löwik, C W G M; Dijkstra, J

    2011-12-01

    Quantification of osteolytic lesions in bone is pivotal in the research of metastatic bone disease in small animal models. Osteolytic lesions are quantified using 2D X-ray photographs, which often neglects to take into account any changes in 3D structure. Furthermore, measurement errors are inadvertently introduced when a region of interest with predefined dimensions is used during MicroCT analysis. To study osteolytic processes, a normalized method of selecting a region of interest is required. Here we describe a new method to select volumes of interest in a normalized way regardless of curvature, fractures or dislocations within the bone. In addition, this method enables the user to visualize normalized cross sections in an exact 90° angle or along the longitudinal axis of bone, at any given point. As a result, the user can compare measurements of diameter, volume and structure between different bones in a normalized manner.

  5. Comparison of macroscopic and microscopic (stereomicroscopy and scanning electron microscopy) features of bone lesions due to hatchet hacking trauma.

    PubMed

    Nogueira, Luísa; Quatrehomme, Gérald; Bertrand, Marie-France; Rallon, Christophe; Ceinos, Romain; du Jardin, Philippe; Adalian, Pascal; Alunni, Véronique

    2017-03-01

    This experimental study examined the lesions produced by a hatchet on human bones (tibiae). A total of 30 lesions were produced and examined macroscopically (naked eye) and by stereomicroscopy. 13 of them were also analyzed using scanning electron microscopy. The general shape of the lesion, both edges, both walls, the kerf floor and the extremities were described. The length and maximum width of the lesions were also recorded. The microscopic analysis of the lesions led to the description of a sharp-blunt mechanism. Specific criteria were identified (lateral pushing back, fragmentation of the upraising, fossa dug laterally to the edge and vertical striae) enabling the forensic expert to conclude that a hacking instrument was used. These criteria are easily identifiable using scanning electron microscopy, but can also be observed with stereomicroscopy. Overall, lateral pushing back and vertical striae visible using stereomicroscopy and scanning electron microscopy signal the use of a hacking tool.

  6. Diffuse bone metastases on (68)Ga-PSMA PET-CT in a patient with prostate cancer and normal bone scan.

    PubMed

    Lavalaye, J; Kaldeway, P; van Melick, H H E

    2016-07-01

    A 75-year-old patient was diagnosed with a Gleason 9 prostate carcinoma. His PSA level was 50.4 ng/ml. Routine bone scintigraphy was negative for metastasis (a). Due to the high tumour grading and relatively high PSA level, (68)Ga-PSMA PET-CT was ordered to rule out distant metastases. This scan showed numerous skeletal lesions with high tracer accumulation as sign of diffuse osseous metastases (b). On low-dose CT there were no signs of sclerosis (c). (68)Ga-PSMA PET-CT also showed high uptake in the prostate and in para-iliac and para-aortal lymph nodes, without lymph node enlargement. No bone biopsy was obtained to confirm the metastases. Due to this result, the treatment plan was changed to systemic therapy, instead of local therapy.

  7. CT Scans

    MedlinePlus

    ... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...

  8. Association between bone indices assessed by DXA, HR-pQCT and QCT scans in post-menopausal women.

    PubMed

    Amstrup, Anne Kristine; Jakobsen, Niels Frederik Breum; Moser, Emil; Sikjaer, Tanja; Mosekilde, Leif; Rejnmark, Lars

    2016-11-01

    Quantitative computed tomography (QCT), high-resolution peripheral QCT (HR-pQCT) and dual X-ray absorptiometry (DXA) scans are commonly used when assessing bone mass and structure in patients with osteoporosis. Depending on the imaging technique and measuring site, different information on bone quality is obtained. How well these techniques correlate when assessing central as well as distal skeletal sites has not been carefully assessed to date. One hundred and twenty-five post-menopausal women aged 56-82 (mean 63) years were studied using DXA scans (spine, hip, whole body and forearm), including trabecular bone score (TBS), QCT scans (spine and hip) and HR-pQCT scans (distal radius and tibia). Central site measurements of areal bone mineral density (aBMD) by DXA and volumetric BMD (vBMD) by QCT correlated significantly at the hip (r = 0.74, p < 0.01). Distal site measurements of density at the radius as assessed by DXA and HR-pQCT were also associated (r = 0.74, p < 0.01). Correlations between distal and central site measurements of the hip and of the tibia and radius showed weak to moderate correlation between vBMD by HR-pQCT and QCT (r = -0.27 to 0.54). TBS correlated with QCT at the lumbar spine (r = 0.35) and to trabecular indices of HR-pQCT at the radius and tibia (r = -0.16 to 0.31, p < 0.01). There was moderate to strong agreement between measuring techniques when assessing the same skeletal site. However, when assessing correlations between central and distal sites, the associations were only weak to moderate. Our data suggest that the various techniques measure different characteristics of the bone, and may therefore be used in addition to rather than as a replacment for imaging in clinical practice.

  9. Which metabolic imaging, besides bone scan with 99mTc-phosphonates, for detecting and evaluating bone metastases in prostatic cancer patients? An open discussion.

    PubMed

    Bombardieri, E; Setti, L; Kirienko, M; Antunovic, L; Guglielmo, P; Ciocia, G

    2015-12-01

    Prostate cancer bone metastases occur frequently in advanced cancer and this is matter of particular attention, due to the great impact on patient's management and considering that a lot of new emerging therapeutic options have been recently introduced. Imaging bone metastases is essential to localize lesions, to establish their size and number, to study characteristics and changes during therapy. Besides radiological imaging, nuclear medicine modalities can image their features and offer additional information about their metabolic behaviour. They can be classified according to physical characteristics, type of detection, mechanism of uptake, availability for daily use. The physiopathology of metastases formation and the mechanisms of tracer uptake are essential to understand the interpretation of nuclear medicine images. Therefore, radiopharmaceuticals for bone metastases can be classified in agents targeting bone (99mTc-phosphonates, 18F-fluoride) and those targeting prostatic cancer cells (18F-fluoromethylcholine, 11C-choline, 18F-fluorodeoxyglucose). The modalities using the first group of tracers are planar bone scan, SPECT or SPECT/CT with 99mTc-diphosphonates, and 18F-fluoride PET/CT, while the modalities using the second group include 18F/11C-choline derivatives PET/CT, 18F-FDG PET/CT and PET/CT scans with several other radiopharmaceuticals described in the literature, such as 18F/11C-acetate derivatives, 18F-fluoro-5α-dihydrotestosterone (FDHT), 18F-anti-1-amino-3-fluorocyclobutane-1-carboxylic acid (FACBC), 18F-2'-fluoro-5-methyl-1-β-D-arabinofuranosyluracil (FMAU) and 68Ga-labeled-prostate specific membrane antigen (PMSA) PET/TC. However, since data on clinical validation for these last novel modalities are not conclusive and/or are not still sufficient in number, at present they can be still considered as promising tools under evaluation. The present paper considers the nuclear modalities today available for the clinical routine. This overview wants

  10. Extensive visceral calcification demonstrated on Tc-99m MDP bone scan in patient with sphenoidal sinus carcinoma and hypercalcaemia of malignancy: a bad prognostic sign.

    PubMed

    Usmani, S; Khan, H A; Abu Huda, F; Al Nafisi, N; Al Mohannadi, S

    2011-01-01

    Sphenoidal sinus carcinoma is a rare cause of hypercalcemia of malignancy. We report on a 37-year-old male with sphenoidal sinus carcinoma with intracranial extension who developed hypercalcemia of malignancy with progressing disease and demonstrated diffuse metastatic visceral calcifications of lungs, myocardium, stomach, kidneys and thyroid on follow-up 99mTc-methylene diphosphonate bone scan. In the absence of extensive skeletal metastases, bone scan help confirm humoral nature of hypercalcaeimia.

  11. Biomechanical Role of Bone Anisotropy Estimated on Clinical CT Scans by Image Registration.

    PubMed

    Taghizadeh, Elham; Reyes, Mauricio; Zysset, Philippe; Latypova, Adeliya; Terrier, Alexandre; Büchler, Philippe

    2016-08-01

    Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

  12. Role of (99m)Tc-MDP bone scan in the diagnosis of Erdheim-Chester disease.

    PubMed

    Mukherjee, Anirban; Damle, Nishikant; Bal, Chandrasekhar; Arora, Arundeep; Singhal, Abhinav; Tripathi, Madhavi; Peepre, Karan

    2014-07-01

    Erdheim-Chester disease (ECD) is a rare systemic non-Langerhans cell histiocytosis. It is a progressive disease of unknown etiology. The (99m)technetium-methylene diphosphonate ((99m)Tc-MDP) bone scan is useful in finding the sites of involvement in the skeleton and is helpful in excluding other causes of bony pain. Also a scintigraphic pattern consistent with ECD should alert the physician to evaluate the patient for visceral sites of involvement using fludeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), as this is known to be fatal at times.

  13. Distal metacarpal bone mineral density by dual energy X-ray absorptiometry (DEXA) scan. Methodological investigation and application in rheumatoid arthritis.

    PubMed

    Florescu, A; Pødenphant, J; Thamsborg, G; Hansen, M; Leffers, A M; Andersen, V

    1993-01-01

    Dual energy X-ray absorptiometry scanning was performed along the axis of the third metacarpal bone of the non-dominant hand and including metacarpal bones 2, 3, 4 and 5. The Bone Mineral Density (BMD) was calculated for the distal 1/4 of each metacarpal bone. Ten patients with seropositive, erosive rheumatoid arthritis (RA) and 10 healthy, sex- and age-matched persons were investigated twice. The average BMD in RA patients was 73.6% of the value found in normals. The coefficient of variation on double determinations (in patients and controls) was 0.9-3.0%. We suggest that dual energy X-ray absorptiometry scanning with the scanning procedure proposed here may be an important instrument for the quantification of disease progression.

  14. Discordance between MRI and bone scan findings in a child with acute complicated osteomyelitis: scintigraphic features that contribute to the early diagnosis.

    PubMed

    Mpalaris, V; Arsos, G; Iakovou, I; Dalpa, E; Karatzas, N

    2014-01-01

    Early diagnosis and prompt treatment of acute osteomyelitis are of paramount importance in children because they can prevent irreversible bone damage. Magnetic resonance imaging (MRI) with its superior spatial resolution and lack of ionizing radiation is routinely preferred over bone scan for this purpose. Increased blood flow, hyperemia and focally increased tracer uptake shown by "three phase" bone scan are the typical scintigraphic findings of acute osteomyelitis. In addition, diffuse uptake along the shaft of long bones and focal "cold" lesions are two special features that may be highly suggestive of infective periostitis, soft tissue sepsis and subperiosteal abscess formation, due to the loose attachment of periosteum to bone during childhood. We present a case of complicated osteomyelitis in a child with inconclusive MRI correctly diagnosed on the basis of these special scintigraphic findings resulting in treatment change from double i.v. Vancomycin--Ceftriaxone scheme to surgical intervention.

  15. Diffuse pulmonary ossification detected by bone scanning with Tc-99m hydroxymethylene diphosphate

    SciTech Connect

    Saks, D.A.; McClees, E.C.; Fajman, W.A.; Hollinger, W.M.; Gilman, M.J.

    1984-10-01

    Diffuse pulmonary ossification (DPO) is a rare pathologic finding of heterotropic bone formation within the lungs. It has been associated with mitral stenosis, chronic left ventricular failure, interstitial fibrosis, metastatic breast cancer, pulmonary amyloidosis, histoplasmosis, and chronic busulfan therapy. This patient represents a case associated with Placidyl use.

  16. Astronaut Bone Medical Standards Derived from Finite Element (FE) Models of QCT Scans from Population Studies

    NASA Technical Reports Server (NTRS)

    Sibonga, J. D.; Feiveson, A. H.

    2014-01-01

    This work was accomplished in support of the Finite Element [FE] Strength Task Group, NASA Johnson Space Center [JSC], Houston, TX. This group was charged with the task of developing rules for using finite-element [FE] bone-strength measures to construct operating bands for bone health that are relevant to astronauts following exposure to spaceflight. FE modeling is a computational tool used by engineers to estimate the failure loads of complex structures. Recently, some engineers have used this tool to characterize the failure loads of the hip in population studies that also monitored fracture outcomes. A Directed Research Task was authorized in July, 2012 to investigate FE data from these population studies to derive these proposed standards of bone health as a function of age and gender. The proposed standards make use of an FE-based index that integrates multiple contributors to bone strength, an expanded evaluation that is critical after an astronaut is exposed to spaceflight. The current index of bone health used by NASA is the measurement of areal BMD. There was a concern voiced by a research and clinical advisory panel that the sole use of areal BMD would be insufficient to fully evaluate the effects of spaceflight on the hip. Hence, NASA may not have a full understanding of fracture risk, both during and after a mission, and may be poorly estimating in-flight countermeasure efficacy. The FE Strength Task Group - composed of principal investigators of the aforementioned population studies and of FE modelers -donated some of its population QCT data to estimate of hip bone strength by FE modeling for this specific purpose. Consequently, Human Health Countermeasures [HHC] has compiled a dataset of FE hip strengths, generated by a single FE modeling approach, from human subjects (approx.1060) with ages covering the age range of the astronauts. The dataset has been analyzed to generate a set of FE strength cutoffs for the following scenarios: a) Qualify an

  17. Now & Then: From Cashier to Scan Coordinator; From Stones to Bones to PC Clones.

    ERIC Educational Resources Information Center

    Barnes, Sue; Michalowicz, Karen Dee

    1994-01-01

    Discusses the changes in the scanning of food and the current use of computer technology and UPC bar codes in a grocery store and traces the history of calculating tools from the use of fingers, abacus, slide rule, calculators, and computers. Includes reproducible student activity sheets. (MKR)

  18. Morphometric analysis of osteonal architecture in bones from healthy young human male subjects using scanning electron microscopy.

    PubMed

    Pazzaglia, Ugo E; Congiu, Terenzio; Pienazza, Alberto; Zakaria, Mohammed; Gnecchi, Michele; Dell'orbo, Carlo

    2013-09-01

    The shape and structure of bones is a topic that has been studied for a long time by morphologists and biologists with the goal of explaining the laws governing their development, aging and pathology. The osteonal architecture of tibial and femoral mid-diaphyses was examined morphometrically with scanning electron microscopy in four healthy young male subjects. In transverse sections of the mid-diaphysis, the total area of the anterior, posterior, lateral and medial cortex sectors was measured and analysed for osteonal parameters including osteon number and density, osteon total and bone area and vascular space area. Osteons were grouped into four classes including cutting heads (A), transversely cut osteons (B), longitudinally cut osteons (C) and sealed osteons (D). The morphometric parameters were compared between the inner (endosteal) and outer (periosteal) half of the cortex. Of 5927 examined osteons, 24.4% cutting heads, 71.1% transversely cut osteons, 2.3% longitudinally cut osteons and 2.2% sealed osteons were found. The interosteonic bone (measured as the area in a lamellar system that has lost contact with its own central canal) corresponded to 51.2% of the endosteal and 52.4% of the periosteal half-cortex. The mean number of class A cutting heads and class B osteons was significantly higher in the periosteal than in the endosteal half-cortex (P < 0.001 and P < 0.05, respectively), whereas there was no significant difference in density. The mean osteon total area, osteon bone area and vascular space area of both classes A and B were significantly higher (P < 0.001 for all three parameters) in the endosteal than in the periosteal half-cortex. The significant differences between the two layers of the cortex suggest that the osteoclast activity is distributed throughout the whole cortical thickness, with more numerous excavations in the external layer, but larger resorption lacunae closer to the marrow canal. A randomly selected population of 109 intact

  19. A long femur scan field does not alter proximal femur bone mineral density measurements by dual-energy X-ray absorptiometry.

    PubMed

    McKiernan, Fergus Eoin; Hocking, Jane; Cournoyer, Susan; Berg, Richard L; Linneman, James

    2011-01-01

    A longer dual-energy X-ray absorptiometry (DXA) femur scan field might be useful for the detection of atypical, subtrochanteric femur fractures (ASFF). Thirty adult subjects underwent triplicate measures of femoral neck (FN) and total hip (TH) bone mineral density (BMD) by DXA using a conventional (i.e., short) and a longer femur scan field. Differences in measured BMD between the 2 scan field lengths were small and less than the precision error inherent in DXA testing. A longer proximal femur scan field does not substantially alter BMD measurements made at the FN and TH and may be useful for the detection of ASFF in clinical practice.

  20. Scanning electron image analysis to monitor of implant degradation and host healing following implantation of a drug-eluting bone graft void filler - biomed 2013.

    PubMed

    Davidoff, Sherry N; Lawson, Scott T; Grainger, David W; Brooks, Amanda E

    2013-01-01

    Osteomyelitis is most commonly caused by Staphylococcus aureus and often sourced during orthopedic surgical intervention. Successful treatment or prevention of this bone penetrating infection requires antibiotics be delivered in excess of the minimal inhibitory concentration to prohibit the growth of the causative organism for sufficient duration. Unfortunately, current standard-of-care antibiotic therapies, administered via intravenous or oral delivery, suffer not only from systemic toxicity and low patient compliance but also provide insufficient local concentrations for therapy. To overcome these clinical inadequacies, a synthetic bone graft material was coated with an antibiotic (tobramycin)-releasing polymer (polycaprolactone) matrix to create a polymer-controlled antibiotic- releasing combination therapy for use as a bone void filler in orthopedic surgeries. Even though this local delivery strategy allows antibiotic delivery over a clinically relevant time frame to prevent infection, complete healing requires the host bone to infiltrate and reabsorb the bone void filler, ultimately replacing the defect with healthy tissue. Unfortunately, the same polymer matrix that allows for controlled local antibiotic delivery may also discourage host bone healing. Efficient orthopedic healing requires the rate of polymer degradation to match the rate of host-bone infiltration. Current imaging techniques, such as histological staining and x-ray imaging, are insufficient to simultaneously assess polymer degradation and host bone integration. Alternative techniques relying on backscatter electron detection during scanning electron microscopy (SEM) imaging may allow a visual differentiation between host bone, synthetic bone, and polymer. Analysis of backscattered SEM images was automated using a custom MATLAB program to determine the ratio of bone to polymer based upon the contrast between the bone (white) and polymer (dark grey). By collecting images of the implant over time

  1. Neonatal Death Dwarfism in a Girl with Distinctive Bone Dysplasia Compatible with Grebe Chondrodysplasia: Analysis by CT Scan-based Phenotype

    PubMed Central

    Al Kaissi, Ali; Chehida, Farid Ben; Ganger, Rudolf; Grill, Franz

    2014-01-01

    We report on a female fetus noted to have severe malformative type of skeletal dysplasia on ultrasonography done at 35 weeks gestation. The girl died shortly after birth. Clinical examination showed a fetus with severe dwarfism, extensive long and short bones, and bone deficiencies associated with multiple dislocations. Computed tomography (CT) scan-based phenotype showed a complex constellation of malformations consistent with the diagnosis of Grebe syndrome. Parents being first cousins (consanguineous marriage) strongly suggests autosomal recessive pattern of inheritance. To our knowledge, this is the first report of neonatal death dwarfism of Grebe syndrome analyzed by CT scan-based phenotype. PMID:25337439

  2. Scanning electron microscope analysis of gunshot defects to bone: an underutilized source of information on ballistic trauma.

    PubMed

    Rickman, John M; Smith, Martin J

    2014-11-01

    Recent years have seen increasing involvement by forensic anthropologists in the interpretation of skeletal trauma. With regard to ballistic injuries, there is now a large literature detailing gross features of such trauma; however, less attention has been given to microscopic characteristics. This article presents analysis of experimentally induced gunshot trauma in animal bone (Bos taurus scapulae) using full metal jacket (FMJ), soft point (SP), and captive bolt projectiles. The results were examined using scanning electron microscopy (SEM). Additional analysis was conducted on a purported parietal gunshot lesion in a human cranial specimen. A range of features was observed in these samples suggesting that fibrolamellar bone response to projectile impact is analogous to that observed in synthetic composite laminates. The results indicate that direction of bullet travel can be discerned microscopically even when it is ambiguous on gross examination. It was also possible to distinguish SP from FMJ lesions. SEM analysis is therefore recommended as a previously underexploited tool in the analysis of ballistic trauma.

  3. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    SciTech Connect

    Hunter, J.C.; Hattner, R.S.; Murray, W.R.; Genant, H.K.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery and seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.

  4. Non-contact scanning diffuse correlation tomography system for three-dimensional blood flow imaging in a murine bone graft model.

    PubMed

    Han, Songfeng; Johansson, Johannes; Mireles, Miguel; Proctor, Ashley R; Hoffman, Michael D; Vella, Joseph B; Benoit, Danielle S W; Durduran, Turgut; Choe, Regine

    2015-07-01

    A non-contact galvanometer-based optical scanning system for diffuse correlation tomography was developed for monitoring bone graft healing in a murine femur model. A linear image reconstruction algorithm for diffuse correlation tomography was tested using finite-element method based simulated data and experimental data from a femur or a tube suspended in a homogeneous liquid phantom. Finally, the non-contact system was utilized to monitor in vivo blood flow changes prior to and one week after bone graft transplantation within murine femurs. Localized blood flow changes were observed in three mice, demonstrating a potential for quantification of longitudinal blood flow associated with bone graft healing.

  5. Bone mineral content measured by DEXA scan in preterm neonates receiving total parentral nutrition with and without phosphorus supplementation.

    PubMed

    Awad, H A; Farid, T M; Khafagy, S M; Nofal, R I

    2010-09-15

    Intravenous phosphorus preparation was not available in Egypt till recently. So we aimed to prove the positive effect of adding intravenous phosphorus to total parentral nutrition (TPN) on calcium (Ca) and phosphorus (PO4) metabolism ofpreterm neonates by measuring bone mineral content (BMC) using DEXA scan. A case-control study was conducted in NICU of Obstetric and Gynecology Hospital of Ain Shams University which is a tertiary care unit in Cairo. Thirty preterm infants were prospectively enrolled in the study divided into 2 groups; 15 preterm infants received TPN with phosphorus supplementation (group 1) and 15 preterm received TPN without phosphorus supplementation (group 2). Serum Ca, PO4 and alkaline phosphatase (ALP) assay were done together with urinary calcium/creatinine (Ca/Cr) ratio, abdominal ultrasound and DEXA scan. There were no significant difference regarding serum Ca and PO4 between group 1 and 2. Yet there were highly significant increase in serum ALP and urinary Ca/Cr ratio in group 2 compared to group 1 (p = 0.001). Also group 1 had significantly higher BMC compared to group 2 even with TPN duration less than 15 days (p = 0.001). BMC was significantly positively correlated with G.A and B.W in both groups and was significantly negatively correlated with serum ALP in group 2 and with urinary calcium/creatinine ratio in group 1. Duration of TPN as short as 2 weeks can affect negatively the BMC as documented by DEXA scan in preterm infants receiving TPN without phosphorus supplementation.

  6. Bone Densitometry (Bone Density Scan)

    MedlinePlus

    ... x-rays. top of page What does the equipment look like? There are two types of DEXA equipment: a central device and a peripheral device. Central ... within 10 to 30 minutes, depending on the equipment used and the parts of the body being ...

  7. Bone

    NASA Astrophysics Data System (ADS)

    Helmberger, Thomas K.; Hoffmann, Ralf-Thorsten

    The typical clinical signs in bone tumours are pain, destruction and destabilization, immobilization, neurologic deficits, and finally functional impairment. Primary malignant bone tumours are a rare entity, accounting for about 0.2% of all malignancies. Also benign primary bone tumours are in total rare and mostly asymptomatic. The most common symptomatic benign bone tumour is osteoid osteoma with an incidence of 1:2000.

  8. Scanning Electron Microscopy Reveals Two Distinct Classes of Erythroblastic Island Isolated from Adult Mammalian Bone Marrow.

    PubMed

    Yeo, Jia Hao; McAllan, Bronwyn M; Fraser, Stuart T

    2016-04-01

    Erythroblastic islands are multicellular clusters in which a central macrophage supports the development and maturation of red blood cell (erythroid) progenitors. These clusters play crucial roles in the pathogenesis observed in animal models of hematological disorders. The precise structure and function of erythroblastic islands is poorly understood. Here, we have combined scanning electron microscopy and immuno-gold labeling of surface proteins to develop a better understanding of the ultrastructure of these multicellular clusters. The erythroid-specific surface antigen Ter-119 and the transferrin receptor CD71 exhibited distinct patterns of protein sorting during erythroid cell maturation as detected by immuno-gold labeling. During electron microscopy analysis we observed two distinct classes of erythroblastic islands. The islands varied in size and morphology, and the number and type of erythroid cells interacting with the central macrophage. Assessment of femoral marrow isolated from a cavid rodent species (guinea pig, Cavis porcellus) and a marsupial carnivore species (fat-tailed dunnarts, Sminthopsis crassicaudata) showed that while the morphology of the central macrophage varied, two different types of erythroblastic islands were consistently identifiable. Our findings suggest that these two classes of erythroblastic islands are conserved in mammalian evolution and may play distinct roles in red blood cell production.

  9. Association between Body Mass Index and Bone Mineral Density in Patients Referred for Dual-Energy X-Ray Absorptiometry Scan in Ajman, UAE.

    PubMed

    Fawzy, Tarek; Muttappallymyalil, Jayakumary; Sreedharan, Jayadevan; Ahmed, Amal; Alshamsi, Salma Obaid Saeed; Al Ali, Mariyam Saif Salim Humaid Bin Bader; Al Balsooshi, Khawla Ahmed

    2011-01-01

    Body Mass Index (BMI) is a good indicator for measurements of Bone Mineral Density (BMD) which measures the density of minerals present in the bones using a special scan. This study was conducted to assess the association between BMI and status of BMD among 101 individuals who underwent Dual-Energy X-ray Absorptiometry (DEXA) scan. 39 subjects had normal and 62 had low bone mineral density. BMD was low in 82.4% of people with normal BMI, 78.1% among overweight, and 44.2% among obese. There was a statistically significant association between these two variables (P < .001). Low BMD was recorded in 59.1% of females and 76.9% of males. Association between advancing age and lower BMI is an important risk factor in the occurrence of low BMD.

  10. Assessment of trabecular bone quality in human cadaver calcaneus using scanning confocal ultrasound and dual x-ray absorptiometry (DEXA) measurements

    NASA Astrophysics Data System (ADS)

    Qin, Yixian; Xia, Yi; Lin, Wei; Rubin, Clinton; Gruber, Barry

    2004-10-01

    Microgravity and aging induced bone loss is a critical skeleton complication, occurring particularly in the weight-supporting skeleton, which leads to osteoporosis and fracture. Advents in quantitative ultrasound (QUS) provide a unique method for evaluating bone strength and density. Using a newly developed scanning confocal acoustic diagnostic (SCAD) system, QUS assessment for bone quality in the real body region was evaluated. A total of 19 human cadaver calcanei, age 66 to 97 years old, were tested by both SCAD and nonscan mode. The scanning region covered an approximate 40×40 mm2 with 0.5 mm resolution. Broadband ultrasound attenuation (BUA, dB/MHz), energy attenuation (ATT, dB), and ultrasound velocity (UV, m/s) were measured. The QUS properties were then correlated to the bone mineral density (BMD) measured by DEXA. Correlations between BMD and QUS parameters were significantly improved by using SCAD as compared to nonscan mode, yielding correlations between BMD and SCAD QUS parameters as R=0.82 (BUA), and R=0.86 (est. BMD). It is suggested that SCAD is feasible for in vivo bone quality mapping. It can be potentially used for monitoring instant changes of bone strength and density. [Work supported by the National Space Biomedical Research Institute (TD00207), and New York Center for Biotechnology.

  11. Random field assessment of inhomogeneous bone mineral density from DXA scans can enhance the differentiation between postmenopausal women with and without hip fractures.

    PubMed

    Dong, Xuanliang Neil; Pinninti, Rajeshwar; Lowe, Timothy; Cussen, Patricia; Ballard, Joyce E; Di Paolo, David; Shirvaikar, Mukul

    2015-04-13

    Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogeneity, the BMD map in the hip region is considered as a random field and stochastic predictors can be calculated by fitting a theoretical model onto the experimental variogram of the BMD map. The objective of this study was to compare the ability of bone mineral density and stochastic assessment of inhomogeneous distribution of bone mineral density in predicting hip fractures for postmenopausal women. DXA scans in the hip region were obtained from postmenopausal women with hip fractures (N=47, Age: 71.3±11.4 years) and without hip fractures (N=45, Age: 66.7±11.4 years). Comparison of BMD measurements and stochastic predictors in assessing bone fragility was based on the area under the receiver operating characteristic curves (AUC) from logistic regression analyses. Although stochastic predictors offered higher accuracy (AUC=0.675) in predicting the risk of hip fractures than BMD measurements (AUC=0.625), this difference was not statistically significant (p=0.548). Nevertheless, the combination of stochastic predictors and BMD measurements had significantly (p=0.039) higher prediction accuracy (AUC=0.748) than BMD measurements alone. This study demonstrates that stochastic assessment of bone mineral distribution from DXA scans can serve as a valuable tool in enhancing the prediction of hip fractures for postmenopausal women in addition to BMD measurements.

  12. Predictive value of excretory urography, ultrasonography, computerized tomography, and liver and bone scan in the staging of bilharzial bladder cancer in Saudi Arabia

    SciTech Connect

    Hanash, K.A.; Bissada, N.K.; Abla, A.; Esmail, D.; Dowling, A.

    1984-07-01

    The role of ultrasonography, computed tomography (CT), and radioisotopic scanning in the staging of bilharzial bladder cancer has not been reported previously. Forty patients with invasive bladder cancer seen at the King Faisal Specialist Hospital and Research Centre between January 1978 and June 1981 underwent complete preoperative workup for staging of their tumors prior to radical cystectomy. The preoperative radiologic investigations included excretory urography (IVP), ultrasonography (US), CT of the pelvis, and liver and bone scans. The results of these investigations were compared with the operative and pathologic staging. Ninety-three percent of the patients with bilharzial cancer had evidence of ureteric obstruction on IVP compared with 22% of the nonbilharzial cancer patients. The presence of ureteric obstruction in these patients did not correlate with the stage of the disease with 83% of the patients with superficial tumors (T1 and T2) having hydroureteronephrosis. Ultrasonography and CT had an 83% accuracy in the staging of superficial tumors. Stage T3 tumors were understaged in 14% of the cases. Ultrasonography did not differentiate Stages T3 and T4 tumors while CT scan differentiated these two stages in 57% of the cases. Bone scan failed to reveal evidence of metastatic disease in any of the bilharzial cancer patients. Liver scan was suspicious for liver metastases in two patients with bilharzial cancers in whom open liver biopsy revealed only hepatic bilharziasis. Of all the radiographic studies, US or preferably CT scan seem to be of some value in the staging of bilharzial tumors localized to the bladder. Bone and liver scans are probably of no cost effective benefit.

  13. Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences

    PubMed Central

    Lundblad, Henrik; Maguire, Gerald Q.; Karlsson-Thur, Charlotte; Jonsson, Cathrine; Noz, Marilyn E.; Zeleznik, Michael P.; Jacobsson, Hans; Weidenhielm, Lars

    2015-01-01

    Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na18F− PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV) derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs) were drawn to include broken bone, other (normal) bone, and muscle. The SUVm(t) (m = max, mean) and a series of slopes were computed as (SUVm(ti) − SUVm(tj))/(ti − tj), for pairs of time values ti and tj. A Patlak-like analysis was performed for the same time values by computing ((VOIp(ti)/VOIe(ti))−(VOIp(tj)/VOIe(tj)))/(ti − tj), where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUVm slopes showed good agreement by both linear regression and correlation coefficient analysis (r = 84%, rs = 78%-SUVmax, r = 92%, and rs = 91%-SUVmean), suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min−1 or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of −0.06 min−1 usually indicated poor remodeling progress in this cohort. PMID:26436093

  14. Skeletal Scintigraphy (Bone Scan)

    MedlinePlus

    ... breastfeeding. Discuss whether you have recently taken a bismuth-containing medicine such as Pepto-Bismol or had ... inform the physician if you have taken a bismuth-containing medicine like Pepto-Bismol or if you ...

  15. Skeletal Scintigraphy (Bone Scan)

    MedlinePlus

    ... and medications you’re taking, including vitamins and herbal supplements. Your doctor will instruct you on how to ... any medications you are taking, including vitamins and herbal supplements and if you have allergies, have recently been ...

  16. Radionuclide bone imaging and densitometry

    SciTech Connect

    Mettler, F.A.

    1988-01-01

    This book contains 13 selections. Some of the titles are: Radionuclides and the Normal Bone Scan; The Radionuclide Bone Scan in Malignant Disease; Pediatric Applications of Radionuclide Bone Imaging; The Radionuclide Bone Scan in Arthritis and Metabolic and Miscellaneous Disorders; and Soft Tissue Activity on the Radionuclide Bone Scan.

  17. [Linear scanning analysis of prehistoric human bones in Xigongqiao Site, Tengzhou, Shandong Province by use of SEM-EDS].

    PubMed

    Hu, Yao-wu; He, De-liang; Dong, Yu; Wang, Chang-sui; Gao, Ming-kui; Lan, Yu-fu

    2006-06-01

    Ancient human bones in Xigongqiao Site, Tengzhou, Shandong Province, were analyzed by use of SEM-EDS. SEM indicated that the microstructure of Haversian system was destroyed under the impact of bone diagenesis. The apparent difference in elemental distribution in the bone cross section showed that the enrichment or loss of elements can occur not only in the inner and outer surface, but also in the middle. This study will have great influence on how to deal with the ancient human bones before any palaeodietary research in the future.

  18. Bone natural autofluorescence and confocal laser scanning microscopy: Preliminary results of a novel useful tool to distinguish between forensic and ancient human skeletal remains.

    PubMed

    Capasso, Luigi; D'Anastasio, Ruggero; Guarnieri, Simone; Viciano, Joan; Mariggiò, Maria

    2017-03-01

    The fast, high-throughput distinction between palaeoanthropological/archaeological remains and recent forensic/clinical bone samples is of vital importance in the field of medico-legal science. In this paper, a novel dating method was developed using the autofluorescence of human bones and the confocal laser scanning microscope as the means to distinguish between archaeological and forensic anthropological skeletal findings. Human bones exhibit fluorescence, typically induced by natural antibiotics that are absorbed by collagen, and provide secondary, exogenous fluorophores. However, primary natural fluorescence (or autofluorescence) caused by enigmatic endogenous fluorophores is also present as a micro-phenomenon, whose nature is still obscure. Here, we show that the endogenous fluorophores are mucopolysaccharides of the Rouget-Neumann sheath and, more relevant, that the intensity of the natural fluorescence in human bone decreases in a relationship to the antiquity of the samples. These results suggest that the autofluorescence of bone is a promising technique for the assessment of skeletal remains that may be potentially of medico-legal interest. A larger study is proposed to confirm these findings and to create a predictive model between the autofluorescence intensity and the time since death.

  19. Prostatic specific antigen and bone scan in the diagnosis and follow-up of prostate cancer. Can diagnostic significance of PSA be increased?

    PubMed

    Bantis, Athanasios; Grammaticos, Philip

    2012-01-01

    Prostate cancer (PC) is currently the most frequently diagnosed cancer in males and constitutes a major health issue in developed countries. On the other hand, the majority of PC cases are considered clinically not significant and certainly not lethal. These discrepancies highlight the need for the early detection of especially those cases that have aggressive features and call for early and radical intervention. The clinical use of prostatic specific antigen (PSA) towards this end is recognized as inadequate since PSA is prostate specific, but not a PC specific marker, as it is known to increase in other prostate diseases such as benign hyperplasia, inflammations, transrectal ultrasound examination, biopsy and after transurethral prostatectomy. However due to lack of other more specific markers, digital rectal examination combined with serum PSA are suggested for PC screening and diagnosis. With regard to advanced disease where bone involvement is the rule, nuclear medicine bone scan using radioactive bisphosphonates such as technetium-99m methylene-diphosphonate is quite common and reliable technique for detecting and monitoring bone metastases. The major advantage of nuclear scintigraphy is its ability to reveal bone metastases significantly earlier than the conventional X-ray imaging techniques. PSA density, velocity, doubling time and free to total PSA ratio increase the significance of serum PSA in diagnosing PC. The combination of an increased PSA (>20ng/mL) and a high biopsy Gleason score (>8) enhances the possibility of bone metastases (P<0001) and mandates a bone scan. In conclusion, serum PSA testing is currently recommended in symptomatic PC patients for disease staging and treatment monitoring and in asymptomatic selected population groups aged more than 50 years. It is reasonable to suggest that PSA density, velocity, doubling time and free to total PSA ratio or combining PSA with Gleason score shall greatly increase PSA specificity in detecting PC

  20. Bisphosphonate-related osteonecrosis of jaws in advanced stage breast cancer was detected from bone scan: a case report

    PubMed Central

    Chirappapha, Prakasit; Thongjood, Thanaporn; Aroonroch, Rangsima

    2017-01-01

    Bisphosphonates (BPs) are indicated to treat skeletal-related events (SREs) for cancer patients with bone metastasis. We report a 79-year-old woman with advanced stage breast cancer with bone metastasis who was prescribed BPs (zoledronate), then developed osteonecrosis of jaw. We provide a brief review of the pathogenesis, diagnosis and treatment of this complication. PMID:28210558

  1. Using PET/CT Bone Scan Dynamic Data to Evaluate Tibia Remodeling When a Taylor Spatial Frame Is Used: Short and Longer Term Differences.

    PubMed

    Lundblad, Henrik; Maguire, Gerald Q; Karlsson-Thur, Charlotte; Jonsson, Cathrine; Noz, Marilyn E; Zeleznik, Michael P; Jacobsson, Hans; Weidenhielm, Lars

    2015-01-01

    Eighteen consecutive patients, treated with a Taylor Spatial Frame for complex tibia conditions, gave their informed consent to undergo Na(18)F(-) PET/CT bone scans. We present a Patlak-like analysis utilizing an approximated blood time-activity curve eliminating the need for blood aliquots. Additionally, standardized uptake values (SUV) derived from dynamic acquisitions were compared to this Patlak-like approach. Spherical volumes of interest (VOIs) were drawn to include broken bone, other (normal) bone, and muscle. The SUV m (t) (m = max, mean) and a series of slopes were computed as (SUV m (t i ) - SUV m (t j ))/(t i - t j ), for pairs of time values t i and t j . A Patlak-like analysis was performed for the same time values by computing ((VOI p (t i )/VOI e (t i ))-(VOI p (t j )/VOI e (t j )))/(t i - t j ), where p = broken bone, other bone, and muscle and e = expected activity in a VOI. Paired comparisons between Patlak-like and SUV m slopes showed good agreement by both linear regression and correlation coefficient analysis (r = 84%, r s = 78%-SUVmax, r = 92%, and r s = 91%-SUVmean), suggesting static scans could substitute for dynamic studies. Patlak-like slope differences of 0.1 min(-1) or greater between examinations and SUVmax differences of ~5 usually indicated good remodeling progress, while negative Patlak-like slope differences of -0.06 min(-1) usually indicated poor remodeling progress in this cohort.

  2. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    SciTech Connect

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J. )

    1989-08-01

    Although few reports address the use of three-phase bone scanning (TPBS) and {sup 111}In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.

  3. Hypothyroidism in McCune-Albright Syndrome and Role of Bone Scan in Management of Fibrous Dysplasia: An Unusual Case Scenario with Review of Literature.

    PubMed

    Kumar, Narvesh; Kheruka, Subhash Chand; Singh, Rani Kunti R; Ravina, Mudalsha; Dutta, Deepanksha; Gambhir, Sanjay

    2017-01-01

    The McCune-Albright syndrome (MAS) is a triad of café-au-lait skin pigmentation, precocious puberty (PP), and polyostotic fibrous dysplasia of bone (FD). In general, FD seems to be the most common component of MAS but very rarely precocious puberty can be found in association with café-au-lait skin pigmentation in the absence of FD (about 1% of the cases). Therefore, a more clinically relevant definition of MAS is fibrous dysplasia of bone (FD) and at least one of the typical hyperfunctioning endocrinopathy and/or café-au-lait spots, with almost any combination possible. Bone scan can be the modality of choice to look for bone disease burden of fibrous dysplasia in most patients of MAS and may change the management accordingly. Most of the cases of MAS reported worldwide are associated with hyperthyroidism, up to best of our knowledge on the basis of literature search in pubmed and Google; no case was reported with hypothyroidism. Herein, we report a 12-year-old girl diagnosed with MAS and associated hypothyroidism. We have also reviewed the MAS related literature.

  4. Hypothyroidism in McCune–Albright Syndrome and Role of Bone Scan in Management of Fibrous Dysplasia: An Unusual Case Scenario with Review of Literature

    PubMed Central

    Kumar, Narvesh; Kheruka, Subhash Chand; Singh, Rani Kunti R.; Ravina, Mudalsha; Dutta, Deepanksha; Gambhir, Sanjay

    2017-01-01

    The McCune–Albright syndrome (MAS) is a triad of café-au-lait skin pigmentation, precocious puberty (PP), and polyostotic fibrous dysplasia of bone (FD). In general, FD seems to be the most common component of MAS but very rarely precocious puberty can be found in association with café-au-lait skin pigmentation in the absence of FD (about 1% of the cases). Therefore, a more clinically relevant definition of MAS is fibrous dysplasia of bone (FD) and at least one of the typical hyperfunctioning endocrinopathy and/or café-au-lait spots, with almost any combination possible. Bone scan can be the modality of choice to look for bone disease burden of fibrous dysplasia in most patients of MAS and may change the management accordingly. Most of the cases of MAS reported worldwide are associated with hyperthyroidism, up to best of our knowledge on the basis of literature search in pubmed and Google; no case was reported with hypothyroidism. Herein, we report a 12-year-old girl diagnosed with MAS and associated hypothyroidism. We have also reviewed the MAS related literature. PMID:28242980

  5. Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs.

    PubMed

    Brzobohatá, Hana; Prokop, Josef; Horák, Martin; Jancárek, Alexandr; Velemínská, Jana

    2012-09-01

    The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.

  6. EFFECTS OF CHEMICAL PROCESSING AND OXIDE ETHYLENE STERILIZATION ON CORTICAL AND CANCELLOUS RAT BONE: A LIGHT AND ELECTRON SCANNING MICROSCOPY STUDY

    PubMed Central

    Castiglia, Marcello Teixeira; da Silva, Juliano Voltarelli F.; Frezarim Thomazini, José Armendir; Volpon, José Batista

    2015-01-01

    To evaluate, under microscopic examination, the structural changes displayed by the trabecular and cortical bones after being processed chemically and sterilized by ethylene oxide. Methods: Samples of cancellous and cortical bones obtained from young female albinus rats (Wistar) were assigned to four groups according to the type of treatment: Group I- drying; Group II- drying and ethylene oxide sterilization; III- chemical treatment; IV- chemical treatment and ethylene oxide sterilization. Half of this material was analyzed under ordinary light microscope and the other half using scanning electron microscopy. Results: In all the samples, regardless the group, there was good preservation of the general morphology. For samples submitted to the chemical processing there was better preservation of the cellular content, whereas there was amalgamation of the fibres when ethylene oxide was used. Conclusion: Treatment with ethylene oxide caused amalgamation of the fibers, possibly because of heating and the chemical treatment contributed to a better cellular preservation of the osseous structure. PMID:26998450

  7. Imaging Non-Specific Wrist Pain: Interobserver Agreement and Diagnostic Accuracy of SPECT/CT, MRI, CT, Bone Scan and Plain Radiographs

    PubMed Central

    Huellner, Martin W.; Bürkert, Alexander; Strobel, Klaus; Pérez Lago, María del Sol; Werner, Lennart; Hug, Urs; von Wartburg, Urs; Seifert, Burkhardt; Veit-Haibach, Patrick

    2013-01-01

    Purpose Chronic hand and wrist pain is a common clinical issue for orthopaedic surgeons and rheumatologists. The purpose of this study was 1. To analyze the interobserver agreement of SPECT/CT, MRI, CT, bone scan and plain radiographs in patients with non-specific pain of the hand and wrist, and 2. to assess the diagnostic accuracy of these imaging methods in this selected patient population. Materials and Methods Thirty-two consecutive patients with non-specific pain of the hand or wrist were evaluated retrospectively. All patients had been imaged by plain radiographs, planar early-phase imaging (bone scan), late-phase imaging (SPECT/CT including bone scan and CT), and MRI. Two experienced and two inexperienced readers analyzed the images with a standardized read-out protocol. Reading criteria were lesion detection and localisation, type and etiology of the underlying pathology. Diagnostic accuracy and interobserver agreement were determined for all readers and imaging modalities. Results The most accurate modality for experienced readers was SPECT/CT (accuracy 77%), followed by MRI (56%). The best performing, though little accurate modality for inexperienced readers was also SPECT/CT (44%), followed by MRI and bone scan (38% each). The interobserver agreement of experienced readers was generally high in SPECT/CT concerning lesion detection (kappa 0.93, MRI 0.72), localisation (kappa 0.91, MRI 0.75) and etiology (kappa 0.85, MRI 0.74), while MRI yielded better results on typification of lesions (kappa 0.75, SPECT/CT 0.69). There was poor agreement between experienced and inexperienced readers in SPECT/CT and MRI. Conclusions SPECT/CT proved to be the most helpful imaging modality in patients with non-specific wrist pain. The method was found reliable, providing high interobserver agreement, being outperformed by MRI only concerning the typification of lesions. We believe it is beneficial to integrate SPECT/CT into the diagnostic imaging algorithm of chronic wrist

  8. Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

    SciTech Connect

    Tselikas, Lambros Joskin, Julien; Roquet, Florian; Farouil, Geoffroy; Dreuil, Serge; Hakimé, Antoine Teriitehau, Christophe; Auperin, Anne; Baere, Thierry de Deschamps, Frederic

    2015-02-15

    PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.

  9. Comparison of Accuracy in Calculation of Absorbed Dose to Patients Following Bone Scan with 99mTc-Marked Diphosphonates by Two Different Background Correction Methods

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Damoori, Mehri; Tavakoli, Mohammad Bagher; Moslehi, Masoud

    2016-01-01

    To improve the accuracy of the activity quantification and the image quality in scintigraphy, scatter correction is a vital procedure. The aim of this study is to compare the accuracy in calculation of absorbed dose to patients following bone scan with 99mTc-marked diphosphonates (99mTc-MDP) by two different methods of background correction in conjugate view method. This study involved 22 patients referring to the Nuclear Medicine Center of Shahid Chamran Hospital, Isfahan, Iran. After the injection of 99mTc-MDP, whole-body images from patients were acquired at 10, 60, 90, and 180 min. Organ activities were calculated using the conjugate view method by Buijs and conventional background correction. Finally, the absorbed dose was calculated using the Medical Internal Radiation Dosimetry (MIRD) technique. The results of this study showed that the absorbed dose per unit of injected activity (rad/mCi) ± standard deviation for pelvis bone, bladder, and kidneys by Buijs method was 0.19 ± 0.05, 0.08 ± 0.01, and 0.03 ± 0.01 and by conventional method was 0.13 ± 0.04, 0.08 ± 0.01, and 0.024 ± 0.01, respectively. This showed that Buijs background correction method had a high accuracy compared to conventional method for the estimated absorbed dose of bone and kidneys whereas, for the bladder, its accuracy was low. PMID:27014610

  10. Menopause and Bone Loss

    MedlinePlus

    ... You reach your highest bone mass (size and density) at about age 30. Then, sometime between age ... your bones, your doctor may do a bone density test (DEXA scan). This test gives exact measurements ...

  11. Scanning electron microscopy of collagen fiber orientation in the bone lamellar system in non-decalcified human samples.

    PubMed

    Pannarale, L; Braidotti, P; d'Alba, L; Gaudio, E

    1994-01-01

    Previous studies on collagen fiber orientation have led to different interpretations and theories about the fiber arrangement in the lamellar compact bone. The purpose of this investigation was to provide new and more in-depth data on fiber arrangement in the lamellar bone system in order to explain the orientation of the fiber bundles. This was carried out by applying a simple method of preparation which permitted observation of non-decalcified samples. A previously isolated Haversian system was subjected to slow bending up to reaching the fracture point. Hence, the fracture surface was observed by SEM. The same samples were also observed by polarized light microscopy. A significant alternation of fiber orientation in the adjacent lamellae was observed. Different domains of differently oriented fibers were present within the same lamella; conjugating fibers connecting adjacent lamellae were also shown. This method avoided most of the artifacts due to chemical treatment of bone samples. The results can be easily interpreted by means of the same criteria applied in mechanics for the studying of composite materials.

  12. A comparison of 111In with 52Fe and 99mTc-sulfur colloid for bone marrow scanning.

    PubMed

    Merrick, M V; Gordon-Smith, E C; Lavender, J P; Szur, L

    1975-01-01

    Under most circumstances 52Fe, 111In, and colloid show a similar distribution of marrow. The lesser uptake of 111In by liver and spleen may occasionally be of value in permitting visualization of that portion of the spinal marrow obscured by these organs in the colloid scan. However, in red cell aplasia, when there is dissociation between phagocytic and erythropoietic functions, scanning with 111In gives no information about erythropoietic tissue distribution. Therefore, indium cannot be used as an analog for iron in the study of the hematopoietic system.

  13. Radionucleotide scanning in osteomyelitis

    SciTech Connect

    Sachs, W.; Kanat, I.O.

    1986-07-01

    Radionucleotide bone scanning can be an excellent adjunct to the standard radiograph and clinical findings in the diagnosis of osteomyelitis. Bone scans have the ability to detect osteomyelitis far in advance of the standard radiograph. The sequential use of technetium and gallium has been useful in differentiating cellulitis and osteomyelitis. Serial scanning with technetium and gallium may be used to monitor the response of osteomyelitis to antibiotic therapy.

  14. Gallium scintigraphy in bone infarction. Correlation with bone imaging

    SciTech Connect

    Armas, R.R.; Goldsmith, S.J.

    1984-01-01

    The appearance of gallium-67 images in bone infarction was studied in nine patients with sickle cell disease and correlated with the bone scan findings. Gallium uptake in acute infarction was decreased or absent with a variable bone scan uptake, and normal in healing infarcts, which showed increased uptake on bone scan. The significance of these findings is discussed.

  15. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    SciTech Connect

    Caiazza, S.; Falcinelli, G.; Pintucci, S. )

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized.

  16. Comparative evaluation of the efficacy of synthetic nanocrystalline hydroxyapatite bone graft (Ostim®) and synthetic microcrystalline hydroxyapatite bone graft (Osteogen®) in the treatment of human periodontal intrabony defects: A clinical and denta scan study

    PubMed Central

    Kamboj, Monika; Arora, Ruchika; Gupta, Harinder

    2016-01-01

    Background: To evaluate the relative efficacy of synthetic nanocrystalline hydroxyapatite (HA) (Ostim®) and microcrystalline HA (Osteogen®) bone grafts in the treatment of human periodontal intrabony defects clinically and radiographically through denta scan. Materials and Methods: Ten chronic periodontitis patients with bilateral intrabony periodontal defects of ≥2 mm radiographic defect depth below 55 years of age were selected randomly and treated with synthetic nanocrystalline HA (Ostim®) or synthetic microcrystalline HA (Osteogen®) bone graft. Clinical parameters including probing depth (PD) and clinical attachment level (CAL) were measured preoperatively and postoperatively at 3 and 6 months for each of the defects using an occlusal acrylic stent. Radiographic parameters were measured with the help of denta scan preoperatively and postoperatively at 6 months. Results: At 6 months following therapy, the Osteogen® group showed a reduction in mean PD from 11.10 ± 1.663 to 8.50 ± 0.850 mm and a change in mean CAL from 6.30 ± 1.160 to 3.40 ± 0.516 mm, whereas in the Ostim® group, the mean PD decreased from 11.20 ± 0.919 to 8.30 ± 0.823 mm and mean CAL decreased from 6.10 ± 0.738 to 3.30 ± 0.483 mm. At 6 months following therapy, denta scan showed a reduction in mean intrabony defect depth in the Osteogen® group from 2.54 ± 0.786 to 1.01 ± 0.448 mm, whereas in the Ostim® group, it was 2.71 ± 0.650 mm to 1.12 ± 0.563 mm. Conclusion: It was concluded that both the HA bone grafts produced statistically significant reduction in pocket depth, in the depth of osseous lesion, and a statistically significant gain in attachment level, irrespective of their physico-chemical properties. PMID:28298825

  17. The effect of a cartilage bone marrow extract on experimentally induced osteoarthrosis in the knee joints of rabbits. A scanning electron microscopic study.

    PubMed

    Neumüller, J; Partsch, G; Adamiker, D; Eberl, R

    1981-03-01

    The development of osteoarthrosis following a partial meniscectomy on the knee cartilage of rabbits (Chinchilla hybrids) was monitored with a scanning electron microscope. Simultaneously, a study was made of the effect of the cartilage bone marrow extract Rumalon trademark on the development of the osteoarthrotic changes. Twelve days after the operation, osteoarthrotic changes were evident in the untreated operated joints. After 36 days the damage caused to the cartilage was already radical. The immobility of the operated joint also gave rise to obvious changes in the cartilage of the knee joints which had not undergone an operation. The irregular weight distribution due to the fixation of one joint was apparently enough to provoke degenerative processes on the other side. When the cartilage bone marrow extract Rumalon trademark was administered three times weekly (0.5 mg/kg body weight i.m.) a distinct retardation of the osteoarthrotic development in the early stages was observed. Where the changes had penetrated to the inner cartilage layers, no difference could be established compared to the untreated animals.

  18. Unexplained high BMD in DXA-scanned patients is generalized throughout the skeleton and characterized by thicker cortical and trabecular bone.

    PubMed

    Lomholt, S; Amstrup, A K; Moser, E; Jakobsen, N F B; Mosekilde, L; Vestergaard, P; Rejnmark, L

    2015-04-01

    Unexplained high bone mineral density (BMD) is a rare condition and the mechanisms responsible are yet to be described in detail. The aim of the study was to identify patients with unexplained high BMD from a local DXA database and compare their radiological phenotype with an age- and a gender-matched group of population-based controls. We defined high BMD as a DXA Z-score ≥ + 2.5 at the total hip and lumbar spine. We characterized the findings as "unexplained" if no osteodegenerative changes, bone metabolic disease, or arthritis at the hip or lumbar spine was observed. All participants were investigated with high-resolution peripheral quantitative computed tomography (HR-pQCT), QCT, DXA, fasting blood samples, a 24-h urine sample, and questionnaires. The DXA database contained data on 25,118 patients. Initially, 138 (0.55%) potential participants with high BMD were identified, and during the study ten additional cases were identified from new DXA scans. Sixty-seven patients accepted to participate in the study, and among these we identified 15 women and one man with unexplained high BMD. These 15 women had higher BMD throughout the skeleton relative to controls, similar area/volume at the hip and the distal extremities, a higher number of trabeculae, which was thicker than in the controls, and a higher finite element estimated bone strength. The 15 women were heavier and had a higher fat mass then controls. We conclude that patients with unexplained high BMD have a generalized high BMD phenotype throughout their skeleton, which is characterized with a denser microarchitecture.

  19. Exposure of veterinary personnel to ionising radiation during bone scanning of horses by nuclear scintigraphy with 99mtechnetium methylene diphosphonate.

    PubMed

    Gatherer, M E; Faulkner, J; Voûte, L C

    2007-06-16

    The aim of this study was to compare the radiation doses received by the personnel drawing up and injecting the radiopharmaceutical and operating the nuclear scintigraphy equipment, and those restraining nine horses while they were being scanned during scintigraphic investigations of lameness. Sensitive electronic dosimeters were worn by the personnel and the doses they received during the administration of the radiopharmaceutical and during the period of image acquisition were recorded at intervals. On average, 90 per cent of the total doses were received during the period of image acquisition. There was no significant difference between the total dose received by the person who drew up and injected the radiopharmaceutical, and the person restraining the horse during its administration. However, the person holding the horse received approximately twice the dose received by the person operating the equipment during the period of image acquisition.

  20. Personalized estimation of dose to red bone marrow and the associated leukaemia risk attributable to pelvic kilo-voltage cone beam computed tomography scans in image-guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Zhang, Yibao; Yan, Yulong; Nath, Ravinder; Bao, Shanglian; Deng, Jun

    2012-07-01

    The aim of this study is to investigate the imaging dose to red bone marrow (RBM) and the associated leukaemia risks attributable to pelvic kilo-voltage cone beam computed tomography (kVCBCT) scans in image-guided radiation therapy (IGRT). The RBM doses of 42 patients (age 2.7-86.4 years) were calculated using Monte Carlo simulations. The trabecular spongiosa was segmented to substitute RBM rather than the whole bone. Quantitative correlations between anthropometric variables such as age, physical bone density (PBD) and RBM dose were established. Personalized leukaemia risk was evaluated using an improved Boice model which included the age-associated RBM involvement. An incremental leukaemia risk of 29%-82% (mean = 45%) was found to be associated with 40 pelvic kVCBCT scans in the subject group used in a typical external beam radiation therapy course. Higher risks were observed in children. Due to the enhanced photoelectric effect in high atomic number materials, PBD was observed to strongly affect the RBM dose. Considerable overestimations (9%-42%, mean = 28%) were observed if the whole bone doses were used as surrogates of RBM doses. The personalized estimation of RBM dose and associated leukaemia risk caused by pelvic kVCBCT scans is clinically feasible with the proposed empirical models. Higher radiogenic cancer risks are associated with repeated kVCBCT scans in IGRT of cancer patients, especially children.

  1. Instrumentation for bone density measurement

    NASA Technical Reports Server (NTRS)

    Meharg, L. S.

    1968-01-01

    Measurement system evaluates the integrated bone density over a specific cross section of bone. A digital computer converts stored bone scan data to equivalent aluminum calibration wedge thickness, and bone density is then integrated along the scan by using the trapezoidal approximation integration formula.

  2. TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

    SciTech Connect

    Perk, T; Bradshaw, T; Muzahir, S; Jeraj, R; Meyer, E

    2014-06-15

    Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate

  3. [Diagnostic value of MRI versus 99Tcm-MDP bone scan in osseous metastasis of prostate cancer: a meta-analysis].

    PubMed

    Shen, Guohua; Zhou, Luyi; Jia, Zhiyun; Zhang, Wenjie; Wang, Qiao; Deng, Houfu

    2014-08-01

    This paper is aimed to assess the diagnostic value of MRI versus 99 Tcm-methylene diphosphonate (99 Tcm- MDP) bone scan (BS) for osseous metastases in patients with prostate cancer. The computer-based retrieval was conducted on PubMed, EMBASE, EBSCO, Web of Knowledge, the Cochrane Library and Ovid data bases to search for trials about diagnosing osseous metastases of prostate cancer with MRI and 99Tc"m-MDP BS. Selected with time acceptance and time exclusion criteria, the data quality were evaluated with QUADAS quality assessment tool and collected. We used the Meta-Disc software to conduct meta-analysis, and then calculated the pooled sensitivity, specificity and diagnostic odds ratio (DOR), drew the summary receiving operating characteristic (SROC) curve, and measured the area under curve (AUC) and Q value. Then five studies were included, involving 353 patients. The pooled sensitivity of MRI and BS was 0. 95 (95% CI 0. 90~0. 98) and 0. 67 (95% CI 0. 58~0. 75), respectively. The pooled specificity was 0. 97 (95% CI 0. 94~0. 99) and 0. 88 (95% CI 0. 83~0. 91), respectively. The pooled DOR was 402.99 (95% CI 119. 05 ~1364. 15) and 23. 85 (95% CI 1. 32~431. 48), respectively. The AUC was 0. 990 1 and 0. 624 1, respectively. The Q was 0. 958 7 and 0. 593 8. It can well be concluded that MRI is more effective than 99 Tcm-MDP BS in the diagnosis of osseous metastases in patients with prostate cancer.

  4. Bone mineral density test

    MedlinePlus

    ... density test; Bone densitometry; DEXA scan; DXA; Dual-energy x-ray absorptiometry; p-DEXA; Osteoporosis-BMD ... most common and accurate way uses a dual-energy x-ray absorptiometry (DEXA) scan. DEXA uses low- ...

  5. Scanning electron microscopy study of new bone formation following small and large defects preserved with xenografts supplemented with pamidronate-A pilot study in Fox-Hound dogs at 4 and 8 weeks.

    PubMed

    Lozano-Carrascal, Naroa; Satorres-Nieto, Marta; Delgado-Ruiz, Rafael; Maté-Sánchez de Val, José Eduardo; Gehrke, Sergio Alexandre; Gargallo-Albiol, Jorge; Calvo-Guirado, José Luis

    2017-01-01

    The aim of the present study was to evaluate the feasibility of SEM and EDX microanalysis on evaluating the effect of porcine xenografts (MP3(®)) supplemented with pamidronate during socket healing. Mandibular second premolars (P2) and first molars (M1) were extracted from six Beagle dogs. P2 were categorized as small defects (SD) and M1 as large defects (LD). Four random groups were created: SC (small control defects with MP3(®)), ST (small test defects MP3(®)+pamidronate), LC (large control defects with MP3(®)), and LT (large test defects MP3(®)+pamidronate). At four and eight weeks of healing the samples were evaluated fisically through scanning electron microscopy (SEM), and chemical element mapping was carried out by Energy dispersive X-ray spectroscopy (EDX). After four weeks of healing, SEM and EDX analysis revealed more mineralized bone in ST and LT groups compared with control groups (p<0.05). After eight weeks, Ca/P ratios were slightly higher for small defects (groups SC and ST); in SEM description, in both control and test groups, trabecular bone density was similar to the adjacent mineralized cortical bone. Within the limitations of this experimental study, SEM description and EDX elemental microanalysis have demonstrated to be useful techniques to assess bone remodelling of small and large defects. Both techniques show increased bone formation in test groups (MP3(®) modified with pamidronate) after four and eight weeks of healing.

  6. Growth Arrest Line Mimicking Lymphoma Involvement: The Findings of (99m)Tc-MDP Bone SPECT/CT and Serial Bone Scan in a Child with Non-Hodgkin's Lymphoma.

    PubMed

    Kim, Chanwoo; Kim, Ji Young; Choi, Yun Young; Lee, Seunghun; Lee, Young-Ho

    2016-06-01

    Growth arrest lines appear as dense sclerotic lines parallel to the growth plate of long bones on radiography. We describe the case of a 9-year-old female with growth arrest lines initially masquerading as lymphoma involvement on (99m)Tc-MDP bone scintigraphy who had been treated with chemotherapy for non-Hodgkin's lymphoma about 3 years previously. Subsequent regional bone SPECT/CT clearly diagnosed the growth arrest lines, and retrograde review of previous bone scintigraphy demonstrated line migration in this patient. Growth arrest lines should be considered a possible diagnosis on bone scintigraphy, especially in the surveillance of children who have experienced severe childhood infections, malnutrition, immobilization, or treatment with immunosuppressive or chemotherapeutic drugs that may inhibit bone growth.

  7. Bone densitometry.

    PubMed

    Chun, Kwang J

    2011-05-01

    Conventional radiographic methods allow physicians to visualize bone structure. However, they do not offer information on the bone mineral density (BMD), which can facilitate early diagnosis and treatment of osteoporosis. Bone densitometry, by contrast, helps to detect bone mineral loss at an early stage because it provides accurate quantitative measurement of BMD. With an emphasis on quantification, shorter scanning time and precision, scientists have been developing BMD measurement devices that use absorption technique. They first developed single-energy absorptiometry (single-photon absorptiometry) by using I-125, which could measure BMD of peripheral bones. Single-photon absorptiometry was replaced by dual-energy absorptiometry (dual photon absorptiometry [DPA]) that used gadolinium-153. DPA had greater accuracy in measuring the BMD of central skeletal bones. Single-energy x-ray absorptiometry was also developed but it had limitations in measuring central skeletal BMD. In the mid-1980s, dual-energy x-ray absorptiometry (DXA) was introduced and widely accepted for the early detection, treatment, and follow-up study of osteoporosis. There are several reasons for the popularity. DXA can measure BMD of posteroanterior spine and hip in a much shorter time than DPA while being capable of measuring BMD of peripheral bones. Other advantages include very low radiation doses to the patients, high image resolution, precision, and stable calibration of the instruments. In recent years, DXA has also been applied to lateral spine for the density of trabecular bone, to the whole body for the measurement of total body bone density and for the body composition, and to the spine for the vertebral fracture assessment. Still, posteroanterior spine and hip scans remain the most common applications of DXA because data on the normal range of BMD of the skeletal sites for different age, sex, and ethnic groups are compiled and made available with the devices, which gives the physician

  8. Bone graft

    MedlinePlus

    Autograft - bone; Allograft - bone; Fracture - bone graft; Surgery - bone graft; Autologous bone graft ... Fuse joints to prevent movement Repair broken bones (fractures) that have bone loss Repair injured bone that ...

  9. [Ultrasound scanning of the distraction regenerate in case of multilocus elongation of the fragments in patients with defects of long bones].

    PubMed

    Menshikova, T I; Borzunov, D Iu; Dolganova, T I

    2014-01-01

    It was done ultrasound examination of distraction regenerates in patients with defect of bone tissue. The first group included 4 patients who had the size of congenital bone tissue defect 15.8±8.1 cm; the second group (3 patients) included posttraumatic defects with defect size 11.75±3.6 cm; the third group (4 patients) included posttraumatic defects with defect size 11±5.3 cm. It was discovered the particularities of distraction regenerate structural condition in case of low level of reparative osteogenesis. In the first group "ischemic" regenerate was characterized by slow formation of bone trabecules. In the second group "ischemic" regenerate had one or two hypo-echogenic cystic-like formations in the intermediate regenerate area. All patients of the third group had organotypic remodeling of the regenerate according to terms of distraction and fixation.

  10. Paget disease of the bone

    MedlinePlus

    ... that may indicate Paget disease include: Bone scan Bone x-ray Elevated markers of bone breakdown (for example, N-telopeptide) This disease may ... of Paget disease. Alternative Names Osteitis deformans Images ... X-ray References Ralston SH. Paget disease of bone. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  11. Data Feature Extraction for High-Rate 3-Phase Data

    SciTech Connect

    2016-10-18

    This algorithm processes high-rate 3-phase signals to identify the start time of each signal and estimate its envelope as data features. The start time and magnitude of each signal during the steady state is also extracted. The features can be used to detect abnormal signals. This algorithm is developed to analyze Exxeno's 3-phase voltage and current data recorded from refrigeration systems to detect device failure or degradation.

  12. How Is Bone Cancer Diagnosed?

    MedlinePlus

    ... solid. The cancer can also appear as a hole in the bone. Sometimes doctors can see a ... the bone scan image as dense, gray to black areas, called “hot spots.” These areas suggest metastatic ...

  13. Bone Cancer - Multiple Languages: MedlinePlus

    MedlinePlus

    ... Bone Scan (Arabic) العربية Bilingual PDF Health Information Translations Chinese - Simplified (简体中文) Bone Scan 骨扫描 - 简体中文 (Chinese - Simplified) Bilingual PDF Health Information Translations Chinese - Traditional (繁體中文) Bone Scan 骨骼掃描 - 繁體中文 (Chinese - ...

  14. Nuclear Scans

    MedlinePlus

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  15. WBC scan

    MedlinePlus

    ... in the body. It is a type of nuclear scan . How the Test is Performed Blood will ... radiation. Due to the slight radiation exposure, most nuclear scans (including WBC scan) are not recommended for ...

  16. Liver scan

    MedlinePlus

    ... Nuclear scan - technetium; Nuclear scan - liver or spleen Images Liver scan References Lidofsky S. Jaundice. In: Feldman M, ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  17. PET scan

    MedlinePlus

    ... may have an allergic reaction to the tracer material. Some people have pain, redness, or swelling at ... with diabetes. Most PET scans are now performed along with a CT scan. This combination scan ...

  18. Bone tumor

    MedlinePlus

    Tumor - bone; Bone cancer; Primary bone tumor; Secondary bone tumor; Bone tumor - benign ... The cause of bone tumors is unknown. They often occur in areas of the bone that grow rapidly. Possible causes include: Genetic defects ...

  19. Preoperative nuclear scans in patients with melanoma

    SciTech Connect

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-05-15

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive.

  20. Radioimmune imaging of bone marrow in patients with suspected bone metastases from primary breast cancer

    SciTech Connect

    Duncker, C.M.; Carrio, I.; Berna, L.; Estorch, M.; Alonso, C.; Ojeda, B.; Blanco, R.; Germa, J.R.; Ortega, V. )

    1990-09-01

    Radioimmune imaging of bone marrow was performed by technetium-99m- (99mTc) labeled antigranulocyte monoclonal antibody BW 250/183 (AGMoAb) scans in 32 patients with suspected bone metastases from primary breast cancer. AGMoAb scans showed bone marrow defects in 25/32 (78%) patients; bone invasion was subsequently confirmed in 23 (72%) patients. Conventional bone scans performed within the same week detected bone metastases in 17/32 (53%) patients (p less than 0.001). AGMoAb scans detected more sites indicating metastatic disease than bone scans in 12 of these 17 patients (71%). All patients with bone metastases in the axial skeleton had bone marrow defects at least at the sites of bone metastases. Of 15 patients with normal, or indicative of, benign disease bone scans, 8 patients (53%) presented with bone marrow defects in the AGMoAb scans. Bone invasion was confirmed in six of them. AGMoAb bone marrow scans provide a method for the early detection of bone metastatic invasion in patients with breast cancer and suspected bone metastases.

  1. Bone x-ray

    MedlinePlus

    ... not being scanned. Alternative Names X-ray - bone Images Skeleton Skeletal spine Osteogenic sarcoma - x-ray References ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  2. Bone Biopsy

    MedlinePlus

    ... Physician Resources Professions Site Index A-Z Bone Biopsy Bone biopsy uses a needle and imaging guidance ... limitations of Bone Biopsy? What is a Bone Biopsy? A bone biopsy is an image-guided procedure ...

  3. Renal scan

    MedlinePlus

    ... and urinate often to help remove the radioactive material from the body. How to Prepare for the Test Tell your health care provider if you take ... drink additional fluids before the scan. How the Test will ... into the vein. However, you will not feel the radioactive material. The scanning table may be hard and cold. ...

  4. Hypercalciuric Bone Disease

    NASA Astrophysics Data System (ADS)

    Favus, Murray J.

    2008-09-01

    Hypercalciuria plays an important causal role in many patients with calcium oxalate (CaOx) stones. The source of the hypercalciuria includes increased intestinal Ca absorption and decreased renal tubule Ca reabsorption. In CaOx stone formers with idiopathic hypercalciuria (IH), Ca metabolic balance studies have revealed negative Ca balance and persistent hypercalciuria in the fasting state and during low dietary Ca intake. Bone resorption may also contribute to the high urine Ca excretion and increase the risk of bone loss. Indeed, low bone mass by DEXA scanning has been discovered in many IH patients. Thiazide diuretic agents reduce urine Ca excretion and may increase bone mineral density (BMD), thereby reducing fracture risk. Dietary Ca restriction that has been used unsuccessfully in the treatment of CaOx nephrolithiasis in the past may enhance negative Ca balance and accelerate bone loss. DEXA scans may demonstrate low BMD at the spine, hip, or forearm, with no predictable pattern. The unique pattern of bone histologic changes in IH differs from other causes of low DEXA bone density including postmenopausal osteoporosis, male hypogonadal osteoporosis, and glucocorticoid-induced osteoporosis. Hypercalciuria appears to play an important pathologic role in the development of low bone mass, and therefore correction of urine Ca losses should be a primary target for treatment of the bone disease accompanying IH.

  5. Miscellaneous indications in bone scintigraphy: metabolic bone diseases and malignant bone tumors.

    PubMed

    Cook, Gary J R; Gnanasegaran, Gopinath; Chua, Sue

    2010-01-01

    The diphosphonate bone scan is ideally suited to assess many global, focal or multifocal metabolic bone disorders and there remains a role for conventional bone scintigraphy in metabolic bone disorders at diagnosis, investigation of complications, and treatment response assessment. In contrast, the role of bone scintigraphy in the evaluation of primary malignant bone tumors has reduced with the improvement of morphologic imaging, such as computed tomography and magnetic resonance imaging. However, an increasing role for (18)F-fluorodeoxyglucose positron emission tomography and positron emission tomography/computed tomography is emerging as a functional assessment at diagnosis, staging, and neoadjuvant treatment response assessment.

  6. Bone Surface Mapping Method

    PubMed Central

    Fan, Yifang; Fan, Yubo; Li, Zhiyu; Lv, Changsheng; Zhang, Bo

    2012-01-01

    Bone shape is an important factor to determine the bone's structural function. For the asymmetrically shaped and anisotropically distributed bone in vivo, a surface mapping method is proposed on the bases of its geometric transformation invariance and its uniqueness of the principal axes of inertia. Using spiral CT scanning, we can make precise measurements to bone in vivo. The coordinate transformations lead to the principal axes of inertia, with which the prime meridian and the contour can be set. Methods such as tomographic reconstruction and boundary development are employed so that the surface of bone in vivo can be mapped. Experimental results show that the surface mapping method can reflect the shape features and help study the surface changes of bone in vivo. This method can be applied to research into the surface characteristics and changes of organ, tissue or cell whenever its digitalized surface is obtained. PMID:22412952

  7. Gallium scan

    MedlinePlus

    ... material called gallium and is a type of nuclear medicine exam. A related test is gallium scan ... Brown ML, Forstrom LA, et al. Society of nuclear medicine procedure guideline for gallium scintigraphy in inflammation. ...

  8. CT Scan

    MedlinePlus

    ... exposing your baby to radiation. Reactions to contrast material In certain cases, your doctor may recommend you ... for a few hours before your scan Contrast material A special dye called a contrast material is ...

  9. Bone turnover predicts change in volumetric bone density and bone geometry at the radius in men.

    PubMed

    Pye, S R; Ward, K A; Cook, M J; Laurent, M R; Gielen, E; Borghs, H; Adams, J E; Boonen, S; Vanderschueren, D; Wu, F C; O'Neill, T W

    2017-03-01

    Peripheral quantitative computed tomography scans of the distal and midshaft radius were performed in 514 European men aged 40-79 years at baseline and a median of 4.3 years later. Age-related changes in volumetric bone mineral density (vBMD) and bone geometry were greater in men with higher biochemical markers of bone turnover at baseline.

  10. Living Bones, Strong Bones

    NASA Video Gallery

    In this classroom activity, engineering, nutrition, and physical activity collide when students design and build a healthy bone model of a space explorer which is strong enough to withstand increas...

  11. Bone Cancer

    MedlinePlus

    Cancer that starts in a bone is uncommon. Cancer that has spread to the bone from another ... more common. There are three types of bone cancer: Osteosarcoma - occurs most often between ages 10 and ...

  12. Bone Diseases

    MedlinePlus

    Your bones help you move, give you shape and support your body. They are living tissues that rebuild constantly ... childhood and your teens, your body adds new bone faster than it removes old bone. After about ...

  13. Bone Metastasis

    MedlinePlus

    ... metastasis, surgeons can stabilize the bone using metal plates, screws and nails (orthopedic fixation). Orthopedic fixation can ... that can't be easily reinforced with metal plates or screws, such as pelvic bones and bones ...

  14. [Bone lesion in multiple myeloma].

    PubMed

    Ise, Mikiko; Takagi, Toshiyuki

    2007-12-01

    Bone destruction is a hallmark of multiple myeloma(MM). Almost all MM patients develop osteolytic bone lesions that can cause pathologic fractures and severe bone pain. Osteolytic lesions result from increased bone resorption due to osteoclast stimulation and decreased bone formation due to osteoblast inhibition. Plain radiography, CT, and MRI are established imaging techniques in MM. FDG-PET imaging is promising newer scanning technique under current evaluation. The aggressive features of MM bone lesions have significantly contributed to poor prognosis. Therefore, a systemic approach to analgesia, which includes radiotherapy and orthopedic intervention, must be applied as a part of the comprehensive care plan of MM patient. Bisphosphonates have been shown to reduce vertebral fractures and bone pain.

  15. Head CT scan

    MedlinePlus

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...

  16. Bone and bone turnover.

    PubMed

    Crofton, Patricia M

    2009-01-01

    Children with cancer are exposed to multiple influences that may adversely affect bone health. Some treatments have direct deleterious effects on bone whilst others may have indirect effects mediated through various endocrine abnormalities. Most clinical outcome studies have concentrated on survivors of acute lymphoblastic leukaemia (ALL). There is now good evidence that earlier treatment protocols that included cranial irradiation with doses of 24 Gy or greater may result in growth hormone deficiency and low bone mineral density (BMD) in the lumbar spine and femoral neck. Under current protocols, BMD decreases during intensive chemotherapy and fracture risk increases. Although total body BMD may eventually return to normal after completion of chemotherapy, lumbar spine trabecular BMD may remain low for many years. The implications for long-term fracture risk are unknown. Risk factors for low BMD include high dose methotrexate, higher cumulative doses of glucocorticoids, male gender and low physical activity. BMD outcome in non-ALL childhood cancers has been less well studied but there is evidence that survivors of childhood brain or bone tumours, and survivors of bone marrow transplants for childhood malignancy, all have a high risk of long-term osteopenia. Long-term follow-up is required, with appropriate treatment of any endocrine abnormalities identified.

  17. BoneJ: Free and extensible bone image analysis in ImageJ.

    PubMed

    Doube, Michael; Kłosowski, Michał M; Arganda-Carreras, Ignacio; Cordelières, Fabrice P; Dougherty, Robert P; Jackson, Jonathan S; Schmid, Benjamin; Hutchinson, John R; Shefelbine, Sandra J

    2010-12-01

    Bone geometry is commonly measured on computed tomographic (CT) and X-ray microtomographic (μCT) images. We obtained hundreds of CT, μCT and synchrotron μCT images of bones from diverse species that needed to be analysed remote from scanning hardware, but found that available software solutions were expensive, inflexible or methodologically opaque. We implemented standard bone measurements in a novel ImageJ plugin, BoneJ, with which we analysed trabecular bone, whole bones and osteocyte lacunae. BoneJ is open source and free for anyone to download, use, modify and distribute.

  18. Bone marrow aspiration

    MedlinePlus

    Iliac crest tap; Sternal tap; Leukemia - bone marrow aspiration; Aplastic anemia - bone marrow aspiration; Myelodysplastic syndrome - bone marrow aspiration; Thrombocytopenia - bone marrow aspiration; Myelofibrosis - bone marrow aspiration

  19. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination

    SciTech Connect

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Majoie, Charles B.L.M.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2004-10-01

    In maximum intensity projection (MIP) images of CT angiography (CTA) scans, the arteries are often obscured by bone. A bone removal method is presented that uses an additional, nonenhanced scan to create a mask of the bone by thresholding and dilation. After registration of the CTA scan and the additional scan, the bone in the CTA scan is masked. As the cervical area contains bones that can move with respect to each other, these bones are separated first using a watershed algorithm, and then registered individually. A phantom study was performed to evaluate and quantify the tradeoff between the removal of the bone and the preservation of the arteries contiguous to the bone. The influence of algorithm parameters and scan parameters was studied. The method was clinically evaluated with data sets of 35 patients. Best results were obtained with a threshold of 150 HU and a dilation of 8 in-plane voxels and two out-of-plane voxels. The mean width of the soft tissue layer, which is also masked, was approximately 1 mm. The mAs value of the nonenhanced scan could be reduced from 250 mAs to 65 mAs without a loss of quality. In 32 cases the bones were registered correctly and removed completely. In three cases the bone separation was not completely successful, and consequently the bone was not completely removed. The piecewise matched mask bone elimination method proved to be able to obtain MIP images of the cervical arteries free from overprojecting bone in a fully automatic way and with only a slight increase of radiation dose.

  20. Evidence for arrested bone formation during spaceflight

    NASA Technical Reports Server (NTRS)

    Turner, R. T.; Bobyn, J. D.; Duvall, P.; Morey, E. R.; Baylink, D. J.; Spector, M.

    1982-01-01

    Addressing the question of whether the bone formed in space is unusual, the morphology of bone made at the tibial diaphysis of rats before, during, and after spaceflight is studied. Evidence of arrest lines in the bone formed in space is reported suggesting that bone formation ceases along portions of the periosteum during spaceflight. Visualized by microradiography, the arrest lines are shown to be less mineralized than the surrounding bone matrix. When viewed by scanning electron microscopy, it is seen that bone fractures more readily at the site of an arrest line. These observations are seen as suggesting that arrest lines are a zone of weakness and that their formation may result in decreased bone strength in spite of normalization of bone formation after flight. The occurrence, location, and morphology of arrest lines are seen as suggesting that they are a visible result of the phenomenon of arrested bone formation.

  1. Leg CT scan

    MedlinePlus

    CAT scan - leg; Computed axial tomography scan - leg; Computed tomography scan - leg; CT scan - leg ... scanners can perform the exam without stopping.) A computer creates separate images of the body area, called ...

  2. Arm CT scan

    MedlinePlus

    CAT scan - arm; Computed axial tomography scan - arm; Computed tomography scan - arm; CT scan - arm ... scanners can perform the exam without stopping.) A computer creates separate images of the arm area, called ...

  3. Radionuclide evaluation of nonmalignant bone disorders

    SciTech Connect

    Winzelberg, G.G.

    1983-02-01

    Recent advances in nuclear imaging have improved the noninvasive evaluation of patients with nonmalignant bone disorders. When bone scanning agents are combined with bone marrow scanning agents and gallium-67 scintigraphy, a more accurate diagnosis can be obtained. By selecting the appropriate imaging sequence, it is often possible to distinguish cellulitis from underlying osteomyelitis. In patients with total hip replacements, it may be possible to separate postsurgical changes from prosthetic loosening or infection. Stress fractures in joggers may be detected by radionuclide bone scintigraphy before radiographs become abnormal. These nuclear imaging procedures can be done in most hospitals.

  4. Bone grafts.

    PubMed

    Hubble, Matthew J W

    2002-09-01

    Bone grafts are used in musculoskeletal surgery to restore structural integrity and enhance osteogenic potential. The demand for bone graft for skeletal reconstruction in bone tumor, revision arthroplasty, and trauma surgery, couple with recent advances in understanding and application of the biology of bone transplantation, has resulted in an exponential increase in the number of bone-grafting procedures performed over the last decade. It is estimated that 1.5 million bone-grafting procedures are currently performed worldwide each year, compared to a fraction of that number 20 years ago. Major developments also have resulted in the harvesting, storage, and use of bone grafts and production of graft derivatives, substitutes, and bone-inducing agents.

  5. Bone cement

    PubMed Central

    Vaishya, Raju; Chauhan, Mayank; Vaish, Abhishek

    2013-01-01

    The knowledge about the bone cement is of paramount importance to all Orthopaedic surgeons. Although the bone cement had been the gold standard in the field of joint replacement surgery, its use has somewhat decreased because of the advent of press-fit implants which encourages bone in growth. The shortcomings, side effects and toxicity of the bone cement are being addressed recently. More research is needed and continues in the field of nanoparticle additives, enhanced bone–cement interface etc. PMID:26403875

  6. Bone Analyzer

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The danger of disuse osteoporosis under weightless condition in space led to extensive research into measurements of bone stiffness and mass by the Biomedical Research Division of Ames and Stanford University. Through its Technology Utilization Program, NASA funded an advanced SOBSA, a microprocessor-controlled bone probe system. SOBSA determines bone stiffness by measuring responses to an electromagnetic shaker. With this information, a physician can identify bone disease, measure deterioration and prescribe necessary therapy. The system is now undergoing further testing.

  7. Mechanical stimulation of bone marrow in situ induces bone formation in trabecular explants.

    PubMed

    Birmingham, E; Kreipke, T C; Dolan, E B; Coughlin, T R; Owens, P; McNamara, L M; Niebur, G L; McHugh, P E

    2015-04-01

    Low magnitude high frequency (LMHF) loading has been shown to have an anabolic effect on trabecular bone in vivo. However, the precise mechanical signal imposed on the bone marrow cells by LMHF loading, which induces a cellular response, remains unclear. This study investigates the influence of LMHF loading, applied using a custom designed bioreactor, on bone adaptation in an explanted trabecular bone model, which isolated the bone and marrow. Bone adaptation was investigated by performing micro CT scans pre and post experimental LMHF loading, using image registration techniques. Computational fluids dynamic models were generated using the pre-experiment scans to characterise the mechanical stimuli imposed by the loading regime prior to adaptation. Results here demonstrate a significant increase in bone formation in the LMHF loaded group compared to static controls and media flow groups. The calculated shear stress in the marrow was between 0.575 and 0.7 Pa, which is within the range of stimuli known to induce osteogenesis by bone marrow mesenchymal stem cells in vitro. Interestingly, a correlation was found between the bone formation balance (bone formation/resorption), trabecular number, trabecular spacing, mineral resorption rate, bone resorption rate and mean shear stresses. The results of this study suggest that the magnitude of the shear stresses generated due to LMHF loading in the explanted bone cores has a contributory role in the formation of trabecular bone and improvement in bone architecture parameters.

  8. Bone Infections

    MedlinePlus

    ... bloodstream. People who are at risk for bone infections include those with diabetes, poor circulation, or recent injury to the bone. You may also be at risk if you are having hemodialysis. Symptoms of bone infections include Pain in the infected area Chills and ...

  9. Nuclear scanning in necrotizing progressive ''malignant'' external otitis

    SciTech Connect

    Parisier, S.C.; Lucente, F.E.; Som, P.M.; Hirschman, S.Z.; Arnold, L.M.; Roffman, J.D.

    1982-09-01

    The usefulness of radionuclear scanning in the treatment of 18 patients with necrotizing progressive ''malignant'' external otitis is discussed. A Tc 99-m bone scan, a valuable test since results are positive in early cases of osteomyelitis of the temporal bone and base of skull, showed increased uptake in all 18 patients. In 6 patients, Ga-67 citrate scans were obtained at the start of therapy and at 5-6 week intervals thereafter. The serial gallium scans were useful in evaluating the effectiveness of therapy since the uptake decrease with control of infection.

  10. Bone poroelasticity.

    PubMed

    Cowin, S C

    1999-03-01

    Poroelasticity is a well-developed theory for the interaction of fluid and solid phases of a fluid-saturated porous medium. It is widely used in geomechanics and has been applied to bone by many authors in the last 30 years. The purpose of this work is, first, to review the literature related to the application of poroelasticity to the interstitial bone fluid and, second, to describe the specific physical and modeling considerations that establish poroelasticity as an effective and useful model for deformation-driven bone fluid movement in bone tissue. The application of poroelasticity to bone differs from its application to soft tissues in two important ways. First, the deformations of bone are small while those of soft tissues are generally large. Second, the bulk modulus of the mineralized bone matrix is about six times stiffer than that of the fluid in the pores while the bulk moduli of the soft tissue matrix and the pore water are almost the same. Poroelasticity and electrokinetics can be used to explain strain-generated potentials in wet bone. It is noted that strain-generated potentials can be used as an effective tool in the experimental study of local bone fluid flow, and that the knowledge of this technique will contribute to the answers of a number of questions concerning bone mineralization, osteocyte nutrition and the bone mechanosensory system.

  11. Radionuclide studies of bone metabolism: do bone uptake and bone plasma clearance provide equivalent measurements of bone turnover?

    PubMed

    Blake, Glen M; Siddique, Musib; Frost, Michelle L; Moore, Amelia E B; Fogelman, Ignac

    2011-09-01

    Quantitative radionuclide imaging using (18)F-fluoride positron emission tomography (18F-PET) or (99m)Tc-methylene diphosphonate ((99m)Tc-MDP) bone scans provides a novel tool for studying regional and whole skeleton bone turnover that complements the information provided by biochemical markers. Radionuclide bone scans can be quantified by measuring either tracer uptake or, if blood sampling is performed, bone plasma clearance. This study examines whether these two methods provide equivalent information about bone turnover. We examined data from two clinical trials of the bone anabolic agent teriparatide. In Study 1 twenty osteoporotic women had 18F-PET scans of the lumbar spine at baseline and after 6 months treatment with teriparatide. Bone uptake in the lumbar spine was expressed as standardised uptake values (SUV) and blood samples taken to evaluate plasma clearance. In Study 2 ten women had (99m)Tc-MDP scans at baseline, 3 and 18 months after starting teriparatide. Blood samples were taken and whole skeleton plasma clearance and bone uptake calculated. In Study 1 spine plasma clearance increased by 23.8% after 6-months treatment (P=0.0003), whilst SUV increased by only 3.0% (P=0.84). In Study 2 whole skeleton plasma clearance increased by 37.1% after 18-months treatment (P=0.0002), whilst the 4-hour whole skeleton uptake increased by only 25.5% (P=0.0001). During treatment the 18F- plasma concentration decrease by 20% and (99m)Tc-MDP concentration by 13%, and these latter changes were sufficient to explain the differences between the uptake and plasma clearance results. Measurements of response to treatment using bone uptake and plasma clearance gave different results because the effects of teriparatide on bone resulted in a sufficiently increased demand for radionuclide tracer from the skeleton that the concentration in the circulation decreased. Similar effects may occur with other therapies that have a large enough effect on bone metabolism. In these

  12. A Boon for Bone Research

    NASA Technical Reports Server (NTRS)

    1996-01-01

    NASA studies for astronaut health in long-term space missions led to the development of the Mechanical Response Tissue Analyzer (MRTA), a research tool for astronaut disuse, osteoporosis and related bone disorders among the general population. Ames Research Center and Stanford University generated a workable device and with Gait Scan, Inc., refined and commercialized it. The MRTA is a portable dsinstrument that measures the bending stiffness of bones using electrically-induced vibration and detects and analyzes the frequencies of the resonating bone. Unlike some other methods, the MRTA uses no radiation and is fast, simple and relatively inexpensive.

  13. Symmetry analysis of talus bone

    PubMed Central

    Islam, K.; Dobbe, A.; Komeili, A.; Duke, K.; El-Rich, M.; Dhillon, S.; Adeeb, S.; Jomha, N. M.

    2014-01-01

    Objective The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones. Methods Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified. Results Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery. Conclusions We conclude that left and right talus bones of intact human ankle joints show a strong degree of symmetry. The results of this study may have significance with respect to talus surgery, and in investigating traumatic talus injury where the geometric shape of the contralateral talus can be used as control. Cite this article: Bone Joint Res 2014;3:139–45. PMID:24802391

  14. Calcar bone graft

    SciTech Connect

    Bargar, W.L.; Paul, H.A.; Merritt, K.; Sharkey, N.

    1986-01-01

    A canine model was developed to investigate the use of an autogeneic iliac bone graft to treat the calcar deficiency commonly found at the time of revision surgery for femoral component loosening. Five large male mixed-breed dogs had bilateral total hip arthroplasty staged at three-month intervals, and were sacrificed at six months. Prior to cementing the femoral component, an experimental calcar defect was made, and a bicortical iliac bone graft was fashioned to fill the defect. Serial roentgenograms showed the grafts had united with no resorption. Technetium-99 bone scans showed more uptake at three months than at six months in the graft region. Disulfine blue injection indicated all grafts were perfused at both three and six months. Thin section histology, fluorochromes, and microradiographs confirmed graft viability in all dogs. Semiquantitative grading of the fluorochromes indicated new bone deposition in 20%-50% of each graft at three months and 50%-80% at six months. Although the calcar bone graft was uniformly successful in this canine study, the clinical application of this technique should be evaluated by long-term results in humans.

  15. Knee CT scan

    MedlinePlus

    CAT scan - knee; Computed axial tomography scan - knee; Computed tomography scan - knee ... scanners can perform the exam without stopping.) A computer makes several images of the body area. These ...

  16. HIDA Scan (Cholescintigraphy)

    MedlinePlus

    HIDA scan Overview By Mayo Clinic Staff A hepatobiliary (HIDA) scan is an imaging procedure used to diagnose ... the liver, gallbladder and bile ducts. For a HIDA scan, also known as cholescintigraphy and hepatobiliary scintigraphy, ...

  17. Lumbar spine CT scan

    MedlinePlus

    CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... stopping.) A computer creates separate images of the spine area, called slices. These images can be stored, ...

  18. Coronary Calcium Scan

    MedlinePlus

    ... Scan Coronary Calcium Scan Related Topics Angina Atherosclerosis Coronary Heart Disease Electrocardiogram Heart Attack Send a link to NHLBI ... calcium, or calcifications, are a sign of atherosclerosis, coronary heart disease, or coronary microvascular disease. A coronary calcium scan ...

  19. [Bone diseases].

    PubMed

    Uebelhart, Brigitte; Rizzoli, René

    2016-01-13

    Calcium intake shows a small impact on bone mineral density and fracture risk. Denosumab is a more potent inhibitor of bone resorption than zoledronate. Abaloparatide, PTHrP analog, increases bone mineral density and decreases fracture incidence. Teriparatide could be delivered via a transdermic device. Romosozumab and odanacatib improve calculated bone strength. Sequential or combined treatments with denosumab and teriparatide could be of interest, but not denosumab followed by teriparatide. Fibrous dysplasia, Paget disease and hypophosphatasia are updated, as well as atypical femoral fracture and osteonecrosis of the jaw.

  20. Bone cutting.

    PubMed

    Giraud, J Y; Villemin, S; Darmana, R; Cahuzac, J P; Autefage, A; Morucci, J P

    1991-02-01

    Bone cutting has always been a problem for surgeons because bone is a hard living material, and many osteotomes are still very crude tools. Technical improvement of these surgical tools has first been their motorization. Studies of the bone cutting process have indicated better features for conventional tools. Several non-conventional osteotomes, particularly ultrasonic osteotomes are described. Some studies on the possible use of lasers for bone cutting are also reported. Use of a pressurised water jet is also briefly examined. Despite their advantages, non-conventional tools still require improvement if they are to be used by surgeons.

  1. Diagnostic value of routine bone scintigraphy renal imaging in renal cell carcinoma

    SciTech Connect

    Chancellor, M.B.; Konnak, J.W.; Grossman, H.B.

    1989-05-01

    Technetium-99m-phosphate compounds used in bone scanning are excreted by the kidney, and excellent renal images can be obtained on routine bone scintigrams. The preoperative bone scans of 49 patients who underwent radical nephrectomy for renal cell carcinoma between 1981 and 1985 were reviewed for renal imaging. Ninety-four percent of the patients had abnormal bone scan renal images (82% had focal decreased uptake, and 12% had focal increased uptake). Six percent of the renal images were symmetrical bilaterally. When bone scans are employed in the postoperative follow-up of patients with renal cancer, they can be used to assess the status of the remaining kidney.

  2. Your Bones

    MedlinePlus

    ... shoulder blade or scapula (say: SKA-pyuh-luh), a large triangular bone on the upper back corner of each side of the ribcage. The arm is made up of three bones: the humerus (say: HYOO-muh-rus), which is above your elbow, and the radius (say: RAY-dee-us) and ulna (say: UL- ...

  3. Talking Bones.

    ERIC Educational Resources Information Center

    Johnson, Jaclyn; Kassing, Sharon

    2002-01-01

    Describes cooperation with the Saint Louis Zoo to provide opportunities for elementary school students to learn about bones, how animals move, what they eat, and how much they grow. Uses biofacts which include bones, skulls, and other parts to make the laboratory a hands-on experience for students. (YDS)

  4. Lyotropic liquid crystalline L3 phase silicated nanoporous monolithic composites and their production

    DOEpatents

    McGrath, Kathryn M.; Dabbs, Daniel M.; Aksay, Ilhan A.; Gruner, Sol M.

    2003-10-28

    A mesoporous ceramic material is provided having a pore size diameter in the range of about 10-100 nanometers produced by templating with a ceramic precursor a lyotropic liquid crystalline L.sub.3 phase consisting of a three-dimensional, random, nonperiodic network packing of a multiple connected continuous membrane. A preferred process for producing the inesoporous ceramic material includes producing a template of a lyotropic liquid crystalline L.sub.3 phase by mixing a surfactant, a co-surfactant and hydrochloric acid, coating the template with an inorganic ceramic precursor by adding to the L.sub.3 phase tetramethoxysilane (TMOS) or tetraethoxysilane (TEOS) and then converting the coated template to a ceramic by removing any remaining liquids.

  5. Paget's Disease of Bone

    MedlinePlus

    ... page please turn Javascript on. Paget's Disease of Bone What is Paget's Disease of Bone? Click for more information Enlarged and Misshapen Bones Paget's disease of bone causes affected bones to ...

  6. Automated assessment of exclusion criteria for DXA lumbar spine scans.

    PubMed

    Barden, Howard S; Markwardt, Paul; Payne, Randy; Hawkins, Brent; Frank, Matt; Faulkner, Kenneth G

    2003-01-01

    Modern bone densitometry systems using dual-energy X-ray absorptiometry (DXA) automatically analyze lumbar spine scans and provide clinically important information concerning spine bone mineral density (BMD) and fracture risk. Lumbar spine BMD accurately reflects skeletal health and fracture risk in most cases, but degenerative diseases associated with aging may lead to the formation of reactive bone (osteophytes) and other confounding conditions that elevate BMD without a concomitant increase in bone strength or decrease in fracture risk. Automated densitometry software known as computer-aided densitometry (CAD) (GE Medical Systems Lunar) assists the user in identifying scans with common acquisition and analysis irregularities known to influence BMD values. Visual examination of 231 female spine scans measured with DXA found abnormal conditions that could influence BMD results in 29% of scans. The sensitivity and specificity of several criteria for identifying scans with conditions that could influence BMD were determined. A good criterion for identifying scans with abnormal conditions was a T-score difference of greater than 0.9 or 1.0 between L1-L4 mean and individual vertebrae. Criteria for excluding affected vertebrae were determined. Exclusion of affected vertebrae resulted in a mean BMD decrease of nearly 0.6 SD (T-score) among affected scans.

  7. Dilatational band formation in bone

    PubMed Central

    Poundarik, Atharva A.; Diab, Tamim; Sroga, Grazyna E.; Ural, Ani; Boskey, Adele L.; Gundberg, Caren M.; Vashishth, Deepak

    2012-01-01

    Toughening in hierarchically structured materials like bone arises from the arrangement of constituent material elements and their interactions. Unlike microcracking, which entails micrometer-level separation, there is no known evidence of fracture at the level of bone’s nanostructure. Here, we show that the initiation of fracture occurs in bone at the nanometer scale by dilatational bands. Through fatigue and indentation tests and laser confocal, scanning electron, and atomic force microscopies on human and bovine bone specimens, we established that dilatational bands of the order of 100 nm form as ellipsoidal voids in between fused mineral aggregates and two adjacent proteins, osteocalcin (OC) and osteopontin (OPN). Laser microdissection and ELISA of bone microdamage support our claim that OC and OPN colocalize with dilatational bands. Fracture tests on bones from OC and/or OPN knockout mice (OC−/−, OPN−/−, OC-OPN−/−;−/−) confirm that these two proteins regulate dilatational band formation and bone matrix toughness. On the basis of these observations, we propose molecular deformation and fracture mechanics models, illustrating the role of OC and OPN in dilatational band formation, and predict that the nanometer scale of tissue organization, associated with dilatational bands, affects fracture at higher scales and determines fracture toughness of bone. PMID:23129653

  8. RBC nuclear scan

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  9. Heart PET scan

    MedlinePlus

    Heart nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... Udelson JE, Dilsizian V, Bonow RO. Nuclear cardiology. In: Mann DL, ... A Textbook of Cardiovascular Medicine . 10th ed. Philadelphia, ...

  10. Abdominal CT scan

    MedlinePlus

    Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... 2016:chap 133. Radiologyinfo.org. Computed tomography (CT) - abdomen and pelvis. Updated June 16, 2016. www.radiologyinfo. ...

  11. Cardiac CT Scan

    MedlinePlus

    ... CT Scan Related Topics Aneurysm Coronary Calcium Scan Coronary Heart Disease Heart Attack Pulmonary Embolism Send a link to ... imaging test can help doctors detect or evaluate coronary heart disease, calcium buildup in the coronary arteries, problems with ...

  12. Interpreting Bones.

    ERIC Educational Resources Information Center

    Weymouth, Patricia P.

    1986-01-01

    Describes an activity which introduces students to the nature and challenges of paleoanthropology. In the exercise, students identify diagrammed bones and make interpretations about the creature. Presents questions and tasks employed in the lesson. (ML)

  13. Bone and bone marrow: the same organ.

    PubMed

    Del Fattore, Andrea; Capannolo, Marta; Rucci, Nadia

    2010-11-01

    Interplays between bone and bone marrow are not limited to merely anatomic and histological connections, but include a tight functional correlation. Bone marrow resides within the medullary cavity of the bones and the process of hematopoiesis is regulated, at least in part, by bone cells. Moreover, osteoclasts and osteoblasts derive from precursors of hematopoietic and mesenchymal origin, respectively, both residing within the bone marrow. Alterations in one of these components typically cause impairment in the other, so diseases of the bone marrow compartment often affect the bone and vice versa. All these findings could make us to speculate that bone and bone marrow are not two separate districts, but can be considered as the two elements of the same unique functional unit, the bone-bone marrow organ. Here we will describe histological and functional interplays between bone and bone marrow, and will illustrate some diseases in which this tight correlation is evident.

  14. Multipurpose binocular scanning apparatus

    NASA Technical Reports Server (NTRS)

    Chamberlain, F. R.; Parker, G. L.

    1969-01-01

    Optical gimballing apparatus directs narrow fields of view throughout solid angle approaching 4 pi steradians. Image rotation produced by scanning can be eliminated or altered by gear trains directly linked to the scanning drive assembly. It provides the basis for a binocular scanning capability.

  15. Rapid frequency scan EPR.

    PubMed

    Tseitlin, Mark; Rinard, George A; Quine, Richard W; Eaton, Sandra S; Eaton, Gareth R

    2011-08-01

    In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x, y plane decays to baseline at the end of the scan, which typically is about 5T(2) after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5T(2). However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded with a total scan period of 5T(2), even if some spins are excited later in the scan. This scan time is similar to polyphase excitation methods. The peak power required for either polyphase excitation or rapid frequency scans is substantially smaller than for pulsed EPR. The use of an arbitrary waveform generator (AWG) and cross loop resonator facilitated implementation of the rapid frequency scan experiments reported here. The use of constant continuous low B(1), periodic excitation waveform, and constant external magnetic field is similar to polyphase excitation, but could be implemented without the AWG that is required for polyphase excitation.

  16. Rapid Frequency Scan EPR

    PubMed Central

    Tseitlin, Mark; Rinard, George A.; Quine, Richard W.; Eaton, Sandra S.; Eaton, Gareth R.

    2011-01-01

    In rapid frequency scan EPR with triangular scans, sufficient time must be allowed to insure that the magnetization in the x,y plane decays to baseline at the end of the scan, which typically is about 5 T2 after the spins are excited. To permit relaxation of signals excited toward the extremes of the scan the total scan time required may be much longer than 5 T2. However, with periodic, saw-tooth excitation, the slow-scan EPR spectrum can be recovered by Fourier deconvolution of data recorded with a total scan period of 5 T2, even if some spins are excited later in the scan. This scan time is similar to polyphase excitation methods. The peak power required for either polyphase excitation or rapid frequency scans is substantially smaller than for pulsed EPR. The use of an arbitrary waveform generator (AWG) and cross loop resonator facilitated implementation of the rapid frequency scan experiments reported here. The use of constant continuous low B1, periodic excitation waveform, and constant external magnetic field is similar to polyphase excitation, but could be implemented without the AWG that is required for polyphase excitation. PMID:21664848

  17. Line-scanning, stage scanning confocal microscope

    NASA Astrophysics Data System (ADS)

    Carucci, John A.; Stevenson, Mary; Gareau, Daniel

    2016-03-01

    We created a line-scanning, stage scanning confocal microscope as part of a new procedure: video assisted micrographic surgery (VAMS). The need for rapid pathological assessment of the tissue on the surface of skin excisions very large since there are 3.5 million new skin cancers diagnosed annually in the United States. The new design presented here is a confocal microscope without any scanning optics. Instead, a line is focused in space and the sample, which is flattened, is physically translated such that the line scans across its face in a direction perpendicular to the line its self. The line is 6mm long and the stage is capable of scanning 50 mm, hence the field of view is quite large. The theoretical diffraction-limited resolution is 0.7um lateral and 3.7um axial. However, in this preliminary report, we present initial results that are a factor of 5-7 poorer in resolution. The results are encouraging because they demonstrate that the linear array detector measures sufficient signal from fluorescently labeled tissue and also demonstrate the large field of view achievable with VAMS.

  18. Bone marrow transplant

    MedlinePlus

    Transplant - bone marrow; Stem cell transplant; Hematopoietic stem cell transplant; Reduced intensity nonmyeloablative transplant; Mini transplant; Allogenic bone marrow transplant; Autologous bone marrow transplant; ...

  19. Hyoid bone fusion and bone density across the lifespan: prediction of age and sex.

    PubMed

    Fisher, Ellie; Austin, Diane; Werner, Helen M; Chuang, Ying Ji; Bersu, Edward; Vorperian, Houri K

    2016-06-01

    The hyoid bone supports the important functions of swallowing and speech. At birth, the hyoid bone consists of a central body and pairs of right and left lesser and greater cornua. Fusion of the greater cornua with the body normally occurs in adulthood, but may not occur at all in some individuals. The aim of this study was to quantify hyoid bone fusion across the lifespan, as well as assess developmental changes in hyoid bone density. Using a computed tomography imaging studies database, 136 hyoid bones (66 male, 70 female, ages 1-to-94) were examined. Fusion was ranked on each side and hyoid bones were classified into one of four fusion categories based on their bilateral ranks: bilateral distant non-fusion, bilateral non-fusion, partial or unilateral fusion, and bilateral fusion. Three-dimensional hyoid bone models were created and used to calculate bone density in Hounsfield units. Results showed a wide range of variability in the timing and degree of hyoid bone fusion, with a trend for bilateral non-fusion to decrease after age 20. Hyoid bone density was significantly lower in adult female scans than adult male scans and decreased with age in adulthood. In sex and age estimation models, bone density was a significant predictor of sex. Both fusion category and bone density were significant predictors of age group for adult females. This study provides a developmental baseline for understanding hyoid bone fusion and bone density in typically developing individuals. Findings have implications for the disciplines of forensics, anatomy, speech pathology, and anthropology.

  20. Bone densitometry in infants

    SciTech Connect

    Barden, H.S.; Mazess, R.B.

    1988-07-01

    Bone mineral mass and density can be measured noninvasively by various absorptiometric procedures. Two methods, dual-photon absorptiometry (DPA) and quantitative computed tomography, have widespread application in adults but only limited use in children. One method, single-photon absorptiometry (SPA), has been used extensively in adults and children and has been modified for use in infants. The radius shaft has been used for most research on infants. However, the difficulty of using older SPA methods on this small bone (4 to 7 mm width) has led a few investigators to measure the shaft of the humerus. The typical precision of measurement in a newborn is about 5% with the use of computerized rectilinear scanners for the radius; older linear scanners have a precision error of 5% to 10% on the humerus. Linear scanners cannot measure precisely the radius in individual neonates. The SPA scans typically take about 5 minutes. The DPA technique using /sup 153/Gd has been modified for use on smaller animals (5 to 10 kg monkeys and dogs), but it has not been used on infants because DPA scans take 20 minutes. New methods using x-ray absorptiometry allow rapid (1 minute), precise (1%) measurements in the perinate. The need for a soft tissue bolus is eliminated, and both the axial and peripheral skeletons can be measured with dual-energy x-ray absorptiometry. Ultrasonic measurements do not yet offer adequate precision in the neonate, given the limited biologic range of values. 83 references.

  1. Digital radiographic localization for CT scanning of the larynx

    SciTech Connect

    Silverman, P.M.; Korobkin, M.; Rauch, R.F.

    1983-12-01

    Computed tomography (CT) of the larynx is the preferred method for staging laryngeal carcinoma and assessing the extent of injury from trauma. The standard method of examination consists of 5 mm contiguous scans throughout the larynx in quiet respiration. Scans are performed with the patient supine with the neck slightly extended allowing the long axis of the larynx to be perpendicular to the scanning plane. A complete examination requires scanning from the supraglottic region (level of hyoid bone) to the subglottic region (level of cricoid cartlage). In the authors' experience when this method is used, multiple scans are performed cephalad to the level of interest because no upper limit of the examination is established before transaxial scans are done. We have used the lateral digital radiograph of the neck to identify specific landmarks so that the upper and lower limets of the examination can be established before scanning.

  2. Remnant Woven Bone and Calcified Cartilage in Mouse Bone: Differences between Ages/Sex and Effects on Bone Strength

    PubMed Central

    Ip, Victoria; Toth, Zacharie; Chibnall, John; McBride-Gagyi, Sarah

    2016-01-01

    Introduction Mouse models are used frequently to study effects of bone diseases and genetic determinates of bone strength. Murine bones have an intracortical band of woven bone that is not present in human bones. This band is not obvious under brightfield imaging and not typically analyzed. Due to the band’s morphology and location it has been theorized to be remnant bone from early in life. Furthermore, lamellar and woven bone are well known to have differing mechanical strengths. The purpose of this study was to determine (i) if the band is from early life and (ii) if the woven bone or calcified cartilage contained within the band affect whole bone strength. Woven Bone Origin Studies In twelve to fourteen week old mice, doxycycline was used to label bone formed prior to 3 weeks old. Doxycycline labeling and woven bone patterns on contralateral femora matched well and encompassed an almost identical cross-sectional area. Also, we highlight for the first time in mice the presence of calcified cartilage exclusively within the band. However, calcified cartilage could not be identified on high resolution cone-beam microCT scans when examined visually or by thresholding methods. Mechanical Strength Studies Subsequently, three-point bending was used to analyze the effects of woven bone and calcified cartilage on whole bone mechanics in a cohort of male and female six and 13 week old Balb/C mice. Three-point bending outcomes were correlated with structural and compositional measures using multivariate linear regression. Woven bone composed a higher percent of young bones than older bones. However, calcified cartilage in older bones was twice that of younger bones, which was similar when normalized by area. Area and/or tissue mineral density accounted for >75% of variation for most strength outcomes. Percent calcified cartilage added significant predictive power to maximal force and bending stress. Calcified cartilage and woven bone could have more influence in genetic

  3. Association between Bone Mass and Dental Hypomineralization.

    PubMed

    van der Tas, J T; Elfrink, M E C; Vucic, S; Heppe, D H M; Veerkamp, J S J; Jaddoe, V W V; Rivadeneira, F; Hofman, A; Moll, H A; Wolvius, E B

    2016-04-01

    The aim of this study was to examine the association between the bone mass (bone mineral content [BMC]) and hypomineralized second primary molars (HSPMs)/molar incisor hypomineralization (MIH) in 6-y-old children. This cross-sectional study was embedded in the Generation R Study, a population-based prospective cohort study, starting from fetal life until adulthood in Rotterdam, Netherlands. The European Academy of Pediatric Dentistry criteria were used to score the intraoral photographs on the presence or absence of HSPMs and MIH. Bone mass was measured with a dual-energy x-ray absorptiometry (DXA) scan. Intraoral photographs and DXA scans were available in 6,510 6-y-old children. Binary logistic regression models were used to study the association between the bone mass and HSPMs/MIH. In total, 5,586 children had their second primary molars assessed and a DXA scan made; 507 children were diagnosed with HSPM. Of 2,370 children with data on their permanent first molars, 203 were diagnosed with MIH. In the fully adjusted model, children with lower BMC (corrected for bone area) were more likely to have HSPMs (odds ratio, 1.13; 95% confidence interval, 1.02 to 1.26 per 1-standard deviation decrease). A lower BMC (corrected for bone area) was not associated with MIH (odds ratio, 1.02; 95% confidence interval, 0.87 to 1.20 per 1-standard deviation decrease). We observed a negative association between BMC (corrected for bone area) and HSPMs. No association was found between BMC (corrected for bone area) and MIH. Future research should focus on investigating the mechanism underlying the negative association between the bone mass and HSPMs. Our study, in a large population of 6-y-old children, adds the finding that BMC (corrected for bone size) is associated with HSPMs but not with MIH in childhood.

  4. Renal Cell Carcinoma Metastasized to Pagetic Bone

    PubMed Central

    Ramirez, Ashley; Liu, Bo; Rop, Baiywo; Edison, Michelle; Valente, Michael

    2016-01-01

    Paget’s disease of the bone, historically known as osteitis deformans, is an uncommon disease typically affecting individuals of European descent. Patients with Paget’s disease of the bone are at increased risk for primary bone neoplasms, particularly osteosarcoma. Many cases of metastatic disease to pagetic bone have been reported. However, renal cell carcinoma metastasized to pagetic bone is extremely rare. A 94-year-old male presented to the emergency department complaining of abdominal pain. A computed tomography scan of the abdomen demonstrated a large mass in the right kidney compatible with renal cell carcinoma. The patient was also noted to have Paget’s disease of the pelvic bones and sacrum. Within the pagetic bone of the sacrum, there was an enhancing mass compatible with renal cell carcinoma. A subsequent biopsy of the renal lesion confirmed renal cell carcinoma. Paget’s disease of the bone places the patient at an increased risk for bone neoplasms. The most commonly reported sites for malignant transformation are the femur, pelvis, and humerus. In cases of malignant transformation, osteosarcoma is the most common diagnosis. Breast, lung, and prostate carcinomas are the most common to metastasize to pagetic bone. Renal cell carcinoma associated with Paget’s disease of the bone is very rare, with only one prior reported case. Malignancy in Paget's disease of the bone is uncommon with metastatic disease to pagetic bone being extremely rare. We report a patient diagnosed with concomitant renal cell carcinoma and metastatic disease within Paget’s disease of the sacrum. Further research is needed to assess the true incidence of renal cell carcinoma associated with pagetic bone. PMID:27660736

  5. Breast PET scan

    MedlinePlus

    ... Date 8/31/2014 Updated by: Yi-Bin Chen, MD, Leukemia/Bone Marrow Transplant Program, Massachusetts General ... the Health on the Net Foundation (www.hon.ch). The information provided herein should not be used ...

  6. Engineering anatomically shaped human bone grafts.

    PubMed

    Grayson, Warren L; Fröhlich, Mirjam; Yeager, Keith; Bhumiratana, Sarindr; Chan, M Ete; Cannizzaro, Christopher; Wan, Leo Q; Liu, X Sherry; Guo, X Edward; Vunjak-Novakovic, Gordana

    2010-02-23

    The ability to engineer anatomically correct pieces of viable and functional human bone would have tremendous potential for bone reconstructions after congenital defects, cancer resections, and trauma. We report that clinically sized, anatomically shaped, viable human bone grafts can be engineered by using human mesenchymal stem cells (hMSCs) and a "biomimetic" scaffold-bioreactor system. We selected the temporomandibular joint (TMJ) condylar bone as our tissue model, because of its clinical importance and the challenges associated with its complex shape. Anatomically shaped scaffolds were generated from fully decellularized trabecular bone by using digitized clinical images, seeded with hMSCs, and cultured with interstitial flow of culture medium. A bioreactor with a chamber in the exact shape of a human TMJ was designed for controllable perfusion throughout the engineered construct. By 5 weeks of cultivation, tissue growth was evidenced by the formation of confluent layers of lamellar bone (by scanning electron microscopy), markedly increased volume of mineralized matrix (by quantitative microcomputer tomography), and the formation of osteoids (histologically). Within bone grafts of this size and complexity cells were fully viable at a physiologic density, likely an important factor of graft function. Moreover, the density and architecture of bone matrix correlated with the intensity and pattern of the interstitial flow, as determined in experimental and modeling studies. This approach has potential to overcome a critical hurdle-in vitro cultivation of viable bone grafts of complex geometries-to provide patient-specific bone grafts for craniofacial and orthopedic reconstructions.

  7. Dynamic CT scanning of spinal column trauma

    SciTech Connect

    Brown, B.M.; Brant-Zawadzki, M.; Cann, C.E.

    1982-12-01

    Dynamic sequential computed tomographic scanning with automatic table incrementation uses low milliampere-second technique to eliminate tube cooling delays between scanning slices and, thus, markedly shortens examination times. A total of 25 patients with spinal column trauma involving 28 levels were studied with dynamic scans and retrospectively reviewed. Dynamic studies were considerably faster than conventional spine examinations and yielded reliable diagnosis. Bone disruption and subluxation was accurately evaluated, and the use of intrathecal metrizamide in low doses allowed direct visualization of spinal cord or radicular compromise. Multiplanar image reformation was aided by the dynamic incrementation technique, since motion between slices (and the resulting misregistration artifact on image reformation) was minimized. A phantom was devised to test spatial resolution of computed tomography for objects 1-3 mm in size and disclosed minimal differences for dynamic and conventional computed tomographic techniques in resolving medium-to-high-contrast objects.

  8. Broken Bones (For Parents)

    MedlinePlus

    ... Feeding Your 1- to 2-Year-Old Broken Bones KidsHealth > For Parents > Broken Bones Print A A ... bone fragments in place. When Will a Broken Bone Heal? Fractures heal at different rates, depending upon ...

  9. Bone lesion biopsy

    MedlinePlus

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  10. Bone biopsy (image)

    MedlinePlus

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  11. Surgery for Bone Cancer

    MedlinePlus

    ... amputation. This is called limb-salvage or limb-sparing surgery . In going over treatment options, it is ... 2016 Treating Bone Cancer Surgery for Bone Cancer Radiation Therapy for Bone Cancer Chemotherapy for Bone Cancer Targeted ...

  12. Facts about Broken Bones

    MedlinePlus

    ... Room? What Happens in the Operating Room? Broken Bones KidsHealth > For Kids > Broken Bones Print A A ... sticking through the skin . What Happens When a Bone Breaks? It hurts to break a bone! It's ...

  13. Imaging of giant cell tumor of bone

    PubMed Central

    Purohit, Shaligram; Pardiwala, Dinshaw N

    2007-01-01

    Giant cell tumor (GCT) of bone is a benign but locally aggressive and destructive lesion generally occurring in skeletally mature individuals. Typically involving the epiphysiometaphyseal region of long bones, the most common sites include the distal femur, proximal tibia and distal radius. On radiographs, GCT demonstrates a lytic lesion centered in the epiphysis but involving the metaphysis and extending at least in part to the adjacent articular cortex. Most are eccentric, but become symmetric and centrally located with growth. Most cases show circumscribed borders or so-called geographical destruction with no periosteal reaction unless a pathological fracture is present. There is no mineralized tumor matrix. Giant cell tumor can produce wide-ranging appearances depending on site, complications such as hemorrhage or pathological fracture and after surgical intervention. This review demonstrates a spectrum of these features and describes the imaging characteristics of GCT in conventional radiographs, computerized tomography scans, magnetic resonance imaging, bone scans, positron emission tomography scans and angiography. PMID:21139758

  14. Negative radionuclide scan in osteoid osteoma. A case report

    SciTech Connect

    Fehring, T.K.; Green, N.E.

    1984-05-01

    Advances in radionuclide imaging have facilitated the accurate diagnosis and surgical excision of osteoid osteoma. While radionuclide imaging has been inconsistent in the diagnosis of certain problems, its accuracy in the diagnosis of osteoid osteoma has been frequently stressed. To date, no case of a negative bone scan in the presence of a histologically proven osteoid osteoma has been reported. The present case report emphasizes that a negative bone scan does not preclude the diagnosis of osteoid osteoma. Clinical suspicion remains the most sensitive indicator of this lesion.

  15. Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

    NASA Technical Reports Server (NTRS)

    Spector, E.; LeBlanc, A.; Shackelford, L.

    1995-01-01

    This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between

  16. Assumption or Fact? Line-to-Neutral Voltage Expression in an Unbalanced 3-Phase Circuit during Inverter Switching

    ERIC Educational Resources Information Center

    Masrur, M. A.

    2009-01-01

    This paper discusses the situation in a 3-phase motor or any other 3-phase system operating under unbalanced operating conditions caused by an open fault in an inverter switch. A dc voltage source is assumed as the input to the inverter, and under faulty conditions of the inverter switch, the actual voltage applied between the line to neutral…

  17. Resonant scanning mechanism

    NASA Astrophysics Data System (ADS)

    Wallace, John; Newman, Mike; Gutierrez, Homero; Hoffman, Charlie; Quakenbush, Tim; Waldeck, Dan; Leone, Christopher; Ostaszewski, Miro

    2014-10-01

    Ball Aerospace & Technologies Corp. developed a Resonant Scanning Mechanism (RSM) capable of combining a 250- Hz resonant scan about one axis with a two-hertz triangular scan about the orthogonal axis. The RSM enables a rapid, high-density scan over a significant field of regard (FOR) while minimizing size, weight, and power requirements. The azimuth scan axis is bearing mounted allowing for 30° of mechanical travel, while the resonant elevation axis is flexure and spring mounted with five degrees of mechanical travel. Pointing-knowledge error during quiescent static pointing at room temperature across the full range is better than 100 μrad RMS per axis. The compact design of the RSM, roughly the size of a soda can, makes it an ideal mechanism for use on low-altitude aircraft and unmanned aerial vehicles. Unique aspects of the opto-mechanical design include i) resonant springs which allow for a high-frequency scan axis with low power consumption; and ii) an independent lower-frequency scan axis allowing for a wide FOR. The pointing control system operates each axis independently and employs i) a position loop for the azimuth axis; and ii) a unique combination of parallel frequency and amplitude control loops for the elevation axis. All control and pointing algorithms are hosted on a 200-MHz microcontroller with 516 KB of RAM on a compact 3"×4" digital controller, also of Ball design.

  18. A quantification strategy for missing bone mass in case of osteolytic bone lesions

    SciTech Connect

    Fränzle, Andrea Giske, Kristina; Bretschi, Maren; Bäuerle, Tobias; Hillengass, Jens; Bendl, Rolf

    2013-12-15

    Purpose: Most of the patients who died of breast cancer have developed bone metastases. To understand the pathogenesis of bone metastases and to analyze treatment response of different bone remodeling therapies, preclinical animal models are examined. In breast cancer, bone metastases are often bone destructive. To assess treatment response of bone remodeling therapies, the volumes of these lesions have to be determined during the therapy process. The manual delineation of missing structures, especially if large parts are missing, is very time-consuming and not reproducible. Reproducibility is highly important to have comparable results during the therapy process. Therefore, a computerized approach is needed. Also for the preclinical research, a reproducible measurement of the lesions is essential. Here, the authors present an automated segmentation method for the measurement of missing bone mass in a preclinical rat model with bone metastases in the hind leg bones based on 3D CT scans. Methods: The affected bone structure is compared to a healthy model. Since in this preclinical rat trial the metastasis only occurs on the right hind legs, which is assured by using vessel clips, the authors use the left body side as a healthy model. The left femur is segmented with a statistical shape model which is initialised using the automatically segmented medullary cavity. The left tibia and fibula are segmented using volume growing starting at the tibia medullary cavity and stopping at the femur boundary. Masked images of both segmentations are mirrored along the median plane and transferred manually to the position of the affected bone by rigid registration. Affected bone and healthy model are compared based on their gray values. If the gray value of a voxel indicates bone mass in the healthy model and no bone in the affected bone, this voxel is considered to be osteolytic. Results: The lesion segmentations complete the missing bone structures in a reasonable way. The mean

  19. Bone image segmentation.

    PubMed

    Liu, Z Q; Liew, H L; Clement, J G; Thomas, C D

    1999-05-01

    Characteristics of microscopic structures in bone cross sections carry essential clues in age determination in forensic science and in the study of age-related bone developments and bone diseases. Analysis of bone cross sections represents a major area of research in bone biology. However, traditional approaches in bone biology have relied primarily on manual processes with very limited number of bone samples. As a consequence, it is difficult to reach reliable and consistent conclusions. In this paper we present an image processing system that uses microstructural and relational knowledge present in the bone cross section for bone image segmentation. This system automates the bone image analysis process and is able to produce reliable results based on quantitative measurements from a large number of bone images. As a result, using large databases of bone images to study the correlation between bone structural features and age-related bone developments becomes feasible.

  20. Spectroscopic and Structural Investigations of alpha-beta-, and gamma-AIH3 Phases

    SciTech Connect

    Manciu, F.S.; Graetz, J.; Reza, L.; Durrer, W.G.; Bronson, A.; Lacina, D.

    2010-07-01

    With its reputation as a high-energy density fuel, aluminum hydride (AlH{sub 3}) has received renewed attention as a material that is particularly suitable, not only for hydrogen storage but also for rocket propulsion. While the various phases of AlH{sub 3} have been investigated theoretically, there is a shortage of experimental studies corroborating the theoretical findings. In response to this, we present here an investigation of these compounds based primarily on two research areas in which there is the greatest scarcity of information in the literature, namely Raman and infrared (IR) absorption analysis. To the authors knowledge, this is the first report of experimental far-IR absorption results on these compounds. Two different samples prepared by broadly similar ethereal reactions of AlCl{sub 3} with LiAlH{sub 4} were analyzed. Both Raman and IR absorption measurements indicate that one sample is purely {gamma}-AlH{sub 3} and that the other is a mixture of {alpha}-, {beta}-, and {gamma}-AlH{sub 3} phases. X-ray diffraction confirms the spectroscopic findings, most notably for the {beta}-AlH{sub 3} phase, for which optical spectroscopic data are reported here for the first time.

  1. Nuclear Heart Scan

    MedlinePlus

    ... into your blood and travels to your heart. Nuclear heart scans use single photon emission computed tomography (SPECT) or cardiac positron emission tomography (PET) to detect the energy from the tracer to make pictures of your ...

  2. Slow Scan Telemedicine

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

  3. Photothermal imaging scanning microscopy

    DOEpatents

    Chinn, Diane; Stolz, Christopher J.; Wu, Zhouling; Huber, Robert; Weinzapfel, Carolyn

    2006-07-11

    Photothermal Imaging Scanning Microscopy produces a rapid, thermal-based, non-destructive characterization apparatus. Also, a photothermal characterization method of surface and subsurface features includes micron and nanoscale spatial resolution of meter-sized optical materials.

  4. Thoracic spine CT scan

    MedlinePlus

    ... Narrowing of the spine ( spinal stenosis ) Scoliosis Tumor Risks Risks of CT scans include: Exposure to radiation ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  5. Brain PET scan

    MedlinePlus

    ... Tell the difference between Parkinson disease and other movement disorders Several PET scans may be taken to determine ... identify where the seizures start in your brain Movement disorders (such as Parkinson disease )

  6. Cervical MRI scan

    MedlinePlus

    ... magnetic resonance imaging) scan uses energy from strong magnets to create pictures of the part of the ... in your eyes) Because the MRI contains strong magnets, metal objects are not allowed into the room ...

  7. Leg MRI scan

    MedlinePlus

    ... resonance imaging) scan of the leg uses strong magnets to create pictures of the leg. This may ... in your eyes) Because the MRI contains strong magnets, metal objects are not allowed into the room ...

  8. Arm MRI scan

    MedlinePlus

    ... arm MRI (magnetic resonance imaging) scan uses strong magnets to create pictures of the upper and lower ... in your eyes) Because the MRI contains strong magnets, metal objects are not allowed into the room ...

  9. Thyroid Scan and Uptake

    MedlinePlus Videos and Cool Tools

    ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  10. Pediatric CT Scans

    Cancer.gov

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  11. Fiber-Scanned Microdisplays

    NASA Technical Reports Server (NTRS)

    Crossman-Bosworth, Janet; Seibel, Eric

    2010-01-01

    Helmet- and head-mounted display systems, denoted fiber-scanned microdisplays, have been proposed to provide information in an "augmented reality" format (meaning that the information would be optically overlaid on the user's field of view).

  12. Mechanical Loading Attenuates Radiation-Induced Bone Loss in Bone Marrow Transplanted Mice

    PubMed Central

    Govey, Peter M.; Zhang, Yue; Donahue, Henry J.

    2016-01-01

    Exposure of bone to ionizing radiation, as occurs during radiotherapy for some localized malignancies and blood or bone marrow cancers, as well as during space travel, incites dose-dependent bone morbidity and increased fracture risk. Rapid trabecular and endosteal bone loss reflects acutely increased osteoclastic resorption as well as decreased bone formation due to depletion of osteoprogenitors. Because of this dysregulation of bone turnover, bone’s capacity to respond to a mechanical loading stimulus in the aftermath of irradiation is unknown. We employed a mouse model of total body irradiation and bone marrow transplantation simulating treatment of hematologic cancers, hypothesizing that compression loading would attenuate bone loss. Furthermore, we hypothesized that loading would upregulate donor cell presence in loaded tibias due to increased engraftment and proliferation. We lethally irradiated 16 female C57Bl/6J mice at age 16 wks with 10.75 Gy, then IV-injected 20 million GFP(+) total bone marrow cells. That same day, we initiated 3 wks compression loading (1200 cycles 5x/wk, 10 N) in the right tibia of 10 of these mice while 6 mice were irradiated, non-mechanically-loaded controls. As anticipated, before-and-after microCT scans demonstrated loss of trabecular bone (-48.2% Tb.BV/TV) and cortical thickness (-8.3%) at 3 wks following irradiation. However, loaded bones lost 31% less Tb.BV/TV and 8% less cortical thickness (both p<0.001). Loaded bones also had significant increases in trabecular thickness and tissue mineral densities from baseline. Mechanical loading did not affect donor cell engraftment. Importantly, these results demonstrate that both cortical and trabecular bone exposed to high-dose therapeutic radiation remain capable of an anabolic response to mechanical loading. These findings inform our management of bone health in cases of radiation exposure. PMID:27936104

  13. Bone pulsating metastasis due to renal cell carcinoma.

    PubMed

    Cınar, Murat; Derincek, Alihan; Karan, Belgin; Akpınar, Sercan; Tuncay, Cengiz

    2010-11-01

    Pulsation on the bone cortex surface is a rare condition. Pulsative palpation of the superficial-located bone tumors can be misperceived as an aneurysm. Fifty-eight-year-old man is presented with pulsating bone mass in his proximal tibia. During angiographic examination, hypervascular masses were diagnosed both at right kidney and at right proximal tibia. Renal cell carcinoma was diagnosed after abdominal CT scan. Proximal tibia biopsy was complicated with projectile bleeding.

  14. Multiple Reflector Scanning Antennas

    NASA Astrophysics Data System (ADS)

    Shen, Bing

    Narrow beamwidth antenna systems are important to remote sensing applications and point-to-point communication systems. In many applications the main beam of the antenna radiation pattern must be scannable over a region of space. Scanning by mechanically skewing the entire antenna assembly is difficult and in many situations is unacceptable. Performance during scan is, of course, also very important. Traditional reflector systems employing the well-focused paraboloidal -shaped main reflector accomplish scan by motion of a few feeds, or by phase steering a focal plane feed array. Such scanning systems can experience significant gain loss. Traditional reflecting systems with a spherical main reflector have low aperture efficiency and poor side lobe and cross polarization performance. This dissertation introduces a new approach to the design of scanning spherical reflector systems, in which the performance weaknesses of high cross polarization and high side lobe levels are avoided. Moreover, the low aperture utilization common in spherical reflectors is overcome. As an improvement to this new spherical main reflector configuration, a flat mirror reflector is introduced to minimize the mechanical difficulties to scan the main beam. In addition to the reflector system design, reflector antenna performance evaluation is also important. The temperature resolution issue important for earth observation radiometer antennas is studied, and a new method to evaluate and optimize such temperature resolution is introduced.

  15. Wide scanning spherical antenna

    NASA Technical Reports Server (NTRS)

    Shen, Bing (Inventor); Stutzman, Warren L. (Inventor)

    1995-01-01

    A novel method for calculating the surface shapes for subreflectors in a suboptic assembly of a tri-reflector spherical antenna system is introduced, modeled from a generalization of Galindo-Israel's method of solving partial differential equations to correct for spherical aberration and provide uniform feed to aperture mapping. In a first embodiment, the suboptic assembly moves as a single unit to achieve scan while the main reflector remains stationary. A feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan thereby eliminating the need to oversize the main spherical reflector. In an alternate embodiment, both the main spherical reflector and the suboptic assembly are fixed. A flat mirror is used to create a virtual image of the suboptic assembly. Scan is achieved by rotating the mirror about the spherical center of the main reflector. The feed horn is tilted during scan to maintain the illuminated area on the main spherical reflector fixed throughout the scan.

  16. An anatomically shaped lower body model for CT scanning of cadaver femurs.

    PubMed

    Tanck, Esther; Deenen, J C W; Huisman, Henk Jan; Kooloos, Jan G; Huizenga, Henk; Verdonschot, Nico

    2010-01-21

    Bone specific, CT-based finite element (FE) analyses have great potential to accurately predict the fracture risk of deteriorated bones. However, it has been shown that differences exist between FE-models of femora scanned in a water basin or scanned in situ within the human body, as caused by differences in measured bone mineral densities (BMD). In this study we hypothesized that these differences can be reduced by re-creating the patient CT-conditions by using an anatomically shaped physical model of the lower body. BMD distributions were obtained from four different femora that were scanned under three conditions: (1) in situ within the cadaver body, (2) in a water basin and (3) in the body model. The BMD of the three scanning protocols were compared at two locations: proximally, in the trabecular bone of the femoral head, and in the cortical bone of the femoral shaft. Proximally, no significant differences in BMD were found between the in situ scans and the scans in the body model, whereas the densities from the water basin scans were on average 10.8% lower than in situ. In the femoral shaft the differences between the three scanning protocols were insignificant. In conclusion, the body model better approached the in situ situation than a water basin. Future studies can use this body model to mimic patient situations and to develop protocols to improve the performance of the FE-models in actual patients.

  17. Pitfalls and Limitations of Radionuclide Planar and Hybrid Bone Imaging.

    PubMed

    Agrawal, Kanhaiyalal; Marafi, Fahad; Gnanasegaran, Gopinath; Van der Wall, Hans; Fogelman, Ignac

    2015-09-01

    The radionuclide (99m)Tc-MDP bone scan is one of the most commonly performed nuclear medicine studies and helps in the diagnosis of different pathologies relating to the musculoskeletal system. With its increasing utility in clinical practice, it becomes more important to be aware of various limitations of this imaging modality to avoid false interpretation. It is necessary to be able to recognize various technical, radiopharmaceutical, and patient-related artifacts that can occur while carrying out a bone scan. Furthermore, several normal variations of tracer uptake may mimic pathology and should be interpreted cautiously. There is an important limitation of a bone scan in metastatic disease evaluation as the inherent mechanism of tracer uptake is not specific for tumor but primarily relies on an osteoblastic response. Thus, it is crucial to keep in mind uptake in benign lesions, which can resemble malignant pathologies. The utility of a planar bone scan in benign orthopedic diseases, especially at sites with complex anatomy, is limited owing to lack of precise anatomical information. SPECT/CT has been significantly helpful in these cases. With wider use of PET/CT and reintroduction of the (18)F-fluoride bone scan, increasing knowledge of potential pitfalls on an (18)F-fluoride bone scan and (18)F-FDG-PET/CT will help in improving the accuracy of clinical reports.

  18. Bone metastasis on Tc99-m sestamibi myocardial perfusion scan

    PubMed Central

    Hatemi, Lachin; Jabi, Feraas

    2015-01-01

    A 75-year-old woman presented to our department for a stress myocardial perfusion imaging study with Tc99m-sestamibi. Incidental focal uptake, found in the left upper anterior chest, was initially felt to be located in the left breast. After additional single-photon CT imaging was performed the same day, extracardiac foci within the ribs, spine, and left lung (worrisome for active metastases) were shown to be present, with the initial focus located within a left rib rather than a breast. A review of previous radiographic and nuclear imaging studies confirmed metastatic disease from recurrent follicular thyroid cancer. Atypical focal extracardiac activity must be closely scrutinized for the possibility of malignancy, as Tc99m-sestamibi (in addition to being myocardium-avid) is tumor-avid. PMID:27190553

  19. Extracellular Vesicle-functionalized Decalcified Bone Matrix Scaffolds with Enhanced Pro-angiogenic and Pro-bone Regeneration Activities

    PubMed Central

    Xie, Hui; Wang, Zhenxing; Zhang, Liming; Lei, Qian; Zhao, Aiqi; Wang, Hongxiang; Li, Qiubai; Cao, Yilin; Jie Zhang, Wen; Chen, Zhichao

    2017-01-01

    Vascularization is crucial for bone regeneration after the transplantation of tissue-engineered bone grafts in the clinical setting. Growing evidence suggests that mesenchymal stem cell (MSC)-derived extracellular vesicles (EVs) are potently pro-angiogenic both in vitro and in vivo. In the current study, we fabricated a novel EV-functionalized scaffold with enhanced pro-angiogenic and pro-bone regeneration activities by coating decalcified bone matrix (DBM) with MSC-derived EVs. EVs were harvested from rat bone marrow-derived MSCs and the pro-angiogenic potential of EVs was investigated in vitro. DBM scaffolds were then coated with EVs, and the modification was verified by scanning electron microscopy and confocal microscopy. Next, the pro-angiogenic and pro-bone regeneration activities of EV-modified scaffolds were evaluated in a subcutaneous bone formation model in nude mice. Micro-computed tomography scanning analysis showed that EV-modified scaffolds with seeded cells enhanced bone formation. Enhanced bone formation was confirmed by histological analysis. Immunohistochemical staining for CD31 proved that EV-modified scaffolds promoted vascularization in the grafts, thereby enhancing bone regeneration. This novel scaffold modification method provides a promising way to promote vascularization, which is essential for bone tissue engineering. PMID:28367979

  20. [The challenges of the bone micro-architecture].

    PubMed

    Rachidi, Mouna; Breban, Sophie; Benhamou, Claude-Laurent

    2008-01-01

    Osteoporosis is a bone disorder that leads to increased fracture risk. It was defined by the World Health Organisation as a decrease of bone mass and a deterioration of bone quality. In clinical practice, the diagnosis of osteoporosis is based on bone mineral density (BMD) measurements assessed by dual energy X-ray absorptiometry. However, BMD assessment is not the only factor that influences bone strength. The main objective is that clinicians can use a combination of risk factors that are easily assessable, for a better prediction of osteoporosis risk fracture. Bone strength reflects both bone density and bone quality. One of the most important determinants of bone quality is the trabecular bone micro-architecture as suggested by the definition of osteoporosis. Moreover, various studies have concluded to the potential clinical interest of the bone micro-architecture. The aim of this article was to review the challenges of bone micro-architecture, characterization tools (morphological analysis, topology, texture) and imaging techniques (X-ray imaging, scanning and MRI) to assess trabecular bone micro-architecture.

  1. Bone Density Test

    MedlinePlus

    Tests and Procedures Bone density test By Mayo Clinic Staff A bone density test determines if you have osteoporosis — a disease that causes bones to ... your bones could be quite weak. A bone density test enhances the accuracy of calculating your risk ...

  2. Proximal Tibial Bone Graft

    MedlinePlus

    ... All Site Content AOFAS / FootCareMD / Treatments Proximal Tibial Bone Graft Page Content What is a bone graft? Bone grafts may be needed for various ... the proximal tibia. What is a proximal tibial bone graft? Proximal tibial bone graft (PTBG) is a ...

  3. Frontal bone fractures.

    PubMed

    Marinheiro, Bruno Henrique; de Medeiros, Eduardo Henrique Pantosso; Sverzut, Cássio Edvard; Trivellato, Alexandre Elias

    2014-11-01

    The aim of this retrospective study was to evaluate the epidemiology, treatment, and complications of frontal bone fractures associated, or not, with other facial fractures. This evaluation also sought to minimize the influence of the surgeon's skills and the preference for any rigid internal fixation system. The files from 3758 patients who attended the Oral and Maxillofacial Surgery Department of the School of Dentistry of Ribeirao Preto, University of Sao Paulo, from March 2004 to November 2011 and presented with facial trauma were scanned, and 52 files were chosen for the review. Eleven (21.15%) of these patients had pure fractures of the frontal bone, and trauma incidence was more prevalent in men (92.3%), whites (61.53%), and adults (50%). Despite the use of helmets at the moment of the trauma, motorcycle crashes were the most common etiological factor (32.69%). Fracture of the anterior wall of the frontal sinus with displacement was the main injury observed (54.9%), and the most common treatment was internal fixation with a plate and screws (45.09%). Postoperative complications were observed in 35.29% of the cases. The therapy applied was effective in handling this type of fracture, and the success rate was comparable to that reported in other published studies.

  4. Nuclear Scans - Multiple Languages: MedlinePlus

    MedlinePlus

    ... sharing features on this page, please enable JavaScript. Arabic (العربية) Chinese - Simplified (简体中文) Chinese - Traditional (繁體中文) French ( ... Русский) Somali (af Soomaali) Spanish (español) Ukrainian (Українська) Arabic (العربية) Bone Scan (Arabic) العربية Bilingual PDF Health ...

  5. Detailed Review and Application of the 3-Phase Self-Limiting Transformer with Magnetic Flux Applied

    NASA Astrophysics Data System (ADS)

    Kosa, Janos

    The paper describes in detail the 3-phase self-limiting transformer with magnetic flux applied and contains measured results. The solution includes two independent iron cores. I applied two pieces of iron cores with 3 limbs on each. One of the iron cores contains the 3 primary coils on the limbs respectively and the other iron core also contains 3 secondary coils. As I use two iron cores the loss, the size, the weight and the cost are higher compared to the conventional transformers but this solution has several advantages. For example, the fault power is less, switching is fast. In the case, when there is no load on the secondary side and primary voltage increases, the arrangement is able to break coupling between the primary and secondary sides. The work has been carried out by me as a novel possibility of application of the principle of magnetic flux constancy in the closed loop.

  6. Stabilization of ZnMnO3 Phase from Sol-gel Synthesized Nitrate Precursors

    SciTech Connect

    Saraf, Laxmikant V.; Nachimuthu, Ponnusamy; Engelhard, Mark H.; Baer, Donald R.

    2010-02-01

    The stabilization and analysis of pure ZnMnO3 spinel phase may help to understand the solubility limits of Mn in ZnO in wurtzite and spinel cubic structures. In this report, synthesis and characterization of stable ZnMnO3 phase is discussed which is extracted from sol-gel synthesis of zinc and manganese nitrate precursors. The reflections at higher diffraction angles for this known cubic system with space group Fd3m were calculated with the help of JADE 8.0 program. High resolution X-ray photoelectron spectroscopy measurements of Mn3p position of ZnMnO3 compared with ZnMn2O4 showed a higher binding energy shift ~0.85 eV indicating Mn4+ valence state in ZnMnO3.

  7. Bone development

    PubMed Central

    Berendsen, Agnes D.; Olsen, Bjorn R.

    2015-01-01

    The development of the vertebrate skeleton reflects its evolutionary history. Cartilage formation came before biomineralization and a head skeleton evolved before the formation of axial and appendicular skeletal structures. This review describes the processes that result in endochondral and intramembranous ossification, the important roles of growth and transcription factors, and the consequences of mutations in some of the genes involved. Following a summary of the origin of cartilage, muscle, and tendon cell lineages in the axial skeleton, we discuss the role of muscle forces in the formation of skeletal architecture and assembly of musculoskeletal functional units. Finally, ontogenetic patterning of bones in response to mechanical loading is reviewed. PMID:26453494

  8. CT-diagnosed severe skull base bone destruction predicts distant bone metastasis in early N-stage nasopharyngeal carcinoma

    PubMed Central

    Yi, Wei; Liu, Zhi-Gang; Li, Xian; Tang, Jiao; Jiang, Chang-Bin; Hu, Jing-Ye; Tu, Zi-Wei; Wang, Hui; Niu, Dao-Li; Xia, Yun-Fei

    2016-01-01

    Bone metastasis is the most frequent type of distant metastasis in nasopharyngeal carcinoma (NPC). In this study, we investigated the correlation between the skull base bone destruction and the distant bone metastasis in patients with NPC. A total of 449 cases with NPC who were diagnosed and had definitive radiotherapy from 2001 to 2006 were enrolled in this study. The skull base bone destruction was diagnosed by computed tomography (CT) in all cases, and 191 patients also underwent magnetic resonance imaging scan. Kaplan–Meier method was adopted to perform the univariate analysis; Cox regression model was used to perform multivariate analysis to determine whether the skull base bone destruction when diagnosed by CT was an independent impact factor of the distant bone metastases. The group with skull base bone destruction had a distant bone metastases rate of 9.0% (14/155), whereas the group without skull base bone destruction had rate of 4.1% (12/294). The multivariate analysis showed that the skull base bone destruction, when diagnosed by CT, was an independent impact factor of the distant bone metastases-free survival in the early N-staging cases, but was not an independent impact factor when diagnosed by MRI. The skull base bone destruction diagnosed by CT in patients with NPC had predictive value for the distant bone metastases, especially for the early N-staging cases. PMID:27895493

  9. Myeloma and bone disease: "the dangerous tango".

    PubMed

    Epstein, Joshua; Walker, Ronald

    2006-04-01

    Osteolytic bone disease is the most debilitating manifestation of myeloma. However, myeloma-induced effects on the bone-active cells in the bone marrow are more than just a manifestation of disease--the myeloma derives essential support from the changed balance between bone-forming and -resorbing cells. This observation has lead to the notion that effective control of myeloma bone disease by reducing osteoclast activity and restoring osteoblast activity will contribute to long-term control of myeloma progression. Unlike osteolysis associated with other tumors that metastasize to bone, myeloma-associated lytic lesions are unique in that they do not repair even after many years in complete remission, reflecting a total loss of osteoblastic activity in areas of myeloma foci, apparently induced by the myeloma. Advances in imaging technology including positron emission tomography-computed tomography scanning allows accurate detection of lytic lesions and the monitoring of treatment effects. Effective antimyeloma therapy combined with anti-osteoclast drugs can halt the progression of osteolysis; in severe cases with vertebral compression fractures, effective physical support in the form of vertebroplasty or kyphoplasty is required for control of function, pain, and stature. Fractures of the long bones are usually treated by intramedullary rod placement. New approaches to enhance osteoblast activity while controlling osteoclast activity currently under investigation may prove effective in controlling lytic bone disease and myeloma progression.

  10. Intraosseous ganglion. Bone imaging with /sup 99m/Tc MDP

    SciTech Connect

    Makhija, M.C.; Lopano, A.J.

    1983-02-01

    Intraosseous ganglia are benign cystic lesions of bone located in close relationship to the articular cartilage. The typical location and roentgenographic appearance of this lesion should permit a diagnosis of this entity which should be considered in the differential diagnosis of benign lesions of bone. Appearance of this lesion on a bone scan is shown in this case report.

  11. [Comparative investigations of osteotropic radionucleides. IV. The dynamics of uptake in normal and abnormal bone (author's transl)].

    PubMed

    Creutzig, H; Gerdts, K G; Creutzig, A

    1977-03-01

    The dynamics of uptake of osteotropic radionucleides in normal and abnormal bone were studied by means of sequential and functional scans. Various phosphate and phosphonate complexes were compared in vivo and in vitro. Only phosphonates were considered as suitable for bone scanning. In normal bones in beagles, radioactivity after HEDP fell to 65% after two hours, but was 105% with 18F. In relation to healing fractures, the curves differ quantitatively and qualitatively. In this situation, functional curves derived from dynamic scans provide a better parallel with histological findings than does static scintigraphy with an uptake quotient. Sequential and functional scanning are able to document the therapeutic effect of irradiation of bone metastases.

  12. Femtosecond scanning tunneling microscope

    SciTech Connect

    Taylor, A.J.; Donati, G.P.; Rodriguez, G.; Gosnell, T.R.; Trugman, S.A.; Some, D.I.

    1998-11-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). By combining scanning tunneling microscopy with ultrafast optical techniques we have developed a novel tool to probe phenomena on atomic time and length scales. We have built and characterized an ultrafast scanning tunneling microscope in terms of temporal resolution, sensitivity and dynamic range. Using a novel photoconductive low-temperature-grown GaAs tip, we have achieved a temporal resolution of 1.5 picoseconds and a spatial resolution of 10 nanometers. This scanning tunneling microscope has both cryogenic and ultra-high vacuum capabilities, enabling the study of a wide range of important scientific problems.

  13. Vector generator scan converter

    DOEpatents

    Moore, J.M.; Leighton, J.F.

    1988-02-05

    High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardware for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold. 7 figs.

  14. Vector generator scan converter

    DOEpatents

    Moore, James M.; Leighton, James F.

    1990-01-01

    High printing speeds for graphics data are achieved with a laser printer by transmitting compressed graphics data from a main processor over an I/O (input/output) channel to a vector generator scan converter which reconstructs a full graphics image for input to the laser printer through a raster data input port. The vector generator scan converter includes a microprocessor with associated microcode memory containing a microcode instruction set, a working memory for storing compressed data, vector generator hardward for drawing a full graphic image from vector parameters calculated by the microprocessor, image buffer memory for storing the reconstructed graphics image and an output scanner for reading the graphics image data and inputting the data to the printer. The vector generator scan converter eliminates the bottleneck created by the I/O channel for transmitting graphics data from the main processor to the laser printer, and increases printer speed up to thirty fold.

  15. Dietary restrictions, bone density, and bone quality.

    PubMed

    Huang, Tsang-hai; Ables, Gene P

    2016-01-01

    Caloric restriction (CR), protein restriction (PR), and specific amino acid restriction (e.g., methionine restriction (MR)) are different dietary interventions that have been confirmed with regard to their comprehensive benefits to metabolism and health. Based on bone densitometric measurements, weight loss induced by dietary restriction is known to be accompanied by reduced areal bone mineral density, bone mass, and/or bone size, and it is considered harmful to bone health. However, because of technological advancements in bone densitometric instruments (e.g., high-resolution X-ray tomography), dietary restrictions have been found to cause a reduction in bone mass/size rather than volumetric bone mineral density. Furthermore, when considering bone quality, bone health consists of diverse indices that cannot be fully represented by densitometric measurements alone. Indeed, there is evidence that moderate dietary restrictions do not impair intrinsic bone material properties, despite the reduction in whole-bone strength because of a smaller bone size. In the present review, we integrate research evidence from traditional densitometric measurements, metabolic status assays (e.g., energy metabolism, oxidative stresses, and inflammatory responses), and biomaterial analyses to provide revised conclusions regarding the effects of CR, PR, and MR on the skeleton.

  16. Experiment M-6: Bone Demineralization

    NASA Technical Reports Server (NTRS)

    Mack, Pauline B.; Vose, George; Vogt, Fred B.; LaChance, Paul A.

    1966-01-01

    Densitometric evaluations of serial radiographs of "normal" subjects have often shown rather frequent changes in bone mass within relatively short periods of time. For this reason it was decided to make two pre-flight and two post flight radiographs of the Gemini V backup crew. In comparing the changes observed preflight and post flight as the conventional os calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. In comparing the changes observed preflight and postflight as the conventional o calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. This is in contract to the 15.1 and 8.9 percent losses observed in the prime crew. It has long been known that the skeletal system experiences a general loss of mineral under immobilization or extended bed rest. However, in both Gemini IV and Gemini V studies, bone mass losses were greater in both the os calcis and phalanx than were shown by the TWU bed-rest subjects during the same period of time. Although the bone mass losses in the 8-day Gemini V flight were generally greater than in the 4-day Gemini IV flight, the information to date is still insufficient to conclude that the losses tend to progress linearly with time, or whether a form of physiological adaptation may occur in longer space flights.

  17. Imaging of the Wormian bones using microcomputed tomography.

    PubMed

    Kozerska, Magdalena; Skrzat, Janusz; Walocha, Jerzy; Wrobel, Andrzej; Leszczynski, Bartosz

    2013-01-01

    Wormian bones are irregular ossicles of small size and reveal fractal pattern of their edges. Their anatomy was visualized in volumetric reconstructions obtained from a series of micro-CT scans. In visual evaluation Wormian bones showed typical anatomy for the calvarial bones. They revealed three-layer composition: the outer and the inner table of the compact bone intervening with the table of the spongy bone. Microcomputed tomography captured all details of the interdigitation of the edge being incorporated into the lambdoid suture and interlocked between opposing edges of the occipital and parietal bones. This modality provided accurate images which allowed delineating morphological differences between the compact bone and the diploe, including vascular channels.

  18. Adaptive Optical Scanning Holography

    PubMed Central

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  19. Adaptive Optical Scanning Holography

    NASA Astrophysics Data System (ADS)

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-02-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably.

  20. Scanning computed confocal imager

    DOEpatents

    George, John S.

    2000-03-14

    There is provided a confocal imager comprising a light source emitting a light, with a light modulator in optical communication with the light source for varying the spatial and temporal pattern of the light. A beam splitter receives the scanned light and direct the scanned light onto a target and pass light reflected from the target to a video capturing device for receiving the reflected light and transferring a digital image of the reflected light to a computer for creating a virtual aperture and outputting the digital image. In a transmissive mode of operation the invention omits the beam splitter means and captures light passed through the target.

  1. Detection of micrometastatic prostate cancer cells in the bone marrow of patients with prostate cancer.

    PubMed Central

    Deguchi, T.; Yang, M.; Ehara, H.; Ito, S.; Nishino, Y.; Takahashi, Y.; Ito, Y.; Shimokawa, K.; Tanaka, T.; Imaeda, T.; Doi, T.; Kawada, Y.

    1997-01-01

    Thirty-five patients with prostate cancer were examined for micrometastases to the bone marrow using reverse transcription-polymerase chain reaction (RT-PCR) with primers specific for the prostate-specific antigen (PSA) gene. Of nine patients with bone metastases detectable by bone scan imaging, five patients had PSA mRNA expression in the bone marrow detectable by RT-PCR. Of 26 patients with negative bone scan findings, seven patients had PSA mRNA expression detectable in the bone marrow. RT-PCR could detect micrometastatic prostate cancer cells in the bone marrow that were not detectable by bone scan imaging. Of 16 patients with a serum PSA concentration of 25 ng ml(-1) or greater, only nine (56.3%) had bone metastases detected by bone scans. Of the remaining seven patients, five had micrometastases to the bone marrow detected by RT-PCR. Overall, 14 of 16 patients (87.5%) with a serum PSA concentration of 25 ng ml(-1) or greater had metastatic bone diseases including bone marrow micrometastases. Of 19 patients with a serum PSA concentration of less than 25 ng ml(-1), two (10.5%) had only micrometastatic disease detected by RT-PCR. A significant correlation was observed between the incidence of bone involvement and the serum PSA concentration. This study suggests that RT-PCR will potentially develop into a relevant tool to assess bone involvement including bone marrow micrometastases and establish a precise correlation between serum PSA concentration and metastatic bone disease in patients with prostate cancer. Images Figure 1 PMID:9043017

  2. Bone marrow transplant - discharge

    MedlinePlus

    Transplant - bone marrow - discharge; Stem cell transplant - discharge; Hematopoietic stem cell transplant - discharge; Reduced intensity; Non-myeloablative transplant - discharge; Mini transplant - discharge; Allogenic bone marrow transplant - ...

  3. Splenic concentration of bone imaging agents in functional asplenia

    SciTech Connect

    Dhekne, R.D.

    1981-07-01

    Three cases of sickle cell disease associated with functional asplenia are described. The spleen was not visualized on routine Tc-99m-sulfur colloid scan. The bone scan performed with Tc-99m-phosphate compounds revealed abnormal splenic activity in all three cases. The previous case reports and the literature on this subject are reviewed.

  4. Comparison of failure characteristics of a range of cancellous bone-bone cement composites.

    PubMed

    Lucksanasombool, P; Higgs, W A J; Ignat, M; Higgs, R J E D; Swain, M V

    2003-01-01

    Over the past decade, orthopedic surgery has embraced an increase in the depth of cement penetration into the adjacent cancellous bone structure. The resultant interdigitation transforms this zone into a thick layer of continuous interpenetrating composite material. The failure behavior of the composite formed with a number of potential bone cements with different bonding ability was investigated. The cancellous bone-cement composites exhibit considerable resistance to crack extension, and in situ optical observation indicates that the contribution of the cancellous bone is analogous to that of a typical fiber bridging process. The critical stress intensity factor and the work of fracture have been used to quantify the failure characteristics of the cancellous bone-cement composites. The nature of the crack propagation through these cement-bone composites was also captured via optical microscopy, and scanning electron microscopic images were taken of the failure surfaces. The R-curve behavior, or crack extension characteristic, of the cancellous bone-cement composite was also determined. The interesting outcome is that the cancellous bone-PMMA (poly-methylmethacrylate) composite, despite the absence of chemical bonding with bone, required the highest energy to fracture. In addition, the dimensional stability of the cement has a great effect on the interface.

  5. Allogenous bone grafts improved by bone marrow stem cells and platelet growth factors: clinical case reports.

    PubMed

    Filho Cerruti, Humberto; Kerkis, Irina; Kerkis, Alexandre; Tatsui, Nelson Hidekazu; da Costa Neves, Adriana; Bueno, Daniela Franco; da Silva, Marcelo Cavenaghi Pereira

    2007-04-01

    In order to increase the amount of available bone where dental implants must be placed, the present study has associated platelet-rich plasma (PRP) and mononuclear cells (MNCs) from bone marrow aspirate and bone scaffold (BS) in 32 patients aged between 45 and 75 years old. The MNC attainment and the adherence to the BS were confirmed through histology, cell culture, and scanning electron microscopy. The clinical results, analyzed by computed tomography, have showed that the scaffolds were well integrated and adapted to the cortical bone. We can conclude that the process of healing observed in the patients was due to the presence of mesenchymal stem cell in MNC fraction in the bone grafts.

  6. New laboratory tools in the assessment of bone quality.

    PubMed

    Chappard, D; Baslé, M F; Legrand, E; Audran, M

    2011-08-01

    Bone quality is a complex set of intricated and interdependent factors that influence bone strength. A number of methods have emerged to measure bone quality, taking into account the organic or the mineral phase of the bone matrix, in the laboratory. Bone quality is a complex set of different factors that are interdependent. The bone matrix organization can be described at five different levels of anatomical organization: nature (organic and mineral), texture (woven or lamellar), structure (osteons in the cortices and arch-like packets in trabecular bone), microarchitecture, and macroarchitecture. Any change in one of these levels can alter bone quality. An altered bone remodeling can affect bone quality by influencing one or more of these factors. We have reviewed here the main methods that can be used in the laboratory to explore bone quality on bone samples. Bone remodeling can be evaluated by histomorphometry; microarchitecture is explored in 2D on histological sections and in 3D by microCT or synchrotron. Microradiography and scanning electron microscopy in the backscattered electron mode can measure the mineral distribution; Raman and Fourier-transformed infra-red spectroscopy and imaging can simultaneously explore the organic and mineral phase of the matrix on multispectral images; scanning acoustic microscopy and nanoindentation provide biomechanical information on individual trabeculae. Finally, some histological methods (polarization, surface staining, fluorescence, osteocyte staining) may also be of interest in the understanding of quality as a component of bone fragility. A growing number of laboratory techniques are now available. Some of them have been described many years ago and can find a new youth; others having benefited from improvements in physical and computer techniques are now available.

  7. Ultrafast scanning probe microscopy

    DOEpatents

    Weiss, Shimon; Chemla, Daniel S.; Ogletree, D. Frank; Botkin, David

    1995-01-01

    An ultrafast scanning probe microscopy method for achieving subpicosecond-temporal resolution and submicron-spatial resolution of an observation sample. In one embodiment of the present claimed invention, a single short optical pulse is generated and is split into first and second pulses. One of the pulses is delayed using variable time delay means. The first pulse is then directed at an observation sample located proximate to the probe of a scanning probe microscope. The scanning probe microscope produces probe-sample signals indicative of the response of the probe to characteristics of the sample. The second pulse is used to modulate the probe of the scanning probe microscope. The time delay between the first and second pulses is then varied. The probe-sample response signal is recorded at each of the various time delays created between the first and second pulses. The probe-sample response signal is then plotted as a function of time delay to produce a cross-correlation of the probe sample response. In so doing, the present invention provides simultaneous subpicosecond-temporal resolution and submicron-spatial resolution of the sample.

  8. Teaching the SCANS Competencies.

    ERIC Educational Resources Information Center

    Department of Labor, Washington, DC. Secretary's Commission on Achieving Necessary Skills.

    SCANS (the Secretary's Commission on Achieving Necessary Skills) provides definitions of the knowledge students and workers need for workplace success and methods for applying these principles in communities throughout the United States. This document contains six articles that give education and training practitioners practical suggestions for…

  9. SCANS: The Missing Link.

    ERIC Educational Resources Information Center

    Price-Machado, Donna

    Three specific classroom techniques for teaching vocational English as a Second Language to adults are discussed. They are three items on the SCANS (Secretary's Commission on Achieving Necessary Skills) list of "easy things" to do to integrate workplace basics into the classroom, designed to encourage a student-focused classroom. They…

  10. The Organizational Scan.

    ERIC Educational Resources Information Center

    Tosti, Donald; Jackson, Stephanie D.

    1997-01-01

    Performance technologists like quick, cheap analysis that is rigorous and comprehensive. This article presents the organization scan model which makes successful compromises between the technologist's obligation to be rigorous and comprehensive and the sponsor's obligation to save money and time. Includes "Societal Bottom Line: Measurable…

  11. Gallbladder radionuclide scan

    MedlinePlus

    ... please enable JavaScript. Gallbladder radionuclide scan is a test that uses radioactive material to check gallbladder function. It is also used ... for bile duct blockage or leak. How the Test is Performed ... called a gamma emitting tracer into a vein. This material collects mostly in the liver. It will then ...

  12. Ultrafast scanning probe microscopy

    DOEpatents

    Weiss, S.; Chemla, D.S.; Ogletree, D.F.; Botkin, D.

    1995-05-16

    An ultrafast scanning probe microscopy method is described for achieving subpicosecond-temporal resolution and submicron-spatial resolution of an observation sample. In one embodiment of the present claimed invention, a single short optical pulse is generated and is split into first and second pulses. One of the pulses is delayed using variable time delay means. The first pulse is then directed at an observation sample located proximate to the probe of a scanning probe microscope. The scanning probe microscope produces probe-sample signals indicative of the response of the probe to characteristics of the sample. The second pulse is used to modulate the probe of the scanning probe microscope. The time delay between the first and second pulses is then varied. The probe-sample response signal is recorded at each of the various time delays created between the first and second pulses. The probe-sample response signal is then plotted as a function of time delay to produce a cross-correlation of the probe sample response. In so doing, the present invention provides simultaneous subpicosecond-temporal resolution and submicron-spatial resolution of the sample. 6 Figs.

  13. Factors affecting bone growth.

    PubMed

    Gkiatas, Ioannis; Lykissas, Marios; Kostas-Agnantis, Ioannis; Korompilias, Anastasios; Batistatou, Anna; Beris, Alexandros

    2015-02-01

    Bone growth and development are products of the complex interactions of genetic and environmental factors. Longitudinal bone growth depends on the growth plate. The growth plate has 5 different zones-each with a different functional role-and is the final target organ for longitudinal growth. Bone length is affected by several systemic, local, and mechanical factors. All these regulation systems control the final length of bones in a complicated way. Despite its significance to bone stability, bone growth in width has not been studied as extensively as longitudinal bone growth. Bone growth in width is also controlled by genetic factors, but mechanical loading regulates periosteal apposition. In this article, we review the most recent data regarding bone growth from the embryonic age and analyze the factors that control bone growth. An understanding of this complex system is important in identifying metabolic and developmental bone diseases and fracture risk.

  14. Primary bone marrow oedema syndromes.

    PubMed

    Patel, Sanjeev

    2014-05-01

    MRI scanning in patients with rheumatological conditions often shows bone marrow oedema, which can be secondary to inflammatory, degenerative, infective or malignant conditions but can also be primary. The latter condition is of uncertain aetiology and it is also uncertain whether it represents a stage in the progression to osteonecrosis in some patients. Patients with primary bone marrow oedema usually have lower limb pain, commonly the hip, knee, ankle or feet. The diagnosis is one of exclusion with the presence of typical MRI findings. Treatment is usually conservative and includes analgesics and staying off the affected limb. The natural history is that of gradual resolution of symptoms over a number of months. Evidence for medical treatment is limited, but open-label studies suggest bisphosphonates may help in the resolution of pain and improve radiological findings. Surgical decompression is usually used as a last resort.

  15. Automated, foot-bone registration using subdivision-embedded atlases for spatial mapping of bone mineral density.

    PubMed

    Liu, Lu; Commean, Paul K; Hildebolt, Charles; Sinacore, Dave; Prior, Fred; Carson, James P; Kakadiaris, Ioannis; Ju, Tao

    2013-06-01

    We present an atlas-based registration method for bones segmented from quantitative computed tomography (QCT) scans, with the goal of mapping their interior bone mineral densities (BMDs) volumetrically. We introduce a new type of deformable atlas, called subdivision-embedded atlas, which consists of a control grid represented as a tetrahedral subdivision mesh and a template bone surface embedded within the grid. Compared to a typical lattice-based deformation grid, the subdivision control grid possesses a relatively small degree of freedom tailored to the shape of the bone, which allows efficient fitting onto subjects. Compared with previous subdivision atlases, the novelty of our atlas lies in the addition of the embedded template surface, which further increases the accuracy of the fitting. Using this new atlas representation, we developed an efficient and fully automated pipeline for registering atlases of 12 tarsal and metatarsal bones to a segmented QCT scan of a human foot. Our evaluation shows that the mapping of BMD enabled by the registration is consistent for bones in repeated scans, and the regional BMD automatically computed from the mapping is not significantly different from expert annotations. The results suggest that our improved subdivision-based registration method is a reliable, efficient way to replace manual labor for measuring regional BMD in foot bones in QCT scans.

  16. Value of bone scintigraphy for detection and ageing of vertebral fractures in patients with severe osteoporosis and correlation between bone scintigraphy and mineral bone density.

    PubMed

    Kucukalic-Selimovic, Elma; Begic, Amela

    2004-01-01

    Osteoporosis is the most common of the metabolic bone diseases, and is an important cause of morbidity in the elderly. Bone scintigraphy is used to detect skeletal lesions at the earliest possible time, to monitor the course of the skeletal discase and to evaluate the metabolic activity of skeletal lesions. The aim of this study was to determine, by using the bone scan age of vertebral fractures in patients with severe osteoporosis, and make correlation between bone scintigraphy and mineral bone density. Material and methods 30 female patients were studied with bone scintigraphy after BMD.BMD was measurred with DEXA Hologic QDR 4500 Elite System. Correlation between T-score and uptake of radiofarmaceutical (Tc-99mMDP) was 0.849, and it was high. Intensity of uptake of Tc-99m MDP scintigraphy is an accurate method for the detection and ageing of fractures in osteoporotic patients.

  17. Cross-correlative 3D micro-structural investigation of human bone processed into bone allografts.

    PubMed

    Singh, Atul Kumar; Gajiwala, Astrid Lobo; Rai, Ratan Kumar; Khan, Mohd Parvez; Singh, Chandan; Barbhuyan, Tarun; Vijayalakshmi, S; Chattopadhyay, Naibedya; Sinha, Neeraj; Kumar, Ashutosh; Bellare, Jayesh R

    2016-05-01

    Bone allografts (BA) are a cost-effective and sustainable alternative in orthopedic practice as they provide a permanent solution for preserving skeletal architecture and function. Such BA however, must be processed to be disease free and immunologically safe as well as biologically and clinically useful. Here, we have demonstrated a processing protocol for bone allografts and investigated the micro-structural properties of bone collected from osteoporotic and normal human donor samples. In order to characterize BA at different microscopic levels, a combination of techniques such as Solid State Nuclear Magnetic Resonance (ssNMR), Scanning Electron Microscope (SEM), micro-computed tomography (μCT) and Thermal Gravimetric Analysis (TGA) were used for delineating the ultra-structural property of bone. ssNMR revealed the extent of water, collagen fine structure and crystalline order in the bone. These were greatly perturbed in the bone taken from osteoporotic bone donor. Among the processing methods analyzed, pasteurization at 60 °C and radiation treatment appeared to substantially alter the bone integrity. SEM study showed a reduction in Ca/P ratio and non-uniform distribution of elements in osteoporotic bones. μ-CT and MIMICS (Materialize Interactive Medical Image Control System) demonstrated that pasteurization and radiation treatment affects the BA morphology and cause a shift in the HU unit. However, the combination of all these processes restored all-important parameters that are critical for BA integrity and sustainability. Cross-correlation between the various probes we used quantitatively demonstrated differences in morphological and micro-structural properties between BA taken from normal and osteoporotic human donor. Such details could also be instrumental in designing an appropriate bone scaffold. For the best restoration of bone microstructure and to be used as a biomaterial allograft, a step-wise processing method is recommended that preserves all

  18. Bone Marrow Diseases

    MedlinePlus

    Bone marrow is the spongy tissue inside some of your bones, such as your hip and thigh bones. It contains stem cells. The stem cells can ... the platelets that help with blood clotting. With bone marrow disease, there are problems with the stem ...

  19. Metastatic Bone Disease

    MedlinePlus

    ... secrete factors that interact with the naturally occurring cells in the bone and cause bone destruction, new bone formation, or both. Effects Because MBD weakens the affected bones, people with the disease are prone to fractures. Broken ...

  20. Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies

    NASA Astrophysics Data System (ADS)

    Welch, D.; Harken, A. D.; Randers-Pehrson, G.; Brenner, D. J.

    2015-05-01

    We present the complete construction methodology for an anatomically accurate mouse phantom made using materials which mimic the characteristics of tissue, lung, and bone for radiation dosimetry studies. Phantoms were constructed using 2 mm thick slices of tissue equivalent material which was precision machined to clear regions for insertion of lung and bone equivalent material where appropriate. Images obtained using a 3D computed tomography (CT) scan clearly indicate regions of tissue, lung, and bone that match their position within the original mouse CT scan. Additionally, radiographic films are used with the phantom to demonstrate dose mapping capabilities. The construction methodology presented here can be quickly and easily adapted to create a phantom of any specific small animal given a segmented CT scan of the animal. These physical phantoms are a useful tool to examine individual organ dose and dosimetry within mouse systems that are complicated by density inhomogeneity due to bone and lung regions.

  1. Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.

    PubMed

    Welch, D; Harken, A D; Randers-Pehrson, G; Brenner, D J

    2015-05-07

    We present the complete construction methodology for an anatomically accurate mouse phantom made using materials which mimic the characteristics of tissue, lung, and bone for radiation dosimetry studies. Phantoms were constructed using 2 mm thick slices of tissue equivalent material which was precision machined to clear regions for insertion of lung and bone equivalent material where appropriate. Images obtained using a 3D computed tomography (CT) scan clearly indicate regions of tissue, lung, and bone that match their position within the original mouse CT scan. Additionally, radiographic films are used with the phantom to demonstrate dose mapping capabilities. The construction methodology presented here can be quickly and easily adapted to create a phantom of any specific small animal given a segmented CT scan of the animal. These physical phantoms are a useful tool to examine individual organ dose and dosimetry within mouse systems that are complicated by density inhomogeneity due to bone and lung regions.

  2. Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies

    PubMed Central

    Welch, D; Harken, A D; Randers-Pehrson, G; Brenner, D J

    2015-01-01

    We present the complete construction methodology for an anatomically accurate mouse phantom made using materials which mimic the characteristics of tissue, lung, and bone for radiation dosimetry studies. Phantoms were constructed using 2 mm thick slices of tissue equivalent material which was precision machined to clear regions for insertion of lung and bone equivalent material where appropriate. Images obtained using a 3D computed tomography (CT) scan clearly indicate regions of tissue, lung, and bone that match their position within the original mouse CT scan. Additionally, radiographic films are used with the phantom to demonstrate dose mapping capabilities. The construction methodology presented here can be quickly and easily adapted to create a phantom of any specific small animal given a segmented CT scan of the animal. These physical phantoms are a useful tool to examine individual organ dose and dosimetry within mouse systems that are complicated by density inhomogeneity due to bone and lung regions. PMID:25860401

  3. Optical scanning holographic microscopy

    NASA Astrophysics Data System (ADS)

    Poon, Ting-Chung; Doh, Kyu B.; Schilling, Bradley W.; Wu, Ming H.; Shinoda, Kazunori K.; Suzuki, Yoshiji

    1995-03-01

    We first review a newly developed 3D imaging technique called optical scanning holography (OSH), and discuss recording and reconstruction of a point object using the principle of OSH. We then derive 3D holographic magnification, using three points configured as a 3D object. Finally, we demonstrated 3D imaging capability of OSH by holographically recording two planar objects at different depths and reconstructing the hologram digitally.

  4. Fly-scan ptychography

    DOE PAGES

    Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.; ...

    2015-03-13

    We report an experimental ptychography measurement performed in fly-scan mode. With a visible-light laser source, we demonstrate a 5-fold reduction of data acquisition time. By including multiple mutually incoherent modes into the incident illumination, high quality images were successfully reconstructed from blurry diffraction patterns. This approach significantly increases the throughput of ptychography, especially for three-dimensional applications and the visualization of dynamic systems.

  5. Scanning micro-sclerometer

    DOEpatents

    Oliver, Warren C.; Blau, Peter J.

    1994-01-01

    A scanning micro-sclerometer measures changes in contact stiffness and correlates these changes to characteristics of a scratch. A known force is applied to a contact junction between two bodies and a technique employing an oscillating force is used to generate the contact stiffness between the two bodies. As the two bodies slide relative to each other, the contact stiffness changes. The change is measured to characterize the scratch.

  6. Scanning micro-sclerometer

    DOEpatents

    Oliver, W.C.; Blau, P.J.

    1994-11-01

    A scanning micro-sclerometer measures changes in contact stiffness and correlates these changes to characteristics of a scratch. A known force is applied to a contact junction between two bodies and a technique employing an oscillating force is used to generate the contact stiffness between the two bodies. As the two bodies slide relative to each other, the contact stiffness changes. The change is measured to characterize the scratch. 2 figs.

  7. Bone Health and Osteoporosis.

    PubMed

    Lupsa, Beatrice C; Insogna, Karl

    2015-09-01

    Osteoporosis is characterized by low bone mass and microarchitectural deterioration of bone tissue leading to decreased bone strength and an increased risk of low-energy fractures. Central dual-energy X-ray absorptiometry measurements are the gold standard for determining bone mineral density. Bone loss is an inevitable consequence of the decrease in estrogen levels during and following menopause, but additional risk factors for bone loss can also contribute to osteoporosis in older women. A well-balanced diet, exercise, and smoking cessation are key to maintaining bone health as women age. Pharmacologic agents should be recommended in patients at high risk for fracture.

  8. Forensic Scanning Electron Microscope

    NASA Astrophysics Data System (ADS)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  9. Scanning ultrafast electron microscopy.

    PubMed

    Yang, Ding-Shyue; Mohammed, Omar F; Zewail, Ahmed H

    2010-08-24

    Progress has been made in the development of four-dimensional ultrafast electron microscopy, which enables space-time imaging of structural dynamics in the condensed phase. In ultrafast electron microscopy, the electrons are accelerated, typically to 200 keV, and the microscope operates in the transmission mode. Here, we report the development of scanning ultrafast electron microscopy using a field-emission-source configuration. Scanning of pulses is made in the single-electron mode, for which the pulse contains at most one or a few electrons, thus achieving imaging without the space-charge effect between electrons, and still in ten(s) of seconds. For imaging, the secondary electrons from surface structures are detected, as demonstrated here for material surfaces and biological specimens. By recording backscattered electrons, diffraction patterns from single crystals were also obtained. Scanning pulsed-electron microscopy with the acquired spatiotemporal resolutions, and its efficient heat-dissipation feature, is now poised to provide in situ 4D imaging and with environmental capability.

  10. [Imaging of bone metastases].

    PubMed

    Amoretti, Nicolas; Thariat, Juliette; Nouri, Yasir; Foti, Pauline; Hericord, Olivier; Stolear, Sandy; Coco, Lucia; Hauger, Olivier; Huwart, Laurent; Boileau, Pascal

    2013-11-01

    Bone metastases are detected at initial diagnosis of cancer in 25% of cases and bone metastases are common in the course of a majority of cancer types. The spine and proximal long bones are the most affected sites. Knowledge of the basic radiological semiology is important to make the proper diagnosis of metastasis(s) bone(s), especially in situations in which the clinical context is not suggestive of metastases (such as cases where bone metastases are inaugural or cases of peripheral solitary metastasis). Tumor aggressiveness can be assessed at the level of the cortical bone and periosteum. Lodwick criteria are useful for the diagnosis of malignancy and tumor aggressiveness at initial diagnosis on plain radiographs, which are very important in the context of bone metastases. A CT scanner is required to confirm the malignancy of a bone lesion. MRI is complementary to the scanner including for the assessment of bone marrow involvement and tumor extensions.

  11. Advances in noninvasive bone measurement

    SciTech Connect

    Mazess, R.B.; Barden, H.; Vetter, J.; Ettinger, M.

    1989-01-01

    Several noninvasive measurement methods are used for evaluation of metabolic disease. Single-photon (/sup 125/I) scans of the peripheral skeleton are useful in some diseases but are ineffective in osteoporosis (even on the distal radius or os calcis) because they cannot predict spinal or femoral density. Also, peripheral measurements show high percentages of false negatives, that is many patients with fractures have normal peripheral density. Dual-photon (/sup 153/Gd) scans of the spine, femur, and total skeleton are precise and accurate (2% error) and provide direct measurements of bone strength at fracture sites. This gives the best discrimination of abnormality and the most sensitive monitoring. Quantitative computed computed tomography (QCT) allows measurement of the spine but not the critical proximal femur area. QCT has a large accuracy error because (a) the limited area measured (under 5 cm3) fails to represent the total vertebral body, (b) technical errors, and (c) variable fat and osteoid influence the results. 25 references.

  12. Topography of acoustical properties of long bones: from biomechanical studies to bone health assessment.

    PubMed

    Tatarinov, Alexey; Sarvazyan, Armen

    2008-01-01

    The article presents a retrospective view on the assessment of long bones condition using topographical patterns of the acoustic properties. The application of ultrasonic point-contact transducers with exponential waveguides on a short acoustic base for detailed measurements in human long bones by the surface transmission was initiated during the 1980s in Latvia. The guided wave velocity was mapped on the surface of the long bones and the topographical patterns reflected the biomechanical peculiarities. Axial velocity profiles obtained in vivo by measurements along the medial surface of tibia varied due to aging, hypokinesia, and physical training. The method has been advanced at Artann Laboratories (West Trenton, NJ) by the introduction of multifrequency data acquisition and axial scanning. The model studies carried out on synthetic phantoms and in bone specimens confirmed the potential to evaluate separately changes of the bone material properties and of the cortical thickness by multifrequency acoustic measurements at the 0.1 to 1 MHz band. The bone ultrasonic scanner (BUSS) is an axial mode ultrasonometer developed to depict the acoustic profile of bone that will detect the onset of bone atrophy as a spatial process. Clinical trials demonstrated a high sensitivity of BUSS to osteoporosis and the capability to assess early stage of osteopenia.

  13. Topography of Acoustical Properties of Long Bones: From Biomechanical Studies to Bone Health Assessment

    PubMed Central

    Tatarinov, Alexey; Sarvazyan, Armen

    2010-01-01

    The article presents a retrospective view on the assessment of long bones condition using topographical patterns of the acoustic properties. The application of ultrasonic point-contact transducers with exponential waveguides on a short acoustic base for detailed measurements in human long bones by the surface transmission was initiated during the 1980s in Latvia. The guided wave velocity was mapped on the surface of the long bones and the topographical patterns reflected the biomechanical peculiarities. Axial velocity profiles obtained in vivo by measurements along the medial surface of tibia varied due to aging, hypokinesia, and physical training. The method has been advanced at Artann Laboratories (West Trenton, NJ) by the introduction of multifrequency data acquisition and axial scanning. The model studies carried out on synthetic phantoms and in bone specimens confirmed the potential to evaluate separately changes of the bone material properties and of the cortical thickness by multifrequency acoustic measurements at the 0.1 to 1 MHz band. The bone ultrasonic scanner (BUSS) is an axial mode ultrasonometer developed to depict the acoustic profile of bone that will detect the onset of bone atrophy as a spatial process. Clinical trials demonstrated a high sensitivity of BUSS to osteoporosis and the capability to assess early stage of osteopenia. PMID:18599416

  14. [Bone involvement in endocrinopathies].

    PubMed

    Ribot, C; Trémollières, F; Pouillès, J M

    1994-06-04

    Progress in bone densitometry, particularly biphotonic absoptiometry, has made it possible to better identify the effects of endocrinopathies on bone. Both cortical and trabecular bone structures can be evaluated quantitatively and topographically revealing important information on the pathophysiology of bone loss. Sex hormones play a major role in the regulation of bone mineralization and hypogonadism, whatever the origin, can lead to deleterious effects. Bone loss is known to be significative in high performance female athletes with amenorrhoea; long-term consequences are not yet determined, but stress fractures have been reported in up to 50%. Other hypogonadisms leading to bone demineralization include anorexia nervosa, chronic intake of gonadotrophin releasing hormone analogues and anti-oestrogens, and hyperprolactinism. Hyperthyroidism leads to a negative calcium balance and demineralization with remodelling, predominantly in cortical bone. In hypothyroid states a 10% bone loss is observed in vertebrae. In both cases, bone densitometry should be performed in order to evaluate the effect of treatment. The deleterious effect of spontaneous or iatrogenic hypercortisism is well known, leading to spontaneous wedge fractures of the vertebrae due to predominating trabecular bone loss. The mechanism of action of corticosteroids on bone metabolism is complex, but the major effect is an inhibition of osteoblast maturation. Recovery may be possible, but no large long-term series have yet been reported. Hyperparathyroidism and acromegaly also affect bone mineralization. The information provided by bone densitometry is essential to properly manage patients with endocrinopathies affecting bone mineralization.

  15. Infant formula promotes bone growth in neonatal piglets by enhancing osteoblastogenesis through bone morphogenic protein signaling

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Relatively few studies have examined the effects of formula feeding relative to breast-feeding on bone in the neonate. Using peripheral quantitative CT scan and histomorphometric analysis, we demonstrated that neonatal piglets fed with soy-based formula (SF) and cow milk-based formula (MF) for 21 or...

  16. The effect of autologous bone marrow stromal cells differentiated on scaffolds for canine tibial bone reconstruction.

    PubMed

    Özdal-Kurt, F; Tuğlu, I; Vatansever, H S; Tong, S; Deliloğlu-Gürhan, S I

    2015-01-01

    Bone marrow contains mesenchymal stem cells that form many tissues. Various scaffolds are available for bone reconstruction by tissue engineering. Osteoblastic differentiated bone marrow stromal cells (BMSC) promote osteogenesis on scaffolds and stimulate bone regeneration. We investigated the use of cultured autologous BMSC on different scaffolds for healing defects in tibias of adult male canines. BMSC were isolated from canine humerus bone marrow, differentiated into osteoblasts in culture and loaded onto porous ceramic scaffolds including hydroxyapatite 1, hydroxyapatite gel and calcium phosphate. Osteoblast differentiation was verified by osteonectine and osteocalcine immunocytochemistry. The scaffolds with stromal cells were implanted in the tibial defect. Scaffolds without stromal cells were used as controls. Sections from the defects were processed for histological, ultrastructural, immunohistochemical and histomorphometric analyses to analyze the healing of the defects. BMSC were spread, allowed to proliferate and differentiate to osteoblasts as shown by alizarin red histochemistry, and osteocalcine and osteonectine immunostaining. Scanning electron microscopy showed that BMSC on the scaffolds were more active and adhesive to the calcium phosphate scaffold compared to the others. Macroscopic bone formation was observed in all groups, but scaffolds with stromal cells produced significantly better results. Bone healing occurred earlier and faster with stromal cells on the calcium phosphate scaffold and produced more callus compared to other scaffolds. Tissue healing and osteoblastic marker expression also were better with stromal cells on the scaffolds. Increased trabecula formation, cell density and decreased fibrosis were observed in the calcium phosphate scaffold with stromal cells. Autologous cultured stromal cells on the scaffolds were useful for healing of canine tibial bone defects. The calcium phosphate scaffold was the best for both cell

  17. Bone marrow blood vessel ossification and "microvascular dead space" in rat and human long bone.

    PubMed

    Prisby, Rhonda D

    2014-07-01

    Severe calcification of the bone microvascular network was observed in rats, whereby the bone marrow blood vessels appeared ossified. This study sought to characterize the magnitude of ossification in relation to patent blood vessels and adipocyte content in femoral diaphyses. Additionally, this study confirmed the presence of ossified vessels in patients with arteriosclerotic vascular disease and peripheral vascular disease and cellulitis. Young (4-6 month; n=8) and old (22-24 month; n=8) male Fischer-344 rats were perfused with barium sulfate to visualize patent bone marrow blood vessels. Femoral shafts were processed for bone histomorphometry to quantify ossified (Goldner's Trichrome) and calcified (Alizarin Red) vessels. Adipocyte content was also determined. Additional femora (n=5/age group) were scanned via μCT to quantify microvascular ossification. Bone marrow blood vessels from the rats and the human patients were also isolated and examined via microscopy. Ossified vessels (rats and humans) had osteocyte lacunae on the vessel surfaces and "normal" vessels were transitioning into bone. The volume of ossified vessels was 4800% higher (p<0.05) in the old vs. young rats. Calcified and ossified vessel volumes per tissue volume and calcified vessel volume per patent vessel volume were augmented (p<0.05) 262%, 375% and 263%, respectively, in the old vs. young rats. Ossified and patent vessel number was higher (171%) and lower (40%), respectively, in the old vs. young rats. Finally, adipocyte volume per patent vessel volume was higher (86%) with age. This study is the first to report ossification of bone marrow blood vessels in rats and humans. Ossification presumably results in "microvascular dead space" in regard to loss of patency and vasomotor function as opposed to necrosis. Progression of bone microvascular ossification may provide the common link associated with age-related changes in bone and bone marrow. The clinical implications may be evident in the

  18. Bioreactor cultivation of anatomically shaped human bone grafts.

    PubMed

    Temple, Joshua P; Yeager, Keith; Bhumiratana, Sarindr; Vunjak-Novakovic, Gordana; Grayson, Warren L

    2014-01-01

    In this chapter, we describe a method for engineering bone grafts in vitro with the specific geometry of the temporomandibular joint (TMJ) condyle. The anatomical geometry of the bone grafts was segmented from computed tomography (CT) scans, converted to G-code, and used to machine decellularized trabecular bone scaffolds into the identical shape of the condyle. These scaffolds were seeded with human bone marrow-derived mesenchymal stem cells (MSCs) using spinner flasks and cultivated for up to 5 weeks in vitro using a custom-designed perfusion bioreactor system. The flow patterns through the complex geometry were modeled using the FloWorks module of SolidWorks to optimize bioreactor design. The perfused scaffolds exhibited significantly higher cellular content, better matrix production, and increased bone mineral deposition relative to non-perfused (static) controls after 5 weeks of in vitro cultivation. This technology is broadly applicable for creating patient-specific bone grafts of varying shapes and sizes.

  19. Bone Texture Characterization for Osteoporosis Diagnosis using Digital Radiography

    PubMed Central

    Zheng, Keni; Makrogiannis, Sokratis

    2017-01-01

    We introduce texture classification techniques to effectively diagnose osteoporosis in bone radiography data. Osteoporosis is an age-related systemic bone skeletal disorder characterized by low bone mass and bone structure deterioriation that results in increased bone fragility and higher fracture risk. Therefore, early diagnosis can effectively predict fracture risk and prevent the disease. Automated diagnosis from digital radiographs is very challenging since the scans of healthy and osteoporotic subjects show little or no visual differences, and their density histograms mostly overlap. We designed a system to separate healthy from osteoporotic subjects using high-dimensional textural feature representations computed from radiographs. These features were then reduced using feature selection to obtain the more discriminant subset that was finally classified by our methods. The top performing approach yields 79.3% accuracy and 81% area under the ROC over 116 bone radiographs. PMID:28268501

  20. Scanning radiographic apparatus

    SciTech Connect

    Albert, R.D.

    1980-04-01

    Visual display of dental, medical or other radiographic images is realized with an x-ray tube in which an electron beam is scanned through an x-y raster pattern on a broad anode plate, the scanning being synchronized with the x-y sweep signals of a cathode ray tube display and the intensity signal for the display being derived from a small x-ray detector which receives x-rays that have passed through the subject to be imaged. Positioning and support of the detector are provided for by disposing the detector in a probe which may be attached to the x-ray tube at any of a plurality of different locations and by providing a plurality of such probes of different configuration in order to change focal length, to accommodate to different detector placements relative to the subject, to enhance patient comfort and to enable production of both periapical images and wider angle pantomographic images. High image definition with reduced radiation dosage is provided for by a lead glass collimator situated between the x-ray tube and subject and having a large number of spaced-apart minute radiation transmissive passages convergent on the position of the detector. Releasable mounting means enable changes of collimator in conjunction with changes of the probe to change focal length. A control circuit modifies the x-y sweep signals applied to the x-ray tube and modulates electron beam energy and current in order to correct for image distortions and other undesirable effects which can otherwise be present in a scanning x-ray system.

  1. Congenital malformations of the temporal bone.

    PubMed

    Mukerji, Shraddha S; Parmar, Hemant A; Ibrahim, Mohannad; Mukherji, Suresh K

    2011-08-01

    Congenital ear or temporal bone malformations are a diagnostic challenge to radiologists and surgeons alike. Newer imaging techniques can detect subtle changes in middle ear and cochlear anatomy. This information is invaluable with increasing use of hearing restoration surgeries and/or cochlear implants in such patients. This article discusses the embryogenesis, classification system, and salient imaging findings of congenital outer, middle ear, and inner ear anomalies in children. Both high-resolution computerized tomography and magnetic resonance imaging scans of the temporal bones are described.

  2. Controlled Scanning Probe Lithography

    NASA Astrophysics Data System (ADS)

    Ruskell, Todd G.; Sarid, Dror; Workman, Richard K.; Pyle, Jason L.

    1997-03-01

    A method for real-time monitoring of the quality and quantity of silicon oxide grown on silicon using conducting-tip scanning probe lithography has been developed. The sub-picoampere tip-sample currents measured during lithography in ambient conditions are shown to be proportional to the amount of silicon oxide being grown. In addition, we have demonstrated the ability to control the composition of the grown material by altering the lithographic environment. Silicon nitride growth is shown to result from lithography on silicon samples in an environment of annhydrous ammonia.

  3. Battery scanning system

    SciTech Connect

    Dieu, L.F.

    1984-11-20

    A battery scanning system which is capable of monitoring and displaying the voltage of each cell in a battery or upon command provides the cell voltage distribution by displaying the cell number and voltage value of highest and lowest cell. The system has a digital logic system, display, input switches for operator generated variables, an alarm, relays, relay selection gates, an optically coupled isolation amplifier, power source and an analog-digital converter. The optically coupled analog amplifier electrically isolates the system from the battery so that large voltage offsets will not adversely affect the automatic measuring of the cells.

  4. Scanning Quantum Dot Microscopy

    NASA Astrophysics Data System (ADS)

    Wagner, Christian; Green, Matthew F. B.; Leinen, Philipp; Deilmann, Thorsten; Krüger, Peter; Rohlfing, Michael; Temirov, Ruslan; Tautz, F. Stefan

    2015-07-01

    We introduce a scanning probe technique that enables three-dimensional imaging of local electrostatic potential fields with subnanometer resolution. Registering single electron charging events of a molecular quantum dot attached to the tip of an atomic force microscope operated at 5 K, equipped with a qPlus tuning fork, we image the quadrupole field of a single molecule. To demonstrate quantitative measurements, we investigate the dipole field of a single metal adatom adsorbed on a metal surface. We show that because of its high sensitivity the technique can probe electrostatic potentials at large distances from their sources, which should allow for the imaging of samples with increased surface roughness.

  5. Real Scan Evolution.

    DTIC Science & Technology

    1982-02-01

    Computer Image Generation Visual Simulation Computer Graphics Al gortthm Geometric Model tng 1%ABSTRACT (C.tla. -mm. .00n ad N ue-e""V ONd Ofmi* OF 61"knsee...envtronments. modeled as a single valued el evatYo fnction of horizontal location. The objecttve of the development was to analyze the feasibility of a real...generator capable of creating complex Imagery .in real time? Is the solution amenable to efficient off-lne modeling of complex environments? The Real Scan

  6. OSTEOBLAST ADHESION OF BREAST CANCER CELLS WITH SCANNING ACOUSTIC MICROSCOPY

    SciTech Connect

    Chiaki Miyasaka; Robyn R. Mercer; Andrea M. Mastro; Ken L. Telschow

    2005-03-01

    Breast cancer frequently metastasizes to the bone. Upon colonizing bone tissue, the cancer cells stimulate osteoclasts (cells that break bone down), resulting in large lesions in the bone. The breast cancer cells also affect osteoblasts (cells that build new bone). Conditioned medium was collected from a bone-metastatic breast cancer cell line, MDA-MB-231, and cultured with an immature osteoblast cell line, MC3T3-E1. Under these conditions the osteoblasts acquired a changed morphology and appeared to adherer in a different way to the substrate and to each other. To characterize cell adhesion, MC3T3-E1 osteoblasts were cultured with or without MDA-MB-231 conditioned medium for two days, and then assayed with a mechanical scanning acoustic reflection microscope (SAM). The SAM indicated that in normal medium the MC3T3-E1 osteoblasts were firmly attached to their plastic substrate. However, MC3T3-E1 cells cultured with MDA-MB-231 conditioned medium displayed both an abnormal shape and poor adhesion at the substrate interface. The cells were fixed and stained to visualize cytoskeletal components using optical microscopic techniques. We were not able to observe these differences until the cells were quite confluent after 7 days of culture. However, using the SAM, we were able to detect these changes within 2 days of culture with MDA-MB-231 conditioned medium

  7. Factors stimulating bone formation.

    PubMed

    Lind, M; Bünger, C

    2001-10-01

    The aim of this review is to describe major approaches for stimulating bone healing and to review other factors affecting bone healing. Spinal bone fusion after surgery is a demanding process requiring optimal conditions for clinical success. Bone formation and healing can be enhanced through various methods. Experimental studies have revealed an array of stimulative measures. These include biochemical stimulation by use of hormones and growth factors, physical stimulation through mechanical and electromagnetic measures, and bone grafting by use of bone tissue or bone substitutes. Newer biological techniques such as stem cell transplantation and gene therapy can also be used to stimulate bone healing. Apart from bone transplantation, clinical experience with the many stimulation modalities is limited. Possible areas for clinical use of these novel methods are discussed.

  8. Regulation of Bone Metabolism

    PubMed Central

    Shahi, Maryam; Peymani, Amir; Sahmani, Mehdi

    2017-01-01

    Bone is formed through the processes of endochondral and intramembranous ossification. In endochondral ossification primary mesenchymal cells differentiate to chondrocytes and then are progressively substituted by bone, while in intramembranous ossification mesenchymal stem cells (MSCs) differentiate directly into osteoblasts to form bone. The steps of osteogenic proliferation, differentiation, and bone homeostasis are controlled by various markers and signaling pathways. Bone needs to be remodeled to maintain integrity with osteoblasts, which are bone-forming cells, and osteoclasts, which are bone-degrading cells.In this review we considered the major factors and signaling pathways in bone formation; these include fibroblast growth factors (FGFs), bone morphogenetic proteins (BMPs), wingless-type (Wnt) genes, runt-related transcription factor 2 (RUNX2) and osteoblast-specific transcription factor (osterix or OSX). PMID:28367467

  9. Bisphosphonates and bone quality

    PubMed Central

    Pazianas, Michael; van der Geest, Stefan; Miller, Paul

    2014-01-01

    Bisphosphonates (BPs) are bone-avid compounds used as first-line medications for the prevention and treatment of osteoporosis. They are also used in other skeletal pathologies such as Paget's and metastatic bone disease. They effectively reduce osteoclast viability and also activity in the resorptive phase of bone remodelling and help preserve bone micro-architecture, both major determinants of bone strength and ultimately of the susceptibility to fractures. The chemically distinctive structure of each BP used in the clinic determines their unique affinity, distribution/penetration throughout the bone and their individual effects on bone geometry, micro-architecture and composition or what we call ‘bone quality'. BPs have no clinically significant anabolic effects. This review will touch upon some of the components of bone quality that could be affected by the administration of BPs. PMID:24876930

  10. [Microdestruction of the bone].

    PubMed

    Iankovskiĭ, V É

    2014-01-01

    The objective of the present study was the detection of microcracks in the compact bone tissue surrounding the fracture and in deformed bone undergoing subcritical loading. The portions of deformed bone tissue and terminal fragments of broken bones were obtained in the form of blocks longitudinally sawcut from the regions of primary and secondary bone rupture. A total of 300 such blocks were available for the examination. All portions of the deformed bone tissue and terminal fragments of broken bones showed up microcracks commensurate with the bone structures. They were actually hardened traces of deformation that preceded the fracture and reflected the volume of the destroyed bone tissue; moreover, in certain cases they allowed to identify the kind of the object that exerted the external action (either a blow or slow bending).

  11. Regulation of Bone Metabolism.

    PubMed

    Shahi, Maryam; Peymani, Amir; Sahmani, Mehdi

    2017-04-01

    Bone is formed through the processes of endochondral and intramembranous ossification. In endochondral ossification primary mesenchymal cells differentiate to chondrocytes and then are progressively substituted by bone, while in intramembranous ossification mesenchymal stem cells (MSCs) differentiate directly into osteoblasts to form bone. The steps of osteogenic proliferation, differentiation, and bone homeostasis are controlled by various markers and signaling pathways. Bone needs to be remodeled to maintain integrity with osteoblasts, which are bone-forming cells, and osteoclasts, which are bone-degrading cells.In this review we considered the major factors and signaling pathways in bone formation; these include fibroblast growth factors (FGFs), bone morphogenetic proteins (BMPs), wingless-type (Wnt) genes, runt-related transcription factor 2 (RUNX2) and osteoblast-specific transcription factor (osterix or OSX).

  12. Scans Solo: A One-Person Environmental Scanning Process.

    ERIC Educational Resources Information Center

    Clagett, Craig A.

    An effective environmental scan will improve the quality of community college planning and decision making by alerting institutional leaders to the challenges and opportunities in the environment. Scanning can be done in three ways: (1) establishing a scanning committee to gather and synthesize information to guide planning; (2) sponsoring a…

  13. VEGF inhibition as possible therapy in spondyloarthritis patients: Targeting bone remodelling.

    PubMed

    Lacout, Alexis; Carlier, Robert Yves; El Hajjam, Mostafa; Marcy, Pierre Yves

    2017-04-01

    Spondyloarthritis refers to a group of chronic inflammatory rheumatic diseases that predominantly affects the axial skeleton, causing pain and stiffness. Human bone is highly dynamic organ that interacts with a wide array cells and tissues. Process of bone remodelling relies on a delicate balance between bone formation and bone resorption, orchestrated by osteoblasts and osteoclasts. Disruption of this homeostatic balance of bone removal and replacement can manifest as inappropriate new bone formation found in spondylarthritis. We hypothesize that VEGF may promote bone remodelling, stimulate angiogenesis, and both osteoclastic and osteoblastic activity. Anti VEGF may be tested as a dedicated therapy to prevent bone remodelling in spondyloarthritis patients, namely in cases of aggressive disease. Bone remodelling could be monitored by using [18F]Fluoride PET scan.

  14. Bone-immune cell crosstalk: bone diseases.

    PubMed

    Mori, Giorgio; D'Amelio, Patrizia; Faccio, Roberta; Brunetti, Giacomina

    2015-01-01

    Bone diseases are associated with great morbidity; thus, the understanding of the mechanisms leading to their development represents a great challenge to improve bone health. Recent reports suggest that a large number of molecules produced by immune cells affect bone cell activity. However, the mechanisms are incompletely understood. This review aims to shed new lights into the mechanisms of bone diseases involving immune cells. In particular, we focused our attention on the major pathogenic mechanism underlying periodontal disease, psoriatic arthritis, postmenopausal osteoporosis, glucocorticoid-induced osteoporosis, metastatic solid tumors, and multiple myeloma.

  15. Free motion scanning system

    DOEpatents

    Sword, Charles K.

    2000-01-01

    The present invention relates to an ultrasonic scanner system and method for the imaging of a part system, the scanner comprising: a probe assembly spaced apart from the surface of the part including at least two tracking signals for emitting radiation and a transmitter for emitting ultrasonic waves onto a surface in order to induce at least a portion of the waves to be reflected from the part, at least one detector for receiving the radiation wherein the detector is positioned to receive the radiation from the tracking signals, an analyzer for recognizing a three-dimensional location of the tracking signals based on the emitted radiation, a differential converter for generating an output signal representative of the waveform of the reflected waves, and a device such as a computer for relating said tracking signal location with the output signal and projecting an image of the resulting data. The scanner and method are particularly useful to acquire ultrasonic inspection data by scanning the probe over a complex part surface in an arbitrary scanning pattern.

  16. Ultrafast scanning tunneling microscopy

    SciTech Connect

    Botkin, D.A. |

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  17. Study on the Formation and Precipitation Mechanism of Mn5Si3 Phase in the MBA-2 Brass Alloy

    NASA Astrophysics Data System (ADS)

    Li, Hang; Jie, Jinchuan; Zhang, Pengchao; Jia, Chunxu; Wang, Tongmin; Li, Tingju

    2016-06-01

    Mn5Si3 is an attractive dispersion in the special brass, owing to its high hardness and high wear resistance. In the present study, synchrotron X-ray radiography and rapid cooling were applied to investigate the formation mechanism of Mn5Si3 phase in the MBA-2 brass alloy. The primary Mn5Si3 phase is proved to exist stably in the alloy melt and nucleate from the melt at temperatures above 1373 K (1100 °C). In addition, the precipitation mechanism of Mn5Si3 phase is addressed systematically by the isothermal heat treatment. The Mn5Si3 particles are observed to precipitate from the matrix at temperatures above 1023 K (750 °C), and a crystallographic orientation relationship is found between the precipitated Mn5Si3 particle and β phase: (110)_{β } //(1overline{1} 00)_{{{{Mn}}5 {{Si}}3 }} and [overline{1} 11]_{β } //[11overline{2} overline{2} ]_{{{{Mn}}5 {{Si}}3 }} . However, the precipitation of Mn5Si3 phase is thermodynamically inhibited at lower temperatures, which can be ascribed to the increase in the Gibbs free energy of formation of Mn5Si3 with decreasing the temperature.

  18. Light and scanning electron microscopic report of four fractured implants.

    PubMed

    Piattelli, A; Piattelli, M; Scarano, A; Montesani, L

    1998-01-01

    Although they are fortunately rare, implant fractures can cause significant problems for both clinicians and patients. The authors present a light and scanning electron microscopic study of four fractured implants in two patients. Both patients had parafunctional habits (bruxism), hypertrophic masticatory muscles, and wear of occlusal surfaces. The scanning electron microscopic study of the fractured surfaces of all four implants showed the presence of fatigue striations. Bending overload was probably created by a combination of parafunctional forces, bone resorption, posterior location of the implants, and implant diameter.

  19. [State of the art in nuclear imaging for the diagnosis of bone metastases].

    PubMed

    Ouvrier, Matthieu-John; Vignot, Stéphane; Thariat, Juliette

    2013-11-01

    Cancers prone to spread to bone include prostate, lung, kidney, breast and thyroid cancers. While bone scanner has been widely used in the past decades, PET-based imaging modalities are increasingly used. Current modalities of PET imaging of bone metastases include tumor and inflammatory targeting with FDG-PET, bone imaging with NaF-PET, and direct cancer-specific markers such as FDOPA-PET or PET using choline. The cancer-specific metastatic patterns and the relative prognosis conferred by osseous metastases (versus visceral metastases) may determine the need for bone scan, FDG-PET for the detection of bone metastases. Because some cancers have a mixed skeletal and visceral, cocktails PET radiopharmaceuticals may also be discussed in the future. The cancer-specific context and performances of bone scan and PET imaging are discussed.

  20. The impact of bone microstructure on the field distribution of electrostimulative implants.

    PubMed

    Zimmermann, Ulf; van Rienen, Ursula

    2015-08-01

    Since the 1980s several methods of electrostimulative techniques have been developed to accelerate bone regeneration during orthopedic treatment. These techniques have proven to provide increased bone formation while curing fractures and bone diseases. The electric parameters, however, are mostly results of empiric research regarding the bone tissue as homogeneous material. Especially cancellous bone, which is the objective of a new electrostimulative total hip revision system, has a porous, inhomogeneous microstructure. The present work investigates numerically the electric field distribution within this tissue using microscopic computer tomography scans of small bone samples. The 3-dimensional X-ray absorption values of these scans are correlated with conductivity values from literature applying different correlation approaches. Compared to electric fields within a homogeneous material strong elevations can be observed within the structures which include most of the bone forming cells.

  1. Pulmonary ventilation/perfusion scan

    MedlinePlus

    ... JavaScript. A pulmonary ventilation/perfusion scan involves two nuclear scan tests to measure breathing (ventilation) and circulation ( ... In: Mettler FA, Guiberteau MJ, eds. Essentials of Nuclear Medicine Imaging . 6th ed. Philadelphia, PA: Elsevier Saunders; ...

  2. Traumatic retroperitoneal hematoma illustrated on Tc-99m methylene diphosphonate bone scintigraphy in a patient presenting with a fall.

    PubMed

    Nguyen, Huong Van; Chiam, Quee Li; Dixson, Hugh; Goddard, Kim A

    2007-08-01

    Retroperitoneal haematoma is rarely described in the context of bone scintigraphy, as it is usually an incidental discovery on bone scan carried out for another purpose. We report a case of a right retroperitoneal haematoma detected on Tc-99m-methylene diphosphonate bone scintigraphy taken in an elderly patient presenting with a mechanical fall and a right acetabular fracture.

  3. Rotational scanning atomic force microscopy.

    PubMed

    Ulčinas, A; Vaitekonis, Š

    2017-03-10

    A non-raster scanning technique for atomic force microscopy (AFM) imaging which combines rotational and translational motion is presented. The use of rotational motion for the fast scan axis allows us to significantly increase the scanning speed while imaging a large area (diameter > 30 μm). An image reconstruction algorithm and the factors influencing the resolution of the technique are discussed. The experimental results show the potential of the rotational scanning technique for high-throughput large area AFM investigation.

  4. Rotational scanning atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Ulčinas, A.; Vaitekonis, Š.

    2017-03-01

    A non-raster scanning technique for atomic force microscopy (AFM) imaging which combines rotational and translational motion is presented. The use of rotational motion for the fast scan axis allows us to significantly increase the scanning speed while imaging a large area (diameter > 30 μm). An image reconstruction algorithm and the factors influencing the resolution of the technique are discussed. The experimental results show the potential of the rotational scanning technique for high-throughput large area AFM investigation.

  5. Bone Composition Diagnostics: Photoacoustics Versus Ultrasound

    NASA Astrophysics Data System (ADS)

    Yang, Lifeng; Lashkari, Bahman; Mandelis, Andreas; Tan, Joel W. Y.

    2015-06-01

    Ultrasound (US) backscatter from bones depends on the mechanical properties and the microstructure of the interrogated bone. On the other hand, photoacoustics (PA) is sensitive to optical properties of tissue and can detect composition variation. Therefore, PA can provide complementary information about bone health and integrity. In this work, a comparative study of US backscattering and PA back-propagating signals from animal trabecular bones was performed. Both methods were applied using a linear frequency modulation chirp and matched filtering. A 2.2 MHz ultrasonic transducer was employed to detect both signals. The use of the frequency domain facilitates spectral analysis. The variation of signals shows that in addition to sensitivity to mineral changes, PA exhibits sensitivity to changes in the organic part of the bone. It is, therefore, concluded that the combination of both modalities can provide complementary detailed information on bone health than either method separately. In addition, comparison of PA and US depthwise images shows the higher penetration of US. Surface scan images exhibit very weak correlation between US and PA which could be caused by the different signal generation origins in mechanical versus optical properties, respectively.

  6. Image-Based Modeling of Trabecular Bones

    NASA Astrophysics Data System (ADS)

    Rajapakse, Chamith; Gunaratne, Gemunu

    2004-10-01

    Osteoporosis is a major health problem in the U.S. today. The detection and treatment of osteoporosis is currently based on Bone Mineral Density (BMD) measurements. Recent evidence suggests that the low bone mass alone does not account for the entire risk of osteoporotic fractures. It is also been known that the trabecular regions of bones play a major role in the bone strength . Trabecular bone has a complex structure with substantial heterogeneity, anisotropy and asymmetry. Although these properties effect BMD, the role of architecture and tissue material remain uncertain. Computer modeling of trabecular bone can be used predict responses that cannot be obtained experimentally, and they can compute responses that cannot be measured in-vivo. Due to the complexity of the Trabecular Architecture (TA) a model system based on scanned digital images is introduced to get substantial insight of TA and to predict the failure behavior. It is assumed that the added insight provided by these studies will lead to improved diagnostics and treatments of patient-specific osteoporotic fractures.

  7. Enhancing Quality of Life for Breast Cancer Patients with Bone Metastases

    DTIC Science & Technology

    2007-03-01

    Effects of human breast cancer cell on bone mineral density. Terminal DEXA scans demonstrated a significant increase in BMD in mice treated with PTH...radiographs, DEXA scans , and µCT; mice will receive two series of bone labels which will be used to examine bone formation. As in study two, this will be a...nude mice were injected with breast cancer cells; the left limb served as a sham-operated control. Radiographs and DEXA scans were obtained at the time

  8. The Scanning Process: Getting Started.

    ERIC Educational Resources Information Center

    Renfro, William L.; Morrison, James L.

    1983-01-01

    Scanning the external environment will become more essential to colleges in the coming decade. Developing an environmental scanning system can identify important emerging issues that may constitute either threats or opportunities. The organizational features of a mature scanning process are described. (MLW)

  9. Characterization of bone microstructure using photoacoustic spectrum analysis.

    PubMed

    Feng, Ting; Perosky, Joseph E; Kozloff, Kenneth M; Xu, Guan; Cheng, Qian; Du, Sidan; Yuan, Jie; Deng, Cheri X; Wang, Xueding

    2015-09-21

    Osteoporosis is a progressive bone disease that is characterized by a decrease in bone mass and the deterioration in bone microarchitecture. This study investigates the feasibility of characterizing bone microstructure by analyzing the frequency spectrum of the photoacoustic (PA) signal from the bone. Modeling and numerical simulation of PA signal were performed on trabecular bone simulations and CT scans with different trabecular thicknesses. The resulting quasi-linear photoacoustic spectra were fittted by linear regression, from which the spectral parameter slope was quantified. The simulation based on two different models both demonstrate that bone specimens with thinner trabecular thicknesses have higher slope. Experiment on osteoporotic rat femoral heads with different mineral content was conducted. The finding from the experiment was in good agreement with the simulation, demonstrating that the frequency-domain analysis of PA signals can provide an objective assessment of bone microstructure and deterioration. Considering that PA measurement is non-ionizing, non-invasive, and has sufficient penetration in both calcified and non-calcified tissues, this new bone evaluation method based on photoacoustic spectral analysis holds potential for clinical management of osteoporosis and other bone diseases.

  10. Permeability study of cancellous bone and its idealised structures.

    PubMed

    Syahrom, Ardiyansyah; Abdul Kadir, Mohammed Rafiq; Harun, Muhamad Nor; Öchsner, Andreas

    2015-01-01

    Artificial bone is a suitable alternative to autografts and allografts, however their use is still limited. Though there were numerous reports on their structural properties, permeability studies of artificial bones were comparably scarce. This study focused on the development of idealised, structured models of artificial cancellous bone and compared their permeability values with bone surface area and porosity. Cancellous bones from fresh bovine femur were extracted and cleaned following an established protocol. The samples were scanned using micro-computed tomography (μCT) and three-dimensional models of the cancellous bones were reconstructed for morphology study. Seven idealised and structured cancellous bone models were then developed and fabricated via rapid prototyping technique. A test-rig was developed and permeability tests were performed on the artificial and real cancellous bones. The results showed a linear correlation between the permeability and the porosity as well as the bone surface area. The plate-like idealised structure showed a similar value of permeability to the real cancellous bones.

  11. A scanning cavity microscope

    PubMed Central

    Mader, Matthias; Reichel, Jakob; Hänsch, Theodor W.; Hunger, David

    2015-01-01

    Imaging the optical properties of individual nanosystems beyond fluorescence can provide a wealth of information. However, the minute signals for absorption and dispersion are challenging to observe, and only specialized techniques requiring sophisticated noise rejection are available. Here we use signal enhancement in a high-finesse scanning optical microcavity to demonstrate ultra-sensitive imaging. Harnessing multiple interactions of probe light with a sample within an optical resonator, we achieve a 1,700-fold signal enhancement compared with diffraction-limited microscopy. We demonstrate quantitative imaging of the extinction cross-section of gold nanoparticles with a sensitivity less than 1 nm2; we show a method to improve the spatial resolution potentially below the diffraction limit by using higher order cavity modes, and we present measurements of the birefringence and extinction contrast of gold nanorods. The demonstrated simultaneous enhancement of absorptive and dispersive signals promises intriguing potential for optical studies of nanomaterials, molecules and biological nanosystems. PMID:26105690

  12. Fetal cardiac scanning today.

    PubMed

    Allan, Lindsey

    2010-07-01

    The ability to examine the structure of the fetal heart in real-time started over 30 years ago now. The field has seen very great advances since then, both in terms of technical improvements in ultrasound equipment and in dissemination of operator skills. A great deal has been learnt about normal cardiac function in the human fetus throughout gestation and how it is affected by pathologies of pregnancy. There is increasing recognition of abnormal heart structure during routine obstetric scanning, allowing referral for specialist diagnosis and counselling. It is now possible to make accurate diagnosis of cardiac malformations as early as 12 weeks of gestation. Early diagnosis of a major cardiac malformation in the fetus can provide the parents with a comprehensive prognosis, enabling them to make the most informed choice about the management of the pregnancy.

  13. Telescopic horizon scanning.

    PubMed

    Koenderink, Jan

    2014-12-20

    The problem of "distortionless" viewing with terrestrial telescopic systems (mainly "binoculars") remains problematic. The so called "globe effect" is only partially counteracted in modern designs. Theories addressing the phenomenon have never reached definitive closure. In this paper, we show that exact distortionless viewing with terrestrial telescopic systems is not possible in general, but that it is in principle possible in-very frequent in battle field and marine applications-the case of horizon scanning. However, this involves cylindrical optical elements. For opto-electronic systems, a full solution is more readily feasible. The solution involves a novel interpretation of the relevant constraints and objectives. For final design decisions, it is not necessary to rely on a corpus of psychophysical (or ergonomic) data, although one has to decide whether the instrument is intended as an extension of the eye or as a "pictorial" device.

  14. Muscle force regulates bone shaping for optimal load-bearing capacity during embryogenesis.

    PubMed

    Sharir, Amnon; Stern, Tomer; Rot, Chagai; Shahar, Ron; Zelzer, Elazar

    2011-08-01

    The vertebrate skeleton consists of over 200 individual bones, each with its own unique shape, size and function. We study the role of intrauterine muscle-induced mechanical loads in determining the three-dimensional morphology of developing bones. Analysis of the force-generating capacity of intrauterine muscles in mice revealed that developing bones are subjected to significant and progressively increasing mechanical challenges. To evaluate the effect of intrauterine loads on bone morphogenesis and the contribution of the emerging shape to the ability of bones to withstand these loads, we monitored structural and mineral changes during development. Using daily micro-CT scans of appendicular long bones we identify a developmental program, which we term preferential bone growth, that determines the specific circumferential shape of each bone by employing asymmetric mineral deposition and transient cortical thickening. Finite element analysis demonstrates that the resulting bone structure has optimal load-bearing capacity. To test the hypothesis that muscle forces regulate preferential bone growth in utero, we examine this process in a mouse strain (mdg) that lacks muscle contractions. In the absence of mechanical loads, the stereotypical circumferential outline of each bone is lost, leading to the development of mechanically inferior bones. This study identifies muscle force regulation of preferential bone growth as the module that shapes the circumferential outline of bones and, consequently, optimizes their load-bearing capacity during development. Our findings invoke a common mechanism that permits the formation of different circumferential outlines in different bones.

  15. Scanning the periphery.

    PubMed

    Day, George S; Schoemaker, Paul J H

    2005-11-01

    Companies often face new rivals, technologies, regulations, and other environmental changes that seem to come out of left field. How can they see these changes sooner and capitalize on them? Such changes often begin as weak signals on what the authors call the periphery, or the blurry zone at the edge of an organization's vision. As with human peripheral vision, these signals are difficult to see and interpret but can be vital to success or survival. Unfortunately, most companies lack a systematic method for determining where on the periphery they should be looking, how to interpret the weak signals they see, and how to allocate limited scanning resources. This article provides such a method-a question-based framework for helping companies scan the periphery more efficiently and effectively. The framework divides questions into three categories: learning from the past (What have been our past blind spots? What instructive analogies do other industries offer? Who in the industry is skilled at picking up weak signals and acting on them?); evaluating the present (What important signals are we rationalizing away? What are our mavericks, outliers, complainers, and defectors telling us? What are our peripheral customers and competitors really thinking?); and envisioning the future (What future surprises could really hurt or help us? What emerging technologies could change the game? Is there an unthinkable scenario that might disrupt our business?). Answering these questions is a good first step toward anticipating problems or opportunities that may appear on the business horizon. The article concludes with a self-test that companies can use to assess their need and capability for peripheral vision.

  16. Effect of intravenous pamidronate on bone markers and local bone mineral density in fibrous dysplasia.

    PubMed

    Parisi, Muriel S; Oliveri, Beatriz; Mautalen, Carlos A

    2003-10-01

    Bisphosphonates have proven to be effective in patients with fibrous dysplasia of the bone (FD) as shown by their effect on bone pain, markers of bone turnover, or radiological changes. The aim of this study was to evaluate the usefulness of measuring bone mineral density (BMD) of affected bones to assess the efficacy of bisphosphonate treatment. Seven patients (mean age 26 years) received courses of 180 mg intravenous infusion of pamidronate every 6 months (60 mg/day during 3 days). Clinical symptoms, serum alkaline phosphatase, and urinary C-terminal cross-linking telopeptide of type I collagen were assessed every 3 months. BMD of total skeleton and X-rays of FD areas (FDa) were performed at baseline and at 12 months. BMD of FDa was compared with the contralateral side (CL) using the region of interest program on the total skeleton scan. BMD of total skeleton was normal at baseline. Average BMD of FDa was -11.4% compared with CL, a significantly greater difference than that observed between the left and right sides in healthy controls, -0.7% (P < 0.02). At 12 months bone pain diminished in all patients. Bone turnover markers decreased. Mean total skeleton BMD increased 3.3% (P < 0.02). Subregions of the total skeleton scan presenting FD lesions augmented: arms +9.6% (P < 0.02), legs +4.2%, and pelvis +3.5% (P < 0.05). The increase in mean BMD of FDa was +6.8% compared with +2.6% in CL. No changes were observed on the X-ray. These results indicate that simultaneous determination of markers of bone turnover and BMD of FDa is useful in short-term follow-up to determine the efficacy of intravenous pamidronate.

  17. Vaccination with DKK1-derived peptides promotes bone formation and bone mass in an aged mouse osteoporosis model.

    PubMed

    Wu, Qiong; Li, Rui-Shu; Zhao, Yue; Wang, Zhi-Xia; Tang, Yan-Chun; Zhang, Jing; Liu, Jian-Ning; Tan, Xiang-Yang

    2014-08-01

    The investigation of agents for the treatment of osteoporosis has been a long-standing effort. The Wnt pathway plays an important role in bone formation and regeneration, and expression of Wnt pathway inhibitors, Dickkopf-1 (DKK1), appears to be associated with changes in bone mass. Inactivation of DKK1 leads to substantially increased bone mass in genetically manipulated animals. DKK1-derived peptides (DDPs) were added to BMP2-stimulated MC3T3-E1 preosteoblastic cells in vitro to evaluate inhibitory activity of DDPs in MC3T3-E1 cell differentiation. Study was extended in vivo on old female mice to show whether or not inhibition of endogenous DKK1 biological activity using DDPs vaccination approach leads to increase of bone formation, bone density, and improvement of bone microstructure. We reported that synthetic DDPs were able to reduce alkaline phosphatase activity, prevent mineralization and inhibit the differentiation of MC3T3-E1 cells in vitro. Furthermore, vaccination with these DDPs in aged female mice 4 times for a total period of 22 weeks promoted bone mass and bone microstructure. 3D microCT and histomorphometric analysis showed that there were significant increase in bone mineral densities, improvement of bone microstructure and promotion of bone formation in the vaccinated mice, especially in the mice vaccinated with DDP-A and DDP-C. Histological and scanning electron microscopy image analysis also indicated that vaccination increased trabecular bone mass and significantly decreased fragmentation of bone fibers. Taken together, these preclinical results suggest that vaccination with DDPs represents a promising new therapeutic approach for the treatment of bone-related disorders, such as osteoporosis.

  18. Bone marrow culture

    MedlinePlus

    ... There may be some bleeding at the puncture site. More serious risks, such as serious bleeding or infection, are very rare. Alternative Names Culture - bone marrow Images Bone marrow aspiration References ...

  19. Bone fracture repair - slideshow

    MedlinePlus

    ... page: //medlineplus.gov/ency/presentations/100077.htm Bone fracture repair - series—Indications To use the sharing features ... Go to slide 4 out of 4 Overview Fractures of the bones are classified in a number ...

  20. Smoking and Bone Health

    MedlinePlus

    ... Management Strategies Resources For Your Information Facts About Osteoporosis Osteoporosis is a condition in which bones weaken ... adopt new habits for healthy bones. Smoking and Osteoporosis Cigarette smoking was first identified as a risk ...

  1. Phase Equilibria of the Cu-Ti-Er System at 773 K (500 °C) and Stability of the CuTi3 Phase

    NASA Astrophysics Data System (ADS)

    Zhan, Yongzhong; Peng, Dan; She, Jia

    2012-11-01

    The phase relationships of the Cu-Ti-Er ternary phase diagram at 773 K (500 °C) were investigated mainly by means of X-ray powder diffraction (XRD), scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS), and differential thermal analysis (DTA). It is confirmed in this work that the binary compounds Cu9Er2 and Cu7Er2 exist in the Cu-Er binary system at 773 K (500 °C). The stability of the CuTi3 phase is confirmed in the Cu-Ti system. After heat treatment at 1023 K (750 °C) for 90 hours, the phase CuTi3 is observed in the microstructure of the alloy 25Cu75Ti. The temperature of the eutectoid transformation, namely, β-Ti ↔ α-Ti + CuTi3, is determined to be 1078 K (805 °C) in this work. The 773 K (500 °C) isothermal section consists of 14 single-phase regions, 25 two-phase regions, and 12 three-phase regions. None of the phases in this system reveals a remarkable homogeneity range at 773 K (500 °C).

  2. Skeletal assessment in neuroblastoma--the pitfalls of iodine-123-MIBG scans

    SciTech Connect

    Gordon, I.; Peters, A.M.; Gutman, A.; Morony, S.; Dicks-Mireaux, C.; Pritchard, J. )

    1990-02-01

    This study was carried out to compare iodine-123 metaiodobenzylguanidine ((I123I)MIBG) and technetium-99m-methylene diphosphonate bone scans ({sup 99m}Tc-MDP) in the detection of skeletal involvement by neuroblastoma. Forty-four children with neuroblastoma underwent both ({sup 123}I) MIBG and {sup 99m}Tc-MDP scans within a 4-wk period; bone marrow examination also was performed; all these investigations were done both at diagnosis and at follow-up. At diagnosis, four children with Stage 4 disease had normal ({sup 123}I)MIBG scans but abnormal {sup 99m}Tc-MDP scans, while at follow-up there were four children with negative ({sup 123}I)MIBG studies who later died from disseminated neuroblastoma. All eight scans are considered false-negative. In 24 children, the ({sup 123}I)MIBG revealed more extensive disease with 161 positive sites while the {sup 99m}Tc-MDP scan showed only 100 positive sites; 34 of these sites were common to both studies. This study shows that underassessment of skeletal involvement by neuroblastoma occurred using ({sup 123}I)MIBG scans and that one cannot therefore substitute ({sup 123}I)MIBG for {sup 99m}Tc-MDP bone scans in the staging of neuroblastoma.

  3. A Biphasic Calcium Sulphate/Hydroxyapatite Carrier Containing Bone Morphogenic Protein-2 and Zoledronic Acid Generates Bone.

    PubMed

    Raina, Deepak Bushan; Isaksson, Hanna; Hettwer, Werner; Kumar, Ashok; Lidgren, Lars; Tägil, Magnus

    2016-05-18

    In orthopedic surgery, large amount of diseased or injured bone routinely needs to be replaced. Autografts are mainly used but their availability is limited. Commercially available bone substitutes allow bone ingrowth but lack the capacity to induce bone formation. Thus, off-the-shelf osteoinductive bone substitutes that can replace bone grafts are required. We tested the carrier properties of a biphasic, calcium sulphate and hydroxyapatite ceramic material, containing a combination of recombinant human bone morphogenic protein-2 (rhBMP-2) to induce bone, and zoledronic acid (ZA) to delay early resorption. In-vitro, the biphasic material released 90% of rhBMP-2 and 10% of ZA in the first week. No major changes were found in the surface structure using scanning electron microscopy (SEM) or in the mechanical properties after adding rhBMP-2 or ZA. In-vivo bone formation was studied in an abdominal muscle pouch model in rats (n = 6/group). The mineralized volume was significantly higher when the biphasic material was combined with both rhBMP-2 and ZA (21.4 ± 5.5 mm(3)) as compared to rhBMP-2 alone (10.9 ± 2.1 mm(3)) when analyzed using micro computed tomography (μ-CT) (p < 0.01). In the clinical setting, the biphasic material combined with both rhBMP-2 and ZA can potentially regenerate large volumes of bone.

  4. Isolation, cultivation and characterisation of pigeon osteoblasts seeded on xenogeneic demineralised cancellous bone scaffold for bone grafting.

    PubMed

    Harvanová, Denisa; Hornák, Slavomír; Amrichová, Judita; Spaková, Tímea; Mikes, Jaromír; Plsíková, Jana; Ledecký, Valent; Rosocha, Ján

    2014-09-01

    Avian osteoblasts have been isolated particularly from chicken embryo, but data about other functional tissue sources of adult avian osteoblast precursors are missing. The method of preparation of pigeon osteoblasts is described in this study. We demonstrate that pigeon cancellous bone derived osteoblasts have particular proliferative capacity in vitro in comparison to mammalian species and developed endogenous ALP. Calcium deposits formation in vitro was confirmed by alizarin red staining. Only a few studies have attempted to investigate bone grafting and treatment of bone loss in birds. Lack of autologous bone grafts in birds has prompted investigation into the use of avian xenografts for bone augmentation. Here we present a method of xenografting of ostrich demineralised cancellous bone scaffold seeded with allogeneic adult pigeon osteoblasts. Ostrich demineralised cancellous bone scaffold supported proliferation of pigeon osteoblasts during two weeks of co - cultivation in vitro. Scanning electron microscopy demonstrated homogeneous adult pigeon osteoblasts attachment and distribution on the surface of xenogeneic ostrich demineralised cancellous bone. Our preliminary in vitro results indicate that demineralised cancellous bone from ostrich tibia could provide an effective biological support for growth and proliferation of allogeneic osteoblasts derived from cancellous bone of pigeons.

  5. Nurse exposure doses resulted from bone scintigraphy patient

    NASA Astrophysics Data System (ADS)

    Tunçman, Duygu; Kovan, Bilal; Poyraz, Leyla; ćapali, Veli; Demir, Bayram; Türkmen, Cüneyt

    2016-03-01

    Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It's general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget's disease, investigation of loosening and infection in orthopedic implants. It is applied with using 99mTc labeled radiopharmaceuticals (e.g 99m Tc MDP,99mTc HEDP and 99mTc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. When some patient's situation is not good, patients are hospitalized until the scanning because of patients' close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse's exposure radiations from patient's routine treatment, examination and emergency station.

  6. Onlay bone graft maintenance using guided bone regeneration, platelet rich plasma, and their combination.

    PubMed

    Younis, Mohammed; Elshahat, Ahmed; Elhabbaa, Gamal; Fareed, Ahmed; Safe, Ikram

    2014-11-01

    Onlay bone grafts have a bad reputation of resorption with loss of contour and volume. Rigid fixation reduces the incidence of resorption but does not prevent it. Literature shows reduction of resorption by applying guided bone regeneration (GBR) barriers and platelet-rich plasma (PRP). Investigating the effect of combining them together to reduce resorption was the aim of this study. This study included 4 groups: control group, GBR group, PRP group, and GBR + PRP group. Twenty rabbits were used (40 mandibular halves). Onlay bone grafts were fixed by titanium miniscrews in all groups. Computed tomography scans of harvested mandibles after euthanasia allowed calculations of bone graft volume and density. Onlay bone graft volumes in all experimental groups were significantly higher than in the control group. Volume maintenance in the GBR group was significantly higher than in the PRP group. There was no significant difference in the volume of onlay bone grafts between the group of combined GBR + PRP and GBR alone. It was concluded that, to maintain the volume of onlay bone grafts, either GBR or PRP can be added. Combining them did not add any advantage over the GBR alone.

  7. Indications for and limitations of bone scintigraphy in osteogenic sarcoma: a review of 55 patients

    SciTech Connect

    McKillop, J.H.; Etcubanas, E.; Goris, M.L.

    1981-09-01

    The value of radioisotope bone scanning at the time of presentation and serially during follow-up has been evaluated in 55 patients with biopsy-proven osteogenic sarcoma. Many of the patients studied were treated with adjuvant chemotherapy. Bone metastases were detected at presentation in only one patient and in a second patient, proximal extension of the primary tumor not evident on radiographs was demonstrated by the radioisotope technique. During fellow-up, 20 patients experienced bone metastases and each had an abnormal bone scan. Eleven of these patients were asymptomatic for bone metastases at the time the scan became abnormal. Seven patients experienced bone metastases as their first site of tumor recurrence. The detection rate for soft tissue metastases was low, but the scan indicated stump recurrence in three patients. Although the yield is small, bone scanning is justified at presentation be cause the results may profoundly after the management. During follow-up, routine bone cans are indicated in all patients, whether they have symptoms or not.

  8. Medicines and Bone Loss

    MedlinePlus

    ... studies also show that drinking a lot of alcohol might weaken bones. Questions to ask your doctor • Do any of my medicines cause bone loss? • Are there different medicines I can take? • Do I need a bone density test? • What should I do to protect my ...

  9. Temporal bone meningiomas.

    PubMed

    Hooper, R; Siu, K; Cousins, V

    1990-10-01

    Meningiomas should be considered in the differential diagnosis of space-occupying lesions of the temporal bone. Five cases of meningiomas of the temporal bone are described and the literature reviewed. These tumours may stimulate Schwannomas and glomus tumours in their presentation and radiological findings. The tumours were managed by combining standard neurosurgical approaches with temporal bone and skull base techniques.

  10. Derivation of Instantaneous Wye and Zero-Phase Sequence Voltages from Line-Line Voltages in Unbalanced 3-Phase 3-Wire Systems and Application of This Method to 3-Phase PWM Converter Control

    NASA Astrophysics Data System (ADS)

    Yuzurihara, Itsuo; Kawamura, Atsuo

    In general, voltage imbalances in 3-phase AC power systems are inevitable. 3-Phase PWM (Pulse Width Modulation) converter used in 3-wire systems are generally designed for use under limited imbalances of input voltages, and problems such as input current distortion, deterioration of output properties, degradation of efficiency and failure may occur in some cases. These problems cause severe damages to industries in some cases, for example, semiconductor production machines: SEMI defined “SEMI F47-0200” and “SEMI F47-0706” standards that have to be satisfied to realize voltage sag immunity. In order to compensate the remained problems due to the unbalanced input voltages, particular storage devices are designed additionally for conventional converters. This paper proposes that the determination of both the instantaneous zero-phase sequence voltage and wye voltages is essential for 3-phase PWM converter control used for a 3-wire system to keep its output rated under occasional or long-term voltage imbalances in an AC system. This paper also describes a general new method to derive the components of the voltages of instantaneous wye and zero-phase sequence voltage from line-line voltages of a 3-wire system. This paper also describes a method to apply the voltages to control the converter. The results obtained on implementation verify that this new converter keeps its output rated under unbalanced conditions wider than those defined by SEMIs without particular storage devices as far as the AC voltages are remained live.

  11. Earth observing scanning polarimeter

    NASA Technical Reports Server (NTRS)

    Travis, Larry

    1993-01-01

    Climate forcing by tropospheric aerosols is receiving increased attention because of the realization that the climate effects may be large, while our knowledge of global aerosol characteristics and temporal changes is very poor. Tropospheric aerosols cause a direct radiative forcing due simply to their scattering and absorption of solar radiation, as well as an indirect effect as cloud condensation nuclei which can modify the shortwave reflectivity of clouds. Sulfate aerosols tend to increase planetary albedo through both the direct and indirect effects; a cooling due to anthropogenic sulfate aerosols has been estimated of order 1 W/sq m, noting that this is similar in magnitude to the present anthropogenic greenhouse gas warming. Other aerosols, including those from biomass burning and wind-blown desert dust are also of potential climatic importance. At present, the only global monitoring of tropospheric aerosols is a NOAA operational product, aerosol optical thickness, obtained using channel-1 (0.58-0.68 mu m) radiances from the AVHRR. With this single channel radiance data, one must use an approach which is based on the inferred excess of reflected radiance owing to scattering by the aerosols over that expected from theoretical calculations. This approach is suited only for situations where the surface has a low albedo that is well known a priori. Thus, the NOAA operational product is restricted to coverage over the ocean at AVHRR scan angles well away from sun glint, and aerosol changes are subject to confusion with changes caused by either optically thin or subpixel clouds. Because optically thin aerosols have only a small effect on the radiance, accurate measurements for optical thickness less than 0.1 (which is a typical background level) are precluded. Moreover, some of the largest and most important aerosol changes are expected over land. The Earth Observing Scanning Polarimeter (EOSP) instrument, based upon design heritage and analysis techniques

  12. LANL Robotic Vessel Scanning

    SciTech Connect

    Webber, Nels W.

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  13. Differential scanning calorimetry.

    PubMed

    Spink, Charles H

    2008-01-01

    Differential scanning calorimetry (DSC) has emerged as a powerful experimental technique for determining thermodynamic properties of biomacromolecules. The ability to monitor unfolding or phase transitions in proteins, polynucleotides, and lipid assemblies has not only provided data on thermodynamic stability for these important molecules, but also made it possible to examine the details of unfolding processes and to analyze the characteristics of intermediate states involved in the melting of biopolymers. The recent improvements in DSC instrumentation and software have generated new opportunities for the study of the effects of structure and changes in environment on the behavior of proteins, nucleic acids, and lipids. This review presents some of the details of application of DSC to the examination of the unfolding of biomolecules. After a brief introduction to DSC instrumentation used for the study of thermal transitions, the methods for obtaining basic thermodynamic information from the DSC curve are presented. Then, using DNA unfolding as an example, methods for the analysis of the melting transition are presented that allow deconvolution of the DSC curves to determine more subtle characteristics of the intermediate states involved in unfolding. Two types of transitions are presented for analysis, the first example being the unfolding of two large synthetic polynucleotides, which display high cooperativity in the melting process. The second example shows the application of DSC for the study of the unfolding of a simple hairpin oligonucleotide. Details of the data analysis are presented in a simple spreadsheet format.

  14. GPR scan assessment

    NASA Astrophysics Data System (ADS)

    Abbas, Abbas M.; Salah, Hany; Massoud, Usama; Fouad, Mona; Abdel-Hafez, Mahmoud

    2015-06-01

    Mekaad Radwan monument is situated in the neighborhood of Bab Zuweila in the historical Cairo, Egypt. It was constructed at the middle XVII century (1635 AD). The building has a rectangle shape plan (13 × 6 m) with the longitudinal sides approximately WNW-ESE. It comprises three storages namely; the ground floor; the opened floor (RADWAN Bench) and the living floor with a total elevation of 15 m above the street level. The building suffers from severe deterioration phenomena with patterns of damage which have occurred over time. These deterioration and damages could be attributed to foundation problems, subsoil water and also to the earthquake that affected the entire Greater Cairo area in October 1992. Ground Penetrating Radar (GPR) scan was accomplished against the walls of the opened floor (RADWAN Bench) to evaluate the hazard impact on the walls textures and integrity. The results showed an anomalous feature through the southern wall of RADWAN Bench. A mathematical model has been simulated to confirm the obtained anomaly and the model response exhibited a good matching with the outlined anomaly.

  15. Method for fusing bone

    DOEpatents

    Mourant, Judith R.; Anderson, Gerhard D.; Bigio, Irving J.; Johnson, Tamara M.

    1996-01-01

    Method for fusing bone. The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  16. The mechanical behavior of PMMA/bone specimens extracted from augmented vertebrae: a numerical study of interface properties, PMMA shrinkage and trabecular bone damage.

    PubMed

    Kinzl, M; Boger, A; Zysset, P K; Pahr, D H

    2012-05-11

    Recently published compression tests on PMMA/bone specimens extracted after vertebral bone augmentation indicated that PMMA/bone composites were not reinforced by the trabecular bone at all. In this study, the reasons for this unexpected behavior should be investigated by using non-linear micro-FE models. Six human vertebral bodies were augmented with either standard or low-modulus PMMA cement and scanned with a HR-pQCT system before and after augmentation. Six cylindrical PMMA/bone specimens were extracted from the augmented region, scanned with a micro-CT system and tested in compression. Four different micro-FE models were generated from these images which showed different bone tissue material behavior (with/without damage), interface behavior (perfect bonding, frictionless contact) and PMMA shrinkage due to polymerization. The non-linear stress-strain curves were compared between the different micro-FE models as well as to the compression tests of the PMMA/bone specimens. Micro-FE models with contact between bone and cement were 20% more compliant compared to those with perfect bonding. PMMA shrinkage damaged the trabecular bone already before mechanical loading, which further reduced the initial stiffness by 24%. Progressing bone damage during compression dominated the non-linear part of the stress-strain curves. The micro-FE models including bone damage and PMMA shrinkage were in good agreement with the compression tests. The results were similar with both cements. In conclusion, the PMMA/bone interface properties as well as the initial bone damage due to PMMA polymerization shrinkage clearly affected the stress-strain behavior of the composite and explained why trabecular bone did not contribute to the stiffness and strength of augmented bone.

  17. Bone regeneration in dentistry

    PubMed Central

    Tonelli, Paolo; Duvina, Marco; Barbato, Luigi; Biondi, Eleonora; Nuti, Niccolò; Brancato, Leila; Rose, Giovanna Delle

    2011-01-01

    Summary The edentulism of the jaws and the periodontal disease represent conditions that frequently leads to disruption of the alveolar bone. The loss of the tooth and of its bone of support lead to the creation of crestal defects or situation of maxillary atrophy. The restoration of a functional condition involves the use of endosseous implants who require adequate bone volume, to deal with the masticatory load. In such situations the bone need to be regenerated, taking advantage of the biological principles of osteogenesis, osteoinduction and osteoconduction. Several techniques combine these principles with different results, due to the condition of the bone base on which we operate changes, the surgical technique that we use, and finally for the bone metabolic conditions of the patient who can be in a state of systemic osteopenia or osteoporosis; these can also affect the result of jaw bone reconstruction. PMID:22461825

  18. Nanomaterials and bone regeneration

    PubMed Central

    Gong, Tao; Xie, Jing; Liao, Jinfeng; Zhang, Tao; Lin, Shiyu; Lin, Yunfeng

    2015-01-01

    The worldwide incidence of bone disorders and conditions has been increasing. Bone is a nanomaterials composed of organic (mainly collagen) and inorganic (mainly nano-hydroxyapatite) components, with a hierarchical structure ranging from nanoscale to macroscale. In consideration of the serious limitation in traditional therapies, nanomaterials provide some new strategy in bone regeneration. Nanostructured scaffolds provide a closer structural support approximation to native bone architecture for the cells and regulate cell proliferation, differentiation, and migration, which results in the formation of functional tissues. In this article, we focused on reviewing the classification and design of nanostructured materials and nanocarrier materials for bone regeneration, their cell interaction properties, and their application in bone tissue engineering and regeneration. Furthermore, some new challenges about the future research on the application of nanomaterials for bone regeneration are described in the conclusion and perspectives part. PMID:26558141

  19. Bone scintiscanning updated.

    PubMed

    Lentle, B C; Russell, A S; Percy, J S; Scott, J R; Jackson, F I

    1976-03-01

    Use of modern materials and methods has given bone scintiscanning a larger role in clinical medicine, The safety and ready availability of newer agents have led to its greater use in investigating both benign and malignant disease of bone and joint. Present evidence suggests that abnormal accumulation of 99mTc-polyphosphate and its analogues results from ionic deposition at crystal surfaces in immature bone, this process being facilitated by an increase in bone vascularity. There is, also, a component of matrix localization. These factors are in keeping with the concept that abnormal scintiscan sites represent areas of increased osteoblastic activity, although this may be an oversimplification. Increasing evidence shows that the bone scintiscan is more sensitive than conventional radiography in detecting focal disease of bone, and its ability to reflect the immediate status of bone further complements radiographic findings. The main limitation of this method relates to nonspecificity of the results obtained.

  20. Calcium and bone disease

    PubMed Central

    Blair, Harry C.; Robinson, Lisa J.; Huang, Christopher L.-H.; Sun, Li; Friedman, Peter A.; Schlesinger, Paul H.; Zaidi, Mone

    2013-01-01

    Calcium transport and calcium signaling are of basic importance in bone cells. Bone is the major store of calcium and a key regulatory organ for calcium homeostasis. Bone, in major part, responds to calcium-dependent signals from the parathyroids and via vitamin D metabolites, although bone retains direct response to extracellular calcium if parathyroid regulation is lost. Improved understanding of calcium transporters and calcium-regulated cellular processes has resulted from analysis of genetic defects, including several defects with low or high bone mass. Osteoblasts deposit calcium by mechanisms including phosphate and calcium transport with alkalinization to absorb acid created by mineral deposition; cartilage calcium mineralization occurs by passive diffusion and phosphate production. Calcium mobilization by osteoclasts is mediated by acid secretion. Both bone forming and bone resorbing cells use calcium signals as regulators of differentiation and activity. This has been studied in more detail in osteoclasts, where both osteoclast differentiation and motility are regulated by calcium. PMID:21674636

  1. Marble Bone Disease: A Rare Bone Disorder

    PubMed Central

    Harinathbabu, Maheswari; Thillaigovindan, Ranjani; Prabhu, Geetha

    2015-01-01

    Osteopetrosis, or marble bone disease, is a rare skeletal disorder due to a defective function of the osteoclasts. This defect renders bones more susceptible to osteomyelitis due to decreased vascularity. This disorder is inherited as autosomal dominant and autosomal recessive. Healthcare professionals should urge these patients to maintain their oral health as well as general health, as this condition makes these patients more susceptible to frequent infections and fractures. This case report emphasizes the signs and symptoms of marble bone disease and presents clinical and radiographic findings.  PMID:26594603

  2. Increase of Compact Bone Thickness in Rat Tibia after Implanting MgO into the Bone Marrow Cavity

    PubMed Central

    Nygren, Håkan; Chaudhry, Mobina; Gustafsson, Stefan; Kjeller, Göran; Malmberg, Per; Johansson, Kjell-Erik

    2014-01-01

    The effect of implanting MgO paste into the bone marrow of rat tibia, was studied by light microscopy, time of flight-secondary ion mass spectrometry (ToF-SIMS), and environmental scanning electron microscopy (ESEM), and energy dispersive X-ray (EDX) analysis. After three weeks of implantation, the thickness of compact bone increased by 25% compared to sham-operated controls, while no effect was seen on the trabecular bone. In order to further elucidate the mechanism of the Mg-induced increase in bone mass, EDX and ToF-SIMS analysis of the bone samples was made at two weeks. At this time-point, no detectable difference in the thickness of the compact bone in Mg-treated and non-treated animals was observed. The Mg-content of the bone marrow and bone tissue of the Mg-exposed animals did not differ from that of sham-operated controls, implying that there are no traces of the implanted MgO when the mass of compact bone increases, between two and three weeks after surgery. The ratio of Mg/Ca content was higher in the bone of Mg-treated animals, indicating an altered structure of the bone mineral, which was confirmed by the ToF-SIMS analysis, showing increased levels of MgCO3, phosphate ions and CaF in the bone of MgO-exposed animals. Possible cellular activities behind the effect of MgO on compact bone thickness are discussed. PMID:25215425

  3. Effects of osteoporosis and nutrition supplements on structures and nanomechanical properties of bone tissue.

    PubMed

    Chang, Yuan-Ting; Chen, Chuan-Mu; Tu, Min-Yu; Chen, Hsiao-Ling; Chang, Shou-Yi; Tsai, Tung-Chou; Wang, Ying-Ting; Hsiao, Hsiang-Long

    2011-10-01

    In this study, the bone structures, nanomechanical properties and fracture behaviors in different groups of female C57BL/6 mice (control, sham operated, ovariectomized, casein supplemented, and fermented milk supplemented) were examined by micro-computed tomography, scanning and transmission electron microscopy, and nanoindentation. The control and sham operated mice showed dense bone structures with high cortical bone mineral densities of 544 mg/cm(3) (average) and high hardness of 0.9-1.1 GPa; resistance to bone fracture was conferred by microcracking, crack deflections and ligament bridging attributed to aligned collagen fibers and densely packed hydroxyapatite crystals. Bone mineral density, hardness and fracture resistance in ovariectomized mice markedly dropped due to loose bone structure with randomly distributed collagens and hydroxyapatites. The acidic casein supplemented mice with blood acidosis exhibited poor mineral absorption and loose bone structure, whereas the neutralized casein or fermented milk supplemented mice were resistant to osteoporosis and had high bone mechanical properties.

  4. Anisotropy in the compressive mechanical properties of bovine cortical bone and the mineral and protein constituents.

    PubMed

    Novitskaya, Ekaterina; Chen, Po-Yu; Lee, Steve; Castro-Ceseña, Ana; Hirata, Gustavo; Lubarda, Vlado A; McKittrick, Joanna

    2011-08-01

    The mechanical properties of fully demineralized, fully deproteinized and untreated cortical bovine femur bone were investigated by compression testing in three anatomical directions (longitudinal, radial and transverse). The weighted sum of the stress-strain curves of the treated bones was far lower than that of the untreated bone, indicating a strong molecular and/or mechanical interaction between the collagen matrix and the mineral phase. Demineralization and deproteinization of the bone demonstrated that contiguous, stand-alone structures result, showing that bone can be considered an interpenetrating composite material. Structural features of the samples from all groups were studied by optical and scanning electron microscopy. Anisotropic mechanical properties were observed: the radial direction was found to be the strongest for untreated bone, while the longitudinal one was found to be the strongest for deproteinized and demineralized bones. A possible explanation for this phenomenon is the difference in bone microstructure in the radial and longitudinal directions.

  5. [Bone fracture and the healing mechanisms. Fragility fracture and bone quality].

    PubMed

    Mawatari, Taro; Iwamoto, Yukihide

    2009-05-01

    Fracture occurs in bone having less than normal elastic resistance without any violence. Numerous terms have been used to classify various types of fractures from low trauma events; "fragility fracture", "stress fracture", "insufficiency fracture", "fatigue fracture", "pathologic fracture", etc. The definitions of these terms and clinical characteristics of these fractures are discussed. Also state-of-the-art bone quality assessments; Finite element analysis of clinical CT scans, assessments of the Microdamage, and the Cross-links of Collagen are introduced in this review.

  6. Primary Splenic Angiosarcoma Revealed by Bone Marrow Metastasis

    PubMed Central

    Anoun, Soumaya; Marouane, Sofia; Quessar, Asmae; Benchekroun, Said

    2014-01-01

    Primary splenic angiosarcomas are the most common malignant non-hematopoietic tumors of the spleen. Metastatic diseases were found in 69% of patients in a reported series but the incidence of bone marrow involvement is unclear. We report a rare case of a 25-years-old Moroccan woman with unsuspected primary splenic angiosarcoma revealed by bone marrow metastasis. She presented with serious anemia and splenomegaly. Bone marrow biopsy revealed proliferating spindle cells. Computed tomography scanning showed an enlarged spleen with heterogeneous lesions. Splenectomy was performed and retrospective histological study of the spleen confirmed the diagnosis. She died 1 year after splenectomy. PMID:25541659

  7. Primary splenic angiosarcoma revealed by bone marrow metastasis.

    PubMed

    Anoun, Soumaya; Marouane, Sofia; Quessar, Asmae; Benchekroun, Said

    2014-12-05

    Primary splenic angiosarcomas are the most common malignant non-hematopoietic tumors of the spleen. Metastatic diseases were found in 69% of patients in a reported series but the incidence of bone marrow involvement is unclear. We report a rare case of a 25-years-old Moroccan woman with unsuspected primary splenic angiosarcoma revealed by bone marrow metastasis. She presented with serious anemia and splenomegaly. Bone marrow biopsy revealed proliferating spindle cells. Computed tomography scanning showed an enlarged spleen with heterogeneous lesions. Splenectomy was performed and retrospective histological study of the spleen confirmed the diagnosis. She died 1 year after splenectomy.

  8. Effects of fibrinogen concentration on fibrin glue and bone powder scaffolds in bone regeneration.

    PubMed

    Kim, Beom-Su; Sung, Hark-Mo; You, Hyung-Keun; Lee, Jun

    2014-10-01

    Fibrin polymers are widely used in the tissue engineering field as biomaterials. Although numerous researchers have studied the fabrication of scaffolds using fibrin glue (FG) and bone powder, the effects of varied fibrinogen content during the fabrication of scaffolds on human mesenchymal stem cells (hMSCs) and bone regeneration remain poorly understood. In this study, we formulated scaffolds using demineralized bone powder and various fibrinogen concentrations and analyzed the microstructure and mechanical properties. Cell proliferation, cell viability, and osteoblast differentiation assays were performed. The ability of the scaffold to enhance bone regeneration was evaluated using a rabbit calvarial defect model. Micro-computed tomography (micro-CT) showed that bone powders were uniformly distributed on the scaffolds, and scanning electron microscopy (SEM) showed that the fibrin networks and flattened fibrin layers connected adjacent bone powder particles. When an 80 mg/mL fibrinogen solution was used to formulate scaffolds, the porosity decreased 41.6 ± 3.6%, while the compressive strength increased 1.16 ± 0.02 Mpa, when compared with the values for the 10 mg/mL fibrinogen solution. Proliferation assays and SEM showed that the scaffolds prepared using higher fibrinogen concentrations supported and enhanced cell adhesion and proliferation. In addition, mRNA expression of alkaline phosphatase and osteocalcin in cells grown on the scaffolds increased with increasing fibrinogen concentration. Micro-CT and histological analysis revealed that newly formed bone was stimulated in the scaffold implantation group. Our results demonstrate that optimization of the fibrinogen content of fibrin glue/bone powder scaffolds will be beneficial for bone tissue engineering.

  9. Removal of bone in CT angiography by multiscale matched mask bone elimination

    SciTech Connect

    Gratama van Andel, H. A. F.; Venema, H. W.; Streekstra, G. J.; Straten, M. van; Majoie, C. B. L. M.; Heeten, G. J. den; Grimbergen, C. A.

    2007-10-15

    For clear visualization of vessels in CT angiography (CTA) images of the head and neck using maximum intensity projection (MIP) or volume rendering (VR) bone has to be removed. In the past we presented a fully automatic method to mask the bone [matched mask bone elimination (MMBE)] for this purpose. A drawback is that vessels adjacent to bone may be partly masked as well. We propose a modification, multiscale MMBE, which reduces this problem by using images at two scales: a higher resolution than usual for image processing and a lower resolution to which the processed images are transformed for use in the diagnostic process. A higher in-plane resolution is obtained by the use of a sharper reconstruction kernel. The out-of-plane resolution is improved by deconvolution or by scanning with narrower collimation. The quality of the mask that is used to remove bone is improved by using images at both scales. After masking, the desired resolution for the normal clinical use of the images is obtained by blurring with Gaussian kernels of appropriate widths. Both methods (multiscale and original) were compared in a phantom study and with clinical CTA data sets. With the multiscale approach the width of the strip of soft tissue adjacent to the bone that is masked can be reduced from 1.0 to 0.2 mm without reducing the quality of the bone removal. The clinical examples show that vessels adjacent to bone are less affected and therefore better visible. Images processed with multiscale MMBE have a slightly higher noise level or slightly reduced resolution compared with images processed by the original method and the reconstruction and processing time is also somewhat increased. Nevertheless, multiscale MMBE offers a way to remove bone automatically from CT angiography images without affecting the integrity of the blood vessels. The overall image quality of MIP or VR images is substantially improved relative to images processed with the original MMBE method.

  10. A Bone Glue with Sustained Adhesion under Wet Conditions.

    PubMed

    Wistlich, Laura; Rücker, Anja; Schamel, Martha; Kübler, Alexander C; Gbureck, Uwe; Groll, Jürgen

    2017-02-01

    Bone glues often suffer from low adhesion to bone under wet conditions. This study aims to improve wet adhesiveness of a bone glue based on a photocurable poly(ethylene glycol) dimethacrylate matrix through in situ interpenetrating network formation by addition of six-armed isocyanate functional star-shaped prepolymers (NCO-sP(EO-stat-PO)). Biodegradable ceramic fillers are added to adjust the paste workability. The 3-point bending strength of the bone glues is in the range of 3.5-5.5 MPa and not significantly affected by the addition of NCO-sP(EO-stat-PO). Storage in phosphate buffered saline (PBS) decreases the bending strength of all formulations to approximately 1 MPa but the adhesion to cortical bone increases from 0.15-0.2 to 0.3-0.5 MPa after adding 20-40 wt% NCO-sP(EO-stat-PO) to the matrix. Bone glues without the NCO-sP(EO-stat-PO) additive lose their adhesiveness to bone after aging in PBS for 7 days, whereas modified glues maintain a shear strength of 0.18-0.25 MPa demonstrating the efficacy of the approach. Scanning electron microscopy and energy-dispersive X-ray spectroscopy investigations of the fracture surfaces prove a high amount of residual adhesive on the bone surface indicating that adhesion to the bone under wet conditions is stronger than cohesion.

  11. Bone mineral measurement using dual energy x ray densitometry

    NASA Technical Reports Server (NTRS)

    Smith, Steven W.

    1989-01-01

    Bone mineral measurements before and after space missions have shown that weightlessness greatly accelerates bone demineralization. Bone mineral losses as high as 1 to 3 percent per month were reported. Highly precise instrumentation is required to monitor this loss and thereby test the efficacy of treatment. During the last year, a significant improvement was made in Dual-Photon Absorptiometry by replacing the radioactive source with an x ray tube. Advantages of this system include: better precision, lower patient dose, better spacial resolution, and shorter scan times. The high precision and low radiation dose of this technique will allow detection of bone mineral changes of less than 1 percent with measurements conducted directly at the sites of interest. This will allow the required bone mineral studies to be completed in a shorter time with greater confidence.

  12. [Multifocal epithelioid angiosarcoma of bone with lung metastases].

    PubMed

    Pacheco, C; Albalá, M D; Blanco, M; Hidalgo, F J

    2014-01-01

    Angiosarcoma is a rare mesenchymal neoplasm that may arise from vascular or lymphatic tissue. Bone primary angiosarcoma is extremely rare, representing less than 1% of all angiosarcomas. It́s a very aggressive neoplasm and patients have metastatic disease at initial diagnosis in a large percentage of cases. On radiographs, these lesions are usually aggressive osteolytic lesions, commonly with soft-tissue mass extension, and tumoral enhancement on CT or MR imaging. The appearance of the bone scan is variable, describing studies with tracer uptake or low uptake. These tumours are more often found in the long bones, but spinal involvement has been reported in 10% of patients. There are a few reports in the literature of bone angiosarcoma with lung metastases. We present a patient with multifocal epithelioid angiosarcoma (spine and ribs) and multiple lung metastasis, evidenced by CT and conventional bone scintigraphy, with a fast growth.

  13. Composition analysis by scanning femtosecond laser ultraprobing (CASFLU).

    DOEpatents

    Ishikawa, Muriel Y.; Wood, Lowell L.; Campbell, E. Michael; Stuart, Brent C.; Perry, Michael D.

    2002-01-01

    The composition analysis by scanning femtosecond ultraprobing (CASFLU) technology scans a focused train of extremely short-duration, very intense laser pulses across a sample. The partially-ionized plasma ablated by each pulse is spectrometrically analyzed in real time, determining the ablated material's composition. The steering of the scanned beam thus is computer directed to either continue ablative material-removal at the same site or to successively remove nearby material for the same type of composition analysis. This invention has utility in high-speed chemical-elemental, molecular-fragment and isotopic analyses of the microstructure composition of complex objects, e.g., the oxygen isotopic compositions of large populations of single osteons in bone.

  14. Continuous scanning mode for ptychography

    SciTech Connect

    Clark, Jesse N.; Huang, Xiaojing; Harder, Ross; Robinson, Ian K.

    2014-10-15

    We outline how ptychographic imaging can be performed without the need for discrete scan positions. Through an idealized experiment, we demonstrate how a discrete-position scan regime can be replaced with a continuously scanned one with suitable modification of the reconstruction scheme based on coherent modes. The impact of this is that acquisition times can be reduced, significantly aiding ptychographic imaging with x rays, electrons, or visible light.

  15. Continuous scanning mode for ptychography

    SciTech Connect

    Clark, Jesse N.; Huang, Xiaojing; Harder, Ross J.; Robinson, Ian K.

    2014-01-01

    Here, we outline how ptychographic imaging can be performed without the need for discrete scan positions. Through an idealized experiment, we demonstrate how a discrete-position scan regime can be replaced with a continuously scanned one with suitable modification of the reconstruction scheme based on coherent modes. Furthermore, the impact of this is that acquisition times can be reduced, significantly aiding ptychographic imaging with x rays, electrons, or visible light.

  16. Biological Regulation of Bone Quality

    PubMed Central

    Alliston, Tamara

    2014-01-01

    The ability of bone to resist fracture is determined by the combination of bone mass and bone quality. Like bone mass, bone quality is carefully regulated. Of the many aspects of bone quality, this review focuses on biological mechanisms that control the material quality of the bone extracellular matrix (ECM). Bone ECM quality depends upon ECM composition and organization. Proteins and signaling pathways that affect the mineral or organic constituents of bone ECM impact bone ECM material properties, such as elastic modulus and hardness. These properties are also sensitive to pathways that regulate bone remodeling by osteoblasts, osteoclasts, and osteocytes. Several extracellular proteins, signaling pathways, intracellular effectors, and transcription regulatory networks have been implicated in the control of bone ECM quality. A molecular understanding of these mechanisms will elucidate the biological control of bone quality and suggest new targets for the development of therapies to prevent bone fragility. PMID:24894149

  17. [Animal models for bone and joint disease. Assessment of bone mass, structure and strength in rat and mouse models - focus on micro-computed tomography study -].

    PubMed

    Ito, Masako

    2011-02-01

    In the assessment of quality of bone in animal models, it is required to know the differences in bone mineral density, bone structure and strength from the human bones. "Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography" has been published (2010 JBMR). For a good use of micro-CT for animal studies, the important items are explained in this article, (1) Imaging acquisition : sample preparation and positioning, X-ray scan conditions, voxel size/image resolution, region of interest (2) Image processing : filtration, segmentation (3) Terminology and algorithm of trabecular (bone volume fraction, trabecular number/thickness/separation, structure model index, connectivity, degree of anisotropy) and cortical (cross-sectional area, cortical thickness) bone morphometry.

  18. [Bone and Nutrition. Sclerostin and bone metabolism].

    PubMed

    Tatsumi, Sawako; Nagamoto, Kenta; Ogata, Mao; Miyamoto, Ken-ichi

    2015-07-01

    Osteocytes orchestrate bone resorption and bone formation by controlling osteoclast and osteoblast activity. On the other hand, osteocytes secret FGF23 (fibroblast growth factor 23), FGF23 acts on the kidney to control phosphate homeostasis. Sclerostin is also released from osteocytes and it regulated osteoblast activity through Wnt/β-catenin pathway. Therefore, an antibody that targets sclerostin is currently in phase- III clinical trials for the treatment of osteoporosis and it is expected as new therapeutics.

  19. Daily Bone Alignment With Limited Repeat CT Correction Rivals Daily Ultrasound Alignment for Prostate Radiotherapy

    SciTech Connect

    O'Daniel, Jennifer C.; Dong Lei Zhang Lifei; Wang He; Tucker, Susan L.; Kudchadker, Rajat J.; Lee, Andrew K.; Cheung, Rex; Cox, James D.; Kuban, Deborah A.; Mohan, Radhe

    2008-05-01

    Purpose: To compare the effectiveness of daily ultrasound (US)- and computed tomography (CT)-guided alignments with an off-line correction protocol using daily bone alignment plus a correction factor for systematic internal prostate displacement (CF{sub ID}). Methods and Materials: Ten prostate cancer patients underwent CT scans three times weekly using an integrated CT-linear accelerator system, followed by alignment using US for daily radiotherapy. Intensity-modulated radiotherapy plans were designed with our current clinical margins. The treatment plan was copied onto the repeat CT images and aligned using several methods: (1) bone alignment plus CF{sub ID} after three off-line CT scans (bone+3CT), (2) bone alignment plus CF{sub ID} after six off-line CT scans (bone+6CT), (3) US alignment, and (4) CT alignment. The accuracy of the repeated US and CT measurements to determine the CF{sub ID} was compared. The target dosimetric effect was quantified. Results: The CF{sub ID} for internal systematic prostate displacements was more accurately measured with limited repeat CT scans than with US (residual error, 0.0 {+-} 0.7 mm vs. 2.0 {+-} 3.2 mm). Bone+3CT, bone+6CT, and US provided equivalent prostate and seminal vesicle dose coverage, but bone+3CT and bone+6CT produced more precise daily alignments. Daily CT alignment provided the greatest target dose coverage. Conclusion: Daily bone alignment plus CF{sub ID} for internal systematic prostate displacement provided better daily alignment precision and equivalent dose coverage compared with daily US alignment. The CF{sub ID} should be based on at least three repeat CT scans, which could be collected before the start of treatment or during the first 3 treatment days. Daily bone alignment plus CF{sub ID} provides another option for accurate prostate cancer patient positioning.

  20. Determination of Small Animal Long Bone Properties Using Densitometry

    NASA Technical Reports Server (NTRS)

    Breit, Gregory A.; Goldberg, BethAnn K.; Whalen, Robert T.; Hargens, Alan R. (Technical Monitor)

    1996-01-01

    Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased

  1. [Fibrous dysplasia of bone].

    PubMed

    Orcel, Philippe; Chapurlat, Roland

    2007-10-31

    Fibrous dysplasia of bone is a congenital non hereditary benign bone disease, where normal bone is replaced by a fibrous-like tissue with immature osteogenesis. Prevalence is difficult to estimate, due to frequent asymptomatic lesions. Bone lesions are mono- or polyostotic and may be associated with bone pain and fragility, leading to fractures. In some patients or bone sites, they are hypertrophic, responsible for neurological complications. Imaging and, when necessary, histology are the cornerstones of the diagnosis. A common molecular defect, i.e. activating mutations of the GNAS gene, encoding the a subunit of the Gs protein in target cells, is responsible for bone cell alterations as well as for the involvement of other cells/tissues bearing the same molecular defect (melanocytes, endocrine cells). These mutations affect only somatic cells and are therefore not hereditary: antenatal diagnosis is not appropriate for this disease and genetic counselling is not very useful, except for reassuring the patients. The conventional therapeutic approach is essentially symptomatic (pain killers) and orthopaedic (prevention and treatment of bone complications). Recent publications have focused attention on pamidronate, which rapidly relieves bone pain in most patients, and progressively increases bone mineralization in osteolytic areas in about half of the patients. Tubular phosphate wasting is common and should be treated with phosphate supplement and calcitriol. The prognosis should improve with therapeutic advances, but this remains to be properly evaluated.

  2. Does Orthodontic Treatment Affect the Alveolar Bone Density?

    PubMed Central

    Yu, Jian-Hong; Huang, Heng-Li; Liu, Chien-Feng; Wu, Jay; Li, Yu-Fen; Tsai, Ming-Tzu; Hsu, Jui-Ting

    2016-01-01

    Abstract Few studies involving human participants have been conducted to investigate the effect of orthodontic treatment on alveolar bone density around the teeth. Our previous study revealed that patients who received 6 months of active orthodontic treatment exhibited an ∼24% decrease in alveolar bone density around the teeth. However, after an extensive retention period following orthodontic treatment, whether the bone density around the teeth can recover to its original state from before the treatment remains unclear, thus warranting further investigation. The purpose of this study was to assess the bone density changes around the teeth before, during, and after orthodontic treatment. Dental cone-beam computed tomography (CBCT) was used to measure the changes in bone density around 6 teeth in the anterior maxilla (maxilla central incisors, lateral incisors, and canines) of 8 patients before and after orthodontic treatment. Each patient underwent 3 dental CBCT scans: before treatment (T0); at the end of 7 months of active orthodontic treatment (T1); after several months (20–22 months) of retention (T2). The Friedman test was applied to evaluate the changes in the alveolar bone density around the teeth according to the 3 dental CBCT scans. From T0 to T1, a significant reduction in bone density was observed around the teeth (23.36 ± 10.33%); by contrast, a significant increase was observed from T1 to T2 (31.81 ± 23.80%). From the perspective of the overall orthodontic treatment, comparing the T0 and T2 scans revealed that the bone density around the teeth was relatively constant (a reduction of only 0.75 ± 19.85%). The results of the statistical test also confirmed that the difference in bone density between T0 and T2 was nonsignificant. During orthodontic tooth movement, the alveolar bone density around the teeth was reduced. However, after a period of bone recovery, the reduced bone density recovered to its previous state from before the

  3. Does Orthodontic Treatment Affect the Alveolar Bone Density?

    PubMed

    Yu, Jian-Hong; Huang, Heng-Li; Liu, Chien-Feng; Wu, Jay; Li, Yu-Fen; Tsai, Ming-Tzu; Hsu, Jui-Ting

    2016-03-01

    Few studies involving human participants have been conducted to investigate the effect of orthodontic treatment on alveolar bone density around the teeth. Our previous study revealed that patients who received 6 months of active orthodontic treatment exhibited an ∼24% decrease in alveolar bone density around the teeth. However, after an extensive retention period following orthodontic treatment, whether the bone density around the teeth can recover to its original state from before the treatment remains unclear, thus warranting further investigation.The purpose of this study was to assess the bone density changes around the teeth before, during, and after orthodontic treatment.Dental cone-beam computed tomography (CBCT) was used to measure the changes in bone density around 6 teeth in the anterior maxilla (maxilla central incisors, lateral incisors, and canines) of 8 patients before and after orthodontic treatment. Each patient underwent 3 dental CBCT scans: before treatment (T0); at the end of 7 months of active orthodontic treatment (T1); after several months (20-22 months) of retention (T2). The Friedman test was applied to evaluate the changes in the alveolar bone density around the teeth according to the 3 dental CBCT scans.From T0 to T1, a significant reduction in bone density was observed around the teeth (23.36 ± 10.33%); by contrast, a significant increase was observed from T1 to T2 (31.81 ± 23.80%). From the perspective of the overall orthodontic treatment, comparing the T0 and T2 scans revealed that the bone density around the teeth was relatively constant (a reduction of only 0.75 ± 19.85%). The results of the statistical test also confirmed that the difference in bone density between T0 and T2 was nonsignificant.During orthodontic tooth movement, the alveolar bone density around the teeth was reduced. However, after a period of bone recovery, the reduced bone density recovered to its previous state from before the orthodontic treatment

  4. Assessment of Long Bone Flexural Properties from Bone Densitometry

    NASA Technical Reports Server (NTRS)

    Whalen, Robert; Cleek, Tammy; Katz, BethAnn

    1994-01-01

    While bone densitometry is the accepted non-invasive method of quantifying bone mineral content in bones, its assessment of bone structural properties is less well understood. The objective of our current work is to compare cross-section shape or areal properties of long bones computed from densitometry data with cross-section flexural properties obtained from surface strain measurements.

  5. Genetic regulation of bone mass: from bone density to bone strength.

    PubMed

    Langman, Craig B

    2005-03-01

    Osteoporosis is a common disease characterized in adults by diminished bone density. Bone is an organ that evolves and grows throughout life, and establishing optimal bone density in childhood and adolescence serves to buffer bone loss later in life. Bone density, a measurable entity, is the clinical substitute for bone strength, or the ability to defend against fracture. Chronic diseases may adversely affect optimal peak bone density. Bone density is under genetic control, as revealed by three lines of investigations. These include (1) the finding of quantitative trait loci for bone density, (2) the finding that specific mutations in genes that are important in the development of osteoblast or osteoclast lineages alter bone density, and (3) the linkeage of known polymorphisms for genes involved in mineral homeostasis to bone density and/or fracture. Future therapeutics for improving peak bone density or delaying bone loss later in life may take advantage of the genetic nature of bone density development.

  6. Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning

    NASA Technical Reports Server (NTRS)

    Charles, Jr., Harry K. (Inventor); Beck, Thomas J. (Inventor); Feldmesser, Howard S. (Inventor); Magee, Thomas C. (Inventor)

    2007-01-01

    Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.

  7. Collar Osteophytes Mimicking Osteonecrosis in Planar Bone Scintigraphy and Usefulness of SPECT/CT Images.

    PubMed

    Juang, Jr-Jian; Chen, Yi-Hsing; Tsai, Shih-Chuan; Lin, Wan-Yu

    2017-03-01

    The use of prednisolone is one major risk factor for osteonecrosis in patients with systemic lupus erythematosus. Bone scintigraphy can be a diagnostic tool for early diagnosis. We present a case who had collar osteophytes at the bilateral femoral heads, which mimicked osteonecrosis in the planar bone scintigram. An SPECT/CT scan avoided this pitfall and increased the diagnostic accuracy for osteonecrosis.

  8. [Evaluation of multiple myeloma with bone scintigraphy using Tc 99 diphosphonate. Review of the literature].

    PubMed

    Solis, O J; Gonzales, R; De Luca, S; McKusick, K A; Potsaid, M S

    1977-04-01

    Bone Scanning using 99m Tc-Diphosphonate is another diagnostic modality in the evaluation of multiple mieloma which allows the identification of bone lesions not demonstrable by conventional radiography. The use of 99m Tc-Diphosphonate is more convenient and less harmful than other radioactive isotopes utilized before.

  9. Usefulness of bone marrow imaging in childhood malignancies

    SciTech Connect

    Oseas, R.S.; Siddiqui, A.R.; Wellman, H.N.; Baehner, R.L.

    1982-08-01

    Two hundred six /sup 99m/Tc sulfur colloid bone marrow scans in 110 pediatrics patients were reviewed. The normal distribution of sulfur colloid in the lower extremities in various age groups was established. There was progressive loss of uptake with increasing age from less than two years to greater than ten years. Tumor replacement was seen as regions of decreased radioactivity, and the extent of the scan defect paralleled the response of the disease to therapy. Both chemotherapy and irradiation resulted in an extension of the /sup 99m/Tc SC to peripheral marrow sites. In irradiated areas, marrow scan defects were demonstrated and generally recovered normal activity by six months after the completion of therapy. Marrow scan abnormalities caused by tumor replacement were present in four patients despite normal bone scans and radiographs. Ultimate confirmation of tumor involvement was by needle aspiration or biopsy. Persistent marrow defects were seen in two patients with neuroblastoma who had remission of their disease: biopsy revealed myelofibrosis. /sup 99m/Tc sulfur colloid bone marrow scanning is a sensitive monitor of altered marrow activity associated with pediatric hematologic or oncologic diseases.

  10. Lung Ventilation/Perfusion Scan

    MedlinePlus

    ... Scan Lung VQ Scan Related Topics Arrhythmia Cough Deep Vein Thrombosis Pulmonary Embolism Send a link to NHLBI to someone by ... this topic. Related reading Chest X Ray Cough Deep Vein Thrombosis Pulmonary Embolism Rate This Content: Updated: December 9, 2016 Twitter ...

  11. Utility of Computed Tomography Scans in Predicting Need for Surgery in Nasal Injuries

    PubMed Central

    Peterson, Benjamin E.; Doerr, Timothy D.

    2013-01-01

    In many centers, computed tomography (CT) scan is preferred over plain film radiographs in the setting of acute nasal injury because CT scan is thought to be more sensitive in predicting nasal bone fracture. However, the usefulness of CT scans in predicting the need for surgery in acute nasal injury has not been well-studied. We conducted a retrospective review of 232 patients with known nasal bone fracture and found very similar rates of surgery in patients with a diagnosis of nasal fracture by CT scan as by nasal radiographs (41 and 37%, respectively). This suggests that experienced clinical examination remains the gold standard for determining the need for surgery in isolated nasal trauma, regardless of CT findings. PMID:24436764

  12. Biomaterials and bone mechanotransduction

    NASA Technical Reports Server (NTRS)

    Sikavitsas, V. I.; Temenoff, J. S.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)

    2001-01-01

    Bone is an extremely complex tissue that provides many essential functions in the body. Bone tissue engineering holds great promise in providing strategies that will result in complete regeneration of bone and restoration of its function. Currently, such strategies include the transplantation of highly porous scaffolds seeded with cells. Prior to transplantation the seeded cells are cultured in vitro in order for the cells to proliferate, differentiate and generate extracellular matrix. Factors that can affect cellular function include the cell-biomaterial interaction, as well as the biochemical and the mechanical environment. To optimize culture conditions, good understanding of these parameters is necessary. The new developments in bone biology, bone cell mechanotransduction, and cell-surface interactions are reviewed here to demonstrate that bone mechanotransduction is strongly influenced by the biomaterial properties.

  13. Biophotonics and Bone Biology

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory; Fischer, David; Asipauskas, Marius; Chauhan, Chirag; Compitello, Nicole; Burke, Jamie; Tate, Melissa Knothe

    2004-01-01

    One of the more-serious side effects of extended space flight is an accelerated bone loss [Bioastronautics Critical Path Roadmap, http://research.hq.nasa.gov/code_u/bcpr/index.cfm]. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It shows that an extrapolation of the microgravity induced bone loss rates to longer time scales, such as a 2.5 year round-trip to Mars (6 months out at 0 g, 1.5 year stay on Mars at 0.38 g, 6 months back at 0 g), could severely compromise the skeletal system of such a person.

  14. Biomaterials and bone mechanotransduction.

    PubMed

    Sikavitsas, V I; Temenoff, J S; Mikos, A G

    2001-10-01

    Bone is an extremely complex tissue that provides many essential functions in the body. Bone tissue engineering holds great promise in providing strategies that will result in complete regeneration of bone and restoration of its function. Currently, such strategies include the transplantation of highly porous scaffolds seeded with cells. Prior to transplantation the seeded cells are cultured in vitro in order for the cells to proliferate, differentiate and generate extracellular matrix. Factors that can affect cellular function include the cell-biomaterial interaction, as well as the biochemical and the mechanical environment. To optimize culture conditions, good understanding of these parameters is necessary. The new developments in bone biology, bone cell mechanotransduction, and cell-surface interactions are reviewed here to demonstrate that bone mechanotransduction is strongly influenced by the biomaterial properties.

  15. An interchangeable scanning Hall probe/scanning SQUID microscope

    SciTech Connect

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  16. The value of brain scanning

    PubMed Central

    Riddoch, D.; Drolc, Z.

    1972-01-01

    Over a 3-year period, 667 brain scans were performed, of which the results in 632 have been analysed. Positive scans were found in 68% of 204 cerebral tumours. There was a high rate of detection of meningiomas and malignant gliomas. Scanning was less helpful in visualizing slowly growing gliomas, and those tumours situated in the mid-line or posterior fossa. Metastases occupied an intermediate position. Positive scans occurred in a proportion of patients following acute cerebro-vascular accidents, and in a few other miscellaneous disorders. Virtually all patients with transient cerebral ischaemia, migraine, epilepsy and presenile dementia had normal brain scans. The value and limitations of this investigation have been discussed. PMID:5076491

  17. Investigation into mechanical properties of bone and its main constituents

    NASA Astrophysics Data System (ADS)

    Evdokimenko, Ekaterina

    Bone is a hierarchically structured natural composite material, consisting of organic phase (type-I collagen), inorganic phase (hydroxyapatite), and water. Studies of the two main bone constituents, utilizing controlled demineralization and deproteinization, can shed light on mineral-collagen interaction which makes bone such a unique biological material. This knowledge is necessary for computational analysis of bone structure to identify preferential sites in the collagen matrix and mineral network that degrade more easily. The main goal of this work is to develop a comprehensive picture of mechanical properties of bone and its main constituents. Following the Introduction, Chapter 2 presents an investigation of microstructure and compressive mechanical properties of bovine femur cortical bone carried out on completely demineralized, completely deproteinized, and untreated bone samples in three anatomical directions. Anisotropic nature of bone was clearly identified in all cases. Extra levels of porosity along with microstructural differences for the three directions were found to be the main sources of the anisotropy. In Chapter 3, a new theoretical model of cortical and trabecular bone as composite materials with hierarchical structure spanning from nanometer (collagen-mineral) level to millimeter (bone) level was developed. Compression testing was performed on untreated, demineralized, and deproteinized cortical and trabecular bovine femur bone samples to verify the model. The experimental data were compared with theoretical predictions; excellent agreement was found between the theory and experiments for all bone phases. Optical microscopy, scanning electron microscopy, and micro-computed tomography techniques were applied to characterize the structure of the samples at multiple length scales and provide further inputs for the modeling. Chapter 4 presents a comparative study of mechanical properties, microstructure, and porosity of mature and young bovine

  18. A female pelvic bone shape model for air/bone separation in support of synthetic CT generation for radiation therapy

    NASA Astrophysics Data System (ADS)

    Liu, Lianli; Cao, Yue; Fessler, Jeffrey A.; Jolly, Shruti; Balter, James M.

    2016-01-01

    Separating bone from air in MR data is one of the major challenges in using MR images to derive synthetic CT. The problem is further complicated when the anatomic regions filled with air are altered across scans due to air mobility, for instance, in pelvic regions, thereby the air regions estimated using an ultrashort echo time (UTE) sequence are invalid in other image series acquired for multispectral classification. This study aims to develop and investigate a female pelvic bone shape model to identify low intensity regions in MRI where air is unlikely to be present in support of synthetic CT generation without UTE imaging. CT scans of 30 patients were collected for the study, 17 of them also have corresponding MR scans. The shape model was built from the CT dataset, where the reference image was aligned to each of the training images using B-spline deformable registration. Principal component analysis was performed on B-spline coefficients for a compact model where shape variance was described by linear combination of principal modes. The model was applied to identify pelvic bone in MR images by deforming the corresponding MR data of the reference image to target MR images, where the search space of the deformation process was constrained within the subspace spanned by principal modes. The local minima in the search space were removed effectively by the shape model, thus supporting an efficient binary search for the optimal solution. We evaluated the model by its efficacy in identifying bone voxels and excluding air regions. The model was tested across the 17 patients that have corresponding MR scans using a leave-one-out cross validation. A simple model using the first leading principal mode only was found to achieve reasonable accuracy, where an averaged 87% of bone voxels were correctly identified. Finally dilation of the optimally fit bone mask by 5 mm was found to cover 96% of bone voxels while minimally impacting the overlap with air (below 0.4%).

  19. Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study

    PubMed Central

    He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu

    2015-01-01

    The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold. PMID:26380018

  20. Rapid prototyping for tissue-engineered bone scaffold by 3D printing and biocompatibility study.

    PubMed

    He, Hui-Yu; Zhang, Jia-Yu; Mi, Xue; Hu, Yang; Gu, Xiao-Yu

    2015-01-01

    The prototyping of tissue-engineered bone scaffold (calcined goat spongy bone-biphasic ceramic composite/PVA gel) by 3D printing was performed, and the biocompatibility of the fabricated bone scaffold was studied. Pre-designed STL file was imported into the GXYZ303010-XYLE 3D printing system, and the tissue-engineered bone scaffold was fabricated by 3D printing using gel extrusion. Rabbit bone marrow stromal cells (BMSCs) were cultured in vitro and then inoculated to the sterilized bone scaffold obtained by 3D printing. The growth of rabbit BMSCs on the bone scaffold was observed under the scanning electron microscope (SEM). The effect of the tissue-engineered bone scaffold on the proliferation and differentiation of rabbit BMSCs using MTT assay. Universal testing machine was adopted to test the tensile strength of the bone scaffold. The leachate of the bone scaffold was prepared and injected into the New Zealand rabbits. Cytotoxicity test, acute toxicity test, pyrogenic test and intracutaneous stimulation test were performed to assess the biocompatibility of the bone scaffold. Bone scaffold manufactured by 3D printing had uniform pore size with the porosity of about 68.3%. The pores were well interconnected, and the bone scaffold showed excellent mechanical property. Rabbit BMSCs grew and proliferated on the surface of the bone scaffold after adherence. MTT assay indicated that the proliferation and differentiation of rabbit BMSCs on the bone scaffold did not differ significantly from that of the cells in the control. In vivo experiments proved that the bone scaffold fabricated by 3D printing had no acute toxicity, pyrogenic reaction or stimulation. Bone scaffold manufactured by 3D printing allows the rabbit BMSCs to adhere, grow and proliferate and exhibits excellent biomechanical property and high biocompatibility. 3D printing has a good application prospect in the prototyping of tissue-engineered bone scaffold.

  1. Adrenal gland and bone.

    PubMed

    Hardy, Rowan; Cooper, Mark S

    2010-11-01

    The adrenal gland synthesizes steroid hormones from the adrenal cortex and catecholamines from the adrenal medulla. Both cortisol and adrenal androgens can have powerful effects on bone. The overproduction of cortisol in Cushing's disease leads to a dramatic reduction in bone density and an increase risk of fracture. Overproduction of adrenal androgens in congenital adrenal hyperplasia (CAH) leads to marked changes in bone growth and development with early growth acceleration but ultimately a significant reduction in final adult height. The role of more physiological levels of glucocorticoids and androgens on bone metabolism is less clear. Cortisol levels measured in elderly individuals show a weak correlation with measures of bone density and change in bone density over time with a high cortisol level associated with lower bone density and more rapid bone loss. Cortisol levels and the dynamics of cortisol secretion change with age which could also explain some age related changes in bone physiology. It is also now clear that adrenal steroids can be metabolized within bone tissue itself. Local synthesis of cortisol within bone from its inactive precursor cortisone has been demonstrated and the amount of cortisol produced within osteoblasts appears to increase with age. With regard to adrenal androgens there is a dramatic reduction in levels with aging and several studies have examined the impact that restoration of these levels back to those seen in younger individuals has on bone health. Most of these studies show small positive effects in women, not men, but the skeletal sites where benefits are seen varies from study to study.

  2. Nanocomposites and bone regeneration

    NASA Astrophysics Data System (ADS)

    James, Roshan; Deng, Meng; Laurencin, Cato T.; Kumbar, Sangamesh G.

    2011-12-01

    This manuscript focuses on bone repair/regeneration using tissue engineering strategies, and highlights nanobiotechnology developments leading to novel nanocomposite systems. About 6.5 million fractures occur annually in USA, and about 550,000 of these individual cases required the application of a bone graft. Autogenous and allogenous bone have been most widely used for bone graft based therapies; however, there are significant problems such as donor shortage and risk of infection. Alternatives using synthetic and natural biomaterials have been developed, and some are commercially available for clinical applications requiring bone grafts. However, it remains a great challenge to design an ideal synthetic graft that very closely mimics the bone tissue structurally, and can modulate the desired function in osteoblast and progenitor cell populations. Nanobiomaterials, specifically nanocomposites composed of hydroxyapatite (HA) and/or collagen are extremely promising graft substitutes. The biocomposites can be fabricated to mimic the material composition of native bone tissue, and additionally, when using nano-HA (reduced grain size), one mimics the structural arrangement of native bone. A good understanding of bone biology and structure is critical to development of bone mimicking graft substitutes. HA and collagen exhibit excellent osteoconductive properties which can further modulate the regenerative/healing process following fracture injury. Combining with other polymeric biomaterials will reinforce the mechanical properties thus making the novel nano-HA based composites comparable to human bone. We report on recent studies using nanocomposites that have been fabricated as particles and nanofibers for regeneration of segmental bone defects. The research in nanocomposites, highlight a pivotal role in the future development of an ideal orthopaedic implant device, however further significant advancements are necessary to achieve clinical use.

  3. A technique for developing CAD geometry of long bones using clinical CT data.

    PubMed

    Davis, Matthew L; Vavalle, Nicholas A; Stitzel, Joel D; Gayzik, F Scott

    2015-11-01

    Computed tomography scans are a valuable tool for developing computational models of bones. The objective of this study is to present a method to generate CAD representations of long bones from clinically based CT scans. A secondary aim is to apply the method to six long bones from a sample of three individuals. Periosteal and endosteal bone surfaces were segmented and used to calculate the characteristic cortical thickness, Tc, at 1 mm increments along the bone axis. In the epiphyses where the value of Tc fell below the scanner threshold, the endosteal bone layer was replaced using literature values projected inward from the periosteal surface. On average, 74.7 ± 7.4% of the bone geometry was above the scanner cut-off and was therefore derived from the CT scan data. The thickness measurement was also compared to experimental measurements of cadaveric bone and was found to predict Tc with an error of 3.1%. This method presents a possible solution for the characterization of characteristic thickness along the length of the bone and may also aid in the development of orthopedic implant design and subject specific finite element models.

  4. Aging and Bone

    PubMed Central

    Boskey, A.L.; Coleman, R.

    2010-01-01

    Bones provide mechanical and protective function, while also serving as housing for marrow and a site for regulation of calcium ion homeostasis. The properties of bones do not remain constant with age; rather, they change throughout life, in some cases improving in function, but in others, function deteriorates. Here we review the modifications in the mechanical function and shape of bones, the bone cells, the matrix they produce, and the mineral that is deposited on this matrix, while presenting recent theories about the factors leading to these changes. PMID:20924069

  5. Biophotonics and Bone Biology

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory; Fischer, David; Asipauskas, Marius; Chauhan, Chirag; Compitello, Nicole; Burke, Jamie; Tate, Melissa Knothe

    2004-01-01

    One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

  6. Autoinflammatory bone diseases.

    PubMed

    Stern, Sara M; Ferguson, Polly J

    2013-11-01

    Autoinflammatory bone disease is a new branch of autoinflammatory diseases caused by seemingly unprovoked activation of the innate immune system leading to an osseous inflammatory process. The inflammatory bone lesions in these disorders are characterized by chronic inflammation that is typically culture negative with no demonstrable organism on histopathology. The most common autoinflammatory bone diseases in childhood include chronic nonbacterial osteomyelitis (CNO), synovitis, acne, pustulosis, hyperostosis, osteitis syndrome, Majeed syndrome, deficiency of interleukin-1 receptor antagonist, and cherubism. In this article, the authors focus on CNO and summarize the distinct genetic autoinflammatory bone syndromes.

  7. Method for fusing bone

    DOEpatents

    Mourant, J.R.; Anderson, G.D.; Bigio, I.J.; Johnson, T.M.

    1996-03-12

    The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  8. Bone fractal analysis.

    PubMed

    Feltrin, Gian Pietro; Stramare, Roberto; Miotto, Diego; Giacomini, Dario; Saccavini, Claudio

    2004-06-01

    Fractal analysis is a quantitative method used to evaluate complex anatomic findings in their elementary component. Its application to biologic images, particularly to cancellous bones, has been well practiced within the past few years. The aims of these applications are to assess changes in bone and the loss of spongious architecture, indicate bone fragility, and to show the increased risk for fracture in primary or secondary osteoporosis. The applications are very promising to help complete the studies that can define bone density (bone mineral density by dual energy x-ray absorptiometry or quantitative computed tomography), and also have the capacity to distinguish the patients with a high or low risk for fracture. Their extension to the clinical fields, to define a test for fracture risk, is still limited by difficult application to the medical quantitative imaging of bones, between correct application at superficial bones and unreliable application to deep bones. The future evolution and validity do not depend upon fractal methods but upon well-detailed imaging of the bones in clinical conditions.

  9. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects.

    PubMed

    Van der Stok, Johan; Van der Jagt, Olav P; Amin Yavari, Saber; De Haas, Mirthe F P; Waarsing, Jan H; Jahr, Holger; Van Lieshout, Esther M M; Patka, Peter; Verhaar, Jan A N; Zadpoor, Amir A; Weinans, Harrie

    2013-05-01

    Porous titanium scaffolds have good mechanical properties that make them an interesting bone substitute material for large bone defects. These scaffolds can be produced with selective laser melting, which has the advantage of tailoring the structure's architecture. Reducing the strut size reduces the stiffness of the structure and may have a positive effect on bone formation. Two scaffolds with struts of 120-µm (titanium-120) or 230-µm (titanium-230) were studied in a load-bearing critical femoral bone defect in rats. The defect was stabilized with an internal plate and treated with titanium-120, titanium-230, or left empty. In vivo micro-CT scans at 4, 8, and 12 weeks showed more bone in the defects treated with scaffolds. Finally, 18.4 ± 7.1 mm(3) (titanium-120, p = 0.015) and 18.7 ± 8.0 mm(3) (titanium-230, p = 0.012) of bone was formed in those defects, significantly more than in the empty defects (5.8 ± 5.1 mm(3) ). Bending tests on the excised femurs after 12 weeks showed that the fusion strength reached 62% (titanium-120) and 45% (titanium-230) of the intact contralateral femurs, but there was no significant difference between the two scaffolds. This study showed that in addition to adequate mechanical support, porous titanium scaffolds facilitate bone formation, which results in high mechanical integrity of the treated large bone defects.

  10. Final Report: Bone Mass Inheritance: A Project to Identify the Genetic Regulation of Bone Mass

    SciTech Connect

    Recker, Robert R., M.D.

    2002-03-28

    This project was designed to find human chromosomal locations that contain genes regulating peak bone density. It is part of a whole genome search for those loci,each responsible for at least 15% of the variation in the peak adult bone density. We accomplished this with a sib pair design, combined with simultaneous examination of extended kindreds. This project gave partial support of the recruitment which has now been completed. The project will extend into 2003. During the remainder of the project, a whole genome scan will be performed from the entire cohort of 2226 persons who have DNA archived, followed by linkage analysis. This project will meet the scientific objective leading eventually to expanded options for treating the condition that leads to bone thinning osteoporosis, and potential fractures in aging populations.

  11. Rotary ultrasonic bone drilling: Improved pullout strength and reduced damage.

    PubMed

    Gupta, Vishal; Pandey, Pulak M; Silberschmidt, Vadim V

    2017-03-01

    Bone drilling is one of the most common operations used to repair fractured parts of bones. During a bone drilling process, microcracks are generated on the inner surface of the drilled holes that can detrimentally affect osteosynthesis and healing. This study focuses on the investigation of microcracks and pullout strength of cortical-bone screws in drilled holes. It compares conventional surgical bone drilling (CSBD) with rotary ultrasonic bone drilling (RUBD), a novel approach employing ultrasonic vibration with a diamond-coated hollow tool. Both techniques were used to drill holes in porcine bones in an in-vitro study. Scanning electron microscopy was used to observe microcracks and surface morphology. The results obtained showed a significant decrease in the number and dimensions of microcracks generated on the inner surface of drilled holes with the RUBD process in comparison to CSBD. It was also observed that a higher rotational speed and a lower feed rate resulted in lower damage, i.e. fewer microcracks. Biomechanical axial pullout strength of a cortical bone screw inserted into a hole drilled with RUBD was found to be much higher (55-385%) than that for CSBD.

  12. Equine cortical bone exhibits rising R-curve fracture mechanics.

    PubMed

    Malik, C L; Stover, S M; Martin, R B; Gibeling, J C

    2003-02-01

    Previous studies of the fracture properties of cortical bone have suggested that the fracture toughness increases with crack length, which is indicative of rising R-curve behavior. Based on this indirect evidence and the similarity of bone to ceramic matrix composites, we hypothesized that bone would exhibit rising R-curve behavior in the transverse orientation and that the characteristics of the R-curves would be regionally dependent within the cortex due to variations in bone microstructure and toughening mechanisms. To test these hypotheses, we conducted R-curve experiments on specimens from equine third metacarpal bones using standard fracture mechanics testing methods. Compact type specimens from the dorsal and lateral regions in the middle of the diaphysis were oriented for crack propagation transverse to the longitudinal axis of the bone. The test results demonstrate that equine cortical bone exhibits rising R-curve behavior during transverse crack propagation as hypothesized. Statistical analyses of the crack growth initiation toughness, K0, the peak toughness, Kpeak, and the crack extension at peak toughness, deltaa, revealed significant regional differences in these characteristics. Specifically, the lateral cortex displayed higher crack growth initiation and peak toughnesses. The dorsal cortex exhibited greater crack extension at the peak of crack growth resistance. Scanning electron microscopy revealed osteon pullout on fracture surfaces from the dorsal cortex and but not in the lateral cortex. Taken together, the significant differences in R-curves and the SEM fractography indicate that the fracture mechanisms acting in equine cortical bone are regionally dependent.

  13. Re-scan confocal microscopy: scanning twice for better resolution

    PubMed Central

    De Luca, Giulia M.R.; Breedijk, Ronald M.P.; Brandt, Rick A.J.; Zeelenberg, Christiaan H.C.; de Jong, Babette E.; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A.; Stallinga, Sjoerd; Manders, Erik M.M.

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required. PMID:24298422

  14. 3D Scan Systems Integration

    DTIC Science & Technology

    2007-11-02

    AGENCY USE ONLY (Leave Blank) 2. REPORT DATE 5 Feb 98 4. TITLE AND SUBTITLE 3D Scan Systems Integration REPORT TYPE AND DATES COVERED...2-89) Prescribed by ANSI Std. Z39-1 298-102 [ EDO QUALITY W3PECTEDI DLA-ARN Final Report for US Defense Logistics Agency on DDFG-T2/P3: 3D...SCAN SYSTEMS INTEGRATION Contract Number SPO100-95-D-1014 Contractor Ohio University Delivery Order # 0001 Delivery Order Title 3D Scan Systems

  15. Circular Scan Streak Tube Development

    NASA Technical Reports Server (NTRS)

    Nevin, S.

    1980-01-01

    A streak tube having circular scan was designed, built and tested. Continuous circular scan, easily derived from out of phase sine waves applied to the conventional deflection plates, permits the timing of pulses traveling long baselines. At the tube's output a circular array of 720 elements is scanned to provide 30 to 40 picosecond resolution. Initial difficulties with electron bombarded silicon arrays were circumvented by using microchannel plates within the streak tube to provide the needed electronic amplification and digital sensitivity and coupling the 720 element arrays to the electron beam by means of a phosphor on a fiber optics. Two ceramic body tubes with S-20 photocathodes were tested and delivered.

  16. Horizontal bone augmentation by means of guided bone regeneration.

    PubMed

    Benic, Goran I; Hämmerle, Christoph H F

    2014-10-01

    The development of bone augmentation procedures has allowed placement of dental implants into jaw bone areas lacking an amount of bone sufficient for standard implant placement. Thus, the indications for implants have broadened to include jaw regions with bone defects and those with a bone anatomy that is unfavorable for implant anchorage. Of the different techniques, the best documented and the most widely used method to augment bone in localized alveolar defects is guided bone regeneration. A large body of evidence has demonstrated the successful use of guided bone regeneration to regenerate missing bone at implant sites with insufficient bone volume and the long-term success of implants placed simultaneously with, or after, guided bone regeneration. However, the influence of guided bone regeneration on implant survival and success rates, and the long-term stability of the augmented bone, remain unknown. Many of the materials and techniques currently available for bone regeneration of alveolar ridge defects were developed many years ago. Recently, various new materials and techniques have been introduced. Many of them have, however, not been sufficiently documented in clinical studies. The aim of this review was to present the scientific basis of guided bone regeneration and the accepted clinical procedures. A classification of bone defects has been presented, aiming at simplifying the decision-making process regarding the choice of strategy for bone augmentation. Finally, an outlook into actual research and the possible future options related to bone augmentation has been provided.

  17. Exercise, lifestyle, and your bones

    MedlinePlus

    Osteoporosis - exercise; Low bone density - exercise; Osteopenia - exercise ... To build up bone density, the exercise must make your muscles pull on your bones. These are called weight-bearing exercises. Some of them are: ...

  18. Children's Bone Health and Calcium

    MedlinePlus

    ... Research Information Clinical Trials Resources and Publications Children's Bone Health and Calcium: Condition Information Skip sharing on ... media links Share this: Page Content What is bone health and how do you build strong bones? ...

  19. Exercise for Your Bone Health

    MedlinePlus

    ... supported by your browser. Home Bone Basics Lifestyle Exercise for Your Bone Health Publication available in: PDF ( ... A Complete Osteoporosis Program For Your Information Why Exercise? Like muscle, bone is living tissue that responds ...

  20. PHYSICOCHEMICAL CHARACTERIZATION OF LYOPHILIZED BOVINE BONE GRAFTS

    PubMed Central

    Galia, Carlos Roberto; Lourenço, André Luis; Rosito, Ricardo; Souza Macedo, Carlos Alberto; Camargo, Lourdes Maria Araujo Quaresma

    2015-01-01

    To evaluate the physicochemical characteristics of lyophilized bovine grafts manufactured on a semi-industrial scale (Orthogen; Baumer S/A*) in accordance with a protocol previously developed by the authors. Methods: The lyophilized bovine bone grafts were characterized by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffractometry (XRD), thermogravimetric (TG) analysis, differential exploratory scanning calorimetry (DSC) and Fourier-transform infrared (FT-IR) spectroscopy. Results: Ca was the main component (60%) found in the samples, followed by P (28%) and O (5%). The mean (sd) pore size was 316 μm (146.7), ranging from 91.2 to 497.8 μm, and 333.5 μm (304.8), ranging from 87.2 to 963.9 μm, at 50x and 150x magnification, respectively. The hydroxyapatite peaks were at 26°C and 32°C, and mass losses were observed between 250°C and 640°C, corresponding to organic material and water. Two temperature transitions (45.67°C and 91.89°C) showed denaturation of type 1 collagen and dehydration of hydroxyapatite. Conclusion: The physicochemical assessment of lyophilized bovine bone grafts in accordance with the protocol developed at semi-industrial scale confirmed that this product presents excellent biocompatibility, with characteristics similar to natural bone. PMID:27027036

  1. Coating with a Modular Bone Morphogenetic Peptide Promotes Healing of a Bone-Implant Gap in an Ovine Model

    PubMed Central

    Lu, Yan; Lee, Jae Sung; Nemke, Brett; Graf, Ben K.; Royalty, Kevin; Illgen, Richard; Vanderby, Ray; Markel, Mark D.; Murphy, William L.

    2012-01-01

    Despite the potential for growth factor delivery strategies to promote orthopedic implant healing, there is a need for growth factor delivery methods that are controllable and amenable to clinical translation. We have developed a modular bone growth factor, herein termed “modular bone morphogenetic peptide (mBMP)”, which was designed to efficiently bind to the surface of orthopedic implants and also stimulate new bone formation. The purpose of this study was to coat a hydroxyapatite-titanium implant with mBMP and evaluate bone healing across a bone-implant gap in the sheep femoral condyle. The mBMP molecules efficiently bound to a hydroxyapatite-titanium implant and 64% of the initially bound mBMP molecules were released in a sustained manner over 28 days. The results demonstrated that the mBMP-coated implant group had significantly more mineralized bone filling in the implant-bone gap than the control group in C-arm computed tomography (DynaCT) scanning (25% more), histological (35% more) and microradiographic images (50% more). Push-out stiffness of the mBMP group was nearly 40% greater than that of control group whereas peak force did not show a significant difference. The results of this study demonstrated that mBMP coated on a hydroxyapatite-titanium implant stimulates new bone formation and may be useful to improve implant fixation in total joint arthroplasty applications. PMID:23185610

  2. Tantalum coating of porous carbon scaffold supplemented with autologous bone marrow stromal stem cells for bone regeneration in vitro and in vivo.

    PubMed

    Wei, Xiaowei; Zhao, Dewei; Wang, Benjie; Wang, Wei; Kang, Kai; Xie, Hui; Liu, Baoyi; Zhang, Xiuzhi; Zhang, Jinsong; Yang, Zhenming

    2016-03-01

    Porous tantalum metal with low elastic modulus is similar to cancellous bone. Reticulated vitreous carbon (RVC) can provide three-dimensional pore structure and serves as the ideal scaffold of tantalum coating. In this study, the biocompatibility of domestic porous tantalum was first successfully tested with bone marrow stromal stem cells (BMSCs) in vitro and for bone tissue repair in vivo. We evaluated cytotoxicity of RVC scaffold and tantalum coating using BMSCs. The morphology, adhesion, and proliferation of BMSCs were observed via laser scanning confocal microscope and scanning electron microscopy. In addition, porous tantalum rods with or without autologous BMSCs were implanted on hind legs in dogs, respectively. The osteogenic potential was observed by hard tissue slice examination. At three weeks and six weeks following implantation, new osteoblasts and new bone were observed at the tantalum-host bone interface and pores. At 12 weeks postporous tantalum with autologous BMSCs implantation, regenerated trabecular equivalent to mature bone was found in the pore of tantalum rods. Our results suggested that domestic porous tantalum had excellent biocompatibility and could promote new bone formation in vivo. Meanwhile, the osteogenesis of porous tantalum associated with autologous BMSCs was more excellent than only tantalum implantation. Future clinical studies are warranted to verify the clinical efficacy of combined implantation of this domestic porous tantalum associated with autologous BMSCs implantation and compare their efficacy with conventional autologous bone grafting carrying blood vessel in patients needing bone repairing.

  3. Tantalum coating of porous carbon scaffold supplemented with autologous bone marrow stromal stem cells for bone regeneration in vitro and in vivo

    PubMed Central

    Wei, Xiaowei; Wang, Benjie; Wang, Wei; Kang, Kai; Xie, Hui; Liu, Baoyi; Zhang, Xiuzhi; Zhang, Jinsong; Yang, Zhenming

    2016-01-01

    Porous tantalum metal with low elastic modulus is similar to cancellous bone. Reticulated vitreous carbon (RVC) can provide three-dimensional pore structure and serves as the ideal scaffold of tantalum coating. In this study, the biocompatibility of domestic porous tantalum was first successfully tested with bone marrow stromal stem cells (BMSCs) in vitro and for bone tissue repair in vivo. We evaluated cytotoxicity of RVC scaffold and tantalum coating using BMSCs. The morphology, adhesion, and proliferation of BMSCs were observed via laser scanning confocal microscope and scanning electron microscopy. In addition, porous tantalum rods with or without autologous BMSCs were implanted on hind legs in dogs, respectively. The osteogenic potential was observed by hard tissue slice examination. At three weeks and six weeks following implantation, new osteoblasts and new bone were observed at the tantalum–host bone interface and pores. At 12 weeks postporous tantalum with autologous BMSCs implantation, regenerated trabecular equivalent to mature bone was found in the pore of tantalum rods. Our results suggested that domestic porous tantalum had excellent biocompatibility and could promote new bone formation in vivo. Meanwhile, the osteogenesis of porous tantalum associated with autologous BMSCs was more excellent than only tantalum implantation. Future clinical studies are warranted to verify the clinical efficacy of combined implantation of this domestic porous tantalum associated with autologous BMSCs implantation and compare their efficacy with conventional autologous bone grafting carrying blood vessel in patients needing bone repairing. PMID:26843518

  4. The limitation of DEXA analysis for bone mass determination in mice.

    PubMed

    Dickson, Glenn R; Luczak, Mirosław; Włodarski, Krzysztof H

    2004-01-01

    An increase in femoral and tibio/fibular bone mass following periosteal membrane stimulation by Moloney sarcoma virus inoculation into thigh muscles of mice was measured in situ on formalin fixed excised hind limbs using a Hologic 4500A Fan Beam X-ray bone densitometer adapted for small bone samples. These results were verified by measurements of constant dry bone mass of the same bones liberated from soft limb tissues by NaOH hydrolysis. There was no consistent data correlation found between the DEXA scan and dry bone mass evaluations. It is concluded that the sensitivity of the DEXA measurement is unsuitable when assessing very small bone samples, weighing merely 20-30 mg.

  5. Primary Ewing Sarcoma of Sphenoid Bone with Intracranial Extension: A Common Tumour at an Uncommon Location

    PubMed Central

    Singh, Guddi Rani; Choudhary, Vijayanand

    2017-01-01

    Primary Ewing Sarcoma of the cranial bone is rare, contributing to only 1% of all Ewing Sarcomas. Primary cranial Ewing Sarcoma occurs most commonly in temporal bone followed by parietal and occipital bones. Sphenoid bone is less commonly involved. We report a case of Ewing Sarcoma of the sphenoid bone with intra-cranial extension in a 20-month-old boy. On CT scan a provisional diagnosis of rhabdomyosarcoma was made. Fine Needle Aspiration Cytology (FNAC) and histopathological examination of core needle biopsy showed small round cell tumour. On Immunohistochemistry (IHC), CD99 (MIC2) and FLI 1 were strongly positive and final diagnosis of Ewing Sarcoma was made. Considering the rarity of this unusual site, we report a case of primary Ewing Sarcoma arising in the sphenoid bone with erosion of adjacent bones and intra-cranial extension. PMID:28384876

  6. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    SciTech Connect

    Sty, J.; Simons, G.

    1982-05-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success.

  7. Biodegradable synthetic bone composites

    SciTech Connect

    Liu, Gao; Zhao, Dacheng; Saiz, Eduardo; Tomsia, Antoni P.

    2013-01-01

    The invention provides for a biodegradable synthetic bone composition comprising a biodegradable hydrogel polymer scaffold comprising a plurality of hydrolytically unstable linkages, and an inorganic component; such as a biodegradable poly(hydroxyethylmethacrylate)/hydroxyapatite (pHEMA/HA) hydrogel composite possessing mineral content approximately that of human bone.

  8. Automated trabecular bone histomorphometry

    NASA Technical Reports Server (NTRS)

    Polig, E.; Jee, W. S. S.

    1985-01-01

    The toxicity of alpha-emitting bone-seeking radionuclides and the relationship between bone tumor incidence and the local dosimetry of radionuclides in bone are investigated. The microdistributions of alpha-emitting radionuclides in the trabecular bone from the proximal humerus, distal humerus, proximal ulna, proximal femur, and distal femur of six young adult beagles injected with Am-241 (three with 2.8 micro-Ci/kg and three with 0.9 micro-Ci/kg) are estimated using a computer-controlled microscope photometer system; the components of the University of Utah Optical Track Scanner are described. The morphometric parameters for the beagles are calculated and analyzed. It is observed that the beagles injected with 0.9 micro-Ci of Am-241/kg showed an increase in the percentage of bone and trabecular bone thickness, and a reduction in the width of the bone marrow space and surface/volume ratio. The data reveal that radiation damage causes abnormal bone structure.

  9. BONES, TEACHER'S GUIDE.

    ERIC Educational Resources Information Center

    Elementary Science Study, Newton, MA.

    THIS GUIDE WAS DEVELOPED FOR USE WITH THE ELEMENTARY SCIENCE STUDY UNIT ON "BONES.""BONES" HAS BEEN TAUGHT IN THE FOURTH GRADE AND REQUIRES FROM 10 TO 25 LESSONS, DEPENDING ON THE NUMBER OF ACTIVITIES USED. THE GUIDE DOES NOT PROVIDE DETAILED INSTRUCTION FOR CONDUCTING CLASSES, BUT RATHER SOME POSSIBLE ACTIVITIES, AND LEAVES…

  10. Osteocyte and bone structure.

    PubMed

    Klein-Nulend, Jenneke; Nijweide, Peter J; Burger, Elisabeth H

    2003-06-01

    The osteocyte is the most abundant cell type of bone. There are approximately 10 times as many osteocytes as osteoblasts in adult human bone, and the number of osteoclasts is only a fraction of the number of osteoblasts. Our current knowledge of the role of osteocytes in bone metabolism is far behind our insight into the properties and functions of the osteoblasts and osteoclasts. However, the striking structural design of bone predicts an important role for osteocytes in determining bone structure. Over the past several years, the role of osteocytes as the professional mechanosensory cells of bone, and the lacunocanalicular porosity as the structure that mediates mechanosensing have become clear. Strain-derived flow of interstitial fluid through this porosity seems to mechanically activate the osteocytes, as well as ensure transport of cell signaling molecules, nutrients, and waste products. This concept explains local bone gain and loss--as well as remodeling in response to fatigue damage--as processes supervised by mechanosensitive osteocytes. Alignment during remodeling seems to occur as a result of the osteocyte's sensing different canalicular flow patterns around the cutting cone and reversal zone during loading, therefore determining the bone's structure.

  11. Transverse section radionuclide scanning system

    DOEpatents

    Kuhl, David E.; Edwards, Roy Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three-dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program.

  12. Studies in Scanning Probe Microscopy.

    DTIC Science & Technology

    2007-11-02

    refereed journals, as well as two books titled Scanning Force Microscopy, With Applications to Electric, Magnetic, and Atomic Forces published by Oxford University Press in 1991 and a revised edition in 1994.

  13. Retinal locus for scanning text.

    PubMed

    Timberlake, George T; Sharma, Manoj K; Grose, Susan A; Maino, Joseph H

    2006-01-01

    A method of mapping the retinal location of text during reading is described in which text position is plotted cumulatively on scanning laser ophthalmoscope retinal images. Retinal locations that contain text most often are the brightest in the cumulative plot, and locations that contain text least often are the darkest. In this way, the retinal area that most often contains text is determined. Text maps were plotted for eight control subjects without vision loss and eight subjects with central scotomas from macular degeneration. Control subjects' text maps showed that the fovea contained text most often. Text maps of five of the subjects with scotomas showed that they used the same peripheral retinal area to scan text and fixate. Text maps of the other three subjects with scotomas showed that they used separate areas to scan text and fixate. Retinal text maps may help evaluate rehabilitative strategies for training individuals with central scotomas to use a particular retinal area to scan text.

  14. Liver echinococcus - CT scan (image)

    MedlinePlus

    This upper abdominal CT scan shows multiple cysts in the liver, caused by dog tapeworm (echinococcus). Note the large circular cyst (seen on the left side of the screen) and multiple smaller cysts throughout ...

  15. Bone-seeking radiopharmaceuticals as targeted agents of osteosarcoma: samarium-153-EDTMP and radium-223.

    PubMed

    Anderson, Peter M; Subbiah, Vivek; Rohren, Eric

    2014-01-01

    Osteosarcoma is a cancer characterized by formation of bone by malignant cells. Routine bone scan imaging with Tc-99m-MDP is done at diagnosis to evaluate primary tumor uptake and check for bone metastases. At time of relapse the Tc-99m-MDP bone scan also provides a specific means to assess formation of bone by malignant osteosarcoma cells and the potential for bone-seeking radiopharmaceuticals to deliver radioactivity directly into osteoblastic osteosarcoma lesions. This chapter will review and compare a bone-seeking radiopharmaceutical that emits beta-particles, samarium-153-EDTMP, with an alpha-particle emitter, radium-223. The charged alpha particles from radium-223 have far more mass and energy than beta particles (electrons) from Sm-153-EDTMP. Because radium-223 has less marrow toxicity and more radiobiological effectiveness, especially if inside the bone forming cancer cell than samarium-153-EDTMP, radium-223 may have greater potential to become widely used against osteosarcoma as a targeted therapy. Radium-223 also has more potential to be used with chemotherapy against osteosarcoma and bone metastases. Because osteosarcoma makes bone and radium-223 acts like calcium, this radiopharmaceutical could possibly become a new targeted means to achieve safe and effective reduction of tumor burden as well as facilitate better surgery and/or radiotherapy for difficult to resect large, or metastatic tumors.

  16. Peripheral quantitative computed tomography (pQCT) for the assessment of bone strength in most of bone affecting conditions in developmental age: a review.

    PubMed

    Stagi, Stefano; Cavalli, Loredana; Cavalli, Tiziana; de Martino, Maurizio; Brandi, Maria Luisa

    2016-09-26

    Peripheral quantitative computed tomography provides an automatical scan analysis of trabecular and cortical bone compartments, calculating not only their bone mineral density (BMD), but also bone geometrical parameters, such as marrow and cortical Cross-Sectional Area (CSA), Cortical Thickness (CoTh), both periosteal and endosteal circumference, as well as biomechanical parameters like Cross-Sectional Moment of Inertia (CSMI), a measure of bending, polar moment of inertia, indicating bone strength in torsion, and Strength Strain Index (SSI). Also CSA of muscle and fat can be extracted. Muscles, which are thought to stimulate bones to adapt their geometry and mineral content, are determinant to preserve or increase bone strength; thus, pQCT provides an evaluation of the functional 'muscle-bone unit', defined as BMC/muscle CSA ratio. This functional approach to bone densitometry can establish if bone strength is normally adapted to the muscle force, and if muscle force is adequate for body size, providing more detailed insights to targeted strategies for the prevention and treatment of bone fragility. The present paper offers an extensive review of technical features of pQCT and its possible clinical application in the diagnostic of bone status as well as in the monitoring of the skeleton's health follow-up.

  17. [Metabolic bone diseases].

    PubMed

    Jakob, F

    2007-10-01

    Osteomalacia is caused by impaired vitamin D receptor (VDR) signaling, calcium deficiency, and altered bone mineralization. This can be due to insufficient sunlight exposure, malabsorption, reduced D hormone activation in chronic kidney disease, and rare alterations of VDR signaling and phosphate metabolism. Leading symptoms are bone pain, muscular cramps, and increased incidence of falls in the elderly. The adequate respective countermeasures are to optimize the daily intake of calcium and vitamin D3 and to replace active D hormone and phosphate if deficient. Osteoporosis is characterized by bone fragility fractures upon minor physical impact. Indications for diagnosis and treatment can be established by estimating the absolute fracture risk, taking into account bone mineral density, age, gender, and individual risk factors. Exercise, intervention programs to avoid falls, and specific drugs are capable of substantially reducing fracture risk even in the elderly. Secondary osteoporosis primarily requires both bone-altering medications and effective treatment of underlying diseases.

  18. Bone and Celiac Disease.

    PubMed

    Zanchetta, María Belén; Longobardi, Vanesa; Bai, Julio César

    2016-04-01

    More than 50% of untreated patients with celiac disease (CD) have bone loss detected by bone densitometry (dual-energy X-ray absorptiometry:DXA). Moreover, patients with CD are more likely to have osteoporosis and fragility fractures, especially of the distal radius. Although still controversial, we recommend DXA screening in all celiac disease patients, particularly in those with symptomatic CD at diagnosis and in those who present risk factors for fracture such as older age, menopausal status, previous fracture history, and familial hip fracture history. Bone microarchitecture, especially the trabecular network, may be deteriorated, explaining the higher fracture risk in these patients. Adequate calcium and vitamin D supplementation are also recommended to optimize bone recovery, especially during the first years of gluten free diet (GFD). If higher fracture risk persists after 1 or 2 years of GFD, specific osteoactive treatment may be necessary to improve bone health.

  19. Ultrasonic bone densitometer

    NASA Technical Reports Server (NTRS)

    Hoop, J. M. (Inventor)

    1974-01-01

    A device, for measuring the density of a bone structure so as to monitor the calcium content, is described. A pair of opposed spaced ultrasonic transducers are held within a clamping apparatus closely adjacent the bone being analyzed. These ultrasonic transducers incude piezoelectric crystals shaped to direct signals through the bone encompassed in the heel and finger of the subject being tested. A pulse generator is coupled to one of the transducers and generates an electric pulse for causing the transducers to generate an ultrasonic sound wave which is directed through the bone structure to the other transducer. An electric circuit, including an amplifier and a bandpass filter couples the signals from the receiver transducer back to the pulse generator for retriggering the pulse generator at a frequency proportional to the duration that the ultrasonic wave takes to travel through the bone structure being examined.

  20. Scanned Laser Illuminator/Receiver

    DTIC Science & Technology

    1976-11-01

    illustrate parallel development of the PIN diode /CCD sensor hybrid and the 100W laser . Al- though a detailed cost analysis for procurement of this large...pmww^^W .m^n.m .,** ■ —ssa^ AFAL-TR-76-184 \\ SCANNED LASER ILLUMINATOR/RECEIVER ^ R. A. Honzik and F. B. Warren ^•Martin Marietta...NUMBER 4. TITLE (and Sublille) SCANNED LASER ILLUMINATOR/RECEIVER 5, TYPE OF REPORT & PERIOD COVERED Final Technical Report Dec 75