Science.gov

Sample records for 384-well microtiter plate

  1. Reproducibility of Uniform Spheroid Formation in 384-Well Plates: The Effect of Medium Evaporation.

    PubMed

    Das, Viswanath; Fürst, Tomáš; Gurská, Soňa; Džubák, Petr; Hajdúch, Marián

    2016-10-01

    Spheroid cultures of cancer cells reproduce the spatial dimension-induced in vivo tumor traits more effectively than the conventional two-dimensional cell cultures. With growing interest in spheroids for high-throughput screening (HTS) assays, there is an increasing demand for cost-effective miniaturization of reproducible spheroids in microtiter plates (MPs). However, well-to-well variability in spheroid size, shape, and growth is a frequently encountered problem with almost every culture method that has prevented the transfer of spheroids to the HTS platform. This variability partly arises due to increased susceptibility of MPs to edge effects and evaporation-induced changes in the growth of spheroids. In this study, we examined the effect of evaporation on the reproducibility of spheroids of tumor and nontumor cell lines in 384-well plates, and show that culture conditions that prevent evaporation-induced medium loss result in the formation of uniform spheroids across the plate. Additionally, we also present a few technical improvements to increase the scalability of the liquid-overlay spheroid culturing technique in MPs, together with a simple software routine for the quantification of spheroid size. We believe that these cost-effective improvements will aid in further improvement of spheroid cultures for HTS drug discovery.

  2. A new platform for electrochemical analysis of a microtiter plate

    NASA Astrophysics Data System (ADS)

    Allen, Brian P.; Gilbert, Richard J.; Zhou, Xiao-Feng

    2004-12-01

    A disposable device is described for use in High Content Screening within the drug research process; it interfaces with a standard 384 well microtiter plate providing simultaneous full kinetic reaction data for a complete row of 24 wells. The device can be used in secondary screening for lead optimisation, for ADME (Absorption Distribution Metabolism and Excretion) assessment and toxicological assessment of candidate compounds. The device is a microfluidic unit and incorporates the necessary substrate and reaction chemicals. The microfluidic circuitry includes mixing paths, a reaction chamber, a single use valve and a waste reservoir as well as electrical measurement contacts. Movement of the fluids is provided by a single vacuum line which is distributed to all 24 separate cells. The device described incorporates a self-validation technique which provides a built in test facility.

  3. Microtiter plate-based antibody microarrays for bacteria and toxins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...

  4. Mixing at the microscale: Power input in shaken microtiter plates.

    PubMed

    Dürauer, Astrid; Hobiger, Stefanie; Walther, Cornelia; Jungbauer, Alois

    2016-12-01

    Power input and local energy dissipation are crucial parameters for the engineering characterization of mixing and fluid dynamics at the microscale. Since hydrodynamic stress is solely dependent on the maximum power input, we adapted the clay/polymer method to obtain flock destruction kinetics in six-, 24-, and 96-well microtiter plates on orbital shakers. We also determined the specific power input using calorimetry and found that the power input is at the same order of magnitude for the six- and 96-well plates and the laboratory-scale stirred tank reactor, with 40 to 90 W/m(3) (Re' = 180 to 440), 40 to 140 W/m3 (Re' = 320 to 640), and 30 to 50 W/m(3) (Re = 4000 to 8500), respectively. All of these values are significantly below 450 to 2100 W/m(3) determined for the pilot-scale reactor. The hydrodynamic stress differs significantly between the different formats of MTPs, as the 96-well plates showed very low shear stress on the shaker with a shaking amplitude of 3 mm. Thus, the transfer of mixing conditions from the microtiter plate to small-scale and pilot-scale reactors must be undertaken with care. Our findings, especially the power input determined by the calorimetric method, show that the hydrodynamic conditions in laboratory- and pilot-scale reactors cannot be reached.

  5. Microtiter plate tests for segregation of bioluminescent bacteria.

    PubMed

    Šimkus, Remigijus; Meškienė, Rita; Ledas, Žilvinas; Baronas, Romas; Meškys, Rolandas

    2016-02-01

    It has been recently shown that bioluminescence imaging can be usefully applied to provide new insights into bacterial self-organization. In this work we employ bioluminescence imaging to record images of nutrient rich liquid cultures of the lux-gene reporter Escherichia coli in microtiter plate wells. The images show that patterns of inhomogenous bioluminescence form along the three-phase contact lines. The paper analyzes the dependencies of the average number of luminous aggregates (clouds) on various environmental factors. In particular, our results show that optimal (neutral) pH and high aeration rates determine the highest mean number of clouds, and that spatiotemporal patterns do not form in the pH buffered suspensions. In addition, a sigmoidal (switch-like) dependence of the number of aggregates on the rate of aeration was observed. The obtained bioluminescence imaging data was interpreted by employing the Keller-Segel-Fisher (KSF) model of chemotaxis and logistic growth, adapted to systems of metabolically flexible (two-state) bacteria. The modified KSF model successfully simulated the observed switch-like responses. The results of the microtiter plate tests and their simulations indicate that the segregation of bacteria with different activities proceeds in the three-phase contact line region.

  6. Scale-down of vinegar production into microtiter plates using a custom-made lid.

    PubMed

    Schlepütz, Tino; Büchs, Jochen

    2014-04-01

    As an important food preservative and condiment, vinegar is widely produced in industry by submerged acetic acid bacteria cultures. Although vinegar production is established on the large scale, up to now suitable microscale cultivation methods, e.g. using microtiter plates, are missing to enable high-throughput cultivation and to optimize fermentation conditions. In order to minimize evaporation losses of ethanol and acetic acid in a 48-well microtiter plate during vinegar production a new custom-made lid was developed. A diffusion model was used to calculate the dimensions of a hole in the lid to guarantee a suitable oxygen supply and level of ventilation. Reference fermentation was conducted in a 9-L bioreactor to enable the calculation of the proper cultivation conditions in the microtiter plate. The minimum dissolved oxygen tensions in the microtiter plate were between 7.5% and 23% of air saturation and in the same range as in the 9-L bioreactor. Evaporation losses of ethanol and acetic acid were less than 5% after 47 h and considerably reduced compared to those of microtiter plate fermentations with a conventional gas-permeable seal. Furthermore, cultivation times in the microtiter plate were with about 40 h as long as in the 9-L bioreactor. In conclusion, microtiter plate cultivations with the new custom-made lid provide a platform for high-throughput studies on vinegar production. Results are comparable to those in the 9-L bioreactor.

  7. Plasma-based surface modification of polystyrene microtiter plates for covalent immobilization of biomolecules.

    PubMed

    North, Stella H; Lock, Evgeniya H; Cooper, Candace J; Franek, James B; Taitt, Chris R; Walton, Scott G

    2010-10-01

    In recent years, polymer surfaces have become increasingly popular for biomolecule attachment because of their relatively low cost and desirable bulk physicochemical characteristics. However, the chemical inertness of some polymer surfaces poses an obstacle to more expansive implementation of polymer materials in bioanalytical applications. We describe use of argon plasma to generate reactive hydroxyl moieties at the surface of polystyrene microtiter plates. The plates are then selectively functionalized with silanes and cross-linkers suitable for the covalent immobilization of biomolecules. This plasma-based method for microtiter plate functionalization was evaluated after each step by X-ray photoelectron spectroscopy, water contact angle analysis, atomic force microscopy, and bioimmobilization efficacy. We further demonstrate that the plasma treatment followed by silane derivatization supports direct, covalent immobilization of biomolecules on microtiter plates and thus overcomes challenging issues typically associated with simple physisorption. Importantly, biomolecules covalently immobilized onto microtiter plates using this plasma-based method retained functionality and demonstrated attachment efficiency comparable to commercial preactivated microtiter plates.

  8. Microtiter plate transformation using the LiAc/SS carrier DNA/PEG method.

    PubMed

    Gietz, R Daniel; Schiestl, Robert H

    2007-01-01

    Here, we describe a protocol that has been adapted for the transformation of yeast cells in 96-well microtiter plates. This protocol can be tailored for multiple applications and is suitable for high-throughput applications. It can be completed in 2-3 h, once the yeast cells have been grown depending on the heat shock used.

  9. Comparative evaluation of phototrophic microtiter plate cultivation against laboratory-scale photobioreactors.

    PubMed

    Morschett, Holger; Schiprowski, Danny; Rohde, Jannis; Wiechert, Wolfgang; Oldiges, Marco

    2017-01-18

    Extended cultivation times, rendering phototrophic bioprocess development time inefficient, resulted in the recent development of micro-photobioreactors enabling accelerated process development. However, especially for laboratory photobioreactors, only little is known concerning the influence of design on process performance. Thus, the aim of the present investigation was to evaluate the scalability of a microtiter plate-based parallelized micro-photobioreactor against a representative set of established laboratory photobioreactors. Lipid production by Chlorella vulgaris was used as a model system. During exponential growth, the microtiter plate cultures achieved maximal growth rates of ca. 1.44 ± 0.02 day(-1) being in good agreement with the larger systems. Moreover, cultures in the micro-photobioreactor could be kept in the exponential phase up to the highest biomass concentrations most probably due to the beneficial light supply at this scale. Compared to the shake flask and test tube cultures, microtiter plate cultivation achieved an equivalent biomass yield, lipid content, and lipid fingerprint. In contrast, the flat-panel process resulted only in marginal productivity due to insufficient light supply. Thus, microtiter plates showed good scalability to the investigated laboratory photobioreactors as overall differences were rather small taking the differing scales into account.

  10. Development of a new microtiter plate format for clinically relevant assays.

    PubMed

    Piletska, Elena V; Piletsky, Stanislav S; Whitcombe, Michael J; Chianella, Iva; Piletsky, Sergey A

    2012-02-21

    A new format for the microtiter plate-based assays was proposed. The novelty involves the use of disk-shaped inserts for immobilization of biological and chemical reagents. The internal opening of the disks allows measurements of the reactions by standard microtiter plate readers without any additional steps involving liquid handling. Ideally the plate end-users just have to add the sample and take the measurement without any need of multiple reagent additions or transfer of the liquid to a different plate. The novel assay format also allows handling of reagents which are not soluble in an aqueous environment. As a proof of concept we describe here several model reactions which are compatible with microtiter plate format, such as monitoring enzymatic reactions catalyzed by glucose oxidase (GOx) and urease, measurements of proteins by BCA assay, analysis of pH, and concentration of antioxidants. The "mix and match" approach in the disk-shape format allows multiplexing and could be particularly useful for high throughput screening. One of the potential application areas for this novel assay format could be in a multianalyte system for measurement of clinically relevant analytes in primary care.

  11. Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate.

    PubMed

    Felten, C; Foret, F; Minarik, M; Goetzinger, W; Karger, B L

    2001-04-01

    This paper describes the design and application of instrumentation for automated high-throughput infusion ESI-mass spectrometry. The approach, based on a subatmospheric ESI interface, allows sample introduction from a commercially available microtiter plate without the need for a separate fluid delivery system. The microtiter plate was placed vertically on a three-dimensional translation stage in front of the sampling ESI interface. A single, 7-cm, 20-microm-i.d. fused-silica capillary (total volume, 70 nL), with a tapered tip, served as a combination of sample delivery and spraying capillary. The tapered tip of the capillary was enclosed in a subatmospheric chamber attached in front of the orifice of the mass spectrometer. The sample aspiration rate (flow rate) was regulated by computer-controlled pneumatic valves, which allowed fast switching of the pressure in the subatmospheric ESI chamber. A flow-through wash device was positioned between the microtiter plate and the ESI interface. This design allowed alternate filling of the capillary with (a) sample from the wells and (b) wash solution from the wash device. Sample turnaround times of 10 s/sample, with a 120-nL sample consumption/analysis, and a duty cycle (percentage of total analysis time spent acquiring data) of 40% were achieved. The infusion system was demonstrated in the analysis of preparative HPLC fractions from a small molecule combinatorial library.

  12. Adaptive Focused Acoustics (AFA) Improves the Performance of Microtiter Plate ELISAs.

    PubMed

    Green, David J; Rudd, Edwin A; Laugharn, James A

    2014-08-01

    We investigated the use of Adaptive Focused Acoustics (AFA) technology to improve the performance of microtiter plate enzyme-linked immunosorbent assays (ELISAs). Experiments were performed with commercially available AFA instrumentation and off-the-shelf 96-well microtiter plate sandwich ELISAs. AFA was applied over a range of acoustic energies, temperatures, and durations to the antigen/antibody binding step of an ELISA for measuring HIV-1 p24 in tissue culture samples. AFA-mediated antigen/antibody binding was enhanced up to 2-fold over passive binding at comparable temperatures and was superior or comparable at low temperature (8-10 °C) to passive binding at 37 °C. Lower nonspecific binding (NSB), lower inter- and intra-assay coefficients of variation (CVs), higher Z' factors, and lower limits of detection (LODs) were measured in AFA-mediated assays compared with conventional passive binding. In a more limited study, AFA enhancement of antigen/antibody binding and lower NSB was measured in an ELISA for measuring IGFBP-3 in human plasma. We conclude from this study that application of AFA to antigen/antibody binding steps in microtiter plate ELISAs can enhance key assay performance parameters, particularly Z' factors and LODs. These features render AFA-mediated binding assays potentially more useful in applications such as high-throughput screening and in vitro diagnostics than assays processed with conventional passive antigen/antibody binding steps.

  13. Quantification of biofilm in microtiter plates: overview of testing conditions and practical recommendations for assessment of biofilm production by staphylococci.

    PubMed

    Stepanović, Srdjan; Vuković, Dragana; Hola, Veronika; Di Bonaventura, Giovanni; Djukić, Slobodanka; Cirković, Ivana; Ruzicka, Filip

    2007-08-01

    The details of all steps involved in the quantification of biofilm formation in microtiter plates are described. The presented protocol incorporates information on assessment of biofilm production by staphylococci, gained both by direct experience as well as by analysis of methods for assaying biofilm production. The obtained results should simplify quantification of biofilm formation in microtiter plates, and make it more reliable and comparable among different laboratories.

  14. Improvement and scale-down of a Trichoderma reesei shake flask protocol to microtiter plates enables high-throughput screening.

    PubMed

    Giese, Heiner; Kruithof, Paulien; Meier, Kristina; Sieben, Michaela; Antonov, Elena; Hommes, Ronald W J; Büchs, Jochen

    2014-12-01

    Nowadays, high-throughput screening is essential for determining the best microbial strains and fermentation conditions. Although microtiter plates allow higher throughput in screening than shake flasks, they do not guarantee sufficient oxygen supply if operated at unsuitable conditions. This is especially the case in viscous fermentations, potentially leading to poor liquid movement and surface growth. Therefore, in this study, two aims were pursued. First, an industrial Trichoderma reesei shake flask protocol is improved with respect to oxygen supply and production. Second, this improved shake flask protocol is scaled down into microtiter plate under consideration of similar oxygen supply. For this purpose, the respiration activity monitoring system (RAMOS) was applied. An approach based on a sulfite system was introduced to ensure equal maximum oxygen transfer capacities (OTRmax) in microtiter plates and shake flasks. OTRmax-values of 250 mL shake flasks and 24-well microtiter plates were determined in a wide range of operating conditions. These sulfite datasets were used to identify operating conditions leading to the same oxygen supply for T. reesei in shake flasks and 24-well microtiter plates. For 24-well microtiter plates, the shake flask OTRmax of 20 mmol/L/h of an industrial protocol was obtained under the following optimal operating conditions: 1 mL filling volume per well, 200 rpm shaking frequency and 50 mm shaking diameter. With these conditions almost identical oxygen transfer rates and product concentrations were measured in both scales. The proposed approach is a fast and accurate means to scale-down established screening procedures into microtiter plates to achieve high-throughput.

  15. A microtiter plate assay for factor XIII A-chain-fibrin interactions.

    PubMed

    Achyuthan, K E; Santiago, M A; Greenberg, C S

    1994-05-15

    Factor XIII A-chain-fibrin interactions regulate factor XIIIa formation and fibrin cross-linking. A microtiter plate assay was developed for studying these interactions. Microtiter plate wells were coated with fibrinogen and converted to fibrin by thrombin. After blocking the wells with bovine serum albumin, factor XIII A-chain was added and binding was monitored by incubating first with anti-factor XIII followed by anti-rabbit IgG-alkaline phosphatase. Enzymatic hydrolysis of p-nitrophenyl phosphate was quantitated by the absorbance at 405 nm. BInding was specific, sensitive, rapid, saturable, and reversible, requiring only nanograms of either factor XIII or fibrin. Binding was time- and concentration-dependent and independent of divalent cations. The bound material was identified as factor XIII A-chain by sodium dodecylsulfate-polyacrylamide gel electrophoresis and immunoblotting. Factor XIII binding was inhibited > 75% by 250 mM sodium chloride or 250 nM anti-factor XIII IgG. The method was also suitable for demonstrating binding using 0.8% plasma or with r-factor XIII expressed in Saccharomyces cerevisiae or Escherichia coli. This method is suitable for identifying the binding sites that are important for plasma factor XIII activation and factor XIIIa activity.

  16. A novel automated electrochemical ascorbic acid assay in the 24-well microtiter plate format.

    PubMed

    Intarakamhang, Sireerat; Leson, Christian; Schuhmann, Wolfgang; Schulte, Albert

    2011-02-14

    Automatic ascorbic acid (AA) voltammetry was established in 24-well microtiter plates. The assay used a movable assembly of a pencil rod working, an Ag/AgCl reference and a Pt counter electrode with differential pulse voltammetry (DPV) for concentration-dependent current generation. A computer was in command of electrode (z) and microtiter plate (x, y) positioning and timed potentiostat operation. Synchronization of these actions supported sequential approach of all wells and subsequent execution of electrode treatment procedures or AA voltammetry at defined intervals in a measuring cycle. DPV in well solutions offered a linear current/concentration range between 0.1 and 8.0 mM, a sensitivity of about 1 μA mM(-1) AA, and a detection limit of 50 μM. When used with a calibration curve or standard addition, automated voltammetry of samples with added known amounts of AA demonstrated good recovery rates. Also, the assay achieved the accurate determination of the AA content of vitamin C tablets, a fruit juice and an herbal tea extract. Robotic AA voltammetry has the advantage of conveniently handling multiple samples in a single measuring run without the continuous attention of laboratory personnel. It is a good option when the goal is cost-effective AA screening of sample libraries and has potential for applications in health care and the food processing, cosmetic and pharmaceutical industries.

  17. Microtiter plates versus stirred mini-bioreactors in biocatalysis: a scalable approach.

    PubMed

    Nunes, Mário A P; Fernandes, Pedro C B; Ribeiro, Maria H L

    2013-05-01

    To place the application of miniaturized vessels as microbioreactors on a firm footing, focus has been given to engineering characterization. Studies on this matter have mostly involved carrier-free biological systems, while support-based systems have been overlooked. The present work aims to contribute to fill in such gap. Thus, it intended to establish a robust scaled down approach to identify and optimize relevant operational conditions of naringin hydrolysis by naringinase in PVA lens-shaped particles. The influence of geometric and dynamic (viz. Reynolds number) parameters was evaluated. Naringin hydrolysis in round, flat bottom MTP proved more effective than in square, pyramidal bottom. The bioconversion at MTP and stirred tank reactors scales showed that, given the 12.5-fold scale difference was in agreement between the bioconversion rates. The external mass transfer resistances were negligible as deduced from Damkohler modulus ≤1. The bioconversion was effectively scaled-up 200-fold from shaken microtiter plates to stirred tank reactors.

  18. A rapid microtiter plate method for the detection of lysozyme release from human neutrophils.

    PubMed

    Moreira-Ludewig, R; Healy, C T

    1992-04-01

    An improved method was devised to measure lysozyme secreted from human neutrophils [polymorphonuclear leukocyte (PMN)] using a microtiter plate reader capable of analyzing enzyme kinetics. The assay is an adaptation of the classical photometric method which detects changes in the turbidity of a bacterial suspension, Micrococcus lysodeikticus, caused by the enzymatic activity of lysozyme. A standard curve using chicken egg white lysozyme was generated, and activity was detectable between the range of 1 and 100 ng/ml. Leukotriene B4 (LTB4)-induced lysozyme release from human PMN was comparable in both the standard assay and the microtiter plate adaptation with EC50 values of 6.5 and 7.2 nM, respectively. Other select stimuli and their receptor antagonists were also used to evaluate the method. Dose-response curves for chemotactic hexapeptide (CHP), recombinant human C5a (rhC5a), and platelet-activating factor (PAF) resulted in EC50 values of 0.14, 0.80, and 542.00 nM, respectively. Inhibition of lysozyme release was studied using receptor antagonists N-t-Boc-L-methionyl-L-leucyl-L-phenylalanine (N-t-Boc), LY223982, and protamine, which are putative inhibitors of formyl peptides (i.e., CHP), LTB4, and C5a, respectively. N-t-Boc inhibited CHP-induced (0.2 nM) enzyme release with an IC50 of 2 microM; LY223982 blocked LTB4-induced (20 nM) release resulting in an IC50 of 52 nM; and protamine inhibited rhC5a-induced (1.5 nM) release with an IC50 of 2 microM. Further studies revealed that CHP, LTB4, and rhC5a were selectively inhibited by their respective antagonists, albeit LY223982 and protamine were also weak inhibitors of CHP and LTB4, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. In vitro stimulation of bovine peripheral blood lymphocytes: comparison of round- and flat-bottom microtiter plates for detection of tuberculin hypersensitivity.

    PubMed

    Sloane, E D; Muscoplat, C C; Kaneene, J M; Klausner, D J; Thoen, C O; Johnson, D W

    1978-02-01

    Lymphocytes from Mycobacterium bovis-sensitized and normal cattle were cultured in round- and/or flat-bottom microtiter plates and stimulated with M. bovis purified protein derivative (PPD) tuberculin. Blastogenic responses of lymphocytes from M. bovis-sensitized cattle to PPD cultured in round-bottom plates were significantly greater than those of lymphocytes cultured in flat-bottom microtiter plates. Normal lymphocytes of nonsensitized cattle were not stimulated by PPD in either round- or flat-bottom microtiter plates. Kinetics of lymphocyte responses in round-bottom plates are presented.

  20. Optimization of Salmonella Typhi biofilm assay on polypropylene microtiter plates using response surface methodology.

    PubMed

    Ganjali Dashti, M; Abdeshahian, P; Sudesh, K; Phua, K K

    2016-01-01

    The objective of this study was to develop an optimized assay for Salmonella Typhi biofilm that mimics the environment of the gallbladder as an experimental model for chronic typhoid fever. Multi-factorial assays are difficult to optimize using traditional one-factor-at-a-time optimization methods. Response surface methodology (RSM) was used to optimize six key variables involved in S. Typhi biofilm formation on cholesterol-coated polypropylene 96-well microtiter plates. The results showed that bile (1.22%), glucose (2%), cholesterol (0.05%) and potassium chloride (0.25%) were critical factors affecting the amount of biofilm produced, but agitation (275 rpm) and sodium chloride (0.5%) had antagonistic effects on each other. Under these optimum conditions the maximum OD reading for biofilm formation was 3.4 (λ600 nm), and the coefficients of variation for intra-plate and inter-plate assays were 3% (n = 20) and 5% (n = 8), respectively. These results showed that RSM is an effective approach for biofilm assay optimization.

  1. A rapid sandwich immunoassay for human fetuin A using agarose-3-aminopropyltriethoxysilane modified microtiter plate.

    PubMed

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2015-07-09

    A rapid sandwich immunoassay (IA) with enhanced signal response for human fetuin A (HFA) was developed by modifying the surface of a KOH-treated polystyrene microtiter plate (MTP) with agarose and 3-aminopropyltriethoxysilane (APTES). The agarose-APTES complex binds covalently to the hydroxyl moiety of the MTP plate to serve as a binding platform for bioconjugation of EDC-activated anti-HFA antibody (Ab) via carbodiimide coupling. The one-step kinetics-based sandwich enzyme-linked immunosorbent assay (ELISA) enabled the detection of HFA in 30 min with a limit of detection (LOD) and a linear range of 0.02 ng mL(-1) and 1-243 ng mL(-1), respectively. It detected HFA spiked in diluted human whole blood and serum, and HFA in ethylenediaminetetraacetic acid (EDTA)-plasma of patients with high precision similar to that of conventional ELISA. The anti-HFA Ab-bound agarose-functionalized MTPs retained their functional activity after 6 weeks of storage in 0.1 M PBS, pH 7.4 at 4 °C.

  2. Spectrophotometric determination of various polyanions with polymeric film optodes using microtiter plate reader.

    PubMed

    Dürüst, Nedime; Meyerhoff, Mark E; Unal, Nazangül; Naç, Sibel

    2011-08-05

    Polycation-sensitive membrane optodes based on the chromoionophore 2',7'-dichlorofluorescein octadecylester (DCFOE) have previously been developed and used for determination of heparin via a titrimetric method. In this study, it is shown that some other important polyanions such as PPS (pentosan polysulfate), DNA, xanthan, Na-alginate, and carrageenan (food additive) can also be readily determined by using DCFOE-based microtiter plate-format optodes (MPOs) and polycationic titrants that bind these polyanionic species. The optical sensors are prepared with poly(vinyl chloride) (PVC), polyurethane (PU), bis(2-ethylhexyl)sebacate (DOS), and 2',7'-dichlorofluorescein octadecylester (DCFOE) and exhibit reproducible and sensitive absorbance changes in response to the varying polycationic titrant concentrations. Three different polycations; protamine, poly-l-lysine and poly-l-arginine, are employed as titrants. The method has a detection limit of 1 μg mL(-1), and a dynamic range of 1-40 μg mL(-1). After the quantitative determinations are successfully demonstrated in buffered solutions, similar titrations are also performed in real samples. The method is validated by recovery studies in these samples. The average polyanion recoveries were quantitative [99.7(±1.3) % for pastry cream with vanillin (protamine titrant); 100.4 (±3.3) % for pastry gel with strawberry(PLA titrant), and 102.9(±2.0) % for pastry gel with strawberry (PLL titrant)].

  3. A colorimetric method for the measurement of platelet adhesion in microtiter plates.

    PubMed

    Bellavite, P; Andrioli, G; Guzzo, P; Arigliano, P; Chirumbolo, S; Manzato, F; Santonastaso, C

    1994-02-01

    A procedure for the determination of the adhesion of human platelets to protein-coated culture microwells was developed. The number of platelets was quantitated by measuring the activity of acid phosphatase, a platelet enzyme whose activity is stable independently of platelet stimulation and is not released. Isolated and washed platelets were incubated in 96-well microtiter plates with flat-bottom wells that had been precoated with various compounds, including collagen, fibrinogen, human plasma, and human albumin. At the end of incubation (optimal time: 40-60 min), nonadherent platelets were washed out, adherent platelets were solubilized with Triton X-100, and the acid phosphatase activity was measured by using the substrate p-nitrophenyl phosphate. The p-nitrophenol produced was measured with a microplate reader at 405 nm and the percentage of adhesion was calculated with reference to known platelet standards. ADP and thrombin stimulated platelet adhesion in a dose-dependent manner to fibrinogen and human plasma, but not to human albumin. Platelets adhered to collagen even in the absence of stimulants. Simultaneous evaluation of adhesion and aggregation demonstrated that with ADP as stimulus, but not with thrombin, the two platelet responses were dissociated. Microscopic examination of culture wells showed that most of platelets adhered as single cells and not as aggregates. The sensitivity of this method allowed the assay of platelet adhesion by using only 2.5 x 10(5) platelets/well.

  4. Development of a fluorometric microtiter plate based enzyme assay for MPS IVA (Morquio type A) using dried blood spots.

    PubMed

    Ullal, Anirudh J; Millington, David S; Bali, Deeksha S

    2014-01-01

    Mucopolysaccharidosis type IVA or Morquio type-A disease is a hereditary lysosomal storage disorder caused by deficient activity of the lysosomal enzyme N-acetylgalactosamine-6-sulfate sulfatase (GALNS). The disease is caused by lysosomal accumulation of unprocessed glycosaminoglycans (GAGs) that manifests with severe to mild skeletal and cardiopulmonary abnormalities. We have developed a modified microtiter plate-based enzyme activity assay using dried blood spots and a fluorescent substrate for measuring specific GALNS activity to identify patients with MPS IVA.

  5. Evaluation of various plastic microtiter plates with measles, toxoplasma, and gamma globulin antigens in enzyme-linked immunosorbent assays.

    PubMed Central

    Shekarchi, I C; Sever, J L; Lee, Y J; Castellano, G; Madden, D L

    1984-01-01

    Seventeen lots of microtiter plates which differed in lot, batch, plastic type, or manufacturer were evaluated as solid-phase carriers in enzyme-linked immunosorbent assays for antibodies to measles, toxoplasma, and human gamma globulin. Most plates of polystyrene or polyvinyl chloride were found to give acceptable binding. The final choice depended on the antigen to be attached. Variations in binding between lots, batches, and types of plastic were found. Well-to-well variation was found to be of greater statistical significance than edge effect and should be a consideration in selection of a plate lot for enzyme-linked immunosorbent assays. Lots of plates should be pretested by the investigator to determine whether there is good binding of the antigen to be used and whether there is low plate-to-plate and well-to-well variation. PMID:6199371

  6. Comparative Evaluation of Colorimetric Microtiter Plate Systems for Detection of Herpes Simplex Virus in Cerebrospinal Fluid

    PubMed Central

    Tang, Yi-Wei; Rys, Paul N.; Rutledge, Barbara J.; Mitchell, P. Shawn; Smith, Thomas F.; Persing, David H.

    1998-01-01

    In the past few years, application of the PCR to the detection of herpes simplex virus (HSV) DNA in the cerebrospinal fluid (CSF) from patients with encephalitis and meningitis has become standard laboratory practice. However, from an operational perspective, the true diagnostic value of PCR in this setting is yet to be realized because most laboratories subject the amplification products to lengthy probe hybridization procedures by Southern blotting. As alternatives to Southern blotting, we evaluated colorimetric microtiter plate (MTP) systems from ViroMed Laboratories, Inc. (PrimeCapture), CPG, Inc. (Quanti-PATH), and Incstar Corp. (GEN-ETI-K), in addition to a system developed at the Mayo Clinic with the PCR ELISA system (Boehringer Mannheim Corp.). We tested PCR products from 86 clinical CSF specimens submitted to our Molecular Microbiology Laboratory. The CSF specimens used had to have sufficient volume for comparative analysis. By conventional Southern blotting methods, 54 were positive and 32 were negative for HSV DNA. Compared with Southern blotting, the sensitivity and specificity were 63.0 and 100.0%, respectively, for the PrimeCapture system, 98.2 and 96.9%, respectively, for the Quanti-PATH system, 98.2 and 100.0%, respectively, for the GEN-ETI-K system, and 100.0 and 96.9%, respectively, for the Mayo system. All four MTP systems had turnaround times 12 to 24 h less than that for Southern blotting. There were no significant differences in costs or technologist time between the Mayo system and Southern blotting. Other features of the Mayo system include type-specific genotypic identification of HSV and the potential for determination of drug resistance by DNA sequencing. Overall, we found that colorimetric MTP systems were likely to improve test turnaround times and patient care at no additional cost. PMID:9705419

  7. Fluorescence assay for mitochondrial permeability transition in cardiomyocytes cultured in a microtiter plate.

    PubMed

    Christensen, Marie Louise Muff; Braunstein, Thomas Hartig; Treiman, Marek

    2008-07-01

    Mitochondrial permeability transition pore (MPTP) is a voltage-dependent, large-conductance channel of the inner mitochondrial membrane with an important role in a range of pathophysiological conditions. To facilitate studies of pharmacological pore modulation, we describe an assay in a model using neonatal cardiomyocytes in a 96-well microtiter plate format. In the presence of mitochondrial membrane potential Delta Psi m, accumulation of rhodamine-123 in mitochondria (40,000 cells/well, 2.6 microM rhodamine-123) caused fluorescence signal quenching. Following substitution of dye-free buffer, dequenching occurred on the distribution of rhodamine-123 into the extracellular volume. The addition of a small buffer volume containing digitonin (final concentration 10 microg/ml) and Ca(2+) (final concentrations up to 100 microM free Ca(2+)) caused dequenching (Delta F) due to Delta Psi m dissipation by MPTP, as evidenced by inhibition in the presence of cyclosporin A (0.2-2 microM) and facilitation by pH 6.2. Delta F due to Delta Psi m-dissipating agent carbonyl cyanide p-trifluoromethoxyphenylhydrazone (FCCP) or alamethicin (10 microM) was insensitive to either pH or cyclosporin A. Inhibition of Ca(2+)-induced (but not of FCCP- or alamethicin-induced) Delta F by glycogen synthase kinase 3beta (GSK3 beta) antagonist SB216763 and adenosine, acting at the level of intracellular signaling and plasma membrane receptors, respectively, is shown to illustrate potential applications of this assay. Limitation of the assay to cells with energized mitochondria is stressed.

  8. Oxygen transfer rates in shaken culture vessels from Fernbach flasks to microtiter plates.

    PubMed

    Running, Jeffrey A; Bansal, Karan

    2016-08-01

    By a sulfite oxidation method, oxygen transfer rates (OTRs) were determined in 11 types of culture vessels from 2.8-L Fernbach (FB) flasks to 96-, 48-, and 24-well square deepwell microtiter plates (MTPs). OTRs ranged from 140 mM/h in 250-mL Ultrayield™ flasks shaken at 300 rpm with a 50 mm diameter shaker throw to 5 mM/h in unbaffled FBs shaken at 200 rpm with a 25 mm throw. Baffles in FBs increased OTRs 6-12-fold under various shaking conditions, and up to five-fold in 250-mL flasks, depending on the type of baffles. Corner-baffling was superior to bottom-baffling in glass, 250-mL flasks. In MTPs, OTRs increased with increasing well size and decreasing fill volume. At 50 mm throw and 300 rpm, 24-well MTPs had OTRs comparable to corner-baffled, 250-mL flasks (∼100 mM/h). The OTRs in unbaffled flasks were relatively insensitive to shaking conditions, increasing less than two-fold between the most modest and the most vigorous conditions. There was no consistency across vessels as to whether the alternate incubation conditions of 70 mm throw and 250 rpm produced higher OTRs than the 50 mm throw and 300 rpm regimen. No increase in OTR was seen in any MTP when the cover hole diameter was increased beyond 4.5 mm. OTRs decreased as viscosity increased, falling smoothly in unbaffled flasks and 24-well MTPs, but 48-well and 96-well MTPs showed precipitous OTR drops as viscosity increased. Matching the OTRs of screening vessels to the oxygen uptake rates of microbial cultures can greatly reduce the number of false positive strains that are forwarded from microbial screens. Biotechnol. Bioeng. 2016;113: 1729-1735. © 2016 Wiley Periodicals, Inc.

  9. Optimization of 384-well Luminex Immunoassays on the FlexMAP 3D System for Routine Analyte Quantitation from Commercial Kits

    PubMed Central

    Pergande, Melissa; Pithadia, Ravi; Borgia, Jeffrey A.; Fhied, Cristina

    2014-01-01

    INTRODUCTION: The Luminex immunobead platform offers the benefits of ELISA-based assays, but also permits higher throughput, increased flexibility, reduced sample volume, and lower cost when evaluation of multiple analytes is necessary. The FlexMap 3D system is a compact, high bead throughput instrument which can read up to 500 different bead regions from a single sample in a 96 or 384-well plate format. Commercially-available kits for the measurement of protein analytes are currently only available in the 96-well plate format. The objective of this study was to adapt and validate the commonly used 96-well plate protocols to the 384-well plate format with equivalent or improved test performance characteristics. METHODS: A laboratory-developed 96-well plate assay protocol for Vimentin autoantibody quantitation was translated and optimized for a 384-well plate format. Assay sensitivity was evaluated by comparing the results from two commercially available kits (Human IGF Binding Proteins 1-7 and Human IGF I/II), first employing the traditional 96-well plate format and subsequently using the newly optimized 384-well plate format. RESULTS: Conversion from the 96 to 384-well plate format for our Vimentin autoantibody assay revealed comparable sensitivity, while consuming only about a quarter of the reagents and specimen. Results from the IGF-I assay revealed approximately equivalent sensitivity (±2.4%), whereas IGF-II showed a significant increase in sensitivity (17.7%), both when the 96 and 384-well plate formats were ran concomitantly. No significant alterations in assay range, recovery or precision were otherwise noted. CONCLUSION: In this study, we have demonstrated that the conversion of a 96 to 384-well plate format was developed and validated successfully. When employing our optimized 384-well plate format, we found that nearly 4 times as many samples can be ran additionally with one commercially available kit, saving in not only cost but also sample size.

  10. Parallel online multi-wavelength (2D) fluorescence spectroscopy in each well of a continuously shaken microtiter plate.

    PubMed

    Ladner, Tobias; Beckers, Mario; Hitzmann, Bernd; Büchs, Jochen

    2016-12-01

    Small-scale high-throughput screening devices are becoming increasingly important in bioprocess development. Conventional dipping probes for process monitoring are often too large to be used in these devices. Thus, optical measurements are often the method of choice. Even some parameters that cannot directly be measured by fluorescence become accessible via sensitive fluorescence dyes. However, not all compounds of interest are measurable by this technique. Recent studies applying multi-wavelength (2D) fluorescence spectroscopy in combination with chemometrics have shown that information on numerous analytes is obscured by the fluorescence data. Hitherto, this measurement technique has only been available on the scale of stirred tank fermenters. This work introduces a new device for multi-wavelength (2D) fluorescence spectroscopy in each well of a continuously shaken microtiter plate. Using a combination of spectrograph and CCD detector, the required time per measurement cycle in a 48-well microtiter plate was 0.5 h. Cultures of Hansenula polymorpha and Escherichia coli are monitored. The concentrations of glycerol, glucose and acetate as well as pH are determined using partial least square (PLS) models. Because a pH-sensitive fluorescence dye was not required, no dependency of the pKa of a fluorescence dye exists, and measurements in the low pH range can be obtained.

  11. Quasi-continuous combined scattered light and fluorescence measurements: a novel measurement technique for shaken microtiter plates.

    PubMed

    Samorski, M; Müller-Newen, G; Büchs, J

    2005-10-05

    A novel quasi-continuous on-line measuring technique for shaken microtiter plates is presented. Light scattering as well as intracellular and/or protein fluorescence (e.g. NADH, YFP) is measured during the shaking procedure, thus allowing a process monitoring of 96 different simultaneous cultures in a microtiter plate. In contrast to existing measurement techniques, the shaking process does not have to be stopped to take the measurements, thus avoiding the corresponding interruption of the cultures' oxygen supply and any unpredictable effects on the cultures. Experiments were conducted with E. coli in LB, TB, and MOPS minimal medium and V. natriegens in modified LB and TB media. Intensity curves of scattered light and NADH fluorescence were used to distinguish different lag phases, growth velocities, or inoculation densities. Data from this new method corresponded well to the off-line measured optical densities and to the oxygen transfer rates of cultures run in simultaneously conducted shake flask experiments at equivalent oxygen transfer capacities. With the aid of yellow fluorescence protein fused to interleukin-6 the optimal induction time of an expressing E. coli strain could be determined by on-line monitoring of product formation. Thus, this measuring technique enables the researcher to evaluate and to discriminate different cultures on a screening level and to improve screening conditions, process development and scale-up.

  12. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  13. Robo-Lector – a novel platform for automated high-throughput cultivations in microtiter plates with high information content

    PubMed Central

    Huber, Robert; Ritter, Daniel; Hering, Till; Hillmer, Anne-Kathrin; Kensy, Frank; Müller, Carsten; Wang, Le; Büchs, Jochen

    2009-01-01

    Background In industry and academic research, there is an increasing demand for flexible automated microfermentation platforms with advanced sensing technology. However, up to now, conventional platforms cannot generate continuous data in high-throughput cultivations, in particular for monitoring biomass and fluorescent proteins. Furthermore, microfermentation platforms are needed that can easily combine cost-effective, disposable microbioreactors with downstream processing and analytical assays. Results To meet this demand, a novel automated microfermentation platform consisting of a BioLector and a liquid-handling robot (Robo-Lector) was sucessfully built and tested. The BioLector provides a cultivation system that is able to permanently monitor microbial growth and the fluorescence of reporter proteins under defined conditions in microtiter plates. Three examplary methods were programed on the Robo-Lector platform to study in detail high-throughput cultivation processes and especially recombinant protein expression. The host/vector system E. coli BL21(DE3) pRhotHi-2-EcFbFP, expressing the fluorescence protein EcFbFP, was hereby investigated. With the method 'induction profiling' it was possible to conduct 96 different induction experiments (varying inducer concentrations from 0 to 1.5 mM IPTG at 8 different induction times) simultaneously in an automated way. The method 'biomass-specific induction' allowed to automatically induce cultures with different growth kinetics in a microtiter plate at the same biomass concentration, which resulted in a relative standard deviation of the EcFbFP production of only ± 7%. The third method 'biomass-specific replication' enabled to generate equal initial biomass concentrations in main cultures from precultures with different growth kinetics. This was realized by automatically transferring an appropiate inoculum volume from the different preculture microtiter wells to respective wells of the main culture plate, where

  14. Development of a microtiter plate-based glycosaminoglycan array for the investigation of glycosaminoglycan-protein interactions.

    PubMed

    Marson, Andrew; Robinson, David E; Brookes, Patrick N; Mulloy, Barbara; Wiles, Michelle; Clark, Simon J; Fielder, Helen L; Collinson, Lisa J; Cain, Stuart A; Kielty, Catherine M; McArthur, Sally; Buttle, David J; Short, Robert D; Whittle, Jason D; Day, Anthony J

    2009-12-01

    The interactions of glycosaminoglycans (GAGs) with proteins underlie a wide range of important biological processes. However, the study of such binding reactions has been hampered by the lack of a simple frontline analysis technique. Previously, we have reported that cold plasma polymerization can be used to coat microtiter plate surfaces with allyl amine to which GAGs (e.g., heparin) can be noncovalently immobilized retaining their ability to interact with proteins. Here, we have assessed the capabilities of surface coats derived from different ratios of allyl amine and octadiene (100:0 to 0:100) to support the binding of diverse GAGs (e.g., chondroitin-4-sulfate, dermatan sulfate, heparin preparations, and hyaluronan) in a functionally active state. The Link module from TSG-6 was used as a probe to determine the level of functional binding because of its broad (and unique) specificity for both sulfated and nonsulfated GAGs. All of the GAGs tested could bind this domain following their immobilization, although there were clear differences in their protein-binding activities depending on the surface chemistry to which they were adsorbed. On the basis of these experiments, 100% allyl amine was chosen for the generation of a microtiter plate-based "sugar array"; X-ray photoelectron spectroscopy revealed that similar relative amounts of chondroitin-4-sulfate, dermatan sulfate, and heparin (including two selectively de-sulfated derivatives) were immobilized onto this surface. Analysis of four unrelated proteins (i.e., TSG-6, complement factor H, fibrillin-1, and versican) illustrated the utility of this array to determine the GAG-binding profile and specificity for a particular target protein.

  15. Microtiter plate bioassay to monitor the interference of antibiotics with the lipid II cycle essential for peptidoglycan biosynthesis.

    PubMed

    Burkard, Michael; Stein, Torsten

    2008-09-01

    Specific drug-sensing systems that coordinate appropriate genetic responses assure the survival of microorganisms in the presence of antibiotics. We report on the development and application of a microtiter plate-based bioassay for the identification of antibiotics interfering with the lipid II cycle essential for peptidoglycan biosynthesis. A Bacillus subtilis reporter strain sensing specifically lipid II - interfering cell wall biosynthesis stress (T. Mascher, S.L. Zimmer, T.-A. Smith and J. Helmann, Antibiotic-inducible promoter regulated by the cell envelope stress-sensing two-component system LiaRS of Bacillus subtilis; Antimicrob. Agents Chemother., Vol 48 (2004) pp. 2888-2896) was analyzed in the presence of different lantibiotics. We could show dose-dependent cell wall biosynthesis stress of reporter cells in response to the action of the lantibiotics subtilin produced by B. subtilis, epidermin and gallidermin of Staphylococcus epidermidis or S. gallinarum, respectively, in both, agar-plate and liquid culture-based assays. Surprisingly, also cinnamycin of Streptomyces cinnamoneus cinnamoneus), previously known to bind specifically to phosphatidylethanolamin of biological membranes, provoked strong cell wall biosynthetic stress. Our results show that our system can be used for screening purposes, for example to discover novel inhibitors of cell wall biosynthesis.

  16. An Immunoassay for Dibutyl Phthalate Based on Direct Hapten Linkage to the Polystyrene Surface of Microtiter Plates

    PubMed Central

    Wei, Chenxi; Ding, Shumao; You, Huihui; Zhang, Yaran; Wang, Yao; Yang, Xu; Yuan, Junlin

    2011-01-01

    Background Dibutyl phthalate (DBP) is predominantly used as a plasticizer inplastics to make them flexible. Extensive use of phthalates in both industrial processes and other consumer products has resulted in the ubiquitous presence of phthalates in the environment. In order to better determine the level of pollution in the environment and evaluate the potential adverse effects of exposure to DBP, immunoassay for DBP was developed. Methodology/Principal Findings A monoclonal antibody specific to DBP was produced from a stable hybridoma cell line generated by lymphocyte hybridoma technique. An indirect competitive enzyme-linked immunosorbent assay (icELISA) employing direct coating of hapten on polystyrene microtiter plates was established for the detection of DBP. Polystyrene surface was first oxidized by permanganate in dilute sulfuric acid to generate carboxyl groups. Then dibutyl 4-aminophthalate, which is an analogue of DBP, was covalently linked to the carboxyl groups of polystyrene surface with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC). Compared with conjugate coated format (IC50 = 106 ng/mL), the direct hapten coated format (IC50 = 14.6 ng/mL) improved assay sensitivity after careful optimization of assay conditions. The average recovery of DBP from spiked water sample was 104.4% and the average coefficient of variation was 9.95%. Good agreement of the results obtained by the hapten coated icELISA and gas chromatography-mass spectrometry further confirmed the reliability and accuracy of the icELISA for the detection of DBP in certain plastic and cosmetic samples. Conclusions/Significance The stable and efficient hybridoma cell line obtained is an unlimited source of sensitive and specific antibody to DBP. The hapten coated format is proposed as generally applicable because the carboxyl groups on modified microtiter plate surface enables stable immobilization of aminated or hydroxylated hapten with EDC. The developed hapten

  17. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive

  18. Development of resazurin-based assay in 384-well format for high throughput whole cell screening of Trypanosoma brucei rhodesiense strain STIB 900 for the identification of potential anti-trypanosomal agents.

    PubMed

    Lim, Kah Tee; Zahari, Zuriati; Amanah, Azimah; Zainuddin, Zafarina; Adenan, Mohd Ilham

    2016-03-01

    To accelerate the discovery of novel leads for the treatment of Human African Trypanosomiasis (HAT), it is necessary to have a simple, robust and cost-effective assay to identify positive hits by high throughput whole cell screening. Most of the fluorescence assay was made in black plate however in this study the HTS assay developed in 384-well format using clear plate and black plate, for comparison. The HTS assay developed is simple, sensitive, reliable and reproducible in both types of plates. Assay robustness and reproducibility were determined under the optimized conditions in 384-well plate was well tolerated in the HTS assay, including percentage of coefficient of variation (% CV) of 4.68% and 4.74% in clear and black 384-well plate, signal-to-background ratio (S/B) of 12.75 in clear 384-well plate and 12.07 in black 384-well plate, Z' factor of 0.79 and 0.82 in clear 384-well plate and black 384-well plate, respectively and final concentration of 0.30% dimethylsulfoxide (DMSO) in both types of plate. Drug sensitivity was found to be comparable to the reported anti-trypanosomal assay in 96-well format. The reproducibility and sensitivity of this assay make it compliant to automated liquid handler use in HTS applications.

  19. Permeability of currently available microtiter plate sealing tapes fail to fulfil the requirements for aerobic microbial cultivation.

    PubMed

    Sieben, Michaela; Giese, Heiner; Grosch, Jan-Hendrik; Kauffmann, Kira; Büchs, Jochen

    2016-12-01

    Microtiter plate (MTP) sealing tapes are commonly applied in bioprocess development and high throughput screening in order to maintain sterile conditions and avoid liquid evaporation. However, only a few of the commercially available sealing tapes are adequately characterized to guarantee both minimal evaporation and sufficient oxygen supply for aerobic cultivation. Therefore, 12 commercially available sealing tapes are analyzed concerning their water vapor and oxygen permeability. The water vapor permeability is assessed by gravimetrically quantifying the liquid loss due to evaporation. Thereby, the sealing tapes are revealed significant differences. Highly permeable sealing tapes are resulted in liquid loss of up to 25% of the initial filling volume after 8 h at 37°C and 45% ambient humidity. Additionally, the tremendous impact of evaporative cooling on the liquid temperature is detected discovering deviations of up to 3.8°C from the set temperature. The oxygen permeability is assessed by measuring the oxygen transfer rate (OTR). Three out of the 12 tested sealing tapes are impermeable to oxygen while the remaining sealing tapes are ensured sufficient oxygen supply. As a result, all examined sealing tapes are inadequate with respect to either water or oxygen permeation. Based on these novel experimental results, prospective improvements of MTP sealing tapes are presented using a model approach.

  20. Convenient microtiter plate-based, oxygen-independent activity assays for flavin-dependent oxidoreductases based on different redox dyes

    PubMed Central

    Brugger, Dagmar; Krondorfer, Iris; Zahma, Kawah; Stoisser, Thomas; Bolivar, Juan M; Nidetzky, Bernd; Peterbauer, Clemens K; Haltrich, Dietmar

    2014-01-01

    Flavin-dependent oxidoreductases are increasingly recognized as important biocatalysts for various industrial applications. In order to identify novel activities and to improve these enzymes in engineering approaches, suitable screening methods are necessary. We developed novel microtiter-plate-based assays for flavin-dependent oxidases and dehydrogenases using redox dyes as electron acceptors for these enzymes. 2,6-dichlorophenol-indophenol, methylene green, and thionine show absorption changes between their oxidized and reduced forms in the visible range, making it easy to judge visually changes in activity. A sample set of enzymes containing both flavoprotein oxidases and dehydrogenases – pyranose 2-oxidase, pyranose dehydrogenase, cellobiose dehydrogenase, d-amino acid oxidase, and l-lactate oxidase – was selected. Assays for these enzymes are based on a direct enzymatic reduction of the redox dyes and not on the coupled detection of a reaction product as in the frequently used assays based on hydrogen peroxide formation. The different flavoproteins show low Michaelis constants with these electron acceptor substrates, and therefore these dyes need to be added in only low concentrations to assure substrate saturation. In conclusion, these electron acceptors are useful in selective, reliable and cheap MTP-based screening assays for a range of flavin-dependent oxidoreductases, and offer a robust method for library screening, which could find applications in enzyme engineering programs. PMID:24376171

  1. Colorimetric microtiter plate receptor-binding assay for the detection of freshwater and marine neurotoxins targeting the nicotinic acetylcholine receptors

    USGS Publications Warehouse

    Rubio, Fernando; Kamp, Lisa; Carpino, Justin; Faltin, Erin; Loftin, Keith A.; Molgó, Jordi; Aráoz, Rómulo

    2014-01-01

    Anatoxin-a and homoanatoxin-a, produced by cyanobacteria, are agonists of nicotinic acetylcholine receptors (nAChRs). Pinnatoxins, spirolides, and gymnodimines, produced by dinoflagellates, are antagonists of nAChRs. In this study we describe the development and validation of a competitive colorimetric, high throughput functional assay based on the mechanism of action of freshwater and marine toxins against nAChRs. Torpedo electrocyte membranes (rich in muscle-type nAChR) were immobilized and stabilized on the surface of 96-well microtiter plates. Biotinylated α-bungarotoxin (the tracer) and streptavidin-horseradish peroxidase (the detector) enabled the detection and quantitation of anatoxin-a in surface waters and cyclic imine toxins in shellfish extracts that were obtained from different locations across the US. The method compares favorably to LC/MS/MS and provides accurate results for anatoxin-a and cyclic imine toxins monitoring. Study of common constituents at the concentrations normally found in drinking and environmental waters, as well as the tolerance to pH, salt, solvents, organic and inorganic compounds did not significantly affect toxin detection. The assay allowed the simultaneous analysis of up to 25 samples within 3.5 h and it is well suited for on-site or laboratory monitoring of low levels of toxins in drinking, surface, and ground water as well as in shellfish extracts.

  2. Resazurin Microtiter Assay Plate Testing of Mycobacterium tuberculosis Susceptibilities to Second-Line Drugs: Rapid, Simple, and Inexpensive Method

    PubMed Central

    Martin, Anandi; Camacho, Mirtha; Portaels, Françoise; Palomino, Juan Carlos

    2003-01-01

    The emergence of multidrug-resistant tuberculosis calls for new, rapid drug susceptibility tests. We have tested 150 Mycobacterium tuberculosis isolates against the second-line drugs ethionamide, kanamycin, capreomycin, ofloxacin, and para-aminosalicylic acid by the colorimetric resazurin microtiter assay and the proportion method. By visual reading, MICs were obtained after 8 days. A very good correlation between results by the colorimetric resazurin microtiter assay and the proportion method was obtained. The colorimetric resazurin microtiter assay is inexpensive, rapid, and simple to perform, and implementation of the assay is feasible for low-resource countries. PMID:14576129

  3. Comparison of diploid fibroblast and rabbit kidney tissue cultures and a diploid fibroblast microtiter plate system for the isolation of herpes simplex virus.

    PubMed Central

    Langenberg, A; Zbanyszek, R; Dragavon, J; Ashley, R; Corey, L

    1988-01-01

    We evaluated the relative sensitivities of two cell systems (rabbit kidney [RK] and human diploid fibroblast [DF; human embryonic tonsil]) in standard tube cultures versus DF cells in a 48-well microtiter plate system for the detection of both symptomatic and asymptomatic herpes simplex virus (HSV) infection. At least one system isolated HSV in 111 of 809 specimens (13.7%). HSV was isolated in RK tube cultures from 110 specimens (99%), in DF tube cultures from 91 specimens (82%), and in DF microtiter plates from 95 specimens (86%). The frequency of HSV isolation varied with the anatomic site and the presence or absence of a herpetic lesion. The sensitivities of the three culture systems remained similar whether the specimens were obtained from lesions or whether the specimens were taken to determine if asymptomatic excretion of HSV was present. While RK tube cultures were more sensitive than DF tube cultures, the DF microtiter plate system was as sensitive as DF tube cultures and its use is supported as a cheaper and less labor-intensive method for the detection of HSV. PMID:2846647

  4. A High Throughput, 384-Well, Semi-Automated, Hepatocyte Intrinsic Clearance Assay for Screening New Molecular Entities in Drug Discovery.

    PubMed

    Heinle, Lance; Peterkin, Vincent; de Morais, Sonia M; Jenkins, Gary J; Badagnani, Ilaria

    2015-01-01

    A high throughput, semi-automated clearance screening assay in hepatocytes was developed allowing a scientist to generate data for 96 compounds in one week. The 384-well format assay utilizes a Thermo Multidrop Combi and an optimized LC-MS/MS method. The previously reported LCMS/ MS method reduced the analytical run time by 3-fold, down to 1.2 min injection-to-injection. The Multidrop was able to deliver hepatocytes to 384-well plates with minimal viability loss. Comparison of results from the new 384-well and historical 24-well assays yielded a correlation of 0.95. In addition, results obtained for 25 marketed drugs with various metabolism pathways had a correlation of 0.75 when compared with literature values. Precision was maintained in the new format as 8 compounds tested in ≥39 independent experiments had coefficients of variation ≤21%. The ability to predict in vivo clearances using the new stability assay format was also investigated using 22 marketed drugs and 26 AbbVie compounds. Correction of intrinsic clearance values with binding to hepatocytes (in vitro data) and plasma (in vivo data) resulted in a higher in vitro to in vivo correlation when comparing 22 marketed compounds in human (0.80 vs 0.35) and 26 AbbVie Discovery compounds in rat (0.56 vs 0.17), demonstrating the importance of correcting for binding in clearance studies. This newly developed high throughput, semi-automated clearance assay allows for rapid screening of Discovery compounds to enable Structure Activity Relationship (SAR) analysis based on high quality hepatocyte stability data in sufficient quantity and quality to drive the next round of compound synthesis.

  5. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors.

  6. Establishment of a fully automated microtiter plate-based system for suspension cell culture and its application for enhanced process optimization.

    PubMed

    Markert, Sven; Joeris, Klaus

    2017-01-01

    We developed an automated microtiter plate (MTP)-based system for suspension cell culture to meet the increased demands for miniaturized high throughput applications in biopharmaceutical process development. The generic system is based on off-the-shelf commercial laboratory automation equipment and is able to utilize MTPs of different configurations (6-24 wells per plate) in orbital shaken mode. The shaking conditions were optimized by Computational Fluid Dynamics simulations. The fully automated system handles plate transport, seeding and feeding of cells, daily sampling, and preparation of analytical assays. The integration of all required analytical instrumentation into the system enables a hands-off operation which prevents bottlenecks in sample processing. The modular set-up makes the system flexible and adaptable for a continuous extension of analytical parameters and add-on components. The system proved suitable as screening tool for process development by verifying the comparability of results for the MTP-based system and bioreactors regarding profiles of viable cell density, lactate, and product concentration of CHO cell lines. These studies confirmed that 6 well MTPs as well as 24 deepwell MTPs were predictive for a scale up to a 1000 L stirred tank reactor (scale factor 1:200,000). Applying the established cell culture system for automated media blend screening in late stage development, a 22% increase in product yield was achieved in comparison to the reference process. The predicted product increase was subsequently confirmed in 2 L bioreactors. Thus, we demonstrated the feasibility of the automated MTP-based cell culture system for enhanced screening and optimization applications in process development and identified further application areas such as process robustness. The system offers a great potential to accelerate time-to-market for new biopharmaceuticals. Biotechnol. Bioeng. 2017;114: 113-121. © 2016 Wiley Periodicals, Inc.

  7. Prevention of Staphylococcus aureus biofilm formation by antibiotics in 96-Microtiter Well Plates and Drip Flow Reactors: critical factors influencing outcomes

    PubMed Central

    Manner, Suvi; Goeres, Darla M.; Skogman, Malena; Vuorela, Pia; Fallarero, Adyary

    2017-01-01

    Biofilm formation leads to the failure of antimicrobial therapy. Thus, biofilm prevention is a desirable goal of antimicrobial research. In this study, the efficacy of antibiotics (doxycycline, oxacillin and rifampicin) in preventing Staphylococcus aureus biofilms was investigated using Microtiter Well Plates (MWP) and Drip Flow Reactors (DFR), two models characterized by the absence and the presence of a continuous flow of nutrients, respectively. Planktonic culture of S. aureus was exposed to antibiotics for one hour followed by 24 hours incubation with fresh nutrients in MWP or continuous flow of nutrients in DFR. The DFR grown biofilms were significantly more tolerant to the antibiotics than those grown in MWP without the continuous flow. The differences in log reductions (LR) between the two models could not be attributed to differences in the cell density, the planktonic inoculum concentration or the surface-area-to-volume ratios. However, eliminating the flow in the DFR significantly restored the antibiotic susceptibility. These findings demonstrate the importance of considering differences between experimental conditions in different model systems, particularly the flow of nutrients, when performing anti-biofilm efficacy evaluations. Biofilm antibiotic efficacy studies should be assessed using various models and more importantly, in a model mimicking conditions of its clinical application. PMID:28252025

  8. High-throughput system for screening of high L-lactic acid-productivity strains in deep-well microtiter plates.

    PubMed

    Lv, Xiangyun; Song, Jiali; Yu, Bo; Liu, Huilan; Li, Chao; Zhuang, Yingping; Wang, Yonghong

    2016-11-01

    For strain improvement, robust and scalable high-throughput cultivation systems as well as simple and rapid high-throughput detection methods are crucial. However, most of the screening methods for lactic acid bacteria (LAB) strains were conducted in shake flasks and detected by high-performance liquid chromatography (HPLC), making the screening program laborious, time-consuming and costly. In this study, an integrated strategy for high-throughput screening of high L-lactic acid-productivity strains by Bacillus coagulans in deep-well microtiter plates (MTPs) was developed. The good agreement of fermentation results obtained in the MTPs platform with shake flasks confirmed that 24-well U-bottom MTPs could well alternate shake flasks for cell cultivation as a scale-down tool. The high-throughput pH indicator (bromocresol green) and L-lactate oxidase (LOD) assays were subsequently developed to qualitatively and quantitatively analyze L-lactic acid concentration. Together with the color halos method, the pH indicator assay and LOD assay, the newly developed three-step screening strategy has greatly accelerated the screening process for LAB strains with low cost. As a result, two high L-lactic acid-productivity mutants, IH6 and IIIB5, were successfully screened out, which presented, respectively, 42.75 and 46.10 % higher productivities than that of the parent strain in a 5-L bioreactor.

  9. An enzyme-amplified microtiter plate assay for ethanol: Its application to the detection of peanut ethanol and alcohol dehydrogenase

    SciTech Connect

    Chung, S.Y.; Vercellotti, J.R.; Sanders, T.H.

    1995-12-01

    A calorimetric microliter plate assay for ethanol amplified by aldehyde dehydrogenase (ALDH) was developed. In the assay ethanol from a sample took part in a chain-reaction catalyzed by alcohol dehydrogenase (ADH) and amplified by ALDH in the presence of NAD{sup +}, diaphorase, and p-ibdonitrotetrazolium-violet (INT-violet)(a precursor of red product). The resultant reaction gave a red color, the intensity of which was proportional to the amount of ethanol present. Using the technique, the content of activity from peanuts of differing maturity and curing stages were determined respectively. Data showed that immature peanuts had a higher level of ethanol and a lower ADH activity than mature peanuts, and that the level of ethanol and ADH activity decreased with the curing time. This indicates that peanut maturity and curing have an effect on ethanol. Also, this implies that other peanut volatiles could be affected in the same way as ethanol, a major volatile in peanuts.

  10. Oxygen transfer phenomena in 48-well microtiter plates: determination by optical monitoring of sulfite oxidation and verification by real-time measurement during microbial growth.

    PubMed

    Kensy, Frank; Zimmermann, Hartmut F; Knabben, Ingo; Anderlei, Tibor; Trauthwein, Harald; Dingerdissen, Uwe; Büchs, Jochen

    2005-03-20

    Oxygen limitation is one of the most frequent problems associated with the application of shaking bioreactors. The gas-liquid oxygen transfer properties of shaken 48-well microtiter plates (MTPs) were analyzed at different filling volumes, shaking diameters, and shaking frequencies. On the one hand, an optical method based on sulfite oxidation was used as a chemical model system to determine the maximum oxygen transfer capacity (OTR(max)). On the other hand, the Respiration Activity Monitoring System (RAMOS) was applied for online measurement of the oxygen transfer rate (OTR) during growth of the methylotropic yeast Hansenula polymorpha. A proportionality constant between the OTR(max) of the biological system and the OTR(max) of the chemical system were indicated from these data, offering the possibility to transform the whole set of chemical data to biologically relevant conditions. The results exposed "out of phase" shaking conditions at a shaking diameter of 1 mm, which were confirmed by theoretical consideration with the phase number (Ph). At larger shaking diameters (2-50 mm) the oxygen transfer rate in MTPs shaken at high frequencies reached values of up to 0.28 mol/L/h, corresponding to a volumetric mass transfer coefficient (k(L)a) of 1,600 1/h. The specific mass transfer area (a) increases exponentially with the shaking frequency up to values of 2,400 1/m. On the contrary, the mass transfer coefficient (k(L)) is constant at a level of about 0.15 m/h over a wide range of shaking frequencies and shaking diameters. However, at high shaking frequencies, when the complete liquid volume forms a thin film on the cylindric wall of the well, the mass transfer coefficient (k(L)) increases linearly to values of up to 0.76 m/h. Essentially, the present investigation demonstrates that the 48-well plate outperforms the 96-well MTP and shake flasks at widely used operating conditions with respect to oxygen supply. The 48-well plates emerge, therefore, as an excellent

  11. Kinetic Tetrazolium Microtiter Assay

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Stowe, Raymond; Koenig, David

    1993-01-01

    Kinetic tetrazolium microtiter assay (KTMA) involves use of tetrazolium salts and Triton X-100 (or equivalent), nontoxic, in vitro color developer solubilizing colored metabolite formazan without injuring or killing metabolizing cells. Provides for continuous measurement of metabolism and makes possible to determine rate of action of antimicrobial agent in real time as well as determines effective inhibitory concentrations. Used to monitor growth after addition of stimulatory compounds. Provides for kinetic determination of efficacy of biocide, greatly increasing reliability and precision of results. Also used to determine relative effectiveness of antimicrobial agent as function of time. Capability of generating results on day of test extremely important in treatment of water and waste, disinfection of hospital rooms, and in pharmaceutical, agricultural, and food-processing industries. Assay also used in many aspects of cell biology.

  12. Development and Optimization of a Novel 384-Well Anti-Malarial Imaging Assay Validated for High-Throughput Screening

    PubMed Central

    Duffy, Sandra; Avery, Vicky M.

    2012-01-01

    With the increasing occurrence of drug resistance in the malaria parasite, Plasmodium falciparum, there is a great need for new and novel anti-malarial drugs. We have developed a 384-well, high-throughput imaging assay for the detection of new anti-malarial compounds, which was initially validated by screening a marine natural product library, and subsequently used to screen more than 3 million data points from a variety of compound sources. Founded on another fluorescence-based P. falciparum growth inhibition assay, the DNA-intercalating dye 4′,6-diamidino-2-phenylindole, was used to monitor changes in parasite number. Fluorescent images were acquired on the PerkinElmer Opera High Throughput confocal imaging system and analyzed with a spot detection algorithm using the Acapella data processing software. Further optimization of this assay sought to increase throughput, assay stability, and compatibility with our high-throughput screening equipment platforms. The assay typically yielded Z'-factor values of 0.5–0.6, with signal-to-noise ratios of 12. PMID:22232455

  13. Biphasic microtiter method for campylobacter recovery and enumeration

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We developed a biphasic method for recovery and enumeration of campylobacters. The biphasic system was composed of 96-well microtiter plates containing Campy-Line Agar (CLA) prepared 2X for all ingredients except for 1X agar (0.1 ml per well). Samples of pure Campylobacter spp. isolates, post-chi...

  14. Parallel microwave chemistry in silicon carbide microtiter platforms: a review.

    PubMed

    Kappe, C Oliver; Damm, Markus

    2012-02-01

    In this review, applications of silicon carbide-based microtiter platforms designed for use in combination with dedicated multimode microwave reactors are described. These platforms are employed not only for the efficient parallel synthesis of compound libraries, but also in the context of high-throughput reaction screening/optimization and a number of other (bio)analytical and biomedical applications. Since the semiconducting plate material (silicon carbide) is strongly microwave absorbing and possesses high thermal conductivity, no temperature gradients across the microtiter plate exist. Therefore, many of the disadvantages experienced in attempting to perform microtiter plate chemistry under conventional microwave conditions can be eliminated. In general, the silicon carbide-based microtiter platforms allow sealed vessel processing (either directly in the well or in glass vials placed into the wells) of volumes ranging from 0.02-3.0 mL at a maximum temperature/pressure limit of 200°C/20 bar. Depending on the specific plate and rotor configuration, a maximum of 80-192 transformations can be carried out in parallel in a single microwave irradiation experiment under strict temperature control. A platform type utilizing HPLC/GC vials as reaction vessels allows analysis directly from the reaction vessel eliminating the need for a transfer step from the reaction to the analysis vial. The latter system is particularly useful for analytical applications as well as reaction optimization/screening.

  15. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    PubMed Central

    Mohan, Anju; Saxena, Hari Mohan; Malhotra, Puneet

    2016-01-01

    Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT), microtiter plate agglutination test (MAT), indirect hemagglutination assay (IHA), and indirect enzyme-linked immunosorbent assay (iELISA) as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001). The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005). The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002). However, the difference in mean iELISA titers of infected cattle (1.3678±0.014) and healthy vaccinated cattle (1.367±0.014) was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. PMID:27536032

  16. Miniaturization of mitotic index cell-based assay using "wall-less" plate technology.

    PubMed

    Le Guezennec, Xavier; Phong, Mark; Nor, Liyana; Kim, Namyong

    2014-03-01

    The use of microscopic imaging for the accurate assessment of cells in mitosis is hampered by the round morphology of mitotic cells, which renders them poorly adherent and highly susceptible to loss during the washing stage of cell-based assays. Here, to circumvent these limitations, we make use of DropArray, a recent technology that allows high retention of weakly adherent cells and suspension cells. DropArray offers the competitive advantage of maintaining the classic high throughput format of microtiter plates while reducing classic microwell volume by up to 90% by using a drop format. Here, we present a mitotic index cell-based assay using the mitosis marker phospho histone H3 at serine 10 on a DropArray 384-well plate format. Dose-response curve analysis of the mitotic index assay with an antimitotic drug (docetaxel) on DropArray is presented that shows an effective dosage compared to previous established results similar to those obtained with conventional microtiter plates. The mitotic index assay with DropArray showed a Z-factor >0.6. Our results validate DropArray as a suitable platform for high throughput screening for compounds affecting mitosis or the cell cycle.

  17. Influence of affinity on antibody determination in microtiter ELISA systems

    SciTech Connect

    Peterman, J.H.; Voss, E.W. Jr.; Butler, J.E.

    1986-03-01

    Theoretically, all immunoassays are affinity (Ka) dependent when the product of the antibody (Ab) Ka and the free epitope concentration is less than 10. Thus, the degree of dependence on Ka depends on the concentration of available antigen in the system. The authors examined the binding of /sup 125/I-anti-fluorescein (a-FLU) monoclonal antibodies of different affinities to FLU-gelatin adsorbed on Immunlon 2 microtiter plates. Data obtained were in general agreement with our theoretical predictions; the percent of /sup 125/I-a-FLU which bound correlated with Ka, as did the shape of the titration curves. Measurement of 5 a-FLU monoclonals by the ELISA showed that the determination of Ab concentrations depends on the FLU-gelatin concentration, epitope density, and on the relationship between the Kas of test samples and the reference standard Ab preparation. Thus the ELISA is Ka dependent and should not be used routinely to estimate the absolute amount to Ab in unknown samples. However, the Ka dependency of the ELISA might provide a convenient assay for the estimation of the relative functional Ka (rfKa) of antibody preparations.

  18. Microtiter micromass cultures of limb-bud mesenchymal cells.

    PubMed

    Paulsen, D F; Solursh, M

    1988-02-01

    A method is described for growing high-density micromass cultures of chick and mouse limb mesenchyme cells in 96-well microtiter plates (microT microM cultures). Rapid quantitative estimates of chondrogenic expression were obtained by automated spectrophotometric analysis of Alcian-blue-stained cartilage matrix extracts performed in the wells in which the cells had been grown. Quantitative estimates of myogenic expression were obtained similarly using anti-sarcomere myosin monoclonal antibody and modified ELISA techniques. This microT microM-ELISA method may be adapted for use with other antigens for which specific antibodies are available. These methods were used to compare cartilage and muscle differentiation in 1 to 4 d microT microM cultures grown in serum-containing (SCM) and defined (DM) media. The DM contains minimal additives (insulin, hydrocortisone, and in some cases, ascorbate or transferrin) and supports both chondrogenesis and myogenesis. The colorimetric analyses agree well with the morphologic appraisal of chondrogenesis and myogenesis. Similar numbers of cartilage nodules formed in all cultures, but in DM the nodules failed to enlarge; explaining the reduced matrix synthesis in DM as compared with SCM, and suggesting that nodule enlargement is a discrete, serum-dependent step. Studies of selected additives to DM show that transferrin enhances myogenesis, ascorbic acid enhances chondrogenesis, and retinoic acid inhibits chondrogenesis. Together, the microT microM system, in situ colorimetric assays of chondrogenesis and myogenesis, and DM will allow rapid prescreening of teratogens and screening of various bioactive compounds (e.g., hormones, growth factors, vitamins, adhesion factors) for effects on limb mesenchymal cell differentiation.

  19. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  20. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  1. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  2. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  3. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  4. Image-Based 384-Well High-Throughput Screening Method for the Discovery of Skyllamycins A to C as Biofilm Inhibitors and Inducers of Biofilm Detachment in Pseudomonas aeruginosa

    PubMed Central

    Navarro, Gabriel; Cheng, Andrew T.; Peach, Kelly C.; Bray, Walter M.; Bernan, Valerie S.; Yildiz, Fitnat H.

    2014-01-01

    To date, most antibiotics have primarily been developed to target bacteria in the planktonic state. However, biofilm formation allows bacteria to develop tolerance to antibiotics and provides a mechanism to evade innate immune systems. Therefore, there is a significant need to identify small molecules to prevent biofilm formation and, more importantly, to disperse or eradicate preattached biofilms, which are a major source of bacterial persistence in nosocomial infections. We now present a modular high-throughput 384-well image-based screening platform to identify Pseudomonas aeruginosa biofilm inhibitors and dispersal agents. Biofilm coverage measurements were accomplished using non-z-stack epifluorescence microscopy to image a constitutively expressing green fluorescent protein (GFP)-tagged strain of P. aeruginosa and quantified using an automated image analysis script. Using the redox-sensitive dye XTT, bacterial cellular metabolic activity was measured in conjunction with biofilm coverage to differentiate between classical antibiotics and nonantibiotic biofilm inhibitors/dispersers. By measuring biofilm coverage and cellular activity, this screen identifies compounds that eradicate biofilms through mechanisms that are disparate from traditional antibiotic-mediated biofilm clearance. Screening of 312 natural-product prefractions identified the cyclic depsipeptide natural products skyllamycins B and C as nonantibiotic biofilm inhibitors with 50% effective concentrations (EC50s) of 30 and 60 μM, respectively. Codosing experiments of skyllamycin B and azithromycin, an antibiotic unable to clear preattached biofilms, demonstrated that, in combination, these compounds were able to eliminate surface-associated biofilms and depress cellular metabolic activity. The skyllamycins represent the first known class of cyclic depsipeptide biofilm inhibitors/dispersers. PMID:24295976

  5. Image-based 384-well high-throughput screening method for the discovery of skyllamycins A to C as biofilm inhibitors and inducers of biofilm detachment in Pseudomonas aeruginosa.

    PubMed

    Navarro, Gabriel; Cheng, Andrew T; Peach, Kelly C; Bray, Walter M; Bernan, Valerie S; Yildiz, Fitnat H; Linington, Roger G

    2014-01-01

    To date, most antibiotics have primarily been developed to target bacteria in the planktonic state. However, biofilm formation allows bacteria to develop tolerance to antibiotics and provides a mechanism to evade innate immune systems. Therefore, there is a significant need to identify small molecules to prevent biofilm formation and, more importantly, to disperse or eradicate preattached biofilms, which are a major source of bacterial persistence in nosocomial infections. We now present a modular high-throughput 384-well image-based screening platform to identify Pseudomonas aeruginosa biofilm inhibitors and dispersal agents. Biofilm coverage measurements were accomplished using non-z-stack epifluorescence microscopy to image a constitutively expressing green fluorescent protein (GFP)-tagged strain of P. aeruginosa and quantified using an automated image analysis script. Using the redox-sensitive dye XTT, bacterial cellular metabolic activity was measured in conjunction with biofilm coverage to differentiate between classical antibiotics and nonantibiotic biofilm inhibitors/dispersers. By measuring biofilm coverage and cellular activity, this screen identifies compounds that eradicate biofilms through mechanisms that are disparate from traditional antibiotic-mediated biofilm clearance. Screening of 312 natural-product prefractions identified the cyclic depsipeptide natural products skyllamycins B and C as nonantibiotic biofilm inhibitors with 50% effective concentrations (EC50s) of 30 and 60 μM, respectively. Codosing experiments of skyllamycin B and azithromycin, an antibiotic unable to clear preattached biofilms, demonstrated that, in combination, these compounds were able to eliminate surface-associated biofilms and depress cellular metabolic activity. The skyllamycins represent the first known class of cyclic depsipeptide biofilm inhibitors/dispersers.

  6. Community-level physiological profiling performed with an oxygen-sensitive fluorophore in a microtiter plate

    NASA Technical Reports Server (NTRS)

    Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.

    2003-01-01

    Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.

  7. Community-Level Physiological Profiling Performed with an Oxygen-Sensitive Fluorophore in a Microtiter Plate

    PubMed Central

    Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.

    2003-01-01

    Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells. PMID:12732576

  8. Folate content in fresh-cut vegetable packed products by 96-well microtiter plate microbiological assay.

    PubMed

    Fajardo, Violeta; Alonso-Aperte, Elena; Varela-Moreiras, Gregorio

    2015-02-15

    Ready-to-eat foods have nowadays become a significant portion of the diet. Accordingly, nutritional composition of these food categories should be well-known, in particular its folate content. However, there is a broad lack of folate data in food composition tables and databases. A total of 21 fresh-cut vegetable and fruit packed products were analysed for total folate (TF) content using a validated method that relies on the folate-dependent growth of chloramphenicol-resistant Lactobacillus casei subspecies rhamnosus (NCIMB 10463). Mean TF content ranged from 10.0 to 140.9μg/100g for the different matrices on a fresh weight basis. Higher TF quantity, 140.9-70.1μg/100g, was found in spinach, rocket, watercress, chard and broccoli. Significant differences were observed between available data for fresh vegetables and fruits from food composition tables or databases and the analysed results for fresh-cut packed products. Supplied data support the potential of folate-rich fresh-cut ready-to-eat vegetables to increase folate intake significantly.

  9. A Cell-Free Microtiter Plate Screen for Improved [FeFe] Hydrogenases

    PubMed Central

    Stapleton, James A.; Swartz, James R.

    2010-01-01

    Background [FeFe] hydrogenase enzymes catalyze the production and dissociation of H2, a potential renewable fuel. Attempts to exploit these catalysts in engineered systems have been hindered by the biotechnologically inconvenient properties of the natural enzymes, including their extreme oxygen sensitivity. Directed evolution has been used to improve the characteristics of a range of natural catalysts, but has been largely unsuccessful for [FeFe] hydrogenases because of a lack of convenient screening platforms. Methodology/Principal Findings Here we describe an in vitro screening technology for oxygen-tolerant and highly active [FeFe] hydrogenases. Despite the complexity of the protocol, we demonstrate a level of reproducibility that allows moderately improved mutants to be isolated. We have used the platform to identify a mutant of the Chlamydomonas reinhardtii [FeFe] hydrogenase HydA1 with a specific activity ∼4 times that of the wild-type enzyme. Conclusions/Significance Our results demonstrate the feasibility of using the screen presented here for large-scale efforts to identify improved biocatalysts for energy applications. The system is based on our ability to activate these complex enzymes in E. coli cell extracts, which allows unhindered access to the protein maturation and assay environment. PMID:20479937

  10. Microtiter solid-phase radioimmunoassay for detection of human calicivirus in stools.

    PubMed Central

    Nakata, S; Chiba, S; Terashima, H; Sakuma, Y; Kogasaka, R; Nakao, T

    1983-01-01

    A microtiter solid-phase radioimmunoassay (RIA) was developed for detection of human calicivirus in stool specimens. Seventy-eight stool specimens were tested by RIA. All 17 specimens positive for human calicivirus by electron microscopy (EM) were also positive by RIA. In addition, of 21 specimens obtained from an outbreak of caliciviral gastroenteritis, 11 were positive by RIA but negative by EM. Of 20 specimens positive for rotavirus by EM and 20 nondiarrheic specimens with no virus, 2 and 1, respectively, were positive by RIA but were subsequently shown to be falsely positive by a blocking test. There was no cross-reaction between human and feline caliciviruses. Thus, the test was more sensitive than EM and, with an appropriate blocking test, was specific for human calicivirus. It might be especially useful for screening large numbers of stool specimens. PMID:6833476

  11. Acute effects of ethanol or d-amphetamine on the locomotor activity of larval zebrafish in a microtiter plate format.

    EPA Science Inventory

    As part of an effort to develop a rapid in vivo screen for EPA’s prioritization of toxic chemicals, we have begun to characterize the locomotor activity of zebrafish (Danio rerio) larvae. We are assessing the acute effects of prototypic drugs that are known to act on the central ...

  12. Epstein-Barr virus viral capsid antigen titer by immunofluorescence with microplates: new semiautomated method based on the microtiter system.

    PubMed Central

    Lamy, M E; Favart, A M; Burtonboy, G; Arana, A

    1977-01-01

    A semiautomated method of an indirect immunofluorescence technique for the titration of antibodies directed against viral capsid antigens of Epstein-Barr virus has been developed with Microtiter system units. By this method, a technician is able to titrate some hundred samples daily. The technique is safe, easy, and reproducible. The various procedures are described, and the sensitivity of the test is discussed. Images PMID:195981

  13. Development of the nanotiter plate for use in antibody and cell array technologies

    NASA Astrophysics Data System (ADS)

    Ramdutt, Devin; Lui, Rodney; Davies, Kerrie; Boswell, Rod W.; dos Remedios, Cristobal G.; Charles, Christine; Bilek, Marcela M.; McKenzie, David R.

    2005-02-01

    The design and fabrication of biomedical tools using techniques common in microelectronics is becoming established procedure. In our research, we use gaseous plasma dry etching to form microstructures on silicon wafers. These are intended for use in capturing and binding antibodies and live cells in an array to be used in High Throughput Screening (HTS) and High Content Screening (HCS) of new pharmaceuticals. We call this new arraying plate the "Nanotiter" plate. The benefit of our design (100 x 100 wells in a 25 x 25 mm array) over current 96-, 384- and 1056-well microtiter plates are that the number of samples (wells) that can be tested in one plate scan can be substantially increased, the wells can be rapidly and effectively washed, and the well surfaces can be modified to modulate ligand binding. Simple crowding of wells on a plate can result in cross contamination of samples in adjacent wells during the washing. Furthermore, motile cells may migrate between the wells. 1056 microtiter plates currently cannot be washed, and washing 384 plates is problematic. Our design incorporates plasma-deposited polymers that functionally bind antibodies (or other proteins) in but not between wells. Furthermore, the wells can be shaped to minimize cell migration. Inverting the plate on a wash solution allows unbound cells to simply fall away under gravity thus minimising the contamination of adjacent wells. Thus, our Nanotiter plate represents a substantial improvement over existing technology.

  14. Fluorescence lifetime plate reader: resolution and precision meet high-throughput.

    PubMed

    Petersen, Karl J; Peterson, Kurt C; Muretta, Joseph M; Higgins, Sutton E; Gillispie, Gregory D; Thomas, David D

    2014-11-01

    We describe a nanosecond time-resolved fluorescence spectrometer that acquires fluorescence decay waveforms from each well of a 384-well microplate in 3 min with signal-to-noise exceeding 400 using direct waveform recording. The instrument combines high-energy pulsed laser sources (5-10 kHz repetition rate) with a photomultiplier and high-speed digitizer (1 GHz) to record a fluorescence decay waveform after each pulse. Waveforms acquired from rhodamine or 5-((2-aminoethyl)amino) naphthalene-1-sulfonic acid dyes in a 384-well plate gave lifetime measurements 5- to 25-fold more precise than the simultaneous intensity measurements. Lifetimes as short as 0.04 ns were acquired by interleaving with an effective sample rate of 5 GHz. Lifetime measurements resolved mixtures of single-exponential dyes with better than 1% accuracy. The fluorescence lifetime plate reader enables multiple-well fluorescence lifetime measurements with an acquisition time of 0.5 s per well, suitable for high-throughput fluorescence lifetime screening applications.

  15. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  16. Discovery of inhibitors of Shiga toxin type 2 by on-plate generation and screening of a focused compound library.

    PubMed

    Dasgupta, Somnath; Kitov, Pavel I; Sadowska, Joanna M; Bundle, David R

    2014-02-03

    A new microtiter-plate-based method for the rapid generation and evaluation of focused compound libraries was developed and applied to screening ligand analogues for the E. coli Shiga-like toxin Stx2a. The method is general, it mitigates the masking of intrinsic affinity gains by multivalency and enables the discovery of potential hits when starting from ligands that exhibit extremely low affinity with proteins that depend on multivalency for their function.

  17. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  18. Development of a plate-based optical biosensor fragment screening methodology to identify phosphodiesterase 10A inhibitors.

    PubMed

    Geschwindner, Stefan; Dekker, Niek; Horsefield, Rob; Tigerström, Anna; Johansson, Patrik; Scott, Clay W; Albert, Jeffrey S

    2013-04-25

    We describe the development of a novel fragment screening methodology employing a plate-based optical biosensor system that can operate in a 384-well format. The method is based on the "inhibition in solution assay" (ISA) approach using an immobilized target definition compound (TDC) that has been specifically designed for this purpose by making use of available structural information. We demonstrate that this method is robust and is sufficiently sensitive to detect fragment hits as weak as KD 500 μM when confirmed in a conventional surface plasmon resonance approach. The application of the plate-based screen, the identification of fragment inhibitors of PDE10A, and their structural characterization are all discussed in a forthcoming paper.

  19. In vitro activity of titanocenedichloride versus cisplatin in four ovarian carcinoma cell lines evaluated by a microtiter plate ATP bioluminescence assay.

    PubMed

    Kurbacher, C M; Bruckner, H W; Andreotti, P E; Kurbacher, J A; Sass, G; Krebs, D

    1995-10-01

    Titanocenedichloride (MKT 4) is a novel anticancer drug with a broad spectrum of activity in mammalian tumors. We investigated the anticancer efficacy of MKT 4 versus cisplatin and its chemomodulation by buthionine sulfoximine (BSO) in four different human ovarian carcinoma (OvCA) cell lines derived from both primary (A2780. OTN 14) and recurrent tumors (SKOV-3 and OV-MZ-1b) using an in vitro microplate ATP bioluminescence assay (ATP-TCA). Sensitivity against cisplatin was higher in A2780 and OTN 14 compared with MKT 4, whereas the opposite was found in SKOV-3 and OV-MZ-1b cells. In A2780, SKOV-3 and OV-MZ-1b, the cytotoxicity of both agents could be effectively improved by BSO with supraadditive effects observed for MKT 4 in all three cell lines. In OTN 14, however, BSO treatment failed to increase the cytotoxicity of both cisplatin and MKT 4. These results suggest antineoplastic activity of MKT 4 in cisplatin-sensitive and mainly in cisplatin-resistant OvCA cells which can be significantly modulated by BSO-mediated glutathione depletion. Since antineoplastic activity of both cisplatin and MKT-4 observed in OTN 14 could not be reversed by BSO, other mechanisms of drug resistance different from the glutathione redox cycle are likely to be important for both metal compounds.

  20. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  1. Kinetic tetrazolium microtiter assay

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L. (Inventor); Stowe, Raymond P. (Inventor); Koeing, David W. (Inventor)

    1992-01-01

    A method for conducting an in vitro cell assay using a tetrazolium indicator is disclosed. The indicator includes a nonionic detergent which solubilizes a tetrazolium reduction product in vitro and has low toxicity for the cells. The incubation of test cells in the presence of zolium bromide and octoxynol (TRITON X-100) permits kinetics of the cell metabolism to be determined.

  2. Characterization of antibody binding to cell surface antigens using a plasma membrane-bound plate assay.

    PubMed

    Vater, C A; Reid, K; Bartle, L M; Goldmacher, V S

    1995-01-01

    A procedure has been developed for measuring antibody binding to cell surface antigens using an immobilized plasma membrane fraction. In this method, isolated plasma membranes are dried onto wells of a 96-well microtiter plate and incubated with antibodies that recognize a cell surface protein. Bound antibody is detected indirectly using an enzyme-linked or fluorescently tagged second antibody. Alternatively, the primary antibody itself can be labeled and its binding can be detected directly. The assay is simple and fast and provides several advantages over whole cell binding assays currently in widespread use.

  3. Microfluidic titer plate for stratified 3D cell culture.

    PubMed

    Trietsch, Sebastiaan J; Israëls, Guido D; Joore, Jos; Hankemeier, Thomas; Vulto, Paul

    2013-09-21

    Human tissues and organs are inherently heterogeneous. Their functionality is determined by the interplay between different cell types, their secondary architecture, vascular system and gradients of signaling molecules and metabolites. Here we propose a stratified 3D cell culture platform, in which adjacent lanes of gels and liquids are patterned by phaseguides to capture this tissue heterogeneity. We demonstrate 3D cell culture of HepG2 hepatocytes under continuous perfusion, a rifampicin toxicity assay and co-culture with fibroblasts. 4T1 breast cancer cells are used to demonstrate invasion and aggregation models. The platform is incorporated in a microtiter plate format that renders it fully compatible with automation and high-content screening equipment. The extended functionality, ease of handling and full compatibility to standard equipment is an important step towards adoption of Organ-on-a-Chip technology for screening in an industrial setting.

  4. Plate electronics

    NASA Astrophysics Data System (ADS)

    Carlowicz, Michael

    Using a Cray T3D supercomputer and a simple assumption about the physical character of Earth's mantle, a pair of researchers from the University of California at Berkeley have built a computer model that may help explain why the planet's tectonic plates look the way they do.In creating a three-dimensional numerical simulation of convection in the Earth's interior, UC researchers Hans-Peter Bunge and Mark Richards simplified their model to account for just one major physical effect: that the viscosity of the mantle increases with depth. Reviewing some recent—but not yet widely accepted—seismic data, Bunge and Richards assumed for the sake of the model that the viscosity of the mantle increases by a factor of 30 from the lithosphere to the core-mantle boundary. Relying on that assumption, the pair ran the model for nearly three weeks on a supercomputer at Los Alamos National Laboratory and found that the simulation produced an effect similar to what we see on the surface of Earth. The model produced a surface paralleling the actual width of plates and the geometry of the plate boundaries.

  5. Spectral Unmixing Plate Reader: High-Throughput, High-Precision FRET Assays in Living Cells.

    PubMed

    Schaaf, Tory M; Peterson, Kurt C; Grant, Benjamin D; Thomas, David D; Gillispie, Gregory D

    2017-03-01

    We have developed a microplate reader that records a complete high-quality fluorescence emission spectrum on a well-by-well basis under true high-throughput screening (HTS) conditions. The read time for an entire 384-well plate is less than 3 min. This instrument is particularly well suited for assays based on fluorescence resonance energy transfer (FRET). Intramolecular protein biosensors with genetically encoded green fluorescent protein (GFP) donor and red fluorescent protein (RFP) acceptor tags at positions sensitive to structural changes were stably expressed and studied in living HEK cells. Accurate quantitation of FRET was achieved by decomposing each observed spectrum into a linear combination of four component (basis) spectra (GFP emission, RFP emission, water Raman, and cell autofluorescence). Excitation and detection are both conducted from the top, allowing for thermoelectric control of the sample temperature from below. This spectral unmixing plate reader (SUPR) delivers an unprecedented combination of speed, precision, and accuracy for studying ensemble-averaged FRET in living cells. It complements our previously reported fluorescence lifetime plate reader, which offers the feature of resolving multiple FRET populations within the ensemble. The combination of these two direct waveform-recording technologies greatly enhances the precision and information content for HTS in drug discovery.

  6. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  7. Growth Plate Fractures

    MedlinePlus

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for injury. But because they ... to a unique injury called a growth plate fracture. Growth plates are areas of cartilage located near ...

  8. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  9. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  10. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  11. Obliquity along plate boundaries

    NASA Astrophysics Data System (ADS)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  12. Plating Tank Control Software

    SciTech Connect

    Krafcik, John

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  13. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  14. Malachite green photosensitive plates.

    PubMed

    Solano, C

    1989-08-15

    An experimental study of the behavior of malachite green sensitized plates was carried out. The transmittance variation of the irradiated plates was taken as a parameter. It has been observed that photoreduction in the malachite green plates is present only when ammonium dichromate is added to the plates. The introduction of external electron donors does not improve the photochemical reaction. It has been determined that malachite green molecules form a weak complex with the dichromate molecules and this complex can only be destroyed photochemically. This effect can explain the limited response of the malachite green dichromated plates.

  15. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  16. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  17. Confocal-based method for quantification of diffusion kinetics in microwell plates and its application for identifying a rapid mixing method for high-content/throughput screening.

    PubMed

    Song, Ok Ryul; Kim, Tae-Hee; Perrodon, Xavier; Lee, Changbok; Jeon, Hee Kyoung; Seghiri, Zahir; Kwon, Ho Jeong; Cechetto, Jonathan; Christophe, Thierry

    2010-02-01

    Rapid mixing in microplates is still an underappreciated challenge in screening assay development, particularly with the use of noncontact nanoliter liquid handlers. In high-content/throughput screening (HC/TS), fast and efficient mixing between compounds and cell culture medium is even more critical as biological kinetics dictates speed of mixing, usually within a few minutes. Moreover, mixing in HC/TS should be gentle enough to avoid any negative disruption in cell layer. Here the authors introduce a method to accurately quantify drop diffusion into a microplate well, independently of buffer, liquid handler, or dispensing protocol. This method was used to determine the effect of various mixing methods on the diffusion of a nanoliter drop of pure DMSO in aqueous buffer in 384-well plates. Rapid plate shaking and additional buffer addition were shown to be the most efficient and effective mixing methods for HC/TS. However, efficient mixing by plate shaking is limited by assay volume. Bulk addition shows fast and efficient mixing, without negative effects on cells. Moreover, this simple, fast, and inexpensive method can be easily adapted on any platform.

  18. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  19. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  20. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  1. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  2. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  3. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  4. Turbine vane plate assembly

    DOEpatents

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  5. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  6. Pixelated neutron image plates

    NASA Astrophysics Data System (ADS)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  7. Designing Assemblies Of Plates

    NASA Technical Reports Server (NTRS)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  8. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  9. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors.

  10. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  11. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  12. What's On Your Plate?

    MedlinePlus

    ... Table of Contents What's On Your Plate? Smart Food Choices for Healthy Aging www.nia.nih.gov/health/ ... calories in" and "calories out," and making good food choices as you age. Shopping Tips See how planning ...

  13. Feynman's wobbling plate

    NASA Astrophysics Data System (ADS)

    Tuleja, Slavomir; Gazovic, Boris; Tomori, Alexander; Hanc, Jozef

    2007-03-01

    In the book Surely You Are Joking, Mr. Feynman! Richard Feynman tells a story of a Cornell cafeteria plate being tossed into the air. As the plate spun, it wobbled. Feynman noticed a relation between the two motions. He solved the motion of the plate by using the Lagrangian approach. This solution didn't satisfy him. He wanted to understand the motion of the plate by analyzing the motion of its individual particles and the forces acting on them. He was successful, but he didn't tell us how he did it. We provide an elementary explanation for the two-to-one ratio of wobble to spin frequencies, based on an analysis of the motion of the particles and the forces acting on them. We also demonstrate the power of numerical simulation and computer animation to provide insight into a physical phenomenon and guidance on how to do the analysis.

  14. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  15. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  16. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  17. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  18. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  19. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  20. Comparison of GD2 Binding Capture ELISA Assays for Anti-GD2-Antibodies Using GD2-Coated Plates and a GD2-Expressing Cell-Based ELISA

    PubMed Central

    Soman, Gopalan; Yang, Xiaoyi; Jiang, Hengguang; Giardina, Steve; Mitra, Gautam

    2011-01-01

    Two assay methods for quantification of the disialoganglioside (GD2)-specific binding activities of anti-GD2 monoclonal antibodies and antibody immunofusion proteins, such as ch14.18 and hu14.18-IL2, were developed. The methods differed in the use of either microtiter plates coated with purified GD2 or plates seeded with GD2-expressing cell lines to bind the anti-GD2 molecules. The bound antibodies were subsequently detected using the reactivity of the antibodies to an HRP-labeled anti-IgG Fc or antibodies recognizing the conjugate IL-2 part of the Hu 14.18IL-2 fusion protein. The bound HRP was detected using reagents such as orthophenylene diamine, 2, 2’-azinobis [3-ethylbenzothiazoline-6-sulfonic acid] or tetramethylbenzidine. The capture ELISA using GD2-coated plates was developed earlier in assay development and used to demonstrate assay specificity and to compare lot-to-lot consistency and stability of ch14.18, and Hu14.18 IL-2 in clinical development. During this study, we found a number of issues related to plate-to-plate variability, GD2 lot variability, and variations due to GD2 storage stability, etc., that frequently lead to assay failure in plates coated with purified GD2. The cell-based ELISA (CbELISA) using the GD2 expressing melanoma cell line, M21/P6, was developed as an alternative to the GD2-coated plate ELISA. The results on the comparability of the capture ELISA on GD2-coated plates and the cell-based assay show that both assays give comparable results. However, the cell-based assay is more consistent and reproducible. Subsequently, the anti-GD2 capture ELISA using the GD2-coated plate was replaced with the CbELISA for product lot release testing and stability assessment. PMID:21893062

  1. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  2. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  3. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  4. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  5. License plate detection algorithm

    NASA Astrophysics Data System (ADS)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  6. Intermittent Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Silver, P. G.; Behn, M. D.

    2006-12-01

    Intermittent Plate Tectonics A basic premise of Earth Science is that plate tectonics has been continuously operating since it began early in Earth's history. Yet, plate-tectonic theory itself, specifically the collisional phase of the Wilson Cycle, constitutes a process that is capable of stopping all plate motion. The plausibility of a plate-tectonic hiatus is most easily illustrated by considering the expected future of the present-day plate-tectonic configuration. Since the opening of the Atlantic at ~200 ma, the area of the Atlantic basin has been growing at the expense of the Pacific. If this trend continues, relative plate motion models predict that in ~350 my, the Pacific Ocean basin will effectively close leading to widespread continent-continent collisions. Since a continent-continent collision represents the termination of subduction locally, the accumulated effect of all collisions is to stop subduction globally. In this scenario, ridges would then stop spreading and young oceanic lithosphere would cool, reaching a steady-state thickness of 100 km in about 80 my, based on the properties of oceanic lithosphere today. This would constitute the stoppage of plate tectonics. The presumption that plate tectonics never stops in the face of continental collisions is equivalent to requiring that subduction flux is approximately constant through time, such that subduction initiation roughly balances subduction termination. Such a balance then raises several questions about the subduction initiation process. When and how does subduction initiate? Is there a detectible relationship between subduction cessation and subduction initiation? We can gain some guidance into these questions by examining the plate motion history over the last 200 my. Subduction initiation has occurred over the last 80 my in three intra- oceanic subduction zones: Aleutians, Marianas-Izu-Bonin and Tonga-Kermadec in the Pacific basin. In these cases, however, subduction initiation would not

  7. Nuclear reactor alignment plate configuration

    SciTech Connect

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  8. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  9. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  10. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  11. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  12. What Are Growth Plate Injuries?

    MedlinePlus

    ... nih.gov November 2014 What Are Growth Plate Injuries? Fast Facts: An Easy-to-Read Series of Publications ... Some inherited disorders 1 What Are Growth Plate Injuries? Fast Facts: An Easy-to-Read Series of Publications ...

  13. Renewable liquid reflecting zone plate

    DOEpatents

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  14. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  15. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  16. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  17. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  18. Mechanisms in Thermal Mechanical Forming of Plates.

    DTIC Science & Technology

    1987-05-01

    specific locations within the plate is discussed, and recommendations for further research are made. Keywords: Metal plates; Ship plates; Material forming; Thermomechanics; Edge effect ; Laser line heating.

  19. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  20. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  1. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  2. Electronic Equipment Cold Plates

    DTIC Science & Technology

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  3. The Plate Overlap Technique.

    DTIC Science & Technology

    1978-07-31

    INTRODUCTION 1 II. NOTATION 2 III. THE GNOMONIC PROJECTION 4 IV . THE PLATE OVERLAP TECHNIQUE 6 A. MOTIVATION 6 B. FORNULATION 9 C. ON STATISTICAL RIGOR 14 D...and new hardware. Since this aim was clearly recognized long ago, wherever possible in earlier documents or software development flexibility was...reader should see 1, 2, and 3. The procedures one should use to update stellar positions are discussed in 4 with applica- tions to the SAOC in 5. Non

  4. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  5. Armor Plate Surface Roughness Measurements

    DTIC Science & Technology

    2005-04-01

    Armor Plate Surface Roughness Measurements by Brian Stanton, William Coburn, and Thomas J. Pizzillo ARL-TR-3498 April 2005... Armor Plate Surface Roughness Measurements Brian Stanton, William Coburn and Thomas J. Pizzillo Sensors and Electron Devices Directorate...October 2004 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Armor Plate Surface Roughness Measurements 5c. PROGRAM ELEMENT NUMBER

  6. Origin of Small Tectonic Plates

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Coltice, N.; Seton, M.; Müller, D.; Tackley, P.

    2015-12-01

    The plate tectonic theory allowed to split the Earth surface into 6 (Le Pichon 1968) to 52 tectonic plates (Bird 2003). These plates are separated into two groups: the first of 7 large plates and the second of numerous smaller plates (Morra et al 2013). Previous studies using the reconstruction of the past 200 My, suggest that the size of large plates is driven by mantle flow. But the tools employed are descriptive (Morra et al 2013, Sornette and Pisarenko 2003), hence ignoring forces and physical principles within the lithosphere and the mantle. The processes at the origin of small plates remain unknown. We developed a new approach to explain the plate sizes. We demonstrate that the physics of convection drives it. We applied plate tectonics theory on 3D spherical convection models generating plate-like motions, which give access to a complete survey of data: velocities, viscosity and heat flow. Our data show that (1) the large plates depend on the dominating scale of the convective flow due to the initiation or the shutdown of subductions; (2) the smaller plates are generated thanks to large variability of regional stresses along subduction zone by slab pull and suction influenced by the geometry of trenches. Our results are consistent with the quick reorganizations of back-arc basins occuring synchronously with the modification of subduction zones geometry around the Pacific plate (Sdrolias et al 2004). Hence, we conclude that (1) the decreasing number of small plates in the plate reconstructions back in time is an artifact induced by their short lifetime, that is why they are artificially ignored; (2) the geometry of past trenches is simplified leading to an underestimation of the length of subduction zones.

  7. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  8. Hypervelocity impact on shielded plates

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1993-01-01

    A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

  9. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  10. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  11. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  12. Earth's Decelerating Tectonic Plates (Invited)

    NASA Astrophysics Data System (ADS)

    Forte, A. M.; Moucha, R.; Rowley, D. B.; Quere, S.; Mitrovica, J. X.; Simmons, N. A.; Grand, S. P.

    2009-12-01

    We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data (Simmons et al., GJI 2009) to explore the impact of time-dependent changes in mantle buoyancy forces on tectonic plate accelerations. This plate-coupled mantle convection model incorporates a viscosity structure that reconciles both glacial isostatic adjustment and global convection-related data sets (Mitrovica & Forte, EPSL 2004) and it successfully reproduces present-day plate velocities, global surface gravity and topography data. This convection model predicts the recent deceleration of several major plates in the Pacific and Indo-Atlantic hemispheres. Independent verification of these predictions is a fundamental test of the plausibility of the buoyancy forces and rheological structure in the convection model. To this end, we consider marine magnetic anomaly and space geodetic constraints on tectonic plate motions to determine a new global map of present-day rates of change of plate velocities. This map shows that several major plates, such as the Pacific, Africa and Nazca plates are presently decelerating and that they contribute to a globally-averaged slowdown in tectonic plate speeds. These joint geologic-geodetic inferences of plate decelerations are consistent with those predicted by our tomography-based convection model.

  13. Simple plate-based, parallel synthesis of disulfide fragments using the CuAAC click reaction.

    PubMed

    Turner, David M; Tom, Christopher T M B; Renslo, Adam R

    2014-12-08

    Disulfide exchange screening is a site-directed approach to fragment-based lead discovery that requires a bespoke library of disulfide-containing fragments. Previously, we described a simple one-pot, two-step synthesis of disulfide fragments from amine- or acid-bearing starting materials. Here, we describe the synthesis of disulfide fragments that bear a 1,4-substituted-1,2,3-triazole linkage between disulfide and molecular diversity element. This work establishes the compatibility of copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) chemistry with a one-pot, two-step reaction sequence that can be readily parallelized. We performed 96 reactions in a single deep-well microtiter plate, employing 48 alkynes and two different azide linker reagents. From this effort, a total of 81 triazole-containing disulfide fragments were obtained in useful isolated yields. Thus, CuAAC chemistry offers an experimentally convenient method to rapidly prepare disulfide fragments that are structurally distinct from fragments accessed via amide, sulfonamide, or isocyanate chemistries.

  14. Maintaining Microclimates during Nanoliter Chemical Dispensations Using Custom-Designed Source Plate Lids.

    PubMed

    Foley, Bryan J; Drozd, Ashley M; Bollard, Mary T; Laspina, Denise; Podobedov, Nikita; Zeniou, Nicholas; Rao, Anjali S; Andi, Babak; Jackimowicz, Rick; Sweet, Robert M; McSweeney, Sean; Soares, Alexei S

    2016-02-01

    A method is described for using custom snap-on lids to protect chemicals in microtiter plates from evaporation and contamination. The lids contain apertures (diameter 1.5, 1.0, or 0.5 mm) through which the chemical building blocks can be transferred. The lid with 0.5 mm apertures was tested using a noncontact acoustic liquid handler; the 1.0 and 1.5 mm lids were tested using two tip-based liquid handlers. All of the lids reduced the rate at which solvents evaporated to room air, and greatly reduced the rate of contamination by water and oxygen from room air. In steady-state measurements, the lids reduced the rate of evaporation of methanol, 1-hexene, and water by 33% to 248%. In cycled experiments, the contamination of aqueous solvent with oxygen was reduced below detectability and the rate at which DMSO engorged atmospheric water was reduced by 81%. Our results demonstrate that the lids preserve the integrity of air-sensitive reagents during the time needed for different types of liquid handlers to perform dispensations. Controlling degradation and evaporation of chemical building blocks exposed to the atmosphere is increasingly useful as the reagent volume is reduced by advances in liquid handling technology, such as acoustic droplet ejection.

  15. Plating on difficult-to-plate metals: what's new

    SciTech Connect

    Wiesner, H.J.

    1980-07-30

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required.

  16. Localised Plate Motion on Venus

    NASA Astrophysics Data System (ADS)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  17. Tectonics of the Easter plate

    NASA Technical Reports Server (NTRS)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  18. Channel plate for DNA sequencing

    DOEpatents

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  19. Dissolution of HFIR control plates

    SciTech Connect

    Posey, J.C.

    1984-03-01

    A process was developed for the dissolution of High Flux Isotope Reactor (HFIR) control plates. These plates consist of aluminum metal, intensely radioactive europium oxide, and a small amount of tantalum metal. The radioactive solution will be diluted, mixed with grout, and disposed of by shale fracture. The plates are dissolved in nitric acid using a mercury catalyst. Conditions were determined that would produce a reaction rate compatible with existing equipment. 3 references, 1 figure, 3 tables.

  20. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  1. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  2. Laser-driven flyer plate

    DOEpatents

    Paisley, Dennis L.

    1991-01-01

    Apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma.

  3. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  4. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  5. Carbon-assisted flyer plates

    DOEpatents

    Stahl, David B.; Paisley, Dennis L.

    1994-01-01

    A laser driven flyer plate utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited.

  6. Scintillator plate calorimetry

    SciTech Connect

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin.

  7. Intermittent plate tectonics?

    PubMed

    Silver, Paul G; Behn, Mark D

    2008-01-04

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  8. 10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: 1889, BUILT BY THE BERLIN IRON BRIDGE CO. EAST BERLIN CONN. DOUGLAS & JARVIS PAT. APT. 16, 1878, AP'L 17, 1885. A.P. FORESMAN, WM. S. STARR, T.J. STREBEIGH, COMMISSIONERS. - Pine Creek Bridge, River Road spanning Pine Creek, Jersey Shore, Lycoming County, PA

  9. Downgoing plate controls on overriding plate deformation in subduction zones

    NASA Astrophysics Data System (ADS)

    Garel, Fanny; Davies, Rhodri; Goes, Saskia; Davies, Huw; Kramer, Stephan; Wilson, Cian

    2014-05-01

    Although subduction zones are convergent margins, deformation in the upper plate can be extensional or compressional and tends to change through time, sometimes in repeated episodes of strong deformation, e.g, phases of back-arc extension. It is not well understood what factors control this upper plate deformation. We use the code Fluidity, which uses an adaptive mesh and a free-surface formulation, to model a two-plate subduction system in 2-D. The model includes a composite temperature- and stress-dependent rheology, and plates are decoupled by a weak layer, which allows for free trench motion. We investigate the evolution of the state of stress and topography of the overriding plate during the different phases of the subduction process: onset of subduction, free-fall sinking in the upper mantle and interaction of the slab with the transition zone, here represented by a viscosity contrast between upper and lower mantle. We focus on (i) how overriding plate deformation varies with subducting plate age; (ii) how spontaneous and episodic back-arc spreading develops for some subduction settings; (iii) the correlation between overriding plate deformation and slab interaction with the transition zone; (iv) whether these trends resemble observations on Earth.

  10. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  11. A Quantitative High-Throughput 96-well plate Fluorescence Assay for Mechanism-Based Inactivators of Cytochromes P450 Exemplified using CYP2B6

    PubMed Central

    Kenaan, Cesar; Zhang, Haoming; Hollenberg, Paul F.

    2010-01-01

    Mechanism-based inactivators such as bergamottin are useful chemical tools for identifying the roles of specific active-site amino acid residues in the reactions catalyzed by the cytochromes P450 (CYPs or P450s) that are responsible for the metabolism of a wide variety of drugs and endogenous substrates. In clinical settings mechanism-based inactivation of P450s involved in xenobiotic metabolism has the potential to lead to adverse drug-drug interactions and assays to identify and characterize drug candidates as P450 inactivators are important in drug discovery and development. Here we present a quantitative high-throughput protocol for investigating cytochrome P450 mechanism-based inactivators using the example of CYP2B6 and bergamottin to illustrate the finer points of this protocol. This protocol details the adaptation of a 7-ethoxytrifluoromethyl coumarin (7-EFC) O-deethylation fluorescence activity assay to a 96-well microtiter plate format and uses a plate-reader to detect the fluorescence of the product. Compared to previous methods, this protocol requires less P450 and takes significantly less time while greatly increasing throughput. The protocol as written takes approximately two hours to complete. The principles and procedures outlined in this protocol can be easily adapted to other inactivators, P450 isoforms, substrates and plate-readers. PMID:20885377

  12. Metals plated on fluorocarbon polymers

    NASA Technical Reports Server (NTRS)

    Ford, H.; Krasinsky, J. B.; Vango, S. P.

    1964-01-01

    Electroplating lead on fluorocarbon polymer parts is accomplished by etching the parts to be plated with sodium, followed by successive depositions of silver and lead from ultrasonically agitated plating solutions. Metals other than lead may be electroplated on the silvered parts.

  13. Metal vapor arc ion plating

    DOEpatents

    Bertram, L.A.; Fisher, R.W.; Mattox, D.M.; Zanner, F.J.

    1986-09-09

    A method and apparatus for ion plating are described. The apparatus uses more negative than a first electrode voltage in a vacuum arc remelt system to attract low energy ions from the anode electrode to the article to be plated. 2 figs.

  14. Gold plating on spectacle frames.

    PubMed

    Kenny, I; Mitchell, J W; Walsh, G

    1997-05-01

    An investigation was carried out into the thickness and standard of application of the plating and lacquer coatings applied to three metal spectacle frames. All conform to BS 6625 (1991) for plating thickness, but there was considerable variation in regularity and porosity.

  15. Micro-channel plate detector

    DOEpatents

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  16. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  17. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  18. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  19. The moving plate capacitor paradox

    NASA Astrophysics Data System (ADS)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2000-03-01

    For the first time we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. A demon restores the plates of the capacitor to their original position, only when the voltage across the capacitor is small—hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the question is how? We explore the concept of a moving plate capacitor, driven by noise, a step further by examining the case where the restoring force on the capacitor plates is provided by a simple spring, rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other.

  20. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  1. Development and Validation of a Quantitative, High-Throughput, Fluorescent-Based Bioassay to Detect Schistosoma Viability

    PubMed Central

    Peak, Emily; Chalmers, Iain W.; Hoffmann, Karl F.

    2010-01-01

    Background Schistosomiasis, caused by infection with the blood fluke Schistosoma, is responsible for greater than 200,000 human deaths per annum. Objective high-throughput screens for detecting novel anti-schistosomal targets will drive ‘genome to drug’ lead translational science at an unprecedented rate. Current methods for detecting schistosome viability rely on qualitative microscopic criteria, which require an understanding of parasite morphology, and most importantly, must be subjectively interpreted. These limitations, in the current state of the art, have significantly impeded progress into whole schistosome screening for next generation chemotherapies. Methodology/Principal Findings We present here a microtiter plate-based method for reproducibly detecting schistosomula viability that takes advantage of the differential uptake of fluorophores (propidium iodide and fluorescein diacetate) by living organisms. We validate this high-throughput system in detecting schistosomula viability using auranofin (a known inhibitor of thioredoxin glutathione reductase), praziquantel and a range of small compounds with previously-described (gambogic acid, sodium salinomycin, ethinyl estradiol, fluoxetidine hydrochloride, miconazole nitrate, chlorpromazine hydrochloride, amphotericin b, niclosamide) or suggested (bepridil, ciclopirox, rescinnamine, flucytosine, vinblastine and carbidopa) anti-schistosomal activities. This developed method is sensitive (200 schistosomula/well can be assayed), relevant to industrial (384-well microtiter plate compatibility) and academic (96-well microtiter plate compatibility) settings, translatable to functional genomics screens and drug assays, does not require a priori knowledge of schistosome biology and is quantitative. Conclusions/Significance The wide-scale application of this fluorescence-based bioassay will greatly accelerate the objective identification of novel therapeutic lead targets/compounds to combat schistosomiasis

  2. Underwater electrical discharge in plate to plate configuration

    NASA Astrophysics Data System (ADS)

    Stelmashuk, Vitaliy

    2016-09-01

    Two main configurations of high voltage electrodes submersed in water have been used for an electrical discharge generation: pin to pin and pin to plate. An electrical breakdown between plate electrodes is generally difficult to reproduce, because there is a uniform and weak electric field. One major advantage of using plate electrodes is their greater ``wear hardness'' to high-energy discharges. The plate electrodes can withstand extremely high energy deposition at which the pin electrode is quickly destroyed. The electrical discharge between plate electrodes can be initiated by creating an inhomogeneity in the electrical field. Two methods of discharge initiation between plate electrodes are proposed for this aim: 1) focusing of a shock wave in the interelectrode region; 2) a bubble injection into the electrode gap. The shock wave creates favourable conditions for the electrical breakdown between the two plate electrodes: it causes that numerous microbubbles of dissolved air start to grow and serve as locations for streamer initiation. In the second method the gas bubble is injected from the one of the electrodes, which has a gas inlet hole on the lateral face for this purpose. A ``volcano'' like morphology of positive streamers are observed in the experiments with weak electric field. The authors are grateful to MEYS grant INGO LG 15013.

  3. Statistical tests of additional plate boundaries from plate motion inversions

    NASA Technical Reports Server (NTRS)

    Stein, S.; Gordon, R. G.

    1984-01-01

    The application of the F-ratio test, a standard statistical technique, to the results of relative plate motion inversions has been investigated. The method tests whether the improvement in fit of the model to the data resulting from the addition of another plate to the model is greater than that expected purely by chance. This approach appears to be useful in determining whether additional plate boundaries are justified. Previous results have been confirmed favoring separate North American and South American plates with a boundary located beween 30 N and the equator. Using Chase's global relative motion data, it is shown that in addition to separate West African and Somalian plates, separate West Indian and Australian plates, with a best-fitting boundary between 70 E and 90 E, can be resolved. These results are generally consistent with the observation that the Indian plate's internal deformation extends somewhat westward of the Ninetyeast Ridge. The relative motion pole is similar to Minster and Jordan's and predicts the NW-SE compression observed in earthquake mechanisms near the Ninetyeast Ridge.

  4. Highly curved microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  5. Balanced Orifice Plate

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Buskirk, Paul D. (Inventor)

    2006-01-01

    An orifice plate for use in a conduit through which fluid flows is defined by a central circular region having a radius R, and a ring-shaped region surrounding the central circular region. The ring-shaped region has holes formed therethrough with those holes centered at each radius R thereof satisfying a relationship A(sub R)=al(X(sub R)V(sub R)(sup b)) where A(sub R) is a sum of areas of those holes having centers at radius R, X(sub R) is a flow coefficient at radius R, V(sub R) is a velocity of the fluid that is to flow through the conduit at radius R, b is a constant selected to make at least one process variable (associated with the fluid that is to flow through the conduit) approximately equal at each radius R, and a is a constant that is equal to (X(sub R)A(sub R)V(sub R)(sup b)) at each radius R.

  6. High loading uranium fuel plate

    DOEpatents

    Wiencek, Thomas C.; Domagala, Robert F.; Thresh, Henry R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  7. Tectonics: Changing of the plates

    NASA Astrophysics Data System (ADS)

    Brandon, Alan

    2016-10-01

    The composition of Earth's crust depends on the style of plate tectonics and of the melting regimes in the mantle. Analyses of the oldest identified rocks suggest that these styles and the resulting crust have changed over Earth's history.

  8. Carbon-assisted flyer plates

    DOEpatents

    Stahl, D.B.; Paisley, D.L.

    1994-04-12

    A laser driven flyer plate is described utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited. 2 figures.

  9. MyPlate Daily Checklist

    MedlinePlus

    ... Kids Making Family Mealtimes Fun Professionals Nutrition Communicators Network Communicator’s Guide Teachers Health Professionals MyPlate Graphics Multiple Languages En Español Other Languages Healthy Eating Style ...

  10. ChooseMyPlate.gov

    MedlinePlus

    ... Kids Making Family Mealtimes Fun Professionals Nutrition Communicators Network Communicator’s Guide Teachers Health Professionals MyPlate Graphics Multiple Languages En Español Other Languages Healthy Eating Style ...

  11. The multigap resistive plate chamber

    SciTech Connect

    Zeballos, E. Cerron; Crotty, I.; Hatzifotiadou, D.; Valverde, J. Lamas; Neupane, S.; Williams, M. C. S.; Zichichi, A.

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  12. Reflection-Zone-Plate Antenna

    NASA Technical Reports Server (NTRS)

    Franke, John M.; Leighty, Bradley D.

    1989-01-01

    Microwave antenna, based on reflection holography, designed and tested. Modified to produce arbitrary beam patterns by controlling relief pattern. Antenna planar or contoured to supporting structure. Low off-axis radar cross section at frequencies removed from operational frequency. Interference pattern produced by spherical wave intersecting plane wave consists of concentric circles similar to Newton's rings. Pattern identical to Fresnel zone plate, which has lens properties. Plane wave incident on hologram, or zone plate, focused to point.

  13. Impact on multilayered composite plates

    NASA Technical Reports Server (NTRS)

    Kim, B. S.; Moon, F. C.

    1977-01-01

    Stress wave propagation in a multilayer composite plate due to impact was examined by means of the anisotropic elasticity theory. The plate was modelled as a number of identical anisotropic layers and the approximate plate theory of Mindlin was then applied to each layer to obtain a set of difference-differential equations of motion. Dispersion relations for harmonic waves and correction factors were found. The governing equations were reduced to difference equations via integral transforms. With given impact boundary conditions these equations were solved for an arbitrary number of layers in the plate and the transient propagation of waves was calculated by means of a Fast Fourier Transform algorithm. The multilayered plate problem was extended to examine the effect of damping layers present between two elastic layers. A reduction of the interlaminar normal stress was significant when the thickness of damping layer was increased but the effect was mostly due to the softness of the damping layer. Finally, the problem of a composite plate with a crack on the interlaminar boundary was formulated.

  14. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-04

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction.

  15. Geometry of the Cocos Plate Under North American Plate

    NASA Astrophysics Data System (ADS)

    Perez-Campos, X.

    2015-12-01

    The Cocos plate subducts under the North American plate with a complex geometry, and previous seismicity studies revealed some of this complexity. However, details of the geometry and the depth that the plate penetrates werelargely unknown. Since 2004, temporary experiments and the expansion of the permanent network of the Servicio Sismológico Nacional (SSN, Mexican National Seismological Service) have improved resolution of the plate geometry and have helped to map its descent into the upper mantle. Going from northwest to southeast, the Cocos plate appears to be fragmenting into north and south segments. The north segment subducts with an angle of ~30º and the south with an angle of ~10-15º. The transition is smooth near the trench and progresses to a tear at depth; this coincides with the projection of the Orozco Fracture Zone to depth. Also, this transition marks the limit of the presence to the south of an ultra slow velocity layer (USL) on top of the slab.South of this transition, the Cocos plate subducts horizontally , underplating the North American plate for a distance of ~140 to ~300 km from the trench. Along this horizontal region, silent slow events (SSE) and tectonic tremor (TT) have been observed. At a distance of 300 km from the trench (beneath central Mexico), the plate dives into the mantle with an angle of 76º to a depth of 500 km. This geometry changes abruptly to the south, marking the eastern limit of the USL. This change seems to be also characterized by a tear on the slab. Finally to the south, the Cocos plate subducts with a constant angle of 26º. This presentation summarizes the work of many contributors including A. Arciniega-Ceballos, M. Brudzinski, E. Cabral-Cano, T. Chen, R. Clayton,F. Cordoba-Montiel,P. Davis,S. Dougherty,F. Green, M. Gurnis, D. V. Helmberger, A. Husker,A. Iglesias, Y. Kim, V. Manea, D. Melgar, M. Rodríguez-Domínguez,S. K. Singh, T.-R. A. Song, C. M. Valdés-González, D. Valencia-Cabrera

  16. Plate mode velocities in graphite/epoxy plates

    NASA Technical Reports Server (NTRS)

    Prosser, W. H.; Gorman, M. R.

    1994-01-01

    Measurements of the velocities of the extensional and flexural plate modes were made along three directions of propagation in four graphite/epoxy composite plates. The acoustic signals were generated by simulated acoustic emission events (pencil lead breaks or Hsu-Neilson sources) and detected by by broadband ultrasonic transducers. The first arrival of the extensional plate mode, which is nondispersive at low frequencies, was measured at a number of different distances from the source along the propagation direction of interest. The velocity was determined by plotting the distance versus arrival time and computing its slope. Because of the large dispersion of the flexural mode, a Fourier phase velocity technique was used to characterize this mode. The velocity was measured up to a frequency of 160 kHz. Theoretical predictions of the velocities of these modes were also made and compared with experimental observations. Classical plate theory yields good agreement with the measured extensional velocities. For predictions of the dispersion of the flexural mode, Mindlin plates theory, which includes the effects of shear deformation and rotatory inertia was shown to give better agreement with the experimental measurements.

  17. [The use of blade plate and dynamic screw plate osteosynthesis].

    PubMed

    Oestern, H J; Gänsslen, A

    2010-02-01

    Osteosynthesis in fracture treatment and in some reconstructive procedures with blade plates or dynamic screw systems was the standard procedure for several decades. In this review, the current options and concepts using blade plate osteosynthesis, stabilization of proximal and distal femur fractures and reconstructive procedures with the dynamic hip screw or the dynamic condylar blade are discussed. On the basis of a literature review, the present indications, results and region-specific complications are reported and discussed.Blade plates are used mainly in the context of reconstructive procedures, as well as in the treatment of pseudoarthroses. The Pauwel procedure in femoral neck non-unions is one of the best known indications. In contrast, the dynamic hip screw is the gold standard for stabilization of femoral neck and most pertrochanteric fractures, whereas the dynamic condylar screw is still an alternative to internal fixators for proximal and distal femoral fracture fixations.

  18. The epiphyseal plate: physiology, anatomy, and trauma.

    PubMed

    von Pfeil, Dirsko J F; DeCamp, Charles E

    2009-08-01

    This article reviews the development of long bones, the microanatomy and physiology of the growth plate, the closure times and contribution of different growth plates to overall growth, and the effect of, and prognosis for, traumatic injuries to the growth plate. Details on surgical treatment of growth plate fractures are beyond the scope of this article.

  19. Plate tectonics of the Mediterranean region.

    PubMed

    McKenzie, D P

    1970-04-18

    The seismicity and fault plane solutions in the Mediterranean area show that two small rapidly moving plates exist in the Eastern Mediterranean, and such plates may be a common feature of contracting ocean basins. The results show that the concepts of plate tectonics apply to instantaneous motions across continental plate boundaries.

  20. Beyond plate tectonics - Looking at plate deformation with space geodesy

    NASA Technical Reports Server (NTRS)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  1. Plating on some difficult-to-plate metals and alloys

    SciTech Connect

    Dini, J.W.; Johnson, H.R.

    1984-02-21

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests. 3 figures, 9 tables.

  2. Plating on some difficult-to-plate metals and alloys

    SciTech Connect

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests.

  3. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  4. Multiple-Dynode-Layer Microchannel Plate

    NASA Technical Reports Server (NTRS)

    Woodgate, Bruce E.

    1990-01-01

    Improved microchannel-plate electron image amplifier made of stack of discrete microchannel-plate layers. New plates easier to manufacture because no need to etch long, narrow holes, to draw and bundle thin glass tubes, or to shear plates to give microchannels curvatures necessary for reduction of undesired emission of ions. Discrete dynode layers stacked with slight offset from layer to layer to form microchannel plate with curved channels. Provides for relatively fast recharging of microchannel dynodes, with consequent enhancement of performance.

  5. Insert metering plates for gas turbine nozzles

    DOEpatents

    Burdgick, Steven S.; Itzel, Gary; Chopra, Sanjay; Abuaf, Nesim; Correia, Victor H.

    2004-05-11

    The invention comprises a metering plate which is assembled to an impingement insert for use in the nozzle of a gas turbine. The metering plate can have one or more metering holes and is used to balance the cooling flow within the nozzle. A metering plate with multiple holes reduces static pressure variations which result from the cooling airflow through the metering plate. The metering plate can be assembled to the insert before or after the insert is inserted into the nozzle.

  6. Riveted joints in thin plates

    NASA Technical Reports Server (NTRS)

    Hilbes, W

    1930-01-01

    The method of riveting by forming the closing head under increasing pressure or by a series of hammer blows is investigated. The question as to the best edge distance, i.e. that distance from the rivet center to the plate edge below which it is unadvisable to go and, at the same time useless to go beyond, was examined. The slippage of plates which occurs under the effect of a certain stress, does not completely disappear on unloading. The elastic form change is essentially a function of the elasticity modulus, the slip modulus, the supporting moment, the rivet spacing, etc.

  7. Titer plate formatted continuous flow thermal reactors for high throughput applications: fabrication and testing

    NASA Astrophysics Data System (ADS)

    Sang-Won Park, Daniel; Chen, Pin-Chuan; You, Byoung Hee; Kim, Namwon; Park, Taehyun; Lee, Tae Yoon; Datta, Proyag; Desta, Yohannes; Soper, Steven A.; Nikitopoulos, Dimitris E.; Murphy, Michael C.

    2010-05-01

    A high throughput, multi-well (96) polymerase chain reaction (PCR) platform, based on a continuous flow (CF) mode of operation, was developed. Each CFPCR device was confined to a footprint of 8 × 8 mm2, matching the footprint of a well on a standard micro-titer plate. While several CFPCR devices have been demonstrated, this is the first example of a high-throughput multi-well continuous flow thermal reactor configuration. Verification of the feasibility of the multi-well CFPCR device was carried out at each stage of development from manufacturing to demonstrating sample amplification. The multi-well CFPCR devices were fabricated by micro-replication in polymers, polycarbonate to accommodate the peak temperatures during thermal cycling in this case, using double-sided hot embossing. One side of the substrate contained the thermal reactors and the opposite side was patterned with structures to enhance thermal isolation of the closely packed constant temperature zones. A 99 bp target from a λ-DNA template was successfully amplified in a prototype multi-well CFPCR device with a total reaction time as low as ~5 min at a flow velocity of 3 mm s-1 (15.3 s cycle-1) and a relatively low amplification efficiency compared to a bench-top thermal cycler for a 20-cycle device; reducing the flow velocity to 1 mm s-1 (46.2 s cycle-1) gave a seven-fold improvement in amplification efficiency. Amplification efficiencies increased at all flow velocities for 25-cycle devices with the same configuration.

  8. License Plate Recognition System for Indian Vehicles

    NASA Astrophysics Data System (ADS)

    Sanap, P. R.; Narote, S. P.

    2010-11-01

    We consider the task of recognition of Indian vehicle number plates (also called license plates or registration plates in other countries). A system for Indian number plate recognition must cope with wide variations in the appearance of the plates. Each state uses its own range of designs with font variations between the designs. Also, vehicle owners may place the plates inside glass covered frames or use plates made of nonstandard materials. These issues compound the complexity of automatic number plate recognition, making existing approaches inadequate. We have developed a system that incorporates a novel combination of image processing and artificial neural network technologies to successfully locate and read Indian vehicle number plates in digital images. Commercial application of the system is envisaged.

  9. Elastic stability of thick auxetic plates

    NASA Astrophysics Data System (ADS)

    Lim, Teik-Cheng

    2014-04-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads.

  10. Effects of a sliding plate on morphology of the epiphyseal plate in goat distal femur.

    PubMed

    Lin, Da-sheng; Lian, Ke-jian; Hong, Jia-yuan; Ding, Zhen-qi; Zhai, Wen-liang

    2012-01-01

    The aim of this study was to observe the effects of a sliding plate on the morphology of the epiphyseal plate in goat distal femur. Eighteen premature female goats were divided randomly into sliding plate, regular plate and control groups. Radiographic analysis and histological staining were performed to evaluate the development of epiphyseal plate at 4 and 8 weeks after surgery. In the sliding plate group, the plate extended accordingly as the epiphyseal plate grows, and the epiphyseal morphology was kept essential normal. However, the phenomenon of the epiphyseal growth retardation and premature closure were very common in the regular plate group. In addition, the sliding plate group exhibited more normal histologic features and Safranin O staining compared to the regular plate group. Our results suggest that the sliding plate can provide reliable internal fixation of epiphyseal fracture without inhibiting epiphyseal growth.

  11. Effects of a Sliding Plate on Morphology of the Epiphyseal Plate in Goat Distal Femur

    PubMed Central

    LIN, Da-sheng; LIAN, Ke-jian; HONG, Jia-yuan; DING, Zhen-qi; ZHAI, Wen-liang

    2012-01-01

    The aim of this study was to observe the effects of a sliding plate on the morphology of the epiphyseal plate in goat distal femur. Eighteen premature female goats were divided randomly into sliding plate, regular plate and control groups. Radiographic analysis and histological staining were performed to evaluate the development of epiphyseal plate at 4 and 8 weeks after surgery. In the sliding plate group, the plate extended accordingly as the epiphyseal plate grows, and the epiphyseal morphology was kept essential normal. However, the phenomenon of the epiphyseal growth retardation and premature closure were very common in the regular plate group. In addition, the sliding plate group exhibited more normal histologic features and Safranin O staining compared to the regular plate group. Our results suggest that the sliding plate can provide reliable internal fixation of epiphyseal fracture without inhibiting epiphyseal growth. PMID:22359485

  12. MyPlate Food Guide

    MedlinePlus

    ... whole-wheat bread, brown rice, or oatmeal. 4. Protein Foods that are high in protein help the body build, maintain, and repair tissue. ... on the MyPlate graphic shows the proportion of protein you need. Foods high in protein include beef, ...

  13. Shaker slip-plate adapter

    NASA Technical Reports Server (NTRS)

    Holm, O. S.

    1969-01-01

    Magnesium adapter ties in all of the attachment bosses on a horizontal slip table and makes a rigid coupling which terminates in a single row of attachment bosses at the edge of the horizontal plate. This eliminates ineffective dissipation of the driving force in vibration tests.

  14. Double-Plate Penetration Equations

    NASA Technical Reports Server (NTRS)

    Hayashida, K. B.; Robinson, J. H.

    2000-01-01

    This report compares seven double-plate penetration predictor equations for accuracy and effectiveness of a shield design. Three of the seven are the Johnson Space Center original, modified, and new Cour-Palais equations. The other four are the Nysmith, Lundeberg-Stern-Bristow, Burch, and Wilkinson equations. These equations, except the Wilkinson equation, were derived from test results, with the velocities ranging up to 8 km/sec. Spreadsheet software calculated the projectile diameters for various velocities for the different equations. The results were plotted on projectile diameter versus velocity graphs for the expected orbital debris impact velocities ranging from 2 to 15 km/sec. The new Cour-Palais double-plate penetration equation was compared to the modified Cour-Palais single-plate penetration equation. Then the predictions from each of the seven double-plate penetration equations were compared to each other for a chosen shield design. Finally, these results from the equations were compared with test results performed at the NASA Marshall Space Flight Center. Because the different equations predict a wide range of projectile diameters at any given velocity, it is very difficult to choose the "right" prediction equation for shield configurations other than those exactly used in the equations' development. Although developed for various materials, the penetration equations alone cannot be relied upon to accurately predict the effectiveness of a shield without using hypervelocity impact tests to verify the design.

  15. Comment on "Intermittent plate tectonics?".

    PubMed

    Korenaga, Jun

    2008-06-06

    Silver and Behn (Reports, 4 January 2008, p. 85) proposed that intermittent plate tectonics may resolve a long-standing paradox in Earth's thermal evolution. However, their analysis misses one important term, which subsequently brings their main conclusion into question. In addition, the Phanerozoic eustasy record indicates that the claimed effect of intermittency is probably weak.

  16. Petroleum occurrences and plate tectonics

    SciTech Connect

    Olenin, V.B.; Sokolov, B.A.

    1983-01-01

    This paper analyzes the mechanisms of petroleum formation and petroleum accumulation proposed in recent years by some Russian and foreign investigators from the viewpoint of the new global or plate tectonics. On the basis of discussion and the facts, the authors conclude that the mechanisms proposed are in contradiction to reality and their use in practical application is at least premature.

  17. Corrosion resistant metallic bipolar plate

    DOEpatents

    Brady, Michael P.; Schneibel, Joachim H.; Pint, Bruce A.; Maziasz, Philip J.

    2007-05-01

    A corrosion resistant, electrically conductive component such as a bipolar plate for a PEM fuel cell includes 20 55% Cr, balance base metal such as Ni, Fe, or Co, the component having thereon a substantially external, continuous layer of chromium nitride.

  18. Plated wire random access memories

    NASA Technical Reports Server (NTRS)

    Gouldin, L. D.

    1975-01-01

    A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.

  19. The seismotectonics of plate boundaries

    NASA Technical Reports Server (NTRS)

    Berger, J.; Brune, J. N.; Goodkind, J.; Wyatt, F.; Agnew, D. C.; Beaumont, C.

    1981-01-01

    Research on the seismotectonics of plate boundaries is summarized. Instrumental development and an observational program designed to study various aspects of the seismotectonics of southern California and the northern Gulf of California are described. A unique superconducting gravimeter was further developed and supported under this program for deployment and operation at several sites. Work on Earth tides is also discussed.

  20. Plating Processes Utilizing High Intensity Acoustic Beams

    NASA Technical Reports Server (NTRS)

    Oeftering, Richard C. (Inventor); Denofrio, Charles (Inventor)

    2002-01-01

    A system and a method for selective plating processes are disclosed which use directed beams of high intensity acoustic waves to create non-linear effects that alter and improve the plating process. The directed beams are focused on the surface of an object, which in one embodiment is immersed in a plating solution, and in another embodiment is suspended above a plating solution. The plating processes provide precise control of the thickness of the layers of the plating, while at the same time, in at least some incidents, eliminates the need for masking.

  1. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  2. Absorbable plate strength loss during molding.

    PubMed

    Ballard, Tiffany N S; Kelly, Kevin J; Zaydfudim, Victor; Walcutt, Noah L; Lahijani, Soheil S; Shack, R Bruce; Thayer, Wesley P

    2010-05-01

    Bioabsorbable plating systems play an integral role in cranial vault remodeling. After experiencing a case of plate failure requiring emergent reexploration, we investigated the potential causes. We hypothesize that extended submersion in the molding bath during plate preparation might advance the rate of hydrolysis and compromise plate structural integrity. Using an absorbable poly-D/L-lactic acid plating system, we assessed the effect of extended submersion on plate strength and stiffness when loaded in a cantilever fashion and with pure tension. We assessed these differences with the Student t test and linear regression modeling. We also generated a computer model of the plates for finite element analysis. When left in the molding bath for extended periods, the plates changed color and lost strength. After 5 minutes, 30% of maximum plate load capacity was lost in a cantilever beam test (P < 0.001) consistent with use of a 15% thinner plate. Tensile testing revealed the initial elastic modulus of 6.42 +/- 0.13 GPa decreased 16% to 5.41 +/- 0.50 GPa after 5 minutes of submersion (P = 0.027). The changes in plate strength and elastic modulus both worsened with increased submersion times. Finite element analysis of the plates also predicted clinically significant increases in plate deviation under normal loading conditions. Our study demonstrates that extended submersion of absorbable plates during molding results in a significant loss of plate strength and stiffness. Further, our computer model predicts that these changes could result in an unacceptable plate deviation under normal loading conditions. Together, these data caution against overmolding of plates to avoid compromising their structural integrity.

  3. Plate Boundary Observatory in Taiwan

    NASA Astrophysics Data System (ADS)

    Yu, S.; Tsai, C.

    2003-12-01

    The island of Taiwan is situated in the plate boundary zone between the Eurasian and the Philippine Sea plates. The Philippine Sea plate is subducting northwestward underneath the Eurasian plate along the Ryukyu Trench in the north, while the Eurasian plate underthrusts the Philippine Sea plate along the Manila Trench in the south. Taking advantage of the extremely high strain rate in the Taiwan area, an integrated National Science Council project, Plate Boundary Observatory in Taiwan (PBOT), was initiated following the idea of US PBO. The scientific goal of PBOT is to observe the crustal deformation on various temporal and spatial scales in the Taiwan plate boundary zone employing available state of the art techniques for measuring crustal strain. The techniques include seismology, Global Positioning System (GPS), Interferometric Synthetic Aperture Radar (InSAR), borehole strainmeter, and earthquake geology. They are complementary to each other and form a complete spectrum of measuring various periods of crustal strain. The process of crustal deformation is generally quite slow. To obtain a reliable result, we usually need to persist in the observations for several years or even decades. Thus the PBOT should be a long-term project. In the first phase of 3 years period from 2003 to 2006, we will focus on the two areas, i.e. the plate suture zone in the Longitudinal Valley area and the western Taiwan where the higher seismic hazard is expected. A five-year national program, entitled ­Program for Earthquake and Active-fault Research (PEAR)­" was initiated after the disastrous 1999 Chi-Chi earthquake (Mw 7.6). As part of the PEAR, a dense continuous GPS array consisting of 150 new and about 50 pre-existing stations will be completed in the Taiwan area by the end of 2005 through a joint effort by the Central Weather Bureau and the Institute of Earth Sciences, Academia Sinica. The 50 new stations are going to be evenly distributed around the Taiwan Island. The other

  4. Subduction Drive of Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Hamilton, W. B.

    2003-12-01

    Don Anderson emphasizes that plate tectonics is self-organizing and is driven by subduction, which rights the density inversion generated as oceanic lithosphere forms by cooling of asthenosphere from the top. The following synthesis owes much to many discussions with him. Hinge rollback is the key to kinematics, and, like the rest of actual plate behavior, is incompatible with bottom-up convection drive. Subduction hinges (which are under, not in front of, thin leading parts of arcs and overriding plates) roll back into subducting plates. The Pacific shrinks because bounding hinges roll back into it. Colliding arcs, increasing arc curvatures, back-arc spreading, and advance of small arcs into large plates also require rollback. Forearcs of overriding plates commonly bear basins which preclude shortening of thin plate fronts throughout periods recorded by basin strata (100 Ma for Cretaceous and Paleogene California). This requires subequal rates of advance and rollback, and control of both by subduction. Convergence rate is equal to rates of rollback and advance in many systems but is greater in others. Plate-related circulation probably is closed above 650 km. Despite the popularity of concepts of plumes from, and subduction into, lower mantle, there is no convincing evidence for, and much evidence against, penetration of the 650 in either direction. That barrier not only has a crossing-inhibiting negative Clapeyron slope but also is a compositional boundary between fractionated (not "primitive"), sluggish lower mantle and fertile, mobile upper mantle. Slabs sink more steeply than they dip. Slabs older than about 60 Ma when their subduction began sink to, and lie down on and depress, the 650-km discontinuity, and are overpassed, whereas younger slabs become neutrally buoyant in mid-upper mantle, into which they are mixed as they too are overpassed. Broadside-sinking old slabs push all upper mantle, from base of oceanic lithosphere down to the 650, back under

  5. Effective characteristics of corrugated plates

    NASA Astrophysics Data System (ADS)

    Arkhangel'skii, A. F.; Gorbachev, V. I.

    2007-06-01

    Corrugated plates are widely used in modern constructions and structures, because they, in contrast to plane plates, possess greater rigidity. In many cases, such a plate can be modeled by a homogeneous anisotropic plate with certain effective flexural and tensional rigidities. Depending on the geometry of corrugations and their location, the equivalent homogeneous plate can also have rigidities of mutual influence. These rigidities allow one to take into account the influence of bending moments on the strain in the midplane and, conversely, the influence of longitudinal strains on the plate bending [1]. The behavior of the corrugated plate under the action of a load normal to the midsurface is described by equations of the theory of flexible plates with initial deflection. These equations form a coupled system of nonlinear partial differential equations with variable coefficients [2]. The dependence of the coefficients on the coordinates is determined by the corrugation geometry. In the case of a plate with periodic corrugation, the coefficients significantly vary within one typical element and depend on the values of local variables determined in each of the typical elements. There is a connection between the local and global variables, and therefore, the functions of local coordinates are simultaneously functions of global coordinates, which are sometimes called rapidly oscillating functions [3]. One of the methods for solving the equations with rapidly oscillating coefficients is the asymptotic method of small geometric parameter. The standard procedure of this method usually includes preparatory stages. At the first stage, as a rule, a rectangular periodicity cell is distinguished to be a typical element. At the second stage, the scale of global coordinates is changed so that the rectangular structure periodicity cells became square cells of size l × l. The third stage consists in passing to the dimensionless global coordinates relative to the plate

  6. High thermal capacity cold plate/hot plate

    NASA Technical Reports Server (NTRS)

    Hwangbo, H.; Mcever, W. S.

    1985-01-01

    The results of an analytical study to determine the feasibility of a novel two-phase cold plate/hot plate (CPHP) are presented. A key feature of the CPHP is the use of capillary forces to separate the liquid and vapor phases and distribute the liquid over the evaporating/condensing surface. The liquid phase is held by capillary forces in a reservoir and is carried to the evaporating surface by a wick. The reservoir is replenished at intervals from a valved external liquid supply line. In the hot plate mode, liquid accumulates in the reservoir and is removed by an external condensate line. Performance requirements for the device were capability of handling a power density of 4 watts/sq cm, an outlet quality (percentage of vapor flow to total flow) greater than 90 percent, and operation in a 0-g environment. An analytical model of CPHP operation was developed which concentrated on the liquid and vapor flows. It was found that the liquid carrying capillary grooves of rectangular cross-section gave significantly better predicted performance than V-shaped grooves. Using the analytical model, capillary groove width and length, vapor channel dimensions, and other parameters were selected to meet the performance requirements with a 100-percent margin.

  7. Maps, Plates, and Mount Saint Helens.

    ERIC Educational Resources Information Center

    Lary, Barbara E.; Krockover, Gerald H.

    1987-01-01

    Describes a laboratory activity on plate tectonics which focuses on the connection between plate tectonics and the different types of volcanoes. Provides questions for discussion and includes suggestions for extending the activity. (ML)

  8. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  9. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  10. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  11. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  12. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  13. 30 CFR 20.13 - Approval plate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturer shall attach, stamp, or mold an approval plate on the battery container or housing of each... has been adjudged safe for use in gassy and dusty mines. (b) Use of approval plate. Permission...

  14. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  15. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, P.J.

    1987-03-02

    A method of electrically inducing mechanical precompression of ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion. 2 figs.

  16. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  17. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, Peter J.

    1987-01-01

    A method of electrically inducing mechanical precompression of a ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion.

  18. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1986-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  19. Electroless metal plating of plastics

    DOEpatents

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  20. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1984-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  1. Ion plated electronic tube device

    DOEpatents

    Meek, T.T.

    1983-10-18

    An electronic tube and associated circuitry which is produced by ion plating techniques. The process is carried out in an automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

  2. Optical Near-Field Plates

    DTIC Science & Technology

    2015-04-08

    microscopy images of seven plasmonic color filters illuminated by the white microscope light. Scale bar is 10 µm. (b) Experimentally measured transmission... color filtering and spectral imaging ,” Nat. Comm. 1, 59 (2010). 3. H.-F. Shi and L. J. Guo, “Design of Plasmonic Near Field Plate at Opitical...wavelength. Plasmonic filters were developed and transmission color filtering was accomplished. The polarization property and the pitch-dependent

  3. Syncytial-Type Cell Plates

    PubMed Central

    Otegui, Marisa; Staehelin, L. Andrew

    2000-01-01

    Cell wall formation in the syncytial endosperm of Arabidopsis was studied by using high-pressure-frozen/freeze-substituted developing seeds and immunocytochemical techniques. The endosperm cellularization process begins at the late globular embryo stage with the synchronous organization of small clusters of oppositely oriented microtubules (∼10 microtubules in each set) into phragmoplast-like structures termed mini-phragmoplasts between both sister and nonsister nuclei. These mini-phragmoplasts produce a novel kind of cell plate, the syncytial-type cell plate, from Golgi-derived vesicles ∼63 nm in diameter, which fuse by way of hourglass-shaped intermediates into wide (∼45 nm in diameter) tubules. These wide tubules quickly become coated and surrounded by a ribosome-excluding matrix; as they grow, they branch and fuse with each other to form wide tubular networks. The mini-phragmoplasts formed between a given pair of nuclei produce aligned tubular networks that grow centrifugally until they merge into a coherent wide tubular network with the mini-phragmoplasts positioned along the network margins. The individual wide tubular networks expand laterally until they meet and eventually fuse with each other at the sites of the future cell corners. Transformation of the wide tubular networks into noncoated, thin (∼27 nm in diameter) tubular networks begins at multiple sites and coincides with the appearance of clathrin-coated budding structures. After fusion with the syncytial cell wall, the thin tubular networks are converted into fenestrated sheets and cell walls. Immunolabeling experiments show that the cell plates and cell walls of the endosperm differ from those of the embryo and maternal tissue in two features: their xyloglucans lack terminal fucose residues on the side chain, and callose persists in the cell walls after the cell plates fuse with the parental plasma membrane. The lack of terminal fucose residues on xyloglucans suggests that these cell wall

  4. Optimization of neutron imaging plate

    NASA Astrophysics Data System (ADS)

    Haga, Y. K.; Neriishi, K.; Takahashi, K.; Niimura, N.

    2002-07-01

    Considering the elementary processes of neutron detection occurring in the neutron imaging plate (NIP) has optimized the performance of NIP. For these processes, the color center creation efficiencies ( ɛcc values) have been experimentally determined with NIPs which have different mole fraction of photostimulated (PSL) material ( φPSL values) and different thickness ( t). The effectiveness of the optimization procedure has been demonstrated by the measurement of the neutron diffraction intensities from a hen egg-white lysozyme protein crystal.

  5. Plating Waste Sludge Metal Recovery.

    DTIC Science & Technology

    1985-05-30

    l - ~ ’.4 41 *4 7.1 4...34 L €5 ’ ’ . ’ " " r ,*: -: ,., -. . .,,:€ ,, .. € : ....- -1. PHASE I - UERATURE REVIEW Phase I of the project "Plating Waste Sludge Metal Recovery...8217’’,. ’.’.."..-’......’ ...’ , m .m llll- l ..m~ l : j nm~, l ~linn~ . l , b~~h~h , . r - r. -*1 . * , * . . , .d PHASE IV -

  6. PRETREATING URANIUM FOR METAL PLATING

    DOEpatents

    Wehrmann, R.F.

    1961-05-01

    A process is given for anodically treating the surface of uranium articles, prior to metal plating. The metal is electrolyzed in an aqueous solution of about 10% polycarboxylic acid, preferably oxalic acid, from 1 to 5% by weight of glycerine and from 1 to 5% by weight of hydrochloric acid at from 20 to 75 deg C for from 30 seconds to 15 minutes. A current density of from 60 to 100 amperes per square foot is used.

  7. Forming Weld Lands On Metal Plates

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1994-01-01

    Forming shoe pounds edge of newly inserted plate workpiece. After many passes of shoe and advances of plate, thick land builds up at edge. Workpiece heated to enable metal to flow without strain hardening. Proposed upset-forming process replaces relatively expensive, time-consuming, and wasteful process in which integral weld lands created by machining metal away from plates everywhere except at lands.

  8. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  9. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  10. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  11. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  12. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  13. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  14. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  15. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  16. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  17. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  18. Recent plate motions and crustal deformation

    SciTech Connect

    Lisowski, M. )

    1991-01-01

    Reports by U.S. workers on geodetic measurements of recent plate motions or crustal deformation published in 1987-1990 are reviewed. The review begins with global plate motions, proceeds through plate boundaries in California, Alaska, and the Pacific Northwest, and finishes with volcanic phenomena, monument stability and longevity, and GPS relative position measurements. 184 refs.

  19. Normal-Pressure Tests of Rectangular Plates

    NASA Technical Reports Server (NTRS)

    Ramberg, Walter; Mcpherson, Albert E; Levy, Samuel

    1942-01-01

    Report presents the results of normal-pressure tests made of 56 rectangular plates with clamped edges and of 5 plates with freely supported edges. Pressure was applied and the center deflection and the permanent set at the center were measured. For some of the plates, in addition, strains and contours were measured.

  20. Moving Divertor Plates in a Tokamak

    SciTech Connect

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  1. Episodic plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  2. Volcano spacing and plate rigidity

    SciTech Connect

    Brink, U. )

    1991-04-01

    In-plane stresses, which accompany the flexural deformation of the lithosphere under the load adjacent volcanoes, may govern the spacing of volcanoes in hotspot provinces. Specifically, compressive stresses in the vicinity of a volcano prevent new upwelling in this area, forcing a new volcano to develop at a minimum distance that is equal to the distance in which the radial stresses change from compressional to tensile (the inflection point). If a volcano is modeled as a point load on a thin elastic plate, then the distance to the inflection point is proportional to the thickness of the plate to the power of 3/4. Compilation of volcano spacing in seven volcanic groups in East Africa and seven volcanic groups of oceanic hotspots shows significant correlation with the elastic thickness of the plate and matches the calculated distance to the inflection point. In contrast, volcano spacing in island arcs and over subduction zones is fairly uniform and is much larger than predicted by the distance to the inflection point, reflecting differences in the geometry of the source and the upwelling areas.

  3. MTR plates modeling with MAIA

    SciTech Connect

    Marelle, V.; Dubois, S.; Ripert, M.; Noirot, J.

    2008-07-15

    MAIA is a thermo-mechanical code dedicated to the modeling of MTR fuel plates. The main physical phenomena modeled in the code are the cladding oxidation, the interaction between fuel and Al-matrix, the swelling due to fission products and the Al/fuel particles interaction. The creeping of the plate can be modeled in the mechanical calculation. MAIA has been validated on U-Mo dispersion fuel experiments such as IRIS 1 and 2 and FUTURE. The results are in rather good agreement with post-irradiation examinations. MAIA can also be used to calculate in-pile behavior of U{sub 3}Si{sub 2} plates as in the SHARE experiment irradiated in the SCK/Mol BR2 reactor. The main outputs given by MAIA throughout the irradiation are temperatures, cladding oxidation thickness, interaction thickness, volume fraction of meat constituents, swelling, displacements, strains and stresses. MAIA is originally a two-dimensional code but a three-dimensional version is currently under development. (author)

  4. Crustal genesis and plate tectonics

    NASA Astrophysics Data System (ADS)

    Yang-shen, Shi; Shu-feng, Yang; Ling-zhi, Guo; Huo-gen, Dong

    1991-02-01

    As a transitional zone between ocean and continent, the continental margins are important accreted belts of the granitic crust. Extensive granitoids of different geological ages and different genetic series occur in the continental margins of southeastern China. The granites in active continental margins of southeast China are divided into two genetic series by present authors as follows:(1) S-type granitoids in the interior of the continental plate; and (2) I-type granitoids in the margin of the continental plate. S-type and I-type granitoids of almost the same geological age are paired and belted in their spatial distribution parallel to the continental margin. These are referred to as "paired granite belts". Granitic continental crust genesis is closely related to the growth of paired granite belts. In Mt. Yunkai of southeastern China, Guangdong province, Early Paleozoic S-type granitoids have been produced as a result of transformation of Cambrian sediments during the processes of metamorphism, migmatization, granitization and remelting. Co-magmatic volcanic rocks are completely lacking in this area. Early Paleozoic I-type granitoids on the east side of Mt. Yunkai are distributed along the ancient continental margin. These rocks co-exist with comagmatic island-arc volcanic rocks of calc-alkaline series in this area. The above mentioned two types of granitoids are paired and belted. Similar paired granite belts exist around the world, such as in North America and southeastern Australia, and are interpreted to be products of post plate convergence, subduction and collision.

  5. Plate tectonics, habitability and life

    NASA Astrophysics Data System (ADS)

    Spohn, Tilman; Breuer, Doris

    2016-04-01

    The role of plate tectonics in defining habitability of terrestrial planets is being increasingly discussed (e.g., Elkins-Tanton, 2015). Plate tectonics is a significantly evolved concept with a large variety of aspects. In the present context, cycling of material between near surface and mantle reservoirs is most important. But increased heat transport through mixing of cold lithosphere with the deep interior and formation of continental crust may also matter. An alternative mechanism of material cycling between these reservoirs is hot-spot volcanism combined with crust delamination. Hot-spot volcanism will transport volatiles to the atmosphere while delamination will mix crust, possibly altered by sedimentation and chemical reactions, with the mantle. The mechanism works as long as the stagnant lithosphere plate has not grown thicker than the crust and as long as volcanic material is added onto the crust. Thermal evolution studies suggest that the mechanism could work for the first 1-2 Ga of planetary evolution. The efficiency of the mechanism is limited by the ratio of extrusive to intrusive volcanism, which is thought to be less than 0.25. Plate tectonics would certainly have an advantage by working even for more evolved planets. A simple, most-used concept of habitability requires the thermodynamic stability of liquid water on the surface of a planet. Cycling of CO2between the atmosphere, oceans and interior through subduction and surface volcanism is an important element of the carbonate-silicate cycle, a thermostat feedback cycle that will keep the atmosphere from entering into a runaway greenhouse. Calculations for a model Earth lacking plate tectonics but degassing CO2, N, and H2O to form a surface ocean and a secondary atmosphere (Tosi et al, 2016) suggest that liquid water can be maintained on the surface for 4.5Ga. The model planet would then qualify as habitable. It is conceivable that the CO2 buffering capability of its ocean together with silicate

  6. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  7. Steady state response of unsymmetrically laminated plates

    SciTech Connect

    Hosokawa, Kenji; Kawashima, Katsuya; Sakata, Toshiyuki

    1995-11-01

    A numerical approach for analyzing the forced vibration problem of a symmetrically laminated FRP (fiber reinforced plastic) composite plate was proposed by the authors. In the present paper, this approach is modified for application to an unsymmetrically laminated FRP composite plate. Numerical calculations are carried out for the clamped antisymmetrically laminated rectangular and elliptical plates which are a kind of unsymmetrically laminated plate. Then,, the effects of the lamina material and the fiber orientation angle on the steady state response are discussed. Furthermore, it is investigated that what structural damping factor is most influenced on the steady state response of an antisymmetrically laminated plate.

  8. Wheelspace windage cover plate for turbine

    DOEpatents

    Lathrop, Norman Douglas

    2002-01-01

    Windage cover plates are secured between the wheels and spacer of a turbine rotor to prevent hot flow path gas ingestion into the wheelspace cavities. Each cover plate includes a linear, axially extending body curved circumferentially with a radially outwardly directed wall at one axial end. The wall defines a axially opening recess for receiving a dovetail lug. The cover plate includes an axially extending tongue received in a circumferential groove of the spacer. The cover plate is secured with the tongue in the groove and dovetail lug in the recess. Lap joints between circumferentially adjacent cover plates are provided.

  9. Development of flat - plate solar plate collector - evaporator. Summary report

    SciTech Connect

    Abramzon, B.; Yaron, I.

    1981-11-01

    In the present study the thermal performance of a flat plate solar collector is analyzed theoretically for the case in which the working fluid may undergo a phase change within the tubes of the collector. In addition to the common domestic applications, such a collector - evaporator may be used as a generator of vapors for the production of mechanical or electrical energy, e.g. solar water pumps, solar power stations, etc., as well as for solar - powered absorption refrigeration machines, distillation installations, etc.

  10. Shear deformation in thick auxetic plates

    NASA Astrophysics Data System (ADS)

    Lim, Teik-Cheng

    2013-08-01

    This paper aims to understand the effect of auxeticity on shear deformation in thick plates. Three models for the shear correction factor of plates as a function of Poisson’s ratio were proposed: an analytical model, a cubic fit model and a modified model. Of these three, the cubic fit model exhibits the best accuracy over the entire range of Poisson’s ratio from -1 to 0.5. The extent of shear deformation is herein investigated using the example of uniformly loaded circular plates. It was found that the maximum deformation of such plates based on Mindlin theory approximates to those according to Kirchhoff theory when the Poisson’s ratio of the plate material is highly negative. When the Poisson’s ratio of the plate material is -1 and the edge of the plate is simply supported, the calculation of the maximum deflection by Mindlin theory simplifies into that by Kirchhoff theory. These results suggest that auxeticity reduces shear deformation in thick plates, permitting the use of classical plate theory for thick plates only if the plate material is highly auxetic.

  11. Absolute Plate Velocities from Seismic Anisotropy

    NASA Astrophysics Data System (ADS)

    Kreemer, Corné; Zheng, Lin; Gordon, Richard

    2015-04-01

    The orientation of seismic anisotropy inferred beneath plate interiors may provide a means to estimate the motions of the plate relative to the sub-asthenospheric mantle. Here we analyze two global sets of shear-wave splitting data, that of Kreemer [2009] and an updated and expanded data set, to estimate plate motions and to better understand the dispersion of the data, correlations in the errors, and their relation to plate speed. We also explore the effect of using geologically current plate velocities (i.e., the MORVEL set of angular velocities [DeMets et al. 2010]) compared with geodetically current plate velocities (i.e., the GSRM v1.2 angular velocities [Kreemer et al. 2014]). We demonstrate that the errors in plate motion azimuths inferred from shear-wave splitting beneath any one tectonic plate are correlated with the errors of other azimuths from the same plate. To account for these correlations, we adopt a two-tier analysis: First, find the pole of rotation and confidence limits for each plate individually. Second, solve for the best fit to these poles while constraining relative plate angular velocities to consistency with the MORVEL relative plate angular velocities. The SKS-MORVEL absolute plate angular velocities (based on the Kreemer [2009] data set) are determined from the poles from eight plates weighted proportionally to the root-mean-square velocity of each plate. SKS-MORVEL indicates that eight plates (Amur, Antarctica, Caribbean, Eurasia, Lwandle, Somalia, Sundaland, and Yangtze) have angular velocities that differ insignificantly from zero. The net rotation of the lithosphere is 0.25±0.11° Ma-1 (95% confidence limits) right-handed about 57.1°S, 68.6°E. The within-plate dispersion of seismic anisotropy for oceanic lithosphere (σ=19.2° ) differs insignificantly from that for continental lithosphere (σ=21.6° ). The between-plate dispersion, however, is significantly smaller for oceanic lithosphere (σ=7.4° ) than for continental

  12. An understanding of HSLA-65 plate steels

    NASA Astrophysics Data System (ADS)

    Sampath, K.

    2006-02-01

    HSLA-65 plate steels can be produced using one of five plate manufacturing techniques: normalizing, controlled rolling (CR), controlled rolling followed by accelerated cooling (CR-AC), direct quenching and tempering (DQT), or conventional quenching and tempering (Q&T). The HSLA-65 steels are characterized by low carbon content and low alloy content, and they exhibit a low carbon equivalent that allows improved plate weldability. These characteristics in turn (a) provide the steel plate with a refined microstructure that ensures high strength and toughness; (b) eliminate or substantially reduce the need for preheating during welding; (c) resist susceptibility to hydrogen-assisted cracking (HAC) in the weld heat affected zone (HAZ) when fusion (arc) welded using low heat-input conditions; and (d) depending on section thickness, facilitate high heat-input welding (about 2 kJ/mm) without significant loss of strength or toughness in the HAZ. However, application of this plate manufacturing process and of these controls produces significant differences in the metallurgical structure and range of mechanical properties of the HSLA-65 plate steels both among themselves and versus conventional higher strength steel (HSS) plates. For example, among the HSLA-65 plate steels, those produced by Q&T exhibit minimal variability in mechanical properties, especially in thicker plates. Besides variability in mechanical properties depending on plate thickness, the CR and CR-AC plate steels exhibit a relatively higher yield strength to ultimate tensile strength (YS/UTS) ratio than do DQT and Q&T steels. Such differences in processing and properties of HSLA-65 plate steels could potentially affect the selection and control of various secondary fabrication practices, including arc welding. Consequently, fabricators must exercise extreme caution when transferring allowable limits of certified secondary fabrication practices from one type of HSLA-65 plate steel to another, even for the

  13. When Did Plate Tectonics Begin

    NASA Astrophysics Data System (ADS)

    Brown, M.

    2015-12-01

    Present-day plate tectonics on Earth is characterized by asymmetric (one-sided) subduction, but how do we recognize the imprint of subduction in the geologic record? How do we weigh global (commonly younger) vs local (commonly older) datasets or distinguish initiation from episodic from continuous subduction? How reliable are data gaps? Characteristics of the Paleozoic record of subduction include calc-alkaline magmatism, blueschist/UHP metamorphism and collisional orogenesis, and ophiolites as representatives of former ocean lithosphere. Are these characteristic rocks preserved in Proterozoic, Archean and Hadean crust? Does a hotter mantle, higher heat production and weaker lithosphere modify or eliminate these features? What preceded subduction and how do we recognize that regime? Are rock associations or geochemical fingerprints reliable? Does reworking and overprinting modify geochemical fingerprints? Proposals for the start of plate tectonics have been based on: persistence of isotope anomalies/fractionated chemical domains in the mantle; changes in chemistry of magmatic rocks, rates of crustal growth vs reworking, and sites of growth; the metamorphic record, particularly the first appearance of contrasting thermal gradients or eclogite (including evidence from mineral inclusions in diamonds) or UHP metamorphic rocks; stabilization of cratonic lithosphere and formation of supercratons, and the beginning of the Proterozoic supercontinent cycle; the end of the flat Earth, emergence of continents, development of significant topography, changes in the style of orogeny and the rise in atmospheric oxygen; and, the appearance of passive margins and changes in the style of sedimentation. Estimates of the timing have varied from the Hadean to Neoproterozoic. I will summarize evidence for a growing consensus that the late Mesoarchean to early Paleoproterozoic was a 700 Myr long period of transition to continuous (?) subduction and global (?) mobile-lid plate tectonics.

  14. Non-cyanide silver plating

    SciTech Connect

    Dini, J.W.

    1995-11-07

    Lawrence Livermore National Laboratory (LLNL) and Technic, Inc. have entered into a CRADA (Cooperative Research and Development Agreement) with the goal of providing industry with an environmentally benign alternative to the presently used silver cyanide plating process. This project has been in place for about six months and results are quite promising. The main objective, that of deposition of deposits as thick as 125 um (5 mils), has been met. Property data such as stress and hardness have been obtained and the structure of the deposit has been analyzed via metallography and x-ray diffraction. These results will be presented in this paper, along with plans for future work.

  15. Turbulent flows near flat plates

    NASA Astrophysics Data System (ADS)

    Kambe, R.; Imamura, T.; Doi, M.

    1980-08-01

    The method to study the effect of the plate moving in the homogeneous or isotropic turbulence is presented. The crucial point of this method is to solve the Orr-Sommerfeld like equation, which is satisfied by the kernel of the Wiener-Hermite expansion of the velocity field, under the inhomogeneous boundary condition. In the special case of constant mean flow, our method gives the same result as that of Hunt and Graham and succeeds in explaining the experimental results of Thomas and Hancock. The method is also applied to the case of nonuniform mean flow, where the shear effect comes up.

  16. Adherent protective coatings plated on magnesium-lithium alloy

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Zinc is plated on a magnesium-lithium alloy by using a modification of the standard zinc-plate immersion bath. Further protection is given the alloy by applying a light plating of copper on the zinc plating. Other metals are plated on the copper by using conventional plating baths.

  17. Yield Surfaces for Anisotropic Plates

    NASA Astrophysics Data System (ADS)

    Walker, J. D.; Thacker, B. H.

    1999-06-01

    Modern aerospace systems are incorporating composite materials into their structures. Often, the composite materials are anisotropic in their mechanical response due to the geometric layout of fibers. For many years, the failure surfaces of anisotropic materials were thought to be characterizable by a quadratic function in the stress, often referred to as a Tsai-Wu yield surface, or, in a more restrictive form, a Tsai-Hill yield surface. Such a representation does not work for materials that are strong in two directions and weak in one direction, which, unfortunately, is the case of most interest since it represents most composite plates. This paper demonstrates the impossibility of modeling the failure surface with both the Tsai-Wu and Tsai-Hill failure surfaces. We then present a yield surface based on the lemniscate, which is quartic in the stress. This new yield surface addresses the case of strong in two directions and weak in one. Calculations with a fragment impacting a composite plate modeled with the new yield surface are presented. Modifications of the yield surface are presented to allow, in a limited way, materials that are both anisotropic and have differing strengths in tension and compression.

  18. Silicon-micromachined microchannel plates

    NASA Astrophysics Data System (ADS)

    Beetz, Charles P.; Boerstler, Robert; Steinbeck, John; Lemieux, Bryan; Winn, David R.

    2000-03-01

    Microchannel plates (MCP) fabricated from standard silicon wafer substrates using a novel silicon micromachining process, together with standard silicon photolithographic process steps, are described. The resulting SiMCP microchannels have dimensions of ˜0.5 to ˜25 μm, with aspect ratios up to 300, and have the dimensional precision and absence of interstitial defects characteristic of photolithographic processing, compatible with positional matching to silicon electronics readouts. The open channel areal fraction and detection efficiency may exceed 90% on plates up to 300 mm in diameter. The resulting silicon substrates can be converted entirely to amorphous quartz (qMCP). The strip resistance and secondary emission are developed by controlled depositions of thin films, at temperatures up to 1200°C, also compatible with high-temperture brazing, and can be essentially hydrogen, water and radionuclide-free. Novel secondary emitters and cesiated photocathodes can be high-temperature deposited or nucleated in the channels or the first strike surface. Results on resistivity, secondary emission and gain are presented.

  19. Petrologic implications of plate tectonics.

    PubMed

    Yoder, H S

    1971-07-30

    Petrologists can make significant contributions to the plate tectonic concept. Fixing the stability fields of the principal rock types involved will provide the limits of pressure and temperature of the various environments. Experimental determination of the partition coefficients of the trace elements will be helpful. Studies of the partial melting behavior of possible parental materials in the absence and presence of water, especially the undersaturated region, will contribute to the understanding of magma production. Experimental observations on the rheological properties of the peridotites below and just above the solidus will lead to a better evaluation of the convective mechanism. Measurement of the fundamental properties of rocks, such as the density of solids and liquids at high pressures and temperatures, would contribute to understanding the concepts of diapiric rise, magma segregation, and the low-velocity zone. Broader rock sampling of the oceanic areas of all environments will do much to define the petrologic provinces. The field petrologist specializing in the Paleozoic regions and Precambrian shields can contribute by examining those regions for old plate boundaries and devising new criteria for their recognition.

  20. Wide-Field Plate Database

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M. K.; Stavrev, K. Y.; Tsvetkova, K. P.; Semkov, E. H.; Mutatov, A. S.

    The Wide-Field Plate Database (WFPDB) and the possibilities for its application as a research tool in observational astronomy are presented. Currently the WFPDB comprises the descriptive data for 400 000 archival wide field photographic plates obtained with 77 instruments, from a total of 1 850 000 photographs stored in 269 astronomical archives all over the world since the end of last century. The WFPDB is already accessible for the astronomical community, now only in batch mode through user requests sent by e-mail. We are working on on-line interactive access to the data via INTERNET from Sofia and parallel from the Centre de Donnees Astronomiques de Strasbourg. (Initial information can be found on World Wide Web homepage URL http://www.wfpa.acad.bg.) The WFPDB may be useful in studies of a variety of astronomical objects and phenomena, andespecially for long-term investigations of variable objects and for multi-wavelength research. We have analysed the data in the WFPDB in order to derive the overall characteristics of the totality of wide-field observations, such as the sky coverage, the distributions by observation time and date, by spectral band, and by object type. We have also examined the totality of wide-field observations from point of view of their quality, availability and digitisation. The usefulness of the WFPDB is demonstrated by the results of identification and investigation of the photometrical behaviour of optical analogues of gamma-ray bursts.

  1. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  2. Rapidly Moving Divertor Plates In A Tokamak

    SciTech Connect

    S. Zweben

    2011-05-16

    It may be possible to replace conventional actively cooled tokamak divertor plates with a set of rapidly moving, passively cooled divertor plates on rails. These plates would absorb the plasma heat flux with their thermal inertia for ~10-30 sec, and would then be removed from the vessel for processing. When outside the tokamak, these plates could be cooled, cleaned, recoated, inspected, and then returned to the vessel in an automated loop. This scheme could provide nearoptimal divertor surfaces at all times, and avoid the need to stop machine operation for repair of damaged or eroded plates. We describe various possible divertor plate designs and access geometries, and discuss an initial design for a movable and removable divertor module for NSTX-U.

  3. Silencing using flexible plate in a duct

    NASA Astrophysics Data System (ADS)

    Ramamoorthy, Sripriya; Grosh, Karl; Nawar, Tony G.

    2002-11-01

    A flexible plate interacting with air in a duct can provide passive means for low frequency broadband transmission loss. The sensitivity of the system to various parameters including unintentionally applied tension, effect of external fluid loading, lateral plate cross modes, structural and acoustic boundary condition are analyzed through experimental measurements and theoretical predictions. In order to avoid breakout noise, a backing cavity can be introduced below the plate. This introduces differences in filtering characteristics. Compared to plate in a single duct, the two-duct system will have higher plate resonance frequencies due to cavity loading on the plate. Means to achieve low frequency broadband transmission loss using two-duct silencers will be discussed. Significance of three dimensionality of the problem will be brought out by comparing the results of three-dimensional finite-element analysis with experimental data. Successful designs and experiments for low frequency attenuation will be presented. [Work supported by NSF and ONR.

  4. Excitation and Characterization of Chladni Plate Patterns

    NASA Astrophysics Data System (ADS)

    Bourke, Shannon; Behringer, Ernest

    2011-04-01

    When a thin metal plate with a small amount of sand on it is made to vibrate, aesthetically pleasing sand patterns can form along the nodal lines of the plate. These symmetric patterns are called Chladni Patterns. Students taking PHY 101 Physical Science in the Arts at Eastern Michigan University create these patterns by pulling a violin bow across the edge of a plate, or by using a mechanical oscillator to drive the center of a plate. These two methods only allow a small subset of all possible points on the plate to be excited. We designed and built an electronic device that allows its user to excite the plate at any point. We present patterns created with this electronic device and other methods, and describe ways to model the observed patterns.

  5. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1986-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  6. Flutter of laminated plates in supersonic flow

    NASA Technical Reports Server (NTRS)

    Sawyer, J. W.

    1975-01-01

    A solution procedure was developed using linear small deflection theory for the flutter of simply supported laminated plates. For such plates, the bending and extensional governing equations are coupled and have cross-stiffness terms which do not appear in classical plate theory. An extended Galerkin method is used to obtain approximate solutions to the governing equations, and the aerodynamic pressure loading used in the analysis is that given by linear piston theory with flow at arbitrary cross-flow angle. A limited parametric study was conducted for typical laminated composite plates. The calculations show that both the bending-extensional coupling and the cross-stiffness terms have a large destabilizing effect on flutter. Since classical plate theory does not consider bending-extensional coupling and cross stiffness terms, it usually gives inaccurate and nonconservative flutter boundaries for laminated plates.

  7. Coupling between plate vibration and acoustic radiation

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Maestrello, Lucio; Bayliss, Alvin

    1992-01-01

    A detailed numerical investigation of the coupling between the vibration of a flexible plate and the acoustic radiation is performed. The nonlinear Euler equations are used to describe the acoustic fluid while the nonlinear plate equation is used to describe the plate vibration. Linear, nonlinear, and quasi-periodic or chaotic vibrations and the resultant acoustic radiation are analyzed. We find that for the linear plate response, acoustic coupling is negligible. However, for the nonlinear and chaotic responses, acoustic coupling has a significant effect on the vibration level as the loading increases. The radiated pressure from a plate undergoing nonlinear or chaotic vibrations is found to propagate nonlinearly into the far-field. However, the nonlinearity due to wave propagation is much weaker than that due to the plate vibrations. As the acoustic wave propagates into the far-field, the relative difference in level between the fundamental and its harmonics and subharmonics decreases with distance.

  8. Coupling between plate vibration and acoustic radiation

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Maestrello, Lucio; Bayliss, Alvin

    1993-01-01

    A detailed numerical investigation of the coupling between the vibration of a flexible plate and the acoustic radiation is performed. The nonlinear Euler equations are used to describe the acoustic fluid while the nonlinear plate equation is used to describe the plate vibration. Linear, nonlinear, and quasi-periodic or chaotic vibrations and the resultant acoustic radiation are analyzed. We find that for the linear plate response, acoustic coupling is negligible. However, for the nonlinear and chaotic responses, acoustic coupling has a significant effect on the vibration level as the loading increases. The radiated pressure from a plate undergoing nonlinear or chaotic vibrations is found to propagate nonlinearly into the far field. However, the nonlinearity due to wave propagation is much weaker than that due to the plate vibrations. As the acoustic wave propagates into the far field, the relative difference in level between the fundamental and its harmonics and subharmonics decreases with distance.

  9. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon; Larcher, Steven; Henderson, Gena; Tran, Donald

    2011-01-01

    Over the years there have been several occurrences of damage to Space Shuttle Orbiter cold plates during removal and replacement of avionics boxes. Thus a process improvement team was put together to determine ways to prevent these kinds of damage. From this effort there were many solutions including, protective covers, training, and improved operations instructions. The focus of this paper is to explain the cold plate damage problem and the corrective actions for preventing future damage to aerospace avionics cold plate designs.

  10. Finite Element Anlaysis of Laminated Composite Plates

    DTIC Science & Technology

    1988-09-01

    4.2, results depicting maximum displacement obtained using 2 x 2 integration points, 3 x 3 integration points and ’ heterosis ’ [Ref. 4] elements are...thick and thin plates. This element gives better predictions for thick plates than heterosis ele- ment, however, for thin plates, heterosis element...results showing the normalized maximum displacements are shown in Figure 4.8. The heterosis element results in about ten percent error while the

  11. High performance flat plate solar collector

    NASA Technical Reports Server (NTRS)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  12. High speed thin plate fatigue crack monitor

    NASA Technical Reports Server (NTRS)

    Wincheski, Buzz A. (Inventor); Heyman, Joseph S. (Inventor); Namkung, Min (Inventor); Fulton, James P. (Inventor)

    1996-01-01

    A device and method are provided which non-destructively detect crack length and crack geometry in thin metallic plates. A non-contacting vibration apparatus produces resonant vibrations without introducing extraneous noise. Resulting resonant vibration shifts in cracked plates are correlated to known crack length in plates with similar resonant vibration shifts. In addition, acoustic emissions of cracks at resonance frequencies are correlated to acoustic emissions from known crack geometries.

  13. Wave propagation in metamaterial lattice sandwich plates

    NASA Astrophysics Data System (ADS)

    Fang, Xin; Wen, Jihong; Yin, Jianfei; Yu, Dianlong

    2016-04-01

    This paper designed a special acoustic metamaterial 3D Kagome lattice sandwich plate. Dispersion properties and vibration responses of both traditional plate and metamaterial plate are investigated based on FEA methods. The traditional plate does not have low-frequency complete bandgaps, but the metamaterial plate has low-frequency complete bandgap (at 620Hz) coming from the symmetrical local cantilever resonators. The bandgap frequency is approximate to the first-order natural frequency of the oscillator. Complex wave modes are analyzed. The dispersion curves of longitudinal waves exist in the flexural bandgap. The dispersion properties demonstrate the metamaterial design is advantageous to suppress the low-frequency flexural wave propagation in lattice sandwich plate. The flexural vibrations near the bandgap are also suppressed efficiently. The longitudinal excitation stimulates mainly longitudinal waves and lots of low-frequency flexural vibration modes are avoided. Furthermore, the free edge effects in metamaterial plate provide new method for damping optimizations. The influences of damping on vibrations of the metamaterial sandwich plate are studied. Damping has global influence on the wave propagation; stronger damping will induce more vibration attenuation. The results enlighten us damping and metamaterial design approaches can be unite in the sandwich plates to suppress the wave propagations.

  14. Locomotion of a flapping flexible plate

    NASA Astrophysics Data System (ADS)

    Hua, Ru-Nan; Zhu, Luoding; Lu, Xi-Yun

    2013-12-01

    The locomotion of a flapping flexible plate in a viscous incompressible stationary fluid is numerically studied by an immersed boundary-lattice Boltzmann method for the fluid and a finite element method for the plate. When the leading-edge of the flexible plate is forced to heave sinusoidally, the entire plate starts to move freely as a result of the fluid-structure interaction. Mechanisms underlying the dynamics of the plate are elucidated. Three distinct states of the plate motion are identified and can be described as forward, backward, and irregular. Which state to occur depends mainly on the heaving amplitude and the bending rigidity of the plate. In the forward motion regime, analysis of the dynamic behaviors of the flapping flexible plate indicates that a suitable degree of flexibility can improve the propulsive performance. Moreover, there exist two kinds of vortex streets in the downstream of the plate which are normal and deflected wake. Further the forward motion is compared with the flapping-based locomotion of swimming and flying animals. The results obtained in the present study are found to be consistent with the relevant observations and measurements and can provide some physical insights into the understanding of the propulsive mechanisms of swimming and flying animals.

  15. The floor plate: multiple cells, multiple signals.

    PubMed

    Placzek, Marysia; Briscoe, James

    2005-03-01

    One of the key organizers in the CNS is the floor plate - a group of cells that is responsible for instructing neural cells to acquire distinctive fates, and that has an important role in establishing the elaborate neuronal networks that underlie the function of the brain and spinal cord. In recent years, considerable controversy has arisen over the mechanism by which floor plate cells form. Here, we describe recent evidence that indicates that discrete populations of floor plate cells, with characteristic molecular properties, form in different regions of the neuraxis, and we discuss data that imply that the mode of floor plate induction varies along the anteroposterior axis.

  16. Fuel cell cooler-humidifier plate

    DOEpatents

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  17. Plate Tectonics: A Paradigm under Threat.

    ERIC Educational Resources Information Center

    Pratt, David

    2000-01-01

    Discusses the challenges confronting plate tectonics. Presents evidence that contradicts continental drift, seafloor spreading, and subduction. Reviews problems posed by vertical tectonic movements. (Contains 242 references.) (DDR)

  18. Modal interaction in postbuckled plates. Theory

    NASA Technical Reports Server (NTRS)

    Thurston, Gaylen A.

    1989-01-01

    Plates can have more than one buckled solution for a fixed set of boundary conditions. The theory for the identification and the computation of multiple solutions in buckled plates is examined. The theory predicts modal interaction (which is also called change in buckle pattern or secondary buckling) in experiments on certain plates with multiple theoretical solutions. A set of coordinate functions is defined for Galerkin's method so that the von Karman plate equations are reduced to a coupled set of cubic equations in generalized coordinates that are uncoupled in the linear terms. An iterative procedure for solving modal interaction problems is suggested based on this cubic form.

  19. Yield surfaces for anisotropic plates

    NASA Astrophysics Data System (ADS)

    Walker, J. D.; Thacker, B. H.

    2000-04-01

    Aerospace systems are incorporating composite materials into their structures. The composite materials are often anisotropic in mechanical response due to their geometric layout. For many years, the failure surfaces of anisotropic materials were thought to be characterizable by a quadratic function in the stress, referred to as a Tsai-Wu yield surface, or, in a more restrictive form, a Tsai-Hill yield surface. Such a representation does not work for materials that are strong in two directions and weak in one direction, which is the case of most interest since it represents fiber/epoxy composite plates. This paper demonstrates the impossibility of modeling the failure surface with either the Tsai-Wu or Tsai-Hill failure surfaces. A yield surface is presented based on the lemniscate, which is quartic in the stress. This new yield surface addresses the case of strong in two directions and weak in one.

  20. Background events in microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Vallerga, J.; Wargelin, B.

    1988-01-01

    Measurements have been made to assess the characteristics and origins of background events in microchannel plates (MCPs). An overall background rate of about 0.4 events/sq cm persec has been achieved consistently for MCPs that have been baked and scrubbed. The temperature and gain of the MCPs are found to have no significant effect on the background rate. Detection of 1.46-MeV gamma rays from the MCP glass confirms the presence of K-40, with a concentration of 0.0007 percent, in MCP glass. It is shown that beta decay from K-40 is sufficient to cause the background rate and spectrum observed. Anticoincidence measurements indicate the the background rate caused by cosmic ray interactions is small (less than 0.016 events/sq cm per sec).

  1. Composition of the continental plates

    USGS Publications Warehouse

    Gilluly, J.

    1954-01-01

    The structures of continental plates and of oceanic basins suggested by several seismologists are utilized to estimate the relative volumes of sial and sima in the earth's crust. It seems that sial of the composition of the average igneous rock constitutes fully 26% and perhaps as much as 43% of the total crust. This ratio is far higher than seems likely if the sial had been entirely derived through fractional crystallization of a basaltic magma. The relative paucity of intermediate rocks as compared with granite and gabbro in the crust points in the same direction. The tentative conclusion is reached that the sial owes a large part of its volume to some process other than fractional crystallization of basalt-possibly to the emanation of low-melting constituents such as water, silica, potassa, soda, and alumina directly from the mantle to the crust. ?? 1954 Springer-Verlag.

  2. Inter- and intra-plate deformation at North American plate boundaries

    NASA Technical Reports Server (NTRS)

    Beavan, John

    1986-01-01

    Alaska tectonics and earthquake hazard studies; Southern California tectonics (block rotation); spreading near the Salton Trough; California plate motion (fault zone kinematics); and Caribbean plate motion investigations are examined.

  3. A Treatise on Equivalent-Plate Stiffnesses for Stiffened Laminated-Composite Plates and Plate-Like Lattices

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    2011-01-01

    A survey of studies conducted since 1914 on the use of equivalent-plate stiffnesses in modeling the overall, stiffness-critical response of stiffened plates and shells is presented. Two detailed, comprehensive derivations of first-approximation equivalent-plate stiffnesses are also presented that are based on the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. Equivalent-plate stiffness expressions, and a corresponding symbolic manipulation computer program, are also presented for several different stiffener configurations. These expressions are very general and exhibit the full range of anisotropies permitted by the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. The expressions presented in the present study were also compared with available, previously published results. For the most part, the previously published results are for special cases of the general expressions presented herein and are almost in complete agreement. Analysis is also presented that extends the use of the equivalent-plate stiffness expressions to sandwich plates.

  4. Thickness dependence of the Casimir force between a magnetodielectric plate and a diamagnetic plate

    SciTech Connect

    Inui, Norio

    2011-11-15

    This paper examines the repulsive Casimir force between a magnetodielectric plate, with static permeability greater than static permittivity, and a diamagnetic plate. As the thickness of the magnetodielectric plate is decreased, the attractive component of the Casimir force decreases more than the repulsive one. This effect makes the net Casimir force repulsive, and a larger repulsive Casimir force is generated compared to the Casimir force between the plates with infinite thickness.

  5. Evaluation of brush plated alloys as substitutes for tank plated hard chromium

    SciTech Connect

    Durham, H.B.; Hooper, A.M.

    1995-11-01

    This paper summarizes results obtained from a test program conducted in cooperation with Tinker Air Force Base (TAFB) in 1993 for the purpose of evaluating the potential of using brush plated alloys as replacements for tank plated hard chromium which is used in the overhaul of jet engines. Tank plating is energy expensive and generates waste products in several of the plating steps. Test specimens used in this study were fabricated from carbon steel, chromium-based stainless steel, and nickel-based stainless steel. Baseline specimens were tank plated with hard chromium or with a soft nickel capped with hard chromium. The specimens were tested for fatigue, thickness, microhardness, Taber wear, and Falex pin and vee block wear. All test were conducted in accordance with standard procedures of the American Society for Testing and Materials (ASTM). Test results obtained from the baseline specimens were compared with those obtained from specimens which had been coated with the three brush plated layered alloy solutions used in this evaluation. Results of this study show that brush plated alloy coatings appear promising as alternatives to tank plated hard chromium. Some data quality problems were encountered during testing, so at this time, definitive statements concerning the use of brush plating alloys as an acceptable alternative to tank plated hard chromium in critical TAFB maintenance, cannot be made. Although these tests results are not positive for TAFB`s operation, users of hard chromium tank plating with less critical applications may find brush plated coatings a suitable alternative. 1 ref.

  6. Simulation of Evolutive Plate Tectonics: the Size of Plates Depends on Mantle Temperature

    NASA Astrophysics Data System (ADS)

    Grigne, C.; Combes, M.

    2013-12-01

    We use a dynamic model of plate tectonics based on a multiagent approach, in a 2D cylindrical geometry (Combes et al., 2012), to study how evolutive plate tectonics affect the long term thermal state of the mantle, and in return, to analyze the relationship between the mantle mean temperature and the geometry of plate tectonics. Our model accounts for first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. We show that when processes for plate boundary creation (subduction initiation and ridge creation) are relying on a brittle criterion, namely when a fixed yield strength has to be reached, the average size of plates adapts to the mantle thermal state: longer plates are obtained for a hotter mantle, which implies a maximum seafloor age that remains fairly high throughout Earth's thermal history and limits mantle heat loss. This is consistent with petrological and geochemical constraints on Earth's cooling history. Important fluctuations in the mantle heat flux and velocities of plates are obtained on a timescale of a few hundred Myr, but on the long term, the relationship between the average wavelength of plate tectonics and mantle temperature can be explained by a simple scaling law. Recent compilations of geological records infer that passive margins had longer lifespans in the past (e.g. Bradley 2008; 2011), which has been linked to 'sluggish' plate tectonics and slow plates in the Precambrian (Korenaga, 2006). Our simulations outputs include lifespans of tectonic entities such as passive margins, as well as statistical data about events of plates reorganizations. We obtain faster plates in the past than at present day, but counterintuitively we also observe a low episodicity of tectonic

  7. High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader

    NASA Astrophysics Data System (ADS)

    Feng, Steve; Tseng, Derek; di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-12-01

    Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of performing AST without the need for trained diagnosticians. Our system includes a 3D-printed smartphone attachment that holds and illuminates the MTP using a light-emitting-diode array. An inexpensive optical fiber-array enables the capture of the transmitted light of each well through the smartphone camera. A custom-designed application sends the captured image to a server to automatically determine well-turbidity, with results returned to the smartphone in ~1 minute. We tested this mobile-reader using MTPs prepared with 17 antibiotics targeting Gram-negative bacteria on clinical isolates of Klebsiella pneumoniae, containing highly-resistant antimicrobial profiles. Using 78 patient isolate test-plates, we demonstrated that our mobile-reader meets the FDA-defined AST criteria, with a well-turbidity detection accuracy of 98.21%, minimum-inhibitory-concentration accuracy of 95.12%, and a drug-susceptibility interpretation accuracy of 99.23%, with no very major errors. This mobile-reader could eliminate the need for trained diagnosticians to perform AST, reduce the cost-barrier for routine testing, and assist in spatio-temporal tracking of bacterial resistance.

  8. High-throughput and automated diagnosis of antimicrobial resistance using a cost-effective cellphone-based micro-plate reader

    PubMed Central

    Feng, Steve; Tseng, Derek; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-01-01

    Routine antimicrobial susceptibility testing (AST) can prevent deaths due to bacteria and reduce the spread of multi-drug-resistance, but cannot be regularly performed in resource-limited-settings due to technological challenges, high-costs, and lack of trained professionals. We demonstrate an automated and cost-effective cellphone-based 96-well microtiter-plate (MTP) reader, capable of performing AST without the need for trained diagnosticians. Our system includes a 3D-printed smartphone attachment that holds and illuminates the MTP using a light-emitting-diode array. An inexpensive optical fiber-array enables the capture of the transmitted light of each well through the smartphone camera. A custom-designed application sends the captured image to a server to automatically determine well-turbidity, with results returned to the smartphone in ~1 minute. We tested this mobile-reader using MTPs prepared with 17 antibiotics targeting Gram-negative bacteria on clinical isolates of Klebsiella pneumoniae, containing highly-resistant antimicrobial profiles. Using 78 patient isolate test-plates, we demonstrated that our mobile-reader meets the FDA-defined AST criteria, with a well-turbidity detection accuracy of 98.21%, minimum-inhibitory-concentration accuracy of 95.12%, and a drug-susceptibility interpretation accuracy of 99.23%, with no very major errors. This mobile-reader could eliminate the need for trained diagnosticians to perform AST, reduce the cost-barrier for routine testing, and assist in spatio-temporal tracking of bacterial resistance. PMID:27976700

  9. Finite Element Analysis of Magnetoelastic Plate Problems.

    DTIC Science & Technology

    1981-08-01

    deformation and in the incremental large deformation analysis, respectively. The classical Kirchhoff assumption of the undeformable normal to the midsurface is...current density , is constant across the thickness of the plate and is parallel to the midsurface of the plate; (2) the normal component of the

  10. Analytical Tripping Loads for Stiffened Plates

    DTIC Science & Technology

    1993-12-01

    extensional strains at the midsurface of the plate are negli- gible. 2 (vii) The incremental buckling displacements may be approximated by the...extensional strains at the midsurface of the plate are given by 3 el = ul + ! e12 = +VI + WIW2), e22 = V2 + 2 The strains in the beam are denoted by

  11. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  12. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  13. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  14. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  15. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  16. Plate Tectonic Cycle. K-6 Science Curriculum.

    ERIC Educational Resources Information Center

    Blueford, J. R.; And Others

    Plate Tectonics Cycle is one of the units of a K-6 unified science curriculum program. The unit consists of four organizing sub-themes: (1) volcanoes (covering formation, distribution, and major volcanic groups); (2) earthquakes (with investigations on wave movements, seismograms and sub-suface earth currents); (3) plate tectonics (providing maps…

  17. Computing relative plate velocities: a primer

    SciTech Connect

    Bevis, M.

    1987-08-01

    Standard models of present-day plate motions are framed in terms of rates and poles of rotation, in accordance with the well-known theorem due to Euler. This article shows how computation of relative plate velocities from such models can be viewed as a simple problem in spherical trigonometry. A FORTRAN subroutine is provided to perform the necessary computations.

  18. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  19. Roll-forming tubes to header plates

    NASA Technical Reports Server (NTRS)

    Kramer, K.

    1976-01-01

    Technique has been developed for attaching and sealing tubes to header plates using a unique roll-forming tool. Technique is useful for attaching small tubes which are difficult to roll into conventional grooves in header plate tube holes, and for attaching when welding, brazing, or soldering is not desirable.

  20. Layered Plating Specimens For Mechanical Tests

    NASA Technical Reports Server (NTRS)

    Thompson, Linda B.; Flowers, Cecil E.

    1991-01-01

    Layered specimens readily made in standard sizes for tensile and other tests of mechanical properties. Standard specimen of metal ordinarily difficult to plate to standard grip thickness or diameter made by augmentation with easier-to-plate material followed by machining to standard size and shape.

  1. Improved nickel plating of Inconel X-750

    NASA Technical Reports Server (NTRS)

    Farmer, M. E.; Feeney, J. E.; Kuster, C. A.

    1969-01-01

    Electroplating technique with acid pickling provides a method of applying nickel plating on Inconel X-750 tubing to serve as a wetting agent during brazing. Low-stress nickel-plating bath contains no organic wetting agents that cause the nickel to blister at high temperatures.

  2. Tectonics of oblique plate boundary systems

    NASA Astrophysics Data System (ADS)

    Díaz-Azpiroz, Manuel; Brune, Sascha; Leever, Karen A.; Fernández, Carlos; Czeck, Dyanna M.

    2016-12-01

    The relative displacement between lithospheric plates normally results in obliquely deforming plate boundaries. This is simply caused by the fact that, on plate tectonics basis, irregularly shaped plate boundaries are rarely perpendicular or parallel to small-circle rotation paths, which describe plate motion on a sphere (Fig. 1a). Global current relative plate motions estimated from geological data (DeMets et al., 2010; Argus et al., 2011) and GPS measurements (e.g., Kreemer et al., 2003; Argus et al., 2010) provide insight to the prevalent degrees of obliquity on Earth's surface. Based on these global data sets, Philippon and Corti (2016), statistically show that current orthogonal boundaries (obliquity angle smaller than 10°) represent around 8% of the total boundary length whereas strike-slip boundaries (obliquity angle larger than 80°) are encountered in < 10% of the total boundary length. Therefore, around 80% of active plate boundaries present oblique relative motions. Furthermore, changes in plate kinematics leading to migration or jumps in the rotation poles necessarily cause obliquity along former pure strike-slip or convergent/divergent boundaries (Fig. 1b).

  3. Evacuated flat-plate solar collectors

    SciTech Connect

    Whittemore, P.G.

    1981-09-15

    A structural support system is disclosed for use in an evacuated, flat-plate, solar collector to eliminate the problem of stress fractures in a glass cover plate. Nonlinearly spaced supports are used within the collector to dampen vibrations in the glass cover and to prevent overdeflection before buckling or stress fractures occur.

  4. Inverted flat plate solar collector. Final report

    SciTech Connect

    Brown, M.A.

    1981-08-26

    Construction and testing of an inverted flat plate solar collector are described. Heat transfer and economic analysis were performed to optimize the collector design. The newly designed collector was tested against two other flat plate collectors and the results and comparison of efficiencies are presented. (BCS)

  5. Fresnel diffraction plates are simple and inexpensive

    NASA Technical Reports Server (NTRS)

    Hoover, R. B.

    1967-01-01

    Fresnel plate demonstrates diffraction phenomena simply and inexpensively. A large number of identical diffracting apertures are made in random orientation on photographic film. When a small source of light is viewed through the plate, the diffraction pattern typical of the diffracting aperture is readily seen.

  6. Program sizes flange-tap orifice plate

    SciTech Connect

    Hogsett, J.E.

    1981-03-23

    A program developed for the TI-59 programmable calculator computes the differential pressure across an orifice, the gas flow through an orifice, or the orifice-plate bore for orifice plates with flange taps. Based on equations and data from L.K. Spinks, the program saves time in extracting from charts, tables, and graphs the values required to perform the calculations.

  7. Pressure-Letdown Plates for Coal Gasifiers

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1985-01-01

    Variation of pseudoporous plates used with coal gasifiers in pressure letdown stage of processing minimize clogging. Rotating plates containing variable gap annuli continually change flow path to enable erosionless reduction of gas pressure. Particles that otherwise clog porous plugs pass through gaps.

  8. Is There Really A North American Plate?

    NASA Astrophysics Data System (ADS)

    Krill, A.

    2011-12-01

    Lithospheric plates are typically identified from earthquake epicenters and evidence such as GPS movements. But no evidence indicates a plate boundary between the North American and South American Plates. Some plate maps show them separated by a transform boundary, but it is only a fracture zone. Other maps show an "undefined plate boundary" or put no boundary between these two plates (check Google images). Early plate maps showed a single large American Plate, quite narrow east of the Caribbean Plate (Le Pichon 1968, Morgan 1968). The North and South American Plates became established by the leading textbook Earth (Press & Siever 1974). On their map, from a Scientific American article by John Dewey (1972), these new plates were separated by an "uncertain plate boundary." The reasons for postulating a North American Plate were probably more psychological than geological. Each of the other continents of the world had its own plate, and North American geologists naturally wanted theirs. Similarly, European geographers used to view Europe as its own continent. A single large plate should again be hypothesized. But the term American Plate would now be ambiguous ("Which plate, North or South?") Perhaps future textbook authors could call it the "Two-American Plate." Textbook authors ultimately decide such global-tectonic matters. I became aware of textbook authors' opinions and influence from my research into the history of Alfred Wegener's continental drift (see Fixists vs. Mobilists by Krill 2011). Leading textbook author Charles Schuchert realized that continental drift would abolish his cherished paleogeographic models of large east-west continents (Eria, Gondwana) and small oceans (Poseiden, Nereis). He and his junior coauthors conspired to keep drift evidence out of their textbooks, from the 1934-editions until the 1969-editions (Physical Geology by Longwell et al. 1969, Historical Geology by Dunbar & Waage 1969). Their textbooks ruled in America. Textbooks

  9. Bending equation for a quasianisotropic plate

    NASA Astrophysics Data System (ADS)

    Shachnev, V. A.

    2010-10-01

    In the framework of the linear theory of elasticity, an exact bending equation is obtained for the median plane of a plate whose material is a monoclinic system with the axis of symmetry perpendicular to the plate plane. As an example, the equation of the median plane of an isotropic plate is considered; the operator of this equation coincides with the operator of Sophie Germain's approximate equation. As the plate thickness tends to zero, the right-hand side of the equation is asymptotically equivalent to the right-hand side of the approximate equation. In addition, equations relating the median plane transverse stresses and the total stresses in the plate boundary planes to the median plane deflexions are obtained.

  10. Thyroid hormone and the growth plate.

    PubMed

    Shao, Yvonne Y; Wang, Lai; Ballock, R Tracy

    2006-12-01

    Thyroid hormone was first identified as a potent regulator of skeletal maturation at the growth plate more than forty years ago. Since that time, many in vitro and in vivo studies have confirmed that thyroid hormone regulates the critical transition between cell proliferation and terminal differentiation in the growth plate, specifically the maturation of growth plate chondrocytes into hypertrophic cells. However these studies have neither identified the molecular mechanisms involved in the regulation of skeletal maturation by thyroid hormone, nor demonstrated how the systemic actions of thyroid hormone interface with the local regulatory milieu of the growth plate. This article will review our current understanding of the role of thyroid hormone in regulating the process of endochondral ossification at the growth plate, as well as what is currently known about the molecular mechanisms involved in this regulation.

  11. Cycloid kinematics of relative plate motion

    SciTech Connect

    Cronin, V.S.

    1987-11-01

    The trajectory of a point on one plate as observed from another plate is generally a complex curve and not a small circle around a single axis of relative motion, as is commonly assumed. The shape of the relative-motion path is given the general name spherical cycloid because of its morphological similarity to cycloid planetary trajectories described by early astronomers. The cycloid relative-motion model predicts that the following phenomena occur during finite displacements: (1) the relative velocity and the curvature of the trajectory of a point on one plate relative to another plate varies systematically; (2) plates wobble relative to one another; and (3) the angle of convergence and/or divergence varies systematically along the length of any given transform fault. The small-circle relative-motion model, whereby transform faults have been considered lines of pure slip along which crust is conserved, is not generally valid for finite relative displacements.

  12. AE Source Orientation by Plate Wave Analysis

    NASA Technical Reports Server (NTRS)

    Gorman, Michael R.; Prosser, William H.

    1991-01-01

    Lead breaks (Hsu-Neilsen source) were used to generate simulated acoustic emission signals in an aluminum plate at angles of 0, 30, 60, and 90 degrees with respect to the plane of the plate. This was accomplished by breaking the lead on slots cut into the plate at the respective angles. The out-of-plane and in-plane displacement components of the resulting signals were detected by broad band transducers and digitized. Analysis of the waveforms showed them to consist of the extensional and flexural plate modes. The amplitude of both components of the two modes was dependent on the source orientation angle. This suggests that plate wave analysis may be used to determine the source orientation of acoustic emission sources.

  13. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  14. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  15. Drag of wings with end plates

    NASA Technical Reports Server (NTRS)

    Hemke, Paul E

    1928-01-01

    In this report a formula for calculating the induced drag of multiplanes with end plates is derived. The frictional drag of the end plates are used, is sufficiently large to increase the efficiency of the wing. Curves showing the reduction of drag for monoplanes and biplanes are constructed; the influence of gap-chord ratio, aspect ratio, and height of end plate are determined for typical cases. The method of obtaining the reduction of drag for a multiplane is described. Comparisons are made of calculated and experimental results obtained in wind tunnel tests with airfoils of various aspect ratios and end plates of various sizes. The agreement between calculated and experimental results is good. Analysis of the experimental results shows that the shape and section of the end plates are important.

  16. Parallel Plate System for Collecting Data Used to Determine Viscosity

    NASA Technical Reports Server (NTRS)

    Kaukler, William (Inventor); Ethridge, Edwin C. (Inventor)

    2013-01-01

    A parallel-plate system collects data used to determine viscosity. A first plate is coupled to a translator so that the first plate can be moved along a first direction. A second plate has a pendulum device coupled thereto such that the second plate is suspended above and parallel to the first plate. The pendulum device constrains movement of the second plate to a second direction that is aligned with the first direction and is substantially parallel thereto. A force measuring device is coupled to the second plate for measuring force along the second direction caused by movement of the second plate.

  17. Piezoactuation of sandwich plates with viscoelastic cores

    NASA Astrophysics Data System (ADS)

    Wang, Gang; Wereley, Norman M.

    1999-06-01

    Experimental and analytical validations of a Galerkin analysis of sandwich plates is presented in this paper. The 3-layered sandwich plate specimen consists of isotropic face-plates with surface bonded piezo-electric patch actuators, and a viscoelastic core. The experimental validation is conducted by testing sandwiched plates that are 67.31 cm (26.5') long, 52.07 cm (20.5') wide and nominally 0.16 cm (1/16') thick. The analysis includes the membrane and transverse energies in the face plates, and shear energies in the core. The shear modulus of the dissipative core is assumed to be complex and variant with frequency and temperature. The Golla-Hughes-McTavish (GHM) method is used to account for the frequency dependent properties of the viscoelastic core. Experiments have been conducted on sandwich plates with aluminum face-plates under clamped boundary conditions to validate the model for isotropic face-plates. Symmetric and asymmetric sandwiches have been tested. The maximum error in damped natural frequency predictions obtained via the assumed modes solutions is less than 11%. Analytical studies on the influence of the number of assumed modes in the Galerkin approximation, and the temperature variation, have been conducted. Error in the first plate bending mode is 112% when only a single in-plane mode is used; error reduces to 3.95% as the number of in-plane modes is increased to 25 in each of the in-plane directions. The study on the temperature influence shows that every plate mode has a corresponding temperature, wherein the loss factor is maximized.

  18. Tectonic Evolution of the Jurassic Pacific Plate

    NASA Astrophysics Data System (ADS)

    Nakanishi, M.; Ishihara, T.

    2015-12-01

    We present the tectonic evolution of the Jurassic Pacific plate based on magnetic anomly lineations and abyssal hills. The Pacific plate is the largest oceanic plate on Earth. It was born as a microplate aroud the Izanagi-Farallon-Phoenix triple junction about 192 Ma, Early Jurassic [Nakanishi et al., 1992]. The size of the Pacific plate at 190 Ma was nearly half that of the present Easter or Juan Fernandez microplates in the East Pacific Rise [Martinez et at, 1991; Larson et al., 1992]. The plate boundary surrounding the Pacific plate from Early Jurassic to Early Cretaceous involved the four triple junctions among Pacific, Izanagi, Farallon, and Phoenix plates. The major tectonic events as the formation of oceanic plateaus and microplates during the period occurred in the vicinity of the triple junctions [e.g., Nakanishi and Winterer, 1998; Nakanishi et al., 1999], implying that the study of the triple junctions is indispensable for understanding the tectonic evolution of the Pacific plate. Previous studies indicate instability of the configuration of the triple junctions from Late Jurassic to Early Cretaceous (155-125 Ma). On the other hand, the age of the birth of the Pacific plate was determined assuming that all triple junctions had kept their configurations for about 30 m.y. [Nakanishi et al., 1992] because of insufficient information of the tectonic history of the Pacific plate before Late Jurassic.Increase in the bathymetric and geomagnetic data over the past two decades enables us to reveal the tectonic evolution of the Pacific-Izanagi-Farallon triple junction before Late Jurassic. Our detailed identication of magnetic anomaly lineations exposes magnetic bights before anomaly M25. We found the curved abyssal hills originated near the triple junction, which trend is parallel to magnetic anomaly lineations. These results imply that the configuration of the Pacific-Izanagi-Farallon triple junction had been RRR before Late Jurassic.

  19. Voltage-current characteristics of a pin-plate system with different plate configurations

    NASA Astrophysics Data System (ADS)

    Feng, Zhuangbo; Long, Zhengwei

    2013-03-01

    In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.

  20. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  1. On the Origin of Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Bercovici, D.

    2014-12-01

    The emergence of plate tectonics was Earth's defining moment. How and when platetectonics started is shrouded in mystery because of the paucity of observations in theArchean as well the challenge of understanding how plates are generated. The damage theoryof lithospheric weakening by grain-reduction provides a physical framework for plategeneration. This model builds on grain-scale processes to elucidate planetary-scaletectonics, and is consistent with lab and field observations of polycrystalline rocks andlithospheric shear zones. The grain-damage model accounts for the evolution of damage andhealing (by grain growth) at various planetary conditions, hence predicts plate boundaryformation and longevity, and how they depend on surface environment. For example, the onset of prototectonics is predicted to require clement conditions tokeep healing from erasing weak zones; conversely, cool conditions possibly requiredtectonics to draw down primordial CO2. Thus whether tectonics preceded a cool climate (andwater) or vice versa is immaterial as they likely needed each other or neither wouldexist. Sparse evidence that prototectonics co-initiated with liquid water hints at thelink between tectonics, water and surface conditions. The establishment of wide-spread plate tectonics started between >4Ga and 2.7Ga, and mayhave taken over a billion years to develop. Under Earth-like conditions, combininggrain-damage with intermittent Archean protosubduction produces persistent weak zones thataccumulate to yield well developed plates within 1Gyrs. In contrast, Venus' hottersurface conditions promotes healing and prohibits weak zone accumulation, which explainswhy plate tectonics failed to spread on our sister planet. Damage and weak-zone inheritance may also influence plate evolution and reorganization inthe modern era. Changes in plate direction, such as reflected in the Emperor-Hawaiianbend, leave weak zones misaligned with plate motion, causing oblique plate boundaries

  2. An updated digital model of plate boundaries

    NASA Astrophysics Data System (ADS)

    Bird, Peter

    2003-03-01

    A global set of present plate boundaries on the Earth is presented in digital form. Most come from sources in the literature. A few boundaries are newly interpreted from topography, volcanism, and/or seismicity, taking into account relative plate velocities from magnetic anomalies, moment tensor solutions, and/or geodesy. In addition to the 14 large plates whose motion was described by the NUVEL-1A poles (Africa, Antarctica, Arabia, Australia, Caribbean, Cocos, Eurasia, India, Juan de Fuca, Nazca, North America, Pacific, Philippine Sea, South America), model PB2002 includes 38 small plates (Okhotsk, Amur, Yangtze, Okinawa, Sunda, Burma, Molucca Sea, Banda Sea, Timor, Birds Head, Maoke, Caroline, Mariana, North Bismarck, Manus, South Bismarck, Solomon Sea, Woodlark, New Hebrides, Conway Reef, Balmoral Reef, Futuna, Niuafo'ou, Tonga, Kermadec, Rivera, Galapagos, Easter, Juan Fernandez, Panama, North Andes, Altiplano, Shetland, Scotia, Sandwich, Aegean Sea, Anatolia, Somalia), for a total of 52 plates. No attempt is made to divide the Alps-Persia-Tibet mountain belt, the Philippine Islands, the Peruvian Andes, the Sierras Pampeanas, or the California-Nevada zone of dextral transtension into plates; instead, they are designated as "orogens" in which this plate model is not expected to be accurate. The cumulative-number/area distribution for this model follows a power law for plates with areas between 0.002 and 1 steradian. Departure from this scaling at the small-plate end suggests that future work is very likely to define more very small plates within the orogens. The model is presented in four digital files: a set of plate boundary segments; a set of plate outlines; a set of outlines of the orogens; and a table of characteristics of each digitization step along plate boundaries, including estimated relative velocity vector and classification into one of 7 types (continental convergence zone, continental transform fault, continental rift, oceanic spreading ridge

  3. Reducing chromium losses from a chromium plating bath. 1987 summer intern report. Project conducted at New Dimension Plating, Hutchinson, Minnesota

    SciTech Connect

    Achman, D.

    1987-12-31

    The company employs about forty people and operates for one or two eight hour shifts with an average of 315 racks of chrome plating per eight hour day. They plate a variety of metals including copper, nickel, gold, brass and chromium. Chromium is the major metal plated and is usually the last step in plating cycle. Most parts are copper plated and then nickel plated in preparation for chrome plating. The main difference between New Dimension Plating and other plating shops is the variety of parts plated. As New Dimension Plating is a job shop, a wide range of parts such as motorcycle accessories, stove parts, and custom items are metal finished. The plating lines are manual, meaning employees dip the racks into the tanks by hand. This fact along with the fact that parts vary greatly in size and shape accounts for the significant drag-out on the chromium plating line.

  4. Self-Aspirated Atmospheric Pressure Chemical Ionization Source for Direct Sampling of Analytes on Surfaces and in Liquid Solutions

    SciTech Connect

    Asano, Keiji G; Ford, Michael J; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    A self-aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self-aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed-phase thin-layer chromatography plate in which a three-component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full-scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol(reg. sign) and Evista(reg. sign) tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384-well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine-d{sub 3} as an internal standard.

  5. Thermal Casimir interaction between two magnetodielectric plates

    SciTech Connect

    Geyer, B.; Klimchitskaya, G. L.; Mostepanenko, V. M.

    2010-03-01

    We investigate the thermal Casimir interaction between two magnetodielectric plates made of real materials. On the basis of the Lifshitz theory, it is shown that for diamagnets and for paramagnets in the broad sense (with exception of ferromagnets) the magnetic properties do not influence the magnitude of the Casimir force. For ferromagnets, taking into account the realistic dependence of magnetic permeability on frequency, we conclude that the impact of magnetic properties on the Casimir interaction arises entirely from the contribution of the zero-frequency term in the Lifshitz formula. The computations of the Casimir free energy and pressure are performed for the configurations of two plates made of ferromagnetic metals (Co and Fe), for one plate made of ferromagnetic metal and the other of nonmagnetic metal (Au), for two ferromagnetic dielectric plates (on the basis of polystyrene), and for a ferromagnetic dielectric plate near a nonmagnetic metal plate. The dielectric permittivity of metals is described using both the Drude and the plasma model approaches. It is shown that the Casimir repulsion through the vacuum gap can be realized in the configuration of a ferromagnetic dielectric plate near a nonmagnetic metal plate described by the plasma model. In all cases considered, the respective analytical results in the asymptotic limit of large separations between the plates are obtained. The impact of the magnetic phase transition through the Curie temperature on the Casimir interaction is considered. In conclusion, we propose several experiments allowing to determine whether the magnetic properties really influence the Casimir interaction and to independently verify the Drude and plasma model approaches to the thermal Casimir force.

  6. Laminated anisotropic reinforced plastic plates and shells

    NASA Technical Reports Server (NTRS)

    Korolev, V. I.

    1981-01-01

    Basic technical theories and engineering calculation equations for anisotropic plates and shells made of rigid reinforced plastics, mainly laminated fiberglass, are presented and discussed. Solutions are given for many problems of design of structural plates and shells, including curved sections and tanks, as well as two chapters on selection of the optimum materials, are given. Accounting for interlayer shearing and transverse separation, which are new engineering properties, are discussed. Application of the results obtained to thin three ply plates and shells wth a light elastic filler is presented and discussed.

  7. Natural frequencies of twisted rotating plates

    NASA Astrophysics Data System (ADS)

    Ramamurti, V.; Kielb, R.

    1984-12-01

    A detailed comparison is presented of the predicted eigenfrequencies of twisted rotating plates as obtained by using two different shape functions. Primarily, rotating twisted plates of two different aspect ratios and two different thickness ratios are considered. The effects of rotation are included by using a "stress smoothing" technique when calculating the augmented stiffness matrix. In addition, the effects of Coriolis acceleration, contributions from membrane behaviour, setting angle and sweep angle are considered. The effects of geometric non-linearity are briefly discussed. Finally, results of a brief study of cambered plates are presented.

  8. Natural frequencies of twisted rotating plates

    NASA Technical Reports Server (NTRS)

    Ramamurti, V.; Kielb, R.

    1984-01-01

    A detailed comparison is presented of the predicted eigenfrequencies of twisted rotating plates as obtained by using two different shape functions. Primarily, rotating twisted plates of two different aspect ratios and two different thickness ratios are considered. The effects of rotation are included by using a 'stress smoothing' technique when calculating the augmented stiffness matrix. In addition, the effects of Coriolis acceleration, contributions from membrane behavior, setting angle and sweep angle are considered. The effects of geometric nonlinearity are briefly discussed. Finally, results of a brief study of cambered plates are presented.

  9. Research Investigation of Armor Plate Steels

    DTIC Science & Technology

    1942-02-20

    location at which the ballistic limits were determined. Ballistic limits and average hardness values from the 16 duplicate plates are given in Table 10 ...OF ARMOR PLATE STEELS Plate Nuzuber %C %.Mn %Si %Ni. %Cr %Mo %cu *7111 .46 1.58 .20 . 10 /.20 7276 .50 1.07 .3o 7277 .39 .35 .23 7278 .47 .91 .26 7279...26 2.3/2.7 7328 .34 .89 .20 1.3/1.7 .35/.46 * 7329 .34 .88 .25 1.3/1.7 10 /.20 7330 .46 .86 .24 .25/.35 : 10 /.20 734 .46 .84 .29 W 5. 35 7341 .34 .94

  10. Problem of Electromagnetoviscoelasticity for Multiply Connected Plates

    NASA Astrophysics Data System (ADS)

    Kaloerov, S. A.; Samodurov, A. A.

    2015-11-01

    A method for solving the problem of electromagnetoviscoelasticity for multiply connected plates is proposed. The small-parameter method is used to reduce this problem to a recursive sequence of problems of electromagnetoelasticity, which are solved by using complex potentials. A procedure is developed to determine, using complex potentials, approximations of the basic characteristics (stresses, electromagnetic-field strength, electromagnetic-flux density) of the electromagnetoelastic state at any time after application of a load. A plate with an elliptic hole is considered as an example. The variation in the electromagnetoelastic state of the multiply connected plate with time is studied

  11. Effusion plate using additive manufacturing methods

    DOEpatents

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  12. Bi-coolant flat plate solar collector

    NASA Astrophysics Data System (ADS)

    Chon, W. Y.; Green, L. L.

    The feasibility study of a flat plate solar collector which heats air and water concurrently or separately was carried out. Air flows above the collector absorber plate, while water flows in tubes soldered or brazed beneath the plate. The collector efficiencies computed for the flow of both air and water are compared with those for the flow of a single coolant. The results show that the bi-coolant collector efficiency computed for the entire year in Buffalo, New York is higher than the single-coolant collector efficiency, although the efficiency of the water collector is higher during the warmer months.

  13. Seismic anisotropy above a subducting plate

    SciTech Connect

    Shih, X.R.; Meyer, R.P. ); Schneider, J.F. )

    1991-08-01

    Shear-wave splitting observed in northeastern Colombia has provided evidence of seismic anisotropy in a shear zone immediately above a subducting plate. In an upper mantle composed mainly of olivine (57%) and orthopyroxene (17%), the splitting can be interpreted by wave propagation in an anisotropic medium of orthorhombic symmetry that results from alignment of these intrinsically anisotropic minerals. The mechanism of alignment is most likely the shearing associated with the subduction, aided by fluids migrating from the subducting plate when the plate exceeds 100 km in depth.

  14. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  15. Treasure-Hunting in Astronomical Plate Archives

    NASA Astrophysics Data System (ADS)

    Kroll, Peter; La Dous, Constanze; Bräuer, Hans-Jürgen

    In our days astronomical research shows two trends - anong others: On the one hand traditional astronomical plate archives are in danger of falling into oblivion while science is losing their information content. On the other hand, there is an ever-growing need for long-term monitoring of large quantities of objects - the very information contained in the archives. On thes background the workshop ``Treasure-Hunting in Astronomical Plate Archives'' was convened in order to discuss the scientific potential of the world's photometric and astrometric plate archives, ways of making them fully available to scientific research, as well as technical problems connected with this.

  16. Ion plating with an induction heating source

    NASA Technical Reports Server (NTRS)

    Spalvins, T.; Brainard, W. A.

    1976-01-01

    Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

  17. Transpiration effects in perforated plate aerodynamics

    NASA Astrophysics Data System (ADS)

    Szwaba, R.; Ochrymiuk, T.

    2016-10-01

    Perforated walls find a wide use as a method of flow control and effusive cooling. Experimental investigations of the gas flow past perforated plate with microholes (110μm) were carried out. The wide range of pressure at the inlet were investigated. Two distinguishable flow regimes were obtained: laminar and turbulent regime.The results are in good agreement with theory, simulations and experiments on large scale perforated plates and compressible flows in microtubules. Formulation of the transpiration law was associated with the porous plate aerodynamics properties. Using a model of transpiration flow the “aerodynamic porosity” could be determined for microholes.

  18. Electrochemical Machining of Metal Plates

    SciTech Connect

    Cooper, J F; Evans, M C

    2005-03-04

    Electrochemical machining (ECM) with concentrated sodium chlorate electrolyte was used to rapidly cut a circular groove (13 cm diameter, 0.2 cm wide) through a 0.15 cm thick sheet of steel--thus opening a 5-inch porthole in as little as 10 minutes. The most favorable operating conditions were: T = 22 C; chlorate concentration 600 g NaClO{sub 3}/liter-solution; electric power of 100 A at 10 V; and flow of 0.5 l/s at a pressure drop of 10 kPa (1.5 psi). The porthole may be removed entirely by electrochemical means, or the electrochemical dissolution may continue until only thin membrane remains that is subsequently cut with a utility knife. An array of thermocouples was used to track temperature in the flowing solution and in the trough being machined; the maximum increase in temperature in the trough was 5 C over that of the flowing electrolyte which increased in temperature by 19 C because of power dissipation. ECM is shown feasible for rapid perforation of plates of ferrous and non-ferrous metals using portable equipment and commercial batteries. The technique can be extended to cut perforations of arbitrary shape through non-planar surfaces using a deformable ring cathode. Analysis of the power requirements for electrolyte flow and ECM indicate a total system weight of less than 45 kg (100 lb) using a commercial NiMH battery. The technique is recommended for reduction to practice and demonstration on full scale as an engineering prototype.

  19. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    PubMed

    Hernigou, Philippe; Pariat, Jacques

    2016-12-30

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  20. Dynamic Stabilization of Simple Fractures With Active Plates Delivers Stronger Healing Than Conventional Compression Plating

    PubMed Central

    Tsai, Stanley; Bliven, Emily K.; von Rechenberg, Brigitte; Kindt, Philipp; Augat, Peter; Henschel, Julia; Fitzpatrick, Daniel C.; Madey, Steven M.

    2017-01-01

    Objectives: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. Methods: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. Results: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. Conclusions: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing. PMID:27861456

  1. Two new plate nozzles for the production of alginate microspheres.

    PubMed

    Yang, Fan; Wang, Kang; He, Zhimin

    2005-07-14

    Combining the Rayleigh-type jet break-up and two new plate nozzles, the alginate microsphere was produced. Spray generators made of syringe needle and laser-drilling nozzle plate and synthetic red stone nozzle plate were fabricated and contrasted. The above two plate nozzles provided lower liquid resistance and yield well. Furthermore, the more uniform microsphere was produced within a wider range of frequency by plate nozzles. Experiments using multiple-nozzle synthetic red stone plate was easy to feasible.

  2. Compressive strength of damaged and repaired composite plates

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1992-01-01

    Tests were performed assessing the effectiveness of repair in restoring the mechanical properties of damaged, solid composite plates made of Fiberite T300/976 graphite-epoxy. Some (75%) or all (100%) of the damaged zone was cut out, and the plate was repaired by plugging and patching the hole. The effectiveness of the repair was evaluated by measuring the compressive strengths of undamaged plates, damaged plates with no cutout, damaged plates with a cutout, and plates that had been repaired.

  3. Thermo-mechanical buckling analysis of FGM plate using generalized plate theory

    NASA Astrophysics Data System (ADS)

    Sharma, Kanishk; Kumar, Dinesh; Gite, Anil

    2016-05-01

    This paper investigates the thermo-mechanical buckling behavior of simply-supported FGM plate under the framework of generalized plate theory (GPT), which includes classical plate theory (CPT), first order shear deformation theory (FSDT) and higher order shear deformation theory (HSDT) as special cases. The governing equations for FGM plate under thermal and mechanical loading conditions are derived from the principle of virtual displacements and Navier-type solution is assumed for simply supported boundary condition. The efficiency and applicability of presented methodology is illustrated by considering various examples of thermal and mechanical buckling of FGM plates. The closed form solutions in the form of critical thermal and mechanical buckling loads, predicted by CPT, FSDT and HSDT are compared for different side-to-thickness of FGM plate. Subsequently, the effect of material gradation profile on critical buckling parameters is examined by evaluating the buckling response for a range of power law indexes. The effect of geometrical parameters on mechanical buckling of FGM plate under uni-axial and bi-axial loading conditions are also illustrated by calculating the critical load for various values of slenderness ratios. Furthermore a comparative analysis of critical thermal buckling loads of FGM plate for different temperature profiles is also presented. It is identified that all plate theories predicted approximately same critical buckling loads and critical buckling temperatures for thin FGM plate, however for thick FGM plates, CPT overestimates the critical buckling parameters. Moreover the critical buckling loads and critical buckling temperatures of FGM plate are found to be significantly lower than the corresponding homogenous isotropic ceramic plate (n=0).

  4. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Electrical Electrical Installations Operating at Potentials of Less Than 50 Volts on Vessels of Less Than 100... provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  5. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Electrical Electrical Installations Operating at Potentials of Less Than 50 Volts on Vessels of Less Than 100... provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  6. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Electrical Electrical Installations Operating at Potentials of Less Than 50 Volts on Vessels of Less Than 100... provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  7. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Electrical Electrical Installations Operating at Potentials of Less Than 50 Volts on Vessels of Less Than 100... provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  8. Characterization of Tri-lab Tantalum Plate.

    SciTech Connect

    Buchheit, Thomas E.; Cerreta, Ellen K.; Deibler, Lisa Anne; Chen, Shu-Rong; Michael, Joseph R.

    2014-09-01

    This report provides a detailed characterization Tri-lab Tantalum (Ta) plate jointly purchased from HCStark Inc. by Sandia, Los Alamos and Lawrence Livermore National Laboratories. Data in this report was compiled from series of material and properties characterization experiments carried out at Sandia (SNL) and Los Alamos (LANL) Laboratories through a leveraged effort funded by the C2 campaign. Results include microstructure characterization detailing the crystallographic texture of the material and an increase in grain size near the end of the rolled plate. Mechanical properties evaluations include, compression cylinder, sub-scale tension specimen, micohardness and instrumented indentation testing. The plate was found to have vastly superior uniformity when compare with previously characterized wrought Ta material. Small but measurable variations in microstructure and properties were noted at the end, and at the top and bottom edges of the plate.

  9. Earth science: Plate motion and mantle plumes

    NASA Astrophysics Data System (ADS)

    Müller, R. Dietmar

    2011-07-01

    A model based on geophysical data from the Indian Ocean suggests that a mantle-plume head may once have coupled the motions of the African and Indian tectonic plates, and determined their respective speeds. See Article p.47

  10. Coloured Rings Produced on Transparent Plates

    ERIC Educational Resources Information Center

    Suhr, Wilfried; Schlichting, H. Joachim

    2007-01-01

    Beautiful colored interference rings can be produced by using transparent plates such as window glass. A simple model explains this effect, which was described by Newton but has almost been forgotten. (Contains 11 figures.)

  11. Polar Plate Theory for Orthogonal Anisotropy

    NASA Technical Reports Server (NTRS)

    Bailey, Michelle D.; Bower, Mark V.

    2000-01-01

    Laminated fiber-reinforced (or filamentary) composites are used today for their high strength-to-weight and stiffness-to-weight ratios. However, because of the anisotropic behavior of composites, determining the response on a macroscopic scale is challenging. This is particularly evident in the evaluation of the governing differential equations of a circular disk with the fibers of the lamina oriented with rectilinear orthogonality. This includes any situation involving a composite plate of circular geometry in which out-of-plane displacements due to load are desired, such as fastener pull through loading of a composite plate. Current analysis techniques use numerical methods with rectilinear coordinate systems to solve problems with circular geometry. These analyses over predict plate stiffness by 20% and underpredict failure by 70%. Consequently, there is a need to transform classical composite plate theory to a polar coordinate system. In order to better analyze structures with circular geometries the classical composite plate equations are transformed into the plate equations for a rectilinearly anisotropic composite in polar coordinates. A composite plate is typically a laminate of fibers in rectilinear directions. Subsequent to the lay-tip the necessary geometry is cut out of a rectangular plate. In a similar manner, the derivation of the plate equation starts with the fundamental definitions of strain, displacement and curvature and incorporates the material property angular dependence into the equilibrium equations for a differential polar element. In the transformed state, the stiffness coefficients are no longer constant, adding to the complexity of the governing differential equations. This paper discusses the new derivation and evaluation of the plate equations for a circular composite disk with orthogonal rectilinear anisotropy. The resultant new three partial differential equations, which describe the circular anisotropic plate, can be used to

  12. Remediation System Evaluation, Peerless Plating Site

    EPA Pesticide Factsheets

    The Peerless Plating Superfund Site is located at 2554 South Getty Street, north of the intersection of South Getty Street and East Sherman Boulevard in Muskegon, Michigan. Copper, nickel, chromium, cadmium, and zinc electroplating operations as well as...

  13. Transient Sound Radiation from Infinite Thin Plate,

    DTIC Science & Technology

    1987-08-01

    displacement is assumed to satisfy the thin plate theory of Sophie Germain , viz. Da21ar2+(l/r)a/8rJ2 W(r,t)+M8 2W(r,t)/at 2 = F(r,t)-p(r,O,t) (2.1) where D=Eh3...only for Sophie Germain plate theory. For Timoshenko-Mindlin plate theory G(x0 ,w) = EC(Dc2-ph 3 w2 /12)(m 2 -pW 2 /KG)-phw2)/ (l+Do2 /KGh-psh 2W2/12KG...include any proprietary software. Both Sophie Germain and Timoshenko-Mindlin plate theories are included in the program as options, and ’exact’ linear

  14. The Continental Plates are Getting Thicker.

    ERIC Educational Resources Information Center

    Kerr, Richard A.

    1986-01-01

    Reviews seismological studies that provide evidence of the existence of continental roots beneath the continents. Suggests, that through the collisions of plate tectonics, continents stabilized part of the mobile mantle rock beneath them to form deep roots. (ML)

  15. Hardfacing and wear plates battle abrasion

    SciTech Connect

    Miller, R.F.

    1983-06-01

    This article examines abrasion-resistant steels and hardfacing as two effective weapons at the disposal of material handlers. It points out that abrasion is probably the single most destructive form of wear in the mixing and processing of coal. Particulate matter such as quartz sand and other minerals including coal curtail in-service life of dragline buckets, chute, crusher rolls, gates and valves, exhauster fan blades, target plates, truck beds, hoppers, vibrating pans, grinding mills, piping elbows, etc. The advantages of abrasion-resistant steels and hardfacing can be obtained in the form of a composite wear plate-hardfacing on a carbon steel backup plate. It concludes that the composite wear plate represents a major innovation since its advantages include ease of handling, low cost and easy installation, minimum on-site welding time and versatility. Its use is limited only to the consumer's creativity in application.

  16. Transient response of a laminated composite plate

    NASA Technical Reports Server (NTRS)

    Datta, S. K.; Ju, T. H.; Bratton, R. L.; Shah, A. H.

    1992-01-01

    Results are presented from an investigation of the effect of layering on transient wave propagation in a laminated cross-ply plate, giving attention to the case of 2D plane strain in the case where a line vertical force is applied on a free surface of the plate; the line may be either parallel or perpendicular to the fibers in a ply. The results are in both the time and frequency domains for the normal stress component in the x direction, at a point on the surface of the plate on which the force is applied. Comparative results are also presented for a homogeneous plate whose properties are the static effective ones, when the number of plies is large.

  17. Theoretical analysis of impact in composite plates

    NASA Technical Reports Server (NTRS)

    Moon, F. C.

    1973-01-01

    The calculated stresses and displacements induced anisotropic plates by short duration impact forces are presented. The theoretical model attempts to model the response of fiber composite turbine fan blades to impact by foreign objects such as stones and hailstones. In this model the determination of the impact force uses the Hertz impact theory. The plate response treats the laminated blade as an equivalent anisotropic material using a form of Mindlin's theory for crystal plates. The analysis makes use of a computational tool called the fast Fourier transform. Results are presented in the form of stress contour plots in the plane of the plate for various times after impact. Examination of the maximum stresses due to impact versus ply layup angle reveals that the + or - 15 deg layup angle gives lower flexural stresses than 0 deg, + or - 30 deg and + or - 45 deg. cases.

  18. Aeroheating model advancements featuring electroless metallic plating

    NASA Technical Reports Server (NTRS)

    Stalmach, C. J., Jr.; Goodrich, W. D.

    1976-01-01

    Discussed are advancements in wind tunnel model construction methods and hypersonic test data demonstrating the methods. The general objective was to develop model fabrication methods for improved heat transfer measuring capability at less model cost. A plated slab model approach was evaluated with cast models containing constantan wires that formed single-wire-to-plate surface thermocouple junctions with a seamless skin of electroless nickel alloy. The surface of a space shuttle orbiter model was selectively plated with scaled tiles to simulate, with high fidelity, the probable misalignments of the heatshield tiles on a flight vehicle. Initial, Mach 8 heating results indicated a minor effect of tile misalignment roughness on boundary layer transition, implying a possible relaxation of heatshield manufacturing tolerances. Some loss of the plated tiles was experienced when the model was tested at high heating rates.

  19. High efficiency flat plate solar energy collector

    SciTech Connect

    Butler, R. F.

    1985-04-30

    A concentrating flat plate collector for the high efficiency collection of solar energy. Through an arrangement of reflector elements, incoming solar radiation, either directly or after reflection from the reflector elements, impinges upon both surfaces of a collector element.

  20. Vibro-acoustic analysis of composite plates

    NASA Astrophysics Data System (ADS)

    Sarigül, A. S.; Karagözlü, E.

    2014-03-01

    Vibro-acoustic analysis plays a vital role on the design of aircrafts, spacecrafts, land vehicles and ships produced from thin plates backed by closed cavities, with regard to human health and living comfort. For this type of structures, it is required a coupled solution that takes into account structural-acoustic interaction which is crucial for sensitive solutions. In this study, coupled vibro-acoustic analyses of plates produced from composite materials have been performed by using finite element analysis software. The study has been carried out for E-glass/Epoxy, Kevlar/Epoxy and Carbon/Epoxy plates with different ply angles and numbers of ply. The effects of composite material, ply orientation and number of layer on coupled vibro-acoustic characteristics of plates have been analysed for various combinations. The analysis results have been statistically examined and assessed.

  1. Method for plating with metal oxides

    SciTech Connect

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  2. Method for plating with metal oxides

    SciTech Connect

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  3. Reconstructing Plate Motions on Europa with GPlates

    NASA Astrophysics Data System (ADS)

    Cutler, B. B.; Collins, G. C.; Prockter, L. M.; Patterson, G.; Kattenhorn, S. A.; Rhoden, A.; Cooper, C. M.

    2015-12-01

    Observations of past plate tectonic - like motions in Europa's icy lithosphere have been reported in previous studies. Quantifying the nature, age, and amount of plate motion is important for geophysical models of Europa's ice shell and for astrobiology, since subsumed pates could drive the flow of nutrients into the subsurface ocean. We have used GPlates software (Williams et al., GSA Today 2012) and a mosaic of regional-resolution Galileo SSI data from orbits E11, E15, E17, and E19 to make interactive reconstructions of both the Northern Falga region (60N, 220W) and the Castalia Macula region (0N, 225W). The advantage of this method is that plate motions are calculated on a sphere, while still maintaining the original Galileo image pieces in their proper geographic locations. Previous work on the Castalia Macula region (Patterson et al. J.Struct.Geol. 2006) and the adjacent Phaidra Linea region (Patterson and Ernst, LPSC 2011) found offsets along spreading boundaries, and then calculated the best fit finite rotations to close those offsets. Though this method is mathematically rigorous and gives a statistical goodness of fit, it is not easy to test multiple hypotheses for candidate piercing points or divisions of candidate plate boundaries. Through the interactive environment, we found that we could better account for observed offsets in this region by breaking it into 32 different plates. Patterson and Ernst broke the Phaidra region into 6 plates which exhibited nonrigid behavior, where our study breaks it into 16 rigid plates. The Northern Falga Regio area is interesting due to the potential for large amounts of subsumption of Europa's icy crust in this location. The previous reconstruction (Kattenhorn and Prockter, Nat.Geosci. 2014) was based on planar geometry, and we have replicated these results using a spherically-based reconstruction. We will present the plate maps and reconstructions for both of these regions, along with the best fit rotation poles.

  4. Composite bipolar plate for electrochemical cells

    DOEpatents

    Wilson, Mahlon S.; Busick, Deanna N.

    2001-01-01

    A bipolar separator plate for fuel cells consists of a molded mixture of a vinyl ester resin and graphite powder. The plate serves as a current collector and may contain fluid flow fields for the distribution of reactant gases. The material is inexpensive, electrically conductive, lightweight, strong, corrosion resistant, easily mass produced, and relatively impermeable to hydrogen gas. The addition of certain fiber reinforcements and other additives can improve the properties of the composite material without significantly increasing its overall cost.

  5. Liquid repellency by a moving plate

    NASA Astrophysics Data System (ADS)

    Bouillant, Ambre; Anais Gauthier Team; David Quere Team; Christophe Clanet Team

    2016-11-01

    Moving solids can repel impacting drops, owing to their motion. Provided the solid velocity is larger than a threshold value, air entrained at the vicinity of the moving plate prevents the drop from wetting, and makes it bounce. In addition, the rebound is oblique, which enhances the evacuation of liquid. We discuss experiments and models on this theme, and extend them to case of small droplets (such as formed in a spray) found to be even more efficiently repelled by the moving plate.

  6. Tomography, the geoid and plate motions

    NASA Technical Reports Server (NTRS)

    Gable, Carl W.; O'Connell, Richard J.

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period.

  7. Lighting system with heat distribution face plate

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  8. Plate Tectonics, Geographical Information System, paleogeography

    SciTech Connect

    Moore, Thomas L.; Scotese, Christopher

    2002-05-24

    The PaleoX.framwork is a dynamically linked/loaded framework for Cocoa applications. The primary goal of this library is to standardize several elements used for working with paleogeographic data. This includes objects designed to organize information for tectonic plates, including maps, rotation objects, plate names, and designations. In addition, PaleoX provides object-oriented solutions for handling standard paleogeographic file formats from the PALEOMAP Project.

  9. Designing Bolted Joints Between Composite Plates

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    1994-01-01

    Simplified methods developed for use in preliminary design and analysis of bolted joints between flat composite-material plates loaded in tension. Analysis also applicable to joints between composite and metal plates. Methods based on approximate equations for limiting stresses in single-bolt joint in five modes of failure: local-bearing-failure, net tension, wedge-type splitting, shear-out, and tension with shear-out.

  10. Microchannel Plate Imaging Detectors for the Ultraviolet

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Gummin, M. A.; Stock, J.; Marsh, D.

    1992-01-01

    There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

  11. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  12. Optimization of modified volume Fresnel zone plates.

    PubMed

    Srisungsitthisunti, Pornsak; Ersoy, Okan K; Xu, Xianfan

    2009-10-01

    Modified volume Fresnel zone plates (MVFZPs) fabricated with laser direct writing were optimized for higher diffraction efficiencies. The Fresnel radii in each layer of a volume zone plate were iteratively adjusted by a simulation-based direct search optimization. The results show that optimization is effective but depends strongly on the starting diffraction efficiencies determined by the MVFZP parameters. The simulations indicate that the optimized MVFZP can achieve 93% diffraction efficiency.

  13. Plated-through hole testing. Final repot

    SciTech Connect

    Abel, W.B.

    1980-05-01

    An improved microresistance testing method to measure the thickness of copper plating in plated-through holes of double-sided printed wiring boards is presented. A new probe design, combined with a microprocessor controller, makes it possible for a direct reading tester to provide variables data. Tester design and software programs for the system are included. Results of correlation studies, comparing the improved resistance method to cross-sectional measurements are presented. Limitations on the microresistance test method are discussed.

  14. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-01-01

    A fuel cell includes a separator plate having first and second flow channels extending therethrough contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are suplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material.

  15. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-10-02

    A fuel cell includes a separator plate having first and second flow channels extending there through contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are supplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material. 10 figs.

  16. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    PubMed

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.

  17. Photodynamic impact on the epiphyseal plates.

    PubMed

    Kurchenko, S; Shashko, A; Dudin, M; Mikhailov, V; Netylko, G; Ashmarov, V

    2012-01-01

    This study was carried out to prove the possibility of inhibition of long bones epiphyseal plates activity with photodynamic impact. Comparative analysis of the Chlorin E6 accumulation with transcutaneous and intraperitoneal administration mode, carried out on 175 laboratory mice showed the drug accumulates selectively in the epiphyseal plates of long bones, regardless of the mode of administration. 15 mice (males and females) at the age of active grownig were subjected to the single laser radiation impact on the knee joints area: 5 ones with transcutaneous Chlorine E6 administration, another 5 ones with intraperitoneal administration and the rest 5 without the drug. Histological samples of 15 experimental mice epiphyseal plates were examined by light microscopy, compared with 10 intact control mice. Influence of the laser radiation without administration of Chlorin E6 leads to intracellular swelling of epiphyseal plates chondrocytes. Influence of the laser radiation after transcutaneous or intraperitoneal injection of Chlorine E6 reduces significantly the total number of epiphyseal plates chondrocytes, without reducing the proportion of terminally-differentiated chondrocytes. Thus, the photodynamic impact inhibits the activity of epiphyseal plates of the mice.

  18. Uplift of Zagros Mountains slows plate convergence

    NASA Astrophysics Data System (ADS)

    Balcerak, Ernie

    2013-05-01

    Research has indicated that mountain ranges can slow down the convergence between two tectonic plates on timescales as short as a few million years, as the growing mountains provide enough tectonic force to impact plate motions. Focusing on the convergence of the Arabian and Eurasian plates at the Zagros mountain range, which runs across Iran and Iraq, Austermann and Iaffaldano reconstructed the relative motion of the plates using published paleomagnetic data covering the past 13 million years, as well as current geodetic measurements. They show that the convergence of the two plates has decreased by about 30% over the past 5 million years. Looking at the geological record to infer past topography and using a computer model of the mantle-lithosphere system, the authors examined whether the recent uplift across the Zagros Mountains could have caused the observed slowdown. They also considered several other geological events that might have influenced the convergence rate, but the authors were able to rule those out as dominant controls. The authors conclude that the uplift across the Zagros Mountains in the past 5 million years did indeed play a key role in slowing down the convergence between the Eurasian and Arabian plates. (Tectonics, doi:10.1002/tect.20027, 2013)

  19. Benchmark for license plate character segmentation

    NASA Astrophysics Data System (ADS)

    Gonçalves, Gabriel Resende; da Silva, Sirlene Pio Gomes; Menotti, David; Shwartz, William Robson

    2016-09-01

    Automatic license plate recognition (ALPR) has been the focus of many researches in the past years. In general, ALPR is divided into the following problems: detection of on-track vehicles, license plate detection, segmentation of license plate characters, and optical character recognition (OCR). Even though commercial solutions are available for controlled acquisition conditions, e.g., the entrance of a parking lot, ALPR is still an open problem when dealing with data acquired from uncontrolled environments, such as roads and highways when relying only on imaging sensors. Due to the multiple orientations and scales of the license plates captured by the camera, a very challenging task of the ALPR is the license plate character segmentation (LPCS) step, because its effectiveness is required to be (near) optimal to achieve a high recognition rate by the OCR. To tackle the LPCS problem, this work proposes a benchmark composed of a dataset designed to focus specifically on the character segmentation step of the ALPR within an evaluation protocol. Furthermore, we propose the Jaccard-centroid coefficient, an evaluation measure more suitable than the Jaccard coefficient regarding the location of the bounding box within the ground-truth annotation. The dataset is composed of 2000 Brazilian license plates consisting of 14000 alphanumeric symbols and their corresponding bounding box annotations. We also present a straightforward approach to perform LPCS efficiently. Finally, we provide an experimental evaluation for the dataset based on five LPCS approaches and demonstrate the importance of character segmentation for achieving an accurate OCR.

  20. Image simulation for automatic license plate recognition

    NASA Astrophysics Data System (ADS)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  1. Corrosion test cell for bipolar plates

    DOEpatents

    Weisbrod, Kirk R.

    2002-01-01

    A corrosion test cell for evaluating corrosion resistance in fuel cell bipolar plates is described. The cell has a transparent or translucent cell body having a pair of identical cell body members that seal against opposite sides of a bipolar plate. The cell includes an anode chamber and an cathode chamber, each on opposite sides of the plate. Each chamber contains a pair of mesh platinum current collectors and a catalyst layer pressed between current collectors and the plate. Each chamber is filled with an electrolyte solution that is replenished with fluid from a much larger electrolyte reservoir. The cell includes gas inlets to each chamber for hydrogen gas and air. As the gases flow into a chamber, they pass along the platinum mesh, through the catalyst layer, and to the bipolar plate. The gas exits the chamber through passageways that provide fluid communication between the anode and cathode chambers and the reservoir, and exits the test cell through an exit port in the reservoir. The flow of gas into the cell produces a constant flow of fresh electrolyte into each chamber. Openings in each cell body is member allow electrodes to enter the cell body and contact the electrolyte in the reservoir therein. During operation, while hydrogen gas is passed into one chamber and air into the other chamber, the cell resistance is measured, which is used to evaluate the corrosion properties of the bipolar plate.

  2. Direct laser engraving of intaglio printing plates

    NASA Astrophysics Data System (ADS)

    Deinhammer, Harald; Loos, Franz; Schwarzbach, Daniel; Fajmann, Peter

    2004-06-01

    Traditionally, Intaglio printing is one of the key security elements for banknotes and security documents, providing high-resolution fine-line elements and the characteristic tactility easily recognized by the public. The conventional process of creating Intaglio printing-plates involves multiple production steps from the hand-engraving of the artist and the computer-aided-design of security elements to the final, print-ready metal plate. We present the results of a feasibility study regarding the direct laser engraving of Intaglio printing-plates. Results of our studies on laser optics and choice of material to achieve optimal line quality are presented. In our studies we have found a novel plate material superior to galvanic nickel regarding plate lengthening and have achieved line widths in the 10μm range. The process found, allows reintroducing true three-dimensional elements with line-depth and -profiling control independent of line-width, while decreasing lead-times in the production of security documents. We give a comparison between direct laser engraving and traditional platemaking, comparing aspects such as resolution, plate performance and production time.

  3. Quantitative assessment of growth plate activity

    SciTech Connect

    Harcke, H.T.; Macy, N.J.; Mandell, G.A.; MacEwen, G.D.

    1984-01-01

    In the immature skeleton the physis or growth plate is the area of bone least able to withstand external forces and is therefore prone to trauma. Such trauma often leads to premature closure of the plate and results in limb shortening and/or angular deformity (varus or valgus). Active localization of bone seeking tracers in the physis makes bone scintigraphy an excellent method for assessing growth plate physiology. To be most effective, however, physeal activity should be quantified so that serial evaluations are accurate and comparable. The authors have developed a quantitative method for assessing physeal activity and have applied it ot the hip and knee. Using computer acquired pinhole images of the abnormal and contralateral normal joints, ten regions of interest are placed at key locations around each joint and comparative ratios are generated to form a growth plate profile. The ratios compare segmental physeal activity to total growth plate activity on both ipsilateral and contralateral sides and to adjacent bone. In 25 patients, ages 2 to 15 years, with angular deformities of the legs secondary to trauma, Blount's disease, and Perthes disease, this technique is able to differentiate abnormal segmental physeal activity. This is important since plate closure does not usually occur uniformly across the physis. The technique may permit the use of scintigraphy in the prediction of early closure through the quantitative analysis of serial studies.

  4. Modeling the hydrodynamics of Phloem sieve plates.

    PubMed

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele; Bohr, Tomas; Knoblauch, Michael; Bruus, Henrik

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  5. Sound absorption by clamped poroelastic plates.

    PubMed

    Aygun, H; Attenborough, K

    2008-09-01

    Measurements and predictions have been made of the absorption coefficient and the surface acoustic impedance of poroelastic plates clamped in a large impedance tube and separated from the rigid termination by an air gap. The measured and predicted absorption coefficient and surface impedance spectra exhibit low frequency peaks. The peak frequencies observed in the absorption coefficient are close to those predicted and measured in the deflection spectra of the clamped poroelastic plates. The influences of the rigidity of the clamping conditions and the width of the air gap have been investigated. Both influences are found to be important. Increasing the rigidity of clamping reduces the low frequency absorption peaks compared with those measured for simply supported plates or plates in an intermediate clamping condition. Results for a closed cell foam plate and for two open cell foam plates made from recycled materials are presented. For identical clamping conditions and width of air gap, the results for the different materials differ as a consequence mainly of their different elasticity, thickness, and cell structure.

  6. Intra Plate Stresses Using Finite Element Modelling

    NASA Astrophysics Data System (ADS)

    Jayalakshmi, S.; Raghukanth, S. T. G.

    2016-10-01

    One of the most challenging problems in the estimation of seismic hazard is the ability to quantify seismic activity. Empirical models based on the available earthquake catalogue are often used to obtain activity of source regions. The major limitation with this approach is the lack of sufficient data near a specified source. The non-availability of data poses difficulties in obtaining distribution of earthquakes with large return periods. Such events recur over geological time scales during which tectonic processes, including mantle convection, formation of faults and new plate boundaries, are likely to take place. The availability of geometries of plate boundaries, plate driving forces, lithospheric stress field and GPS measurements has provided numerous insights on the mechanics of tectonic plates. In this article, a 2D finite element model of Indo-Australian plate is developed with the focus of representing seismic activity in India. The effect of large scale geological features including sedimentary basins, fold belts and cratons on the stress field in India is explored in this study. In order to address long term behaviour, the orientation of stress field and tectonic faults of the present Indo- Australian plate are compared with a reconstructed stress field from the early Miocene (20 Ma).

  7. Abrupt plate accelerations shape rifted continental margins.

    PubMed

    Brune, Sascha; Williams, Simon E; Butterworth, Nathaniel P; Müller, R Dietmar

    2016-08-11

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth's major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength--velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time.

  8. Wavelength calibration of objective prism plates by transformation from direct plates

    NASA Astrophysics Data System (ADS)

    Tucholke, Hans-Joachim

    The zero points for galaxy redshift measurements from objective prison plates are obtained through the transformation of object positions from the corresponding direct plates. About 1000 G-stars per plate are employed. The transformation characteristics for three adjacent fields near the South Galactic Pole are presented. The mean residuals are about 5 microns, corresponding to a redshift error of about 700 km/s at z = 0.

  9. Current plate velocities relative to the hotspots incorporating the NUVEL-1 global plate motion model

    SciTech Connect

    Gripp, A.E.; Gordon, R.G. )

    1990-07-01

    NUVEL-1 is a new global model of current relative plate velocities which differ significantly from those of prior models. Here the authors incorporate NUVEL-1 into HS2-NUVEL1, a new global model of plate velocities relative to the hotspots. HS2-NUVEL1 was determined from the hotspot data and errors used by Minster and Jordan (1978) to determine AM1-2, which is their model of plate velocities relative to the hotspots. AM1-2 is consistent with Minster and Jordan's relative plate velocity model RM2. Here the authors compare HS2-NUVEL1 with AM1-2 and examine how their differences relate to differences between NUVEL-1 and RM2. HS2-NUVEL1 plate velocities relative to the hotspots are mainly similar to those of AM1-2. Minor differences between the two models include the following: (1) in HS2-NUVEL1 the speed of the partly continental, apparently non-subducting Indian plate is greater than that of the purely oceanic, subducting Nazca plate; (2) in places the direction of motion of the African, Antarctic, Arabian, Australian, Caribbean, Cocos, Eurasian, North American, and South American plates differs between models by more than 10{degree}; (3) in places the speed of the Australian, Caribbean, Cocos, Indian, and Nazca plates differs between models by more than 8 mm/yr. Although 27 of the 30 RM2 Euler vectors differ with 95% confidence from those of NUVEL-1, only the AM1-2 Arabia-hotspot and India-hotspot Euler vectors differ with 95% confidence from those of HS2-NUVEL1. Thus, substituting NUVEL-1 for RM2 in the inversion for plate velocities relative to the hotspots changes few Euler vectors significantly, presumably because the uncertainty in the velocity of a plate relative to the hotspots is much greater than the uncertainty in its velocity relative to other plates.

  10. Finite Element Analysis of Elasto-plastic Plate Bending Problems using Transition Rectangular Plate Elements

    NASA Astrophysics Data System (ADS)

    Kanber, Bahattin; Bozkurt, O. Yavuz

    2006-08-01

    In this work, the finite element analysis of the elasto-plastic plate bending problems is carried out using transition rectangular plate elements. The shape functions of the transition plate elements are derived based on a practical rule. The transition plate elements are all quadrilateral and can be used to obtain efficient finite element models using minimum number of elements. The mesh convergence rates of the models including the transition elements are compared with the regular element models. To verify the developed elements, simple tests are demonstrated and various elasto-plastic problems are solved. Their results are compared with ANSYS results.

  11. Assumed strain distributions for a finite strip plate bending element using Mindlin-Reissner plate theory

    NASA Technical Reports Server (NTRS)

    Chulya, Abhisak; Mullen, Robert L.

    1989-01-01

    A linear finite strip plate element based on Mindlin-Reissner plate theory is developed. The analysis is suitable for both thin and thick plates. In the formulation, new transverse shear strains are introduced and assumed constant in each two-node linear strip. The element stiffness matrix is explicitly formulated for efficient computation and computer implementation. Numerical results showing the efficiency and predictive capability of the element for the analysis of plates are presented for different support and loading conditions and a wide range of thicknesses. No sign of shear locking is observed with the newly developed element.

  12. Disseminated thrombosis-induced growth plate necrosis in rat: a unique model for growth plate arrest.

    PubMed

    Nyska, Meir; Shabat, Shay; Long, Philip H; Howard, Charles; Ezov, Nathan; Levin-Harrus, Tal; Mittelman, Moshe; Redlich, Meir; Yedgar, Saul; Nyska, Abraham

    2005-01-01

    Exposure of rats to 2-butoxyethanol (BE) produces early hemolytic anemia and disseminated thrombosis. This leads to infarctions in multiple organs, including bones and cartilage. BE, administered for different durations of exposure in two separate experiments, produced metaphyseal vascular thrombosis, growth plate infarction, and partial or complete physeal growth arrest. This reproducible model may serve as a useful tool in the study of some conditions that manifest growth plate damage. The suitability of this model for investigating the pathogenesis of growth plate necrosis and as a model for potential therapy for various human growth plate disorders are discussed.

  13. Creation of the Cocos and Nazca plates by fission of the Farallon plate

    NASA Astrophysics Data System (ADS)

    Lonsdale, Peter

    2005-08-01

    Throughout the Early Tertiary the area of the Farallon oceanic plate was episodically diminished by detachment of large and small northern regions, which became independently moving plates and microplates. The nature and history of Farallon plate fragmentation has been inferred mainly from structural patterns on the western, Pacific-plate flank of the East Pacific Rise, because the fragmented eastern flank has been subducted. The final episode of plate fragmentation occurred at the beginning of the Miocene, when the Cocos plate was split off, leaving the much reduced Farallon plate to be renamed the Nazca plate, and initiating Cocos-Nazca spreading. Some Oligocene Farallon plate with rifted margins that are a direct record of this plate-splitting event has survived in the eastern tropical Pacific, most extensively off northern Peru and Ecuador. Small remnants of the conjugate northern rifted margin are exposed off Costa Rica, and perhaps south of Panama. Marine geophysical profiles (bathymetric, magnetic and seismic reflection) and multibeam sonar swaths across these rifted oceanic margins, combined with surveys of 30-20 Ma crust on the western rise-flank, indicate that (i) Localized lithospheric rupture to create a new plate boundary was preceded by plate stretching and fracturing in a belt several hundred km wide. Fissural volcanism along some of these fractures built volcanic ridges (e.g., Alvarado and Sarmiento Ridges) that are 1-2 km high and parallel to "absolute" Farallon plate motion; they closely resemble fissural ridges described from the young western flank of the present Pacific-Nazca rise. (ii) For 1-2 m.y. prior to final rupture of the Farallon plate, perhaps coinciding with the period of lithospheric stretching, the entire plate changed direction to a more easterly ("Nazca-like") course; after the split the northern (Cocos) part reverted to a northeasterly absolute motion. (iii) The plate-splitting fracture that became the site of initial Cocos

  14. Large Deflections of Elastic Rectangular Plates

    NASA Astrophysics Data System (ADS)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  15. Unsteady aerodynamics of fluttering and tumbling plates

    NASA Astrophysics Data System (ADS)

    Andersen, A.; Pesavento, U.; Wang, Z. Jane

    2005-10-01

    We investigate the aerodynamics of freely falling plates in a quasi-two-dimensional flow at Reynolds number of 10(3) , which is typical for a leaf or business card falling in air. We quantify the trajectories experimentally using high-speed digital video at sufficient resolution to determine the instantaneous plate accelerations and thus to deduce the instantaneous fluid forces. We compare the measurements with direct numerical solutions of the two-dimensional Navier Stokes equation. Using inviscid theory as a guide, we decompose the fluid forces into contributions due to acceleration, translation, and rotation of the plate. For both fluttering and tumbling we find that the fluid circulation is dominated by a rotational term proportional to the angular velocity of the plate, as opposed to the translational velocity for a glider with fixed angle of attack. We find that the torque on a freely falling plate is small, i.e. the torque is one to two orders of magnitude smaller than the torque on a glider with fixed angle of attack. Based on these results we revise the existing ODE models of freely falling plates. We get access to different kinds of dynamics by exploring the phase diagram spanned by the Reynolds number, the dimensionless moment of inertia, and the thickness-to-width ratio. In agreement with previous experiments, we find fluttering, tumbling, and apparently chaotic motion. We further investigate the dependence on initial conditions and find brief transients followed by periodic fluttering described by simple harmonics and tumbling with a pronounced period-two structure. Near the cusp-like turning points, the plates elevate, a feature which would be absent if the lift depended on the translational velocity alone.

  16. Electroless Nickel Phosphorus Plating on AZ31

    NASA Astrophysics Data System (ADS)

    Shartal, Kh. M.; Kipouros, G. J.

    2009-04-01

    One of the major drawbacks to using magnesium parts in automotive applications is poor corrosion resistance, which can be improved with a nickel-boron coating placed on a nickel-phosphorus coating, which, in turn, is placed on a phosphate-permanganate conversion-coating layer produced on the magnesium alloy AZ31. This work reports on the determination of the optimum kinetic parameters for producing a coherent nickel-phosphorus coating using an electroless-procedure phosphate-permanganate conversion-coating layer and for studying the effects of the experimental variables of the electroless plating process on the phosphorus content, surface morphology, and structure of the electroless nickel-phosphorus (EN-P) coatings produced. Measurements of the plating rate as a function of experimental variables such as the compositions of the plating bath constituents, temperature, and pH were implemented using the weight-gain method; the phosphorus content of the EN-P coatings was measured using energy-dispersive spectroscopy (EDS) analysis. The surface morphology of the coating was examined using a scanning electron microscope (SEM); X-ray diffraction (XRD) was used to characterize the structure of each coating. An empirical rate law was determined for EN-P plating on a phosphate-permanganate conversion coating. It is found that the deposition rate of the EN-P coating increases by increasing the deposition temperature, the concentration of free nickel ions, and the concentration of hypophosphite ions in the plating bath. In addition, the deposition rate decreases by increasing both the plating bath pH and the concentration of citric acid in the plating bath.

  17. Motion of the Scotia sea plates

    USGS Publications Warehouse

    Thomas, C.; Livermore, R.; Pollitz, F.

    2003-01-01

    Earthquake data from the Scotia Arc to early 2002 are reviewed in the light of satellite gravity and other data in order to derive a model for the motion of plates in the Scotia Sea region. Events with magnitude ???5, which occurred on or near the boundaries of the Scotia and Sandwich plates, and for which Centroid Moment Tensor (CMT) solutions are available, are examined. The newer data fill some of the previous sampling gaps along the boundaries of the Scotia and Sandwich plates, and provide tighter constraints on relative motions. Variations in the width of the Brunhes anomaly on evenly spaced marine magnetic profiles over the East Scotia Ridge provide new estimates of Scotia-Sandwich plate spreading rates. Since there are no stable fracture zones in the east Scotia Sea, the mean azimuth of sea floor fabric mapped by sidescan is used to constrain the direction of spreading. 18 new rate estimates and four azimuths from the East Scotia Ridge are combined with 68 selected earthquake slip vectors from the boundaries of the Scotia Sea in a least-squares inversion for the best-fitting set of Euler poles and angular rotation rates describing the 'present-day' motions of the Scotia and Sandwich plates relative to South America and Antarctica. Our preferred model (TLP2003) gives poles that are similar to previous estimates, except for Scotia Plate motion with respect to South America, which is significantly different from earlier estimates; predicted rates of motion also differ slightly. Our results are much more robust than earlier work. We examine the implications of the model for motion and deformation along the various plate boundaries, with particular reference to the North and South Scotia Ridges, where rates are obtained by closure.

  18. Towards modelling the evolution of intra plate stress: the Eurasian plate 20 Ma.

    NASA Astrophysics Data System (ADS)

    Quéré, Sandrine; Ruckstuhl, Karin; Wortel, Rinus; Govers, Rob; Hochard, Cyril; Stampfli, Gérard

    2010-05-01

    In this study, we investige the evolution of the intra plate stress field. We use the classical characterisation of forces acting regionally on a plate such as 'slab pull/suction', 'ridge push' and 'mantle drag' as used by Forsyth & Uyeda (1975), Chapple & Tullis (1977) and later by Wortel et al. (1991) and Govers & Meijer (2001). So far, the interaction between the lithosphere and the underlying mantle flow was oversimplified and implemented via a coupling cœfficient in the direction of the plate motion and we propose improving this specific interaction. As the shear stress field at the base of the plates is unknown in the past, we propose using a mantle flow simulation induced by the imposition of past plate motions on top of a 3D spherical mantle convective code. To that purpose, we employ the new plate motion reconstruction developed by Stampfli et al. (2008) and a 3D convective code where plates are dynamically coupled to the mantle (Quéré & Forte, 2006). The first plate on which we apply this method is the Eurasian plate as Eurasia is a large plate with a small velocity (not attached to its own subduction zone) and the debate on the main driving forces acting on Eurasia is still going on. The stress field 20 Ma resulting from all plate tectonic forces is calculated by assuming mechanical equilibrium in an homogeneous elastic shell using the plane stress approximation. As direct stress indicators for the past are rare, the predicted paleo-stress field is compared to pertinent data from orogens and extensional basins which will provide new clues to oil exploration teams.

  19. 49 CFR 451.21 - Safety approval plate required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Safety approval plate required. 451.21 Section 451... HOMELAND SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.21 Safety approval plate required. (a) The safety approval plate must be supplied by...

  20. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  1. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  2. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  3. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  4. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  5. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  6. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  7. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  8. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  9. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  10. 49 CFR 179.300-6 - Thickness of plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... psig; S = minimum tensile strength of plate material in p.s.i. as prescribed in § 179.300-7; t... stress in psig (c) If plates are clad with material having tensile strength at least equal to the base... cladding material does not have tensile strength at least equal to the base plate, the base plate...

  11. Making More Efficient Use Of Battery-Plate Mass

    NASA Technical Reports Server (NTRS)

    Rowlette, John J.

    1990-01-01

    Improved active material for positive plate of lead/acid electric storage battery made with additional porosity to give electrolyte access to larger plate-surface area. 65 to 68 percent of active mass of plate used to generate electric current. Batteries with new plate material offer extremely long cycle life.

  12. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor.

    PubMed

    Chen, Pin-Chuan; Park, Daniel S; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A; Nikitopoulos, Dimitris E; Murphy, Michael C

    2010-08-06

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date.

  13. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor

    PubMed Central

    Chen, Pin-Chuan; Park, Daniel S.; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A.; Nikitopoulos, Dimitris E.; Murphy, Michael C.

    2010-01-01

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date. PMID:20871807

  14. LOWLID FORMATION AND PLATE TECTONICS ON EXOPLANETS

    NASA Astrophysics Data System (ADS)

    Stamenkovic, V.; Noack, L.; Breuer, D.

    2009-12-01

    The last years of astronomical observation have opened the doors to a universe filled with extrasolar planets. Detection techniques still only offer the possibility to detect mainly Super-Earths above five Earth masses. But detection techniques do steadily improve and are offering the possibility to detect even smaller planets. The observations show that planets seem to exist in many possible sizes just as the planets and moons of our own solar system do. It is only a natural question to ask if planetary mass has an influence on some key habitability factors such as on plate tectonics, allowing us to test which exoplanets might be more likely habitable than others, and allowing us to understand if plate tectonics on Earth is a stable or a critical, instable process that could easily be perturbed. Here we present results derived from 1D parameterized thermal evolution and 2D/3D computer models, showing how planetary mass influences the propensity of plate tectonics for planets with masses ranging from 0.1 to 10 Earth masses. Lately [2, 3] studied the effect of planetary mass on the ability to break plates and hence initiate plate tectonics - but both derived results contradictory to the other. We think that one of the reasons why both studies [2, 3] are not acceptable in their current form is partly due to an oversimplification. Both treated viscosity only temperature-dependent but neglected the effect pressure has on enlarging the viscosity in the deep mantle. More massive planets have therefore a stronger pressure-viscosity-coupling making convection at high pressures sluggish or even impossible. For planets larger than two Earth masses we observe that a conductive lid (termed low-lid) forms above the core-mantle boundary and thus reduces the effective convective part of the mantle when including a pressure-dependent term into the viscosity laws as shown in [1]. Moreover [2, 3] use time independent steady state models neglecting the fact that plate tectonics is a

  15. Current plate motions. [continental groupings and global modelling

    NASA Technical Reports Server (NTRS)

    Demets, C.; Gordon, R. G.; Argus, D. F.; Stein, S.

    1990-01-01

    A global plate motion model, named NUVEL-1, which describes current plate motions between 12 rigid plates is described, with special attention given to the method, data, and assumptions used. Tectonic implications of the patterns that emerged from the results are discussed. It is shown that wide plate boundary zones can form not only within the continental lithosphere but also within the oceanic lithosphere; e.g., between the Indian and Australian plates and between the North American and South American plates. Results of the model also suggest small but significant diffuse deformation of the oceanic lithosphere, which may be confined to small awkwardly shaped salients of major plates.

  16. Finite element modeling of stress in the Nazca plate - Driving forces and plate boundary earthquakes

    NASA Technical Reports Server (NTRS)

    Richardson, R. M.

    1978-01-01

    The state of stress within the Nazca plate due to plate driving forces and large plate boundary earthquakes has been analyzed by applying a finite element method using the wave front solution technique to models of the intraplate stress field in a single plate using a refined grid. Although only static elastic models have been explicitly calculated, certain limiting cases of an elastic plate over a viscous asthenosphere were also treated. A state of nearly east-west compression inferred from the source mechanism of thrust earthquakes in the interior of the plate requires ridge pushing forces. The net pulling force on the oceanic plate by the subducted slab has a maximum value comparable to pushing forces. The estimated horizontal deviatoric stress in intraplate regions, based on potential forces associated with the ridge, is on the order of a few hundred bars. The intraplate stress field in the region of the 1960 earthquake may change by a few tens of bars at most once the asthenosphere has relaxed, with changes on the order of one bar occurring at greater distances into the plate. The changes in the intraplate stress field are probably not noticeable unless the lithosphere is near failure.

  17. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  18. Guided waves in a jointed composite plate

    SciTech Connect

    Karunasena, W.; Shah, A.H. ); Datta, S.K. )

    1994-03-01

    Reflection of guided waves by a thin region of bonding material at the interface between two composite plates has been investigated in this paper. The study is motivated by the need to develop a quantitative ultrasonic technique to characterize properties of joints between two plates, which may be laminated and anisotropic. Although there have been some recent studies that have examined the reflection and transmission of surface waves at the interface between two plates, they consider the two plates to be semi-infinite in thickness. Thus the mode conversion of waves into higher guided modes of the plates are not taken into account. In this paper, a model study of the interaction of the [ital A][sub 0] and [ital S][sub 0] guided wave modes with the joint material is presented. It is shown that as the frequency increases the coefficient of reflection shows resonant peaks at the cutoff frequencies of higher guided modes. These peaks become increasingly pronounced as the thickness of the joint increases. Another interesting feature is that the reflection coefficients have minima at a frequency that depends on the thickness and the properties of the joint material. These features can be used to determine the relevant properties of the joint.

  19. Geometrically nonlinear behavior of piezoelectric laminated plates

    NASA Astrophysics Data System (ADS)

    Rabinovitch, Oded

    2005-08-01

    The geometrically nonlinear behavior of piezo-laminated plates actuated with isotropic or anisotropic piezoelectric layers is analytically investigated. The analytical model is derived using the variational principle of virtual work along with the lamination and plate theories, the von Karman large displacement and moderate rotation kinematic relations, and the anisotropic piezoelectric constitutive laws. A solution strategy that combines the approach of the method of lines, the advantages of the finite element concept, and the variational formulation is developed. This approach yields a set of nonlinear ordinary differential equations with nonlinear boundary conditions, which are solved using the multiple-shooting method. Convergence and verification of the model are examined through comparison with linear and nonlinear results of other approximation methods. The nonlinear response of two active plate structures is investigated numerically. The first plate is actuated in bending using monolithic piezoceramic layers and the second one is actuated in twist using macro-fiber composites. The results quantitatively reveal the complicated in-plane stress state associated with the piezoelectric actuation and the geometrically nonlinear coupling of the in-plane and out-of-plane responses of the plate. The influence of the nonlinear effects ranges from significant stiffening in certain combinations of electrical loads and boundary conditions to amplifications of the induced deflections in others. The paper closes with a summary and conclusions.

  20. Ridge push engine of plate tectonics

    NASA Astrophysics Data System (ADS)

    Swedan, N. H.

    2015-07-01

    Convection of the upper mantle drives the tectonic plates. This convection is a thermodynamic cycle that exchanges heat and mechanical work between mantle and tectonic plates. Thermodynamics and observations indicate that the energy of the geological activities resulting from plate tectonics is equal to the latent heat of melting, calculated at mantle's pressure, of the new ocean crust regenerated at midocean ridges. This energy varies with the temperature of ocean floor, which is correlated with surface temperature. The main objective of this manuscript is to demonstrate that plate tectonics is a thermodynamic engine and can be calculated as such. Unlike existing tectonic models, the thermodynamic model is very sensitive to variations of the temperature of ocean floor, which is correlated with surface temperature. Therefore, the observed increase of geological activities can be projected with surface temperature rise. Other objectives of the manuscript are to calculate the force that drives the tectonic plates, estimate the energy released, and validate the calculations based on experiments and observations. In addition to the scientific merit of projecting the geological activities, a good projection can have a broader impact at the societal and economical levels. Investment and insurance related decisions are affected by climate change, and our ability to project the geological activities is of paramount importance for the economy and public safety. This work can thus provide tools to assess the risks and hazards associated with the trend of geological activities with surface temperature rise.

  1. Tectonic development of the Maya plate

    SciTech Connect

    Charleston, S.; Concit, S.C.; Sanchez, R.

    1985-01-01

    The Maya Plate is located at the southern margin of the North American Plate, it comprises from north to south, the following tectonic provinces: The Yucatan Platform, (including the lowlands of Peten and the oil-rich offshore platform of the Campeche Bank), the Macuspana basin, the Salt Basin, the NW-SE trending Sierra de Chiapas Folded Belt, the Chiapas depression and the Ciapas Massif. During the past, the deformation of the Maya Plate, have been attributed to the Laramide Orogeny. The present study develops a model based on the interaction between the Maya, Caribbean and the oceanic Cocos-plates, assuming that during the Middle Miocene, the development of the left-lateral Motagua Fault between the Maya and Caribbean plates, displaced the Yucatan Platform in a southwestward direction. It is consider that the combine action of two opposite forces, was responsible for the development of most of the Sierra de Chiapas major anticlines and synclines. Finally the model suggests that these structures, were later affected by trans-compressive forces, originated as a secondary response, due to the development of several left-lateral transcurrent faults, associated with the Polochic Fault System.

  2. Computer animation of Phanerozoic plate motions

    SciTech Connect

    Scotese, C.R. . Dept. of Geology)

    1992-01-01

    Since 1985, the PALEOMAP Project, in collaboration with research groups both in the US and abroad, has assembled a digital model that describes global plate motions during the last 600 million years. In this paper the authors present a series of computer animations that dynamically illustrates the movement of continents and terranes, and the evolution of the ocean basins since the breakup of the late Precambrian supercontinent. These animations depict the motion of the plates from both equatorial and polar perspectives. Mesozoic and Cenozoic plate tectonic reconstructions are based on a synthesis of linear magnetic anomalies, fracture zone locations, intracontinental rifts, collision and thrust belts, and zones of strike-slip. Paleozoic plate reconstructions, though more speculative, are based on evidence of past subduction, continental collision, and inferred sea floor spreading. The relative longitudinal positions of the continents during the Paleozoic and the width of intervening oceans have been adjusted to best explain changing biogeographic and paleoclimatic patterns. A new paleomagnetic/hot spot reference frame has been constructed that combines paleomagnetic data compiled by Rob Van der Voo (1992) with inferred motion relative to a fixed frame of hot spots. Using probable Early Mesozoic and Paleozoic hot spot tracks on the major continents, the authors have extended plate motions relative to the hot spot reference frame back to 400 million years.

  3. Variable Phase for Fresnel Zone Plates

    NASA Astrophysics Data System (ADS)

    Webb, George W.

    2004-03-01

    It is not widely known that there is a free parameter in the usual design of zone plates. An earlier work treated the radius of the central Fresnel zone as the free parameter and investigated the effects of its variation numerically [1]. It is possible instead to treat the choice of reference phase in the design of a zone plate as the free parameter [2]. The standard zone plate construction assumes a specific choice for this phase which, however, can be chosen to have any value between 0^o and 360^o. Here we present analysis and measurements on zone plates for 39 GHz radiation with reference phase varied from 0^o to 360^o. When the reference phase is varied, measurements show that the phase of the focused beam is varied in a nearly linear fashion through 360^o with only small changes in beam amplitude. It is concluded that reference phase is an inherent and useful property of zone plates. 1) I.V. Minin and O.V. Minin, Sov. J. Quantum Electron. derline 20, 198 (1990). I thank I.V. Minin for calling this work to my attention. 2) G.W. Webb, Proc. 2003 Antenna Applications Symposium, Allerton Park, Monticello, IL, September 15-17, 2003 and arXiv:physics/0303002 28 Feb 2003.

  4. The role of viscoelasticity in subducting plates

    NASA Astrophysics Data System (ADS)

    Farrington, R. J.; Moresi, L.-N.; Capitanio, F. A.

    2014-11-01

    of tectonic plates into Earth's mantle occurs when one plate bends beneath another at convergent plate boundaries. The characteristic time of deformation at these convergent boundaries approximates the Maxwell relaxation time for olivine at lithospheric temperatures and pressures, it is therefore by definition a viscoelastic process. While this is widely acknowledged, the large-scale features of subduction can, and have been, successfully reproduced assuming the plate deforms by a viscous mechanism alone. However, the energy rates and stress profile within convergent margins are influenced by viscoelastic deformation. In this study, viscoelastic stresses have been systematically introduced into numerical models of free subduction, using both the viscosity and shear modulus to control the Maxwell relaxation time. The introduction of an elastic deformation mechanism into subduction models produces deviations in both the stress profile and energy rates within the subduction hinge when compared to viscous only models. These variations result in an apparent viscosity that is variable throughout the length of the plate, decreasing upon approach and increasing upon leaving the hinge. At realistic Earth parameters, we show that viscoelastic stresses have a minor effect on morphology yet are less dissipative at depth and result in an energy transfer between the energy stored during bending and the energy released during unbending. We conclude that elasticity is important during both bending and unbending within the slab hinge with the resulting stress loading and energy profile indicating that slabs maintain larger deformation rates at smaller stresses during bending and retain their strength during unbending at depth.

  5. Recovery process for electroless plating baths

    DOEpatents

    Anderson, R.W.; Neff, W.A.

    1992-05-12

    A process is described for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO[sub 3]. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths. 18 figs.

  6. Recovery process for electroless plating baths

    DOEpatents

    Anderson, Roger W.; Neff, Wayne A.

    1992-01-01

    A process for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO.sub.3. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths.

  7. Spirit Begins Drive Around Home Plate

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The hazard avoidance camera on the front of NASA's Mars Exploration Rover Spirit took this image after a drive by Spirit on the 1,829th Martian day, or sol, of Spirit's mission on the surface of Mars (Feb. 24, 2009).

    On Sol 1829, Spirit drove 6.29 meters (21 feet) northwestward, away from the northern edge of the low plateau called 'Home Plate.' The track dug by the dragged right-front wheel as the rover drove backward is visible in this image, receding toward the southeast. Rock layers of the northern slope of Home Plate are visible in the upper right portion of the image.

    In sols prior to 1829, the rover team had been trying to maneuver Spirit to climb onto the northern edge of Home Plate, ready to drive southward across the top of the plateau toward science destinations south of Home Plate. The Sol 1829 drive was the first move of a revised strategy to circle at least partway around Home Plate on the trek toward the sites south of the plateau.

  8. Lasting mantle scars lead to perennial plate tectonics

    PubMed Central

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a ‘perennial' phenomenon. PMID:27282541

  9. Lasting mantle scars lead to perennial plate tectonics.

    PubMed

    Heron, Philip J; Pysklywec, Russell N; Stephenson, Randell

    2016-06-10

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a 'perennial' phenomenon.

  10. Lasting mantle scars lead to perennial plate tectonics

    NASA Astrophysics Data System (ADS)

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-06-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a `perennial' phenomenon.

  11. Recent research on the growth plate: Recent insights into the regulation of the growth plate.

    PubMed

    Lui, Julian C; Nilsson, Ola; Baron, Jeffrey

    2014-08-01

    For most bones, elongation is driven primarily by chondrogenesis at the growth plates. This process results from chondrocyte proliferation, hypertrophy, and extracellular matrix secretion, and it is carefully orchestrated by complex networks of local paracrine factors and modulated by endocrine factors. We review here recent advances in the understanding of growth plate physiology. These advances include new approaches to study expression patterns of large numbers of genes in the growth plate, using microdissection followed by microarray. This approach has been combined with genome-wide association studies to provide insights into the regulation of the human growth plate. We also review recent studies elucidating the roles of bone morphogenetic proteins, fibroblast growth factors, C-type natriuretic peptide, and suppressor of cytokine signaling in the local regulation of growth plate chondrogenesis and longitudinal bone growth.

  12. Performance evaluation of the R6R018 fuel plate using PLATE code

    SciTech Connect

    Pavel G. Medvedev; Hakan Ozaltun

    2010-03-01

    The paper presents results of performance evaluation of the R6R018 fuel plate using PLATE code. R6R018 is a U-7Mo dispersion type mini-plate with Al-3.5Si matrix irradiated in the RERTR-9B experiment. The design of this plate is prototypical of the planned LEONIDAS irradiation test. Therefore, a detailed performance analysis of this plate is important to confirm acceptable behavior in pile, and to provide baseline and justification for further analysis and testing. Specific results presented in the paper include fuel temperature history, growth of the interaction layer between the U-Mo and the matrix, swelling, growth of the corrosion layer, and degradation of thermal conductivity. The methodology of the analysis will be discussed including the newly developed capability to account for the formation of the interaction layer during fuel fabrication.

  13. Plate on plate osteosynthesis for the treatment of nonhealed periplate fractures.

    PubMed

    Arealis, Georgios; Nikolaou, Vassilios S; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation.

  14. Highly conductive composites for fuel cell flow field plates and bipolar plates

    DOEpatents

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  15. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  16. Microporous microchannel plates and method of manufacturing same

    DOEpatents

    Beetz, Jr., Charles P.; Boerstler, Robert W.; Steinbeck, John; Winn, David R.

    2000-01-01

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  17. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in...

  18. The Okhotsk Plate and the Eurasia-North America plate boundary zone.

    NASA Astrophysics Data System (ADS)

    Hindle, David; Mackey, Kevin

    2014-05-01

    The Eurasia-North America plate boundary zone transitions from spreading at rates of ~ 25mm/yr in the North Atlantic, to compression at rates of ~ 5mm/yr in the region of the Okhotsk plate. Because the pole of rotation between Eurasia and North America lies more or less on their mutual boundary, there is a linear change in rate along the boundary, and regions near the euler pole are subject to extremely low deformation rates. The Okhotsk - Eurasia - North America triple junction lies slightly south of the rotation pole, placing the Okhotsk plate entirely in a weakly contractional setting. Regions near the triple junction absorb 1mm/yr contraction. Further south, towards the shoreline of the Okhotsk sea, up to 5 mm/yr contraction may be absorbed within the plate. How shortening is accommodated across the boundary remains an open question. One possibility is wholesale extrusion of the entire Okhotsk plate (or possibly its northwestern corner) along two plate boundary strike slip faults (Eurasia-Okhostk and North America Okhotsk). The problem with this model is that the seismic record does not presently clearly support it, with the largest events distributed both within the plate interior and on its boundaries. This may suggest that instead, the Okhotsk plate, and particularly its north-western end, consists of a series of smaller blocks which shuffle against each other, partially accommodating extrusion, but also permitting some internal deformation and change of shape of the Okhotsk plate itself. We present analyses of the very sparse seismic record from the region, as well as geometric-kinematic, tectonic models of the possible deformation of northwest Okhotsk to try to better understand the different probabilities of how this slowly deforming plate boundary zone is behaving.

  19. Dynamic response of visco-elastic plates

    NASA Astrophysics Data System (ADS)

    Kadıoǧlu, Fethi; Tekin, Gülçin

    2016-12-01

    In this study, a comprehensive analysis about the dynamic response characteristics of visco-elastic plates is given. To construct the functional in the Laplace-Carson domain for the analysis of visco-elastic plates based on the Kirchhoff hypothesis, functional analysis method is employed. By using this new energy functional in the Laplace-Carson domain, moment values that are important for engineers can be obtained directly with excellent accuracy and element equations can be written explicitly. Three-element model is considered for modelling the visco-elastic material behavior. The solutions obtained in the Laplace-Carson domain by utilizing mixed finite element formulation are transformed to the time domain using the Durbin's inverse Laplace transform technique. The proposed mixed finite element formulation is shown to be simple to implement and gives satisfactory results for dynamic response of visco-elastic plates.

  20. Retardation Measurements of Infrared PVA Wave plate

    NASA Astrophysics Data System (ADS)

    Sun, Y.; Z, H.; W, D.; D, Y.; Z, Z.; S, J.

    The wave plate made of Polyvinyl Alcohol PVA plastic film has several advantages such as its lower cost and insensitivity to temperature and incidence angle so it has been used in the Solar Multi-Channel Telescope SMCT in China But the important parameter retardations of PVA wave plates in the near infrared wavelength have never been provided In this paper a convenient and high precise instrument to get the retardations of discrete wavelengths or a continuous function of wavelength in near infrared is developed In this method the retardations of wave plates have been determined through calculating the maximum and minimum of light intensity The instrument error has been shown Additionally we can get the continuous direction of wavelength retardations in the ultraviolet visible or infrared spectral in another way

  1. Flow of nanofluid past a Riga plate

    NASA Astrophysics Data System (ADS)

    Ahmad, Adeel; Asghar, Saleem; Afzal, Sumaira

    2016-03-01

    This paper studies the mixed convection boundary layer flow of a nanofluid past a vertical Riga plate in the presence of strong suction. The mathematical model incorporates the Brownian motion and thermophoresis effects due to nanofluid and the Grinberg-term for the wall parallel Lorentz force due to Riga plate. The analytical solution of the problem is presented using the perturbation method for small Brownian and thermophoresis diffusion parameters. The numerical solution is also presented to ensure the reliability of the asymptotic method. The comparison of the two solutions shows an excellent agreement. The correlation expressions for skin friction, Nusselt number and Sherwood number are developed by performing linear regression on the obtained numerical data. The effects of nanofluid and the Lorentz force due to Riga plate, on the skin friction are discussed.

  2. Plate tectonics drive tropical reef biodiversity dynamics

    NASA Astrophysics Data System (ADS)

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-05-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  3. Drag Measurements of Porous Plate Acoustic Liners

    NASA Technical Reports Server (NTRS)

    Wolter, John D.

    2005-01-01

    This paper presents the results of direct drag measurements on a variety of porous plate acoustic liners. The existing literature describes numerous studies of drag on porous walls with injection or suction, but relatively few of drag on porous plates with neither injection nor suction. Furthermore, the porosity of the porous plate in existing studies is much lower than typically used in acoustic liners. In the present work, the acoustic liners consisted of a perforated face sheet covering a bulk acoustic absorber material. Factors that were varied in the experiment were hole diameter, hole pattern, face sheet thickness, bulk material type, and size of the gap (if any) between the face sheet and the absorber material.

  4. Second-generation zone plate antenna design

    NASA Astrophysics Data System (ADS)

    Wiltse, James C.

    1999-11-01

    A well-designed phase correcting Fresnel zone plate antenna can provide performance superior to a lens or, in some cases, a paraboloid antenna, particularly at millimeter wavelengths. This paper discusses design considerations and includes approaches to give improved characteristics, such as greater efficiency or higher gain. The approaches include the use of quarter-wave or better correction, thickness designs that permit the central zone and other zones to be air dielectric (for lower losses), and the use of low dielectric constant materials to reduce surface reflections and multiple reflections. At higher millimeter-wave or sub- millimeter wavelengths low loss materials are important. More sophisticated zoning is described, as well as the use of a compromise thickness to compensate for the fact that refraction of waves at the surfaces causes the path lengths through the zone plate to be different at different angles of incidence. Multiple-band zone plates are discussed.

  5. Composite plates impact damage - An atlas

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1991-01-01

    The present volume on impact damage in composite plates presents an extensive compendium of visual and graphic data regarding a variety of material and impactor parameters. The photographs are taken with X-ray and C-scan imaging in conjunction with a dye penetrant to show matrix cracks and delaminations. Impact and static-loading tests are performed on plates of graphite-epoxy, graphite-toughened epoxy, and graphite-PEEK materials. The images are presented to yield specific visual data regarding such parameters as impactor velocity, thickness of the back ply group, impactor nose radius, and the effects of multiple delaminations. The images are grouped in eight subsets that correspond to parameters including plate length, material, and the difference in fiber orientation between adjacent ply groups. This substantial volume represents a systematic effort to study the effects of several material parameters on impact damage.

  6. Caribbean tectonics and relative plate motions

    NASA Technical Reports Server (NTRS)

    Burke, K.; Dewey, J. F.; Cooper, C.; Mann, P.; Pindell, J. L.

    1984-01-01

    During the last century, three different ways of interpreting the tectonic evolution of the Gulf of Mexico and the Caribbean have been proposed, taking into account the Bailey Willis School of a permanent pre-Jurassic deep sea basin, the Edward Suess School of a subsided continental terrain, and the Alfred Wegener School of continental separation. The present investigation is concerned with an outline of an interpretation which follows that of Pindell and Dewey (1982). An attempt is made to point out ways in which the advanced hypotheses can be tested. The fit of Africa, North America, and South America is considered along with aspects of relative motion between North and South America since the early Jurasic. Attention is given to a framework for reconstructing Caribbean plate evolution, the evolution of the Caribbean, the plate boundary zones of the northern and southern Caribbean, and the active deformation of the Caribbean plate.

  7. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-05-06

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  8. Numerical modelling of instantaneous plate tectonics

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Haines, E.; Jordan, T. H.; Molnar, P.

    1974-01-01

    Assuming lithospheric plates to be rigid, 68 spreading rates, 62 fracture zones trends, and 106 earthquake slip vectors are systematically inverted to obtain a self-consistent model of instantaneous relative motions for eleven major plates. The inverse problem is linearized and solved iteratively by a maximum-likelihood procedure. Because the uncertainties in the data are small, Gaussian statistics are shown to be adequate. The use of a linear theory permits (1) the calculation of the uncertainties in the various angular velocity vectors caused by uncertainties in the data, and (2) quantitative examination of the distribution of information within the data set. The existence of a self-consistent model satisfying all the data is strong justification of the rigid plate assumption. Slow movement between North and South America is shown to be resolvable.

  9. Turbulent boundary layer over flexible plates

    NASA Astrophysics Data System (ADS)

    Rostami, Parand; Ioppolo, Tindaro

    2016-11-01

    This research describes the structure of a turbulent boundary layer flow with a zero pressure gradient over elastic plates. The elastic plates made of a thin aluminum sheets with thickness between 50 and 500 microns were placed on the floor of a subsonic wind tunnel and exposed to a turbulent boundary layer flow with a free stream velocity between 20m/s and 100m/s. The ceiling of the test section of the wind tunnel is adjustable so that a nearly zero pressure gradient is obtained in the test section. Hot-wire anemometry was used to measure the velocity components. Mean, fluctuating velocities and Reynolds stresses will be presented and compared with the values of a rigid plate.

  10. Plate tectonics drive tropical reef biodiversity dynamics

    PubMed Central

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  11. Dual fuel gradients in uranium silicide plates

    SciTech Connect

    Pace, B.W.

    1997-08-01

    Babcock & Wilcox has been able to achieve dual gradient plates with good repeatability in small lots of U{sub 3}Si{sub 2} plates. Improvements in homogeneity and other processing parameters and techniques have allowed the development of contoured fuel within the cladding. The most difficult obstacles to overcome have been the ability to evaluate the bidirectional fuel loadings in comparison to the perfect loading model and the different methods of instilling the gradients in the early compact stage. The overriding conclusion is that to control the contour of the fuel, a known relationship between the compact, the frames and final core gradient must exist. Therefore, further development in the creation and control of dual gradients in fuel plates will involve arriving at a plausible gradient requirement and building the correct model between the compact configuration and the final contoured loading requirements.

  12. [Biological monitoring in chromium-plating industry].

    PubMed

    Madsen, S W; Krue, S; Bonde, J P

    1992-05-25

    The purpose of the present investigation was to evaluate the role of biological monitoring as a means of surveillance of exposure in the Danish chromium-plating industry. We collected spot urine samples from 47 employees in five electro-plating plants near Aarhus and compared the results wide 40 non-exposed workers. We found no increase of chromium in urine during a work shift (mean = 0.11 nmol chromium/mmol creatinine, p = .46). The mean urine chromium value among the chromium workers was twice the mean value of the referent population (p = 0.001). There was, however, a considerable overlap between the two populations. All of the urine chromium values were much lower than the proposed American biological exposure indices. The results do not indicate any need for implementation of biological monitoring in the Danish chromium-plating industry, but longitudinal studies concerning possible accumulation of chromium at present occupational exposure levels should be carried out.

  13. Analysis of boiling flat-plate collectors

    SciTech Connect

    Price, H.W.; Klein, S.A.; Beckman, W.A.

    1986-05-01

    A detailed model for use with TRNSYS, capable of modelling a wide range of boiling collector types, was used to analyze boiling flat-plate collector systems. This model can account for a subcooled liquid entering the collector, heat losses in the vapor and the liquid return line, pressure drops due to friction in the collector and piping, and pressure drops due to the hydrostatic head of the fluid. The model has been used to determine the yearly performance of boiling flat-plate solar collector systems. A simplified approach was also developed which can be used with the f-Chart method to predict yearly performance of boiling flat-plate collector systems.

  14. Global Cretaceous plate tectonics and paleogeography

    SciTech Connect

    Barron, E.J.; Beeson, D.; Chen, P.; Dingle, R.V.; Frakes, L.A; Funnell, B.M.; Kauffman, E.G.; Petri, S.; Reyment, R.A.; Riccardi, A.C.

    1985-01-01

    The International Geologic Correlation Program (IGCP) Project 191, The Cretaceous Paleoclimatic Atlas Project has compiled 89 Cretaceous paleogeographic maps representing ten regions or continents. The map resolution varies from stage by stage (e.g. North America, Europe, USSR, Australia) to four maps (e.g. China, Southern South America) to a compilation of localities (Antarctica). The paleogeography is plotted here on global plate tectonic reconstructions for each stage. The reconstructions include continental positions and latitude. In addition, the oceanic plates are reconstructed including bathymetry based on a thermal age-depth relationship. The compiled paleogeography and plate tectonic base maps represent the most comprehensive framework for plotting and analyzing sedimentologic, geochemical and paleontologic data with respect to geography and latitude for the Cretaceous time period.

  15. Viscoelastic deformation near active plate boundaries

    NASA Technical Reports Server (NTRS)

    Ward, S. N.

    1986-01-01

    Model deformations near the active plate boundaries of Western North America using space-based geodetic measurements as constraints are discussed. The first six months of this project were spent gaining familarity with space-based measurements, accessing the Crustal Dynamics Data Information Computer, and building time independent deformation models. The initial goal was to see how well the simplest elastic models can reproduce very long base interferometry (VLBI) baseline data. From the Crustal Dynamics Data Information Service, a total of 18 VLBI baselines are available which have been surveyed on four or more occasions. These data were fed into weighted and unweighted inversions to obtain baseline closure rates. Four of the better quality lines are illustrated. The deformation model assumes that the observed baseline rates result from a combination of rigid plate tectonic motions plus a component resulting from elastic strain build up due to a failure of the plate boundary to slip at the full plate tectonic rate. The elastic deformation resulting from the locked plate boundary is meant to portray interseismic strain accumulation. During and shortly after a large interplate earthquake, these strains are largely released, and points near the fault which were previously retarded suddenly catch up to the positions predicted by rigid plate models. Researchers judge the quality of fit by the sum squares of weighted residuals, termed total variance. The observed baseline closures have a total variance of 99 (cm/y)squared. When the RM2 velocities are assumed to model the data, the total variance increases to 154 (cm/y)squared.

  16. Submuscular plating after distraction osteogenesis in children.

    PubMed

    Oh, Chang-Wug; Shetty, Gautam M; Song, Hae-Ryong; Kyung, Hee-Soo; Oh, Jong-Keon; Min, Woo-Kie; Lee, Byung-Woo; Park, Byung-Chul

    2008-09-01

    Although distraction osteogenesis has solved limb length discrepancies, many complications are inevitable from long duration of external fixation. Use of intramedullary nails for early removal of fixators has its own challenges especially in pediatric age group. To facilitate early removal of external fixators in children, we tried a novel method of submuscular plating over the distraction callus, which is described, and the results and complications of this technique are presented. In eight children (four girls and four boys), of limb lengthening (four cases) and bone transport (four cases) done in three femurs and five tibiae with external fixators (five Ilizarov ring fixators and three monofixators), submuscular plating was done over the distraction callus. The causes of limb length discrepancy included traumatic and septic growth arrest, congenital pseudoarthrosis of tibia, fibular hemimelia, tumor salvage, and Perthes' disease. The purpose of plating was to remove the external fixator earlier after achieving the target length. Mean age of plating procedure was 11.62 years, and mean amount of distraction was 5.47 cm. In all patients, the distraction callus healed on maintaining its length or correcting into the original alignment. The mean external fixation index was 26.93 days/cm and healing index was 52.01 days/cm. One complication of superficial pin-track infection occurred, which resolved completely with conservative treatment. None of the patients developed deep infection or implant failures. The mean follow-up after plating was 28 months (range, 18-62 months). Submuscular plating over the distraction callus may be a successful method that permits early removal of fixator with fewer complications. This method can be a useful alternative in children or when nailing is difficult.

  17. Finite stretching of an annular plate.

    NASA Technical Reports Server (NTRS)

    Biricikoglu, V.; Kalnins, A.

    1971-01-01

    The problem of the finite stretching of an annular plate which is bonded to a rigid inclusion at its inner edge is considered. The material is assumed to be isotropic and incompressible with a Mooney-type constitutive law. It is shown that the inclusion of the effect of the transverse normal strain leads to a rapid variation in thickness which is confined to a narrow edge zone. The explicit solutions to the boundary layer equations, which govern the behavior of the plate near the edges, are presented.

  18. Consensus on melanonychia nail plate dermoscopy*

    PubMed Central

    Chiacchio, Nilton Di; de Farias, Débora Cadore; Piraccini, Bianca Maria; Hirata, Sergio Henrique; Richert, Bertrand; Zaiac, Martin; Daniel, Ralph; Fanti, Pier Alessandro; Andre, Josette; Ruben, Beth S; Fleckman, Philip; Rich, Phoebe; Haneke, Eckart; Chang, Patricia; Cherit, Judith Dominguez; Scher, Richard; Tosti, Antonella

    2013-01-01

    This statement, focused on melanonychia and nail plate dermoscopy, is intended to guide medical professionals working with melanonychia and to assist choosing appropriate management for melanonychia patients. The International Study Group on Melanonychia was founded in 2007 and currently has 30 members, including nail experts and dermatopathologists with special expertise in nails. The need for common definitions of nail plate dermoscopy was addressed during the Second Meeting of this Group held in February 2008. Prior to this meeting and to date (2010) there have been no evidence-based guidelines on the use of dermoscopy in the management of nail pigmentation. PMID:23739699

  19. Optimal interaction of indenter with inhomogeneous plate

    NASA Technical Reports Server (NTRS)

    Aptukov, Valery N.

    1991-01-01

    Consideration is given to a new class of problems dealing with an optimal design of an inhomogeneous plate during dynamic penetration of the rigid indenter. The quality criterion of the process is defined by the specific mass of the target, which absorbs the given kinetic mass of the indenter. Parameters of control are expressed in terms of mechanical characteristics, i.e., distribution of density and the related hardness across the plate thickness. The maximum principle of Pontryagin is used to search for the piecewise continuous control function. With consideration of impact conditions and characteristics for a given class of material, an optimal target structure criterion was estimated for engineering applications.

  20. Plume impingement forces on inclined flat plates

    NASA Astrophysics Data System (ADS)

    Legge, H.

    Plume impingement from spacecraft control thrusters on vehicles in space is simulated in wind tunnel scale experiments. Pressure and shear stress are measured on flat plates inclined to the plume axis between 0 and 90 deg. In addition to a nozzle of a 0.5N thruster, a free jet from a thin plate orifice was used, by which the flow regime from nearly free molecular flow to continuum flow was covered. Simple pressure and shear stress laws are given by which the impingement pressure and shear stress can be estimated for engineering applications.

  1. Tomography, the geoid and plate motions

    SciTech Connect

    Gable, C.W.; O'connell, R.J. )

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period. 248 refs.

  2. Cascade impactor and jet plate for same

    DOEpatents

    Dahlin, Robert S.; Farthing, William E.; Landham Jr., Edward C.

    2004-02-03

    A sampling system and method for sampling particulate matter from a high-temperature, high-pressure gas stream. A cyclone sampler for use at high temperatures and pressures, and having threadless sacrificial connectors is disclosed. Also disclosed is an improved cascade impactor including jet plates with integral spacers, and alignment features provided for aligning the jet plates with their associated collection substrates. An activated bauxite alkali collector is disclosed, and includes an alumina liner. The sampling system can be operated remotely or locally, and can be permanently installed or configured as a portable system.

  3. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W [Livermore, CA

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  4. Simulating radiographic inspections with imaging plates

    NASA Astrophysics Data System (ADS)

    Yao, Min; Duvauchelle, Philippe; Kaftandjian, Valérie; Petersol-Parmentier, Angéla; Schumm, Andreas

    2016-02-01

    Computed Radiography (CR) based on photostimulable imaging plates (IP) is a potential replacement technique for traditional silver film radiography. For the inspections of components with high wall thicknesses requiring higher energy sources, however, imaging plate performance suffers from a spectral response which is low for the higher energies and high in the energy range where scattered radiation is typically observed. For these applications, care must be taken to apply appropriate filtering. Simulation tools are expected to be helpful in determining optimal operating conditions. We present a computer model which combines deterministic and Monte Carlo methods to simulate the imaging chain, focusing in particular on the scanner model.

  5. Seismology: tectonic strain in plate interiors?

    PubMed

    Calais, E; Mattioli, G; DeMets, C; Nocquet, J-M; Stein, S; Newman, A; Rydelek, P

    2005-12-15

    It is not fully understood how or why the inner areas of tectonic plates deform, leading to large, although infrequent, earthquakes. Smalley et al. offer a potential breakthrough by suggesting that surface deformation in the central United States accumulates at rates comparable to those across plate boundaries. However, we find no statistically significant deformation in three independent analyses of the data set used by Smalley et al., and conclude therefore that only the upper bounds of magnitude and repeat time for large earthquakes can be inferred at present.

  6. Characteristics of a microchannel plate intensifier

    NASA Technical Reports Server (NTRS)

    Sandie, W. G.; Mende, S. B.

    1982-01-01

    A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

  7. Spirit Beside 'Home Plate,' Sol 1809

    NASA Technical Reports Server (NTRS)

    2009-01-01

    NASA Mars Exploration Rover Spirit used its navigation camera to take the images assembled into this 120-degree view southward after a short drive during the 1,809th Martian day, or sol, of Spirit's mission on the surface of Mars (February 3, 2009).

    Spirit had driven about 2.6 meters (8.5 feet) that sol, continuing a clockwise route around a low plateau called 'Home Plate.' In this image, the rocks visible above the rovers' solar panels are on the slope at the northern edge of Home Plate.

    This view is presented as a cylindrical projection with geometric seam correction.

  8. Quality assurance in small plating shops

    SciTech Connect

    McNabb, W.J. )

    1993-10-01

    The potential for electroless nickel coatings in oilfield and petrochemical applications is quite high. The greatest obstacle to their use has been a reputation for poor quality due to a lack of quality control in many plating shops. To overcome this, electroless nickel shops should not only have a quality control program in their operation, but must also document its use and success. This article describes how a plating shoe can develop the necessary procedures, manuals, and paperwork trail to offer quality assurance and to satisfy customers.

  9. Imaging plates calibration to X-rays

    NASA Astrophysics Data System (ADS)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  10. Using plate mapping to examine sensitivity to plate size in food portions and meal composition among college students.

    PubMed

    Sharp, David; Sobal, Jeffery

    2012-12-01

    People eat meals rather than nutrients or food groups. Plate size may influence meal size, meal composition, and food type. To examine effects of plate size on meals, we developed a method we label plate mapping. A quasi-experimental study asked university students to accurately draw what they would like to eat for dinner on either a 9″ or 11″ paper plate. Coding plate drawings for total meal size revealed that students drew an average of 26% more food on larger plates. When plates were coded for meal composition we found that the biggest three food portions drawn by students were bigger on 11″ plates, with 70% of the overall difference in food area occurring in the biggest food. Participants drew bigger portions of vegetables on larger plates, while other food types showed little change in mean size. Gender moderated plate sensitivity for food types: women drew 36% bigger vegetable portions than men on larger plates. Smaller plates may lead to smaller meal sizes, but plate size may differentially influence composition of meals for men and women. These findings suggest plate mapping can be used to reflect meal conceptualizations and assess sensitivity to plate size.

  11. The stepped hybrid plate for carpal panarthrodesis - Part I: relationship between plate and bone surfaces.

    PubMed

    Diaz-Bertrana, C; Darnaculleta, F; Durall, I; Franch, J; Puchol, J L

    2009-01-01

    In the 1990s, the AO (Arbeitsgemeinschaft für Osteosynthesefragen) Hand Study Group developed several anatomically bent plates (standard and short) for wrist panarthrodesis in humans. However, only straight plates have been used for carpal panarthrodesis (CP) in animals to date. The primary purpose of this study was to determine if precontoured plates are more anatomical for CP in dogs. Measurement of several of the bones that are implicated in CP, as well as the relationship between their surfaces and the surface of a straight plate, were performed in a radiographic and computed tomographic cadaveric study. Axial and transverse measurements taken at different levels of the metacarpal bones 2, 3 and 4 were also included. The second objective of this study was to develop a more anatomical CP plate according to the results obtained. The measurements and images obtained in this study show that, as in human orthopaedics, bent or stepped plates are more anatomically correct than straight plates for CP in dogs.

  12. No-net-rotation model of current plate velocities incorporating plate motion model NUVEL-1

    NASA Technical Reports Server (NTRS)

    Argus, Donald F.; Gordon, Richard G.

    1991-01-01

    NNR-NUVEL1 is presented which is a model of plate velocities relative to the unique reference frame defined by requiring no-net-rotation of the lithosphere while constraining relative plate velocities to equal those in global plate motion model NUVEL-1 (DeMets et al., 1990). In NNR-NUVEL1, the Pacific plate rotates in a right-handed sense relative to the no-net-rotation reference frame at 0.67 deg/m.y. about 63 deg S, 107 deg E. At Hawaii the Pacific plate moves relative to the no-net-rotation reference frame at 70 mm/yr, which is 25 mm/yr slower than the Pacific plate moves relative to the hotspots. Differences between NNR-NUVEL1 and HS2-NUVEL1 are described. The no-net-rotation reference frame differs significantly from the hotspot reference frame. If the difference between reference frames is caused by motion of the hotspots relative to a mean-mantle reference frame, then hotspots beneath the Pacific plate move with coherent motion towards the east-southeast. Alternatively, the difference between reference frames can show that the uniform drag, no-net-torque reference frame, which is kinematically equivalent to the no-net-rotation reference frame, is based on a dynamically incorrect premise.

  13. A fluorescence-based coupling reaction for monitoring the activity of recombinant human NAD synthetase.

    PubMed

    Bembenek, Michael E; Kuhn, Eric; Mallender, William D; Pullen, Lester; Li, Ping; Parsons, Thomas

    2005-10-01

    NAD synthetase is responsible for the conversion of nicotinic acid adenine dinucleotide to nicotinamide adenine dinucleotide. This reaction provides a biosynthetic route of the coenzyme and, thus, a source of cellular reducing equivalents. Alterations in the oxidative reductive potential of the cell have been implicated as a contributing factor in many disease states. Thus, this enzyme represents a new class of potential drug targets, and, hence, our efforts were focused upon developing a robust assay for utilization in a high throughput screen. Toward that end, we describe a coupled enzyme assay format for the measurement of recombinant human NAD synthetase by employing lactate dehydrogenase in a cycling/amplification reaction linked ultimately to the fluorescence generation of resorufin from resazurin via diaphorase. We present kinetics of the reaction of NAD synthetase in the coupled assay format, optimization conditions, and inhibition of the reaction by gossypol [1,1',6,6',7,7'-hexahydroxy-3,3'-dimethyl-5,5'-bis(1-methylethyl)-[2,2'- binaphthalene]-8,8'-dicarboxaldehyde] and illustrate the robustness of the assay by demonstrating 384-well microtiter plate uniformity statistics. Collectively, our results show that the assay method is both robust and well suited for this class of enzymes involved in the NAD+ biosynthetic pathway.

  14. Instrumentation for continuous array genotyping of short insertion/deletion polymorphisms

    NASA Astrophysics Data System (ADS)

    Rusch, Terry L.; Dickinson, William; Che, Jian; Fieweger, Kim; Chudyk, Jon; Doktycz, Mitchel J.; Yu, Adong; Weber, James L.

    2003-07-01

    Methods for DNA testing are abundant, however, there is still a need for lower cost, higher-throughput genotyping. Much emphasis has been placed on short tandem repeat polymorphisms (STRPs) and single nucleotide polymorphisms (SNPs). Another important polymorphism is the diallelic short insertion/deletion (indel). Our laboratory is using a continuous reel of 384 well arrays on polypropylene tape to genotype indel polymorphisms. The reel of arrays allows low cost automation, and an opportunity to decrease reaction volumes. The diallelic indel is typed by tagging allele-specific PCR primers with a FAM or JOE molecular beacon uniprimer. Our most recent array pattern contains wells that hold a maximum of 1.1 microliters with reaction volumes of 800 nanoliters. Because micro array tape (microtape) is unique, commercial equipment is not yet available. A series of instruments were developed in-house to handle the tape. A pipetting instrument was developed to deliver the DNA samples or other reagents. A solenoid micro-valve aspirating and jetting unit was developed for dispensing a common reaction mix. The arrays are sealed with commercially available microtiter plate seal material prior to polymerase chain reaction (PCR) within a custom built waterbath thermal cycler. The arrays are scanned using an epi-fluorescence detection unit designed to read FAM and JOE fluorescent dyes. The detector uses an argon ion laser for excitation and two photomultiplier tubes (PMTs) for detection. The resulting images are processed using custom software.

  15. Construction and characterization of a bacterial artificial chromosome (BAC) library of Pacific white shrimp, Litopenaeus vannamei.

    PubMed

    Zhang, Xiaojun; Zhang, Yang; Scheuring, Chantel; Zhang, Hong-Bin; Huan, Pin; Wang, Bing; Liu, Chengzhang; Li, Fuhua; Liu, Bin; Xiang, Jianhai

    2010-04-01

    The pacific white shrimp (Litopenaeus vannamei) is one of the most economically important marine aquaculture species in the world. To facilitate gene cloning and characterization, genome analysis, physical mapping, and molecular selection breeding of marine shrimp, we have developed the techniques to isolate high-quality megabase-sized DNA from hemocyte nuclear DNA of female shrimp and constructed a bacterial artificial chromosome (BAC) genomic library for the species. The library was constructed in the Hind III site of the vector pECBAC1, consisting of 101,760 clones arrayed in 265 384-well microtiter plates, with an average insert size of 101 kb, and covering the genome approximately fivefold. To characterize the library, 92,160 clones were spotted onto high-density nylon filters for hybridization screening. A set of 18 pairs of overgo probes designed from eight cDNA sequences of L. vannamei genes were used in hybridization screening, and 35 positive clones were identified. These results suggest that the shrimp BAC libraries will provide a useful resource for screening of genomic regions of interest candidate genes, gene families, or large-sized synthetic DNA region and promote future works on comparative genomics, physical mapping, and large-scale genome sequencing in the species.

  16. Construction and characterization of a plant transformation-competent BIBAC library of the black Sigatoka-resistant banana Musa acuminata cv. Tuu Gia (AA).

    PubMed

    Ortiz-Vázquez, E; Kaemmer, D; Zhang, H-B; Muth, J; Rodríguez-Mendiola, M; Arias-Castro, C; James, Andrew

    2005-02-01

    A plant transformation-competent binary bacterial artificial chromosome (BIBAC) library was constructed from Musa acuminata cv. Tuu Gia (AA), a black Sigatoka-resistant diploid banana. After digestion of high-molecular-weight banana DNA by HindIII, several methods of DNA size selection were tested, followed by ligation, using a vector/insert molar ratio of 4:1. The library consists of 30,700 clones stored in 80 384-well microtiter plates. The mean insert size was estimated to be 100 kb, and the frequency of inserts with internal NotI sites was 61%. The majority of insert sizes fell into the range of 100+/-20 kb, making them suitable for Agrobacterium-mediated transformation. Only 1% and 0.9% of the clones contain chloroplast and mitochondrial DNA, respectively. This is the first BIBAC library for banana, estimated to represent five times its haploid genome (600 Mbp). It was demonstrated by hybridization that the library contains typical members of resistance gene and defense gene families that can be used for transformation of disease susceptible banana cultivars for banana genetic improvement.

  17. Targeted, haplotype-resolved resequencing of long segments of the human genome.

    PubMed

    Raymond, Christopher K; Subramanian, Sandhya; Paddock, Marcia; Qiu, Ruolan; Deodato, Chloe; Palmieri, Anthony; Chang, Jean; Radke, Tana; Haugen, Eric; Kas, Arnie; Waring, David; Bovee, Donald; Stacy, Robin; Kaul, Rajinder; Olson, Maynard V

    2005-12-01

    Currently, challenges exist to acquire long-range (hundreds of kilobase pairs) phase-discriminated sequence across substantial numbers of individuals. We have developed a straightforward method for isolating and characterizing specific genomic regions in a haplospecific manner. Real-time PCR is carried out to STS content map and genotype pools of fosmid clones arrayed in 384-well microtiter plates. Single-nucleotide polymorphisms, microsatellite markers, and insertion-deletion polymorphisms are used to differentiate the target region into haplotype-specific tiling paths. DNA of clones from these tiling paths is retrieved from the library and either sequenced by standard shotgun methods or amplified in vitro and sequenced by a primer-based, directed method. This approach provides convenient access to complete, haplotype-resolved resequencing data from multiple individuals across tens to hundreds of thousands of basepairs. We illustrate its implementation with a detailed example of more than 400 kbp from the human CFTR region, across 15 individuals, and summarize our experience applying it to many other human loci.

  18. Bendability of aluminiumand steel-clad chromium plates

    NASA Astrophysics Data System (ADS)

    Yoshida, Fusahito; Okada, Tatsuo; Itoh, Misao; Harada, Yasunori; Ohmori, Masanobu

    1998-05-01

    The present paper describes how the cladding of chromium plate with dissimilar metals improves the plastic bendability of the chromium. Three-point bending tests at various temperatures were performed for three types of chromium specimens: a monolithic chromium plate, aluminium- and steel-clad chromium plate. The aluminium-clad chromium plate was bent at 343 K up to a bent angle of 90 degrees without failure, even when the chromium layer was located outside of the plate (tension side), while the monolithic chromium plate could be bent exclusively at temperatures above 403 K. When the chromium layer was located inside of the steel-clad chromium plate (compression side), the plate was successfully bent at 307 K. The FE stress analysis of bending proved that the cladding of chromium plates with proper metals of different kinds is effective to reduce the tensile stress in chromium induced during bending and also the residual stress existing after bending operation.

  19. Stability of Three-Layered Annular Plate with Composite Facings

    NASA Astrophysics Data System (ADS)

    Pawlus, D.

    2017-02-01

    Paper presents the behaviour of three-layered annular plates subjected to loads acting in plate plane. Plates are composed of laminated fibre-reinforced composite facings and foam core. The static and dynamic parameters of plate critical state were evaluated. The sensitivity of composite structure of plate to the acting of quickly increasing in time loads is shown. The problem has been solved numerically using the finite element method. Results have been compared with ones obtained for plate models with isotropic layers. These plate models have also been calculated solving formulated task analytically and numerically by means of the finite difference method. Solutions to the problem concern the axisymmetrical and asymmetrical plate buckling modes. Numerous presented tables and figures create the image of the stability behaviour of examined composite plates.

  20. Stability of Three-Layered Annular Plate with Composite Facings

    NASA Astrophysics Data System (ADS)

    Pawlus, D.

    2016-10-01

    Paper presents the behaviour of three-layered annular plates subjected to loads acting in plate plane. Plates are composed of laminated fibre-reinforced composite facings and foam core. The static and dynamic parameters of plate critical state were evaluated. The sensitivity of composite structure of plate to the acting of quickly increasing in time loads is shown. The problem has been solved numerically using the finite element method. Results have been compared with ones obtained for plate models with isotropic layers. These plate models have also been calculated solving formulated task analytically and numerically by means of the finite difference method. Solutions to the problem concern the axisymmetrical and asymmetrical plate buckling modes. Numerous presented tables and figures create the image of the stability behaviour of examined composite plates.