Science.gov

Sample records for 384-well microtiter plate

  1. Reproducibility of Uniform Spheroid Formation in 384-Well Plates: The Effect of Medium Evaporation.

    PubMed

    Das, Viswanath; Fürst, Tomáš; Gurská, Soňa; Džubák, Petr; Hajdúch, Marián

    2016-10-01

    Spheroid cultures of cancer cells reproduce the spatial dimension-induced in vivo tumor traits more effectively than the conventional two-dimensional cell cultures. With growing interest in spheroids for high-throughput screening (HTS) assays, there is an increasing demand for cost-effective miniaturization of reproducible spheroids in microtiter plates (MPs). However, well-to-well variability in spheroid size, shape, and growth is a frequently encountered problem with almost every culture method that has prevented the transfer of spheroids to the HTS platform. This variability partly arises due to increased susceptibility of MPs to edge effects and evaporation-induced changes in the growth of spheroids. In this study, we examined the effect of evaporation on the reproducibility of spheroids of tumor and nontumor cell lines in 384-well plates, and show that culture conditions that prevent evaporation-induced medium loss result in the formation of uniform spheroids across the plate. Additionally, we also present a few technical improvements to increase the scalability of the liquid-overlay spheroid culturing technique in MPs, together with a simple software routine for the quantification of spheroid size. We believe that these cost-effective improvements will aid in further improvement of spheroid cultures for HTS drug discovery.

  2. Microscale 3D collagen cell culture assays in conventional flat-bottom 384-well plates.

    PubMed

    Leung, Brendan M; Moraes, Christopher; Cavnar, Stephen P; Luker, Kathryn E; Luker, Gary D; Takayama, Shuichi

    2015-04-01

    Three-dimensional (3D) culture systems such as cell-laden hydrogels are superior to standard two-dimensional (2D) monolayer cultures for many drug-screening applications. However, their adoption into high-throughput screening (HTS) has been lagging, in part because of the difficulty of incorporating these culture formats into existing robotic liquid handling and imaging infrastructures. Dispensing cell-laden prepolymer solutions into 2D well plates is a potential solution but typically requires large volumes of reagents to avoid evaporation during polymerization, which (1) increases costs, (2) makes drug penetration variable and (3) complicates imaging. Here we describe a technique to efficiently produce 3D microgels using automated liquid-handling systems and standard, nonpatterned, flat-bottomed, 384-well plates. Sub-millimeter-diameter, cell-laden collagen gels are deposited on the bottom of a ~2.5 mm diameter microwell with no concerns about evaporation or meniscus effects at the edges of wells, using aqueous two-phase system patterning. The microscale cell-laden collagen-gel constructs are readily imaged and readily penetrated by drugs. The cytotoxicity of chemotherapeutics was monitored by bioluminescence and demonstrated that 3D cultures confer chemoresistance as compared with similar 2D cultures. Hence, these data demonstrate the importance of culturing cells in 3D to obtain realistic cellular responses. Overall, this system provides a simple and inexpensive method for integrating 3D culture capability into existing HTS infrastructure. PMID:25510473

  3. A new platform for electrochemical analysis of a microtiter plate

    NASA Astrophysics Data System (ADS)

    Allen, Brian P.; Gilbert, Richard J.; Zhou, Xiao-Feng

    2004-12-01

    A disposable device is described for use in High Content Screening within the drug research process; it interfaces with a standard 384 well microtiter plate providing simultaneous full kinetic reaction data for a complete row of 24 wells. The device can be used in secondary screening for lead optimisation, for ADME (Absorption Distribution Metabolism and Excretion) assessment and toxicological assessment of candidate compounds. The device is a microfluidic unit and incorporates the necessary substrate and reaction chemicals. The microfluidic circuitry includes mixing paths, a reaction chamber, a single use valve and a waste reservoir as well as electrical measurement contacts. Movement of the fluids is provided by a single vacuum line which is distributed to all 24 separate cells. The device described incorporates a self-validation technique which provides a built in test facility.

  4. Microtiter plate-based antibody microarrays for bacteria and toxins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...

  5. 96-well microtiter plates for biofouling simulation in biomedical settings.

    PubMed

    Gomes, L C; Moreira, J M R; Teodósio, J S; Araújo, J D P; Miranda, J M; Simões, M; Melo, L F; Mergulhão, F J

    2014-01-01

    Microtiter plates with 96 wells are routinely used in biofilm research mainly because they enable high-throughput assays. These platforms are used in a variety of conditions ranging from static to dynamic operation using different shaking frequencies and orbital diameters. The main goals of this work were to assess the influence of nutrient concentration and flow conditions on biofilm formation by Escherichia coli in microtiter plates and to define the operational conditions to be used in order to simulate relevant biomedical scenarios. Assays were performed in static mode and in incubators with distinct orbital diameters using different concentrations of glucose, peptone and yeast extract. Computational fluid dynamics (CFD) was used to simulate the flow inside the wells for shaking frequencies ranging from 50 to 200 rpm and orbital diameters from 25 to 100 mm. Higher glucose concentrations enhanced adhesion of E. coli in the first 24 h, but variation in peptone and yeast extract concentration had no significant impact on biofilm formation. Numerical simulations indicate that 96-well microtiter plates can be used to simulate a variety of biomedical scenarios if the operating conditions are carefully set.

  6. Cavity-Enhanced Immunoassay Measurements in Microtiter Plates Using BBCEAS.

    PubMed

    Bajuszova, Zuzana; Ali, Zulfiqur; Scott, Simon; Seetohul, L Nitin; Islam, Meez

    2016-05-17

    We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, αmin(t), of 5.3 × 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests. PMID:27089516

  7. Microtiter plate tests for segregation of bioluminescent bacteria.

    PubMed

    Šimkus, Remigijus; Meškienė, Rita; Ledas, Žilvinas; Baronas, Romas; Meškys, Rolandas

    2016-02-01

    It has been recently shown that bioluminescence imaging can be usefully applied to provide new insights into bacterial self-organization. In this work we employ bioluminescence imaging to record images of nutrient rich liquid cultures of the lux-gene reporter Escherichia coli in microtiter plate wells. The images show that patterns of inhomogenous bioluminescence form along the three-phase contact lines. The paper analyzes the dependencies of the average number of luminous aggregates (clouds) on various environmental factors. In particular, our results show that optimal (neutral) pH and high aeration rates determine the highest mean number of clouds, and that spatiotemporal patterns do not form in the pH buffered suspensions. In addition, a sigmoidal (switch-like) dependence of the number of aggregates on the rate of aeration was observed. The obtained bioluminescence imaging data was interpreted by employing the Keller-Segel-Fisher (KSF) model of chemotaxis and logistic growth, adapted to systems of metabolically flexible (two-state) bacteria. The modified KSF model successfully simulated the observed switch-like responses. The results of the microtiter plate tests and their simulations indicate that the segregation of bacteria with different activities proceeds in the three-phase contact line region.

  8. Quantitative turbidity assay for lipolytic enzymes in microtiter plates.

    PubMed

    Barig, Susann; Schiemann, Manja; Mirsky, Vladimir M; Stahmann, K Peter

    2013-10-01

    A clearing assay for lipolytic enzymes has been realized in 96-well microtiter plates. A thin layer containing emulsified tributyrin as turbidity-generating substrate was placed on a thicker supporting aqueous layer. Both layers were stabilized by a gel-forming agent. Enzyme addition leads to clearing of the emulsion detected with a standard microtiter plate reader as a decrease of extinction. Dependencies of the signal kinetics on the substrate and enzyme concentrations were studied. For 0.5-1% tributyrin content the reaction rate is not substrate-limited. An initial slope of the signal kinetics is proportional to the lipase activity. A detailed characterization of the assay was performed. Lipolysis of tributyrin was confirmed by glycerol detection. Various gel-forming agents were compared and diffusion conditions in these gels were analyzed. Agar and agarose were found to be the most suitable gel-forming agents, which do not affect enzyme diffusion whereas polyacrylamide gels block lipase diffusion and therefore are not suitable for the assay. The optimized assay prepared from 1% tributyrin emulsion in 2% agar gel was tested with six microbial lipases and porcine pancreatic lipase. The detection limit is 20-60 ng/well which is equivalent to 30 μU/well for T. lanuginosus lipase.

  9. A modified microtiter-plate test for quantification of staphylococcal biofilm formation.

    PubMed

    Stepanovic, S; Vukovic, D; Dakic, I; Savic, B; Svabic-Vlahovic, M

    2000-04-01

    The tube test and the microtiter-plate test are the most frequently used techniques for quantifying biofilm formation, an important indicator for the pathogenicity of staphylococci. The purpose of the present study was to develop a modified microtiter-plate technique for quantification of biofilm formation. This technique involves fixing the bacterial film with methanol, staining with crystal violet, releasing the bound dye with 33% glacial acetic acid, and measuring the optical density (OD) of the solution at 570 nm by using an enzyme immunosorbent assay reader. Biofilm formation of 30 Staphylococcus strains was estimated by the tube test, the standard microtiter-plate test and the modified microtiter-plate test. The modified microtiter-plate test, as a quantitative assay, is superior to the tube test in terms of objectivity and accuracy. It is also superior to the standard microtiter-plate test because it enables indirect measuring of bacteria attached both to the bottom and to the walls of the wells, while in the standard test only the dye bound to the bacteria adhered to the bottom of the wells is spectrophotometrically registered. Highly significant differences between OD values obtained by the standard microtiter-plate test and those obtained by the modified test suggest that large number of bacteria were attached to the walls of the wells. Therefore, the modification of the standard microtiter-plate test by introduction of an additional step of decolorization by acetic acid seems to be a useful improvement of the technique.

  10. New lipase assay using Pomegranate oil coating in microtiter plates.

    PubMed

    Ülker, Serdar; Placidi, Camille; Point, Vanessa; Gadenne, Benoît; Serveau-Avesque, Carole; Canaan, Stéphane; Carrière, Frédéric; Cavalier, Jean-François

    2016-01-01

    Lipases play various roles in fat digestion, lipoprotein metabolism, and in the mobilization of fat stored in lipid bodies in animals, plants and microorganisms. In association with these physiological functions, there is an important field of research for discovering lipase inhibitors and developing new treatments of diseases such as obesity, atherosclerosis, diabetes and tuberculosis. In this context, the development of convenient, specific and sensitive analytical methods for the detection and assay of lipases and/or lipase inhibitors is of major importance. It is shown here that purified triacylglycerols (TAGs) from Punica granatum (Pomegranate) seed oil coated on microtiter plates can be used for the continuous assay of lipase activity by recording the variations with time of the UV absorption spectra at 275 nm. UV absorption is due the release of punicic acid (9Z,11E,13Z-octadeca-9,11,13-trienoic acid), a conjugated triene contained in Pomegranate oil. This new microtiter plate assay allows to accurately measure the activity of a wider range of lipases compared to the similar assay previously developed with Tung oil containing α-eleostearic acid (9Z,11E,13E-octadeca-9,11,13-trienoic acid), including the LipY lipase from Mycobacterium tuberculosis. Although punicic acid is a diastereoisomer of α-eleostearic acid, the Δ(13)cis double bound found in punicic acid gives a different structure to the acyl chain that probably favours the interaction of Pomegranate TAGs with the lipase active site. The microplate lipase assay using Pomegranate TAGs shows high sensitivity, reproducibility and remarkable relevance for the high-speed screening of lipases and/or lipase inhibitors directly from raw culture media without any purification step.

  11. New lipase assay using Pomegranate oil coating in microtiter plates.

    PubMed

    Ülker, Serdar; Placidi, Camille; Point, Vanessa; Gadenne, Benoît; Serveau-Avesque, Carole; Canaan, Stéphane; Carrière, Frédéric; Cavalier, Jean-François

    2016-01-01

    Lipases play various roles in fat digestion, lipoprotein metabolism, and in the mobilization of fat stored in lipid bodies in animals, plants and microorganisms. In association with these physiological functions, there is an important field of research for discovering lipase inhibitors and developing new treatments of diseases such as obesity, atherosclerosis, diabetes and tuberculosis. In this context, the development of convenient, specific and sensitive analytical methods for the detection and assay of lipases and/or lipase inhibitors is of major importance. It is shown here that purified triacylglycerols (TAGs) from Punica granatum (Pomegranate) seed oil coated on microtiter plates can be used for the continuous assay of lipase activity by recording the variations with time of the UV absorption spectra at 275 nm. UV absorption is due the release of punicic acid (9Z,11E,13Z-octadeca-9,11,13-trienoic acid), a conjugated triene contained in Pomegranate oil. This new microtiter plate assay allows to accurately measure the activity of a wider range of lipases compared to the similar assay previously developed with Tung oil containing α-eleostearic acid (9Z,11E,13E-octadeca-9,11,13-trienoic acid), including the LipY lipase from Mycobacterium tuberculosis. Although punicic acid is a diastereoisomer of α-eleostearic acid, the Δ(13)cis double bound found in punicic acid gives a different structure to the acyl chain that probably favours the interaction of Pomegranate TAGs with the lipase active site. The microplate lipase assay using Pomegranate TAGs shows high sensitivity, reproducibility and remarkable relevance for the high-speed screening of lipases and/or lipase inhibitors directly from raw culture media without any purification step. PMID:26343557

  12. Gas chromatography fractionation platform featuring parallel flame-ionization detection and continuous high-resolution analyte collection in 384-well plates.

    PubMed

    Jonker, Willem; Clarijs, Bas; de Witte, Susannah L; van Velzen, Martin; de Koning, Sjaak; Schaap, Jaap; Somsen, Govert W; Kool, Jeroen

    2016-09-01

    Gas chromatography (GC) is a superior separation technique for many compounds. However, fractionation of a GC eluate for analyte isolation and/or post-column off-line analysis is not straightforward, and existing platforms are limited in the number of fractions that can be collected. Moreover, aerosol formation may cause serious analyte losses. Previously, our group has developed a platform that resolved these limitations of GC fractionation by post-column infusion of a trap solvent prior to continuous small-volume fraction collection in a 96-wells plate (Pieke et al., 2013 [17]). Still, this GC fractionation set-up lacked a chemical detector for the on-line recording of chromatograms, and the introduction of trap solvent resulted in extensive peak broadening for late-eluting compounds. This paper reports advancements to the fractionation platform allowing flame ionization detection (FID) parallel to high-resolution collection of a full GC chromatograms in up to 384 nanofractions of 7s each. To this end, a post-column split was incorporated which directs part of the eluate towards FID. Furthermore, a solvent heating device was developed for stable delivery of preheated/vaporized trap solvent, which significantly reduced band broadening by post-column infusion. In order to achieve optimal analyte trapping, several solvents were tested at different flow rates. The repeatability of the optimized GC fraction collection process was assessed demonstrating the possibility of up-concentration of isolated analytes by repetitive analyses of the same sample. The feasibility of the improved GC fractionation platform for bioactivity screening of toxic compounds was studied by the analysis of a mixture of test pesticides, which after fractionation were subjected to a post-column acetylcholinesterase (AChE) assay. Fractions showing AChE inhibition could be unambiguously correlated with peaks from the parallel-recorded FID chromatogram. PMID:27485151

  13. Scale-down of vinegar production into microtiter plates using a custom-made lid.

    PubMed

    Schlepütz, Tino; Büchs, Jochen

    2014-04-01

    As an important food preservative and condiment, vinegar is widely produced in industry by submerged acetic acid bacteria cultures. Although vinegar production is established on the large scale, up to now suitable microscale cultivation methods, e.g. using microtiter plates, are missing to enable high-throughput cultivation and to optimize fermentation conditions. In order to minimize evaporation losses of ethanol and acetic acid in a 48-well microtiter plate during vinegar production a new custom-made lid was developed. A diffusion model was used to calculate the dimensions of a hole in the lid to guarantee a suitable oxygen supply and level of ventilation. Reference fermentation was conducted in a 9-L bioreactor to enable the calculation of the proper cultivation conditions in the microtiter plate. The minimum dissolved oxygen tensions in the microtiter plate were between 7.5% and 23% of air saturation and in the same range as in the 9-L bioreactor. Evaporation losses of ethanol and acetic acid were less than 5% after 47 h and considerably reduced compared to those of microtiter plate fermentations with a conventional gas-permeable seal. Furthermore, cultivation times in the microtiter plate were with about 40 h as long as in the 9-L bioreactor. In conclusion, microtiter plate cultivations with the new custom-made lid provide a platform for high-throughput studies on vinegar production. Results are comparable to those in the 9-L bioreactor.

  14. Microfluidic biolector-microfluidic bioprocess control in microtiter plates.

    PubMed

    Funke, Matthias; Buchenauer, Andreas; Schnakenberg, Uwe; Mokwa, Wilfried; Diederichs, Sylvia; Mertens, Alan; Müller, Carsten; Kensy, Frank; Büchs, Jochen

    2010-10-15

    In industrial-scale biotechnological processes, the active control of the pH-value combined with the controlled feeding of substrate solutions (fed-batch) is the standard strategy to cultivate both prokaryotic and eukaryotic cells. On the contrary, for small-scale cultivations, much simpler batch experiments with no process control are performed. This lack of process control often hinders researchers to scale-up and scale-down fermentation experiments, because the microbial metabolism and thereby the growth and production kinetics drastically changes depending on the cultivation strategy applied. While small-scale batches are typically performed highly parallel and in high throughput, large-scale cultivations demand sophisticated equipment for process control which is in most cases costly and difficult to handle. Currently, there is no technical system on the market that realizes simple process control in high throughput. The novel concept of a microfermentation system described in this work combines a fiber-optic online-monitoring device for microtiter plates (MTPs)--the BioLector technology--together with microfluidic control of cultivation processes in volumes below 1 mL. In the microfluidic chip, a micropump is integrated to realize distinct substrate flow rates during fed-batch cultivation in microscale. Hence, a cultivation system with several distinct advantages could be established: (1) high information output on a microscale; (2) many experiments can be performed in parallel and be automated using MTPs; (3) this system is user-friendly and can easily be transferred to a disposable single-use system. This article elucidates this new concept and illustrates applications in fermentations of Escherichia coli under pH-controlled and fed-batch conditions in shaken MTPs. PMID:20517981

  15. Efficient DNA sequencing on microtiter plates using dried reagents and Bst DNA polymerase.

    PubMed

    Earley, J J; Kuivaniemi, H; Prockop, D J; Tromp, G

    1993-01-01

    Sequenase, Taq DNA polymerase and Bst DNA polymerase were tested for sequencing of DNA on microtiter plates using dried down reagents. Several parameters were investigated to expedite the drying process while minimizing damage to the enzyme. Sequenase did not tolerate drying very well, and frequently generated sequences with weak signals and many sites of premature termination. With Taq DNA polymerase it was possible to obtain sequences of good quality. However, there was considerable variation of results between experiments and between batches of microtiter plates. Bst DNA polymerase generated sequences of excellent quality. It was stable for more than a week in dried-down state at -20 degrees C and at least overnight at room temperature. The method described here using Bst DNA polymerase is well suited for laboratory robots and workstations that typically employ 96-well microtiter plates. PMID:8173079

  16. Alteration of the aPA ELISA by UV exposure of polystyrene microtiter plates.

    PubMed

    Goldberg, J S; Wagenknecht, D R; McIntyre, J A

    1996-01-01

    Interlaboratory inconsistencies in antiphospholipid antibody (aPA) solid phase assays have prompted controversy in clinical laboratory testing for aPA. We found that the aPA ELISA can be influenced by the type of microtiter plate utilized and by the conditions in which the plates are stored. By exposing 96-well, flat-bottom polystyrene microtiter plates to short wave UV light (254 nm), the aPA ELISA signal decreased in a UV dose-dependent manner. No effect was seen with long wave UV light (366 nm). These results were independent of the antibody isotype under study or the phospholipid (PL) antigen used: anionic phosphatidylserine (PS) and cardiolipin (CL), or zwitterionic phosphatidylethanolamine (PE). Purified human beta 2-glycoprotein I (beta 2 GPI), a known cofactor for anionic PL, and rabbit anti-beta 2 GPI antisera were used to demonstrate that beta 2 GPI bound equally to UV treated and untreated microtiter plates. In contrast, recognition of beta 2 GPI on an anionic PL surface was decreased on UV treated plates, suggesting that UV exposure alters the lipid binding properties of the microliter plate. To determine whether UV exposure inhibited PL binding directly or caused a change in the way the PL was bound, the amount of PL bound to UV treated and untreated plates was measured by using fluorescent labeled PS and a fluorimeter. PS binding was decreased by 53% in UV treated wells as compared to untreated wells. These data show that short wave UV exposure reduces PL binding to polystyrene microtiter plates, thereby reducing the amount of beta 2 GPI bound to PL coated ELISA plates. Thus by using UV exposed microtiter plates, decreased or false-negative a PA ELISA results may be obtained for aPA positive plasmas. PMID:8887002

  17. Mitigation of microtiter plate positioning effects using a block randomization scheme.

    PubMed

    Roselle, Christopher; Verch, Thorsten; Shank-Retzlaff, Mary

    2016-06-01

    Microtiter plate-based assays are a common tool in biochemical and analytical labs. Despite widespread use, results generated in microtiter plate-based assays are often impacted by positional bias, in which variability in raw signal measurements are not uniform in all regions of the plate. Since small positional effects can disproportionately affect assay results and the reliability of the data, an effective mitigation strategy is critical. Commonly used mitigation strategies include avoiding the use of outer regions of the plate, replicating treatments within and between plates, and randomizing placement of treatments within and between plates. These strategies often introduce complexity while only partially mitigating positional effects and significantly reducing assay throughput. To reduce positional bias more effectively, we developed a novel block-randomized plate layout. Unlike a completely randomized layout, the block randomization scheme coordinates placement of specific curve regions into pre-defined blocks on the plate based on key experimental findings and assumptions about the distribution of assay bias and variability. Using the block-randomized plate layout, we demonstrated a mean bias reduction of relative potency estimates from 6.3 to 1.1 % in a sandwich enzyme-linked immunosorbent assay (ELISA) used for vaccine release. In addition, imprecision in relative potency estimates decreased from 10.2 to 4.5 % CV. Using simulations, we also demonstrated the impact of assay bias on measurement confidence and its relation to replication strategies. We outlined the underlying concepts of the block randomization scheme to potentially apply to other microtiter-based assays.

  18. Quantitative assay for mutation in diploid human lymphoblasts using microtiter plates

    SciTech Connect

    Furth, E.A.; Thilly, W.G.; Penman, B.W.; Liber, H.L.; Rand, W.M.

    1981-01-01

    A microtiter plating technique which eliminates the need for soft agar and fibroblast feeder layers to determine the colony-forming ability of diploid human lymphoblast lines was described. The calculation of cloning efficiency is based on the Poisson distribution, and a statistical method for calculating confidence intervals is presented. This technique has been applied to the comcomitant examination of induced mutation at the putative loci for hypoxanthine guanine phosphoribosyl transferase, thymidine, kinase, and Na/sup +//K/sup +/ adenosine triphosphatase.

  19. Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate.

    PubMed

    Felten, C; Foret, F; Minarik, M; Goetzinger, W; Karger, B L

    2001-04-01

    This paper describes the design and application of instrumentation for automated high-throughput infusion ESI-mass spectrometry. The approach, based on a subatmospheric ESI interface, allows sample introduction from a commercially available microtiter plate without the need for a separate fluid delivery system. The microtiter plate was placed vertically on a three-dimensional translation stage in front of the sampling ESI interface. A single, 7-cm, 20-microm-i.d. fused-silica capillary (total volume, 70 nL), with a tapered tip, served as a combination of sample delivery and spraying capillary. The tapered tip of the capillary was enclosed in a subatmospheric chamber attached in front of the orifice of the mass spectrometer. The sample aspiration rate (flow rate) was regulated by computer-controlled pneumatic valves, which allowed fast switching of the pressure in the subatmospheric ESI chamber. A flow-through wash device was positioned between the microtiter plate and the ESI interface. This design allowed alternate filling of the capillary with (a) sample from the wells and (b) wash solution from the wash device. Sample turnaround times of 10 s/sample, with a 120-nL sample consumption/analysis, and a duty cycle (percentage of total analysis time spent acquiring data) of 40% were achieved. The infusion system was demonstrated in the analysis of preparative HPLC fractions from a small molecule combinatorial library.

  20. Quantification of biofilm in microtiter plates: overview of testing conditions and practical recommendations for assessment of biofilm production by staphylococci.

    PubMed

    Stepanović, Srdjan; Vuković, Dragana; Hola, Veronika; Di Bonaventura, Giovanni; Djukić, Slobodanka; Cirković, Ivana; Ruzicka, Filip

    2007-08-01

    The details of all steps involved in the quantification of biofilm formation in microtiter plates are described. The presented protocol incorporates information on assessment of biofilm production by staphylococci, gained both by direct experience as well as by analysis of methods for assaying biofilm production. The obtained results should simplify quantification of biofilm formation in microtiter plates, and make it more reliable and comparable among different laboratories.

  1. Improvement and scale-down of a Trichoderma reesei shake flask protocol to microtiter plates enables high-throughput screening.

    PubMed

    Giese, Heiner; Kruithof, Paulien; Meier, Kristina; Sieben, Michaela; Antonov, Elena; Hommes, Ronald W J; Büchs, Jochen

    2014-12-01

    Nowadays, high-throughput screening is essential for determining the best microbial strains and fermentation conditions. Although microtiter plates allow higher throughput in screening than shake flasks, they do not guarantee sufficient oxygen supply if operated at unsuitable conditions. This is especially the case in viscous fermentations, potentially leading to poor liquid movement and surface growth. Therefore, in this study, two aims were pursued. First, an industrial Trichoderma reesei shake flask protocol is improved with respect to oxygen supply and production. Second, this improved shake flask protocol is scaled down into microtiter plate under consideration of similar oxygen supply. For this purpose, the respiration activity monitoring system (RAMOS) was applied. An approach based on a sulfite system was introduced to ensure equal maximum oxygen transfer capacities (OTRmax) in microtiter plates and shake flasks. OTRmax-values of 250 mL shake flasks and 24-well microtiter plates were determined in a wide range of operating conditions. These sulfite datasets were used to identify operating conditions leading to the same oxygen supply for T. reesei in shake flasks and 24-well microtiter plates. For 24-well microtiter plates, the shake flask OTRmax of 20 mmol/L/h of an industrial protocol was obtained under the following optimal operating conditions: 1 mL filling volume per well, 200 rpm shaking frequency and 50 mm shaking diameter. With these conditions almost identical oxygen transfer rates and product concentrations were measured in both scales. The proposed approach is a fast and accurate means to scale-down established screening procedures into microtiter plates to achieve high-throughput.

  2. Quantitative comparison between microfluidic and microtiter plate formats for cell-based assays.

    PubMed

    Yin, Huabing; Pattrick, Nicola; Zhang, Xunli; Klauke, Norbert; Cordingley, Hayley C; Haswell, Steven J; Cooper, Jonathan M

    2008-01-01

    In this paper, we compare a quantitative cell-based assay measuring the intracellular Ca2+ response to the agonist uridine 5'-triphosphate in Chinese hamster ovary cells, in both microfluidic and microtiter formats. The study demonstrates that, under appropriate hydrodynamic conditions, there is an excellent agreement between traditional well-plate assays and those obtained on-chip for both suspended immobilized cells and cultured adherent cells. We also demonstrate that the on-chip assay, using adherent cells, provides the possibility of faster screening protocols with the potential for resolving subcellular information about local Ca2+ flux.

  3. Newly designed and validated impedance spectroscopy setup in microtiter plates successfully monitors viable biomass online.

    PubMed

    Luchterhand, Bettina; Nolten, Jannis; Hafizovic, Sadik; Schlepütz, Tino; Wewetzer, Sandra Janine; Pach, Elke; Meier, Kristina; Wandrey, Georg; Büchs, Jochen

    2015-08-01

    In microtiter plates, conventional online monitoring of biomass concentration based on optical measurements is limited to transparent media: It also cannot differentiate between dead or viable biomass or suspended particles. To address this limitation, this study introduces and validates a new online monitoring setup based on impedance spectroscopy for detecting only viable biomass in 48- and 96-well microtiter plates. The setup was first validated electronically and characterized by determining the cell constants of the measuring geometry. Defined cell suspensions of Ustilago maydis, Hansenula polymorpha, Escherichia coli and Bacillus licheniformis were characterized to find, among other parameters, the most suitable frequency range and the characteristic frequency of β-dispersion for each organism. Finally, the setup was exemplarily applied to monitor the growth of Hansenula polymorpha online. As reference, three different parallel cultures were performed in established cultivation systems. This new online monitoring setup based on impedance spectroscopy is robust and enables precise measurements of microbial biomass concentration. It is promising for future high-throughput applications.

  4. Periodic acid-Schiff's reagent assay for carbohydrates in a microtiter plate format.

    PubMed

    Kilcoyne, Michelle; Gerlach, Jared Q; Farrell, Mark P; Bhavanandan, Veer P; Joshi, Lokesh

    2011-09-01

    Microtiter plate colorimetric assays are widely used for analysis of carbohydrates and glycoconjugates. However, mucins are often not easily detected, as they have low neutral sugar content. We have adapted and optimised the periodic acid-Schiff's reagent (PAS) staining for microtiter plate assay by examining five factors: concentration and volume of periodic acid, oxidation time, volume of Schiff's reagent, and color development time. This assay requires just 25 μl of sample, utilises standardised Schiff's reagent, and has decreased assay time (140 min to completion). Seventeen monosaccharides (acidic, neutral, basic, phosphorylated, and deoxy) and four disaccharides were assessed. PAS-positive carbohydrates (amino, N-acetylamino, deoxy, and certain neutral monosaccharides, and sialic acids) responded linearly within a 10-100 nmol range approximately, which varied for each carbohydrate. The assay response for fetuin and porcine gastric mucin (PGM) was linear up to 150 μg (highest concentration tested), with no response from nonglycosylated protein. A lower response for asialofetuin was observed, but desialylated PGM preparations were similar or higher in response than their sialylated counterparts. The simplicity and low sample consumption of this method make it an excellent choice for screening or quantitation of chromatographic fractions containing carbohydrates and glycoconjugates, especially in the case of mucins.

  5. Microtiter plates versus stirred mini-bioreactors in biocatalysis: a scalable approach.

    PubMed

    Nunes, Mário A P; Fernandes, Pedro C B; Ribeiro, Maria H L

    2013-05-01

    To place the application of miniaturized vessels as microbioreactors on a firm footing, focus has been given to engineering characterization. Studies on this matter have mostly involved carrier-free biological systems, while support-based systems have been overlooked. The present work aims to contribute to fill in such gap. Thus, it intended to establish a robust scaled down approach to identify and optimize relevant operational conditions of naringin hydrolysis by naringinase in PVA lens-shaped particles. The influence of geometric and dynamic (viz. Reynolds number) parameters was evaluated. Naringin hydrolysis in round, flat bottom MTP proved more effective than in square, pyramidal bottom. The bioconversion at MTP and stirred tank reactors scales showed that, given the 12.5-fold scale difference was in agreement between the bioconversion rates. The external mass transfer resistances were negligible as deduced from Damkohler modulus ≤1. The bioconversion was effectively scaled-up 200-fold from shaken microtiter plates to stirred tank reactors.

  6. Macroscale versus microscale methods for physiological analysis of biofilms formed in 96-well microtiter plates.

    PubMed

    Gomes, L C; Moreira, J M R; Miranda, J M; Simões, M; Melo, L F; Mergulhão, F J

    2013-12-01

    Microtiter plates with 96 wells have become one of the preferred platforms for biofilm studies mainly because they enable high-throughput assays. In this work, macroscale and microscale methods were used to study the impact of hydrodynamic conditions on the physiology and location of Escherichia coli JM109(DE3) biofilms formed in microtiter plates. Biofilms were formed in shaking and static conditions, and two macroscale parameters were assayed: the total amount of biofilm was measured by the crystal violet assay and the metabolic activity was determined by the resazurin assay. From the macroscale point of view, there were no statistically significant differences between the biofilms formed in static and shaking conditions. However, at a microscale level, the differences between both conditions were revealed using scanning electron microscopy (SEM). It was observed that biofilm morphology and spatial distribution along the wall were different in these conditions. Simulation of the hydrodynamic conditions inside the wells at a microscale was performed by computational fluid dynamics (CFD). These simulations showed that the shear strain rate was unevenly distributed on the walls during shaking conditions and that regions of higher shear strain rate were obtained closer to the air/liquid interface. Additionally, it was shown that wall regions subjected to higher shear strain rates were associated with the formation of biofilms containing cells of smaller size. Conversely, regions with lower shear strain rate were prone to have a more uniform spatial distribution of adhered cells of larger size. The results presented on this work highlight the wealth of information that may be gathered by complementing macroscale approaches with a microscale analysis of the experiments. PMID:24140575

  7. Optimization of Salmonella Typhi biofilm assay on polypropylene microtiter plates using response surface methodology.

    PubMed

    Ganjali Dashti, M; Abdeshahian, P; Sudesh, K; Phua, K K

    2016-01-01

    The objective of this study was to develop an optimized assay for Salmonella Typhi biofilm that mimics the environment of the gallbladder as an experimental model for chronic typhoid fever. Multi-factorial assays are difficult to optimize using traditional one-factor-at-a-time optimization methods. Response surface methodology (RSM) was used to optimize six key variables involved in S. Typhi biofilm formation on cholesterol-coated polypropylene 96-well microtiter plates. The results showed that bile (1.22%), glucose (2%), cholesterol (0.05%) and potassium chloride (0.25%) were critical factors affecting the amount of biofilm produced, but agitation (275 rpm) and sodium chloride (0.5%) had antagonistic effects on each other. Under these optimum conditions the maximum OD reading for biofilm formation was 3.4 (λ600 nm), and the coefficients of variation for intra-plate and inter-plate assays were 3% (n = 20) and 5% (n = 8), respectively. These results showed that RSM is an effective approach for biofilm assay optimization. PMID:26963754

  8. Surface-activated microtiter-plate microarray for simultaneous CRP quantification and viral antibody detection.

    PubMed

    Viitala, Sari M; Jääskeläinen, Anne J; Kelo, Eira; Sirola, Helena; Moilanen, Kirsi; Suni, Jukka; Vaheri, Antti; Vapalahti, Olli; Närvänen, Ale

    2013-02-01

    Microarrays are widely used in high-throughput DNA and RNA hybridization tests and recently adopted to protein and small molecule interaction studies in basic research and diagnostics. Parallel detection of serum antibodies and antigens has several potential applications in epidemiologic research, vaccine development, and in the diagnosis of allergies, autoimmunity, and infectious diseases. This study demonstrates an immobilization method for immunoassay-based microarray in conventional 96-well polystyrene plates for a serologic diagnostic method combined with quantitative C-reactive protein (CRP) assay. A synthetic peptide (HIV-1), a recombinant protein (Puumala hantavirus nucleocapsid), and purified virus preparations (Sindbis and adenoviruses) were used as antigens for virus-specific antibody detection and monoclonal anti-CRP antibody for antigen detection. The microarray was based on conventional enzyme immunoassays and densitometry from photographed results. Peptide and recombinant antigens functioned well, while whole virus antigens gave discrepant results in 1 out of 23 samples from the reference method, tested with human sera with various antibody responses. The CRP results were in concordance in the concentration range 0.5-150 mg/L with 2 commercially available CRP assays: ReaScan rapid test (R(2) = 0.9975) and Cobas 6000 analyzer (R(2) =0.9595). The results indicate that microtiter plates provide a promising platform for further development of microarrays for parallel antibody and antigen detection. PMID:23219230

  9. A chemiluminescent microtiter plate assay for sensitive detection of protein kinase activity.

    PubMed

    Lehel, C; Daniel-Issakani, S; Brasseur, M; Strulovici, B

    1997-01-15

    A chemiluminescent protein kinase assay using biotinylated substrate peptides captured on a streptavidin-coated microtiter plate and monoclonal antibodies to detect their phosphorylation is described. Assay conditions were optimized and validated for sensitive measurement of protein kinase A, protein kinase C, Ca2+/calmodulin-dependent protein kinase II (CAM-KII), receptor interacting protein, and src activities. The newly developed chemiluminescent assay has several advantages over currently used radioactive or colorimetric methods. It is highly sensitive at low enzyme and substrate concentrations and high, close to physiological ATP levels. It is fast, simple to perform and amenable to automation and high-throughput drug screening. The assay is also robust, exhibiting minimum interference from solvents and test substances from various sources. Overall, among the presently available methods for the detection of protein kinase activity, chemiluminescence was found to provide the highest sensitivity under conditions most closely mimicking the intracellular environment. This assay is expected to be useful in both academic and industrial laboratories, especially in identifying novel classes of protein kinase inhibitors.

  10. Colorimetric determination of fructose for the high-throughput microtiter plate assay of glucose isomerase.

    PubMed

    Katano, Hajime; Takakuwa, Masahiro; Itoh, Takafumi; Hibi, Takao

    2015-01-01

    A colorimetric method for the reducing monosaccharide determination is optimized for the assay of glucose isomerase, which converts glucose (Glc) to fructose (Fru). Test solution was mixed with 20-fold volume of the 50 mM Na2SiO3, 600 mM Na2MoO4, and 0.95 M HCl aqueous solution (pH 4.5), in which a yellow molybdosilicate species was formed. The mixture was kept at 70 °C for 30 min. Test solution containing 10 mM level Fru gave a remarkable blue reaction mixture, in which the Mo(VI) species was reduced by Fru to form a blue molybdosilicate species. The blueness increased with the Fru concentration. Glc cannot render the reaction mixture blue as strong as Fru. Thus, the colorimetric method can be used advantageously for the determination of 10 mM level Fru in the Glc isomerase reaction mixture, even in the presence of 100 mM level Glc, and has been applied successfully to the microtiter plate assay of the enzyme.

  11. Determination of sugar specificity of jackfruit lectin by a simple sugar-lectin binding assay using microtiter plate.

    PubMed

    Wetprasit, N; Chulavatnatol, M

    1997-06-01

    Sugar-lectin binding assay was developed as a simple method which employed direct coating of microtiter plate with galactose-binding lectins. Biotin-galactose conjugate was used to bind to the immobilized lectins. The bound conjugate was then detected using streptavidin-horseradish peroxidase. Using the assay in conjunction with various competing carbohydrates, jackfruit lectin from Artocarpus heterophyllus was found to be specific for alpha-anomer of galactoside with an aromatic residue.

  12. Evaluation of blood agar microtiter plates for culturing leishmania parasites to titrate parasite burden in spleen and peripheral blood of patients with visceral leishmaniasis.

    PubMed

    Maurya, Radheshyam; Mehrotra, Sanjana; Prajapati, Vijay Kumar; Nylén, Susanne; Sacks, David; Sundar, Shyam

    2010-05-01

    Serial dilution of blood and spleen biopsy specimens, plated on Novy-MacNeal-Nicolle (NNN) blood agar using microtiter culture plates, is a sensitive and reproducible method for detection and growth of Leishmania parasites. Plates could be easily monitored, and growth could be rapidly detected. Moreover, parasite number may be estimated using this technique.

  13. Development of a high-throughput assay for measuring lipase activity using natural triacylglycerols coated on microtiter plates.

    PubMed

    Serveau-Avesque, Carole; Verger, Robert; Rodriguez, Jorge A; Abousalham, Abdelkarim

    2013-09-21

    We have designed a convenient, specific, sensitive and continuous lipase assay based on the use of natural triacylglycerols (TAGs) from the Aleurites fordii seed oil which contains α-eleostearic acid (9,11,13,cis,trans,trans-octadecatrienoic acid) and which was coated in the wells of microtiter plates. The coated TAG film cannot be desorbed by the various buffers used during the lipase assay. Upon lipase action, α-eleostearic acid is liberated and desorbed from the interface and then solubilized into the micellar phase. Consequently, the UV absorbance of the α-eleostearic acid is considerably enhanced due to the transformation from an adsorbed to a water soluble state. The lipase activity can be measured continuously by recording the variations with time of the UV absorption spectra. The rate of lipolysis was monitored by measuring the increase of OD at 272 nm, which was found to be linear with time and directly proportional to the amount of added lipase. This microtiter plate lipase assay, based on coated TAGs, presents various advantages as compared to the classical systems: (i) coated TAGs on the microtiter plates could be stored for a long-time at 4 °C, (ii) higher sensitivity in lipase detection, (iii) good reproducibility, and (iv) increase of signal to noise ratio due to high UV absorption after transfer of α-eleostearic acid from an adsorbed to a soluble state. Low concentrations, down to 1 pg mL(-1) of pure Thermomyces lanuginosus or human pancreatic lipase, could be detected under standard assay conditions. The detection sensitivity of this coated method is around 1000 times higher as compared to those obtained with the classical emulsified systems. This continuous high throughput lipase assay could be used to screen new lipases and/or lipase inhibitors present in various biological samples.

  14. Immobilization of saccharides and peptides on 96-well microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer.

    PubMed

    Satoh, A; Kojima, K; Koyama, T; Ogawa, H; Matsumoto, I

    1998-06-15

    We have previously reported a method to immobilize protein ligands on microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) [Isosaki, K., et al. (1992) J. Chromatogr. 597, 123-128]. In this study, we improved the MMAC method to efficiently immobilize not only small ligands such as peptides and oligosaccharides, which could not be efficiently immobilized previously, but also heparin via its reducing end. Amino and hydrazino groups were introduced to MMAC-coated microtiter plate wells by coupling to acid anhydride groups of MMAC with 1,6-hexamethylenediamine and adipic acid dihydrazide, respectively. The amino groups introduced were allowed to react with peptides by use of divalent cross-linkers. Hydrazino groups were allowed to react with formyl groups of saccharides by reductive amination. Peptides and oligosaccharides were immobilized in a dose-dependent manner by these methods. In the case of the angiotensin peptide thus immobilized, the detection limit by monoclonal antibodies was as low as 0.1-1 fmol peptide per well. Application of 20-200 nmol oligosaccharides to the well was sufficient to immobilize and subsequently detect lectins. Furthermore, heparin immobilized on the hydrazinocoated wells was successfully used for the binding assay of annexin IV. PMID:9648659

  15. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution. PMID:24260173

  16. A high-throughput microtiter plate based method for the determination of peracetic acid and hydrogen peroxide.

    PubMed

    Putt, Karson S; Pugh, Randall B

    2013-01-01

    Peracetic acid is gaining usage in numerous industries who have found a myriad of uses for its antimicrobial activity. However, rapid high throughput quantitation methods for peracetic acid and hydrogen peroxide are lacking. Herein, we describe the development of a high-throughput microtiter plate based assay based upon the well known and trusted titration chemical reactions. The adaptation of these titration chemistries to rapid plate based absorbance methods for the sequential determination of hydrogen peroxide specifically and the total amount of peroxides present in solution are described. The results of these methods were compared to those of a standard titration and found to be in good agreement. Additionally, the utility of the developed method is demonstrated through the generation of degradation curves of both peracetic acid and hydrogen peroxide in a mixed solution.

  17. Cross-section perimeter is a suitable parameter to describe the effects of different baffle geometries in shaken microtiter plates

    PubMed Central

    2014-01-01

    Background Biotechnological screening processes are performed since more than 8 decades in small scale shaken bioreactors like shake flasks or microtiter plates. One of the major issues of such reactors is the sufficient oxygen supply of suspended microorganisms. Oxygen transfer into the bulk liquid can in general be increased by introducing suitable baffles at the reactor wall. However, a comprehensive and systematic characterization of baffled shaken bioreactors has never been carried out so far. Baffles often differ in number, size and shape. The exact geometry of baffles in glass lab ware like shake flasks is very difficult to reproduce from piece to piece due to the hard to control flow behavior of molten glass during manufacturing. Thus, reproducibility of the maximum oxygen transfer capacity in such baffled shake flasks is hardly given. Results As a first step to systematically elucidate the general effect of different baffle geometries on shaken bioreactor performance, the maximum oxygen transfer capacity (OTRmax) in baffled 48-well microtiter plates as shaken model reactor was characterized. This type of bioreactor made of plastic material was chosen, as the exact geometry of the baffles can be fabricated by highly reproducible laser cutting. As a result, thirty different geometries were investigated regarding their maximum oxygen transfer capacity (OTRmax) and liquid distribution during shaking. The relative perimeter of the cross-section area as new fundamental geometric key parameter is introduced. An empirical correlation for the OTRmax as function of the relative perimeter, shaking frequency and filling volume is derived. For the first time, this correlation allows a systematic description of the maximum oxygen transfer capacity in baffled microtiter plates. Conclusions Calculated and experimentally determined OTRmax values agree within ± 30% accuracy. Furthermore, undesired out-of-phase operating conditions can be identified by using the

  18. Robo-Lector – a novel platform for automated high-throughput cultivations in microtiter plates with high information content

    PubMed Central

    Huber, Robert; Ritter, Daniel; Hering, Till; Hillmer, Anne-Kathrin; Kensy, Frank; Müller, Carsten; Wang, Le; Büchs, Jochen

    2009-01-01

    Background In industry and academic research, there is an increasing demand for flexible automated microfermentation platforms with advanced sensing technology. However, up to now, conventional platforms cannot generate continuous data in high-throughput cultivations, in particular for monitoring biomass and fluorescent proteins. Furthermore, microfermentation platforms are needed that can easily combine cost-effective, disposable microbioreactors with downstream processing and analytical assays. Results To meet this demand, a novel automated microfermentation platform consisting of a BioLector and a liquid-handling robot (Robo-Lector) was sucessfully built and tested. The BioLector provides a cultivation system that is able to permanently monitor microbial growth and the fluorescence of reporter proteins under defined conditions in microtiter plates. Three examplary methods were programed on the Robo-Lector platform to study in detail high-throughput cultivation processes and especially recombinant protein expression. The host/vector system E. coli BL21(DE3) pRhotHi-2-EcFbFP, expressing the fluorescence protein EcFbFP, was hereby investigated. With the method 'induction profiling' it was possible to conduct 96 different induction experiments (varying inducer concentrations from 0 to 1.5 mM IPTG at 8 different induction times) simultaneously in an automated way. The method 'biomass-specific induction' allowed to automatically induce cultures with different growth kinetics in a microtiter plate at the same biomass concentration, which resulted in a relative standard deviation of the EcFbFP production of only ± 7%. The third method 'biomass-specific replication' enabled to generate equal initial biomass concentrations in main cultures from precultures with different growth kinetics. This was realized by automatically transferring an appropiate inoculum volume from the different preculture microtiter wells to respective wells of the main culture plate, where

  19. Evaluation of microtiter-plate enzyme-linked immunosorbent assay for the analysis of triazine and chloroacetanilide herbicides in rainfall

    USGS Publications Warehouse

    Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.

    1998-01-01

    Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive

  20. An Immunoassay for Dibutyl Phthalate Based on Direct Hapten Linkage to the Polystyrene Surface of Microtiter Plates

    PubMed Central

    Wei, Chenxi; Ding, Shumao; You, Huihui; Zhang, Yaran; Wang, Yao; Yang, Xu; Yuan, Junlin

    2011-01-01

    Background Dibutyl phthalate (DBP) is predominantly used as a plasticizer inplastics to make them flexible. Extensive use of phthalates in both industrial processes and other consumer products has resulted in the ubiquitous presence of phthalates in the environment. In order to better determine the level of pollution in the environment and evaluate the potential adverse effects of exposure to DBP, immunoassay for DBP was developed. Methodology/Principal Findings A monoclonal antibody specific to DBP was produced from a stable hybridoma cell line generated by lymphocyte hybridoma technique. An indirect competitive enzyme-linked immunosorbent assay (icELISA) employing direct coating of hapten on polystyrene microtiter plates was established for the detection of DBP. Polystyrene surface was first oxidized by permanganate in dilute sulfuric acid to generate carboxyl groups. Then dibutyl 4-aminophthalate, which is an analogue of DBP, was covalently linked to the carboxyl groups of polystyrene surface with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC). Compared with conjugate coated format (IC50 = 106 ng/mL), the direct hapten coated format (IC50 = 14.6 ng/mL) improved assay sensitivity after careful optimization of assay conditions. The average recovery of DBP from spiked water sample was 104.4% and the average coefficient of variation was 9.95%. Good agreement of the results obtained by the hapten coated icELISA and gas chromatography-mass spectrometry further confirmed the reliability and accuracy of the icELISA for the detection of DBP in certain plastic and cosmetic samples. Conclusions/Significance The stable and efficient hybridoma cell line obtained is an unlimited source of sensitive and specific antibody to DBP. The hapten coated format is proposed as generally applicable because the carboxyl groups on modified microtiter plate surface enables stable immobilization of aminated or hydroxylated hapten with EDC. The developed hapten

  1. Development of resazurin-based assay in 384-well format for high throughput whole cell screening of Trypanosoma brucei rhodesiense strain STIB 900 for the identification of potential anti-trypanosomal agents.

    PubMed

    Lim, Kah Tee; Zahari, Zuriati; Amanah, Azimah; Zainuddin, Zafarina; Adenan, Mohd Ilham

    2016-03-01

    To accelerate the discovery of novel leads for the treatment of Human African Trypanosomiasis (HAT), it is necessary to have a simple, robust and cost-effective assay to identify positive hits by high throughput whole cell screening. Most of the fluorescence assay was made in black plate however in this study the HTS assay developed in 384-well format using clear plate and black plate, for comparison. The HTS assay developed is simple, sensitive, reliable and reproducible in both types of plates. Assay robustness and reproducibility were determined under the optimized conditions in 384-well plate was well tolerated in the HTS assay, including percentage of coefficient of variation (% CV) of 4.68% and 4.74% in clear and black 384-well plate, signal-to-background ratio (S/B) of 12.75 in clear 384-well plate and 12.07 in black 384-well plate, Z' factor of 0.79 and 0.82 in clear 384-well plate and black 384-well plate, respectively and final concentration of 0.30% dimethylsulfoxide (DMSO) in both types of plate. Drug sensitivity was found to be comparable to the reported anti-trypanosomal assay in 96-well format. The reproducibility and sensitivity of this assay make it compliant to automated liquid handler use in HTS applications. PMID:26772786

  2. Development of resazurin-based assay in 384-well format for high throughput whole cell screening of Trypanosoma brucei rhodesiense strain STIB 900 for the identification of potential anti-trypanosomal agents.

    PubMed

    Lim, Kah Tee; Zahari, Zuriati; Amanah, Azimah; Zainuddin, Zafarina; Adenan, Mohd Ilham

    2016-03-01

    To accelerate the discovery of novel leads for the treatment of Human African Trypanosomiasis (HAT), it is necessary to have a simple, robust and cost-effective assay to identify positive hits by high throughput whole cell screening. Most of the fluorescence assay was made in black plate however in this study the HTS assay developed in 384-well format using clear plate and black plate, for comparison. The HTS assay developed is simple, sensitive, reliable and reproducible in both types of plates. Assay robustness and reproducibility were determined under the optimized conditions in 384-well plate was well tolerated in the HTS assay, including percentage of coefficient of variation (% CV) of 4.68% and 4.74% in clear and black 384-well plate, signal-to-background ratio (S/B) of 12.75 in clear 384-well plate and 12.07 in black 384-well plate, Z' factor of 0.79 and 0.82 in clear 384-well plate and black 384-well plate, respectively and final concentration of 0.30% dimethylsulfoxide (DMSO) in both types of plate. Drug sensitivity was found to be comparable to the reported anti-trypanosomal assay in 96-well format. The reproducibility and sensitivity of this assay make it compliant to automated liquid handler use in HTS applications.

  3. Colorimetric microtiter plate receptor-binding assay for the detection of freshwater and marine neurotoxins targeting the nicotinic acetylcholine receptors

    USGS Publications Warehouse

    Rubio, Fernando; Kamp, Lisa; Carpino, Justin; Faltin, Erin; Loftin, Keith A.; Molgó, Jordi; Aráoz, Rómulo

    2014-01-01

    Anatoxin-a and homoanatoxin-a, produced by cyanobacteria, are agonists of nicotinic acetylcholine receptors (nAChRs). Pinnatoxins, spirolides, and gymnodimines, produced by dinoflagellates, are antagonists of nAChRs. In this study we describe the development and validation of a competitive colorimetric, high throughput functional assay based on the mechanism of action of freshwater and marine toxins against nAChRs. Torpedo electrocyte membranes (rich in muscle-type nAChR) were immobilized and stabilized on the surface of 96-well microtiter plates. Biotinylated α-bungarotoxin (the tracer) and streptavidin-horseradish peroxidase (the detector) enabled the detection and quantitation of anatoxin-a in surface waters and cyclic imine toxins in shellfish extracts that were obtained from different locations across the US. The method compares favorably to LC/MS/MS and provides accurate results for anatoxin-a and cyclic imine toxins monitoring. Study of common constituents at the concentrations normally found in drinking and environmental waters, as well as the tolerance to pH, salt, solvents, organic and inorganic compounds did not significantly affect toxin detection. The assay allowed the simultaneous analysis of up to 25 samples within 3.5 h and it is well suited for on-site or laboratory monitoring of low levels of toxins in drinking, surface, and ground water as well as in shellfish extracts.

  4. Convenient microtiter plate-based, oxygen-independent activity assays for flavin-dependent oxidoreductases based on different redox dyes.

    PubMed

    Brugger, Dagmar; Krondorfer, Iris; Zahma, Kawah; Stoisser, Thomas; Bolivar, Juan M; Nidetzky, Bernd; Peterbauer, Clemens K; Haltrich, Dietmar

    2014-04-01

    Flavin-dependent oxidoreductases are increasingly recognized as important biocatalysts for various industrial applications. In order to identify novel activities and to improve these enzymes in engineering approaches, suitable screening methods are necessary. We developed novel microtiter-plate-based assays for flavin-dependent oxidases and dehydrogenases using redox dyes as electron acceptors for these enzymes. 2,6-dichlorophenol-indophenol, methylene green, and thionine show absorption changes between their oxidized and reduced forms in the visible range, making it easy to judge visually changes in activity. A sample set of enzymes containing both flavoprotein oxidases and dehydrogenases - pyranose 2-oxidase, pyranose dehydrogenase, cellobiose dehydrogenase, D-amino acid oxidase, and L-lactate oxidase - was selected. Assays for these enzymes are based on a direct enzymatic reduction of the redox dyes and not on the coupled detection of a reaction product as in the frequently used assays based on hydrogen peroxide formation. The different flavoproteins show low Michaelis constants with these electron acceptor substrates, and therefore these dyes need to be added in only low concentrations to assure substrate saturation. In conclusion, these electron acceptors are useful in selective, reliable and cheap MTP-based screening assays for a range of flavin-dependent oxidoreductases, and offer a robust method for library screening, which could find applications in enzyme engineering programs. PMID:24376171

  5. A method combining immunocapture and PCR amplification in a microtiter plate for the detection of plant viruses and subviral pathogens.

    PubMed

    Nolasco, G; de Blas, C; Torres, V; Ponz, F

    1993-12-15

    A method for the detection of RNA viral and subviral plant pathogens was developed that combines pathogen partial purification by solid-phase adsorbed antibodies, reverse transcriptional-polymerase chain reaction (RT-PCR) and quantitation of the amplified products by fluorescence. The reverse transcription of the RNA is performed directly on the retained material without any previous thermal or chemical disruption of the virus particles. The whole procedure can be carried out in a microtiter plate. Its validity has been successfully confirmed for the detection of bean yellow mosaic virus, cherry leafroll virus, cucumber mosaic virus, citrus tristeza virus, grapevine fanleaf virus, potato leafroll virus, pepper mild mottle virus, and tomato spotted wilt virus, as well as the satellite RNA of cucumber mosaic virus and potato spindle tuber viroid. In this procedure virus-specific antibodies can be replaced by monoclonal antibodies against double-stranded RNA, thus offering the possibility of detection when no specific virus antibodies are available, or immunological methods are difficult to use (i.e., subviral pathogens like satellite-RNAs or viroids). The method described has the typical sensitivity of assays based on the polymerase chain reaction, it is not more laborious than ELISA, and an equivalent degree of automation is possible. PMID:8113346

  6. A functional dual-coated (FDC) microtiter plate method to replace the botulinum toxin LD50 test.

    PubMed

    Liu, Yvonne Y B; Rigsby, Peter; Sesardic, Dorothea; Marks, James D; Jones, Russell G A

    2012-06-01

    Conventional capture ("Sandwich") ELISAs equally detect denatured inactive and native active botulinum type A toxin. Light chain endoprotease activity assays also fail to distinguish between various inactive molecules including partially denatured and fragmented material still retaining this protease activity. By co-coating microtiter plates with SNAP25 substrate and a monoclonal antibody specific for a conformational epitope of the toxin's Hc domain, it was possible to develop a highly sensitive (130 aM LoD), precise (1.4% GCV) new assay specific for the biologically active toxin molecule. Capture was performed in phosphate buffer with a fixed optimal concentration of chaotropic agent (e.g., 1.2 M urea) to differentially isolate functional toxin molecules. Addition of enzymatically favorable buffer containing zinc and DTT reduced the interchain disulfide bond releasing and activating the captured L-chain with subsequent specific cleavage of the SNAP25(1-206) substrate. A neoepitope antibody specific for the newly exposed Q(197) epitope was used to quantify the cleaved SNAP25(1-197). The assay's requirement for the intact toxin molecule was demonstrated with pre-reduced toxin (heavy and light chains), recombinant LHn fragments, and stressed samples containing partially or fully denatured material. This is the first known immunobiochemical assay that correlates with in vivo potency and provides a realistic alternative. PMID:22406430

  7. Comparison of a quantitative microtiter method, a quantitative automated method, and the plate-count method for determining microbial complement resistance.

    PubMed

    Lee, M D; Wooley, R E; Brown, J; Spears, K R; Nolan, L K; Shotts, E B

    1991-01-01

    A quantitative microtiter method for determining the degree of complement resistance or sensitivity of microorganisms is described. The microtiter method is compared with a quantitative automated system and the standard plate-count technique. Data were accumulated from 30 avian Escherichia coli isolates incubated at 35 C with either chicken plasma or heat-inactivated chicken plasma. Analysis of data generated by the automated system and plate-count techniques resulted in a classification of the microorganisms into three groups: those sensitive to the action of complement; those of intermediate sensitivity to the action of complement; and those resistant to the action of complement. Although the three methods studied did not agree absolutely, there were statistically significant correlations among them.

  8. A microtiter-plate screening method for biofilm disinfection and removal.

    PubMed

    Pitts, Betsey; Hamilton, Martin A; Zelver, Nicholas; Stewart, Philip S

    2003-08-01

    A quantitative spectrophotometric method was developed to measure the removal and killing efficacy of antibiofilm agents. Biofilms of Pseudomonas aeruginosa or Staphylococcus epidermidis were grown in 96-well plates, treated with an agent, then stained with either the biomass indicator crystal violet or the respiratory indicator 5-cyano-2,3-ditolyl tetrazolium chloride. This rapid screening method is sensitive enough to elucidate concentration-response relationships as well as differences between species responses to treatments. Using these assays, agents can be ranked by their ability to remove or kill biofilm. PMID:12782382

  9. Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates.

    PubMed

    Gehring, Andrew G; Brewster, Jeffrey D; He, Yiping; Irwin, Peter L; Paoli, George C; Simons, Tawana; Tu, Shu-I; Uknalis, Joseph

    2015-01-01

    Antibody microarray is a powerful analytical technique because of its inherent ability to simultaneously discriminate and measure numerous analytes, therefore making the technique conducive to both the multiplexed detection and identification of bacterial analytes (i.e., whole cells, as well as associated metabolites and/or toxins). We developed a sandwich fluorescent immunoassay combined with a high-throughput, multiwell plate microarray detection format. Inexpensive polystyrene plates were employed containing passively adsorbed, array-printed capture antibodies. During sample reaction, centrifugation was the only strategy found to significantly improve capture, and hence detection, of bacteria (pathogenic Escherichia coli O157:H7) to planar capture surfaces containing printed antibodies. Whereas several other sample incubation techniques (e.g., static vs. agitation) had minimal effect. Immobilized bacteria were labeled with a red-orange-fluorescent dye (Alexa Fluor 555) conjugated antibody to allow for quantitative detection of the captured bacteria with a laser scanner. Shiga toxin 1 (Stx1) could be simultaneously detected along with the cells, but none of the agitation techniques employed during incubation improved detection of the relatively small biomolecule. Under optimal conditions, the assay had demonstrated limits of detection of ~5.8 × 10⁵ cells/mL and 110 ng/mL for E. coli O157:H7 and Stx1, respectively, in a ~75 min total assay time. PMID:26690151

  10. Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates

    PubMed Central

    Gehring, Andrew G.; Brewster, Jeffrey D.; He, Yiping; Irwin, Peter L.; Paoli, George C.; Simons, Tawana; Tu, Shu-I; Uknalis, Joseph

    2015-01-01

    Antibody microarray is a powerful analytical technique because of its inherent ability to simultaneously discriminate and measure numerous analytes, therefore making the technique conducive to both the multiplexed detection and identification of bacterial analytes (i.e., whole cells, as well as associated metabolites and/or toxins). We developed a sandwich fluorescent immunoassay combined with a high-throughput, multiwell plate microarray detection format. Inexpensive polystyrene plates were employed containing passively adsorbed, array-printed capture antibodies. During sample reaction, centrifugation was the only strategy found to significantly improve capture, and hence detection, of bacteria (pathogenic Escherichia coli O157:H7) to planar capture surfaces containing printed antibodies. Whereas several other sample incubation techniques (e.g., static vs. agitation) had minimal effect. Immobilized bacteria were labeled with a red-orange-fluorescent dye (Alexa Fluor 555) conjugated antibody to allow for quantitative detection of the captured bacteria with a laser scanner. Shiga toxin 1 (Stx1) could be simultaneously detected along with the cells, but none of the agitation techniques employed during incubation improved detection of the relatively small biomolecule. Under optimal conditions, the assay had demonstrated limits of detection of ~5.8 × 105 cells/mL and 110 ng/mL for E. coli O157:H7 and Stx1, respectively, in a ~75 min total assay time. PMID:26690151

  11. Microtiter plate-based assay for inhibitors of penicillin-binding protein 2a from methicillin-resistant Staphylococcus aureus.

    PubMed

    Bobba, Sudheer; Ponnaluri, V K Chaithanya; Mukherji, Mridul; Gutheil, William G

    2011-06-01

    Penicillin-binding protein 2a (PBP2a), the molecular determinant for high-level β-lactam resistance in methicillin-resistant Staphylococcus aureus (MRSA), is intrinsically resistant to most β-lactam antibiotics. The development and characterization of new inhibitors targeting PBP2a would benefit from an effective and convenient assay for inhibitor binding. This study was directed toward the development of a fluorescently detected β-lactam binding assay for PBP2a from MRSA. Biotinylated ampicillin and biotinylated cephalexin were tested as tagging reagents for fluorescence detection by using a streptavidin-horseradish peroxidase conjugate. Both bound surprisingly well to PBP2a, with binding constants of 1.6 ± 0.4 μM and 13.6 ± 0.8 μM, respectively. Two forms of the assay were developed, a one-step direct competition form of the assay and a two-step indirect competition form of the assay, and both forms of the assay gave comparable results. This assay was then used to characterize PBP2a binding to ceftobiprole, which gave results consistent with previous studies of ceftobiprole-PBP2a binding. This assay was also demonstrated for screening for PBP2a inhibitors by screening a set of 13 randomly selected β-lactams for PBP2a inhibition at 750 μM. Meropenem was observed to give substantial inhibition in this screen, and a follow-up titration experiment determined its apparent K(i) to be 480 ± 70 μM. The availability of convenient and sensitive microtiter-plate based assays for the screening and characterization of PBP2a inhibitors is expected to facilitate the discovery and development of new PBP2a inhibitors for use in combating the serious public health problem posed by MRSA.

  12. Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells.

    PubMed

    Abd-Rabboh, Hisham S M; Meyerhoff, Mark E

    2007-05-15

    The determination of glucose in beverages is demonstrated using newly developed fluoride selective optical sensing polymeric film that contains aluminum (III) octaethylporphyrin (Al[OEP]) ionophore and the chromoionophore ETH7075 cast at the bottom of wells of a 96-well polypropylene microtiter plate. The method uses a dual enzymatic reaction involving glucose oxidase enzyme (GOD) and horseradish peroxidase (HRP), along with an organofluoro-substrate (4-fluorophenol) as the source of fluoride ions. The concentration of fluoride ions after enzymatic reaction is directly proportional to the glucose level in the sample. The method has a detection limit of 0.8 mmol L(-1), a linear range of 0.9- 40 mmol L(-1) and a sensitivity of 0.125 absorbance unit/decade of glucose concentration. Glucose levels in several beverage samples determined using the proposed method correlate well with a reference spectrophotometric enzyme method based on detection of hydrogen peroxide using bromopyrogallol red dye (BPR). The new method can also be used to determine H(2)O(2) concentrations in the 0.1 - 50 mmol L(-1) range using a single enzymatic reaction involving H(2)O(2) oxidation of 4-fluorophenol catalyzed by HRP. The methodology could potentially be used to detect a wide range of substrates for which selective oxidase enzymes exist (to generate H(2)O(2)), with the high throughput of simple microtiter plate detection scheme.

  13. Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells

    PubMed Central

    Abd-Rabboh, Hisham S. M.; Meyerhoff, Mark E.

    2007-01-01

    The determination of glucose in beverages is demonstrated using newly developed fluoride selective optical sensing polymeric film that contains aluminum (III) octaethylporphyrin (Al[OEP]) ionophore and the chromoionophore ETH7075 cast at the bottom of wells of a 96-well polypropylene microtiter plate. The method uses a dual enzymatic reaction involving glucose oxidase enzyme (GOD) and horseradish peroxidase (HRP), along with an organofluoro-substrate (4-fluorophenol) as the source of fluoride ions. The concentration of fluoride ions after enzymatic reaction is directly proportional to the glucose level in the sample. The method has a detection limit of 0.8 mmol L−1, a linear range of 0.9– 40 mmol L−1 and a sensitivity of 0.125 absorbance unit/decade of glucose concentration. Glucose levels in several beverage samples determined using the proposed method correlate well with a reference spectrophotometric enzyme method based on detection of hydrogen peroxide using bromopyrogallol red dye (BPR). The new method can also be used to determine H2O2 concentrations in the 0.1 - 50 mmol L−1 range using a single enzymatic reaction involving H2O2 oxidation of 4-fluorophenol catalyzed by HRP. The methodology could potentially be used to detect a wide range of substrates for which selective oxidase enzymes exist (to generate H2O2), with the high throughput of simple microtiter plate detection scheme. PMID:18480896

  14. Antimicrobial assay optimization and validation for HTS in 384-well format using a bioluminescent E. coli K-12 strain.

    PubMed

    Nybond, Susanna; Karp, Matti; Tammela, Päivi

    2013-07-16

    This report describes the optimization and validation of an antimicrobial assay based on the genetically modified bacterial strain Escherichia coli K-12 (pTetlux1). The use of this particular strain enables an inducible cell-based bioluminescent assay for high-throughput screening (HTS) of antimicrobial agents, which shows a pronounced detection of compounds targeting transcriptional and translational events in protein synthesis. The optimizations in 96-well format led to several improvements in assay conditions, such as reduction of the pre-incubation time before luminescence induction by half. The threshold for DMSO tolerability was concluded to be up to 1%. Assay protocol was further miniaturized into 384-well format and the liquid handling was automated using a robotic workstation. The use of compound pre-plating into 384-well plates as a part of the process was evaluated, and the total assay volume was further downscaled from 50 μl to 30 μl. With this approach, the amount of test compound needed per well was reduced to nanoliter volumes. Using the miniaturized protocol a pilot screen of 2000 known drugs and bioactives was performed. The assay performance was evaluated by calculating known assay quality parameters, the Z' factor having a mean value of 0.8 during the compound library screening indicated an excellent performance. Of the assay positives, 54 compounds showed high inhibitions (60-100%), of which the majority (89%) were known antibacterial agents. Of the actives showing >60% inhibition, 16 compounds were identified as known transcriptional and translational inhibitors. The screening results demonstrated that the miniaturized assay is well suited for identification of antimicrobial compounds in HT screening, and that the assay is specifically sensitive towards bacterial transcription and translation inhibitors.

  15. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors.

  16. An enzyme-amplified microtiter plate assay for ethanol: Its application to the detection of peanut ethanol and alcohol dehydrogenase

    SciTech Connect

    Chung, S.Y.; Vercellotti, J.R.; Sanders, T.H.

    1995-12-01

    A calorimetric microliter plate assay for ethanol amplified by aldehyde dehydrogenase (ALDH) was developed. In the assay ethanol from a sample took part in a chain-reaction catalyzed by alcohol dehydrogenase (ADH) and amplified by ALDH in the presence of NAD{sup +}, diaphorase, and p-ibdonitrotetrazolium-violet (INT-violet)(a precursor of red product). The resultant reaction gave a red color, the intensity of which was proportional to the amount of ethanol present. Using the technique, the content of activity from peanuts of differing maturity and curing stages were determined respectively. Data showed that immature peanuts had a higher level of ethanol and a lower ADH activity than mature peanuts, and that the level of ethanol and ADH activity decreased with the curing time. This indicates that peanut maturity and curing have an effect on ethanol. Also, this implies that other peanut volatiles could be affected in the same way as ethanol, a major volatile in peanuts.

  17. Design of a titering assay for lentiviral vectors utilizing direct extraction of DNA from transduced cells in microtiter plates

    PubMed Central

    Murphy, Michele E; Vin, Chintan D; Slough, Megan M; Gombotz, Wayne R; Kelley-Clarke, Brenna

    2016-01-01

    Using lentiviral vector products in clinical applications requires an accurate method for measuring transduction titer. For vectors lacking a marker gene, quantitative polymerase chain reaction is used to evaluate the number of vector DNA copies in transduced target cells, from which a transduction titer is calculated. Immune Design previously described an integration-deficient lentiviral vector pseudotyped with a modified Sindbis virus envelope for use in cancer immunotherapy (VP02, of the ZVex platform). Standard protocols for titering integration-competent lentiviral vectors employ commercial spin columns to purify vector DNA from transduced cells, but such columns are not optimized for isolation of extrachromosomal (nonintegrated) DNA. Here, we describe a 96-well transduction titer assay in which DNA extraction is performed in situ in the transduction plate, yielding quantitative recovery of extrachromosomal DNA. Vector titers measured by this method were higher than when commercial spin columns were used for DNA isolation. Evaluation of the method’s specificity, linear range, and precision demonstrate that it is suitable for use as a lot release assay to support clinical trials with VP02. Finally, the method is compatible with titering both integrating and nonintegrating lentiviral vectors, suggesting that it may be used to evaluate the transduction titer for any lentiviral vector. PMID:26942209

  18. A rapid microtiter plate method to measure carbon dioxide evolved from carbon substrate amendments so as to determine the physiological profiles of soil microbial communities by using whole soil.

    PubMed

    Campbell, Colin D; Chapman, Stephen J; Cameron, Clare M; Davidson, Mitchell S; Potts, Jacqueline M

    2003-06-01

    Sole-carbon-source tests (Biolog), designed to identify bacteria, have become very popular for metabolically fingerprinting soil microbial communities, despite disadvantages associated with the use of carbon source profiles that primarily select for fast-growing bacteria. In this paper we describe the use of an alternative method that combines the advantages of the Biolog community-level physiological profile (CLPP) method, in which microtiter-based detection plates are used, with the ability to measure carbon dioxide evolution from whole soil. This method facilitates measurement over short periods of time (4 to 6 h) and does not require the extraction and culturing of organisms. Deep-well microtiter plates are used as test wells into which soil is placed. The apparatus to fill the deep-well plates and interface it with a second removable detection plate is described. Two detection systems, a simple colorimetric reaction in absorbent alkali and scintillation counting with radioactive carbon sources, are described. The methods were compared to the Biolog-CLPP system by using soils under different vegetation types and soil treated with wastewater sludge. We aimed to test the hypothesis that using whole soil would have specific advantages over using extracts in that more immediate responses to substrates could be obtained that would reflect activity rather than growth. The whole-soil method was more rapid and gave earlier detection of C source use. Also, the metabolic fingerprints obtained could discriminate between sludge treatments.

  19. Comparison of lyophilized and frozen microtiter systems for routine MIC testing in the clinical laboratory.

    PubMed

    Polk, E A; Starr, A J; Friedman, H; Erb, L

    1982-08-01

    Frozen microtiter plates (Micro-Media Systems, Inc.) and lyophilized microtiter plates (Sensititre--Seward Laboratory/Gibco Diagnostics) were used to perform simultaneous MIC determinations. Specimens were obtained from blood, urine and other clinical isolates. The authors found that there was good correspondence of results with the frozen microtiter MIC plates and the lyophilized microtiter MIC plates. After careful evaluation, the authors conclude that the lyophilized product is as stable and as reproducible as the frozen product. The lyophilized product is more easily and conveniently stored, has a longer shelf life and is more flexible. PMID:7048941

  20. Kinetic Tetrazolium Microtiter Assay

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L.; Stowe, Raymond; Koenig, David

    1993-01-01

    Kinetic tetrazolium microtiter assay (KTMA) involves use of tetrazolium salts and Triton X-100 (or equivalent), nontoxic, in vitro color developer solubilizing colored metabolite formazan without injuring or killing metabolizing cells. Provides for continuous measurement of metabolism and makes possible to determine rate of action of antimicrobial agent in real time as well as determines effective inhibitory concentrations. Used to monitor growth after addition of stimulatory compounds. Provides for kinetic determination of efficacy of biocide, greatly increasing reliability and precision of results. Also used to determine relative effectiveness of antimicrobial agent as function of time. Capability of generating results on day of test extremely important in treatment of water and waste, disinfection of hospital rooms, and in pharmaceutical, agricultural, and food-processing industries. Assay also used in many aspects of cell biology.

  1. Development and Optimization of a Novel 384-Well Anti-Malarial Imaging Assay Validated for High-Throughput Screening

    PubMed Central

    Duffy, Sandra; Avery, Vicky M.

    2012-01-01

    With the increasing occurrence of drug resistance in the malaria parasite, Plasmodium falciparum, there is a great need for new and novel anti-malarial drugs. We have developed a 384-well, high-throughput imaging assay for the detection of new anti-malarial compounds, which was initially validated by screening a marine natural product library, and subsequently used to screen more than 3 million data points from a variety of compound sources. Founded on another fluorescence-based P. falciparum growth inhibition assay, the DNA-intercalating dye 4′,6-diamidino-2-phenylindole, was used to monitor changes in parasite number. Fluorescent images were acquired on the PerkinElmer Opera High Throughput confocal imaging system and analyzed with a spot detection algorithm using the Acapella data processing software. Further optimization of this assay sought to increase throughput, assay stability, and compatibility with our high-throughput screening equipment platforms. The assay typically yielded Z'-factor values of 0.5–0.6, with signal-to-noise ratios of 12. PMID:22232455

  2. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    PubMed Central

    Mohan, Anju; Saxena, Hari Mohan; Malhotra, Puneet

    2016-01-01

    Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT), microtiter plate agglutination test (MAT), indirect hemagglutination assay (IHA), and indirect enzyme-linked immunosorbent assay (iELISA) as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001). The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005). The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002). However, the difference in mean iELISA titers of infected cattle (1.3678±0.014) and healthy vaccinated cattle (1.367±0.014) was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. PMID:27536032

  3. Miniaturization of mitotic index cell-based assay using "wall-less" plate technology.

    PubMed

    Le Guezennec, Xavier; Phong, Mark; Nor, Liyana; Kim, Namyong

    2014-03-01

    The use of microscopic imaging for the accurate assessment of cells in mitosis is hampered by the round morphology of mitotic cells, which renders them poorly adherent and highly susceptible to loss during the washing stage of cell-based assays. Here, to circumvent these limitations, we make use of DropArray, a recent technology that allows high retention of weakly adherent cells and suspension cells. DropArray offers the competitive advantage of maintaining the classic high throughput format of microtiter plates while reducing classic microwell volume by up to 90% by using a drop format. Here, we present a mitotic index cell-based assay using the mitosis marker phospho histone H3 at serine 10 on a DropArray 384-well plate format. Dose-response curve analysis of the mitotic index assay with an antimitotic drug (docetaxel) on DropArray is presented that shows an effective dosage compared to previous established results similar to those obtained with conventional microtiter plates. The mitotic index assay with DropArray showed a Z-factor >0.6. Our results validate DropArray as a suitable platform for high throughput screening for compounds affecting mitosis or the cell cycle. PMID:24611478

  4. Influence of affinity on antibody determination in microtiter ELISA systems

    SciTech Connect

    Peterman, J.H.; Voss, E.W. Jr.; Butler, J.E.

    1986-03-01

    Theoretically, all immunoassays are affinity (Ka) dependent when the product of the antibody (Ab) Ka and the free epitope concentration is less than 10. Thus, the degree of dependence on Ka depends on the concentration of available antigen in the system. The authors examined the binding of /sup 125/I-anti-fluorescein (a-FLU) monoclonal antibodies of different affinities to FLU-gelatin adsorbed on Immunlon 2 microtiter plates. Data obtained were in general agreement with our theoretical predictions; the percent of /sup 125/I-a-FLU which bound correlated with Ka, as did the shape of the titration curves. Measurement of 5 a-FLU monoclonals by the ELISA showed that the determination of Ab concentrations depends on the FLU-gelatin concentration, epitope density, and on the relationship between the Kas of test samples and the reference standard Ab preparation. Thus the ELISA is Ka dependent and should not be used routinely to estimate the absolute amount to Ab in unknown samples. However, the Ka dependency of the ELISA might provide a convenient assay for the estimation of the relative functional Ka (rfKa) of antibody preparations.

  5. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  6. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  7. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  8. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  9. 21 CFR 866.2500 - Microtiter diluting and dispensing device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microtiter diluting and dispensing device. 866.2500 Section 866.2500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices §...

  10. Application of a microtiter cell-culture method to characterization of avian adenoviruses.

    PubMed

    Grimes, T M; King, D J; Kleven, S H

    1976-01-01

    A microtiter cell-culture method was developed and used to titrate virus isolates for characterization. Virus dilutions and chicken kidney cell suspensions were dispensed into the wells of disposable microculture plates, with infectivity endpoints being determined microscopically on the fifth or sixth day, or by reading crystal-violet-stained monolayers on day 6. With this method, 37 candidate avian adenoviruses isolated from diagnostic accessions were characterized as avian adenoviruses (AAV). The criteria used for characterization were production of round-cell cytopathic effect, resistance to chloroform treatment, inhibition by 5-bromodeoxyuridine, and the presence of an antigen showing identity with a known AAV by precipitation in agar gel. Statistical anlaysis of eight replicate titrations of three AAV indicated that the titration method was highly reproducible. Use of the microculture method for titrations gave substantial savings in indicator cells, media, incubator space, culture dishes, and time.

  11. Comparison of microtiter procedures with the plaque technique for assay of vesicular stomatitis virus.

    PubMed

    Rosenthal, L J; Shechmeister, I L

    1971-03-01

    This paper describes a microprocedure for the tissue culture assay of vesicular stomatitis virus (VSV) and compares the sensitivity of the method with the conventional plaque assay of viral concentration. Microtiter and plaque assay methods were used in titrations, neutralization tests, and thermoinactivation studies with this virus in chick embryo fibroblasts (CEF) and L, HeLa, and PK cell lines. Titration experiments with VSV by the microtiter procedure on preformed monolayers were significantly more sensitive than the plaque assay (P = 0.05). The results of the neutralization tests and thermoinactivation studies also showed greater ability to detect residual virus by the microtiter procedure (P = 0.10). In addition, the microtiter procedure was simpler, less costly, and more rapid than the plaque assay.

  12. Folate content in fresh-cut vegetable packed products by 96-well microtiter plate microbiological assay.

    PubMed

    Fajardo, Violeta; Alonso-Aperte, Elena; Varela-Moreiras, Gregorio

    2015-02-15

    Ready-to-eat foods have nowadays become a significant portion of the diet. Accordingly, nutritional composition of these food categories should be well-known, in particular its folate content. However, there is a broad lack of folate data in food composition tables and databases. A total of 21 fresh-cut vegetable and fruit packed products were analysed for total folate (TF) content using a validated method that relies on the folate-dependent growth of chloramphenicol-resistant Lactobacillus casei subspecies rhamnosus (NCIMB 10463). Mean TF content ranged from 10.0 to 140.9μg/100g for the different matrices on a fresh weight basis. Higher TF quantity, 140.9-70.1μg/100g, was found in spinach, rocket, watercress, chard and broccoli. Significant differences were observed between available data for fresh vegetables and fruits from food composition tables or databases and the analysed results for fresh-cut packed products. Supplied data support the potential of folate-rich fresh-cut ready-to-eat vegetables to increase folate intake significantly.

  13. Community-level physiological profiling performed with an oxygen-sensitive fluorophore in a microtiter plate

    NASA Technical Reports Server (NTRS)

    Garland, Jay L.; Roberts, Michael S.; Levine, Lanfang H.; Mills, Aaron L.

    2003-01-01

    Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.

  14. A rapid method for detecting specific amplified PCR fragments in microtiter plates.

    PubMed Central

    Ortiz, A; Ritter, E

    1996-01-01

    A simple method is presented to circumvent laborious and time consuming electrophoretic separations of specific PCR amplification products. Specific target DNA is amplified using nucleotides labelled with DIG-dUTP or biotin-dCTP. The labelled PCR products are separated from unincorporated nucleotides or oligonucleotides by using a positively charged DEAE cellulose matrix. Amplification products are visualized directly in the matrix using immunoenzymatic methods or streptavidin-conjugated enzymes. The detection process can be carried out within 2 h, allows the processing of large sample sizes and can potentially be automated. PMID:8774915

  15. Optimizing a Candida Biofilm Microtiter Plate Model for Measurement of Antifungal Susceptibility by Tetrazolium Salt Assay▿

    PubMed Central

    Nett, Jeniel E.; Cain, Michael T.; Crawford, Kyler; Andes, David R.

    2011-01-01

    Candida spp. infect medical devices, such as venous and urinary catheters, by adhering to the surface and forming a community of drug-resistant cells surrounded by a matrix. The ability to measure drug activity during this biofilm mode of growth is of interest for the investigation of resistance mechanisms and novel antifungal therapies. The tetrazolium salt (XTT) reduction assay is the test most commonly used to estimate viable biofilm growth and to examine the impact of biofilm therapies. The primary goal of the current experiments was to identify assay variables that affect the XTT assay result in order to improve assay reproducibility, sensitivity, and throughput for the study of antifungal activity. The species used in the current studies included Candida albicans, C. parapsilosis, and C. glabrata. The assay variables that were studied included the impact of culture conditions, the duration of biofilm growth, the timing and frequency of drug administration, the XTT source and concentration, and the duration of XTT incubation. The conditions that impacted the assay readout and altered assay sensitivity included the duration of biofilm growth, the frequency of drug dosing, and the duration of XTT incubation. Several factors were found to reduce time and assay expense, including the elimination of washing steps, the shortening of incubation times, and the use of lower XTT concentrations. A description of assay pitfalls and troubleshooting is included. Recognition of these technical variables should allow investigators to better design reproducible biofilm therapeutic studies. PMID:21227984

  16. Labeling cells in microtiter plates for determination of [3H]thymidine uptake.

    PubMed

    Shevach, E M

    2001-05-01

    A number of protocols in Current Protocols in Immunology use as their end-point the determination of cell proliferation by determining the incorporation of [(3)H]thymidine into cellular DNA. This appendix presents a protocol in which the radioactive label is added during the last 4 to 24 hr of the culture. A semiautomated cell harvesting apparatus is then used to lyse the cells with water and precipitate the labeled DNA on glass fiber filters. The filter pads are then dried and counted by standard liquid scintillation counting techniques in a scintillation counter. PMID:18432656

  17. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    NASA Astrophysics Data System (ADS)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  18. Quantitation of dye binding by cell monolayers in a microtiter system.

    PubMed

    Barer, M R; Lyon, H; Drasar, B S

    1986-01-01

    A semi-automated system has been developed for the quantitation of dye binding to cultured eukaryotic cells. It is based on staining precisely controlled numbers of cells seeded into microtiter trays. Cell-bound stain is then released using an appropriate solvent and quantitated in situ by measuring absorbance in a single beam ELISA reader with an interactive microcomputer link. In order to illustrate potential applications of this approach, the time course of dye-monolayer association and influence of cell number and stain concentration on staining has been examined for four dyes, Crystal Violet, Naphthol Yellow S, Ethyl Green and Pyronin Y. In addition, the effect of sequential and simultaneous staining was examined for Ethyl Green and Pyronin Y. The results provide evidence for the overall reliability of this approach as well as revealing several interesting features in the individual procedures examined. The combination of microtiter technology and computer link make the system particularly well suited to the efficient investigation of the permutations involved in optimizing conditions for a given staining procedure, as well as analysis of the thermodynamics of dye substrate interaction. Overall, the approach is viewed as an intermediate between artificial gel systems and microdensitometry.

  19. Epstein-Barr virus viral capsid antigen titer by immunofluorescence with microplates: new semiautomated method based on the microtiter system.

    PubMed

    Lamy, M E; Favart, A M; Burtonboy, G; Arana, A

    1977-07-01

    A semiautomated method of an indirect immunofluorescence technique for the titration of antibodies directed against viral capsid antigens of Epstein-Barr virus has been developed with Microtiter system units. By this method, a technician is able to titrate some hundred samples daily. The technique is safe, easy, and reproducible. The various procedures are described, and the sensitivity of the test is discussed.

  20. Acute effects of ethanol or d-amphetamine on the locomotor activity of larval zebrafish in a microtiter plate format.

    EPA Science Inventory

    As part of an effort to develop a rapid in vivo screen for EPA’s prioritization of toxic chemicals, we have begun to characterize the locomotor activity of zebrafish (Danio rerio) larvae. We are assessing the acute effects of prototypic drugs that are known to act on the central ...

  1. A microtiter test for detecting and titrating noncytopathogenic bovine viral diarrhea virus.

    PubMed

    Maisonnave, J; Rossi, C R

    1982-01-01

    Bovine cells free of noncytopathogenic bovine viral diarrhea virus (NC-BVDV) treated with polyriboinosinic acid : polyribocytidylic acid (poly I:C) were protected against challenge with vesicular stomatitis virus (VSV), whereas NC-BVDV-infected cells treated with poly I:C were not protected against VSV. An assay based on the ability of NC-BVDV to inhibit poly I:C protection of cells against VSV was developed and is herein referred to as PINBA (poly I:C for NC-BVDV assay). Noncytopathogenic BVDV was titrated as cytopathogenic strains except that several days after infection with NC-BVDV, the cultures were treated with poly I:C and VSV. Titration endpoints were reached 24 hours later. PINBA was standardized for amount of VSV, time of addition of poly I:C, and time NC-BVDV had to be present to obtain stable titration endpoints. PINBA also was useful for titrating virus neutralizing antibodies. Compared with the fluorescent antibody test, PINBA was less subjective for detection of NC-BVDV. Compared with the interference test in which NC-BVDV infected cultures are challenged with a cytopathogenic strain of BVDV, PINBA was more reliable. The technique described herein is a simple and practical microtiter method for titrating NC-BVDV and virus neutralizing antibodies and for the presumptive detection of NC-BVDV.

  2. A Quantitative Microtiter Assay for Sialylated Glycoform Analyses Using Lectin Complexes.

    PubMed

    Srinivasan, Karunya; Roy, Sucharita; Washburn, Nathaniel; Sipsey, Sandra F; Meccariello, Robin; Meador, James W; Ling, Leona E; Manning, Anthony M; Kaundinya, Ganesh V

    2015-07-01

    Fidelity of glycan structures is a key requirement for biotherapeutics, with carbohydrates playing an important role for therapeutic efficacy. Comprehensive glycan profiling techniques such as liquid chromatography (LC) and mass spectrometry (MS), while providing detailed description of glycan structures, require glycan cleavage, labeling, and paradigms to deconvolute the considerable data sets they generate. On the other hand, lectins as probes on microarrays have recently been used in orthogonal approaches for in situ glycoprofiling but require analyte labeling to take advantage of the capabilities of automated microarray readers and data analysis they afford. Herein, we describe a lectin-based microtiter assay (lectin-enzyme-linked immunosorbent assay [ELISA]) to quantify terminal glycan moieties, applicable to in vitro and in-cell glycan-engineered Fc proteins as well as intact IgGs from intravenous immunoglobulin (IVIG), a blood product containing pooled polyvalent IgG antibodies extracted from plasma from healthy human donors. We corroborate our findings with industry-standard LC-MS profiling. This "customizable" ELISA juxtaposes readouts from multiple lectins, focusing on a subset of glycoforms, and provides the ability to discern single- versus dual-arm glycosylation while defining levels of epitopes at sensitivities comparable to MS. Extendable to other biologics, this ELISA can be used stand-alone or complementary to MS for quantitative glycan analysis. PMID:25851037

  3. A Quantitative Microtiter Assay for Sialylated Glycoform Analyses Using Lectin Complexes

    PubMed Central

    Srinivasan, Karunya; Washburn, Nathaniel; Sipsey, Sandra F.; Meccariello, Robin; Meador, James W.; Ling, Leona E.; Manning, Anthony M.; Kaundinya, Ganesh V.

    2015-01-01

    Fidelity of glycan structures is a key requirement for biotherapeutics, with carbohydrates playing an important role for therapeutic efficacy. Comprehensive glycan profiling techniques such as liquid chromatography (LC) and mass spectrometry (MS), while providing detailed description of glycan structures, require glycan cleavage, labeling, and paradigms to deconvolute the considerable data sets they generate. On the other hand, lectins as probes on microarrays have recently been used in orthogonal approaches for in situ glycoprofiling but require analyte labeling to take advantage of the capabilities of automated microarray readers and data analysis they afford. Herein, we describe a lectin-based microtiter assay (lectin–enzyme-linked immunosorbent assay [ELISA]) to quantify terminal glycan moieties, applicable to in vitro and in-cell glycan-engineered Fc proteins as well as intact IgGs from intravenous immunoglobulin (IVIG), a blood product containing pooled polyvalent IgG antibodies extracted from plasma from healthy human donors. We corroborate our findings with industry-standard LC-MS profiling. This “customizable” ELISA juxtaposes readouts from multiple lectins, focusing on a subset of glycoforms, and provides the ability to discern single- versus dual-arm glycosylation while defining levels of epitopes at sensitivities comparable to MS. Extendable to other biologics, this ELISA can be used stand-alone or complementary to MS for quantitative glycan analysis. PMID:25851037

  4. Detection of Salmonella by using the colorimetric DNA/rRNA sandwich hybridization in microtiter wells.

    PubMed

    Namimatsu, T; Tsuna, M; Imai, Y; Futo, S; Mitsuse, S; Sakano, T; Sato, S

    2000-06-01

    A rapid and readily available DNA probe kit was developed for the detection of Salmonella spp. This kit utilized the colorimetric DNA/rRNA sandwich hybridization method in microtiter wells. Within 3 hr Salmonella spp. in selective enrichment broth cultures were detected by the DNA probe kit. The kit effectively identified all of 187 strains of Salmonella tested and yielded no false-positive reactions in the examination of 674 pure cultures of non-salmonellae. The DNA probe kit could detect 10(5) cfu/ml in pure culture. A total of 379 naturally contaminated samples (raw chicken meat, liquid egg, animal feeds, poultry feces and frozen foods) were tested, both by the standard culture method and the DNA probe kit. The 169 of these samples were culture positive and 210 were culture negative. The sensitivity of the DNA probe kit was 98.2% (166/169) and the specificity was 99.5% (209/210). These results show that the DNA probe kit is a useful tool to examine a large number of various samples for contamination by Salmonella spp. in food and livestock industry. PMID:10907688

  5. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  6. Fluorescence lifetime plate reader: resolution and precision meet high-throughput.

    PubMed

    Petersen, Karl J; Peterson, Kurt C; Muretta, Joseph M; Higgins, Sutton E; Gillispie, Gregory D; Thomas, David D

    2014-11-01

    We describe a nanosecond time-resolved fluorescence spectrometer that acquires fluorescence decay waveforms from each well of a 384-well microplate in 3 min with signal-to-noise exceeding 400 using direct waveform recording. The instrument combines high-energy pulsed laser sources (5-10 kHz repetition rate) with a photomultiplier and high-speed digitizer (1 GHz) to record a fluorescence decay waveform after each pulse. Waveforms acquired from rhodamine or 5-((2-aminoethyl)amino) naphthalene-1-sulfonic acid dyes in a 384-well plate gave lifetime measurements 5- to 25-fold more precise than the simultaneous intensity measurements. Lifetimes as short as 0.04 ns were acquired by interleaving with an effective sample rate of 5 GHz. Lifetime measurements resolved mixtures of single-exponential dyes with better than 1% accuracy. The fluorescence lifetime plate reader enables multiple-well fluorescence lifetime measurements with an acquisition time of 0.5 s per well, suitable for high-throughput fluorescence lifetime screening applications.

  7. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  8. High-throughput measurements of biochemical responses using the plate::vision multimode 96 minilens array reader.

    PubMed

    Huang, Kuo-Sen; Mark, David; Gandenberger, Frank Ulrich

    2006-01-01

    The plate::vision is a high-throughput multimode reader capable of reading absorbance, fluorescence, fluorescence polarization, time-resolved fluorescence, and luminescence. Its performance has been shown to be quite comparable with other readers. When the reader is integrated into the plate::explorer, an ultrahigh-throughput screening system with event-driven software and parallel plate-handling devices, it becomes possible to run complicated assays with kinetic readouts in high-density microtiter plate formats for high-throughput screening. For the past 5 years, we have used the plate::vision and the plate::explorer to run screens and have generated more than 30 million data points. Their throughput, performance, and robustness have speeded up our drug discovery process greatly.

  9. Resonant waveguide grating imager for live cell sensing

    NASA Astrophysics Data System (ADS)

    Ferrie, Ann M.; Wu, Qi; Fang, Ye

    2010-11-01

    We report on a resonant waveguide grating imager for high throughput screening using live cells. This imager can generate a snapshot image of all biosensors in a 384-well microtiter plate with a time resolution of ˜3 s and a spatial resolution of 80 μm. This imager is well tolerant to variability in plate configurations and cell confluency. The resonant wavelength and its shifts induced by cell responses at each pixel correlate well with cell confluency. Data filtration protocol can be used to improve assay quality for partially confluent cells.

  10. Biofilm Localization in the Vertical Wall of Shaking 96-Well Plates

    PubMed Central

    Gomes, Luciana C.; Moreira, Joana M. R.; Simões, Manuel; Melo, Luís F.; Mergulhão, Filipe J.

    2014-01-01

    Microtiter plates with 96 wells are being increasingly used for biofilm studies due to their high throughput, low cost, easy handling, and easy application of several analytical methods to evaluate different biofilm parameters. These methods provide bulk information about the biofilm formed in each well but lack in detail, namely, regarding the spatial location of the biofilms. This location can be obtained by microscopy observation using optical and electron microscopes, but these techniques have lower throughput and higher cost and are subjected to equipment availability. This work describes a differential crystal violet (CV) staining method that enabled the determination of the spatial location of Escherichia coli biofilms formed in the vertical wall of shaking 96-well plates. It was shown that the biofilms were unevenly distributed on the wall with denser cell accumulation near the air-liquid interface. The results were corroborated by scanning electron microscopy and a correlation was found between biofilm accumulation and the wall shear strain rates determined by computational fluid dynamics. The developed method is quicker and less expensive and has a higher throughput than the existing methods available for spatial location of biofilms in microtiter plates. PMID:24834360

  11. Kinetic tetrazolium microtiter assay

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L. (Inventor); Stowe, Raymond P. (Inventor); Koeing, David W. (Inventor)

    1992-01-01

    A method for conducting an in vitro cell assay using a tetrazolium indicator is disclosed. The indicator includes a nonionic detergent which solubilizes a tetrazolium reduction product in vitro and has low toxicity for the cells. The incubation of test cells in the presence of zolium bromide and octoxynol (TRITON X-100) permits kinetics of the cell metabolism to be determined.

  12. Epstein-Barr virus early antigen titer by immunofluorescence in microplates. A new semi-automated method based on microtiter system.

    PubMed

    Favart, A M; Lamy, M E; Allemeersch, D; Burtonboy, G; Vanoverschelde, J

    1978-11-17

    For the titration of antibodies directed against Epstein-Barr Virus early antigen (EBV-EA) we describe a method in microplates with the Microtiter System (Cooke Engineering Co., Alexandria, Va). Using this technique, which allows rapid epidemiological investigations, we have titered anti-EBV-EA antibodies in different groups of patients and controls, and particularly in group which had recent contact with infectious mononucleosis. In this group the percentage of individuals having antibodies directed against the EBV-EA antigen was significantly higher than in the group of controls.

  13. Microfluidic titer plate for stratified 3D cell culture.

    PubMed

    Trietsch, Sebastiaan J; Israëls, Guido D; Joore, Jos; Hankemeier, Thomas; Vulto, Paul

    2013-09-21

    Human tissues and organs are inherently heterogeneous. Their functionality is determined by the interplay between different cell types, their secondary architecture, vascular system and gradients of signaling molecules and metabolites. Here we propose a stratified 3D cell culture platform, in which adjacent lanes of gels and liquids are patterned by phaseguides to capture this tissue heterogeneity. We demonstrate 3D cell culture of HepG2 hepatocytes under continuous perfusion, a rifampicin toxicity assay and co-culture with fibroblasts. 4T1 breast cancer cells are used to demonstrate invasion and aggregation models. The platform is incorporated in a microtiter plate format that renders it fully compatible with automation and high-content screening equipment. The extended functionality, ease of handling and full compatibility to standard equipment is an important step towards adoption of Organ-on-a-Chip technology for screening in an industrial setting.

  14. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  15. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  16. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  17. ASSEMBLY OF PARALLEL PLATES

    DOEpatents

    Groh, E.F.; Lennox, D.H.

    1963-04-23

    This invention is concerned with a rigid assembly of parallel plates in which keyways are stamped out along the edges of the plates and a self-retaining key is inserted into aligned keyways. Spacers having similar keyways are included between adjacent plates. The entire assembly is locked into a rigid structure by fastening only the outermost plates to the ends of the keys. (AEC)

  18. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  19. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  20. Plating Tank Control Software

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  1. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  2. Angular shear plate

    SciTech Connect

    Ruda, Mitchell C.; Greynolds, Alan W.; Stuhlinger, Tilman W.

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  3. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  4. Geologically current plate motions

    NASA Astrophysics Data System (ADS)

    DeMets, Charles; Gordon, Richard G.; Argus, Donald F.

    2010-04-01

    We describe best-fitting angular velocities and MORVEL, a new closure-enforced set of angular velocities for the geologically current motions of 25 tectonic plates that collectively occupy 97 per cent of Earth's surface. Seafloor spreading rates and fault azimuths are used to determine the motions of 19 plates bordered by mid-ocean ridges, including all the major plates. Six smaller plates with little or no connection to the mid-ocean ridges are linked to MORVEL with GPS station velocities and azimuthal data. By design, almost no kinematic information is exchanged between the geologically determined and geodetically constrained subsets of the global circuit-MORVEL thus averages motion over geological intervals for all the major plates. Plate geometry changes relative to NUVEL-1A include the incorporation of Nubia, Lwandle and Somalia plates for the former Africa plate, Capricorn, Australia and Macquarie plates for the former Australia plate, and Sur and South America plates for the former South America plate. MORVEL also includes Amur, Philippine Sea, Sundaland and Yangtze plates, making it more useful than NUVEL-1A for studies of deformation in Asia and the western Pacific. Seafloor spreading rates are estimated over the past 0.78 Myr for intermediate and fast spreading centres and since 3.16 Ma for slow and ultraslow spreading centres. Rates are adjusted downward by 0.6-2.6mmyr-1 to compensate for the several kilometre width of magnetic reversal zones. Nearly all the NUVEL-1A angular velocities differ significantly from the MORVEL angular velocities. The many new data, revised plate geometries, and correction for outward displacement thus significantly modify our knowledge of geologically current plate motions. MORVEL indicates significantly slower 0.78-Myr-average motion across the Nazca-Antarctic and Nazca-Pacific boundaries than does NUVEL-1A, consistent with a progressive slowdown in the eastward component of Nazca plate motion since 3.16 Ma. It also

  5. Hypervelocity plate acceleration

    SciTech Connect

    Marsh, S.P.; Tan, T.H.

    1991-01-01

    Shock tubes have been used to accelerate 1.5-mm-thick stainless steel plates to high velocity while retaining their integrity. The fast shock tubes are 5.1-cm-diameter, 15.2-cm-long cylinders of PBX-9501 explosive containing a 1.1-cm-diameter cylindrical core of low-density polystyrene foam. The plates have been placed directly in contact with one face of the explosive system. Plane-wave detonation was initiated on the opposite face. A Mach disk was formed in the imploding styrofoam core, which provided the impulse required to accelerate the metal plate to high velocity. Parametric studies were made on this system to find the effect of varying plate metal, plate thickness, foam properties, and addition of a barrel. A maximum plate velocity of 9.0 km/s has been observed. 6 refs., 17 figs.

  6. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  7. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  8. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  9. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    PubMed

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories.

  10. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  11. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  12. Turbine vane plate assembly

    SciTech Connect

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  13. Plating To Reinforce Welded Joints

    NASA Technical Reports Server (NTRS)

    Otousa, J. E.

    1982-01-01

    Electrodeposition used to strengthen welded joints gouged, nicked, or suffered other mechanical damage. Plating cell, typically of acrylic plastic such as poly (Methylmetacrylate), is assembled around part to be plated. Areas not to be plated are masked with plater's tape. Weld area is plated in standard nickel-plating process.

  14. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  15. Lohse's historic plate archive

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  16. Computational valve plate design

    NASA Astrophysics Data System (ADS)

    Kalbfleisch, Paul

    Axial piston machines are widely used in many industries for their designs compactness, flexibility in power transfer, variable flow rate, and high efficiencies as compared to their manufacturing costs. One important component of all axial piston machines that is a very influential on the performance of the unit is the valve plate. The aim of this research is to develop a design methodology that is general enough to design all types of valve plates and the simple enough not to require advanced technical knowledge from the user. A new style of valve plate designs has been developed that comprehensively considers all previous design techniques and does not require significant changes to the manufacturing processes of valve plates. The design methodology utilizes a previously developed accurate computer model of the physical phenomenon. This allows the precise optimization of the valve plate design through the use of simulations rather than expensive trial and error processes. The design of the valve plate is clarified into the form of an optimization problem. This formulation into an optimization problem has motivated the selection of an optimization algorithm that satisfies the requirements of the design. The proposed design methodology was successfully tested in a case study in the shown to be very successful in improving required performance of the valve plate design.

  17. Plate removal following orthognathic surgery.

    PubMed

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature.

  18. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  19. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors. PMID:25618046

  20. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors.

  1. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  2. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  3. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  4. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  5. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  6. The Potsdam Plate Archive

    NASA Astrophysics Data System (ADS)

    Boehm, P.; Steinmetz, M.; Tsvetkov, M.; Tsvetkova, K.

    2006-08-01

    The Virtual Observatory (VO) project will provide a global network platform to support modern astronomical research with fast and easy access to distributed archives via a unified interface and data model. Our aim is to include the historical photographic plates of the Potsdam observatory into this database in the framework of GAVO, the German contribution to VO. This work is part of the DFG project 436 BUL. The Postdam collection of wide-field plates consists of 11 archives, obtained from 1879 to 1970 (see Catalogue of Wide-Field Plate Archives, version 5.0, March 2005, http://www.skyarchive.org/catalogue.html), with a total amount of about 10000 plates and films stored not only in Potsdam but also in Leiden and Sonneberg. Apart from the long timeline provided for the observed objects, the archives reflect the history and development of the Potsdam observatory and of astronomical photography as well. The first astronomical photographs represent a scientific treasure. They offer the possibility to follow the photometric behavior of astronomical objects for about 120 years. This information is unique, because no more reproducible. Our aim is to digitize the old plates as long as their physical status does still allow it, and continue their systematic incorporation into the already existing Wide-Field Plate Database. These data can be used to search for any kind of long-term brightness variations like new flare stars or rapidly varying stars (Froehlich et al., 2002, A&A 391).

  7. A rapid method to verify single-cell deposition setup for cell sorters.

    PubMed

    Rodrigues, Olivia Roos; Monard, Simon

    2016-06-01

    Studying single cells reveals biology that cannot be explored using bulk techniques. Cell sorters provide the opportunity of separating single cells either for cell culture or for downstream molecular applications such as qPCR to study specific gene expression and single cell mRNA sequencing. Some of these molecular studies can be expensive so the investigator will often want reassurance that the cell sorter can reliably deposit a single droplet into each well of a 96-well or 384-well plate. Such plates may contain very small volumes of fluid as reducing the volume of fluid used can reduce the cost of the assay. To miss some of the wells could leave the data set incomplete requiring costly repetition. To verify this by microscopy is at best very time consuming and at worst impossible. Here, an inexpensive colorimetric method is described for verifying whether a well, in either a 96- or 384-well plate, did receive a single sorted droplet from a cell sorter into the fluid at the bottom of the well. The droplet consists of particles suspended in an enzymatic solution, horseradish peroxidase, which is deposited into microtiter plate wells containing a substrate, 3,3',5,5'-tetramethylbenzidine. This method requires no special equipment or expertise and is rapid enough to be performed directly prior to the single-cell sorting experiment. © 2016 International Society for Advancement of Cytometry. PMID:27144818

  8. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  9. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  10. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  11. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  12. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  13. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  14. Intermittent Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Silver, P. G.; Behn, M. D.

    2006-12-01

    Intermittent Plate Tectonics A basic premise of Earth Science is that plate tectonics has been continuously operating since it began early in Earth's history. Yet, plate-tectonic theory itself, specifically the collisional phase of the Wilson Cycle, constitutes a process that is capable of stopping all plate motion. The plausibility of a plate-tectonic hiatus is most easily illustrated by considering the expected future of the present-day plate-tectonic configuration. Since the opening of the Atlantic at ~200 ma, the area of the Atlantic basin has been growing at the expense of the Pacific. If this trend continues, relative plate motion models predict that in ~350 my, the Pacific Ocean basin will effectively close leading to widespread continent-continent collisions. Since a continent-continent collision represents the termination of subduction locally, the accumulated effect of all collisions is to stop subduction globally. In this scenario, ridges would then stop spreading and young oceanic lithosphere would cool, reaching a steady-state thickness of 100 km in about 80 my, based on the properties of oceanic lithosphere today. This would constitute the stoppage of plate tectonics. The presumption that plate tectonics never stops in the face of continental collisions is equivalent to requiring that subduction flux is approximately constant through time, such that subduction initiation roughly balances subduction termination. Such a balance then raises several questions about the subduction initiation process. When and how does subduction initiate? Is there a detectible relationship between subduction cessation and subduction initiation? We can gain some guidance into these questions by examining the plate motion history over the last 200 my. Subduction initiation has occurred over the last 80 my in three intra- oceanic subduction zones: Aleutians, Marianas-Izu-Bonin and Tonga-Kermadec in the Pacific basin. In these cases, however, subduction initiation would not

  15. Comparison of GD2 Binding Capture ELISA Assays for Anti-GD2-Antibodies Using GD2-Coated Plates and a GD2-Expressing Cell-Based ELISA

    PubMed Central

    Soman, Gopalan; Yang, Xiaoyi; Jiang, Hengguang; Giardina, Steve; Mitra, Gautam

    2011-01-01

    Two assay methods for quantification of the disialoganglioside (GD2)-specific binding activities of anti-GD2 monoclonal antibodies and antibody immunofusion proteins, such as ch14.18 and hu14.18-IL2, were developed. The methods differed in the use of either microtiter plates coated with purified GD2 or plates seeded with GD2-expressing cell lines to bind the anti-GD2 molecules. The bound antibodies were subsequently detected using the reactivity of the antibodies to an HRP-labeled anti-IgG Fc or antibodies recognizing the conjugate IL-2 part of the Hu 14.18IL-2 fusion protein. The bound HRP was detected using reagents such as orthophenylene diamine, 2, 2’-azinobis [3-ethylbenzothiazoline-6-sulfonic acid] or tetramethylbenzidine. The capture ELISA using GD2-coated plates was developed earlier in assay development and used to demonstrate assay specificity and to compare lot-to-lot consistency and stability of ch14.18, and Hu14.18 IL-2 in clinical development. During this study, we found a number of issues related to plate-to-plate variability, GD2 lot variability, and variations due to GD2 storage stability, etc., that frequently lead to assay failure in plates coated with purified GD2. The cell-based ELISA (CbELISA) using the GD2 expressing melanoma cell line, M21/P6, was developed as an alternative to the GD2-coated plate ELISA. The results on the comparability of the capture ELISA on GD2-coated plates and the cell-based assay show that both assays give comparable results. However, the cell-based assay is more consistent and reproducible. Subsequently, the anti-GD2 capture ELISA using the GD2-coated plate was replaced with the CbELISA for product lot release testing and stability assessment. PMID:21893062

  16. Nuclear reactor alignment plate configuration

    DOEpatents

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  17. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  18. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  19. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  20. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  1. MyPlate Food Guide

    MedlinePlus

    ... follow throughout your life. 2. Fruits Like veggies, fruits contain vitamins, minerals, and fiber. The red section of MyPlate is slightly smaller than the green, but together fruits and veggies should fill half your plate. Whole ...

  2. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for example, frostbite)  Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  3. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are: Child abuse Injury from extreme cold (for example, frostbite) Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  4. North American plate dynamics

    NASA Technical Reports Server (NTRS)

    Richardson, Randall M.; Reding, Lynn M.

    1991-01-01

    Deformation within the North American plate in response to various tectonic processes is modeled using an elastic finite element analysis. The tectonic processes considered in the modeling include ridge forces associated with the normal thermal evolution of oceanic lithosphere, shear and normal stresses transmitted across transforms, normal stresses transmitted across convergent boundaries, stresses due to horizontal density contrasts within the continent, and shear tractions applied along the base of the plate. Model stresses are calculated with respect to a lithostatic reference stress state. Shear stresses transmitted across transform boundaries along the San Andreas and Caribbean are small, of the order of 5-10 MPa. Also, compressive stresses of the order of 5-10 MPa transmitted across the major transforms improve the fit to the data. Compressive stresses across convergent margins along the Aleutians and the Middle America trench are important.

  5. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  6. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  7. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  8. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  9. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  10. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  11. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  12. Plates with Incompatible Prestrain

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Kaushik; Lewicka, Marta; Schäffner, Mathias

    2016-07-01

    We study effective elastic behavior of the incompatibly prestrained thin plates, where the prestrain is independent of thickness and uniform through the plate's thickness h. We model such plates as three-dimensional elastic bodies with a prescribed pointwise stress-free state characterized by a Riemannian metric G, and seek the limiting behavior as {h to 0}. We first establish that when the energy per volume scales as the second power of h, the resulting {Γ} -limit is a Kirchhoff-type bending theory. We then show the somewhat surprising result that there exist non-immersible metrics G for whom the infimum energy (per volume) scales smaller than h 2. This implies that the minimizing sequence of deformations carries nontrivial residual three-dimensional energy but it has zero bending energy as seen from the limit Kirchhoff theory perspective. Another implication is that other asymptotic scenarios are valid in appropriate smaller scaling regimes of energy. We characterize the metrics G with the above property, showing that the zero bending energy in the Kirchhoff limit occurs if and only if the Riemann curvatures R 1213, R 1223 and R 1212 of G vanish identically. We illustrate our findings with examples; of particular interest is an example where {G_{2 × 2}}, the two-dimensional restriction of G, is flat but the plate still exhibits the energy scaling of the Föppl-von Kármán type. Finally, we apply these results to a model of nematic glass, including a characterization of the condition when the metric is immersible, for {G = Id3 + γ n ⊗ n} given in terms of the inhomogeneous unit director field distribution { n in R^3}.

  13. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  14. Hypervelocity impact on shielded plates

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1993-01-01

    A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

  15. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  16. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  17. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  18. Reduced hydrogen cadmium plating

    SciTech Connect

    Hoeller, T.; Ross, L. ); Varma, R. ); Agarwala, V.S. )

    1991-01-01

    This paper demonstrates the advantages of using a periodic reverse pulse plating method, incorporating a fast cathodic pulse which is separated from the subsequent anodic/cathodic pulses by a long rest period in producing silvery cadmium coatings on steel from aqueous fluoroborate electrolyte. Also, the deposition obtained by combination of pulse currents and turbulent electrolyte flow system (forced convection of electrolyte, Re {approximately} 20-25,000) result in a near hydrogen-free electrodeposition of fine- grained cadmium. This is confirmed by the determination of diffusible hydrogen by the electrochemical (Barnach Electrode) method.

  19. Plating on difficult-to-plate metals: what's new

    SciTech Connect

    Wiesner, H.J.

    1980-07-30

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required.

  20. Tectonics of the Easter plate

    NASA Technical Reports Server (NTRS)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  1. Localised Plate Motion on Venus

    NASA Astrophysics Data System (ADS)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  2. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  3. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  4. Multiple plate hydrostatic viscous damper

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  5. Plate heat exchanger design theory

    NASA Astrophysics Data System (ADS)

    Shah, R. K.; Wanniarachchi, A. S.

    Plate heat exchangers are commonly used in hygienic applications as well as in chemical processing and other industrial applications. Pertinent information on plate exchangers from a designer's point of view is summarized to provide a basic insight into performance behavior of chevron plates. Basic design methods are presented and a method of coupling between heat transfer and pressure drop is introduced. A step by step design procedure for rating and sizing problems is outlined.

  6. Channel plate for DNA sequencing

    DOEpatents

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  7. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  8. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  9. Carbon-assisted flyer plates

    DOEpatents

    Stahl, David B.; Paisley, Dennis L.

    1994-01-01

    A laser driven flyer plate utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited.

  10. Intermittent plate tectonics?

    PubMed

    Silver, Paul G; Behn, Mark D

    2008-01-01

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  11. Downgoing plate controls on overriding plate deformation in subduction zones

    NASA Astrophysics Data System (ADS)

    Garel, Fanny; Davies, Rhodri; Goes, Saskia; Davies, Huw; Kramer, Stephan; Wilson, Cian

    2014-05-01

    Although subduction zones are convergent margins, deformation in the upper plate can be extensional or compressional and tends to change through time, sometimes in repeated episodes of strong deformation, e.g, phases of back-arc extension. It is not well understood what factors control this upper plate deformation. We use the code Fluidity, which uses an adaptive mesh and a free-surface formulation, to model a two-plate subduction system in 2-D. The model includes a composite temperature- and stress-dependent rheology, and plates are decoupled by a weak layer, which allows for free trench motion. We investigate the evolution of the state of stress and topography of the overriding plate during the different phases of the subduction process: onset of subduction, free-fall sinking in the upper mantle and interaction of the slab with the transition zone, here represented by a viscosity contrast between upper and lower mantle. We focus on (i) how overriding plate deformation varies with subducting plate age; (ii) how spontaneous and episodic back-arc spreading develops for some subduction settings; (iii) the correlation between overriding plate deformation and slab interaction with the transition zone; (iv) whether these trends resemble observations on Earth.

  12. 10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: 1889, BUILT BY THE BERLIN IRON BRIDGE CO. EAST BERLIN CONN. DOUGLAS & JARVIS PAT. APT. 16, 1878, AP'L 17, 1885. A.P. FORESMAN, WM. S. STARR, T.J. STREBEIGH, COMMISSIONERS. - Pine Creek Bridge, River Road spanning Pine Creek, Jersey Shore, Lycoming County, PA

  13. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2010-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4+27 kg m2 s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies revealed by geoid anomalies of the degree 4-10 packet of the Earth's spherical harmonic coefficients. These linear positive geoid anomalies underlie plate subduction zones and are presumed due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant

  14. Plate tectonics, damage and inheritance

    NASA Astrophysics Data System (ADS)

    Bercovici, David; Ricard, Yanick

    2014-04-01

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  15. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates. PMID:24717430

  16. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  17. Micro-channel plate detector

    SciTech Connect

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  18. Metal vapor arc ion plating

    SciTech Connect

    Bertram, L.A.; Fisher, R.W.; Mattox, D.M.; Zanner, F.J.

    1986-09-09

    A method and apparatus for ion plating are described. The apparatus uses more negative than a first electrode voltage in a vacuum arc remelt system to attract low energy ions from the anode electrode to the article to be plated. 2 figs.

  19. Flat-plate heat pipe

    NASA Technical Reports Server (NTRS)

    Marcus, B. D.; Fleischman, G. L. (Inventor)

    1977-01-01

    Flat plate (vapor chamber) heat pipes were made by enclosing metal wicking between two capillary grooved flat panels. These heat pipes provide a unique configuration and have good capacity and conductance capabilities in zero gravity. When these flat plate vapor chamber heat pipes are heated or cooled, the surfaces are essentially isothermal, varying only 3 to 5 C over the panel surface.

  20. Metals plated on fluorocarbon polymers

    NASA Technical Reports Server (NTRS)

    Ford, H.; Krasinsky, J. B.; Vango, S. P.

    1964-01-01

    Electroplating lead on fluorocarbon polymer parts is accomplished by etching the parts to be plated with sodium, followed by successive depositions of silver and lead from ultrasonically agitated plating solutions. Metals other than lead may be electroplated on the silvered parts.

  1. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  2. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  3. The moving plate capacitor paradox

    NASA Astrophysics Data System (ADS)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2000-03-01

    For the first time we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. A demon restores the plates of the capacitor to their original position, only when the voltage across the capacitor is small—hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the question is how? We explore the concept of a moving plate capacitor, driven by noise, a step further by examining the case where the restoring force on the capacitor plates is provided by a simple spring, rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other.

  4. SAMI Automated Plug Plate Configuration

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.; Farrell, T.; Goodwin, M.

    2013-10-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13×61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  5. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  6. Plate tectonics, damage and inheritance

    NASA Astrophysics Data System (ADS)

    Bercovici, D. A.; Ricard, Y. R.

    2013-12-01

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto subduction about 4Ga, evident in geochemical analysis from ancient cratons, to global tectonics by 3-2.7Ga, suggests that plates and plate boundaries spread globally over a 1Gyr period. We hypothesize that when sufficient lithospheric damage, which promotes shear-localization and long-lived weak zones, combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of plate boundaries and eventually fully formed tectonic plates driven by subduction alone. We demonstrate this process with an idealized model of pressure-driven flow (wherein a low pressure zone is equivalent to downwelling suction or slab pull) in a lithosphere that self-weakens according to a mylonitic-type polycrystalline grain-damage mechanism (Bercovici and Ricard, Phys. Earth Planet. Int. v.202-203, pp27-55, 2012). In the simplest case, for Earth-like conditions, four successive orthogonal rotations of the driving pressure field yield relic damage zones that are inherited to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even as flow is only driven by subduction. For Venus' hotter surface conditions, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which is compatible with observations. After plates are developed, continued changes in driving forces combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor and micro plates.

  7. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  8. Mantle convection with plates and mobile, faulted plate margins.

    PubMed

    Zhong, S; Gurnis, M

    1995-02-10

    A finite-element formulation of faults has been incorporated into time-dependent models of mantle convection with realistic rheology, continents, and phase changes. Realistic tectonic plates naturally form with self-consistent coupling between plate and mantle dynamics. After the initiation of subduction, trenches rapidly roll back with subducted slabs temporarily laid out along the base of the transition zone. After the slabs have penetrated into the lower mantle, the velocity of trench migration decreases markedly. The inhibition of slab penetration into the lower mantle by the 670-kilometer phase change is greatly reduced in these models as compared to models without tectonic plates. PMID:17813909

  9. Difficulties encountered removing locked plates

    PubMed Central

    Raja, S; Imbuldeniya, AM; S, Garg; Groom, G

    2012-01-01

    INTRODUCTION Locked plates are commonly used to obtain fixation in periarticular and comminuted fractures. Their use has also gained popularity in repairing fractures in osteoporotic bone. These plates provide stable fixation and promote biological healing. Over the last 3 years, we have used over 150 locked plates with varying success to fix periarticular fractures involving mainly the knee and ankle. In this study, we report our clinical experience and the difficulties encountered when removing locked plates in adult patients with a variety of indications including implant failure, infection, non-union and a palpable symptomatic implant. METHODS A retrospective analysis was performed of patients enrolled prospectively into a database. Included in the study were 36 consecutive adult patients who each underwent the procedure of locked plate removal in a single inner city level 1 trauma centre. Data collected included primary indication for fixation, indication for implant removal, time of the implant in situ, grade of operating surgeon and difficulties encountered during the procedure. RESULTS Implant removal was associated with a complication rate of 47%. The major problems encountered were difficulty in removing the locked screws and the implant itself. A total of ten cold welded screws were found in eight cases. Removal was facilitated by high speed metal cutting burrs and screw removal sets in all but one case, where a decision was made to leave the plate in situ. CONCLUSIONS The majority of studies investigating implant removal and problems encountered in doing so report a relatively high complication rate. With the advent of locking plates and their growing popularity, difficulties are now being seen intra-operatively when removing them. There is a paucity of data, however, specifically directed at locking plate removal. We recommend that surgeons should be aware of the potential complications while removing locked plates. Fluoroscopic control and all

  10. The concept of locking plates.

    PubMed

    Cronier, P; Pietu, G; Dujardin, C; Bigorre, N; Ducellier, F; Gerard, R

    2010-05-01

    After a short historical review of locking bone plates since their inception more than a century ago to the success of the concept less than 15 years ago with today's plates, the authors present the main locking mechanisms in use. In the two broad categories - plates with fixed angulation and those with variable angulation - the screw head is locked in the plate with a locknut by screwing in a threaded chamber on the plate or by screwing through an adapted ring. The authors then provide a concrete explanation, based on simple mechanical models, of the fundamental differences between conventional bone plates and locking plates and why a locking screw system presents greater resistance at disassembly, detailing the role played by the position and number of screws. The advantages of epiphyseal fixation are then discussed, including in cases of mediocre-quality bone. For teaching purposes, the authors also present assembly with an apple fixed with five locking screws withstanding a 47-kg axial load with no resulting disassembly. The principles of plate placement are detailed for both the epiphysis and diaphysis, including the number and position of screws and respect of the soft tissues, with the greatest success assured by the minimally invasive and even percutaneous techniques. The authors then present the advantages of locking plates in fixation of periprosthetic fractures where conventional osteosynthesis often encounters limited success. Based on simplified theoretical cases, the economic impact in France of this type of implant is discussed, showing that on average it accounts for less than 10% of the overall cost of this pathology to society. Finally, the possible problems of material ablation are discussed as well as the means to remediate these problems.

  11. High loading uranium fuel plate

    DOEpatents

    Wiencek, Thomas C.; Domagala, Robert F.; Thresh, Henry R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  12. Carbon-assisted flyer plates

    DOEpatents

    Stahl, D.B.; Paisley, D.L.

    1994-04-12

    A laser driven flyer plate is described utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited. 2 figures.

  13. The multigap resistive plate chamber

    SciTech Connect

    Zeballos, E. Cerron; Crotty, I.; Hatzifotiadou, D.; Valverde, J. Lamas; Neupane, S.; Williams, M. C. S.; Zichichi, A.

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  14. Tectonics: Changing of the plates

    NASA Astrophysics Data System (ADS)

    Brandon, Alan

    2016-10-01

    The composition of Earth's crust depends on the style of plate tectonics and of the melting regimes in the mantle. Analyses of the oldest identified rocks suggest that these styles and the resulting crust have changed over Earth's history.

  15. Quaternions as astrometric plate constants

    NASA Technical Reports Server (NTRS)

    Jefferys, William H.

    1987-01-01

    A new method for solving problems in relative astrometry is proposed. In it, the relationship between the measured quantities and the components of the position vector of a star is modeled using quaternions, in effect replacing the plate constants of a standard four-plate-constant solution with the four components of a quaternion. The method allows a direct solution for the position vectors of the stars, and hence for the equatorial coordinates. Distortions, magnitude, and color effects are readily incorporated into the formalism, and the method is directly applicable to overlapping-plate problems. The advantages of the method include the simplicity of the resulting equations, their freedom from singularities, and the fact that trigonometric functions and tangential point transformations are not needed to model the plate material. A global solution over the entire sky is possible.

  16. Pulse plating of nickel deposits

    SciTech Connect

    Stimetz, C.J.; Stevenson, M.F.

    1980-02-01

    Pulse plated and conventional nickel deposits have been compared for differences in morphology, mechanical properties, and microstructure. The deposits were obtained from nickel sulfamate, nickel chloride, and Watts nickel plating solutions. No significant differences were found in the direct and pulse current deposits from the sulfamate and chloride solutions; however, significant differences in microstructure, yield strength, and microhardness were observed in deposits from the Watts nickel solution.

  17. Impact on multilayered composite plates

    NASA Technical Reports Server (NTRS)

    Kim, B. S.; Moon, F. C.

    1977-01-01

    Stress wave propagation in a multilayer composite plate due to impact was examined by means of the anisotropic elasticity theory. The plate was modelled as a number of identical anisotropic layers and the approximate plate theory of Mindlin was then applied to each layer to obtain a set of difference-differential equations of motion. Dispersion relations for harmonic waves and correction factors were found. The governing equations were reduced to difference equations via integral transforms. With given impact boundary conditions these equations were solved for an arbitrary number of layers in the plate and the transient propagation of waves was calculated by means of a Fast Fourier Transform algorithm. The multilayered plate problem was extended to examine the effect of damping layers present between two elastic layers. A reduction of the interlaminar normal stress was significant when the thickness of damping layer was increased but the effect was mostly due to the softness of the damping layer. Finally, the problem of a composite plate with a crack on the interlaminar boundary was formulated.

  18. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-01

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction. PMID:12364804

  19. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-01

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction.

  20. Geometry of the Cocos Plate Under North American Plate

    NASA Astrophysics Data System (ADS)

    Perez-Campos, X.

    2015-12-01

    The Cocos plate subducts under the North American plate with a complex geometry, and previous seismicity studies revealed some of this complexity. However, details of the geometry and the depth that the plate penetrates werelargely unknown. Since 2004, temporary experiments and the expansion of the permanent network of the Servicio Sismológico Nacional (SSN, Mexican National Seismological Service) have improved resolution of the plate geometry and have helped to map its descent into the upper mantle. Going from northwest to southeast, the Cocos plate appears to be fragmenting into north and south segments. The north segment subducts with an angle of ~30º and the south with an angle of ~10-15º. The transition is smooth near the trench and progresses to a tear at depth; this coincides with the projection of the Orozco Fracture Zone to depth. Also, this transition marks the limit of the presence to the south of an ultra slow velocity layer (USL) on top of the slab.South of this transition, the Cocos plate subducts horizontally , underplating the North American plate for a distance of ~140 to ~300 km from the trench. Along this horizontal region, silent slow events (SSE) and tectonic tremor (TT) have been observed. At a distance of 300 km from the trench (beneath central Mexico), the plate dives into the mantle with an angle of 76º to a depth of 500 km. This geometry changes abruptly to the south, marking the eastern limit of the USL. This change seems to be also characterized by a tear on the slab. Finally to the south, the Cocos plate subducts with a constant angle of 26º. This presentation summarizes the work of many contributors including A. Arciniega-Ceballos, M. Brudzinski, E. Cabral-Cano, T. Chen, R. Clayton,F. Cordoba-Montiel,P. Davis,S. Dougherty,F. Green, M. Gurnis, D. V. Helmberger, A. Husker,A. Iglesias, Y. Kim, V. Manea, D. Melgar, M. Rodríguez-Domínguez,S. K. Singh, T.-R. A. Song, C. M. Valdés-González, D. Valencia-Cabrera

  1. Plate mode velocities in graphite/epoxy plates

    NASA Technical Reports Server (NTRS)

    Prosser, W. H.; Gorman, M. R.

    1994-01-01

    Measurements of the velocities of the extensional and flexural plate modes were made along three directions of propagation in four graphite/epoxy composite plates. The acoustic signals were generated by simulated acoustic emission events (pencil lead breaks or Hsu-Neilson sources) and detected by by broadband ultrasonic transducers. The first arrival of the extensional plate mode, which is nondispersive at low frequencies, was measured at a number of different distances from the source along the propagation direction of interest. The velocity was determined by plotting the distance versus arrival time and computing its slope. Because of the large dispersion of the flexural mode, a Fourier phase velocity technique was used to characterize this mode. The velocity was measured up to a frequency of 160 kHz. Theoretical predictions of the velocities of these modes were also made and compared with experimental observations. Classical plate theory yields good agreement with the measured extensional velocities. For predictions of the dispersion of the flexural mode, Mindlin plates theory, which includes the effects of shear deformation and rotatory inertia was shown to give better agreement with the experimental measurements.

  2. Plate tectonics of the Mediterranean region.

    PubMed

    McKenzie, D P

    1970-04-18

    The seismicity and fault plane solutions in the Mediterranean area show that two small rapidly moving plates exist in the Eastern Mediterranean, and such plates may be a common feature of contracting ocean basins. The results show that the concepts of plate tectonics apply to instantaneous motions across continental plate boundaries. PMID:16057188

  3. Electrodeposition process reduces cost of cold plates

    NASA Technical Reports Server (NTRS)

    Ruppe, E. P.

    1980-01-01

    Efficient nickel heat-exchanger cold plates can be fabricated less expensively than stainless steel plates. If adapted to mass production, it is estimated that nickel cold plates might be made for about 30 percent less than stainless-steel plates.

  4. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  5. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  6. Plate tectonics of the Mediterranean region.

    PubMed

    McKenzie, D P

    1970-04-18

    The seismicity and fault plane solutions in the Mediterranean area show that two small rapidly moving plates exist in the Eastern Mediterranean, and such plates may be a common feature of contracting ocean basins. The results show that the concepts of plate tectonics apply to instantaneous motions across continental plate boundaries.

  7. Beyond plate tectonics - Looking at plate deformation with space geodesy

    NASA Technical Reports Server (NTRS)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  8. Plating on some difficult-to-plate metals and alloys

    SciTech Connect

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests.

  9. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  10. Multiregional evaluation of the SimPlate heterotrophic plate count method compared to the standard plate count agar pour plate method in water.

    PubMed

    Jackson, R W; Osborne, K; Barnes, G; Jolliff, C; Zamani, D; Roll, B; Stillings, A; Herzog, D; Cannon, S; Loveland, S

    2000-01-01

    A new SimPlate heterotrophic plate count (HPC) method (IDEXX Laboratories, Westbrook, Maine) was compared with the pour plate method at 35 degrees C for 48 h. Six laboratories tested a total of 632 water samples. The SimPlate HPC method was found to be equivalent to the pour plate method by regression analysis (r = 0. 95; y = 0.99X + 0.06).

  11. Insert metering plates for gas turbine nozzles

    DOEpatents

    Burdgick, Steven S.; Itzel, Gary; Chopra, Sanjay; Abuaf, Nesim; Correia, Victor H.

    2004-05-11

    The invention comprises a metering plate which is assembled to an impingement insert for use in the nozzle of a gas turbine. The metering plate can have one or more metering holes and is used to balance the cooling flow within the nozzle. A metering plate with multiple holes reduces static pressure variations which result from the cooling airflow through the metering plate. The metering plate can be assembled to the insert before or after the insert is inserted into the nozzle.

  12. Elastoacoustic response of laminated plates

    NASA Astrophysics Data System (ADS)

    Kolar, Ramesh

    2005-04-01

    The application of composite materials in the aerospace and naval structures has increased enormously due to high specific strength and specific stiffness afforded by these materials. In this paper a formulation is developed based on Hamilton's Principle and laminated composite plate theory to study the elasto-acoustical response of composite plates under heavy fluid loadings. The formulation starts by using Hamilton's principle in conjunction with shear deformable theory of laminated composite plates. The acoustic pressure described by wave equation is computed similar to Sandman and Nelisse. Using the Rayleigh Ritz method and symbolic mathematics for evaluation of integrals, the formulation provides efficient approach for the problem defined. Typical results include radiation impedance as a function of driving frequency, vibroacoustic indicators such as radiated sound power and mean square velocity for a model problem. Such results are very important in studying constrained layer damping when viscolastic dampers are used in structural components.

  13. Plate-like osteoma cutis.

    PubMed

    Orme, Charisse M; Hale, Christopher S; Meehan, Shane A; Long, Wendy

    2014-12-16

    Osteoma cutis is the aberrant development of bone within the skin. The bone formation may be de novo (primary) or result from an injury to the skin (secondary). Here we present a healthy 53-year-old man with no known abnormalities in calcium or phosphate metabolism with plate-like osteoma cutis of the scalp. Plate- or plaque-like osteoma cutis was initially described as a congenital condition but has now been reported several times in the literature as an idiopathic process that occurs in adults. Treatment options are limited and are only required if the lesion is bothersome to the patient.

  14. License Plate Recognition System for Indian Vehicles

    NASA Astrophysics Data System (ADS)

    Sanap, P. R.; Narote, S. P.

    2010-11-01

    We consider the task of recognition of Indian vehicle number plates (also called license plates or registration plates in other countries). A system for Indian number plate recognition must cope with wide variations in the appearance of the plates. Each state uses its own range of designs with font variations between the designs. Also, vehicle owners may place the plates inside glass covered frames or use plates made of nonstandard materials. These issues compound the complexity of automatic number plate recognition, making existing approaches inadequate. We have developed a system that incorporates a novel combination of image processing and artificial neural network technologies to successfully locate and read Indian vehicle number plates in digital images. Commercial application of the system is envisaged.

  15. Corrosion resistant metallic bipolar plate

    DOEpatents

    Brady, Michael P.; Schneibel, Joachim H.; Pint, Bruce A.; Maziasz, Philip J.

    2007-05-01

    A corrosion resistant, electrically conductive component such as a bipolar plate for a PEM fuel cell includes 20 55% Cr, balance base metal such as Ni, Fe, or Co, the component having thereon a substantially external, continuous layer of chromium nitride.

  16. Petroleum occurrences and plate tectonics

    SciTech Connect

    Olenin, V.B.; Sokolov, B.A.

    1983-01-01

    This paper analyzes the mechanisms of petroleum formation and petroleum accumulation proposed in recent years by some Russian and foreign investigators from the viewpoint of the new global or plate tectonics. On the basis of discussion and the facts, the authors conclude that the mechanisms proposed are in contradiction to reality and their use in practical application is at least premature.

  17. Comment on "Intermittent plate tectonics?".

    PubMed

    Korenaga, Jun

    2008-06-01

    Silver and Behn (Reports, 4 January 2008, p. 85) proposed that intermittent plate tectonics may resolve a long-standing paradox in Earth's thermal evolution. However, their analysis misses one important term, which subsequently brings their main conclusion into question. In addition, the Phanerozoic eustasy record indicates that the claimed effect of intermittency is probably weak.

  18. Troubleshooting plated-wire memories

    NASA Technical Reports Server (NTRS)

    Baker, C. M.; Bright, T. M.; Constable, R. C.

    1979-01-01

    Faults in plated wire memories are identified and located from outside of system by applying electrical impulses and analyzing their reflectance in technique of Time-Domain Reflectometry (TDR). Intermittent faults are easier to find because memory system is not disturbed by probing or disassembly.

  19. The seismotectonics of plate boundaries

    NASA Technical Reports Server (NTRS)

    Berger, J.; Brune, J. N.; Goodkind, J.; Wyatt, F.; Agnew, D. C.; Beaumont, C.

    1981-01-01

    Research on the seismotectonics of plate boundaries is summarized. Instrumental development and an observational program designed to study various aspects of the seismotectonics of southern California and the northern Gulf of California are described. A unique superconducting gravimeter was further developed and supported under this program for deployment and operation at several sites. Work on Earth tides is also discussed.

  20. Plated wire random access memories

    NASA Technical Reports Server (NTRS)

    Gouldin, L. D.

    1975-01-01

    A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.

  1. Double-Plate Penetration Equations

    NASA Technical Reports Server (NTRS)

    Hayashida, K. B.; Robinson, J. H.

    2000-01-01

    This report compares seven double-plate penetration predictor equations for accuracy and effectiveness of a shield design. Three of the seven are the Johnson Space Center original, modified, and new Cour-Palais equations. The other four are the Nysmith, Lundeberg-Stern-Bristow, Burch, and Wilkinson equations. These equations, except the Wilkinson equation, were derived from test results, with the velocities ranging up to 8 km/sec. Spreadsheet software calculated the projectile diameters for various velocities for the different equations. The results were plotted on projectile diameter versus velocity graphs for the expected orbital debris impact velocities ranging from 2 to 15 km/sec. The new Cour-Palais double-plate penetration equation was compared to the modified Cour-Palais single-plate penetration equation. Then the predictions from each of the seven double-plate penetration equations were compared to each other for a chosen shield design. Finally, these results from the equations were compared with test results performed at the NASA Marshall Space Flight Center. Because the different equations predict a wide range of projectile diameters at any given velocity, it is very difficult to choose the "right" prediction equation for shield configurations other than those exactly used in the equations' development. Although developed for various materials, the penetration equations alone cannot be relied upon to accurately predict the effectiveness of a shield without using hypervelocity impact tests to verify the design.

  2. Consecutive plate acoustic suppressor apparatus and methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony (Inventor)

    1992-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  3. Consecutive Plate Acoustic Suppressor Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony L. (Inventor)

    1993-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  4. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  5. Evaluation of an automated agar plate streaker.

    PubMed Central

    Tilton, R C; Ryan, R W

    1978-01-01

    An automated agar plate streaker was evaluated. The Autostreaker mechanizes the agar plate streaking process by providing storage for plates, labeling and streaking one or more plates for either isolation or quantitation, and stacking in one of several racks for subsequent incubation. Results showed the Autostreaker to produce agar plates with well-separated colonies and accurate colony counts. A total of 1,930 clinical specimens were processed either in parallel with manual methods or solely by the Autostreaker. Technologist acceptance of machine-streaked plates was outstanding. Images PMID:348722

  6. Development of Reduction Technique of Thermal Stress Induced in Steel Plate Bonded by CFRP Plates

    NASA Astrophysics Data System (ADS)

    Ishikawa, Toshiyuki; Hattori, Atsushi; Kawano, Hirotaka; Nagao, Takashi; Kobayashi, Akira

    In CFRP bonded onto steel plate, thermal stress is induced in steel plate by temperature change, due to difference in coefficients of thermal expansion between steel and CFRP. In this study, reduction technique of the thermal stress in steel plate, which is additional bonding of aluminum alloy plates, is proposed. Namely, the coefficient of thermal expansion of composite plate consisted of CFRP and aluminum plates is designed as that of steel. In this research, to verify the effectiveness of developed method, heat tests of CFRP and aluminum plates bonded onto steel plate were carried out. As a result of the tests, infinitesimal thermal stresses in steel plate with CFRP and aluminum plates were measured while large thermal stresses were measured in conventional CFRP bonded onto steel plate. Additionally, to confirm the test results, numerical analysis was also carried out.

  7. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5 track where timber crossties are in use there shall be tie plates under the running rails on at least eight...

  8. Epiphyseal plate transplantation: an historical review.

    PubMed

    Boyer, M I; Bray, P W; Bowen, C V

    1994-12-01

    Non-vascularized and vascularized transplantation of epiphyseal plate autografts have been performed both clinically and experimentally for over 100 years. However, the ultimate clinical goal of vascularized transplantation of epiphyseal plate allografts for paediatric extremity reconstruction remains elusive, due primarily to the lack of suitably nontoxic techniques to prevent graft rejection. We have summarized the published clinical and experimental investigations of vascularized epiphyseal plate transplantation, and organized the experiments and clinical operations into four main groups: (1) local vascular studies on unmanipulated epiphyseal plates, (2) studies of epiphyseal plate behaviour after orthotopic replantation, (3) studies of epiphyseal plate behaviour after heterotopic transplantation, and (4) studies of epiphyseal plate behaviour after allograft transplantation. Prior investigations into the non-vascularized transplantation of epiphyseal plate autografts and allografts are presented as background. These groups of studies serve as the building blocks for the more clinically applicable experimental investigations outlined in the final section of this review. PMID:7697285

  9. Maps, Plates, and Mount Saint Helens.

    ERIC Educational Resources Information Center

    Lary, Barbara E.; Krockover, Gerald H.

    1987-01-01

    Describes a laboratory activity on plate tectonics which focuses on the connection between plate tectonics and the different types of volcanoes. Provides questions for discussion and includes suggestions for extending the activity. (ML)

  10. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  11. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, P.J.

    1987-03-02

    A method of electrically inducing mechanical precompression of ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion. 2 figs.

  12. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, Peter J.

    1987-01-01

    A method of electrically inducing mechanical precompression of a ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion.

  13. Axisymmetric vibrations of layered tapered plates

    NASA Astrophysics Data System (ADS)

    Navaneethakrishnan, P. V.; Chandrasekaran, K.; Ravisrinivas, N.

    1992-12-01

    The study of Navaneethakrishnan and Chandrasekaran (1989) on axisymmetric free vibrations of layered annular plates is extended to the vibrations of layered annular plates whose thickness can vary as the radial distance from the arbitrary concentric circle. Numerical results are presented, showing the relationship between the circular frequency of the plate vibration and the ratio between the inner and the outer radii of the plate.

  14. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  15. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1984-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  16. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1986-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  17. Electroless metal plating of plastics

    DOEpatents

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  18. Ion plated electronic tube device

    DOEpatents

    Meek, T.T.

    1983-10-18

    An electronic tube and associated circuitry which is produced by ion plating techniques. The process is carried out in an automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

  19. Syncytial-Type Cell Plates

    PubMed Central

    Otegui, Marisa; Staehelin, L. Andrew

    2000-01-01

    Cell wall formation in the syncytial endosperm of Arabidopsis was studied by using high-pressure-frozen/freeze-substituted developing seeds and immunocytochemical techniques. The endosperm cellularization process begins at the late globular embryo stage with the synchronous organization of small clusters of oppositely oriented microtubules (∼10 microtubules in each set) into phragmoplast-like structures termed mini-phragmoplasts between both sister and nonsister nuclei. These mini-phragmoplasts produce a novel kind of cell plate, the syncytial-type cell plate, from Golgi-derived vesicles ∼63 nm in diameter, which fuse by way of hourglass-shaped intermediates into wide (∼45 nm in diameter) tubules. These wide tubules quickly become coated and surrounded by a ribosome-excluding matrix; as they grow, they branch and fuse with each other to form wide tubular networks. The mini-phragmoplasts formed between a given pair of nuclei produce aligned tubular networks that grow centrifugally until they merge into a coherent wide tubular network with the mini-phragmoplasts positioned along the network margins. The individual wide tubular networks expand laterally until they meet and eventually fuse with each other at the sites of the future cell corners. Transformation of the wide tubular networks into noncoated, thin (∼27 nm in diameter) tubular networks begins at multiple sites and coincides with the appearance of clathrin-coated budding structures. After fusion with the syncytial cell wall, the thin tubular networks are converted into fenestrated sheets and cell walls. Immunolabeling experiments show that the cell plates and cell walls of the endosperm differ from those of the embryo and maternal tissue in two features: their xyloglucans lack terminal fucose residues on the side chain, and callose persists in the cell walls after the cell plates fuse with the parental plasma membrane. The lack of terminal fucose residues on xyloglucans suggests that these cell wall

  20. PRETREATING URANIUM FOR METAL PLATING

    DOEpatents

    Wehrmann, R.F.

    1961-05-01

    A process is given for anodically treating the surface of uranium articles, prior to metal plating. The metal is electrolyzed in an aqueous solution of about 10% polycarboxylic acid, preferably oxalic acid, from 1 to 5% by weight of glycerine and from 1 to 5% by weight of hydrochloric acid at from 20 to 75 deg C for from 30 seconds to 15 minutes. A current density of from 60 to 100 amperes per square foot is used.

  1. Episodic plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  2. Volcano spacing and plate rigidity

    SciTech Connect

    Brink, U. )

    1991-04-01

    In-plane stresses, which accompany the flexural deformation of the lithosphere under the load adjacent volcanoes, may govern the spacing of volcanoes in hotspot provinces. Specifically, compressive stresses in the vicinity of a volcano prevent new upwelling in this area, forcing a new volcano to develop at a minimum distance that is equal to the distance in which the radial stresses change from compressional to tensile (the inflection point). If a volcano is modeled as a point load on a thin elastic plate, then the distance to the inflection point is proportional to the thickness of the plate to the power of 3/4. Compilation of volcano spacing in seven volcanic groups in East Africa and seven volcanic groups of oceanic hotspots shows significant correlation with the elastic thickness of the plate and matches the calculated distance to the inflection point. In contrast, volcano spacing in island arcs and over subduction zones is fairly uniform and is much larger than predicted by the distance to the inflection point, reflecting differences in the geometry of the source and the upwelling areas.

  3. MTR plates modeling with MAIA

    SciTech Connect

    Marelle, V.; Dubois, S.; Ripert, M.; Noirot, J.

    2008-07-15

    MAIA is a thermo-mechanical code dedicated to the modeling of MTR fuel plates. The main physical phenomena modeled in the code are the cladding oxidation, the interaction between fuel and Al-matrix, the swelling due to fission products and the Al/fuel particles interaction. The creeping of the plate can be modeled in the mechanical calculation. MAIA has been validated on U-Mo dispersion fuel experiments such as IRIS 1 and 2 and FUTURE. The results are in rather good agreement with post-irradiation examinations. MAIA can also be used to calculate in-pile behavior of U{sub 3}Si{sub 2} plates as in the SHARE experiment irradiated in the SCK/Mol BR2 reactor. The main outputs given by MAIA throughout the irradiation are temperatures, cladding oxidation thickness, interaction thickness, volume fraction of meat constituents, swelling, displacements, strains and stresses. MAIA is originally a two-dimensional code but a three-dimensional version is currently under development. (author)

  4. Plating of proximal humeral fractures.

    PubMed

    Martetschläger, Frank; Siebenlist, Sebastian; Weier, Michael; Sandmann, Gunther; Ahrens, Philipp; Braun, Karl; Elser, Florian; Stöckle, Ulrich; Freude, Thomas

    2012-11-01

    The optimal treatment for proximal humeral fractures is controversial. Few data exist concerning the influence of the surgical approach on the outcome. The purpose of this study was to evaluate the clinical and radiological outcomes of proximal humeral fractures treated with locking plate fixation through a deltopectoral vs an anterolateral deltoid-splitting approach. Of 86 patients who met the inclusion criteria, 70 were available for follow-up examination. Thirty-three patients were treated through a deltopectoral approach and 37 through an anterolateral deltoid-splitting approach. In all cases, open reduction and internal fixation with a PHILOS locking plate (Synthes, Umkirch, Germany) was performed. Clinical follow-up included evaluation of pain, shoulder mobility, and strength. Constant score and Disabilities of the Arm, Shoulder and Hand (DASH) score were assessed. A clinical neurological examination of the axillary nerve was also performed. Consolidation, reduction, and appearance of head necrosis were evaluated radiographically. After a mean follow-up of 33 months, Constant scores, DASH scores, and American Shoulder and Elbow Surgeons scores showed no significant differences between the groups. Clinical neurologic examination of the axillary nerve revealed no obvious damage to the nerve in either group. Deltopectoral and anterolateral detoid-splitting approaches for plate fixation of proximal humeral fractures are safe and provide similar clinical outcomes. The results of this study suggest that the approach can be chosen according to surgeon preference.

  5. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  6. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  7. Moving Divertor Plates in a Tokamak

    SciTech Connect

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  8. Apparatus and method for controlling plating uniformity

    DOEpatents

    Hachman Jr., John T.; Kelly, James J.; West, Alan C.

    2004-10-12

    The use of an insulating shield for improving the current distribution in an electrochemical plating bath is disclosed. Numerical analysis is used to evaluate the influence of shield shape and position on plating uniformity. Simulation results are compared to experimental data for nickel deposition from a nickel--sulfamate bath. The shield is shown to improve the average current density at a plating surface.

  9. FASTENER FOR AN ASSEMBLY OF PLATES

    DOEpatents

    Groh, E.F.

    1963-08-20

    A fastener is provided for a spaced-apart parallel plate fuel assembly. The fastener, attached by screws to a key that passes through the edges of the assembled plate, serves as a retainer for the outermost plate as well as a bidirectional spacer for separating the fuel assembly from two neighboring fuel assemblies. (AEC)

  10. Recent plate motions and crustal deformation

    SciTech Connect

    Lisowski, M. )

    1991-01-01

    Reports by U.S. workers on geodetic measurements of recent plate motions or crustal deformation published in 1987-1990 are reviewed. The review begins with global plate motions, proceeds through plate boundaries in California, Alaska, and the Pacific Northwest, and finishes with volcanic phenomena, monument stability and longevity, and GPS relative position measurements. 184 refs.

  11. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  12. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  13. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  14. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  15. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  16. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  17. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  18. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  19. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  20. Plate tectonics, habitability and life

    NASA Astrophysics Data System (ADS)

    Spohn, Tilman; Breuer, Doris

    2016-04-01

    The role of plate tectonics in defining habitability of terrestrial planets is being increasingly discussed (e.g., Elkins-Tanton, 2015). Plate tectonics is a significantly evolved concept with a large variety of aspects. In the present context, cycling of material between near surface and mantle reservoirs is most important. But increased heat transport through mixing of cold lithosphere with the deep interior and formation of continental crust may also matter. An alternative mechanism of material cycling between these reservoirs is hot-spot volcanism combined with crust delamination. Hot-spot volcanism will transport volatiles to the atmosphere while delamination will mix crust, possibly altered by sedimentation and chemical reactions, with the mantle. The mechanism works as long as the stagnant lithosphere plate has not grown thicker than the crust and as long as volcanic material is added onto the crust. Thermal evolution studies suggest that the mechanism could work for the first 1-2 Ga of planetary evolution. The efficiency of the mechanism is limited by the ratio of extrusive to intrusive volcanism, which is thought to be less than 0.25. Plate tectonics would certainly have an advantage by working even for more evolved planets. A simple, most-used concept of habitability requires the thermodynamic stability of liquid water on the surface of a planet. Cycling of CO2between the atmosphere, oceans and interior through subduction and surface volcanism is an important element of the carbonate-silicate cycle, a thermostat feedback cycle that will keep the atmosphere from entering into a runaway greenhouse. Calculations for a model Earth lacking plate tectonics but degassing CO2, N, and H2O to form a surface ocean and a secondary atmosphere (Tosi et al, 2016) suggest that liquid water can be maintained on the surface for 4.5Ga. The model planet would then qualify as habitable. It is conceivable that the CO2 buffering capability of its ocean together with silicate

  1. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  2. Quantum levitation of a thin magnetodielectric plate on a metallic plate using the repulsive Casimir force

    NASA Astrophysics Data System (ADS)

    Inui, Norio

    2012-04-01

    Levitation of a thin magnetodielectric plate on a metallic plate by using the repulsive Casimir force is theoretically considered. If the permittivity of the metallic plate near zero frequency is expressed by a plasma model and the static permeability of the magnetodielectric plate is higher than its static permittivity, the Casimir force between the magnetodielectric plate and the metallic plate changes from attractive to repulsive as the separation between them increases. Furthermore, as the thickness of the magnetodielectric plate is decreased, the attractive component of the Casimir force decreases more than the repulsive one. This effect generates a larger repulsive Casimir force as compared with that between the plates having infinite thickness. Combined with the effect of decreasing the weight of the plate, this might enable a thin plate to levitate in vacuum. The height of quantum levitation is evaluated for a combination of yttrium iron garnet and gold.

  3. Steady state response of unsymmetrically laminated plates

    SciTech Connect

    Hosokawa, Kenji; Kawashima, Katsuya; Sakata, Toshiyuki

    1995-11-01

    A numerical approach for analyzing the forced vibration problem of a symmetrically laminated FRP (fiber reinforced plastic) composite plate was proposed by the authors. In the present paper, this approach is modified for application to an unsymmetrically laminated FRP composite plate. Numerical calculations are carried out for the clamped antisymmetrically laminated rectangular and elliptical plates which are a kind of unsymmetrically laminated plate. Then,, the effects of the lamina material and the fiber orientation angle on the steady state response are discussed. Furthermore, it is investigated that what structural damping factor is most influenced on the steady state response of an antisymmetrically laminated plate.

  4. Wheelspace windage cover plate for turbine

    DOEpatents

    Lathrop, Norman Douglas

    2002-01-01

    Windage cover plates are secured between the wheels and spacer of a turbine rotor to prevent hot flow path gas ingestion into the wheelspace cavities. Each cover plate includes a linear, axially extending body curved circumferentially with a radially outwardly directed wall at one axial end. The wall defines a axially opening recess for receiving a dovetail lug. The cover plate includes an axially extending tongue received in a circumferential groove of the spacer. The cover plate is secured with the tongue in the groove and dovetail lug in the recess. Lap joints between circumferentially adjacent cover plates are provided.

  5. Separator plate for a fuel cell

    DOEpatents

    Petri, R.J.; Meek, J.; Bachta, R.P.; Marianowski, L.G.

    1996-04-02

    A separator plate is described for a fuel cell comprising an anode current collector, a cathode current collector and a main plate, the main plate disposed between the anode current collector and the cathode current collector. The anode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the anode side of the separator plate and the cathode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the cathode side of the separator plate. In this manner, the number of components required to manufacture and assemble a fuel cell stack is reduced. 9 figs.

  6. Separator plate for a fuel cell

    DOEpatents

    Petri, Randy J.; Meek, John; Bachta, Robert P.; Marianowski, Leonard G.

    1996-01-01

    A separator plate for a fuel cell comprising an anode current collector, a cathode current collector and a main plate, the main plate disposed between the anode current collector and the cathode current collector. The anode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the anode side of the separator plate and the cathode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the cathode side of the separator plate. In this manner, the number of components required to manufacture and assemble a fuel cell stack is reduced.

  7. Absolute Plate Velocities from Seismic Anisotropy

    NASA Astrophysics Data System (ADS)

    Kreemer, Corné; Zheng, Lin; Gordon, Richard

    2015-04-01

    The orientation of seismic anisotropy inferred beneath plate interiors may provide a means to estimate the motions of the plate relative to the sub-asthenospheric mantle. Here we analyze two global sets of shear-wave splitting data, that of Kreemer [2009] and an updated and expanded data set, to estimate plate motions and to better understand the dispersion of the data, correlations in the errors, and their relation to plate speed. We also explore the effect of using geologically current plate velocities (i.e., the MORVEL set of angular velocities [DeMets et al. 2010]) compared with geodetically current plate velocities (i.e., the GSRM v1.2 angular velocities [Kreemer et al. 2014]). We demonstrate that the errors in plate motion azimuths inferred from shear-wave splitting beneath any one tectonic plate are correlated with the errors of other azimuths from the same plate. To account for these correlations, we adopt a two-tier analysis: First, find the pole of rotation and confidence limits for each plate individually. Second, solve for the best fit to these poles while constraining relative plate angular velocities to consistency with the MORVEL relative plate angular velocities. The SKS-MORVEL absolute plate angular velocities (based on the Kreemer [2009] data set) are determined from the poles from eight plates weighted proportionally to the root-mean-square velocity of each plate. SKS-MORVEL indicates that eight plates (Amur, Antarctica, Caribbean, Eurasia, Lwandle, Somalia, Sundaland, and Yangtze) have angular velocities that differ insignificantly from zero. The net rotation of the lithosphere is 0.25±0.11° Ma-1 (95% confidence limits) right-handed about 57.1°S, 68.6°E. The within-plate dispersion of seismic anisotropy for oceanic lithosphere (σ=19.2° ) differs insignificantly from that for continental lithosphere (σ=21.6° ). The between-plate dispersion, however, is significantly smaller for oceanic lithosphere (σ=7.4° ) than for continental

  8. Photostimulated luminescence properties of neutron image plates

    NASA Astrophysics Data System (ADS)

    Popov, A. I.; Zimmermann, J.; McIntyre, G. J.; Wilkinson, C.

    2016-09-01

    The luminescence properties of two commercial neutron-sensitive image-plates based on Gd2O3-doped BaFBr:Eu2+ storage phosphors are examined. These are white Fuji plates and blue Fuji plates (BAS-ND) with Gd2O3 content by weight of 34% and 50%, respectively. Both plates show two maxima in the photostimulation spectrum near 500 nm and 600 nm, with the ratio of the peak responses (I600 nm/I500 nm) 1.39 and 0.53 for the white and blue plates respectively. The optimum wavelengths for photostimulation for the two phosphors are therefore different. The response of the blue plate is only 25% that of the white plate, if each is stimulated at its optimum wavelength.

  9. Astronomical Photographic Plate Collections: Treasure or Trash?

    NASA Astrophysics Data System (ADS)

    Osborn, W. H.; Castelaz, M. W.; Cline, J. D.

    2005-12-01

    Our efforts over the past three years to establish a national archive for astronomical plates will be described. This work has led to the following major conclusions regarding the preservation of astronomical photographic plates: (1) a significant number of observatories, as well as retiring astronomers, wish to dispose of the plates they hold; (2) most astronomers feel direct and spectroscopic plates of potential scientific value should be preserved; (3) there is little interest in providing support for preservation efforts on a broad scale. We offer that the astronomical community must quickly decide to preserve plate collections or they will soon be lost, either consciously discarded or through benign neglect. If a systematic effort to preserve these archival data is indeed to be made, priorities need to be established. Not only is archiving (and eventually digitizing) all existing plates impracticable, many plates have little or no potential value. We will present our ideas on priorities and seek the input of the community.

  10. When Did Plate Tectonics Begin

    NASA Astrophysics Data System (ADS)

    Brown, M.

    2015-12-01

    Present-day plate tectonics on Earth is characterized by asymmetric (one-sided) subduction, but how do we recognize the imprint of subduction in the geologic record? How do we weigh global (commonly younger) vs local (commonly older) datasets or distinguish initiation from episodic from continuous subduction? How reliable are data gaps? Characteristics of the Paleozoic record of subduction include calc-alkaline magmatism, blueschist/UHP metamorphism and collisional orogenesis, and ophiolites as representatives of former ocean lithosphere. Are these characteristic rocks preserved in Proterozoic, Archean and Hadean crust? Does a hotter mantle, higher heat production and weaker lithosphere modify or eliminate these features? What preceded subduction and how do we recognize that regime? Are rock associations or geochemical fingerprints reliable? Does reworking and overprinting modify geochemical fingerprints? Proposals for the start of plate tectonics have been based on: persistence of isotope anomalies/fractionated chemical domains in the mantle; changes in chemistry of magmatic rocks, rates of crustal growth vs reworking, and sites of growth; the metamorphic record, particularly the first appearance of contrasting thermal gradients or eclogite (including evidence from mineral inclusions in diamonds) or UHP metamorphic rocks; stabilization of cratonic lithosphere and formation of supercratons, and the beginning of the Proterozoic supercontinent cycle; the end of the flat Earth, emergence of continents, development of significant topography, changes in the style of orogeny and the rise in atmospheric oxygen; and, the appearance of passive margins and changes in the style of sedimentation. Estimates of the timing have varied from the Hadean to Neoproterozoic. I will summarize evidence for a growing consensus that the late Mesoarchean to early Paleoproterozoic was a 700 Myr long period of transition to continuous (?) subduction and global (?) mobile-lid plate tectonics.

  11. Tectonic speed limits from plate kinematic reconstructions

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Müller, R. Dietmar; Seton, Maria; Flament, Nicolas

    2015-05-01

    The motion of plates and continents on the planet's surface are a manifestation of long-term mantle convection and plate tectonics. Present-day plate velocities provide a snapshot of this ongoing process, and have been used to infer controlling factors on the speeds of plates and continents. However, present-day velocities do not capture plate behaviour over geologically representative periods of time. To address this shortcoming, we use a plate tectonic reconstruction approach to extract time-dependent plate velocities and geometries from which root mean square (RMS) velocities are computed, resulting in a median RMS plate speed of ∼ 4 cm /yr over 200 Myr. Linking tectonothermal ages of continental lithosphere to the RMS plate velocity analysis, we find that the increasing portions of plate area composed of continental and/or cratonic lithosphere significantly reduces plate speeds. Plates with any cratonic portion have a median RMS velocity of ∼ 5.8 cm /yr, while plates with more than 25% of cratonic area have a median RMS speed of ∼ 2.8 cm /yr. The fastest plates (∼ 8.5 cm /yr RMS speed) have little continental fraction and tend to be bounded by subduction zones, while the slowest plates (∼ 2.6- 2.8 cm /yr RMS speed) have large continental fractions and usually have little to no subducting part of plate perimeter. More generally, oceanic plates tend to move 2-3 times faster than continental plates, consistent with predictions of numerical models of mantle convection. The slower motion of continental plates is compatible with deep keels impinging on asthenospheric flow and increasing shear traction, thus anchoring the plate in the more viscous mantle transition zone. We also find that short-lived (up to ∼ 10 Myr) rapid accelerations of Africa (∼100 and 65 Ma), North America (∼100 and 55 Ma) and India (∼ 130 , 80 and 65 Ma) appear to be correlated with plume head arrivals as recorded by large igneous province (LIPs) emplacement. By evaluating

  12. Ultrathin plasmonic chiral phase plate.

    PubMed

    Gorodetski, Yuri; Genet, Cyriaque; Ebbesen, Thomas W

    2016-09-15

    A thin free-standing gold membrane with complex plasmonic structures engraved on both sides is shown to perform as an ultrathin phase plate. Specifically, we demonstrate the generation of a far-field vortex beam propagating at a desired angle. The angular momentum of the beam is generated by the groove helicity, together with the geometric phase arising from a plasmonic spin-orbit interaction. The radial chirp of the back-side structure is used to modify the emission angle via a specific momentum matching condition. PMID:27628405

  13. Turbulent flows near flat plates

    NASA Astrophysics Data System (ADS)

    Kambe, R.; Imamura, T.; Doi, M.

    1980-08-01

    The method to study the effect of the plate moving in the homogeneous or isotropic turbulence is presented. The crucial point of this method is to solve the Orr-Sommerfeld like equation, which is satisfied by the kernel of the Wiener-Hermite expansion of the velocity field, under the inhomogeneous boundary condition. In the special case of constant mean flow, our method gives the same result as that of Hunt and Graham and succeeds in explaining the experimental results of Thomas and Hancock. The method is also applied to the case of nonuniform mean flow, where the shear effect comes up.

  14. Adherent protective coatings plated on magnesium-lithium alloy

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Zinc is plated on a magnesium-lithium alloy by using a modification of the standard zinc-plate immersion bath. Further protection is given the alloy by applying a light plating of copper on the zinc plating. Other metals are plated on the copper by using conventional plating baths.

  15. A Refined Shear Deformation Plate Theory

    NASA Astrophysics Data System (ADS)

    Liu, Yucheng

    2011-04-01

    An improved higher-order shear deformation theory of plates is presented in this paper. The theory is developed from the transverse shear deformation theory presented by Ambartsumian [11]. The present plate theory contains kinematics of higher-order displacement field of plates, a system of higher-order differential equilibrium equations in terms of the three generalized displacements of bending plates, and a system of boundary conditions at each edge of plate boundaries. The present shear deformation theory of plates is validated by applying it to solve torsional plates and simply supported plates. The obtained solutions using the present theory are compared with the solutions of other shear-deformation theories. A good agreement is achieved through these comparisons and the advantages of the present theory are clearly verified. The shear deformation plate theory presented here can be applied to the analysis of laminated composite plates to better predict their dynamic and static behaviors. The proposed theory should also be supplemented to the theory of finite element analysis for developing new shell elements.

  16. Petrologic implications of plate tectonics.

    PubMed

    Yoder, H S

    1971-07-30

    Petrologists can make significant contributions to the plate tectonic concept. Fixing the stability fields of the principal rock types involved will provide the limits of pressure and temperature of the various environments. Experimental determination of the partition coefficients of the trace elements will be helpful. Studies of the partial melting behavior of possible parental materials in the absence and presence of water, especially the undersaturated region, will contribute to the understanding of magma production. Experimental observations on the rheological properties of the peridotites below and just above the solidus will lead to a better evaluation of the convective mechanism. Measurement of the fundamental properties of rocks, such as the density of solids and liquids at high pressures and temperatures, would contribute to understanding the concepts of diapiric rise, magma segregation, and the low-velocity zone. Broader rock sampling of the oceanic areas of all environments will do much to define the petrologic provinces. The field petrologist specializing in the Paleozoic regions and Precambrian shields can contribute by examining those regions for old plate boundaries and devising new criteria for their recognition. PMID:17770454

  17. Petrologic implications of plate tectonics.

    PubMed

    Yoder, H S

    1971-07-30

    Petrologists can make significant contributions to the plate tectonic concept. Fixing the stability fields of the principal rock types involved will provide the limits of pressure and temperature of the various environments. Experimental determination of the partition coefficients of the trace elements will be helpful. Studies of the partial melting behavior of possible parental materials in the absence and presence of water, especially the undersaturated region, will contribute to the understanding of magma production. Experimental observations on the rheological properties of the peridotites below and just above the solidus will lead to a better evaluation of the convective mechanism. Measurement of the fundamental properties of rocks, such as the density of solids and liquids at high pressures and temperatures, would contribute to understanding the concepts of diapiric rise, magma segregation, and the low-velocity zone. Broader rock sampling of the oceanic areas of all environments will do much to define the petrologic provinces. The field petrologist specializing in the Paleozoic regions and Precambrian shields can contribute by examining those regions for old plate boundaries and devising new criteria for their recognition.

  18. Wide-Field Plate Database

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M. K.; Stavrev, K. Y.; Tsvetkova, K. P.; Semkov, E. H.; Mutatov, A. S.

    The Wide-Field Plate Database (WFPDB) and the possibilities for its application as a research tool in observational astronomy are presented. Currently the WFPDB comprises the descriptive data for 400 000 archival wide field photographic plates obtained with 77 instruments, from a total of 1 850 000 photographs stored in 269 astronomical archives all over the world since the end of last century. The WFPDB is already accessible for the astronomical community, now only in batch mode through user requests sent by e-mail. We are working on on-line interactive access to the data via INTERNET from Sofia and parallel from the Centre de Donnees Astronomiques de Strasbourg. (Initial information can be found on World Wide Web homepage URL http://www.wfpa.acad.bg.) The WFPDB may be useful in studies of a variety of astronomical objects and phenomena, andespecially for long-term investigations of variable objects and for multi-wavelength research. We have analysed the data in the WFPDB in order to derive the overall characteristics of the totality of wide-field observations, such as the sky coverage, the distributions by observation time and date, by spectral band, and by object type. We have also examined the totality of wide-field observations from point of view of their quality, availability and digitisation. The usefulness of the WFPDB is demonstrated by the results of identification and investigation of the photometrical behaviour of optical analogues of gamma-ray bursts.

  19. Effect of plate roughness on the field near RPC plates

    NASA Astrophysics Data System (ADS)

    Jash, A.; Majumdar, N.; Mukhopadhyay, S.; Chattopadhyay, S.

    2016-06-01

    The inner surfaces of the electrodes encompassing the gas volume of a Resistive Plate Chamber (RPC) have been found to exhibit asperities with, grossly, three kind of features. The desired uniform electric field within the gas volume of RPC is expected to be affected due to the presence of these asperities, which will eventually affect the final response from the detector. In this work, an attempt has been made to model the highly complex roughness of the electrode surfaces and compute its effect on the electrostatic field within RPC gas chamber. The calculations have been performed numerically using Finite Element Method (FEM) and Boundary Element Method (BEM) and the two methods have been compared in this context.

  20. Healing of fractures with freeze-dried cortical bone plates. Comparison with compression plating.

    PubMed

    Malinin, T; Latta, L L; Wagner, J L; Brown, M D

    1984-11-01

    The healing of fractures of the radius with internal fixation by stainless-steel compression plates was compared with fractures fixed with freeze-dried bone-plate allografts. Fractures fixed with metallic plates gained slightly less than half the biomechanical strength of the contralateral control bone and healed without noticeable external callus formation. Bone-plated fractures regained three-fourths of the biomechanical strength of controls and healed by forming an external callus. Bone-plate allografts were eventually incorporated in the host bone. Allograft plates were vascularized and remodeled into cancellous bone in the process of incorporation in the host bones.

  1. Axisymmetric vibration of circular plates and its analog in elliptical plates using characteristic orthogonal polynomials

    NASA Astrophysics Data System (ADS)

    Rajalingham, C.; Bhat, R. B.

    1993-02-01

    The axisymmetric vibration of circular plates and its analog in elliptic plates with clamped, simply supported and free boundary conditions are investigated using boundary characteristic orthogonal polynomials in the Rayleigh-Ritz method. Modified polar coordinates are employed to analyze the vibration of elliptical plates, with circular plates as a special case. Axisymmetric vibration of circular plates and its analog in elliptical plates with concentric nodal elipses require only one-dimensional shape functions in the Rayleigh-Ritz method. The first six natural frequencies and the parameters associated with nodal ellipses are tabulated.

  2. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1986-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  3. Excitation and Characterization of Chladni Plate Patterns

    NASA Astrophysics Data System (ADS)

    Bourke, Shannon; Behringer, Ernest

    2011-04-01

    When a thin metal plate with a small amount of sand on it is made to vibrate, aesthetically pleasing sand patterns can form along the nodal lines of the plate. These symmetric patterns are called Chladni Patterns. Students taking PHY 101 Physical Science in the Arts at Eastern Michigan University create these patterns by pulling a violin bow across the edge of a plate, or by using a mechanical oscillator to drive the center of a plate. These two methods only allow a small subset of all possible points on the plate to be excited. We designed and built an electronic device that allows its user to excite the plate at any point. We present patterns created with this electronic device and other methods, and describe ways to model the observed patterns.

  4. Membrane- and plate-type acoustic metamaterials.

    PubMed

    Huang, Tai-Yun; Shen, Chen; Jing, Yun

    2016-06-01

    Over the past decade there has been a great amount of research effort devoted to the topic of acoustic metamaterials (AMMs). The recent development of AMMs has enlightened the way of manipulating sound waves. Several potential applications such as low-frequency noise reduction, cloaking, angular filtering, subwavelength imaging, and energy tunneling have been proposed and implemented by the so-called membrane- or plate-type AMMs. This paper aims to offer a thorough overview on the recent development of membrane- or plate-type AMMs. The underlying mechanism of these types of AMMs for tuning the effective density will be examined first. Four different groups of membrane- or plate-type AMMs (membranes with masses attached, plates with masses attached, membranes or plates without masses attached, and active AMMs) will be reviewed. The opportunities, limitations, and challenges of membrane- or plate-type AMMs will be also discussed.

  5. Membrane- and plate-type acoustic metamaterials.

    PubMed

    Huang, Tai-Yun; Shen, Chen; Jing, Yun

    2016-06-01

    Over the past decade there has been a great amount of research effort devoted to the topic of acoustic metamaterials (AMMs). The recent development of AMMs has enlightened the way of manipulating sound waves. Several potential applications such as low-frequency noise reduction, cloaking, angular filtering, subwavelength imaging, and energy tunneling have been proposed and implemented by the so-called membrane- or plate-type AMMs. This paper aims to offer a thorough overview on the recent development of membrane- or plate-type AMMs. The underlying mechanism of these types of AMMs for tuning the effective density will be examined first. Four different groups of membrane- or plate-type AMMs (membranes with masses attached, plates with masses attached, membranes or plates without masses attached, and active AMMs) will be reviewed. The opportunities, limitations, and challenges of membrane- or plate-type AMMs will be also discussed. PMID:27369148

  6. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  7. Rapidly Moving Divertor Plates In A Tokamak

    SciTech Connect

    S. Zweben

    2011-05-16

    It may be possible to replace conventional actively cooled tokamak divertor plates with a set of rapidly moving, passively cooled divertor plates on rails. These plates would absorb the plasma heat flux with their thermal inertia for ~10-30 sec, and would then be removed from the vessel for processing. When outside the tokamak, these plates could be cooled, cleaned, recoated, inspected, and then returned to the vessel in an automated loop. This scheme could provide nearoptimal divertor surfaces at all times, and avoid the need to stop machine operation for repair of damaged or eroded plates. We describe various possible divertor plate designs and access geometries, and discuss an initial design for a movable and removable divertor module for NSTX-U.

  8. Overriding Plate Deformation During Subduction Evolution

    NASA Astrophysics Data System (ADS)

    Davies, J. H.; Garel, F.; Davies, R.; Goes, S. D. B.

    2015-12-01

    Subduction dynamics has been widely studied in free subduction models, which document the important control of the downgoing plate. However, various models have shown how the overriding plate can influence subduction dynamics through its thermal structure, thickness and coupling. Using the code Fluidity we investigate overriding plate deformation in a 2-D thermo-mechanical model of the two-plate subduction system. We use Fluidity's adaptive mesh and free-surface formulation. The model includes a composite temperature- and stress-dependent rheology, and plates are decoupled by a weak layer, which allows for free trench motion. We focus on the evolution of the topography and state of stress in the overriding plate during the different phases of the subduction process: early stages of subduction, free-fall sinking in the upper mantle and interaction of the slab with the high-viscosity lower mantle.

  9. Coupling between plate vibration and acoustic radiation

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Maestrello, Lucio; Bayliss, Alvin

    1992-01-01

    A detailed numerical investigation of the coupling between the vibration of a flexible plate and the acoustic radiation is performed. The nonlinear Euler equations are used to describe the acoustic fluid while the nonlinear plate equation is used to describe the plate vibration. Linear, nonlinear, and quasi-periodic or chaotic vibrations and the resultant acoustic radiation are analyzed. We find that for the linear plate response, acoustic coupling is negligible. However, for the nonlinear and chaotic responses, acoustic coupling has a significant effect on the vibration level as the loading increases. The radiated pressure from a plate undergoing nonlinear or chaotic vibrations is found to propagate nonlinearly into the far-field. However, the nonlinearity due to wave propagation is much weaker than that due to the plate vibrations. As the acoustic wave propagates into the far-field, the relative difference in level between the fundamental and its harmonics and subharmonics decreases with distance.

  10. Anisotropic magnetocapacitance in ferromagnetic-plate capacitors

    NASA Astrophysics Data System (ADS)

    Haigh, J. A.; Ciccarelli, C.; Betz, A. C.; Irvine, A.; Novák, V.; Jungwirth, T.; Wunderlich, J.

    2015-04-01

    The capacitance of a parallel-plate capacitor can depend on the applied magnetic field. Previous studies have identified capacitance changes induced via classical Lorentz force or spin-dependent Zeeman effects. Here we measure a magnetization direction-dependent capacitance in parallel-plate capacitors where one plate is a ferromagnetic semiconductor, gallium manganese arsenide. This anisotropic magnetocapacitance is due to the anisotropy in the density of states dependent on the magnetization through the strong spin-orbit interaction.

  11. High performance flat plate solar collector

    NASA Technical Reports Server (NTRS)

    Lansing, F. L.; Reynolds, R.

    1976-01-01

    The potential use of porous construction is presented to achieve efficient heat removal from a power producing solid and is applied to solar air heaters. Analytical solutions are given for the temperature distribution within a gas-cooled porous flat plate having its surface exposed to the sun's energy. The extracted thermal energy is calculated for two different types of plate transparency. Results show the great improvement in performance obtained with porous flat plate collectors as compared with analogous nonporous types.

  12. High speed thin plate fatigue crack monitor

    NASA Technical Reports Server (NTRS)

    Wincheski, Buzz A. (Inventor); Heyman, Joseph S. (Inventor); Namkung, Min (Inventor); Fulton, James P. (Inventor)

    1996-01-01

    A device and method are provided which non-destructively detect crack length and crack geometry in thin metallic plates. A non-contacting vibration apparatus produces resonant vibrations without introducing extraneous noise. Resulting resonant vibration shifts in cracked plates are correlated to known crack length in plates with similar resonant vibration shifts. In addition, acoustic emissions of cracks at resonance frequencies are correlated to acoustic emissions from known crack geometries.

  13. Real time monitoring of electroless nickel plating

    NASA Astrophysics Data System (ADS)

    Rains, Aaron E.; Kline, Ronald A.

    2013-01-01

    This work deals with the design and manufacturing of the heat and chemical resistant transducer case required for on-line immersion testing, experimental design, data acquisition and signal processing. Results are presented for several depositions with an accuracy of two ten-thousandths of an inch in coating thickness obtained. Monitoring the deposition rate of Electroless Nickel (EN) plating in-situ will provide measurement of the accurate dimensions of the component being plated, in real time. EN is used as for corrosion and wear protection for automotive an - Electroless Nickel (EN) plating is commonly used for corrosion and wear protection for automotive and aerospace components. It plates evenly and symmetrically, theoretically allowing the part to be plated to its final dimension. Currently the standard approach to monitoring the thickness of the deposited nickel is to remove the component from the plating bath and physically measure the part. This can lead to plating problems such as pitting, non-adhesion of the deposit and contamination of the plating solution. The goal of this research effort is to demonstrate that plating thickness can be rapidly and accurately measured using ultrasonic testing. Here a special housing is designed to allow immersion of the ultrasonic transducers directly into the plating bath. An FFT based signal processing algorithm was developed to resolve closely spaced echoes for precise thickness determination. The technique in this research effort was found to be capable of measuring plating thicknesses to within 0.0002 inches. It is expected that this approach will lead to cost savings in many EN plating operations.

  14. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon; Larcher, Steven; Henderson, Gena; Tran, Donald

    2011-01-01

    Over the years there have been several occurrences of damage to Space Shuttle Orbiter cold plates during removal and replacement of avionics boxes. Thus a process improvement team was put together to determine ways to prevent these kinds of damage. From this effort there were many solutions including, protective covers, training, and improved operations instructions. The focus of this paper is to explain the cold plate damage problem and the corrective actions for preventing future damage to aerospace avionics cold plate designs.

  15. Reliability assessment of different plate theories for elastic wave propagation analysis in functionally graded plates.

    PubMed

    Mehrkash, Milad; Azhari, Mojtaba; Mirdamadi, Hamid Reza

    2014-01-01

    The importance of elastic wave propagation problem in plates arises from the application of ultrasonic elastic waves in non-destructive evaluation of plate-like structures. However, precise study and analysis of acoustic guided waves especially in non-homogeneous waveguides such as functionally graded plates are so complicated that exact elastodynamic methods are rarely employed in practical applications. Thus, the simple approximate plate theories have attracted much interest for the calculation of wave fields in FGM plates. Therefore, in the current research, the classical plate theory (CPT), first-order shear deformation theory (FSDT) and third-order shear deformation theory (TSDT) are used to obtain the transient responses of flexural waves in FGM plates subjected to transverse impulsive loadings. Moreover, comparing the results with those based on a well recognized hybrid numerical method (HNM), we examine the accuracy of the plate theories for several plates of various thicknesses under excitations of different frequencies. The material properties of the plate are assumed to vary across the plate thickness according to a simple power-law distribution in terms of volume fractions of constituents. In all analyses, spatial Fourier transform together with modal analysis are applied to compute displacement responses of the plates. A comparison of the results demonstrates the reliability ranges of the approximate plate theories for elastic wave propagation analysis in FGM plates. Furthermore, based on various examples, it is shown that whenever the plate theories are used within the appropriate ranges of plate thickness and frequency content, solution process in wave number-time domain based on modal analysis approach is not only sufficient but also efficient for finding the transient waveforms in FGM plates.

  16. An arbitrarily shaped inclusion with uniform eigencurvatures in an infinite plate, semi-infinite plate, two bonded semi-infinite plates or a circular plate

    NASA Astrophysics Data System (ADS)

    Wang, Xu; Zhou, Kun

    2015-04-01

    Within the framework of the Kirchhoff-Love isotropic and homogeneous plate theory, we obtain, in a unified manner, the analytic solutions to the Eshelby's problem of an inclusion of arbitrary shape with uniform eigencurvatures in an infinite plate, a semi-infinite plate, one of two bonded semi-infinite plates or a circular plate by means of conformal mapping and analytical continuation. The edge of the semi-infinite plate can be rigidly clamped, free or simply supported, while that of the circular plate can be rigidly clamped, free or perfectly bonded to the surrounding infinite plate. Several examples of practical and theoretical interests are presented to demonstrate the general method. In particular, the elementary expressions of the internal elastic fields of bending moments and deflections within an ( n + 1)-fold rotational symmetric inclusion described by a five-term mapping function, a symmetric airfoil cusp inclusion, a symmetric lip cusp inclusion and an inclusion described by a rational mapping function in an infinite plate are derived.

  17. Bipolar plates for PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Middelman, E.; Kout, W.; Vogelaar, B.; Lenssen, J.; de Waal, E.

    The bipolar plates are in weight and volume the major part of the PEM fuel cell stack, and are also a significant contributor to the stack costs. The bipolar plate is therefore a key component if power density has to increase and costs must come down. Three cell plate technologies are expected to reach targeted cost price levels, all having specific advantages and drawbacks. NedStack has developed a conductive composite materials and a production process for fuel cell plates (bipolar and mono-polar). The material has a high electric and thermal conductivity, and can be processed into bipolar plates by a proprietary molding process. Process cycle time has been reduced to less than 10 s, making the material and process suitable for economical mass production. Other development work to increase material efficiency resulted in thin bipolar plates with integrated cooling channels, and integrated seals, and in two-component bipolar plates. Total thickness of the bipolar plates is now less than 3 mm, and will be reduced to 2 mm in the near future. With these thin integrated plates it is possible to increase power density up to 2 kW/l and 2 kW/kg, while at the same time reducing cost by integrating other functions and less material use.

  18. Wave propagation in metamaterial lattice sandwich plates

    NASA Astrophysics Data System (ADS)

    Fang, Xin; Wen, Jihong; Yin, Jianfei; Yu, Dianlong

    2016-04-01

    This paper designed a special acoustic metamaterial 3D Kagome lattice sandwich plate. Dispersion properties and vibration responses of both traditional plate and metamaterial plate are investigated based on FEA methods. The traditional plate does not have low-frequency complete bandgaps, but the metamaterial plate has low-frequency complete bandgap (at 620Hz) coming from the symmetrical local cantilever resonators. The bandgap frequency is approximate to the first-order natural frequency of the oscillator. Complex wave modes are analyzed. The dispersion curves of longitudinal waves exist in the flexural bandgap. The dispersion properties demonstrate the metamaterial design is advantageous to suppress the low-frequency flexural wave propagation in lattice sandwich plate. The flexural vibrations near the bandgap are also suppressed efficiently. The longitudinal excitation stimulates mainly longitudinal waves and lots of low-frequency flexural vibration modes are avoided. Furthermore, the free edge effects in metamaterial plate provide new method for damping optimizations. The influences of damping on vibrations of the metamaterial sandwich plate are studied. Damping has global influence on the wave propagation; stronger damping will induce more vibration attenuation. The results enlighten us damping and metamaterial design approaches can be unite in the sandwich plates to suppress the wave propagations.

  19. Plate electrode arrangement for an electrostatic precipitator

    SciTech Connect

    Wooldridge, J.E.

    1982-06-01

    An electrode plate arrangement for an electrostatic precipitator including a plurality of essentially identical plate assemblies secured in an opposing fashion to the opposite sides of a gridlike mounting frame extending across the interior of the precipitator. The plate assemblies on the upstream side of the frame include an ionizing zone for the dirty gas stream which feeds into serially aligned collecting zones in the opposing assemblies which in turn feed into a deionizing zone in the plate assemblies on the downstream side of the frame.

  20. Plate Tectonics: A Paradigm under Threat.

    ERIC Educational Resources Information Center

    Pratt, David

    2000-01-01

    Discusses the challenges confronting plate tectonics. Presents evidence that contradicts continental drift, seafloor spreading, and subduction. Reviews problems posed by vertical tectonic movements. (Contains 242 references.) (DDR)

  1. Fuel cell cooler-humidifier plate

    DOEpatents

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  2. Limit cycle oscillation of a fluttering plate

    NASA Astrophysics Data System (ADS)

    Ye, Wei-Liang

    1992-09-01

    The limit cycle oscillation for a cantilever plate in a uniform flow stream is investigated. Von Karman's theory for a large deflection plate and quasi-steady aerodynamic theory are assumed. The equations for computing the nonlinear oscillation of a fluttering cantilever plate are derived by means of Rayleigh-Ritz approach. Lagrange's equations and a set of mode function expansions are employed. Time marching simulation is used to determine the limit cycle oscillation and fluttering boundary. The results indicate that the modal expansion is of convergence. The length-to-width ratio of a plate has a great effect on the flutter amplitude of the limit cycle.

  3. MACMA: a Virtual Lab for Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Grigne, C.; Combes, M.; Tisseau, C.

    2013-12-01

    MACMA (Multi-Agent Convective MAntle) is a tool developed to simulate evolutive plate tectonics and mantle convection in a 2-D cylindrical geometry (Combes et al., 2012). The model relies mainly on a force balance to compute the velocity of each plate, and on empirical rules to determine how plate boundaries move and evolve. It includes first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. The MACMA interface was designed to be user-friendly and a simple use of the simulator can be achieved without any prerequisite knowledge in fluid dynamics, mantle rheology, nor in numerical methods. As a preliminary study, the simulator was used by a few students from bachelor's degree to master's degree levels. An initial configuration for plate tectonics has to be created before starting a simulation: the number and types of plate boundaries (ridge, subduction, passive margins) has to be defined and seafloor ages must be given. A simple but interesting exercise consists in letting students build such an initial configuration: they must analyze a map of tectonic plates, choose a 2-D section and examine carefully a map of seafloor ages. Students mentioned that the exercise made them realize that the 3-D spherical structure of plate tectonics does not translate directly in a simple 2-D section, as opposed to what is usually shown in books. Physical parameters: e.g. mantle viscosity, number of layers to consider in the mantle (upper and lower mantle, possible asthenosphere), initial time and mantle temperature, have to be chosen, and students can use this virtual lab to see how different scenarios emerge when parameters are varied. Very importantly, the direct visualization of the mobility of plate

  4. Tunable surface plasmon wave plates.

    PubMed

    Djalalian-Assl, Amir; Cadusch, Jasper J; Balaur, Eugeniu; Aramesh, Morteza

    2016-07-01

    The highest resonant transmission through an array of holes perforated in metallic screens occurs when the dielectric constant of the substrate, the superstrate, and the hole are the same. Changes in the refractive index of the homogenous environment also produce the largest shift in resonances per refractive index unit. In this Letter, we first propose and apply a technique in realization of a freestanding bi-periodic array of holes perforated in a silver film. We then show both numerically and experimentally that shifts in (1,0) and (0,1) modes in response to changes in the refractive index of the surrounding dielectric provide a mechanism for realization of a miniaturized tunable quarter-wave plate that operates in an extraordinary optical transmission mode with a high throughput and a near unity state of circularly polarized light. PMID:27367123

  5. Composition of the continental plates

    USGS Publications Warehouse

    Gilluly, J.

    1954-01-01

    The structures of continental plates and of oceanic basins suggested by several seismologists are utilized to estimate the relative volumes of sial and sima in the earth's crust. It seems that sial of the composition of the average igneous rock constitutes fully 26% and perhaps as much as 43% of the total crust. This ratio is far higher than seems likely if the sial had been entirely derived through fractional crystallization of a basaltic magma. The relative paucity of intermediate rocks as compared with granite and gabbro in the crust points in the same direction. The tentative conclusion is reached that the sial owes a large part of its volume to some process other than fractional crystallization of basalt-possibly to the emanation of low-melting constituents such as water, silica, potassa, soda, and alumina directly from the mantle to the crust. ?? 1954 Springer-Verlag.

  6. Waste minimization in chrome plating

    SciTech Connect

    Scheuer, J.; Walter, K.; Nastasi, M.

    1996-09-01

    This is the final report of a one year laboratory directed research and development project at the Los Alamos National Laboratory (LANL). Traditional wet chemical electroplating techniques utilize toxic materials and pose environmental hazards in the disposal of primary baths and waste waters. Pollutants include metals and nonmetals, such as oil, grease, phosphates, and toxic and organic compounds. This project is focused on development of plasma source ion implantation (PSII), a novel and cost-effective surface modification technique, to minimize and ultimately eliminate waste generated in chrome plating. We are collaborating with and industrial partner to design material systems, utilize the PSII processes in existing Los Alamos experimental facilities, and analyze both material and performance characteristics.

  7. Isopachic contouring of opaque plates

    NASA Technical Reports Server (NTRS)

    Post, D.; Asundi, A.; Czarnek, R.

    1984-01-01

    Contour maps of change of thickness of opaque plates subjected to external loads are obtained using holographic interferometry in conjunction with the moire effect. A simple holographic-interferometry arrangement is used first to obtain contour maps of the out-of-plane displacements of the two sides of the object. Carrier patterns of equal magnitude but opposite signs are added to these contours. Superposition of the reconstructed holograms of the two sides produces a pattern of additive-moire fringes, which are contours of change of thickness. Effects of midplane warpage of the loaded specimen are cancelled. Sensitivity is lambda/2 per fringe order, contrast of the isopachic-fringe pattern is excellent, and the process is compatible with a mechanical-testing-machine environment.

  8. Inter- and intra-plate deformation at North American plate boundaries

    NASA Technical Reports Server (NTRS)

    Beavan, John

    1986-01-01

    Alaska tectonics and earthquake hazard studies; Southern California tectonics (block rotation); spreading near the Salton Trough; California plate motion (fault zone kinematics); and Caribbean plate motion investigations are examined.

  9. A Treatise on Equivalent-Plate Stiffnesses for Stiffened Laminated-Composite Plates and Plate-Like Lattices

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    2011-01-01

    A survey of studies conducted since 1914 on the use of equivalent-plate stiffnesses in modeling the overall, stiffness-critical response of stiffened plates and shells is presented. Two detailed, comprehensive derivations of first-approximation equivalent-plate stiffnesses are also presented that are based on the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. Equivalent-plate stiffness expressions, and a corresponding symbolic manipulation computer program, are also presented for several different stiffener configurations. These expressions are very general and exhibit the full range of anisotropies permitted by the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. The expressions presented in the present study were also compared with available, previously published results. For the most part, the previously published results are for special cases of the general expressions presented herein and are almost in complete agreement. Analysis is also presented that extends the use of the equivalent-plate stiffness expressions to sandwich plates.

  10. Simulation of Evolutive Plate Tectonics: the Size of Plates Depends on Mantle Temperature

    NASA Astrophysics Data System (ADS)

    Grigne, C.; Combes, M.

    2013-12-01

    We use a dynamic model of plate tectonics based on a multiagent approach, in a 2D cylindrical geometry (Combes et al., 2012), to study how evolutive plate tectonics affect the long term thermal state of the mantle, and in return, to analyze the relationship between the mantle mean temperature and the geometry of plate tectonics. Our model accounts for first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. We show that when processes for plate boundary creation (subduction initiation and ridge creation) are relying on a brittle criterion, namely when a fixed yield strength has to be reached, the average size of plates adapts to the mantle thermal state: longer plates are obtained for a hotter mantle, which implies a maximum seafloor age that remains fairly high throughout Earth's thermal history and limits mantle heat loss. This is consistent with petrological and geochemical constraints on Earth's cooling history. Important fluctuations in the mantle heat flux and velocities of plates are obtained on a timescale of a few hundred Myr, but on the long term, the relationship between the average wavelength of plate tectonics and mantle temperature can be explained by a simple scaling law. Recent compilations of geological records infer that passive margins had longer lifespans in the past (e.g. Bradley 2008; 2011), which has been linked to 'sluggish' plate tectonics and slow plates in the Precambrian (Korenaga, 2006). Our simulations outputs include lifespans of tectonic entities such as passive margins, as well as statistical data about events of plates reorganizations. We obtain faster plates in the past than at present day, but counterintuitively we also observe a low episodicity of tectonic

  11. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  12. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  13. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  14. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  15. Pressure-Letdown Plates for Coal Gasifiers

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1985-01-01

    Variation of pseudoporous plates used with coal gasifiers in pressure letdown stage of processing minimize clogging. Rotating plates containing variable gap annuli continually change flow path to enable erosionless reduction of gas pressure. Particles that otherwise clog porous plugs pass through gaps.

  16. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  17. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  18. Plate Tectonic Cycle. K-6 Science Curriculum.

    ERIC Educational Resources Information Center

    Blueford, J. R.; And Others

    Plate Tectonics Cycle is one of the units of a K-6 unified science curriculum program. The unit consists of four organizing sub-themes: (1) volcanoes (covering formation, distribution, and major volcanic groups); (2) earthquakes (with investigations on wave movements, seismograms and sub-suface earth currents); (3) plate tectonics (providing maps…

  19. Improved nickel plating of Inconel X-750

    NASA Technical Reports Server (NTRS)

    Farmer, M. E.; Feeney, J. E.; Kuster, C. A.

    1969-01-01

    Electroplating technique with acid pickling provides a method of applying nickel plating on Inconel X-750 tubing to serve as a wetting agent during brazing. Low-stress nickel-plating bath contains no organic wetting agents that cause the nickel to blister at high temperatures.

  20. Spiral plate method for bacterial determination.

    PubMed

    Gilchrist, J E; Campbell, J E; Donnelly, C B; Peeler, J T; Delaney, J M

    1973-02-01

    A method is described for determining the number of bacteria in a solution by the use of a machine which deposits a known volume of sample on a rotating agar plate in an ever decreasing amount in the form of an Archimedes spiral. After the sample is incubated, different colony densities are apparent on the surface of the plate. A modified counting grid is described which relates area of the plate of volume of sample. By counting an appropriate area of the plate, the number of bacteria in the sample is estimated. This method was compared to the pour plate procedure with the use of pure and mixed cultures in water and milk. The results did not demonstrate a significant difference in variance between duplicates at the alpha = 0.01 level when concentrations of 600 to 12 x 10(5) bacteria per ml were used, but the spiral plate method gave counts that were higher than counts obtained by the pour plate method. The time and materials required for this method are substantially less than those required for the conventional aerobic pour plate procedure.

  1. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  2. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  3. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  4. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  5. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  6. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  7. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  8. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  9. Computing relative plate velocities: a primer

    SciTech Connect

    Bevis, M.

    1987-08-01

    Standard models of present-day plate motions are framed in terms of rates and poles of rotation, in accordance with the well-known theorem due to Euler. This article shows how computation of relative plate velocities from such models can be viewed as a simple problem in spherical trigonometry. A FORTRAN subroutine is provided to perform the necessary computations.

  10. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away...

  11. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away...

  12. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away...

  13. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away...

  14. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to the boiler backhead in the cab. If boiler backhead is lagged, the lagging and jacket shall be cut away...

  15. Layered Plating Specimens For Mechanical Tests

    NASA Technical Reports Server (NTRS)

    Thompson, Linda B.; Flowers, Cecil E.

    1991-01-01

    Layered specimens readily made in standard sizes for tensile and other tests of mechanical properties. Standard specimen of metal ordinarily difficult to plate to standard grip thickness or diameter made by augmentation with easier-to-plate material followed by machining to standard size and shape.

  16. Is There Really A North American Plate?

    NASA Astrophysics Data System (ADS)

    Krill, A.

    2011-12-01

    Lithospheric plates are typically identified from earthquake epicenters and evidence such as GPS movements. But no evidence indicates a plate boundary between the North American and South American Plates. Some plate maps show them separated by a transform boundary, but it is only a fracture zone. Other maps show an "undefined plate boundary" or put no boundary between these two plates (check Google images). Early plate maps showed a single large American Plate, quite narrow east of the Caribbean Plate (Le Pichon 1968, Morgan 1968). The North and South American Plates became established by the leading textbook Earth (Press & Siever 1974). On their map, from a Scientific American article by John Dewey (1972), these new plates were separated by an "uncertain plate boundary." The reasons for postulating a North American Plate were probably more psychological than geological. Each of the other continents of the world had its own plate, and North American geologists naturally wanted theirs. Similarly, European geographers used to view Europe as its own continent. A single large plate should again be hypothesized. But the term American Plate would now be ambiguous ("Which plate, North or South?") Perhaps future textbook authors could call it the "Two-American Plate." Textbook authors ultimately decide such global-tectonic matters. I became aware of textbook authors' opinions and influence from my research into the history of Alfred Wegener's continental drift (see Fixists vs. Mobilists by Krill 2011). Leading textbook author Charles Schuchert realized that continental drift would abolish his cherished paleogeographic models of large east-west continents (Eria, Gondwana) and small oceans (Poseiden, Nereis). He and his junior coauthors conspired to keep drift evidence out of their textbooks, from the 1934-editions until the 1969-editions (Physical Geology by Longwell et al. 1969, Historical Geology by Dunbar & Waage 1969). Their textbooks ruled in America. Textbooks

  17. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  18. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  19. Cycloid kinematics of relative plate motion

    SciTech Connect

    Cronin, V.S.

    1987-11-01

    The trajectory of a point on one plate as observed from another plate is generally a complex curve and not a small circle around a single axis of relative motion, as is commonly assumed. The shape of the relative-motion path is given the general name spherical cycloid because of its morphological similarity to cycloid planetary trajectories described by early astronomers. The cycloid relative-motion model predicts that the following phenomena occur during finite displacements: (1) the relative velocity and the curvature of the trajectory of a point on one plate relative to another plate varies systematically; (2) plates wobble relative to one another; and (3) the angle of convergence and/or divergence varies systematically along the length of any given transform fault. The small-circle relative-motion model, whereby transform faults have been considered lines of pure slip along which crust is conserved, is not generally valid for finite relative displacements.

  20. Volcanism in response to plate flexure.

    PubMed

    Hirano, Naoto; Takahashi, Eiichi; Yamamoto, Junji; Abe, Natsue; Ingle, Stephanie P; Kaneoka, Ichiro; Hirata, Takafumi; Kimura, Jun-Ichi; Ishii, Teruaki; Ogawa, Yujiro; Machida, Shiki; Suyehiro, Kiyoshi

    2006-09-01

    Volcanism on Earth is known to occur in three tectonic settings: divergent plate boundaries (such as mid-ocean ridges), convergent plate boundaries (such as island arcs), and hot spots. We report volcanism on the 135 million-year-old Pacific Plate not belonging to any of these categories. Small alkalic volcanoes form from small percent melts and originate in the asthenosphere, as implied by their trace element geochemistry and noble gas isotopic compositions. We propose that these small volcanoes erupt along lithospheric fractures in response to plate flexure during subduction. Minor extents of asthenospheric melting and the volcanoes' tectonic alignment and age progression in the direction opposite to that of plate motion provide evidence for the presence of a small percent melt in the asthenosphere. PMID:16873612

  1. Pyramidal approach to license plate segmentation

    NASA Astrophysics Data System (ADS)

    Postolache, Alexandru; Trecat, Jacques C.

    1996-07-01

    Car identification is a goal in traffic control, transport planning, travel time measurement, managing parking lot traffic and so on. Most car identification algorithms contain a standalone plate segmentation process followed by a plate contents reading. A pyramidal algorithm for license plate segmentation, looking for textured regions, has been developed on a PC based system running Unix. It can be used directly in applications not requiring real time. When input images are relatively small, real-time performance is in fact accomplished by the algorithm. When using large images, porting the algorithm to special digital signal processors can easily lead to preserving real-time performance. Experimental results, for stationary and moving cars in outdoor scenes, showed high accuracy and high scores in detecting the plate. The algorithm also deals with cases where many character strings are present in the image, and not only the one corresponding to the plate. This is done by the means of a constrained texture regions classification.

  2. Tectonic Evolution of the Jurassic Pacific Plate

    NASA Astrophysics Data System (ADS)

    Nakanishi, M.; Ishihara, T.

    2015-12-01

    We present the tectonic evolution of the Jurassic Pacific plate based on magnetic anomly lineations and abyssal hills. The Pacific plate is the largest oceanic plate on Earth. It was born as a microplate aroud the Izanagi-Farallon-Phoenix triple junction about 192 Ma, Early Jurassic [Nakanishi et al., 1992]. The size of the Pacific plate at 190 Ma was nearly half that of the present Easter or Juan Fernandez microplates in the East Pacific Rise [Martinez et at, 1991; Larson et al., 1992]. The plate boundary surrounding the Pacific plate from Early Jurassic to Early Cretaceous involved the four triple junctions among Pacific, Izanagi, Farallon, and Phoenix plates. The major tectonic events as the formation of oceanic plateaus and microplates during the period occurred in the vicinity of the triple junctions [e.g., Nakanishi and Winterer, 1998; Nakanishi et al., 1999], implying that the study of the triple junctions is indispensable for understanding the tectonic evolution of the Pacific plate. Previous studies indicate instability of the configuration of the triple junctions from Late Jurassic to Early Cretaceous (155-125 Ma). On the other hand, the age of the birth of the Pacific plate was determined assuming that all triple junctions had kept their configurations for about 30 m.y. [Nakanishi et al., 1992] because of insufficient information of the tectonic history of the Pacific plate before Late Jurassic.Increase in the bathymetric and geomagnetic data over the past two decades enables us to reveal the tectonic evolution of the Pacific-Izanagi-Farallon triple junction before Late Jurassic. Our detailed identication of magnetic anomaly lineations exposes magnetic bights before anomaly M25. We found the curved abyssal hills originated near the triple junction, which trend is parallel to magnetic anomaly lineations. These results imply that the configuration of the Pacific-Izanagi-Farallon triple junction had been RRR before Late Jurassic.

  3. Parallel Plate System for Collecting Data Used to Determine Viscosity

    NASA Technical Reports Server (NTRS)

    Kaukler, William (Inventor); Ethridge, Edwin C. (Inventor)

    2013-01-01

    A parallel-plate system collects data used to determine viscosity. A first plate is coupled to a translator so that the first plate can be moved along a first direction. A second plate has a pendulum device coupled thereto such that the second plate is suspended above and parallel to the first plate. The pendulum device constrains movement of the second plate to a second direction that is aligned with the first direction and is substantially parallel thereto. A force measuring device is coupled to the second plate for measuring force along the second direction caused by movement of the second plate.

  4. Investigation on mechanical properties of contemporary metallic bone plates: towards the development of composite bone plates.

    PubMed

    Hoque, M E; Zainal, N H; Syarif, J

    2008-07-01

    This study aims at investigating the mechanical properties of the contemporary metallic bone plates determining the effect of their length, width and thickness on the properties and compares with the composite bone plates. Three-points bending test was performed over the stainless steel plates of different length, width and thickness. The test results showed that different plates had different mechanical properties. However, the properties are still much higher than that of particular bones intended to be treated. Therefore, the reported findings strongly encourage developing composite bone plates with biocompatible polymers/fibers that would have modulated properties according to the requirements.

  5. Vibration of plates using plate characteristic functions obtained by reduction of partial differential equation

    NASA Astrophysics Data System (ADS)

    Bhat, R. B.; Mundkur, G.

    1993-02-01

    Vibration of rectangular plates is studied using a set of plate characteristic functions generated by reduction of the plate partial differential equation, and exactly solving the resulting ordinary differential equation. The plate characteristic functions are used as deflection shape functions in the Rayleigh-Ritz method to obtain the natural frequencies. Because the solution is exact in one direction, the results fall in between the exact values and those obtained with the straight forward Rayleigh-Ritz method, where the complete deflection shape is assumed initially. Results are provided for rectangular plates with combinations of clamped, simply supported and free edge conditions.

  6. The jubilee of plate tectonics

    NASA Astrophysics Data System (ADS)

    Glen, William; Frankel, Henry

    What should one expect at a birthday gathering for an idea that suffered disdain from birth, but was later transformed overnight into the ruling global theory of the Earth sciences? Tom Hilde and Richard Carlson (Texas A&M University, College Station, Tex.), under the auspices of the Texas A&M Geodynamics Research Institute, with the cooperation of the National Aeronautics and Space Administration (NASA) , the Inter-Union Commission on the Lithosphere, and the U.S. Geodynamics Committee, convened an unprecedented gathering of the makers of Earth science's modern revolution and a large number of their foremost disciples at Texas A&M April 22- 24 , 1987.Those who missed the show will have to read for weeks to learn of the panoply of profound new developments across the broad front of research bearing on plate tectonics, but those with an interest in their own intellectual genealogy will not be able to recapture the sense of historic moment that pervaded Rudder Tower Conference Center as many of the old revolutionaries opened windows on the past. Of the 20 key participants or originators who were invited to speak, all but four sent abstracts. Pleased and surprised by this strong response, the convenors found themselves in the rather difficult position of having to limit the number of talks by nonoriginators to 20. The unique assembly also provided the first opportunity to video interviews with more than a dozen of the originators.

  7. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  8. Collaborative study comparing the spiral plate and aerobic plate count methods.

    PubMed

    Gilchrist, J E; Donnelly, C B; Peeler, J T; Campbell, J E

    1977-07-01

    The spiral plate count method is a semiautomated plating technique that greatly reduces manpower and material costs normally associated with the pour plating technique. In this collaborative study, 8 laboratories compared the spiral and pour plating techniques, using 4 samples each of 3 products: frozen pumpkin pie, frozen chicken pot pie, and shampoo. The results show that 10 of the 12 comparisons of means of the pour and spiral methods were not significantly different; 2 values were significant at alpha = 0.01. Overall, the components of variance were less than that of the current milk standard, and the replicate per cent coefficient of variation was satisfactory. This study indicates that the spiral plate method is an acceptable alternative to the pour plate method; the spiral plate method has been adopted as official first action.

  9. On the Origin of Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Bercovici, D.

    2014-12-01

    The emergence of plate tectonics was Earth's defining moment. How and when platetectonics started is shrouded in mystery because of the paucity of observations in theArchean as well the challenge of understanding how plates are generated. The damage theoryof lithospheric weakening by grain-reduction provides a physical framework for plategeneration. This model builds on grain-scale processes to elucidate planetary-scaletectonics, and is consistent with lab and field observations of polycrystalline rocks andlithospheric shear zones. The grain-damage model accounts for the evolution of damage andhealing (by grain growth) at various planetary conditions, hence predicts plate boundaryformation and longevity, and how they depend on surface environment. For example, the onset of prototectonics is predicted to require clement conditions tokeep healing from erasing weak zones; conversely, cool conditions possibly requiredtectonics to draw down primordial CO2. Thus whether tectonics preceded a cool climate (andwater) or vice versa is immaterial as they likely needed each other or neither wouldexist. Sparse evidence that prototectonics co-initiated with liquid water hints at thelink between tectonics, water and surface conditions. The establishment of wide-spread plate tectonics started between >4Ga and 2.7Ga, and mayhave taken over a billion years to develop. Under Earth-like conditions, combininggrain-damage with intermittent Archean protosubduction produces persistent weak zones thataccumulate to yield well developed plates within 1Gyrs. In contrast, Venus' hottersurface conditions promotes healing and prohibits weak zone accumulation, which explainswhy plate tectonics failed to spread on our sister planet. Damage and weak-zone inheritance may also influence plate evolution and reorganization inthe modern era. Changes in plate direction, such as reflected in the Emperor-Hawaiianbend, leave weak zones misaligned with plate motion, causing oblique plate boundaries

  10. Reducing chromium losses from a chromium plating bath. 1987 summer intern report. Project conducted at New Dimension Plating, Hutchinson, Minnesota

    SciTech Connect

    Achman, D.

    1987-12-31

    The company employs about forty people and operates for one or two eight hour shifts with an average of 315 racks of chrome plating per eight hour day. They plate a variety of metals including copper, nickel, gold, brass and chromium. Chromium is the major metal plated and is usually the last step in plating cycle. Most parts are copper plated and then nickel plated in preparation for chrome plating. The main difference between New Dimension Plating and other plating shops is the variety of parts plated. As New Dimension Plating is a job shop, a wide range of parts such as motorcycle accessories, stove parts, and custom items are metal finished. The plating lines are manual, meaning employees dip the racks into the tanks by hand. This fact along with the fact that parts vary greatly in size and shape accounts for the significant drag-out on the chromium plating line.

  11. Relations between plate kinematics, slab geometry and overriding plate deformation in subduction zones: insights from statistical observations and laboratory modelling

    NASA Astrophysics Data System (ADS)

    Heuret, A.; Funiciello, F.; Faccenna, C.; Lallemand, S.

    2005-12-01

    3-D laboratory models have been performed in order to investigate the way plates kinematics (subducting and overriding plate absolute motions and the resulting plate convergence rate) influences the geometry of the slab and the overriding plate deformation in subduction zones. In the experiments a viscous plate of silicone (subducting plate) is pushed beneath another plate, which is itself pushed toward or pulled away from the trench (overriding plate), and sinks into a viscous layer of glucose syrup (upper mantle). The subducting and overriding plate velocities explored the variability field of natural subduction plates kinematics. The overriding plate motion exerts a primary role in the control of slab geometries and overriding plate deformation rates. The experiments have revealed two different subduction behaviours: (Style I) the overriding plate moves toward the trench and shortens at high rates, the slab is flat and deflected when reaching the bottom of the box in a forward direction; (Style II) the overriding plates moves away from the trench and shortens at low rates the slab is steep and deflected on the box bottom in a backward direction. To a lesser extent, increasing subducting plate motion is associated to increasing slab dips and overriding plate shortening. Slab geometry and overriding plate deformation are less sensitive to the overall plate convergence rate. These laboratory models behaviours are consistent with statistical analysis performed on natural subduction zones, and enlighten the first order control exerted by the overriding plate absolute motion, on the geometry adopted by the slab and the way the overriding plate deforms.

  12. Global Plate Driving Forces at 50Ma

    NASA Astrophysics Data System (ADS)

    Butterworth, N. P.; Quevedo, L. E.; Müller, R. D.

    2011-12-01

    We apply a novel workflow utilising the BEM-Earth geodynamic software to analyse the global coupled plate-mantle dynamics at 50 Ma. A subduction history model based on kinematic data going as far back as 80 Ma was developed using the GPlates software. Advection of the plates into the mantle takes into account the absolute plate motions and lithospheric thickness derived from its age to produce an estimated density heterogeneity initial model condition in the upper mantle. The resulting global model consists of regions of a mantle viscosity and density structure that is post-processed to ensure smooth non-overlapping 3D surfaces. BEM-Earth is then free to evolve the model toward the 50 Ma solution. The evolution of the model is driven by self-consistent buoyancy driven mantle dynamics. We use the model velocity output to quantify changes in forces driving the plates before and after 50 Ma. We analyse the rapid change in plate motion of India, Africa and plates in the Pacific Ocean basin by considering slab-pull, ridge-push and mantle drag/suction forces that naturally result from such top-down driven mantle flow. We compare the results with plate kinematic reconstructions and other geological observations.

  13. Scaling of energy absorbing composite plates

    NASA Technical Reports Server (NTRS)

    Jackson, Karen; Morton, John; Traffanstedt, Catherine; Boitnott, Richard

    1992-01-01

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  14. Electrochemical Machining of Metal Plates

    SciTech Connect

    Cooper, J F; Evans, M C

    2005-03-04

    Electrochemical machining (ECM) with concentrated sodium chlorate electrolyte was used to rapidly cut a circular groove (13 cm diameter, 0.2 cm wide) through a 0.15 cm thick sheet of steel--thus opening a 5-inch porthole in as little as 10 minutes. The most favorable operating conditions were: T = 22 C; chlorate concentration 600 g NaClO{sub 3}/liter-solution; electric power of 100 A at 10 V; and flow of 0.5 l/s at a pressure drop of 10 kPa (1.5 psi). The porthole may be removed entirely by electrochemical means, or the electrochemical dissolution may continue until only thin membrane remains that is subsequently cut with a utility knife. An array of thermocouples was used to track temperature in the flowing solution and in the trough being machined; the maximum increase in temperature in the trough was 5 C over that of the flowing electrolyte which increased in temperature by 19 C because of power dissipation. ECM is shown feasible for rapid perforation of plates of ferrous and non-ferrous metals using portable equipment and commercial batteries. The technique can be extended to cut perforations of arbitrary shape through non-planar surfaces using a deformable ring cathode. Analysis of the power requirements for electrolyte flow and ECM indicate a total system weight of less than 45 kg (100 lb) using a commercial NiMH battery. The technique is recommended for reduction to practice and demonstration on full scale as an engineering prototype.

  15. Screen test for cadmium and nickel plates

    NASA Technical Reports Server (NTRS)

    Phan, Angie H.; Zimmerman, Albert H.

    1994-01-01

    A new procedure is described which was recently developed to quantify loading uniformity of nickel and cadmium plates and to screen finished electrodes prior to cell assembly. The technique utilizes the initial solubility rates of the active material in a standard chemical deloading solution at fixed conditions. The method can provide a reproducible indication of plate loading uniformity in situations where high surface loading limits the free flow of deloading solution into the internal porosity of the sinter plate. A preliminary study indicates that 'good' cell performance is associated with higher deloading rates.

  16. Laminated anisotropic reinforced plastic plates and shells

    NASA Technical Reports Server (NTRS)

    Korolev, V. I.

    1981-01-01

    Basic technical theories and engineering calculation equations for anisotropic plates and shells made of rigid reinforced plastics, mainly laminated fiberglass, are presented and discussed. Solutions are given for many problems of design of structural plates and shells, including curved sections and tanks, as well as two chapters on selection of the optimum materials, are given. Accounting for interlayer shearing and transverse separation, which are new engineering properties, are discussed. Application of the results obtained to thin three ply plates and shells wth a light elastic filler is presented and discussed.

  17. Modeling Residual Stresses in Ceramic Plates

    NASA Astrophysics Data System (ADS)

    Cantavella, V.; Moreno, A.; Mezquita, A.; Reig, Y.

    2008-02-01

    The generation of residual stresses during cooling of layered ceramic plates has been modeled. Each plate comprises a body and two thin layers (engobe and glaze). The model takes into account two types of stresses: thermal stresses, resulting from temperature gradients inside the plate during cooling, and the stresses produced by the mismatch of the coefficient of thermal expansion (CTE) of the layers. The body has been simulated using a linear viscoelastic constitutive equation. The engobe and the glaze layer have been considered as elastic solids below a certain temperature (setting temperature: Ta). Above Ta these two layers have no mechanical influence on the body.

  18. Bi-coolant flat plate solar collector

    NASA Astrophysics Data System (ADS)

    Chon, W. Y.; Green, L. L.

    The feasibility study of a flat plate solar collector which heats air and water concurrently or separately was carried out. Air flows above the collector absorber plate, while water flows in tubes soldered or brazed beneath the plate. The collector efficiencies computed for the flow of both air and water are compared with those for the flow of a single coolant. The results show that the bi-coolant collector efficiency computed for the entire year in Buffalo, New York is higher than the single-coolant collector efficiency, although the efficiency of the water collector is higher during the warmer months.

  19. Elastic buckling of tapered circular plates

    NASA Astrophysics Data System (ADS)

    Wang, C. M.; Hong, G. M.; Tan, T. J.

    1995-06-01

    This paper is concerned with the elastic buckling of tapered circular plates. The study is prompted by the fact that results hitherto available are restricted to a narrow range of taper parameters and are somewhat different from each other. For the buckling analysis, a simple and yet accurate numerical method is presented. It is based on the shooting method and the Rayleigh-Ritz approach. Comprehensive generic buckling results of circular plates with linearly and parabolically varying thicknesses are generated. Comparison studies of the buckling results showed that some of the existing results were erroneous. Optimal values of taper parameters for such tapered plates are also given.

  20. Vibration and buckling of super elliptical plates

    NASA Astrophysics Data System (ADS)

    Wang, C. M.; Wang, L.; Liew, K. M.

    1994-03-01

    This paper is concerned with the vibration and buckling of a new class of plates, the periphery shape of which is defined by a super elliptical function. Such a plate shape has practical applications, as the advantageous curved corners help to diffuse stress concentrations. The loading considered for the buckling problem is that of in-plane uniform pressure along the periphery. Accurate frequency and buckling factors are tabulated for such plates with either simply supported or clamped edges. The solutions are obtained using the pb - 2 Rayleigh-Ritz method.

  1. Seismic anisotropy above a subducting plate

    SciTech Connect

    Shih, X.R.; Meyer, R.P. ); Schneider, J.F. )

    1991-08-01

    Shear-wave splitting observed in northeastern Colombia has provided evidence of seismic anisotropy in a shear zone immediately above a subducting plate. In an upper mantle composed mainly of olivine (57%) and orthopyroxene (17%), the splitting can be interpreted by wave propagation in an anisotropic medium of orthorhombic symmetry that results from alignment of these intrinsically anisotropic minerals. The mechanism of alignment is most likely the shearing associated with the subduction, aided by fluids migrating from the subducting plate when the plate exceeds 100 km in depth.

  2. Strongly coupled stress waves in heterogeneous plates.

    NASA Technical Reports Server (NTRS)

    Wang, A. S. D.; Chou, P. C.; Rose, J. L.

    1972-01-01

    Consideration of coupled stress waves generated by an impulsive load applied at one end of a semiinfinite plate. For the field equations governing the one-dimensional coupled waves a hyperbolic system of equations is obtained in which a strong coupling in the second derivatives exists. The method of characteristics described by Chou and Mortimer (1967) is extended to cover the case of strong coupling, and a study is made of the transient stress waves in a semiinfinite plate subjected to an initial step input. Coupled discontinuity fronts are found to propagate at different velocities. The normal plate stress and the bending moment at different time regimes are illustrated by graphs.

  3. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  4. Modeling Residual Stresses in Ceramic Plates

    SciTech Connect

    Cantavella, V.; Moreno, A.; Mezquita, A.; Reig, Y.

    2008-02-15

    The generation of residual stresses during cooling of layered ceramic plates has been modeled. Each plate comprises a body and two thin layers (engobe and glaze). The model takes into account two types of stresses: thermal stresses, resulting from temperature gradients inside the plate during cooling, and the stresses produced by the mismatch of the coefficient of thermal expansion (CTE) of the layers. The body has been simulated using a linear viscoelastic constitutive equation. The engobe and the glaze layer have been considered as elastic solids below a certain temperature (setting temperature: T{sub a}). Above T{sub a} these two layers have no mechanical influence on the body.

  5. Electromagnetic semitransparent δ-function plate: Casimir interaction energy between parallel infinitesimally thin plates

    NASA Astrophysics Data System (ADS)

    Parashar, Prachi; Milton, Kimball A.; Shajesh, K. V.; Schaden, M.

    2012-10-01

    We derive boundary conditions for electromagnetic fields on a δ-function plate. The optical properties of such a plate are shown to necessarily be anisotropic in that they only depend on the transverse properties of the plate. We unambiguously obtain the boundary conditions for a perfectly conducting δ-function plate in the limit of infinite dielectric response. We show that a material does not “optically vanish” in the thin-plate limit. The thin-plate limit of a plasma slab of thickness d with plasma frequency ωp2=ζp/d reduces to a δ-function plate for frequencies (ω=iζ) satisfying ζd≪ζpd≪1. We show that the Casimir interaction energy between two parallel perfectly conducting δ-function plates is the same as that for parallel perfectly conducting slabs. Similarly, we show that the interaction energy between an atom and a perfect electrically conducting δ-function plate is the usual Casimir-Polder energy, which is verified by considering the thin-plate limit of dielectric slabs. The “thick” and “thin” boundary conditions considered by Bordag are found to be identical in the sense that they lead to the same electromagnetic fields.

  6. Thermo-mechanical buckling analysis of FGM plate using generalized plate theory

    NASA Astrophysics Data System (ADS)

    Sharma, Kanishk; Kumar, Dinesh; Gite, Anil

    2016-05-01

    This paper investigates the thermo-mechanical buckling behavior of simply-supported FGM plate under the framework of generalized plate theory (GPT), which includes classical plate theory (CPT), first order shear deformation theory (FSDT) and higher order shear deformation theory (HSDT) as special cases. The governing equations for FGM plate under thermal and mechanical loading conditions are derived from the principle of virtual displacements and Navier-type solution is assumed for simply supported boundary condition. The efficiency and applicability of presented methodology is illustrated by considering various examples of thermal and mechanical buckling of FGM plates. The closed form solutions in the form of critical thermal and mechanical buckling loads, predicted by CPT, FSDT and HSDT are compared for different side-to-thickness of FGM plate. Subsequently, the effect of material gradation profile on critical buckling parameters is examined by evaluating the buckling response for a range of power law indexes. The effect of geometrical parameters on mechanical buckling of FGM plate under uni-axial and bi-axial loading conditions are also illustrated by calculating the critical load for various values of slenderness ratios. Furthermore a comparative analysis of critical thermal buckling loads of FGM plate for different temperature profiles is also presented. It is identified that all plate theories predicted approximately same critical buckling loads and critical buckling temperatures for thin FGM plate, however for thick FGM plates, CPT overestimates the critical buckling parameters. Moreover the critical buckling loads and critical buckling temperatures of FGM plate are found to be significantly lower than the corresponding homogenous isotropic ceramic plate (n=0).

  7. Compressive strength of damaged and repaired composite plates

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1992-01-01

    Tests were performed assessing the effectiveness of repair in restoring the mechanical properties of damaged, solid composite plates made of Fiberite T300/976 graphite-epoxy. Some (75%) or all (100%) of the damaged zone was cut out, and the plate was repaired by plugging and patching the hole. The effectiveness of the repair was evaluated by measuring the compressive strengths of undamaged plates, damaged plates with no cutout, damaged plates with a cutout, and plates that had been repaired.

  8. Self-Aspirated Atmospheric Pressure Chemical Ionization Source for Direct Sampling of Analytes on Surfaces and in Liquid Solutions

    SciTech Connect

    Asano, Keiji G; Ford, Michael J; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    A self-aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self-aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed-phase thin-layer chromatography plate in which a three-component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full-scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol(reg. sign) and Evista(reg. sign) tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384-well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine-d{sub 3} as an internal standard.

  9. Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions.

    PubMed

    Asano, Keiji G; Ford, Michael J; Tomkins, Bruce A; Van Berkel, Gary J

    2005-01-01

    A self-aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self-aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed-phase thin-layer chromatography plate in which a three-component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full-scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol and Evista tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384-well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine-d3 as an internal standard.

  10. 30 CFR 18.11 - Approval plate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... extension(s) of approval were based. (d) A completely assembled approved machine with an integral dust collector shall bear an approval plate indicating that the requirements of part 33 of this chapter...

  11. Coloured Rings Produced on Transparent Plates

    ERIC Educational Resources Information Center

    Suhr, Wilfried; Schlichting, H. Joachim

    2007-01-01

    Beautiful colored interference rings can be produced by using transparent plates such as window glass. A simple model explains this effect, which was described by Newton but has almost been forgotten. (Contains 11 figures.)

  12. Optimal stabilization of indefinite plate buckling problems

    NASA Astrophysics Data System (ADS)

    Chase, J. Geoffrey; Bhashyam, Srinivas

    2001-08-01

    Indefinite plate buckling problems arise when the applied load case results in buckling loads which are not all of the same sign. Examples include the important cases of shear buckling and general combinations of tensile and compressive in-plane edge loads. Optimal controllers which actively stabilize these general, indefinite plate buckling problems, by transforming them into a system of definite plate buckling problems, are presented. Important features of this approach include the ability to select the designed closed loop critical buckling load, and to pre-determine what load cases a given controller will stabilize when the exact load combination varies or is unknown. This last result enables the control designer to know exactly, by design, what load combinations will be stabilized. A numerical example is presented where the controllers developed are employed to stabilize multiple, definite and indefinite buckling modes for laminated composite plates similar to aircraft wing skins.

  13. Vibro-acoustic analysis of composite plates

    NASA Astrophysics Data System (ADS)

    Sarigül, A. S.; Karagözlü, E.

    2014-03-01

    Vibro-acoustic analysis plays a vital role on the design of aircrafts, spacecrafts, land vehicles and ships produced from thin plates backed by closed cavities, with regard to human health and living comfort. For this type of structures, it is required a coupled solution that takes into account structural-acoustic interaction which is crucial for sensitive solutions. In this study, coupled vibro-acoustic analyses of plates produced from composite materials have been performed by using finite element analysis software. The study has been carried out for E-glass/Epoxy, Kevlar/Epoxy and Carbon/Epoxy plates with different ply angles and numbers of ply. The effects of composite material, ply orientation and number of layer on coupled vibro-acoustic characteristics of plates have been analysed for various combinations. The analysis results have been statistically examined and assessed.

  14. Characterization of Tri-lab Tantalum Plate.

    SciTech Connect

    Buchheit, Thomas E.; Cerreta, Ellen K.; Deibler, Lisa Anne; Chen, Shu-Rong; Michael, Joseph R.

    2014-09-01

    This report provides a detailed characterization Tri-lab Tantalum (Ta) plate jointly purchased from HCStark Inc. by Sandia, Los Alamos and Lawrence Livermore National Laboratories. Data in this report was compiled from series of material and properties characterization experiments carried out at Sandia (SNL) and Los Alamos (LANL) Laboratories through a leveraged effort funded by the C2 campaign. Results include microstructure characterization detailing the crystallographic texture of the material and an increase in grain size near the end of the rolled plate. Mechanical properties evaluations include, compression cylinder, sub-scale tension specimen, micohardness and instrumented indentation testing. The plate was found to have vastly superior uniformity when compare with previously characterized wrought Ta material. Small but measurable variations in microstructure and properties were noted at the end, and at the top and bottom edges of the plate.

  15. The Continental Plates are Getting Thicker.

    ERIC Educational Resources Information Center

    Kerr, Richard A.

    1986-01-01

    Reviews seismological studies that provide evidence of the existence of continental roots beneath the continents. Suggests, that through the collisions of plate tectonics, continents stabilized part of the mobile mantle rock beneath them to form deep roots. (ML)

  16. Stop motion microphotography of laser driven plates

    SciTech Connect

    Frank, A.M.; Trott, W.M.

    1994-09-01

    Laser driven plates have been used for several years for high velocity shock wave and impact studies. Recent questions about the integrity and ablation rates of these plates coupled with an improved capability for microscopic stop motion photography led to this study. For these experiments, the plates were aluminum, coated on the ends of optical fibers. A high power laser pulse in the fiber ionizes the aluminum at the fiber/coating interface. The plasma thus created accelerates the remaining aluminum to high velocities, several kilometers per second. We defined {open_quotes}thick{close_quotes} or {open_quotes}thin{close_quotes} coatings as those where a flying plate (flyer) was launched vs. the material being completely ionized. Here we were specifically interested in the thick/thin boundary to develop data for the numerical models attempting to predict flyer behavior.

  17. A clamped rectangular plate containing a crack

    NASA Technical Reports Server (NTRS)

    Tang, R.; Erdogan, F.

    1985-01-01

    The general problem of a rectangular plate clamped along two parallel sides and containing a crack parallel to the clamps is considered. The problem is formulated in terms of a system of singular integral equations and the asymptotic behavior of the stress state near the corners is investigated. Numerical examples are considered for a clamped plate without a crack and with a centrally located crack, and the stress intensity factors and the stresses along the clamps are calculated.

  18. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  19. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-01-01

    A fuel cell includes a separator plate having first and second flow channels extending therethrough contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are suplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material.

  20. Plate Tectonics, Geographical Information System, paleogeography

    SciTech Connect

    Moore, Thomas L.; Scotese, Christopher

    2002-05-24

    The PaleoX.framwork is a dynamically linked/loaded framework for Cocoa applications. The primary goal of this library is to standardize several elements used for working with paleogeographic data. This includes objects designed to organize information for tectonic plates, including maps, rotation objects, plate names, and designations. In addition, PaleoX provides object-oriented solutions for handling standard paleogeographic file formats from the PALEOMAP Project.

  1. Tomography, the geoid and plate motions

    NASA Technical Reports Server (NTRS)

    Gable, Carl W.; O'Connell, Richard J.

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period.

  2. Lighting system with heat distribution face plate

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  3. Reconstructing Plate Motions on Europa with GPlates

    NASA Astrophysics Data System (ADS)

    Cutler, B. B.; Collins, G. C.; Prockter, L. M.; Patterson, G.; Kattenhorn, S. A.; Rhoden, A.; Cooper, C. M.

    2015-12-01

    Observations of past plate tectonic - like motions in Europa's icy lithosphere have been reported in previous studies. Quantifying the nature, age, and amount of plate motion is important for geophysical models of Europa's ice shell and for astrobiology, since subsumed pates could drive the flow of nutrients into the subsurface ocean. We have used GPlates software (Williams et al., GSA Today 2012) and a mosaic of regional-resolution Galileo SSI data from orbits E11, E15, E17, and E19 to make interactive reconstructions of both the Northern Falga region (60N, 220W) and the Castalia Macula region (0N, 225W). The advantage of this method is that plate motions are calculated on a sphere, while still maintaining the original Galileo image pieces in their proper geographic locations. Previous work on the Castalia Macula region (Patterson et al. J.Struct.Geol. 2006) and the adjacent Phaidra Linea region (Patterson and Ernst, LPSC 2011) found offsets along spreading boundaries, and then calculated the best fit finite rotations to close those offsets. Though this method is mathematically rigorous and gives a statistical goodness of fit, it is not easy to test multiple hypotheses for candidate piercing points or divisions of candidate plate boundaries. Through the interactive environment, we found that we could better account for observed offsets in this region by breaking it into 32 different plates. Patterson and Ernst broke the Phaidra region into 6 plates which exhibited nonrigid behavior, where our study breaks it into 16 rigid plates. The Northern Falga Regio area is interesting due to the potential for large amounts of subsumption of Europa's icy crust in this location. The previous reconstruction (Kattenhorn and Prockter, Nat.Geosci. 2014) was based on planar geometry, and we have replicated these results using a spherically-based reconstruction. We will present the plate maps and reconstructions for both of these regions, along with the best fit rotation poles.

  4. Method for plating with metal oxides

    DOEpatents

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  5. Method for plating with metal oxides

    SciTech Connect

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  6. Predicting Farnsworth Lantern success with a six-plate series of the Ishihara pseudoisochromatic plates.

    PubMed

    Hackman, R J

    2001-12-01

    The Farnsworth Lantern (FALANT) is the definitive color vision test for the Navy, Marine Corps, and Coast Guard. It is also the definitive color vision test for aviation personnel in the Army. Results from it are also accepted by the Federal Aviation Administration. For various reasons, it is desirable to have an alternative test that can predict success (i.e., a passing score) on the FALANT. In 1991, it was shown that a 14-plate series of Ishihara pseudoisochromatic plates could predict FALANT success provided the proper passing criteria was chosen. Interest has arisen regarding whether or not a 6-plate series of Ishihara plates can predict FALANT success. A study was undertaken to answer this question. It appears that a 6-plate series of Ishihara pseudoisochromatic plates can predict FALANT success.

  7. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    PubMed

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones.

  8. Vibration of Rectangular Plates Using Plate Characteristic Functions as Shape Functions in the RAYLEIGH RITZ Method

    NASA Astrophysics Data System (ADS)

    Rajalingham, C.; Bhat, R. B.; Xistris, G. D.

    1996-06-01

    The plate characteristic functions are used to express the deflection shapes in the Rayleigh-Ritz method to study rectangular plate vibrations. Since the plate characteristic functions are reasonable approximations to the vibration modes, they are found to improve the convergence of vibration frequencies. These plate frequencies are used to check the accuracy of the Rayleigh frequencies associated with the plate characteristic function modes. Computations are carried out for each of the four mode categories of a clamped square plate. In each mode category, the first 30 natural frequencies are tabulated and the first nine mode diagrams are drawn. The results show that the choice of specific shape functions enhances the effectiveness of the Rayleigh-Ritz method.

  9. Abrupt plate accelerations shape rifted continental margins

    NASA Astrophysics Data System (ADS)

    Brune, Sascha; Williams, Simon E.; Butterworth, Nathaniel P.; Müller, R. Dietmar

    2016-08-01

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth’s major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength–velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time.

  10. Abrupt plate accelerations shape rifted continental margins.

    PubMed

    Brune, Sascha; Williams, Simon E; Butterworth, Nathaniel P; Müller, R Dietmar

    2016-08-11

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth's major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength--velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time.

  11. Modeling the hydrodynamics of Phloem sieve plates.

    PubMed

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele; Bohr, Tomas; Knoblauch, Michael; Bruus, Henrik

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  12. The planar jet-plate oscillator

    NASA Astrophysics Data System (ADS)

    Arthurs, David; Ziada, Samir

    2011-01-01

    The aeroacoustic noise generated by a high speed, planar gas jet impinging on a flat plate is investigated experimentally. The jet used in this study is typical of those commonly found in industrial applications such as in various coating control and heat transfer processes. Normal jet impingement on the plate is found to generate strong acoustic tones over a wide range of impingement distances and jet velocities. The characteristics of these tones, as a function of the jet velocity and impingement distance, are quantified. Phase and amplitude measurements of the pressure fluctuations on the impingement plate indicate that the acoustic tones are generated by an antisymmetric instability mode of the jet oscillation. The effect of plate inclination in both the transverse and span-wise directions, with respect to the incident jet, is also studied. The jet-plate tone is found to be much more sensitive to changes in the span-wise plate inclination than to changes in the transverse inclination, but in both cases, a complete suppression of the tone is found to be possible.

  13. Optimization of a clamped plate silencer.

    PubMed

    Wang, Chunqi; Han, Jun; Huang, Lixi

    2007-02-01

    A previous theoretical study [L. Huang, J. Acoust. Soc. Am. 119, 2628-2638 (2006)] shows that, in a duct, a simply supported plate covering a side-branch rigid cavity can function effectively as a wave reflector over a broad range of low to medium frequencies. In this study, analytical formulation is extended to the boundary condition of clamped plate, which is easier to implement in practice. The theoretical model is tested experimentally using balsawood, which has a very high stiffness to mass ratio. The spectral peaks and shapes of the measured TL are in agreement with those calculated theoretically, attempts are also made to account for the considerable sound absorption in the rig. Further numerical studies based on the validated model show that, for a uniform plate, the optimal stopband is narrower and the lower band limit is worse than that of the simply supported configuration. However, a wave reflector using nonuniform, clamped plates with thinner ends out-performs the simply supported configuration in every aspect. Analyses show that the improvement is attributed to the increased acoustic radiation efficiency over the bulk length of the nonuniform plate, which behaves more like a rigid plate.

  14. Corrosion test cell for bipolar plates

    DOEpatents

    Weisbrod, Kirk R.

    2002-01-01

    A corrosion test cell for evaluating corrosion resistance in fuel cell bipolar plates is described. The cell has a transparent or translucent cell body having a pair of identical cell body members that seal against opposite sides of a bipolar plate. The cell includes an anode chamber and an cathode chamber, each on opposite sides of the plate. Each chamber contains a pair of mesh platinum current collectors and a catalyst layer pressed between current collectors and the plate. Each chamber is filled with an electrolyte solution that is replenished with fluid from a much larger electrolyte reservoir. The cell includes gas inlets to each chamber for hydrogen gas and air. As the gases flow into a chamber, they pass along the platinum mesh, through the catalyst layer, and to the bipolar plate. The gas exits the chamber through passageways that provide fluid communication between the anode and cathode chambers and the reservoir, and exits the test cell through an exit port in the reservoir. The flow of gas into the cell produces a constant flow of fresh electrolyte into each chamber. Openings in each cell body is member allow electrodes to enter the cell body and contact the electrolyte in the reservoir therein. During operation, while hydrogen gas is passed into one chamber and air into the other chamber, the cell resistance is measured, which is used to evaluate the corrosion properties of the bipolar plate.

  15. Data analysis for surface plate calibration

    SciTech Connect

    Burton, R.N.

    1997-08-01

    A surface plate is used to establish a reference plane used for making precision dimensional measurements. Ideally, the surface should be perfectly flat. Since it is impossible to create a perfectly flat surface, surface plate are calibrated to determine how much they deviate from a perfectly flat surface. Once a surface plate is calibrated, the user can determine if the plate is flat enough for use in a particular application. The currently accepted method of data analysis for surface plate calibration, the Moody method, does not give optimum results because of the arbitrary way in which the reference plane is chosen. The exact solution, wherein the reference plane is located in the optimum position, has been worked out and is given in a step by step procedure along with all of the necessary equations. The amount of calculation involved in a typical example proved to be prohibitive even for a computer, so an alternate solution using a least squares criterion for locating the reference plane was developed. Results were comparable with those from Moody`s method with values being smaller or greater depending on the shape of the plate.

  16. Vibration analysis of annular-like plates

    NASA Astrophysics Data System (ADS)

    Cheng, L.; Li, Y. Y.; Yam, L. H.

    2003-05-01

    The existence of eccentricity of the central hole for an annular plate results in a significant change in the natural frequencies and mode shapes of the structure. In this paper, the vibration analysis of annular-like plates is presented based on numerical and experimental approaches. Using the finite element analysis code Nastran, the effects of the eccentricity, hole size and boundary condition on vibration modes are investigated systematically through both global and local analyses. The results show that analyses for perfect symmetric conditions can still roughly predict the mode shapes of "recessive" modes of the plate with a slightly eccentric hole. They will, however, lead to erroneous results for "dominant" modes. In addition, the residual displacement mode shape is verified as an effective parameter for identifying damage occurring in plate-like structures. Experimental modal analysis on a clamped-free annular-like plate is performed, and the results obtained reveal good agreement with those obtained by numerical analysis. This study provides guidance on modal analysis, vibration measurement and damage detection of plate-like structures.

  17. Abrupt plate accelerations shape rifted continental margins.

    PubMed

    Brune, Sascha; Williams, Simon E; Butterworth, Nathaniel P; Müller, R Dietmar

    2016-08-11

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth's major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength--velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time. PMID:27437571

  18. Diffuse oceanic plate boundaries: Strain rates, vertically averaged rheology, and comparisons with narrow plate boundaries and stable plate interiors

    NASA Astrophysics Data System (ADS)

    Gordon, Richard G.

    Diffuse plate boundaries occur in both oceanic and continental lithosphere and cover ≈ 15% of Earth's solid surface. The fastest plate speeds accommodated across diffuse oceanic plate boundaries are ≈ 15 mm/yr. The smallest strain rates averaged across narrow plate boundaries are at least 102 times larger than the largest strain rates across diffuse oceanic plate boundaries and at least 102 times larger than those across stable plate interiors. The effective viscosity (ηeff) of the lithosphere is estimated from the ratio of vertically averaged shear stresses to strain rates for three tectonic settings: (i) oceanic transform fault zones, for which ηeff = 3 ×1016 to 5×1019 Pa s, comparable to estimates for the asthenosphere, (ii) diffuse oceanic plate boundaries, for which ηeff = 1×1023 to 6×l023 Pa s, ≈ 10 times larger than for diffuse continental plate boundaries, and (iii) stable plate interiors, for which ηeff = 1x1024 to 2×1027 Pa s. The rheology of oceanic lithosphere over times longer than earthquake cycles is modeled as a plastic layer overlying a layer that deforms by creeping flow [Martinod and Davy, 1992]. Oceanic lithosphere deforms when the yield strength of the upper lithosphere is exceeded. The vertically averaged rheology of deforming oceanic lithosphere can be approximated by a power-law fluid for which ɛ. ∝ (τs)n where ɛ. is the rate of shear strain and τs is the shear stress. If the ratio of the yield strength of the upper lithosphere to the force required to deform the lower lithosphere at a strain rate of 10-16 s-1 is varied from 10-2 to 102 , the calculated value of n varies from ≈3 to ≈300. The map-view aspect ratio of a deforming zone in a thin sheet of power-law fluid is proportional to n-½ [England et al., 1985]. A profile of displacement versus distance inferred from a seismic profile across the Central Indian Basin (India-Capricorn diffuse oceanic plate boundary), where the lithosphere is about 60-Myr old

  19. Vibration Analysis of Rectangular Isotropic Thick Plates Using Mindlin Plate Characteristic Functions

    NASA Astrophysics Data System (ADS)

    Lee, J. M.; Kim, K. C.

    1995-11-01

    An iterative Kantorovich method is presented for the vibration analysis of rectangular isotropic thick plates. Mindlin plate characteristic functions are derived in general forms by the Kantorovich method initially starting with Timoshenko beam functions consistent with the boundary conditions of the plate. Through numerical calculations of a natural pairs and dynamic responses of appropriate models, it has been confirmed that the method presented is superior to the Rayleigh-Ritz analysis or the FEM analysis in accuracy and computational efficiency.

  20. Current plate velocities relative to the hotspots incorporating the NUVEL-1 global plate motion model

    SciTech Connect

    Gripp, A.E.; Gordon, R.G. )

    1990-07-01

    NUVEL-1 is a new global model of current relative plate velocities which differ significantly from those of prior models. Here the authors incorporate NUVEL-1 into HS2-NUVEL1, a new global model of plate velocities relative to the hotspots. HS2-NUVEL1 was determined from the hotspot data and errors used by Minster and Jordan (1978) to determine AM1-2, which is their model of plate velocities relative to the hotspots. AM1-2 is consistent with Minster and Jordan's relative plate velocity model RM2. Here the authors compare HS2-NUVEL1 with AM1-2 and examine how their differences relate to differences between NUVEL-1 and RM2. HS2-NUVEL1 plate velocities relative to the hotspots are mainly similar to those of AM1-2. Minor differences between the two models include the following: (1) in HS2-NUVEL1 the speed of the partly continental, apparently non-subducting Indian plate is greater than that of the purely oceanic, subducting Nazca plate; (2) in places the direction of motion of the African, Antarctic, Arabian, Australian, Caribbean, Cocos, Eurasian, North American, and South American plates differs between models by more than 10{degree}; (3) in places the speed of the Australian, Caribbean, Cocos, Indian, and Nazca plates differs between models by more than 8 mm/yr. Although 27 of the 30 RM2 Euler vectors differ with 95% confidence from those of NUVEL-1, only the AM1-2 Arabia-hotspot and India-hotspot Euler vectors differ with 95% confidence from those of HS2-NUVEL1. Thus, substituting NUVEL-1 for RM2 in the inversion for plate velocities relative to the hotspots changes few Euler vectors significantly, presumably because the uncertainty in the velocity of a plate relative to the hotspots is much greater than the uncertainty in its velocity relative to other plates.

  1. Thermal stresses and deflections of cross-ply laminated plates using refined plate theories

    NASA Technical Reports Server (NTRS)

    Khdeir, A. A.; Reddy, J. N.

    1991-01-01

    Exact analytical solutions of refined plate theories are developed to study the thermal stresses and deflections of cross-ply rectangular plates. The state-space approach in conjunction with the Levy method is used to solve exactly the governing equations of the theories under various boundary conditions. Numerical results of the higher-order theory of Reddy for thermal stresses and deflections are compared with those obtained using the classical and first-order plate theories.

  2. Wavelength calibration of objective prism plates by transformation from direct plates

    NASA Astrophysics Data System (ADS)

    Tucholke, Hans-Joachim

    The zero points for galaxy redshift measurements from objective prison plates are obtained through the transformation of object positions from the corresponding direct plates. About 1000 G-stars per plate are employed. The transformation characteristics for three adjacent fields near the South Galactic Pole are presented. The mean residuals are about 5 microns, corresponding to a redshift error of about 700 km/s at z = 0.

  3. The present-day number of tectonic plates

    NASA Astrophysics Data System (ADS)

    Harrison, Christopher G. A.

    2016-03-01

    The number of tectonic plates on Earth described in the literature has expanded greatly since the start of the plate tectonic era, when only about a dozen plates were considered in global models of present-day plate motions. With new techniques of more accurate earthquake epicenter locations, modern ways of measuring ocean bathymetry using swath mapping, and the use of space based geodetic techniques, there has been a huge growth in the number of plates thought to exist. The study by Bird (2003) proposed 52 plates, many of which were delineated on the basis of earthquake locations. Because of the pattern of areas of these plates, he suggested that there should be more small plates than he could identify. In this paper, I gather together publications that have proposed a total of 107 new plates, giving 159 plates in all. The largest plate (Pacific) is about 20 % of the Earth's area or 104 Mm2, and the smallest of which (Plate number 5 from Hammond et al. 2011) is only 273 km2 in area. Sorting the plates by size allows us to investigate how size varies as a function of order. There are several changes of slope in the plots of plate number organized by size against plate size order which are discussed. The sizes of the largest seven plates is constrained by the area of the Earth. A middle set of 73 plates down to an area of 97,563 km2 (the Danakil plate at number 80, is the plate of median size) follows a fairly regular pattern of plate size as a function of plate number. For smaller plates, there is a break in the slope of the plate size/plate number plot and the next 32 plates follow a pattern of plate size proposed by the models of Koehn et al. (2008) down to an area of 11,638 km2 (West Mojave plate # 112). Smaller plates do not follow any regular pattern of area as a function of plate number, probably because we have not sampled enough of these very small plates to reveal any clear pattern.

  4. Caribbean plate tectonics from seismic tomography

    NASA Astrophysics Data System (ADS)

    Ten Brink, U. S.; Villasenor, A.

    2012-12-01

    New seismic tomography in the Caribbean shows close links between the geometry and dynamics of subducting slabs and the geology of the overriding plate. Unlike most oceanic plates, the Caribbean plate lacks identifiable seafloor magnetic anomalies and fracture zones. The plate's history has therefore been inferred primarily from land geology along the plate boundary, which is complicated by large-scale shear deformation, and from finite rotations of surrounding plates.We used more than 14 million arrival times from 300,000 earthquakes to identify P-wave velocity anomalies. We relate the anomalies to the geometry and dynamics of subducting slabs and to patterns of earthquake activity, volcanism, topographic relief, and tectonic deformation. For example, we detect two separate slabs belonging to the North and South American plates, respectively, which appear to be responsible for morphologic and tectonic differences between the arcs of the Northern (from Guadeloupe northward) and Southern (from Dominica southward) Lesser Antilles. Variations in earthquake activity between Haiti and the Dominican Republic can be explained by a change in slab geometry from an underplated slab beneath Haiti to a subducting slab under the Dominican Republic. A shallow tear in the slab may explain the anomalously deep Puerto Rico Trench and the frequent earthquake swarms there. The westward shift in volcanic activity in the Northern Lesser Antilles from the Miocene Limestone Caribbees to the present arc can be attributed to the limit on convective flow imposed by the 3-D geometry of the slab at depth. A thinned South America slab under the southern Lesser Antilles may result from traction imposed on the slab by a wide forearc wedge. Variations in tectonic deformation of northern South America could be related to the location of the Caribbean Large Igneous Province north of the Maracaibo Block.

  5. Motion of the Scotia sea plates

    USGS Publications Warehouse

    Thomas, C.; Livermore, R.; Pollitz, F.

    2003-01-01

    Earthquake data from the Scotia Arc to early 2002 are reviewed in the light of satellite gravity and other data in order to derive a model for the motion of plates in the Scotia Sea region. Events with magnitude ???5, which occurred on or near the boundaries of the Scotia and Sandwich plates, and for which Centroid Moment Tensor (CMT) solutions are available, are examined. The newer data fill some of the previous sampling gaps along the boundaries of the Scotia and Sandwich plates, and provide tighter constraints on relative motions. Variations in the width of the Brunhes anomaly on evenly spaced marine magnetic profiles over the East Scotia Ridge provide new estimates of Scotia-Sandwich plate spreading rates. Since there are no stable fracture zones in the east Scotia Sea, the mean azimuth of sea floor fabric mapped by sidescan is used to constrain the direction of spreading. 18 new rate estimates and four azimuths from the East Scotia Ridge are combined with 68 selected earthquake slip vectors from the boundaries of the Scotia Sea in a least-squares inversion for the best-fitting set of Euler poles and angular rotation rates describing the 'present-day' motions of the Scotia and Sandwich plates relative to South America and Antarctica. Our preferred model (TLP2003) gives poles that are similar to previous estimates, except for Scotia Plate motion with respect to South America, which is significantly different from earlier estimates; predicted rates of motion also differ slightly. Our results are much more robust than earlier work. We examine the implications of the model for motion and deformation along the various plate boundaries, with particular reference to the North and South Scotia Ridges, where rates are obtained by closure.

  6. Large Deflections of Elastic Rectangular Plates

    NASA Astrophysics Data System (ADS)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  7. 49 CFR 451.21 - Safety approval plate required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Safety approval plate required. 451.21 Section 451... HOMELAND SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.21 Safety approval plate required. (a) The safety approval plate must be supplied by...

  8. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  9. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  10. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  11. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  12. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  13. Making More Efficient Use Of Battery-Plate Mass

    NASA Technical Reports Server (NTRS)

    Rowlette, John J.

    1990-01-01

    Improved active material for positive plate of lead/acid electric storage battery made with additional porosity to give electrolyte access to larger plate-surface area. 65 to 68 percent of active mass of plate used to generate electric current. Batteries with new plate material offer extremely long cycle life.

  14. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  15. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  16. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  17. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  18. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  19. LOWLID FORMATION AND PLATE TECTONICS ON EXOPLANETS

    NASA Astrophysics Data System (ADS)

    Stamenkovic, V.; Noack, L.; Breuer, D.

    2009-12-01

    The last years of astronomical observation have opened the doors to a universe filled with extrasolar planets. Detection techniques still only offer the possibility to detect mainly Super-Earths above five Earth masses. But detection techniques do steadily improve and are offering the possibility to detect even smaller planets. The observations show that planets seem to exist in many possible sizes just as the planets and moons of our own solar system do. It is only a natural question to ask if planetary mass has an influence on some key habitability factors such as on plate tectonics, allowing us to test which exoplanets might be more likely habitable than others, and allowing us to understand if plate tectonics on Earth is a stable or a critical, instable process that could easily be perturbed. Here we present results derived from 1D parameterized thermal evolution and 2D/3D computer models, showing how planetary mass influences the propensity of plate tectonics for planets with masses ranging from 0.1 to 10 Earth masses. Lately [2, 3] studied the effect of planetary mass on the ability to break plates and hence initiate plate tectonics - but both derived results contradictory to the other. We think that one of the reasons why both studies [2, 3] are not acceptable in their current form is partly due to an oversimplification. Both treated viscosity only temperature-dependent but neglected the effect pressure has on enlarging the viscosity in the deep mantle. More massive planets have therefore a stronger pressure-viscosity-coupling making convection at high pressures sluggish or even impossible. For planets larger than two Earth masses we observe that a conductive lid (termed low-lid) forms above the core-mantle boundary and thus reduces the effective convective part of the mantle when including a pressure-dependent term into the viscosity laws as shown in [1]. Moreover [2, 3] use time independent steady state models neglecting the fact that plate tectonics is a

  20. Ridge push engine of plate tectonics

    NASA Astrophysics Data System (ADS)

    Swedan, N. H.

    2015-07-01

    Convection of the upper mantle drives the tectonic plates. This convection is a thermodynamic cycle that exchanges heat and mechanical work between mantle and tectonic plates. Thermodynamics and observations indicate that the energy of the geological activities resulting from plate tectonics is equal to the latent heat of melting, calculated at mantle's pressure, of the new ocean crust regenerated at midocean ridges. This energy varies with the temperature of ocean floor, which is correlated with surface temperature. The main objective of this manuscript is to demonstrate that plate tectonics is a thermodynamic engine and can be calculated as such. Unlike existing tectonic models, the thermodynamic model is very sensitive to variations of the temperature of ocean floor, which is correlated with surface temperature. Therefore, the observed increase of geological activities can be projected with surface temperature rise. Other objectives of the manuscript are to calculate the force that drives the tectonic plates, estimate the energy released, and validate the calculations based on experiments and observations. In addition to the scientific merit of projecting the geological activities, a good projection can have a broader impact at the societal and economical levels. Investment and insurance related decisions are affected by climate change, and our ability to project the geological activities is of paramount importance for the economy and public safety. This work can thus provide tools to assess the risks and hazards associated with the trend of geological activities with surface temperature rise.

  1. Automatic Digital Plate Reading for Surveillance Cultures.

    PubMed

    Kirn, Thomas J

    2016-10-01

    The automation of specimen processing and culture workup has rapidly emerged in clinical microbiology laboratories throughout the world and more recently in the United States. While many U.S. laboratories have implemented some form of automated specimen processing and some have begun performing digital plate reading, automated colony analysis is just beginning to be utilized clinically. In this issue of the Journal of Clinical Microbiology, M. L. Faron et al. (J Clin Microbiol 54:2470-2475, 2016, http://dx.doi.org/10.1128/JCM.01040-16) report the results of their evaluation of the performance of the WASPLab Chromogenic Detection Module (CDM) for categorizing chromogenic agar plates as negative or "nonnegative" for vancomycin-resistant enterococci (VRE). Their major finding was 100% sensitivity for detection of "nonnegative" specimens using CDM compared to manual methods for specimens plated on two different types of VRE chromogenic agar plates. Additionally, utilization of digital plate reading in conjunction with automated colony analysis was predicted to result in significant savings based on greatly reduced labor costs.

  2. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  3. Geometrically nonlinear behavior of piezoelectric laminated plates

    NASA Astrophysics Data System (ADS)

    Rabinovitch, Oded

    2005-08-01

    The geometrically nonlinear behavior of piezo-laminated plates actuated with isotropic or anisotropic piezoelectric layers is analytically investigated. The analytical model is derived using the variational principle of virtual work along with the lamination and plate theories, the von Karman large displacement and moderate rotation kinematic relations, and the anisotropic piezoelectric constitutive laws. A solution strategy that combines the approach of the method of lines, the advantages of the finite element concept, and the variational formulation is developed. This approach yields a set of nonlinear ordinary differential equations with nonlinear boundary conditions, which are solved using the multiple-shooting method. Convergence and verification of the model are examined through comparison with linear and nonlinear results of other approximation methods. The nonlinear response of two active plate structures is investigated numerically. The first plate is actuated in bending using monolithic piezoceramic layers and the second one is actuated in twist using macro-fiber composites. The results quantitatively reveal the complicated in-plane stress state associated with the piezoelectric actuation and the geometrically nonlinear coupling of the in-plane and out-of-plane responses of the plate. The influence of the nonlinear effects ranges from significant stiffening in certain combinations of electrical loads and boundary conditions to amplifications of the induced deflections in others. The paper closes with a summary and conclusions.

  4. Recovery process for electroless plating baths

    DOEpatents

    Anderson, R.W.; Neff, W.A.

    1992-05-12

    A process is described for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO[sub 3]. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths. 18 figs.

  5. Recovery process for electroless plating baths

    DOEpatents

    Anderson, Roger W.; Neff, Wayne A.

    1992-01-01

    A process for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO.sub.3. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths.

  6. The flexural vibration of welded rectangular plates

    NASA Astrophysics Data System (ADS)

    Kaldas, M. M.; Dickinson, S. M.

    1981-03-01

    A theoretical and experimental study of the effect of weld runs on the flexural vibrational characteristics of the common structural element, the rectangular plate, is described. A finite difference technique is utilized for the determination of the in-plane residual stress pattern due to the weld(s) and the Rayleigh-Ritz method, with beam characteristic functions, is used for the out-of-plane vibration analysis. The theoretical approach presented is applicable to rectangular plates of any practical aspect ratio, having any combination of out-of-plane boundary conditions for which beam functions may reasonably be used and subject to one or more weld runs parallel to any edge. Theoretical and experimental results for a number of specific plates are presented, demonstrating the effects of welding on the plate vibration and the capability and accuracy of the analytical approach in predicting these effects. Included is a study of the effect of using the full residual stress pattern as derived from the finite difference analysis, the effect of neglecting certain stress components and the effect of using simplified stress patterns developed primarily for the stress and buckling analysis of long plates.

  7. Spirit Begins Drive Around Home Plate

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The hazard avoidance camera on the front of NASA's Mars Exploration Rover Spirit took this image after a drive by Spirit on the 1,829th Martian day, or sol, of Spirit's mission on the surface of Mars (Feb. 24, 2009).

    On Sol 1829, Spirit drove 6.29 meters (21 feet) northwestward, away from the northern edge of the low plateau called 'Home Plate.' The track dug by the dragged right-front wheel as the rover drove backward is visible in this image, receding toward the southeast. Rock layers of the northern slope of Home Plate are visible in the upper right portion of the image.

    In sols prior to 1829, the rover team had been trying to maneuver Spirit to climb onto the northern edge of Home Plate, ready to drive southward across the top of the plateau toward science destinations south of Home Plate. The Sol 1829 drive was the first move of a revised strategy to circle at least partway around Home Plate on the trek toward the sites south of the plateau.

  8. Computer animation of Phanerozoic plate motions

    SciTech Connect

    Scotese, C.R. . Dept. of Geology)

    1992-01-01

    Since 1985, the PALEOMAP Project, in collaboration with research groups both in the US and abroad, has assembled a digital model that describes global plate motions during the last 600 million years. In this paper the authors present a series of computer animations that dynamically illustrates the movement of continents and terranes, and the evolution of the ocean basins since the breakup of the late Precambrian supercontinent. These animations depict the motion of the plates from both equatorial and polar perspectives. Mesozoic and Cenozoic plate tectonic reconstructions are based on a synthesis of linear magnetic anomalies, fracture zone locations, intracontinental rifts, collision and thrust belts, and zones of strike-slip. Paleozoic plate reconstructions, though more speculative, are based on evidence of past subduction, continental collision, and inferred sea floor spreading. The relative longitudinal positions of the continents during the Paleozoic and the width of intervening oceans have been adjusted to best explain changing biogeographic and paleoclimatic patterns. A new paleomagnetic/hot spot reference frame has been constructed that combines paleomagnetic data compiled by Rob Van der Voo (1992) with inferred motion relative to a fixed frame of hot spots. Using probable Early Mesozoic and Paleozoic hot spot tracks on the major continents, the authors have extended plate motions relative to the hot spot reference frame back to 400 million years.

  9. Current plate motions. [continental groupings and global modelling

    NASA Technical Reports Server (NTRS)

    Demets, C.; Gordon, R. G.; Argus, D. F.; Stein, S.

    1990-01-01

    A global plate motion model, named NUVEL-1, which describes current plate motions between 12 rigid plates is described, with special attention given to the method, data, and assumptions used. Tectonic implications of the patterns that emerged from the results are discussed. It is shown that wide plate boundary zones can form not only within the continental lithosphere but also within the oceanic lithosphere; e.g., between the Indian and Australian plates and between the North American and South American plates. Results of the model also suggest small but significant diffuse deformation of the oceanic lithosphere, which may be confined to small awkwardly shaped salients of major plates.

  10. Active faults, stress field and plate motion along the Indo-Eurasian plate boundary

    NASA Astrophysics Data System (ADS)

    Nakata, Takashi; Otsuki, Kenshiro; Khan, S. H.

    1990-09-01

    The active faults of the Himalayas and neighboring areas are direct indicators of Recent and sub-Recent crustal movements due to continental collision between the Indian and Eurasian plates. The direction of the maximum horizontal shortening or horizontal compressive stress axes deduced from the strike and type of active faulting reveals a characteristic regional stress field along the colliding boundary. The trajectories of the stress axes along the transcurrent faults and the Eastern Himalayan Front, are approximately N-S, parallel to the relative motion of the two plates. However, along the southern margin of the Eurasian plate, they are NE-SW in the Western Himalayan Front and NW-SE to E-W in the Kirthar-Sulaiman Front, which is not consistent with the direction of relative plate motion. A simple model is proposed in order to explain the regional stress pattern. In this model, the tectonic sliver between the transcurrent faults and the plate margin, is dragged northward by the oblique convergence of the Indian plate. Thus, the direction of relative motion between the tectonic sliver and the Indian plate changes regionally, causing local compressive stress fields. Judging from the long-term slip rates along the active faults, the relative motion between the Indian and Eurasian plates absorbed in the colliding zone is about one fourth of its total amount; the rest may be consumed along the extensive strike-slip faults in Tibet and China.

  11. The Potsdam plates of the Carte du Ciel project: I. Present inventory and plate catalogue

    NASA Astrophysics Data System (ADS)

    Tsvetkova, K.; Tsvetkov, M.; Böhm, P.; Steinmetz, M.; Dick, W. R.

    2009-10-01

    We present an inventory of the Carte du Ciel (CdC) plates stored in the Astrophysical Institute Potsdam. The Potsdam CdC zone (+32° to +39°) was divided into 1232 areas and about 2200 plates from the first and second epochs were obtained within the framework of the CdC project. At present, only 977 plates (45% of all) are stored in AIP, the others got lost during the Second World War. The plates for the first epoch measurements had been obtained during the period 1893 May-1900 February. The plates for the second epoch (1913 August-1924 February) can be separated into two time intervals according to the observer and the observing method used: from 1913 August till 1914 July, and from 1916 February to 1924 February. The present work aims to provide online access to the plate information, given in the plate catalogue and is the first step to online access to the plate images digitized with flatbed scanners.

  12. Lasting mantle scars lead to perennial plate tectonics

    NASA Astrophysics Data System (ADS)

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-06-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a `perennial' phenomenon.

  13. Lasting mantle scars lead to perennial plate tectonics

    PubMed Central

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a ‘perennial' phenomenon. PMID:27282541

  14. Lasting mantle scars lead to perennial plate tectonics.

    PubMed

    Heron, Philip J; Pysklywec, Russell N; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a 'perennial' phenomenon. PMID:27282541

  15. Lasting mantle scars lead to perennial plate tectonics.

    PubMed

    Heron, Philip J; Pysklywec, Russell N; Stephenson, Randell

    2016-06-10

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a 'perennial' phenomenon.

  16. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor.

    PubMed

    Chen, Pin-Chuan; Park, Daniel S; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A; Nikitopoulos, Dimitris E; Murphy, Michael C

    2010-08-01

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date.

  17. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor

    PubMed Central

    Chen, Pin-Chuan; Park, Daniel S.; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A.; Nikitopoulos, Dimitris E.; Murphy, Michael C.

    2010-01-01

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date. PMID:20871807

  18. Performance evaluation of the R6R018 fuel plate using PLATE code

    SciTech Connect

    Pavel G. Medvedev; Hakan Ozaltun

    2010-03-01

    The paper presents results of performance evaluation of the R6R018 fuel plate using PLATE code. R6R018 is a U-7Mo dispersion type mini-plate with Al-3.5Si matrix irradiated in the RERTR-9B experiment. The design of this plate is prototypical of the planned LEONIDAS irradiation test. Therefore, a detailed performance analysis of this plate is important to confirm acceptable behavior in pile, and to provide baseline and justification for further analysis and testing. Specific results presented in the paper include fuel temperature history, growth of the interaction layer between the U-Mo and the matrix, swelling, growth of the corrosion layer, and degradation of thermal conductivity. The methodology of the analysis will be discussed including the newly developed capability to account for the formation of the interaction layer during fuel fabrication.

  19. Plate on plate osteosynthesis for the treatment of nonhealed periplate fractures.

    PubMed

    Arealis, Georgios; Nikolaou, Vassilios S; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation.

  20. Nonlocal third-order shear deformation plate theory with application to bending and vibration of plates

    NASA Astrophysics Data System (ADS)

    Aghababaei, Ramin; Reddy, J. N.

    2009-09-01

    The third-order shear deformation plate theory of Reddy [A simple higher-order theory for laminated composite plates, J. Appl. Mech. 51 (1984) 745-752] is reformulated using the nonlocal linear elasticity theory of Eringen. This theory has ability to capture the both small scale effects and quadratic variation of shear strain and consequently shear stress through the plate thickness. Analytical solutions of bending and free vibration of a simply supported rectangular plate are presented using this theory to illustrate the effect of nonlocal theory on deflection and natural frequency of the plates. Finally, the relations between nonlocal third-order, first-order and classical theories are discussed by numerical results.

  1. Highly conductive composites for fuel cell flow field plates and bipolar plates

    DOEpatents

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  2. Plate on Plate Osteosynthesis for the Treatment of Nonhealed Periplate Fractures

    PubMed Central

    Nikolaou, Vassilios S.; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation. PMID:24967127

  3. Microporous microchannel plates and method of manufacturing same

    SciTech Connect

    Beetz, C.P. Jr.; Boerstler, R.W.; Steinbeck, J.; Winn, D.R.

    2000-04-04

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  4. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  5. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate......

  6. Free vibrations of laminated composite elliptic plates

    NASA Technical Reports Server (NTRS)

    Andersen, C. M.; Noor, A. K.

    1976-01-01

    The free vibrations are studied of laminated anisotropic elliptic plates with clamped edges. The analytical formulation is based on a Mindlin-Reissner type plate theory with the effects of transverse shear deformation, rotary inertia, and bending-extensional coupling included. The frequencies and mode shapes are obtained by using the Rayleigh-Ritz technique in conjunction with Hamilton's principle. A computerized symbolic integration approach is used to develop analytic expressions for the stiffness and mass coefficients and is shown to be particularly useful in evaluating the derivatives of the eigenvalues with respect to certain geometric and material parameters. Numerical results are presented for the case of angle-ply composite plates with skew-symmetric lamination.

  7. Stamping and wrinkling of elastic plates.

    PubMed

    Hure, Jérémy; Roman, Benoît; Bico, José

    2012-08-01

    We study the peculiar wrinkling pattern of an elastic plate stamped into a spherical mold. We show that the wavelength of the wrinkles decreases with their amplitude, but reaches a minimum when the amplitude is of the order of the thickness of the plate. The force required for compressing the wrinkled plate presents a maximum independent of the thickness. A model is derived and verified experimentally for a simple one-dimensional case. This model is extended to the initial situation through an effective Young modulus representing the mechanical behavior of the wrinkled state. The theoretical predictions are shown to be in good agreement with the experiments. This approach provides a complement to the "tension field theory" developed for wrinkles with unconstrained amplitude.

  8. Drag Measurements of Porous Plate Acoustic Liners

    NASA Technical Reports Server (NTRS)

    Wolter, John D.

    2005-01-01

    This paper presents the results of direct drag measurements on a variety of porous plate acoustic liners. The existing literature describes numerous studies of drag on porous walls with injection or suction, but relatively few of drag on porous plates with neither injection nor suction. Furthermore, the porosity of the porous plate in existing studies is much lower than typically used in acoustic liners. In the present work, the acoustic liners consisted of a perforated face sheet covering a bulk acoustic absorber material. Factors that were varied in the experiment were hole diameter, hole pattern, face sheet thickness, bulk material type, and size of the gap (if any) between the face sheet and the absorber material.

  9. Caribbean tectonics and relative plate motions

    NASA Technical Reports Server (NTRS)

    Burke, K.; Dewey, J. F.; Cooper, C.; Mann, P.; Pindell, J. L.

    1984-01-01

    During the last century, three different ways of interpreting the tectonic evolution of the Gulf of Mexico and the Caribbean have been proposed, taking into account the Bailey Willis School of a permanent pre-Jurassic deep sea basin, the Edward Suess School of a subsided continental terrain, and the Alfred Wegener School of continental separation. The present investigation is concerned with an outline of an interpretation which follows that of Pindell and Dewey (1982). An attempt is made to point out ways in which the advanced hypotheses can be tested. The fit of Africa, North America, and South America is considered along with aspects of relative motion between North and South America since the early Jurasic. Attention is given to a framework for reconstructing Caribbean plate evolution, the evolution of the Caribbean, the plate boundary zones of the northern and southern Caribbean, and the active deformation of the Caribbean plate.

  10. Numerical modelling of instantaneous plate tectonics

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Haines, E.; Jordan, T. H.; Molnar, P.

    1974-01-01

    Assuming lithospheric plates to be rigid, 68 spreading rates, 62 fracture zones trends, and 106 earthquake slip vectors are systematically inverted to obtain a self-consistent model of instantaneous relative motions for eleven major plates. The inverse problem is linearized and solved iteratively by a maximum-likelihood procedure. Because the uncertainties in the data are small, Gaussian statistics are shown to be adequate. The use of a linear theory permits (1) the calculation of the uncertainties in the various angular velocity vectors caused by uncertainties in the data, and (2) quantitative examination of the distribution of information within the data set. The existence of a self-consistent model satisfying all the data is strong justification of the rigid plate assumption. Slow movement between North and South America is shown to be resolvable.

  11. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  12. Dual fuel gradients in uranium silicide plates

    SciTech Connect

    Pace, B.W.

    1997-08-01

    Babcock & Wilcox has been able to achieve dual gradient plates with good repeatability in small lots of U{sub 3}Si{sub 2} plates. Improvements in homogeneity and other processing parameters and techniques have allowed the development of contoured fuel within the cladding. The most difficult obstacles to overcome have been the ability to evaluate the bidirectional fuel loadings in comparison to the perfect loading model and the different methods of instilling the gradients in the early compact stage. The overriding conclusion is that to control the contour of the fuel, a known relationship between the compact, the frames and final core gradient must exist. Therefore, further development in the creation and control of dual gradients in fuel plates will involve arriving at a plausible gradient requirement and building the correct model between the compact configuration and the final contoured loading requirements.

  13. Hydrogen Embrittlement of Pulse-Plated Nickel

    NASA Astrophysics Data System (ADS)

    Reese, Eggert D.; Von Bestenbostel, Wolfgang; Sebald, Torsten; Paronis, Georgios; Vanelli, Diego; Müller, Yves

    2014-08-01

    The objective of the European-funded project MultiHy (Multiscale modeling of hydrogen embrittlement in crystalline materials) is the development of multiscale models for hydrogen transport in complex microstructures. The validation and application of the models will be carried out by investigating the role of the microstructure in industrial problems involving hydrogen embrittlement (HE) of advanced materials. Pulse-plated nickel (PP-Ni) material, as used in various industrial applications, has shown a susceptibility to HE that may cause premature failure of a structure. Due to the nature of the pulse-plating process, H is incorporated into the microstructure of the material. This H may lead to crack initiation when combined with localized stress concentrations due to subsequent manufacturing steps, e.g., welding. This article provides an overview of experimental studies aimed at evaluating the influence of the microstructure on the susceptibility of PP-Ni to HE and, ultimately, at improving the plating process.

  14. Astrometric properties of the Tautenburg Plate Scanner

    NASA Astrophysics Data System (ADS)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  15. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-05-06

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  16. Plate tectonics drive tropical reef biodiversity dynamics

    PubMed Central

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  17. Retardation Measurements of Infrared PVA Wave plate

    NASA Astrophysics Data System (ADS)

    Sun, Y.; Z, H.; W, D.; D, Y.; Z, Z.; S, J.

    The wave plate made of Polyvinyl Alcohol PVA plastic film has several advantages such as its lower cost and insensitivity to temperature and incidence angle so it has been used in the Solar Multi-Channel Telescope SMCT in China But the important parameter retardations of PVA wave plates in the near infrared wavelength have never been provided In this paper a convenient and high precise instrument to get the retardations of discrete wavelengths or a continuous function of wavelength in near infrared is developed In this method the retardations of wave plates have been determined through calculating the maximum and minimum of light intensity The instrument error has been shown Additionally we can get the continuous direction of wavelength retardations in the ultraviolet visible or infrared spectral in another way

  18. Plate tectonics drive tropical reef biodiversity dynamics

    NASA Astrophysics Data System (ADS)

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-05-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  19. Composite plates impact damage - An atlas

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1991-01-01

    The present volume on impact damage in composite plates presents an extensive compendium of visual and graphic data regarding a variety of material and impactor parameters. The photographs are taken with X-ray and C-scan imaging in conjunction with a dye penetrant to show matrix cracks and delaminations. Impact and static-loading tests are performed on plates of graphite-epoxy, graphite-toughened epoxy, and graphite-PEEK materials. The images are presented to yield specific visual data regarding such parameters as impactor velocity, thickness of the back ply group, impactor nose radius, and the effects of multiple delaminations. The images are grouped in eight subsets that correspond to parameters including plate length, material, and the difference in fiber orientation between adjacent ply groups. This substantial volume represents a systematic effort to study the effects of several material parameters on impact damage.

  20. Aerodynamic drag reduction by vertical splitter plates

    NASA Astrophysics Data System (ADS)

    Gilliéron, Patrick; Kourta, Azeddine

    2010-01-01

    The capacity of vertical splitter plates placed at the front or the rear of a simplified car geometry to reduce drag, with and without skew angle, is investigated for Reynolds numbers between 1.0 × 106 and 1.6 × 106. The geometry used is a simplified geometry to represent estate-type vehicles, for the rear section, and MPV-type vehicle. Drag reductions of nearly 28% were obtained for a zero skew angle with splitter plates placed at the front of models of MPV or utility vehicles. The results demonstrate the advantage of adapting the position and orientation of the splitter plates in the presence of a lateral wind. All these results confirm the advantage of this type of solution, and suggest that this expertise should be used in the automotive field to reduce consumption and improve dynamic stability of road vehicles.

  1. Impact resistance of composite laminated sandwich plates

    NASA Astrophysics Data System (ADS)

    Kim, Chun-Gon; Jun, Eui-Jin

    1992-01-01

    Investigated are the effects of face layup sequence and core density of a sandwich plate on the impact delamination area of the laminated facesheet. The sandwich plate is made of graphite/epoxy faces and Nomex honeycomb core. The size and shape of delamination due to impact at each interply location have been measured by the room temperature deply technique. The shape of the interply delamination under impact is, in general, found to be two-lobed. The shape exhibits very peculiar regularity under various experimental conditions. The quantitative measurement of delamination size has shown that the face layup with small relative orientation between adjacent plies and high density core are desirable in sandwich plates to reduce the impact delamination.

  2. Viscoelastic deformation near active plate boundaries

    NASA Technical Reports Server (NTRS)

    Ward, S. N.

    1986-01-01

    Model deformations near the active plate boundaries of Western North America using space-based geodetic measurements as constraints are discussed. The first six months of this project were spent gaining familarity with space-based measurements, accessing the Crustal Dynamics Data Information Computer, and building time independent deformation models. The initial goal was to see how well the simplest elastic models can reproduce very long base interferometry (VLBI) baseline data. From the Crustal Dynamics Data Information Service, a total of 18 VLBI baselines are available which have been surveyed on four or more occasions. These data were fed into weighted and unweighted inversions to obtain baseline closure rates. Four of the better quality lines are illustrated. The deformation model assumes that the observed baseline rates result from a combination of rigid plate tectonic motions plus a component resulting from elastic strain build up due to a failure of the plate boundary to slip at the full plate tectonic rate. The elastic deformation resulting from the locked plate boundary is meant to portray interseismic strain accumulation. During and shortly after a large interplate earthquake, these strains are largely released, and points near the fault which were previously retarded suddenly catch up to the positions predicted by rigid plate models. Researchers judge the quality of fit by the sum squares of weighted residuals, termed total variance. The observed baseline closures have a total variance of 99 (cm/y)squared. When the RM2 velocities are assumed to model the data, the total variance increases to 154 (cm/y)squared.

  3. A MEMS square Chladni plate resonator

    NASA Astrophysics Data System (ADS)

    Pala, Sedat; Azgın, Kıvanç

    2016-10-01

    This paper presents the design, fabrication and tests of a micro-fabricated MEMS ‘Chladni’ plate resonator. The proposed MEMS resonator has a square plate geometry having a side length of 1400 µm and a height of 35 µm. Its geometry and electrode layout are designed to analyze and test as many modes as possible. The MEMS plate is fabricated using a silicon-on-insulator process with a 35 µm thick < \\text{1} \\text{1} \\text{1}> silicon layer on a glass substrate. Transverse vibration of the plate is investigated to obtain closed form natural frequencies and mode shapes, which are derived using the Rayleigh-Ritz energy method, with an electrostatic softening effect included. Closed form equations for the calculation of effective stiffness’, masses and natural frequencies of the two modes (mode (1,1) and mode (2,0)-(0,2)) are presented, with and without electrostatic softening. The analytical model is verified for those modes by finite-element simulations, frequency response tests in vacuum and laser Doppler vibrometer (LDV) experiments. The derived model deviates from the finite-element analysis by 3.35% for mode (1,1) and 6.15% for mode (2,0)-(0,2). For verification, the frequency responses of the plates are measured with both electrostatic excitation-detection at around 20 mTorr vacuum ambient and LDV at around 0.364 mTorr vacuum ambient. The resonance frequency and Q-factor of mode (1,1) are measured to be 104.2 kHz and 14 300, respectively. For mode (2,0)-(0,2), the measured resonance frequency and Q-factor are 156.68 kHz and 10 700, respectively. The presented LDV results also support both natural frequencies of interest and corresponding mode shapes of the plate structure.

  4. Relationship between plume and plate tectonics

    NASA Astrophysics Data System (ADS)

    Puchkov, V. N.

    2016-07-01

    The relationship between plate- and plume-tectonics is considered in view of the growth and breakdown of supercontinents, active rifting, the formation of passive volcanic-type continental margins, and the origin of time-progressive volcanic chains on oceanic and continental plates. The mantle wind phenomenon is described, as well as its effect on plume morphology and anisotropy of the ambient mantle. The interaction of plumes and mid-ocean ridges is discussed. The principles and problems of plume activity analysis in subduction- and collision-related foldbelts are considered and illustrated with examples.

  5. Tomography, the geoid and plate motions

    SciTech Connect

    Gable, C.W.; O'connell, R.J. )

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period. 248 refs.

  6. Acquired plate-like osteoma cutis.

    PubMed

    Vashi, Neelam; Chu, Julie; Patel, Rishi

    2011-10-15

    Plate-like osteoma cutis is a rare disorder that has been historically classified as a congenital syndrome. It has a possible relationship to a mutation in the gene (GNAS1) that encodes the α-subunit of the stimulatory G protein, which regulates adenyl cyclase activity. We report a case of extensive plaque-like masses on the scalp and face with no abnormalities in calcium or phosphate metabolism and no preceding inflammatory cutaneous conditions. With less than ten reported cases, to our knowledge, this is one the few cases of acquired plate-like osteoma cutis described in the literature.

  7. PC-based car license plate reader

    NASA Astrophysics Data System (ADS)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  8. Imaging plates calibration to X-rays

    NASA Astrophysics Data System (ADS)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  9. Plating of open pediatric tibia fractures.

    PubMed

    Head, James; Lewis, T R; Puffinbarger, William; Garbrecht, Erika

    2014-07-01

    This study is a single center retrospective chart and radiographic review of patients with open tibia fractures under the age of 16 years of age over past 10 years. The purpose of this study is to investigate the treatment of open pediatric tibia fractures with plating in regards to time to ambulation, time to union, and deformity in comparison to other treatment options. We found that plating open pediatric tibia fractures is a safe treatment option that can lead to excellent results with low risk of complications. PMID:25223152

  10. Composite Thue-Morse zone plates.

    PubMed

    Ma, Wenzhuo; Tao, Shaohua; Cheng, Shubo

    2016-06-13

    We present a new family of diffractive lenses, composite Thue-Morse zone plates (CTMZPs), formed by multiple orders of Thue-Morse zone plates (TMZPs). The typical structure of a CTMZP is a composite of two concentric TMZPs. The focusing properties of the CTMZPs with different parameters have been investigated both theoretically and experimentally. Compared with the TMZPs, the CTMZPs have higher performance in axial intensity and imaging resolution. The CTMZP beams are also found to possess the self-reconstruction property, and would be useful for three-dimensional optical tweezers, laser machining, and optical imaging. PMID:27410293

  11. Seismology: tectonic strain in plate interiors?

    PubMed

    Calais, E; Mattioli, G; DeMets, C; Nocquet, J-M; Stein, S; Newman, A; Rydelek, P

    2005-12-15

    It is not fully understood how or why the inner areas of tectonic plates deform, leading to large, although infrequent, earthquakes. Smalley et al. offer a potential breakthrough by suggesting that surface deformation in the central United States accumulates at rates comparable to those across plate boundaries. However, we find no statistically significant deformation in three independent analyses of the data set used by Smalley et al., and conclude therefore that only the upper bounds of magnitude and repeat time for large earthquakes can be inferred at present.

  12. Finite stretching of an annular plate.

    NASA Technical Reports Server (NTRS)

    Biricikoglu, V.; Kalnins, A.

    1971-01-01

    The problem of the finite stretching of an annular plate which is bonded to a rigid inclusion at its inner edge is considered. The material is assumed to be isotropic and incompressible with a Mooney-type constitutive law. It is shown that the inclusion of the effect of the transverse normal strain leads to a rapid variation in thickness which is confined to a narrow edge zone. The explicit solutions to the boundary layer equations, which govern the behavior of the plate near the edges, are presented.

  13. Seismology: tectonic strain in plate interiors?

    PubMed

    Calais, E; Mattioli, G; DeMets, C; Nocquet, J-M; Stein, S; Newman, A; Rydelek, P

    2005-12-15

    It is not fully understood how or why the inner areas of tectonic plates deform, leading to large, although infrequent, earthquakes. Smalley et al. offer a potential breakthrough by suggesting that surface deformation in the central United States accumulates at rates comparable to those across plate boundaries. However, we find no statistically significant deformation in three independent analyses of the data set used by Smalley et al., and conclude therefore that only the upper bounds of magnitude and repeat time for large earthquakes can be inferred at present. PMID:16355163

  14. Simulating radiographic inspections with imaging plates

    NASA Astrophysics Data System (ADS)

    Yao, Min; Duvauchelle, Philippe; Kaftandjian, Valérie; Petersol-Parmentier, Angéla; Schumm, Andreas

    2016-02-01

    Computed Radiography (CR) based on photostimulable imaging plates (IP) is a potential replacement technique for traditional silver film radiography. For the inspections of components with high wall thicknesses requiring higher energy sources, however, imaging plate performance suffers from a spectral response which is low for the higher energies and high in the energy range where scattered radiation is typically observed. For these applications, care must be taken to apply appropriate filtering. Simulation tools are expected to be helpful in determining optimal operating conditions. We present a computer model which combines deterministic and Monte Carlo methods to simulate the imaging chain, focusing in particular on the scanner model.

  15. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W.

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  16. Transient vibration of thin viscoelastic orthotropic plates

    NASA Astrophysics Data System (ADS)

    Soukup, J.; Valeš, F.; Volek, J.; Skočilas, J.

    2011-02-01

    This article deals with solutions of transient vibration of a rectangular viscoelastic orthotropic thin 2D plate for particular deformation models according to Flügge and Timoshenko-Mindlin. The linear model, a general standard viscoelastic body, of the rheologic properties of a viscoelastic material was applied. The time and coordinate curves of the basic quantities displacement, rotation, velocity, stress and deformation are compared. The results obtained by an approximate analytic method are compared with numerical results for 3D plate generated by FEM application and with experimental investigation.

  17. Moire interferometry for vibration analysis of plates

    NASA Astrophysics Data System (ADS)

    Asundi, A.; Cheung, M. T.

    1987-12-01

    Moire interferometry is used to locate nodal regions and measure vibration amplitudes of sinusoidally vibrating square plates. The high sensitivity afforded by this technique makes possible the study of plate vibrations at high frequencies and low amplitudes. The initial pattern is modulated by the zero-order Bessel function representing the vibratory motion. The fringe (or fringes) with best contrast indicate the nodal regions, while the higher order fringes, describing loci of points vibrating with the same amplitude, have decreasing contrast which is improved by spatial filtering.

  18. The stepped hybrid plate for carpal panarthrodesis - Part I: relationship between plate and bone surfaces.

    PubMed

    Diaz-Bertrana, C; Darnaculleta, F; Durall, I; Franch, J; Puchol, J L

    2009-01-01

    In the 1990s, the AO (Arbeitsgemeinschaft für Osteosynthesefragen) Hand Study Group developed several anatomically bent plates (standard and short) for wrist panarthrodesis in humans. However, only straight plates have been used for carpal panarthrodesis (CP) in animals to date. The primary purpose of this study was to determine if precontoured plates are more anatomical for CP in dogs. Measurement of several of the bones that are implicated in CP, as well as the relationship between their surfaces and the surface of a straight plate, were performed in a radiographic and computed tomographic cadaveric study. Axial and transverse measurements taken at different levels of the metacarpal bones 2, 3 and 4 were also included. The second objective of this study was to develop a more anatomical CP plate according to the results obtained. The measurements and images obtained in this study show that, as in human orthopaedics, bent or stepped plates are more anatomically correct than straight plates for CP in dogs.

  19. Actively controlling coolant-cooled cold plate configuration

    DOEpatents

    Chainer, Timothy J.; Parida, Pritish R.

    2016-04-26

    Cooling apparatuses are provided to facilitate active control of thermal and fluid dynamic performance of a coolant-cooled cold plate. The cooling apparatus includes the cold plate and a controller. The cold plate couples to one or more electronic components to be cooled, and includes an adjustable physical configuration. The controller dynamically varies the adjustable physical configuration of the cold plate based on a monitored variable associated with the cold plate or the electronic component(s) being cooled by the cold plate. By dynamically varying the physical configuration, the thermal and fluid dynamic performance of the cold plate are adjusted to, for example, optimally cool the electronic component(s), and at the same time, reduce cooling power consumption used in cooling the electronic component(s). The physical configuration can be adjusted by providing one or more adjustable plates within the cold plate, the positioning of which may be adjusted based on the monitored variable.

  20. How to optimize the drop plate method for enumerating bacteria.

    PubMed

    Herigstad, B; Hamilton, M; Heersink, J

    2001-03-01

    The drop plate (DP) method can be used to determine the number of viable suspended bacteria in a known beaker volume. The drop plate method has some advantages over the spread plate (SP) method. Less time and effort are required to dispense the drops onto an agar plate than to spread an equivalent total sample volume into the agar. By distributing the sample in drops, colony counting can be done faster and perhaps more accurately. Even though it has been present in the laboratory for many years, the drop plate method has not been standardized. Some technicians use 10-fold dilutions, others use twofold. Some technicians plate a total volume of 0.1 ml, others plate 0.2 ml. The optimal combination of such factors would be useful to know when performing the drop plate method. This investigation was conducted to determine (i) the standard deviation of the bacterial density estimate, (ii) the cost of performing the drop plate procedure, (iii) the optimal drop plate design, and (iv) the advantages of the drop plate method in comparison to the standard spread plate method. The optimal design is the combination of factor settings that achieves the smallest standard deviation for a fixed cost. Computer simulation techniques and regression analysis were used to express the standard deviation as a function of the beaker volume, dilution factor, and volume plated. The standard deviation expression is also applicable to the spread plate method.

  1. Plate-induced Miocene extension in southern California

    SciTech Connect

    Stuart, W.D. Univ. of California, Santa Barbara, CA )

    1992-01-01

    Miocene crustal extension in southern California can be explained by the interaction of tectonic plates in relative motion. The Pacific, Juan de Fuca, and Farallon (Guadalupe) plates are represented by flat elastic plates surrounded by an infinite elastic plate, the eastern part of which represents the North America plate. Forcing is by assigned subduction pull, and tractions at all plate boundaries satisfy a viscous constitutive law. Plate bottoms are stress-free. In the first part of the solution plate velocities and boundary tractions are found from static equilibrium. Then principal horizontal stresses and strains in plate interiors caused by tractions and subduction pull are found by a boundary element procedure. Using plate boundary geometry from Stock and Hodges for early- and mid-Miocene times, it is found that the portion of the North America plate margin between the Mendocino and Rivera triple junctions has maximum extensional strain directed westward. This result is generally consistent with directions associated with metamorphic core complex formation in southern California. The model is also consistent with extensional strain and rotation sense of crustal blocks in the vicinity of Los Angeles, as inferred by Luyendyk and others from paleomagnetic data. In the model the greatest extensional strain of the North America plate occurs near the Pacific-North America transform, in the area above the absent Farallon slab. Extension direction varies from northwest to southwest according to plate geometry, subduction pull (Juan de Fuca and Guadalupe), and plate boundary tractions.

  2. Mechanical properties of Indonesian-made narrow dynamic compression plate.

    PubMed

    Dewo, P; van der Houwen, E B; Sharma, P K; Magetsari, R; Bor, T C; Vargas-Llona, L D; van Horn, J R; Busscher, H J; Verkerke, G J

    2012-09-01

    Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates the utilisation of local products. In this paper, we investigated the mechanical properties, i.e. proportional limit and fatigue strength of Indonesian-made Narrow Dynamic Compression Plates (Narrow DCP) as one of the most frequently used osteosynthesis plates, in comparison to the European AO standard plate, and its relationship to geometry, micro structural features and surface defects of the plates. All Indonesian-made plates appeared to be weaker than the standard Narrow DCP because they consistently failed at lower stresses. Surface defects did not play a major role in this, although the polishing of the Indonesian Narrow DCP was found to be poor. The standard plate showed indications of cold deformation from the production process in contrast to the Indonesian plates, which might be the first reason for the differences in strength. This is confirmed by hardness measurements. A second reason could be the use of an inferior version of stainless steel. The Indonesian plates showed lower mechanical behaviour compared to the AO-plates. These findings could initiate the development of improved Indonesian manufactured DCP-plates with properties comparable to commonly used plates, such as the standard European AO-plates.

  3. Treatment of middle-third clavicle fractures using anterior plating with a dynamic compression plate (DCP).

    PubMed

    Subramanian, Padmanabhan; Joshi, Meera; Shilston, Sophie; Wallace, Donald; Pearce, Oliver J

    2013-03-01

    Significantly displaced midshaft clavicle fractures can be managed operatively to restore anatomy and allow early mobilization. Several techniques have described using precontoured anatomically designed plates placed on the superior surface of the bone or reconstruction plates contoured by the surgeon placed either superiorly or anteriorly. We describe the use of the dynamic compression plate placed anteriorly on the clavicle in treating these fractures and discuss the relative advantages of this technique. We have a case series of 8 patients over a 2-year period, who were followed up and all went on to successful fracture union.

  4. A New Test of Plate Tectonics.

    ERIC Educational Resources Information Center

    Shea, James Herbert

    1989-01-01

    Discussed are two techniques that can be used to directly test the theory that the plates which make up the crust of the earth are still moving. Described are the use of satellite laser ranging and very long baseline interferometry. Samples of data and their analysis are provided. (CW)

  5. 30 CFR 33.11 - Approval plates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES General Provisions... unit, conditions of approval, and identifying numbers of the dust-collector parts. When deemed... plate shall not impair the dust-collection or explosion-proof features of the unit. (d) The...

  6. Static in situ calibration of force plates.

    PubMed

    Hall, M G; Fleming, H E; Dolan, M J; Millbank, S F; Paul, J P

    1996-05-01

    An in situ calibration protocol for ground-to-foot force measuring platforms is described. The methodology allows verification of the function of the force plate and allows accurate calibration for three force and moment channels. The effect of cross-sensitivity on recorded data is discussed along with the need for improvements in methodology to quantify this property.

  7. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... (f) Reference to the roof load zone and wind load zone for which the home is designed and duplicates... certificate and insulation zone map required by §§ 3280.510 and 3280.511. The Wind Zone Map on the Data Plate shall also contain the statement: This home has not been designed for the higher wind pressures...

  8. Brazed bipolar plates for PEM fuel cells

    DOEpatents

    Neutzler, Jay Kevin

    1998-01-01

    A liquid-cooled, bipolar plate separating adjacent cells of a PEM fuel cell comprising corrosion-resistant metal sheets brazed together so as to provide a passage between the sheets through which a dielectric coolant flows. The brazement comprises a metal which is substantially insoluble in the coolant.

  9. Brazed bipolar plates for PEM fuel cells

    DOEpatents

    Neutzler, J.K.

    1998-07-07

    A liquid-cooled, bipolar plate separating adjacent cells of a PEM fuel cell comprises corrosion-resistant metal sheets brazed together so as to provide a passage between the sheets through which a dielectric coolant flows. The brazement comprises a metal which is substantially insoluble in the coolant. 6 figs.

  10. Quantitative tests for plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Kaula, W. M.; Phillips, R. J.

    1981-01-01

    Quantitative comparisons are made between the characteristics of plate tectonics on the earth and those which are possible on Venus. Considerations of the factors influencing rise height and relating the decrease in rise height to plate velocity indicate that the rate of topographic dropoff from spreading centers should be about half that on earth due to greater rock-fluid density contrast and lower temperature differential between the surface and interior. Statistical analyses of Pioneer Venus radar altimetry data and global earth elevation data is used to identify 21,000 km of ridge on Venus and 33,000 km on earth, and reveal Venus ridges to have a less well-defined mode in crest heights and a greater concavity than earth ridges. Comparison of the Venus results with the spreading rates and associated heat flow on earth reveals plate creation rates on Venus to be 0.7 sq km/year or less and indicates that not more than 15% of Venus's energy is delivered to the surface by plate tectonics, in contrast to values of 2.9 sq km a year and 70% for earth.

  11. Ultralight shape-recovering plate mechanical metamaterials.

    PubMed

    Davami, Keivan; Zhao, Lin; Lu, Eric; Cortes, John; Lin, Chen; Lilley, Drew E; Purohit, Prashant K; Bargatin, Igor

    2015-12-03

    Unusual mechanical properties of mechanical metamaterials are determined by their carefully designed and tightly controlled geometry at the macro- or nanoscale. We introduce a class of nanoscale mechanical metamaterials created by forming continuous corrugated plates out of ultrathin films. Using a periodic three-dimensional architecture characteristic of mechanical metamaterials, we fabricate free-standing plates up to 2 cm in size out of aluminium oxide films as thin as 25 nm. The plates are formed by atomic layer deposition of ultrathin alumina films on a lithographically patterned silicon wafer, followed by complete removal of the silicon substrate. Unlike unpatterned ultrathin films, which tend to warp or even roll up because of residual stress gradients, our plate metamaterials can be engineered to be extremely flat. They weigh as little as 0.1 g cm(-2) and have the ability to 'pop-back' to their original shape without damage even after undergoing multiple sharp bends of more than 90°.

  12. Micro-channel plates and vacuum detectors

    NASA Astrophysics Data System (ADS)

    Gys, T.

    2015-07-01

    A micro-channel plate is an array of miniature electron multipliers that are each acting as a continuous dynode chain. The compact channel structure results in high spatial and time resolutions and robustness to magnetic fields. Micro-channel plates have been originally developed for night vision applications and integrated as an amplification element in image intensifiers. These devices show single-photon sensitivity with very low noise and have been used as such for scintillating fiber tracker readout in high-energy physics experiments. Given their very short transit time spread, micro-channel plate photomultiplier tubes are also being used in time-of-flight and particle identification detectors. The present paper will cover the history of the micro-channel plate development, basic features, and some of their applications. Emphasis will be put on various new manufacturing processes that have been developed over the last few years, and that result in a significant improvement in terms of efficiency, noise, and lifetime performance.

  13. 30 CFR 33.11 - Approval plates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Approval plates. 33.11 Section 33.11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES General...

  14. 30 CFR 33.11 - Approval plates.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Approval plates. 33.11 Section 33.11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES General...

  15. 30 CFR 33.11 - Approval plates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approval plates. 33.11 Section 33.11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES General...

  16. A swirl flow evaporative cold plate

    NASA Technical Reports Server (NTRS)

    Niggemann, R. E.; Greenlee, W. J.; Hill, D. G.; Ellis, W.; Marshall, P.

    1985-01-01

    A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

  17. Copyboard Quickly Makes Clean Printing Plates

    NASA Technical Reports Server (NTRS)

    Balandis, W. D.

    1985-01-01

    Vacuum-chuck eliminates glass and sponge artwork support. Vacuum copyboard allows camera-ready original slid on top plate for proper positioning, then holds securely for photography. Bleed valve allows vacuum in copyboard box adjusted for small or large originals. With new copyboard, time-consuming and costly procedures unnecessary.

  18. BEPLATE emdash simulation of electrochemical plating

    SciTech Connect

    Giles, G.E. ); Gray, L.J. ); Bullock, J.S. IV )

    1990-09-01

    BEPLATE is a FORTRAN code that uses the boundary element method to simulate the electrochemical plating of material on parts, primarily rotating axisymmetric parts. A boundary element technique is used to solve for the local current density and thus the plating rate on the part, which is used to calculate the growth in the plated layer over a user-specified time step. The surface is moved to reflect this growth, and the new surface is used to generate the local current density. This cycle is repeated until the final time specified by the analyst, producing the final plated thickness. BEPLATE includes models for the polarization effects at both the part (cathode) and anode and allows the use of symmetry planes and nonconducting shields. For electroplating simulations, the part shape is normally assumed to be axisymmetric with a centerline along the z-axis. More general part shapes can be analyzed by BEPLATE if the surface growth simulation is not needed. In either case, the shield, anode, and tank geometries are not restricted to specific shapes. This report includes the information required to run BEPLATE, specifically, a brief description of the BEPLATE system including hardware and software requirements, a description of the complete simulation process, discussion of rules for generating models, and additional reference material. This system of codes consists of model generators (PIGS or PATRAN), input processor (BEPIN), the simulation code (BEPLATE) and postprocessing codes (PATRAN or CONPLOT).

  19. 19 CFR 115.42 - Approval plates.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... entry is not required in the space provided for type identifiers on an approval plate for containers... with the same specifications may be placed in such space. This may be used to assist in the... possible methods of accomplishing this are: (1) Placing an “X” in front of the numeric portion of...

  20. Magnetically excited flexural plate wave apparatus

    DOEpatents

    Martin, S.J.; Butler, M.A.; Frye, G.C.; Smith, J.H.

    1998-11-17

    A non-piezoelectric flexural plate wave apparatus having meander-line transducers mounted on a non-piezoelectric membrane is disclosed. A static magnetic field is directed perpendicularly to the conductive legs of the transducers in the plane of the membrane. Single-port, two-port, resonant, non-resonant, eigenmode, and delay-line modes may be employed. 15 figs.