Science.gov

Sample records for 30-day flow test

  1. Research on regulating technique of material flow for 2-person and 30-day integrated CELSS test

    NASA Astrophysics Data System (ADS)

    Guo, Shuangsheng; Dong, Wenping; Ai, Weidang; Feng, Hongqi; Tang, Yongkang; Huang, Zhide; Shen, Yunze; Ren, Jin; Qin, Lifeng; Zeng, Gu; Zhang, Lihong; Zhu, Jingtao; Fei, Jinxue; Xu, Guoxin

    2014-07-01

    A man-plant integration test was processed using the CELSS integration experiment platform in which 4 kinds of plants were grown (Lactuca sativa L var. Dasusheng, L. sativa L var. Youmaicai, Gynura bicolor and Cichorium endivia L) to exchange material with 2 persons in order to research the dynamic changing laws and balanced regulation of air and water between man and plant in an inclosed system. In the test the material flow was measured so that the dynamically changing laws and balanced regulation of air and water between man and plant in the closed system were mostly mastered. The material closure degree of air, water and food reached 100%, 90% and 13.9% respectively with the whole system closure degree up to 95.1%. Meanwhile, it was proved that a 13.5 m2 planting area could meet the demand of one person for O2 in the system, and the energy efficiency ratio of which reached 59.56 g/(kW m2 day). The material flow dynamic balance-regulating technology was initially mastered between man and plant through the test. The interaction was realized among man, plant and environment in the closed system, which is of great significance to the advancement of long-term manned environment control and life support technology for China.

  2. Study on the kinetic characteristics of trace harmful gases for a two-person-30-day integrated CELSS test.

    PubMed

    Guo, Shuangsheng; Ai, Weidang; Fei, Jinxue; Xu, Guoxin; Zeng, Gu; Shen, Yunze

    2015-05-01

    A two-person-30-day controlled ecological life support system (CELSS) integrated test was carried out, and more than 30 kinds of trace harmful gases including formaldehyde, benzene, and ammonia were measured and analyzed dynamically. The results showed that the kinds and quantities of the trace harmful gases presented a continuously fluctuating state during the experimental period, but none of them exceed the spacecraft maximum allowable concentration (SMAC). The results of the Pre-Test (with two persons without plants for 3 days) and the Test (with two persons and four kinds of plants for 30 days) showed that there are some notable differences for the compositions of the trace harmful gases; the volatile organic compounds (VOCs) such as toluene, hexane, and acetamide were searched out in the Pre-Test, but were not found in the Test. Moreover, the concentrations of the trace harmful gases such as acetic benzene, formaldehyde, and ammonia decreased greatly in the Test more than those in the Pre-Test, which means that the plants can purify these gases efficiently. In addition, the VOCs such as carbon monoxide, cyclopentane, and dichloroethylene were checked out in the Test but none in the Pre-Test, which indicates that these materials might be from the crew's metabolites or those devices in the platform. Additionally, the ethylene released specially by plants accumulated in the later period and its concentration reached nearly ten times of 0.05 mg m(-3) (maximum allowed concentration for plant growth, which must have promoted the later withering of plants). We hoped that the work can play a referring function for controlling VOCs effectively so that future more CELSS integrating tests can be implemented smoothly with more crew, longer period, and higher closure. PMID:25483969

  3. Study on the Dynamically Changing Law of Trace Contaminants for the 2-person-30-day Integrated CELSS Test

    NASA Astrophysics Data System (ADS)

    Guo, Shuangsheng

    A 2-person-30-day Integrated CELSS Test was carried out recently, and more than 30 kinds of trace contaminants including formaldehyde, benzene and ammonia were measured and analyzed dynamically. The results showed that the kinds and quantities of trace contaminants presented a continuously fluctuating state during the experimental period, but all of them didn’t exceed the SMAC. The results of the pre-test (with 2 persons without plants for 3 days) and the formal test (with 2 persons and 4 kinds of plants for 30 days) showed that there are some notable differences for the compositions of the trace contaminants; the volatile organic compounds (VOCs) such as toluene, hexane and acetamide were searched out in the pre-test, but couldn’t be found in the formal test. Moreover, the concentrations of the trace gases such as acetic benzene, formaldehyde and ammonia decreased greatly in the formal test more than them in the pre-test, which means that the plants can purified these gases efficiently. In addition, the VOCs such as carbon monoxide, cyclopentane and dichloroethylene were checked out in the formal test but none in the pre-test, which means that these materials might be from cabin facilities or human metabolites. Additionally, the ethylene released specially by plants accumulated in the later period and its concentration reached nearly 10 times of MAC (50ppb), which must have promoted the earlier wane of plants. It’s hoped that the work can play a referring function for future more CELSS integrating test with more persons, longer time and higher material closure.

  4. Study on the kinetic characteristics of trace harmful gases for a two-person-30-day integrated CELSS test.

    PubMed

    Guo, Shuangsheng; Ai, Weidang; Fei, Jinxue; Xu, Guoxin; Zeng, Gu; Shen, Yunze

    2015-05-01

    A two-person-30-day controlled ecological life support system (CELSS) integrated test was carried out, and more than 30 kinds of trace harmful gases including formaldehyde, benzene, and ammonia were measured and analyzed dynamically. The results showed that the kinds and quantities of the trace harmful gases presented a continuously fluctuating state during the experimental period, but none of them exceed the spacecraft maximum allowable concentration (SMAC). The results of the Pre-Test (with two persons without plants for 3 days) and the Test (with two persons and four kinds of plants for 30 days) showed that there are some notable differences for the compositions of the trace harmful gases; the volatile organic compounds (VOCs) such as toluene, hexane, and acetamide were searched out in the Pre-Test, but were not found in the Test. Moreover, the concentrations of the trace harmful gases such as acetic benzene, formaldehyde, and ammonia decreased greatly in the Test more than those in the Pre-Test, which means that the plants can purify these gases efficiently. In addition, the VOCs such as carbon monoxide, cyclopentane, and dichloroethylene were checked out in the Test but none in the Pre-Test, which indicates that these materials might be from the crew's metabolites or those devices in the platform. Additionally, the ethylene released specially by plants accumulated in the later period and its concentration reached nearly ten times of 0.05 mg m(-3) (maximum allowed concentration for plant growth, which must have promoted the later withering of plants). We hoped that the work can play a referring function for controlling VOCs effectively so that future more CELSS integrating tests can be implemented smoothly with more crew, longer period, and higher closure.

  5. Preventing 30-day readmissions.

    PubMed

    Stevens, Sherri

    2015-03-01

    Preventing 30-day readmissions to hospitals is a top priority in the era of health care reform. New regulations will be costly to health care facilities because of payment guidelines. The most frequently readmitted medical conditions are acute myocardial infarction, heart failure, and pneumonia. The transition from the hospital and into the home has been classified as a vulnerable time for many patients. During this time of transition patients may fail to fully understand their discharge instructions. Ineffective communication, low health literacy, and compliance issues contribute to readmissions. Telehealth and the use of technology may be used to prevent some readmissions.

  6. Methods for estimating magnitude and frequency of 1-, 3-, 7-, 15-, and 30-day flood-duration flows in Arizona

    USGS Publications Warehouse

    Kennedy, Jeffrey R.; Paretti, Nicholas V.; Veilleux, Andrea G.

    2014-01-01

    Regression equations, which allow predictions of n-day flood-duration flows for selected annual exceedance probabilities at ungaged sites, were developed using generalized least-squares regression and flood-duration flow frequency estimates at 56 streamgaging stations within a single, relatively uniform physiographic region in the central part of Arizona, between the Colorado Plateau and Basin and Range Province, called the Transition Zone. Drainage area explained most of the variation in the n-day flood-duration annual exceedance probabilities, but mean annual precipitation and mean elevation were also significant variables in the regression models. Standard error of prediction for the regression equations varies from 28 to 53 percent and generally decreases with increasing n-day duration. Outside the Transition Zone there are insufficient streamgaging stations to develop regression equations, but flood-duration flow frequency estimates are presented at select streamgaging stations.

  7. 76 FR 17734 - 30-Day Notice of Proposed Information Collection: Form DS-1998E, Foreign Service Officer Test...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... Notice of Proposed Information Collection: Form DS-1998E, Foreign Service Officer Test Registration Form... the Paperwork Reduction Act of 1995. Title of Information Collection: Foreign Service Officer Test... Foreign Service Officer Test. Estimated Number of Respondents: 30,000. Estimated Number of Responses:...

  8. Ares I-X 30 Day Report

    NASA Technical Reports Server (NTRS)

    Ess, Bob; Smith, Marshall

    2009-01-01

    This slide presentation represents the 30 day report on the Ares I-X test flight. Included in the review is information on the following areas: (1) Ground Systems, (2) Guidance, Navigation and Control, (3) Roll Response, (4) Vehicle Response, (5) Control System Performance, (6) Structural Damping, (7) Thrust Oscillation, (8) Stage Separation, (9) Connector Assessment, (10) USS Splashdown, (11) Data Recorder and (12) FS Hardware Assessment.

  9. Reducing 30-day Readmission After Joint Replacement.

    PubMed

    Chambers, Monique C; El-Othmani, Mouhanad M; Anoushiravani, Afshin A; Sayeed, Zain; Saleh, Khaled J

    2016-10-01

    Hospital readmission is a focus of quality measures used by the Center for Medicare and Medicaid (CMS) to evaluate quality of care. Policy changes provide incentives and enforce penalties to decrease 30-day hospital readmissions. CMS implemented the Readmission Penalty Program. Readmission rates are being used to determine reimbursement rates for physicians. The need for readmission is deemed an indication for inadequate quality of care subjected to financial penalties. This reviews identifies risk factors that have been significantly associated with higher readmission rates, addresses approaches to minimize 30-day readmission, and discusses the potential future direction within this area as regulations evolve.

  10. Reducing 30-day Readmission After Joint Replacement.

    PubMed

    Chambers, Monique C; El-Othmani, Mouhanad M; Anoushiravani, Afshin A; Sayeed, Zain; Saleh, Khaled J

    2016-10-01

    Hospital readmission is a focus of quality measures used by the Center for Medicare and Medicaid (CMS) to evaluate quality of care. Policy changes provide incentives and enforce penalties to decrease 30-day hospital readmissions. CMS implemented the Readmission Penalty Program. Readmission rates are being used to determine reimbursement rates for physicians. The need for readmission is deemed an indication for inadequate quality of care subjected to financial penalties. This reviews identifies risk factors that have been significantly associated with higher readmission rates, addresses approaches to minimize 30-day readmission, and discusses the potential future direction within this area as regulations evolve. PMID:27637653

  11. 75 FR 45121 - Agency Information Collection Request; 30-Day Public Comment Request; 30-Day Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency Information Collection Request; 30-Day Public Comment Request; 30-Day Notice... Paperwork Reduction Act of 1995, the Office of the Secretary (OS), Department of Health and Human...

  12. Shuttle flight experiment 30-day summary report

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A total of 12 AFT training sessions were administered to SL 3 Payload Specialists over a 7 month period. Nine of these sessions were 2 hours in duration and three were 3 hours in duration. A total of three rotating chair tests were conducted in this time frame with four subjects. The performance of these crewmen across tests is shown. Test 1, a baseline motion sickness test, was conducted approximately 10 months prior to the mission, before any AFT was administered. Test 2 was administered after 2 hours of AFT, test 3 after 4 hours and test 4 after 6 hours (total) of training in symptom control. Improvement in performance is reflected by a subject's ability to tolerate a greater number of rotations across tests. Additional training for crewman was not possible within the constraints of the mission. Results of the mission indicate that, as predicted preflight, subject #32 was relatively symptom free inflight while subject #33 was not. Other preflight and postflight tests and analyses are reported.

  13. Effect of feeding in 30-day bioaccumulation assays using Hyalella azteca in fluoranthene-dosed sediment

    SciTech Connect

    Harkey, G.A.; Landrum, P.F.

    1995-12-31

    Current protocols for conducting freshwater sediment bioaccumulation tests require that food be added to exposures. To determine effects of adding food, 30-day bioaccumulation assays were conducted with H. azteca exposed to sediment dosed with four concentrations (0.05 to 1,267 nmol/g dry weight) of fluoranthene. Accumulation was significantly greater in fed versus non-fed animals at all dose levels after 96 and 240 hours of exposure and continued to be greater after 30 days in the low dose levels. At sediment concentrations above 634 nmol/g dw, survival of unfed animals dropped to 34% after 30 days, However, after 30 days, reproduction was observed in fed animals exposed to sediment concentrations > 16 times the expected LC50 calculated for fluoranthene in sediment. These data raise questions concerning the interpretation of standard toxicity and bioaccumulation tests when food is routinely added.

  14. 78 FR 18373 - Paperwork Reduction Act; 30-Day Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... CONTROL POLICY Paperwork Reduction Act; 30-Day Notice AGENCY: Office of National Drug Control Policy. ] The Office of National Drug Control Policy (ONDCP) proposes the collection of information concerning... of the President, Office of National Drug Control Policy, Research & Data Analysis, Washington,...

  15. 75 FR 160 - Paperwork Reduction Act; 30-Day Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... From the Federal Register Online via the Government Publishing Office OFFICE OF NATIONAL DRUG CONTROL POLICY Paperwork Reduction Act; 30-Day Notice AGENCY: Office of National Drug Control Policy. The Office of National Drug Control Policy (ONDCP) proposes the collection of information concerning...

  16. Discharge Outcomes in Seniors Hospitalized for More than 30 Days

    ERIC Educational Resources Information Center

    Kozyrskyj, Anita; Black, Charlyn; Chateau, Dan; Steinbach, Carmen

    2005-01-01

    Hospitalization is a sentinel event that leads to loss of independence for many seniors. This study of long-stay hospitalizations (more than 30 days) in seniors was undertaken to identify risk factors for not going home, to characterize patients with risk factors who did go home and to describe one year outcomes following home discharge. Using…

  17. Nursing Home Medical Staff Organization and 30-Day Rehospitalizations

    PubMed Central

    Lima, Julie C.; Intrator, Orna; Karuza, Jurgis; Wetle, Terrie; Mor, Vincent; Katz, Paul

    2013-01-01

    Objectives To examine the relationship between features of nursing home (NH) medical staff organization and residents’ 30-day rehospitalizations. Design Cross-sectional study combining primary data collected from a survey of medical directors, NH resident assessment data (minimum data set), Medicare claims, and the Online Survey Certification and Reporting (OSCAR) database. Setting A total of 202 freestanding US nursing homes. Participants Medicare fee-for-service beneficiaries who were hospitalized and subsequently admitted to a study nursing home. Measurements Medical staff organization dimensions derived from the survey, NH residents’ characteristics derived from minimum data set data, hospitalizations obtained from Part A Medicare claims, and NH characteristics from the OSCAR database and from www.ltcfocus.org. Study outcome defined within a 30-day window following an index hospitalization: rehospitalized, otherwise died, otherwise survived and not rehospitalized. Results Thirty-day rehospitalizations occurred for 3788 (20.3%) of the 18,680 initial hospitalizations. Death was observed for 884 (4.7%) of residents who were not rehospitalized. Adjusted by hospitalization, resident, and NH characteristics, nursing homes having a more formal appointment process for physicians were less likely to have 30-day rehospitalization (b = −0.43, SE = 0.17), whereas NHs in which a higher proportion of residents were cared for by a single physician were more likely to have rehospitalizations (b = 0.18, SE = 0.08). Conclusion This is the first study to show a direct relationship between features of NH medical staff organization and resident-level process of care. The relationship of a more strict appointment process and rehospitalizations might be a consequence of more formalized and dedicated medical practice with a sense of ownership and accountability. A higher volume of patients per physician does not appear to improve quality of care. PMID:22682694

  18. Modulation of HLA-DR in dry eye patients following 30 days of treatment with a lubricant eyedrop solution

    PubMed Central

    Fernandez, Karen B; Epstein, Seth P; Raynor, Geoffrey S; Sheyman, Alan T; Massingale, Morgan L; Dentone, Peter G; Landegger, Lukas D; Asbell, Penny A

    2015-01-01

    Purpose To determine the changes in dry eye disease (DED) severity and the percentage of cells expressing HLA-DR on the ocular surface following treatment with lubricant eyedrops containing polyethylene glycol and propylene glycol (PEG/PG) and the gelling agent hydroxypropyl guar (HP-Guar). Patients and methods Nineteen patients with DED used PEG/PG + HP-Guar eyedrops four times per day for 30 days. Assessments included DED severity (Ocular Surface Disease Index [OSDI], corneal staining, conjunctival staining, tear film break-up time [TFBUT], and Schirmer testing) and impression cytology of the conjunctiva with masked flow cytometry at baseline and at 30 days. Results There was a significant decrease in corneal staining (P<0.01), OSDI (P=0.02), and TFBUT (P<0.01) following treatment with PEG/PG + HP-Guar. Results from flow cytometry revealed a significant decrease in cells expressing HLA-DR (P=0.02). Conclusion Treatment with PEG/PG + HP-Guar eyedrops showed improvement in dry eye severity and reduction in surface inflammation as indicated by a reduction in HLA-DR expression. PMID:26170605

  19. Fluorescent Particles For Flow Testing

    NASA Technical Reports Server (NTRS)

    Bonnell, Jeremy L.; Stern, Susan M.; Torkelson, Jan R.

    1995-01-01

    Small alumina spheres coated with fluorescent dye used in flow testing of transparent plastic model of check valve. Entrained fluroescent particles make flows visible. After completion of flow test, particles remaining in valve easily detectable and removed for measurement of their sizes.

  20. Long-term (30 days) toxicity of NiO nanoparticles for adult zebrafish Danio rerio

    PubMed Central

    Kovrižnych, Jevgenij A.; Zeljenková, Dagmar; Rollerová, Eva; Szabová, Elena

    2014-01-01

    Nickel oxide in the form of nanoparticles (NiO NPs) is extensively used in different industrial branches. In a test on adult zebrafish, the acute toxicity of NiO NPs was shown to be low, however longlasting contact with this compound can lead to its accumulation in the tissues and to increased toxicity. In this work we determined the 30-day toxicity of NiO NPs using a static test for zebrafish Danio rerio. We found the 30-day LC50 value to be 45.0 mg/L, LC100 (minimum concentration causing 100% mortality) was 100.0 mg/L, and LC0 (maximum concentration causing no mortality) was 6.25 mg/L for adult individuals of zebrafish. Considering a broad use of Ni in the industry, NiO NPs chronic toxicity may have a negative impact on the population of aquatic organisms and on food web dynamics in aquatic systems. PMID:26038672

  1. Carotid baroreflex response following 30 days exposure to simulated microgravity

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Doerr, D. F.; Eckberg, D. L.; Fritsch, J. M.; Vernikos-Danellis, J.

    1989-01-01

    The mechanism of the carotid-baroreflex response to weightlessness was investigated in human subjects exposed to simulated microgravity (30 days of 6-day head-down bed rest followed by 5 days of recovery). Baroreceptor-cardiac reflex responses were elicited by a complex sequence of pressure changes delivered to a neck chamber device. The shape of the sigmoid baroreceptor-cardiac response curve was examined for alterations and the occurrence of resetting, as well as for a possible association of the impaired baroreflex function with hypotension during the postexposure orthostatic stress. It was found that the exposure to head-down bed rest caused a significant shift on the R-R interval axis, which paralleled reductions and elevations in baseline HR such that the baseline R-R (operational point) remained in the same position on the response curve. This shift in the location of the reflex relation indicates a significant resetting of the carotid baroreceptors, which may represent an appropriate adaptation which contributes to the maintenance of a constant resting arterial blood pressure before, during, and after bed rest, observed in these study.

  2. Analysis of flow reversal test

    SciTech Connect

    Cheng, L.Y.; Tichler, P.R.

    1996-03-01

    A series of tests has been conducted to measure the dryout power associated with a flow transient whereby the coolant in a heated channel undergoes a change in flow direction. An analysis of the test was made with the aid of a system code, RELAP5. A dryout criterion was developed in terms of a time-averaged void fraction calculated by RELAP5 for the heated channel. The dryout criterion was also compared with several CHF correlations developed for the channel geometry.

  3. Capillary flow solder wettability test

    SciTech Connect

    Vianco, P.T.; Rejent, J.A.

    1996-01-01

    A test procedure was developed to assess the capillary flow wettability of solders inside of a confined geometry. The test geometry was comprised of two parallel plates with a controlled gap of constant thickness (0.008 cm, 0.018 cm, 0.025 cm, and 0.038 cm). Capillary flow was assessed by: (1) the meniscus or capillary rise of the solder within the gap, (2) the extent of void formation in the gap, and (3) the time-dependence of the risen solder film. Tests were performed with the lead-free solders.

  4. Changes in size and compliance of the calf after 30 days of simulated microgravity

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Doerr, Donald F.; Stein, Stewart L.

    1989-01-01

    The hypothesis that reducing muscle compartment by a long-term exposure to microgravity would cause increased leg venous compliance was tested in eight men who were assessed for vascular compliance and for serial circumferences of the calf before and after 30 days of continuous 6-deg head-down bed rest. It was found that head-down bed rest caused decreases in the calculated calf volume and the calf-muscle compartment, as well as increases in calf compliance. The percent increases in calf compliance correlated significantly with decreases in calf muscle compartment.

  5. Development of Lightweight Material Composites to Insulate Cryogenic Tanks for 30-Day Storage in Outer Space

    NASA Technical Reports Server (NTRS)

    Krause, D. R.

    1972-01-01

    A conceptual design was developed for an MLI system which will meet the design constraints of an ILRV used for 7- to 30-day missions. The ten tasks are briefly described: (1) material survey and procurement, material property tests, and selection of composites to be considered; (2) definition of environmental parameters and tooling requirements, and thermal and structural design verification test definition; (3) definition of tanks and associated hardware to be used, and definition of MLI concepts to be considered; (4) thermal analyses, including purge, evacuation, and reentry repressurization analyses; (5) structural analyses (6) thermal degradation tests of composite and structural tests of fastener; (7) selection of MLI materials and system; (8) definition of a conceptual MLI system design; (9) evaluation of nondestructive inspection techniques and definition of procedures for repair of damaged areas; and (10) preparation of preliminary specifications.

  6. 78 FR 21160 - Paperwork Reduction Act; 30-Day Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ... instruments used in the production of ONDCP's National Youth Anti-Drug Media Campaign advertising and Media Campaign advertising tracking. Purpose: The National Youth Anti-Drug Media Campaign is in the process of... (or ``focus group'') testing of creative advertising concepts (OMB 3201-0011),...

  7. Inpatient Readmissions and Emergency Department Visits within 30 Days of a Hospital Admission

    PubMed Central

    Brennan, Jesse J.; Chan, Theodore C.; Killeen, James P.; Castillo, Edward M.

    2015-01-01

    Introduction Inpatient hospital readmissions have become a focus for healthcare reform and cost-containment efforts. Initiatives targeting unanticipated readmissions have included care coordination for specific high readmission diseases and patients and health coaching during the post-discharge transition period. However, little research has focused on emergency department (ED) visits following an inpatient admission. The objective of this study was to assess 30-day ED utilization and all-cause readmissions following a hospital admission. Methods This was a retrospective study using inpatient and ED utilization data from two hospitals with a shared patient population in 2011. We assessed the 30-day ED visit rate and 30-day readmission rate and compared patient characteristics among individuals with 30-day inpatient readmissions, 30-day ED discharges, and no 30-day visits. Results There were 13,449 patients who met the criteria of an index visit. Overall, 2,453 (18.2%) patients had an ED visit within 30 days of an inpatient stay. However, only 55.6% (n=1,363) of these patients were admitted at one of these 30-day visits, resulting in a 30-day all-cause readmission rate of 10.1%. Conclusion Approximately one in five patients presented to the ED within 30 days of an inpatient hospitalization and over half of these patients were readmitted. Readmission measures that incorporate ED visits following an inpatient stay might better inform interventions to reduce avoidable readmissions. PMID:26759647

  8. Correspondence between hair cortisol concentrations and 30-day integrated daily salivary and weekly urinary cortisol measures.

    PubMed

    Short, Sarah J; Stalder, Tobias; Marceau, Kristine; Entringer, Sonja; Moog, Nora K; Shirtcliff, Elizabeth A; Wadhwa, Pathik D; Buss, Claudia

    2016-09-01

    Characterization of cortisol production, regulation and function is of considerable interest and relevance given its ubiquitous role in virtually all aspects of physiology, health and disease risk. The quantification of cortisol concentration in hair has been proposed as a promising approach for the retrospective assessment of integrated, long-term cortisol production. However, human research is still needed to directly test and validate current assumptions about which aspects of cortisol production and regulation are reflected in hair cortisol concentrations (HCC). Here, we report findings from a validation study in a sample of 17 healthy adults (mean±SD age: 34±8.6 yrs). To determine the extent to which HCC captures cumulative cortisol production, we examined the correspondence of HCC, obtained from the first 1cm scalp-near hair segment, assumed to retrospectively reflect 1-month integrated cortisol secretion, with 30-day average salivary cortisol area-under-the curve (AUC) based on 3 samples collected per day (on awakening, +30min, at bedtime) and the average of 4 weekly 24-h urinary free cortisol (UFC) assessments. To further address which aspects of cortisol production and regulation are best reflected in the HCC measure, we also examined components of the salivary measures that represent: (1) production in response to the challenge of awakening (using the cortisol awakening response [CAR]), and (2) chronobiological regulation of cortisol production (using diurnal slope). Finally, we evaluated the test-retest stability of each cortisol measure. Results indicate that HCC was most strongly associated with the prior 30-day integrated cortisol production measure (average salivary cortisol AUC) (r=0.61, p=0.01). There were no significant associations between HCC and the 30-day summary measures using CAR or diurnal slope. The relationship between 1-month integrated 24-h UFC and HCC did not reach statistical significance (r=0.30, p=0.28). Lastly, of all cortisol

  9. Correspondence between hair cortisol concentrations and 30-day integrated daily salivary and weekly urinary cortisol measures.

    PubMed

    Short, Sarah J; Stalder, Tobias; Marceau, Kristine; Entringer, Sonja; Moog, Nora K; Shirtcliff, Elizabeth A; Wadhwa, Pathik D; Buss, Claudia

    2016-09-01

    Characterization of cortisol production, regulation and function is of considerable interest and relevance given its ubiquitous role in virtually all aspects of physiology, health and disease risk. The quantification of cortisol concentration in hair has been proposed as a promising approach for the retrospective assessment of integrated, long-term cortisol production. However, human research is still needed to directly test and validate current assumptions about which aspects of cortisol production and regulation are reflected in hair cortisol concentrations (HCC). Here, we report findings from a validation study in a sample of 17 healthy adults (mean±SD age: 34±8.6 yrs). To determine the extent to which HCC captures cumulative cortisol production, we examined the correspondence of HCC, obtained from the first 1cm scalp-near hair segment, assumed to retrospectively reflect 1-month integrated cortisol secretion, with 30-day average salivary cortisol area-under-the curve (AUC) based on 3 samples collected per day (on awakening, +30min, at bedtime) and the average of 4 weekly 24-h urinary free cortisol (UFC) assessments. To further address which aspects of cortisol production and regulation are best reflected in the HCC measure, we also examined components of the salivary measures that represent: (1) production in response to the challenge of awakening (using the cortisol awakening response [CAR]), and (2) chronobiological regulation of cortisol production (using diurnal slope). Finally, we evaluated the test-retest stability of each cortisol measure. Results indicate that HCC was most strongly associated with the prior 30-day integrated cortisol production measure (average salivary cortisol AUC) (r=0.61, p=0.01). There were no significant associations between HCC and the 30-day summary measures using CAR or diurnal slope. The relationship between 1-month integrated 24-h UFC and HCC did not reach statistical significance (r=0.30, p=0.28). Lastly, of all cortisol

  10. Continuous 30-day measurements utilizing the monkey metabolism pod. [study of weightlessness effects

    NASA Technical Reports Server (NTRS)

    Pace, N.; Kodama, A. M.; Mains, R. C.; Rahlmann, D. F.; Grunbaum, B. W.

    1977-01-01

    A fiberglass system was previously described, using which quantitative physiological measurements could be made to study the effects of weightlessness on 10 to 14 kg adult monkeys maintained in comfortable restraint under space flight conditions. Recent improvements in the system have made it possible to obtain continuous measurements of respiratory gas exchange, cardiovascular function, and mineral balance for periods of up to 30 days on pig-tailed monkeys. It has also been possible to operate two pods which share one set of instrumentation, thereby permitting simultaneous measurements to be made on two animals by commutating signal outputs from the pods. In principle, more than two pods could be operated in this fashion. The system is compatible with Spacelab design. Representative physiological data from ground tests of the system are presented.

  11. 17 CFR 41.12 - Indexes underlying futures contracts trading for fewer than 30 days.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... contracts trading for fewer than 30 days. 41.12 Section 41.12 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION SECURITY FUTURES PRODUCTS Narrow-Based Security Indexes § 41.12 Indexes underlying futures contracts trading for fewer than 30 days. (a) An index on which a contract of sale...

  12. 78 FR 65695 - 30-Day Notice of Proposed Information Collection: Technical Processing Requirements for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    .... ACTION: Correction, notice. SUMMARY: On October 25, 2013 at 78 FR 64146 HUD published a 30 day notice of... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Technical Processing Requirements..., Department of Housing and Urban Development, 451 7th Street SW., Washington, DC 20410; email Colette...

  13. 19 CFR 158.42 - Abandonment by importer within 30 days after entry.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 2 2014-04-01 2014-04-01 false Abandonment by importer within 30 days after entry..., OR EXPORTED Destroyed, Abandoned, or Exported Merchandise § 158.42 Abandonment by importer within 30... written notice of abandonment with the director of the port where the entry was filed within 30 days...

  14. 19 CFR 158.42 - Abandonment by importer within 30 days after entry.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 2 2011-04-01 2011-04-01 false Abandonment by importer within 30 days after entry..., OR EXPORTED Destroyed, Abandoned, or Exported Merchandise § 158.42 Abandonment by importer within 30... written notice of abandonment with the director of the port where the entry was filed within 30 days...

  15. 19 CFR 158.42 - Abandonment by importer within 30 days after entry.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 2 2013-04-01 2013-04-01 false Abandonment by importer within 30 days after entry..., OR EXPORTED Destroyed, Abandoned, or Exported Merchandise § 158.42 Abandonment by importer within 30... written notice of abandonment with the director of the port where the entry was filed within 30 days...

  16. 19 CFR 158.42 - Abandonment by importer within 30 days after entry.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 2 2012-04-01 2012-04-01 false Abandonment by importer within 30 days after entry..., OR EXPORTED Destroyed, Abandoned, or Exported Merchandise § 158.42 Abandonment by importer within 30... written notice of abandonment with the director of the port where the entry was filed within 30 days...

  17. 19 CFR 158.42 - Abandonment by importer within 30 days after entry.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Abandonment by importer within 30 days after entry..., OR EXPORTED Destroyed, Abandoned, or Exported Merchandise § 158.42 Abandonment by importer within 30... which the merchandise being abandoned appears. (b) Application within 30 days. The importer shall...

  18. 77 FR 48160 - Division of Cardiovascular Devices 30-Day Notices and Annual Reports; Public Workshop; Request...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... HUMAN SERVICES Food and Drug Administration Division of Cardiovascular Devices 30-Day Notices and Annual... following public workshop entitled ``Division of Cardiovascular Devices 30-Day Notices and Annual Reports..., specifically for cardiovascular devices. DATES: Date and Time: The public workshop will be held on August...

  19. Testing the frozen flow approximation

    NASA Technical Reports Server (NTRS)

    Lucchin, Francesco; Matarrese, Sabino; Melott, Adrian L.; Moscardini, Lauro

    1993-01-01

    We investigate the accuracy of the frozen-flow approximation (FFA), recently proposed by Matarrese, et al. (1992), for following the nonlinear evolution of cosmological density fluctuations under gravitational instability. We compare a number of statistics between results of the FFA and n-body simulations, including those used by Melott, Pellman & Shandarin (1993) to test the Zel'dovich approximation. The FFA performs reasonably well in a statistical sense, e.g. in reproducing the counts-in-cell distribution, at small scales, but it does poorly in the crosscorrelation with n-body which means it is generally not moving mass to the right place, especially in models with high small-scale power.

  20. 78 FR 52007 - 30-Day Notice of Proposed Information Collection: Financial Statement of Corporate Applicant for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Financial Statement of Corporate... Information Collection: Financial Statement of Corporate Applicant for Cooperative Housing Mortgage. OMB... information to determine feasibility, mortgagor/contractor acceptability as well as the financial data,...

  1. 78 FR 36561 - 30-Day Notice of Proposed Information Collection: The Housing Counseling Federal Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: The Housing Counseling Federal... Information Collection: The Housing Counseling Federal Advisory Committee Membership Application. OMB Approval... for the information and proposed use: The Housing Counseling Federal Advisory Committee (HCFAC)...

  2. 78 FR 40314 - 30-Day Notice of Proposed Information Collection: Fair Housing Initiatives Program Grant

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Fair Housing Initiatives Program..., 2012. A. Overview of Information Collection Title of Information Collection: Fair Housing Initiatives... approved information collection used to select applicants for the Fair Housing Initiatives Program...

  3. 78 FR 59046 - 30-Day Notice of Proposed Information Collection: Federal Labor Standards Questionnaire(s...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Federal Labor Standards..., Reports Management Officer, QDAM, Department of Housing and Urban Development, 451 7th Street...

  4. 78 FR 39001 - 30-Day Notice of Proposed Information Collection: Uniform Physical Standards and Physical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-28

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Uniform Physical Standards and Physical Inspection Requirements AGENCY: Office of the Chief Information Officer, HUD. ACTION: Notice... Information Collection: Uniform Physical Standards and Physical Inspection Requirements. OMB Approval...

  5. 78 FR 54267 - 30-Day Notice of Proposed Information Collection: Disaster Recovery Grant Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-03

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Disaster Recovery Grant Reporting..., 2013. A. Overview of Information Collection Title of Information Collection: Disaster Recovery Grant... information and proposed use: The Disaster Recovery Grant Reporting (DRGR) System is a grants...

  6. 78 FR 44579 - 30-Day Notice of Proposed Information Collection: Fellowship Placement Pilot Program Evaluation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-24

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Fellowship Placement Pilot Program.... A. Overview of Information Collection Title of Information Collection: Fellowship Placement Pilot.... Description of the need for the information and proposed use: The Fellowship Placement Program places...

  7. Utility of Socioeconomic Status in Predicting 30-Day Outcomes After Heart Failure Hospitalization

    PubMed Central

    Eapen, Zubin J.; McCoy, Lisa A.; Fonarow, Gregg C.; Yancy, Clyde W.; Miranda, Marie Lynn; Peterson, Eric D.; Califf, Robert M.; Hernandez, Adrian F.

    2015-01-01

    Background An individual's socioeconomic status (SES) is associated with health outcomes and mortality, yet it is unknown whether accounting for SES can improve risk-adjustment models for 30-day outcomes among Centers for Medicare & Medicaid Services (CMS) beneficiaries hospitalized with heart failure (HF). Methods and Results We linked clinical data on hospitalized HF patients in the Get With The Guidelines®-HF™ database (01/2005–12/2011) with CMS claims and county-level SES data from the 2012 Area Health Resources Files. We compared the discriminatory capabilities of multivariable models that adjusted for SES, patient, and/or hospital characteristics to determine whether county-level SES data improved prediction or changed hospital rankings for 30-day all-cause mortality and rehospitalization. After adjusting for patient and hospital characteristics, median household income (per $5,000 increase) was inversely associated with odds of 30-day mortality (OR 0.97, 95% CI 0.95–1.00, p=0.032), and the percentage of persons with at least a high school diploma (per 5 unit increase) was associated with lower odds of 30-day rehospitalization (OR 0.95, 95% CI 0.91–0.99).After adjustment for county-level SES data, relative to whites, Hispanic ethnicity (OR 0.70, 95% CI 0.58, 0.83) and black race (OR 0.57, 95% CI: 0.50–0.65) remained significantly associated with lower 30-day mortality, but had similar 30-day rehospitalization. County-level SES did not improve risk adjustment or change hospital rankings for 30-day mortality or rehospitalization. Conclusions County-level SES data are modestly associated with 30-day outcomes for CMS beneficiaries hospitalized with HF, but do not improve risk adjustment models based on patient characteristics alone. PMID:25747700

  8. Predictors of 30-day mortality in patients with spontaneous primary intracerebral hemorrhage

    PubMed Central

    Safatli, Diaa A.; Günther, Albrecht; Schlattmann, Peter; Schwarz, Falko; Kalff, Rolf; Ewald, Christian

    2016-01-01

    Background: Intracerebral hemorrhage (ICH) is a life threatening entity, and an early outcome assessment is mandatory for optimizing therapeutic efforts. Methods: We retrospectively analyzed data from 342 patients with spontaneous primary ICH to evaluate possible predictors of 30-day mortality considering clinical, radiological, and therapeutical parameters. We also applied three widely accepted outcome grading scoring systems [(ICH score, FUNC score and intracerebral hemorrhage grading scale (ICH-GS)] on our population to evaluate the correlation of these scores with the 30-day mortality in our study. We also applied three widely accepted outcome grading scoring systems [(ICH score, FUNC score and intracerebral hemorrhage grading scale (ICH-GS)] on our population to evaluate the correlation of these scores with the 30-day mortality in our study. Results: From 342 patients (mean age: 67 years, mean Glasgow Coma Scale [GCS] on admission: 9, mean ICH volume: 62.19 ml, most common hematoma location: basal ganglia [43.9%]), 102 received surgical and 240 conservative treatment. The 30-day mortality was 25.15%. In a multivariate analysis, GCS (Odds ratio [OR] =0.726, 95% confidence interval [CI] =0.661–0.796, P < 0.001), bleeding volume (OR = 1.012 per ml, 95% CI = 1.007 – 1.017, P < 0.001), and infratentorial hematoma location (OR = 5.381, 95% CI = 2.166-13.356, P = 0.009) were significant predictors for the 30-day mortality. After receiver operating characteristics analysis, we defined a “high-risk group” for an unfavorable short-term outcome with GCS <11 and ICH volume >32 ml supratentorially or 21 ml infratentorially. Using Pearson correlation, we found a correlation of 0.986 between ICH score and 30-day mortality (P < 0.001), 0.853 between FUNC score and 30-day mortality (P = 0.001), and 0.924 between ICH-GS and 30-day mortality (P = 0.001). Conclusions: GCS score on admission together with the baseline volume and localization of the hemorrhage are strong

  9. Analysis of rat testicular proteome following 30-day exposure to 900 MHz electromagnetic field radiation.

    PubMed

    Sepehrimanesh, Masood; Kazemipour, Nasrin; Saeb, Mehdi; Nazifi, Saeed

    2014-12-01

    The use of electromagnetic field (EMF) generating apparatuses such as cell phones is increasing, and has caused an interest in the investigations of its effects on human health. We analyzed proteome in preparations from the whole testis in adult male Sprague-Dawley rats that were exposed to 900 MHz EMF radiation for 1, 2, or 4 h/day for 30 consecutive days, simulating a range of possible human cell phone use. Subjects were sacrificed immediately after the end of the experiment and testes fractions were solubilized and separated via high-resolution 2D electrophoresis, and gel patterns were scanned, digitized, and processed. Thirteen proteins, which were found only in sham or in exposure groups, were identified by MALDI-TOF/TOF-MS. Among them, heat shock proteins, superoxide dismutase, peroxiredoxin-1, and other proteins related to misfolding of proteins and/or stress were identified. These results demonstrate significant effects of radio frequency modulated EMFs exposure on proteome, particularly in protein species in the rodent testis, and suggest that a 30-day exposure to EMF radiation induces nonthermal stress in testicular tissue. The functional implication of the identified proteins was discussed.

  10. Anastomotic leaks after colorectal anastomosis occurring more than 30 days postoperatively: a single-institution evaluation.

    PubMed

    Tan, Wei Phin; Hong, En Yaw; Phillips, Benjamin; Isenberg, Gerald A; Goldstein, Scott D

    2014-09-01

    National hospital registries only report colorectal anastomotic leaks (ALs) within 30 days postoperatively. The aim of our study was to determine the incidence and significance of ALs that occur beyond 30 days postoperatively. We performed a retrospective review of our prospective database from June 2008 to August 2012. A total of 504 patients were included. These patients were operated on by two surgeons. Any clinical or radiographic abnormalities were considered to be an anastomotic imperfection. A total of 504 patients were reviewed with a total of 18 (3.6%) anastomotic leaks. Six leaks (31.6% of leaks) were diagnosed more than 30 days postoperatively (P < 0.001). Of the 18 leaks, interventional radiology drainage was performed for four cases and 14 patients required reoperation. All six delayed leaks required reoperation. There was one leak that occurred under 30 days, which was discovered on autopsy. The median follow-up was 12 months (range, 1 to 4 months). All the delayed leak patients presented with fistulas, whereas 58 per cent of typical leak patients presented with the triad of leukocytosis, fever, and abdominal pain. Colorectal anastomotic leaks can occur after the 30-day postoperative period. In patients with vague and atypical abdominal findings, anastomotic leak must be suspected. More systematic, prospective studies are required to help us further understand the risk factors and natural history of anastomotic failures in elective colorectal surgery.

  11. Half of 30-Day Hospital Readmissions Among HIV-Infected Patients Are Potentially Preventable

    PubMed Central

    Kitchell, Ellen; Etherton, Sarah Shelby; Duarte, Piper; Halm, Ethan A.; Jain, Mamta K.

    2015-01-01

    Abstract Thirty-day readmission rates, a widely utilized quality metric, are high among HIV-infected individuals. However, it is unknown how many 30-day readmissions are preventable, especially in HIV patients, who have been excluded from prior potentially preventable readmission analyses. We used electronic medical records to identify all readmissions within 30 days of discharge among HIV patients hospitalized at a large urban safety net hospital in 2011. Two independent reviewers assessed whether readmissions were potentially preventable using both published criteria and detailed chart review, how readmissions might have been prevented, and the phase of care deemed suboptimal (inpatient care, discharge planning, post-discharge). Of 1137 index admissions, 213 (19%) resulted in 30-day readmissions. These admissions occurred among 930 unique HIV patients, with 130 individuals (14%) experiencing 30-day readmissions. Of these 130, about half were determined to be potentially preventable using published criteria (53%) or implicit chart review (48%). Not taking antiretroviral therapy (ART) greatly increased the odds of a preventable readmission (OR 5.9, CI:2.4–14.8). Most of the preventable causes of readmission were attributed to suboptimal care during the index hospitalization. Half of 30-day readmission in HIV patients are potentially preventable. Increased focus on early ART initiation, adherence counseling, management of chronic conditions, and appropriate timing of discharge may help reduce readmissions in this vulnerable population. PMID:26154066

  12. Associations between Depressive Symptoms and 30-day Hospital Readmission among Older Adults

    PubMed Central

    Berges, Ivonne M.; Amr, Sania; Abraham, Danielle S.; Cannon, Dawn L.; Ostir, Glenn V.

    2015-01-01

    Background Hospital readmissions are common and costly. Our goal was to determine the association between depressive symptoms and readmission within 30 days following hospital discharge in older adults. Methods We analyzed data from a study of 789 persons aged 65 years or older admitted to a 20-bed acute care for elders (ACE) hospital unit from May 2009 to July 2011. Depressive symptoms were recorded within 24-hours of admission to the hospital unit, using the Center for Epidemiologic Studies -Depression (CES-D) Scale. The primary outcome was readmission to hospital within 30 days of discharge. Results The mean age was 77 years; 66% were female, 72% were White, and 59% were unmarried. On average, older patients reported 2.6 comorbid conditions. Sixteen percent were classified with high depressive symptoms (CES-D ≥ 16). The readmission rate within 30 days was 15%. Older patients with high depressive symptoms had more than 1.6 times the odds (OR 1.66; 95% CI: 1.01-2.74) of being readmitted within 30-days, as compared to those with low depressive symptoms (CES-D < 16), after adjustment for age, race/ethnicity, sex, marital status and comorbid conditions. Conclusion High depressive symptoms increased the risk of hospital readmission within 30 days of discharge after adjusting for relevant covariates. In-hospital screening for depressive symptoms may identify older persons at risk for recurrent hospital admissions. PMID:27134802

  13. Half of 30-Day Hospital Readmissions Among HIV-Infected Patients Are Potentially Preventable.

    PubMed

    Nijhawan, Ank E; Kitchell, Ellen; Etherton, Sarah Shelby; Duarte, Piper; Halm, Ethan A; Jain, Mamta K

    2015-09-01

    Thirty-day readmission rates, a widely utilized quality metric, are high among HIV-infected individuals. However, it is unknown how many 30-day readmissions are preventable, especially in HIV patients, who have been excluded from prior potentially preventable readmission analyses. We used electronic medical records to identify all readmissions within 30 days of discharge among HIV patients hospitalized at a large urban safety net hospital in 2011. Two independent reviewers assessed whether readmissions were potentially preventable using both published criteria and detailed chart review, how readmissions might have been prevented, and the phase of care deemed suboptimal (inpatient care, discharge planning, post-discharge). Of 1137 index admissions, 213 (19%) resulted in 30-day readmissions. These admissions occurred among 930 unique HIV patients, with 130 individuals (14%) experiencing 30-day readmissions. Of these 130, about half were determined to be potentially preventable using published criteria (53%) or implicit chart review (48%). Not taking antiretroviral therapy (ART) greatly increased the odds of a preventable readmission (OR 5.9, CI:2.4-14.8). Most of the preventable causes of readmission were attributed to suboptimal care during the index hospitalization. Half of 30-day readmission in HIV patients are potentially preventable. Increased focus on early ART initiation, adherence counseling, management of chronic conditions, and appropriate timing of discharge may help reduce readmissions in this vulnerable population.

  14. Using data linkage to generate 30-day crash-fatality adjustment factors for Taiwan.

    PubMed

    Lai, Ching-Huei; Huang, Wei-Shin; Chang, Kai-Kuo; Jeng, Ming-Chang; Doong, Ji-Liang

    2006-07-01

    Different countries have their own police reporting time standards for counting the number of fatalities in reported crashes. A rapid estimation method (such as adjustment factor) for the comparison is important. The data-linkage technique was used to combine police-reported crash data and vital registration data, in order to generate 30-day fatality adjustment factors for various reporting time standards, which could also shed light on the fatal injury trend over time. The major findings were as follows. Firstly, a conservative 30-day fatality adjustment factor for the first day (or 24 h) would be 1.54 (or 1.35) in an area with a large motorcycle population, like Taiwan. This produced 20-40% higher 30-day fatalities than UK Transport Research Laboratory predicted, and 15-25% higher fatalities than those in Europe/Japan. Secondly, after excluding motorcycle impacts, the Taiwanese factors suggested 8-14% higher fatalities within 30 days than those in Europe/Japan. Third, motorcycle fatalities influenced the overall 30-day fatality trend within 3 days. In the future, both the police under-reporting problem and the motorcycle/overall fatal injury pattern within 3 days after crashing in developing countries like Taiwan merit further investigation. PMID:16430844

  15. Initial weather regimes as predictors of numerical 30-day mean forecast accuracy

    NASA Technical Reports Server (NTRS)

    Colucci, Stephen J.; Baumhefner, David P.

    1992-01-01

    Thirty 30-day mean 500-mb-height anomaly forecasts generated by the NCAR Community Climate Model (CCM) for the year 1978 are examined in order to determine if the forecast accuracy can be estimated with the initial conditions. The initial weather regimes were defined in such a way that the regimes could discriminate between the best and the worst 30-day mean forecasts run from the initial fields in this data set. On the basis of the CCM experiments, it is suggested that the accuracy of numerical 30-day mean forecasts may depend upon the accuracy with which the cyclones and their interactions with the planetary scale are predicted early in the forecast cycle, and that this accuracy may depend upon the initial conditions.

  16. Relationship between obstructive sleep apnea and 30-day mortality among patients with pulmonary embolism

    PubMed Central

    Ghiasi, Farzin; Ahmadpoor, Amin; Amra, Babak

    2015-01-01

    Background: Pulmonary embolism (PE) is the most life-threatening form of venous thrombosis which causes the majority of mortalities in this category. Obstructive sleep apnea (OSA) has been indicated as one of the risk factors for thromboembolism because of hemostatic alterations. The present study was designed to seek for the relationship between OSA and 30-day mortality of patients with PE. Materials and Methods: This prospective cohort study was conducted among 137 consecutive patients referred to hospital with symptoms of PE and preliminary stable hemodynamic. Confirmation of PE was made by multislice computed tomography pulmonary angiography and in the case of contraindication; V/Q lung scan and Doppler sonography were done. A STOP-Bang Questionnaire was used to determine patients with high- and low-risk of OSA. Patients were followed up for 1-month, and their survivals were recorded. Results: This study showed that there was no relationship between OSA and 30-day mortality (P = 0.389). Chronic kidney disease (P = 0.004), hypertension (P = 0.003), main thrombus (P = 0.004), and segmental thrombus (P = 0.022) were associated with 30-day mortality. In the logistic regression analysis, history of chronic kidney disease was diagnosed as a risk factor for 30-day mortality among the PE patients (P = 0.029, odds ratio = 4.93). Conclusion: Results of this study showed 30-day mortality was not affected by OSA directly. In fact, it was affected by complications of OSA such as hypertension and thrombus. Also, positive history of chronic kidney disease increased the risk of 30-day mortality. PMID:26622255

  17. Extent of Surgery Does Not Influence 30-Day Mortality in Surgery for Metastatic Bone Disease

    PubMed Central

    Sørensen, Michala Skovlund; Hindsø, Klaus; Hovgaard, Thea Bechmann; Petersen, Michael Mørk

    2016-01-01

    Abstract Estimating patient survival has hitherto been the main focus when treating metastatic bone disease (MBD) in the appendicular skeleton. This has been done in an attempt to allocate the patient to a surgical procedure that outlives them. No questions have been addressed as to whether the extent of the surgery and thus the surgical trauma reduces survival in this patient group. We wanted to evaluate if perioperative parameters such as blood loss, extent of bone resection, and duration of surgery were risk factors for 30-day mortality in patients having surgery due to MBD in the appendicular skeleton. We retrospectively identified 270 consecutive patients who underwent joint replacement surgery or intercalary spacing for skeletal metastases in the appendicular skeleton from January 1, 2003 to December 31, 2013. We collected intraoperative (duration of surgery, extent of bone resection, and blood loss), demographic (age, gender, American Society of Anesthesiologist score [ASA score], and Karnofsky score), and disease-specific (primary cancer) variables. An association with 30-day mortality was addressed using univariate and multivariable analyses and calculation of odds ratio (OR). All patients were included in the analysis. ASA score 3 + 4 (OR 4.16 [95% confidence interval, CI, 1.80–10.85], P = 0.002) and Karnofsky performance status below 70 (OR 7.34 [95% CI 3.16–19.20], P < 0.001) were associated with increased 30-day mortality in univariate analysis. This did not change in multivariable analysis. No parameters describing the extent of the surgical trauma were found to be associated with 30-day mortality. The 30-day mortality in patients undergoing surgery for MBD is highly dependent on the general health status of the patients as measured by the ASA score and the Karnofsky performance status. The extent of surgery, measured as duration of surgery, blood loss, and degree of bone resection were not associated with 30-day mortality. PMID:27082592

  18. Resource Prospector Propulsion Cold Flow Test

    NASA Technical Reports Server (NTRS)

    Williams, Hunter; Pederson, Kevin; Dervan, Melanie; Holt, Kimberly; Jernigan, Frankie; Trinh, Huu; Flores, Sam

    2014-01-01

    For the past year, NASA Marshall Space Flight Center and Johnson Space Center have been working on a government version of a lunar lander design for the Resource Prospector Mission. A propulsion cold flow test system, representing an early flight design of the propulsion system, has been fabricated. The primary objective of the cold flow test is to simulate the Resource Prospector propulsion system operation through water flow testing and obtain data for anchoring analytical models. This effort will also provide an opportunity to develop a propulsion system mockup to examine hardware integration to a flight structure. This paper will report the work progress of the propulsion cold flow test system development and test preparation. At the time this paper is written, the initial waterhammer testing is underway. The initial assessment of the test data suggests that the results are as expected and have a similar trend with the pretest prediction. The test results will be reported in a future conference.

  19. A 30-day forecast experiment with the GISS model and updated sea surface temperatures

    NASA Technical Reports Server (NTRS)

    Spar, J.; Atlas, R.; Kuo, E.

    1975-01-01

    The GISS model was used to compute two parallel global 30-day forecasts for the month January 1974. In one forecast, climatological January sea surface temperatures were used, while in the other observed sea temperatures were inserted and updated daily. A comparison of the two forecasts indicated no clear-cut beneficial effect of daily updating of sea surface temperatures. Despite the rapid decay of daily predictability, the model produced a 30-day mean forecast for January 1974 that was generally superior to persistence and climatology when evaluated over either the globe or the Northern Hemisphere, but not over smaller regions.

  20. Myelinated fibers of the mouse spinal cord after a 30-day space flight.

    PubMed

    Povysheva, T V; Rezvyakov, P N; Shaimardanova, G F; Nikolskii, E E; Islamov, R R; Chelyshev, Yu A; Grygoryev, A I

    2016-07-01

    Myelinated fibers and myelin-forming cells in the spinal cord at the L3-L5 level were studied in C57BL/6N mice that had spent 30 days in space. Signs of destruction of myelin in different areas of white matter, reduction of the thickness of myelin sheath and axon diameter, decreased number of myelin-forming cells were detected in "flight" mice. The stay of mice in space during 30 days had a negative impact on the structure of myelinated fibers and caused reduced expression of the markers myelin-forming cells. These findings can complement the pathogenetic picture of the development of hypogravity motor syndrome.

  1. Myelinated fibers of the mouse spinal cord after a 30-day space flight.

    PubMed

    Povysheva, T V; Rezvyakov, P N; Shaimardanova, G F; Nikolskii, E E; Islamov, R R; Chelyshev, Yu A; Grygoryev, A I

    2016-07-01

    Myelinated fibers and myelin-forming cells in the spinal cord at the L3-L5 level were studied in C57BL/6N mice that had spent 30 days in space. Signs of destruction of myelin in different areas of white matter, reduction of the thickness of myelin sheath and axon diameter, decreased number of myelin-forming cells were detected in "flight" mice. The stay of mice in space during 30 days had a negative impact on the structure of myelinated fibers and caused reduced expression of the markers myelin-forming cells. These findings can complement the pathogenetic picture of the development of hypogravity motor syndrome. PMID:27595822

  2. Incidence and Predictors of 30-Day Readmission Among Patients Hospitalized for Advanced Liver Disease

    PubMed Central

    BERMAN, KENNETH; TANDRA, SWETA; FORSSELL, KATE; VUPPALANCHI, RAJ; BURTON, JAMES R.; NGUYEN, JAMES; MULLIS, DEVONNE; KWO, PAUL; CHALASANI, NAGA

    2011-01-01

    BACKGROUND & AIMS The rate of readmission to the hospital 30 days after discharge (30-day readmission rate) is used as a quality measure for hospitalized patients, but it has not been studied adequately for patients with advanced liver disease. We investigated the incidence and factors that predict this rate and its relationship with mortality at 90 days. METHODS We analyzed data from patients with advanced liver disease who were hospitalized to an inpatient hepatology service at 2 large academic medical centers in 2008. Patients with elective admission and recipients of liver transplants were not included. During the study period, there were 447 patients and a total of 554 eligible admissions. Multivariate analyses were performed to identify variables associated with 30-day readmission and to examine its relationship with mortality at 90 days. RESULTS The 30-day readmission rate was 20%. After adjusting for multiple covariates, readmission within 30 days was associated independently with model for end-stage liver disease scores at discharge (odds ratio [OR], 1.06; 95% confidence interval [CI], 1.02–1.09; P = .002), the presence of diabetes (OR, 1.78; 95% CI, 1.07–2.95; P = .027), and male sex (OR, 1.73; 95% CI, 1.03–2.89; P = .038). After adjusting for age, sex, and model for end-stage liver disease score at discharge, the 90-day mortality rate was significantly higher among patients who were readmitted to the hospital within 30 days than those who were not (26.8% vs 9.8%; OR, 2.6; 95% CI, 1.36 –5.02; P = .004). CONCLUSIONS Patients with advanced liver disease frequently are readmitted to the hospital within 30 days after discharge; these patients have a higher 90-day mortality rate than those who are not readmitted in 30 days. These data might be used to develop strategies to reduce early readmission of hospitalized patients with cirrhosis. PMID:21092762

  3. 30-Day morbidity after augmentation enterocystoplasty and appendicovesicostomy: a NSQIP pediatric analysis

    PubMed Central

    McNamara, Erin R.; Kurtz, Michael P.; Schaeffer, Anthony J.; Logvinenko, Tanya; Nelson, Caleb P.

    2015-01-01

    Summary Introduction Augmentation enterocystoplasty and appendicovesicostomy are complex pediatric urologic procedures. Although there is literature identifying long-term outcomes in these patients, the reporting of short-term postoperative outcomes has been limited by small numbers of cases and lack of prospective data collection. Here we report 30-day outcomes from the first nationally based, prospectively assembled cohort of pediatric patients undergoing these procedures. Objective To determine 30-day complication, readmission and reoperation after augmentation enterocystoplasty and appendicovesicostomy in a large national sample of pediatric patients, and to explore the association between preoperative and intraoperative characteristics and occurrence of any 30-day event. Study design We queried the 2012 and 2013 American College of Surgeons National Surgical Quality Improvement Program Pediatric database (ACS-NSQIPP) for all patients undergoing augmentation enterocystoplasty and/or appendicovesicostomy. Surgical risk score was classified on a linear scale using a validated pediatric-specific comorbidity score. Intraoperative characteristics and postoperative 30-day events were reported from prospectively collected data. A composite measure of complication, readmission and/or reoperation was used as primary outcome for the multivariate logistic regression. Results There were 461 patients included in the analysis: 245 had appendicovesicostomy, 97 had augmentation enterocystoplasty and 119 had both procedures. There were a total of 110 NSQIP complications seen in 87 patients. The most common complication was urinary tract infection(see Table for 30-day outcomes by patient). The composite measure of any 30-day event was seen in 27.8% of the cohort and this was associated with longer operative time, increased number of procedures done at time of primary surgical procedure and higher surgical risk score. Discussion The ACS-NSQIPP provides a tool to examine short

  4. Impact of the Development of a Regional Collaborative to Reduce 30-Day Heart Failure Readmissions.

    PubMed

    Pollard, Joy; Oliver-McNeil, Sandra; Patel, Shilpa; Mason, Lisa; Baker, Harolyn

    2015-01-01

    Thirty-day heart failure readmissions can be reduced if multiple interventions, such as 7-day postdischarge follow-up, are implemented, but this task is challenging for health systems. Ten hospitals participated in a multisystem collaborative implementing evidence-based strategies. The overall 30-day readmission rate was reduced more in the collaborating hospitals than in the noncollaborating hospitals (from 29.32% to 27.66% vs from 27.66% to 26.03%, P = .008). Regional collaboration between health care systems within a quality improvement project was associated with reduced 30-day readmission.

  5. Effects of leg strength and bicycle ergometry exercise on cardiovascular deconditioning after 30-day head-down bed rest

    NASA Astrophysics Data System (ADS)

    Wu, Bin; Liu, Yusheng; Sun, Hongyi; Zhao, Dongming; Wang, Yue; Wu, Ping; Ni, Chengzhi

    2010-10-01

    The purpose of this study is to determine if the intermittent leg muscular strength exercise and bicycle ergometry exercise could attenuate cardiovascular deconditioning induced by prolonged -6° head-down bed rest (HDBR). Fifteen male subjects were randomly allocated into group A ( n=5, 30 days HDBR without exercise), group B ( n=5, 30 days HDBR with leg muscular strength exercise) and group C ( n=5, 30 days HDBR with bicycle ergometry exercise). The orthostatic tolerance (OT) was determined by +75°/20 min head-up tilt (HUT) test and the submaximal exercise capacity was determined by bicycle ergometry before and after HDBR. The results were as follows: (1) Compared with that before HDBR, OT time decreased dramatically by 57.6% ( p<0.001) after HDBR in group A, while it decreased by 36.4% ( p=0.084) in group B and by 34.7% ( p=0.062) in group C. (2) Compared with that before HDBR, the submaximal exercise time decreased significantly by 17.7% ( p<0.05) and 21.1% ( p<0.05) in groups A and B, respectively, after HDBR. However, it had no change (+1.3%, p>0.77) in group C. (3) compared with that before HDBR, the changes of heart rate (HR) and blood pressure were slightly improved in group B and C, while deteriorated in group A during orthostatic test and exercise test after HDBR. The results indicate that leg muscular strength exercise and bicycle ergometry exercise could partially attenuate the cardiovascular deconditioning induced by 30 d HDBR, and the latter exercise training could fully provide the protection for the loss of exercise capacity.

  6. 77 FR 37706 - Agency Information Collection Activities: 30-Day Notice of Intention To Request Clearance of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF THE INTERIOR National Park Service Agency Information Collection Activities: 30-Day Notice of Intention To Request Clearance of Collection of Information; Opportunity for Public Comment AGENCY: National Park Service,...

  7. 7 CFR 27.58 - Postponed classification; must be within 30 days.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Postponed classification; must be within 30 days. 27.58 Section 27.58 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS...

  8. 77 FR 47702 - 30-Day Notice of Request for Approval: Statutory Authority To Preserve Rail Service

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... this collection in the Federal Register on February 10, 2012, at 77 FR 7236-37 (60-day notice). That... Surface Transportation Board 30-Day Notice of Request for Approval: Statutory Authority To Preserve Rail Service AGENCY: Surface Transportation Board, DOT. ACTION: Notice and request for comments. SUMMARY:...

  9. 78 FR 49280 - 30-Day Notice of Proposed Information Collection: Third-Party Documentation Facsimile Transmittal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-13

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Third-Party Documentation Facsimile..., 2013. A. Overview of Information Collection Title of Information Collection: Third-Party Documentation... of the need for the information and proposed use: The use of the Third-Party Documentation...

  10. 78 FR 7436 - Request for Public Comment: 30-Day Proposed Information Collection: Indian Health Service...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-01

    ... in the Federal Register (77 FR 69865) on November 21, 2012, and allowed 60 days for public comment... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Indian Health Service Request for Public Comment: 30-Day Proposed Information...

  11. 78 FR 79474 - 30-Day Notice of Proposed Information Collection: Father's Day

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-30

    ...HUD has submitted the proposed information collection requirement described below to the Office of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The purpose of this notice is to allow for an additional 30 days of public...

  12. 78 FR 36198 - Request for Public Comment: 30-Day Proposed Information Collection: Indian Health Service Medical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... process has been streamlined and is using information technology to make the application electronically... information technology. Send Requests for Further Information: For the proposed collection, or requests to... HUMAN SERVICES Indian Health Service Request for Public Comment: 30-Day Proposed Information...

  13. Heart failure performance measures: do they have an impact on 30-day readmission rates?

    PubMed

    Mazimba, Sula; Grant, Nakash; Parikh, Analkumar; Mwandia, George; Makola, Diklar; Chilomo, Christine; Redko, Cristina; Hahn, Harvey S

    2013-01-01

    Congestive heart failure (CHF) accounts for more health care costs than any other diagnosis. Readmissions contribute to this expenditure. The authors evaluated the relationship between adherence to performance metrics and 30-day readmissions. This was a retrospective study of 6063 patients with CHF between 2001 and 2008. Data were collected for 30-day readmissions and compliance with CHF performance measures at discharge. Rates of readmission for CHF increased from 16.8% in 2002 to 24.8% in 2008. Adherence to performance measures increased concurrently from 95.8% to 99.9%. Except for left ventricular function (LVF) assessment, the 30-day readmission rate was not associated with adherence to performance measures. Readmitted patients had twice the odds of not having their LVF assessed (odds ratio = 2.0; P < .00005; 95% confidence interval = 1.45-2.63). CHF performance measures, except for the LVF assessment, have little relationship to 30-day readmissions. Further studies are needed to identify performance measures that correlate with quality of care. PMID:23110998

  14. 76 FR 10035 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... HUMAN SERVICES Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov AGENCY..., OMB number, to Ed.Calimag@hhs.gov , or call the Reports Clearance Office on (202) 205- 1193. Send... notice directly to the Grants.gov OMB Desk Officer; faxed to OMB at 202-395-6974. Proposed Project:...

  15. 76 FR 10036 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... HUMAN SERVICES Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov AGENCY..., OMB number, to Ed.Calimag@hhs.gov , or call the Reports Clearance Office on (202) 205- 1193. Send... notice directly to the Grants.gov OMB Desk Officer; faxed to OMB at 202-395-6974. Proposed Project:...

  16. 76 FR 10034 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... HUMAN SERVICES Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov AGENCY..., OMB number, to Ed.Calimag@hhs.gov , or call the Reports Clearance Office on (202) 205- 1193. Send... notice directly to the Grants.gov OMB Desk Officer; faxed to OMB at 202-395-6974. Proposed Project:...

  17. 76 FR 10364 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... HUMAN SERVICES Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov AGENCY..., OMB number, to Ed.Calimag@hhs.gov , or call the Reports Clearance Office on (202) 205- 1193. Send... notice directly to the Grants.gov OMB Desk Officer; faxed to OMB at 202-395-6974. Proposed Project:...

  18. 76 FR 10033 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... HUMAN SERVICES Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov AGENCY..., OMB number, to Ed.Calimag@hhs.gov , or call the Reports Clearance Office on (202) 690- 7569. Send... notice directly to the Grants.gov OMB Desk Officer; faxed to OMB at 202-395-6974. Proposed Project:...

  19. 78 FR 48178 - Submission for OMB Review; 30-day Comment Request: Autism Spectrum Disorder Research Portfolio...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-07

    ... HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-day Comment Request: Autism... any data that is collected on autism projects that are funded. This comment was considered, but it did..., contact: The Office of Autism Research Coordination, NIMH, NIH, Neuroscience Center, 6001 Executive...

  20. 78 FR 1916 - 30-Day Notice of Proposed Information Collection: Smart Traveler Enrollment Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ...The Department of State has submitted the information collection described below to the Office of Management and Budget (OMB) for approval. In accordance with the Paperwork Reduction Act of 1995 we are requesting comments on this collection from all interested individuals and organizations. The purpose of this Notice is to allow 30 days for public...

  1. 78 FR 66042 - 30-Day Notice of Proposed Information Collection: Section 3 Business Registry Pilot Program...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Section 3 Business Registry Pilot..., Reports Management Officer, QDAM, Department of Housing and Urban Development, 451 7th Street...

  2. 78 FR 69103 - 30-Day Notice of Proposed Information Collection: Quality Control for Rental Assistance Subsidy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ...HUD has submitted the proposed information collection requirement described below to the Office of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The purpose of this notice is to allow for an additional 30 days of public...

  3. 78 FR 19496 - Submission for OMB Review; 30-day Comment Request; The National Cancer Institute (NCI...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-01

    ... of eHealth/ mHealth tobacco cessation intervention programs. SmokefreeTXT has been developed (and is... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-day Comment Request;...

  4. 78 FR 36560 - 30-Day Notice of Proposed Information Collection: FHA Lender Approval, Annual Renewal, Periodic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: FHA Lender Approval, Annual Renewal...: Colette Pollard, Reports Management Officer, QDAM, Department of Housing and Urban Development, 451 7th... Title of Information Collection: FHA Lender Approval, Annual Renewal, Periodic Updates and...

  5. 78 FR 52964 - 30-Day Notice of Proposed Information Collection: Section 8 Management Assessment Program (SEMAP...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Section 8 Management Assessment... of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The... Officer, Office of Management and Budget, New Executive Office Building, Washington, DC 20503; fax:...

  6. 78 FR 70956 - 30-Day Notice of Proposed Information Collection: Assessment of Native American, Alaska Native...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-27

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Assessment of Native American... Title of Information Collection: Assessment of Native American, Alaska Native and Native Hawaiian... American and Alaskan Native populations, most notably through the Indian Housing Block Grant. The level...

  7. 76 FR 28987 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-19

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency Information Collection Request; 30-Day Public Comment Request AGENCY: Office of the Secretary, HHS. In compliance with the requirement of section 3506(c)(2)(A) of the Paperwork Reduction Act of 1995, the Office of the Secretary...

  8. 78 FR 78369 - Submission for OMB Review; 30-Day Comment Request: Early Career Reviewer Program Online...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-Day Comment Request: Early.... Currently, the application process involves repeated email interactions with potential applicants and...

  9. 75 FR 48970 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the Secretary Agency Information Collection Request; 30-Day Public Comment... Human Services, is publishing the following summary of a proposed collection for public...

  10. 75 FR 48969 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency Information Collection Request. 30 Day Public Comment Request AGENCY: Office of... Reduction Act of 1995, the Office of the Secretary (OS), Department of Health and Human Services,...

  11. 30-Day Mortality in Acute Pulmonary Embolism: Prognostic Value of Clinical Scores and Anamnestic Features

    PubMed Central

    Bach, Andreas Gunter; Taute, Bettina-Maria; Baasai, Nansalmaa; Wienke, Andreas; Meyer, Hans Jonas; Schramm, Dominik; Surov, Alexey

    2016-01-01

    Purpose Identification of high-risk patients with pulmonary embolism is vital. The aim of the present study was to examine clinical scores, their single items, and anamnestic features in their ability to predict 30-day mortality. Materials and Methods A retrospective, single-center study from 06/2005 to 01/2010 was performed. Inclusion criteria were presence of pulmonary embolism, availability of patient records and 30-day follow-up. The following clinical scores were calculated: Acute Physiology and Chronic Health Evaluation II, original and simplified pulmonary embolism severity index, Glasgow Coma Scale, and euroSCORE II. Results In the study group of 365 patients 39 patients (10.7%) died within 30 days due to pulmonary embolism. From all examined scores and parameters the best predictor of 30-day mortality were the Glasgow Coma scale (≤ 10) and parameters of the circulatory system including presence of mechanical ventilation, arterial pH (< 7.335), and systolic blood pressure (< 99 mm Hg). Conclusions Easy to ascertain circulatory parameters have the same or higher prognostic value than the clinical scores that were applied in this study. From all clinical scores studied the Glasgow Coma Scale was the most time- and cost-efficient one. PMID:26866472

  12. 78 FR 36564 - 30-Day Notice of Proposed Information Collection: Multifamily Default Status Report

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Multifamily Default Status Report..., Department of Housing and Urban Development, 451 7th Street SW., Washington, DC 20410; email Colette Pollard... Report. OMB Approval Number: 2502-0041. Type of Request: Extension of a currently approved...

  13. 78 FR 39305 - 30-Day Notice of Proposed Information Collection: OSHC Progress Report Template

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: OSHC Progress Report Template AGENCY... Urban Development, 451 7th Street SW., Washington, DC 20410; email Colette Pollard at Colette.Pollard... Information Collection Title of Information Collection: OSHC Progress Report Template. OMB Approval...

  14. 78 FR 38070 - 30-Day Notice of Proposed Information Collection: Affirmative Fair Housing Marketing (AFHM) Plan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-25

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Affirmative Fair Housing Marketing... Marketing (AFHM) Plan. OMB Approval Number: 2529-0013. Type of Request: Extension of a currently approved collection. Form Number: HUD-935.2A Affirmative Fair Housing Marketing (AFHM) Plan (Multifamily),...

  15. [Separate birth 30 days after a premature delivery in a twin pregnancy. A case report].

    PubMed

    Kisoka, R

    1994-01-01

    The author reports an exceptional observation concerning a delayed delivery of a second twin born at 34 weeks' gestation. The first infant was born 30 days before. The "fetal retention" of the second twin seems to improve its vital prognostic, 12 months later, the infant was in full growth and showing a good health. PMID:7995920

  16. 76 FR 40913 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... respondent (in hours) hours Survey Human Resource Manager 3,000 1 30/60 1,500 Focus Group Protocol Employees in All 48 1 1.5 72 Occupations Key Informant Interview Script...... Human Resource Manager 20 1 45/60... HUMAN SERVICES Agency Information Collection Request; 30-Day Public Comment Request AGENCY: Office...

  17. Utilization of trained volunteers decreases 30-day readmissions for heart failure.

    PubMed

    Sales, Virna L; Ashraf, Muhammad Salman; Lella, Leela K; Huang, Jiaxin; Bhumireddy, Geetha; Lefkowitz, Lance; Feinstein, Mimi; Kamal, Mikail; Caesar, Raqib; Cusick, Elizabeth; Norenberg, Jane; Lee, Jiwon; Brener, Sorin; Sacchi, Terrence J; Heitner, John F

    2014-05-01

    Background: This study evaluated the effectiveness of using trained volunteer staff in reducing 30-day readmissions of congestive heart failure (CHF) patients.Methods: From June 2010 to December 2010, 137 patients (mean age 73 years) hospitalized for CHF were randomly assigned to either: an interventional arm (arm A) receiving dietary and pharmacologic education by a trained volunteer, follow-up telephone calls within 48 hours, and a month of weekly calls; ora control arm (arm B) receiving standard care. Primary outcomes were 30-day readmission rates for CHF and worsening New York Heart Association (NYHA) functional classification; composite and all-cause mortality were secondary outcomes.Results: Arm A patients had decreased 30-day readmissions (7% vs 19%; P ! .05) with a relative risk reduction (RRR) of 63% and an absolute risk reduction (ARR) of 12%. The composite outcome of 30-day readmission, worsening NYHA functional class, and death was decreased in the arm A (24% vs 49%;P ! .05; RRR 51%, ARR 25%). Standard-care treatment and hypertension, age $65 years and hypertension,and cigarette smoking were predictors of increased risk for readmissions, worsening NYHA functional class, and all-cause mortality, respectively, in the multivariable analysis.Conclusions: Utilizing trained volunteer staff to improve patient education and engagement might be an efficient and low-cost intervention to reduce CHF readmissions.

  18. 78 FR 79475 - 30-Day Notice of Proposed Information Collection: The Impact of Housing and Services...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-30

    ...HUD has submitted the proposed information collection requirement described below to the Office of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The purpose of this notice is to allow for an additional 30 days of public...

  19. 78 FR 56908 - 30-Day Notice of Proposed Information Collection: Training Evaluation Form

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-16

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Training Evaluation Form AGENCY... Information Collection Title of Information Collection: Training Evaluation Form. OMB Approval Number: 2577... Evaluation Form is currently being used and will be used are: On-site Core Curriculum training in...

  20. 78 FR 36563 - 30-Day Notice of Proposed Information Collection: Single Family Premium Collection Subsystem...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Single Family Premium Collection..., 2013. A. Overview of Information Collection Title of Information Collection: Single Family Premium... use: The Single Family Premium Collection Subsystem-Upfront (SFPCS-U) allows the lenders to remit...

  1. 78 FR 75366 - 30-Day Notice of Proposed Information Collection: Public Housing Energy Audits and Utility...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-11

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Public Housing Energy Audits and... Audits and Utility Allowances. OMB Approval Number: 2577-062. Type of Request: Reinstatement, with change... information and proposed use: 24 CFR 965.301, Subpart C, Energy Audit and Energy Conservation...

  2. 77 FR 39318 - 30-Day Notice of Proposed Information Collection: DS-5513, Supplemental Questionnaire To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-02

    ..., Office of Project Management and Operational Support, Program Coordination (CA/PPT/PMO/PC) Form Number... information collection request to the Office of Management and Budget (OMB) for approval in accordance with... to the Office of Management and Budget (OMB) for up to 30 days from July 2, 2012. ADDRESSES:...

  3. 77 FR 29348 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-17

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency Information Collection Request; 30-Day Public Comment Request AGENCY: Office of the Secretary, HHS. In compliance with the requirement of section 3506(c)(2)(A) of the Paperwork Reduction Act of 1995, the Office of the Secretary...

  4. 76 FR 32008 - 30-Day Notice of Proposed Information Collections: RPPR Public Diplomacy Surveys

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... forms of social media and similar collaborative technologies to interact on Public Diplomacy themes in... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day Notice of Proposed Information Collections: RPPR Public Diplomacy Surveys ACTION: Notice of request...

  5. 77 FR 13128 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... social media PSA. This study will collect information on awareness of the ``Make the Call--Don't Miss a... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Agency Information Collection Request; 30-Day Public Comment Request AGENCY: Office...

  6. 78 FR 52009 - 30-Day Notice of Proposed Information Collection: Utility Allowance Adjustments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-21

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Utility Allowance Adjustments AGENCY... Information Collection Title of Information Collection: Utility Allowance Adjustments. OMB Approval Number... advise the Secretary of the need for and request approval of a new utility allowance for...

  7. 78 FR 36565 - 30-Day Notice of Proposed Information Collection: Standardized Form for Collecting Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-18

    ...HUD has submitted the proposed information collection requirement described below to the Office of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The purpose of this notice is to allow for an additional 30 days of public...

  8. 76 FR 10037 - Agency Information Collection Request. 30-Day Public Comment Request, Grants.gov

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... written comments and recommendations for the proposed information collections within 30 days of this... ``General Instructions'' section, the following sentence is added as the last sentence: ``In ALL cases total... B Budget Categories'' section, the last sentence is revised as follows: ``For each program,...

  9. READMIT: a clinical risk index to predict 30-day readmission after discharge from acute psychiatric units.

    PubMed

    Vigod, Simone N; Kurdyak, Paul A; Seitz, Dallas; Herrmann, Nathan; Fung, Kinwah; Lin, Elizabeth; Perlman, Christopher; Taylor, Valerie H; Rochon, Paula A; Gruneir, Andrea

    2015-02-01

    Our aim was to create a clinically useful risk index, administered prior to discharge, for determining the probability of psychiatric readmission within 30 days of hospital discharge for general psychiatric inpatients. We used population-level sociodemographic and health administrative data to develop a predictive model for 30-day readmission among adults discharged from an acute psychiatric unit in Ontario, Canada (2008-2011), and converted the final model into a risk index system. We derived the predictive model in one-half of the sample (n = 32,749) and validated it in the other half of the sample (n = 32,750). Variables independently associated with 30-day readmission (forming the mnemonic READMIT) were: (R) Repeat admissions; (E) Emergent admissions (i.e. harm to self/others); (D) Diagnoses (psychosis, bipolar and/or personality disorder), and unplanned Discharge; (M) Medical comorbidity; (I) prior service use Intensity; and (T) Time in hospital. Each 1-point increase in READMIT score (range 0-41) increased the odds of 30-day readmission by 11% (odds ratio 1.11, 95% CI 1.10-1.12). The index had moderate discriminative capacity in both derivation (C-statistic = 0.631) and validation (C-statistic = 0.630) datasets. Determining risk of psychiatric readmission for individual patients is a critical step in efforts to address the potentially avoidable high rate of this negative outcome. The READMIT index provides a framework for identifying patients at high risk of 30-day readmission prior to discharge, and for the development, evaluation and delivery of interventions that can assist with optimizing the transition to community care for patients following psychiatric discharge.

  10. Risk Factors for 30-Day Hospital Readmission among General Surgery Patients

    PubMed Central

    Kassin, Michael T; Owen, Rachel M; Perez, Sebastian; Leeds, Ira; Cox, James C; Schnier, Kurt; Sadiraj, Vjollca; Sweeney, John F

    2012-01-01

    Background Hospital readmission within 30-days of an index hospitalization is receiving increased scrutiny as a marker of poor quality patient care. This study identifies factors associated with 30-day readmission following General Surgery procedures. Study Design Using standard National Surgical Quality Improvement Project (NSQIP) protocol, preoperative, intraoperative, and postoperative outcomes were collected on patients undergoing inpatient General Surgery procedures at a single academic center between 2009 and 2011. Data were merged with our institutional clinical data warehouse to identify unplanned 30-day readmissions. Demographics, comorbidities, type of procedure, postoperative complications, and ICD-9 coding data were reviewed for patients who were readmitted. Univariate and multivariate analysis was utilized to identify risk factors associated with 30-day readmission. Results 1442 General Surgery patients were reviewed. 163 (11.3%) were readmitted within 30 days of discharge. The most common reasons for readmission were gastrointestinal complaint/complication (27.6%), surgical infection (22.1%), and failure to thrive/malnutrition (10.4%). Comorbidities associated with risk of readmission included disseminated cancer, dyspnea, and preoperative open wound (p<0.05 for all variables). Surgical procedures associated with higher rates of readmission included pancreatectomy, colectomy, and liver resection. Postoperative occurrences leading to increased risk of readmission were blood transfusion, postoperative pulmonary complication, wound complication, sepsis/shock, urinary tract infection, and vascular complications. Multivariable analysis demonstrates that the most significant independent risk factor for readmission is the occurrence of any postoperative complication (OR 4.20, 95% CI 2.89–6.13). Conclusions Risk factors for readmission after General Surgery procedures are multi-factorial; however, postoperative complications appear to drive readmissions in

  11. Cirrhosis is Associated with an Increased 30-Day Mortality After Venous Thromboembolism

    PubMed Central

    Søgaard, Kirstine Kobberøe; Horváth-Puhó, Erzsébet; Montomoli, Jonathan; Vilstrup, Hendrik; Sørensen, Henrik Toft

    2015-01-01

    Objectives: Patients with cirrhosis are at increased risk of venous thromboembolism (VTE), but the impact of cirrhosis on the clinical course following VTE is unclear. In a nationwide cohort study, we examined 30-day mortality among patients with cirrhosis and VTE. Methods: We used Danish population-based health-care databases (1994–2011) to identify patients with incident VTE, i.e., deep venous thrombosis (DVT), pulmonary embolism (PE), and portal vein thrombosis (PVT). Among these, we identified 745 patients with cirrhosis and 3647 patients without cirrhosis (matched on gender, year of birth, calendar year of VTE diagnosis and VTE type). We assessed the 30-day mortality risk among VTE patients with and without cirrhosis, and the mortality rate ratios (MRRs), using an adjusted Cox model with 95% confidence interval. We obtained information on immediate cause of death for patients who died within 30 days after VTE. Results: The 30-day mortality risk for DVT was 7% for patients with cirrhosis and 3% for patients without cirrhosis. Corresponding PE-related mortality risks were 35% and 16%, and PVT-related mortality risks were 19% and 15%, respectively. The adjusted 30-day MRRs were 2.17 (1.24–3.79) for DVT, 1.83 (1.30–2.56) for PE, and 1.30 (0.80–2.13) for PVT. Though overall mortality was higher in patients with cirrhosis than patients without cirrhosis, the proportions of deaths due to PE were similar among patients (25% and 24%, respectively). Conclusions: Cirrhosis is a predictor for increased short-term mortality following VTE, with PE as the most frequent cause of death. PMID:26133110

  12. LADEE Propulsion System Cold Flow Test

    NASA Technical Reports Server (NTRS)

    Williams, Jonathan Hunter; Chapman, Jack M.; Trinh, Hau, P.; Bell, James H.

    2013-01-01

    Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA mission that will orbit the Moon. Its main objective is to characterize the atmosphere and lunar dust environment. The spacecraft development is being led by NASA Ames Research Center and scheduled for launch in 2013. The LADEE spacecraft will be operated with a bi-propellant hypergolic propulsion system using MMH and NTO as the fuel and oxidizer, respectively. The propulsion system utilizes flight-proven hardware on major components. The propulsion layout is composed of one 100-lbf main thruster and four 5-lbf RCS thrusters. The propellants are stored in four tanks (two parallel-connected tanks per propellant component). The propellants will be pressurized by regulated helium. A simulated propulsion system has been built for conducting cold flow test series to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes, such as system priming, waterhammer, and crucial mission duty cycles. Propellant drainage differential between propellant tanks will also be assessed. Since the oxidizer feed line system has a higher flow demand than the fuel system does, the cold flow test focuses on the oxidizer system. The objective of the cold flow test is to simulate the LADEE propulsion fluid flow operation through water cold flow test and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. The test activities, including the simulated propulsion test article, cold flow test, and analytical modeling, are being performed at NASA Marshall Space Flight Center. At the time of the abstract submission, the test article checkout is being performed. The test series will be completed by November, 2012

  13. Work capacity during 30 days of bed rest with isotonic and isokinetic exercise training

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Trowbridge, T. S.; Wade, C. E.

    1989-01-01

    Results are presented from a study to determine whether or not short-term variable intensity isotonic and intermittent high-intensity isokinetic short-duration leg exercise is effective for the maintenance of peak O2 (VO2) uptake and muscular strength and endurance, respectively, during 30 days of -6 deg head-down bed rest deconditioning. The results show no significant changes in leg peak torque, leg mean total work, arm total peak torque, or arm mean total work for members of the isotonic, isokinetic, and controls groups. Changes are observed, however, in peak VO2 levels. The results suggest that near-peak variabile intensity, isotonic leg excercise maintains peak VO2 during 30 days of bed rest, while peak intermittent, isokinetic leg excercise protocol does not.

  14. Influence of psychiatric comorbidity on 30-day readmissions for heart failure, myocardial infarction, and pneumonia

    PubMed Central

    Ahmedani, Brian K.; Solberg, Leif I.; Copeland, Laurel; Fang, Ying; Stewart, Christine; Hu, Jianhui; Nerenz, David R.; Williams, L. Keoki; Cassidy-Bushrow, Andrea E.; Waxmonsky, Jeanette; Lu, Christine Y.; Waitzfelder, Beth E.; Owen-Smith, Ashli A.; Coleman, Karen J.; Lynch, Frances L.; Ahmed, Ameena T.; Beck, Arne L.; Rossom, Rebecca C.; Simon, Gregory E.

    2014-01-01

    Objective The Centers for Medicare and Medicaid Services (CMS) implemented a policy in 2012 that penalizes hospitals for ‘excessive’ all-cause hospital readmissions within 30 days after discharge for heart failure (HF), acute myocardial infarction (AMI), and pneumonia. The aim of this study is to investigate the influence of psychiatric comorbidities on 30-day all-cause readmissions for heart failure, acute myocardial infarction, and pneumonia. Methods Longitudinal study from 2009-2011 within 11 Mental Health Research Network (MHRN) affiliated health systems. Data were derived from the HMO Research Network Virtual Data Warehouse. Participants were individuals admitted to the hospital for HF, AMI, and pneumonia. All index inpatient hospitalizations for HF, AMI and pneumonia were captured (n=160,169 patient index admissions). Psychiatric diagnoses were measured for the year prior to admission. All-cause readmissions within 30 days of discharge were the outcome variable. Results Approximately 18% of all individuals with these conditions were readmitted within 30-days. The rate was 5% greater for individuals with a past-year psychiatric comorbidity (21.7%) than for those without (16.5%; p<.001). Depression, anxiety, and dementia were associated with more readmissions for those with index hospitalizations for all three conditions independently and combined (p<.05). Substance use and bipolar disorders were linked with higher readmissions for those with initial HF and pneumonia hospitalizations (p<.05). Readmission rates declined overall from 2009-2011. Conclusions Individuals with HF, AMI, and pneumonia experience high rates of readmission, but psychiatric comorbidities appear to increase that risk. Future readmission interventions should consider adding mental health components. PMID:25642610

  15. A quality improvement plan to reduce 30-day readmissions of heart failure patients.

    PubMed

    Simpson, Monica

    2014-01-01

    An evidence-based quality initiative to decrease heart failure 30-day readmissions was implemented at a hospital in Florida. Heart failure education and postdischarge telephone contact were provided to patients determined to be at high risk of readmission using risk stratification tools. The rate during the project decreased 13% as compared to the same time period in the previous year and 8.5% from the 2012 year to date rate.

  16. Incidence, Causes and Predictors of 30-Day Readmission After Shoulder Arthroplasty

    PubMed Central

    Westermann, Robert W; Anthony, Chris A.; Duchman, Kyle R.; Pugely, Andrew J.; Gao, Yubo; Hettrich, Carolyn M.

    2016-01-01

    Background The Center for Medicare and Medicaid Service has identified several quality metrics, including unplanned readmission within 30 days of surgery, to assess and compare surgeons and hospitals. The purpose of this study was to identify the incidence, causes and risk factors for unplanned 30-day readmission after total shoulder arthroplasty. Methods We identified patients undergoing primary elective shoulder arthroplasty performed at American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) participating hospitals in 2013. Cases were stratified by readmission status. Univariate and multivariate analyses were employed to assess patient demographics, comorbidities and operative variables predicting unplanned readmission. Results 2779 patients undergoing shoulder arthroplasty were identified, with 74 (2.66%) requiring unplanned readmissions within 30 days of surgery. The most common surgical causes for unplanned readmission were surgical site infections (18.6%), dislocations (16.3%) and venous thromboembolism (14.0%). Medical causes for readmission were responsible for 51% of unplanned readmissions. Multivariate analysis identified patient age >75 (OR 2.62, 95% CI: 1.27 - 5.41), and ASA class of 3 (OR 1.79, 95% CI: 1.01 - 3.18) or 4 (OR 3.63, 95% CI: 1.31 - 10.08) as independent risk factors for unplanned readmission. Predictive modeling estimated that patients with ASA class of 4 and age >75 are 17.4 times more likely (95% CI 1.77-171.09) to be readmitted within 30 days of shoulder arthroplasty. Conclusion Unplanned readmission after shoulder arthroplasty is infrequent and medical complications account for more than 50% of occurrences. The risk of readmission exponentially increases when age and preoperative comorbidity burden are increased. PMID:27528839

  17. Women are less likely to be admitted to substance abuse treatment within 30 days of assessment.

    PubMed

    Arfken, Cynthia L; Borisova, Natalie; Klein, Chris; di Menza, Salvatore; Schuster, Charles R

    2002-01-01

    The information gathered in a centralized intake unit (CIU) allows payers and administrators to examine if there are access issues for their population. For this study, the authors examined whether there were gender differences in the rate at which people are admitted to treatment within 30 days of assessment. Of the 5,004 individuals seeking publicly-funded substance abuse treatment in Detroit for the years 1996-97, 50.3% of those assessed at the CIU actually entered treatment. Women (31% of the people assessed) had a lower rate of admission (45% for women versus 53% for men) a difference that was maintained even after controlling for known risk factors. Women who were given priority for admission (i.e., those who were pregnant, had children, or injected drugs) had a higher rate of admission than other women (73% versus 39%), but only 17% of the women presenting were included in the priority groups. Men who were injecting drugs (a priority group) also had a higher rate of admission than other men (83% versus 49%). In multivariate analysis controlling for priority groups and known risk factors, women were still less likely to be admitted to treatment within 30 days of admission than men. Establishing priorities improves the rate of admission within 30 days of assessment for those groups, but more needs to be done to improve the admission rate for women. These results demonstrate that a CIU allows administrators to monitor for access issues.

  18. The 10-30-day intraseasonal variation of the East Asian winter monsoon: The temperature mode

    NASA Astrophysics Data System (ADS)

    Yao, Suxiang; Sun, Qingfei; Huang, Qian; Chu, Peng

    2016-09-01

    East Asia is known for its monsoon characteristics, but little research has been performed on the intraseasonal time scale of the East Asian winter monsoon (EAWM). In this paper, the extended reanalysis (ERA)-Interim sub-daily data are used to study the surface air temperature intraseasonal oscillation (ISO) of the EAWM. The results show that the air temperature (2-m level) of the EAWM has a dominant period of 10-30 days. Lake Baikal and south China are the centers of the air temperature ISO. An anomalous low frequency (10-30-day filtered) anticyclone corresponds to the intraseasonal cold air. The 10-30-day filtered cold air spreads from Novaya Zemlya to Lake Baikal and even to South China. The ISO of the Arctic Oscillation (AO) index influences the temperature of the EAWM by stimulating Rossby waves in middle latitude, causing meridional circulation, and eventually leads to the temperature ISO of the EAWM. RegCM4 has good performance for the simulation of the air temperature ISO. The simulated results indicate that the plateau is responsible for the southward propagation of the intraseasonal anticyclone. The anticyclone could not reach South China when there was no plateau in western China and its upper reaches.

  19. Comparison of robotic and laparoscopic colorectal resections with respect to 30-day perioperative morbidity

    PubMed Central

    Feinberg, Adina E.; Elnahas, Ahmad; Bashir, Shaheena; Cleghorn, Michelle C.; Quereshy, Fayez A.

    2016-01-01

    Background Robotic surgery has emerged as a minimally invasive alternative to traditional laparoscopy. Robotic surgery addresses many of the technical and ergonomic limitations of laparoscopic surgery, but the literature regarding clinical outcomes in colorectal surgery is limited. We sought to compare robotic and laparoscopic colorectal resections with respect to 30-day perioperative outcomes. Methods The American College of Surgeons National Surgical Quality Improvement Program database was used to identify all patients who underwent robotic or laparoscopic colorectal surgery in 2013. We performed a logistic regression analysis to compare intraoperative variables and 30-day outcomes. Results There were 8392 patients who underwent laparoscopic colorectal surgery and 472 patients who underwent robotic colorectal surgery. The robotic cohort had a lower incidence of unplanned intraoperative conversion (9.5% v. 13.7%, p = 0.008). There were no significant differences between robotic and laparoscopic surgery with respect to other intraoperative and postoperative outcomes, such as operative duration, length of stay, postoperative ileus, anastomotic leak, venous thromboembolism, wound infection, cardiac complications and pulmonary complications. On multivariable analysis, robotic surgery was protective for unplanned conversion, while male sex, malignancy, Crohn disease and diverticular disease were all associated with open conversion. Conclusion Robotic colorectal surgery has comparable 30-day perioperative morbidity to laparoscopic surgery and may decrease the rate of intraoperative conversion in select patients. PMID:27240135

  20. Quantifiable Lateral Flow Assay Test Strips

    NASA Technical Reports Server (NTRS)

    2003-01-01

    As easy to read as a home pregnancy test, three Quantifiable Lateral Flow Assay (QLFA) strips used to test water for E. coli show different results. The brightly glowing control line on the far right of each strip indicates that all three tests ran successfully. But the glowing test line on the middle left and bottom strips reveal their samples were contaminated with E. coli bacteria at two different concentrations. The color intensity correlates with concentration of contamination.

  1. Risk Factors and Indications for 30-Day Readmission After Primary Surgery for Epithelial Ovarian Cancer

    PubMed Central

    AlHilli, Mariam; Langstraat, Carrie; Tran, Christine; Martin, Janice; Weaver, Amy; McGree, Michaela; Mariani, Andrea; Cliby, William; Bakkum-Gamez, Jamie

    2015-01-01

    Background To identify patients at risk for postoperative morbidities, we evaluated indications and factors associated with 30-day readmission after epithelial ovarian cancer surgery. Methods Patients undergoing primary surgery for epithelial ovarian cancer between January 2, 2003, and December 29, 2008, were evaluated. Univariable and multivariable logistic regression models were fit to identify factors associated with 30-day readmission. A parsimonious multivariable model was identified using backward and stepwise variable selection. Results In total, 324 (60.2%) patients were stage III and 91 (16.9%) were stage IV. Of all 538 eligible patients, 104 (19.3%) were readmitted within 30 days. Cytoreduction to no residual disease was achieved in 300 (55.8%) patients, and 167 (31.0%) had measurable disease (≤1 cm residual disease). The most common indications for readmission were surgical site infection (SSI; 21.2%), pleural effusion/ascites management (14.4%), and thromboembolic events (12.5%). Multivariate analysis identified American Society of Anesthesiologists score of 3 or higher (odds ratio, 1.85; 95% confidence interval, 1.18–2.89; P = 0.007), ascites [1.76 (1.11–2.81); P = 0.02], and postoperative complications during initial admission [grade 3–5 vs none, 2.47 (1.19–5.16); grade 1 vs none, 2.19 (0.98–4.85); grade 2 vs none, 1.28 (0.74–2.21); P = 0.048] to be independently associated with 30-day readmission (c-index = 0.625). Chronic obstructive pulmonary disease was the sole predictor of readmission for SSI (odds ratio, 3.92; 95% confidence interval, 1.07–4.33; P = 0.04). Conclusions Clinically significant risk factors for 30-day readmission include American Society of Anesthesiologists score of 3 or higher, ascites and postoperative complications at initial admission. The SSI and pleural effusions/ascites are common indications for readmission. Systems can be developed to predict patients needing outpatient management, improve care, and reduce

  2. Increased 30-Day Emergency Department Revisits Among Homeless Patients with Mental Health Conditions

    PubMed Central

    Lam, Chun Nok; Arora, Sanjay; Menchine, Michael

    2016-01-01

    Introduction Patients with mental health conditions frequently use emergency medical services. Many suffer from substance use and homelessness. If they use the emergency department (ED) as their primary source of care, potentially preventable frequent ED revisits and hospital readmissions can worsen an already crowded healthcare system. However, the magnitude to which homelessness affects health service utilization among patients with mental health conditions remains unclear in the medical community. This study assessed the impact of homelessness on 30-day ED revisits and hospital readmissions among patients presenting with mental health conditions in an urban, safety-net hospital. Methods We conducted a secondary analysis of administrative data on all adult ED visits in 2012 in an urban safety-net hospital. Patient demographics, mental health status, homelessness, insurance coverage, level of acuity, and ED disposition per ED visit were analyzed using multilevel modeling to control for multiple visits nested within patients. We performed multivariate logistic regressions to evaluate if homelessness moderated the likelihood of mental health patients’ 30-day ED revisits and hospital readmissions. Results Study included 139,414 adult ED visits from 92,307 unique patients (43.5±15.1 years, 51.3% male, 68.2% Hispanic/Latino). Nearly 8% of patients presented with mental health conditions, while 4.6% were homeless at any time during the study period. Among patients with mental health conditions, being homeless contributed to an additional 28.0% increase in likelihood (4.28 to 5.48 odds) of 30-day ED revisits and 38.2% increase in likelihood (2.04 to 2.82 odds) of hospital readmission, compared to non-homeless, non-mental health (NHNM) patients as the base category. Adjusted predicted probabilities showed that homeless patients presenting with mental health conditions have a 31.1% chance of returning to the ED within 30-day post discharge and a 3.7% chance of hospital

  3. Risk factors for 30-day readmission following hypoglycemia-related emergency room and inpatient admissions

    PubMed Central

    Emons, M F; Bae, J P; Hoogwerf, B J; Kindermann, S L; Taylor, R J; Nathanson, B H

    2016-01-01

    Objective Hypoglycemia is a serious complication of diabetes treatment. This retrospective observational study characterized hypoglycemia-related hospital emergency room (ER) and inpatient (in-pt) admissions and identified risk factors for 30-day all-cause and hypoglycemia-related readmission. Research design and methods 4476 hypoglycemia-related ER and in-pt encounters with discharge dates from 1/1/2009 to 3/31/2014 were identified in a large, multicenter electronic health record database. Outcomes were 30-day all-cause ER/hospital readmission and hypoglycemia-related readmission. Multivariable logistic regression methods identified risk factors for both outcomes. Results 1095 (24.5%) encounters had ER/hospital all-cause readmission within 30 days and 158 (14.4%) of these were hypoglycemia-related. Predictors of all-cause 30-day readmission included recent exposure to a hospital/nursing home (NH)/skilled nursing facility (SNF; OR 1.985, p<0.001); age 25–34 and 35–44 (OR 2.334 and 1.996, respectively, compared with age 65–74, both p<0.001); and African-American (AA) race versus all other race categories (OR 1.427, p=0.011). Other factors positively associated with readmission include chronic obstructive pulmonary disease, cerebrovascular disease, cardiac dysrhythmias, congestive heart disease, hypertension, and mood disorders. Predictors of readmissions attributable to hypoglycemia included recent exposure to a hospital/NH/SNF (OR 2.299, p<0.001), AA race (OR 1.722, p=0.002), age 35–44 (OR 3.484, compared with age 65–74, p<0.001), hypertension (OR 1.891, p=0.019), and delirium/dementia and other cognitive disorders (OR 1.794, p=0.038). Obesity was protective against 30-day hypoglycemia-related readmission (OR 0.505, p=0.017). Conclusions Factors associated with 30-day all-cause and hypoglycemia-related readmission among patients with diabetic hypoglycemia include recent exposure to hospital/SNF/NH, adults <45 years, AAs, and several cardiovascular and

  4. Increased 30-Day Emergency Department Revisits Among Homeless Patients with Mental Health Conditions

    PubMed Central

    Lam, Chun Nok; Arora, Sanjay; Menchine, Michael

    2016-01-01

    Introduction Patients with mental health conditions frequently use emergency medical services. Many suffer from substance use and homelessness. If they use the emergency department (ED) as their primary source of care, potentially preventable frequent ED revisits and hospital readmissions can worsen an already crowded healthcare system. However, the magnitude to which homelessness affects health service utilization among patients with mental health conditions remains unclear in the medical community. This study assessed the impact of homelessness on 30-day ED revisits and hospital readmissions among patients presenting with mental health conditions in an urban, safety-net hospital. Methods We conducted a secondary analysis of administrative data on all adult ED visits in 2012 in an urban safety-net hospital. Patient demographics, mental health status, homelessness, insurance coverage, level of acuity, and ED disposition per ED visit were analyzed using multilevel modeling to control for multiple visits nested within patients. We performed multivariate logistic regressions to evaluate if homelessness moderated the likelihood of mental health patients’ 30-day ED revisits and hospital readmissions. Results Study included 139,414 adult ED visits from 92,307 unique patients (43.5±15.1 years, 51.3% male, 68.2% Hispanic/Latino). Nearly 8% of patients presented with mental health conditions, while 4.6% were homeless at any time during the study period. Among patients with mental health conditions, being homeless contributed to an additional 28.0% increase in likelihood (4.28 to 5.48 odds) of 30-day ED revisits and 38.2% increase in likelihood (2.04 to 2.82 odds) of hospital readmission, compared to non-homeless, non-mental health (NHNM) patients as the base category. Adjusted predicted probabilities showed that homeless patients presenting with mental health conditions have a 31.1% chance of returning to the ED within 30-day post discharge and a 3.7% chance of hospital

  5. The HOSPITAL score as a predictor of 30 day readmission in a retrospective study at a university affiliated community hospital

    PubMed Central

    2016-01-01

    Introduction Hospital readmissions are common, expensive, and a key target of the Medicare Value Based Purchasing (VBP) program. Risk assessment tools have been developed to identify patients at high risk of hospital readmission so they can be targeted for interventions aimed at reducing the rate of readmission. One such tool is the HOSPITAL score that uses seven readily available clinical variables to predict the risk of readmission within 30 days of discharge. The HOSPITAL score has been internationally validated in large academic medical centers. This study aims to determine if the HOSPITAL score is similarly useful in a moderate sized university affiliated hospital in the midwestern United States. Materials and Methods All adult medical patients discharged from the SIU-SOM Hospitalist service from Memorial Medical Center (MMC) from October 15, 2015 to March 16, 2016, were studied retrospectively to determine if the HOSPITAL score was a significant predictor of hospital readmission within 30 days. Results During the study period, 998 discharges were recorded for the hospitalist service. The analysis includes data for the 931 discharges. Patients who died during the hospital stay, were transferred to another hospital, or left against medical advice were excluded. Of these patients, 109 (12%) were readmitted to the same hospital within 30 days. The patients who were readmitted were more likely to have a length of stay greater than or equal to 5 days (55% vs. 41%, p = 0.005) and were more likely to have been admitted more than once to the hospital within the last year (100% vs. 49%, p < 0.001). A receiver operating characteristic evaluation of the HOSPITAL score for this patient population shows a C statistic of 0.77 (95% CI [0.73–0.81]), indicating good discrimination for hospital readmission. The Brier score for the HOSPITAL score in this setting was 0.10, indicating good overall performance. The Hosmer–Lemeshow goodness of fit test shows a χ2 value of 1

  6. The HOSPITAL score as a predictor of 30 day readmission in a retrospective study at a university affiliated community hospital

    PubMed Central

    2016-01-01

    Introduction Hospital readmissions are common, expensive, and a key target of the Medicare Value Based Purchasing (VBP) program. Risk assessment tools have been developed to identify patients at high risk of hospital readmission so they can be targeted for interventions aimed at reducing the rate of readmission. One such tool is the HOSPITAL score that uses seven readily available clinical variables to predict the risk of readmission within 30 days of discharge. The HOSPITAL score has been internationally validated in large academic medical centers. This study aims to determine if the HOSPITAL score is similarly useful in a moderate sized university affiliated hospital in the midwestern United States. Materials and Methods All adult medical patients discharged from the SIU-SOM Hospitalist service from Memorial Medical Center (MMC) from October 15, 2015 to March 16, 2016, were studied retrospectively to determine if the HOSPITAL score was a significant predictor of hospital readmission within 30 days. Results During the study period, 998 discharges were recorded for the hospitalist service. The analysis includes data for the 931 discharges. Patients who died during the hospital stay, were transferred to another hospital, or left against medical advice were excluded. Of these patients, 109 (12%) were readmitted to the same hospital within 30 days. The patients who were readmitted were more likely to have a length of stay greater than or equal to 5 days (55% vs. 41%, p = 0.005) and were more likely to have been admitted more than once to the hospital within the last year (100% vs. 49%, p < 0.001). A receiver operating characteristic evaluation of the HOSPITAL score for this patient population shows a C statistic of 0.77 (95% CI [0.73–0.81]), indicating good discrimination for hospital readmission. The Brier score for the HOSPITAL score in this setting was 0.10, indicating good overall performance. The Hosmer–Lemeshow goodness of fit test shows a χ2 value of 1

  7. Neighborhood Socioeconomic Disadvantage and 30 Day Rehospitalizations: An Analysis of Medicare Data

    PubMed Central

    Kind, Amy JH; Jencks, Steve; Brock, Jane; Yu, Menggang; Bartels, Christie; Ehlenbach, William; Greenberg, Caprice; Smith, Maureen

    2014-01-01

    Background Measures of socioeconomic disadvantage may enable improved targeting of programs to prevent rehospitalizations, but obtaining such information directly from patients can be difficult. Measures of US neighborhood socioeconomic disadvantage are more readily available, although rarely employed clinically. Objective To evaluate the association between neighborhood socioeconomic disadvantage at the census block-group level, as measured by Singh’s validated Area Deprivation Index (ADI), and 30-day rehospitalization. Design Retrospective cohort study Setting United States Patients Random 5% national sample of fee-for-service Medicare patients discharged with congestive heart failure, pneumonia or myocardial infarction, 2004–2009 (N = 255,744) Measurements 30-day rehospitalizations. Medicare data were linked to 2000 Census data to construct an ADI for each patient’s census block-group, which were then sorted into percentiles by increasing ADI. Relationships between neighborhood ADI grouping and rehospitalization were evaluated using multivariate logistic regression models, controlling for patient sociodemographics, comorbidities/severity, and index hospital characteristics. Results The 30-day rehospitalization rate did not vary significantly across the least disadvantaged 85% of neighborhoods, which had an average rehospitalization rate=21%. However, within the most disadvantaged 15% of neighborhoods, rehospitalization rates rose from 22% to 27% with worsening ADI. This relationship persisted after full adjustment, with the most disadvantaged neighborhoods having a rehospitalization risk (adjusted risk ratio = 1.09, confidence interval 1.05–1.12) similar to that of chronic pulmonary disease (1.06, 1.04–1.08) and greater than that of diabetes (0.95, 0.94–0.97). Limitations No direct markers of care quality, access Conclusions Residence within a disadvantaged US neighborhood is a rehospitalization predictor of magnitude similar to chronic pulmonary

  8. LBNP exercise protects aerobic capacity and sprint speed of female twins during 30 days of bed rest.

    PubMed

    Lee, Stuart M C; Schneider, Suzanne M; Boda, Wanda L; Watenpaugh, Donald E; Macias, Brandon R; Meyer, R Scott; Hargens, Alan R

    2009-03-01

    We have shown previously that treadmill exercise within lower body negative pressure (LBNPex) maintains upright exercise capacity (peak oxygen consumption, Vo(2peak)) in men after 5, 15, and 30 days of bed rest (BR). We hypothesized that LBNPex protects treadmill Vo(2peak) and sprint speed in women during a 30-day BR. Seven sets of female monozygous twins volunteered to participate. Within each twin set, one was randomly assigned to a control group (Con) and performed no countermeasures, and the other was assigned to an exercise group (Ex) and performed a 40-min interval (40-80% pre-BR Vo(2peak)) LBNPex (51 +/- 5 mmHg) protocol, plus 5 min of static LBNP, 6 days per week. Before and immediately after BR, subjects completed a 30.5-m sprint test and an upright graded treadmill test to volitional fatigue. These results in women were compared with previously reported reductions in Vo(2peak) and sprint speed in male twins after BR. In women, sprint speed (-8 +/- 2%) and Vo(2peak) (-6 +/- 2%) were not different after BR in the Ex group. In contrast, both sprint speed (-24 +/- 5%) and Vo(2peak) (-16 +/- 3%) were significantly less after BR in the Con group. The effect of BR on sprint speed and Vo(2peak) after BR was not different between women and men. We conclude that treadmill exercise within LBNP protects against BR-induced reductions in Vo(2peak) and sprint speed in women and should prove effective during long-duration spaceflight.

  9. Characterization of Flow Bench Engine Testing

    NASA Astrophysics Data System (ADS)

    Voris, Alex; Riley, Lauren; Puzinauskas, Paul

    2015-11-01

    This project was an attempt at characterizing particle image velocimetry (PIV) and swirl-meter test procedures. The flow direction and PIV seeding were evaluated for in-cylinder steady state flow of a spark ignition engine. For PIV seeding, both wet and dry options were tested. The dry particles tested were baby powder, glass particulate, and titanium dioxide. The wet particles tested were fogs created with olive oil, vegetable oil, DEHS, and silicon oil. The seeding was evaluated at 0.1 and 0.25 Lift/Diameter and at cylinder pressures of 10, 25 and 40 inches of H2O. PIV results were evaluated through visual and fluid momentum comparisons. Seeding particles were also evaluated based on particle size and cost. It was found that baby powder and glass particulate were the most effective seeding options for the current setup. The oil fogs and titanium dioxide were found to deposit very quickly on the mock cylinder and obscure the motion of the particles. Based on initial calculations and flow measurements, the flow direction should have a negligible impact on PIV and swirl-meter results. The characterizations found in this project will be used in future engine research examining the effects of intake port geometry on in-cylinder fluid motion and exhaust gas recirculation tolerances. Thanks to NSF site grant #1358991.

  10. Resource Prospector Propulsion System Cold Flow Testing

    NASA Technical Reports Server (NTRS)

    Williams, Hunter; Holt, Kim; Addona, Brad; Trinh, Huu

    2015-01-01

    Resource Prospector (RP) is a NASA mission being led by NASA Ames Research Center with current plans to deliver a scientific payload package aboard a rover to the lunar surface. As part of an early risk reduction activity, Marshall Space Flight Center (MSFC) and Johnson Space Flight Center (JSC) have jointly developed a government-version concept of a lunar lander for the mission. The spacecraft consists of two parts, the lander and the rover which carries the scientific instruments. The lander holds the rover during launch, cruise, and landing on the surface. Following terminal descent and landing the lander portion of the spacecraft become dormant after the rover embarks on the science mission. The lander will be equipped with a propulsion system for lunar descent and landing, as well as trajectory correction and attitude control maneuvers during transit to the moon. Hypergolic propellants monomethyl hydrazine and nitrogen tetroxide will be used to fuel sixteen 70-lbf descent thrusters and twelve 5-lbf attitude control thrusters. A total of four metal-diaphragm tanks, two per propellant, will be used along with a high-pressure composite-overwrapped pressure vessel for the helium pressurant gas. Many of the major propulsion system components are heritage missile hardware obtained by NASA from the Air Force. In parallel with the flight system design activities, a simulated propulsion system based on flight drawings was built for conducting a series of water flow tests to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes such as system priming, waterhammer, and crucial mission duty cycles. The primary objective of the cold flow testing was to simulate the RP propulsion system fluid flow operation through water flow testing and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. All design and

  11. 17 CFR 240.3a55-2 - Indexes underlying futures contracts trading for fewer than 30 days.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... contracts trading for fewer than 30 days. 240.3a55-2 Section 240.3a55-2 Commodity and Securities Exchanges... Indexes underlying futures contracts trading for fewer than 30 days. (a) An index on which a contract of sale for future delivery is trading on a designated contract market, registered derivatives...

  12. 78 FR 69428 - Submission for OMB Review; 30-Day Comment Request: Cancer Trials Support Unit (CTSU) (NCI)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-Day Comment Request: Cancer... and Budget (OMB) a request for review and approval of the information collection listed below. This... of this notice is to allow an additional 30 days for public comment. The National Cancer...

  13. 78 FR 65696 - 30-Day Notice of Proposed Information Collection: Housing Finance Agency Risk-Sharing Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... October 25, 2013 at 78 FR 64145 HUD published a 30 day notice of proposed information collection. This... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Housing Finance Agency Risk-Sharing... Collection Title of Information Collection: Housing Finance Agency Risk- Sharing Program. OMB Approval...

  14. 76 FR 6794 - 30-Day Submission Period for Requests for ONC-Approved Accreditor (ONC-AA) Status

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-08

    ... Program for Health Information Technology, 76 FR 1262 (Jan. 7, 2011) (the ``Permanent Certification... HUMAN SERVICES 30-Day Submission Period for Requests for ONC-Approved Accreditor (ONC-AA) Status AGENCY... ONC-Approved Accreditor (ONC-AA) status. Authority: 42 U.S.C. 300jj-11. DATES: The 30-day...

  15. 78 FR 66040 - 30-Day Notice of Proposed Information Collection: HUD-Owned Real Estate-Sales Contract and Addendums

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... October 25, 2013 at 78 FR 64145, HUD inadvertently published a 30 day notice of proposed information... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: HUD-Owned Real Estate--Sales... Housing and Urban Development, 451 7th Street SW., Washington, DC 20410; email Colette Pollard at...

  16. Incidence And Risk Factors For 30-Day Readmissions After Hip Fracture Surgery

    PubMed Central

    Martin, Christopher T; Gao, Yubo; Pugely, Andrew J.

    2016-01-01

    Background Unplanned hospital readmission following orthopedic procedures results in significant expenditures for the Medicare population. In order to reduce expenditures, hospital readmission has become an important quality metric for Medicare patients. The purpose of the present study is to determine the incidence and risk factors for 30-day readmissions after hip fracture surgery. Methods Patients over the age of 18 years who underwent hip fracture surgery, including open reduction internal fixation (ORIF), intramedullary nailing, hemi-arthroplasty, or total hip arthroplasty, between the years 2012 and 2013 were identified from the American College of Surgeons National Surgical Quality improvement Program (NSQIP) database. Overall, 17,765 patients were identified. Univariate and multivariate analyses were performed in order to determine patient and surgical factors associated with 30-day readmission. Results There were 1503 patients (8.4%) readmitted within 30-days of their index procedure. Of the patients with a reason listed for readmission, 27.4% were for procedurally related reasons, including wound complications (16%), peri-prosthetic fractures (4.5%) and prosthetic dislocations (6%). 72.6% of readmissions were for medical reasons, including sepsis (7%), pneumonia (14%), urinary tract infection (6.3%), myocardial infarction (2.7%), renal failure (2.7%), and stroke (2.3%). In the subsequent multivariate analysis, pre-operative dyspnea, COPD, hypertension, disseminated cancer, a bleeding disorder, pre-operative hematocrit of <36, pre-operative creatinine of >1.2, an ASA class of 3 or 4, and the operative procedure type were each independently associated with readmissions risk (p<0.05 for each). Conclusions The overall rate of readmission following hip fracture surgery was moderate. Surgeons should consider discharge optimization in the at risk cohorts identified here, particularly patients with multiple medical comorbidities or an elevated ASA class, and

  17. Postoperative Morbidity by Procedure and Patient Factors Influencing Major Complications Within 30 Days Following Shoulder Surgery

    PubMed Central

    Shields, Edward; Iannuzzi, James C.; Thorsness, Robert; Noyes, Katia; Voloshin, Ilya

    2014-01-01

    Background: Little data are available to prioritize quality improvement initiatives in shoulder surgery. Purpose: To stratify the risk for 30-day postoperative morbidity in commonly performed surgical procedures about the shoulder completed in a hospital setting and to determine patient factors associated with major complications. Study Design: Cohort study; Level of evidence, 3. Methods: This retrospective study utilized the National Surgical Quality Improvement Program (NSQIP) database from the years 2005 to 2010. Using Current Procedural Terminology codes, the database was queried for shoulder cases that were divided into 7 groups: arthroscopy without repair; arthroscopy with repair; arthroplasty; clavicle/acromioclavicular joint (AC) open reduction and internal fixation (ORIF)/repair; ORIF of proximal humeral fracture; open tendon release/repair; and open shoulder stabilization. The primary end point was any major complication, with secondary end points of incisional infection, return to the operating room, and venothromboembolism (VTE), all within 30 days of surgery. Results: Overall, 11,086 cases were analyzed. The overall major complication rate was 2.1% (n = 234). Factors associated with major complications on multivariate analysis included: procedure performed (P < .001), emergency case (P < .001), pulmonary comorbidity (P < .001), preoperative blood transfusion (P = .033), transfer from an outside institution (P = .03), American Society of Anesthesiologists (ASA) score (P = .006), wound class (P < .001), dependent functional status (P = .027), and age older than 60 years (P = .01). After risk adjustment, open shoulder stabilization was associated with the greatest risk of major complications relative to arthroscopy without repair (odds ratio [OR], 5.56; P = .001), followed by ORIF of proximal humerus fracture (OR, 4.90; P < .001) and arthroplasty (OR, 4.40; P < .001). These 3 groups generated over 60% of all major complications. Open shoulder

  18. SSME hot gas manifold flow comparison test

    NASA Technical Reports Server (NTRS)

    Cox, G. B., Jr.; Dill, C. C.

    1988-01-01

    An account is given of the High Pressure Fuel Turbopump (HPFT) component of NASA's Alternate Turbopump Development effort, which is aimed at the proper aerodynamic integration of the current Phase II three-duct SSME Hot Gas Manifold (HGM) and the future 'Phase II-plus' two-duct HGM. Half-scale water flow tests of both HGM geometries were conducted to provide initial design data for the HPFT. The results reveal flowfield results and furnish insight into the performance differences between the two HGM flowpaths. Proper design of the HPFT can potentially secure significant flow improvements in either HGM configuration.

  19. The Gravity of LBNP Exercise: Lessons Learned from Identical Twins in Bed for 30 Days

    NASA Technical Reports Server (NTRS)

    Hargens, Alan R.; Groppo, Eli R.; Lee, Stuart M. C.; Watenpaugh, Donald; Schneider, Suzanne; O'Leary, Deborah; Smith, Scott M.; Steinbach, Gregory C.; Tanaka, Kunihiko; Kimura, Shinji; Meyer, R. Scott

    2002-01-01

    Microgravity leads to cardiovascular deconditioning in humans, which is manifested by post-flight reduction of orthostatic tolerance and upright exercise capacity. During upright posture on Earth, blood pressures are greater in the feet than at heart or head levels due to gravity's effects on columns of blood in the body. During exposure to Microgravity, all gravitational blood pressures disappear. Presently, there is no exercise hardware available for space flight to provide gravitational blood pressures to tissues of the lower body. We hypothesized that 40 minutes of supine treadmill running per day in a LBNP chamber at 1.0 to 1.2 body weight (approximately 50 - 60 mm Hg LBNP) with a 5 min resting, nonexercise LBNP exposure at 50 mm Hg after the exercise session will maintain aerobic fitness orthostatic tolerance, and selected parameters of musculoskeletal function during 30 days of bed rest (simulated microgravity). This paper is an interim report of some of our findings on 16 subjects.

  20. Bone metabolism and nutritional status during 30-day head-down-tilt bed rest.

    PubMed

    Morgan, Jennifer L L; Zwart, Sara R; Heer, Martina; Ploutz-Snyder, Robert; Ericson, Karen; Smith, Scott M

    2012-11-01

    Bed rest studies provide an important tool for modeling physiological changes that occur during spaceflight. Markers of bone metabolism and nutritional status were evaluated in 12 subjects (8 men, 4 women; ages 25-49 yr) who participated in a 30-day -6° head-down-tilt diet-controlled bed rest study. Blood and urine samples were collected twice before, once a week during, and twice after bed rest. Data were analyzed using a mixed-effects linear regression with a priori contrasts comparing all days to the second week of the pre-bed rest acclimation period. During bed rest, all urinary markers of bone resorption increased ~20% (P < 0.001), and serum parathyroid hormone decreased ~25% (P < 0.001). Unlike longer (>60 days) bed rest studies, neither markers of oxidative damage nor iron status indexes changed over the 30 days of bed rest. Urinary oxalate excretion decreased ~20% during bed rest (P < 0.001) and correlated inversely with urinary calcium (R = -0.18, P < 0.02). These data provide a broad overview of the biochemistry associated with short-duration bed rest studies and provide an impetus for using shorter studies to save time and costs wherever possible. For some effects related to bone biochemistry, short-duration bed rest will fulfill the scientific requirements to simulate spaceflight, but other effects (antioxidants/oxidative damage, iron status) do not manifest until subjects are in bed longer, in which case longer studies or other analogs may be needed. Regardless, maximizing research funding and opportunities will be critical to enable the next steps in space exploration. PMID:22995395

  1. Wing Leading Edge Joint Laminar Flow Tests

    NASA Technical Reports Server (NTRS)

    Drake, Aaron; Westphal, Russell V.; Zuniga, Fanny A.; Kennelly, Robert A., Jr.; Koga, Dennis J.

    1996-01-01

    An F-104G aircraft at NASA's Dryden Flight Research Center has been equipped with a specially designed and instrumented test fixture to simulate surface imperfections of the type likely to be present near the leading edge on the wings of some laminar flow aircraft. The simulated imperfections consisted of five combinations of spanwise steps and gaps of various sizes. The unswept fixture yielded a pressure distribution similar to that of some laminar flow airfoils. The experiment was conducted at cruise conditions typical for business-jets and light transports: Mach numbers were in the range 0.5-0.8, and unit Reynolds numbers were 1.5-2.5 million per foot. Skin friction measurements indicated that laminar flow was often maintained for some distance downstream of the surface imperfections. Further work is needed to more precisely define transition location and to extend the experiments to swept-wing conditions and a broader range of imperfection geometries.

  2. Sultan - forced flow, high field test facility

    SciTech Connect

    Horvath, I.; Vecsey, G.; Weymuth, P.; Zellweger, J.

    1981-09-01

    Three European laboratories: CNEN (Frascati, I) ECN (Petten, NL) and SIN (Villigen, CH) decided to coordinate their development efforts and to install a common high field forced flow test facility at Villigen Switzerland. The test facility SULTAN (Supraleiter Testanlage) is presently under construction. As a first step, an 8T/1m bore solenoid with cryogenic periphery will be ready in 1981. The cryogenic system, data acquisition system and power supplies which are contributed by SIN are described. Experimental feasibilities, including cooling, and instrumentation are reviewed. Progress of components and facility construction is described. Planned extension of the background field up to 12T by insert coils is outlined. 5 refs.

  3. 77 FR 73731 - 30-Day Notice of Proposed Information Collection: Application Under the Hague Convention on the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ... organizations. The purpose of this Notice is to allow 30 days for public comment. DATES: Submit comments directly to the Office of Management and Budget (OMB) up to January 10, 2013. ADDRESSES: Direct comments...

  4. 78 FR 65697 - 30-Day Notice of Proposed Information Collection: Public Housing, Contracting With Resident-Owned...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Public Housing, Contracting With...: Colette Pollard, Reports Management Officer, QDAM, Department of Housing and Urban Development, 451...

  5. Examination of hospital characteristics and patient quality outcomes using four inpatient quality indicators and 30-day all-cause mortality.

    PubMed

    Carretta, Henry J; Chukmaitov, Askar; Tang, Anqi; Shin, Jihyung

    2013-01-01

    The study objective was to examine hospital mortality outcomes and structure using 2008 patient-level discharges from general community hospitals. Discharges from Florida administrative files were merged to the state mortality registry. A cross-sectional analysis of inpatient mortality was conducted using Inpatient Quality Indicators (IQIs) for acute myocardial infarction (AMI), congestive heart failure (CHF), stroke, pneumonia, and all-payer 30-day postdischarge mortality. Structural characteristics included bed size, volume, ownership, teaching status, and system affiliation. Outcomes were risk adjusted using 3M APR-DRG. Volume was inversely correlated with AMI, CHF, stroke, and 30-day mortality. Similarities and differences in the direction and magnitude of the relationship of structural characteristics to 30-day postdischarge and IQI mortality measures were observed. Hospital volume was inversely correlated with inpatient mortality outcomes. Other hospital characteristics were associated with some mortality outcomes. Further study is needed to understand the relationship between 30-day postdischarge mortality and hospital quality.

  6. A UK general practice population cohort study investigating the association between lipid lowering drugs and 30-day mortality following medically attended acute respiratory illness

    PubMed Central

    Joshi, Roshni; Myles, Puja R.

    2016-01-01

    Background. Cholesterol lowering drugs HMG-CoA reductase inhibitors (statins) and PPARα activators (fibrates) have been shown to reduce host inflammation via non-disease specific immunomodulatory mechanisms. Recent studies suggest that commonly prescribed drugs in general practice, statins and fibrates, may be beneficial in influenza-like illness related mortality. This retrospective cohort study examines the association between two lipid lowering drugs, statins and fibrates, and all-cause 30-day mortality following a medically attended acute respiratory illness (MAARI). Methods. Primary care patient data were retrospectively extracted from the UK Clinical Practice Research Datalink (CPRD) database. The sample comprised 201,179 adults aged 30 years or older experiencing a MAARI episode. Patient exposure to statins or fibrates was coded as separate dichotomous variables and deemed current if the most recent GP prescription was issued in the 30 days prior to MAARI diagnosis. Multivariable logistic regression and Cox regression were used for analyses. Adjustment was carried out for chronic lung disease, heart failure, metformin and glitazones, comorbidity burden, socio-demographic and lifestyle variables such as smoking status and body mass index (BMI). Statistical interaction tests were carried out to check for effect modification by gender, body mass index, smoking status and comorbidity. Results. A total of 1,096 (5%) patients died within the 30-day follow up period. Of this group, 213 (19.4%) were statin users and 4 (0.4%) were fibrate users. After adjustment, a significant 35% reduction in odds [adj OR; 0.65 (95% CI [0.52–0.80])] and a 33% reduction in the hazard [adj HR: 0.67 (95% CI [0.55–0.83])] of all-cause 30-day mortality following MAARI was observed in statin users. A significant effect modification by comorbidity burden was observed for the association between statin use and MAARI-related mortality. Fibrate use was associated with a non

  7. A UK general practice population cohort study investigating the association between lipid lowering drugs and 30-day mortality following medically attended acute respiratory illness.

    PubMed

    Joshi, Roshni; Venkatesan, Sudhir; Myles, Puja R

    2016-01-01

    Background. Cholesterol lowering drugs HMG-CoA reductase inhibitors (statins) and PPARα activators (fibrates) have been shown to reduce host inflammation via non-disease specific immunomodulatory mechanisms. Recent studies suggest that commonly prescribed drugs in general practice, statins and fibrates, may be beneficial in influenza-like illness related mortality. This retrospective cohort study examines the association between two lipid lowering drugs, statins and fibrates, and all-cause 30-day mortality following a medically attended acute respiratory illness (MAARI). Methods. Primary care patient data were retrospectively extracted from the UK Clinical Practice Research Datalink (CPRD) database. The sample comprised 201,179 adults aged 30 years or older experiencing a MAARI episode. Patient exposure to statins or fibrates was coded as separate dichotomous variables and deemed current if the most recent GP prescription was issued in the 30 days prior to MAARI diagnosis. Multivariable logistic regression and Cox regression were used for analyses. Adjustment was carried out for chronic lung disease, heart failure, metformin and glitazones, comorbidity burden, socio-demographic and lifestyle variables such as smoking status and body mass index (BMI). Statistical interaction tests were carried out to check for effect modification by gender, body mass index, smoking status and comorbidity. Results. A total of 1,096 (5%) patients died within the 30-day follow up period. Of this group, 213 (19.4%) were statin users and 4 (0.4%) were fibrate users. After adjustment, a significant 35% reduction in odds [adj OR; 0.65 (95% CI [0.52-0.80])] and a 33% reduction in the hazard [adj HR: 0.67 (95% CI [0.55-0.83])] of all-cause 30-day mortality following MAARI was observed in statin users. A significant effect modification by comorbidity burden was observed for the association between statin use and MAARI-related mortality. Fibrate use was associated with a non

  8. Scaled Rocket Testing in Hypersonic Flow

    NASA Technical Reports Server (NTRS)

    Dufrene, Aaron; MacLean, Matthew; Carr, Zakary; Parker, Ron; Holden, Michael; Mehta, Manish

    2015-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was strongly based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Detailed base heating results are outside of the scope of the current work, rather test methodology and techniques are presented along with broader applicability toward scaled rocket testing in supersonic and hypersonic flow.

  9. Effect of 30-day orbital flight BION M1 on excretion of expired endogenous CO in mice

    NASA Astrophysics Data System (ADS)

    Shulagin, Yury; Tatarkin, Sergey; Dyachenko, Alexander

    It is known that increased destruction of hem structures is accompanied by increase of the endogenous carbon monoxide excretion rate with respiration (VCO). Changes VCO preceded the observed changes in the blood composition [D’yachenko A. et al., 2010]. Changes in blood composition, i.e. rise of red blood cells content and reduction of reticulocytes content was detected after a 12-day orbital flight (OF) in mice C57BL/6 [Gridley D.et al., 2003]. The purpose of this study was to investigate the effect of 30-day OF on excretion of endogenous CO. The method and apparatus for simultaneous measurement of VCO, and O2 and CO2 exchange were developed. The research consisted of three parts: 1). Measurement of VCO in five C57BL/6 mice after 30-day OF on the Russian satellite BION M1. 2). Measurement of VCO in six C57BL/6 mice after 30-day ground-based experiment (GBE) with simulated flight telemetry environment of BION M1. 3). Measurement of VCO in seven C57BL/6 mice in vivarium The results: Mice weight after OF was 24.3+-3.3 (mean +-SD) with minimal weight 18.1 g, and maximal weight 29.9 g. Vivarium mice weight was 27.0+-1.8 g. KGE mice weight was 25.0+-1.3 g. Mice age in all three groups was the same. We measured and estimated VCO and total CO excretion (MCO) for two gas mixtures ventilated mouse camera: atmospheric CO-contained air and then CO-free air(30 min). The results showed that the average MCO allocated GBE and vivarium mice did not significantly differ. Average MCO in mice after OF was significantly higher then in vivarium group (T=-2,74; p=0.02). MCO after GBE was between the vivarium and OF groups. MCO in OF and KGE groups did not differ ( T=-1,93; p=0,085). Blood tests in mice after OF was not carried out, because the recovery after the OF was studied in this group. The largest excretion of CO was observed in a mouse N39 after the OF. The weight of this mouse was only 18.1 g, i.e. much less than mean weight. Increase of VCO in food-restricted animal is known

  10. Unplanned 30-Day Readmissions in a General Internal Medicine Hospitalist Service at a Comprehensive Cancer Center

    PubMed Central

    Manzano, Joanna-Grace M.; Gadiraju, Sahitya; Hiremath, Adarsh; Lin, Heather Yan; Farroni, Jeff; Halm, Josiah

    2015-01-01

    Purpose: Hospital readmissions are considered by the Centers for Medicare and Medicaid as a metric for quality of health care delivery. Robust data on the readmission profile of patients with cancer are currently insufficient to determine whether this measure is applicable to cancer hospitals as well. To address this knowledge gap, we estimated the unplanned readmission rate and identified factors influencing unplanned readmissions in a hospitalist service at a comprehensive cancer center. Methods: We retrospectively analyzed unplanned 30-day readmission of patients discharged from the General Internal Medicine Hospitalist Service at a comprehensive cancer center between April 1, 2012, and September 30, 2012. Multiple independent variables were studied using univariable and multivariable logistic regression models, with generalized estimating equations to identify risk factors associated with readmissions. Results: We observed a readmission rate of 22.6% in our cohort. The median time to unplanned readmission was 10 days. Unplanned readmission was more likely in patients with metastatic cancer and those with three or more comorbidities. Patients discharged to hospice were less likely to be readmitted (all P values < .01). Conclusion: We observed a high unplanned readmission rate among our population of patients with cancer. The risk factors identified appear to be related to severity of illness and open up opportunities for improving coordination with primary care physicians, oncologists, and other specialists to manage comorbidities, or perhaps transition appropriate patients to palliative care. Our findings will be instrumental for developing targeted interventions to help reduce readmissions at our hospital. Our data also provide direction for appropriate application of readmission quality measures in cancer hospitals. PMID:26152375

  11. Marked Improvement in 30-Day Mortality among Elderly Inpatients and Outpatients with Community-Acquired Pneumonia

    PubMed Central

    Ruhnke, Gregory W.; Coca-Perraillon, Marcelo; Kitch, Barrett T.; Cutler, David M.

    2011-01-01

    BACKGROUND Community-acquired pneumonia is the most common infectious cause of death in the United States. Over the last two decades, patient characteristics and clinical care have changed. To understand the impact of these changes, we quantified incidence and mortality trends among elderly adults. METHODS We used Medicare claims to identify episodes of pneumonia, based on a validated combination of diagnosis codes. Comorbidities were ascertained using the diagnosis codes located on a one-year look back. Trends in patient characteristics and site of care were compared. The association between year of pneumonia episode and 30-day mortality was then evaluated by logistic regression, with adjustment for age, sex, and comorbidities. RESULTS We identified 2,654,955 cases of pneumonia from 1987–2005. During this period, the proportion treated as inpatients decreased, the proportion aged >= 80 increased, and the frequency of many comorbidities rose. Adjusted incidence increased to 3096 episodes per 100,000 population in 1999, with some decline thereafter. Age/sex-adjusted mortality decreased from 13.5% to 9.7%, a relative reduction of 28.1%. Compared to 1987, the risk of mortality declined through 2005 (adjusted odds ratio, 0.46; 95% confidence interval, 0.44 to 0.47). This result was robust to a restriction on comorbid diagnoses assessing for the results' sensitivity to increased coding. CONCLUSIONS These findings show a marked mortality reduction over time in community-acquired pneumonia patients. We hypothesize that increased pneumococcal and influenza vaccination rates as well as wider use of guideline-concordant antibiotics explain a large portion of this trend. PMID:21295197

  12. ICFT: An initial closed-loop flow test of the Fenton Hill Phase II HDR reservoir

    SciTech Connect

    Dash, Z.V.; Aguilar, R.G.; Dennis, B.R.; Dreesen, D.S.; Fehler, M.C.; Hendron, R.H.; House, L.S.; Ito, H.; Kelkar, S.M.; Malzahn, M.V.

    1989-02-01

    A 30-day closed-loop circulation test of the Phase II Hot Dry Rock reservoir at Fenton Hill, New Mexico, was conducted to determine the thermal, hydraulic, chemical, and seismic characteristics of the reservoir in preparation for a long-term energy-extraction test. The Phase II heat-extraction loop was successfully tested with the injection of 37,000 m/sup 3/ of cold water and production of 23,300 m/sup 3/ of hot water. Up to 10 MW/sub t/ was extracted when the production flow rate reached 0.0139 m/sup 3//s at 192/degree/C. By the end of the test, the water-loss rate had decreased to 26% and a significant portion of the injected water was recovered; 66% during the test and an additional 20% during subsequent venting. Analysis of thermal, hydraulic, geochemical, tracer, and seismic data suggests the fractured volume of the reservoir was growing throughout the test. 19 refs., 64 figs., 19 tabs.

  13. Air flow testing on aerodynamic truck

    NASA Technical Reports Server (NTRS)

    1981-01-01

    This photograph illustrates a standard passenger van modified at the Dryden Flight Research Center to investigate the aerodynamics of trucks. The resulting vehicle--re-fashioned with sheet metal--resembled a motor home, with rounded vertical corners on the vehicle's front and rear sections. For subsequent tests, researchers installed a 'boat tail' structure, shown in the photograph. During a decade spanning the 1970s and 1980s, Dryden researchers conducted tests to determine the extent to which adjustments in the shape of trucks reduced aerodynamic drag and improved efficiency. During the tests, the vehicle's sides were fitted with tufts, or strings, that showed air flow. The investigators concluded that rounding the vertical corners front and rear reduced drag by 40 percent, yet decreased the vehicle's internal volume by only 1.3 percent. Rounding both the vertical and horizontal corners cut drag by 54 percent, resulting in a three percent loss of internal volume. A second group of tests added a faired underbody and a boat tail, the latter feature resulting in drag reduction of about 15 percent.

  14. 30-day Mortality after Bariatric Surgery: Independently Adjudicated Causes of Death in the Longitudinal Assessment of Bariatric Surgery

    PubMed Central

    Smith, Mark D.; Patterson, Emma; Wahed, Abdus S.; Belle, Steven H.; Berk, Paul D.; Courcoulas, Anita P.; Dakin, Gregory F.; Flum, David R.; Machado, Laura; Mitchell, James E.; Pender, John; Pomp, Alfons; Pories, Walter; Ramanathan, Ramesh; Schrope, Beth; Staten, Myrlene; Ude, Akuezunkpa; Wolfe, Bruce M.

    2011-01-01

    Purpose Mortality following bariatric surgery is a rare event in contemporary series, making it difficult for any single center to draw meaningful conclusions as to cause of death. Nevertheless, much of the published mortality data come from single center case series and reviews of administrative databases. These sources tend to produce lower mortality estimates than those obtained from controlled clinical trials. Furthermore, information about the causes of death and how they were determined is not always available. The aim of the present report is to describe in detail all deaths occurring within 30-days of surgery in the Longitudinal Assessment of Bariatric Surgery (LABS). Methods LABS is a 10-center observational cohort study of bariatric surgical outcomes. Data were collected prospectively for bariatric surgeries performed between March 2005 and April 2009. All deaths occurring within 30-days of surgery were identified, and cause of death assigned by an independent Adjudication Subcommittee, blinded to operating surgeon and site. Results 6118 patients underwent primary bariatric surgery. 18 deaths (0.3%) occurred within 30-days of surgery. The most common cause of death was sepsis (33% of deaths), followed by cardiac causes (28%) and pulmonary embolism (17%). For one patient cause of death could not be determined despite examination of all available information. Conclusions This study confirms the low 30-day mortality rate following bariatric surgery. The recognized complications of anastomotic leak, cardiac events, and pulmonary emboli accounted for the majority of 30-day deaths. PMID:21866378

  15. Bion M1. Peculiarities of life activities of microbes in 30-day spaceflight

    NASA Astrophysics Data System (ADS)

    Viacheslav, Ilyin; Korshunov, Denis; Morozova, Julia; Voeikova, Tatiana; Tyaglov, Boris; Novikova, Liudmila; Krestyanova, Irina; Emelyanova, Lydia

    The aim of this work was to analyze the influence of space flight factors ( SFF) to microorganism strains , exposed inside unmanned spacecraft Bion M-1 during the 30- day space flight. Objectives of the work - the study of the influence of the SFF exchange chromosomal DNA in crosses microorganisms of the genus Streptomyces; the level of spontaneous phage induction of lysogenic strains fS31 from Streptomyces lividans 66 and Streptomyces coelicolor A3 ( 2 ) on the biosynthesis of the antibiotic tylosin strain of Streptomyces fradiae; survival electrogenic bacteria Shewanella oneidensis MR- 1 is used in the microbial fuel cell As a result of this work it was found that the SFF affect the exchange of chromosomal DNA by crossing strains of Streptomyces. Was detected polarity crossing , expressed in an advantageous contribution chromosome fragment of one of the parent strains in recombinant offspring. This fact may indicate a more prolonged exposure of cells in microgravity and , as a consequence, the transfer of longer fragments of chromosomal DNA This feature is the transfer of genetic material in microgravity could lead to wider dissemination and horizontal transfer of chromosomal and plasmid DNA of symbiotic microflora astronauts and other strains present in the spacecraft. It was shown no effect on the frequency of recombination PCF and the level of mutation model reversion of auxotrophic markers to prototrophy It was demonstrated that PCF increase the level of induction of cell actinophage fS31 lysogenic strain of S. lividans 66, but did not affect the level of induction of this phage cells S. coelicolor A3 ( 2). It is shown that the lower the level of synthesis PCF antibiotic aktinorodina (actinorhodin) in lysogenic strain S. coelicolor A3 ( 2). 66 Strains of S. lividans and S. coelicolor A3 ( 2 ) can be used as a biosensor for studying the effect on microorganisms PCF It is shown that the effect of the PCF reduces synthesis of tylosin and desmicosyn S. fradiae at

  16. 77 FR 38290 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ... and Web). Usability Test.. 40 1 1.5 60 Confidentiality 40 1 5/60 3.3 Agreement. Remote usability, prototype Screener........ 200 1 10/60 and concept testing. Web-test........ 50 1 1 50 Confidentiality 50 1... message testing.... Screener........ 0 0 0 0 Web-test........ 115 1 1 115 Confidentiality 115 1 5/60...

  17. Use of mortality within 30 days of a COPD hospitalisation as a measure of COPD care in UK hospitals.

    PubMed

    Walker, P P; Thompson, E; Crone, H; Flatt, G; Holton, K; Hill, S L; Pearson, M G

    2013-10-01

    Mortality rate has been proposed as a metric of hospital chronic obstructive pulmonary disease (COPD) care in light of variation seen in national COPD audits. Using Hospital Episode Statistics (hospital 'coding') we examined 30-day mortality after COPD hospitalisation in 150 UK hospitals during 2006-2007 and 2007-2008. Mean and median 30-day mortalities were similar each year but the coefficient of variation was >20% and hospitals could change from a low or high quartile to the median by chance. We could not detect any reasons for hospitals being at the extremes. 30-day mortality after COPD hospitalisation is a complex variable and unlikely to be useful as a primary annual COPD metric.

  18. Here are considerations in evaluating Russian flow tests, reservoir performance

    SciTech Connect

    Krug, J.A. ); Connelly, W. )

    1992-12-28

    Flow test data contain some of the most important information for evaluation of a field. As part of the Russian evaluation process, research wells are extensively tested. Three types of well tests are conducted: drillstem tests, production flow test (if the well flows to the surface), and rising head test (if the well will not flow to the surface). Drillstem tests are run in the open hole across potential pay zones. After casing is run, wells are flow tested with multiple-rate tests, and the bottom hole pressures are recorded during the build-up periods. Results of the tests are summarized in test reports, on net pay maps, and on logs. The results from these tests include reservoir pressure, reservoir temperature, formation permeability, productivity index, and damage ratio. This paper reports that this information provides the basis for estimating production capacities and future reservoirs.

  19. Optical Air Flow Measurements for Flight Tests and Flight Testing Optical Air Flow Meters

    NASA Technical Reports Server (NTRS)

    Jentink, Henk W.; Bogue, Rodney K.

    2005-01-01

    Optical air flow measurements can support the testing of aircraft and can be instrumental to in-flight investigations of the atmosphere or atmospheric phenomena. Furthermore, optical air flow meters potentially contribute as avionics systems to flight safety and as air data systems. The qualification of these instruments for the flight environment is where we encounter the systems in flight testing. An overview is presented of different optical air flow measurement techniques applied in flight and what can be achieved with the techniques for flight test purposes is reviewed. All in-flight optical airflow velocity measurements use light scattering. Light is scattered on both air molecules and aerosols entrained in the air. Basic principles of making optical measurements in flight, some basic optical concepts, electronic concepts, optoelectronic interfaces, and some atmospheric processes associated with natural aerosols are reviewed. Safety aspects in applying the technique are shortly addressed. The different applications of the technique are listed and some typical examples are presented. Recently NASA acquired new data on mountain rotors, mountain induced turbulence, with the ACLAIM system. Rotor position was identified using the lidar system and the potentially hazardous air flow profile was monitored by the ACLAIM system.

  20. Counter-Flow Cooling Tower Test Cell

    NASA Astrophysics Data System (ADS)

    Dvořák, Lukáš; Nožička, Jiří

    2014-03-01

    The article contains a design of a functional experimental model of a cross-flow mechanical draft cooling tower and the results and outcomes of measurements. This device is primarily used for measuring performance characteristics of cooling fills, but with a simple rebuild, it can be used for measuring other thermodynamic processes that take part in so-called wet cooling. The main advantages of the particular test cell lie in the accuracy, size, and the possibility of changing the water distribution level. This feature is very useful for measurements of fills of different heights without the influence of the spray and rain zone. The functionality of this test cell has been verified experimentally during assembly, and data from the measurement of common film cooling fills have been compared against the results taken from another experimental line. For the purpose of evaluating the data gathered, computational scripts were created in the MATLAB numerical computing environment. The first script is for exact calculation of the thermal balance of the model, and the second is for determining Merkel's number via Chebyshev's method.

  1. 46 CFR 162.018-7 - Flow rating tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-7 Flow rating tests. (a) Flow rating of valves shall be conducted in accordance with UG-131 of section VIII of... 46 Shipping 6 2010-10-01 2010-10-01 false Flow rating tests. 162.018-7 Section 162.018-7...

  2. 46 CFR 162.018-7 - Flow rating tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-7 Flow rating tests. (a) Flow rating of valves shall be conducted in accordance with UG-131 of section VIII of... 46 Shipping 6 2011-10-01 2011-10-01 false Flow rating tests. 162.018-7 Section 162.018-7...

  3. 78 FR 20329 - Submission for OMB review; 30-day Comment Request: A Generic Submission for Formative Research...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-04

    ... October 1, 1995, unless it displays a currently valid OMB control number. Direct Comments to OMB: Written... having their full effect if received within 30-days of the date of this publication. FOR FURTHER... be requested in writing. Proposed Collection: A Generic Submission For Formative Research,...

  4. 75 FR 39577 - 30-Day Notice of Intention To Request Clearance of Collection of Information; Opportunity for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ... comments on these information collection requirements on January 29, 2010 (75 FR 4838). The comment period... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF THE INTERIOR National Park Service 30-Day Notice of Intention To Request Clearance of Collection of...

  5. 75 FR 8101 - 30-Day Federal Register Notice of Intention To Request Clearance of Collection of Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... Register on Wednesday, November 4, 2009 (74 FR 57188). The comment period closed on January 4, 2010. No... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF THE INTERIOR National Park Service 30-Day Federal Register Notice of Intention To Request Clearance of Collection...

  6. 78 FR 64145 - 30-Day Notice of Proposed Information Collection: HUD-Owned Real Estate-Sales Contract and Addendums

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: HUD-Owned Real Estate--Sales..., Office of Management and Budget, New Executive Office Building, Washington, DC 20503; fax: 202-395-5806... Collection: HUD-Owned Real Estate--Sales Contract and Addendums. OMB Approval Number: 2502-0306. Type...

  7. 75 FR 32961 - 30-Day Federal Register Notice of Intention To Request Clearance of Collection of Information...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... collection Office of Management and Budget (OMB) Control 1024-0231. The OMB has up to 60 days to approve or... consideration, OMB should receive public comments within 30 days of the date on which this notice is published... solicit comments on this proposed information collection on April 5, 2010 (75 FR 17152-17153). No...

  8. 78 FR 55264 - Submission for OMB Review; 30-Day Comment Request: Awareness and Beliefs About Cancer Survey...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-Day Comment Request: Awareness and Beliefs About Cancer Survey, National Cancer Institute (NCI) SUMMARY: Under the provisions of... submitted to the Office of Management and Budget (OMB) a request to review and approve the...

  9. 78 FR 64145 - 30-Day Notice of Proposed Information Collection: Housing Finance Agency Risk-Sharing Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Housing Finance Agency Risk-Sharing..., 2013. A. Overview of Information Collection Title of Information Collection: Housing Finance Agency... Secretary to implement risk sharing with State and local housing finance agencies (HFAs). Under this...

  10. 78 FR 69077 - Notice of 30-Day Public Review Period and Availability of Final Environmental Assessment and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ... of No Significant Impact (FONSI) for the Department of Navy's (DoN) transfer of excess property at... VA's implementation and monitoring of the mitigation measures identified in the FONSI, would not have... infrastructure at the former NAS Alameda. The FONSI is available for public review for 30 days before...

  11. 78 FR 55325 - 30-Day Notice of Proposed Information Collection: U.S. Passport Renewal Application for Eligible...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... and/or card format) in the exercise of authorities granted to the Secretary of State in 22 United... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day.... SUMMARY: The Department of State has submitted the information collection described below to......

  12. 78 FR 40313 - 30-Day Notice of Proposed Information Collection: Monthly Report of Excess Income and Annual...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Monthly Report of Excess Income and Annual Report of Uses of Excess Income AGENCY: Office of the Chief Information Officer, HUD. ACTION... Information Collection: Monthly Report of Excess Income and Annual Report of Uses of Excess Income....

  13. 78 FR 59047 - 30-Day Notice of Proposed Information Collection: Semi-Annual Labor Standards Enforcement Report...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: Semi-Annual Labor Standards...: Colette Pollard, Reports Management Officer, QDAM, Department of Housing and Urban Development, 451...

  14. 78 FR 15958 - Submission for OMB Review; 30-day Comment Request: Pediatric Palliative Care Campaign Pilot Survey

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ... HUMAN SERVICES National Institutes of Health Submission for OMB Review; 30-day Comment Request: Pediatric Palliative Care Campaign Pilot Survey SUMMARY: Under the provisions of Section 3507(a)(1)(D) of... previously published in the Federal Register on December 26, 2012, page 76053 and allowed 60-days for...

  15. 78 FR 64143 - 30-Day Notice of Proposed Information Collection: FHA-Application for Insurance of Advance of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ...HUD has submitted the proposed information collection requirement described below to the Office of Management and Budget (OMB) for review, in accordance with the Paperwork Reduction Act. The purpose of this notice is to allow for an additional 30 days of public...

  16. 78 FR 55083 - Submission for OMB Review; 30-day Comment Request; Genomics and Society Public Surveys in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-09

    ... and Society Public Surveys in Conjunction With Smithsonian Museum of Natural History Genome Exhibit... an additional 30 days for public comment. The National Human Genome Research Institute (NHGRI...: Genomics and Society Public Surveys in Conjunction with National Museum of Natural History Genome...

  17. 77 FR 71668 - 30-Day Notice of Proposed Information Collection: Choice of Address and Agent for Immigrant Visa...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day Notice of Proposed Information Collection: Choice of Address and Agent for Immigrant Visa Applicants...: Title of Information Collection: Choice of Address and Agent for Immigrant Visa Applicants. OMB...

  18. 78 FR 15799 - 30-Day Notice of Proposed Information Collection: Statement Regarding a Lost or Stolen U.S...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day Notice of Proposed Information Collection: Statement Regarding a Lost or Stolen U.S. Passport Book and/or... INFORMATION: Title of Information Collection: Statement Regarding a Lost or Stolen U.S. Passport Book...

  19. 78 FR 42795 - Submission for OMB review; 30-Day Comment Request: Evaluation of the Brain Disorders in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-17

    ...: Evaluation of the Brain Disorders in the Developing World Program of the John E. Fogarty International Center... additional 30 days for public comment. The John E. Fogarty International Center (FIC), National Institutes of.... Rachel Sturke, Evaluation Officer, Division of Policy, Planning and Evaluation, FIC, NIH, Building...

  20. 77 FR 47690 - 30-Day Notice of Proposed Information Collection: Civilian Response Corps Database In-Processing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... following information collection request to the Office of Management and Budget (OMB) for approval in... Currently Approved Collection. Originating Office: Bureau of Conflict and Stabilization Operations (CSO... benefits. DATES: Submit comments to the Office of Management and Budget (OMB) for up to 30 days from...

  1. 77 FR 20687 - 30-Day Notice of Proposed Information Collection: Form DS-3097, Exchange Visitor Program Annual...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-05

    ... Visitor Information System (SEVIS) and then printed and signed by a sponsor official, and sent to the... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day Notice of Proposed Information Collection: Form DS-3097, Exchange Visitor Program Annual Report,...

  2. 31 CFR 560.515 - 30-day delayed effective date for pre-May 7, 1995 trade contracts involving Iran.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-May 7, 1995 trade contracts involving Iran. 560.515 Section 560.515 Money and Finance: Treasury....515 30-day delayed effective date for pre-May 7, 1995 trade contracts involving Iran. (a) All... involving Iran (a pre-existing trade contract), including the exportation of goods, services...

  3. 31 CFR 560.515 - 30-day delayed effective date for pre-May 7, 1995 trade contracts involving Iran.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-May 7, 1995 trade contracts involving Iran. 560.515 Section 560.515 Money and Finance: Treasury....515 30-day delayed effective date for pre-May 7, 1995 trade contracts involving Iran. (a) All... involving Iran (a pre-existing trade contract), including the exportation of goods, services...

  4. 78 FR 67385 - 30-Day Notice of Proposed Information Collection: FHA PowerSaver Pilot Program (Title I Property...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-12

    ... URBAN DEVELOPMENT 30-Day Notice of Proposed Information Collection: FHA PowerSaver Pilot Program (Title I Property Improvement and Title II--203(k) Rehabilitation Mortgage Insurance) AGENCY: Office of the... Collection Title of Information Collection: FHA PowerSaver Pilot Program (Title I Property Improvement...

  5. 78 FR 31999 - 30-Day Notice of Proposed Information Collection: Young Turkey/Young America Evaluation (YTYA...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-28

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE 30-Day Notice of Proposed Information Collection: Young Turkey/ Young America Evaluation (YTYA) Survey ACTION... Collection: Young Turkey/Young America Evaluation (YTYA) Survey. OMB Control Number: None. Type of...

  6. 77 FR 10530 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    .... Proposed Project: Generic Clearance for Communications Testing for Comprehensive Communication Campaign for... the campaign and be used to inform campaign strategies, messages, materials and Web sites. Due to...

  7. 76 FR 30363 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-25

    ... a onetime pilot test of a post- only survey tool to be added to the BodyWorks toolkit/resources; and... components as well as similar tests of the Spanish BodyWorks program. ] Estimated Annualized Burden Tables.... English & 100 1 10/60 17 Spanish Participant Exit Survey-- Post Only Pilot Study. English and 408 1...

  8. 77 FR 2297 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... students will take a pre-test quiz when they fill out the demographics form. Once the treatment is completed, all students will be asked to take a post-test quiz and answer a post-viewing questionnaire to... research integrity? To answer the first question, a pretest-posttest control group experimental design...

  9. Tests Of Shear-Flow Model For Acoustic Impedance

    NASA Technical Reports Server (NTRS)

    Parrot, Tony L.; Watson, Willie R.; Jones, Michael G.

    1992-01-01

    Tests described in report conducted to validate two-dimensional shear-flow analytical model for determination of acoustic impedance of acoustic liner in grazing-incidence, grazing-flow environment by use of infinite-waveguide method. Tests successful for both upstream and downstream propagations. Work has potential for utility in testing of engine ducts in commercial aircraft.

  10. Analysis of Flow Angularity Repeatability Tests in the NTF

    NASA Technical Reports Server (NTRS)

    Hemsch, Michael J.

    2006-01-01

    An extensive data base of flow angularity repeatability measurements from four NTF check standard model tests is analyzed for statistical consistency and to characterize the results for prediction of angle-of-attack uncertainty for customer tests. A procedure for quality assurance for flow angularity measurements during customer tests is also presented. The efficacy of the procedure is tested using results from a customer test.

  11. 76 FR 28986 - Agency Information Collection Request. 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-19

    ... clearance for collecting information through a variety of research methods for developing and testing... communication research set forth by other DHHS agencies such as the National Cancer Institute. ONC must also... Anticipated Data Collection Methods Number of Frequency of Hours per respondents response response Total...

  12. 77 FR 12305 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... pregnancy prevention evaluation efforts as part of the Teen Pregnancy Prevention Initiative. OAH is working... effective ways to reduce teen pregnancy. The evaluation will document and test a range of pregnancy... the general public, to policy-makers, and to organizations interested in teen pregnancy...

  13. 76 FR 60840 - Agency Information Collection Request; 30-Day Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-30

    ... evaluation efforts as part of the Teen Pregnancy Prevention Initiative. OAH is working collaboratively with... evidence on effective ways to reduce teen pregnancy. The evaluation will document and test a range of... interest to the general public, to policy- makers, and to organizations interested in teen...

  14. 30 Days Wild: Development and Evaluation of a Large-Scale Nature Engagement Campaign to Improve Well-Being

    PubMed Central

    Richardson, Miles; Cormack, Adam; McRobert, Lucy; Underhill, Ralph

    2016-01-01

    There is a need to increase people’s engagement with and connection to nature, both for human well-being and the conservation of nature itself. In order to suggest ways for people to engage with nature and create a wider social context to normalise nature engagement, The Wildlife Trusts developed a mass engagement campaign, 30 Days Wild. The campaign asked people to engage with nature every day for a month. 12,400 people signed up for 30 Days Wild via an online sign-up with an estimated 18,500 taking part overall, resulting in an estimated 300,000 engagements with nature by participants. Samples of those taking part were found to have sustained increases in happiness, health, connection to nature and pro-nature behaviours. With the improvement in health being predicted by the improvement in happiness, this relationship was mediated by the change in connection to nature. PMID:26890891

  15. African Easterly Waves in 30-day High-Resolution Global Simulations: A Case Study During the 2006 NAMMA Period

    NASA Technical Reports Server (NTRS)

    Shen, Bo-Wen; Tao, Wei-Kuo; Wu, Man-Li C.

    2010-01-01

    In this study, extended -range (30 -day) high-resolution simulations with the NASA global mesoscale model are conducted to simulate the initiation and propagation of six consecutive African easterly waves (AEWs) from late August to September 2006 and their association with hurricane formation. It is shown that the statistical characteristics of individual AEWs are realistically simulated with larger errors in the 5th and 6th AEWs. Remarkable simulations of a mean African easterly jet (AEJ) are also obtained. Nine additional 30 -day experiments suggest that although land surface processes might contribute to the predictability of the AEJ and AEWs, the initiation and detailed evolution of AEWs still depend on the accurate representation of dynamic and land surface initial conditions and their time -varying nonlinear interactions. Of interest is the potential to extend the lead time for predicting hurricane formation (e.g., a lead time of up to 22 days) as the 4th AEW is realistically simulated.

  16. 30 Days Wild: Development and Evaluation of a Large-Scale Nature Engagement Campaign to Improve Well-Being.

    PubMed

    Richardson, Miles; Cormack, Adam; McRobert, Lucy; Underhill, Ralph

    2016-01-01

    There is a need to increase people's engagement with and connection to nature, both for human well-being and the conservation of nature itself. In order to suggest ways for people to engage with nature and create a wider social context to normalise nature engagement, The Wildlife Trusts developed a mass engagement campaign, 30 Days Wild. The campaign asked people to engage with nature every day for a month. 12,400 people signed up for 30 Days Wild via an online sign-up with an estimated 18,500 taking part overall, resulting in an estimated 300,000 engagements with nature by participants. Samples of those taking part were found to have sustained increases in happiness, health, connection to nature and pro-nature behaviours. With the improvement in health being predicted by the improvement in happiness, this relationship was mediated by the change in connection to nature. PMID:26890891

  17. 30 Days Wild: Development and Evaluation of a Large-Scale Nature Engagement Campaign to Improve Well-Being.

    PubMed

    Richardson, Miles; Cormack, Adam; McRobert, Lucy; Underhill, Ralph

    2016-01-01

    There is a need to increase people's engagement with and connection to nature, both for human well-being and the conservation of nature itself. In order to suggest ways for people to engage with nature and create a wider social context to normalise nature engagement, The Wildlife Trusts developed a mass engagement campaign, 30 Days Wild. The campaign asked people to engage with nature every day for a month. 12,400 people signed up for 30 Days Wild via an online sign-up with an estimated 18,500 taking part overall, resulting in an estimated 300,000 engagements with nature by participants. Samples of those taking part were found to have sustained increases in happiness, health, connection to nature and pro-nature behaviours. With the improvement in health being predicted by the improvement in happiness, this relationship was mediated by the change in connection to nature.

  18. Evaluation of a Pharmacist-Specific Intervention on 30-Day Readmission Rates for High-Risk Patients with Pneumonia

    PubMed Central

    Carroll, Douglas N.; Pinner, Nathan A.

    2015-01-01

    Background: Pharmacist interventions have been shown to have an impact on reducing readmission rates, however further research is necessary to target resources to high-risk populations and determine the most effective bundle of interventions. Objective: To evaluate the effect of a pharmacist-bundled intervention on 30-day readmission rates for high-risk patients with pneumonia. Methods: A pilot study with a historical control conducted at a community, teaching-affiliated medical center. Up to 65 selected subjects were included if they had pneumonia and any of the following high-risk criteria: admission within 6 months, at least 5 scheduled home medications, chronic obstructive pulmonary disease (COPD), or heart failure. A retrospective chart review was conducted to compile the historical control group that received usual care between June and November 2013. Patients admitted from December 2013 through March 2014 were reviewed to receive a bundled intervention. The primary outcome was 30-day readmission rates. Risk factors and reasons for readmission, pharmacist clinical interventions, and the time interval between discharge and readmission were also evaluated. Results: A trend toward a reduced 30-day readmission rate was observed in the intervention group (n = 43) compared to those who received usual care (n = 65) (27.9% vs 40.0%; relative risk [RR], 0.6977; 95% CI, 0.3965–1.2278; P = .2119). The most commonly identified high-risk inclusion criteria were having at least 5 scheduled home medications and COPD. The time interval between discharge and readmission did not considerably differ between groups (10.8 vs 10.6 days). Conclusions: The pharmacist-bundled intervention was associated with a reduced 30-day readmission rate for high-risk patients with pneumonia. PMID:26823619

  19. Using multiple household food inventories to measure food availability in the home over 30 days: a pilot study

    PubMed Central

    2010-01-01

    Background The consumption of foods, especially by children, may be determined by the types of foods that are available in the home. Because most studies use a single point of data collection to determine the types of foods in the home, which can miss the change in availability when resources are not available, the primary objective of this study was to determine the extent to which the weekly availability of household food items changed over one month by 1) developing the methodology for the direct observation of the presence and amount of food items in the home; 2) conducting five in-home household food inventories over a thirty-day period in a small convenience sample; and 3) determining the frequency that food items were present in the participating households. Methods After the development and pre-testing of the 251-item home observation guide that used direct observation to determine the presence and amount of food items in the home (refrigerator, freezer, pantry, elsewhere), two trained researchers recruited a convenience sample of 9 households (44.4% minority); administered a baseline questionnaire (personal info, shopping habits, food resources, and food security); and conducted 5 in-home assessments (7-day interval) over a 30-day period. Each in-home assessment included food-related activities since the last assessment, and an observational survey of types and amounts of foods present. Results Complete data were collected from all 9 women (32.8 y ± 6.0; 3 married; 4 ± 1.6 adults/children in household; 4 received food assistance; and 6 had very low food security) and their households. Weekly grocery purchases (place, amount, and purpose) varied from once (n = 1) to every week (n = 5); 4 used fast food 2-3 times/wk for 4 weeks. The weekly presence and amounts of fresh and processed fruits and vegetables and dairy varied. Conclusions The feasibility of conducting multiple in-home assessments was confirmed with 100% retention of participants through 5 in

  20. Prediction of Hospital Acute Myocardial Infarction and Heart Failure 30-Day Mortality Rates Using Publicly Reported Performance Measures

    PubMed Central

    Aaronson, David S.; Bardach, Naomi S.; Lin, Grace A.; Chattopadhyay, Arpita; Goldman, L. Elizabeth; Dudley, R. Adams

    2014-01-01

    Objective To identify an approach to summarizing publicly reported hospital performance data for acute myocardial infarction (AMI) or heart failure (HF) that best predicts current year hospital mortality rates. Setting A total of 1,868 U.S. hospitals reporting process and outcome measures for AMI and HF to the Centers for Medicare and Medicaid Services (CMS) from July 2005 to June 2006 (Year 0) and July 2006 to June 2007 (Year 1). Design Observational cohort study measuring the percentage variation in Year 1 hospital 30-day risk-adjusted mortality rate explained by denominator-based weighted composite scores summarizing hospital Year 0 performance. Data Collection Data were prospectively collected from hospitalcompare.gov. Results Percentage variation in Year 1 mortality was best explained by mortality rate alone in Year 0 over other composites including process performance. If only Year 0 mortality rates were reported, and consumers using hospitals in the highest decile of mortality instead chose hospitals in the lowest decile of mortality rate, the number of deaths at 30 days that potentially could have been avoided was 1.31 per 100 patients for AMI and 2.12 for HF (p < .001). Conclusion Public reports focused on 30-day risk-adjusted mortality rate may more directly address policymakers’ goals of facilitating consumer identification of hospitals with better outcomes. PMID:22093186

  1. The Readmission Risk Flag: Using the Electronic Health Record to Automatically Identify Patients at Risk for 30-day Readmission

    PubMed Central

    Baillie, Charles A.; VanZandbergen, Christine; Tait, Gordon; Hanish, Asaf; Leas, Brian; French, Benjamin; Hanson, C. William; Behta, Maryam; Umscheid, Craig A.

    2015-01-01

    Background Identification of patients at high risk for readmission is a crucial step toward improving care and reducing readmissions. The adoption of electronic health records (EHR) may prove important to strategies designed to risk stratify patients and introduce targeted interventions. Objective To develop and implement an automated prediction model integrated into our health system’s EHR that identifies on admission patients at high risk for readmission within 30 days of discharge. Design Retrospective and prospective cohort. Setting Healthcare system consisting of three hospitals. Patients All adult patients admitted from August 2009 to September 2012. Interventions An automated readmission risk flag integrated into the EHR. Measures Thirty-day all-cause and 7-day unplanned healthcare system readmissions. Results Using retrospective data, a single risk factor, ≥2 inpatient admissions in the past 12 months, was found to have the best balance of sensitivity (40%), positive predictive value (31%), and proportion of patients flagged (18%), with a c-statistic of 0.62. Sensitivity (39%), positive predictive value (30%), proportion of patients flagged (18%) and c-statistic (0.61) during the 12-month period after implementation of the risk flag were similar. There was no evidence for an effect of the intervention on 30-day all-cause and 7-day unplanned readmission rates in the 12-month period after implementation. Conclusions An automated prediction model was effectively integrated into an existing EHR and identified patients on admission who were at risk for readmission within 30 days of discharge. PMID:24227707

  2. Oscillating-flow regenerator test rig

    NASA Technical Reports Server (NTRS)

    Wood, J. G.; Gedeon, D. R.

    1994-01-01

    This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

  3. Oscillating flow loss test results in Stirling engine heat exchangers

    NASA Technical Reports Server (NTRS)

    Koester, G.; Howell, S.; Wood, G.; Miller, E.; Gedeon, D.

    1990-01-01

    The results are presented for a test program designed to generate a database of oscillating flow loss information that is applicable to Stirling engine heat exchangers. The tests were performed on heater/cooler tubes of various lengths and entrance/exit configurations, on stacked and sintered screen regenerators of various wire diameters and on Brunswick and Metex random fiber regenerators. The test results were performed over a range of oscillating flow parameters consistent with Stirling engine heat exchanger experience. The tests were performed on the Sunpower oscillating flow loss rig which is based on a variable stroke and variable frequency linear drive motor. In general, the results are presented by comparing the measured oscillating flow losses to the calculated flow losses. The calculated losses are based on the cycle integration of steady flow friction factors and entrance/exit loss coefficients.

  4. Capillary flow solderability test for printed wiring boards

    SciTech Connect

    Hosking, F.M.; Yost, F.G.; Hernandez, C.L.; Sackinger, S.J.

    1994-04-01

    This report describes a new technique for evaluating capillary flow solderability on printed circuit boards. The test involves the flow of molten solder from a pad onto different-sized conductor lines. It simulates the spreading dynamics of either plated-through-hole (PTH) or surface mount technology (SMT) soldering. A standard procedure has been developed for the test. Preliminary experiments were conducted and the results demonstrate test feasibility. Test procedures and results are presented in this report.

  5. NASA Flight Tests Explore Supersonic Laminar Flow

    NASA Video Gallery

    In partnership with Aerion Corporation of Reno, Nevada, NASA's Dryden Flight Research Center’s tested supersonic airflow over a small experimental airfoil design on its F-15B Test Bed aircraft du...

  6. Assessment of the National Transonic Facility for Laminar Flow Testing

    NASA Technical Reports Server (NTRS)

    Crouch, Jeffrey D.; Sutanto, Mary I.; Witkowski, David P.; Watkins, A. Neal; Rivers, Melissa B.; Campbell, Richard L.

    2010-01-01

    A transonic wing, designed to accentuate key transition physics, is tested at cryogenic conditions at the National Transonic Facility at NASA Langley. The collaborative test between Boeing and NASA is aimed at assessing the facility for high-Reynolds number testing of configurations with significant regions of laminar flow. The test shows a unit Reynolds number upper limit of 26 M/ft for achieving natural transition. At higher Reynolds numbers turbulent wedges emanating from the leading edge bypass the natural transition process and destroy the laminar flow. At lower Reynolds numbers, the transition location is well correlated with the Tollmien-Schlichting-wave N-factor. The low-Reynolds number results suggest that the flow quality is acceptable for laminar flow testing if the loss of laminar flow due to bypass transition can be avoided.

  7. Neuropsychological changes after 30-day Ginkgo biloba administration in healthy participants.

    PubMed

    Stough, C; Clarke, J; Lloyd, J; Nathan, P J

    2001-06-01

    Ginkgo biloba extract (EGb) from the world's oldest living tree has been reputed to ameliorate cognitive decline in the elderly and slow cognitive deterioration in patients with dementia of the Alzheimer's type. EGb remains as one of the most popular plant extracts to alleviate symptoms associated with a range of cognitive disorders such as Alzheimer's disease, vascular dementia and age-related amnesic conditions. EGb is known to contain a range of chemically active components that have antagonistic effects on platelet-activating factor, free-radical scavenging activity and direct effects on the cholinergic neurotransmitter system. Recently there has been much speculation, that EGb may act as a 'smart drug' or nootropic agent in the healthy young to improve intelligence. We conducted a 30-d randomized, double-blind, placebo-controlled clinical trial in which 61 participants were administered a battery of validated neuropsychological tests before and after treatment. Statistical analysis indicated significant improvements in speed of information processing working memory and executive processing attributable to the EGb.

  8. Results of no-flow rotary drill bit comparison testing

    SciTech Connect

    WITWER, K.S.

    1998-11-30

    This document describes the results of testing of a newer rotary sampling bit and sampler insert called the No-Flow System. This No-Flow System was tested side by side against the currently used rotary bit and sampler insert, called the Standard System. The two systems were tested using several ''hard to sample'' granular non-hazardous simulants to determine which could provide greater sample recovery. The No-Flow System measurably outperformed the Standard System in each of the tested simulants.

  9. Separate Flow Nozzle Test Status Meeting

    NASA Technical Reports Server (NTRS)

    Saiyed, Naseem H. (Editor)

    2000-01-01

    NASA Glenn, in partnership with US industry, completed an exhaustive experimental study on jet noise reduction from separate flow nozzle exhaust systems. The study developed a data base on various bypass ratio nozzles, screened quietest configurations and acquired pertinent data for predicting the plume behavior and ultimately its corresponding jet noise. Several exhaust system configurations provided over 2.5 EPNdB jet noise reduction at take-off power. These data were disseminated to US aerospace industry in a conference hosted by NASA GRC whose proceedings are shown in this report.

  10. Impact of preoperative serum albumin on 30-day mortality following surgery for colorectal cancer: a population-based cohort study

    PubMed Central

    Montomoli, Jonathan; Erichsen, Rune; Antonsen, Sussie; Nilsson, Tove; Sørensen, Henrik Toft

    2015-01-01

    Objective Surgery is the only potentially curable treatment for colorectal cancer (CRC), but it is hampered by high mortality. Human serum albumin (HSA) below 35 g/L is associated with poor overall prognosis in patients with CRC, but evidence regarding the impact on postoperative mortality is sparse. Methods We performed a population-based cohort study including patients undergoing CRC surgery in North and Central Denmark (1997–2011). We categorised patients according to HSA concentration measured 1–30 days prior to surgery date. We used the Kaplan-Meier method to compute 30-day mortality and Cox regression model to compute HRs as measures of the relative risk of death, controlling for potential confounders. We further stratified patients by preoperative conditions, including cancer stage, comorbidity level, and C reactive protein concentration. Results Of the 9339 patients undergoing first-time CRC surgery with preoperative HSA measurement, 26.4% (n=2464) had HSA below 35 g/L. 30-day mortality increased from 4.9% among patients with HSA 36–40 g/L to 26.9% among patients with HSA equal to or below 25 g/L, compared with 2.0% among patients with HSA above 40 g/L. The corresponding adjusted HRs increased from 1.75 (95% CI 1.25 to 2.45) among patients with HSA 36–40 g/L to 7.59 (95% CI 4.95 to 11.64) among patients with HSA equal to or below 25 g/L, compared with patients with HSA above 40 g/L. The negative impact associated with a decrement of HSA was found in all subgroups. Conclusions A decrement in preoperative HSA concentration was associated with substantial concentration-dependent increased 30-day mortality following CRC surgery. PMID:26462287

  11. Hospital Nursing and 30-Day Readmissions among Medicare Patients with Heart Failure, Acute Myocardial Infarction, and Pneumonia

    PubMed Central

    McHugh, Matthew D.; Ma, Chenjuan

    2013-01-01

    Background Provisions of the Affordable Care Act that increase hospitals’ financial accountability for preventable readmissions have heightened interest in identifying system-level interventions to reduce readmissions. Objectives To determine the relationship between hospital nursing; i.e. nurse work environment, nurse staffing levels, and nurse education, and 30-day readmissions among Medicare patients with heart failure, acute myocardial infarction, and pneumonia. Method and Design Analysis of linked data from California, New Jersey, and Pennsylvania that included information on the organization of hospital nursing (i.e., work environment, patient-to-nurse ratios, and proportion of nurses holding a BSN degree) from a survey of nurses, as well as patient discharge data, and American Hospital Association Annual Survey data. Robust logistic regression was used to estimate the relationship between nursing factors and 30-day readmission. Results Nearly one-quarter of heart failure index admissions (23.3% [n=39,954]); 19.1% (n=12,131) of myocardial infarction admissions; and 17.8% (n=25,169) of pneumonia admissions were readmitted within 30-days. Each additional patient per nurse in the average nurse’s workload was associated with a 7% higher odds of readmission for heart failure (OR=1.07, [1.05–1.09]), 6% for pneumonia patients (OR=1.06, [1.03–1.09]), and 9% for myocardial infarction patients (OR=1.09, [1.05–1.13]). Care in a hospital with a good versus poor work environment was associated with odds of readmission that were 7% lower for heart failure (OR = 0.93, [0.89–0.97]); 6% lower for myocardial infarction (OR = 0.94, [0.88–0.98]); and 10% lower for pneumonia (OR = 0.90, [0.85–0.96]) patients. Conclusions Improving nurses’ work environments and staffing may be effective interventions for preventing readmissions. PMID:23151591

  12. A space maintainability experiment aboard the Ben Franklin submersible during the 30-day Gulf Stream drift mission.

    NASA Technical Reports Server (NTRS)

    Kappler, J. R.; May, C. B.

    1972-01-01

    In the summer of 1969, a deep submersible drifted for 30 days below the surface of the Gulf Stream, while operated by a six man crew. The main purpose of the mission was oceanographic research. The crew's activities and completely self-contained environment resembled those of a space station such as Skylab. Because of these similarities aspects of onboard vehicle maintenance during the actual conduct of a scientific mission were investigated. The maintainability study was accomplished in six distinct phases. Two useful plots of manpower distribution were developed. A maintenance action summary is presented in a table.

  13. Test flow disturbances in an expansion tube

    NASA Technical Reports Server (NTRS)

    Paull, A.; Stalker, R. J.

    1992-01-01

    The operation of an expansion tube is investigated theoretically with emphasis on the factors that have limited the utility of the expansion tube in the past. It is shown why the window of steady test conditions is narrow and how this window can be expanded so that these facilities can be used in a variety of hypersonic research. The theoretical predictions are supported by centerline Pitot pressure measurements using air as the test gas.

  14. Flow Simulation of Solid Rocket Motors. 1; Injection Induced Water-Flow Tests from Porous Media

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Yeh, Y. P.; Smith, A. W.; Heaman, J. P.

    1999-01-01

    Prior to selecting a proper porous material for use in simulating the internal port flow of a solid rocket motor (SRM), in cold-flow testing, the flow emerging from porous materials is experimentally investigated. The injection-flow emerging from a porous matrix always exhibits a lumpy velocity profile that is spatially stable and affects the development of the longitudinal port flow. This flow instability, termed pseudoturbulence, is an inherent signature of the porous matrix and is found to generally increase with the wall porosity and with the injection flow rate. Visualization studies further show that the flow from porous walls made from shaving-type material (sintered stainless-steel) exhibits strong recirculation zones that are conspicuously absent in walls made from nodular or spherical material (sintered bronze). Detailed flow visualization observations and hot-film measurements are reported from tests of injection-flow and a coupled cross-flow from different porous wall materials. Based on the experimental data, discussion is provided on the choice of suitable material for SRM model testing while addressing the consequences and shortcomings from such a test.

  15. Flight tests of a supersonic natural laminar flow airfoil

    NASA Astrophysics Data System (ADS)

    Frederick, M. A.; Banks, D. W.; Garzon, G. A.; Matisheck, J. R.

    2015-06-01

    A flight test campaign of a supersonic natural laminar flow airfoil has been recently completed. The test surface was an 80 inch (203 cm) chord and 40 inch (102 cm) span article mounted on the centerline store location of an F-15B airplane. The test article was designed with a leading edge sweep of effectively 0° to minimize boundary layer crossflow. The test article surface was coated with an insulating material to avoid significant heat transfer to and from the test article structure to maintain a quasi-adiabatic wall. An aircraft-mounted infrared camera system was used to determine boundary layer transition and the extent of laminar flow. The tests were flown up to Mach 2.0 and chord Reynolds numbers in excess of 30 million. The objectives of the tests were to determine the extent of laminar flow at high Reynolds numbers and to determine the sensitivity of the flow to disturbances. Both discrete (trip dots) and 2D disturbances (forward-facing steps) were tested. A series of oblique shocks, of yet unknown origin, appeared on the surface, which generated sufficient crossflow to affect transition. Despite the unwanted crossflow, the airfoil performed well. The results indicate that the sensitivity of the flow to the disturbances, which can translate into manufacturing tolerances, was similar to that of subsonic natural laminar flow wings.

  16. Flight Tests of a Supersonic Natural Laminar Flow Airfoil

    NASA Technical Reports Server (NTRS)

    Frederick, Michael A.; Banks, Daniel W.; Garzon, G. A.; Matisheck, J. R.

    2015-01-01

    A flight-test campaign of a supersonic natural laminar flow airfoil has been recently completed. The test surface was an 80-inch (203 cm) chord and 40-inch (102 cm) span article mounted on the centerline store location of an F-15B airplane (McDonnell Douglas Corporation, now The Boeing Company, Chicago, Illinois). The test article was designed with a leading edge sweep of effectively 0 deg to minimize boundary layer crossflow. The test article surface was coated with an insulating material to avoid significant heat transfer to and from the test article structure to maintain a quasi-adiabatic wall. An aircraft-mounted infrared camera system was used to determine boundary layer transition and the extent of laminar flow. The tests were flown up to Mach 2.0 and chord Reynolds numbers in excess of 30 million. The objectives of the tests were to determine the extent of laminar flow at high Reynolds numbers and to determine the sensitivity of the flow to disturbances. Both discrete (trip dots) and 2-D disturbances (forward-facing steps) were tested. A series of oblique shocks, of yet unknown origin, appeared on the surface, which generated sufficient crossflow to affect transition. Despite the unwanted crossflow, the airfoil performed well. The results indicate the sensitivity of the flow to the disturbances, which can translate into manufacturing tolerances, were similar to that of subsonic natural laminar flow wings.

  17. Readmission for Acute Exacerbation within 30 Days of Discharge Is Associated with a Subsequent Progressive Increase in Mortality Risk in COPD Patients: A Long-Term Observational Study

    PubMed Central

    Guerrero, Mónica; Crisafulli, Ernesto; Liapikou, Adamantia; Huerta, Arturo; Gabarrús, Albert; Chetta, Alfredo; Soler, Nestor; Torres, Antoni

    2016-01-01

    Background and Objective Twenty per cent of chronic obstructive pulmonary disease (COPD) patients are readmitted for acute exacerbation (AECOPD) within 30 days of discharge. The prognostic significance of early readmission is not fully understood. The objective of our study was to estimate the mortality risk associated with readmission for acute exacerbation within 30 days of discharge in COPD patients. Methods The cohort (n = 378) was divided into patients readmitted (n = 68) and not readmitted (n = 310) within 30 days of discharge. Clinical, laboratory, microbiological, and severity data were evaluated at admission and during hospital stay, and mortality data were recorded at four time points during follow-up: 30 days, 6 months, 1 year and 3 years. Results Patients readmitted within 30 days had poorer lung function, worse dyspnea perception and higher clinical severity. Two or more prior AECOPD (HR, 2.47; 95% CI, 1.51–4.05) was the only variable independently associated with 30-day readmission. The mortality risk during the follow-up period showed a progressive increase in patients readmitted within 30 days in comparison to patients not readmitted; moreover, 30-day readmission was an independent risk factor for mortality at 1 year (HR, 2.48; 95% CI, 1.10–5.59). In patients readmitted within 30 days, the estimated absolute increase in the mortality risk was 4% at 30 days (number needed to harm NNH, 25), 17% at 6-months (NNH, 6), 19% at 1-year (NNH, 6) and 24% at 3 years (NNH, 5). Conclusion In conclusion a readmission for AECOPD within 30 days is associated with a progressive increased long-term risk of death. PMID:26943928

  18. Flow tests of the Willis Hulin well

    SciTech Connect

    Randolph, P.L.; Hayden, C.G.; Rogers, L.A.

    1992-02-01

    The Hulin well was tested between 20,100 and 20,700 feet down in layers of brine-saturated clean sand with occasional intervening layers of shale. The characteristics of the brine and gas were determined in this interval and an initial determination of the reservoir properties were made.

  19. 46 CFR 162.018-7 - Flow rating tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-7 Flow rating tests. (a) Flow rating of valves shall be conducted in accordance with UG-131 of section VIII of... the Commanding Officer, USCG Marine Safety Center. (b)...

  20. 46 CFR 162.018-7 - Flow rating tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-7 Flow rating tests. (a) Flow rating of valves shall be conducted in accordance with UG-131 of section VIII of... the Commanding Officer, USCG Marine Safety Center. (b)...

  1. 46 CFR 162.018-7 - Flow rating tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Safety Relief Valves, Liquefied Compressed Gas § 162.018-7 Flow rating tests. (a) Flow rating of valves shall be conducted in accordance with UG-131 of section VIII of... the Commanding Officer, USCG Marine Safety Center. (b)...

  2. Ambient Test Rig (ATR) flow studies: A laminar flow, reduced entrainment electrostatic precipitator

    SciTech Connect

    Not Available

    1988-10-01

    Results of flow testing on a Reduced Entrainment Precipitator Ambient Test Rig are presented. The Reduced Entrainment Precipitator concept involves drawing a portion of the main precipitator flow through hollow, porous collecting plates. The purposes of flow through porous collecting plates ( side flow'') are to provide a dust layer clamping force, and to reduce turbulence with the precipitator. Achievement of these goals should reduce re-entrainment, and result in increased precipitator efficiency. The increased efficiency should be especially evident at higher precipitator main flow velocities. Flow tests conducted included pilot tube velocity traverses, smoke (turbulence) visualization, and measurements of turbulence and velocity with a (fast-response) hot-wire anemometer. 12 refs., 13 figs.

  3. Flight Tests of a Supersonic Natural Laminar Flow Airfoil

    NASA Technical Reports Server (NTRS)

    Frederick, M. A.; Banks, D. W.; Garzon, G. A.; Matisheck, J. R.

    2014-01-01

    A flight test campaign of a supersonic natural laminar flow airfoil has been recently completed. The test surface was an 80-inch (203 cm) chord and 40-inch (102 cm) span article mounted on the centerline store location of an F-15B airplane. The wing was designed with a leading edge sweep of effectively 0 deg to minimize boundary layer crossflow. The test article surface was coated with an insulating material to avoid significant heat transfer to and from the test article structure to maintain a quasi-adiabatic wall. An aircraft-mounted infrared camera system was used to determine boundary layer transition and the extent of laminar flow. The tests were flown up to Mach 2.0 and chord Reynolds numbers in excess of 30 million. The objectives of the tests were to determine the extent of laminar flow at high Reynolds numbers and to determine the sensitivity of the flow to disturbances. Both discrete (trip dots) and 2-D disturbances (forward-facing steps) were tested. A series of oblique shocks, of yet unknown origin, appeared on the surface, which generated sufficient crossflow to affect transition. Despite the unwanted crossflow, the airfoil performed well. The results indicate the sensitivity of the flow to the disturbances, which can translate into manufacturing tolerances, were similar to that of subsonic natural laminar flow wings.

  4. Turbine Air-Flow Test Rig CFD Results for Test Matrix

    NASA Technical Reports Server (NTRS)

    Wilson, Josh

    2003-01-01

    This paper presents the Turbine Air-Flow Test (TAFT) rig computational fluid dynamics (CFD) results for test matrix. The topics include: 1) TAFT Background; 2) Design Point CFD; 3) TAFT Test Plan and Test Matrix; and 4) CFD of Test Points. This paper is in viewgraph form.

  5. [Effect of 30-day space flight and subsequent readaptation on the signaling processes in m. longissimus dorsi of mice].

    PubMed

    Mirzoev, T M; Vil'chinskaia, N A; Lomonosova, Iu N; Nemirovskaia, T L; Shenkman, B S

    2014-01-01

    Some steps of anabolic and catabolic signaling pathways were investigated in postural/tonic m. longissimus dorsi of mice following the 30-day orbital flight of biosatellite "Bion-M1" and 8-day recovery. Western blotting was used for determining insulin receptor substrate 1 (IRS-1) and AMR-activated protein kinase (AMPK) involved in reciprocal regulation of anabolic and catabolic pathways, as well as E3-ligase MURF-1, and elongation factor eEF2. Functioning of the IGF-1-dependent IRS-1 signaling pathway was activated in the recovery period only. Though the content of ubiquitinligase MURF-1 showed an increase after flight, on completion of the recovery period it did not exceed the pre-flight level unambiguously.

  6. Income inequality and 30 day outcomes after acute myocardial infarction, heart failure, and pneumonia: retrospective cohort study

    PubMed Central

    Lagu, Tara; Rothberg, Michael B; Avrunin, Jill; Pekow, Penelope S; Wang, Yongfei; Krumholz, Harlan M

    2013-01-01

    Objectives To examine the association between income inequality and the risk of mortality and readmission within 30 days of hospitalization. Design Retrospective cohort study of Medicare beneficiaries in the United States. Hierarchical, logistic regression models were developed to estimate the association between income inequality (measured at the US state level) and a patient’s risk of mortality and readmission, while sequentially controlling for patient, hospital, other state, and patient socioeconomic characteristics. We considered a 0.05 unit increase in the Gini coefficient as a measure of income inequality. Setting US acute care hospitals. Participants Patients aged 65 years and older, and hospitalized in 2006-08 with a principal diagnosis of acute myocardial infarction, heart failure, or pneumonia. Main outcome measures Risk of death within 30 days of admission or rehospitalization for any cause within 30 days of discharge. The potential number of excess deaths and readmissions associated with higher levels of inequality in US states in the three highest quarters of income inequality were compared with corresponding data in US states in the lowest quarter. Results Mortality analyses included 555 962 admissions (4348 hospitals) for acute myocardial infarction, 1 092 285 (4484) for heart failure, and 1 146 414 (4520); readmission analyses included 553 037 (4262), 1 345 909 (4494), and 1 345 909 (4524) admissions, respectively. In 2006-08, income inequality in US states (as measured by the average Gini coefficient over three years) varied from 0.41 in Utah to 0.50 in New York. Multilevel models showed no significant association between income inequality and mortality within 30 days of admission for patients with acute myocardial infarction, heart failure, or pneumonia. By contrast, income inequality was associated with rehospitalization (acute myocardial infarction, risk ratio 1.09 (95% confidence interval 1.03 to 1.15), heart failure 1

  7. Effect of a 30-day isolation stress on calcium, phosphorus and other excretory products in an unrestrained chimpanzee.

    NASA Technical Reports Server (NTRS)

    Sabbot, I. M.; Mcnew, J. J.; Hoshizaki, T.; Sedgwick, C. J.; Adey, W. R.

    1972-01-01

    An unrestrained chimpanzee was studied in an isolation chamber and in his home cage environment. The study consisted of 49 urine collection days (14 days pre-, 5 days post- and 30 days of isolation), and then of 10 days in the home cage. Dietary intake, urine and fecal data were obtained. The effect of isolation on various excretory parameters was studied. Urine samples were analyzed for volume, osmolarity, creatinine, creatine, urea-N, 17-hydroxy corticosteroids, VMA, calcium and inorganic phosphorus. One way analyses of variance performed on the urinary excretion parameters showed all except creatinine excretion to vary significantly during periods of the study. The changes observed in calcium and phosphorus were highly significant. The data suggests that the calcium to phosphorus excretion ratio might serve as a physiological stress indicator of Selye's adaptation syndrome (period of resistance).

  8. Can the American College of Surgeons Risk Calculator Predict 30-Day Complications After Knee and Hip Arthroplasty?

    PubMed

    Edelstein, Adam I; Kwasny, Mary J; Suleiman, Linda I; Khakhkhar, Rishi H; Moore, Michael A; Beal, Matthew D; Manning, David W

    2015-09-01

    Accurate risk stratification of patients undergoing total hip (THA) and knee (TKA) arthroplasty is essential in the highly scrutinized world of pay-for-performance, value-driven healthcare. We assessed the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) surgical risk calculator's ability to predict 30-day complications using 1066 publicly-reported Medicare patients undergoing primary THA or TKA. Risk estimates were significantly associated with complications in the categories of any complication (P = .005), cardiac complication (P < .001), pneumonia (P < .001) and discharge to skilled nursing facility (P < .001). However, predictability of complication occurrence was poor for all complications assessed. To facilitate the equitable provision and reimbursement of patient care, further research is needed to develop accurate risk stratification tools in TKA and THA surgery. PMID:26165953

  9. Alterations of the in vivo torque-velocity relationship of human skeletal muscle following 30 days exposure to simulated microgravity

    NASA Technical Reports Server (NTRS)

    Dudley, Gary A.; Duvoisin, Marc; Convertino, Victor A.; Buchanan, Paul

    1989-01-01

    The effect of a continuous 30-d-long 6-deg headdown bedrest (BR) on the force output ability of skeletal muscles was investigated in human subjects by measuring peak angle specific torque of the knee extensor (KE) and knee flexor (KF) muscle groups of both limbs during unilateral efforts at four speeds (0.52. 1.74, 2.97, and 4.19 rad/sec) during eccentric action. It was found that, for the KE muscle group, the headdown BR resulted in decreases, by 19 percent on the average, of peak angle specific torque; on the other hand, the strength of the KF muscles was not altered significantly. A post-BR recovery for 30 days was found to restore muscle strength of the KE muscle group to about 92 percent of the pre-BR values. Changes of strength were not affected by the type of speed of muscle action.

  10. Classifying emergency 30-day readmissions in England using routine hospital data 2004–2010: what is the scope for reduction?

    PubMed Central

    Blunt, Ian; Bardsley, Martin; Grove, Amy; Clarke, Aileen

    2015-01-01

    Background Many health systems across the globe have introduced arrangements to deny payment for patients readmitted to hospital as an emergency. The purpose of this study was to develop an exploratory categorisation based on likely causes of readmission, and then to assess the prevalence of these different types. Methods Retrospective analysis of 82 million routinely collected National Health Service hospital records in England (2004–2010) was undertaken using anonymised linkage of records at person-level. Numbers of 30-day readmissions were calculated. Exploratory categorisation of readmissions was applied using simple rules relating to International Classification of Diseases (ICD) diagnostic codes for both admission and readmission. Results There were 5 804 472 emergency 30-day readmissions over a 6-year period, equivalent to 7.0% of hospital discharges. Readmissions were grouped into hierarchically exclusive categories: potentially preventable readmission (1 739 519 (30.0% of readmissions)); anticipated but unpredictable readmission (patients with chronic disease or likely to need long-term care; 1 141 987 (19.7%)); preference-related readmission (53 718 (0.9%)); artefact of data collection (16 062 (0.3%)); readmission as a result of accident, coincidence or related to a different body system (1 101 818 (19.0%)); broadly related readmission (readmission related to the same body system (1 751 368 (30.2%)). Conclusions In this exploratory categorisation, a large minority of emergency readmissions (eg, those that are potentially preventable or due to data artefacts) fell into groups potentially amenable to immediate reduction. For other categories, a hospital's ability to reduce emergency readmission is less clear. Reduction strategies and payment incentives must be carefully tailored to achieve stated aims. PMID:24668396

  11. Factors associated with moderate or severe left atrioventricular valve regurgitation within 30 days of repair of incomplete atrioventricular septal defect

    PubMed Central

    Kozak, Marcelo Felipe; Kozak, Ana Carolina Leiroz Ferreira Botelho Maisano; Marchi, Carlos Henrique De; de Godoy, Moacyr Fernandes; Croti, Ulisses Alexandre; Moscardini, Airton Camacho

    2015-01-01

    Introduction Left atrioventricular valve regurgitation is the most concerning residual lesion after surgical correction of atrioventricular septal defect. Objective To determine factors associated with moderate or greater left atrioventricular valve regurgitation within 30 days of surgical repair of incomplete atrioventricular septal defect. Methods We assessed the results of 51 consecutive patients 14 years-old and younger presenting with incomplete atrioventricular septal defect that were operated on at our practice between 2002 and 2010. The following variables were considered: age, weight, absence of Down syndrome, grade of preoperative left atrioventricular valve regurgitation, abnormalities on the left atrioventricular valve and the use of annuloplasty. The median age was 4.1 years; the median weight was 13.4 Kg; 37.2% had Down syndrome. At the time of preoperative evaluation, there were 23 cases with moderate or greater left atrioventricular valve regurgitation (45.1%). Abnormalities on the left atrioventricular valve were found in 17.6%; annuloplasty was performed in 21.6%. Results At the time of postoperative evaluation, there were 12 cases with moderate or greater left atrioventricular valve regurgitation (23.5%). The variation between pre- and postoperative grades of left atrioventricular valve regurgitation of patients with atrioventricular valve malformation did not reach significance (P=0.26), unlike patients without such abnormalities (P=0.016). During univariate analysis, only absence of Down syndrome was statistically significant (P=0.02). However, after a multivariate analysis, none of the factors reached significance. Conclusion None of the factors studied was determinant of a moderate or greater left atrioventricular valve regurgitation within the first 30 days of repair of incomplete atrioventricular septal defect in the sample. Patients without abnormalities on the left atrioventricular valve benefit more of the operation. PMID:26107451

  12. Anabolic and Catabolic Signaling Pathways in mouse Longissimus Dorsi after 30-day BION-M1 Spaceflight and Subsequent Recovery

    NASA Astrophysics Data System (ADS)

    Mirzoev, Timur; Blottner, Dieter; Shenkman, Boris; Lomonosova, Yulia; Vilchinskaya, Natalia; Nemirovskaya, Tatiana; Salanova, Michele

    The aim of the study was to analyze some of the key markers regulating anabolic and catabolic processes in mouse m. longissimus dorsi, an important back muscle system for trunk stabilization, following 30-day spaceflight and 8-day recovery period. C57/black mice were divided into 3 groups: 1) Vivarium Control (n=7), 2) Flight (n=5), 3) Recovery (n=5). The experiment was carried out in accordance with the rules of biomedical ethics certified by the Russian Academy of Sciences Committee on Bioethics. Using Western-blotting analysis we determined the content of IRS-1, p-AMPK, MURF-1 and eEF2 in m. longissimus dorsi. The content of IRS-1 in mice m. longissimus dorsi after the 30-day flight did not differ from the control group, however, in the Recovery group IRS-1 level was 80% higher (p<0.05) as compared to Control. Phospho-AMPK content remained unchanged. In the Recovery group there was an increase of eEF2 by 75% compared to the Control (p<0.05). After spaceflight MuRF-1 content was increased more than 2 times compared to the control animals. Thus, our findings showed that the work of the IRS-1 - dependent signaling pathway is only active in the recovery period. The content of the ubiquitin-ligase MURF-1 that takes parts in degrading myosin heavy chain was increased after the spaceflight, however, after 8-day recovery period MURF-1 level did not exceed the control indicating normalization of protein degradation in m. longissimus dorsi. The work was supported by the program of basic research of RAS and Federal Space Program of Russia for the period of 2006-2015.

  13. Flammable gas interlock spoolpiece flow response test plan and procedure

    SciTech Connect

    Schneider, T.C., Fluor Daniel Hanford

    1997-02-13

    The purpose of this test plan and procedure is to test the Whittaker electrochemical cell and the Sierra Monitor Corp. flammable gas monitors in a simulated field flow configuration. The sensors are used on the Rotary Mode Core Sampling (RMCS) Flammable Gas Interlock (FGI), to detect flammable gases, including hydrogen and teminate the core sampling activity at a predetermined concentration level.

  14. Analytical flow/thermal modeling of combustion gas flows in Redesigned Solid Rocket Motor test joints

    NASA Technical Reports Server (NTRS)

    Woods, G. H.; Knox, E. C.; Pond, J. E.; Bacchus, D. L.; Hengel, J. E.

    1992-01-01

    A one-dimensional analytical tool, TOPAZ (Transient One-dimensional Pipe flow AnalyZer), was used to model the flow characteristics of hot combustion gases through Redesigned Solid Rocket Motor (RSRM) joints and to compute the resultant material surface temperatures and o-ring seal erosion of the joints. The capabilities of the analytical tool were validated with test data during the Seventy Pound Charge (SPC) motor test program. The predicted RSRM joint thermal response to ignition transients was compared with test data for full-scale motor tests. The one-dimensional analyzer is found to be an effective tool for simulating combustion gas flows in RSRM joints and for predicting flow and thermal properties.

  15. ac power control in the Core Flow Test Loop

    SciTech Connect

    McDonald, D.W.

    1980-01-01

    This work represents a status report on a development effort to design an ac power controller for the Core Flow Test Loop. The Core Flow Test Loop will be an engineering test facility which will simulate the thermal environment of a gas-cooled fast-breeder reactor. The problems and limitations of using sinusoidal ac power to simulate the power generated within a nuclear reactor are addressed. The transformer-thyristor configuration chosen for the Core Flow Test Loop power supply is presented. The initial considerations, design, and analysis of a closed-loop controller prototype are detailed. The design is then analyzed for improved performance possibilities and failure modes are investigated at length. A summary of the work completed to date and a proposed outline for continued development completes the report.

  16. Flow tests of the Gladys McCall well

    SciTech Connect

    Randolph, P.L.; Hayden, C.G.; Rogers, L.A. )

    1992-04-01

    This report pulls together the data from all of the geopressured-geothermal field research conducted at the Gladys McCall well. The well produced geopressured brine containing dissolved natural gas from the Lower Miocene sands at a depth of 15,150 to 16,650 feet. More than 25 million barrels of brine and 727 million standard cubic feet of natural gas were produced in a series of flow tests between December 1982 and October 1987 at various brine flow rates up to 28,000 barrels per day. Initial short-term flow tests for the Number 9 Sand found the permeability to be 67 to 85 md (millidarcies) for a brine volume of 85 to 170 million barrels. Initial short-term flow tests for the Number 8 Sand found a permeability of 113 to 132 md for a reservoir volume of 430 to 550 million barrels of brine. The long-term flow and buildup test of the Number 8 Sand found that the high-permeability reservoir connected to the wellbore (measured by the short-term flow test) was connected to a much larger, low-permeability reservoir. Numerical simulation of the flow and buildup tests required this large connected reservoir to have a volume of about 8 billion barrels (two cubic miles of reservoir rock) with effective permeabilities in the range of 0.2 to 20 md. Calcium carbonate scale formation in the well tubing and separator equipment was a problem. During the first 2 years of production, scale formation was prevented in the surface equipment by injection of an inhibitor upstream of the choke. Starting in 1985, scale formation in the production tubing was successfully prevented by injecting inhibitor pills'' directly into the reservoir. Corrosion and/or erosion of surface piping and equipment, as well as disposal well tubing, was also significant.

  17. Hanford Tank Farms Waste Certification Flow Loop Test Plan

    SciTech Connect

    Bamberger, Judith A.; Meyer, Perry A.; Scott, Paul A.; Adkins, Harold E.; Wells, Beric E.; Blanchard, Jeremy; Denslow, Kayte M.; Greenwood, Margaret S.; Morgen, Gerald P.; Burns, Carolyn A.; Bontha, Jagannadha R.

    2010-01-01

    A future requirement of Hanford Tank Farm operations will involve transfer of wastes from double shell tanks to the Waste Treatment Plant. As the U.S. Department of Energy contractor for Tank Farm Operations, Washington River Protection Solutions anticipates the need to certify that waste transfers comply with contractual requirements. This test plan describes the approach for evaluating several instruments that have potential to detect the onset of flow stratification and critical suspension velocity. The testing will be conducted in an existing pipe loop in Pacific Northwest National Laboratory’s facility that is being modified to accommodate the testing of instruments over a range of simulated waste properties and flow conditions. The testing phases, test matrix and types of simulants needed and the range of testing conditions required to evaluate the instruments are described

  18. Ground vibration test of the laminar flow control JStar airplane

    NASA Technical Reports Server (NTRS)

    Kehoe, M. W.; Cazier, F. W., Jr.; Ellison, J. F.

    1985-01-01

    A ground vibration test was conducted on a Lockheed JetStar airplane that had been modified for the purpose of conducting laminar flow control experiments. The test was performed prior to initial flight flutter tests. Both sine-dwell and single-point-random excitation methods were used. The data presented include frequency response functions and a comparison of mode frequencies and mode shapes from both methods.

  19. Mass-Flow-Meter Leak-Testing System

    NASA Technical Reports Server (NTRS)

    Sorensen, Eric B.; Polidori, Andre V.; Heman, Joe R.; Dresser, Holland L.; Hellum, John

    1996-01-01

    Improved leak-testing system incorporates mass-flow meter as primary sensor for measurement of leakage rate. System easier to use and more reliable and enables leak tests to be completed in less time. Produces test data more plentiful, more accurate, and better suited to leak detection and diagnosis. Operates over range of test conditions, including pressures from atmospheric to 1,000 psi, temperatures from 50 to 120 degrees F and volumes from less than 1 in.(sup3) to 22 in.(sup3). Sensitive enough to measure absorbed gas seeping from O-ring seals after test pressure released.

  20. Utility of models to predict 28-day or 30-day unplanned hospital readmissions: an updated systematic review

    PubMed Central

    Zhou, Huaqiong; Della, Phillip R; Roberts, Pamela; Goh, Louise; Dhaliwal, Satvinder S

    2016-01-01

    Objective To update previous systematic review of predictive models for 28-day or 30-day unplanned hospital readmissions. Design Systematic review. Setting/data source CINAHL, Embase, MEDLINE from 2011 to 2015. Participants All studies of 28-day and 30-day readmission predictive model. Outcome measures Characteristics of the included studies, performance of the identified predictive models and key predictive variables included in the models. Results Of 7310 records, a total of 60 studies with 73 unique predictive models met the inclusion criteria. The utilisation outcome of the models included all-cause readmissions, cardiovascular disease including pneumonia, medical conditions, surgical conditions and mental health condition-related readmissions. Overall, a wide-range C-statistic was reported in 56/60 studies (0.21–0.88). 11 of 13 predictive models for medical condition-related readmissions were found to have consistent moderate discrimination ability (C-statistic ≥0.7). Only two models were designed for the potentially preventable/avoidable readmissions and had C-statistic >0.8. The variables ‘comorbidities’, ‘length of stay’ and ‘previous admissions’ were frequently cited across 73 models. The variables ‘laboratory tests’ and ‘medication’ had more weight in the models for cardiovascular disease and medical condition-related readmissions. Conclusions The predictive models which focused on general medical condition-related unplanned hospital readmissions reported moderate discriminative ability. Two models for potentially preventable/avoidable readmissions showed high discriminative ability. This updated systematic review, however, found inconsistent performance across the included unique 73 risk predictive models. It is critical to define clearly the utilisation outcomes and the type of accessible data source before the selection of the predictive model. Rigorous validation of the predictive models with moderate-to-high discriminative

  1. Immunohistochemical study of motoneurons in lumbar spinal cord of c57black/6 mice after 30-days space flight

    NASA Astrophysics Data System (ADS)

    Tyapkina, Oksana; Islamov, Rustem; Nurullin, Leniz; Petrov, Konstantin.; Rezvyakov, Pavel; Nikolsky, Evgeny

    To investigate mechanisms of hypogravity motor syndrome development the immunoexpression of heat shock proteins (Hsp27 and Hsp70), proteins of synaptic transmission (Synaptophysin and PSD95) and neuroprotective proteins (VEGF and Flt-1) in motoneurons of lumbar spinal cord in c57black/6 control mice (n=2) and after 30-days space flight (n=2) was studied. For a quantitative assessment of target proteins level in motoneurons frozen cross sections of lumbar spinal cord were underwent to immunohistochemical staining. Primary antibodies against VEGF, Flt-1, Hsp27 and Hsp70 (SantaCruz Biotechnology, inc. USA), against Synaptophysin and PSD95 (Abcam plc, UK) were visualized by streptavidin-biotin method. Images of spinal cords were received using OlympusBX51WI microscope with AxioCamMRm camera (CarlZeiss, Germany) and the AxioVisionRel. 4.6.3 software (CarlZeiss, Germany). The digitized data were analyzed using ImageJ 1.43 software (NIH, the USA). Quantitively, protein level in motoneurons was estimated by the density of immunoprecipitation. Results of research have not revealed any reliable changes in the immunnoexpression of vascular endothelial growth factor (VEGF) and its Flt-1 receptor in motoneurons of lumbar spinal cord in control and in mice after 30-day space flight. Studying of heat shock proteins, such as Hsp27 and Hsp70, revealed the decrease in level of these proteins immunoexpression in motoneurons of mice from flight group by 15% and 10%, respectively. Some decrease in level of immunnoexpression of presynaptic membrane proteins (synaptophysin, by 21%) and proteins of postsynaptic area (PSD95, by 55%) was observed after space flight. The data obtained testify to possible changes in a functional state (synaptic activity and stress resistance) of motoneurons of lumbar spinal cord in mice after space flight. Thus, we obtained new data on involvement of motoneurons innervating skeletal muscles in development of hypogravity motor syndrome. Research was supported

  2. Design verification and cold-flow modeling test report

    SciTech Connect

    Not Available

    1993-07-01

    This report presents a compilation of the following three test reports prepared by TRW for Alaska Industrial Development and Export Authority (AIDEA) as part of the Healy Clean Coal Project, Phase 1 Design of the TRW Combustor and Auxiliary Systems, which is co-sponsored by the Department of Energy under the Clean Coal Technology 3 Program: (1) Design Verification Test Report, dated April 1993, (2) Combustor Cold Flow Model Report, dated August 28, 1992, (3) Coal Feed System Cold Flow Model Report, October 28, 1992. In this compilation, these three reports are included in one volume consisting of three parts, and TRW proprietary information has been excluded.

  3. Human performance profiles for planetary analog extra-vehicular activities: 120 day and 30 day analog missions

    NASA Astrophysics Data System (ADS)

    Swarmer, Tiffany M.

    Understanding performance factors for future planetary missions is critical for ensuring safe and successful planetary extra-vehicular activities (EVAs). The goal of this study was to gain operational knowledge of analog EVAs and develop biometric profiles for specific EVA types. Data was collected for a 120 and 30 day analog planetary exploration simulation focusing on EVA type, pre and post EVA conditions, and performance ratings. From this five main types of EVAs were performed: maintenance, science, survey/exploratory, public relations, and emergency. Each EVA type has unique characteristics and performance ratings showing specific factors in chronological components, environmental conditions, and EVA systems that have an impact on performance. Pre and post biometrics were collected to heart rate, blood pressure, and SpO2. Additional data about issues and specific EVA difficulties provide some EVA trends illustrating how tasks and suit comfort can negatively affect performance ratings. Performance decreases were noted for 1st quarter and 3rd quarter EVAs, survey/exploratory type EVAs, and EVAs requiring increased fine and gross motor function. Stress during the simulation is typically higher before the EVA and decreases once the crew has returned to the habitat. Stress also decreases as the simulation nears the end with the 3rd and 4th quarters showing a decrease in stress levels. Operational components and studies have numerous variable and components that effect overall performance, by increasing the knowledge available we may be able to better prepare future crews for the extreme environments and exploration of another planet.

  4. Increased in vivo glucose utilization in 30-day-old obese Zucker rat: Role of white adipose tissue

    SciTech Connect

    Krief, S.; Bazin, R.; Dupuy, F.; Lavau, M. )

    1988-03-01

    In vivo whole-body glucose utilization and uptake in multiple individual tissues were investigated in conscious 30-day-old Zucker rats, which when obese are hyperphagic, hyperinsulinemic, and normoglycemic. Whole-body glucose metabolism (assessed by (3-{sup 3}H)glucose) was 40% higher in obese (fa/fa) than in lean (Fa/fa) rats, suggesting that obese rats were quite responsive to their hyperinsulinemia. In obese compared with lean rats, tissue glucose uptake was increased by 15, 12, and 6 times in dorsal, inguinal, perigonadal white depots, respectively; multiplied by 2.5 in brown adipose tissue; increased by 50% in skin from inguinal region but not in that from cranial, thoracic, or dorsal area; and increased twofold in diaphragm but similar in heart in proximal intestine, and in total muscular mass of limbs. The data establish that in young obese rats the hypertrophied white adipose tissue was a major glucose-utilizing tissue whose capacity for glucose disposal compared with that of half the muscular mass. Adipose tissue could therefore play an important role in the homeostasis of glucose in obese rats in the face of their increased carbohydrate intake.

  5. Factors associated with moderate or severe left atrioventricular valve regurgitation within 30 days of repair of complete atrioventricular septal defect

    PubMed Central

    Kozak, Marcelo Felipe; Kozak, Ana Carolina Leiroz Ferreira Botelho Maisano; Marchi, Carlos Henrique De; Hassem Sobrinho Junior, Sirio; Croti, Ulisses Alexandre; Moscardini, Airton Camacho

    2015-01-01

    Introduction Left atrioventricular valve regurgitation is the most concerning residual lesion after surgical correction of atrioventricular septal defects. Objective To determine factors associated with moderate or severe left atrioventricular valve regurgitation within 30 days of surgical repair of complete atrioventricular septal defect. Methods We assessed the results of 53 consecutive patients 3 years-old and younger presenting with complete atrioventricular septal defect that were operated on at our practice between 2002 and 2010. The following variables were considered: age, weight, absence of Down syndrome, grade of preoperative atrioventricular valve regurgitation, abnormalities on the left atrioventricular valve and the use of annuloplasty. Median age was 6.7 months; median weight was 5.3 Kg; 86.8% had Down syndrome. At the time of preoperative evaluation, there were 26 cases with moderate or severe left atrioventricular valve regurgitation (49.1%). Abnormalities on the left atrioventricular valve were found in 11.3%; annuloplasty was performed in 34% of the patients. Results At the time of postoperative evaluation, there were 21 cases with moderate or severe left atrioventricular valve regurgitation (39.6%). After performing a multivariate analysis, the only significant factor associated with moderate or severe left atrioventricular valve regurgitation was the absence of Down syndrome (P=0.03). Conclusion Absence of Down syndrome was associated with moderate or severe postoperative left atrioventricular valve regurgitation after surgical repair of complete atrioventricular septal defect at our practice. PMID:26313720

  6. Effects on groundwater microbial communities of an engineered 30-day in situ exposure to the antibiotic sulfamethoxazole.

    PubMed

    Haack, Sheridan K; Metge, David W; Fogarty, Lisa R; Meyer, Michael T; Barber, Larry B; Harvey, Ronald W; Leblanc, Denis R; Kolpin, Dana W

    2012-07-17

    Effects upon microbial communities from environmental exposure to concentrations of antibiotics in the μg L(-1) range remain poorly understood. Microbial communities from an oligotrophic aquifer (estimated doubling rates of only once per week) that were previously acclimated (AC) or unacclimated (UAC) to historical sulfamethoxazole (SMX) contamination, and a laboratory-grown Pseudomonas stutzeri strain, were exposed to 240-520 μg L(-1) SMX for 30 days in situ using filter chambers allowing exposure to ambient groundwater, but not to ambient microorganisms. SMX-exposed UAC bacterial communities displayed the greatest mortality and impairment (viable stain assays), the greatest change in sensitivity to SMX (dose-response assays), and the greatest change in community composition (Terminal Restriction Fragment Length Polymorphism; T-RFLP). The sul1 gene, encoding resistance to SMX at clinically relevant levels, and an element of Class I integrons, was not detected in any community. Changes in microbial community structure and SMX resistance over a short experimental period in previously nonexposed, slow-growing aquifer communities suggest concentrations of antibiotics 2-3 orders of magnitude less than those used in clinical applications may influence ecological function through changes in community composition, and could promote antibiotic resistance through selection of naturally resistant bacteria.

  7. Effects of 30 day simulated microgravity and recovery on fluid homeostasis and renal function in the rat

    NASA Technical Reports Server (NTRS)

    Tucker, Bryan J.; Mendonca, Margarida M.

    1995-01-01

    Transition from a normal gravitational environment to that of microgravity eventually results in decreased plasma and blood volumes, increasing with duration of exposure to microgravity. This loss of vascular fluid is presumably due to negative fluid and electrolyte balance and most likely contributes to the orthostatic intolerance associated with the return to gravity. The decrease in plasma volume is presumed to be a reflection of a concurrent decrease in extracellular fluid volume with maintenance of normal plasma-interstitial fluid balance. In addition, the specific alterations in renal function contributing to these changes in fluid and electrolyte homeostasis are potentially responding to neuro-humoral signals that are not consistent with systemic fluid volume status. We have previously demonstrated an early increase in both glomerular filtration rate and extracellular fluid volume and that this decreases towards control values by 7 days of simulated microgravity. However, longer duration studies relating these changes to plasma volume alterations and the response to return to orthostasis have not been fully addressed. Male Wistar rats were chronically cannulated, submitted to 30 days heat-down tilt (HDT) and followed for 7 days after return to orthostasis from HDT. Measurements of renal function and extracellular and blood volumes were performed in the awake rat.

  8. The migraine generator revisited: continuous scanning of the migraine cycle over 30 days and three spontaneous attacks.

    PubMed

    Schulte, Laura H; May, Arne

    2016-07-01

    Functional imaging using positron emission tomography and later functional magnetic resonance imaging revealed a particular brainstem area that is believed to be specifically activated in migraine during, but not outside of the attack, and consequently has been coined the 'migraine generator'. However, the pathophysiological concept behind this term is not undisputed and typical migraine premonitory symptoms such as fatigue and yawning, but also a typical association of attacks to circadian and menstrual cycles, all make the hypothalamus a possible regulating region of migraine attacks. Neuroimaging studies investigating native human migraine attacks however are scarce and for methodological but also clinical reasons there are currently no studies investigating the last 24 h before headache onset. Here we report a migraine patient who had magnetic resonance imaging every day for 30 days, always in the morning, to cover, using functional imaging, a whole month and three complete, untreated migraine attacks. We found that hypothalamic activity as a response to trigeminal nociceptive stimulation is altered during the 24 h prior to pain onset, i.e. increases towards the next migraine attack. More importantly, the hypothalamus shows altered functional coupling with the spinal trigeminal nuclei and the region of the migraine generator, i.e. the dorsal rostral pons during the preictal day and the pain phase of native human migraine attacks. These data suggest that although the brainstem is highly linked to the migraine biology, the real driver of attacks might be the functional changes in hypothalamo-brainstem connectivity.

  9. Flow Visualization of Liquid Hydrogen Line Chilldown Tests

    NASA Technical Reports Server (NTRS)

    Rame, Enrique; Hartwig, Jason W.; McQuillen John B.

    2014-01-01

    We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.

  10. Countercurrent Flow of Molten Glass and Air during Siphon Tests

    SciTech Connect

    Guerrero, H.N.

    2001-01-16

    Siphon tests of molten glass were performed to simulate potential drainage of a radioactive waste melter, the Defense Waste Processing Facility (DWPF) at the Savannah River Site. Glass is poured from the melter through a vertical downspout that is connected to the bottom of the melter through a riser. Large flow surges have the potential of completely filling the downspout and creating a siphon effect that has the potential for complete draining of the melter. Visual observations show the exiting glass stream starts as a single-phase pipe flow, constricting into a narrow glass stream. Then a half-spherical bubble forms at the exit of the downspout. The bubble grows, extending upwards into the downspout, while the liquid flows counter-currently to one side of the spout. Tests were performed to determine what are the spout geometry and glass properties that would be conducive to siphoning, conditions for terminating the siphon, and the total amount of glass drained.

  11. VERIFICATION TESTING OF WET-WEATHER FLOW TECHNOLOGIES

    EPA Science Inventory

    As part of the USEPA's ETV Program, the Wet-Weather Flow (WWF) Technologies Pilot Program verifies the performance of commercial-ready technologies by generating quality-assured data using test protocols developed with broad-based stakeholder input. The availability of a credible...

  12. In vitro heart valve testing: steady versus pulsatile flow.

    PubMed

    Black, M M; Hose, D R; Lamb, C J; Lawford, P V; Ralph, S J

    1994-03-01

    The design of artificial heart valves has traditionally been based on the development of a prototype device which was then subjected to extensive laboratory testing in order to confirm its suitability for clinical use. In the past the in vitro assessment of a valve's performance was based principally on the measurement of parameters such as pressure difference, regurgitation and, more recently, energy losses. Such measurements can be defined as being at the 'macro' level and rarely show any clinically significant differences amongst currently available prostheses. The analytical approach to flow through heart valves has previously been hampered by difficulties experienced in solving the relevant equations of flow particularly in the case of pulsatile conditions. Computational techniques are now available which enable appropriate solutions to be obtained for these problems and consequently provide an opportunity for detailed examination of the 'micro' level of flow disturbances exhibited by the different valves. This present preliminary study is designed to illustrate the use of such an analytical approach to the flow through prosthetic valves. A single topic has been selected for this purpose which is the comparative value of steady versus pulsatile flow testing. A bileaflet valve was chosen for the analysis and a mathematical model of this valve in the aortic position of the Sheffield Pulse Duplicator was created. The theoretical analysis was carried out using a commercially available Computational Fluid Dynamics package, namely, FIDAP, on a SUN MICROSYSTEMS 10-30 workstation.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. A Public-Private Partnership Develops and Externally Validates a 30-Day Hospital Readmission Risk Prediction Model

    PubMed Central

    Choudhry, Shahid A.; Li, Jing; Davis, Darcy; Erdmann, Cole; Sikka, Rishi; Sutariya, Bharat

    2013-01-01

    Introduction: Preventing the occurrence of hospital readmissions is needed to improve quality of care and foster population health across the care continuum. Hospitals are being held accountable for improving transitions of care to avert unnecessary readmissions. Advocate Health Care in Chicago and Cerner (ACC) collaborated to develop all-cause, 30-day hospital readmission risk prediction models to identify patients that need interventional resources. Ideally, prediction models should encompass several qualities: they should have high predictive ability; use reliable and clinically relevant data; use vigorous performance metrics to assess the models; be validated in populations where they are applied; and be scalable in heterogeneous populations. However, a systematic review of prediction models for hospital readmission risk determined that most performed poorly (average C-statistic of 0.66) and efforts to improve their performance are needed for widespread usage. Methods: The ACC team incorporated electronic health record data, utilized a mixed-method approach to evaluate risk factors, and externally validated their prediction models for generalizability. Inclusion and exclusion criteria were applied on the patient cohort and then split for derivation and internal validation. Stepwise logistic regression was performed to develop two predictive models: one for admission and one for discharge. The prediction models were assessed for discrimination ability, calibration, overall performance, and then externally validated. Results: The ACC Admission and Discharge Models demonstrated modest discrimination ability during derivation, internal and external validation post-recalibration (C-statistic of 0.76 and 0.78, respectively), and reasonable model fit during external validation for utility in heterogeneous populations. Conclusions: The ACC Admission and Discharge Models embody the design qualities of ideal prediction models. The ACC plans to continue its partnership to

  14. A contemporary risk model for predicting 30-day mortality following percutaneous coronary intervention in England and Wales

    PubMed Central

    McAllister, Katherine S.L.; Ludman, Peter F.; Hulme, William; de Belder, Mark A.; Stables, Rodney; Chowdhary, Saqib; Mamas, Mamas A.; Sperrin, Matthew; Buchan, Iain E.

    2016-01-01

    Background The current risk model for percutaneous coronary intervention (PCI) in the UK is based on outcomes of patients treated in a different era of interventional cardiology. This study aimed to create a new model, based on a contemporary cohort of PCI treated patients, which would: predict 30 day mortality; provide good discrimination; and be well calibrated across a broad risk-spectrum. Methods and results The model was derived from a training dataset of 336,433 PCI cases carried out between 2007 and 2011 in England and Wales, with 30 day mortality provided by record linkage. Candidate variables were selected on the basis of clinical consensus and data quality. Procedures in 2012 were used to perform temporal validation of the model. The strongest predictors of 30-day mortality were: cardiogenic shock; dialysis; and the indication for PCI and the degree of urgency with which it was performed. The model had an area under the receiver operator characteristic curve of 0.85 on the training data and 0.86 on validation. Calibration plots indicated a good model fit on development which was maintained on validation. Conclusion We have created a contemporary model for PCI that encompasses a range of clinical risk, from stable elective PCI to emergency primary PCI and cardiogenic shock. The model is easy to apply and based on data reported in national registries. It has a high degree of discrimination and is well calibrated across the risk spectrum. The examination of key outcomes in PCI audit can be improved with this risk-adjusted model. PMID:26942330

  15. The statistical extended-range (10-30-day) forecast of summer rainfall anomalies over the entire China

    NASA Astrophysics Data System (ADS)

    Zhu, Zhiwei; Li, Tim

    2016-03-01

    The extended-range (10-30-day) rainfall forecast over the entire China was carried out using spatial-temporal projection models (STPMs). Using a rotated empirical orthogonal function analysis of intraseasonal (10-80-day) rainfall anomalies, China is divided into ten sub-regions. Different predictability sources were selected for each of the ten regions. The forecast skills are ranked for each region. Based on temporal correlation coefficient (TCC) and Gerrity skill score, useful skills are found for most parts of China at a 20-25-day lead. The southern China and the mid-lower reaches of Yangtze River Valley show the highest predictive skills, whereas southwestern China and Huang-Huai region have the lowest predictive skills. By combining forecast results from ten regional STPMs, the TCC distribution of 8-year (2003-2010) independent forecast for the entire China is investigated. The combined forecast results from ten STPMs show significantly higher skills than the forecast with just one single STPM for the entire China. Independent forecast examples of summer rainfall anomalies around the period of Beijing Olympic Games in 2008 and Shanghai World Expo in 2010 are presented. The result shows that the current model is able to reproduce the gross pattern of the summer intraseasonal rainfall over China at a 20-day lead. The present study provides, for the first time, a guide on the statistical extended-range forecast of summer rainfall anomalies for the entire China. It is anticipated that the ideas and methods proposed here will facilitate the extended-range forecast in China.

  16. Inclusion of Dynamic Clinical Data Improves the Predictive Performance of a 30-Day Readmission Risk Model in Kidney Transplantation

    PubMed Central

    Taber, David J; Palanisamy, Arun P; Srinivas, Titte R; Gebregziabher, Mulugeta; Odeghe, John; Chavin, Kenneth D; Egede, Leonard E; Baliga, Prabhakar K

    2015-01-01

    Background 30-day readmissions (30DRA) are a highly scrutinized measure of healthcare quality and relatively frequent among kidney transplants (KTX). Development of predictive risk models are critical to reducing 30DRA and improving outcomes. Current approaches rely on fixed variables derived from administrative data. These models may not capture clinical evolution that is critical to predicting outcomes. Methods We directed a retrospective analysis towards: 1) developing parsimonious risk models for 30DRA and 2) comparing efficiency of models based on the use of immutable versus dynamic data. Baseline and in-hospital clinical and outcomes data were collected from adult KTX recipients between 2005 – 12. Risk models were developed using backward logistic regression and compared for predictive efficacy using ROC Curves. Results Of 1,147 KTX patients, 123 had 30DRA. Risk factors for 30DRA included recipient comorbidities, transplant factors, and index hospitalization patient level clinical data. The initial fixed variable model included 9 risk factors and was modestly predictive (AUC 0.64, 95% CI 0.58–0.69). The model was parsimoniously reduced to 6 risks, which remained modestly predictive (AUC 0.63, 95% CI 0.58–0.69). The initial predictive model using 13 fixed and dynamic variables was significantly predictive (AUC 0.73, 95% CI 0.67–0.80), with parsimonious reduction to 9 variables maintaining predictive efficacy (AUC 0.73, 95% CI 0.67–0.79). The final model using dynamically evolving clinical data outperformed the model using static variables (p=0.009). Internal validation demonstrated the final model was stable with minimal bias. Conclusion We demonstrate that modeling dynamic clinical data outperformed models utilizing immutable data in predicting 30DRA. PMID:25594549

  17. Flow-Field Survey in the Test Region of the SR-71 Aircraft Test Bed Configuration

    NASA Technical Reports Server (NTRS)

    Mizukami, Masashi; Jones, Daniel; Weinstock, Vladimir D.

    2000-01-01

    A flat plate and faired pod have been mounted on a NASA SR-71A aircraft for use as a supersonic flight experiment test bed. A test article can be placed on the flat plate; the pod can contain supporting systems. A series of test flights has been conducted to validate this test bed configuration. Flight speeds to a maximum of Mach 3.0 have been attained. Steady-state sideslip maneuvers to a maximum of 2 deg have been conducted, and the flow field in the test region has been surveyed. Two total-pressure rakes, each with two flow-angle probes, have been placed in the expected vicinity of an experiment. Static-pressure measurements have been made on the flat plate. At subsonic and low supersonic speeds with no sideslip, the flow in the surveyed region is quite uniform. During sideslip maneuvers, localized flow distortions impinge on the test region. Aircraft sideslip does not produce a uniform sidewash over the test region. At speeds faster than Mach 1.5, variable-pressure distortions were observed in the test region. Boundary-layer thickness on the flat plate at the rake was less than 2.1 in. For future experiments, a more focused and detailed flow-field survey than this one would be desirable.

  18. Flow and diffusion of high-stakes test scores

    NASA Astrophysics Data System (ADS)

    Marder, M.; Bansal, D.

    2009-10-01

    We apply visualization and modeling methods for convective and diffusive flows to public school mathematics test scores from Texas. We obtain plots that show the most likely future and past scores of students, the effects of random processes such as guessing, and the rate at which students appear in and disappear from schools. We show that student outcomes depend strongly upon economic class, and identify the grade levels where flows of different groups diverge most strongly. Changing the effectiveness of instruction in one grade naturally leads to strongly nonlinear effects on student outcomes in subsequent grades.

  19. The 2013 German-Russian BION-M1 Joint Flight Project: Skeletal Muscle and Neuromuscular Changes in Mice Housed for 30 Days in a Biosatellite on Orbit

    NASA Astrophysics Data System (ADS)

    Blottner, Dieter; Shenkman, Boris; Salanova, Michele

    Exposure to microgravity results in various structural, biochemical and molecular changes of the skeletal neuromuscular system. The BION Joint Flight Proposal between the Charité Berlin Center of Space Medicine (www.zwmb.de) in Berlin, and the Institute of Biomedical Problem (IMBP) in Moscow, provided an exciting opportunity for a more detailed analysis of neuromuscular changes in mice (C57/bl6) exposed to real microgravity housed for 30 days in a BION M1 biosatellite on orbit. The mice from the BION flight group (n=5) were compared to three different on-ground control groups (Flight control, BION-ground and Vivarium, each n=5 mice). We started to analyse various skeletal muscles from the hind limbs or trunk. Apart from routine structural and biochemical analysis (fiber size and type distribution, slow/fastMyHC) we test the hypothesis for the presence of a microgravity-induced sarcolemma-cytosolic protein shift of nitric oxide synthase (NOS) and partial loss in neuromuscular synapse scaffold protein (Homer) immunoexpression known to be prone to disuse in mice or humans (hind limb unloading, bed rest) as previously shown (Sandonà D et al., PLoS One, 2012, Salanova M et al., FASEB J, 2011). National Sponsors: Federal Ministry of Economics and Technology (BMWi) via the German AeroSpace Board, DLR e.V., Bonn-Oberkassel, Germany (#50WB1121); Contract RAS-IMBP/Charité Berlin # Bion-M1/2013

  20. Patients more likely to engage in treatment at 30 days when given buprenorphine in the ED, referred for follow-up.

    PubMed

    2015-08-01

    A new randomized trial shows patients who present to the ED with opioid dependence are much more likely to engage in treatment when they receive buprenorphine along with coordinated follow-up than when they just receive a brief intervention and a facilitated referral for treatment or just screening and referral. However, barriers to prescribing are robust, and many ED leaders are not persuaded they should be in the business of providing treatment for addiction. In the trial, at 30 days 78% of patients in the buprenorphine group (89 of 114 patients) were engaged in addiction treatment, compared with just 45% of the patients in the brief intervention group (50 of 111 patients) and 37% of patients in the referral group (38 of 102 patients). To prescribe buprenorphine for addiction disease, providers must undergo training and pass a test to obtain a DEA waiver; they are limited to treating 100 patients. While experts note there are not enough providers to prescribe buprenorphine and provide the follow-up needed to patients with addiction disease, they also acknowledge concerns about drug diversion as well as potential problems with capacity if EDs take a larger role in treating addiction. PMID:26258203

  1. Nonclinical Factors Associated with 30-Day Mortality after Lung Cancer Resection: An Analysis of 215,000 Patients Using the National Cancer Data Base

    PubMed Central

    Melvan, John N; Sancheti, Manu S; Gillespie, Theresa; Nickleach, Dana C; Liu, Yuan; Higgins, Kristin; Ramalingam, Suresh; Lipscomb, Joseph; Fernandez, Felix G

    2015-01-01

    Background Clinical variables associated with 30-day mortality after lung cancer surgery are well known. However, the effects of non-clinical factors, including insurance coverage, household income, education, type of treatment center, and area of residence, on short term survival are less appreciated. We studied the National Cancer Data Base (NCDB), a joint endeavor of the Commission on Cancer of the American College of Surgeons and the American Cancer Society, to identify disparities in 30-day mortality after lung cancer resection based on these non-clinical factors. Study Design We performed a retrospective cohort analysis of patients undergoing lung cancer resection from 2003-2011, using the NCDB. Data were analyzed using a multivariable logistic regression model to identify risk factors for 30-day mortality. Results 215,645 patients underwent lung cancer resection during our study period. We found that clinical variables such as age, gender, comorbidity, cancer stage, preoperative radiation, extent of resection, positive surgical margins, and tumor size were associated with 30-day mortality after resection. Non-clinical factors including living in lower income neighborhoods with a lesser proportion of high school graduates, and receiving cancer care at a non-academic medical center were also independently associated with increased 30-day postoperative mortality. Conclusions This study represents the largest analysis of 30-day mortality for lung cancer resection to date from a generalizable national cohort. Our results demonstrate that, in addition to known clinical risk factors, several non-clinical factors are associated with increased 30-day mortality after lung cancer resection. These disparities require further investigation to improve lung cancer patient outcomes. PMID:26206651

  2. Cold Flow Plume Entrainment Test Final Report NTF Test Number 2456

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph H.; McDaniels, David; Mishtawy, Jason; Ramachandran, Narayanan; Hammad, Khaled J.

    2005-01-01

    As part of the Space Shuttle Return to Flight (RTF) program, Marshall Space Flight Center (MSFC) performed computational fluid dynamics (CFD) analysis to define the velocity flowfields around the Shuttle stack at liftoff. These CFD predicted velocity flowfields were used in debris transport analysis (DTA). High speed flows such as plumes induce or 'entrain' mass from the surrounding environment. Previous work had shown that CFD analysis over-predicts plume induced flows. Therefore, the DTA would tend to 1) predict more debris impacts, and 2) the debris velocity (and kinetic energy) of those impacts would be too high. At a November, 2004 peer-review it was recommended that the Liftoff DTA team quantify the uncertainty in the DTA caused by the CFD's over prediction of plume induced flow. To do so, the Liftoff DTA team needed benchmark quality data for plume induced flow to quantify the CFD accuracy and its effect on the DTA. MSFC's Nozzle Test Facility (NTF) conducted the "Nozzle Induced Flows test, P#2456" to obtain experimental data for plume induced flows for nozzle flow exhausting into q quiescent freestream. Planning for the test began in December, 2004 and the experimental data was obtained in February and March of 2005. The funding for this test was provided by MSFC's Space Shuttle Propulsion Systems Integration and Engineering office.

  3. Measurements of Turbulent Flow Field in Separate Flow Nozzles with Enhanced Mixing Devices - Test Report

    NASA Technical Reports Server (NTRS)

    Bridges, James

    2002-01-01

    As part of the Advanced Subsonic Technology Program, a series of experiments was conducted at NASA Glenn Research Center on the effect of mixing enhancement devices on the aeroacoustic performance of separate flow nozzles. Initial acoustic evaluations of the devices showed that they reduced jet noise significantly, while creating very little thrust loss. The explanation for the improvement required that turbulence measurements, namely single point mean and RMS statistics and two-point spatial correlations, be made to determine the change in the turbulence caused by the mixing enhancement devices that lead to the noise reduction. These measurements were made in the summer of 2000 in a test program called Separate Nozzle Flow Test 2000 (SFNT2K) supported by the Aeropropulsion Research Program at NASA Glenn Research Center. Given the hot high-speed flows representative of a contemporary bypass ratio 5 turbofan engine, unsteady flow field measurements required the use of an optical measurement method. To achieve the spatial correlations, the Particle Image Velocimetry technique was employed, acquiring high-density velocity maps of the flows from which the required statistics could be derived. This was the first successful use of this technique for such flows, and shows the utility of this technique for future experimental programs. The extensive statistics obtained were likewise unique and give great insight into the turbulence which produces noise and how the turbulence can be modified to reduce jet noise.

  4. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    SciTech Connect

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs.

  5. Flap survey test of a combined surface blowing model: Flow measurements at static flow conditions

    NASA Technical Reports Server (NTRS)

    Fukushima, T.

    1978-01-01

    The Combined Surface Blowing (CSB) V/STOL lift/propulsion system consists of a blown flap system which deflects the exhaust from a turbojet engine over a system of flaps deployed at the trailing edge of the wing. Flow measurements consisting of velocity measurements using split film probes and total measure surveys using a miniature Kiel probe were made at control stations along the flap systems at two spanwise stations, the centerline of the nozzle and 60 percent of the nozzle span outboard of the centerline. Surface pressure measurements were made in the wing cove and the upper surface of the first flap element. The test showed a significant flow separation in the wing cove. The extent of the separation is so large that the flow into the first flap takes place only at the leading edge of the flap. The velocity profile measurements indicate that large spanwise (3 dimensional) flow may exist.

  6. Universal Verification Methodology Based Register Test Automation Flow.

    PubMed

    Woo, Jae Hun; Cho, Yong Kwan; Park, Sun Kyu

    2016-05-01

    In today's SoC design, the number of registers has been increased along with complexity of hardware blocks. Register validation is a time-consuming and error-pron task. Therefore, we need an efficient way to perform verification with less effort in shorter time. In this work, we suggest register test automation flow based UVM (Universal Verification Methodology). UVM provides a standard methodology, called a register model, to facilitate stimulus generation and functional checking of registers. However, it is not easy for designers to create register models for their functional blocks or integrate models in test-bench environment because it requires knowledge of SystemVerilog and UVM libraries. For the creation of register models, many commercial tools support a register model generation from register specification described in IP-XACT, but it is time-consuming to describe register specification in IP-XACT format. For easy creation of register model, we propose spreadsheet-based register template which is translated to IP-XACT description, from which register models can be easily generated using commercial tools. On the other hand, we also automate all the steps involved integrating test-bench and generating test-cases, so that designers may use register model without detailed knowledge of UVM or SystemVerilog. This automation flow involves generating and connecting test-bench components (e.g., driver, checker, bus adaptor, etc.) and writing test sequence for each type of register test-case. With the proposed flow, designers can save considerable amount of time to verify functionality of registers. PMID:27483924

  7. Analysis of Alcove 8/Niche 3 Flow and Transport Tests

    SciTech Connect

    H.H. Liu

    2006-09-01

    The purpose of this report is to document analyses of the Alcove 8/Niche 3 flow and transport tests, with a focus on the large-infiltration-plot tests and compare pre-test model predictions with the actual test observations. The tests involved infiltration that originated from the floor of Alcove 8 (located in the Enhanced Characterization of Repository Block (ECRB) Cross Drift) and observations of seepage and tracer transport at Niche 3 (located in the Main Drift of the Exploratory Studies Facility (ESF)). The test results are relevant to drift seepage and solute transport in the unsaturated zone (UZ) of Yucca Mountain. The main objective of this analysis was to evaluate the modeling approaches used and the importance of the matrix diffusion process by comparing simulation and actual test observations. The pre-test predictions for the large plot test were found to differ from the observations and the reasons for the differences were documented in this report to partly address CR 6783, which concerns unexpected test results. These unexpected results are discussed and assessed with respect to the current baseline unsaturated zone radionuclide transport model in Sections 6.2.4, 6.3.2, and 6.4.

  8. Jet-Surface Interaction Test: Flow Measurements Results

    NASA Technical Reports Server (NTRS)

    Brown, Cliff; Wernet, Mark

    2014-01-01

    Modern aircraft design often puts the engine exhaust in close proximity to the airframe surfaces. Aircraft noise prediction tools must continue to develop in order to meet the challenges these aircraft present. The Jet-Surface Interaction Tests have been conducted to provide a comprehensive quality set of experimental data suitable for development and validation of these exhaust noise prediction methods. Flow measurements have been acquired using streamwise and cross-stream particle image velocimetry (PIV) and fluctuating surface pressure data acquired using flush mounted pressure transducers near the surface trailing edge. These data combined with previously reported far-field and phased array noise measurements represent the first step toward the experimental data base. These flow data are particularly applicable to development of noise prediction methods which rely on computational fluid dynamics to uncover the flow physics. A representative sample of the large flow data set acquired is presented here to show how a surface near a jet affects the turbulent kinetic energy in the plume, the spatial relationship between the jet plume and surface needed to generate surface trailing-edge noise, and differences between heated and unheated jet flows with respect to surfaces.

  9. Development and use of an administrative claims measure for profiling hospital-wide performance on 30-day unplanned readmission

    PubMed Central

    Horwitz, Leora I.; Partovian, Chohreh; Lin, Zhenqiu; Grady, Jacqueline N.; Herrin, Jeph; Conover, Mitchell; Montague, Julia; Dillaway, Chloe; Bartczak, Kathleen; Suter, Lisa G.; Ross, Joseph S.; Bernheim, Susannah M.; Krumholz, Harlan M.; Drye, Elizabeth E.

    2014-01-01

    Background Existing publicly-reported readmission measures are condition-specific, representing < 20% of adult hospitalizations. An all-condition measure may better measure quality and promote innovation. Objective To develop an all-condition, hospital-wide readmission measure. Design Measure development Setting 4,821 US hospitals. Patients Medicare Fee for Service (FFS) beneficiaries ≥ 65 years. Measurements Hospital-level, risk-standardized unplanned readmissions within 30 days of discharge. The measure uses Medicare FFS claims and is a composite of five specialty-based risk-standardized rates for medicine, surgery/gynecology, cardiorespiratory, cardiovascular and neurology cohorts. We randomly split the 2007–2008 admissions for development and validation. Models were adjusted for age, principal diagnosis and comorbidity. We examined calibration in Medicare and all-payer data, and compared hospital rankings in the development and validation samples. Results The development dataset contained 8,018,949 admissions associated with 1,276,165 unplanned readmissions (15.9%). The median hospital risk-standardized unplanned readmission rate was 15.8 (range 11.6–21.9). The five specialty cohort models accurately predicted readmission risk in both Medicare and all-payer datasets for average risk patients but slightly overestimated readmission risk at the extremes. Overall hospital risk-standardized readmission rates did not differ statistically in the split samples (p=0.7 for difference in rank) and 76% of hospitals’ validation set rankings were within two deciles of the development rank (24% >2 deciles). Of hospitals ranking in the top or bottom deciles, 90% remained within two deciles (10% >2 deciles), and 82% remained within one decile (18% > 1 decile). Limitations Risk-adjustment was limited to that available in claims data. Conclusions We developed a claims-based hospital-wide unplanned readmission measure for profiling hospitals that produced reasonably

  10. Flammable gas interlock spoolpiece flow response test report

    SciTech Connect

    Schneider, T.C., Fluor Daniel Hanford

    1997-03-24

    The purpose of this test report is to document the testing performed under the guidance of HNF-SD-WM-TC-073, {ital Flammable Gas Interlock Spoolpiece Flow Response Test Plan and Procedure}. This testing was performed for Lockheed Martin Hanford Characterization Projects Operations (CPO) in support of Rotary Mode Core Sampling jointly by SGN Eurisys Services Corporation and Numatec Hanford Company. The testing was conducted in the 305 building Engineering Testing Laboratory (ETL). NHC provides the engineering and technical support for the 305 ETL. The key personnel identified for the performance of this task are as follows: Test responsible engineering manager, C. E. Hanson; Flammable Gas Interlock Design Authority, G. P. Janicek; 305 ETL responsible manager, N. J. Schliebe; Cognizant RMCS exhauster engineer, E. J. Waldo/J. D. Robinson; Cognizant 305 ETL engineer, K. S. Witwer; Test director, T. C. Schneider. Other support personnel were supplied, as necessary, from 305/306 ETL. The testing, on the flammable Gas Interlock (FGI) system spoolpiece required to support Rotary Mode Core Sampling (RMCS) of single shell flammable gas watch list tanks, took place between 2-13-97 and 2-25-97.

  11. On cavity flow permeability testing of a sandstone.

    PubMed

    Selvadurai, P A; Selvadurai, A P S

    2007-01-01

    This paper describes a laboratory experiment designed to measure the bulk permeability of a cuboidal sample of sandstone measuring approximately 450 mm(2) in plan area and 508 mm in height. The relatively large dimensions of the sandstone specimen allow the determination of the permeability of the material by creating a central cavity that can be pressurized to maintain a constant flow rate. The paper describes the experimental details and the test procedure, and discusses the computational and analytic approaches that have been used to interpret the test results.

  12. Facility for cold flow testing of solid rocket motor models

    NASA Astrophysics Data System (ADS)

    Bacchus, D. L.; Hill, O. E.; Whitesides, R. Harold

    1992-02-01

    A new cold flow test facility was designed and constructed at NASA Marshall Space Flight Center for the purpose of characterizing the flow field in the port and nozzle of solid propellant rocket motors (SRM's). A National Advisory Committee was established to include representatives from industry, government agencies, and universities to guide the establishment of design and instrumentation requirements for the new facility. This facility design includes the basic components of air storage tanks, heater, submicron filter, quiet control valve, venturi, model inlet plenum chamber, solid rocket motor (SRM) model, exhaust diffuser, and exhaust silencer. The facility was designed to accommodate a wide range of motor types and sizes from small tactical motors to large space launch boosters. This facility has the unique capability of testing ten percent scale models of large boosters such as the new Advanced Solid Rocket Motor (ASRM), at full scale motor Reynolds numbers. Previous investigators have established the validity of studying basic features of solid rocket motor development programs include the acquisition of data to (1) directly evaluate and optimize the design configuration of the propellant grain, insulation, and nozzle; and (2) provide data for validation of the computational fluid dynamics, (CFD), analysis codes and the performance analysis codes. A facility checkout model was designed, constructed, and utilized to evaluate the performance characteristics of the new facility. This model consists of a cylindrical chamber and converging/diverging nozzle with appropriate manifolding to connect it to the facility air supply. It was designed using chamber and nozzle dimensions to simulate the flow in a 10 percent scale model of the ASRM. The checkout model was recently tested over the entire range of facility flow conditions which include flow rates from 9.07 to 145 kg/sec (20 to 320 Ibm/sec) and supply pressure from 5.17 x 10 exp 5 to 8.27 x 10 exp 6 Pa. The

  13. The dipole flow test: A new single-borehole test for aquifer characterization

    SciTech Connect

    Kabala, Z.J. )

    1993-01-01

    A new single-borehole measurement technique for confined aquifers, the dipole flow test, yields the vertical distributions of the horizontal hydraulic conductivity, the vertical hydraulic conductivity, and the specific storativity when applied to different borehole intervals. The test utilizes straddle packers to isolate two chambers in the borehole, pressure transducers to monitor drawdown in them, and a small pump to create a dipole flow pattern in the aquifer by pumping water at a constant rate from the aquifer into one chamber, transferring it within the well to the next chamber, and finally injecting it back to the aquifer. A mathematical model describing the drawdown in each chamber is derived for the transient as well as the steady state cases. The aquifer parameters may be estimated from data produced by the dipole flow test alone or in conjunction with conventional pumping tests. The dipole flow regime reaches a steady state relatively quickly, especially in well permeable aquifers. A robust computational methodology for estimating the aquifer parameters, suitable for automatization, is based on the Newton-Raphson algorithm applied to a system of up to three nonlinear equations, each describing the well drawdown at a different judiciously chosen time. Due to the relatively small drawdown it invokes, the dipole flow test may be applicable to unconfined aquifers as well.

  14. Extent of Surgery Does Not Influence 30-Day Mortality in Surgery for Metastatic Bone Disease: An Observational Study of a Historical Cohort.

    PubMed

    Sørensen, Michala Skovlund; Hindsø, Klaus; Hovgaard, Thea Bechmann; Petersen, Michael Mørk

    2016-04-01

    Estimating patient survival has hitherto been the main focus when treating metastatic bone disease (MBD) in the appendicular skeleton. This has been done in an attempt to allocate the patient to a surgical procedure that outlives them. No questions have been addressed as to whether the extent of the surgery and thus the surgical trauma reduces survival in this patient group. We wanted to evaluate if perioperative parameters such as blood loss, extent of bone resection, and duration of surgery were risk factors for 30-day mortality in patients having surgery due to MBD in the appendicular skeleton. We retrospectively identified 270 consecutive patients who underwent joint replacement surgery or intercalary spacing for skeletal metastases in the appendicular skeleton from January 1, 2003 to December 31, 2013. We collected intraoperative (duration of surgery, extent of bone resection, and blood loss), demographic (age, gender, American Society of Anesthesiologist score [ASA score], and Karnofsky score), and disease-specific (primary cancer) variables. An association with 30-day mortality was addressed using univariate and multivariable analyses and calculation of odds ratio (OR). All patients were included in the analysis. ASA score 3 + 4 (OR 4.16 [95% confidence interval, CI, 1.80-10.85], P = 0.002) and Karnofsky performance status below 70 (OR 7.34 [95% CI 3.16-19.20], P < 0.001) were associated with increased 30-day mortality in univariate analysis. This did not change in multivariable analysis. No parameters describing the extent of the surgical trauma were found to be associated with 30-day mortality. The 30-day mortality in patients undergoing surgery for MBD is highly dependent on the general health status of the patients as measured by the ASA score and the Karnofsky performance status. The extent of surgery, measured as duration of surgery, blood loss, and degree of bone resection were not associated with 30-day mortality.

  15. Lateral flow-based antibody testing for Chlamydia trachomatis.

    PubMed

    Gwyn, Sarah; Mitchell, Alexandria; Dean, Deborah; Mkocha, Harran; Handali, Sukwan; Martin, Diana L

    2016-08-01

    We describe here a lateral flow-based assay (LFA) for the detection of antibodies against immunodominant antigen Pgp3 from Chlamydia trachomatis, the causative agent of urogenital chlamydia infection and ocular trachoma. Optimal signal detection was achieved when the gold-conjugate and test line contained Pgp3, creating a dual sandwich capture assay. The LFA yielded positive signals with serum and whole blood but not with eluted dried blood spots. For serum, the agreement of the LFA with the non-reference multiplex assay was 96%, the specificity using nonendemic pediatric sera was 100%, and the inter-rater agreement was κ=0.961. For whole blood, the agreement of LFA with multiplex was 81.5%, the specificity was 100%, and the inter-rater agreement was κ=0.940. The LFA was tested in a field environment and yielded similar results to those from laboratory-based testing. These data show the successful development of a lateral flow assay for detection of antibodies against Pgp3 with reliable use in field settings, which would make antibody-based testing for trachoma surveillance highly practical, especially after cessation of trachoma elimination programs. PMID:27208400

  16. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200...

  17. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200...

  18. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200...

  19. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200...

  20. Parametric Testing of Chevrons on Single Flow Hot Jets

    NASA Technical Reports Server (NTRS)

    Bridges, James; Brown, Clifford A.

    2004-01-01

    A parametric family of chevron nozzles have been studied, looking for relationships between chevron geometric parameters, flow characteristics, and far-field noise. Both cold and hot conditions have been run at acoustic Mach number 0.9. Ten models have been tested, varying chevron count, penetration, length, and chevron symmetry. Four comparative studies were defined from these datasets which show: that chevron length is not a major impact on either flow or sound; that chevron penetration increases noise at high frequency and lowers it at low frequency, especially for low chevron counts; that chevron count is a strong player with good low frequency reductions being achieved with high chevron count without strong high frequency penalty; and that chevron asymmetry slightly reduces the impact of the chevron. Finally, it is shown that although the hot jets differ systematically from the cold one, the overall trends with chevron parameters is the same.

  1. Testing of models of flow-induced hemolysis in blood flow through hypodermic needles.

    PubMed

    Chen, Yangsheng; Kent, Timothy L; Sharp, M Keith

    2013-03-01

    Hemolysis caused by flow in hypodermic needles interferes with a number of tests on blood samples drawn by venipuncture, including assays for metabolites, electrolytes, and enzymes, causes discomfort during dialysis sessions, and limits transfusion flow rates. To evaluate design modifications to address this problem, as well as hemolysis issues in other cardiovascular devices, computational fluid dynamics (CFD)-based prediction of hemolysis has potential for reducing the time and expense for testing of prototypes. In this project, three CFD-integrated blood damage models were applied to flow-induced hemolysis in 16-G needles and compared with experimental results, which demonstrated that a modified needle with chamfered entrance increased hemolysis, while a rounded entrance decreased hemolysis, compared with a standard needle with sharp entrance. After CFD simulation of the steady-state velocity field, the time histories of scalar stress along a grid of streamlines were calculated. A strain-based cell membrane failure model and two empirical power-law blood damage models were used to predict hemolysis on each streamline. Total hemolysis was calculated by weighting the predicted hemolysis along each streamline by the flow rate along each streamline. The results showed that only the strain-based blood damage model correctly predicted increased hemolysis in the beveled needle and decreased hemolysis in the rounded needle, while the power-law models predicted the opposite trends. PMID:23419169

  2. Flight Tests of a Supersonic Natural Laminar Flow Airfoil

    NASA Technical Reports Server (NTRS)

    Frederick, Mike; Banks, Dan; Garzon, Andres; Matisheck, Jason

    2014-01-01

    IR thermography was used to characterize the transition front on a S-NLF test article at chord Reynolds numbers in excess of 30 million Changes in transition due to Mach number, Reynolds number, and surface roughness were investigated - Regions of laminar flow in excess of 80% chord at chord Reynolds numbers greater than 14 million IR thermography clearly showed the transition front and other flow features such as shock waves impinging upon the surface A series of parallel oblique shocks, of yet unknown origin, were found to cause premature transition at higher Reynolds numbers. NASA has a current goal to eliminate barriers to the development of practical supersonic transport aircraft Drag reduction through the use of supersonic natural laminar flow (S-NLF) is currently being explored as a means of increasing aerodynamic efficiency - Tradeoffs work best for business jet class at M<2 Conventional high-speed designs minimize inviscid drag at the expense of viscous drag - Existence of strong spanwise pressure gradient leads to crossflow (CF) while adverse chordwise pressure gradients amplifies and Tollmien-Schlichting (TS) instabilities Aerion Corporation has patented a S-NLF wing design (US Patent No. 5322242) - Low sweep to control CF - dp/dx < 0 on both wing surfaces to stabilize TS - Thin wing with sharp leading edge to minimize wave drag increase due to reduction in sweep NASA and Aerion have partnered to study S-NLF since 1999 Series of S-NLF experiments flown on the NASA F-15B research test bed airplane Infrared (IR) thermography used to characterize transition - Non-intrusive, global, good spatial resolution - Captures significant flow features well

  3. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    SciTech Connect

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  4. Corrosion erosion test of SS316 in flowing Pb Bi

    NASA Astrophysics Data System (ADS)

    Kikuchi, K.; Kurata, Y.; Saito, S.; Futakawa, M.; Sasa, T.; Oigawa, H.; Wakai, E.; Miura, K.

    2003-05-01

    Corrosion tests of austenitic stainless tube were done under flowing Pb-Bi conditions for 3000 h at 450 °C. Specimens were 316SS produced as a tubing form with 13.8 mm outer diameter, 2 mm thickness and 40 cm length. During operation, maximum temperature, temperature difference and flow velocity of Pb-Bi at the specimen were kept at 450, 50 °C, and 1 m/s, respectively. After the test, specimen and components of the loop were cut and examined by optical microscope, SEM, EDX, WDX and X-ray diffraction. Pb-Bi adhered on the surface of the specimen even after Pb-Bi was drained out to the storage tank from the circulating loop. Results differed from a stagnant corrosion test in that the specimen surface became rough and the corrosion rate was maximally 0.1 mm/3000 h. Mass transfer from the high temperature to the lower temperature area was observed: crystals of Fe-Cr were found on the tube surface in the low-temperature region. The sizes of crystals varied from 0.1 to 0.2 mm. The depositing crystals were ferrite grains and the chemical composition ratio (mass%) of Fe to Cr was 9:1.

  5. 75 FR 77901 - 30-Day Notice of Opportunity for Public Comment on U.S. Nominations to the World Heritage List...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-14

    ... in the Federal Register on July 27, 2006 (FR 71, 144:42664-42665). The National Park Service Office... National Park Service 30-Day Notice of Opportunity for Public Comment on U.S. Nominations to the World Heritage List and Potential Additions to the U.S. World Heritage Tentative List AGENCY: National...

  6. Multiphase pumps and flow meters -- Status of field testing

    SciTech Connect

    Skiftesvik, P.K.; Svaeren, J.A.

    1995-12-31

    With the development and qualification of multiphase pumps and multiphase flow meters, two new tools have been made available to the oil and gas industry for enhanced production from existing installations or new field developments. This paper presents an overview of the major achievements gained from various test installations carried out the last years using equipment qualified by Framo Engineering AS. The experience from the extensive Field Verification Programmes as described shows that multiphase pumps and meters can operate in various and often harsh well environments providing significant well stream pressure boost or acceptable phase accuracy measurements of oil, water and gas.

  7. Uptake of a Consumer-Focused mHealth Application for the Assessment and Prevention of Heart Disease: The <30 Days Study

    PubMed Central

    Morita, Plinio P; Picton, Peter; Seto, Emily; Zbib, Ahmad; Cafazzo, Joseph A

    2016-01-01

    Background Lifestyle behavior modification can reduce the risk of cardiovascular disease, one of the leading causes of death worldwide, by up to 80%. We hypothesized that a dynamic risk assessment and behavior change tool delivered as a mobile app, hosted by a reputable nonprofit organization, would promote uptake among community members. We also predicted that the uptake would be influenced by incentives offered for downloading the mobile app. Objective The primary objective of our study was to evaluate the engagement levels of participants using the novel risk management app. The secondary aim was to assess the effect of incentives on the overall uptake and usage behaviors. Methods We publicly launched the app through the iTunes App Store and collected usage data over 5 months. Aggregate information included population-level data on download rates, use, risk factors, and user demographics. We used descriptive statistics to identify usage patterns, t tests, and analysis of variance to compare group means. Correlation and regression analyses determined the relationship between usage and demographic variables. Results We captured detailed mobile usage data from 69,952 users over a 5-month period, of whom 23,727 (33.92%) were registered during a 1-month AIR MILES promotion. Of those who completed the risk assessment, 73.92% (42,380/57,330) were female, and 59.38% (34,042/57,330) were <30 years old. While the older demographic had significantly lower uptake than the younger demographic, with only 8.97% of users aged ≥51 years old downloading the app, the older demographic completed more challenges than their younger counterparts (F 8, 52,422 = 55.10, P<.001). In terms of engagement levels, 84.94% (44,537/52,431) of users completed 1–14 challenges over a 30-day period, and 10.03% (5,259/52,431) of users completed >22 challenges. On average, users in the incentives group completed slightly more challenges during the first 30 days of the intervention (mean 7.9, SD 0

  8. The AFFORD Clinical Decision Aid To Identify Emergency Department Patients With Atrial Fibrillation At Low Risk For 30-Day Adverse Events

    PubMed Central

    Barrett, Tyler W.; Storrow, Alan B.; Jenkins, Cathy A.; Abraham, Robert L.; Liu, Dandan; Miller, Karen F.; Moser, Kelly M.; Russ, Stephan; Roden, Dan M.; Harrell, Frank E.; Darbar, Dawood

    2015-01-01

    There is wide variation in the management of emergency department (ED) patients with atrial fibrillation (AF). We aimed to derive and internally validate the first prospective, ED-based clinical decision aid to identify patients with AF at low risk for 30-day adverse events. We performed a prospective cohort study at a university-affiliated, tertiary-care, ED. Patients were enrolled from June 9, 2010 to February 28, 2013 and followed for 30 days. We enrolled a convenience sample of ED patients presenting with symptomatic AF. Candidate predictors were based on ED data available in the first two hours. The decision aid was derived using model approximation (preconditioning) followed by strong bootstrap internal validation. We utilized an ordinal outcome hierarchy defined as the incidence of the most severe adverse event within 30 days of the ED evaluation. Of 497 patients enrolled, stroke and AF-related death occurred in 13 (3%) and 4 (<1%) patients, respectively. The decision aid included the following: age, triage vitals (systolic blood pressure, temperature, respiratory rate, oxygen saturation, supplemental oxygen requirement); medical history (heart failure, home sotalol use, prior percutaneous coronary intervention, electrical cardioversion, cardiac ablation, frequency of AF symptoms); ED data (2 hour heart rate, chest radiograph results, hemoglobin, creatinine, and brain natriuretic peptide). The decision aid’s c-statistic in predicting any 30-day adverse event was 0.7 (95% CI, 0.65, 0.76). In conclusion, among ED patients with AF, AFFORD provides the first evidence based decision aid for identifying patients who are at low risk for 30-day adverse events and candidates for safe discharge. PMID:25633190

  9. Tropical 40-50- and 25-30-day oscillations appearing in realistic and idealized GFDL climate models and the ECMWF dataset

    SciTech Connect

    Hayashi, Y.; Golder, D.G. )

    1993-02-01

    To clarify differences between the tropical 40-50- and 25-30-day oscillations and to evaluate simulations and various theories, space-time spectrum and filter analyses were performed on a nine-year dataset taken from the nine-level R30 spectral general circulation model and the nine-year (1979-1987) ECMWF four-dimensional analysis dataset. The 40-level SKYHI model was analyzed to examine the effect of increased vertical resolution, while an ocean-surface perpetual January R30 model was analyzed to examine the effects of the absence of geographical and seasonal variations. The R30 model results indicate that the relative amplitude of the wavenumber-one component of the 40-50- and 25-30-day oscillations varies greatly from year to year. The SKYHI model indicates that 25-30-day oscillations still appear too strong, although this model reveals a longer vertical wavelength, a higher penetration of the 25-30-day amplitude above the level of convective heating, and a slightly greater height of the convective-heating amplitude, which cannot be detected in the R30 model. The ocean-surface perpetual January R30 model indicates that not only the 25-30-day mode but also the 40-50-day mode can be simulated in the absence of geographical and seasonal modulations, while the wave-CISK and evaporation-wind feedback theories cannot explain the 40-50-day mode. Both R30 models indicate that daily precipitation is usuallys associated with upward motion. A comparison between the two R30 models suggests that the sea surface temperature geographically modules the intrinsically eastward-moving wavenumber-one precipitation oscillations, resulting in their major Pacific and minor Atlantic local amplitudes. This causes planetary-scale eastward-moving zonal-velocity oscillations and standing geopotential oscillations. 121 refs., 26 figs.

  10. Compatibility tests of steels in flowing liquid lead-bismuth

    NASA Astrophysics Data System (ADS)

    Barbier, F.; Benamati, G.; Fazio, C.; Rusanov, A.

    2001-06-01

    The behaviour of steels exposed to flowing Pb-55Bi was evaluated. The materials tested are the two austenitic steels AISI 316L and 1.4970, and the six martensitic steels Optifer IVc, T91, Batman 27, Batman 28, EP823 and EM10 which were exposed to flowing Pb-55Bi for 1000, 2000 and 3000 h and at two temperatures (573 and 743 K). The corrosion tests were conducted in the non-isothermal loop of IPPE-Obninsk under a controlled oxygen level (10 -6 wt%). The compatibility study showed that at a lower temperature, a very thin oxide layer (<1 μm) was formed on the steels. At higher temperature, austenitic steels also exhibited a thin oxide layer sufficient to prevent their dissolution in the melt. A thicker oxide, which grew according to a parabolic law, was observed on the surface of the martensitic steels. The oxidation resistance behaviour of the martensitic steels was correlated with their alloying elements.

  11. Uninstrumented assembly airflow testing in the Annular Flow Distribution facility

    SciTech Connect

    Kielpinski, A.L.

    1992-02-01

    During the Emergency Cooling System phase of a postulated large-break loss of coolant accident (ECS-LOCA), air enters the primary loop and is pumped down the reactor assemblies. One of the experiments performed to support the analysis of this accident was the Annular Flow Distribution (AFD) experiment, conducted in a facility built for this purpose at Babcock and Wilcox Alliance Research Center in Alliance, Ohio. As part of this experiment, a large body of airflow data were acquired in a prototypical mockup of the Mark 22 reactor assembly. This assembly was known as the AFD (or the I-AFD here) reference assembly. The I-AFD assembly was fully prototypical, having been manufactured in SRS`s production fabrication facility. Similar Mark 22 mockup assemblies were tested in several test facilities in the SRS Heat Transfer Laboratory (HTL). Discrepancies were found. The present report documents further work done to address the discrepancy in airflow measurements between the AFD facility and HTL facilities. The primary purpose of this report is to disseminate the data from the U-AFD test, and to compare these test results to the I-AFD data and the U-AT data. A summary table of the test data and the B&W data transmittal letter are included as an attachment to this report. The full data transmittal volume from B&W (including time plots of the various instruments) is included as an appendix to this report. These data are further analyzed by comparing them to two other HTL tests, namely, SPRIHTE 1 and the Single Assembly Test Stand (SATS).

  12. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied by a constant-flow device only, the rate of flow shall be at least 3 liters per minute for the...

  13. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied by a constant-flow device only, the rate of flow shall be at least 3 liters per minute for the...

  14. 76 FR 28499 - 30-Day Notice of Proposed Information Collection: Form DS-6561, Pre-Assignment for Overseas Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    .... Estimated Number of Responses: 8,000 per year Average Hours per Response: 1 hour per response. Total..., lab tests and physical examination for employees and family members that are not members of one of...

  15. Laminar flow control leading edge glove flight test article development

    NASA Technical Reports Server (NTRS)

    Pearce, W. E.; Mcnay, D. E.; Thelander, J. A.

    1984-01-01

    A laminar flow control (LFC) flight test article was designed and fabricated to fit into the right leading edge of a JetStar aircraft. The article was designed to attach to the front spar and fill in approx. 70 inches of the leading edge that are normally occupied by the large slipper fuel tank. The outer contour of the test article was constrained to align with an external fairing aft of the front spar which provided a surface pressure distribution over the test region representative of an LFC airfoil. LFC is achieved by applying suction through a finely perforated surface, which removes a small fraction of the boundary layer. The LFC test article has a retractable high lift shield to protect the laminar surface from contamination by airborne debris during takeoff and low altitude operation. The shield is designed to intercept insects and other particles that could otherwise impact the leading edge. Because the shield will intercept freezing rain and ice, a oozing glycol ice protection system is installed on the shield leading edge. In addition to the shield, a liquid freezing point depressant can be sprayed on the back of the shield.

  16. Field Test of a DHW Distribution System: Temperature and Flow Analyses (Presentation)

    SciTech Connect

    Barley, C. D.; Hendron, B.; Magnusson, L.

    2010-05-13

    This presentation discusses a field test of a DHW distribution system in an occupied townhome. It includes measured fixture flows and temperatures, a tested recirculation system, evaluated disaggregation of flow by measured temperatures, Aquacraft Trace Wizard analysis, and comparison.

  17. The CD14 rs2569190 TT Genotype Is Associated with an Improved 30-Day Survival in Patients with Sepsis: A Prospective Observational Cohort Study

    PubMed Central

    Mansur, Ashham; Liese, Benjamin; Steinau, Maximilian; Ghadimi, Michael; Bergmann, Ingo; Tzvetkov, Mladen; Popov, Aron Frederik; Beissbarth, Tim; Bauer, Martin; Hinz, José

    2015-01-01

    According to previous investigations, CD14 is suggested to play a pivotal role in initiating and perpetuating the pro-inflammatory response during sepsis. A functional polymorphism within the CD14 gene, rs2569190, has been shown to impact the pro-inflammatory response upon stimulation with lipopolysaccharide, a central mediator of inflammation in sepsis. In this study, we hypothesized that the strong pro-inflammatory response induced by the TT genotype of CD14 rs2569190 may have a beneficial effect on survival (30-day) in patients with sepsis. A total of 417 adult patients with sepsis (and of western European descent) were enrolled into this observational study. Blood samples were collected for rs2569190 genotyping. Patients were followed over the course of their stay in the ICU, and the 30-day mortality risk was recorded as the primary outcome parameter. Sepsis-related organ failure assessment (SOFA) scores were quantified at sepsis onset and throughout the observational period to monitor organ failure as a secondary variable. Moreover, organ support-free days were evaluated as a secondary outcome parameter. TT-homozygous patients were compared to C-allele carriers. Kaplan-Meier survival analysis revealed a higher 30-day mortality risk among C-allele carriers compared with T homozygotes (p = 0.0261). To exclude the effect of potential confounders (age, gender, BMI and type of infection) and covariates that varied at baseline with a p-value < 0.2 (e.g., comorbidities), we performed multivariate Cox regression analysis to examine the survival time. The CD14 rs2569190 C allele remained a significant covariate for the 30-day mortality risk in the multivariate analysis (hazard ratio, 2.11; 95% CI, 1.08-4.12; p = 0.0282). The 30-day mortality rate among C allele carriers was 23%, whereas the T homozygotes had a mortality rate of 13%. Additionally, an analysis of organ-specific SOFA scores revealed a significantly higher SOFA-Central nervous system score among patients

  18. 30 CFR 75.152 - Tests of air flow; qualified person.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of air flow; qualified person. 75.152....152 Tests of air flow; qualified person. A person is a qualified person within the meaning of the provisions of Subpart D—Ventilation of this part requiring that tests of air flow be made by a...

  19. 30 CFR 75.152 - Tests of air flow; qualified person.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of air flow; qualified person. 75.152....152 Tests of air flow; qualified person. A person is a qualified person within the meaning of the provisions of Subpart D—Ventilation of this part requiring that tests of air flow be made by a...

  20. 30 CFR 75.152 - Tests of air flow; qualified person.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of air flow; qualified person. 75.152....152 Tests of air flow; qualified person. A person is a qualified person within the meaning of the provisions of Subpart D—Ventilation of this part requiring that tests of air flow be made by a...

  1. 30 CFR 75.152 - Tests of air flow; qualified person.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of air flow; qualified person. 75.152....152 Tests of air flow; qualified person. A person is a qualified person within the meaning of the provisions of Subpart D—Ventilation of this part requiring that tests of air flow be made by a...

  2. Aeroacoustic Characteristics of Model Jet Test Facility Flow Conditioners

    NASA Technical Reports Server (NTRS)

    Kinzie, Kevin W.; Henderson, Brenda S.; Haskin, Harry H.

    2005-01-01

    An experimental investigation of flow conditioning devices used to suppress internal rig noise in high speed, high temperature experimental jet facilities is discussed. The aerodynamic and acoustic characteristics of a number of devices including pressure loss and extraneous noise generation are measured. Both aerodynamic and acoustic characteristics are strongly dependent on the porosity of the flow conditioner and the closure ratio of the duct system. For unchoked flow conditioners, the pressure loss follows conventional incompressible flow models. However, for choked flow conditioners, a compressible flow model where the duct and flow conditioner system is modeled as a convergent-divergent nozzle can be used to estimate pressure loss. Choked flow conditioners generate significantly more noise than unchoked conditioners. In addition, flow conditioners with small hole diameters or sintered metal felt material generate less self-noise noise compared to flow conditioners with larger holes.

  3. Performance and mood-state parameters during 30-day 6 degrees head-down bed rest with exercise training

    NASA Technical Reports Server (NTRS)

    DeRoshia, C. W.; Greenleaf, J. E.

    1993-01-01

    The study was designed to determine if performance and mood impairments occur in bed-rested subjects, and if different exercise-training regimens modify or prevent them. Eighteen normal, healthy men were divided on the basis of age, peak oxygen uptake, and maximal isometric knee extension strength into three similar groups: no exercise (NOE), isotonic exercise (ITE), and isokinetic exercise (IKE). A 15-min battery of 10 performance tests and 8 mood and 2 sleep scales were administered daily during ambulatory control, 30 d of absolute bed rest (BR), and 4 d of ambulatory recovery. Performance test proficiency increased (p < 0.05) for all three groups during BR in 7 of 10 tests and there were no consistent significant differences between the three groups. However, during BR, the ITE group was distinguished from the other groups by a decline (p < 0.05) in the activation mood dimension and in two of its constituent scales (motivation and concentration), and by improvement (p < 0.05) in the trouble-falling-asleep and psychological-tension scales. Since few deleterious changes in performance and mood occurred in the three groups and did not exceed baseline ambulatory levels, we conclude that mood and performance did not deteriorate in response to prolonged BR and were not altered by exercise training. However, the decline in activation mood scales in the ITE group may reflect overtraining or excess total workload in this group.

  4. [STRUCTURAL-FUNCTIONAL STATUS OF THE LYMPH TISSUE OF MICE LYMPHATIC NODES FOLLOWING THE 30-DAY FLIGHT ONBOARD SPACECRAFT BION-M1].

    PubMed

    Bulekbaeva, L E; Demchenko, G A; Ilyin, E A; Erofeeva, L M

    2015-01-01

    The article reports the results of studying the lymph tissue of mesenteric and cervical lymphatic nodes in C57BL/6N mice after the 30-day orbital flight onboard biosatellite Bion-M1. Histological and morphometric investigations revealed changes in the ratio of the nodes structural-functional zones and microstructure. Reductions in reticular cells, plasmocytes, macrophages and blasts in the nodes point to degradation of both humoral and cellular immunity.

  5. Influence of second- and third-degree heart block on 30-day outcome following acute myocardial infarction in the drug-eluting stent era.

    PubMed

    Kim, Hack-Lyoung; Kim, Sang-Hyun; Seo, Jae-Bin; Chung, Woo-Young; Zo, Joo-Hee; Kim, Myung-A; Park, Kyung-Woo; Koo, Bon-Kwon; Kim, Hyo-Soo; Chae, In-Ho; Choi, Dong-Ju; Cho, Myeong-Chan; Kim, Young-Jo; Kim, Ju Han; Ahn, Youngkeun; Jeong, Myung Ho

    2014-12-01

    This study was conducted to investigate the prognostic value of heart block among patients with acute myocardial infarction (AMI) treated with drug-eluting stents. A total of 13,862 patients with AMI, registered in the nation-wide AMI database from January 2005 to June 2013, were analyzed. Second- (Mobitz type I or II) and third-degree atrioventricular block were considered as heart block in this study. Thirty-day major adverse cardiac events (MACE) including all causes of death, recurrent myocardial infarction, and revascularization were evaluated. Percutaneous coronary intervention with implantation of drug-eluting stent was performed in 89.8% of the patients. Heart block occurred in 378 patients (2.7%). Thirty-day MACE occurred in 1,144 patients (8.2%). Patients with heart block showed worse clinical parameters at initial admission, and the presence of heart block was associated with 30-day MACE in univariate analyses. However, the prognostic impact of heart block was not significant after adjustment of potential confounders (p = 0.489). Among patients with heart block, patients with a culprit in the left anterior descending (LAD) coronary artery had worse clinical outcomes than those of patients with a culprit in the left circumflex or right coronary artery. LAD culprit was a significant risk factor for 30-day MACE even after controlling for confounders (odds ratio 5.28, 95% confidence interval 1.22 to 22.81, p = 0.026). In conclusion, despite differences in clinical parameters at the initial admission, heart block was not an independent risk factor for 30-day MACE in adjusted analyses. However, a LAD culprit was an independent risk factor for 30-day MACE among patients with heart block.

  6. [STRUCTURAL-FUNCTIONAL STATUS OF THE LYMPH TISSUE OF MICE LYMPHATIC NODES FOLLOWING THE 30-DAY FLIGHT ONBOARD SPACECRAFT BION-M1].

    PubMed

    Bulekbaeva, L E; Demchenko, G A; Ilyin, E A; Erofeeva, L M

    2015-01-01

    The article reports the results of studying the lymph tissue of mesenteric and cervical lymphatic nodes in C57BL/6N mice after the 30-day orbital flight onboard biosatellite Bion-M1. Histological and morphometric investigations revealed changes in the ratio of the nodes structural-functional zones and microstructure. Reductions in reticular cells, plasmocytes, macrophages and blasts in the nodes point to degradation of both humoral and cellular immunity. PMID:26554128

  7. Laparoscopic sleeve gastrectomy at a new bariatric surgery centre in Canada: 30-day complication rates using the Clavien–Dindo classification

    PubMed Central

    Falk, Vanessa; Twells, Laurie; Gregory, Deborah; Murphy, Raleen; Smith, Chris; Boone, Darrell; Pace, David

    2016-01-01

    Background Newfoundland and Labrador (NL) has the highest rate of obesity in Canada, prompting the establishment of a bariatric surgery program at the Health Sciences Centre in NL. This retrospective study examined 30-day complication rates in more than 200 consecutive patients who underwent laparoscopic sleeve gastrectomy (LSG) between May 2011 and February 2014. Methods We performed a chart review and collected data on 30-day postoperative complications. Complications were graded and reported using the Clavien–Dindo classification. Grades I and II were defined as minor and grades III and higher were defined as major complications. Results We reviewed the charts of the first 209 patients to undergo LSG. The mean body mass index was 49.2, 81% were women and the average age was 43 years. Comorbidities included hypertension (55.0%), obstructive sleep apnea (46.4%), dyslipidemia (42.1%), diabetes (37.3%), osteoarthritis (36.4%) and cardiovascular disease with previous cardiac stents (5.3%). Furthermore, 38.3% of patients reported psychiatric diagnoses, such as depression and anxiety. The overall 30-day complication rate was 15.3%. The complication rate for minor complications was 13.4% and for major complications was 1.9% (2 leaks, 1 stricture and 1 fistula). Conclusion Our results support the feasibility of safely performing LSG surgery at bariatric centres completing fewer than 125 procedures annually. PMID:27007089

  8. Cinematics and sticking of heart valves in pulsatile flow test.

    PubMed

    Köhler, J; Wirtz, R

    1991-05-01

    The aim of the project was to develop laboratory test devices for studies of the cinematics and sticking behaviour of technical valve protheses. The second step includes testing technical valves of different types and sizes under static and dynamic conditions. A force-deflection balance was developed in order to load valve rims by static radial forces until sticking or loss of a disc (sticking- and clamping-mould point) with computer-controlled force deflection curves. A second deflection device was developed and used for prosthetic valves in the aortic position of a pulsatile mock circulation loop with simultaneous video-cinematography. The stiffness of technical valve rims varied between 0.20 (St. Jude) and about 1.0 N/micron (metal rim valves). The stiffness decreased significantly with increasing valve size. Sticking under pulsatile flow conditions was in good agreement with the static deflection measurements. Hence, valve sticking with increasing danger of thrombus formation is more likely with a less stiff valve rim. In the case of forces acting perpendicularly to the pendulum axis, the clamping mould-point of the valve can be reached, followed by disc dislodgement. PMID:1864654

  9. Supine Lower Body Negative Pressure Exercise Maintains Upright Exercise Capacity in Male Twins during 30 Days of Bed Rest

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Schneider, Suzanne M.; Boda, Wanda L.; Watenpaugh, Donald E.; Macias, Brandon R.; Meyer, R. Scott; Hargens, Alan R.

    2006-01-01

    Exercise capacity is reduced following both short and long duration exposures to microgravity. We have shown previously that supine lower body negative pressure with exercise (LBNP(sub ex) maintains upright exercise capacity in men after 5d and 15d bed rest, as a simulation of microgravity. We hypothesized that LBNP(sub ex) would protect upright exercise capacity (VO2pk) and sprint performance in eight sets of identical male twins during a 30-d bed rest. Twins within each set were randomly assigned to either a control group (CON) who performed no exercise or to an exercise group (EX) who performed a 40-min interval (40-80% pre-BR VO2pk) LBNP(sub ex) (55+/-4 mmHg) exercise protocol, plus 5 min of resting LBNP, 6 d/wk. LBNP produced footward force equivalent to 1.0- 1.2 times body weight. Pre- and post-bed rest, subjects completed an upright graded exercise test to volitional fatigue and sprint test of 30.5 m. After bed rest, VO2pk was maintained in the EX subjects (-3+/-3%), but was significantly decreased in the CON subjects (-24+/-4%). Sprint time also was increased in the CON subjects (24+/-8%), but maintained in the EX group (8+/-2%). The performance of a supine, interval exercise protocol with LBNP maintains upright exercise capacity and sprint performance during 30 d of bed rest. This exercise countermeasure protocol may help prevent microgravity-induced deconditioning during long duration space flight.

  10. Oscillatory Flow Testing in a Sandbox - Towards Oscillatory Hydraulic Tomography

    NASA Astrophysics Data System (ADS)

    Zhou, Y.; Lim, D.; Cupola, F.; Cardiff, M. A.

    2014-12-01

    Detailed knowledge of subsurface hydraulic properties is important for predicting groundwater flow and contaminant transport. The spatial variation of hydraulic properties in the shallow subsurface has been extensively studied in the past two decades. A recent approach to characterize subsurface properties is hydraulic tomography, in which pressure data from multiple constant-rate pumping tests is inverted using a numerical model. Many laboratory sandbox studies have explored the performance of hydraulic tomography under different controlled conditions and shown that detailed heterogeneity information can be extracted (Liu et al., 2002, Illman et al., 2007, 2008, 2010a, 2010b, Liu et al., 2007, 2008, Xiang et al., 2009, Yin and Illman, 2009, Liu and Kitanidis, 2011, Berg and Illman, 2011a). Recently, Cardiff et al. (2013) proposed a modified approach of Oscillatory Hydraulic Tomography (OHT) - in which periodic pumping signals of different frequencies are used for aquifer stimulation - to characterize aquifer properties. The potential advantages of OHT over traditional hydraulic tomography include: 1) no net injection or extraction of water; 2) little movement of existing contamination; 3) minimal impact of model boundary conditions; and 4) robust extraction of oscillatory signals from noisy data. To evaluate the premise of OHT, we built a highly-instrumented 2-D laboratory sandbox and record pressure responses to periodic pumping tests. In our setup, the laboratory sandbox is filled with sand of known hydraulic properties, and we measure aquifer responses at a variety of testing frequencies. The signals recorded are processed using Fourier-domain analysis, and compared against expected results under linear (Darcian) theory. The responses are analyzed using analytical and numerical models, which provide key insights as to: 1) how "effective" hydraulic properties estimated using homogeneous models are associated with aquifer heterogeneity; and 2) how OHT is able to

  11. Lower Extremity Muscle Thickness During 30-Day 6 degrees Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

    NASA Technical Reports Server (NTRS)

    Ellis, S.; Kirby, L. C.; Greenleaf, J. E.

    1993-01-01

    Muscle thickness was measured in 19 Bed-Rested (BR) men (32-42 year) subjected to IsoTonic (ITE, cycle orgometer) and IsoKi- netic (IKE, torque orgometer) lower extremity exercise training, and NO Exercise (NOE) training. Thickness was measured with ultrasonography in anterior thigh-Rectus Femoris (RF) and Vastus Intermadius (VI), and combined posterior log-soleus, flexor ballucis longus, and tibialis posterior (S + FHL +TP) - muscles. Compared with ambulatory control values, thickness of the (S + FHL + TP) decreased by 90%-12% (p less than 0.05) In all three test groups. The (RF) thickness was unchanged in the two exercise groups, but decreased by 10% (p less than 0.05) in the NOE. The (VI) thickness was unchanged In the ITE group, but decreased by 12%-l6% (p less than 0.05) in the IKE and NOE groups. Thus, intensive, alternating, isotonic cycle ergometer exercise training is as effective as intensive, intermittent, isokinetic exercise training for maintaining thicknesses of rectus femoris and vastus lntermedius anterior thigh muscles, but not posterior log muscles, during prolonged BR deconditioning.

  12. The sympathetic release test: a test used to assess thermoregulation and autonomic control of blood flow.

    PubMed

    Tansey, E A; Roe, S M; Johnson, C J

    2014-03-01

    When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the subject is gently heated by placing the feet and calves in a commercially available foot warming pouch or immersing the feet and calves in warm water and wrapping the subject in blankets. Skin blood flow is estimated from measurements of skin temperature in the fingers. Normally skin temperature of the fingers is 65-75°F in cool conditions (environmental temperature: 59-68°F) and rises to 85-95°F during body heating. Deviations in this pattern may mean that there is abnormal sympathetic vasoconstrictor control of skin blood flow. Abnormal skin blood flow can substantially impair an individual's ability to thermoregulate and has important clinical implications. During whole body heating, the skin temperature from three different skin sites is monitored and oral temperature is monitored as an index of core temperature. Students determine the fingertip temperature at which the reflex release of sympathetic activity occurs and its maximal attainment, which reflects the vasodilating capacity of this cutaneous vascular bed. Students should interpret typical sample data for certain clinical conditions (Raynaud's disease, peripheral vascular disease, and postsympathectomy) and explain why there may be altered skin blood flow in these disorders.

  13. Extended range (10-30 days) heavy rain forecasting study based on a nonlinear cross-prediction error model

    NASA Astrophysics Data System (ADS)

    Xia, Zhiye; Chen, Hongbin; Xu, Lisheng; Wang, Yongqian

    2015-12-01

    Extended range (10-30 d) heavy rain forecasting is difficult but performs an important function in disaster prevention and mitigation. In this paper, a nonlinear cross prediction error (NCPE) algorithm that combines nonlinear dynamics and statistical methods is proposed. The method is based on phase space reconstruction of chaotic single-variable time series of precipitable water and is tested in 100 global cases of heavy rain. First, nonlinear relative dynamic error for local attractor pairs is calculated at different stages of the heavy rain process, after which the local change characteristics of the attractors are analyzed. Second, the eigen-peak is defined as a prediction indicator based on an error threshold of about 1.5, and is then used to analyze the forecasting validity period. The results reveal that the prediction indicator features regarded as eigenpeaks for heavy rain extreme weather are all reflected consistently, without failure, based on the NCPE model; the prediction validity periods for 1-2 d, 3-9 d and 10-30 d are 4, 22 and 74 cases, respectively, without false alarm or omission. The NCPE model developed allows accurate forecasting of heavy rain over an extended range of 10-30 d and has the potential to be used to explore the mechanisms involved in the development of heavy rain according to a segmentation scale. This novel method provides new insights into extended range forecasting and atmospheric predictability, and also allows the creation of multi-variable chaotic extreme weather prediction models based on high spatiotemporal resolution data.

  14. Knee-joint proprioception during 30-day 6 degrees head-down bed rest with isotonic and isokinetic exercise training

    NASA Technical Reports Server (NTRS)

    Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.

    1994-01-01

    To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

  15. Knee-Joint Proprioception During 30-Day 6 deg Head-Down Bed Rest with Isotonic and Isokinetic Exercise Training

    NASA Technical Reports Server (NTRS)

    Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.

    1994-01-01

    To determine if daily isotonic exercise or isokinetic exercise training coupled with daily log proprioceptive training, would influence log proprioceptive tracking responses during Bed Rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a NO-Exercise (NOE) training control group (n = 5), and IsoTanic Exercise (ITE, n = 7) and IsoKinetic Exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min period / d, 5 d /week. Only the IKE group performed proprioceptive training using a now isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pro-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p less than 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9 +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.50, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both lsotonic exercise training (without additional propriaceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.

  16. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand...

  17. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand...

  18. 7 CFR 28.603 - Procedures for air flow tests of micronaire reading.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Procedures for air flow tests of micronaire reading... of the United States for Fiber Fineness and Maturity § 28.603 Procedures for air flow tests of...) Air flow instrument complete with accessories to measure the fineness and maturity, in combination,...

  19. Oscillating-flow loss test results in rectangular heat exchanger passages

    NASA Technical Reports Server (NTRS)

    Wood, J. Gary

    1991-01-01

    Test results of oscillating flow losses in rectangular heat exchanger passages of various aspect ratios are given. This work was performed in support of the design of a free-piston Stirling engine (FPSE) for a dynamic space power conversion system. Oscillating flow loss testing was performed using an oscillating flow rig, which was based on a variable stroke and variable frequency linear drive motor. Tests were run over a range of oscillating flow parameters encompassing the flow regimes of the proposed engine design. Test results are presented in both tabular and graphical form and are compared against analytical predictions.

  20. EFFECTS OF TEST TEMPERATURE ON FLOW OF METALLIC GLASSES

    SciTech Connect

    A.S. NOURI; Y. LIU; P. WESSELING; J. LEWANDOWSKI

    2006-04-12

    Micro-hardness experiments were conducted over a range of temperatures using a Nikon QM micro-hardness machine on a number of metallic glass (e.g. Zr-, Fe-, Al-) systems. Although high micro-hardness was exhibited at room temperature, significant hardness reductions were exhibited near the glass transition temperature, T{sub g}. The effects of changes in test temperature on the micro-hardness will be reported. The effects of exposure time on the hardness evolution at a given temperature will also be summarized to illustrate some of the differences in behavior of the systems shown. The extreme softening near T{sub g}, characteristic of bulk metallic glass systems, enables the exploration of novel deformation processing. In order to develop deformation processing windows, the evaluation of bulk metallic glass mechanical properties under quasi-static conditions and the determination of flow properties at different temperatures and strain rates are reported. The use of such information to create layered/composite bulk metallic glasses will be summarized.

  1. Repeat Procedures Within 30 days in Patients Stented for Malignant Distal Biliary Strictures: Experience of 508 Patients at a Tertiary Referral Center

    PubMed Central

    Byrne, Michael F; Chan, Calvin HY; Branch, Malcolm S; Jowell, Paul S; Baillie, John

    2012-01-01

    Background Stent related occlusion and migration remains a problem despite attempts to improve stent design over this time period. Flanged polyethylene plastic stents (FPS) remains the stent of choice in most centers. Early failure of stents placed for malignant extrahepatic biliary strictures (MEBS) has not previously been studied in detail. We set out to determine the incidence and reasons for biliary stent change within 30 days of the index procedure in a large tertiary center population during a period where (FPS) was the sole plastic stent used. Methods Retrospective analysis of endoscopic retrograde cholangiography (ERCP) was undertaken in patients who were stented for presumed or known MEBS between 1993 and 2001. Patients who required repeat stenting within 30 days were identified. Results All 508 patients were stented for MEBS. 5.7% of patients had a total of 34 repeat stenting procedures within 30 days of the index procedure; 27of 29 index stents were plastic, 2 were self-expandable metal stents (SEMS), 20 (3.9%) patients had stent failure as the reason for a stent exchange (plastic stent occlusion n = 15, mean time to stent change 14 ± 8.3 days; metal stent occlusion n = 2, mean time to stent change 24.5 ± 7.8 days; plastic stent migration n = 3, mean time to stent change 25 ± 5.3 days). There was a statistically significant difference in the time to stent change between the occluded plastic stent and migrated plastic stent cases (P = 0.045, 95% CI -21.7 to -0.29). 6 patients spent at least 2 additional days in hospital as a result of stent failure. Conclusions Early stent failure is an uncommon problem, especially in patients with SEMS. Early plastic stent failure appears to occur sooner with stent occlusion than with stent migration. Early stent failure is associated with significant morbidity and bears an economic impact in additional procedures and hospital stay.

  2. Quality measures for total ankle replacement, 30-day readmission and reoperation rates within 1 year of surgery: a data linkage study using the NJR data set

    PubMed Central

    Zaidi, Razi; Macgregor, Alexander J; Goldberg, Andy

    2016-01-01

    Objective To report on the rate of 30-day readmission and the rate of additional or revision surgery within 12 months following total ankle replacement (TAR). Design A data-linkage study of the UK National Joint Registry (NJR) data and Hospital Episodes Statistics (HES) database. These two databases were linked in a deterministic fashion. HES episodes 12 months following the index procedure were isolated and analysed. Logistic regression was used to model predictors of reoperation and revision for primary ankle replacement. Participants All patients who underwent primary and revision ankle replacements according to the NJR between February 2008 and February 2013. Results The rate of 30-day readmission following primary and revision ankle replacement was 2.2% and 1.3%, respectively. In the 12 months following primary and revision ankle replacements, the revision rate (where implants needed to be removed) was 1.2% with increased odds in those orthopaedic units preforming <20 ankle replacements per year and patients with a preoperative fixed equinus deformity. The reoperation other than revision (where implants were not removed) in the 12 months following primary and revision TARs was 6.6% and 9.3%, respectively. Rheumatoid arthritis, cemented prosthesis and high ASA grade significantly increased the odds of reoperation. Conclusions TAR has a 30-day readmission rate of 2.2%, which is similar to that of knee replacement but lower than that of total hip replacement. 6.6% of patients undergoing primary TAR require a reoperation within 12 months of the index procedure. Early revision rates are significantly higher in low-volume centres. PMID:27217286

  3. Length of stay, wait time to surgery and 30-day mortality for patients with hip fractures after the opening of a dedicated orthopedic weekend trauma room

    PubMed Central

    Taylor, Michel; Hopman, Wilma; Yach, Jeff

    2016-01-01

    Background In September 2011, Kingston General Hospital (KGH) opened a dedicated orthopedic weekend trauma room. Previously, 1 weekend operating room (OR) was used by all surgical services. We assessed the impact this dedicated weekend trauma room had on hospital length of stay (LOS), time to surgery and 30-day mortality for patients with hip fractures. Methods Patients admitted between Oct. 1, 2009, and Sept. 30, 2012, were identified through our trauma registry, representing the 2 years before and 1 year after the opening of the orthopedic weekend trauma room. We documented type of fracture, mode of fixation, age, sex, American Society of Anesthesiologists (ASA) score, time to OR, LOS, discharge disposition and 30-day mortality. We excluded patients with multiple fractures, open fractures and those requiring trauma team activation. Results Our study included 609 patients (405 pre- and 204 post–trauma room opening). Mean LOS decreased from 11.6 to 9.4 days (p = 0.005) and there was a decreasing trend in mean time to OR from 31.5 to 28.5 hours (p = 0.16). There was no difference in 30-day mortality (p = 0.24). The LOS decreased by an average of 2 days following opening of the weekend trauma room (p = 0.031) and by an average of 2.2 additional days if the patient was admitted on the weekend versus during the week (p = 0.024). Conclusion The weekend trauma OR at KGH significantly decreased the LOS and appears to have decreased wait times to surgery. Further analysis is needed to assess the cost-effectiveness of the current strategy, the long-term outcome of this patient population and the impact the additional orthopedic weekend trauma room has had on other surgical services (i.e., general surgery) and their patients. PMID:27668332

  4. Effectiveness of using thyrocalcitonin for the prevention of a calcium metabolic disorder in the mineralized tissues of rabbits with 30 days hypokinesia

    NASA Technical Reports Server (NTRS)

    Volozhin, A. I.; Shashkov, V. S.; Dmitriyev, B. S.; Yegorov, B. B.; Lobachik, V. I.; Brishin, A. I.

    1980-01-01

    A 30 day hypokinesia in rabbits led to a considerable lag in weight gain for the skeletal bones, reduction in Ca45 uptake, and an increase in isotope resorption rate in the rapidly metabolized fraction of extremity bones. On the other hand, Ca45 content in the teeth and maxillae increased, which may be explained by redistribution of isotope among the various mineralized tissues. Injection of thyrocalcitonin (50 IU/day) produced a distinct normalizing effect on Ca45 uptake and resorption in the mineralized tissues of rabbits kept hypokinetic.

  5. Life sciences payload definition and integration study. Volume 4: Appendix, costs, and data management requirements of the dedicated 30-day laboratory. [carry-on laboratory for Spacelab

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The results of the updated 30-day life sciences dedicated laboratory scheduling and costing activities are documented, and the 'low cost' methodology used to establish individual equipment item costs is explained in terms of its allowances for equipment that is commerical off-the-shelf, modified commercial, and laboratory prototype; a method which significantly lowers program costs. The costs generated include estimates for non-recurring development, recurring production, and recurring operations costs. A cost for a biomedical emphasis laboratory and a Delta cost to provide a bioscience and technology laboratory were also generated. All cost reported are commensurate with the design and schedule definitions available.

  6. F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment

    NASA Technical Reports Server (NTRS)

    Anders, Scott G.; Fischer, Michael C.

    1999-01-01

    The F-16XL-2 Supersonic Laminar Flow Control Flight Test Experiment was part of the NASA High-Speed Research Program. The goal of the experiment was to demonstrate extensive laminar flow, to validate computational fluid dynamics (CFD) codes and design methodology, and to establish laminar flow control design criteria. Topics include the flight test hardware and design, airplane modification, the pressure and suction distributions achieved, the laminar flow achieved, and the data analysis and code correlation.

  7. North vs south differences in acute peptic ulcer hemorrhage in Croatia: hospitalization incidence trends, clinical features, and 30-day case fatality

    PubMed Central

    Ljubičić, Neven; Pavić, Tajana; Budimir, Ivan; Puljiz, Željko; Bišćanin, Alen; Bratanić, Andre; Nikolić, Marko; Hrabar, Davor; Troskot, Branko

    2014-01-01

    Aim To assess the seven-year trends of hospitalization incidence due to acute peptic ulcer hemorrhage (APUH) and associated risk factors, and examine the differences in these trends between two regions in Croatia. Methods The study collected sociodemographic, clinical, and endoscopic data on 2204 patients with endoscopically confirmed APUH who were admitted to the Clinical Hospital Center “Sestre Milosrdnice,” Zagreb and Clinical Hospital Center Split between January 1, 2005 and December 31, 2011. We determined hospitalization incidence rates, 30-day case fatality rate, clinical outcomes, and incidence-associated factors. Results No differences were observed in APUH hospitalization incidence rates between the regions. Age-standardized one-year cumulative APUH hospitalization incidence rate calculated using the European Standard Population was significantly higher in Zagreb than in Split region (43.2/100 000 vs 29.2/100,000). A significantly higher APUH hospitalization incidence rates were observed in the above 65 years age group. Overall 30-day case fatality rate was 4.9%. Conclusion The hospitalization incidence of APUH in two populations did not change over the observational period and it was significantly higher in the Zagreb region. The incidence of acute duodenal ulcer hemorrhage also remained unchanged, whereas the incidence of acute gastric ulcer hemorrhage increased. The results of this study allow us to monitor epidemiological indicators of APUH and compare data with other countries. PMID:25559836

  8. Smart licensing and environmental flows: Modeling framework and sensitivity testing

    NASA Astrophysics Data System (ADS)

    Wilby, R. L.; Fenn, C. R.; Wood, P. J.; Timlett, R.; Lequesne, T.

    2011-12-01

    Adapting to climate change is just one among many challenges facing river managers. The response will involve balancing the long-term water demands of society with the changing needs of the environment in sustainable and cost effective ways. This paper describes a modeling framework for evaluating the sensitivity of low river flows to different configurations of abstraction licensing under both historical climate variability and expected climate change. A rainfall-runoff model is used to quantify trade-offs among environmental flow (e-flow) requirements, potential surface and groundwater abstraction volumes, and the frequency of harmful low-flow conditions. Using the River Itchen in southern England as a case study it is shown that the abstraction volume is more sensitive to uncertainty in the regional climate change projection than to the e-flow target. It is also found that "smarter" licensing arrangements (involving a mix of hands off flows and "rising block" abstraction rules) could achieve e-flow targets more frequently than conventional seasonal abstraction limits, with only modest reductions in average annual yield, even under a hotter, drier climate change scenario.

  9. The application of flow cytometry to histocompatibility testing.

    PubMed

    Horsburgh, T; Martin, S; Robson, A J

    2000-03-01

    Flow cytometry is a powerful technique that enables the sensitive and quantitative detection of both cellular antigens and bound biological moieties. This article reviews how flow cytometry is increasingly being used as histocompatibility laboratories for the analysis of antibody specificity and HLA antigen expression. A basic description of flow cytometry principles and standardisation is given, together with an outline of clinical application in the areas of pre-transplant cross-matching, antibody screening, post-transplant antibody monitoring and HLA-B27 detection. It is concluded that flow cytometry is a useful multi-parametric analytical tool, yielding clinical benefit especially in the identification of patients at risk of early transplant rejection. PMID:10834606

  10. Columbia University flow instability experimental program: Volume 3. Single tube parallel flow tests

    SciTech Connect

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1990-06-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1--2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. A series of down flow experiments have been conducted on three different size single tubes. The objective of these experiments was to determine the effect of a parallel flow path on the occurrence of flow instability. In all cases, it has been shown that the point of flow instability (OFI) determined under controlled flow operation does not change when operating in a controlled pressure drop mode (parallel path operation).

  11. Identification of a nonlinear groundwater flow at a slug test in fractured rock and its influence on the test

    NASA Astrophysics Data System (ADS)

    Ji, S.; Koh, Y.

    2013-12-01

    Many laboratory and numerical studies reported that a groundwater flow through a fracture at sufficiently high Reynolds numbers does not obey the cubic law which assumes a linear relation between the hydraulic gradient and the flux. Most of them observed that the transitions from a linear to nonlinear flow arose at the Reynolds numbers greater than 10. A slug test is one of the common hydraulic tests, and used for estimation of the hydraulic properties of an aquifer by analyzing the recovery after a sudden change in hydraulic pressure. In this study, we conducted a series of slug tests with various initial head displacements at an experimental borehole at KAERI's (Korea Atomic Energy Research Institute) underground research tunnel whose host rock is Jurassic granite. The Reynolds number at a fracture during slug tests was calculated using the geophysical logging data and slug test results, and the nonlinear flow regime at slug tests was identified. From changes in the Reynolds number during the tests and estimates of the hydraulic properties from the tests, the influence of a nonlinear flow on a slug test was discussed. Our results indicate that the nonlinearity of groundwater flow at a slug test became more severe and the estimated hydraulic conductivity decreased as the initial head displacement increased.

  12. Testing and Performance Verification of a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

    NASA Technical Reports Server (NTRS)

    VanZante, Dale E.; Podboy, Gary G.; Miller, Christopher J.; Thorp, Scott A.

    2009-01-01

    A 1/5 scale model rotor representative of a current technology, high bypass ratio, turbofan engine was installed and tested in the W8 single-stage, high-speed, compressor test facility at NASA Glenn Research Center (GRC). The same fan rotor was tested previously in the GRC 9x15 Low Speed Wind Tunnel as a fan module consisting of the rotor and outlet guide vanes mounted in a flight-like nacelle. The W8 test verified that the aerodynamic performance and detailed flow field of the rotor as installed in W8 were representative of the wind tunnel fan module installation. Modifications to W8 were necessary to ensure that this internal flow facility would have a flow field at the test package that is representative of flow conditions in the wind tunnel installation. Inlet flow conditioning was designed and installed in W8 to lower the fan face turbulence intensity to less than 1.0 percent in order to better match the wind tunnel operating environment. Also, inlet bleed was added to thin the casing boundary layer to be more representative of a flight nacelle boundary layer. On the 100 percent speed operating line the fan pressure rise and mass flow rate agreed with the wind tunnel data to within 1 percent. Detailed hot film surveys of the inlet flow, inlet boundary layer and fan exit flow were compared to results from the wind tunnel. The effect of inlet casing boundary layer thickness on fan performance was quantified. Challenges and lessons learned from testing this high flow, low static pressure rise fan in an internal flow facility are discussed.

  13. Operational evaluation of a proppeller test stand in the quiet flow facility at Langley Research Center

    NASA Technical Reports Server (NTRS)

    Block, P. J. W.

    1982-01-01

    Operational proof tests of a propeller test stand (PTS) in a quiet flow facility (QFF) are presented. The PTS is an experimental test bed for acoustic propeller research in the quiet flow environment of the QFF. These proof tests validate thrust and torque predictions, examine the repeatability of measurements on the PTS, and determine the effect of applying artificial roughness to the propeller blades. Since a thrusting propeller causes an open jet to contract, the potential flow core was surveyed to examine the magnitude of the contraction. These measurements are compared with predicted values. The predictions are used to determine operational limitations for testing a given propeller design in the QFF.

  14. Experimental testing of flexible barriers for containment of debris flows

    USGS Publications Warehouse

    DeNatale, Jay S.; Iverson, Richard M.; Major, Jon J.; LaHusen, Richard G.; Fliegel, Gregg L.; Duffy, John D.

    1999-01-01

    In June 1996, six experiments conducted at the U.S. Geological Survey Debris Flow Flume demonstrated that flexible, vertical barriers constructed of wire rope netting can stop small debris flows. All experimental debris flows consisted of water-saturated gravelly sand with less than two percent finer sediment by weight. All debris flows had volumes of about 10 cubic meters, masses of about 20 metre tons, and impact velocities of 5 to 9 meters per second. In four experiments, the debris flow impacted pristine, unreformed barriers of varying design; in the other two experiments, the debris flow impacted barriers already loaded with sediment from a previous flow. Differences in barrier design led to differences in barrier performance. Experiments were conducted with barriers constructed of square-mesh wire-rope netting with 30centimeter, 20centimeter, and 15 centimeter mesh openings as well as 30centimeter diameter interlocking steel rings. In all cases, sediment cascading downslope at the leading edge of the debris flows tended to spray through the nets. Nets fitted with finer-mesh chain link or chicken wire liners contained more sediment than did unlined nets, and a ring net fitted with a synthetic silt screen liner contained nearly 100 percent of the sediment. Irreversible net displacements of up to 2 meters and friction brake engagement on the support and anchor cables dissipated some of the impact energy. However, substantial forces developed in the steel support columns and the lateral and tie-back anchor cables attached to these columns. As predicted by elementary mechanics, the anchor cables experienced larger tensile forces when the support columns were hinged at the base rather than bolted rigidly to the foundation. Measured loads in the lateral anchor cables exceeded those in the tie-back anchor cables and the load cell capacity of 45 kilo-Newtons. Measurements also indicated that the peak loads in the tie- back anchors were highly transient and occurred at

  15. Characteristics and preliminary observations of the influence of electromyostimulation on the size and function of human skeletal muscle during 30 days of simulated microgravity

    NASA Technical Reports Server (NTRS)

    Duvoisin, Marc R.; Convertino, Victor A.; Buchanan, Paul; Gollnick, Philip A.; Dudley, Gary A.

    1989-01-01

    The effect of transcutaneous electromyostimulation (EMS) on the development of atrophy and the loss of strength in lower limb musculature in humans exposed to microgravity was determined in three subjects who received EMS twice daily in a 3-d on/1-d off cycle on their dominant leg during 30 days of bedrest. The output waveform from the stimulator was sequenced to the knee extensors, knee flexors, ankle extensors, and ankle flexors, and caused three isometric contractions of each muscle group per minute. It was found that, in the dominant leg, EMS acted to attenuate the changes caused by bedrest, such as reductions in the leg volume, muscle compartment size, cross-sectional area of slow- and fast-twitch fibers, strength, and aerobic enzyme activities, and an increase in leg compliance.

  16. 30 CFR 75.152 - Tests of air flow; qualified person.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests of air flow; qualified person. 75.152 Section 75.152 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Qualified and Certified Persons § 75.152 Tests of air flow; qualified person....

  17. Exposure to microgravity for 30 days onboard Bion M1 caused muscle atrophy and decreased regeneration in the mouse femoral Quadriceps

    NASA Astrophysics Data System (ADS)

    Grigoryan, Eleonora; Radugina, Elena A.; Almeida, Eduardo; Blaber, Elizabeth; Poplinskaya, Valentina; Markitantova, Yulia

    Mechanical unloading of muscle during spaceflight in microgravity is known to cause muscular atrophy, changes in muscle fiber type composition, gene expression, and reductions in regenerative muscle growth. Although limited data exists for long-term effects of microgravity in human muscle, these processes have mostly been studied in rodents for short periods of time, up to two weeks of spaceflight. Here we report on how 30-day, long-term, mechanical unloading in microgravity affects mouse muscle of the femoral Quadriceps group. To conduct these studies we used muscle tissue from 6 mice from the NASA Biospecimen Sharing Program conducted in collaboration with the Institute for Biomedical Problems of the Russian Academy of Sciences, during the Russian Bion M1 biosatellite mission in 2013. Muscle morphology observed in histological sections shows signs of extensive atrophy and regenerative hypoplasia. Specifically, we observed a two-fold decrease in the number of myonuclei and low density of myofibrils, their separation and fragmentation. Despite obvious atrophy, muscle regeneration nevertheless appears to have continued after 30 days in microgravity as evidenced by thin and short newly formed muscle fibers. Many of them however showed evidence of apoptosis and degradation of synthesized fibrils, suggesting long-term unloading in microgravity affects late stages of myofiber differentiation. Ground asynchronous and vivarium control animals showed normal, well-developed tissue structure with sufficient blood and nerve supply and evidence of regenerative formation of new muscle fibers free of apoptotic nuclei. Myofiber nuclei stress responses in spaceflight animals was detected by positive nuclear immunolocalization of c-jun and c-myc proteins. Regenerative activity of satellite cells in muscle was localized with pax-7, MyoD and MCad immunostaining, and did not appear altered in microgravity. In summary, long-term spaceflight in microgravity causes significant atrophy

  18. The effect of interactions between dietary egg white protein and zinc on body weight, bone growth and tissue trace metals in the 30-day-old rat.

    PubMed

    Wallwork, J C; Johnson, L K; Milne, D B; Sandstead, H H

    1983-07-01

    Nine groups of 30-day-old rats were fed different diets, which contained 8, 15 or 20% egg white (equivalent to 6.0, 11.3 and 15.0% protein, respectively) each at 3 levels of zinc (6, 12 and 18 ppm zinc) for 30 days. The rats consuming the 6.0% protein, regardless of zinc intake, gained less weight than the groups fed 11.3 or 15.0% protein. Plasma zinc was not influenced by dietary egg white protein content, whereas, plasma zinc levels were lower in the rats fed 6 ppm dietary zinc compared to those fed 12 or 18 ppm zinc. Of the liver trace metals measured, only iron appeared to be influenced by an egg white protein-zinc interaction. Increasing dietary egg white protein led to increased concentrations of liver zinc and magnesium. Dietary zinc levels had no effect on the concentration of these metals in the liver. Liver calcium and copper concentrations were not significantly influenced by either dietary zinc or egg white protein. Femur weights and lengths were lower in the rats fed 6.0% than in those fed 11.3 or 15.0% protein diet but were unaffected by dietary zinc. Femur width was related to dietary protein and zinc. Dietary protein and zinc were interrelated in their affect on femur zinc levels. Femur zinc concentrations increased with increasing dietary zinc levels. Also femur zinc levels decreased with increasing dietary protein content. Other femur metal (copper, iron and calcium) concentrations were higher in rats fed the low level versus the higher levels of protein, but were not influenced by dietary zinc. These results show that dietary zinc and egg white protein are interrelated with regard to their effect on body and femur growth and tissue trace metal content.

  19. Immunotoxicological Evaluation of Corn Genetically Modified with Bacillus thuringiensis Cry1Ah Gene by a 30-Day Feeding Study in BALB/c Mice

    PubMed Central

    Song, Yan; Liang, Chunlai; Wang, Wei; Fang, Jin; Sun, Nana; Jia, Xudong; Li, Ning

    2014-01-01

    This study was to investigate the immunotoxicological potential of corn genetically modified (GM) with Bacillus thuringiensis (Bt) Cry1Ah gene in BALB/c mice. Female BALB/c mice were randomly assigned to one of the four groups: the negative control group, the parental corn group, the GM corn group and the positive control group with 10 mice per group. Mice in the GM corn group and the parental corn group were fed with diets containing 70% corresponding corn for 30 days. Mice in the negative control group and the positive control group were fed with AIN93G diet, administered with saline or 200 mg/kg of cyclophosphamide (CY) via intraperitoneal injection 24 h before the termination of the study, respectively. At the end of the study, the immunotoxicological effects of the GM corn were evaluated through immunopathology parameters including body and organ weights, hematology and clinical chemistry parameters, histological examination, peripheral blood lymphocytes phenotype; humoral immunity including antibody plaque-forming cell, serum immunoglobulin, cytokine and half hemolysis value; cellular immunity such as mitogen-induced splenocyte proliferation, cytotoxic T-lymphocyte reaction, delayed-type hypersensitivity reaction; non-specific immunity including phagocytic activities of phagocytes, natural killer cell activity. A single dose of cyclophosphamide (200 mg/kg bw) was found to have significant adverse effects on immunopathology, cellular immunity, and humoral immunity in mice. The corn genetically modified with Bt Cry1Ah gene is considered consistent with the parental corn in terms of immunopathology, humoral immunity, cellular immunity and non-specific immunity. No adverse immunotoxicological effects of GM corn with Bt Cry1Ah gene were found when feeding mice for 30 days. PMID:24520311

  20. Immunotoxicological evaluation of corn genetically modified with Bacillus thuringiensis Cry1Ah gene by a 30-day feeding study in BALB/c mice.

    PubMed

    Song, Yan; Liang, Chunlai; Wang, Wei; Fang, Jin; Sun, Nana; Jia, Xudong; Li, Ning

    2014-01-01

    This study was to investigate the immunotoxicological potential of corn genetically modified (GM) with Bacillus thuringiensis (Bt) Cry1Ah gene in BALB/c mice. Female BALB/c mice were randomly assigned to one of the four groups: the negative control group, the parental corn group, the GM corn group and the positive control group with 10 mice per group. Mice in the GM corn group and the parental corn group were fed with diets containing 70% corresponding corn for 30 days. Mice in the negative control group and the positive control group were fed with AIN93G diet, administered with saline or 200 mg/kg of cyclophosphamide (CY) via intraperitoneal injection 24 h before the termination of the study, respectively. At the end of the study, the immunotoxicological effects of the GM corn were evaluated through immunopathology parameters including body and organ weights, hematology and clinical chemistry parameters, histological examination, peripheral blood lymphocytes phenotype; humoral immunity including antibody plaque-forming cell, serum immunoglobulin, cytokine and half hemolysis value; cellular immunity such as mitogen-induced splenocyte proliferation, cytotoxic T-lymphocyte reaction, delayed-type hypersensitivity reaction; non-specific immunity including phagocytic activities of phagocytes, natural killer cell activity. A single dose of cyclophosphamide (200 mg/kg bw) was found to have significant adverse effects on immunopathology, cellular immunity, and humoral immunity in mice. The corn genetically modified with Bt Cry1Ah gene is considered consistent with the parental corn in terms of immunopathology, humoral immunity, cellular immunity and non-specific immunity. No adverse immunotoxicological effects of GM corn with Bt Cry1Ah gene were found when feeding mice for 30 days.

  1. Development, testing and application of DrainFlow: A fully distributed integrated surface-subsurface flow model for drainage study

    NASA Astrophysics Data System (ADS)

    Shokri, Ali; Bardsley, William Earl

    2016-06-01

    Hydrological and hydrogeological investigation of drained land is a complex and integrated procedure. The scale of drainage studies may vary from a high-resolution small scale project through to comprehensive catchment or regional scale investigations. This wide range of scales and integrated system behaviour poses a significant challenge for the development of suitable drainage models. Toward meeting these requirements, a fully distributed coupled surface-subsurface flow model titled DrainFlow has been developed and is described. DrainFlow includes both the diffusive wave equation for surface flow components (overland flow, open drain, tile drain) and Richard's equation for saturated/unsaturated zones. To overcome the non-linearity problem created from switching between wet and dry boundaries, a smooth transitioning technique is introduced to buffer the model at tile drains and at interfaces between surface and subsurface flow boundaries. This gives a continuous transition between Dirichlet and Neumann boundary conditions. DrainFlow is tested against five well-known integrated surface-subsurface flow benchmarks. DrainFlow as applied to some synthetic drainage study examples is quite flexible for changing all or part of the model dimensions as required by problem complexity, problem scale, and data availability. This flexibility enables DrainFlow to be modified to allow for changes in both scale and boundary conditions, as often encountered in real-world drainage studies. Compared to existing drainage models, DrainFlow has the advantage of estimating actual infiltration directly from the partial differential form of Richard's equation rather than through analytical or empirical infiltration approaches like the Green and Ampt equation.

  2. Testing MODFLOW-LGR for simulating flow around buried Quaternary valleys - synthetic test cases

    NASA Astrophysics Data System (ADS)

    Vilhelmsen, T. N.; Christensen, S.

    2009-12-01

    In this study the Local Grid Refinement (LGR) method developed for MODFLOW-2005 (Mehl and Hill, 2005) is utilized to describe groundwater flow in areas containing buried Quaternary valley structures. The tests are conducted as comparative analysis between simulations run with a globally refined model, a locally refined model, and a globally coarse model, respectively. The models vary from simple one layer models to more complex ones with up to 25 model layers. The comparisons of accuracy are conducted within the locally refined area and focus on water budgets, simulated heads, and simulated particle traces. Simulations made with the globally refined model are used as reference (regarded as “true” values). As expected, for all test cases the application of local grid refinement resulted in more accurate results than when using the globally coarse model. A significant advantage of utilizing MODFLOW-LGR was that it allows increased numbers of model layers to better resolve complex geology within local areas. This resulted in more accurate simulations than when using either a globally coarse model grid or a locally refined model with lower geological resolution. Improved accuracy in the latter case could not be expected beforehand because difference in geological resolution between the coarse parent model and the refined child model contradicts the assumptions of the Darcy weighted interpolation used in MODFLOW-LGR. With respect to model runtimes, it was sometimes found that the runtime for the locally refined model is much longer than for the globally refined model. This was the case even when the closure criteria were relaxed compared to the globally refined model. These results are contradictory to those presented by Mehl and Hill (2005). Furthermore, in the complex cases it took some testing (model runs) to identify the closure criteria and the damping factor that secured convergence, accurate solutions, and reasonable runtimes. For our cases this is judged to

  3. Low-flow operation and testing of pumps in nuclear plants

    SciTech Connect

    Greenstreet, W.L.

    1989-01-01

    Low-flow operation of centrifugal pumps introduces hydraulic instability and other factors that can cause damage to these machines. The resulting degradation has been studied and recorded for pumps in electric power plants. The objectives of this paper are to (1) describe the damage-producing phenomena, including their sources and consequences; (2) relate these observations to expectations for damage caused by low-flow operation of pumps in nuclear power plants; and (3) assess the utility of low-flow testing. Hydraulic behavior during low-flow operation is reviewed for a typical centrifugal pump stage, and the damage-producing mechanisms are described. Pump monitoring practices, in conjunction with pump performance characteristics, are considered; experience data are reviewed; and the effectiveness of low-flow surveillance monitoring is examined. Degradation caused by low-flow operation is shown to be an important factor, and low-flow surveillance testing is shown to be inadequate. 18 refs., 5 figs., 4 tabs.

  4. Numerical Calibration of Mass Flow Plug for Inlet Testing

    NASA Technical Reports Server (NTRS)

    Sasson, Jonathan; Barnhart, Paul; Davis, David O.

    2015-01-01

    A simple control volume model has been developed to calculate the discharge coefficient through a mass flow plug (MFP) and validated with a calibration experiment. The maximum error of the model within the operating region of the MFP is 0.54%. The control volume analysis developed work is comprised of a sequence of flow calculations through the MFP. The model uses the MFP geometry and operating pressure and temperature to couple continuity, momentum, energy, an equation of state, and wall shear. The discharge coefficient calculation also includes the effects of boundary layer growth, including the reduction in cross-sectional flow area as characterized by the boundary layer displacement thickness. The last calculation in the sequence uses an integral method to calculate the growth of the boundary layer, from which the displacement thickness is then determined. The result of these successive calculations is an accurate one-dimension model of the velocity, pressure, and temperature through the MFP. For comparison, a computational fluid dynamic (CFD) calibration is shown, which when compared to the presented numerical model, had a lower accuracy with a maximum error of 1.35% in addition to being slower by a factor of 100."

  5. Pre-test CFD Calculations for a Bypass Flow Standard Problem

    SciTech Connect

    Rich Johnson

    2011-11-01

    The bypass flow in a prismatic high temperature gas-cooled reactor (HTGR) is the flow that occurs between adjacent graphite blocks. Gaps exist between blocks due to variances in their manufacture and installation and because of the expansion and shrinkage of the blocks from heating and irradiation. Although the temperature of fuel compacts and graphite is sensitive to the presence of bypass flow, there is great uncertainty in the level and effects of the bypass flow. The Next Generation Nuclear Plant (NGNP) program at the Idaho National Laboratory has undertaken to produce experimental data of isothermal bypass flow between three adjacent graphite blocks. These data are intended to provide validation for computational fluid dynamic (CFD) analyses of the bypass flow. Such validation data sets are called Standard Problems in the nuclear safety analysis field. Details of the experimental apparatus as well as several pre-test calculations of the bypass flow are provided. Pre-test calculations are useful in examining the nature of the flow and to see if there are any problems associated with the flow and its measurement. The apparatus is designed to be able to provide three different gap widths in the vertical direction (the direction of the normal coolant flow) and two gap widths in the horizontal direction. It is expected that the vertical bypass flow will range from laminar to transitional to turbulent flow for the different gap widths that will be available.

  6. Seismic monitoring of a flow test in the Salton Sea Geothermal Field

    SciTech Connect

    Jarpe, S.P.; Kasameyer, P.W.; Johnston, C.

    1989-06-01

    The purpose of this seismic monitoring project was to characterize in detail the micro-seismic activity related to the flow-injection test in the Salton Sea Geothermal Field. Our goal was to determine if any sources of seismic energy related to the test were observable at the surface, using both conventional seismic network techniques and relatively newer array techniques. These methods allowed us to detect and locate both impulsive microearthquakes and continuous sources of seismic energy. Our network, which was sensitive enough to be triggered by magnitude 0.0 or larger events, found no impulsive microearthquakes in the vicinity of the flow test in the 8 month period before the test and only one event during the flow test. We have observed some continuous seismic noise sources that may be attributed to the flow test. 4 refs., 4 figs.

  7. Rayleigh Scattering for Measuring Flow in a Nozzle Testing Facility

    NASA Technical Reports Server (NTRS)

    Gomez, Carlos R.; Panda, Jayanta

    2006-01-01

    A molecular Rayleigh-scattering-based air-density measurement system was built in a large nozzle-and-engine-component test facility for surveying supersonic plumes from jet-engine exhaust. A molecular Rayleigh-scattering-based air-density measurement system was built in a large nozzle-and-enginecomponent test facility for surveying supersonic plumes from jet-engine exhaust

  8. Test of pressure transducer for measuring cotton-mass flow

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In this study, a cotton harvester yield monitor was developed based on the relationship between air pressure and the mass of seed cotton conveyed. The sensor theory was verified by laboratory tests. The sensor was tested on a cotton picker with seed cotton at two moisture contents, 5.9% and 8.5% we...

  9. Validation of non-Darcian flow effects in slug tests conducted in fractured rock boreholes

    NASA Astrophysics Data System (ADS)

    Quinn, Patryk M.; Parker, Beth L.; Cherry, John A.

    2013-04-01

    SummaryA series of rising and falling head slug tests with different initial applied head differentials (ΔHo) were conducted in open fractured dolostone and sandstone boreholes using straddle packers isolating specific depth intervals (1.5 m length) to examine the influence of non-Darcian flow. The open holes were developed and inspected using video and acoustic televiewing (ATV) to ensure that evidence of skin effects due to drilling were absent. The transmissivity (T) values obtained from both the rising and falling head slug tests were very similar at low initial applied head; however, the T values were progressively smaller at larger ΔHo, suggesting error due to non-Darcian flow. Non-Darcian flow behavior was confirmed by constant head step tests conducted in the same test intervals where the injection rate (Q) vs. applied head (dH) relationship became non-linear at relatively low injection rates, and the non-Darcian data also resulted in lower T values. For a series of slug tests conducted at different ΔHo, non-Darcian flow effects gradually increased as ΔHo increased, consistent with the trends for constant head step tests conducted in the same test intervals. To maintain Darcian flow conditions in the fractured dolostone and sandstone tested in this study, ΔHo must be kept small, generally less than 0.2 m. This study demonstrates that by conducting both "stepped" slug tests and constant head step tests, the Darcian flow assumption for both types of tests can be rigorously validated. However, when only slug tests are conducted, it is necessary to conduct a series of "stepped" slug tests, including tests with small applied head differentials, to avoid errors due to non-Darcian flow.

  10. Well-test analysis for non-Newtonian fluid flow

    SciTech Connect

    Vongvuthipornchai, S.

    1985-01-01

    This dissertation examines pressure behavior subsequent to the injection of a non-Newtonian power-law pseudoplastic fluid. Responses at an unfractured well and at a well intercepting a planar fracture or a finite-conductivity fracture are studied. A rigorous examination of both injection and falloff responses is presented. Two approximate solutions for the transient (radial) flow presented in the literature are examined. The use of these solutions to analyze falloff data and correction factors needed are investigated. The influence of injection time on falloff data is documented. The influence of wellbore storage and skin on pressure responses is considered. The effective wellbore radius concept is used to combine the wellbore storage constant and the skin factor. Infinite-conductivity and uniform-flux idealizations are used to examine responses at wells intercepting planar fractures. Procedures to identify flow regimes are discussed. The solutions presented here may be used to determine fluid mobility, fracture half-length and the power-law index. Procedures to analyze pressure data during pseudoradial flow are also discussed. The effective wellbore radius concept is used to relate the skin factor with fracture half-length. Also, the utility of the pressure derivative techniques and the influence of injection time on the ability to analyze falloff data are documented. Lastly, pressure responses at a well intercepting a finite-conductivity fracture are examined. The parameters that govern the well response are identified. The solutions presented here may be used to obtain fracture half-length, fluid mobility and fracture conductivity, provided that the power-law index is known. All solutions were obtained by using standard finite-difference techniques.

  11. [Flow field test on the tangential section of polypropylene tubular membrane module annular gap in rotating linear tangential flow].

    PubMed

    Wang, Chengduan; Chen, Wenmei; Li, Jianming; Jiang, Guangming

    2002-07-01

    A new type of polypropylene tubular membrane apparatus of rotating cross flow was designed to study experimentally the flow field characteristics of the tangential section of the membrane annular gap. The authors designed rotary linear tangential flow tubular membrane separator and its test system for the first time. Through the system, the flow field of rotary linear tangential flow with the advanced Particle Image Velocimetry (PIV) was tested for the first time. A lot of streamlines and vorticity maps of the tangential section of separator in different operation conditions were obtained. The velocity distribution characteristics were analyzed quantitatively: 1. At non-vortex area, no matter how the operation parameters change, the velocity near to rotary tangential flow entrance was higher than the velocity far from entrance at the same radial coordinates. At vortex area, generally the flow velocity of inner vortex was lower than the outer vortex. At the vortex center, the velocity was lowest, the tangential velocity were equal to zero generally. At the vortex center zone, the tangential velocity was less than the axial velocity. 2. Under test operations, the tangential velocity and axial velocity of vortices borders are 1-2 times of average axial velocity of membrane module annular gap. The maximum tangential velocity and axial velocity of ellipse vortices were 2-6 times of average axial velocity of membrane module annular gap. 3. The vortices that are formed on the tangential section, there existed mass transfer between inner and outer parts of fluid. Much fluid of outer vortices got into the inner ones, which was able to prevent membrane tube from particles blocking up very soon. PMID:12371104

  12. Thermal mixing tests in a semiannular downcomer with interacting flows from cold legs: International Agreement Report

    SciTech Connect

    Tuomisto, H; Mustonen, P

    1986-10-01

    This report describes the test facility and test program for studying thermal mixing of high-pressure injection (HPI) water in the two-fifths scale model of three cold legs, semiannular downcomer and lower plenum of a pressurized water reactor. This test series has been carried out by mutual agreement on the pressurized thermal shock (PTS) information exchange between the US Nuclear Regulation Commission and Imatran Voima Oy. The test facility was originally designed to model the Finnish Loviisa plant but it was redesigned and modified for this test program. The facility can be operated at atmospheric pressure with loop and HPI flows from different cold legs in the area of interest to PTS. Transparent materials were used to allow flow visualization during the tests. The choice of transparent materials limit the upper temperature to 75/sup 0/C. The full buoyancy effect was induced by salt addition and the HPI temperature was used as a tracer. The test matrix consists of 20 tests. The varied parameters were flow rates and the number and configuration of cold legs with HPI and loop flows. Four tests were done with decreasing loop flow temperature to simulate primary flows during steam line breaks.

  13. Core Dynamics Analysis for Reactivity Insertion and Loss of Coolant Flow Tests Using the High Temperature Engineering Test Reactor

    NASA Astrophysics Data System (ADS)

    Takamatsu, Kuniyoshi; Nakagawa, Shigeaki; Takeda, Tetsuaki

    Safety demonstration tests using the High Temperature Engineering Test Reactor (HTTR) are in progress to verify its inherent safety features and improve the safety technology and design methodology for High-temperature Gas-cooled Reactors (HTGRs). The reactivity insertion test is one of the safety demonstration tests for the HTTR. This test simulates the rapid increase in the reactor power by withdrawing the control rod without operating the reactor power control system. In addition, the loss of coolant flow tests has been conducted to simulate the rapid decrease in the reactor power by tripping one, two or all out of three gas circulators. The experimental results have revealed the inherent safety features of HTGRs, such as the negative reactivity feedback effect. The numerical analysis code, which was named-ACCORD-, was developed to analyze the reactor dynamics including the flow behavior in the HTTR core. We have modified this code to use a model with four parallel channels and twenty temperature coefficients. Furthermore, we added another analytical model of the core for calculating the heat conduction between the fuel channels and the core in the case of the loss of coolant flow tests. This paper describes the validation results for the newly developed code using the experimental results. Moreover, the effect of the model is formulated quantitatively with our proposed equation. Finally, the pre-analytical result of the loss of coolant flow test by tripping all gas circulators is also discussed.

  14. Development of Flow Boiling and Condensation Experiment on the International Space Station- Normal and Low Gravity Flow Boiling Experiment Development and Test Results

    NASA Technical Reports Server (NTRS)

    Nahra, Henry K.; Hall, Nancy R.; Hasan, Mohammad M.; Wagner, James D.; May, Rochelle L.; Mackey, Jeffrey R.; Kolacz, John S.; Butcher, Robert L.; Frankenfield, Bruce J.; Mudawar, Issam; Konichi, Chris; Hyounsoon, Lee

    2013-01-01

    Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and

  15. Effect of Hospital Use of Oral Nutritional Supplementation on Length of Stay, Hospital Cost, and 30-Day Readmissions Among Medicare Patients With COPD

    PubMed Central

    Snider, Julia Thornton; Linthicum, Mark T.; Hegazi, Refaat A.; Partridge, Jamie S.; LaVallee, Chris; Lakdawalla, Darius N.; Wischmeyer, Paul E.

    2015-01-01

    BACKGROUND: COPD is a leading cause of death and disability in the United States. Patients with COPD are at a high risk of nutritional deficiency, which is associated with declines in respiratory function, lean body mass and strength, and immune function. Although oral nutritional supplementation (ONS) has been associated with improvements in some of these domains, the impact of hospital ONS on readmission risk, length of stay (LOS), and cost among hospitalized patients is unknown. METHODS: Using the Premier Research Database, we first identified Medicare patients aged ≥ 65 years hospitalized with a primary diagnosis of COPD. We then identified hospitalizations in which ONS was provided, and used propensity-score matching to compare LOS, hospitalization cost, and 30-day readmission rates in a one-to-one matched sample of ONS and non-ONS hospitalizations. To further address selection bias among patients prescribed ONS, we also used instrumental variables analysis to study the association of ONS with study outcomes. Model covariates included patient and provider characteristics and a time trend. RESULTS: Out of 10,322 ONS hospitalizations and 368,097 non-ONS hospitalizations, a one-to-one matched sample was created (N = 14,326). In unadjusted comparisons in the matched sample, ONS use was associated with longer LOS (8.7 days vs 6.9 days, P < .0001), higher hospitalization cost ($14,223 vs $9,340, P < .0001), and lower readmission rates (24.8% vs 26.6%, P = .0116). However, in instrumental variables analysis, ONS use was associated with a 1.9-day (21.5%) decrease in LOS, from 8.8 to 6.9 days (P < .01); a hospitalization cost reduction of $1,570 (12.5%), from $12,523 to $10,953 (P < .01); and a 13.1% decrease in probability of 30-day readmission, from 0.34 to 0.29 (P < .01). CONCLUSIONS: ONS may be associated with reduced LOS, hospitalization cost, and readmission risk in hospitalized Medicare patients with COPD. PMID:25357165

  16. Risk factors for unplanned readmission within 30 days after pediatric neurosurgery: a nationwide analysis of 9799 procedures from the American College of Surgeons National Surgical Quality Improvement Program.

    PubMed

    Sherrod, Brandon A; Johnston, James M; Rocque, Brandon G

    2016-09-01

    OBJECTIVE Hospital readmission rate is increasingly used as a quality outcome measure after surgery. The purpose of this study was to establish, using a national database, the baseline readmission rates and risk factors for patient readmission after pediatric neurosurgical procedures. METHODS The American College of Surgeons National Surgical Quality Improvement Program-Pediatric database was queried for pediatric patients treated by a neurosurgeon between 2012 and 2013. Procedures were categorized by current procedural terminology (CPT) code. Patient demographics, comorbidities, preoperative laboratory values, operative variables, and postoperative complications were analyzed via univariate and multivariate techniques to find associations with unplanned readmissions within 30 days of the primary procedure. RESULTS A total of 9799 cases met the inclusion criteria, 1098 (11.2%) of which had an unplanned readmission within 30 days. Readmission occurred 14.0 ± 7.7 days postoperatively (mean ± standard deviation). The 4 procedures with the highest unplanned readmission rates were CSF shunt revision (17.3%; CPT codes 62225 and 62230), repair of myelomeningocele > 5 cm in diameter (15.4%), CSF shunt creation (14.1%), and craniectomy for infratentorial tumor excision (13.9%). The lowest unplanned readmission rates were for spine (6.5%), craniotomy for craniosynostosis (2.1%), and skin lesion (1.0%) procedures. On multivariate regression analysis, the odds of readmission were greatest in patients experiencing postoperative surgical site infection (SSI; deep, organ/space, superficial SSI, and wound disruption: OR > 12 and p < 0.001 for each). Postoperative pneumonia (OR 4.294, p < 0.001), urinary tract infection (OR 4.262, p < 0.001), and sepsis (OR 2.616, p = 0.006) also independently increased the readmission risk. Independent patient risk factors for unplanned readmission included Native American race (OR 2.363, p = 0.019), steroid use > 10 days (OR 1.411, p = 0

  17. Risk factors for unplanned readmission within 30 days after pediatric neurosurgery: a nationwide analysis of 9799 procedures from the American College of Surgeons National Surgical Quality Improvement Program.

    PubMed

    Sherrod, Brandon A; Johnston, James M; Rocque, Brandon G

    2016-09-01

    OBJECTIVE Hospital readmission rate is increasingly used as a quality outcome measure after surgery. The purpose of this study was to establish, using a national database, the baseline readmission rates and risk factors for patient readmission after pediatric neurosurgical procedures. METHODS The American College of Surgeons National Surgical Quality Improvement Program-Pediatric database was queried for pediatric patients treated by a neurosurgeon between 2012 and 2013. Procedures were categorized by current procedural terminology (CPT) code. Patient demographics, comorbidities, preoperative laboratory values, operative variables, and postoperative complications were analyzed via univariate and multivariate techniques to find associations with unplanned readmissions within 30 days of the primary procedure. RESULTS A total of 9799 cases met the inclusion criteria, 1098 (11.2%) of which had an unplanned readmission within 30 days. Readmission occurred 14.0 ± 7.7 days postoperatively (mean ± standard deviation). The 4 procedures with the highest unplanned readmission rates were CSF shunt revision (17.3%; CPT codes 62225 and 62230), repair of myelomeningocele > 5 cm in diameter (15.4%), CSF shunt creation (14.1%), and craniectomy for infratentorial tumor excision (13.9%). The lowest unplanned readmission rates were for spine (6.5%), craniotomy for craniosynostosis (2.1%), and skin lesion (1.0%) procedures. On multivariate regression analysis, the odds of readmission were greatest in patients experiencing postoperative surgical site infection (SSI; deep, organ/space, superficial SSI, and wound disruption: OR > 12 and p < 0.001 for each). Postoperative pneumonia (OR 4.294, p < 0.001), urinary tract infection (OR 4.262, p < 0.001), and sepsis (OR 2.616, p = 0.006) also independently increased the readmission risk. Independent patient risk factors for unplanned readmission included Native American race (OR 2.363, p = 0.019), steroid use > 10 days (OR 1.411, p = 0

  18. An evaluation of pressure and flow measurement in the Molten Salt Test Loop (MSTL) system.

    SciTech Connect

    Gill, David Dennis; Kolb, William J.; Briggs, Ronald J.

    2013-07-01

    The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL allows customers and researchers to test components in flowing, molten nitrate salt at plant-like conditions for pressure, flow, and temperature. An important need in thermal storage systems that utilize molten salts is for accurate flow and pressure measurement at temperatures above 535ÀC. Currently available flow and pressure instrumentation for molten salt is limited to 535ÀC and even at this temperature the pressure measurement appears to have significant variability. It is the design practice in current Concentrating Solar Power plants to measure flow and pressure on the cold side of the process or in dead-legs where the salt can cool, but this practice wont be possible for high temperature salt systems. For this effort, a set of tests was conducted to evaluate the use of the pressure sensors for flow measurement across a device of known flow coefficient Cv. To perform this task, the pressure sensors performance was evaluated and was found to be lacking. The pressure indicators are severely affected by ambient conditions and were indicating pressure changes of nearly 200psi when there was no flow or pressure in the system. Several iterations of performance improvement were undertaken and the pressure changes were reduced to less than 15psi. The results of these pressure improvements were then tested for use as flow measurement. It was found that even with improved pressure sensors, this is not a reliable method of flow measurement. The need for improved flow and pressure measurement at high temperatures remains and will need to be solved before it will be possible to move to high temperature thermal storage systems with molten salts.

  19. Flow Quality Studies of the NASA Glenn Research Center Icing Research Tunnel Circuit (1995 Tests)

    NASA Technical Reports Server (NTRS)

    Arrington, E. Allen; Kee-Bowling, Bonnie A.; Gonsalez, Jose C.

    2000-01-01

    The purpose of conducting the flow-field surveys described in this report was to more fully document the flow quality in several areas of the tunnel circuit in the NASA Glenn Research Center Icing Research Tunnel. The results from these surveys provide insight into areas of the tunnel that were known to exhibit poor flow quality characteristics and provide data that will be useful to the design of flow quality improvements and a new heat exchanger for the facility. An instrumented traversing mechanism was used to survey the flow field at several large cross sections of the tunnel loop over the entire speed range of the facility. Flow-field data were collected at five stations in the tunnel loop, including downstream of the fan drive motor housing, upstream and downstream of the heat exchanger, and upstream and downstream of the spraybars located in the settling chamber upstream of the test section. The data collected during these surveys greatly expanded the data base describing the flow quality in each of these areas. The new data matched closely the flow quality trends recorded from earlier tests. Data collected downstream of the heat exchanger and in the settling chamber showed how the configuration of the folded heat exchanger affected the pressure, velocity, and flow angle distributions in these areas. Smoke flow visualization was also used to qualitatively study the flow field in an area downstream of the drive fan and in the settling chamber/contraction section.

  20. Fluctuating Pressure Data from 2-D Nozzle Cold Flow Tests (Dual Bell)

    NASA Technical Reports Server (NTRS)

    Nesman, Tomas E.

    2001-01-01

    Rocket engines nozzle performance changes as a vehicle climbs through the atmosphere. An altitude compensating nozzle, ACN, is intended to improve on a fixed geometry bell nozzle that performs at optimum at only one trajectory point. In addition to nozzle performance, nozzle transient loads are an important consideration. Any nozzle experiences large transient toads when shocks pass through the nozzle at start and shutdown. Additional transient toads will occur at transitional flow conditions. The objectives of cold flow nozzle testing at MSFC are CFD benchmark / calibration and Unsteady flow / sideloads. Initial testing performed with 2-D inserts to 14" transonic wind tunnel. Recent review of 2-D data in preparation for nozzle test facility 3-D testing. This presentation shows fluctuating pressure data and some observations from 2-D dual-bell nozzle cold flow tests.

  1. Bentonite borehole plug flow testing with five water types

    SciTech Connect

    Gaudette, M.V.; Daemen, J.J.K.

    1988-04-01

    The hydraulic conductivity has been determined of plugs constructed with commercial precompressed bentonite pellets. Bentonite has been hydrated and tested with waters of five different chemical compositions, including one groundwater (Ogallala aquifer, Texas). The groundwater contained a significant amount of solids: waters prepared in the laboratory did not. Prepared waters used for testing included distilled water, a high (1000 ppM) and a low (45 ppM) calcium solution, and a 39 ppM sodium water. Uncompacted plugs were constructed by dropping bentonite tablets into waterfilled cylinders, or by mixing powdered bentonite with preselected water volumes in order to obtain controlled initial water contents. The hydraulic conductivity of all plugs tested with all waters would result in a classification of practically impervious, by conventional soil mechanics standards. Variations of several orders of magnitude of the hydraulic conductivity are observed.

  2. Design and Implementation of a Characterization Test Rig for Evaluating High Bandwidth Liquid Fuel Flow Modulators

    NASA Technical Reports Server (NTRS)

    Saus, Joseph R.; Chang, Clarence T.; DeLaat, John C.; Vrnak, Daniel R.

    2010-01-01

    A test rig was designed and developed at the NASA Glenn Research Center (GRC) for the purpose of characterizing high bandwidth liquid fuel flow modulator candidates to determine their suitability for combustion instability control research. The test rig is capable of testing flow modulators at up to 600 psia supply pressure and flows of up to 2 gpm. The rig is designed to provide a quiescent flow into the test section in order to isolate the dynamic flow modulations produced by the test article. Both the fuel injector orifice downstream of the test article and the combustor are emulated. The effect of fuel delivery line lengths on modulator dynamic performance can be observed and modified to replicate actual fuel delivery systems. For simplicity, water is currently used as the working fluid, although future plans are to use jet fuel. The rig is instrumented for dynamic pressures and flows and a high-speed data system is used for dynamic data acquisition. Preliminary results have been obtained for one candidate flow modulator.

  3. Field testing the hypothesis of Darcian flow through a carbonate aquifer.

    USGS Publications Warehouse

    Hickey, J.J.

    1984-01-01

    The acceptability of the hypothesis of Darcian flow through a semiconfined carbonate aquifer was tested prior to running a multiple-day aquifer test in Pinellas County, Florida. The approach used to test the hypothesis was to run a number of hour-long aquifer tests at different discharges with drawdown measured at the same time during each test in two observation wells, one at 35 feet and the other at 733 feet from the pumped well. The hypothesis of Darcian flow through the semiconfined carbonate aquifer was deemed acceptable.-from Author

  4. 10 CFR 431.264 - Uniform test method for the measurement of flow rate for commercial prerinse spray valves.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Valves Test Procedures § 431.264 Uniform test method for the measurement of flow rate for commercial..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed...

  5. 10 CFR 431.264 - Uniform test method for the measurement of flow rate for commercial prerinse spray valves.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Valves Test Procedures § 431.264 Uniform test method for the measurement of flow rate for commercial..., the water consumption flow rate of commercial prerinse spray valves. (b) Testing and Calculations. The test procedure to determine the water consumption flow rate for prerinse spray valves, expressed...

  6. Phase 2: HGM air flow tests in support of HEX vane investigation

    NASA Technical Reports Server (NTRS)

    Cox, G. B., Jr.; Steele, L. L.; Eisenhart, D. W.

    1993-01-01

    Following the start of SSME certification testing for the Pratt and Whitney Alternate Turbopump Development (ATD) High Pressure Oxidizer Turbopump (HPOTP), cracking of the leading edge of the inner HEX vane was experienced. The HEX vane, at the inlet of the oxidizer bowl in the Hot Gas Manifold (HGM), accepts the HPOTP turbine discharge flow and turns it toward the Gaseous Oxidizer Heat Exchanger (GOX HEX) coil. The cracking consistently initiated over a specific circumferential region of the hex vane, with other circumferential locations appearing with increased run time. Since cracking had not to date been seen with the baseline HPOTP, a fluid-structural interaction involving the ATD HPOTP turbine exit flowfield and the HEX inner vane was suspected. As part of NASA contract NAS8-36801, Pratt and Whitney conducted air flow tests of the ATD HPOTP turbine turnaround duct flowpath in the MSFC Phase 2 HGM air flow model. These tests included HEX vane strain gages and additional fluctuating pressure gages in the turnaround duct and HEX vane flowpath area. Three-dimensional flow probe measurements at two stations downstream of the turbine simulator exit plane were also made. Modifications to the HPOTP turbine simulator investigated the effects on turbine exit flow profile and velocity components, with the objective of reproducing flow conditions calculated for the actual ATD HPOTP hardware. Testing was done at the MSFC SSME Dynamic Fluid Air Flow (Dual-Leg) Facility, at air supply pressures between 50 and 250 psia. Combinations of turbine exit Mach number and pressure level were run to investigate the effect of flow regime. Information presented includes: (1) Descriptions of turbine simulator modifications to produce the desired flow environment; (2) Types and locations for instrumentation added to the flow model for improved diagnostic capability; (3) Evaluation of the effect of changes to the turbine simulator flowpath on the turbine exit flow environment; and (4

  7. Cerebral blood flow response pattern during balloon test occlusion of the internal carotid artery

    SciTech Connect

    Witt, J.P.; Yonas, H.; Jungreis, C.

    1994-05-01

    To evaluate the risk of temporary or permanent internal carotid artery occlusion. In 156 patients intraarterial balloon test occlusion in combination with a stable xenon-enhanced CT cerebral blood flow study was performed before radiologic or surgical treatment. All 156 patients passed the clinical balloon test occlusion and underwent a xenon study in combination with a second balloon test. Quantitative flow data were analyzed for absolute changes as well as changes in symmetry. Fourteen patients exhibited reduced flow values between 20 and 30 mL/100 g per minute, an absolute decrease in flow, and significant asymmetry in the middle cerebral artery territory during balloon test occlusion. These patients would be considered at high risk for cerebral infarction if internal carotid artery occlusion were to be performed. With one exception they belonged to a group (class I) of 61 patients who showed bilateral or ipsilateral flow decrease and significant asymmetry with lower flow on the side of occlusion. The other 95 patients, who showed a variety of cerebral blood flow response patterns including ipsilateral or bilateral flow increase, were at moderate (class II) or low (class III) stroke risk. In contrast to these findings, exclusively qualitative flow analysis failed to identify the patients at high risk: a threshold with an asymmetry index of 10% revealed only 16% specificity whereas an asymmetry index of 45% showed only 61% sensitivity for detection of low flow areas (<30 mL/100 g per minute). For achieving a minimal hemodynamic related-stroke rate associated with permanent clinical internal carotid artery occlusion we suggest integration of a thorough analysis of quantitative cerebral blood flow data before and during balloon test occlusion. 68 refs., 5 figs., 2 tabs.

  8. Isoform composition and gene expression of thick and thin filament proteins in striated muscles of mice after 30-day space flight.

    PubMed

    Ulanova, Anna; Gritsyna, Yulia; Vikhlyantsev, Ivan; Salmov, Nikolay; Bobylev, Alexander; Abdusalamova, Zarema; Rogachevsky, Vadim; Shenkman, Boris; Podlubnaya, Zoya

    2015-01-01

    Changes in isoform composition, gene expression of titin and nebulin, and isoform composition of myosin heavy chains as well as changes in titin phosphorylation level in skeletal (m. gastrocnemius, m. tibialis anterior, and m. psoas) and cardiac muscles of mice were studied after a 30-day-long space flight onboard the Russian spacecraft "BION-M" number 1. A muscle fibre-type shift from slow-to-fast and a decrease in the content of titin and nebulin in the skeletal muscles of animals from "Flight" group was found. Using Pro-Q Diamond staining, an ~3-fold increase in the phosphorylation level of titin in m. gastrocnemius of mice from the "Flight" group was detected. The content of titin and its phosphorylation level in the cardiac muscle of mice from "Flight" and "Control" groups did not differ; nevertheless an increase (2.2 times) in titin gene expression in the myocardium of flight animals was found. The observed changes are discussed in the context of their role in the contractile activity of striated muscles of mice under conditions of weightlessness.

  9. [Desmin content and transversal stiffness of the left ventricle mouse cardiomyocytes and skeletal muscle fibers after a 30-day space flight on board "BION-M1" biosatellite].

    PubMed

    Ogneva, I V; Maximova, M V; Larina, I M

    2014-01-01

    The aim of this study was to determine the transversal stiffness of the cortical cytoskeleton and the cytoskeletal protein desmin content in the left ventricle cardiomyocytes, fibers of the mouse soleus and tibialis anterior muscle after a 30-day space flight on board the "BION-M1" biosatellite (Russia, 2013). The dissection was made after 13-16.5 h after landing. The transversal stiffness was measured in relaxed and calcium activated state by, atomic force microscopy. The desmin content was estimated by western blotting, and the expression level of desmin-coding gene was detected using real-time PCR. The results indicate that, the transversal stiffness of the left ventricle cardiomyocytes and fibers of the soleus muscle in relaxed and activated states did not differ from the control. The transversal stiffness of the tibialis muscle fibers in relaxed and activated state was increased in the mice group after space flight. At the same time, in all types of studied tissues the desmin content and the expression level of desmin-coding gene did not differ from the control level.

  10. Isoform Composition and Gene Expression of Thick and Thin Filament Proteins in Striated Muscles of Mice after 30-Day Space Flight

    PubMed Central

    Ulanova, Anna; Gritsyna, Yulia; Vikhlyantsev, Ivan; Salmov, Nikolay; Bobylev, Alexander; Abdusalamova, Zarema; Rogachevsky, Vadim; Shenkman, Boris; Podlubnaya, Zoya

    2015-01-01

    Changes in isoform composition, gene expression of titin and nebulin, and isoform composition of myosin heavy chains as well as changes in titin phosphorylation level in skeletal (m. gastrocnemius, m. tibialis anterior, and m. psoas) and cardiac muscles of mice were studied after a 30-day-long space flight onboard the Russian spacecraft “BION-M” number 1. A muscle fibre-type shift from slow-to-fast and a decrease in the content of titin and nebulin in the skeletal muscles of animals from “Flight” group was found. Using Pro-Q Diamond staining, an ~3-fold increase in the phosphorylation level of titin in m. gastrocnemius of mice from the “Flight” group was detected. The content of titin and its phosphorylation level in the cardiac muscle of mice from “Flight” and “Control” groups did not differ; nevertheless an increase (2.2 times) in titin gene expression in the myocardium of flight animals was found. The observed changes are discussed in the context of their role in the contractile activity of striated muscles of mice under conditions of weightlessness. PMID:25664316

  11. Isoform composition and gene expression of thick and thin filament proteins in striated muscles of mice after 30-day space flight.

    PubMed

    Ulanova, Anna; Gritsyna, Yulia; Vikhlyantsev, Ivan; Salmov, Nikolay; Bobylev, Alexander; Abdusalamova, Zarema; Rogachevsky, Vadim; Shenkman, Boris; Podlubnaya, Zoya

    2015-01-01

    Changes in isoform composition, gene expression of titin and nebulin, and isoform composition of myosin heavy chains as well as changes in titin phosphorylation level in skeletal (m. gastrocnemius, m. tibialis anterior, and m. psoas) and cardiac muscles of mice were studied after a 30-day-long space flight onboard the Russian spacecraft "BION-M" number 1. A muscle fibre-type shift from slow-to-fast and a decrease in the content of titin and nebulin in the skeletal muscles of animals from "Flight" group was found. Using Pro-Q Diamond staining, an ~3-fold increase in the phosphorylation level of titin in m. gastrocnemius of mice from the "Flight" group was detected. The content of titin and its phosphorylation level in the cardiac muscle of mice from "Flight" and "Control" groups did not differ; nevertheless an increase (2.2 times) in titin gene expression in the myocardium of flight animals was found. The observed changes are discussed in the context of their role in the contractile activity of striated muscles of mice under conditions of weightlessness. PMID:25664316

  12. A Study of a Network-Flow Algorithm and a Noncorrecting Algorithm for Test Assembly.

    ERIC Educational Resources Information Center

    Armstrong, R. D.; And Others

    1996-01-01

    When the network-flow algorithm (NFA) and the average growth approximation algorithm (AGAA) were used for automated test assembly with American College Test and Armed Services Vocational Aptitude Battery item banks, results indicate that reasonable error in item parameters is not harmful for test assembly using NFA or AGAA. (SLD)

  13. Flow for Exercise Adherence: Testing an Intrinsic Model of Health Behavior

    ERIC Educational Resources Information Center

    Petosa, R. Lingyak; Holtz, Brian

    2013-01-01

    Background: Health behavior theory generally does not include intrinsic motivation as a determinate of health practices. Purpose: The purpose of this study was to test the flow theory of exercise adherence. Flow theory posits that exercise can be intrinsically rewarding if the experiences of self/time transcendence and control/mastery are achieved…

  14. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Gas flow test; closed-circuit apparatus. 84.94 Section 84.94 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.94 Gas flow...

  15. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Gas flow test; open-circuit apparatus. 84.93 Section 84.93 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.93 Gas flow...

  16. In vitro blood flow model with physiological wall shear stress for hemocompatibility testing-An example of coronary stent testing.

    PubMed

    Engels, Gerwin Erik; Blok, Sjoerd Leendert Johannes; van Oeveren, Willem

    2016-01-01

    Hemocompatibility of blood contacting medical devices has to be evaluated before their intended application. To assess hemocompatibility, blood flow models are often used and can either consist of in vivo animal models or in vitro blood flow models. Given the disadvantages of animal models, in vitro blood flow models are an attractive alternative. The in vitro blood flow models available nowadays mostly focus on generating continuous flow instead of generating a pulsatile flow with certain wall shear stress, which has shown to be more relevant in maintaining hemostasis. To address this issue, the authors introduce a blood flow model that is able to generate a pulsatile flow and wall shear stress resembling the physiological situation, which the authors have coined the "Haemobile." The authors have validated the model by performing Doppler flow measurements to calculate velocity profiles and (wall) shear stress profiles. As an example, the authors evaluated the thrombogenicity of two drug eluting stents, one that was already on the market and one that was still under development. After identifying proper conditions resembling the wall shear stress in coronary arteries, the authors compared the stents with each other and often used reference materials. These experiments resulted in high contrast between hemocompatible and incompatible materials, showing the exceptional testing capabilities of the Haemobile. In conclusion, the authors have developed an in vitro blood flow model which is capable of mimicking physiological conditions of blood flow as close as possible. The model is convenient in use and is able to clearly discriminate between hemocompatible and incompatible materials, making it suitable for evaluating the hemocompatible properties of medical devices. PMID:27435456

  17. PIV characterization of high-Reynolds flow in turbine test facility

    NASA Astrophysics Data System (ADS)

    Chikishev, L. M.; Gobyzov, O. A.; Sharaborin, D. K.; Kravtsov, Z. D.; Dulin, V. M.; Bilsky, A. V.; Markovich, D. M.

    2016-10-01

    This paper reports on application of Stereo Particle Image Velocimetry (Stereo PIV) to measure flow characteristics at high-Reynolds number flow in turbine test facility. The test rig "TS-2" at The Central Institute of Aviation Motors was operated at the pressure up to 2.5 bar, temperature 450°C and flow rates up to 36 kg/s. The main goal of the study was to characterize turbulence intensity and to estimate turbulence integral scale using correlation functions in a test rig immediately before the low pressure aviation turbine. It was found that for different operation pressure (from 1.44 to 2.5 bar) and different flow configuration (with or without turbulent screens) the local turbulence intensity at the inlet of low pressure turbine is about 20 %, but the turbulence integral scale is strongly dependent on the turbine test facility configuration.

  18. A flight test of laminar flow control leading-edge systems

    NASA Technical Reports Server (NTRS)

    Fischer, M. C.; Wright, A. S., Jr.; Wagner, R. D.

    1983-01-01

    NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.

  19. Computer tomography of flows external to test models

    NASA Technical Reports Server (NTRS)

    Prikryl, I.; Vest, C. M.

    1982-01-01

    Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.

  20. Experimental onset of flow instability testing by Creare, Inc. Book 1

    SciTech Connect

    Coutts, D.A.

    1992-11-01

    Flow excursions can occur during subcooled heated flow if the supply system is not adequate to meet the heated channel pressure demand. Available experimental flow instability (FI) data for ribbed annuli such as used in the SRS production reactors is very limited. Creare Inc. completed a series of FI tests which included two annular geometries; one of these included metallic ribs which separated the annulus into four sub-channels. This report summarizes the results of the onset of flow instability (OFI) testing which was completed by Creare in support of the SRS Reactor Restart Program. A copy of the final test report has been attached and the archival locations for the supporting documentation and electronic test data is also included. The purpose of this report is to: Archive the Creare Program data; inspect the data which has been archived; review the results presented by Creare; and evaluate if the Creare Program data may be used in critical applications.

  1. Numerical tests of constitutive laws for dense granular flows.

    PubMed

    Lois, Gregg; Lemaître, Anaël; Carlson, Jean M

    2005-11-01

    We numerically and theoretically study the macroscopic properties of dense, sheared granular materials. In this process we first consider an invariance in Newton's equations, explain how it leads to Bagnold's scaling, and discuss how it relates to the dynamics of granular temperature. Next we implement numerical simulations of granular materials in two different geometries--simple shear and flow down an incline--and show that measurements can be extrapolated from one geometry to the other. Then we observe nonaffine rearrangements of clusters of grains in response to shear strain and show that fundamental observations, which served as a basis for the shear transformation zone (STZ) theory of amorphous solids [M. L. Falk and J. S. Langer, Phys. Rev. E. 57, 7192 (1998); M.R.S. Bull 25, 40 (2000)], can be reproduced in granular materials. Finally we present constitutive equations for granular materials as proposed by Lemaître [Phys. Rev. Lett. 89, 064303 (2002)], based on the dynamics of granular temperature and STZ theory, and show that they match remarkably well with our numerical data from both geometries.

  2. Models, assumptions, and experimental tests of flows near magnetized boundaries

    NASA Astrophysics Data System (ADS)

    Siddiqui, M. Umair

    2015-11-01

    We present a history of research on the magnetized plasma boundary and recent first measurements of particle flows in such structures in laboratory plasmas using multi-dimensional laser-induced fluorescence (LIF). Our measurements show that the canonical model for this boundary proposed in 1982 [Chodura, Phys. Fluids (1982)] is inaccurate for systems where the ion-neutral collision length is less than at least 4 times the ion gyro radius. Rather, our measurements validate more sophisticated plasma boundary fluid models that take neutral collisions into account [Riemann, Phys. Plasmas (1994); Ahedo, Phys. Plasmas (1997); Siddiqui et al., Phys. Plasmas (2014)]. In light of these results, we show that both three-dimensional ion and neutral velocity distribution functions are strongly affected near the boundary. We discuss effects of these perturbed distributions on wall loading and erosion in experiments and applications such as divertor tokamak scrape-off layers and Hall thrusters. Finally, we propose modern definitions of the oft-used term, ``magnetic presheath.'' This work is supported by U.S. National Science Foundation grant number PHY-1360278.

  3. Experiment 2074: post-drilling reservoir flow testing through EE-3A first revision

    SciTech Connect

    Brown, Donald W.; Robinson, Bruce A.

    1987-11-20

    As previously outlined in memorandum ESS-4-87-305 (11/12/87), EE-3A will be pressurized with the Kobe pumps for the next week, and then a sequence of reservoir flow tests and logs will be conducted for a one to two week period beginning Tuesday, 12/1/87. The purpose of this memorandum is to better define this flow test and sequence of logs, organized as a "formal" experiment.

  4. A mercury flow meter for ion thruster testing. [response time, thermal sensitivity

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1973-01-01

    The theory of operation of the thermal flow meter is presented, and a theoretical model is used to determine design parameters for a device capable of measuring mercury flows in the range of 0 to 5 gm/hr. Flow meter construction is described. Tests performed using a positive displacement mercury pump as well as those performed with the device in the feed line of an operating thruster are discussed. A flow meter response time of about a minute and a sensitivity of about 10 mv/gm/hr are demonstrated. Additional work to relieve a sensitivity of the device to variations in ambient temperature is indicated to improve its quantitative performance.

  5. Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

    NASA Technical Reports Server (NTRS)

    Lenahan, Keven C.; Schatzman, David M.; Wilson, Jacob Samuel

    2013-01-01

    Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

  6. [Discussion on testing of flow rate of infusion device about industry standard].

    PubMed

    Hua, Songhe

    2014-07-01

    Carried on the exploration testing of flow rate of infusion device about industry standard YY 0451-2010. Engaged in flow rate experiments adopting different method that are provided by new and old industry standard for samples of the same type. Compared with the result of the dangerous coefficient by calculating the test data, the old standard can be more sensitive to reflect the situation of product flow rate, so it can be applied to conventional control of the products. The method which provided by the new industry standard is suitable for evaluating periodicity the level of product contaminated. PMID:25330614

  7. Coat and claws as new matrices for noninvasive long-term cortisol assessment in dogs from birth up to 30 days of age.

    PubMed

    Veronesi, M C; Comin, A; Meloni, T; Faustini, M; Rota, A; Prandi, A

    2015-09-15

    The last stage of fetal development and the neonatal period represent the most critical phases for the mammals' offspring. In the dog, the knowledge about the final intrauterine fetal development and biology, as well as about the neonatal physiology, remains scarce. Hormonal changes occurring in the last intrauterine fetal phase and during the early neonatal age are still not completely clear, probably because of the invasiveness related to the collection of the more common biological matrix, represented by circulating blood. Toward term of pregnancy, during parturition, and after birth, the hypothalamic-pituitary-adrenal axis is a key system regulating several physiological processes, and its activity was previously investigated by blood analysis, considered an invasive procedure providing a single-point measurement. In respect to animal welfare, and for a more correct long-term retrospective investigation, noninvasive hormonal studies were performed firstly on the hair of humans and coat of animals and, more recently, in the nails of human beings. This study was aimed to assess cortisol (COR) in coat and claws of newborn puppies and to evaluate the possible influence of the newborn gender, breed body size, and age on coat and claws COR concentrations. The results obtained from 165 newborn puppies evidenced that coat and claws COR levels were highly correlated each other (P < 0.0001), although the COR accumulation in the two matrices was different in relation to the class of age. Moreover, the puppies age influenced both coat and claws COR concentrations (P < 0.05), with premature puppies showing higher values when compared to term born-dead puppies or puppies dead between 1 and 30 days of age. The present study reported that COR is quantifiable in coat and claws of newborn dogs. Moreover, both matrices appear as useful tools for new, noninvasive, long-term perinatal and neonatal researches also in canine species.

  8. Structure of cortical cytoskeleton in fibers of mouse muscle cells after being exposed to a 30-day space flight on board the BION-M1 biosatellite.

    PubMed

    Ogneva, I V; Maximova, M V; Larina, I M

    2014-05-15

    The aim of the work was to analyze changes in the organization of the cortical cytoskeleton in fibers of the mouse soleus muscle, tibialis anterior muscle and left ventricular cardiomyocytes after completion of a 30-day space flight on board the BION-M1 biosatellite (Russia, 2013). The transversal stiffness of the cortical cytoskeleton of the cardiomyocytes and fibers of the skeletal muscles did not differ significantly within the study groups compared with the vivarium control group. The content of beta- and gamma-actin in the membranous fraction of proteins in the left ventricular cardiomyocytes did not differ significantly within all study groups and correlated with the transversal stiffness. A similar situation was revealed in fibers of the soleus muscle and tibialis anterior muscle. At the same time, the content of beta-actin in the cytoplasmic fraction of proteins was found to be decreased in all types of studied tissues compared with the control levels in the postflight group, with lowered beta-actin gene expression rates in the postflight group. After completion of the space flight, the content of alpha-actinin-4 was found to be reduced in the membranous fraction of proteins from the mouse cardiomyocytes, while its content in the cytoplasmic fraction of proteins did not change significantly. Furthermore, gene expression rates of this protein were decreased at the time of dissection (it was started after 13 h after landing). At the same time, the content of alpha-actinin-1 decreased in the membranous fraction and increased in the cytoplasmic fraction of proteins from the soleus muscle fibers.

  9. Evidence for Long-period (14-30 Days) and Against Short-period (12-24 Hours) Tidal Modulation of Volcanic Tremor at Arenal Volcano, Costa Rica

    NASA Astrophysics Data System (ADS)

    Hagerty, M. T.; Schwartz, S.; Revenaugh, J.

    2008-12-01

    Many studies have sought a correlation between the occurrence of earthquakes or volcanic activity and various Earth tide components, which would provide evidence for external tidal modulation of these geophysical phenomena. Several studies of short duration seismic experiments at Arenal Volcano in Costa Rica have found evidence of diurnal and semi-diurnal tidal periodicities in the seismic record. However, studies at other volcanoes, using longer time series, with improved spectral resolution, do not find tidal peaks in the seismic spectrum, but rather solar peaks (at exactly 12 and/or 24 hours), suggesting that the modulation is caused not by tidal stresses, but by weather related parameters - temperature, barometric pressure, rainfall. In contrast, recent studies of nonvolcanic tremor in the subduction zones of Japan and Cascadia do find evidence for tidal modulation of tremor activity with a period of 12.4 hours. Thus, the questions of whether or not earthquakes and volcanoes are triggered by external forces, and if so, whether these forces are related to elastic tides or to weather, are still highly relevant. We examine a continuous, 302-day long recording of ground motion at Arenal Volcano, Costa Rica, for potential solar and lunar periodicities in the volcanic seismicity. No evidence is found for significant energy in the semidiurnal (near 12 hr) or diurnal (near 24 hr) frequency bands, in contrast to previous, lower- resolution studies at Arenal. However, analysis with multi-taper method (MTM) and singular spectrum analysis (SSA) reveals significant low-frequency (f < .005 cycles/hr) energy in the tremor and explosivity series, including 14 and 30-day quasi-periodic components, relative to a red noise hypothesis. We attempt to fit the data to long-period tidal frequencies in order to verify potential tidal modulation of the long-period seismic energy at Arenal.

  10. Standard test case for a low-speed, turbulent junction vortex flow

    NASA Technical Reports Server (NTRS)

    Pierce, F. J.

    1991-01-01

    The mean flow structure upstream, around within, and in the near wake of a turbulent junction or horseshoe vortex is reported for an incompressible subsonic flow. Measurements of the primitive variables of velocity and pressure are reported on all surfaces bounding the region of the vortex flow and on three transverse and one streamwise plane within the flowfield itself for comparisons between the measured and any calculated flow variables. Detailed surface flow visualizations and some direct force measurements of surface shear stress are also available. The data is a highly detailed, coherent, self-consistent set offered to the computational fluid mechanics community as a standard test case for the evaluation of the capability of numerical solvers intended for predicting the flowfield in such a complex, separated, three-dimensional turbulent flow. This data base is available for copying to user supplied tapes or for transmission via BITNET, as well as in two National Technical Information Service (NTIS) reports.

  11. Miravalles Geothermal Project: Portable Well Flow Test Equipment and Procedures Manual

    SciTech Connect

    1980-05-01

    The well flow test program has been designed to facilitate the gathering of information, with portable test equipment, from various wells with regard to their capability of flow, the quality of steam produced at various back pressures, the composition and quantity of noncondensable gases flashed from the wells and the composition and quantity of solids in the well's liquid streams (brine). The test program includes procedures for obtaining the following basic flow data pertinent to the plant power cycle design: (1) Effluent steam and brine flows, pressures and temperatures; (2) Noncondensable and dissolved gas contents in steam and brine; (3) H{sub s}S content in gases formed; and (4) Solids content and chemical analysis of steam and brine.

  12. High-resolution Digital Mapping of Historical Lava Flows as a Test-bed for Lava Flow Models

    NASA Astrophysics Data System (ADS)

    Pyle, D. M.; Parks, M.; Nomikou, P.; Mather, T. A.; Simou, E.; Kalnins, L. M.; Paulatto, M.; Watts, A. B.

    2013-12-01

    eruption volume and pre-eruption interval, which will in turn improve our capacity to forecast the size and duration of future dome-forming events at Santorini. The new topographic dataset, and the detailed historical accounts of the eruptions which formed those lava flows, offers a tremendous opportunity to test the current generation of lava flow models.

  13. Water Flow Testing and Unsteady Pressure Analysis of a Two-Bladed Liquid Oxidizer Pump Inducer

    NASA Technical Reports Server (NTRS)

    Schwarz, Jordan B.; Mulder, Andrew; Zoladz, Thomas

    2011-01-01

    The unsteady fluid dynamic performance of a cavitating two-bladed oxidizer turbopump inducer was characterized through sub-scale water flow testing. While testing a novel inlet duct design that included a cavitation suppression groove, unusual high-frequency pressure oscillations were observed. With potential implications for inducer blade loads, these high-frequency components were analyzed extensively in order to understand their origins and impacts to blade loading. Water flow testing provides a technique to determine pump performance without the costs and hazards associated with handling cryogenic propellants. Water has a similar density and Reynolds number to liquid oxygen. In a 70%-scale water flow test, the inducer-only pump performance was evaluated. Over a range of flow rates, the pump inlet pressure was gradually reduced, causing the flow to cavitate near the pump inducer. A nominal, smooth inducer inlet was tested, followed by an inlet duct with a circumferential groove designed to suppress cavitation. A subsequent 52%-scale water flow test in another facility evaluated the combined inducer-impeller pump performance. With the nominal inlet design, the inducer showed traditional cavitation and surge characteristics. Significant bearing loads were created by large side loads on the inducer during synchronous cavitation. The grooved inlet successfully mitigated these loads by greatly reducing synchronous cavitation, however high-frequency pressure oscillations were observed over a range of frequencies. Analytical signal processing techniques showed these oscillations to be created by a rotating, multi-celled train of pressure pulses, and subsequent CFD analysis suggested that such pulses could be created by the interaction of rotating inducer blades with fluid trapped in a cavitation suppression groove. Despite their relatively low amplitude, these high-frequency pressure oscillations posed a design concern due to their sensitivity to flow conditions and

  14. Borehole flowmeter measurements of horizontal groundwater flow before and during an aquifer test in central Indiana

    NASA Astrophysics Data System (ADS)

    Lampe, D. C.

    2009-12-01

    Horizontal borehole flowmeters will be used by the U.S. Geological Survey’s Indiana Water Science Center during an aquifer test in an outwash aquifer adjacent to the White River in central Indiana to determine directions and velocities of horizontal groundwater flow. Borehole flowmeters will provide point measurements of horizontal groundwater flow direction and velocity in four observation wells installed around the producing well. The point flow directions and velocities will be used to evaluate whether the aquifer test induces flow from the direction of nearby hydrologic boundaries: a river, and two adjacent tributaries, and/or from normally upgradient parts of the outwash aquifer system. Final calculations of flow velocity in the formation will include a correction factor based on laboratory flowmeter data. Correction factor data will be collected in the same type of well screen as the observation wells that is emplaced in a laboratory simulator packed with sand from the outwash aquifer and operated at known flow volumes and directions. Flowmeter-based groundwater flow directions and velocities that are made before and during the aquifer test, in combination with recorded water-level fluctuations, will be evaluated to understand groundwater/surface-water interactions and sources of groundwater to the producing well.

  15. Investigation of the Flow-Induced Vibration in the E2 Test Facility

    NASA Technical Reports Server (NTRS)

    Castillo, Luciano

    2001-01-01

    An investigation of flow induced vibration due to coupling between the fluid flow and the propellants lines (LOX and RP-1) was performed. Various flow rate conditions were studied to check whether flow induced vibration was possible due to vortex shedding in both valves and pipe lines. Resonance test was conducted for all segments of the LOX-feedline for the preburner under test. In addition, critical values of frequency and velocity are calculated using a mass damping model. A simple chart characterizing the relation between frequency and velocity is developed for each component; i.e. propellant lines, valves and flow meters. It was found that flow induced vibration occurs for various segments with flow rates of 113 lb/s, 275 lb/s and 40 lb/s. Even more interesting using critical conditions for buckling, it was found that the valve or pipe may collapse for a flow rate of 275 lb/s and valve height of 10% of pipe diameter. Furthermore, two models for the acoustic pressure acting on the segments particularly for the valve are proposed.

  16. Investigation of the Flow-Induced Vibration in the E2 Test Facility

    NASA Technical Reports Server (NTRS)

    Castillo, Luciano

    2001-01-01

    An investigation of flow induced vibration due to coupling between the fluid flow and the propellants lines (LOX and RP-1) was performed. Various flow rate conditions were studied to check whether flow induced vibration was possible due to vortex shedding in both valves and pipe lines. Resonances test was conducted for all segments of the LOX-feedline for the preburner under test. In addition, critical values of frequency and velocity are calculated using a mass damping model. A simple chart characterizing the relation between frequency and velocity is developed for each component; i.e. propellant lines, valves and flow meters. It was found that flow induced vibration occurs for various segments with flow rates of 113 1b/s, 275 lb/s and 40 lb/s. Even more interesting using critical conditions for buckling, it was found that the valve or pipe may collapse for a flow rate of 275 lb/s and valve height of 10% of pipe diameter. Furthermore, two models for the acoustic pressure acting on the segments particularly for the valve are proposed.

  17. Tracer Tests in the Fractured Rock to Investigate Preferential Groundwater Flow

    NASA Astrophysics Data System (ADS)

    Chan, W.; Chung, L.; Lee, T.; Liu, C.; Chia, Y.; Teng, M.

    2012-12-01

    Hydraulic tests are often used to obtain hydraulic conductivity in the aquifer. Test results usually reflect the average hydraulic conductivity in the surrounding strat. However, in fractured rock, groundwater flows primarily through a few fractures. Saltwater tracer test can be used to detect the direction of groundwater flow, but it was difficult to know the hydraulic connectivity between fractures. In this study, we use a variety of field tests, including tracer test, hydraulic test, and heat-pulse flowmeter test, to locate the permeable fractures and detect the hydraulic connections between boreholes. There are eight test wells and two observation wells on field experimental site in central Taiwan. Geological survey results show that there are at least three sets of joint planes. In order to realize the location of the preferential pathway of groundwater flow, heat-pulse flowmeter measurement was adopted to identify the depth of permeable fractures. Multi-well pumping test was also performed to investigate the hydraulic connectivity between these wells. Tracer tests were then used to detect the hydraulic connectivity of permeable fractures between two wells. Injection of nano zero valent iron in one well and and collection of iron tracer with a magnet array in the other well can specifically locate the permeable fracture and determine the connectivity. Saltwater tracer test result can be used to support that of nano-iron tracer test, and verify the relationship between well water conductivity increases and rock fracture location. The results show that tracer test is a useful tool to investigate the preferential groundwater flow in the fractured rock, but it is essential to flush the mud in fractures prior to the test.

  18. Promoted Ignition and Burning Tests of Stainless Steel in Flowing and Nonflowing Oxygen

    NASA Technical Reports Server (NTRS)

    Forsyth, Elliot T.; Maes, Miguel; Stoltzfus, Joel M.; Bachelier, Frederic

    2003-01-01

    The Industry-Sponsored Metals Combustion Test Program 96-1 was coordinated through Wendell Hull & Associates, Inc. on behalf of several contributing companies, and all design and testing was performed at the NASA White Sands Test Facility. Phase I of this test program studied the threshold pressure for self-sustained burning of various types and sizes of stain less steel rods in nonflowing oxygen, as observed in Standard Test Method for Determining the Combustion Behavior of Metallic Materials in Oxygen-Enriched Atmospheres (ASTM G 124-95). Phase II studied the ignition and propagation of burning of 316L stainless steel rods and pipe in flowing gaseous oxygen. The test sample configurations were chosen to replicate previous promoted ignition and burning tests as well as to represent geometries and cross-sectional thicknesses common in industrial piping applications. The gas pressw'es and velocities for the test matrix were selected to generally compare with CGA G-4.4 guidelines for the use of stain less steel in oxygen service. This paper summarizes the results from the Phase I nonflowing oxygen tests and presents in detail the results of the Phase II flowing oxygen tests. The maximum sample burn-length is shown as a function of test pressure in Phase 1 and also as a function of gas velocity in Phase IT. These results indicate that flowing oxygen, under the given test conditions, significantly affects maximum sample burn length as compared to nonflowing oxygen. Supplementary flowing oxygen test data on stainless steel rods from a follow-up test program are consistent with these results and are presented herein.

  19. Evaluation of a Rapid Lateral Flow Point-of-Care Test for Detection of Cryptosporidium

    PubMed Central

    Fleece, Molly E.; Heptinstall, Jack; Khan, Shaila S.; Kabir, Mamum; Herbein, Joel; Haque, Rashidul; Petri, William A.

    2016-01-01

    A new rapid lateral flow fecal antigen detection test for Cryptosporidium was evaluated using diarrheal stool samples from a cohort of children in Bangladesh. The test had a sensitivity of 100% and a specificity of 94% when compared with enzyme-linked immunosorbent assay antigen detection. PMID:27573629

  20. Space Launch System Base Heating Test: Environments and Base Flow Physics

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Knox, Kyle; Seaford, Mark; Dufrene, Aaron

    2016-01-01

    NASA MSFC and CUBRC designed and developed a 2% scale SLS propulsive wind tunnel test program to investigate base flow effects during flight from lift-off to MECO. This type of test program has not been conducted in 40+ years during the NASA Shuttle Program. Dufrene et al paper described the operation, instrumentation type and layout, facility and propulsion performance, test matrix and conditions and some raw results. This paper will focus on the SLS base flow physics and the generation and results of the design environments being used to design the thermal protection system.

  1. Raft River wellfield testing and analysis

    SciTech Connect

    Russell, B.F.

    1982-04-01

    The testing procedures and an overview of the expected performance of the Raft River wellfield during plant operation are presented. Four well-testing procedures were used to evaluate the seven geothermal wells: (1) artesian flow and airlift tests during and shortly after drilling; (2) short duration constant rate and variable-head artesian flow tests following drilling; (3) a series of pulse discharge and injection tests of short duration, with constant rate and variable head; and (4) pumping and injection tests of up to 30 days duration using permanently installed pumps. Productivity curves were plotted for each of the exploratory and production wells. It was concluded that the Raft River wellfield has the capability of supplying the necessary flow to operate the 5MW(e) facility. (MJF)

  2. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    NASA Technical Reports Server (NTRS)

    Forbes, John C.; Xenofos, George D.; Farrow, John L.; Tyler, Tom; Williams, Robert; Sargent, Scott; Moharos, Jozsef

    2004-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a full-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrumentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors.

  3. Closed-loop flow test Miravalles Geothermal Field well log results

    SciTech Connect

    Dennis, B.; Eden, G.; Lawton, R.

    1992-10-01

    The Instituto Costarricense de Electricidad (ICE) conducted a closed-loop flow test in the Miravalles Geothermal Field. The closed-loop test was started in May and ran through August of 1990. The effluent from the production well PG-11 was carried by a pipeline through a monitor station to the injection well PG-2. Before starting the long-term flow test in May, cold-water injection experiments were performed in each well to determine the pressure and temperature response. A series of downhole measurements were made in each well to obtain background information. The downhole measurements were repeated in August just before terminating the flow test to evaluate the results.

  4. Closed-loop flow test Miravalles Geothermal Field well log results

    SciTech Connect

    Dennis, B.; Eden, G.; Lawton, R.

    1992-01-01

    The Instituto Costarricense de Electricidad (ICE) conducted a closed-loop flow test in the Miravalles Geothermal Field. The closed-loop test was started in May and ran through August of 1990. The effluent from the production well PG-11 was carried by a pipeline through a monitor station to the injection well PG-2. Before starting the long-term flow test in May, cold-water injection experiments were performed in each well to determine the pressure and temperature response. A series of downhole measurements were made in each well to obtain background information. The downhole measurements were repeated in August just before terminating the flow test to evaluate the results.

  5. Mechanical properties of non-sarcomeric cytoskeleton of mice cardiomyocytes and skeletal muscle fibers after 30-day spaceflight biosatellite BION-M1

    NASA Astrophysics Data System (ADS)

    Ogneva, Irina; Maximova, Maria; Larina, Irina

    The aim of this study was to determine transversal stiffness of the cortical cytoskeleton and cytoskeletal protein desmin content of the left ventricle cardiomyocytes, soleus and tibialis anterior muscle fibers of the mice after 30-days space flight biosatellite «BION-M1» (Russia, 2013). The dissection was made after 13-16.5 hours after landing. Transversal stiffness was measured in relaxed and calcium activated state by atomic force microscope. Desmin content was estimated by using western-blot, expression level of the gene, coding desmin, - by real time PCR. The transversal stiffness of the cortical cytoskeleton of the cardiomyocytes and fibers of the skeletal muscles (as measured using the atomic force microscopy) did not differ significantly within the study groups in comparison to the vivarium control group, except for its slight increase in tibialis anterior fibers muscle in the post-flight group of animals. The content of beta- and gamma-actin in the membranous fraction of proteins in the left ventricular cardiomyocytes (as detected using the western blot technique) did not differ significantly within all study groups and correlated with the transversal stiffness. Similar situation was revealed in fibers of the soleus muscle and tibialis anterior muscle, as well as correlation with the transversal stiffness of their cortical cytoskeleton was noted. At the same time, the content of beta-actin in the cytoplasmic fraction of proteins was found to be decreased in all types of studied tissues in comparison to the control levels in the post-flight group, as well as lowered beta-actin gene expression rates in the post-flight group of animals (as detected using the RT-PCR technique). After completion of the space flight, content of alpha-actinin-4 was found to be reduced in the membranous fraction of proteins of mouse cardiomyocytes, while its content in the cytoplasmic fraction of proteins did not change significantly. Furthermore, gene expression rates of this

  6. Are weekend inpatient rehabilitation services value for money? An economic evaluation alongside a randomized controlled trial with a 30 day follow up

    PubMed Central

    2014-01-01

    Background Providing additional Saturday rehabilitation can improve functional independence and health related quality of life at discharge and it may reduce patient length of stay, yet the economic implications are not known. The aim of this study was to determine from a health service perspective if the provision of rehabilitation to inpatients on a Saturday in addition to Monday to Friday was cost effective compared to Monday to Friday rehabilitation alone. Methods Cost utility and cost effectiveness analyses were undertaken alongside a multi-center, single-blind randomized controlled trial with a 30-day follow up after discharge. Participants were adults admitted for inpatient rehabilitation in two publicly funded metropolitan rehabilitation facilities. The control group received usual care rehabilitation services from Monday to Friday and the intervention group received usual care plus an additional rehabilitation service on Saturday. Incremental cost utility ratio was reported as cost per quality adjusted life year (QALY) gained and an incremental cost effectiveness ratio (ICER) was reported as cost for a minimal clinically important difference (MCID) in functional independence. Results 996 patients (mean age 74 (standard deviation 13) years) were randomly assigned to the intervention (n = 496) or the control group (n = 500). Mean difference in cost of AUD$1,673 (95% confidence interval (CI) -271 to 3,618) was a saving in favor of the intervention group. The incremental cost utility ratio found a saving of AUD$41,825 (95% CI -2,817 to 74,620) per QALY gained for the intervention group. The ICER found a saving of AUD$16,003 (95% CI -3,074 to 87,361) in achieving a MCID in functional independence for the intervention group. If the willingness to pay per QALY gained or for a MCID in functional independence was zero dollars the probability of the intervention being cost effective was 96% and 95%, respectively. A sensitivity analysis removing Saturday

  7. Characteristics and Preliminary Observations of the Influence of Electromyostimulation on the Size and Function of Human Skeletal Muscle During 30 Days of Simulated Microgravity

    NASA Technical Reports Server (NTRS)

    Duvoisin, Marc R.; Convertino, Victor A; Buchanan, Paul; Gollinick, Philip D.; Dudley, Gary A.

    1989-01-01

    During 30 days (d) of bedrest, the practicality of using Elec- troMyoStimulation (EMS) as a deterrent to atrophy and strength loss of lower limb musculature was examined. An EMS system was developed that provided variable but quantifiable levels of EMS, and measured torque. The dominant log of three male subjects was stimulated twice daily in a 3-d on/1-d off cycle during bedrest. The non-dominant leg of each subject acted as a control. A stimulator, using a 0.3 ms monophasic 60 Hz pulse waveform, activated muscle tissue for 4 s. The output waveform from the stimulator was sequenced to the Knee Extensors (KE), Knee Flex- ors (KF), Ankle Extensors (AE), and Ankle Flexors (AF), and caused three isometric contractions of each muscle group per minute. Subject tolerance determined EMS Intensity. Each muscle group received four 5-min bouts of EMS each session with a 10 -min rest between bouts. EMS and torque levels for each muscle action were recorded directly an a computer. Overall average EMS Intensity was 197, 197, 195, and 188 mA for the KE, KF, AF, and AE, respectively. Overall average torque development for these muscle groups was 70, 16, 12, and 27 Nm, respectively. EMS intensity doubled during the study, and average torque increased 2.5 times. Average maximum torque throughout a session reached 54% of maximal voluntary for the KE and 29% for the KF. Reductions in leg volume, muscle compartment size, cross-sectional area of slow and fast-twitch fibers, strength, and aerobic enzyme activities, and increased log compliance were attenuated in the legs which received EMS during bedrest. These results indicate that similar EMS levels induce different torques among different muscle groups and that repeated exposure to EMS increases tolerance and torque development. Longer orien- tation periods, therefore, may enhance its effectiveness. Our preliminary data suggest that the efficacy of EMS as an effective countermeasure for muscle atrophy and strength loss during long

  8. Pre-test estimates of temperature decline for the LANL Fenton Hill Long-Term Flow Test

    SciTech Connect

    Robinson, B.A.; Kruger, P.

    1992-06-01

    Pre-test predications for the Long-Term Flow Test (LTFT) of the experimental Hot Dry Rock (HDR) reservoir at Fenton Hill were made using two models. Both models are dependent on estimates of the ``effective`` reservoir volume accessed by the fluid and the mean fracture spacing (MFS) of major joints for fluid flow. The effective reservoir volume was estimated using a variety of techniques, and the range of values for the MFS was set through experience in modeling the thermal cooldown of other experimental HDR reservoirs. The two pre-test predictions for cooldown to 210{degrees}C (a value taken to compare the models) from initial temperature of 240{degrees}C are 6.1 and 10.7 years. Assuming that a minimum of 10{degrees}C is required to provide an unequivocal indication of thermal cooldown, both models predict that the reservoir will not exhibit observable cooldown for at least two years.

  9. Report on the testing of the no-flow push bit

    SciTech Connect

    Witwer, K.S.

    1996-10-09

    Testing was carried out in the Engineering Testing Laboratory, 305 Building- 300 Area, during June, July and August of 1996. This testing was to develop and proof test a new sampler insert which would prevent purge gas from flowing through a push-mode core drilling bit - and subsequently prevent rotation of the Rotary Mode Core Sampling System (RMCSS) when the push bit was used. The testing involved push-mode sampling with both a new push mode insert and a rotary insert in a push mode bit into two simulants. A total of sixty final test runs showed that the inserts are sucessful in preventing purge flow and hence in preventing rotation with a push-mode bit installed.

  10. Test Data of Flow Field of Shuttle SRM Nozzle Joint with Bond Defects, Using Unheated Air

    NASA Technical Reports Server (NTRS)

    Hair, Leroy M.; McAnally, James V.; Hengel, John E.

    1989-01-01

    The nozzle-to-case joint on the Shuttle SRM (as redesigned after the Challenger accident) features an adhesive sealant filling and bonding the joint, with a wiper O-ring to prevent the adhesive from reaching and disabling the closure O-ring. Flawless implementation of that joint design would ensure that hot, corrosive propellant combustion gases never reach the closure O-ring. However, understanding the flow field related to bonding defects is prudent. A comprehensive test program was conducted to quantify such flow fields and associated heating environments. A two-dimensional, full-scale model represented 65 inches of the nozzle joint, using unheated air as the test medium, in a blowdown mode. Geometry variations modeled RSRM assembly tolerances, and two types of bonding defects: pullaways and blowholes. A range of the magnitude of each type defect was tested. Also a range of operational parameters was tested, representative of the RSRM flow environment, including duplication of RSRM Mach and Reynolds numbers. Extensive instrumentation was provided to quantify pressures, heat rates, and velocities. The resulting data established that larger geometric defects cause larger pressure and larger heating, at the closure O-ring region. Velocity trends were not so straight-forward. Variations in assembly tolerances did not generally affect flow fields or heating. Operational parameters affected flow fields and heating as might be expected, increasing density or velocity increased heating. Complete details of this test effort are presented.

  11. Development of a robust procedure for assessing powder flow using a commercial avalanche testing instrument.

    PubMed

    Hancock, Bruno C; Vukovinsky, Kim E; Brolley, Barry; Grimsey, Ian; Hedden, David; Olsofsky, Angela; Doherty, Rebecca A

    2004-09-01

    The objectives of this work were to develop a robust procedure for assessing powder flow using a commercial avalanche testing instrument and to define the limits of its performance. To achieve this a series of powdered pharmaceutical excipients with a wide range of flow properties was characterized using such an instrument (Aeroflow, TSI Inc., St. Paul, MN, USA). The experimental conditions (e.g., sample size, rotation speed) were rationally selected and systematically evaluated so that an optimal standard-operating-procedure could be identified. To evaluate the inherent variability of the proposed methodology samples were tested at multiple sites, using different instruments and operators. The ranking of the flow properties of the powders obtained was also compared with that obtained using a conventional shear-cell test. As a result of these experiments a quick, simple, and rugged procedure for determining the flow properties of pharmaceutical powders in their dilated state was developed. This procedure gave comparable results when performed at four different testing sites and was able to reproducibly rank the flow properties of a series of common pharmaceutical excipient powders. The limits of the test method to discriminate between different powder samples were determined, and a positive correlation with the results of a benchmark method (the simplified shear cell) was obtained.

  12. Flight test and numerical simulation of transonic flow around YAV-8B Harrier II wing

    NASA Technical Reports Server (NTRS)

    Gea, Lie-Mine; Chyu, Wei J.; Stortz, Michael W.; Roberts, Andrew C.; Chow, Chuen-Yen

    1991-01-01

    A computational fluid dynamics (CFD) method is used to study the aerodynamics of the YAV-8B Harrier II wing in the transonic region. A numerical procedure is developed to compute the flow field around the complicated wing-pylon-fairing geometry. The surface definition of the wing and pylons were obtained from direct measurement using theodolite triangulation. A thin-layer Navier-Stokes code with the Chimera technique is used to compute flow solutions. The computed pressure distributions at several span stations are compared with flight test data and show good agreement. Computed results are correlated with flight test data that show the flow is severely separated in the vicinity of the wing-pylon junction. Analysis shows that shock waves are induced by pylon swaybrace fairings, that the flow separation is much stronger at the outboard pylon and that the separation is caused mainly by the crossflow passing the geometry of wing-pylon junction.

  13. Wind Tunnel Test Results for Gas Flows Inside Axisymmetric Cavities on Cylindric Bodies with Nose Cones

    NASA Technical Reports Server (NTRS)

    Shvets, A. L.; Gilinsky, M.; Blankson, I. M.

    2004-01-01

    Experimental test results of air flow inside and at the cylindrical cavity located on axisymmetric body are presented. These tests were conducted in the wind tunnel A-7 of Institute of Mechanics at Moscow State University. Pressure distribution along the cavities and optical measurements were obtained. Dependence of these characteristics of length of a cavity in the range: L/D = 0.5 - 14 and free stream Mach in the range: M(sub infinity) = 0.6 - 3.0 was determined. Flow structure inside the cavity, cause of flow regime change, separation zones geometry and others were studied. In particular, the flow modes of with open and closed separation zones are determined.

  14. Results mixed from pulsating flow tests of orifice-plate meters

    SciTech Connect

    Arasi, J.A. )

    1992-10-05

    This paper reports that laboratory tests on several commercially available orifice-plate meters for use in pulsating flow indicate that none yields acceptable accuracy. These tests suggested, however, that if the objective of monitoring pulsating flow is to indicate or quantify pulsation magnitudes for comparisons, then at least two instruments are acceptable. Use of such meters, particularly in low flow rate gathering systems, can be a viable alternative to attempting to reduce the intensity (amplitude and frequency) of pulsation by expensive installation and maintenance of chokes and bottles. Phillips Petroleum Co. set out to find a meter that would be sensitive enough to measure pulsating hydrocarbon flows with acceptable accuracy using the orifice plate. Several orifice measurement systems were simultaneously investigated at the Southwest Research Institute, San Antonio (SwRI).

  15. SRM Internal Flow Tests and Computational Fluid Dynamic Analysis. Volume 4; Cold Flow Analyses and CFD Analysis Capability Development

    NASA Technical Reports Server (NTRS)

    1995-01-01

    An evaluation of the effect of model inlet air temperature drift during a test run was performed to aid in the decision on the need for and/or the schedule for including heaters in the SRMAFTE. The Sverdrup acceptance test data was used to determine the drift in air temperature during runs over the entire range of delivered flow rates and pressures. The effect of this temperature drift on the model Reynolds number was also calculated. It was concluded from this study that a 2% change in absolute temperature during a test run could be adequately accounted for by the data analysis program. A handout package of these results was prepared and presented to ED35 management.

  16. Construction and demolition waste: Comparison of standard up-flow column and down-flow lysimeter leaching tests.

    PubMed

    Butera, Stefania; Hyks, Jiri; Christensen, Thomas H; Astrup, Thomas F

    2015-09-01

    Five samples of construction and demolition waste (C&DW) were investigated in order to quantify leaching of inorganic elements under percolation conditions according to two different experimental setups: standardised up-flow saturated columns (<4mm particle size) and unsaturated, intermittent down-flow lysimeters (<40mm particle size). While standardised column tests are meant primarily to provide basic information on characteristic leaching properties and mechanisms and not to reproduce field conditions, the lysimeters were intended to mimic the actual leaching conditions when C&DW is used in unbound geotechnical layers. In practice, results from standardised percolation tests are often interpreted as estimations of actual release from solid materials in percolation scenarios. In general, the two tests yielded fairly similar results in terms of cumulative release at liquid-to-solid ratio (L/S) 10l·kgTS; however, significant differences were observed for P, Pb, Ba, Mg and Zn. Further differences emerged in terms of concentration in the early eluates (L/S<5l·kg(-1)TS) for Al, As, Ba, Cd, Cu, DOC, Mg, Mn, Ni, P, Pb, Sb, Se, Si, Zn. Observed differences between tests are likely to be due to differences in pH related to crushing and exposure of fresh particle surfaces, as well as in equilibrium conditions. In the case of C&DW, the standardised column tests, which are more practical, are considered to acceptably describe cumulative releases at L/S 10l·kg(-1)TS in percolation scenarios. However, when the focus is on estimation of initial concentrations for (for example) risk assessment, data from standardised column tests may not be fully applicable, and data from lysimeters may be used for validation purposes. Se, Cr and, to a lesser extent, SO4 and Sb were leaching from C&DW in critical amounts compared with existing limit values. PMID:26031330

  17. Research on optical fiber flow test method with non-intrusion

    NASA Astrophysics Data System (ADS)

    Shang, Ying; Liu, Xiaohui; Wang, Chang; Zhao, Wenan

    2014-06-01

    In the field of oil well logging, real-time monitoring of the fluid flow parameter provides a scientific basis for oil and gas optimization exploration and increase in reservoir recovery, so a non-intrusive flow test method based on turbulent vibration was proposed. The specific length of the sensor fiber wound tightly around the outer wall of the pipe was connected with the optical fiber gratings at both ends, and the sensor fiber and the optical fiber gratings composed the flow sensing unit. The dynamic pressure was generated by the turbulence when fluid flows through the pipe, and the dynamic pressure resulted in the light phase shift of the sensor fiber. The phase information was demodulated by the fiber optic interferometer technology, time division multiplexing technology, and phase generated carrier modulation and demodulation techniques. The quadratic curve relationship between the phase change and flow rate was found by experimental data analysis, and the experiment confirmed the feasibility of the optical fiber flow test method with non-intrusion and achieved the real-time monitoring of the fluid flow.

  18. Flow tests of a single fuel element coolant channel for a compact fast reactor for space power

    NASA Technical Reports Server (NTRS)

    Springborn, R. H.

    1971-01-01

    Water flow tests were conducted on a single-fuel-element cooling channel for a nuclear concept to be used for space power. The tests established a method for measuring coolant flow rate which is applicable to water flow testing of a complete mockup of the reference reactor. The inlet plenum-to-outlet plenum pressure drop, which approximates the overall core pressure drop, was measured and correlated with flow rate. This information can be used for reactor coolant flow and heat transfer calculations. An analytical study of the flow characteristics was also conducted.

  19. Fluid Structure Interaction in a Cold Flow Test and Transient CFD Analysis of Out-of-Round Nozzles

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph; Brown, Andrew; McDaniels, David; Wang, Ten-See

    2010-01-01

    This viewgraph presentation describes two nozzle fluid flow interactions. They include: 1) Cold flow nozzle tests with fluid-structure interaction at nozzle separated flow; and 2) CFD analysis for nozzle flow and side loads of nozzle extensions with various out-of-round cases.

  20. Effect of flow leakage on the benchmarking of FLOWTRAN with Mark-22 mockup flow excursion test data from Babcock and Wilcox

    SciTech Connect

    Chen, Kuo-Fu.

    1992-10-01

    This report presents a revised analysis of the Babcock and Wilcox (B and W) downflow flow excursion tests that accounts for leakage between flow channels in the test assembly. Leak rates were estimated by comparing results from the downflow tests with those for upflow tests conducted using an identical assembly with some minor modifications. The upflow test assembly did not contain leaks. This revised analyses shows that FLOWTRAN with the SRS working criterion conservatively predicts onset of flow instability without using a local peaking factor to model heat transfer variations near the ribs.

  1. Seismic monitoring of the June, 1988 Salton Sea Scientific Drilling Program flow/injection test

    SciTech Connect

    Jarpe, S.P.; Kasameyer, P.W.; Hutchings, L.J.; Hauk, T.F.

    1988-10-04

    The purpose of the seismic monitoring project was to characterize in detail the micro-seismic activity related to the Salton Sea Scientific Drilling Program (SSSDP) flow-injection test in the Salton Sea Geothermal Field. Our goal was to determine if any sources of seismic energy related to the test were observable at the surface. We deployed our recording stations so that we could detect and locate both impulsive microearthquakes and continuous seismic noise energy. Our network, which was sensitive enough to be triggered by magnitude 0.0 or larger events, found no impulsive microearthquakes in the vicinity of the flow test in the 8 month period before the test and only one event during the flow test. This event has provided the opportunity to compare the detection and location capabilities of small networks and arrays in a geothermal environment. At present, we are carefully scanning all of the data that we collected during the flow test for evidence of anomalous seismic noise sources and for impulsive events smaller than the network detection threshold (magnitude 0.0). 8 refs., 4 figs.

  2. Characterization Of Flow Stress Of Different AA6082 Alloys By Means Of Hot Torsion Test

    SciTech Connect

    Donati, Lorenzo; El Mehtedi, Mohamad

    2011-05-04

    FEM simulations are become the most powerful tools in order to optimize the different aspects of the extrusion process and an accurate flow stress definition of the alloy is a prerequisite for a reliable effectiveness of the simulation. In the paper the determination of flow stress by means of hot torsion test is initially presented and discussed: the several approximations that are usually introduced in flow stress computation are described and computed for an AA6082 alloy in order to evidence the final effect on curves shapes. The procedure for regressing the parameters of the sinhyperbolic flow stress definition is described in detailed and applied to the described results. Then four different alloys, extracted by different casting batches but all namely belonging to the 6082 class, were hot torsion tested in comparable levels of temperature and strain rate up to specimen failure. The results are analyzed and discussed in order to understand if a mean flow stress behavior can be identified for the whole material class at the different tested conditions or if specific testing conditions (chemical composition of the alloy, specimen shape, etc) influence the materials properties to a higher degree.

  3. Continuous-flow stirred-tank reactor 20-L demonstration test: Final report

    SciTech Connect

    Lee, D.D.; Collins, J.L.

    2000-02-01

    One of the proposed methods of removing the cesium, strontium, and transuranics from the radioactive waste storage tanks at Savannah River is the small-tank tetraphenylborate (TPB) precipitation process. A two-reactor-in-series (15-L working volume each) continuous-flow stirred-tank reactor (CSTR) system was designed, constructed, and installed in a hot cell to test the Savannah River process. The system also includes two cross-flow filtration systems to concentrate and wash the slurry produced in the process, which contains the bulk of radioactivity from the supernatant processed through the system. Installation, operational readiness reviews, and system preparation and testing were completed. The first test using the filtration systems, two CSTRs, and the slurry concentration system was conducted over a 61-h period with design removal of Cs, Sr, and U achieved. With the successful completion of Test 1a, the following tests, 1b and 1c, were not required.

  4. Changing cerebral blood flow in normal pressure hydrocephalus after the tap test can predict clinical improvement

    PubMed Central

    Sedighi, Behnaz; Shafiee, Kaveh; Seifaldini, Rostam; Abdi, As'ad

    2014-01-01

    Background: We studied the role of cerebrospinal fluid (CSF) tap test at idiopathic normal pressure hydrocephalus (INPH) in improving cerebral blood flow velocity indices by transcranial Doppler (TCD) sonography. Methods: Twelve patients with assumed INPH were included in the study. The CSF tap test and INPH grading score was carried out according to the standard protocol. TCD was performed before and after the tap test for assessing blood flow in middle cerebral and anterior cerebral arteries. Results: Five INPH patients (41.7%) had clinical improvement as defined by at least one point reduction in INPH grading scale. The baseline TCD parameters of the middle cerebral artery were significantly higher compared with the control, and those parameters were decreased after tap test in those who improved. Conclusion: Our study showed that improvement in INPH grading score after CSF tap test might correlate with changing in TCD parameter in MCA and TCD parameter might be useful for shunt response in these patients. PMID:25632339

  5. Underground Test Area Subproject Phase I Data Analysis Task. Volume VI - Groundwater Flow Model Documentation Package

    SciTech Connect

    1996-11-01

    Volume VI of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the groundwater flow model data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

  6. Test Outline for Flutter Analysis of Rectangular Panels in Rarefied Flow Conditions

    NASA Technical Reports Server (NTRS)

    Akl, Fred A.

    1996-01-01

    Jet plume impingement forces acting on large flexible space structures may precipitate dynamically unstable behavior during space flights. Typical operating conditions in space involve rarefied gas flow regimes which are intrinsically distinct from continuum gas flow and are normally modeled using the kinetic theory of gas flow. Docking and undocking operations of the Space Shuttle with the Russian Mir space laboratory represent a scenario in which the stability boundaries of solar panels may be of interest. Extensive literature review of research work on the dynamic stability of rectangular panels in rarefied gas flow conditions indicated the lack of published reports dealing with this phenomenon. A recently completed preliminary study for NASA JSC dealing with the mathematical analysis of the stability of two-degree-of-freedom elastically supported rigid panels under the effect of rarefied gas flow was reviewed. A test plan outline is prepared for the purpose of conducting a series of experiments on four rectangular rigid test articles in a vacuum chamber under the effect of continuous and pulsating Nitrogen jet plumes. The purpose of the test plan is to gather enough data related to a number of key parameters to allow the validation of the two-degree-of-freedom mathematical model. The hardware required careful design to select a very lightweight material while satisfying rigidity and frequency requirements within the constraints of the test environment. The data to be obtained from the vacuum chamber tests can be compared with the predicted behavior of the theoretical two-degree-of-freedom model. Using the data obtained in this study, further research can identify the limitations of the mathematical model. In addition modifications to the mathematical model can be made, if warranted, to accurately predict the behavior of rigid panels under rarefied gas flow regimes.

  7. Nanoscale Capillary Flows in Alumina: Testing the Limits of Classical Theory.

    PubMed

    Lei, Wenwen; McKenzie, David R

    2016-07-21

    Anodic aluminum oxide (AAO) membranes have well-formed cylindrical channels, as small as 10 nm in diameter, in a close packed hexagonal array. The channels in AAO membranes simulate very small leaks that may be present for example in an aluminum oxide device encapsulation. The 10 nm alumina channel is the smallest that has been studied to date for its moisture flow properties and provides a stringent test of classical capillary theory. We measure the rate at which moisture penetrates channels with diameters in the range of 10 to 120 nm with moist air present at 1 atm on one side and dry air at the same total pressure on the other. We extend classical theory for water leak rates at high humidities by allowing for variable meniscus curvature at the entrance and show that the extended theory explains why the flow increases greatly when capillary filling occurs and enables the contact angle to be determined. At low humidities our measurements for air-filled channels agree well with theory for the interdiffusive flow of water vapor in air. The flow rate of water-filled channels is one order of magnitude less than expected from classical capillary filling theory and is coincidentally equal to the helium flow rate, validating the use of helium leak testing for evaluating moisture flows in aluminum oxide leaks. PMID:27336652

  8. Testing geodynamic models of lowermost mantle flow with a regional shear wave splitting data set

    NASA Astrophysics Data System (ADS)

    Ford, H. A.; Long, M. D.

    2015-12-01

    Global flow models rely on a number of assumptions, including composition, temperature, viscosity, and deformation mechanism. In the upper mantle, flow models and their associated assumptions can be tested and refined with observations of seismic anisotropy, which is treated as a proxy for flow direction. Beneath the transition zone, direct observations of seismic anisotropy are scarce, except for in the lowermost ~250 km of the mantle. In this study, we utilize a comprehensive, previously published (Ford et al., 2015) shear wave splitting study in order to test a three-dimensional global geodynamic flow model (Walker et al., 2011). Our study focuses on a region of the lowermost mantle along the eastern edge of the African Superplume beneath the Afar region. We find that our observations are fit by a model which invokes slip along the (010) plane of post-perovskite with flow directed down and to the southwest. Critically, we demonstrate the ability of a regional data set to interrogate models of lower mantle flow.

  9. Ultra high bypass Nacelle aerodynamics inlet flow-through high angle of attack distortion test

    NASA Technical Reports Server (NTRS)

    Larkin, Michael J.; Schweiger, Paul S.

    1992-01-01

    A flow-through inlet test program was conducted to evaluate inlet test methods and determine the impact of the fan on inlet separation when operating at large angles of attack. A total of 16 model configurations of approximately 1/6 scale were tested. A comparison of these flow-through results with powered data indicates the presence of the fan increased separation operation 3 degrees to 4 degrees over the flow through inlet. Rods and screens located at the fan face station, that redistribute the flow, achieved simulation of the powered-fan results for separation angle of attack. Concepts to reduce inlet distortion and increase angle of attack capability were also evaluated. Vortex generators located on the inlet surface increased inlet angle of attack capability up to 2 degrees and reduced inlet distortion in the separated region. Finally, a method of simulating the fan/inlet aerodynamic interaction using blockage sizing method has been defined. With this method, a static blockage device used with a flow-through model will approximate the same inlet onset of separation angle of attack and distortion pattern that would be obtained with an inlet model containing a powered fan.

  10. Forced Flow Flame Spreading Test: Preliminary Findings From the USMP-3 Shuttle Mission

    NASA Technical Reports Server (NTRS)

    Sacksteder, Kurt R.; Greenberg, Paul S.; Pettegrew, Richard D.; Tien, James S.; Ferkul, Paul V.; Shih, Hsin-Yi

    1998-01-01

    The Forced Flow Flame spreading Test (FFFT) is a study of flame spreading over solid fuels in very low-speed air flows. The FFFT experiment is part of research entitled Solid Inflammability Boundary at Low Speeds, (SIBAL) intended for operations on the Space Station. In the FFFT experiment, a series of 15 experiments conducted aboard the space shuttle during the United States Microgravity Payload (USMP-3) mission provided information about the structure and spreading characteristics of flames in low-speed, concurrent flows. The test samples included flat sheets of cellulose and cast cylinders of cellulose, burned in air at velocities of approximately 1 to 8 cm/sec. The test results have been successfully compared to theoretical predictions of the SIBAL program, a fundamentally based numerical simulation of concurrent flow flame spread. Additionally, some guidance for the design characteristics of the SIBAL flight experiment have been obtained including some verification of the theoretical predictions of flame size versus the required size of the SIBAL flow duct, and the effect of the presence of thermocouples in the vicinity of near-limit flames in microgravity.

  11. Flow in a discrete slotted nozzle with massive injection. [water table tests

    NASA Technical Reports Server (NTRS)

    Perkins, H. C.

    1974-01-01

    An experimental investigation has been conducted to determine the effect of massive wall injection on the flow characteristics in a slotted nozzle. Some of the experiments were performed on a water table with a slotted-nozzle test section. This has 45 deg and 15 deg half angles of convergence and divergence, respectively, throat radius of 2.5 inches, and throat width of 3 inches. The hydraulic analogy was employed to qualitatively extend the results to a compressible gas flow through the nozzle. Experimental results from the water table include contours of constant Froude and Mach number with and without injection. Photographic results are also presented for the injection through slots of CO2 and Freon-12 into a main-stream air flow in a convergent-divergent nozzle in a wind tunnel. Schlieren photographs were used to visualize the flow, and qualititative agreement between the results from the gas tunnel and water table is good.

  12. Design, testing, and model validation of an MR squeeze-flow vibration damper

    NASA Astrophysics Data System (ADS)

    Sims, Neil D.; Stanway, Roger; Johnson, Andrew R.; Mellor, Phillip

    2001-07-01

    Ongoing research at the University of Sheffield is currently concerned with the design and construction of magneto- rheological (MR) squeeze-flow vibration damper. Previous work has demonstrated the feasibility of employing such a device as the key component in a controllable vibration isolator. The work also demonstrated the inadequacies of existing mathematical models which do not account for the observed behavior of MR fluids in squeeze flow. In parallel with investigations into the behavior of MR dampers, a collaborative programme between the Universities of Liverpool and Sheffield is also in progress. Here attention is focussed on ER fluids in squeeze-flow and a new test facility has been constructed for use in the development and validation of mathematical models. It is anticipated that this collaborative programme will assist in the development of both ER and MR squeeze-flow models. In this paper, the authors present a summary of progress to date.

  13. Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

    SciTech Connect

    Ballinger, Marcel Y.; Glissmeyer, John A.; Barnett, J. Matthew; Recknagle, Kurtis P.; Yokuda, Satoru T.

    2011-05-31

    The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests

  14. Study and application of a high-pressure water jet multi-functional flow test system.

    PubMed

    Shi, Huaizhong; Li, Gensheng; Huang, Zhongwei; Li, Jingbin; Zhang, Yi

    2015-12-01

    As the exploration and development of oil and gas focus more and more on deeper formation, hydraulic issues such as high-pressure water jet rock breaking, wellbore multiphase flow law, cuttings carrying efficiency, and hydraulic fracturing technique during the drilling and completion process have become the key points. To accomplish related researches, a high-pressure water jet multi-functional flow test system was designed. The following novel researches are carried out: study of high-pressure water jet characteristics under confining pressure, wellbore multiphase flow regime, hydraulic pressure properties of down hole tools during jet fracturing and pulsed cavitation jet drilling, and deflector's friction in radial jet drilling. The validity and feasibility of the experimental results provided by the system with various test modules have proved its importance in the research of the high-pressure water jet and well completion technology. PMID:26724077

  15. Model-Invariant Hybrid Computations of Separated Flows for RCA Standard Test Cases

    NASA Technical Reports Server (NTRS)

    Woodruff, Stephen

    2016-01-01

    NASA's Revolutionary Computational Aerosciences (RCA) subproject has identified several smooth-body separated flows as standard test cases to emphasize the challenge these flows present for computational methods and their importance to the aerospace community. Results of computations of two of these test cases, the NASA hump and the FAITH experiment, are presented. The computations were performed with the model-invariant hybrid LES-RANS formulation, implemented in the NASA code VULCAN-CFD. The model- invariant formulation employs gradual LES-RANS transitions and compensation for model variation to provide more accurate and efficient hybrid computations. Comparisons revealed that the LES-RANS transitions employed in these computations were sufficiently gradual that the compensating terms were unnecessary. Agreement with experiment was achieved only after reducing the turbulent viscosity to mitigate the effect of numerical dissipation. The stream-wise evolution of peak Reynolds shear stress was employed as a measure of turbulence dynamics in separated flows useful for evaluating computations.

  16. Fiber Bragg grating tether used to measure drag forces in neutral buoyancy flow tank tests.

    PubMed

    Wade, S A; Jolley, W; Fouras, A

    2008-06-01

    The drag exerted on neutrally buoyant tethered spheres in a flow tank was measured as a function of flow rate. A unique solution to the problem was achieved using an optical fiber including a Bragg grating sensor as part of the tether. Measurements of the strain on the tether taken at flow rates between 0.14 and 0.33 m/s, were used to determine drag forces for spheres with diameters ranging from 40 to 100 mm. Vortex-induced vibration was observed in tests performed at Reynolds numbers from 5 x 10(3) to 4.5 x 10(4). The drag coefficients for these tests were found to range from 0.51 to 0.77.

  17. Study and application of a high-pressure water jet multi-functional flow test system.

    PubMed

    Shi, Huaizhong; Li, Gensheng; Huang, Zhongwei; Li, Jingbin; Zhang, Yi

    2015-12-01

    As the exploration and development of oil and gas focus more and more on deeper formation, hydraulic issues such as high-pressure water jet rock breaking, wellbore multiphase flow law, cuttings carrying efficiency, and hydraulic fracturing technique during the drilling and completion process have become the key points. To accomplish related researches, a high-pressure water jet multi-functional flow test system was designed. The following novel researches are carried out: study of high-pressure water jet characteristics under confining pressure, wellbore multiphase flow regime, hydraulic pressure properties of down hole tools during jet fracturing and pulsed cavitation jet drilling, and deflector's friction in radial jet drilling. The validity and feasibility of the experimental results provided by the system with various test modules have proved its importance in the research of the high-pressure water jet and well completion technology.

  18. Study and application of a high-pressure water jet multi-functional flow test system

    NASA Astrophysics Data System (ADS)

    Shi, Huaizhong; Li, Gensheng; Huang, Zhongwei; Li, Jingbin; Zhang, Yi

    2015-12-01

    As the exploration and development of oil and gas focus more and more on deeper formation, hydraulic issues such as high-pressure water jet rock breaking, wellbore multiphase flow law, cuttings carrying efficiency, and hydraulic fracturing technique during the drilling and completion process have become the key points. To accomplish related researches, a high-pressure water jet multi-functional flow test system was designed. The following novel researches are carried out: study of high-pressure water jet characteristics under confining pressure, wellbore multiphase flow regime, hydraulic pressure properties of down hole tools during jet fracturing and pulsed cavitation jet drilling, and deflector's friction in radial jet drilling. The validity and feasibility of the experimental results provided by the system with various test modules have proved its importance in the research of the high-pressure water jet and well completion technology.

  19. Characterization of scale-dependent dispersivity in fractured formations through a divergent flow tracer test.

    PubMed

    Sharifi Haddad, Amin; Hassanzadeh, Hassan; Abedi, Jalal; Chen, Zhangxin; Ware, Antony

    2015-04-01

    Scale-dependency of dispersivity has been reported from field tracer tests. We present a simple methodology for characterization of dispersivity as a linear function of scale around an injection well using divergent flow tracer test data conducted in fractured formations. Results show that the slope of this linear dispersivity function can be estimated using tracer concentration measurements in a monitoring well. The characterized dispersivity function has applications in modeling of field-scale transport processes in fractured formations. PMID:24660811

  20. Flow rate testing of valves used with the 500 gallon collapsible drum

    NASA Astrophysics Data System (ADS)

    Perdue, William D.

    1992-04-01

    This report covers the test and evaluation of four couplings/valves used with the 500-gallon collapsible drum: the existing poppet valve, a new redesigned poppet valve, a Carter refuel/defuel valve that works in conjunction with the single point refueling nozzle, and a Kamvalok dry-break coupling valve. The purpose of this testing was to determine maximum flow capability of each valve design and identify any new characteristics that may impact performance of the FARE system.

  1. NASA Ares I Launch Vehicle First Stage Roll Control System Cold Flow Development Test Program Overview

    NASA Technical Reports Server (NTRS)

    Butt, Adam; Popp, Christopher G.; Holt, Kimberly A.; Pitts, Hank M.

    2010-01-01

    The Ares I launch vehicle is the selected design, chosen to return humans to the moon, Mars, and beyond. It is configured in two inline stages: the First Stage is a Space Shuttle derived five-segment Solid Rocket Booster and the Upper Stage is powered by a Saturn V derived J-2X engine. During launch, roll control for the First Stage (FS) is handled by a dedicated Roll Control System (RoCS) located on the connecting Interstage. That system will provide the Ares I with the ability to counteract induced roll torque while any induced yaw or pitch moments are handled by vectoring of the booster nozzle. This paper provides an overview of NASA s Ares I FS RoCS cold flow development test program including detailed test objectives, types of tests run to meet those objectives, an overview of the results, and applicable lessons learned. The test article was built and tested at the NASA Marshall Space Flight Center in Huntsville, AL. The FS RoCS System Development Test Article (SDTA) is a full scale, flight representative water flow test article whose primary objective was to obtain fluid system performance data to evaluate integrated system level performance characteristics and verify analytical models. Development testing and model correlation was deemed necessary as there is little historical precedent for similar large flow, pulsing systems such as the FS RoCS. The cold flow development test program consisted of flight-similar tanks, pressure regulators, and thruster valves, as well as plumbing simulating flight geometries, combined with other facility grade components and structure. Orifices downstream of the thruster valves were used to simulate the pressure drop through the thrusters. Additional primary objectives of this test program were to: evaluate system surge pressure (waterhammer) characteristics due to thruster valve operation over a range of mission duty cycles at various feed system pressures, evaluate temperature transients and heat transfer in the

  2. The Sympathetic Release Test: A Test Used to Assess Thermoregulation and Autonomic Control of Blood Flow

    ERIC Educational Resources Information Center

    Tansey, E. A.; Roe, S. M.; Johnson, C. J.

    2014-01-01

    When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the…

  3. Flow-Visualization Techniques Used at High Speed by Configuration Aerodynamics Wind-Tunnel-Test Team

    NASA Technical Reports Server (NTRS)

    Lamar, John E. (Editor)

    2001-01-01

    This paper summarizes a variety of optically based flow-visualization techniques used for high-speed research by the Configuration Aerodynamics Wind-Tunnel Test Team of the High-Speed Research Program during its tenure. The work of other national experts is included for completeness. Details of each technique with applications and status in various national wind tunnels are given.

  4. Data qualification summary for 1985 L-Area AC Flow Tests

    SciTech Connect

    Edwards, T.B.; Eghbali, D.A.; Liebmann, M.L.; Shine, E.P.

    1992-03-01

    The 1985 L-Area AC Flow Tests were conducted to provide an extended data base for upgrading the reactor system models employed in predicting normal process water flows. This report summarizes the results of the recently completed, formal, technical review of the data from the 1985 L-Area AC Flow Tests as detailed in document SCS-CMAS-910045. The purpose of that review was to provide corroborating technical information as to the quality (fitness for use) of these experimental data. Reference [1] required three volumes to fully document the results of that Data Qualification process. This report has been prepared to provide the important conclusions from that process in a manageable and understandable format. Consult reference [1] if any additional information or detail is needed. This report provides highlights from that study: an overview of the tests and data, a description of the instrumentation used, an explanation of the data qualification methods employed to review the data, and the important conclusions reached from the study. Reference 1: Edwards, T.B., D.A. Eghbali, M.L. Liebmann, and E.P. Shine, [open quotes]Data Qualification for 1985 L-Area AC Flow Tests,[close quotes] SCS-CMAS-910045, December 31, 1991.

  5. Data qualification summary for 1985 L-Area AC Flow Tests

    SciTech Connect

    Edwards, T.B.; Eghbali, D.A.; Liebmann, M.L.; Shine, E.P.

    1992-03-01

    The 1985 L-Area AC Flow Tests were conducted to provide an extended data base for upgrading the reactor system models employed in predicting normal process water flows. This report summarizes the results of the recently completed, formal, technical review of the data from the 1985 L-Area AC Flow Tests as detailed in document SCS-CMAS-910045. The purpose of that review was to provide corroborating technical information as to the quality (fitness for use) of these experimental data. Reference [1] required three volumes to fully document the results of that Data Qualification process. This report has been prepared to provide the important conclusions from that process in a manageable and understandable format. Consult reference [1] if any additional information or detail is needed. This report provides highlights from that study: an overview of the tests and data, a description of the instrumentation used, an explanation of the data qualification methods employed to review the data, and the important conclusions reached from the study. Reference 1: Edwards, T.B., D.A. Eghbali, M.L. Liebmann, and E.P. Shine, {open_quotes}Data Qualification for 1985 L-Area AC Flow Tests,{close_quotes} SCS-CMAS-910045, December 31, 1991.

  6. 7 CFR 28.603 - Procedures for air flow tests of micronaire reading.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Procedures for air flow tests of micronaire reading... micronaire reading. In determining in terms of micronaire readings, the fiber fineness and maturity, in... cotton in terms of micronaire reading on the curvilinear scale adopted in September 1950 by...

  7. 7 CFR 28.603 - Procedures for air flow tests of micronaire reading.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Procedures for air flow tests of micronaire reading... micronaire reading. In determining in terms of micronaire readings, the fiber fineness and maturity, in... cotton in terms of micronaire reading on the curvilinear scale adopted in September 1950 by...

  8. 7 CFR 28.603 - Procedures for air flow tests of micronaire reading.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Procedures for air flow tests of micronaire reading... micronaire reading. In determining in terms of micronaire readings, the fiber fineness and maturity, in... cotton in terms of micronaire reading on the curvilinear scale adopted in September 1950 by...

  9. 7 CFR 28.603 - Procedures for air flow tests of micronaire reading.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Procedures for air flow tests of micronaire reading... micronaire reading. In determining in terms of micronaire readings, the fiber fineness and maturity, in... cotton in terms of micronaire reading on the curvilinear scale adopted in September 1950 by...

  10. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    NASA Technical Reports Server (NTRS)

    Xenofos, George; Forbes, John; Farrow, John; Williams, Robert; Tyler, Tom; Sargent, Scott; Moharos, Jozsef

    2003-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a fill-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrUmentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors. The test rig provided steady and unsteady pressure data necessary to validate the computational fluid dynamics (CFD) code. The rig also helped characterize the turbine blade loading conditions. Test and CFD analysis results are to be presented in another JANNAF paper.

  11. Single element injector cold flow testing for STME swirl coaxial injector element design

    NASA Technical Reports Server (NTRS)

    Hulka, J.; Schneider, J. A.

    1993-01-01

    An oxidizer-swirled coaxial element injector is being investigated for application in the Space Transportation Main Engine (STME). Single element cold flow experiments were conducted to provide characterization of the STME injector element for future analysis, design, and optimization. All tests were conducted to quiescent, ambient backpressure conditions. Spray angle, circumferential spray uniformity, dropsize, and dropsize distribution were measured in water-only and water/nitrogen flows. Rupe mixing efficiency was measured using water/sucrose solution flows with a large grid patternator for simple comparative evaluation of mixing. Factorial designs of experiment were used for statistical evaluation of injector geometrical design features and propellant flow conditions on mixing and atomization. Increasing the free swirl angle of the liquid oxidizer had the greatest influence on increasing the mixing efficiency. The addition of gas assistance had the most significant effect on reducing oxidizer droplet size parameters and increasing droplet size distribution. Increasing the oxidizer injection velocity had the greatest influence for reducing oxidizer droplet size parameters and increasing size distribution for non-gas assisted flows. Single element and multi-element subscale hot fire testing are recommended to verify optimized designs before committing to the STME design.

  12. A comparison of measured and predicted test flow in an expansion tube with air and oxygen test gases

    NASA Technical Reports Server (NTRS)

    Aaggard, K. V.; Goad, W. K.

    1975-01-01

    Simultaneous time-resolved measurements of temperature, density, pitot pressure, and wall pressure in both air and O2 test gases were obtained in the Langley pilot model expansion tube. These tests show nonequilibrium chemical and vibrational relaxation significantly affect the test-flow condition. The use of an electromagnetic device to preopen the secondary diaphragm before the arrival of the primary shock wave resulted in an improvement in the agreement between the measured pitot pressure and the value inferred from measured density and interface velocity. Boundary-layer splitter plates used to reduce the wall boundary layer show that this disagreement in the measured and inferred pitot pressures is not a result of boundary-layer effects.

  13. Orifice In-flow Efficiency Tests. Volume 1: Test Results. Volume 2: Application to Shuttle Venting During Entry

    NASA Technical Reports Server (NTRS)

    Haukohl, J.; Forkois, J. L.; Robertson, S. J.

    1972-01-01

    An investigation was made of the capability for computing internal pressures throughout flight for compartments located within space shuttle vehicles. A test program was conducted at a 6 x 6 foot supersonic wind tunnel to determine orifice efficiencies for the flow of air into a compartment from a flowing external stream. Measurements were made over a Mach number range of 0.7 to 1.9 for varying orifice geometry, vent orientation, vent plate thickness, flat plate boundary layer thickness, and pressure ratio across the vent plate. A computer program developed for outflow venting was modified for use in computing compartment pressures for inflow conditions. Results from both the outflow and inflow computer programs are included. A user's manual and program listing of the inflow venting program are also included.

  14. Flow-Log Analysis for Hydraulic Characterization of Selected Test Wells at the Indian Point Energy Center, Buchanan, New York

    USGS Publications Warehouse

    Williams, John H.

    2008-01-01

    Flow logs from 24 test wells were analyzed as part of the hydraulic characterization of the metamorphosed and fractured carbonate bedrock at the Indian Point Energy Center in Buchanan, New York. The flow logs were analyzed along with caliper, optical- and acoustic-televiewer, and fluid-resistivity and temperature logs to determine the character and distribution of fracture-flow zones and estimate their transmissivities and hydraulic heads. Many flow zones were associated with subhorizontal to shallow-dipping fractured zones, southeast-dipping bedding fractures, northwest-dipping conjugate fractures, or combinations of bedding and conjugate fractures. Flow-log analysis generally provided reasonable first-order estimates of flow-zone transmissivity and head differences compared with the results of conventional hydraulic-test analysis and measurements. Selected results of an aquifer test and a tracer test provided corroborating information in support of the flow-log analysis.

  15. Columbia University flow instability experimental program: Volume 7. Single tube tests, critical heat flux test program

    SciTech Connect

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    This report deals with critical heat flux (CHF) measurements in vertical down flow of water at low pressures in a round Inconel tube, 96 inches long and 0.62 inch inside diameter. A total of 28 CHF points were obtained. These data were found to correlate linearly with the single variable q, defined as the heat flux required to raise the enthalpy from the inlet value to the saturation value. These results were compared to the published results of Swedish investigators for vertical upflow of water at low pressures in round tubes of similar diameters and various lengths. The parameter q depends on the inlet enthalpy and is a nonlocal variable, thus this correlation is nonlocal unless the coefficients depend upon tube length in a particular prescribed manner. For the low pressure Swedish data, the coefficients are practically independent of length and hence the correlation is nonlocal. In the present investigation only one length was employed, so it is not possible to determine whether the correlation for these data is local or nonlocal, although there is reason to believe that it is local. The same correlation was applied to a large data base (thousands of CHF points) compiled from the published data of a number of groups and found to apply, with reasonable accuracy over a wide range of conditions, yielding sometimes local and sometimes nonlocal correlations. The basic philosophy of data analysis here was not to generate a single correlation which would reproduce all data, but to search for correlations which apply adequately over some range and which might have some mechanistic significance. The tentative conclusion is that at least two mechanisms appear operative, leading to two types of correlations, one local, the other nonlocal.

  16. Flight calibration tests of a nose-boom-mounted fixed hemispherical flow-direction sensor

    NASA Technical Reports Server (NTRS)

    Armistead, K. H.; Webb, L. D.

    1973-01-01

    Flight calibrations of a fixed hemispherical flow angle-of-attack and angle-of-sideslip sensor were made from Mach numbers of 0.5 to 1.8. Maneuvers were performed by an F-104 airplane at selected altitudes to compare the measurement of flow angle of attack from the fixed hemispherical sensor with that from a standard angle-of-attack vane. The hemispherical flow-direction sensor measured differential pressure at two angle-of-attack ports and two angle-of-sideslip ports in diametrically opposed positions. Stagnation pressure was measured at a center port. The results of these tests showed that the calibration curves for the hemispherical flow-direction sensor were linear for angles of attack up to 13 deg. The overall uncertainty in determining angle of attack from these curves was plus or minus 0.35 deg or less. A Mach number position error calibration curve was also obtained for the hemispherical flow-direction sensor. The hemispherical flow-direction sensor exhibited a much larger position error than a standard uncompensated pitot-static probe.

  17. Gas flow analysis during thermal vacuum test of a spacecraft. [self contamination of IMP spacecraft

    NASA Technical Reports Server (NTRS)

    Scialdone, J. J.

    1974-01-01

    The self-contamination of the IMP-H spacecraft, while it was undergoing thermal and solar vacuum tests, has been investigated in conjunction with the outgassing evaluation and detection of molecular flow anomalies occurring in the test chamber. The pressures indicated by two tubulated ionization gauges were used to calculate flow kinetics in the vacuum chamber. The fluxes of emitted molecules and chamber wall reflected molecules were monitored during the entire test. Representative equations and graphs are presented. Test results indicate that from 3 to 9 of every 100 emitted molecules returned to the spacecraft surface; that self-contamination by noncondensable gases was more severe than that by condensable gases; and that outgassing of the spacecraft was approximately 1.18 x 0.01 g/s after 10 hours and 1.18 x 0.001 after 90 hours of vacuum exposure. Testing deficiencies have been identified, and the type and location of instruments required to measure the outgassing, the degree of contamination, and return flow are discussed.

  18. Nature and extent of lava-flow aquifers beneath Pahute Mesa, Nevada Test Site

    SciTech Connect

    Prothro, L.B.; Drellack, S.L. Jr.

    1997-09-01

    Work is currently underway within the Underground Test Area subproject of the US Department of Energy/Nevada Operations Office Environmental Restoration Program to develop corrective action plans in support of the overall corrective action strategy for the Nevada Test Site as established in the Federal Facility Agreement and Consent Order (FFACO, 1996). A closure plan is currently being developed for Pahute Mesa, which has been identified in the FFACO as consisting of the Western and Central Pahute Mesa Corrective Action Units. Part of this effort requires that hydrogeologic data be compiled for inclusion in a regional model that will be used to predict a contaminant boundary for these Corrective Action Units. Hydrogeologic maps have been prepared for use in the model to define the nature and extent of aquifers and confining units that might influence the flow of contaminated groundwater from underground nuclear tests conducted at Pahute Mesa. Much of the groundwater flow beneath Pahute Mesa occurs within lava-flow aquifers. An understanding of the distribution and hydraulic character of these important hydrogeologic units is necessary to accurately model groundwater flow beneath Pahute Mesa. This report summarizes the results of a study by Bechtel Nevada geologists to better define the hydrogeology of lava-flow aquifers at Pahute Mesa. The purpose of this study was twofold: (1) aid in the development of the hydrostratigraphic framework for Pahute Mesa, and (2) provide information on the distribution and hydraulic character of lava-flow aquifers beneath Pahute Mesa for more accurate computer modeling of the Western and Central Pahute Mesa Corrective Action Units.

  19. Inlet Flow Test Calibration for a Small Axial Compressor Facility. Part 1: Design and Experimental Results

    NASA Technical Reports Server (NTRS)

    Miller, D. P.; Prahst, P. S.

    1994-01-01

    An axial compressor test rig has been designed for the operation of small turbomachines. The inlet region consisted of a long flowpath region with two series of support struts and a flapped inlet guide vane. A flow test was run to calibrate and determine the source and magnitudes of the loss mechanisms in the inlet for a highly loaded two-stage axial compressor test. Several flow conditions and IGV angle settings were established in which detailed surveys were completed. Boundary layer bleed was also provided along the casing of the inlet behind the support struts and ahead of the IGV. A detailed discussion of the flowpath design along with a summary of the experimental results are provided in Part 1.

  20. Brief Communication: A new testing field for debris flow warning systems and algorithms

    NASA Astrophysics Data System (ADS)

    Arattano, M.; Coviello, V.; Cavalli, M.; Comiti, F.; Macconi, P.; Marchi, L.; Theule, J.; Crema, S.

    2015-03-01

    Early warning systems (EWSs) are among the measures adopted for the mitigation of debris flow hazards. EWSs often employ algorithms that require careful and long testing to grant their effectiveness. A permanent installation has been so equipped in the Gadria basin (Eastern Italian Alps) for the systematic test of event-EWSs. The installation is conceived to produce didactic videos and host informative visits. The populace involvement and education is in fact an essential step in any hazard mitigation activity and it should envisaged in planning any research activity. The occurrence of a debris flow in the Gadria creek, in the summer of 2014, allowed a first test of the installation and the recording of an informative video on EWSs.

  1. The NASA Juncture Flow Experiment: Goals, Progress, and Preliminary Testing (Invited)

    NASA Technical Reports Server (NTRS)

    Rumsey, Christopher L.; Neuhart, Danny H.; Kegerise, Michael A.

    2016-01-01

    NASA has been working toward designing and conducting a juncture flow experiment on a wing-body aircraft configuration. The experiment is planned to provide validation-quality data for CFD that focuses on the onset and progression of a separation bubble near the wing-body juncture trailing edge region. This paper describes the goals and purpose of the experiment. Although currently considered unreliable, preliminary CFD analyses of several different configurations are shown. These configurations have been subsequently tested in a series of "risk-reduction" wind tunnel tests, in order to help down-select to a final configuration that will attain the desired flow behavior. The risk-reduction testing at the higher Reynolds number has not yet been completed (at the time of this writing), but some results from one of the low-Reynolds-number experiments are shown.

  2. Testing and benchmarking of a three-dimensional groundwater flow and solute transport model

    SciTech Connect

    Sims, P.N.; Andersen, P.F.; Faust, C.R.; Stephenson, D.E.

    1988-12-31

    A three-dimensional finite-difference model was developed to simulate groundwater flow and solute transport. The model is intended for application to a variety of groundwater resource and solute migration evaluations, including several complex sites at the Savannah River Plant (SRP). Because the model, FTWORK, is relatively new, there is a need to provide confidence in the model results. Methodologies that test models include comparisons with analytical solutions, comparisons with empirical data, and checking that conservation properties hold. Another level of testing is the comparison of one code against another. This paper describes the testing and benchmarking procedure used to verify the validate FTWORK.

  3. Field Test Results from a 10 kW Wind Turbine with Active Flow Control

    NASA Astrophysics Data System (ADS)

    Rice, Thomas; Bychkova, Veronika; Taylor, Keith; Clingman, Dan; Amitay, Michael

    2015-11-01

    Active flow control devices including synthetic jets and dynamic vortex generators were tested on a 10 kW wind turbine at RPI. Previous work has shown that load oscillations caused by dynamic stall could be modified through the use of active flow control by injecting momentum into the flow field near the leading edge of a dynamically pitching model. In this study, this work has been extended to its logical conclusion, field-testing active flow control on a real wind turbine. The blades in the current study have a 0.28m chord and 3.05m span, no twist or taper, and were retrofitted with six synthetic jets on one blade and ten dynamic vortex generators on a second blade. The third blade of this turbine was not modified, in order to serve as a control. Strain gauges were installed on each blade to measure blades' deflection. A simple closed loop control was demonstrated and preliminary results indicate reduced vibrational amplitude. Future testing will be conducted on a larger scale, 600kW machine at NREL, incorporating information collected during this study.

  4. Pneumatic testing in 45-degree-inclined boreholes in ash-flow tuff near Superior, Arizona

    USGS Publications Warehouse

    LeCain, G.D.

    1995-01-01

    Matrix permeability values determined by single-hole pneumatic testing in nonfractured ash-flow tuff ranged from 5.1 to 20.3 * 1046 m2 (meters squared), depending on the gas-injection rate and analysis method used. Results from the single-hole tests showed several significant correlations between permeability and injection rate and between permeability and test order. Fracture permeability values determined by cross-hole pneumatic testing in fractured ash-flow tuff ranged from 0.81 to 3.49 * 1044 m2, depending on injection rate and analysis method used. Results from the cross-hole tests monitor intervals showed no significant correlation between permeability and injection rate; however, results from the injection interval showed a significant correlation between injection rate and permeability. Porosity estimates from the 'cross-hole testing range from 0.8 to 2.0 percent. The maximum temperature change associated with the pneumatic testing was 1.2'(2 measured in the injection interval during cross-hole testing. The maximum temperature change in the guard and monitor intervals was O.Ip C. The maximum error introduced into the permeability values due to temperature fluctuations is approximately 4 percent. Data from temperature monitoring in the borehole indicated a positive correlation between the temperature decrease in the injection interval during recovery testing and the gas-injection rate. The thermocouple psychrometers indicated that water vapor was condensing in the boreholes during testing. The psychrometers in the guard and monitor intervals detected the drier injected gas as an increase in the dry bulb reading. The relative humidity in the test intervals was always higher than the upper measurement limit of the psychrometers. Although the installation of the packer system may have altered the water balance of the borehole, the gas-injection testing resulted in minimal or no changes in the borehole relative humidity.

  5. Computational investigation of the discharge coefficient of bellmouth flow meters in engine test facilities

    NASA Astrophysics Data System (ADS)

    Sebourn, Charles Lynn

    2002-11-01

    In this thesis computation of the discharge coefficient of bellmouth flow meters installed in engine test facilities is presented. The discharge coefficient is a critical parameter for accurately calculating flow rate in any flow meter which operates by means of creating a pressure differential. Engine airflow is a critical performance parameter and therefore, it is necessary for engine test facilities to accurately measure airflow. In this report the author investigates the use of computational fluid dynamics using finite difference methods to calculate the flow in bellmouth flow meters and hence the discharge coefficient at any measurement station desired. Experimental boundary layer and core flow data was used to verify the capability of the WIND code to calculate the discharge coefficient accurately. Good results were obtained for Reynolds numbers equal to or greater than about three million which is the primary range of interest. After verifying the WIND code performance, results were calculated for a range of Reynolds numbers and Mach numbers. Also the variation in discharge coefficient as a function of measurement location was examined. It is demonstrated that by picking the proper location for pressure measurement, sensitivity to measurement location can be minimized. Also of interest was the effect of bellmouth geometry. Calculations were performed to investigate the effect of duct to bellmouth diameter ratio and the eccentricity of the bellmouth contraction. In general the effects of the beta ratio were seen to be quite small. For the eccentricity, the variation in discharge coefficient was as high as several percent for axial locations less than half a diameter downstream from the throat. The second portion of the thesis examined the effect of a turbofan engine stationed just downstream of the bellmouth flow meter. The study approximated this effect by examining a single fan stage installed in the duct. This calculation was performed by making use of a

  6. Non-Flow-Through Fuel Cell System Test Results and Demonstration on the SCARAB Rover

    NASA Technical Reports Server (NTRS)

    Scheidegger, Brianne, T.; Burke, Kenneth A.; Jakupca, Ian J.

    2012-01-01

    This paper describes the results of the demonstration of a non-flow-through PEM fuel cell as part of a power system on the SCARAB rover. A 16-cell non-flow-through fuel cell stack from Infinity Fuel Cell and Hydrogen, Inc. was incorporated into a power system designed to act as a range extender by providing power to the rover s hotel loads. This work represents the first attempt at a ground demonstration of this new technology aboard a mobile test platform. Development and demonstration were supported by the Office of the Chief Technologist s Space Power Systems Project and the Advanced Exploration System Modular Power Systems Project.

  7. Evaluation of groundwater flow and transport at the Shoal underground nuclear test: An interim report

    SciTech Connect

    Pohll, G.; Chapman, J.; Hassan, A.; Papelis, C.; Andricevic, R.; Shirley, C.

    1998-07-01

    Since 1962, all United States nuclear tests have been conducted underground. A consequence of this testing has been the deposition of large amounts of radioactive materials in the subsurface, sometimes in direct contact with groundwater. The majority of this testing occurred on the Nevada Test Site, but a limited number of experiments were conducted in other locations. One of these is the subject of this report, the Project Shoal Area (PSA), located about 50 km southeast of Fallon, Nevada. The Shoal test consisted of a 12-kiloton-yield nuclear detonation which occurred on October 26, 1963. Project Shoal was part of studies to enhance seismic detection of underground nuclear tests, in particular, in active earthquake areas. Characterization of groundwater contamination at the Project Shoal Area is being conducted by the US Department of Energy (DOE) under the Federal Facility Agreement and Consent Order (FFACO) with the State of Nevada Department of Environmental Protection and the US Department of Defense (DOD). This order prescribes a Corrective Action Strategy (Appendix VI), which, as applied to underground nuclear tests, involves preparing a Corrective Action Investigation Plan (CAIP), Corrective Action Decision Document (CADD), Corrective Action Plan, and Closure Report. The scope of the CAIP is flow and transport modeling to establish contaminant boundaries that are protective of human health and the environment. This interim report describes the current status of the flow and transport modeling for the PSA.

  8. Space Launch System Base Heating Test: Environments and Base Flow Physics

    NASA Technical Reports Server (NTRS)

    Mehta, Manish; Knox, Kyle S.; Seaford, C. Mark; Dufrene, Aaron T.

    2016-01-01

    The NASA Space Launch System (SLS) vehicle is composed of four RS-25 liquid oxygen-hydrogen rocket engines in the core-stage and two 5-segment solid rocket boosters and as a result six hot supersonic plumes interact within the aft section of the vehicle during flight. Due to the complex nature of rocket plume-induced flows within the launch vehicle base during ascent and a new vehicle configuration, sub-scale wind tunnel testing is required to reduce SLS base convective environment uncertainty and design risk levels. This hot-fire test program was conducted at the CUBRC Large Energy National Shock (LENS) II short-duration test facility to simulate flight from altitudes of 50 kft to 210 kft. The test program is a challenging and innovative effort that has not been attempted in 40+ years for a NASA vehicle. This paper discusses the various trends of base convective heat flux and pressure as a function of altitude at various locations within the core-stage and booster base regions of the two-percent SLS wind tunnel model. In-depth understanding of the base flow physics is presented using the test data, infrared high-speed imaging and theory. The normalized test design environments are compared to various NASA semi-empirical numerical models to determine exceedance and conservatism of the flight scaled test-derived base design environments. Brief discussion of thermal impact to the launch vehicle base components is also presented.

  9. Regional groundwater flow and tritium transport modeling and risk assessment of the underground test area, Nevada Test Site, Nevada

    SciTech Connect

    1997-10-01

    The groundwater flow system of the Nevada Test Site and surrounding region was evaluated to estimate the highest potential current and near-term risk to the public and the environment from groundwater contamination downgradient of the underground nuclear testing areas. The highest, or greatest, potential risk is estimated by assuming that several unusually rapid transport pathways as well as public and environmental exposures all occur simultaneously. These conservative assumptions may cause risks to be significantly overestimated. However, such a deliberate, conservative approach ensures that public health and environmental risks are not underestimated and allows prioritization of future work to minimize potential risks. Historical underground nuclear testing activities, particularly detonations near or below the water table, have contaminated groundwater near testing locations with radioactive and nonradioactive constituents. Tritium was selected as the contaminant of primary concern for this phase of the project because it is abundant, highly mobile, and represents the most significant contributor to the potential radiation dose to humans for the short term. It was also assumed that the predicted risk to human health and the environment from tritium exposure would reasonably represent the risk from other, less mobile radionuclides within the same time frame. Other contaminants will be investigated at a later date. Existing and newly collected hydrogeologic data were compiled for a large area of southern Nevada and California, encompassing the Nevada Test Site regional groundwater flow system. These data were used to develop numerical groundwater flow and tritium transport models for use in the prediction of tritium concentrations at hypothetical human and ecological receptor locations for a 200-year time frame. A numerical, steady-state regional groundwater flow model was developed to serve as the basis for the prediction of the movement of tritium from the

  10. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. 84.155 Section... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type... shall not exceed 25 mm. (1 inch) of water-column height when the air flow into the...

  11. A system for conducting flow-through toxicity tests with larval fish

    SciTech Connect

    Diamond, S.A.; Oris, J.T.; Guttman, S.I.

    1995-08-01

    Assessment of toxicological effects in aquatic systems commonly include larval fish 96-h LC50 determinations. The LC50 tests are conducted using static renewal as well as flow-through methods. However, in the case of chemicals with high vapor pressures or fugacity, static renewal methods may produce inconsistent results arising from the pulsed nature of exposure. In addition, in exposures involving these types of compounds, the fluctuation in concentration that can occur between renewals is unlike most exposure scenarios in nature. For these reasons, flow-through systems are often preferable. The authors report here on an inexpensive, easily constructed, flow-through system for toxicant exposure of small organisms. Data are presented to illustrate the capacity of the system to maintain uniform toxicant concentrations relative to static renewal methods.

  12. UNSATURATED FLOW IN A CENTRIFUGAL FIELD: MEASUREMENT OF HYDRAULIC CONDUCTIVITY AND TESTING OF DARCY'S LAW.

    USGS Publications Warehouse

    Nimmo, J.R.; Rubin, J.; Hammermeister, D.P.

    1987-01-01

    A method has been developed to establish steady flow of water in unsaturated soil sample spinning in a centrifuge. Theoretical analysis predicts moisture conditions in the sample that depend strongly on soil type and certain operating parameter. For Oakley sand, measurements of flux, water content, and matric potential during and after centrifugation verify that steady state flow can be achieved. Experiments have confirmed the theoretical prediction of a nearly uniform moisture distribution for this medium and have demonstrated that the flow can be effectively one-dimensional. The method was used for steady state measurements of hydraulic conductivity K for relatively dry soil, giving values at low as 7. 6 multiplied by 10** minus **1**1 m/s with data obtained in a few hours. Darcy's law was tested by measuring K for different centrifugal driving forces but with the same water content.

  13. Graphical method for determining the coefficient of consolidation cv from a flow-pump permeability test

    USGS Publications Warehouse

    Morin, Roger H.; Olsen, Harold W.; Nelson, Karl R.; Gill, James D.

    1989-01-01

    A graphical method has been developed for determining the coefficient of consolidation from the transient phases of a flow-pump permeability test. The flow pump can be used to infuse fluid into or withdraw fluid from a laboratory sediment specimen at a constant volumetric rate in order to obtain data that can be used to calculate permeability using Darcy's law. Representative type-curve solutions to the associated forced-flow and pressure-decay models are derived. These curves provide the basis for graphically evaluating the permeability k, the coefficient of consolidation cv, and the coefficient of volume change mv. The curve-matching technique is easy and rapid. Values of k, cv and mv for a laterally confined kaolinite specimen were determined by this graphical method and appear to be in reasonably good agreement with numerically derived estimates (within 20%). Discrepancies between the two sets of results seem to be largely a function of data quality.

  14. Cold Flow Testing for Liquid Propellant Rocket Injector Scaling and Throttling

    NASA Technical Reports Server (NTRS)

    Kenny, Jeremy R.; Moser, Marlow D.; Hulka, James; Jones, Gregg

    2006-01-01

    Scaling and throttling of combustion devices are important capabilities to demonstrate in development of liquid rocket engines for NASA's Space Exploration Mission. Scaling provides the ability to design new injectors and injection elements with predictable performance on the basis of test experience with existing injectors and elements, and could be a key aspect of future development programs. Throttling is the reduction of thrust with fixed designs and is a critical requirement in lunar and other planetary landing missions. A task in the Constellation University Institutes Program (CUIP) has been designed to evaluate spray characteristics when liquid propellant rocket engine injectors are scaled and throttled. The specific objectives of the present study are to characterize injection and primary atomization using cold flow simulations of the reacting sprays. These simulations can provide relevant information because the injection and primary atomization are believed to be the spray processes least affected by the propellant reaction. Cold flow studies also provide acceptable test conditions for a university environment. Three geometric scales - 1/4- scale, 1/2-scale, and full-scale - of two different injector element types - swirl coaxial and shear coaxial - will be designed, fabricated, and tested. A literature review is currently being conducted to revisit and compile the previous scaling documentation. Because it is simple to perform, throttling will also be examined in the present work by measuring primary atomization characteristics as the mass flow rate and pressure drop of the six injector element concepts are reduced, with corresponding changes in chamber backpressure. Simulants will include water and gaseous nitrogen, and an optically accessible chamber will be used for visual and laser-based diagnostics. The chamber will include curtain flow capability to repress recirculation, and additional gas injection to provide independent control of the

  15. Validation Analysis of the Groundwater Flow and Transport Model of the Central Nevada Test Area

    SciTech Connect

    A. Hassan; J. Chapman; H. Bekhit; B. Lyles; K. Pohlmann

    2006-09-30

    The Central Nevada Test Area (CNTA) is a U.S. Department of Energy (DOE) site undergoing environmental restoration. The CNTA is located about 95 km northeast of Tonopah, Nevada, and 175 km southwest of Ely, Nevada (Figure 1.1). It was the site of the Faultless underground nuclear test conducted by the U.S. Atomic Energy Commission (DOE's predecessor agency) in January 1968. The purposes of this test were to gauge the seismic effects of a relatively large, high-yield detonation completed in Hot Creek Valley (outside the Nevada Test Site [NTS]) and to determine the suitability of the site for future large detonations. The yield of the Faultless underground nuclear test was between 200 kilotons and 1 megaton (DOE, 2000). A three-dimensional flow and transport model was created for the CNTA site (Pohlmann et al., 1999) and determined acceptable by DOE and the Nevada Division of Environmental Protection (NDEP) for predicting contaminant boundaries for the site.

  16. Laboratory Tests of Multiplex Detection of PCR Amplicons Using the Luminex 100 Flow Analyzer

    SciTech Connect

    Venkateswaran, K.S.; Nasarabadi, S.; Langlois, R.G.

    2000-05-05

    Lawrence Livermore National Laboratory (LLNL) demonstrated the power of flow cytometry in detecting the biological agents simulants at JFT III. LLNL pioneered in the development of advanced nucleic acid analyzer (ANM) for portable real time identification. Recent advances in flow cytometry provide a means for multiplexed nucleic acid detection and immunoassay of pathogenic microorganisms. We are presently developing multiplexed immunoassays for the simultaneous detection of different simulants. Our goal is to build an integrated instrument for both nucleic acid analysis and immuno detection. In this study we evaluated the Luminex LX 100 for concurrent identification of more than one PCR amplified product. ANAA has real-time Taqman fluorescent detection capability for rapid identification of field samples. However, its multiplexing ability is limited by the combination of available fluorescent labels. Hence integration of ANAA with flow cytometry can give the rapidity of ANAA amplification and the multiplex capability of flow cytometry. Multiplexed flow cytometric analysis is made possible using a set of fluorescent latex microsphere that are individually identified by their red and infrared fluorescence. A green fluorochrome is used as the assay signal. Methods were developed for the identification of specific nucleic acid sequences from Bacillus globigii (Bg), Bacillus thuringensis (Bt) and Erwinia herbicola (Eh). Detection sensitivity using different reporter fluorochromes was tested with the LX 100, and also different assay formats were evaluated for their suitability for rapid testing. A blind laboratory trial was carried out December 22-27, 1999 to evaluate bead assays for multiplex identification of Bg and Bt PCR products. This report summarizes the assay development, fluorochrome comparisons, and the results of the blind trial conducted at LLNL for the laboratory evaluation of the LX 100 flow analyzer.

  17. Multiple well-shutdown tests and site-scale flow simulation in fractured rocks.

    PubMed

    Tiedeman, Claire R; Lacombe, Pierre J; Goode, Daniel J

    2010-01-01

    A new method was developed for conducting aquifer tests in fractured-rock flow systems that have a pump-and-treat (P&T) operation for containing and removing groundwater contaminants. The method involves temporary shutdown of individual pumps in wells of the P&T system. Conducting aquifer tests in this manner has several advantages, including (1) no additional contaminated water is withdrawn, and (2) hydraulic containment of contaminants remains largely intact because pumping continues at most wells. The well-shutdown test method was applied at the former Naval Air Warfare Center (NAWC), West Trenton, New Jersey, where a P&T operation is designed to contain and remove trichloroethene and its daughter products in the dipping fractured sedimentary rocks underlying the site. The detailed site-scale subsurface geologic stratigraphy, a three-dimensional MODFLOW model, and inverse methods in UCODE_2005 were used to analyze the shutdown tests. In the model, a deterministic method was used for representing the highly heterogeneous hydraulic conductivity distribution and simulations were conducted using an equivalent porous media method. This approach was very successful for simulating the shutdown tests, contrary to a common perception that flow in fractured rocks must be simulated using a stochastic or discrete fracture representation of heterogeneity. Use of inverse methods to simultaneously calibrate the model to the multiple shutdown tests was integral to the effectiveness of the approach.

  18. Heat extracted from the long term flow test in the Fenton Hill HDR reservoir

    SciTech Connect

    Kruger, Paul; Robinson, Bruce

    1994-01-20

    A long-term flow test was carried out in the Fenton Hill HDR Phase-2 reservoir for 14 months during 1992-1993 to examine the potential for supplying thermal energy at a sustained rate as a commercial demonstration of HDR technology. The test was accomplished in several segments with changes in mean flowrate due to pumping conditions. Re-test estimates of the extractable heat content above a minimum useful temperature were based on physical evidence of the size of the Fenton Hill reservoir. A numerical model was used to estimate the extent of heat extracted during the individual flow segments from the database of measured production data during the test. For a reservoir volume of 6.5x10{sup 6}m{sup 3}, the total heat content above a minimum temperature of 150{degree} C was 1.5x10{sup 15}J. For the total test period at the three sustained mean flowrates, the integrated heat extracted was 0.088x10{sup 15}J, with no discernable temperature decline of the produced fluid. The fraction of energy extracted above the abandonment temperature was 5.9%. On the basis of a constant thermal energy extraction rate, the lifetime of the reservoir (without reservoir growth) to the abandonment temperature would be 13.3 years, in good agreement with the pre-test estimate of 15.0 years for the given reservoir volume.

  19. Test technique development in interference free testing, flow visualization, and remote control model technology at Langley's Unitary Plan wind tunnel

    NASA Technical Reports Server (NTRS)

    Corlett, W. A.

    1979-01-01

    A metric half-span model is considered as a means of mechanical support for a wind-tunnel model which allows measurement of aerodynamic forces and moments without support interference or model distortion. This technique can be applied to interference-free propulsion models. The vapor screen method of flow visualization at supersonic Mach numbers is discussed. The use of smoke instead of water vapor as a medium to produce the screen is outlined. Vapor screen data are being used in the development of analytical vortex tracking programs. Test results for a remote control model system are evaluated. Detailed control effectiveness and cross-coupling data were obtained with a single run. For the afterbody tail configuration, tested control boundaries at several roll orientations were established utilizing the facility's on-line capability to 'fly' the model in the wind tunnel.

  20. Design and Testing of a Shell-Flow Hollow-Fiber Venting Gas Trap

    NASA Technical Reports Server (NTRS)

    Bue, Grant C.; Cross, Cindy; Hansen, Scott; Vogel, Matthew; Dillon, Paul

    2013-01-01

    A Venting Gas Trap (VGT) was designed, built, and tested at NASA Johnson Space Center to eliminate dissolved and free gas from the circulating coolant loop of the Orion Environmental Control Life Support System. The VGT was downselected from two different designs. The VGT has robust operation, and easily met all the Orion requirements, especially size and weight. The VGT has a novel design with the gas trap made of a five-layer spiral wrap of porous hydrophobic hollow fibers that form a cylindrically shaped curtain terminated by a dome-shaped distal plug. Circulating coolant flows into the center of the cylindrical curtain and flows between the hollow fibers, around the distal plug, and exits the VGT outlet. Free gas is forced by the coolant flow to the distal plug and brought into contact with hollow fibers. The proximal ends of the hollow fibers terminate in a venting chamber that allows for rapid venting of the free gas inclusion, but passively limits the external venting from the venting chamber through two small holes in the event of a long-duration decompression of the cabin. The VGT performance specifications were verified in a wide range of flow rates, bubble sizes, and inclusion volumes. Long-duration and integrated Orion human tests of the VGT are also planned for the coming year.

  1. Design, testing and two-dimensional flow modeling of a multiple-disk fan

    SciTech Connect

    Engin, Tahsin; Oezdemir, Mustafa; Cesmeci, Sevki

    2009-11-15

    A multiple-disk Tesla type fan has been designed, tested and analyzed two-dimensionally using the conservation of angular momentum principle. Experimental results showed that such multiple-disk fans exhibited exceptionally low performance characteristics, which could be attributed to the low viscosity, tangential nature of the flow, and large mechanical energy losses at both suction and discharge sections that are comparable to the total input power. By means of theoretical analysis, local and overall shearing stresses on the disk surfaces have been determined based on tangential and radial velocity distributions of the air flow of different volume flow rates at prescribed disk spaces and rotational speeds. Then the total power transmitted by rotating disks to air flow, and the power acquired by the air flow in the gap due to transfer of angular momentum have been obtained by numerically integrating shearing stresses over the disk surfaces. Using the measured shaft and hydraulic powers, these quantities were utilized to evaluate mechanical energy losses associated with the suction and discharge sections of the fan. (author)

  2. Velocimetry modalities for secondary flows in a curved artery test section

    NASA Astrophysics Data System (ADS)

    Bulusu, Kartik V.; Elkins, Christopher J.; Banko, Andrew J.; Plesniak, Michael W.; Eaton, John K.

    2014-11-01

    Secondary flow structures arise due to curvature-related centrifugal forces and pressure imbalances. These flow structures influence wall shear stress and alter blood particle residence times. Magnetic resonance velocimetry (MRV) and particle image velocimetry (PIV) techniques were implemented independently, under the same physiological inflow conditions (Womersley number = 4.2). A 180-degree curved artery test section with curvature ratio (1/7) was used as an idealized geometry for curved arteries. Newtonian blood analog fluids were used for both MRV and PIV experiments. The MRV-technique offers the advantage of three-dimensional velocity field acquisition without requiring optical access or flow markers. Phase-averaged, two-dimensional, PIV-data at certain cross-sectional planes and inflow phases were compared to phase-averaged MRV-data to facilitate the characterization of large-scale, Dean-type vortices. Coherent structures detection methods that included a novel wavelet decomposition-based approach to characterize these flow structures was applied to both PIV- and MRV-data. The overarching goal of this study is the detection of motific, three-dimensional shapes of secondary flow structures using MRV techniques with guidance obtained from high fidelity, 2D-PIV measurements. This material is based in part upon work supported by the National Science Foundation under Grant Number CBET-0828903, and GW Center for Biomimetics and Bioinspired Engineering (COBRE).

  3. Improvement of Subsonic Basic Research Tunnel Flow Quality as Applied to Wall Mounted Testing

    NASA Technical Reports Server (NTRS)

    Howerton, Brian M.

    1995-01-01

    A survey to determine the characteristics of a boundary layer that forms on the wall of the Subsonic Basic Research Tunnel has been performed. Early results showed significant differences in the velocity profiles as measured spanwise across the wall. An investigation of the flow in the upstream contraction revealed the presence of a separation bubble at the beginning of the contraction which caused much of the observed unsteadiness. Vortex generators were successfully applied to the contraction inlet to alleviate the separation. A final survey of the wall boundary layer revealed variations in the displacement and momentum thicknesses to be less than +/- 5% for all but the most upper portion of the wall. The flow quality was deemed adequate to continue the planned follow-on tests to help develop the semi-span test technique.

  4. Brief Communication: A new testing field for debris flow warning systems

    NASA Astrophysics Data System (ADS)

    Arattano, M.; Coviello, V.; Cavalli, M.; Comiti, F.; Macconi, P.; Theule, J.; Crema, S.

    2015-07-01

    A permanent field installation for the systematic test of debris flow warning systems and algorithms has been equipped on the eastern Italian Alps. The installation was also designed to produce didactic videos and it may host informative visits. The populace education is essential and should be envisaged in planning any research on hazard mitigation interventions: this new installation responds to this requirement and offers an example of integration between technical and informative needs. The occurrence of a debris flow in 2014 allowed the first tests of a new warning system under development and to record an informative video on its performances. This paper will provide a description of the installation and an account of the first technical and informative results obtained.

  5. Oscillating-Flow Regenerator Test Rig: Hardware and Theory With Derived Correlations for Screens and Felts

    NASA Technical Reports Server (NTRS)

    Gedeon, D.; Wood, J. G.

    1996-01-01

    A number of wire mesh and metal felt test samples, with a range of porosities, yield generic correlations for friction factor, Nusselt number, enhanced axial conduction ratio, and overall heat flux ratio. This information is directed primarily toward stirling cycle regenerator modelers, but will be of use to anyone seeking to better model fluid flow through these porous materials. Behind these results lies an oscillating-flow test rig, which measures pumping dissipation and thermal energy transport in sample matrices, and several stages of data-reduction software, which correlate instantaneous values for the above dimensionless groups. Within the software, theoretical model reduces instantaneous quantifies from cycle-averaged measurables using standard parameter estimation techniques.

  6. Development and testing of highway storm-sewer flow measurement and recording system

    USGS Publications Warehouse

    Kilpatrick, F.A.; Kaehrle, W.R.; Hardee, Jack; Cordes, E.H.; Landers, M.N.

    1985-01-01

    A comprehensive study and development of measuring instruments and techniques for measuring all components of flow in a storm-sewer drainage system was undertaken by the U.S. Geological Survey under the sponsorship of the Federal Highway Administration. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, electromagnetic velocity meters as well as the development and calibration of pneumatic-bubbler pressure transducer head measuring systems. Tracer-dilution and acoustic flow meter measurements were used in field verification tests. A single micrologger was used to record data from all the above instruments as well as from a tipping-bucket rain gage and also to activate on command the electromagnetic velocity meter and tracer-dilution systems. (Author 's abstract)

  7. THEORETICAL ANALYSIS OF THE TRANSIENT PRESSURE RESPONSE FROM A CONSTANT FLOW RATE HYDRAULIC CONDUCTIVITY TEST.

    USGS Publications Warehouse

    Morin, Roger H.; Olsen, Harold W.

    1987-01-01

    Incorporating a flow pump into a conventional triaxial laboratory system allows fluid to be supplied to or withdrawn from the base of a sediment sample at small and constant rates. An initial transient record of hydraulic head versus time is observed which eventually stabilizes to a constant steady state gradient across the sample; values of hydraulic conductivity can subsequently be determined from Darcy's law. In this paper, analytical methods are presented for determining values of specific storage and hydraulic conductivity from the initial transient phase of such a constant flow rate test. These methods are based on a diffusion equation involving pore pressure and are analogous to those used to describe the soil consolidation process and also to interpret aquifer properties from pumping tests.

  8. An analytical verification test for numerically simulated convective flow above a thermally heterogeneous surface

    NASA Astrophysics Data System (ADS)

    Shapiro, A.; Fedorovich, E.; Gibbs, J. A.

    2015-06-01

    An analytical solution of the Boussinesq equations for the motion of a viscous stably stratified fluid driven by a surface thermal forcing with large horizontal gradients (step changes) is obtained. This analytical solution is one of the few available for wall-bounded buoyancy-driven flows. The solution can be used to verify that computer codes for Boussinesq fluid system simulations are free of errors in formulation of wall boundary conditions and to evaluate the relative performances of competing numerical algorithms. Because the solution pertains to flows driven by a surface thermal forcing, one of its main applications may be for testing the no-slip, impermeable wall boundary conditions for the pressure Poisson equation. Examples of such tests are presented.

  9. Aft-End Flow of a Large-Scale Lifting Body During Free-Flight Tests

    NASA Technical Reports Server (NTRS)

    Banks, Daniel W.; Fisher, David F.

    2006-01-01

    Free-flight tests of a large-scale lifting-body configuration, the X-38 aircraft, were conducted using tufts to characterize the flow on the aft end, specifically in the inboard region of the vertical fins. Pressure data was collected on the fins and base. Flow direction and movement were correlated with surface pressure and flight condition. The X-38 was conceived to be a rescue vehicle for the International Space Station. The vehicle shape was derived from the U.S. Air Force X-24 lifting body. Free-flight tests of the X-38 configuration were conducted at the NASA Dryden Flight Research Center at Edwards Air Force Base, California from 1997 to 2001.

  10. Performance evaluation of pyrochlore ceramic waste forms by single pass flow through testing

    NASA Astrophysics Data System (ADS)

    Zhao, P.; Bourcier, W. L.; Esser, B. K.; Shaw, H. F.

    2000-07-01

    Titanate-based ceramic waste forms for the disposal of nuclear wastes have been the subjects of numerous studies over the past decades. In order to assess the performance of this ceramic in a potential Yucca Mountain high-level waste (HLW) repository, it is necessary to understand the kinetics and mechanisms of corrosion of the ceramic under repository conditions. To this end, we are conducting single pass flow-through (SPFT) dissolution tests on ceramics relevant to Pu disposition.

  11. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance test; Type C supplied-air... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. The resistance to air flowing from the...

  12. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance test; Type C supplied-air... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. The resistance to air flowing from the...

  13. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance test; Type C supplied-air... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. The resistance to air flowing from the...

  14. 42 CFR 84.155 - Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance test; Type C supplied-air... Respirators § 84.155 Airflow resistance test; Type C supplied-air respirator, continuous flow class and Type CE supplied-air respirator; minimum requirements. The resistance to air flowing from the...

  15. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the flow rate cut-off test, download the archived data from the test sampler and verify that the... recording at intervals not to exceed 5 minutes. (4) Flow measurement adaptor (40 CFR part 50, appendix L.... (7) Teflon sample filter, as specified in section 6 of 40 CFR part 50, appendix L (if required)....

  16. Flow testing of the Newberry 2 research drillhole, Newberry volcano, Oregon

    USGS Publications Warehouse

    Ingebritsen, S.E.; Carothers, W.W.; Mariner, R.H.; Gudmundsson, J.S.; Sammel, E.A.

    1986-01-01

    A 20 hour flow test of the Newberry 2 research drillhole at Newberry Volcano produced about 33,000 kilograms of fluid. The flow rate declined from about 0.8 kilograms per sec to less than 0.3 kilograms per sec during the course of the test. The mass ratio of liquid water to vapor was about 3:2 at the separator and stayed fairly constant throughout the test. The vapor phase was about half steam and half CO2 by weight. The average enthalpy of the steam/water mixture at the separator was about 1 ,200 kilojoules per kilogram. Because of the low flow rate and the large temperature gradient into the surrounding rocks, heat loss from the wellbore was high; a simple conductive model gives overall losses of about 1,200 kilojoules per kilogram of H2O produced. The actual heat loss may have been even higher due to convective effects, and it is likely that the fluid entering the bottom of the wellbore was largely or entirely steam and CO2. (Author 's abstract)

  17. Serology with ML Flow test in health professionals from three different states of Brazil*

    PubMed Central

    Calado, Karla Lucena Sampaio; Magnanini, Mônica Maria Ferreira; de Moura, Rodrigo Scaliante; Gallo, Maria Eugenia Noviski; Bührer-Sékula, Samira; de Oliveira, Maria Leide Wand-Del-Rey

    2013-01-01

    BACKGROUND In highly endemic countries, transmission and sub-clinical infection of leprosy are likely and the disease manifests itself in individuals without any known close contact with a leprosy patient. Health workers are social contacts belonging to the same network (the Health System) and some of them share the same social environment (nursing assistants) as patients with known patients and / or carriers. OBJECTIVE To identify ML Flow seropositivity among health professionals. METHODS We conducted a cross-sectional study using a serological survey with the ML Flow test in 450 health professionals (doctors, nurses and nursing assistants), in order to detect seropositivity in areas of high and low endemicity in municipalities from three Brazilian states (RJ, MS and RS). RESULTS The results showed general 16% seropositivity, higher in low endemic areas, regardless of whether there was direct care for leprosy patients. Paradoxically, a statistical association was observed between the area studied and seropositivity, as the place with the lowest endemicity (CA) had the highest seropositivity rate (p = 0.033). CONCLUSION The authors suggest these results are associated with a presence of an unspecified link to bovine serum albumin (BSA), carrier of PGL-1 in the ML Flow test, and recommend expanded seroepidemiological research utilizing tests with human and bovine albumin. PMID:24474100

  18. Flowing along the edge: Spinning up black holes in AdS spacetimes with test particles

    NASA Astrophysics Data System (ADS)

    Rocha, Jorge V.; Santarelli, Raphael

    2014-03-01

    We investigate the consequences of throwing point particles into odd-dimensional Myers-Perry black holes in asymptotically anti-de Sitter (AdS) backgrounds. We restrict our attention to the case in which the angular momenta of the background geometry are all equal. This process allows us to test the generalization of the weak cosmic censorship conjecture to asymptotically AdS spacetimes in higher dimensions. We find no evidence for overspinning in D =5,7,9 and 11 dimensions. Instead, test particles carrying the maximum possible angular momentum that still fall into an extremal rotating black hole generate a flow along the curve of extremal solutions.

  19. An analytical verification test for numerically simulated convective flow above a thermally heterogeneous surface

    NASA Astrophysics Data System (ADS)

    Shapiro, A.; Fedorovich, E.; Gibbs, J. A.

    2015-03-01

    An analytical solution of the Boussinesq equations for the motion of a viscous stably stratified fluid driven by a surface thermal forcing with large horizontal gradients (step changes) is obtained. The solution can be used to verify that computer codes for Boussinesq fluid system simulations are free of errors in formulation of wall boundary conditions, and to evaluate the relative performances of competing numerical algorithms. Because the solution pertains to flows driven by a surface thermal forcing, one of its main applications may be for testing the no-slip, impermeable wall boundary conditions for the pressure Poisson equation. Examples of such tests are presented.

  20. Distribution and biomarkers of carbon-14-labeled fullerene C60 ([(14) C(U)]C60 ) in female rats and mice for up to 30 days after intravenous exposure.

    PubMed

    Sumner, Susan C J; Snyder, Rodney W; Wingard, Christopher; Mortensen, Ninell P; Holland, Nathan A; Shannahan, Jonathan H; Dhungana, Suraj; Pathmasiri, Wimal; Han, Li; Lewin, Anita H; Fennell, Timothy R

    2015-12-01

    A comprehensive distribution study was conducted in female rats and mice exposed to a suspension of uniformly carbon-14-labeled C60 ([(14) C(U)]C60 ). Rodents were administered [(14) C(U)]C60 (~0.9 mg kg(-1) body weight) or 5% polyvinylpyrrolidone-saline vehicle alone via a single tail vein injection. Tissues were collected at 1 h and 1, 7, 14 and 30 days after administration. A separate group of rodents received five daily injections of suspensions of either [(14) C(U)]C60 or vehicle with tissue collection 14 days post exposure. Radioactivity was detected in over 20 tissues at all time points. The highest concentration of radioactivity in rodents at each time point was in liver, lungs and spleen. Elimination of [(14) C(U)]C60 was < 2% in urine and feces at any 24 h time points. [(14) C(U)]C60 and [(14) C(U)]C60 -retinol were detected in liver of rats and together accounted for ~99% and ~56% of the total recovered at 1 and 30 days postexposure, respectively. The blood radioactivity at 1 h after [(14) C(U)]C60 exposure was fourfold higher in rats than in mice; blood radioactivity was still in circulation at 30 days post [(14) C(U)]C60 exposure in both species (<1%). Levels of oxidative stress markers increased by 5 days after exposure and remained elevated, while levels of inflammation markers initially increased and then returned to control values. The level of cardiovascular marker von Willebrand factor, increased in rats, but remained at control levels in mice. This study demonstrates that [(14) C(U)]C60 is retained in female rodents with little elimination by 30 days after i.v. exposure, and leads to systemic oxidative stress.