Science.gov

Sample records for 3d gait analysis

  1. 3D finite element model of the diabetic neuropathic foot: a gait analysis driven approach.

    PubMed

    Guiotto, Annamaria; Sawacha, Zimi; Guarneri, Gabriella; Avogaro, Angelo; Cobelli, Claudio

    2014-09-22

    Diabetic foot is an invalidating complication of diabetes that can lead to foot ulcers. Three-dimensional (3D) finite element analysis (FEA) allows characterizing the loads developed in the different anatomical structures of the foot in dynamic conditions. The aim of this study was to develop a subject specific 3D foot FE model (FEM) of a diabetic neuropathic (DNS) and a healthy (HS) subject, whose subject specificity can be found in term of foot geometry and boundary conditions. Kinematics, kinetics and plantar pressure (PP) data were extracted from the gait analysis trials of the two subjects with this purpose. The FEM were developed segmenting bones, cartilage and skin from MRI and drawing a horizontal plate as ground support. Materials properties were adopted from previous literature. FE simulations were run with the kinematics and kinetics data of four different phases of the stance phase of gait (heel strike, loading response, midstance and push off). FEMs were then driven by group gait data of 10 neuropathic and 10 healthy subjects. Model validation focused on agreement between FEM-simulated and experimental PP. The peak values and the total distribution of the pressures were compared for this purpose. Results showed that the models were less robust when driven from group data and underestimated the PP in each foot subarea. In particular in the case of the neuropathic subject's model the mean errors between experimental and simulated data were around the 20% of the peak values. This knowledge is crucial in understanding the aetiology of diabetic foot.

  2. Combined robotic-aided gait training and 3D gait analysis provide objective treatment and assessment of gait in children and adolescents with Acquired Hemiplegia.

    PubMed

    Molteni, Erika; Beretta, Elena; Altomonte, Daniele; Formica, Francesca; Strazzer, Sandra

    2015-08-01

    To evaluate the feasibility of a fully objective rehabilitative and assessment process of the gait abilities in children suffering from Acquired Hemiplegia (AH), we studied the combined employment of robotic-aided gait training (RAGT) and 3D-Gait Analysis (GA). A group of 12 patients with AH underwent 20 sessions of RAGT in addition to traditional manual physical therapy (PT). All the patients were evaluated before and after the training by using the Gross Motor Function Measures (GMFM), the Functional Assessment Questionnaire (FAQ), and the 6 Minutes Walk Test. They also received GA before and after RAGT+PT. Finally, results were compared with those obtained from a control group of 3 AH children who underwent PT only. After the training, the GMFM and FAQ showed significant improvement in patients receiving RAGT+PT. GA highlighted significant improvement in stance symmetry and step length of the affected limb. Moreover, pelvic tilt increased, and hip kinematics on the sagittal plane revealed statistically significant increase in the range of motion during the hip flex-extension. Our data suggest that the combined program RAGT+PT induces improvements in functional activities and gait pattern in children with AH, and it demonstrates that the combined employment of RAGT and 3D-GA ensures a fully objective rehabilitative program.

  3. [3-D ultrasound-assisted gait analysis of schizophrenic patients. Comparison between conventional neuroleptics and olanzapine].

    PubMed

    Putzhammer, Albert; Heindl, Bernhard; Müller, Jürgen; Broll, Karin; Pfeiff, Liane; Perfahl, Maria; Hess, Linda; Koch, Horst

    2003-05-01

    Schizophrenic disorders as well as neuroleptic treatment can affect locomotion. The study assessed the influence of neuroleptic treatment on human gait via ultrasonic topometric gait analysis. In a control sample the test system proved high test-retest-reliability. Spatial and temporal gait parameters were assessed in schizophrenic patients without neuroleptic treatment (n = 12) and under treatment with conventional neuroleptics (n = 14) and re-assessed after treatment change to the atypical neuroleptic olanzapine in a repeated measures design. After switch from conventional neuroleptics to olanzapine patients showed an increase of gait velocity (p < or = 0.01) and step length (p < or = 0.01) whereas the cadence remained stable. Significant differences between the untreated state and treatment with olanzapine were not detectable. We conclude that bipedal gait is affected by conventional neuroleptic treatment. The degree of impairment can be objectively measured by testing spatio-temporal and kinematic gait parameters via three-dimensional ultrasonic gait analysis.

  4. Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis.

    PubMed

    Pfister, Alexandra; West, Alexandre M; Bronner, Shaw; Noah, Jack Adam

    2014-07-01

    Biomechanical analysis is a powerful tool in the evaluation of movement dysfunction in orthopaedic and neurologic populations. Three-dimensional (3D) motion capture systems are widely used, accurate systems, but are costly and not available in many clinical settings. The Microsoft Kinect™ has the potential to be used as an alternative low-cost motion analysis tool. The purpose of this study was to assess concurrent validity of the Kinect™ with Brekel Kinect software in comparison to Vicon Nexus during sagittal plane gait kinematics. Twenty healthy adults (nine male, 11 female) were tracked while walking and jogging at three velocities on a treadmill. Concurrent hip and knee peak flexion and extension and stride timing measurements were compared between Vicon and Kinect™. Although Kinect measurements were representative of normal gait, the Kinect™ generally under-estimated joint flexion and over-estimated extension. Kinect™ and Vicon hip angular displacement correlation was very low and error was large. Kinect™ knee measurements were somewhat better than hip, but were not consistent enough for clinical assessment. Correlation between Kinect™ and Vicon stride timing was high and error was fairly small. Variability in Kinect™ measurements was smallest at the slowest velocity. The Kinect™ has basic motion capture capabilities and with some minor adjustments will be an acceptable tool to measure stride timing, but sophisticated advances in software and hardware are necessary to improve Kinect™ sensitivity before it can be implemented for clinical use.

  5. Gait pattern in myotonic dystrophy (Steinert disease): a kinematic, kinetic and EMG evaluation using 3D gait analysis.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Crugnola, Veronica; Priano, Lorenzo; Menegoni, Francesco; Trotti, Claudio; Milano, Eva; Mauro, Alessandro

    2012-03-15

    We investigated the gait pattern of 10 patients with myotonic dystrophy (Steinert disease; 4 females, 6 males; age: 41.5+7.6 years), compared to 20 healthy controls, through manual muscle test and gait analysis, in terms of kinematic, kinetic and EMG data. In most of patients (80%) distal muscle groups were weaker than proximal ones. Weakness at lower limbs was in general moderate to severe and MRC values evidenced a significant correlation between tibialis anterior and gastrocnemius medialis (R=0.91). An overall observation of gait pattern in patients when compared to controls showed that most spatio-temporal parameters (velocity, step length and cadence) were significantly different. As concerns kinematics, patients' pelvic tilt was globally in a higher position than control group, with reduced hip extension ability in stance phase and limited range of motion; 60% of the limbs revealed knee hyperextension during midstance and ankle joints showed a quite physiological position at initial contact and higher dorsiflexion during stance phase if compared to healthy individuals. Kinetic plots evidenced higher hip power during loading response and lower ankle power generation in terminal stance. The main EMG abnormalities were seen in tibialis anterior and gastrocnemius medialis muscles. In this study gait analysis gives objective and quantitative information about the gait pattern and the deviations due to the muscular situation of these patients; these results are important from a clinical point of view and suggest that rehabilitation programs for them should take these findings into account.

  6. Gait Strategy in Patients with Ehlers-Danlos Syndrome Hypermobility Type: A Kinematic and Kinetic Evaluation Using 3D Gait Analysis

    ERIC Educational Resources Information Center

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Castori, Marco; Celletti, Claudia; Albertini, Giorgio; Camerota, Filippo

    2011-01-01

    The aim of this study was to quantify the gait patterns of adults with joint hypermobility syndrome/Ehlers-Danlos syndrome (JHS/EDS-HT) hypermobility type, using Gait Analysis. We quantified the gait strategy in 12 JHS/EDS-HT adults individuals (age: 43.08 + 6.78 years) compared to 20 healthy controls (age: 37.23 plus or minus 8.91 years), in…

  7. Gait analysis using 3D accelerometry in horses sedated with xylazine.

    PubMed

    López-Sanromán, F J; Holmbak-Petersen, R; Santiago, I; Gómez de Segura, I A; Barrey, E

    2012-07-01

    The aim of the present study was to verify the efficacy and sensitivity of an accelerometric device in detecting and quantifying the degree of movement alteration produced in horses sedated with xylazine. Horses (n=6) were randomly administered either xylazine or a control by intravenous injection, with at least 1 week between each treatment. A triaxial accelerometric device was used for the accelerometric gait assessment 15 min before (baseline) and 5, 15, 30, 45, 60, 75, 90, 105 and 120 min after each treatment. Eight different accelerometric parameters were calculated, including speed, stride frequency, stride length, regularity, dorsoventral power, propulsion power, mediolateral power and total power, with the force of acceleration and the dorsoventral, mediolateral and craniocaudal (propulsive) parts of the power then calculated. Administration of xylazine decreased many of the parameters investigated, with significant differences for speed, stride frequency, dorsoventral power, propulsion power and total power at 5, 15, 30 and 45 min after injection. There were no significant differences in stride length values at any time point. Decreases in regularity values were evident with significant differences at every time point from 5 to 120 min following xylazine injection. Force values were also significantly reduced from 5 to 30 min after treatment and a redistribution of the total power was observed 5 min after injection as the mediolateral power increased significantly, while the dorsoventral power decreased. Accelerometry offers a practical, accurate, easy to use, portable and low cost method of objectively monitoring gait abnormalities at the walk in horses after sedation with xylazine.

  8. Gait strategy in patients with Ehlers-Danlos syndrome hypermobility type: a kinematic and kinetic evaluation using 3D gait analysis.

    PubMed

    Galli, Manuela; Cimolin, Veronica; Rigoldi, Chiara; Castori, Marco; Celletti, Claudia; Albertini, Giorgio; Camerota, Filippo

    2011-01-01

    The aim of this study was to quantify the gait patterns of adults with joint hypermobility syndrome/Ehlers-Danlos syndrome (JHS/EDS-HT) hypermobility type, using Gait Analysis. We quantified the gait strategy in 12 JHS/EDS-HT adults individuals (age: 43.08+6.78 years) compared to 20 healthy controls (age: 37.23±8.91 years), in terms of kinematics and kinetics. JHS/EDS-HT individuals were characterized by a non-physiological gait pattern. In particular, spatio-temporal parameters evidenced lower anterior step length and higher stance phase duration in JHS/EDS-HT than controls. In term of kinematics, in JHS/EDS-HT patients the main gait limitations involved pelvis, distal joints and ankle joint. Conversely, hip and knee joint showed physiological values. Ankle moment and power revealed reduced peak values during terminal stance. Differences in stiffness at hip and ankle joints were found between JHS/EDS-HT and controls. JHS/EDS-HT patients showed significant decreased of Kh and Ka parameters very probably due to congenital hypotonia and ligament laxity. These findings help to elucidate the complex biomechanical changes in JHS/EDS-HT and may have a major role in the multidimensional evaluation and tailored management of these patients.

  9. Gait analysis.

    PubMed

    Chester, Victoria L; Biden, Edmund N; Tingley, Maureen

    2005-01-01

    Gait analysis, or the study of locomotion, has changed dramatically over the last few decades. Advances in computer technology and data analysis techniques have contributed greatly to the progress of this field. Gait analysis has become a valuable tool in the clinical setting. The ability to objectively quantify motion is essential to our understanding of normal and abnormal movement patterns and the evaluation of treatment effectiveness. This paper will discuss the various experimental and analytical techniques currently used for performing clinical gait analyses at the University of New Brunswick, Fredericton, New Brunswick, Canada.

  10. Validation of hip joint center localization methods during gait analysis using 3D EOS imaging in typically developing and cerebral palsy children.

    PubMed

    Assi, Ayman; Sauret, Christophe; Massaad, Abir; Bakouny, Ziad; Pillet, Hélène; Skalli, Wafa; Ghanem, Ismat

    2016-07-01

    Localization of the hip joint center (HJC) is essential in computation of gait data. EOS low dose biplanar X-rays have been shown to be a good reference in evaluating various methods of HJC localization in adults. The aim is to evaluate predictive and functional techniques for HJC localization in typically developing (TD) and cerebral palsy (CP) children, using EOS as an image based reference. Eleven TD and 17 CP children underwent 3D gait analysis. Six HJC localization methods were evaluated in each group bilaterally: 3 predictive (Plug in Gait, Bell and Harrington) and 3 functional methods based on the star arc technique (symmetrical center of rotation estimate, center transformation technique and geometrical sphere fitting). All children then underwent EOS low dose biplanar radiographs. Pelvis, lower limbs and their corresponding external markers were reconstructed in 3D. The center of the femoral head was considered as the reference (HJCEOS). Euclidean distances between HJCs estimated by each of the 6 methods and the HJCEOS were calculated; distances were shown to be lower in predictive compared to functional methods (p<0.0001). Contrarily to findings in adults, functional methods were shown to be less accurate than predictive methods in TD and CP children, which could be mainly due to the shorter thigh segment in children. Harrington method was shown to be the most accurate in the prediction of HJC (mean error≈18mm, SD=9mm) and quasi-equivalent to the Bell method. The bias for each method was quantified, allowing its correction for an improved HJC estimation.

  11. Action and gait recognition from recovered 3-D human joints.

    PubMed

    Gu, Junxia; Ding, Xiaoqing; Wang, Shengjin; Wu, Youshou

    2010-08-01

    A common viewpoint-free framework that fuses pose recovery and classification for action and gait recognition is presented in this paper. First, a markerless pose recovery method is adopted to automatically capture the 3-D human joint and pose parameter sequences from volume data. Second, multiple configuration features (combination of joints) and movement features (position, orientation, and height of the body) are extracted from the recovered 3-D human joint and pose parameter sequences. A hidden Markov model (HMM) and an exemplar-based HMM are then used to model the movement features and configuration features, respectively. Finally, actions are classified by a hierarchical classifier that fuses the movement features and the configuration features, and persons are recognized from their gait sequences with the configuration features. The effectiveness of the proposed approach is demonstrated with experiments on the Institut National de Recherche en Informatique et Automatique Xmas Motion Acquisition Sequences data set.

  12. Monocular 3-D gait tracking in surveillance scenes.

    PubMed

    Rogez, Grégory; Rihan, Jonathan; Guerrero, Jose J; Orrite, Carlos

    2014-06-01

    Gait recognition can potentially provide a noninvasive and effective biometric authentication from a distance. However, the performance of gait recognition systems will suffer in real surveillance scenarios with multiple interacting individuals and where the camera is usually placed at a significant angle and distance from the floor. We present a methodology for view-invariant monocular 3-D human pose tracking in man-made environments in which we assume that observed people move on a known ground plane. First, we model 3-D body poses and camera viewpoints with a low dimensional manifold and learn a generative model of the silhouette from this manifold to a reduced set of training views. During the online stage, 3-D body poses are tracked using recursive Bayesian sampling conducted jointly over the scene's ground plane and the pose-viewpoint manifold. For each sample, the homography that relates the corresponding training plane to the image points is calculated using the dominant 3-D directions of the scene, the sampled location on the ground plane and the sampled camera view. Each regressed silhouette shape is projected using this homographic transformation and is matched in the image to estimate its likelihood. Our framework is able to track 3-D human walking poses in a 3-D environment exploring only a 4-D state space with success. In our experimental evaluation, we demonstrate the significant improvements of the homographic alignment over a commonly used similarity transformation and provide quantitative pose tracking results for the monocular sequences with a high perspective effect from the CAVIAR dataset.

  13. Evaluation of a Gait Assessment Module Using 3D Motion Capture Technology

    PubMed Central

    Baskwill, Amanda J.; Belli, Patricia; Kelleher, Leila

    2017-01-01

    Background Gait analysis is the study of human locomotion. In massage therapy, this observation is part of an assessment process that informs treatment planning. Massage therapy students must apply the theory of gait assessment to simulated patients. At Humber College, the gait assessment module traditionally consists of a textbook reading and a three-hour, in-class session in which students perform gait assessment on each other. In 2015, Humber College acquired a three-dimensional motion capture system. Purpose The purpose was to evaluate the use of 3D motion capture in a gait assessment module compared to the traditional gait assessment module. Participants Semester 2 massage therapy students who were enrolled in Massage Theory 2 (n = 38). Research Design Quasi-experimental, wait-list comparison study. Intervention The intervention group participated in an in-class session with a Qualisys motion capture system. Main Outcome Measure(s) The outcomes included knowledge and application of gait assessment theory as measured by quizzes, and students’ satisfaction as measured through a questionnaire. Results There were no statistically significant differences in baseline and post-module knowledge between both groups (pre-module: p = .46; post-module: p = .63). There was also no difference between groups on the final application question (p = .13). The intervention group enjoyed the in-class session because they could visualize the content, whereas the comparison group enjoyed the interactivity of the session. The intervention group recommended adding the assessment of gait on their classmates to their experience. Both groups noted more time was needed for the gait assessment module. Conclusions Based on the results of this study, it is recommended that the gait assessment module combine both the traditional in-class session and the 3D motion capture system. PMID:28293329

  14. Gait analysis: clinical facts.

    PubMed

    Baker, Richard; Esquenazi, Alberto; Benedetti, Maria G; Desloovere, Kaat

    2016-08-01

    Gait analysis is a well-established tool for the quantitative assessment of gait disturbances providing functional diagnosis, assessment for treatment planning, and monitoring of disease progress. There is a large volume of literature on the research use of gait analysis, but evidence on its clinical routine use supports a favorable cost-benefit ratio in a limited number of conditions. Initially gait analysis was introduced to clinical practice to improve the management of children with cerebral palsy. However, there is good evidence to extend its use to patients with various upper motor neuron diseases, and to lower limb amputation. Thereby, the methodology for properly conducting and interpreting the exam is of paramount relevance. Appropriateness of gait analysis prescription and reliability of data obtained are required in the clinical environment. This paper provides an overview on guidelines for managing a clinical gait analysis service and on the principal clinical domains of its application: cerebral palsy, stroke, traumatic brain injury and lower limb amputation.

  15. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  16. Underwater gait analysis in Parkinson's disease.

    PubMed

    Volpe, Daniele; Pavan, Davide; Morris, Meg; Guiotto, Annamaria; Iansek, Robert; Fortuna, Sofia; Frazzitta, Giuseppe; Sawacha, Zimi

    2017-02-01

    Although hydrotherapy is one of the physical therapies adopted to optimize gait rehabilitation in people with Parkinson disease, the quantitative measurement of gait-related outcomes has not been provided yet. This work aims to document the gait improvements in a group of parkinsonians after a hydrotherapy program through 2D and 3D underwater and on land gait analysis. Thirty-four parkinsonians and twenty-two controls were enrolled, divided into two different cohorts. In the first one, 2 groups of patients underwent underwater or land based walking training; controls underwent underwater walking training. Hence pre-treatment 2D underwater and on land gait analysis were performed, together with post-treatment on land gait analysis. Considering that current literature documented a reduced movement amplitude in parkinsonians across all lower limb joints in all movement planes, 3D underwater and on land gait analysis were performed on a second cohort of subjects (10 parkinsonians and 10 controls) who underwent underwater gait training. Baseline land 2D and 3D gait analysis in parkinsonians showed shorter stride length and slower speed than controls, in agreement with previous findings. Comparison between underwater and on land gait analysis showed reduction in stride length, cadence and speed on both parkinsonians and controls. Although patients who underwent underwater treatment exhibited significant changes on spatiotemporal parameters and sagittal plane lower limb kinematics, 3D gait analysis documented a significant (p<0.05) improvement in all movement planes. These data deserve attention for research directions promoting the optimal recovery and maintenance of walking ability.

  17. Markerless motion capture can provide reliable 3D gait kinematics in the sagittal and frontal plane.

    PubMed

    Sandau, Martin; Koblauch, Henrik; Moeslund, Thomas B; Aanæs, Henrik; Alkjær, Tine; Simonsen, Erik B

    2014-09-01

    Estimating 3D joint rotations in the lower extremities accurately and reliably remains unresolved in markerless motion capture, despite extensive studies in the past decades. The main problems have been ascribed to the limited accuracy of the 3D reconstructions. Accordingly, the purpose of the present study was to develop a new approach based on highly detailed 3D reconstructions in combination with a translational and rotational unconstrained articulated model. The highly detailed 3D reconstructions were synthesized from an eight camera setup using a stereo vision approach. The subject specific articulated model was generated with three rotational and three translational degrees of freedom for each limb segment and without any constraints to the range of motion. This approach was tested on 3D gait analysis and compared to a marker based method. The experiment included ten healthy subjects in whom hip, knee and ankle joint were analysed. Flexion/extension angles as well as hip abduction/adduction closely resembled those obtained from the marker based system. However, the internal/external rotations, knee abduction/adduction and ankle inversion/eversion were less reliable.

  18. Gait Analysis Using Wearable Sensors

    PubMed Central

    Tao, Weijun; Liu, Tao; Zheng, Rencheng; Feng, Hutian

    2012-01-01

    Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications. PMID:22438763

  19. Gait analysis using wearable sensors.

    PubMed

    Tao, Weijun; Liu, Tao; Zheng, Rencheng; Feng, Hutian

    2012-01-01

    Gait analysis using wearable sensors is an inexpensive, convenient, and efficient manner of providing useful information for multiple health-related applications. As a clinical tool applied in the rehabilitation and diagnosis of medical conditions and sport activities, gait analysis using wearable sensors shows great prospects. The current paper reviews available wearable sensors and ambulatory gait analysis methods based on the various wearable sensors. After an introduction of the gait phases, the principles and features of wearable sensors used in gait analysis are provided. The gait analysis methods based on wearable sensors is divided into gait kinematics, gait kinetics, and electromyography. Studies on the current methods are reviewed, and applications in sports, rehabilitation, and clinical diagnosis are summarized separately. With the development of sensor technology and the analysis method, gait analysis using wearable sensors is expected to play an increasingly important role in clinical applications.

  20. Summary measures for clinical gait analysis: a literature review.

    PubMed

    Cimolin, Veronica; Galli, Manuela

    2014-04-01

    Instrumented 3D-gait analysis (3D-GA) is an important method used to obtain information that is crucial for establishing the level of functional limitation due to pathology, observing its evolution over time and evaluating rehabilitative intervention effects. However, a typical 3D-GA evaluation produces a vast amount of data, and despite its objectivity, its use is complicated, and the data interpretation is difficult. It is even more difficult to obtain an overview on patient cohorts for a comparison. Moreover, there is a growing awareness of the need for a concise index, specifically, a single measure of the 'quality' of a particular gait pattern. Several gait summary measures, which have been used in conjunction with 3D-GA, have been proposed to objectify clinical impression, quantify the degree of gait deviation from normal, stratify the severity of pathology, document the changes in gait patterns over time and evaluate interventions.

  1. Terminology and forensic gait analysis.

    PubMed

    Birch, Ivan; Vernon, Wesley; Walker, Jeremy; Young, Maria

    2015-07-01

    The use of appropriate terminology is a fundamental aspect of forensic gait analysis. The language used in forensic gait analysis is an amalgam of that used in clinical practice, podiatric biomechanics and the wider field of biomechanics. The result can often be a lack of consistency in the language used, the definitions used and the clarity of the message given. Examples include the use of 'gait' and 'walking' as synonymous terms, confusion between 'step' and 'stride', the mixing of anatomical, positional and pathological descriptors, and inability to describe appropriately movements of major body segments such as the torso. The purpose of this paper is to share the well-established definitions of the fundamental parameters of gait, common to all professions, and advocate their use in forensic gait analysis to establish commonality. The paper provides guidance on the selection and use of appropriate terminology in the description of gait in the forensic context. This paper considers the established definitions of the terms commonly used, identifies those terms which have the potential to confuse readers, and suggests a framework of terminology which should be utilised in forensic gait analysis.

  2. Magnitude and pattern of 3D kinematic and kinetic gait profiles in persons with stroke: relationship to walking speed.

    PubMed

    Kim, C Maria; Eng, Janice J

    2004-10-01

    The purpose of this study was to identify 3D kinematic and kinetic gait profiles in individuals with chronic stroke and to determine whether the magnitude or pattern (shape and direction of curve) of these profiles relate to gait performance (as measured by self-selected gait speed). More than one type of kinematic and kinetic pattern was identified in all three planes in 20 individuals with stroke (age: 61.2+/-8.4 years). Persons in the "fast" speed group did not necessarily exhibit the gait patterns closest to the ones reported for healthy adults. For example, in the frontal plane, a variation from the typical pattern (i.e., a hip abductor pattern in swing) was more common among the "fast" group. Correlations revealed that in addition to the sagittal profiles, the magnitudes of the frontal and transverse profiles are also related to speed, particularly the frontal hip powers. The results support the importance of hip abductors, in addition to the sagittal plane muscle groups, for both the paretic and non-paretic limbs. Furthermore, profiles which resemble gait patterns of neurologically healthy adults do not necessarily result in the faster gait speeds for individuals with chronic stroke.

  3. Towards autonomous locomotion: CPG-based control of smooth 3D slithering gait transition of a snake-like robot.

    PubMed

    Bing, Zhenshan; Cheng, Long; Chen, Guang; Röhrbein, Florian; Huang, Kai; Knoll, Alois

    2017-04-04

    Snake-like robots with 3D locomotion ability have significant advantages of adaptive travelling in diverse complex terrain over traditional legged or wheeled mobile robots. Despite numerous developed gaits, these snake-like robots suffer from unsmooth gait transitions by changing the locomotion speed, direction, and body shape, which would potentially cause undesired movement and abnormal torque. Hence, there exists a knowledge gap for snake-like robots to achieve autonomous locomotion. To address this problem, this paper presents the smooth slithering gait transition control based on a lightweight central pattern generator (CPG) model for snake-like robots. First, based on the convergence behavior of the gradient system, a lightweight CPG model with fast computing time was designed and compared with other widely adopted CPG models. Then, by reshaping the body into a more stable geometry, the slithering gait was modified, and studied based on the proposed CPG model, including the gait transition of locomotion speed, moving direction, and body shape. In contrast to sinusoid-based method, extensive simulations and prototype experiments finally demonstrated that smooth slithering gait transition can be effectively achieved using the proposed CPG-based control method without generating undesired locomotion and abnormal torque.

  4. Gait analysis in forensic medicine

    NASA Astrophysics Data System (ADS)

    Larsen, Peter K.; Simonsen, Erik B.; Lynnerup, Niels

    2007-01-01

    We have combined the basic human ability to recognize other individuals with functional anatomical and biomechanical knowledge, in order to analyze the gait of perpetrators as recorded on surveillance video. The perpetrators are then compared with similar analyses of suspects. At present we give a statement to the police as to whether the perpetrator has a characteristic gait pattern compared to normal gait, and if a suspect has a comparable gait pattern. We have found agreements such as: limping, varus instability in the knee at heel strike, larger lateral flexion of the spinal column to one side than the other, inverted ankle during stance, pronounced sagittal head-movements, and marked head-shoulder posture. Based on these characteristic features, we state whether suspect and perpetrator could have the same identity but it is not possible to positively identify the perpetrator. Nevertheless, we have been involved in several cases where the court has found that this type of gait analysis, especially combined with photogrammetry, was a valuable tool. The primary requisites are surveillance cameras recording with sufficient frequency, ideally about 15 Hz, which are positioned in frontal and preferably also in profile view.

  5. Gait analysis and cerebral volumes in Down's syndrome.

    PubMed

    Rigoldi, C; Galli, M; Condoluci, C; Carducci, F; Onorati, P; Albertini, G

    2009-01-01

    The aim of this study was to look for a relationship between cerebral volumes computed using a voxel-based morphometry algorithm and walking patterns in individuals with Down's syndrome (DS), in order to investigate the origin of the motor problems in these subjects with a view to developing appropriate rehabilitation programmes. Nine children with DS underwent a gait analysis (GA) protocol that used a 3D motion analysis system, force plates and a video system, and magnetic resonance imaging (MRI). Analysis of GA graphs allowed a series of parameters to be defined and computed in order to quantify gait patterns. By combining some of the parameters it was possible to obtain a 3D description of gait in terms of distance from normal values. Finally, the results of cerebral volume analysis were compared with the gait patterns found. A strong relationship emerged between cerebellar vermis volume reduction and quality of gait and also between grey matter volume reduction of some cerebral areas and asymmetrical gait. An evaluation of high-level motor deficits, reflected in a lack or partial lack of proximal functions, is important in order to define a correct rehabilitation programme.

  6. [Gait Analysis in Patients with Hip Disorders].

    PubMed

    Urbášek, K; Poul, J

    2016-01-01

    Recent studies have shown that the evaluation of both conservative and surgical therapy cannot do without gait analysis. Orthopaedic textbooks, with some exceptions, deal in great detail with a thorough clinical examination of the patient but gait assessment is mentioned only marginally. More attention is paid to gait analysis in rehabilitation medicine. Motion and gait analysis laboratories equipped with optoelectronic cameras and force platforms were first developed for cerebral palsy children. Recently, several studies have been published on the use of these methods in disorders of hip and knee joints or spine diseases. Key words: gait analysis, hip joint.

  7. A mechanical energy analysis of gait initiation

    NASA Technical Reports Server (NTRS)

    Miller, C. A.; Verstraete, M. C.

    1999-01-01

    The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.

  8. Differences in implementation of gait analysis recommendations based on affiliation with a gait laboratory.

    PubMed

    Wren, Tishya A L; Elihu, Koorosh J; Mansour, Shaun; Rethlefsen, Susan A; Ryan, Deirdre D; Smith, Michelle L; Kay, Robert M

    2013-02-01

    This study examined the extent to which gait analysis recommendations are followed by orthopedic surgeons with varying degrees of affiliation with the gait laboratory. Surgical data were retrospectively examined for 95 patients with cerebral palsy who underwent lower extremity orthopedic surgery following gait analysis. Thirty-three patients were referred by two surgeons directly affiliated with the gait laboratory (direct affiliation), 44 were referred by five surgeons from the same institution but not directly affiliated with the gait laboratory (institutional affiliation), and 18 were referred by 10 surgeons from other institutions (no affiliation). Data on specific surgeries were collected from the gait analysis referral, gait analysis report, and operative notes. Adherence to the gait analysis recommendations was calculated by dividing the number of procedures where the surgery followed the gait analysis recommendation (numerator) by the total number of procedures initially planned, recommended by gait analysis, or done (denominator). Adherence with the gait analysis recommendations was 97%, 94%, and 77% for the direct, institutional, and no affiliation groups, respectively. Procedures recommended for additions to the surgical plan were added 98%, 87%, and 77% of the time. Procedures recommended for elimination were dropped 100%, 89%, and 88% of the time. Of 81 patients who had specific surgical plans prior to gait analysis, changes were implemented in 84% (68/81) following gait analysis recommendations. Gait analysis influences the treatment decisions of surgeons regardless of affiliation with the gait laboratory, although the influence is stronger for surgeons who practice within the same institution as the gait laboratory.

  9. Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait.

    PubMed

    Guan, Shanyuanye; Gray, Hans A; Keynejad, Farzad; Pandy, Marcus G

    2016-01-01

    Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human body movement for high-speed imaging of 3D joint motion during overground gait. A robotic gantry mechanism translates the two X-ray units alongside the subject, tracking and imaging the joint of interest as the subject moves. The main aim of the present study was to determine the accuracy with which the mobile imaging system measures 3D knee-joint kinematics during walking. In vitro experiments were performed to measure the relative positions of the tibia and femur in an intact human cadaver knee and of the tibial and femoral components of a total knee arthroplasty (TKA) implant during simulated overground gait. Accuracy was determined by calculating mean, standard deviation and root-mean-squared errors from differences between kinematic measurements obtained using volumetric models of the bones and TKA components and reference measurements obtained from metal beads embedded in the bones. Measurement accuracy was enhanced by the ability to track and image the joint concurrently. Maximum root-mean-squared errors were 0.33 mm and 0.65° for translations and rotations of the TKA knee and 0.78 mm and 0.77° for translations and rotations of the intact knee, which are comparable to results reported for treadmill walking using stationary biplane systems. System capability for in vivo joint motion measurement was also demonstrated for overground gait.

  10. 3-D analysis of grain selection process

    NASA Astrophysics Data System (ADS)

    Arao, Tomoka; Esaka, Hisao; Shinozuka, Kei

    2012-07-01

    It is known that the grain selection plays an important role in the manufacturing process for turbine blades. There are some analytical or numerical models to treat the grain selection. However, the detailed mechanism of grain selection in 3-D is still uncertain. Therefore, an experimental research work using Al-Cu alloy has been carried out in order to understand the grain selection in 3-D.A mold made by Al2O3 was heated to 600 °C ( = liquids temperature of the alloy) and was set on a water-colded copper chill plate. Molten Al-20 wt%Cu alloy was cast into the mold and unidirectional solidified ingot was prepared. The size of ingot was approximately phi25×65H mm. To obtain the thermal history, 4 thermocouples were placed in the mold. It is confirmed that the alloy solidified unidirectionally from bottom to top. Solidified structure on a longitudinal cross section was observed and unidirectional solidification up to 40 mm was ensured. EBSD analysis has been performed on horizontal cross section at an interval of ca.200 μm. These observations were carried out 7-5 mm from the bottom surface. Crystallographic orientation of primary Al phase and size of solidified grains were characterized. A large solidified grain, the crystallographic orientation of which is approximately <101> along heat flow direction, is observed near the lowest cross section. The area of <101> grain decreased as solidification proceeded. On the other hand, it is found that the area of <001> grain increased.

  11. Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry.

    PubMed

    Plooij, J M; Swennen, G R J; Rangel, F A; Maal, T J J; Schutyser, F A C; Bronkhorst, E M; Kuijpers-Jagtman, A M; Bergé, S J

    2009-03-01

    In 3D photographs the bony structures are neither available nor palpable, therefore, the bone-related landmarks, such as the soft tissue gonion, need to be redefined. The purpose of this study was to determine the reproducibility and reliability of 49 soft tissue landmarks, including newly defined 3D bone-related soft tissue landmarks with the use of 3D stereophotogrammetric images. Two observers carried out soft-tissue analysis on 3D photographs twice for 20 patients. A reference frame and 49 landmarks were identified on each 3D photograph. Paired Student's t-test was used to test the reproducibility and Pearson's correlation coefficient to determine the reliability of the landmark identification. Intra- and interobserver reproducibility of the landmarks were high. The study showed a high reliability coefficient for intraobserver (0.97 (0.90 - 0.99)) and interobserver reliability (0.94 (0.69 - 0.99)). Identification of the landmarks in the midline was more precise than identification of the paired landmarks. In conclusion, the redefinition of bone-related soft tissue 3D landmarks in combination with the 3D photograph reference system resulted in an accurate and reliable 3D photograph based soft tissue analysis. This shows that hard tissue data are not needed to perform accurate soft tissue analysis.

  12. Gait Analysis Laboratory

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Complete motion analysis laboratory has evolved out of analyzing walking patterns of crippled children at Stanford Children's Hospital. Data is collected by placing tiny electrical sensors over muscle groups of child's legs and inserting step-sensing switches in soles of shoes. Miniature radio transmitters send signals to receiver for continuous recording of abnormal walking pattern. Engineers are working to apply space electronics miniaturization techniques to reduce size and weight of telemetry system further as well as striving to increase signal bandwidth so analysis can be performed faster and more accurately using a mini-computer.

  13. Infrastructure for 3D Imaging Test Bed

    DTIC Science & Technology

    2007-05-11

    analysis. (c.) Real time detection & analysis of human gait: using a video camera we capture walking human silhouette for pattern modeling and gait ... analysis . Fig. 5 shows the scanning result result that is fed into a Geo-magic software tool for 3D meshing. Fig. 5: 3D scanning result In

  14. Optics in gait analysis and anthropometry

    NASA Astrophysics Data System (ADS)

    Silva Moreno, Alejandra Alicia

    2013-11-01

    Since antiquity, human gait has been studied to understand human movement, the kind of gait, in some cases, can cause musculoskeletal disorders or other health problems; in addition, also from antiquity, anthropometry has been important for the design of human items such as workspaces, tools, garments, among others. Nowadays, thanks to the development of optics and electronics, more accurate studies of gait and anthropometry can be developed. This work will describe the most important parameters for gait analysis, anthropometry and the optical systems used.

  15. 3D face analysis for demographic biometrics

    SciTech Connect

    Tokola, Ryan A; Mikkilineni, Aravind K; Boehnen, Chris Bensing

    2015-01-01

    Despite being increasingly easy to acquire, 3D data is rarely used for face-based biometrics applications beyond identification. Recent work in image-based demographic biometrics has enjoyed much success, but these approaches suffer from the well-known limitations of 2D representations, particularly variations in illumination, texture, and pose, as well as a fundamental inability to describe 3D shape. This paper shows that simple 3D shape features in a face-based coordinate system are capable of representing many biometric attributes without problem-specific models or specialized domain knowledge. The same feature vector achieves impressive results for problems as diverse as age estimation, gender classification, and race classification.

  16. Gait Analysis by High School Students

    ERIC Educational Resources Information Center

    Heck, Andre; van Dongen, Caroline

    2008-01-01

    Human walking is a complicated motion. Movement scientists have developed various research methods to study gait. This article describes how a high school student collected and analysed high quality gait data in much the same way that movement scientists do, via the recording and measurement of motions with a video analysis tool and via…

  17. Tilted planes in 3D image analysis

    NASA Astrophysics Data System (ADS)

    Pargas, Roy P.; Staples, Nancy J.; Malloy, Brian F.; Cantrell, Ken; Chhatriwala, Murtuza

    1998-03-01

    Reliable 3D wholebody scanners which output digitized 3D images of a complete human body are now commercially available. This paper describes a software package, called 3DM, being developed by researchers at Clemson University and which manipulates and extracts measurements from such images. The focus of this paper is on tilted planes, a 3DM tool which allows a user to define a plane through a scanned image, tilt it in any direction, and effectively define three disjoint regions on the image: the points on the plane and the points on either side of the plane. With tilted planes, the user can accurately take measurements required in applications such as apparel manufacturing. The user can manually segment the body rather precisely. Tilted planes assist the user in analyzing the form of the body and classifying the body in terms of body shape. Finally, titled planes allow the user to eliminate extraneous and unwanted points often generated by a 3D scanner. This paper describes the user interface for tilted planes, the equations defining the plane as the user moves it through the scanned image, an overview of the algorithms, and the interaction of the tilted plane feature with other tools in 3DM.

  18. Accelerometer and gyroscope based gait analysis using spectral analysis of patients with osteoarthritis of the knee.

    PubMed

    Staab, Wieland; Hottowitz, Ralf; Sohns, Christian; Sohns, Jan Martin; Gilbert, Fabian; Menke, Jan; Niklas, Andree; Lotz, Joachim

    2014-07-01

    [Purpose] A wide variety of accelerometer tools are used to estimate human movement, but there are no adequate data relating to gait symmetry parameters in the context of knee osteoarthritis. This study's purpose was to evaluate a 3D-kinematic system using body-mounted sensors (gyroscopes and accelerometers) on the trunk and limbs. This is the first study to use spectral analysis for data post processing. [Subjects] Twelve patients with unilateral knee osteoarthritis (OA) (10 male) and seven age-matched controls (6 male) were studied. [Methods] Measurements with 3-D accelerometers and gyroscopes were compared to video analysis with marker positions tracked by a six-camera optoelectronic system (VICON 460, Oxford Metrics). Data were recorded using the 3D-kinematic system. [Results] The results of both gait analysis systems were significantly correlated. Five parameters were significantly different between the knee OA and control groups. To overcome time spent in expensive post-processing routines, spectral analysis was performed for fast differentiation between normal gait and pathological gait signals using the 3D-kinematic system. [Conclusions] The 3D-kinematic system is objective, inexpensive, accurate and portable, and allows long-term recordings in clinical, sport as well as ergonomic or functional capacity evaluation (FCE) settings. For fast post-processing, spectral analysis of the recorded data is recommended.

  19. A motor cortex excitability and gait analysis on Parkinsonian patients.

    PubMed

    Vacherot, François; Attarian, Shahram; Vaugoyeau, Marianne; Azulay, Jean-Philippe

    2010-12-15

    Transcranial magnetic stimulation (TMS) parameters were recorded in a lower limb muscle and correlated with the gait parameters of 25 patients with Parkinson's disease (PD) with and without dopamine substitution treatment (DST) and 10 control subjects. Single and paired-pulse TMS were recorded in the tibialis anterior muscle (TA). Gait analysis was performed using a 3D motion analysis system. Parkinsonian patients (PP) did not differ from the control subjects (CS) in terms of relaxed motor threshold, active motor threshold (AMT), cortical silent period (CSP), motor-evoked potential (MEP) amplitude and area, or paired-pulse TMS with short interstimulus intervals (ISI). At longer ISIs, paired-pulse TMS showed that the amplitudes of the conditioned MEPs were lower in untreated PP than in CS. DST partially compensated for this difference. Gait analysis showed that the gait of PP undergoing no treatment was slower and the stride length shorter than normal. Both of these parameters improved under DST, however. Analysis of data obtained on all the subjects combined showed that both of the latter parameters were correlated with the paired-pulse MEP amplitude and area at longer ISIs. In PP, the cortical areas responsible for the lower limb movements seem to undergo intracortical facilitation (ICF) impairments, whereas the intracortical inhibition process is normal. The ICF level was found to be associated to the stride length and the velocity. The fact that only these two gait parameters were found to be dopa responsive indicates that dopaminergic treatment may improve gait disorders by restoring the ICF.

  20. Motion based markerless gait analysis using standard events of gait and ensemble Kalman filtering.

    PubMed

    Vishnoi, Nalini; Mitra, Anish; Duric, Zoran; Gerber, Naomi Lynn

    2014-01-01

    We present a novel approach to gait analysis using ensemble Kalman filtering which permits markerless determination of segmental movement. We use image flow analysis to reliably compute temporal and kinematic measures including the translational velocity of the torso and rotational velocities of the lower leg segments. Detecting the instances where velocity changes direction also determines the standard events of a gait cycle (double-support, toe-off, mid-swing and heel-strike). In order to determine the kinematics of lower limbs, we model the synergies between the lower limb motions (thigh-shank, shank-foot) by building a nonlinear dynamical system using CMUs 3D motion capture database. This information is fed into the ensemble Kalman Filter framework to estimate the unobserved limb (upper leg and foot) motion from the measured lower leg rotational velocity. Our approach does not require calibrated cameras or special markers to capture movement. We have tested our method on different gait sequences collected from the sagttal plane and presented the estimated kinematics overlaid on the original image frames. We have also validated our approach by manually labeling the videos and comparing our results against them.

  1. Variations in kinematics during clinical gait analysis in stroke patients.

    PubMed

    Boudarham, Julien; Roche, Nicolas; Pradon, Didier; Bonnyaud, Céline; Bensmail, Djamel; Zory, Raphael

    2013-01-01

    In addition to changes in spatio-temporal and kinematic parameters, patients with stroke exhibit fear of falling as well as fatigability during gait. These changes could compromise interpretation of data from gait analysis. The aim of this study was to determine if the gait of hemiplegic patients changes significantly over successive gait trials. Forty two stroke patients and twenty healthy subjects performed 9 gait trials during a gait analysis session. The mean and variability of spatio-temporal and kinematic joint parameters were analyzed during 3 groups of consecutive gait trials (1-3, 4-6 and 7-9). Principal component analysis was used to reduce the number of variables from the joint kinematic waveforms and to identify the parts of the gait cycle which changed during the gait analysis session. The results showed that i) spontaneous gait velocity and the other spatio-temporal parameters significantly increased, and ii) gait variability decreased, over the last 6 gait trials compared to the first 3, for hemiplegic patients but not healthy subjects. Principal component analysis revealed changes in the sagittal waveforms of the hip, knee and ankle for hemiplegic patients after the first 3 gait trials. These results suggest that at the beginning of the gait analysis session, stroke patients exhibited phase of adaptation,characterized by a "cautious gait" but no fatigue was observed.

  2. 3D Frame Buffers For Interactive Analysis Of 3D Data

    NASA Astrophysics Data System (ADS)

    Hunter, Gregory M.

    1984-10-01

    Two-dimensional data such as photos, X rays, various types of satellite images, sonar, radar, seismic plots, etc., in many cases must be analyzed using frame buffers for purposes of medical diagnoses, crop estimates, mineral exploration, and so forth. In many cases the same types of sensors used to gather such samples in two dimensions can gather 3D data for even more effective analysis. Just as 2D arrays of data can be analyzed using frame buffers, three-dimensional data can be analyzed using SOLIDS-BUFFEPmemories. Image processors deal with samples from two-dimensional arrays, and are based on frame buffers. The SOLIDS PROCESSOR system, deals with samples from a three-dimensional volume, or solid, and is based on a 3D frame buffer. This paper focuses upon the SOLIDS-BUFFER system, as used in the INSIGHT SOLIDS-PROCESSOR system from Phoenix Data Systems.

  3. In situ UV curable 3D printing of multi-material tri-legged soft bot with spider mimicked multi-step forward dynamic gait

    NASA Astrophysics Data System (ADS)

    Zeb Gul, Jahan; Yang, Bong-Su; Yang, Young Jin; Chang, Dong Eui; Choi, Kyung Hyun

    2016-11-01

    Soft bots have the expedient ability of adopting intricate postures and fitting in complex shapes compared to mechanical robots. This paper presents a unique in situ UV curing three-dimensional (3D) printed multi-material tri-legged soft bot with spider mimicked multi-step dynamic forward gait using commercial bio metal filament (BMF) as an actuator. The printed soft bot can produce controllable forward motion in response to external signals. The fundamental properties of BMF, including output force, contractions at different frequencies, initial loading rate, and displacement-rate are verified. The tri-pedal soft bot CAD model is designed inspired by spider’s legged structure and its locomotion is assessed by simulating strain and displacement using finite element analysis. A customized rotational multi-head 3D printing system assisted with multiple wavelength’s curing lasers is used for in situ fabrication of tri-pedal soft-bot using two flexible materials (epoxy and polyurethane) in three layered steps. The size of tri-pedal soft-bot is 80 mm in diameter and each pedal’s width and depth is 5 mm × 5 mm respectively. The maximum forward speed achieved is 2.7 mm s-1 @ 5 Hz with input voltage of 3 V and 250 mA on a smooth surface. The fabricated tri-pedal soft bot proved its power efficiency and controllable locomotion at three input signal frequencies (1, 2, 5 Hz).

  4. Gait analysis by high school students

    NASA Astrophysics Data System (ADS)

    Heck, André; van Dongen, Caroline

    2008-05-01

    Human walking is a complicated motion. Movement scientists have developed various research methods to study gait. This article describes how a high school student collected and analysed high quality gait data in much the same way that movement scientists do, via the recording and measurement of motions with a video analysis tool and via electromyography, i.e., the measurement of muscle activity. Physics, biology, and mathematics come together in this practical investigation work at a rather high level. It shows that science learning at school can resemble science practice in research laboratories, provided that students have adequate tools.

  5. Inertial sensor based gait analysis discriminates subjects with and without visual impairment caused by simulated macular degeneration.

    PubMed

    Kanzler, Christoph M; Barth, Jens; Klucken, Jochen; Eskofier, Bjoern M

    2016-08-01

    Macular degeneration is the third leading cause of blindness worldwide and the leading cause of blindness in the developing world. The analysis of gait parameters can be used to assess the influence of macular degeneration on gait. This study examines the effect of macular degeneration on gait using inertial sensor based 3D spatio-temporal gait parameters. We acquired gait data from 21 young and healthy subjects during a 40 m obstacle walk. All subjects had to perform the gait trial with and without macular degeneration simulation glasses. The order of starting with or without glasses alternated between each subject in order to test for training effects. Multiple 3D spatio-temporal gait parameters were calculated for the normal vision as well as the impaired vision groups. The parameters trial time, stride time, stride time coefficient of variation (CV), stance time, stance time CV, stride length, cadence, gait velocity and angle at toe off showed statistically significant differences between the two groups. Training effects were visible for the trials which started without vision impairment. Inter-group differences in the gait pattern occurred due to an increased sense of insecurity related with the loss of visual acuity from the simulation glasses. In summary, we showed that 3D spatio-temporal gait parameters derived from inertial sensor data are viable to detect differences in the gait pattern of subjects with and without a macular degeneration simulation. We believe that this study provides the basis for an in-depth analysis regarding the impact of macular degeneration on gait.

  6. A 3-D biomechanical skeleton model for posture and movement analysis.

    PubMed

    D'Amico, Moreno; D'Amico, Gabriele; Roncoletta, Piero

    2006-01-01

    A project to merge into a full 3D reliable and detailed human skeleton representation various segmental biomechanical models presented in literature has been undertaken by our group. The obtained 3D skeleton model is fully parametric and can so be fitted to each subject anthropometric characteristics. A non-ionizing approach based on 3D opto-electronic measurements of body landmarks labelled by passive markers has been chosen to build the 3D parametric biomechanical skeleton model. To this aim various protocols involving different body labelling (and so different related anthropometric data) have been established for different analyses. To analyse human posture and spinal related pathologies, a 27 markers protocol has been set for static analysis, while 49 markers protocol has been set for gait and movement analysis. A special focus has been devoted to identify and model the spine with a correct degree of accuracy and reliability. To this aim complex signal processing and optimisation procedures have been tested. The model is able to fully integrate information deriving from other measurements devices as force platform data, surface EMG, foot pressure maps. The presented model is the first proposed in literature, to authors knowledge, able to process such multifactorial information to perform a full kinematic and kinetic analysis with particular focus on the spine. Several hundreds of patients have been already analysed and followed up with this methodology that proved to be useful for various posture and spine related pathologies (in particular spine deformities, low-back pain etc.).

  7. 3-D object-oriented image analysis of geophysical data

    NASA Astrophysics Data System (ADS)

    Fadel, I.; Kerle, N.; van der Meijde, M.

    2014-07-01

    Geophysical data are the main source of information about the subsurface. Geophysical techniques are, however, highly non-unique in determining specific physical parameters and boundaries of subsurface objects. To obtain actual physical information, an inversion process is often applied, in which measurements at or above the Earth surface are inverted into a 2- or 3-D subsurface spatial distribution of the physical property. Interpreting these models into structural objects, related to physical processes, requires a priori knowledge and expert analysis which is susceptible to subjective choices and is therefore often non-repeatable. In this research, we implemented a recently introduced object-based approach to interpret the 3-D inversion results of a single geophysical technique using the available a priori information and the physical and geometrical characteristics of the interpreted objects. The introduced methodology is semi-automatic and repeatable, and allows the extraction of subsurface structures using 3-D object-oriented image analysis (3-D OOA) in an objective knowledge-based classification scheme. The approach allows for a semi-objective setting of thresholds that can be tested and, if necessary, changed in a very fast and efficient way. These changes require only changing the thresholds used in a so-called ruleset, which is composed of algorithms that extract objects from a 3-D data cube. The approach is tested on a synthetic model, which is based on a priori knowledge on objects present in the study area (Tanzania). Object characteristics and thresholds were well defined in a 3-D histogram of velocity versus depth, and objects were fully retrieved. The real model results showed how 3-D OOA can deal with realistic 3-D subsurface conditions in which the boundaries become fuzzy, the object extensions become unclear and the model characteristics vary with depth due to the different physical conditions. As expected, the 3-D histogram of the real data was

  8. USJ metrology: from 0D to 3D analysis

    SciTech Connect

    Vandervorst, Wilfried

    2007-09-26

    The analysis of ultra shallow junctions is becoming a challenging task for which numerous tools and concepts are available. The requirements range from a simple 0D-analysis such as the integral dose or the sheet resistance over a simple 1D-profile (as obtained on blanket films) towards the 2D-dopant profile within a transistor. The ultimate complexity will be the analysis of a complete 3D-structure such as a FINFET, requiring a metrology tool with 3D-resolution. In each of these areas significant progress has been made in recent years and new concepts are emerging which will be discussed in this review.

  9. Real-time gait analysis for diagnosing movement disorders

    NASA Astrophysics Data System (ADS)

    Green, Richard D.; Guan, Ling; Burne, J. A.

    1998-06-01

    This paper describes a video analysis system, free of markers and set-up procedures, that quantitatively identified gait abnormalities in real-time from standard video images. A novel color 3D body model was sized and texture mapped to the exact characteristics of a person from video images. The kinematics of the body model was represented by a transformation tree to track the position and orientation of a person relative to the camera. Joint angles were used to track the location and orientation of each body part, with the range of joint angles being constrained by associating degrees of freedom with each joint. To stabilize tracking, the joint angles were estimated for the next frame. The calculation of joint angles, for the next frame, was cast as an estimation problem which was solved using an iterated extended Kalman filter. Patients with dopa-responsive parkinsonism, and age matched normals, were video taped during several gait cycles with walking movements successfully tracked and classified. The results suggested that this approach has the potential to guide clinicians on the relative sensitivity of specific postural/gait features in diagnosis.

  10. Analysis of temporal stability of autostereoscopic 3D displays

    NASA Astrophysics Data System (ADS)

    Rubiño, Manuel; Salas, Carlos; Pozo, Antonio M.; Castro, J. J.; Pérez-Ocón, Francisco

    2013-11-01

    An analysis has been made of the stability of the images generated by electronic autostereoscopic 3D displays, studying the time course of the photometric and colorimetric parameters. The measurements were made on the basis of the procedure recommended in the European guideline EN 61747-6 for the characterization of electronic liquid-crystal displays (LCD). The study uses 3 different models of autostereoscopic 3D displays of different sizes and numbers of pixels, taking the measurements with a spectroradiometer (model PR-670 SpectraScan of PhotoResearch). For each of the displays, the time course is shown for the tristimulus values and the chromaticity coordinates in the XYZ CIE 1931 system and values from the time periods required to reach stable values of these parameters are presented. For the analysis of how the procedure recommended in the guideline EN 61747-6 for 2D displays influenced the results, and for the adaption of the procedure to the characterization of 3D displays, the experimental conditions of the standard procedure were varied, making the stability analysis in the two ocular channels (RE and LE) of the 3D mode and comparing the results with those corresponding to the 2D. The results of our study show that the stabilization time of a autostereoscopic 3D display with parallax barrier technology depends on the tristimulus value analysed (X, Y, Z) as well as on the presentation mode (2D, 3D); furthermore, it was found that whether the 3D mode is used depends on the ocular channel evaluated (RE, LE).

  11. 3-D transient analysis of pebble-bed HTGR by TORT-TD/ATTICA3D

    SciTech Connect

    Seubert, A.; Sureda, A.; Lapins, J.; Buck, M.; Bader, J.; Laurien, E.

    2012-07-01

    As most of the acceptance criteria are local core parameters, application of transient 3-D fine mesh neutron transport and thermal hydraulics coupled codes is mandatory for best estimate evaluations of safety margins. This also applies to high-temperature gas cooled reactors (HTGR). Application of 3-D fine-mesh transient transport codes using few energy groups coupled with 3-D thermal hydraulics codes becomes feasible in view of increasing computing power. This paper describes the discrete ordinates based coupled code system TORT-TD/ATTICA3D that has recently been extended by a fine-mesh diffusion solver. Based on transient analyses for the PBMR-400 design, the transport/diffusion capabilities are demonstrated and 3-D local flux and power redistribution effects during a partial control rod withdrawal are shown. (authors)

  12. Visualization and analysis of 3D microscopic images.

    PubMed

    Long, Fuhui; Zhou, Jianlong; Peng, Hanchuan

    2012-01-01

    In a wide range of biological studies, it is highly desirable to visualize and analyze three-dimensional (3D) microscopic images. In this primer, we first introduce several major methods for visualizing typical 3D images and related multi-scale, multi-time-point, multi-color data sets. Then, we discuss three key categories of image analysis tasks, namely segmentation, registration, and annotation. We demonstrate how to pipeline these visualization and analysis modules using examples of profiling the single-cell gene-expression of C. elegans and constructing a map of stereotyped neurite tracts in a fruit fly brain.

  13. Visualization and Analysis of 3D Microscopic Images

    PubMed Central

    Long, Fuhui; Zhou, Jianlong; Peng, Hanchuan

    2012-01-01

    In a wide range of biological studies, it is highly desirable to visualize and analyze three-dimensional (3D) microscopic images. In this primer, we first introduce several major methods for visualizing typical 3D images and related multi-scale, multi-time-point, multi-color data sets. Then, we discuss three key categories of image analysis tasks, namely segmentation, registration, and annotation. We demonstrate how to pipeline these visualization and analysis modules using examples of profiling the single-cell gene-expression of C. elegans and constructing a map of stereotyped neurite tracts in a fruit fly brain. PMID:22719236

  14. 3D quantitative analysis of brain SPECT images

    NASA Astrophysics Data System (ADS)

    Loncaric, Sven; Ceskovic, Ivan; Petrovic, Ratimir; Loncaric, Srecko

    2001-07-01

    The main purpose of this work is to develop a computer-based technique for quantitative analysis of 3-D brain images obtained by single photon emission computed tomography (SPECT). In particular, the volume and location of ischemic lesion and penumbra is important for early diagnosis and treatment of infracted regions of the brain. SPECT imaging is typically used as diagnostic tool to assess the size and location of the ischemic lesion. The segmentation method presented in this paper utilizes a 3-D deformable model in order to determine size and location of the regions of interest. The evolution of the model is computed using a level-set implementation of the algorithm. In addition to 3-D deformable model the method utilizes edge detection and region growing for realization of a pre-processing. Initial experimental results have shown that the method is useful for SPECT image analysis.

  15. Gait Signal Analysis with Similarity Measure

    PubMed Central

    Shin, Seungsoo

    2014-01-01

    Human gait decision was carried out with the help of similarity measure design. Gait signal was selected through hardware implementation including all in one sensor, control unit, and notebook with connector. Each gait signal was considered as high dimensional data. Therefore, high dimensional data analysis was considered via heuristic technique such as the similarity measure. Each human pattern such as walking, sitting, standing, and stepping up was obtained through experiment. By the results of the analysis, we also identified the overlapped and nonoverlapped data relation, and similarity measure analysis was also illustrated, and comparison with conventional similarity measure was also carried out. Hence, nonoverlapped data similarity analysis provided the clue to solve the similarity of high dimensional data. Considered high dimensional data analysis was designed with consideration of neighborhood information. Proposed similarity measure was applied to identify the behavior patterns of different persons, and different behaviours of the same person. Obtained analysis can be extended to organize health monitoring system for specially elderly persons. PMID:25110724

  16. Gait analysis in lower-limb amputation and prosthetic rehabilitation.

    PubMed

    Esquenazi, Alberto

    2014-02-01

    Gait analysis combined with sound clinical judgment plays an important role in elucidating the factors involved in the pathologic prosthetic gait and the selection and effects of available interventions to optimize it. Detailed clinical evaluation of walking contributes to the analysis of the prosthetic gait, but evaluation in the gait laboratory using kinetic and kinematic data is often necessary to quantify and identify the particular contributions of the variables impacting the gait with confidence and assess the results of such intervention. The same approach can be considered when selecting prosthetic components and assessing leg length in this patient population.

  17. A spherical harmonics intensity model for 3D segmentation and 3D shape analysis of heterochromatin foci.

    PubMed

    Eck, Simon; Wörz, Stefan; Müller-Ott, Katharina; Hahn, Matthias; Biesdorf, Andreas; Schotta, Gunnar; Rippe, Karsten; Rohr, Karl

    2016-08-01

    The genome is partitioned into regions of euchromatin and heterochromatin. The organization of heterochromatin is important for the regulation of cellular processes such as chromosome segregation and gene silencing, and their misregulation is linked to cancer and other diseases. We present a model-based approach for automatic 3D segmentation and 3D shape analysis of heterochromatin foci from 3D confocal light microscopy images. Our approach employs a novel 3D intensity model based on spherical harmonics, which analytically describes the shape and intensities of the foci. The model parameters are determined by fitting the model to the image intensities using least-squares minimization. To characterize the 3D shape of the foci, we exploit the computed spherical harmonics coefficients and determine a shape descriptor. We applied our approach to 3D synthetic image data as well as real 3D static and real 3D time-lapse microscopy images, and compared the performance with that of previous approaches. It turned out that our approach yields accurate 3D segmentation results and performs better than previous approaches. We also show that our approach can be used for quantifying 3D shape differences of heterochromatin foci.

  18. 3D Regression Heat Map Analysis of Population Study Data.

    PubMed

    Klemm, Paul; Lawonn, Kai; Glaßer, Sylvia; Niemann, Uli; Hegenscheid, Katrin; Völzke, Henry; Preim, Bernhard

    2016-01-01

    Epidemiological studies comprise heterogeneous data about a subject group to define disease-specific risk factors. These data contain information (features) about a subject's lifestyle, medical status as well as medical image data. Statistical regression analysis is used to evaluate these features and to identify feature combinations indicating a disease (the target feature). We propose an analysis approach of epidemiological data sets by incorporating all features in an exhaustive regression-based analysis. This approach combines all independent features w.r.t. a target feature. It provides a visualization that reveals insights into the data by highlighting relationships. The 3D Regression Heat Map, a novel 3D visual encoding, acts as an overview of the whole data set. It shows all combinations of two to three independent features with a specific target disease. Slicing through the 3D Regression Heat Map allows for the detailed analysis of the underlying relationships. Expert knowledge about disease-specific hypotheses can be included into the analysis by adjusting the regression model formulas. Furthermore, the influences of features can be assessed using a difference view comparing different calculation results. We applied our 3D Regression Heat Map method to a hepatic steatosis data set to reproduce results from a data mining-driven analysis. A qualitative analysis was conducted on a breast density data set. We were able to derive new hypotheses about relations between breast density and breast lesions with breast cancer. With the 3D Regression Heat Map, we present a visual overview of epidemiological data that allows for the first time an interactive regression-based analysis of large feature sets with respect to a disease.

  19. Basic gait analysis based on continuous wave radar.

    PubMed

    Zhang, Jun

    2012-09-01

    A gait analysis method based on continuous wave (CW) radar is proposed in this paper. Time-frequency analysis is used to analyze the radar micro-Doppler echo from walking humans, and the relationships between the time-frequency spectrogram and human biological gait are discussed. The methods for extracting the gait parameters from the spectrogram are studied in depth and experiments on more than twenty subjects have been performed to acquire the radar gait data. The gait parameters are calculated and compared. The gait difference between men and women are presented based on the experimental data and extracted features. Gait analysis based on CW radar will provide a new method for clinical diagnosis and therapy.

  20. 3D Network Analysis for Indoor Space Applications

    NASA Astrophysics Data System (ADS)

    Tsiliakou, E.; Dimopoulou, E.

    2016-10-01

    Indoor space differs from outdoor environments, since it is characterized by a higher level of structural complexity, geometry, as well as topological relations. Indoor space can be considered as the most important component in a building's conceptual modelling, on which applications such as indoor navigation, routing or analysis are performed. Therefore, the conceptual meaning of sub spaces or the activities taking place in physical building boundaries (e.g. walls), require the comprehension of the building's indoor hierarchical structure. The scope of this paper is to perform 3D network analysis in a building's interior and is structured as follows: In Section 1 the definition of indoor space is provided and indoor navigation requirements are analysed. Section 2 describes the processes of indoor space modeling, as well as routing applications. In Section 3, a case study is examined involving a 3D building model generated in CityEngine (exterior shell) and ArcScene (interior parts), in which the use of commercially available software tools (ArcGIS, ESRI), in terms of indoor routing and 3D network analysis, are explored. The fundamentals of performing 3D analysis with the ArcGIS Network Analyst extension were tested. Finally a geoprocessing model was presented, which was specifically designed to be used to interactively find the best route in ArcScene. The paper ends with discussion and concluding remarks on Section 4.

  1. Parkinson's disease classification using gait analysis via deterministic learning.

    PubMed

    Zeng, Wei; Liu, Fenglin; Wang, Qinghui; Wang, Ying; Ma, Limin; Zhang, Yu

    2016-10-28

    Gait analysis plays an important role in maintaining the well-being of human mobility and health care, and is a valuable tool for obtaining quantitative information on motor deficits in Parkinson's disease (PD). In this paper, we propose a method to classify (diagnose) patients with PD and healthy control subjects using gait analysis via deterministic learning theory. The classification approach consists of two phases: a training phase and a classification phase. In the training phase, gait characteristics represented by the gait dynamics are derived from the vertical ground reaction forces under the usual and self-selected paces of the subjects. The gait dynamics underlying gait patterns of healthy controls and PD patients are locally accurately approximated by radial basis function (RBF) neural networks. The obtained knowledge of approximated gait dynamics is stored in constant RBF networks. The gait patterns of healthy controls and PD patients constitute a training set. In the classification phase, a bank of dynamical estimators is constructed for all the training gait patterns. Prior knowledge of gait dynamics represented by the constant RBF networks is embedded in the estimators. By comparing the set of estimators with a test gait pattern of a certain PD patient to be classified (diagnosed), a set of classification errors are generated. The average L1 norms of the errors are taken as the classification measure between the dynamics of the training gait patterns and the dynamics of the test PD gait pattern according to the smallest error principle. When the gait patterns of 93 PD patients and 73 healthy controls are classified with five-fold cross-validation method, the accuracy, sensitivity and specificity of the results are 96.39%, 96.77% and 95.89%, respectively. Based on the results, it may be claimed that the features and the classifiers used in the present study could effectively separate the gait patterns between the groups of PD patients and healthy

  2. [Three-Dimensional Ultrasonic Gait Analysis in Schizophrenic Patients

    PubMed

    Putzhammer, Albert; Heindl, Bernhard; Müller, Jürgen; Broll, Karin; Pfeiff, Liane; Perfahl, Maria; Hess, Linda; Koch, Horst

    2003-05-01

    Schizophrenic disorders as well as neuroleptic treatment can affect locomotion. The study assessed the influence of neuroleptic treatment on human gait via ultrasonic topometric gait analysis. In a control sample the test system proved high test-retest-reliability. Spatial and temporal gait parameters were assessed in schizophrenic patients without neuroleptic treatment (n = 12) and under treatment with conventional neuroleptics (n = 14) and re-assessed after treatment change to the atypical neuroleptic olanzapine in a repeated measures design. After switch from conventional neuroleptics to olanzapine patients showed an increase of gait velocity (p gait is affected by conventional neuroleptic treatment. The degree of impairment can be objectively measured by testing spatio-temporal and kinematic gait parameters via three-dimensional ultrasonic gait analysis.

  3. Low-cost three-dimensional gait analysis system for mice with an infrared depth sensor.

    PubMed

    Nakamura, Akihiro; Funaya, Hiroyuki; Uezono, Naohiro; Nakashima, Kinichi; Ishida, Yasumasa; Suzuki, Tomohiro; Wakana, Shigeharu; Shibata, Tomohiro

    2015-11-01

    Three-dimensional (3D) open-field gait analysis of mice is an essential procedure in genetic and nerve regeneration research. Existing gait analysis systems are generally expensive and may interfere with the natural behaviors of mice because of optical markers and transparent floors. In contrast, the proposed system captures the subjects shape from beneath using a low-cost infrared depth sensor (Microsoft Kinect) and an opaque infrared pass filter. This means that we can track footprints and 3D paw-tip positions without optical markers or a transparent floor, thereby preventing any behavioral changes. Our experimental results suggest with healthy mice that they are more active on opaque floors and spend more time in the center of the open-field, when compared with transparent floors. The proposed system detected footprints with a comparable performance to existing systems, and precisely tracked the 3D paw-tip positions in the depth image coordinates.

  4. 3-D Experimental Fracture Analysis at High Temperature

    SciTech Connect

    John H. Jackson; Albert S. Kobayashi

    2001-09-14

    T*e, which is an elastic-plastic fracture parameter based on incremental theory of plasticity, was determined numerically and experimentally. The T*e integral of a tunneling crack in 2024-T3 aluminum, three point bend specimen was obtained through a hybrid analysis of moire interferometry and 3-D elastic-plastic finite element analysis. The results were verified by the good agreement between the experimentally and numerically determined T*e on the specimen surface.

  5. Gait in adolescent idiopathic scoliosis: kinematics and electromyographic analysis.

    PubMed

    Mahaudens, P; Banse, X; Mousny, M; Detrembleur, C

    2009-04-01

    Adolescent idiopathic scoliosis (AIS) is a progressive growth disease that affects spinal anatomy, mobility, and left-right trunk symmetry. Consequently, AIS can modify human locomotion. Very few studies have investigated a simple activity like walking in a cohort of well-defined untreated patients with scoliosis. The first goal of this study is to evaluate the effects of scoliosis and scoliosis severity on kinematic and electromyographic (EMG) gait variables compared to an able-bodied population. The second goal is to look for any asymmetry in these parameters during walking. Thirteen healthy girls and 41 females with untreated AIS, with left thoracolumbar or lumbar primary structural curves were assessed. AIS patients were divided into three clinical subgroups (group 1 < 20 degrees, group 2 between 20 and 40 degrees, and group 3 > 40 degrees). Gait analysis included synchronous bilateral kinematic and EMG measurements. The subjects walked on a treadmill at 4 km/h (comfortable speed). The tridimensional (3D) shoulder, pelvis, and lower limb motions were measured using 22 reflective markers tracked by four infrared cameras. The EMG timing activity was measured using bipolar surface electrodes on quadratus lumborum, erector spinae, gluteus medius, rectus femoris, semitendinosus, tibialis anterior, and gastrocnemius muscles. Statistical comparisons (ANOVA) were performed across groups and sides for kinematic and EMG parameters. The step length was reduced in AIS compared to normal subjects (7% less). Frontal shoulder, pelvis, and hip motion and transversal hip motion were reduced in scoliosis patients (respectively, 21, 27, 28, and 22% less). The EMG recording during walking showed that the quadratus lumborum, erector spinae, gluteus medius, and semitendinosus muscles contracted during a longer part of the stride in scoliotic patients (46% of the stride) compared with normal subjects (35% of the stride). There was no significant difference between scoliosis groups 1

  6. Gait in adolescent idiopathic scoliosis: kinematics and electromyographic analysis

    PubMed Central

    Banse, X.; Mousny, M.; Detrembleur, C.

    2009-01-01

    Adolescent idiopathic scoliosis (AIS) is a progressive growth disease that affects spinal anatomy, mobility, and left-right trunk symmetry. Consequently, AIS can modify human locomotion. Very few studies have investigated a simple activity like walking in a cohort of well-defined untreated patients with scoliosis. The first goal of this study is to evaluate the effects of scoliosis and scoliosis severity on kinematic and electromyographic (EMG) gait variables compared to an able-bodied population. The second goal is to look for any asymmetry in these parameters during walking. Thirteen healthy girls and 41 females with untreated AIS, with left thoracolumbar or lumbar primary structural curves were assessed. AIS patients were divided into three clinical subgroups (group 1 < 20°, group 2 between 20 and 40°, and group 3 > 40°). Gait analysis included synchronous bilateral kinematic and EMG measurements. The subjects walked on a treadmill at 4 km/h (comfortable speed). The tridimensional (3D) shoulder, pelvis, and lower limb motions were measured using 22 reflective markers tracked by four infrared cameras. The EMG timing activity was measured using bipolar surface electrodes on quadratus lumborum, erector spinae, gluteus medius, rectus femoris, semitendinosus, tibialis anterior, and gastrocnemius muscles. Statistical comparisons (ANOVA) were performed across groups and sides for kinematic and EMG parameters. The step length was reduced in AIS compared to normal subjects (7% less). Frontal shoulder, pelvis, and hip motion and transversal hip motion were reduced in scoliosis patients (respectively, 21, 27, 28, and 22% less). The EMG recording during walking showed that the quadratus lumborum, erector spinae, gluteus medius, and semitendinosus muscles contracted during a longer part of the stride in scoliotic patients (46% of the stride) compared with normal subjects (35% of the stride). There was no significant difference between scoliosis groups 1, 2, and 3 for

  7. A software tool for 3D dose verification and analysis

    NASA Astrophysics Data System (ADS)

    Sa'd, M. Al; Graham, J.; Liney, G. P.

    2013-06-01

    The main recent developments in radiotherapy have focused on improved treatment techniques in order to generate further significant improvements in patient prognosis. There is now an internationally recognised need to improve 3D verification of highly conformal radiotherapy treatments. This is because of the very high dose gradients used in modern treatment techniques, which can result in a small error in the spatial dose distribution leading to a serious complication. In order to gain the full benefits of using 3D dosimetric technologies (such as gel dosimetry), it is vital to use 3D evaluation methods and algorithms. We present in this paper a software solution that provides a comprehensive 3D dose evaluation and analysis. The software is applied to gel dosimetry, which is based on magnetic resonance imaging (MRI) as a read-out method. The software can also be used to compare any two dose distributions, such as two distributions planned using different methods of treatment planning systems, or different dose calculation algorithms.

  8. 3D Guided Wave Motion Analysis on Laminated Composites

    NASA Technical Reports Server (NTRS)

    Tian, Zhenhua; Leckey, Cara; Yu, Lingyu

    2013-01-01

    Ultrasonic guided waves have proved useful for structural health monitoring (SHM) and nondestructive evaluation (NDE) due to their ability to propagate long distances with less energy loss compared to bulk waves and due to their sensitivity to small defects in the structure. Analysis of actively transmitted ultrasonic signals has long been used to detect and assess damage. However, there remain many challenging tasks for guided wave based SHM due to the complexity involved with propagating guided waves, especially in the case of composite materials. The multimodal nature of the ultrasonic guided waves complicates the related damage analysis. This paper presents results from parallel 3D elastodynamic finite integration technique (EFIT) simulations used to acquire 3D wave motion in the subject laminated carbon fiber reinforced polymer composites. The acquired 3D wave motion is then analyzed by frequency-wavenumber analysis to study the wave propagation and interaction in the composite laminate. The frequency-wavenumber analysis enables the study of individual modes and visualization of mode conversion. Delamination damage has been incorporated into the EFIT model to generate "damaged" data. The potential for damage detection in laminated composites is discussed in the end.

  9. Visualization and Analysis of 3D Gene Expression Data

    SciTech Connect

    Bethel, E. Wes; Rubel, Oliver; Weber, Gunther H.; Hamann, Bernd; Hagen, Hans

    2007-10-25

    Recent methods for extracting precise measurements ofspatial gene expression patterns from three-dimensional (3D) image dataopens the way for new analysis of the complex gene regulatory networkscontrolling animal development. To support analysis of this novel andhighly complex data we developed PointCloudXplore (PCX), an integratedvisualization framework that supports dedicated multi-modal, physical andinformation visualization views along with algorithms to aid in analyzingthe relationships between gene expression levels. Using PCX, we helpedour science stakeholders to address many questions in 3D gene expressionresearch, e.g., to objectively define spatial pattern boundaries andtemporal profiles of genes and to analyze how mRNA patterns arecontrolled by their regulatory transcription factors.

  10. Advanced computational tools for 3-D seismic analysis

    SciTech Connect

    Barhen, J.; Glover, C.W.; Protopopescu, V.A.

    1996-06-01

    The global objective of this effort is to develop advanced computational tools for 3-D seismic analysis, and test the products using a model dataset developed under the joint aegis of the United States` Society of Exploration Geophysicists (SEG) and the European Association of Exploration Geophysicists (EAEG). The goal is to enhance the value to the oil industry of the SEG/EAEG modeling project, carried out with US Department of Energy (DOE) funding in FY` 93-95. The primary objective of the ORNL Center for Engineering Systems Advanced Research (CESAR) is to spearhead the computational innovations techniques that would enable a revolutionary advance in 3-D seismic analysis. The CESAR effort is carried out in collaboration with world-class domain experts from leading universities, and in close coordination with other national laboratories and oil industry partners.

  11. Advancements in 3D Structural Analysis of Geothermal Systems

    SciTech Connect

    Siler, Drew L; Faulds, James E; Mayhew, Brett; McNamara, David

    2013-06-23

    Robust geothermal activity in the Great Basin, USA is a product of both anomalously high regional heat flow and active fault-controlled extension. Elevated permeability associated with some fault systems provides pathways for circulation of geothermal fluids. Constraining the local-scale 3D geometry of these structures and their roles as fluid flow conduits is crucial in order to mitigate both the costs and risks of geothermal exploration and to identify blind (no surface expression) geothermal resources. Ongoing studies have indicated that much of the robust geothermal activity in the Great Basin is associated with high density faulting at structurally complex fault intersection/interaction areas, such as accommodation/transfer zones between discrete fault systems, step-overs or relay ramps in fault systems, intersection zones between faults with different strikes or different senses of slip, and horse-tailing fault terminations. These conceptualized models are crucial for locating and characterizing geothermal systems in a regional context. At the local scale, however, pinpointing drilling targets and characterizing resource potential within known or probable geothermal areas requires precise 3D characterization of the system. Employing a variety of surface and subsurface data sets, we have conducted detailed 3D geologic analyses of two Great Basin geothermal systems. Using EarthVision (Dynamic Graphics Inc., Alameda, CA) we constructed 3D geologic models of both the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These 3D models allow spatial comparison of disparate data sets in 3D and are the basis for quantitative structural analyses that can aid geothermal resource assessment and be used to pinpoint discrete drilling targets. The relatively abundant data set at Brady’s, ~80 km NE of Reno, NV, includes 24 wells with lithologies interpreted from careful analysis of cuttings and core, a 1

  12. Beam Optics Analysis - An Advanced 3D Trajectory Code

    SciTech Connect

    Ives, R. Lawrence; Bui, Thuc; Vogler, William; Neilson, Jeff; Read, Mike; Shephard, Mark; Bauer, Andrew; Datta, Dibyendu; Beal, Mark

    2006-01-03

    Calabazas Creek Research, Inc. has completed initial development of an advanced, 3D program for modeling electron trajectories in electromagnetic fields. The code is being used to design complex guns and collectors. Beam Optics Analysis (BOA) is a fully relativistic, charged particle code using adaptive, finite element meshing. Geometrical input is imported from CAD programs generating ACIS-formatted files. Parametric data is inputted using an intuitive, graphical user interface (GUI), which also provides control of convergence, accuracy, and post processing. The program includes a magnetic field solver, and magnetic information can be imported from Maxwell 2D/3D and other programs. The program supports thermionic emission and injected beams. Secondary electron emission is also supported, including multiple generations. Work on field emission is in progress as well as implementation of computer optimization of both the geometry and operating parameters. The principle features of the program and its capabilities are presented.

  13. Uncertainty Analysis for RELAP5-3D

    SciTech Connect

    Aaron J. Pawel; Dr. George L. Mesina

    2011-08-01

    In its current state, RELAP5-3D is a 'best-estimate' code; it is one of our most reliable programs for modeling what occurs within reactor systems in transients from given initial conditions. This code, however, remains an estimator. A statistical analysis has been performed that begins to lay the foundation for a full uncertainty analysis. By varying the inputs over assumed probability density functions, the output parameters were shown to vary. Using such statistical tools as means, variances, and tolerance intervals, a picture of how uncertain the results are based on the uncertainty of the inputs has been obtained.

  14. Breast tumor angiogenesis analysis using 3D power Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Chang, Ruey-Feng; Huang, Sheng-Fang; Lee, Yu-Hau; Chen, Dar-Ren; Moon, Woo Kyung

    2006-03-01

    Angiogenesis is the process that correlates to tumor growth, invasion, and metastasis. Breast cancer angiogenesis has been the most extensively studied and now serves as a paradigm for understanding the biology of angiogenesis and its effects on tumor outcome and patient prognosis. Most studies on characterization of angiogenesis focus on pixel/voxel counts more than morphological analysis. Nevertheless, in cancer, the blood flow is greatly affected by the morphological changes, such as the number of vessels, branching pattern, length, and diameter. This paper presents a computer-aided diagnostic (CAD) system that can quantify vascular morphology using 3-D power Doppler ultrasound (US) on breast tumors. We propose a scheme to extract the morphological information from angiography and to relate them to tumor diagnosis outcome. At first, a 3-D thinning algorithm helps narrow down the vessels into their skeletons. The measurements of vascular morphology significantly rely on the traversing of the vascular trees produced from skeletons. Our study of 3-D assessment of vascular morphological features regards vessel count, length, bifurcation, and diameter of vessels. Investigations into 221 solid breast tumors including 110 benign and 111 malignant cases, the p values using the Student's t-test for all features are less than 0.05 indicating that the proposed features are deemed statistically significant. Our scheme focuses on the vascular architecture without involving the technique of tumor segmentation. The results show that the proposed method is feasible, and have a good agreement with the diagnosis of the pathologists.

  15. USM3D Analysis of Low Boom Configuration

    NASA Technical Reports Server (NTRS)

    Carter, Melissa B.; Campbell, Richard L.; Nayani, Sudheer N.

    2011-01-01

    In the past few years considerable improvement was made in NASA's in house boom prediction capability. As part of this improved capability, the USM3D Navier-Stokes flow solver, when combined with a suitable unstructured grid, went from accurately predicting boom signatures at 1 body length to 10 body lengths. Since that time, the research emphasis has shifted from analysis to the design of supersonic configurations with boom signature mitigation In order to design an aircraft, the techniques for accurately predicting boom and drag need to be determined. This paper compares CFD results with the wind tunnel experimental results conducted on a Gulfstream reduced boom and drag configuration. Two different wind-tunnel models were designed and tested for drag and boom data. The goal of this study was to assess USM3D capability for predicting both boom and drag characteristics. Overall, USM3D coupled with a grid that was sheared and stretched was able to reasonably predict boom signature. The computational drag polar matched the experimental results for a lift coefficient above 0.1 despite some mismatch in the predicted lift-curve slope.

  16. Estimation of spatial-temporal gait parameters using a low-cost ultrasonic motion analysis system.

    PubMed

    Qi, Yongbin; Soh, Cheong Boon; Gunawan, Erry; Low, Kay-Soon; Thomas, Rijil

    2014-08-20

    In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.

  17. Estimation of Spatial-Temporal Gait Parameters Using a Low-Cost Ultrasonic Motion Analysis System

    PubMed Central

    Qi, Yongbin; Soh, Cheong Boon; Gunawan, Erry; Low, Kay-Soon; Thomas, Rijil

    2014-01-01

    In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications. PMID:25140636

  18. Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors.

    PubMed

    Fantozzi, Silvia; Giovanardi, Andrea; Borra, Davide; Gatta, Giorgio

    2015-01-01

    Walking is one of the fundamental motor tasks executed during aquatic therapy. Previous kinematics analyses conducted using waterproofed video cameras were limited to the sagittal plane and to only one or two consecutive steps. Furthermore, the set-up and post-processing are time-consuming and thus do not allow a prompt assessment of the correct execution of the movements during the aquatic session therapy. The aim of the present study was to estimate the 3D joint kinematics of the lower limbs and thorax-pelvis joints in sagittal and frontal planes during underwater walking using wearable inertial and magnetic sensors. Eleven healthy adults were measured during walking both in shallow water and in dry-land conditions. Eight wearable inertial and magnetic sensors were inserted in waterproofed boxes and fixed to the body segments by means of elastic modular bands. A validated protocol (Outwalk) was used. Gait cycles were automatically segmented and selected if relevant intraclass correlation coefficients values were higher than 0.75. A total of 704 gait cycles for the lower limb joints were normalized in time and averaged to obtain the mean cycle of each joint, among participants. The mean speed in water was 40% lower than that of the dry-land condition. Longer stride duration and shorter stride distance were found in the underwater walking. In the sagittal plane, the knee was more flexed (≈ 23°) and the ankle more dorsiflexed (≈ 9°) at heel strike, and the hip was more flexed at toe-off (≈ 13°) in water than on land. On the frontal plane in the underwater walking, smoother joint angle patterns were observed for thorax-pelvis and hip, and ankle was more inversed at toe-off (≈ 7°) and showed a more inversed mean value (≈ 7°). The results were mainly explained by the effect of the speed in the water as supported by the linear mixed models analysis performed. Thus, it seemed that the combination of speed and environment triggered modifications in the

  19. Gait Kinematic Analysis in Water Using Wearable Inertial Magnetic Sensors

    PubMed Central

    Fantozzi, Silvia; Giovanardi, Andrea; Borra, Davide; Gatta, Giorgio

    2015-01-01

    Walking is one of the fundamental motor tasks executed during aquatic therapy. Previous kinematics analyses conducted using waterproofed video cameras were limited to the sagittal plane and to only one or two consecutive steps. Furthermore, the set-up and post-processing are time-consuming and thus do not allow a prompt assessment of the correct execution of the movements during the aquatic session therapy. The aim of the present study was to estimate the 3D joint kinematics of the lower limbs and thorax-pelvis joints in sagittal and frontal planes during underwater walking using wearable inertial and magnetic sensors. Eleven healthy adults were measured during walking both in shallow water and in dry-land conditions. Eight wearable inertial and magnetic sensors were inserted in waterproofed boxes and fixed to the body segments by means of elastic modular bands. A validated protocol (Outwalk) was used. Gait cycles were automatically segmented and selected if relevant intraclass correlation coefficients values were higher than 0.75. A total of 704 gait cycles for the lower limb joints were normalized in time and averaged to obtain the mean cycle of each joint, among participants. The mean speed in water was 40% lower than that of the dry-land condition. Longer stride duration and shorter stride distance were found in the underwater walking. In the sagittal plane, the knee was more flexed (≈ 23°) and the ankle more dorsiflexed (≈ 9°) at heel strike, and the hip was more flexed at toe-off (≈ 13°) in water than on land. On the frontal plane in the underwater walking, smoother joint angle patterns were observed for thorax-pelvis and hip, and ankle was more inversed at toe-off (≈ 7°) and showed a more inversed mean value (≈ 7°). The results were mainly explained by the effect of the speed in the water as supported by the linear mixed models analysis performed. Thus, it seemed that the combination of speed and environment triggered modifications in the

  20. Gait analysis in prosthetics: opinions, ideas and conclusions.

    PubMed

    Rietman, J S; Postema, K; Geertzen, J H B

    2002-04-01

    A review was performed of the literature of the last eleven years (1990-2000) with the topic: "clinical use of instrumented gait analysis in patients wearing a prosthesis of the lower limb". To this end a literature search was performed in Embase, Medline and Recal. Forty-five (45) articles were identified for study from which 34 were reviewed. The reviews were divided into five subtopics: 1) adaptive strategies in gait (12 studies); 2) the influence of different parts of the prosthesis on gait (12 studies); 3) pressure measurements in the socket in gait studies (4 studies); 4) the influence of the mass of the prostheses on gait (5 studies); 5) energy considerations in gait (2 studies). A considerable part of the studies concerned the adaptive strategies of the amputee in walking and running and the evaluation of different prosthetic feet. All aspects and outcomes were reviewed concerning the clinical relevance.

  1. Optical 3D shape, surface, and material analysis

    NASA Astrophysics Data System (ADS)

    Tiziani, Hans J.

    2001-06-01

    Different techniques are available for macro- and micro- topometry. The methods are basically known but their industrial implementation requires robust measuring systems, where calibration is an important necessity. Different techniques will be presented. New elements such as liquid crystal displays and micromirror devices are available leading to new applications to be discussed. Combinative methods and integration in measuring systems becomes interesting. The state of the art and new developments will be presented. Together with calibration for 3D-shock or vibration analysis an object shape measuring systems will be directly combined with a vibration measuring system.

  2. On 3D inelastic analysis methods for hot section components

    NASA Technical Reports Server (NTRS)

    Mcknight, R. L.; Chen, P. C.; Dame, L. T.; Holt, R. V.; Huang, H.; Hartle, M.; Gellin, S.; Allen, D. H.; Haisler, W. E.

    1986-01-01

    Accomplishments are described for the 2-year program, to develop advanced 3-D inelastic structural stress analysis methods and solution strategies for more accurate and cost effective analysis of combustors, turbine blades and vanes. The approach was to develop a matrix of formulation elements and constitutive models. Three constitutive models were developed in conjunction with optimized iterating techniques, accelerators, and convergence criteria within a framework of dynamic time incrementing. Three formulations models were developed; an eight-noded mid-surface shell element, a nine-noded mid-surface shell element and a twenty-noded isoparametric solid element. A separate computer program was developed for each combination of constitutive model-formulation model. Each program provides a functional stand alone capability for performing cyclic nonlinear structural analysis. In addition, the analysis capabilities incorporated into each program can be abstracted in subroutine form for incorporation into other codes or to form new combinations.

  3. The 3D inelastic analysis methods for hot section components

    NASA Technical Reports Server (NTRS)

    Mcknight, R. L.; Maffeo, R. J.; Tipton, M. T.; Weber, G.

    1992-01-01

    A two-year program to develop advanced 3D inelastic structural stress analysis methods and solution strategies for more accurate and cost effective analysis of combustors, turbine blades, and vanes is described. The approach was to develop a matrix of formulation elements and constitutive models. Three constitutive models were developed in conjunction with optimized iterating techniques, accelerators, and convergence criteria within a framework of dynamic time incrementing. Three formulation models were developed: an eight-noded midsurface shell element; a nine-noded midsurface shell element; and a twenty-noded isoparametric solid element. A separate computer program has been developed for each combination of constitutive model-formulation model. Each program provides a functional stand alone capability for performing cyclic nonlinear structural analysis. In addition, the analysis capabilities incorporated into each program can be abstracted in subroutine form for incorporation into other codes or to form new combinations.

  4. The development of a 3D risk analysis method.

    PubMed

    I, Yet-Pole; Cheng, Te-Lung

    2008-05-01

    Much attention has been paid to the quantitative risk analysis (QRA) research in recent years due to more and more severe disasters that have happened in the process industries. Owing to its calculation complexity, very few software, such as SAFETI, can really make the risk presentation meet the practice requirements. However, the traditional risk presentation method, like the individual risk contour in SAFETI, is mainly based on the consequence analysis results of dispersion modeling, which usually assumes that the vapor cloud disperses over a constant ground roughness on a flat terrain with no obstructions and concentration fluctuations, which is quite different from the real situations of a chemical process plant. All these models usually over-predict the hazardous regions in order to maintain their conservativeness, which also increases the uncertainty of the simulation results. On the other hand, a more rigorous model such as the computational fluid dynamics (CFD) model can resolve the previous limitations; however, it cannot resolve the complexity of risk calculations. In this research, a conceptual three-dimensional (3D) risk calculation method was proposed via the combination of results of a series of CFD simulations with some post-processing procedures to obtain the 3D individual risk iso-surfaces. It is believed that such technique will not only be limited to risk analysis at ground level, but also be extended into aerial, submarine, or space risk analyses in the near future.

  5. Somatotyping using 3D anthropometry: a cluster analysis.

    PubMed

    Olds, Tim; Daniell, Nathan; Petkov, John; David Stewart, Arthur

    2013-01-01

    Somatotyping is the quantification of human body shape, independent of body size. Hitherto, somatotyping (including the most popular method, the Heath-Carter system) has been based on subjective visual ratings, sometimes supported by surface anthropometry. This study used data derived from three-dimensional (3D) whole-body scans as inputs for cluster analysis to objectively derive clusters of similar body shapes. Twenty-nine dimensions normalised for body size were measured on a purposive sample of 301 adults aged 17-56 years who had been scanned using a Vitus Smart laser scanner. K-means Cluster Analysis with v-fold cross-validation was used to determine shape clusters. Three male and three female clusters emerged, and were visualised using those scans closest to the cluster centroid and a caricature defined by doubling the difference between the average scan and the cluster centroid. The male clusters were decidedly endomorphic (high fatness), ectomorphic (high linearity), and endo-mesomorphic (a mixture of fatness and muscularity). The female clusters were clearly endomorphic, ectomorphic, and the ecto-mesomorphic (a mixture of linearity and muscularity). An objective shape quantification procedure combining 3D scanning and cluster analysis yielded shape clusters strikingly similar to traditional somatotyping.

  6. A 3D Musculo-Mechanical Model of the Salamander for the Study of Different Gaits and Modes of Locomotion.

    PubMed

    Harischandra, Nalin; Cabelguen, Jean-Marie; Ekeberg, Orjan

    2010-01-01

    Computer simulation has been used to investigate several aspects of locomotion in salamanders. Here we introduce a three-dimensional forward dynamics mechanical model of a salamander, with physically realistic weight and size parameters. Movements of the four limbs and of the trunk and tail are generated by sets of linearly modeled skeletal muscles. In this study, activation of these muscles were driven by prescribed neural output patterns. The model was successfully used to mimic locomotion on level ground and in water. We compare the walking gait where a wave of activity in the axial muscles travels between the girdles, with the trotting gait in simulations using the musculo-mechanical model. In a separate experiment, the model is used to compare different strategies for turning while stepping; either by bending the trunk or by using side-stepping in the front legs. We found that for turning, the use of side-stepping alone or in combination with trunk bending, was more effective than the use of trunk bending alone. We conclude that the musculo-mechanical model described here together with a proper neural controller is useful for neuro-physiological experiments in silico.

  7. 3D morphometric analysis of human fetal cerebellar development.

    PubMed

    Scott, Julia A; Hamzelou, Kia S; Rajagopalan, Vidya; Habas, Piotr A; Kim, Kio; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2012-09-01

    To date, growth of the human fetal cerebellum has been estimated primarily from linear measurements from ultrasound and 2D magnetic resonance imaging (MRI). In this study, we use 3D analytical methods to develop normative growth trajectories for the cerebellum in utero. We measured cerebellar volume, linear dimensions, and local surface curvature from 3D reconstructed MRI of the human fetal brain (N = 46). We found that cerebellar volume increased approximately 7-fold from 20 to 31 gestational weeks. The better fit of the exponential curve (R (2) = 0.96) compared to the linear curve (R (2) = 0.92) indicated acceleration in growth. Within-subject cerebellar and cerebral volumes were highly correlated (R (2) = 0.94), though the cerebellar percentage of total brain volume increased from approximately 2.4% to 3.7% (R (2) = 0.63). Right and left hemispheric volumes did not significantly differ. Transcerebellar diameter, vermal height, and vermal anterior to posterior diameter increased significantly at constant rates. From the local curvature analysis, we found that expansion along the inferior and superior aspects of the hemispheres resulted in decreased convexity, which is likely due to the physical constraints of the dura surrounding the cerebellum and the adjacent brainstem. The paired decrease in convexity along the inferior vermis and increased convexity of the medial hemisphere represents development of the paravermian fissure, which becomes more visible during this period. In this 3D morphometric analysis of the human fetal cerebellum, we have shown that cerebellar growth is accelerating at a greater pace than the cerebrum and described how cerebellar growth impacts the shape of the structure.

  8. 3D Morphometric Analysis of Human Fetal Cerebellar Development

    PubMed Central

    Hamzelou, Kia S.; Rajagopalan, Vidya; Habas, Piotr A.; Kim, Kio; Barkovich, A. James; Glenn, Orit A.; Studholme, Colin

    2012-01-01

    To date, growth of the human fetal cerebellum has been estimated primarily from linear measurements from ultrasound and 2D magnetic resonance imaging (MRI). In this study, we use 3D analytical methods to develop normative growth trajectories for the cerebellum in utero. We measured cerebellar volume, linear dimensions, and local surface curvature from 3D reconstructed MRI of the human fetal brain (N = 46). We found that cerebellar volume increased approximately 7-fold from 20 to 31 gestational weeks. The better fit of the exponential curve (R2 = 0.96) compared to the linear curve (R2 = 0.92) indicated acceleration in growth. Within-subject cerebellar and cerebral volumes were highly correlated (R2 = 0.94), though the cerebellar percentage of total brain volume increased from approximately 2.4% to 3.7% (R2 = 0.63). Right and left hemispheric volumes did not significantly differ. Transcerebellar diameter, vermal height, and vermal anterior to posterior diameter increased significantly at constant rates. From the local curvature analysis, we found that expansion along the inferior and superior aspects of the hemispheres resulted in decreased convexity, which is likely due to the physical constraints of the dura surrounding the cerebellum and the adjacent brainstem. The paired decrease in convexity along the inferior vermis and increased convexity of the medial hemisphere represents development of the paravermian fissure, which becomes more visible during this period. In this 3D morphometric analysis of the human fetal cerebellum, we have shown that cerebellar growth is accelerating at a greater pace than the cerebrum and described how cerebellar growth impacts the shape of the structure. PMID:22198870

  9. Computational analysis of flow in 3D propulsive transition ducts

    NASA Technical Reports Server (NTRS)

    Sepri, Paavo

    1990-01-01

    A numerical analysis of fully three dimensional, statistically steady flows in propulsive transition ducts being considered for use in future aircraft of higher maneuverability is investigated. The purpose of the transition duct is to convert axisymmetric flow from conventional propulsion systems to that of a rectangular geometry of high aspect ratio. In an optimal design, the transition duct would be of minimal length in order to reduce the weight penalty, while the geometrical change would be gradual enough to avoid detrimental flow perturbations. Recent experiments conducted at the Propulsion Aerodynamics Branch have indicated that thrust losses in ducts of superelliptic cross-section can be surprisingly low, even if flow separation occurs near the divergent walls. In order to address the objective of developing a rational design procedure for optimal transition ducts, it is necessary to have available a reliable computational tool for the analysis of flows achieved in a sequence of configurations. Current CFD efforts involving complicated geometries usually must contend with two separate but interactive aspects: namely, grid generation and flow solution. The first two avenues of the present investigation were comprised of suitable grid generation for a class of transition ducts of superelliptic cross-section, and the subsequent application of the flow solver PAB3D to this geometry. The code, PAB3D, was developed as a comprehensive tool for the solution of both internal and external high speed flows. The third avenue of investigation has involved analytical formulations to aid in the understanding of the nature of duct flows, and also to provide a basis of comparison for subsequent numerical solutions. Numerical results to date include the generation of two preliminary grid systems for duct flows, and the initial application of PAB3D to the corresponding geometries, which are of the class tested experimentally.

  10. Automated Gait Analysis Through Hues and Areas (AGATHA): A Method to Characterize the Spatiotemporal Pattern of Rat Gait.

    PubMed

    Kloefkorn, Heidi E; Pettengill, Travis R; Turner, Sara M F; Streeter, Kristi A; Gonzalez-Rothi, Elisa J; Fuller, David D; Allen, Kyle D

    2017-03-01

    While rodent gait analysis can quantify the behavioral consequences of disease, significant methodological differences exist between analysis platforms and little validation has been performed to understand or mitigate these sources of variance. By providing the algorithms used to quantify gait, open-source gait analysis software can be validated and used to explore methodological differences. Our group is introducing, for the first time, a fully-automated, open-source method for the characterization of rodent spatiotemporal gait patterns, termed Automated Gait Analysis Through Hues and Areas (AGATHA). This study describes how AGATHA identifies gait events, validates AGATHA relative to manual digitization methods, and utilizes AGATHA to detect gait compensations in orthopaedic and spinal cord injury models. To validate AGATHA against manual digitization, results from videos of rodent gait, recorded at 1000 frames per second (fps), were compared. To assess one common source of variance (the effects of video frame rate), these 1000 fps videos were re-sampled to mimic several lower fps and compared again. While spatial variables were indistinguishable between AGATHA and manual digitization, low video frame rates resulted in temporal errors for both methods. At frame rates over 125 fps, AGATHA achieved a comparable accuracy and precision to manual digitization for all gait variables. Moreover, AGATHA detected unique gait changes in each injury model. These data demonstrate AGATHA is an accurate and precise platform for the analysis of rodent spatiotemporal gait patterns.

  11. Uncertainty Analysis of RELAP5-3D

    SciTech Connect

    Alexandra E Gertman; Dr. George L Mesina

    2012-07-01

    As world-wide energy consumption continues to increase, so does the demand for the use of alternative energy sources, such as Nuclear Energy. Nuclear Power Plants currently supply over 370 gigawatts of electricity, and more than 60 new nuclear reactors have been commissioned by 15 different countries. The primary concern for Nuclear Power Plant operation and lisencing has been safety. The safety of the operation of Nuclear Power Plants is no simple matter- it involves the training of operators, design of the reactor, as well as equipment and design upgrades throughout the lifetime of the reactor, etc. To safely design, operate, and understand nuclear power plants, industry and government alike have relied upon the use of best-estimate simulation codes, which allow for an accurate model of any given plant to be created with well-defined margins of safety. The most widely used of these best-estimate simulation codes in the Nuclear Power industry is RELAP5-3D. Our project focused on improving the modeling capabilities of RELAP5-3D by developing uncertainty estimates for its calculations. This work involved analyzing high, medium, and low ranked phenomena from an INL PIRT on a small break Loss-Of-Coolant Accident as wall as an analysis of a large break Loss-Of- Coolant Accident. Statistical analyses were performed using correlation coefficients. To perform the studies, computer programs were written that modify a template RELAP5 input deck to produce one deck for each combination of key input parameters. Python scripting enabled the running of the generated input files with RELAP5-3D on INL’s massively parallel cluster system. Data from the studies was collected and analyzed with SAS. A summary of the results of our studies are presented.

  12. Superior functional outcome after femoral derotation osteotomy according to gait analysis in cerebral palsy.

    PubMed

    Niklasch, M; Dreher, T; Döderlein, L; Wolf, S I; Ziegler, K; Brunner, R; Rutz, E

    2015-01-01

    The femoral derotation osteotomy (FDO) is seen as the golden standard treatment in children with cerebral palsy and internal rotation gait. Variable outcomes with cases of over- and undercorrection mainly in the less involved patients have been reported. The determination of the amount of derotation is still inconsistent. 138 patients (age: 11 (± 3.3) years) with cerebral palsy and internal rotation gait were examined pre- and 1 year postoperatively after distal or proximal FDO, using standardized clinical examination and 3D gait analysis. Three groups were defined retrospectively depending on the amount of derotation in relation to the mean hip rotation in stance (MHR) during gait analysis: Group A (derotation angle > MHR + 10°), Group B (derotation angle = MHR ± 10°), Group C (derotation angle gait analysis compared with clinical examination.

  13. Fractal and Multifractal Analysis of Human Gait

    NASA Astrophysics Data System (ADS)

    Muñoz-Diosdado, A.; del Río Correa, J. L.; Angulo-Brown, F.

    2003-09-01

    We carried out a fractal and multifractal analysis of human gait time series of young and old individuals, and adults with three illnesses that affect the march: The Parkinson's and Huntington's diseases and the amyotrophic lateral sclerosis (ALS). We obtained cumulative plots of events, the correlation function, the Hurst exponent and the Higuchi's fractal dimension of these time series and found that these fractal markers could be a factor to characterize the march, since we obtained different values of these quantities for youths and adults and they are different also for healthy and ill persons and the most anomalous values belong to ill persons. In other physiological signals there is complexity lost related with the age and the illness, in the case of the march the opposite occurs. The multifractal analysis could be also a useful tool to understand the dynamics of these and other complex systems.

  14. Comparative visual analysis of 3D urban wind simulations

    NASA Astrophysics Data System (ADS)

    Röber, Niklas; Salim, Mohamed; Grawe, David; Leitl, Bernd; Böttinger, Michael; Schlünzen, Heinke

    2016-04-01

    Climate simulations are conducted in large quantity for a variety of different applications. Many of these simulations focus on global developments and study the Earth's climate system using a coupled atmosphere ocean model. Other simulations are performed on much smaller regional scales, to study very small fine grained climatic effects. These microscale climate simulations pose similar, yet also different, challenges for the visualization and the analysis of the simulation data. Modern interactive visualization and data analysis techniques are very powerful tools to assist the researcher in answering and communicating complex research questions. This presentation discusses comparative visualization for several different wind simulations, which were created using the microscale climate model MITRAS. The simulations differ in wind direction and speed, but are all centered on the same simulation domain: An area of Hamburg-Wilhelmsburg that hosted the IGA/IBA exhibition in 2013. The experiments contain a scenario case to analyze the effects of single buildings, as well as examine the impact of the Coriolis force within the simulation. The scenario case is additionally compared with real measurements from a wind tunnel experiment to ascertain the accuracy of the simulation and the model itself. We also compare different approaches for tree modeling and evaluate the stability of the model. In this presentation, we describe not only our workflow to efficiently and effectively visualize microscale climate simulation data using common 3D visualization and data analysis techniques, but also discuss how to compare variations of a simulation and how to highlight the subtle differences in between them. For the visualizations we use a range of different 3D tools that feature techniques for statistical data analysis, data selection, as well as linking and brushing.

  15. [A modular method for automated evaluation of gait analysis data].

    PubMed

    Loose, T; Malberg, H; Mikut, R; Dieterle, J; Schablowski, M; Wolf, S; Abel, R; Döderlein, L; Rupp, R

    2002-01-01

    A modular methodology for automated gait data evaluation: The aim of Instrumented Gait Analysis is to measure data such as joint kinematics or kinetics during gait in a quantitative way. The data evaluation for clinical purposes is often performed by experienced physicians (diagnosis of specific motion dysfunction, planning and validation of therapy). Due to subjective evaluation and complexity of the pathologies, there exists no objective, standardized data analysis method for these tasks. This article covers the development of a modular, computer-based methodology to quantify the degree of pathological gait in comparison to normal behavior, as well as to automatically search for interpretable gait abnormalities and to visualize the results. The outcomes are demonstrated with two different patient groups.

  16. Colossal Tooling Design: 3D Simulation for Ergonomic Analysis

    NASA Technical Reports Server (NTRS)

    Hunter, Steve L.; Dischinger, Charles; Thomas, Robert E.; Babai, Majid

    2003-01-01

    The application of high-level 3D simulation software to the design phase of colossal mandrel tooling for composite aerospace fuel tanks was accomplished to discover and resolve safety and human engineering problems. The analyses were conducted to determine safety, ergonomic and human engineering aspects of the disassembly process of the fuel tank composite shell mandrel. Three-dimensional graphics high-level software, incorporating various ergonomic analysis algorithms, was utilized to determine if the process was within safety and health boundaries for the workers carrying out these tasks. In addition, the graphical software was extremely helpful in the identification of material handling equipment and devices for the mandrel tooling assembly/disassembly process.

  17. Gait Analysis Methods for Rodent Models of Osteoarthritis

    PubMed Central

    Jacobs, Brittany Y.; Kloefkorn, Heidi E.; Allen, Kyle D.

    2014-01-01

    Patients with osteoarthritis (OA) primarily seek treatment due to pain and disability, yet the primary endpoints for rodent OA models tend to be histological measures of joint destruction. The discrepancy between clinical and preclinical evaluations is problematic, given that radiographic evidence of OA in humans does not always correlate to the severity of patient-reported symptoms. Recent advances in behavioral analyses have provided new methods to evaluate disease sequelae in rodents. Of particular relevance to rodent OA models are methods to assess rodent gait. While obvious differences exist between quadrupedal and bipedal gait sequences, the gait abnormalities seen in humans and in rodent OA models reflect similar compensatory behaviors that protect an injured limb from loading. The purpose of this review is to describe these compensations and current methods used to assess rodent gait characteristics, while detailing important considerations for the selection of gait analysis methods in rodent OA models. PMID:25160712

  18. Gait analysis methods for rodent models of osteoarthritis.

    PubMed

    Jacobs, Brittany Y; Kloefkorn, Heidi E; Allen, Kyle D

    2014-10-01

    Patients with osteoarthritis (OA) primarily seek treatment due to pain and disability, yet the primary endpoints for rodent OA models tend to be histological measures of joint destruction. The discrepancy between clinical and preclinical evaluations is problematic, given that radiographic evidence of OA in humans does not always correlate to the severity of patient-reported symptoms. Recent advances in behavioral analyses have provided new methods to evaluate disease sequelae in rodents. Of particular relevance to rodent OA models are methods to assess rodent gait. While obvious differences exist between quadrupedal and bipedal gait sequences, the gait abnormalities seen in humans and in rodent OA models reflect similar compensatory behaviors that protect an injured limb from loading. The purpose of this review is to describe these compensations and current methods used to assess rodent gait characteristics, while detailing important considerations for the selection of gait analysis methods in rodent OA models.

  19. Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review.

    PubMed

    Chen, Shanshan; Lach, John; Lo, Benny; Yang, Guang-Zhong

    2016-11-01

    After decades of evolution, measuring instruments for quantitative gait analysis have become an important clinical tool for assessing pathologies manifested by gait abnormalities. However, such instruments tend to be expensive and require expert operation and maintenance besides their high cost, thus limiting them to only a small number of specialized centers. Consequently, gait analysis in most clinics today still relies on observation-based assessment. Recent advances in wearable sensors, especially inertial body sensors, have opened up a promising future for gait analysis. Not only can these sensors be more easily adopted in clinical diagnosis and treatment procedures than their current counterparts, but they can also monitor gait continuously outside clinics - hence providing seamless patient analysis from clinics to free-living environments. The purpose of this paper is to provide a systematic review of current techniques for quantitative gait analysis and to propose key metrics for evaluating both existing and emerging methods for qualifying the gait features extracted from wearable sensors. It aims to highlight key advances in this rapidly evolving research field and outline potential future directions for both research and clinical applications.

  20. Optimal markers' placement on the thorax for clinical gait analysis.

    PubMed

    Armand, Stéphane; Sangeux, Morgan; Baker, Richard

    2014-01-01

    Although, several thorax models have been proposed for clinical gait analysis, none has received widespread acceptance nor been subject to any extensive validation work, especially for the marker set to use. The aim of this study was thus to determine the optimal and minimal makers' placement on the thorax for clinical gait analysis. Ten healthy subjects have performed a series of movements (arm, head, trunk) with large amplitude during walking. Reflective markers were taped on the thorax (C7, T2, T4, T6, T8, T10, T12, sternum, clavicles and ribs) and their 3D positions were captured with an opto-electronic system. Each combination of 3 markers has been tested. The global error of each model was computed with the estimated position of the markers considering the thorax segment as a solid segment. Two families of marker sets were identified with the lowest error. The first family was composed by two anterior and one posterior marker on the thorax (incisura jugularis (IJ), xiphoid process, and T8). The second family was composed by two posterior and one anterior maker (IJ, T2 and T8 or T10). Even, if these two families of marker sets presented a similar error for marker position, the angles obtained from these marker sets showed large differences especially for the axial rotation movement of the trunk (up to 40.1°). The optimal and minimal maker set identified with a variety of large movements of the trunk, head and arms was IJ, T2 and T8 or T10.

  1. 3D Image Analysis of Geomaterials using Confocal Microscopy

    NASA Astrophysics Data System (ADS)

    Mulukutla, G.; Proussevitch, A.; Sahagian, D.

    2009-05-01

    Confocal microscopy is one of the most significant advances in optical microscopy of the last century. It is widely used in biological sciences but its application to geomaterials lingers due to a number of technical problems. Potentially the technique can perform non-invasive testing on a laser illuminated sample that fluoresces using a unique optical sectioning capability that rejects out-of-focus light reaching the confocal aperture. Fluorescence in geomaterials is commonly induced using epoxy doped with a fluorochrome that is impregnated into the sample to enable discrimination of various features such as void space or material boundaries. However, for many geomaterials, this method cannot be used because they do not naturally fluoresce and because epoxy cannot be impregnated into inaccessible parts of the sample due to lack of permeability. As a result, the confocal images of most geomaterials that have not been pre-processed with extensive sample preparation techniques are of poor quality and lack the necessary image and edge contrast necessary to apply any commonly used segmentation techniques to conduct any quantitative study of its features such as vesicularity, internal structure, etc. In our present work, we are developing a methodology to conduct a quantitative 3D analysis of images of geomaterials collected using a confocal microscope with minimal amount of prior sample preparation and no addition of fluorescence. Two sample geomaterials, a volcanic melt sample and a crystal chip containing fluid inclusions are used to assess the feasibility of the method. A step-by-step process of image analysis includes application of image filtration to enhance the edges or material interfaces and is based on two segmentation techniques: geodesic active contours and region competition. Both techniques have been applied extensively to the analysis of medical MRI images to segment anatomical structures. Preliminary analysis suggests that there is distortion in the

  2. Structural analysis of tropical cyclone using INSAT-3D observations

    NASA Astrophysics Data System (ADS)

    Jaiswal, Neeru; Kishtawal, C. M.

    2016-05-01

    The continuous observations from visible and thermal infrared (TIR) channels of geostationary satellites are highly useful for obtaining the features associated with the shape and dynamics of cloud structures within the tropical cyclones (TCs). As TC develops from an unstructured cloud cluster and intensifies, the cloud structures become more axisymmetric around the centre of the TC. To better understand the structure of TC during different stages of its evolution i.e. from its cyclogenesis to maturity and dissipation, the continuous satellite observations plays a key role. The high spatial and temporal resolution observations from geostationary satellites are very useful in order to analyze the cloud organization during the cyclogenesis. The gradient of the brightness temperatures measures the level of symmetry of each structure, which characterizes the degree of cloud organization of the TC. In the present work, the structural analysis of TC during its life period using the observations from Indian geostationary satellite INSAT-3D has been discussed. The visible and TIR observations from INSAT-3D satellite were used to fix the center position of the cyclone which is an input for the cyclone track and intensity prediction models. This data is also used to estimate the intensity of cyclone in the advanced Dvorak technique (ADT), and in the estimation of radius of maximum winds (Rmax) of TC which is an essential input parameter for the prediction of storm surge associated to the cyclones. The different patterns of cloud structure during the intensification stage, eye-wall formation and dissipation have been discussed. The early identification of these features helps in predicting the rapid intensification of TC which in turn improves the intensity predictions.

  3. Analysis and dynamic 3D visualization of cerebral blood flow combining 3D and 4D MR image sequences

    NASA Astrophysics Data System (ADS)

    Forkert, Nils Daniel; Säring, Dennis; Fiehler, Jens; Illies, Till; Möller, Dietmar; Handels, Heinz

    2009-02-01

    In this paper we present a method for the dynamic visualization of cerebral blood flow. Spatio-temporal 4D magnetic resonance angiography (MRA) image datasets and 3D MRA datasets with high spatial resolution were acquired for the analysis of arteriovenous malformations (AVMs). One of the main tasks is the combination of the information of the 3D and 4D MRA image sequences. Initially, in the 3D MRA dataset the vessel system is segmented and a 3D surface model is generated. Then, temporal intensity curves are analyzed voxelwise in the 4D MRA image sequences. A curve fitting of the temporal intensity curves to a patient individual reference curve is used to extract the bolus arrival times in the 4D MRA sequences. After non-linear registration of both MRA datasets the extracted hemodynamic information is transferred to the surface model where the time points of inflow can be visualized color coded dynamically over time. The dynamic visualizations computed using the curve fitting method for the estimation of the bolus arrival times were rated superior compared to those computed using conventional approaches for bolus arrival time estimation. In summary the procedure suggested allows a dynamic visualization of the individual hemodynamic situation and better understanding during the visual evaluation of cerebral vascular diseases.

  4. 3D Finite Element Analysis of Particle-Reinforced Aluminum

    NASA Technical Reports Server (NTRS)

    Shen, H.; Lissenden, C. J.

    2002-01-01

    Deformation in particle-reinforced aluminum has been simulated using three distinct types of finite element model: a three-dimensional repeating unit cell, a three-dimensional multi-particle model, and two-dimensional multi-particle models. The repeating unit cell model represents a fictitious periodic cubic array of particles. The 3D multi-particle (3D-MP) model represents randomly placed and oriented particles. The 2D generalized plane strain multi-particle models were obtained from planar sections through the 3D-MP model. These models were used to study the tensile macroscopic stress-strain response and the associated stress and strain distributions in an elastoplastic matrix. The results indicate that the 2D model having a particle area fraction equal to the particle representative volume fraction of the 3D models predicted the same macroscopic stress-strain response as the 3D models. However, there are fluctuations in the particle area fraction in a representative volume element. As expected, predictions from 2D models having different particle area fractions do not agree with predictions from 3D models. More importantly, it was found that the microscopic stress and strain distributions from the 2D models do not agree with those from the 3D-MP model. Specifically, the plastic strain distribution predicted by the 2D model is banded along lines inclined at 45 deg from the loading axis while the 3D model prediction is not. Additionally, the triaxial stress and maximum principal stress distributions predicted by 2D and 3D models do not agree. Thus, it appears necessary to use a multi-particle 3D model to accurately predict material responses that depend on local effects, such as strain-to-failure, fracture toughness, and fatigue life.

  5. Biomechanics and analysis of running gait.

    PubMed

    Dugan, Sheila A; Bhat, Krishna P

    2005-08-01

    Physical activity, including running, is important to general health by way of prevention of chronic illnesses and their precursors. To keep runners healthy, it is paramount that one has sound knowledge of the biomechanics of running and assessment of running gait. More so, improving performance in competitive runners is based in sound training and rehabilitation practices that are rooted firmly in biomechanical principles. This article summarized the biomechanics of running and the means with which one can evaluate running gait. The gait assessment techniques for collecting and analyzing kinetic and kinematic data can provide insights into injury prevention and treatment and performance enhancement.

  6. Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements.

    PubMed

    Fradet, Laetitia; Siegel, Johannes; Dahl, Marieke; Alimusaj, Merkur; Wolf, Sebastian I

    2009-01-01

    Insole pressure systems are often more appropriate than force platforms for analysing center of pressure (CoP) as they are more flexible in use and indicate the position of the CoP that characterizes the contact foot/shoe during gait with shoes. However, these systems are typically not synchronized with 3D motion analysis systems. The present paper proposes a direct method that does not require a force platform for synchronizing an insole pressure system with a 3D motion analysis system. The distance separating 24 different CoPs measured optically and their equivalents measured by the insoles and transformed in the global coordinate system did not exceed 2 mm, confirming the suitability of the method proposed. Additionally, during static single limb stance, distances smaller than 7 mm and correlations higher than 0.94 were found between CoP trajectories measured with insoles and force platforms. Similar measurements were performed during gait to illustrate the characteristics of the CoP measured with each system. The distance separating the two CoPs was below 19 mm and the coefficient of correlation above 0.86. The proposed method offers the possibility to conduct new experiments, such as the investigation of proprioception in climbing stairs or in the presence of obstacles.

  7. Analysis of 3D multi-layer microfluidic gradient generator.

    PubMed

    Ha, Jang Ho; Kim, Tae Hyeon; Lee, Jong Min; Ahrberg, Christian D; Chung, Bong Geun

    2017-01-01

    We developed a three-dimensional (3D) simple multi-layer microfluidic gradient generator to create molecular gradients on the centimeter scale with a wide range of flow rates. To create the concentration gradients, a main channel (MC) was orthogonally intersected with vertical side microchannel (SC) in a 3D multi-layer microfluidic device. Through sequential dilution from the SC, a spatial gradient was generated in the MC. Two theoretical models were created to assist in the design of the 3D multi-layer microfluidic gradient generator and to compare its performance against a two-dimensional equivalent. A first mass balance model was used to predict the steady-state concentrations reached, while a second computational fluid dynamic model was employed to predict spatial development of the gradient by considering convective as well as diffusive mass transport. Furthermore, the theoretical simulations were verified through experiments to create molecular gradients in a 3D multi-layer microfluidic gradient generator.

  8. Quantitative analysis of autophagy using advanced 3D fluorescence microscopy.

    PubMed

    Changou, Chun A; Wolfson, Deanna L; Ahluwalia, Balpreet Singh; Bold, Richard J; Kung, Hsing-Jien; Chuang, Frank Y S

    2013-05-03

    Prostate cancer is the leading form of malignancies among men in the U.S. While surgery carries a significant risk of impotence and incontinence, traditional chemotherapeutic approaches have been largely unsuccessful. Hormone therapy is effective at early stage, but often fails with the eventual development of hormone-refractory tumors. We have been interested in developing therapeutics targeting specific metabolic deficiency of tumor cells. We recently showed that prostate tumor cells specifically lack an enzyme (argininosuccinate synthase, or ASS) involved in the synthesis of the amino acid arginine(1). This condition causes the tumor cells to become dependent on exogenous arginine, and they undergo metabolic stress when free arginine is depleted by arginine deiminase (ADI)(1,10). Indeed, we have shown that human prostate cancer cells CWR22Rv1 are effectively killed by ADI with caspase-independent apoptosis and aggressive autophagy (or macroautophagy)(1,2,3). Autophagy is an evolutionarily-conserved process that allows cells to metabolize unwanted proteins by lysosomal breakdown during nutritional starvation(4,5). Although the essential components of this pathway are well-characterized(6,7,8,9), many aspects of the molecular mechanism are still unclear - in particular, what is the role of autophagy in the death-response of prostate cancer cells after ADI treatment? In order to address this question, we required an experimental method to measure the level and extent of autophagic response in cells - and since there are no known molecular markers that can accurately track this process, we chose to develop an imaging-based approach, using quantitative 3D fluorescence microscopy(11,12). Using CWR22Rv1 cells specifically-labeled with fluorescent probes for autophagosomes and lysosomes, we show that 3D image stacks acquired with either widefield deconvolution microscopy (and later, with super-resolution, structured-illumination microscopy) can clearly capture the early

  9. Alignment-independent technique for 3D QSAR analysis.

    PubMed

    Wilkes, Jon G; Stoyanova-Slavova, Iva B; Buzatu, Dan A

    2016-04-01

    Molecular biochemistry is controlled by 3D phenomena but structure-activity models based on 3D descriptors are infrequently used for large data sets because of the computational overhead for determining molecular conformations. A diverse dataset of 146 androgen receptor binders was used to investigate how different methods for defining molecular conformations affect the performance of 3D-quantitative spectral data activity relationship models. Molecular conformations tested: (1) global minimum of molecules' potential energy surface; (2) alignment-to-templates using equal electronic and steric force field contributions; (3) alignment using contributions "Best-for-Each" template; (4) non-energy optimized, non-aligned (2D > 3D). Aggregate predictions from models were compared. Highest average coefficients of determination ranged from R Test (2) = 0.56 to 0.61. The best model using 2D > 3D (imported directly from ChemSpider) produced R Test (2) = 0.61. It was superior to energy-minimized and conformation-aligned models and was achieved in only 3-7 % of the time required using the other conformation strategies. Predictions averaged from models built on different conformations achieved a consensus R Test (2) = 0.65. The best 2D > 3D model was analyzed for underlying structure-activity relationships. For the compound strongest binding to the androgen receptor, 10 substructural features contributing to binding were flagged. Utility of 2D > 3D was compared for two other activity endpoints, each modeling a medium sized data set. Results suggested that large scale, accurate predictions using 2D > 3D SDAR descriptors may be produced for interactions involving endocrine system nuclear receptors and other data sets in which strongest activities are produced by fairly inflexible substrates.

  10. Accuracy of 3D Imaging Software in Cephalometric Analysis

    DTIC Science & Technology

    2013-06-21

    Imaging and Communication in Medicine ( DICOM ) files into personal computer-based software to enable 3D reconstruction of the craniofacial skeleton. These...tissue profile. CBCT data can be imported as DICOM files into personal computer–based software to provide 3D reconstruction of the craniofacial...been acquired for the three pig models. The CBCT data were exported into DICOM multi-file format. They will be imported into a proprietary

  11. Alignment-independent technique for 3D QSAR analysis

    NASA Astrophysics Data System (ADS)

    Wilkes, Jon G.; Stoyanova-Slavova, Iva B.; Buzatu, Dan A.

    2016-04-01

    Molecular biochemistry is controlled by 3D phenomena but structure-activity models based on 3D descriptors are infrequently used for large data sets because of the computational overhead for determining molecular conformations. A diverse dataset of 146 androgen receptor binders was used to investigate how different methods for defining molecular conformations affect the performance of 3D-quantitative spectral data activity relationship models. Molecular conformations tested: (1) global minimum of molecules' potential energy surface; (2) alignment-to-templates using equal electronic and steric force field contributions; (3) alignment using contributions "Best-for-Each" template; (4) non-energy optimized, non-aligned (2D > 3D). Aggregate predictions from models were compared. Highest average coefficients of determination ranged from R Test 2 = 0.56 to 0.61. The best model using 2D > 3D (imported directly from ChemSpider) produced R Test 2 = 0.61. It was superior to energy-minimized and conformation-aligned models and was achieved in only 3-7 % of the time required using the other conformation strategies. Predictions averaged from models built on different conformations achieved a consensus R Test 2 = 0.65. The best 2D > 3D model was analyzed for underlying structure-activity relationships. For the compound strongest binding to the androgen receptor, 10 substructural features contributing to binding were flagged. Utility of 2D > 3D was compared for two other activity endpoints, each modeling a medium sized data set. Results suggested that large scale, accurate predictions using 2D > 3D SDAR descriptors may be produced for interactions involving endocrine system nuclear receptors and other data sets in which strongest activities are produced by fairly inflexible substrates.

  12. Crashworthiness analysis using advanced material models in DYNA3D

    SciTech Connect

    Logan, R.W.; Burger, M.J.; McMichael, L.D.; Parkinson, R.D.

    1993-10-22

    As part of an electric vehicle consortium, LLNL and Kaiser Aluminum are conducting experimental and numerical studies on crashworthy aluminum spaceframe designs. They have jointly explored the effect of heat treat on crush behavior and duplicated the experimental behavior with finite-element simulations. The major technical contributions to the state of the art in numerical simulation arise from the development and use of advanced material model descriptions for LLNL`s DYNA3D code. Constitutive model enhancements in both flow and failure have been employed for conventional materials such as low-carbon steels, and also for lighter weight materials such as aluminum and fiber composites being considered for future vehicles. The constitutive model enhancements are developed as extensions from LLNL`s work in anisotropic flow and multiaxial failure modeling. Analysis quality as a function of level of simplification of material behavior and mesh is explored, as well as the penalty in computation cost that must be paid for using more complex models and meshes. The lightweight material modeling technology is being used at the vehicle component level to explore the safety implications of small neighborhood electric vehicles manufactured almost exclusively from these materials.

  13. Parameterization of 3D brain structures for statistical shape analysis

    NASA Astrophysics Data System (ADS)

    Zhu, Litao; Jiang, Tianzi

    2004-05-01

    Statistical Shape Analysis (SSA) is a powerful tool for noninvasive studies of pathophysiology and diagnosis of brain diseases. It also provides a shape constraint for the segmentation of brain structures. There are two key problems in SSA: the representation of shapes and their alignments. The widely used parameterized representations are obtained by preserving angles or areas and the alignments of shapes are achieved by rotating parameter net. However, representations preserving angles or areas do not really guarantee the anatomical correspondence of brain structures. In this paper, we incorporate shape-based landmarks into parameterization of banana-like 3D brain structures to address this problem. Firstly, we get the triangulated surface of the object and extract two landmarks from the mesh, i.e. the ends of the banana-like object. Then the surface is parameterized by creating a continuous and bijective mapping from the surface to a spherical surface based on a heat conduction model. The correspondence of shapes is achieved by mapping the two landmarks to the north and south poles of the sphere and using an extracted origin orientation to select the dateline during parameterization. We apply our approach to the parameterization of lateral ventricle and a multi-resolution shape representation is obtained by using the Discrete Fourier Transform.

  14. Efficacy of clinical gait analysis: A systematic review.

    PubMed

    Wren, Tishya A L; Gorton, George E; Ounpuu, Sylvia; Tucker, Carole A

    2011-06-01

    The aim of this systematic review was to evaluate and summarize the current evidence base related to the clinical efficacy of gait analysis. A literature review was conducted to identify references related to human gait analysis published between January 2000 and September 2009 plus relevant older references. The references were assessed independently by four reviewers using a hierarchical model of efficacy adapted for gait analysis, and final scores were agreed upon by at least three of the four reviewers. 1528 references were identified relating to human instrumented gait analysis. Of these, 116 original articles addressed technical accuracy efficacy, 89 addressed diagnostic accuracy efficacy, 11 addressed diagnostic thinking and treatment efficacy, seven addressed patient outcomes efficacy, and one addressed societal efficacy, with some of the articles addressing multiple levels of efficacy. This body of literature provides strong evidence for the technical, diagnostic accuracy, diagnostic thinking and treatment efficacy of gait analysis. The existing evidence also indicates efficacy at the higher levels of patient outcomes and societal cost-effectiveness, but this evidence is more sparse and does not include any randomized controlled trials. Thus, the current evidence supports the clinical efficacy of gait analysis, particularly at the lower levels of efficacy, but additional research is needed to strengthen the evidence base at the higher levels of efficacy.

  15. 3-D Printed Ultem 9085 Testing and Analysis

    NASA Technical Reports Server (NTRS)

    Aguilar, Daniel; Christensen, Sean; Fox, Emmet J.

    2015-01-01

    The purpose of this document is to analyze the mechanical properties of 3-D printed Ultem 9085. This document will focus on the capabilities, limitations, and complexities of 3D printing in general, and explain the methods by which this material is tested. Because 3-D printing is a relatively new process that offers an innovative means to produce hardware, it is important that the aerospace community understands its current advantages and limitations, so that future endeavors involving 3-D printing may be completely safe. This document encompasses three main sections: a Slosh damage assessment, a destructive test of 3-D printed Ultem 9085 samples, and a test to verify simulation for the 3-D printed SDP (SPHERES Docking Port). Described below, 'Slosh' and 'SDP' refer to two experiments that are built using Ultem 9085 for use with the SPHERES (Synchronized Position Hold, Engage, Reorient, Experimental Satellites) program onboard the International Space Station (ISS) [16]. The SPHERES Facility is managed out of the National Aeronautics and Space Administration (NASA) Ames Research Center in California.

  16. 3D image analysis of abdominal aortic aneurysm

    NASA Astrophysics Data System (ADS)

    Subasic, Marko; Loncaric, Sven; Sorantin, Erich

    2001-07-01

    In this paper we propose a technique for 3-D segmentation of abdominal aortic aneurysm (AAA) from computed tomography angiography (CTA) images. Output data (3-D model) form the proposed method can be used for measurement of aortic shape and dimensions. Knowledge of aortic shape and size is very important in planning of minimally invasive procedure that is for selection of appropriate stent graft device for treatment of AAA. The technique is based on a 3-D deformable model and utilizes the level-set algorithm for implementation of the method. The method performs 3-D segmentation of CTA images and extracts a 3-D model of aortic wall. Once the 3-D model of aortic wall is available it is easy to perform all required measurements for appropriate stent graft selection. The method proposed in this paper uses the level-set algorithm for deformable models, instead of the classical snake algorithm. The main advantage of the level set algorithm is that it enables easy segmentation of complex structures, surpassing most of the drawbacks of the classical approach. We have extended the deformable model to incorporate the a priori knowledge about the shape of the AAA. This helps direct the evolution of the deformable model to correctly segment the aorta. The algorithm has been implemented in IDL and C languages. Experiments have been performed using real patient CTA images and have shown good results.

  17. Gait analysis methods for rodent models of arthritic disorders: reviews and recommendations.

    PubMed

    Lakes, E H; Allen, K D

    2016-11-01

    Gait analysis is a useful tool to understand behavioral changes in preclinical arthritis models. While observational scoring and spatiotemporal gait parameters are the most widely performed gait analyses in rodents, commercially available systems can now provide quantitative assessments of spatiotemporal patterns. However, inconsistencies remain between testing platforms, and laboratories often select different gait pattern descriptors to report in the literature. Rodent gait can also be described through kinetic and kinematic analyses, but systems to analyze rodent kinetics and kinematics are typically custom made and often require sensitive, custom equipment. While the use of rodent gait analysis rapidly expands, it is important to remember that, while rodent gait analysis is a relatively modern behavioral assay, the study of quadrupedal gait is not new. Nearly all gait parameters are correlated, and a collection of gait parameters is needed to understand a compensatory gait pattern used by the animal. As such, a change in a single gait parameter is unlikely to tell the full biomechanical story; and to effectively use gait analysis, one must consider how multiple different parameters contribute to an altered gait pattern. The goal of this article is to review rodent gait analysis techniques and provide recommendations on how to use these technologies in rodent arthritis models, including discussions on the strengths and limitations of observational scoring, spatiotemporal, kinetic, and kinematic measures. Recognizing rodent gait analysis is an evolving tool, we also provide technical recommendations we hope will improve the utility of these analyses in the future.

  18. FreeWalker: a smart insole for longitudinal gait analysis.

    PubMed

    Wang, Baitong; Rajput, Kuldeep Singh; Tam, Wing-Kin; Tung, Anthony K H; Yang, Zhi

    2015-08-01

    Gait analysis is an important diagnostic measure to investigate the pattern of walking. Traditional gait analysis is generally carried out in a gait lab, with equipped force and body tracking sensors, which needs a trained medical professional to interpret the results. This procedure is tedious, expensive, and unreliable and makes it difficult to track the progress across multiple visits. In this paper, we present a smart insole called FreeWalker, which provides quantitative gait analysis outside the confinement of traditional lab, at low- cost. The insole consists of eight pressure sensors and two motion tracking sensors, i.e. 3-axis accelerometer and 3-axis gyroscope. This enables measurement of under-foot pressure distribution and motion sequences in real-time. The insole is enabled with onboard SD card as well as wireless data transmission, which help in continuous gait-cycle analysis. The data is then sent to a gateway, for analysis and interpretation of data, using a user interface where gait features are graphically displayed. We also present validation result of a subject's left foot, who was asked to perform a specific task. Experiment results show that we could achieve a data-sampling rate of over 1 KHz, transmitting data up to a distance of 20 meter and maintain a battery life of around 24 hours. Taking advantage of these features, FreeWalker can be used in various applications, like medical diagnosis, rehabilitation, sports and entertainment.

  19. A 3D lower limb musculoskeletal model for simultaneous estimation of musculo-tendon, joint contact, ligament and bone forces during gait.

    PubMed

    Moissenet, Florent; Chèze, Laurence; Dumas, Raphaël

    2014-01-03

    Musculo-tendon forces and joint reaction forces are typically estimated using a two-step method, computing first the musculo-tendon forces by a static optimization procedure and then deducing the joint reaction forces from the force equilibrium. However, this method does not allow studying the interactions between musculo-tendon forces and joint reaction forces in establishing this equilibrium and the joint reaction forces are usually overestimated. This study introduces a new 3D lower limb musculoskeletal model based on a one-step static optimization procedure allowing simultaneous musculo-tendon, joint contact, ligament and bone forces estimation during gait. It is postulated that this approach, by giving access to the forces transmitted by these musculoskeletal structures at hip, tibiofemoral, patellofemoral and ankle joints, modeled using anatomically consistent kinematic models, should ease the validation of the model using joint contact forces measured with instrumented prostheses. A blinded validation based on four datasets was made under two different minimization conditions (i.e., C1 - only musculo-tendon forces are minimized, and C2 - musculo-tendon, joint contact, ligament and bone forces are minimized while focusing more specifically on tibiofemoral joint contacts). The results show that the model is able to estimate in most cases the correct timing of musculo-tendon forces during normal gait (i.e., the mean coefficient of active/inactive state concordance between estimated musculo-tendon force and measured EMG envelopes was C1: 65.87% and C2: 60.46%). The results also showed that the model is potentially able to well estimate joint contact, ligament and bone forces and more specifically medial (i.e., the mean RMSE between estimated joint contact force and in vivo measurement was C1: 1.14BW and C2: 0.39BW) and lateral (i.e., C1: 0.65BW and C2: 0.28BW) tibiofemoral contact forces during normal gait. However, the results remain highly influenced by the

  20. View Invariant Gait Recognition

    NASA Astrophysics Data System (ADS)

    Seely, Richard D.; Goffredo, Michela; Carter, John N.; Nixon, Mark S.

    Recognition by gait is of particular interest since it is the biometric that is available at the lowest resolution, or when other biometrics are (intentionally) obscured. Gait as a biometric has now shown increasing recognition capability. There are many approaches and these show that recognition can achieve excellent performance on current large databases. The majority of these approaches are planar 2D, largely since the early large databases featured subjects walking in a plane normal to the camera view. To extend deployment capability, we need viewpoint invariant gait biometrics. We describe approaches where viewpoint invariance is achieved by 3D approaches or in 2D. In the first group, the identification relies on parameters extracted from the 3D body deformation during walking. These methods use several video cameras and the 3D reconstruction is achieved after a camera calibration process. On the other hand, the 2D gait biometric approaches use a single camera, usually positioned perpendicular to the subject’s walking direction. Because in real surveillance scenarios a system that operates in an unconstrained environment is necessary, many of the recent gait analysis approaches are orientated toward view-invariant gait recognition.

  1. The use of laboratory gait analysis for understanding gait deterioration in people with multiple sclerosis.

    PubMed

    Cofré Lizama, L Eduardo; Khan, Fary; Lee, Peter Vs; Galea, Mary P

    2016-12-01

    Laboratory gait analysis or three-dimensional gait analysis (3DGA), which uses motion capture, force plates and electromyography (EMG), has allowed a better understanding of the underlying mechanisms of gait deterioration in patients with multiple sclerosis (PwMS). This review will summarize the current knowledge on multiple sclerosis (MS)-related changes in kinematics (angles), kinetics (forces) and electromyographic (muscle activation) patterns and how these measures can be used as markers of disease progression. We will also discuss the potential causes of slower walking in PwMS and the implications for 3DGA. Finally, we will describe new technologies and methods that will increase precision and clinical utilization of 3DGA in PwMS. Overall, 3DGA studies have shown that functionality of the ankle joint is the most affected during walking and that compensatory actions to maintain a functional speed may be insufficient in PwMS. However, altered gait patterns may be a strategy to increase stability as balance is also affected in PwMS.

  2. Computerized analysis of pelvic incidence from 3D images

    NASA Astrophysics Data System (ADS)

    Vrtovec, Tomaž; Janssen, Michiel M. A.; Pernuš, Franjo; Castelein, René M.; Viergever, Max A.

    2012-02-01

    The sagittal alignment of the pelvis can be evaluated by the angle of pelvic incidence (PI), which is constant for an arbitrary subject position and orientation and can be therefore compared among subjects in standing, sitting or supine position. In this study, PI was measured from three-dimensional (3D) computed tomography (CT) images of normal subjects that were acquired in supine position. A novel computerized method, based on image processing techniques, was developed to automatically determine the anatomical references required to measure PI, i.e. the centers of the femoral heads in 3D, and the center and inclination of the sacral endplate in 3D. Multiplanar image reformation was applied to obtain perfect sagittal views with all anatomical structures completely in line with the hip axis, from which PI was calculated. The resulting PI (mean+/-standard deviation) was equal to 46.6°+/-9.2° for male subjects (N = 189), 47.6°+/-10.7° for female subjects (N = 181), and 47.1°+/-10.0° for all subjects (N = 370). The obtained measurements of PI from 3D images were not biased by acquisition projection or structure orientation, because all anatomical structures were completely in line with the hip axis. The performed measurements in 3D therefore represent PI according to the actual geometrical relationships among anatomical structures of the sacrum, pelvis and hips, as observed from the perfect sagittal views.

  3. 3D statistical failure analysis of monolithic dental ceramic crowns.

    PubMed

    Nasrin, Sadia; Katsube, Noriko; Seghi, Robert R; Rokhlin, Stanislav I

    2016-07-05

    For adhesively retained ceramic crown of various types, it has been clinically observed that the most catastrophic failures initiate from the cement interface as a result of radial crack formation as opposed to Hertzian contact stresses originating on the occlusal surface. In this work, a 3D failure prognosis model is developed for interface initiated failures of monolithic ceramic crowns. The surface flaw distribution parameters determined by biaxial flexural tests on ceramic plates and point-to-point variations of multi-axial stress state at the intaglio surface are obtained by finite element stress analysis. They are combined on the basis of fracture mechanics based statistical failure probability model to predict failure probability of a monolithic crown subjected to single-cycle indentation load. The proposed method is verified by prior 2D axisymmetric model and experimental data. Under conditions where the crowns are completely bonded to the tooth substrate, both high flexural stress and high interfacial shear stress are shown to occur in the wall region where the crown thickness is relatively thin while high interfacial normal tensile stress distribution is observed at the margin region. Significant impact of reduced cement modulus on these stress states is shown. While the analyses are limited to single-cycle load-to-failure tests, high interfacial normal tensile stress or high interfacial shear stress may contribute to degradation of the cement bond between ceramic and dentin. In addition, the crown failure probability is shown to be controlled by high flexural stress concentrations over a small area, and the proposed method might be of some value to detect initial crown design errors.

  4. 3D image analysis of abdominal aortic aneurysm

    NASA Astrophysics Data System (ADS)

    Subasic, Marko; Loncaric, Sven; Sorantin, Erich

    2002-05-01

    This paper presents a method for 3-D segmentation of abdominal aortic aneurysm from computed tomography angiography images. The proposed method is automatic and requires minimal user assistance. Segmentation is performed in two steps. First inner and then outer aortic border is segmented. Those two steps are different due to different image conditions on two aortic borders. Outputs of these two segmentations give a complete 3-D model of abdominal aorta. Such a 3-D model is used in measurements of aneurysm area. The deformable model is implemented using the level-set algorithm due to its ability to describe complex shapes in natural manner which frequently occur in pathology. In segmentation of outer aortic boundary we introduced some knowledge based preprocessing to enhance and reconstruct low contrast aortic boundary. The method has been implemented in IDL and C languages. Experiments have been performed using real patient CTA images and have shown good results.

  5. A wireless gait analysis system by digital textile sensors.

    PubMed

    Yang, Chang-Ming; Chou, Chun-Mei; Hu, Jwu-Sheng; Hung, Shu-Hui; Yang, Chang-Hwa; Wu, Chih-Chung; Hsu, Ming-Yang; Yang, Tsi-Lin

    2009-01-01

    This paper studies the feasibility of spatio-temporal gait analysis based upon digital textile sensors. Digitized legs and feet patterns of healthy subjects and their relations with spatio-temporal gait parameters were analyzed. In the first experiment, spatio-temporal gait parameters were determined during over ground walking. In the second experiment, predicted running, backward walking, walking up stairs and walking down stairs parameters were determined. From the results of the experiments, it is concluded that, for healthy subjects, the duration of subsequent stride cycles and left/right steps, the estimations of step length, cadence, walking speed, central of pressure and central of mass trajectory, can be obtained by analyzing the digital signals from the textile sensors on pants and socks. These parameters are easily displayed in several different graphs allowing the user to view the parameters during gait. Finally, the digital data are easily to analyze the feature of activity recognition.

  6. IMU-based joint angle measurement for gait analysis.

    PubMed

    Seel, Thomas; Raisch, Jörg; Schauer, Thomas

    2014-04-16

    This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°.

  7. Reliability of 3D upper limb motion analysis in children with obstetric brachial plexus palsy.

    PubMed

    Mahon, Judy; Malone, Ailish; Kiernan, Damien; Meldrum, Dara

    2017-03-01

    Kinematics, measured by 3D upper limb motion analysis (3D-ULMA), can potentially increase understanding of movement patterns by quantifying individual joint contributions. Reliability in children with obstetric brachial plexus palsy (OBPP) has not been established.

  8. Efficiency analysis for 3D filtering of multichannel images

    NASA Astrophysics Data System (ADS)

    Kozhemiakin, Ruslan A.; Rubel, Oleksii; Abramov, Sergey K.; Lukin, Vladimir V.; Vozel, Benoit; Chehdi, Kacem

    2016-10-01

    Modern remote sensing systems basically acquire images that are multichannel (dual- or multi-polarization, multi- and hyperspectral) where noise, usually with different characteristics, is present in all components. If noise is intensive, it is desirable to remove (suppress) it before applying methods of image classification, interpreting, and information extraction. This can be done using one of two approaches - by component-wise or by vectorial (3D) filtering. The second approach has shown itself to have higher efficiency if there is essential correlation between multichannel image components as this often happens for multichannel remote sensing data of different origin. Within the class of 3D filtering techniques, there are many possibilities and variations. In this paper, we consider filtering based on discrete cosine transform (DCT) and pay attention to two aspects of processing. First, we study in detail what changes in DCT coefficient statistics take place for 3D denoising compared to component-wise processing. Second, we analyze how selection of component images united into 3D data array influences efficiency of filtering and can the observed tendencies be exploited in processing of images with rather large number of channels.

  9. Visual analysis of the effects of load carriage on gait

    NASA Astrophysics Data System (ADS)

    Wittman, Michael G.; Ward, James M.; Flynn, Patrick J.

    2005-03-01

    As early as the 1970's it was determined that gait, or the "manner of walking" is an identifying feature of a human being. Since then, extensive research has been done in the field of computer vision to determine how accurately a subject can be identified by gait characteristics. This has necessarily led to the study of how various data collection conditions, such as terrain type, varying camera angles, or a carried briefcase, may affect the identifying features of gait. However, little or no research has been done to question whether such conditions may be inferred from gait analysis. For example, is it possible to determine characteristics of the walking surface simply by looking at statistics derived from the subject's gait? The question to be addressed is whether significant concealed weight distributed on the subject's torso can be discovered through analysis of his gait. Individual trends in subjects in response to increasing concealed weight will be explored, with the objective of finding universal trends that would have obvious security purposes.

  10. Experimental 3-D SAR Human Target Signature Analysis

    DTIC Science & Technology

    2014-07-21

    through the wall structure that the radar signal must travel to get to the target, such as through and around studs . The different features from the...drywall made of wood stud , gypsum, insulating material, and vinyl coating. The second wall structure is made of cinder blocks and is a more challenging... wall synthetic aperture radar (SAR) imaging from an experimental L-band through- wall SAR prototype. Tools and algorithms for 3-D visualization are

  11. Analysis of 3-D Propagation Effects Due to Environmental Variability

    DTIC Science & Technology

    2014-09-30

    presence of 3-D environmental variations, especially shelf break canyons . Work was also performed in support of 2-D propagation in shallow water to...propagation in the Monterey Bay Canyon . This was motivated by observations of highly variable directional features in measured acoustic vector data...Rev. 8-98) Prescribed by ANSI Std Z39-18 2 the Monterey Bay Canyon were used as inputs to the model, and broadband calculations were performed

  12. 3D Display Calibration by Visual Pattern Analysis.

    PubMed

    Hwang, Hyoseok; Chang, Hyun Sung; Nam, Dongkyung; Kweon, In So

    2017-02-06

    Nearly all 3D displays need calibration for correct rendering. More often than not, the optical elements in a 3D display are misaligned from the designed parameter setting. As a result, 3D magic does not perform well as intended. The observed images tend to get distorted. In this paper, we propose a novel display calibration method to fix the situation. In our method, a pattern image is displayed on the panel and a camera takes its pictures twice at different positions. Then, based on a quantitative model, we extract all display parameters (i.e., pitch, slanted angle, gap or thickness, offset) from the observed patterns in the captured images. For high accuracy and robustness, our method analyzes the patterns mostly in frequency domain. We conduct two types of experiments for validation; one with optical simulation for quantitative results and the other with real-life displays for qualitative assessment. Experimental results demonstrate that our method is quite accurate, about a half order of magnitude higher than prior work; is efficient, spending less than 2 s for computation; and is robust to noise, working well in the SNR regime as low as 6 dB.

  13. General tensor discriminant analysis and gabor features for gait recognition.

    PubMed

    Tao, Dacheng; Li, Xuelong; Wu, Xindong; Maybank, Stephen J

    2007-10-01

    The traditional image representations are not suited to conventional classification methods, such as the linear discriminant analysis (LDA), because of the under sample problem (USP): the dimensionality of the feature space is much higher than the number of training samples. Motivated by the successes of the two dimensional LDA (2DLDA) for face recognition, we develop a general tensor discriminant analysis (GTDA) as a preprocessing step for LDA. The benefits of GTDA compared with existing preprocessing methods, e.g., principal component analysis (PCA) and 2DLDA, include 1) the USP is reduced in subsequent classification by, for example, LDA; 2) the discriminative information in the training tensors is preserved; and 3) GTDA provides stable recognition rates because the alternating projection optimization algorithm to obtain a solution of GTDA converges, while that of 2DLDA does not. We use human gait recognition to validate the proposed GTDA. The averaged gait images are utilized for gait representation. Given the popularity of Gabor function based image decompositions for image understanding and object recognition, we develop three different Gabor function based image representations: 1) the GaborD representation is the sum of Gabor filter responses over directions, 2) GaborS is the sum of Gabor filter responses over scales, and 3) GaborSD is the sum of Gabor filter responses over scales and directions. The GaborD, GaborS and GaborSD representations are applied to the problem of recognizing people from their averaged gait images.A large number of experiments were carried out to evaluate the effectiveness (recognition rate) of gait recognition based on first obtaining a Gabor, GaborD, GaborS or GaborSD image representation, then using GDTA to extract features and finally using LDA for classification. The proposed methods achieved good performance for gait recognition based on image sequences from the USF HumanID Database. Experimental comparisons are made with nine

  14. Seeing More Is Knowing More: V3D Enables Real-Time 3D Visualization and Quantitative Analysis of Large-Scale Biological Image Data Sets

    NASA Astrophysics Data System (ADS)

    Peng, Hanchuan; Long, Fuhui

    Everyone understands seeing more is knowing more. However, for large-scale 3D microscopic image analysis, it has not been an easy task to efficiently visualize, manipulate and understand high-dimensional data in 3D, 4D or 5D spaces. We developed a new 3D+ image visualization and analysis platform, V3D, to meet this need. The V3D system provides 3D visualization of gigabyte-sized microscopy image stacks in real time on current laptops and desktops. V3D streamlines the online analysis, measurement and proofreading of complicated image patterns by combining ergonomic functions for selecting a location in an image directly in 3D space and for displaying biological measurements, such as from fluorescent probes, using the overlaid surface objects. V3D runs on all major computer platforms and can be enhanced by software plug-ins to address specific biological problems. To demonstrate this extensibility, we built a V3Dbased application, V3D-Neuron, to reconstruct complex 3D neuronal structures from high-resolution brain images. V3D-Neuron can precisely digitize the morphology of a single neuron in a fruitfly brain in minutes, with about a 17-fold improvement in reliability and tenfold savings in time compared with other neuron reconstruction tools. Using V3D-Neuron, we demonstrate the feasibility of building a high-resolution 3D digital atlas of neurite tracts in the fruitfly brain. V3D can be easily extended using a simple-to-use and comprehensive plugin interface.

  15. Customisable 3D printed microfluidics for integrated analysis and optimisation.

    PubMed

    Monaghan, T; Harding, M J; Harris, R A; Friel, R J; Christie, S D R

    2016-08-16

    The formation of smart Lab-on-a-Chip (LOC) devices featuring integrated sensing optics is currently hindered by convoluted and expensive manufacturing procedures. In this work, a series of 3D-printed LOC devices were designed and manufactured via stereolithography (SL) in a matter of hours. The spectroscopic performance of a variety of optical fibre combinations were tested, and the optimum path length for performing Ultraviolet-visible (UV-vis) spectroscopy determined. The information gained in these trials was then used in a reaction optimisation for the formation of carvone semicarbazone. The production of high resolution surface channels (100-500 μm) means that these devices were capable of handling a wide range of concentrations (9 μM-38 mM), and are ideally suited to both analyte detection and process optimisation. This ability to tailor the chip design and its integrated features as a direct result of the reaction being assessed, at such a low time and cost penalty greatly increases the user's ability to optimise both their device and reaction. As a result of the information gained in this investigation, we are able to report the first instance of a 3D-printed LOC device with fully integrated, in-line monitoring capabilities via the use of embedded optical fibres capable of performing UV-vis spectroscopy directly inside micro channels.

  16. Wear Analysis of Thermal Spray Coatings on 3D Surfaces

    NASA Astrophysics Data System (ADS)

    Tillmann, W.; Luo, W.; Selvadurai, U.

    2014-01-01

    Even though the application of thermal spray coatings on complex geometries gained a greater interest in the last decade, the effect of different geometrical features on the wear behavior is still ill-defined. In this study, the wear resistance of FTC-FeCSiMn coated 3D surfaces was investigated. The wear test was carried out by means of two innovative testing procedures. The first test is a Pin-on-Tubes test where the rotating motion is realized by a lathe chuck. The specimens in the second test were fixed on the table and a robot arm operated the pin. This wear test was applied on specimens with concave or convex surfaces. The residual stresses, which were determined by means of an incremental hole-drilling method, show a dependency on the substrate geometry. The obtained stresses were put in relation to the different radii. After the wear test, a 3D-profilometer determined the wear volume and the sections of the coatings were characterized by a scanning electron microscope. The results indicate that the wear resistance is strongly influenced by the geometry of the substrate.

  17. 3D motion analysis of keratin filaments in living cells

    NASA Astrophysics Data System (ADS)

    Herberich, Gerlind; Windoffer, Reinhard; Leube, Rudolf; Aach, Til

    2010-03-01

    We present a novel and efficient approach for 3D motion estimation of keratin intermediate filaments in vitro. Keratin filaments are elastic cables forming a complex scaffolding within epithelial cells. To understand the mechanisms of filament formation and network organisation under physiological and pathological conditions, quantitative measurements of dynamic network alterations are essential. Therefore we acquired time-lapse series of 3D images using a confocal laser scanning microscope. Based on these image series, we show that a dense vector field can be computed such that the displacements from one frame to the next can be determined. Our method is based on a two-step registration process: First, a rigid pre-registration is applied in order to compensate for possible global cell movement. This step enables the subsequent nonrigid registration to capture only the sought local deformations of the filaments. As the transformation model of the deformable registration algorithm is based on Free Form Deformations, it is well suited for modeling filament network dynamics. The optimization is performed using efficient linear programming techniques such that the huge amount of image data of a time series can be efficiently processed. The evaluation of our results illustrates the potential of our approach.

  18. Metrological analysis of the human foot: 3D multisensor exploration

    NASA Astrophysics Data System (ADS)

    Muñoz Potosi, A.; Meneses Fonseca, J.; León Téllez, J.

    2011-08-01

    In the podiatry field, many of the foot dysfunctions are mainly generated due to: Congenital malformations, accidents or misuse of footwear. For the treatment or prevention of foot disorders, the podiatrist diagnoses prosthesis or specific adapted footwear, according to the real dimension of foot. Therefore, it is necessary to acquire 3D information of foot with 360 degrees of observation. As alternative solution, it was developed and implemented an optical system of threedimensional reconstruction based in the principle of laser triangulation. The system is constituted by an illumination unit that project a laser plane into the foot surface, an acquisition unit with 4 CCD cameras placed around of axial foot axis, an axial moving unit that displaces the illumination and acquisition units in the axial axis direction and a processing and exploration unit. The exploration software allows the extraction of distances on three-dimensional image, taking into account the topography of foot. The optical system was tested and their metrological performances were evaluated in experimental conditions. The optical system was developed to acquire 3D information in order to design and make more appropriate footwear.

  19. An adaptive gyroscope-based algorithm for temporal gait analysis.

    PubMed

    Greene, Barry R; McGrath, Denise; O'Neill, Ross; O'Donovan, Karol J; Burns, Adrian; Caulfield, Brian

    2010-12-01

    Body-worn kinematic sensors have been widely proposed as the optimal solution for portable, low cost, ambulatory monitoring of gait. This study aims to evaluate an adaptive gyroscope-based algorithm for automated temporal gait analysis using body-worn wireless gyroscopes. Gyroscope data from nine healthy adult subjects performing four walks at four different speeds were then compared against data acquired simultaneously using two force plates and an optical motion capture system. Data from a poliomyelitis patient, exhibiting pathological gait walking with and without the aid of a crutch, were also compared to the force plate. Results show that the mean true error between the adaptive gyroscope algorithm and force plate was -4.5 ± 14.4 ms and 43.4 ± 6.0 ms for IC and TC points, respectively, in healthy subjects. Similarly, the mean true error when data from the polio patient were compared against the force plate was -75.61 ± 27.53 ms and 99.20 ± 46.00 ms for IC and TC points, respectively. A comparison of the present algorithm against temporal gait parameters derived from an optical motion analysis system showed good agreement for nine healthy subjects at four speeds. These results show that the algorithm reported here could constitute the basis of a robust, portable, low-cost system for ambulatory monitoring of gait.

  20. Analysis of foot load during ballet dancers' gait.

    PubMed

    Prochazkova, Marketa; Tepla, Lucie; Svoboda, Zdenek; Janura, Miroslav; Cieslarová, Miloslava

    2014-01-01

    Ballet is an art that puts extreme demands on the dancer's musculoskeletal system and therefore significantly affects motor behavior of the dancers. The aim of our research was to compare plantar pressure distribution during stance phase of gait between a group of professional ballet dancers and non-dancers. Thirteen professional dancers (5 men, 8 women; mean age of 24.1 ± 3.8 years) and 13 nondancers (5 men, 8 women; mean age of 26.1 ± 5.3 years) participated in this study. Foot pressure analysis during gait was collected using a 2 m pressure plate. The participants were instructed to walk across the platform at a self-selected pace barefoot. Three gait cycles were necessary for the data analysis. The results revealed higher (p < 0.05) pressure peaks in medial edge of forefoot during gait for dancers in comparison with nondancers. Furthermore, differences in total foot loading and foot loading duration of rearfoot was higher (p < 0.05) in dancers as well. We can attribute these differences to long-term and intensive dancing exercises that can change the dancer's gait stereotype.

  1. Spatio-temporal gait analysis in children with cerebral palsy using, foot-worn inertial sensors.

    PubMed

    Brégou Bourgeois, A; Mariani, B; Aminian, K; Zambelli, P Y; Newman, C J

    2014-01-01

    A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy ± precision for both groups was 3.4 ± 4.6 cm for stride length, 4.3 ± 4.2 cm/s for speed and 0.5 ± 2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.

  2. Gait analysis of elderly women after total knee arthroplasty.

    PubMed

    Lee, Aenon; Park, Junhyuck; Lee, Seungwon

    2015-03-01

    [Purpose] The purpose of this study was to investigate ability and muscle activities of elderly women after total knee arthroplasty (TKA) and compare them with those of healthy ones. [Subjects and Methods] Fifteen female patients with TKA due to advanced degenerative arthritis of the measured on knee joint and 19 healthy elderly females participated. Tibiofemoral angles of TKA patients were using a gait analysis system anterioposterior X-rays of the weight-bearing knee. The knee flexion angle and gait parameters were measured. Muscle activities and prolongation time were EMG system. The gait of the treated limb of each participant was evaluated in three consecutive trials at fast speed and comfortable speed. [Results] The knee flexion angle %stance phase, stride length, step length, speed, cadence, and gait cycle significantly decreased at both the fast speed and comfortable speeds, and the onset and duration time of rectus femoris activity was significantly increased at the comfortable speed in the TKA group. [Conclusion] In conclusion, elderly women who received TKA showed decreased gait ability and muscle activity compared to the healthy elderly women.

  3. Gait analysis of elderly women after total knee arthroplasty

    PubMed Central

    Lee, Aenon; Park, Junhyuck; Lee, Seungwon

    2015-01-01

    [Purpose] The purpose of this study was to investigate ability and muscle activities of elderly women after total knee arthroplasty (TKA) and compare them with those of healthy ones. [Subjects and Methods] Fifteen female patients with TKA due to advanced degenerative arthritis of the measured on knee joint and 19 healthy elderly females participated. Tibiofemoral angles of TKA patients were using a gait analysis system anterioposterior X-rays of the weight-bearing knee. The knee flexion angle and gait parameters were measured. Muscle activities and prolongation time were EMG system. The gait of the treated limb of each participant was evaluated in three consecutive trials at fast speed and comfortable speed. [Results] The knee flexion angle %stance phase, stride length, step length, speed, cadence, and gait cycle significantly decreased at both the fast speed and comfortable speeds, and the onset and duration time of rectus femoris activity was significantly increased at the comfortable speed in the TKA group. [Conclusion] In conclusion, elderly women who received TKA showed decreased gait ability and muscle activity compared to the healthy elderly women. PMID:25931687

  4. When Plans Change: Task Analysis and Taxonomy of 3-D Situation Awareness Challenges of UAV Replanning

    DTIC Science & Technology

    2010-06-01

    3-D difficulties, we conducted a cognitive task analysis of the replanning problem with the Navy?s VC-6 Squadron recently returned from Iraq . Key 3-D...the Navy’s VC-6 Squadron recently returned from Iraq . Key 3-D spatial challenges involved rationalizing complex combinations of avoiding airspace and...conducted a requirements analysis of the replanning problem with Navy UAV operators recently returned from the war in Iraq , and report our findings

  5. Gait analysis and validation using voxel data.

    PubMed

    Wang, Fang; Stone, Erik; Dai, Wenqing; Skubic, Marjorie; Keller, James

    2009-01-01

    In this paper, we present a method for extracting gait parameters including walking speed, step time and step length from a three-dimensional voxel reconstruction, which is built from two calibrated camera views. These parameters are validated with a GAITRite Electronic mat and a Vicon motion capture system. Experiments were conducted in which subjects walked across the GAITRite mat at various speeds while the Vicon cameras recorded the motion of reflective markers attached to subjects' shoes, and our two calibrated cameras captured the images. Excellent agreements were found for walking speed. Step time and step length were also found to have good agreement given the limitation of frame rate and voxel resolution.

  6. Gait analysis in hip viscosupplementation for osteoarthritis: a case report.

    PubMed

    Di Lorenzo, L

    2013-10-31

    Hip is a site very commonly affected by osteoarthritis and the intra-articular administration of hyaluronic acid in the management of osteoarthritic pain is increasingly used. However, the debate about its usefulness is still ongoing, as not all results of clinical trials confirm its effectiveness. In order to achieve the best outcome, clinical assessment and treatment choices should be based on subjective outcome, pathological and mechanical findings that should be integrated with qualitative analysis of human movement. After viscosupplementation, clinical trials often evaluate as endpoint subjective outcomes (i.e. pain visual analogic scale) and static imaging such as radiographs and magnetic resonance imaging. In our clinical practice we use gait analysis as part of rehabilitation protocol to measure performance, enhancement and changes of several biomechanical factors. Taking advantage of available resources (BTS Bioengineering gait analysis Elite System) we studied a patient's gait after ultrasound guided hip injections for viscosupplementation. He showed an early clinical and biomechanical improvement during walking after a single intra articular injection of hyaluronic acid. Gait analysis parameters obtained suggest that the pre-treatment slower speed may be caused by antalgic walking patterns, the need for pain control and muscle weakness. After hip viscosupplementation, the joint displayed different temporal, kinetic and kinematic parameters associated with improved pain patterns.

  7. Validation of a Footwear-Based Gait Analysis System With Action-Related Feedback.

    PubMed

    Minto, Simone; Zanotto, Damiano; Boggs, Emily Marie; Rosati, Giulio; Agrawal, Sunil K

    2016-09-01

    Quantitative gait analysis enables clinicians to evaluate patient mobility and to diagnose neuromuscular disorders. The clinical application of gait analysis is currently limited by the high operating costs of gait laboratories. The use of instrumented footwear that performs out of the lab measurements on subjects' walking patterns is a promising way to overcome this limitation. Besides serving as assessment tools, such devices can also act as retraining tools that help regulate a patient's gait with acoustic or vibrotactile stimuli.

  8. RETRAN-3D MOD003 Peach Bottom Turbine Trip 2 Multidimensional Kinetics Analysis Models and Results

    SciTech Connect

    Mori, Michitsugu; Ogura, Katsunori; Gose, Garry C.; Wu, J.-Y

    2003-04-15

    An analysis of the Peach Bottom Unit 2 Turbine Trip Test 2 (PB2/TT2) has been performed using RETRAN-3D MOD003. The purpose of the analysis was to investigate the PB2/TT2 overpressurization transient using the RETRAN-3D multidimensional kinetics model.

  9. Gait analysis in rats with peripheral nerve injury.

    PubMed

    Yu, P; Matloub, H S; Sanger, J R; Narini, P

    2001-02-01

    Rats are commonly used to study peripheral nerve repair and grafting. The traditional footprint method to assess functional recovery is messy, indirect, and not useful when contractures develop in the animal model. The aim of the present study was to establish an accurate, reproducible, but simple, method to assess dynamic limb function. The basic quantitative aspects of a normal gait were characterized from 59 recorded walks in 23 rats. The video was digitized and analyzed frame by frame on a personal computer. Seven parameters of the gait were assessed: (1) walking speed; (2) stance phase, swing phase and right to left stance/swing ratio; (3) step length and step length ratio; (4) ankle angles at terminal stance and midswing; (5) tail height; (6) midline deviation; and (7) tail deviation. These gait parameters were then applied to groups of animals with sciatic (group S), tibial (group T), and peroneal (group P) nerve injuries. A discriminant analysis was performed to analyze each parameter and to compute a functional score. We found that the video gait analysis was superior to the footprint method and believe it will be very useful in future studies on peripheral nerve injury.

  10. Therapeutic electrical stimulation for spasticity: quantitative gait analysis.

    PubMed

    Pease, W S

    1998-01-01

    Improvement in motor function following electrical stimulation is related to strengthening of the stimulated spastic muscle and inhibition of the antagonist. A 26-year-old man with familial spastic paraparesis presented with gait dysfunction and bilateral lower limb spastic muscle tone. Clinically, muscle strength and sensation were normal. He was considered appropriate for a trial of therapeutic electrical stimulation following failed trials of physical therapy and baclofen. No other treatment was used concurrent with the electrical stimulation. Before treatment, quantitative gait analysis revealed 63% of normal velocity and a crouched gait pattern, associated with excessive electromyographic activity in the hamstrings and gastrocnemius muscles. Based on these findings, bilateral stimulation of the quadriceps and anterior compartment musculature was performed two to three times per week for three months. Repeat gait analysis was conducted three weeks after the cessation of stimulation treatment. A 27% increase in velocity was noted associated with an increase in both cadence and right step length. Right hip and bilateral knee stance motion returned to normal (rather than "crouched"). No change in the timing of dynamic electromyographic activity was seen. These findings suggest a role for the use of electrical stimulation for rehabilitation of spasticity. The specific mechanism of this improvement remains uncertain.

  11. Vibration Analysis using 3D Image Correlation Technique

    NASA Astrophysics Data System (ADS)

    Siebert, T.; Splitthof, K.

    2010-06-01

    Digital speckle correlation techniques have already been successfully proven to be an accurate displacement analysis tool for a wide range of applications. With the use of two cameras, three dimensional measurements of contours and displacements can be carried out. With a simple setup it opens a wide range of applications. Rapid new developments in the field of digital imaging and computer technology opens further applications for these measurement methods to high speed deformation and strain analysis, e.g. in the fields of material testing, fracture mechanics, advanced materials and component testing. The high resolution of the deformation measurements in space and time opens a wide range of applications for vibration analysis of objects. Since the system determines the absolute position and displacements of the object in space, it is capable of measuring high amplitudes and even objects with rigid body movements. The absolute resolution depends on the field of view and is scalable. Calibration of the optical setup is a crucial point which will be discussed in detail. Examples of the analysis of harmonic vibration and transient events from material research and industrial applications are presented. The results show typical features of the system.

  12. Reducing Non-Uniqueness in Satellite Gravity Inversion using 3D Object Oriented Image Analysis Techniques

    NASA Astrophysics Data System (ADS)

    Fadel, I.; van der Meijde, M.; Kerle, N.

    2013-12-01

    Non-uniqueness of satellite gravity interpretation has been usually reduced by using a priori information from various sources, e.g. seismic tomography models. The reduction in non-uniqueness has been based on velocity-density conversion formulas or user interpretation for 3D subsurface structures (objects) in seismic tomography models. However, these processes introduce additional uncertainty through the conversion relations due to the dependency on the other physical parameters such as temperature and pressure, or through the bias in the interpretation due to user choices and experience. In this research, a new methodology is introduced to extract the 3D subsurface structures from 3D geophysical data using a state-of-art 3D Object Oriented Image Analysis (OOA) technique. 3D OOA is tested using a set of synthetic models that simulate the real situation in the study area of this research. Then, 3D OOA is used to extract 3D subsurface objects from a real 3D seismic tomography model. The extracted 3D objects are used to reconstruct a forward model and its response is compared with the measured satellite gravity. Finally, the result of the forward modelling, based on the extracted 3D objects, is used to constrain the inversion process of satellite gravity data. Through this work, a new object-based approach is introduced to interpret and extract the 3D subsurface objects from 3D geophysical data. This can be used to constrain modelling and inversion of potential field data using the extracted 3D subsurface structures from other methods. In summary, a new approach is introduced to constrain inversion of satellite gravity measurements and enhance interpretation capabilities.

  13. An optical real-time 3D measurement for analysis of facial shape and movement

    NASA Astrophysics Data System (ADS)

    Zhang, Qican; Su, Xianyu; Chen, Wenjing; Cao, Yiping; Xiang, Liqun

    2003-12-01

    Optical non-contact 3-D shape measurement provides a novel and useful tool for analysis of facial shape and movement in presurgical and postsurgical regular check. In this article we present a system, which allows a precise 3-D visualization of the patient's facial before and after craniofacial surgery. We discussed, in this paper, the real time 3-D image capture, processing and the 3-D phase unwrapping method to recover complex shape deformation when the movement of the mouth. The result of real-time measurement for facial shape and movement will be helpful for the more ideal effect in plastic surgery.

  14. On 3-D inelastic analysis methods for hot section components

    NASA Technical Reports Server (NTRS)

    Todd, E. S.

    1986-01-01

    The objective of this program is to produce a series of new computer codes that permit more accurate and efficient three-dimensional inelastic structural analysis of combustor liners, turbine blades, and turbine vanes. Each code embodies a progression of mathematical models for increasingly comprehensive representation of the geometrical features, loading conditions, and forms of nonlinear material response that distinguish these three groups of hot section components.

  15. 3D neutronic/thermal-hydraulic coupled analysis of MYRRHA

    SciTech Connect

    Vazquez, M.; Martin-Fuertes, F.

    2012-07-01

    The current tendency in multiphysics calculations applied to reactor physics is the use of already validated computer codes, coupled by means of an iterative approach. In this paper such an approach is explained concerning neutronics and thermal-hydraulics coupled analysis with MCNPX and COBRA-IV codes using a driver program and file exchange between codes. MCNPX provides the neutronic analysis of heterogeneous nuclear systems, both in critical and subcritical states, while COBRA-IV is a subchannel code that can be used for rod bundles or core thermal-hydraulics analysis. In our model, the MCNP temperature dependence of nuclear data is handled via pseudo-material approach, mixing pre-generated cross section data set to obtain the material with the desired cross section temperature. On the other hand, COBRA-IV has been updated to allow for the simulation of liquid metal cooled reactors. The coupled computational tool can be applied to any geometry and coolant, as it is the case of single fuel assembly, at pin-by-pin level, or full core simulation with the average pin of each fuel-assembly. The coupling tool has been applied to the critical core layout of the SCK-CEN MYRRHA concept, an experimental LBE cooled fast reactor presently in engineering design stage. (authors)

  16. Vector algorithms for geometrically nonlinear 3D finite element analysis

    NASA Technical Reports Server (NTRS)

    Whitcomb, John D.

    1989-01-01

    Algorithms for geometrically nonlinear finite element analysis are presented which exploit the vector processing capability of the VPS-32, which is closely related to the CYBER 205. By manipulating vectors (which are long lists of numbers) rather than individual numbers, very high processing speeds are obtained. Long vector lengths are obtained without extensive replication or reordering by storage of intermediate results in strategic patterns at all stages of the computations. Comparisons of execution times with those from programs using either scalar or other vector programming techniques indicate that the algorithms presented are quite efficient.

  17. 3D inelastic analysis methods for hot section components

    NASA Technical Reports Server (NTRS)

    Dame, L. T.; Chen, P. C.; Hartle, M. S.; Huang, H. T.

    1985-01-01

    The objective is to develop analytical tools capable of economically evaluating the cyclic time dependent plasticity which occurs in hot section engine components in areas of strain concentration resulting from the combination of both mechanical and thermal stresses. Three models were developed. A simple model performs time dependent inelastic analysis using the power law creep equation. The second model is the classical model of Professors Walter Haisler and David Allen of Texas A and M University. The third model is the unified model of Bodner, Partom, et al. All models were customized for linear variation of loads and temperatures with all material properties and constitutive models being temperature dependent.

  18. High Resolution Krylov Space 3-D Wavenumber-Frequency Analysis

    DTIC Science & Technology

    2007-04-01

    wavenumber-frequency distri- bution of signal modes. That is, PPER (k, f, t) = eH(k) R̂[f, t] e(k). (3) Different from eq.(2), here R̂[f, t] is a time... PPER (k, f, t) frequency f w av en um be r k Capon wavenumber frequency analysis 0.4 0.5 0.6 0.7 0.8 0.9 1 0.5 0.4 0.3 0.2 0.1 0 0.1 0.2 0.3 0.4 0.5 30

  19. Modeling and analysis of 3-D elongated shapes with applications to long bone morphometry

    SciTech Connect

    Burdin, V.; Roux, C.; Lefevre, C.; Stindel, E.

    1996-02-01

    This paper presents a geometric model to be used as a framework for the description and analysis of three-dimensional (3-D) elongated shapes. Elongated shapes can be decomposed into two different parts: a 3-D curve (the central axis) and a 3-D surface (the straight surface). The central axis is described in terms of curvature and torsion. A novel concept of torsion image is introduced which allows the user to study the torsion of some relevant 3-D structures such as the medulla of long bones, without computing the third derivative. The description of the straight surface is based on an ordered set of Fourier Descriptors (FD`s), each set representing a 2-D slice of the structure. These descriptors possess completeness, continuity, and stability properties, and some geometrical invariancies. A polar diagram is built which contains the anatomical information of the straight surface and can be used as a tool for the analysis and discrimination of 3-D structures. A technique for the reconstruction of the 3-D surface from the model`s two components is presented. Various applications to the analysis of long bone structures, such as the ulna and radius, are derived from the model, namely, data compression, comparison of 3-D shapes, segmentation into 3-D primitives, and torsion and curvature analysis. The relevance of the method to morphometry and to clinical applications is discussed.

  20. Gait Analysis and the Cumulative Gait Index (CGI): Translational Tools to Assess Impairments Exhibited by Rats with Olivocerebellar Ataxia

    PubMed Central

    Lambert, C.S.; Philpot, R.M.; Engberg, M.E.; Johns, B.E.; Kim, S.H.; Wecker, L.

    2014-01-01

    Deviations from ‘normal’ locomotion exhibited by humans and laboratory animals may be determined using automated systems that capture both temporal and spatial gait parameters. Although many measures generated by these systems are unrelated and independent, some may be related and dependent, representing redundant assessments of function. To investigate this possibility, a treadmill-based system was used to capture gait parameters from normal and ataxic rats, and a multivariate analysis was conducted to determine deviations from normal. Rats were trained on the treadmill at two speeds, and gait parameters were generated prior to and following lesions of the olivocerebellar pathway. Control (non-lesioned) animals exhibited stable hindlimb gait parameters across assessments at each speed. Lesioned animals exhibited alterations in multiple hindlimb gait parameters, characterized by significant increases in stride frequency, braking duration, stance width, step angle, and paw angle and decreases in stride, stance, swing and propulsion durations, stride length and paw area. A principal component analysis of initial hindlimb measures indicated 3 uncorrelated factors mediating performance, termed rhythmicity, thrust and contact. Deviation in the performance of each animal from the group mean was determined for each factor and values summed to yield the Cumulative Gait Index (CGI), a single value reflecting variation within the group. The CGI for lesioned animals increased 2.3-fold relative to unlesioned animals. This study characterizes gait alterations in laboratory rats rendered ataxic by destruction of the climbing fiber pathway innervating Purkinje cells and demonstrates that a single index can be used to describe overall gait impairments. PMID:25116252

  1. Gait variability in people with neurological disorders: A systematic review and meta-analysis.

    PubMed

    Moon, Yaejin; Sung, JongHun; An, Ruopeng; Hernandez, Manuel E; Sosnoff, Jacob J

    2016-06-01

    There has been growing evidence showing gait variability provides unique information about gait characteristics in neurological disorders. This study systemically reviewed and quantitatively synthesized (via meta-analysis) existing evidence on gait variability in various neurological diseases, including Alzheimer's disease (AD), amyotrophic lateral sclerosis (ALS), cerebellar ataxia (CA), Huntington's disease (HD), multiple sclerosis (MS), and Parkinson's disease (PD). Keyword search were conducted in PubMed, Web of science, Cumulative Index to Nursing and Allied Health Literature, and Cochrane Library. Meta-analysis was performed to estimate the pooled effect size for gait variability for each neurological group. Meta-regression was performed to compare gait variability across multiple groups with neurological diseases. Gait variability of 777 patients with AD, ALS, CA, HD, MS, or PD participating in 25 studies was included in meta-analysis. All pathological groups had increased amount of gait variability and loss of fractal structure of gait dynamics compared to healthy controls, and gait variability differentiated distinctive neurological conditions. The HD groups had the highest alterations in gait variability among all pathological groups, whereas the PD, AD and MS groups had the lowest. Interventions that aim to improve gait function in patients with neurological disorders should consider the heterogeneous relationship between gait variability and neurological conditions.

  2. Evaluation of stereoscopic 3D displays for image analysis tasks

    NASA Astrophysics Data System (ADS)

    Peinsipp-Byma, E.; Rehfeld, N.; Eck, R.

    2009-02-01

    In many application domains the analysis of aerial or satellite images plays an important role. The use of stereoscopic display technologies can enhance the image analyst's ability to detect or to identify certain objects of interest, which results in a higher performance. Changing image acquisition from analog to digital techniques entailed the change of stereoscopic visualisation techniques. Recently different kinds of digital stereoscopic display techniques with affordable prices have appeared on the market. At Fraunhofer IITB usability tests were carried out to find out (1) with which kind of these commercially available stereoscopic display techniques image analysts achieve the best performance and (2) which of these techniques achieve a high acceptance. First, image analysts were interviewed to define typical image analysis tasks which were expected to be solved with a higher performance using stereoscopic display techniques. Next, observer experiments were carried out whereby image analysts had to solve defined tasks with different visualization techniques. Based on the experimental results (performance parameters and qualitative subjective evaluations of the used display techniques) two of the examined stereoscopic display technologies were found to be very good and appropriate.

  3. A force measuring treadmill in clinical gait analysis.

    PubMed

    Dierick, Frédéric; Penta, Massimo; Renaut, David; Detrembleur, Christine

    2004-12-01

    This preliminary study presents the development and testing of an instrumented treadmill device measuring the ground reaction forces (GRFs) and the feasibility of using this force measuring treadmill (FMT) in clinical gait analysis. A commercially available treadmill was modified and fitted out with three-dimensional strain-gauge force transducers. Tests of linearity, centre of pressure position (CoP), cross talk, natural frequency, background noises, and belt speed were undertaken in order to assess the performance of the FMT. In addition, the GRFs and segmental kinematics were recorded while healthy subjects and patients walked on the FMT, in order to compute the net ankle joint moments and the body centre of mass (CMb) kinematics and mechanics. The preliminary results of technical tests were satisfactory with an error less than 10% and dynamic tests in healthy subjects corresponded to the literature. The results of patients were clearly disturbed, demonstrating the ability of the FMT to discriminate pathological gaits from normal ones. We concluded that the GRFs measurements obtained from the FMT seem valid and the clinical assessment of net joint moments and CMb kinematics and mechanics seem feasible. The FMT could be useful device for clinical research and routine gait analysis since it allows gaining some extra room and quickly collecting the GRFs during a large number of successive gait cycles and over a wide range of steady-state gait speeds. However, more work is needed in this area in order to confirm the present results, collect reference data and validate the methodology across pathologies.

  4. Gait analysis in a mouse model resembling Leigh disease.

    PubMed

    de Haas, Ria; Russel, Frans G; Smeitink, Jan A

    2016-01-01

    Leigh disease (LD) is one of the clinical phenotypes of mitochondrial OXPHOS disorders and also known as sub-acute necrotizing encephalomyelopathy. The disease has an incidence of 1 in 77,000 live births. Symptoms typically begin early in life and prognosis for LD patients is poor. Currently, no clinically effective treatments are available. Suitable animal and cellular models are necessary for the understanding of the neuropathology and the development of successful new therapeutic strategies. In this study we used the Ndufs4 knockout (Ndufs4(-/-)) mouse, a model of mitochondrial complex I deficiency. Ndusf4(-/-) mice exhibit progressive neurodegeneration, which closely resemble the human LD phenotype. When dissecting behavioral abnormalities in animal models it is of great importance to apply translational tools that are clinically relevant. To distinguish gait abnormalities in patients, simple walking tests can be assessed, but in animals this is not easy. This study is the first to demonstrate automated CatWalk gait analysis in the Ndufs4(-/-) mouse model. Marked differences were noted between Ndufs4(-/-) and control mice in dynamic, static, coordination and support parameters. Variation of walking speed was significantly increased in Ndufs4(-/-) mice, suggesting hampered and uncoordinated gait. Furthermore, decreased regularity index, increased base of support and changes in support were noted in the Ndufs4(-/-) mice. Here, we report the ability of the CatWalk system to sensitively assess gait abnormalities in Ndufs4(-/-) mice. This objective gait analysis can be of great value for intervention and drug efficacy studies in animal models for mitochondrial disease.

  5. Sub aquatic 3D visualization and temporal analysis utilizing ArcGIS online and 3D applications

    EPA Science Inventory

    We used 3D Visualization tools to illustrate some complex water quality data we’ve been collecting in the Great Lakes. These data include continuous tow data collected from our research vessel the Lake Explorer II, and continuous water quality data collected from an autono...

  6. 3D site specific sample preparation and analysis of 3D devices (FinFETs) by atom probe tomography.

    PubMed

    Kambham, Ajay Kumar; Kumar, Arul; Gilbert, Matthieu; Vandervorst, Wilfried

    2013-09-01

    With the transition from planar to three-dimensional device architectures such as Fin field-effect-transistors (FinFETs), new metrology approaches are required to meet the needs of semiconductor technology. It is important to characterize the 3D-dopant distributions precisely as their extent, positioning relative to gate edges and absolute concentration determine the device performance in great detail. At present the atom probe has shown its ability to analyze dopant distributions in semiconductor and thin insulating materials with sub-nm 3D-resolution and good dopant sensitivity. However, so far most reports have dealt with planar devices or restricted the measurements to 2D test structures which represent only limited challenges in terms of localization and site specific sample preparation. In this paper we will discuss the methodology to extract the dopant distribution from real 3D-devices such as a 3D-FinFET device, requiring the sample preparation to be carried out at a site specific location with a positioning accuracy ∼50 nm.

  7. 3D Reacting Flow Analysis of LANTR Nozzles

    NASA Astrophysics Data System (ADS)

    Stewart, Mark E. M.; Krivanek, Thomas M.; Hemminger, Joseph A.; Bulman, M. J.

    2006-01-01

    This paper presents performance predictions for LANTR nozzles and the system implications for their use in a manned Mars mission. The LANTR concept is rocket thrust augmentation by injecting Oxygen into the nozzle to combust the Hydrogen exhaust of a Nuclear Thermal Rocket. The performance predictions are based on three-dimensional reacting flow simulations using VULCAN. These simulations explore a range of O2/H2 mixture ratios, injector configurations, and concepts. These performance predictions are used for a trade analysis within a system study for a manned Mars mission. Results indicate that the greatest benefit of LANTR will occur with In-Situ Resource Utilization (ISRU). However, Hydrogen propellant volume reductions may allow greater margins for fitting tanks within the launch vehicle where packaging issues occur.

  8. Galerkin Boundary Integral Analysis for the 3D Helmholtz Equation

    SciTech Connect

    Swager, Melissa; Gray, Leonard J; Nintcheu Fata, Sylvain

    2010-01-01

    A linear element Galerkin boundary integral analysis for the three-dimensional Helmholtz equation is presented. The emphasis is on solving acoustic scattering by an open (crack) surface, and to this end both a dual equation formulation and a symmetric hypersingular formulation have been developed. All singular integrals are defined and evaluated via a boundary limit process, facilitating the evaluation of the (finite) hypersingular Galerkin integral. This limit process is also the basis for the algorithm for post-processing of the surface gradient. The analytic integrations required by the limit process are carried out by employing a Taylor series expansion for the exponential factor in the Helmholtz fundamental solutions. For the open surface, the implementations are validated by comparing the numerical results obtained by using the two different methods.

  9. Code System for Analysis of 3-D Reinforced Concrete Structures.

    SciTech Connect

    ANDERSON, C. A.

    1999-11-22

    Version 00 NONSAP-C is a finite element program for determining the static and dynamic response of three-dimensional reinforced concrete structures. Long-term, or creep, behavior of concrete structures can also be analyzed. Nonlinear constitutive relations for concrete under short-term loads are incorporated in two time-independent models, a variable-modulus approach with orthotropic behavior induced in the concrete due to the development of different tangent moduli in different directions and an elastic-plastic model in which the concrete is assumed to be a continuous, isotropic, and linearly elastic-plastic strain-hardening-fracture material. A viscoelastic constitutive model for long-term thermal creep of concrete is included. Three-dimensional finite elements available in NONSAP-C include a truss element, a multinode tendon element for prestressed and post tensioned concrete structures, an elastic-plastic membrane element to represent the behavior of cavity liners, and a general isoparametric element with a variable number of nodes for analysis of solids and thick shells.

  10. Gait Speed Predicts Incident Disability: A Pooled Analysis

    PubMed Central

    Patel, Kushang V.; Rosano, Caterina; Rubin, Susan M.; Satterfield, Suzanne; Harris, Tamara; Ensrud, Kristine; Orwoll, Eric; Lee, Christine G.; Chandler, Julie M.; Newman, Anne B.; Cauley, Jane A.; Guralnik, Jack M.; Ferrucci, Luigi; Studenski, Stephanie A.

    2016-01-01

    Background. Functional independence with aging is an important goal for individuals and society. Simple prognostic indicators can inform health promotion and care planning, but evidence is limited by heterogeneity in measures of function. Methods. We performed a pooled analysis of data from seven studies of 27,220 community-dwelling older adults aged 65 or older with baseline gait speed, followed for disability and mortality. Outcomes were incident inability or dependence on another person in bathing or dressing; and difficulty walking ¼ – ½ mile or climbing 10 steps within 3 years. Results. Participants with faster baseline gait had lower rates of incident disability. In subgroups (defined by 0.2 m/s-wide intervals from <0.4 to ≥1.4 m/s) with increasingly greater gait speed, 3-year rates of bathing or dressing dependence trended from 10% to 1% in men, and from 15% to 1% in women, while mobility difficulty trended from 47% to 4% in men and 40% to 6% in women. The age-adjusted relative risk ratio per 0.1 m/s greater speed for bathing or dressing dependence in men was 0.68 (0.57–0.81) and in women: 0.74 (0.66–0.82); for mobility difficulty, men: 0.75 (0.68–0.82), women: 0.73 (0.67–0.80). Results were similar for combined disability and mortality. Effects were largely consistent across subgroups based on age, gender, race, body mass index, prior hospitalization, and selected chronic conditions. In the presence of multiple other risk factors for disability, gait speed significantly increased the area under the receiver operator characteristic curve. Conclusion. In older adults, gait speed predicts 3 year incidence of bathing or dressing dependence, mobility difficulty, and a composite outcome of disability and mortality. PMID:26297942

  11. IMPROMPTU: a system for automatic 3D medical image-analysis.

    PubMed

    Sundaramoorthy, G; Hoford, J D; Hoffman, E A; Higgins, W E

    1995-01-01

    The utility of three-dimensional (3D) medical imaging is hampered by difficulties in extracting anatomical regions and making measurements in 3D images. Presently, a user is generally forced to use time-consuming, subjective, manual methods, such as slice tracing and region painting, to define regions of interest. Automatic image-analysis methods can ameliorate the difficulties of manual methods. This paper describes a graphical user interface (GUI) system for constructing automatic image-analysis processes for 3D medical-imaging applications. The system, referred to as IMPROMPTU, provides a user-friendly environment for prototyping, testing and executing complex image-analysis processes. IMPROMPTU can stand alone or it can interact with an existing graphics-based 3D medical image-analysis package (VIDA), giving a strong environment for 3D image-analysis, consisting of tools for visualization, manual interaction, and automatic processing. IMPROMPTU links to a large library of 1D, 2D, and 3D image-processing functions, referred to as VIPLIB, but a user can easily link in custom-made functions. 3D applications of the system are given for left-ventricular chamber, myocardial, and upper-airway extractions.

  12. Advanced Visualization and Analysis of Climate Data using DV3D and UV-CDAT

    NASA Astrophysics Data System (ADS)

    Maxwell, T. P.

    2012-12-01

    This paper describes DV3D, a Vistrails package of high-level modules for the Ultra-scale Visualization Climate Data Analysis Tools (UV-CDAT) interactive visual exploration system that enables exploratory analysis of diverse and rich data sets stored in the Earth System Grid Federation (ESGF). DV3D provides user-friendly workflow interfaces for advanced visualization and analysis of climate data at a level appropriate for scientists. The application builds on VTK, an open-source, object-oriented library, for visualization and analysis. DV3D provides the high-level interfaces, tools, and application integrations required to make the analysis and visualization power of VTK readily accessible to users without exposing burdensome details such as actors, cameras, renderers, and transfer functions. It can run as a desktop application or distributed over a set of nodes for hyperwall or distributed visualization applications. DV3D is structured as a set of modules which can be linked to create workflows in Vistrails. Figure 1 displays a typical DV3D workflow as it would appear in the Vistrails workflow builder interface of UV-CDAT and, on the right, the visualization spreadsheet output of the workflow. Each DV3D module encapsulates a complex VTK pipeline with numerous supporting objects. Each visualization module implements a unique interactive 3D display. The integrated Vistrails visualization spreadsheet offers multiple synchronized visualization displays for desktop or hyperwall. The currently available displays include volume renderers, volume slicers, 3D isosurfaces, 3D hovmoller, and various vector plots. The DV3D GUI offers a rich selection of interactive query, browse, navigate, and configure options for all displays. All configuration operations are saved as Vistrails provenance. DV3D's seamless integration with UV-CDAT's climate data management system (CDMS) and other climate data analysis tools provides a wide range of climate data analysis operations, e

  13. 3D Building Models Segmentation Based on K-Means++ Cluster Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Mao, B.

    2016-10-01

    3D mesh model segmentation is drawing increasing attentions from digital geometry processing field in recent years. The original 3D mesh model need to be divided into separate meaningful parts or surface patches based on certain standards to support reconstruction, compressing, texture mapping, model retrieval and etc. Therefore, segmentation is a key problem for 3D mesh model segmentation. In this paper, we propose a method to segment Collada (a type of mesh model) 3D building models into meaningful parts using cluster analysis. Common clustering methods segment 3D mesh models by K-means, whose performance heavily depends on randomized initial seed points (i.e., centroid) and different randomized centroid can get quite different results. Therefore, we improved the existing method and used K-means++ clustering algorithm to solve this problem. Our experiments show that K-means++ improves both the speed and the accuracy of K-means, and achieve good and meaningful results.

  14. User's Manual for DuctE3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic Analysis of Ducted Fans

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1997-01-01

    The program DuctE3D is used for steady or unsteady aerodynamic and aeroelastic analysis of ducted fans. This guide describes the input data required and the output files generated, in using DuctE3D. The analysis solves three dimensional unsteady, compressible Euler equations to obtain the aerodynamic forces. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either the time domain or the frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis and aeroelastic analysis of an isolated fan row.

  15. Multifractal detrended fluctuation analysis of human gait diseases

    PubMed Central

    Dutta, Srimonti; Ghosh, Dipak; Chatterjee, Sucharita

    2013-01-01

    In this paper multifractal detrended fluctuation analysis (MFDFA) is used to study the human gait time series for normal and diseased sets. It is observed that long range correlation is primarily responsible for the origin of multifractality. The study reveals that the degree of multifractality is more for normal set compared to diseased set. However, the method fails to distinguish between the two diseased sets. PMID:24109454

  16. Gait analysis to guide a selective dorsal rhizotomy program.

    PubMed

    Roberts, Andrew; Stewart, Caroline; Freeman, Robert

    2015-06-01

    Selective dorsal rhizotomy is a valuable surgical option to manage spasticity in children with bilateral cerebral palsy with the objective of improving function. Choosing the correct patient for rhizotomy requires considerable effort and a comprehensive evaluation. Instrumented three-dimensional gait analysis provides supporting evidence in the selection of the ideal child for SDR as well as enabling quantitative monitoring of outcome and post-operative management up to skeletal maturity.

  17. First metatarsophalangeal arthrodesis: a clinical, pedobarographic and gait analysis study.

    PubMed

    DeFrino, Paul Francis; Brodsky, James White; Pollo, Fabian E; Crenshaw, Stephanie J; Beischer, Andrew D

    2002-06-01

    This study investigated the results of first metatarsophalangeal (MTP) arthrodesis in terms of clinical outcome measures, plantar pressure distribution, and gait patterns. Ten feet in nine patients with severe hallux rigidus (HR) who underwent first MTP arthrodesis were studied. The preoperative evaluation included a subjective questionnaire, physical exam, AOFAS hallux score, radiographs and dynamic pedobarography (EMED). At follow-up (average 34 months) these were repeated, and gait analysis studies were obtained. Patients showed significant clinical improvement based on the subjective criteria. The mean AOFAS score improved from 38 preoperatively to 90 postoperatively. Postoperative EMED analysis showed restoration of the weightbearing function of the first ray, with greater maximum force carried by the distal hallux at toe-off. Kinematic and kinetic gait analysis from each patient's operative limb were compared to the unaffected contralateral limb and to age- and sex-matched healthy subjects. The kinematic data indicated a significantly shorter step length with some loss in ankle plantar flexion at toe-off on the fused side. The kinetic data indicated a reduction in both ankle torque and ankle power at push-off. Clinical results indicated effective pain relief and a high level of patient satisfaction, consistent with previous reports in patients with symptomatic Hallux Rigidus.

  18. Spinal alignment evolution with age: A prospective gait analysis study

    PubMed Central

    Pesenti, Sébastien; Blondel, Benjamin; Peltier, Emilie; Viehweger, Elke; Pomero, Vincent; Authier, Guillaume; Fuentes, Stéphane; Jouve, Jean-Luc

    2017-01-01

    AIM To describe, using gait analysis, the development of spinal motion in the growing child. METHODS Thirty-six healthy children aged from 3 to 16 years old were included in this study for a gait analysis (9 m-walk). Various kinematic parameters were recorded and analyzed such as thoracic angle (TA), lumbar angle (LA) and sagittal vertical axis (SVA). The kinetic parameters were the net reaction moments (N.m/kg) at the thoracolumbar and lumbosacral junctions. RESULTS TA and LA curves were not statistically correlated to the age (respectively, P = 0.32 and P = 0.41). SVA increased significantly with age (P < 0.001). Moments in sagittal plane at the lumbosacral junction were statistically correlated to the age (P = 0.003), underlining the fact that sagittal mechanical constraints at the lumbosacral junction increase with age. Moments in transversal plane at the thoracolumbar and lumbosacral junctions were statistically correlated to the age (P = 0.0002 and P = 0.0006), revealing that transversal mechanical constraints decrease with age. CONCLUSION The kinetic analysis showed that during growth, a decrease of torsional constraint occurs while an increase of sagittal constraint is observed. These changes in spine biomechanics are related to the crucial role of the trunk for bipedalism acquisition, allowing stabilization despite lower limbs immaturity. With the acquisition of mature gait, the spine will mainly undergo constraints in the sagittal plane. PMID:28361018

  19. The 3D Tele Motion Tracking for the Orthodontic Facial Analysis

    PubMed Central

    Nota, Alessandro; Marchetti, Enrico; Padricelli, Giuseppe; Marzo, Giuseppe

    2016-01-01

    Aim. This study aimed to evaluate the reliability of 3D-TMT, previously used only for dynamic testing, in a static cephalometric evaluation. Material and Method. A group of 40 patients (20 males and 20 females; mean age 14.2 ± 1.2 years; 12–18 years old) was included in the study. The measurements obtained by the 3D-TMT cephalometric analysis with a conventional frontal cephalometric analysis were compared for each subject. Nine passive markers reflectors were positioned on the face skin for the detection of the profile of the patient. Through the acquisition of these points, corresponding plans for three-dimensional posterior-anterior cephalometric analysis were found. Results. The cephalometric results carried out with 3D-TMT and with traditional posterior-anterior cephalometric analysis showed the 3D-TMT system values are slightly higher than the values measured on radiographs but statistically significant; nevertheless their correlation is very high. Conclusion. The recorded values obtained using the 3D-TMT analysis were correlated to cephalometric analysis, with small but statistically significant differences. The Dahlberg errors resulted to be always lower than the mean difference between the 2D and 3D measurements. A clinician should use, during the clinical monitoring of a patient, always the same method, to avoid comparing different millimeter magnitudes. PMID:28044130

  20. The relationship between clinical measurements and gait analysis data in children with cerebral palsy.

    PubMed

    Domagalska, Małgorzata; Szopa, Andrzej; Syczewska, Małgorzata; Pietraszek, Stanisław; Kidoń, Zenon; Onik, Grzegorz

    2013-09-01

    Spasticity is a common impairment that interferes with motor function (particularly gait pattern) in children with cerebral palsy (CP). Gait analysis and clinical measurements are equally important in evaluating and treating gait disorders in children with CP. This study aimed to explore the relationship between the spasticity of lower extremity muscles and deviations from the normal gait pattern in children with CP. Thirty-six children with spastic CP (18 with spastic hemiplegia [HS] and 18 with spastic diplegia [DS]), ranging in age from 7 to 12 years, participated in the study. The children were classified as level I (n=24) or level II (n=12) according to the Gross Motor Function Classification System. Spasticity levels were evaluated with the Dynamic Evaluation of Range of Motion (DAROM) using the accelerometer-based system, and gait patterns were evaluated with a three dimensional gait analysis using the Zebris system (Isny, Germany). The Gillette Gait Index (GGI) was calculated from the gait data. The results show that gait pathology in children with CP does not depend on the static and dynamic contractures of hip and knee flexors. Although significant correlations were observed for a few clinical measures with the gait data (GGI), the correlation coefficients were low. Only the spasticity of rectus femoris showed a fair to moderate correlation with GGI. In conclusion, the results indicate the independence of the clinical evaluation and gait pattern and support the view that both factors provide important information about the functional problems of children with CP.

  1. 3D shape analysis for early diagnosis of malignant lung nodules.

    PubMed

    El-Baz, Ayman; Nitzken, Matthew; Elnakib, Ahmed; Khalifa, Fahmi; Gimel'farb, Georgy; Falk, Robert; El-Ghar, Mohamed Abou

    2011-01-01

    An alternative method of diagnosing malignant lung nodules by their shape, rather than conventional growth rate, is proposed. The 3D surfaces of the detected lung nodules are delineated by spherical harmonic analysis that represents a 3D surface of the lung nodule supported by the unit sphere with a linear combination of special basis functions, called Spherical Harmonics (SHs). The proposed 3D shape analysis is carried out in five steps: (i) 3D lung nodule segmentation with a deformable 3D boundary controlled by a new prior visual appearance model; (ii) 3D Delaunay triangulation to construct a 3D mesh model of the segmented lung nodule surface; (iii) mapping this model to the unit sphere; (iv) computing the SHs for the surface; and (v) determining the number of the SHs to delineate the lung nodule. We describe the lung nodule shape complexity with a new shape index, the estimated number of the SHs, and use it for the K-nearest classification into malignant and benign lung nodules. Preliminary experiments on 327 lung nodules (153 malignant and 174 benign) resulted in a classification accuracy of 93.6%, showing that the proposed method is a promising supplement to current technologies for the early diagnosis of lung cancer.

  2. 3D shape analysis for early diagnosis of malignant lung nodules.

    PubMed

    El-Bazl, Ayman; Nitzken, Matthew; Khalifa, Fahmi; Elnakib, Ahmed; Gimel'farb, Georgy; Falk, Robert; El-Ghar, Mohammed Abo

    2011-01-01

    An alternative method for diagnosing malignant lung nodules by their shape rather than conventional growth rate is proposed. The 3D surfaces of the detected lung nodules are delineated by spherical harmonic analysis, which represents a 3D surface of the lung nodule supported by the unit sphere with a linear combination of special basis functions, called spherical harmonics (SHs). The proposed 3D shape analysis is carried out in five steps: (i) 3D lung nodule segmentation with a deformable 3D boundary controlled by two probabilistic visual appearance models (the learned prior and the estimated current appearance one); (ii) 3D Delaunay triangulation to construct a 3D mesh model of the segmented lung nodule surface; (iii) mapping this model to the unit sphere; (iv) computing the SHs for the surface, and (v) determining the number of the SHs to delineate the lung nodule. We describe the lung nodule shape complexity with a new shape index, the estimated number of the SHs, and use it for the K-nearest classification to distinguish malignant and benign lung nodules. Preliminary experiments on 327 lung nodules (153 malignant and 174 benign) resulted in the 93.6% correct classification (for the 95% confidence interval), showing that the proposed method is a promising supplement to current technologies for the early diagnosis of lung cancer.

  3. Analysis of Gait Disturbance in Glut 1 Deficiency Syndrome.

    PubMed

    Blumenschine, Michelle; Montes, Jacqueline; Rao, Ashwini K; Engelstad, Kristin; De Vivo, Darryl C

    2016-11-01

    Anticipating potential therapies for Glut 1 deficiency syndrome (Glut1DS) emphasizes the need for effective clinical outcome measures. The 6-minute walk test is a well-established outcome measure that evaluates walking ability in neurological diseases. Twenty-one children with Glut 1 deficiency syndrome and 21 controls performed the 6-minute walk test. Fatigue was determined by comparing distance walked in the first and sixth minutes. Gait was analyzed by stride length, velocity, cadence, base of support, and percentage time in double support. Independent sample t-tests examined differences between group. Repeated-measures analysis of variance evaluated gait parameters over time. Glut 1 deficiency syndrome patients walked less (P < .05), had slower velocities (P < .0001), had shorter stride lengths (P < .0001), spent more time in double support (P < .001), and had increasing variability in base of support (P = .009). Glut 1 deficiency syndrome patients have impaired motor performance, walk more slowly, and have poor balance. The 6-minute walk test with gait analysis may serve as a useful outcome measure in clinical trials in Glut 1 deficiency syndrome.

  4. Intra-individual gait pattern variability in specific situations: Implications for forensic gait analysis.

    PubMed

    Ludwig, Oliver; Dillinger, Steffen; Marschall, Franz

    2016-07-01

    In this study, inter- and intra-individual gait pattern differences are examined in various gait situations by means of phase diagrams of the extremity angles (cyclograms). 8 test subjects walked along a walking distance of 6m under different conditions three times each: barefoot, wearing sneakers, wearing combat boots, after muscular fatigue, and wearing a full-face motorcycle helmet restricting vision. The joint angles of foot, knee, and hip were recorded in the sagittal plane. The coupling of movements was represented by time-adjusted cyclograms, and the inter- and intra-individual differences were captured by calculating the similarity between different gait patterns. Gait pattern variability was often greater between the defined test situations than between the individual test subjects. The results have been interpreted considering neurophysiological regulation mechanisms. Footwear, masking, and fatigue were interpreted as disturbance parameters, each being a cause for gait pattern variability and complicating the inference of identity of persons in video recordings.

  5. Analysis of the 3D distribution of stacked self-assembled quantum dots by electron tomography

    PubMed Central

    2012-01-01

    The 3D distribution of self-assembled stacked quantum dots (QDs) is a key parameter to obtain the highest performance in a variety of optoelectronic devices. In this work, we have measured this distribution in 3D using a combined procedure of needle-shaped specimen preparation and electron tomography. We show that conventional 2D measurements of the distribution of QDs are not reliable, and only 3D analysis allows an accurate correlation between the growth design and the structural characteristics. PMID:23249477

  6. An Inverse Kinematic Approach Using Groebner Basis Theory Applied to Gait Cycle Analysis

    DTIC Science & Technology

    2013-03-01

    AN INVERSE KINEMATIC APPROACH USING GROEBNER BASIS THEORY APPLIED TO GAIT CYCLE ANALYSIS THESIS Anum Barki AFIT-ENP-13-M-02 DEPARTMENT OF THE AIR...copyright protection in the United States. AFIT-ENP-13-M-02 AN INVERSE KINEMATIC APPROACH USING GROEBNER BASIS THEORY APPLIED TO GAIT CYCLE ANALYSIS THESIS...APPROACH USING GROEBNER BASIS THEORY APPLIED TO GAIT CYCLE ANALYSIS Anum Barki, BS Approved: Dr. Ronald F. Tuttle (Chairman) Date Dr. Kimberly Kendricks

  7. Mobile 3D quality of experience evaluation: a hybrid data collection and analysis approach

    NASA Astrophysics Data System (ADS)

    Utriainen, Timo; Häyrynen, Jyrki; Jumisko-Pyykkö, Satu; Boev, Atanas; Gotchev, Atanas; Hannuksela, Miska M.

    2011-02-01

    The paper presents a hybrid approach to study the user's experienced quality of 3D visual content on mobile autostereoscopic displays. It combines extensive subjective tests with collection and objective analysis of eye-tracked data. 3D cues which are significant for mobiles are simulated in the generated 3D test content. The methodology for conducting subjective quality evaluation includes hybrid data-collection of quantitative quality preferences, qualitative impressions, and binocular eye-tracking. We present early results of the subjective tests along with eye movement reaction times, areas of interest and heatmaps obtained from raw eye-tracked data after statistical analysis. The study contributes to the question what is important to be visualized on portable auto-stereoscopic displays and how to maintain and visually enhance the quality of 3D content for such displays.

  8. Classification of gait kinematics of anterior cruciate ligament reconstructed subjects using principal component analysis and regressions modelling.

    PubMed

    Leporace, Gustavo; Batista, Luiz Alberto; Muniz, Adriane M; Zeitoune, Gabriel; Luciano, Thiago; Metsavaht, Leonardo; Nadal, Jurandir

    2012-01-01

    The aim of this study was to compare the knee kinematics of anterior cruciate ligament reconstructed (ACL-R) and healthy subjects (CG) during gait and classify the status of normality. Ten healthy and six ACL-R subjects had their gait analyzed at 60 fps. 3D knee angles were calculated and inserted into three separate matrices used to perform the principal component (PC) analysis. The scores of PCs retained in each analysis were used to calculate the standard distances (SD) of each participant in relation to the center of the CG. The PC scores of the three planes were used in a logistic regression to define normality. In the sagittal plane there was no difference between groups. In the frontal and transverse planes ACL-R subjects showed higher SD values than CG. PCs identified that ACL-R subjects showed increased adduction, internal and external rotation. All these subjects had their gait classified as abnormal by logistic regression. Therefore, in the studied ACL-R subjects the gait pattern did not return to normal levels after surgery. This may lead to degenerative injuries, as osteoarthritis, in the future.

  9. Sensitivity Analysis of the Scattering-Based SARBM3D Despeckling Algorithm

    PubMed Central

    Di Simone, Alessio

    2016-01-01

    Synthetic Aperture Radar (SAR) imagery greatly suffers from multiplicative speckle noise, typical of coherent image acquisition sensors, such as SAR systems. Therefore, a proper and accurate despeckling preprocessing step is almost mandatory to aid the interpretation and processing of SAR data by human users and computer algorithms, respectively. Very recently, a scattering-oriented version of the popular SAR Block-Matching 3D (SARBM3D) despeckling filter, named Scattering-Based (SB)-SARBM3D, was proposed. The new filter is based on the a priori knowledge of the local topography of the scene. In this paper, an experimental sensitivity analysis of the above-mentioned despeckling algorithm is carried out, and the main results are shown and discussed. In particular, the role of both electromagnetic and geometrical parameters of the surface and the impact of its scattering behavior are investigated. Furthermore, a comprehensive sensitivity analysis of the SB-SARBM3D filter against the Digital Elevation Model (DEM) resolution and the SAR image-DEM coregistration step is also provided. The sensitivity analysis shows a significant robustness of the algorithm against most of the surface parameters, while the DEM resolution plays a key role in the despeckling process. Furthermore, the SB-SARBM3D algorithm outperforms the original SARBM3D in the presence of the most realistic scattering behaviors of the surface. An actual scenario is also presented to assess the DEM role in real-life conditions. PMID:27347971

  10. 3D texture analysis in renal cell carcinoma tissue image grading.

    PubMed

    Kim, Tae-Yun; Cho, Nam-Hoon; Jeong, Goo-Bo; Bengtsson, Ewert; Choi, Heung-Kook

    2014-01-01

    One of the most significant processes in cancer cell and tissue image analysis is the efficient extraction of features for grading purposes. This research applied two types of three-dimensional texture analysis methods to the extraction of feature values from renal cell carcinoma tissue images, and then evaluated the validity of the methods statistically through grade classification. First, we used a confocal laser scanning microscope to obtain image slices of four grades of renal cell carcinoma, which were then reconstructed into 3D volumes. Next, we extracted quantitative values using a 3D gray level cooccurrence matrix (GLCM) and a 3D wavelet based on two types of basis functions. To evaluate their validity, we predefined 6 different statistical classifiers and applied these to the extracted feature sets. In the grade classification results, 3D Haar wavelet texture features combined with principal component analysis showed the best discrimination results. Classification using 3D wavelet texture features was significantly better than 3D GLCM, suggesting that the former has potential for use in a computer-based grading system.

  11. Sensitivity Analysis of the Scattering-Based SARBM3D Despeckling Algorithm.

    PubMed

    Di Simone, Alessio

    2016-06-25

    Synthetic Aperture Radar (SAR) imagery greatly suffers from multiplicative speckle noise, typical of coherent image acquisition sensors, such as SAR systems. Therefore, a proper and accurate despeckling preprocessing step is almost mandatory to aid the interpretation and processing of SAR data by human users and computer algorithms, respectively. Very recently, a scattering-oriented version of the popular SAR Block-Matching 3D (SARBM3D) despeckling filter, named Scattering-Based (SB)-SARBM3D, was proposed. The new filter is based on the a priori knowledge of the local topography of the scene. In this paper, an experimental sensitivity analysis of the above-mentioned despeckling algorithm is carried out, and the main results are shown and discussed. In particular, the role of both electromagnetic and geometrical parameters of the surface and the impact of its scattering behavior are investigated. Furthermore, a comprehensive sensitivity analysis of the SB-SARBM3D filter against the Digital Elevation Model (DEM) resolution and the SAR image-DEM coregistration step is also provided. The sensitivity analysis shows a significant robustness of the algorithm against most of the surface parameters, while the DEM resolution plays a key role in the despeckling process. Furthermore, the SB-SARBM3D algorithm outperforms the original SARBM3D in the presence of the most realistic scattering behaviors of the surface. An actual scenario is also presented to assess the DEM role in real-life conditions.

  12. Lead-oriented synthesis: Investigation of organolithium-mediated routes to 3-D scaffolds and 3-D shape analysis of a virtual lead-like library.

    PubMed

    Lüthy, Monique; Wheldon, Mary C; Haji-Cheteh, Chehasnah; Atobe, Masakazu; Bond, Paul S; O'Brien, Peter; Hubbard, Roderick E; Fairlamb, Ian J S

    2015-06-01

    Synthetic routes to six 3-D scaffolds containing piperazine, pyrrolidine and piperidine cores have been developed. The synthetic methodology focused on the use of N-Boc α-lithiation-trapping chemistry. Notably, suitably protected and/or functionalised medicinal chemistry building blocks were synthesised via concise, connective methodology. This represents a rare example of lead-oriented synthesis. A virtual library of 190 compounds was then enumerated from the six scaffolds. Of these, 92 compounds (48%) fit the lead-like criteria of: (i) -1⩽AlogP⩽3; (ii) 14⩽number of heavy atoms⩽26; (iii) total polar surface area⩾50Å(2). The 3-D shapes of the 190 compounds were analysed using a triangular plot of normalised principal moments of inertia (PMI). From this, 46 compounds were identified which had lead-like properties and possessed 3-D shapes in under-represented areas of pharmaceutical space. Thus, the PMI analysis of the 190 member virtual library showed that whilst scaffolds which may appear on paper to be 3-D in shape, only 24% of the compounds actually had 3-D structures in the more interesting areas of 3-D drug space.

  13. 3D video analysis of the novel object recognition test in rats.

    PubMed

    Matsumoto, Jumpei; Uehara, Takashi; Urakawa, Susumu; Takamura, Yusaku; Sumiyoshi, Tomiki; Suzuki, Michio; Ono, Taketoshi; Nishijo, Hisao

    2014-10-01

    The novel object recognition (NOR) test has been widely used to test memory function. We developed a 3D computerized video analysis system that estimates nose contact with an object in Long Evans rats to analyze object exploration during NOR tests. The results indicate that the 3D system reproducibly and accurately scores the NOR test. Furthermore, the 3D system captures a 3D trajectory of the nose during object exploration, enabling detailed analyses of spatiotemporal patterns of object exploration. The 3D trajectory analysis revealed a specific pattern of object exploration in the sample phase of the NOR test: normal rats first explored the lower parts of objects and then gradually explored the upper parts. A systematic injection of MK-801 suppressed changes in these exploration patterns. The results, along with those of previous studies, suggest that the changes in the exploration patterns reflect neophobia to a novel object and/or changes from spatial learning to object learning. These results demonstrate that the 3D tracking system is useful not only for detailed scoring of animal behaviors but also for investigation of characteristic spatiotemporal patterns of object exploration. The system has the potential to facilitate future investigation of neural mechanisms underlying object exploration that result from dynamic and complex brain activity.

  14. [Detrended cross-correlation analysis: a new method for gait signal analysis].

    PubMed

    Wang, Pingping; Wang, Jun

    2012-12-01

    The cross-correlation of gait signal can mirror the health situations of different people. It is important to analyze the long-range cross correlations of the two signals of nonstationarity for medical research. In this paper, we propose a detrended cross-correlation analysis (DCCA) method for analyzing the different gait signal in physiological and pathological conditions. Our work dealt with three kinds of gait signals, including those of normal young people (23 to 29 years of age), those of healthy old people (71 to 77 years of age) and those of the old people (60 to 77 years of age) with Parkinson's disease from the MIT-BIH database. We carried out the DCCA for the three gait signals of nonstationarity. The results showed that the self-similarity of gait signal got more unstable with the age increasing and health status worsening. From the cross-correlation analysis, we found that the cross-correlation degree of gait signal of young people increased gradually, the healthy old people changed slowly and the Parkinson's disease patients showed unstable changes. We can make medical diagnosis and treatment according to the differences among different gait signals.

  15. Analysis of scalability of high-performance 3D image processing platform for virtual colonoscopy

    PubMed Central

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli

    2014-01-01

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. For this purpose, we previously developed a software platform for high-performance 3D medical image processing, called HPC 3D-MIP platform, which employs increasingly available and affordable commodity computing systems such as the multicore, cluster, and cloud computing systems. To achieve scalable high-performance computing, the platform employed size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D-MIP algorithms, supported task scheduling for efficient load distribution and balancing, and consisted of a layered parallel software libraries that allow image processing applications to share the common functionalities. We evaluated the performance of the HPC 3D-MIP platform by applying it to computationally intensive processes in virtual colonoscopy. Experimental results showed a 12-fold performance improvement on a workstation with 12-core CPUs over the original sequential implementation of the processes, indicating the efficiency of the platform. Analysis of performance scalability based on the Amdahl’s law for symmetric multicore chips showed the potential of a high performance scalability of the HPC 3D-MIP platform when a larger number of cores is available. PMID:24910506

  16. Quantitative comparison of 3D and 2.5D gamma analysis: introducing gamma angle histograms

    NASA Astrophysics Data System (ADS)

    Sa'd, M. Al; Graham, J.; Liney, G. P.; Moore, C. J.

    2013-04-01

    Comparison of dose distributions using the 3D gamma method is anticipated to provide better indicators for the quality assurance process than the 2.5D (stacked 2D slice-by-slice) gamma calculation, especially for advanced radiotherapy technologies. This study compares the accuracy of the 3D and 2.5D gamma calculation methods. 3D and 2.5D gamma calculations were carried out on four reference/evaluation 3D dose sample pairs. A number of analysis methods were used, including average gamma and gamma volume histograms. We introduce the concept of gamma-angle histograms. Noise sensitivity tests were also performed using two different noise models. The advantage of the 3D gamma method showed up as a higher proportion of points passing the tolerance criteria of 3% dose difference and 3 mm distance-to-agreement (DTA), with considerably lower average gamma values, a lower influence of the DTA criterion, and a higher noise tolerance. The 3D gamma approach is more reliable than the 2.5D approach in terms of providing comprehensive quantitative results, which are needed in quality assurance procedures for advanced radiotherapy methods.

  17. 3D finite element analysis of porous Ti-based alloy prostheses.

    PubMed

    Mircheski, Ile; Gradišar, Marko

    2016-11-01

    In this paper, novel designs of porous acetabular cups are created and tested with 3D finite element analysis (FEA). The aim is to develop a porous acetabular cup with low effective radial stiffness of the structure, which will be near to the architectural and mechanical behavior of the natural bone. For the realization of this research, a 3D-scanner technology was used for obtaining a 3D-CAD model of the pelvis bone, a 3D-CAD software for creating a porous acetabular cup, and a 3D-FEA software for virtual testing of a novel design of the porous acetabular cup. The results obtained from this research reveal that a porous acetabular cup from Ti-based alloys with 60 ± 5% porosity has the mechanical behavior and effective radial stiffness (Young's modulus in radial direction) that meet and exceed the required properties of the natural bone. The virtual testing with 3D-FEA of a novel design with porous structure during the very early stage of the design and the development of orthopedic implants, enables obtaining a new or improved biomedical implant for a relatively short time and reduced price.

  18. Fully-coupled analysis of jet mixing problems. Three-dimensional PNS model, SCIP3D

    NASA Technical Reports Server (NTRS)

    Wolf, D. E.; Sinha, N.; Dash, S. M.

    1988-01-01

    Numerical procedures formulated for the analysis of 3D jet mixing problems, as incorporated in the computer model, SCIP3D, are described. The overall methodology closely parallels that developed in the earlier 2D axisymmetric jet mixing model, SCIPVIS. SCIP3D integrates the 3D parabolized Navier-Stokes (PNS) jet mixing equations, cast in mapped cartesian or cylindrical coordinates, employing the explicit MacCormack Algorithm. A pressure split variant of this algorithm is employed in subsonic regions with a sublayer approximation utilized for treating the streamwise pressure component. SCIP3D contains both the ks and kW turbulence models, and employs a two component mixture approach to treat jet exhausts of arbitrary composition. Specialized grid procedures are used to adjust the grid growth in accordance with the growth of the jet, including a hybrid cartesian/cylindrical grid procedure for rectangular jets which moves the hybrid coordinate origin towards the flow origin as the jet transitions from a rectangular to circular shape. Numerous calculations are presented for rectangular mixing problems, as well as for a variety of basic unit problems exhibiting overall capabilities of SCIP3D.

  19. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator

    PubMed Central

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B.; van Dieën, Jaap H.

    2016-01-01

    Gait analysis can provide valuable information on a person’s condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars—related to the user condition—and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation. PMID:27834911

  20. On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator.

    PubMed

    Ballesteros, Joaquin; Urdiales, Cristina; Martinez, Antonio B; van Dieën, Jaap H

    2016-11-10

    Gait analysis can provide valuable information on a person's condition and rehabilitation progress. Gait is typically captured using external equipment and/or wearable sensors. These tests are largely constrained to specific controlled environments. In addition, gait analysis often requires experts for calibration, operation and/or to place sensors on volunteers. Alternatively, mobility support devices like rollators can be equipped with onboard sensors to monitor gait parameters, while users perform their Activities of Daily Living. Gait analysis in rollators may use odometry and force sensors in the handlebars. However, force based estimation of gait parameters is less accurate than traditional methods, especially when rollators are not properly used. This paper presents an evaluation of force based gait analysis using a smart rollator on different groups of users to determine when this methodology is applicable. In a second stage, the rollator is used in combination with two lab-based gait analysis systems to assess the rollator estimation error. Our results show that: (i) there is an inverse relation between the variance in the force difference between handlebars and support on the handlebars-related to the user condition-and the estimation error; and (ii) this error is lower than 10% when the variation in the force difference is above 7 N. This lower limit was exceeded by the 95.83% of our challenged volunteers. In conclusion, rollators are useful for gait characterization as long as users really need the device for ambulation.

  1. Accelerometry-based gait analysis, an additional objective approach to screen subjects at risk for falling.

    PubMed

    Senden, R; Savelberg, H H C M; Grimm, B; Heyligers, I C; Meijer, K

    2012-06-01

    This study investigated whether the Tinetti scale, as a subjective measure for fall risk, is associated with objectively measured gait characteristics. It is studied whether gait parameters are different for groups that are stratified for fall risk using the Tinetti scale. Moreover, the discriminative power of gait parameters to classify elderly according to the Tinetti scale is investigated. Gait of 50 elderly with a Tinneti>24 and 50 elderly with a Tinetti≤24 was analyzed using acceleration-based gait analysis. Validated algorithms were used to derive spatio-temporal gait parameters, harmonic ratio, inter-stride amplitude variability and root mean square (RMS) from the accelerometer data. Clear differences in gait were found between the groups. All gait parameters correlated with the Tinetti scale (r-range: 0.20-0.73). Only walking speed, step length and RMS showed moderate to strong correlations and high discriminative power to classify elderly according to the Tinetti scale. It is concluded that subtle gait changes that have previously been related to fall risk are not captured by the subjective assessment. It is therefore worthwhile to include objective gait assessment in fall risk screening.

  2. Visualization and analysis of 3D gene expression patterns in zebrafish using web services

    NASA Astrophysics Data System (ADS)

    Potikanond, D.; Verbeek, F. J.

    2012-01-01

    The analysis of patterns of gene expression patterns analysis plays an important role in developmental biology and molecular genetics. Visualizing both quantitative and spatio-temporal aspects of gene expression patterns together with referenced anatomical structures of a model-organism in 3D can help identifying how a group of genes are expressed at a certain location at a particular developmental stage of an organism. In this paper, we present an approach to provide an online visualization of gene expression data in zebrafish (Danio rerio) within 3D reconstruction model of zebrafish in different developmental stages. We developed web services that provide programmable access to the 3D reconstruction data and spatial-temporal gene expression data maintained in our local repositories. To demonstrate this work, we develop a web application that uses these web services to retrieve data from our local information systems. The web application also retrieve relevant analysis of microarray gene expression data from an external community resource; i.e. the ArrayExpress Atlas. All the relevant gene expression patterns data are subsequently integrated with the reconstruction data of the zebrafish atlas using ontology based mapping. The resulting visualization provides quantitative and spatial information on patterns of gene expression in a 3D graphical representation of the zebrafish atlas in a certain developmental stage. To deliver the visualization to the user, we developed a Java based 3D viewer client that can be integrated in a web interface allowing the user to visualize the integrated information over the Internet.

  3. Method of Individual Adjustment for 3D CT Analysis: Linear Measurement.

    PubMed

    Kim, Dong Kyu; Choi, Dong Hun; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae; Choi, Kang Young

    2016-01-01

    Introduction. We aim to regularize measurement values in three-dimensional (3D) computed tomography (CT) reconstructed images for higher-precision 3D analysis, focusing on length-based 3D cephalometric examinations. Methods. We measure the linear distances between points on different skull models using Vernier calipers (real values). We use 10 differently tilted CT scans for 3D CT reconstruction of the models and measure the same linear distances from the picture archiving and communication system (PACS). In both cases, each measurement is performed three times by three doctors, yielding nine measurements. The real values are compared with the PACS values. Each PACS measurement is revised based on the display field of view (DFOV) values and compared with the real values. Results. The real values and the PACS measurement changes according to tilt value have no significant correlations (p > 0.05). However, significant correlations appear between the real values and DFOV-adjusted PACS measurements (p < 0.001). Hence, we obtain a correlation expression that can yield real physical values from PACS measurements. The DFOV value intervals for various age groups are also verified. Conclusion. Precise confirmation of individual preoperative length and precise analysis of postoperative improvements through 3D analysis is possible, which is helpful for facial-bone-surgery symmetry correction.

  4. Method of Individual Adjustment for 3D CT Analysis: Linear Measurement

    PubMed Central

    Choi, Dong Hun; Lee, Jeong Woo; Yang, Jung Dug; Chung, Ho Yun; Cho, Byung Chae

    2016-01-01

    Introduction. We aim to regularize measurement values in three-dimensional (3D) computed tomography (CT) reconstructed images for higher-precision 3D analysis, focusing on length-based 3D cephalometric examinations. Methods. We measure the linear distances between points on different skull models using Vernier calipers (real values). We use 10 differently tilted CT scans for 3D CT reconstruction of the models and measure the same linear distances from the picture archiving and communication system (PACS). In both cases, each measurement is performed three times by three doctors, yielding nine measurements. The real values are compared with the PACS values. Each PACS measurement is revised based on the display field of view (DFOV) values and compared with the real values. Results. The real values and the PACS measurement changes according to tilt value have no significant correlations (p > 0.05). However, significant correlations appear between the real values and DFOV-adjusted PACS measurements (p < 0.001). Hence, we obtain a correlation expression that can yield real physical values from PACS measurements. The DFOV value intervals for various age groups are also verified. Conclusion. Precise confirmation of individual preoperative length and precise analysis of postoperative improvements through 3D analysis is possible, which is helpful for facial-bone-surgery symmetry correction. PMID:28070517

  5. Spatial and temporal analysis of DIII-D 3D magnetic diagnostic data

    NASA Astrophysics Data System (ADS)

    Strait, E. J.; King, J. D.; Hanson, J. M.; Logan, N. C.

    2016-11-01

    An extensive set of magnetic diagnostics in DIII-D is aimed at measuring non-axisymmetric "3D" features of tokamak plasmas, with typical amplitudes ˜10-3 to 10-5 of the total magnetic field. We describe hardware and software techniques used at DIII-D to condition the individual signals and analysis to estimate the spatial structure from an ensemble of discrete measurements. Applications of the analysis include detection of non-rotating MHD instabilities, plasma control, and validation of MHD stability and 3D equilibrium models.

  6. Spatial and temporal analysis of DIII-D 3D magnetic diagnostic data.

    PubMed

    Strait, E J; King, J D; Hanson, J M; Logan, N C

    2016-11-01

    An extensive set of magnetic diagnostics in DIII-D is aimed at measuring non-axisymmetric "3D" features of tokamak plasmas, with typical amplitudes ∼10(-3) to 10(-5) of the total magnetic field. We describe hardware and software techniques used at DIII-D to condition the individual signals and analysis to estimate the spatial structure from an ensemble of discrete measurements. Applications of the analysis include detection of non-rotating MHD instabilities, plasma control, and validation of MHD stability and 3D equilibrium models.

  7. Spatial and temporal analysis of DIII-D 3D magnetic diagnostic data

    DOE PAGES

    Strait, E. J.; King, J. D.; Hanson, J. M.; ...

    2016-08-11

    An extensive set of magnetic diagnostics in DIII-D is aimed at measuring non-axisymmetric "3D" features of tokamak plasmas, with typical amplitudes ~10-3 to 10-5 of the total magnetic field. We describe hardware and software techniques used at DIII-D to condition the individual signals and analysis to estimate the spatial structure from an ensemble of discrete measurements. Lastly, applications of the analysis include detection of non-rotating MHD instabilities, plasma control, and validation of MHD stability and 3D equilibrium models.

  8. A spatiotemporal analysis of gait freezing and the impact of pedunculopontine nucleus stimulation.

    PubMed

    Thevathasan, Wesley; Cole, Michael H; Graepel, Cara L; Hyam, Jonathan A; Jenkinson, Ned; Brittain, John-Stuart; Coyne, Terry J; Silburn, Peter A; Aziz, Tipu Z; Kerr, Graham; Brown, Peter

    2012-05-01

    Gait freezing is an episodic arrest of locomotion due to an inability to take normal steps. Pedunculopontine nucleus stimulation is an emerging therapy proposed to improve gait freezing, even where refractory to medication. However, the efficacy and precise effects of pedunculopontine nucleus stimulation on Parkinsonian gait disturbance are not established. The clinical application of this new therapy is controversial and it is unknown if bilateral stimulation is more effective than unilateral. Here, in a double-blinded study using objective spatiotemporal gait analysis, we assessed the impact of unilateral and bilateral pedunculopontine nucleus stimulation on triggered episodes of gait freezing and on background deficits of unconstrained gait in Parkinson's disease. Under experimental conditions, while OFF medication, Parkinsonian patients with severe gait freezing implanted with pedunculopontine nucleus stimulators below the pontomesencephalic junction were assessed during three conditions; off stimulation, unilateral stimulation and bilateral stimulation. Results were compared to Parkinsonian patients without gait freezing matched for disease severity and healthy controls. Pedunculopontine nucleus stimulation improved objective measures of gait freezing, with bilateral stimulation more effective than unilateral. During unconstrained walking, Parkinsonian patients who experience gait freezing had reduced step length and increased step length variability compared to patients without gait freezing; however, these deficits were unchanged by pedunculopontine nucleus stimulation. Chronic pedunculopontine nucleus stimulation improved Freezing of Gait Questionnaire scores, reflecting a reduction of the freezing encountered in patients' usual environments and medication states. This study provides objective, double-blinded evidence that in a specific subgroup of Parkinsonian patients, stimulation of a caudal pedunculopontine nucleus region selectively improves gait

  9. Gait analysis using gravitational acceleration measured by wearable sensors.

    PubMed

    Takeda, Ryo; Tadano, Shigeru; Todoh, Masahiro; Morikawa, Manabu; Nakayasu, Minoru; Yoshinari, Satoshi

    2009-02-09

    A novel method for measuring human gait posture using wearable sensor units is proposed. The sensor units consist of a tri-axial acceleration sensor and three gyro sensors aligned on three axes. The acceleration and angular velocity during walking were measured with seven sensor units worn on the abdomen and the lower limb segments (both thighs, shanks and feet). The three-dimensional positions of each joint are calculated from each segment length and joint angle. Joint angle can be estimated mechanically from the gravitational acceleration along the anterior axis of the segment. However, the acceleration data during walking includes three major components; translational acceleration, gravitational acceleration and external noise. Therefore, an optimization analysis was represented to separate only the gravitational acceleration from the acceleration data. Because the cyclic patterns of acceleration data can be found during constant walking, a FFT analysis was applied to obtain some characteristic frequencies in it. A pattern of gravitational acceleration was assumed using some parts of these characteristic frequencies. Every joint position was calculated from the pattern under the condition of physiological motion range of each joint. An optimized pattern of the gravitational acceleration was selected as a solution of an inverse problem. Gaits of three healthy volunteers were measured by walking for 20s on a flat floor. As a result, the acceleration data of every segment was measured simultaneously. The characteristic three-dimensional walking could be shown by the expression using a stick figure model. In addition, the trajectories of the knee joint in the horizontal plane could be checked by visual imaging on a PC. Therefore, this method provides important quantitive information for gait diagnosis.

  10. Kinematic Analysis Quantifies Gait Abnormalities Associated with Lameness in Broiler Chickens and Identifies Evolutionary Gait Differences

    PubMed Central

    Caplen, Gina; Hothersall, Becky; Murrell, Joanna C.; Nicol, Christine J.; Waterman-Pearson, Avril E.; Weeks, Claire A.; Colborne, G. Robert

    2012-01-01

    This is the first time that gait characteristics of broiler (meat) chickens have been compared with their progenitor, jungle fowl, and the first kinematic study to report a link between broiler gait parameters and defined lameness scores. A commercial motion-capturing system recorded three-dimensional temporospatial information during walking. The hypothesis was that the gait characteristics of non-lame broilers (n = 10) would be intermediate to those of lame broilers (n = 12) and jungle fowl (n = 10, tested at two ages: immature and adult). Data analysed using multi-level models, to define an extensive range of baseline gait parameters, revealed inter-group similarities and differences. Natural selection is likely to have made jungle fowl walking gait highly efficient. Modern broiler chickens possess an unbalanced body conformation due to intense genetic selection for additional breast muscle (pectoral hypertrophy) and whole body mass. Together with rapid growth, this promotes compensatory gait adaptations to minimise energy expenditure and triggers high lameness prevalence within commercial flocks; lameness creating further disruption to the gait cycle and being an important welfare issue. Clear differences were observed between the two lines (short stance phase, little double-support, low leg lift, and little back displacement in adult jungle fowl; much double-support, high leg lift, and substantial vertical back movement in sound broilers) presumably related to mass and body conformation. Similarities included stride length and duration. Additional modifications were also identified in lame broilers (short stride length and duration, substantial lateral back movement, reduced velocity) presumably linked to musculo-skeletal abnormalities. Reduced walking velocity suggests an attempt to minimise skeletal stress and/or discomfort, while a shorter stride length and time, together with longer stance and double-support phases, are associated with

  11. 3D shape measurement of shoeprint impression with structured illumination and fringe pattern analysis

    NASA Astrophysics Data System (ADS)

    Su, Xianyu; Cao, Yiping; Xiang, Liqun; Chen, Wenjing

    2002-06-01

    The shoeprint impressions of suspect left at the crime scene can sometimes tell investigators what type of shoes to be looked for. These shoeprint impressions as one of the important evidence are useful in the detection of criminals. In this paper we propose a novel technique for identifying and analyzing the 3D characteristics of shoeprint impressions. We also design 3D shoeprint impression analysis system based on the combination the 3D shape measurement with structured illumination and fringe pattern analysis. We give a detail discussion on the principle and configuration of the system. Laboratory experiments show the technique is efficient in the detection of shoeprint and in the offering the reference for judicial evidence.

  12. Analysis of 3-D images of dental imprints using computer vision

    NASA Astrophysics Data System (ADS)

    Aubin, Michele; Cote, Jean; Laurendeau, Denis; Poussart, Denis

    1992-05-01

    This paper addressed two important aspects of dental analysis: (1) location and (2) identification of the types of teeth by means of 3-D image acquisition and segmentation. The 3-D images of both maxillaries are acquired using a wax wafer as support. The interstices between teeth are detected by non-linear filtering of the 3-D and grey-level data. Two operators are presented: one for the detection of the interstices between incisors, canines, and premolars and one for those between molars. Teeth are then identified by mapping the imprint under analysis on the computer model of an 'ideal' imprint. For the mapping to be valid, a set of three reference points is detected on the imprint. Then, the points are put in correspondence with similar points on the model. Two such points are chosen based on a least-squares fit of a second-order polynomial of the 3-D data in the area of canines. This area is of particular interest since the canines show a very characteristic shape and are easily detected on the imprint. The mapping technique is described in detail in the paper as well as pre-processing of the 3-D profiles. Experimental results are presented for different imprints.

  13. 3D texture analysis for classification of second harmonic generation images of human ovarian cancer

    PubMed Central

    Wen, Bruce; Campbell, Kirby R.; Tilbury, Karissa; Nadiarnykh, Oleg; Brewer, Molly A.; Patankar, Manish; Singh, Vikas; Eliceiri, Kevin. W.; Campagnola, Paul J.

    2016-01-01

    Remodeling of the collagen architecture in the extracellular matrix (ECM) has been implicated in ovarian cancer. To quantify these alterations we implemented a form of 3D texture analysis to delineate the fibrillar morphology observed in 3D Second Harmonic Generation (SHG) microscopy image data of normal (1) and high risk (2) ovarian stroma, benign ovarian tumors (3), low grade (4) and high grade (5) serous tumors, and endometrioid tumors (6). We developed a tailored set of 3D filters which extract textural features in the 3D image sets to build (or learn) statistical models of each tissue class. By applying k-nearest neighbor classification using these learned models, we achieved 83–91% accuracies for the six classes. The 3D method outperformed the analogous 2D classification on the same tissues, where we suggest this is due the increased information content. This classification based on ECM structural changes will complement conventional classification based on genetic profiles and can serve as an additional biomarker. Moreover, the texture analysis algorithm is quite general, as it does not rely on single morphological metrics such as fiber alignment, length, and width but their combined convolution with a customizable basis set. PMID:27767180

  14. 3D texture analysis for classification of second harmonic generation images of human ovarian cancer

    NASA Astrophysics Data System (ADS)

    Wen, Bruce; Campbell, Kirby R.; Tilbury, Karissa; Nadiarnykh, Oleg; Brewer, Molly A.; Patankar, Manish; Singh, Vikas; Eliceiri, Kevin. W.; Campagnola, Paul J.

    2016-10-01

    Remodeling of the collagen architecture in the extracellular matrix (ECM) has been implicated in ovarian cancer. To quantify these alterations we implemented a form of 3D texture analysis to delineate the fibrillar morphology observed in 3D Second Harmonic Generation (SHG) microscopy image data of normal (1) and high risk (2) ovarian stroma, benign ovarian tumors (3), low grade (4) and high grade (5) serous tumors, and endometrioid tumors (6). We developed a tailored set of 3D filters which extract textural features in the 3D image sets to build (or learn) statistical models of each tissue class. By applying k-nearest neighbor classification using these learned models, we achieved 83–91% accuracies for the six classes. The 3D method outperformed the analogous 2D classification on the same tissues, where we suggest this is due the increased information content. This classification based on ECM structural changes will complement conventional classification based on genetic profiles and can serve as an additional biomarker. Moreover, the texture analysis algorithm is quite general, as it does not rely on single morphological metrics such as fiber alignment, length, and width but their combined convolution with a customizable basis set.

  15. Application of multi-resolution 3D techniques in crime scene documentation with bloodstain pattern analysis.

    PubMed

    Hołowko, Elwira; Januszkiewicz, Kamil; Bolewicki, Paweł; Sitnik, Robert; Michoński, Jakub

    2016-10-01

    In forensic documentation with bloodstain pattern analysis (BPA) it is highly desirable to obtain non-invasively overall documentation of a crime scene, but also register in high resolution single evidence objects, like bloodstains. In this study, we propose a hierarchical 3D scanning platform designed according to the top-down approach known from the traditional forensic photography. The overall 3D model of a scene is obtained via integration of laser scans registered from different positions. Some parts of a scene being particularly interesting are documented using midrange scanner, and the smallest details are added in the highest resolution as close-up scans. The scanning devices are controlled using developed software equipped with advanced algorithms for point cloud processing. To verify the feasibility and effectiveness of multi-resolution 3D scanning in crime scene documentation, our platform was applied to document a murder scene simulated by the BPA experts from the Central Forensic Laboratory of the Police R&D, Warsaw, Poland. Applying the 3D scanning platform proved beneficial in the documentation of a crime scene combined with BPA. The multi-resolution 3D model enables virtual exploration of a scene in a three-dimensional environment, distance measurement, and gives a more realistic preservation of the evidences together with their surroundings. Moreover, high-resolution close-up scans aligned in a 3D model can be used to analyze bloodstains revealed at the crime scene. The result of BPA such as trajectories, and the area of origin are visualized and analyzed in an accurate model of a scene. At this stage, a simplified approach considering the trajectory of blood drop as a straight line is applied. Although the 3D scanning platform offers a new quality of crime scene documentation with BPA, some of the limitations of the technique are also mentioned.

  16. Influence of gait analysis on decision-making for lower extremity orthopaedic surgery: Baseline data from a randomized controlled trial.

    PubMed

    Wren, Tishya A L; Otsuka, Norman Y; Bowen, Richard E; Scaduto, Anthony A; Chan, Linda S; Sheng, Minya; Hara, Reiko; Kay, Robert M

    2011-07-01

    Previous studies examining the influence of gait analysis on surgical decision-making have been limited by the lack of a control group. The aim of this study was to use data from a randomized controlled trial to determine the effects of gait analysis on surgical decision-making in children with cerebral palsy (CP). 178 ambulatory children with CP (110 male; age 10.3±3.8 years) being considered for lower extremity orthopaedic surgery underwent gait analysis and were randomized into one of two groups: gait report group (N=90), where the orthopaedic surgeon received the gait analysis report, and control group (N=88), where the surgeon did not receive the gait report. Data regarding specific surgeries were recorded by the treating surgeon before gait analysis, by the gait laboratory surgeon after gait analysis, and after surgery. Agreement between the treatment done and the gait analysis recommendations was compared between groups using the 2-sided Fisher's Exact test. When a procedure was planned initially and also recommended by gait analysis, it was performed more often in the gait report group (91% vs. 70%, p<0.001). When the gait laboratory recommended against a planned procedure, the plan was changed more frequently in the gait report group (48% vs. 27%, p=0.009). When the gait laboratory recommended adding a procedure, it was added more frequently in the gait report group (12% vs. 7%, p=0.037). These results provide a stronger level of evidence demonstrating that gait analysis changes treatment decision-making and also reinforces decision-making when it agrees with the surgeon's original plan.

  17. Shod wear and foot alignment in clinical gait analysis.

    PubMed

    Louey, Melissa Gar Yee; Sangeux, Morgan

    2016-09-01

    Sagittal plane alignment of the foot presents challenges when the subject wears shoes during gait analysis. Typically, visual alignment is performed by positioning two markers, the heel and toe markers, aligned with the foot within the shoe. Alternatively, software alignment is possible when the sole of the shoe lies parallel to the ground, and the change in the shoe's sole thickness is measured and entered as a parameter. The aim of this technical note was to evaluate the accuracy of visual and software foot alignment during shod gait analysis. We calculated the static standing ankle angles of 8 participants (mean age: 8.7 years, SD: 2.9 years) wearing bilateral solid ankle foot orthoses (BSAFOs) with and without shoes using the visual and software alignment methods. All participants were able to stand with flat feet in both static trials and the ankle angles obtained in BSAFOs without shoes was considered the reference. We showed that the current implementation of software alignment introduces a bias towards more ankle dorsiflexion, mean=3°, SD=3.4°, p=0.006, and proposed an adjusted software alignment method. We found no statistical differences using visual alignment and adjusted software alignment between the shoe and shoeless conditions, p=0.19 for both. Visual alignment or adjusted software alignment are advised to represent foot alignment accurately.

  18. An empirical examination of detrended fluctuation analysis for gait data.

    PubMed

    Damouras, Sotirios; Chang, Matthew D; Sejdić, Ervin; Chau, Tom

    2010-03-01

    Stride interval series exhibit statistical persistence, and detrended fluctuation analysis (DFA) is a routinely employed technique for describing this behavior. However, the implementation of DFA to gait data varies considerably between studies. We empirically examine two practical aspects of DFA which significantly affect the analysis outcome: the box size range and the stride interval series length. We conduct an analysis of their effect using stride intervals from 16 able-bodied adults, for overground walking, treadmill walking while holding a handrail, and treadmill walking without using a handrail. Our goal is to provide general guidelines for these two choices, with the aim of standardizing the application of DFA and facilitating inter-study comparisons. Based on the results of our analysis, we propose the use of box sizes from 16 to N/9, where N is the number of stride intervals. Moreover, for differentiating between normal and pathological walking with reasonable accuracy, we recommend a minimum of 600 stride intervals.

  19. New technologies of 2-D and 3-D modeling for analysis and management of natural resources

    NASA Astrophysics Data System (ADS)

    Cheremisina, E. N.; Lyubimova, A. V.; Kirpicheva, E. Yu.

    2016-09-01

    For ensuring technological support of research and administrative activity in the sphere of environmental management a specialized modular program complex was developed. The special attention in developing a program complex is focused to creation of convenient and effective tools for creation and visualization 2d and 3D models providing the solution of tasks of the analysis and management of natural resources.

  20. Analysis of scalability of high-performance 3D image processing platform for virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Yoshida, Hiroyuki; Wu, Yin; Cai, Wenli

    2014-03-01

    One of the key challenges in three-dimensional (3D) medical imaging is to enable the fast turn-around time, which is often required for interactive or real-time response. This inevitably requires not only high computational power but also high memory bandwidth due to the massive amount of data that need to be processed. For this purpose, we previously developed a software platform for high-performance 3D medical image processing, called HPC 3D-MIP platform, which employs increasingly available and affordable commodity computing systems such as the multicore, cluster, and cloud computing systems. To achieve scalable high-performance computing, the platform employed size-adaptive, distributable block volumes as a core data structure for efficient parallelization of a wide range of 3D-MIP algorithms, supported task scheduling for efficient load distribution and balancing, and consisted of a layered parallel software libraries that allow image processing applications to share the common functionalities. We evaluated the performance of the HPC 3D-MIP platform by applying it to computationally intensive processes in virtual colonoscopy. Experimental results showed a 12-fold performance improvement on a workstation with 12-core CPUs over the original sequential implementation of the processes, indicating the efficiency of the platform. Analysis of performance scalability based on the Amdahl's law for symmetric multicore chips showed the potential of a high performance scalability of the HPC 3DMIP platform when a larger number of cores is available.

  1. Statistical analysis of cell migration in 3D using the anisotropic persistent random walk model.

    PubMed

    Wu, Pei-Hsun; Giri, Anjil; Wirtz, Denis

    2015-03-01

    Cell migration through 3D extracellular matrices (ECMs) is crucial to the normal development of tissues and organs and in disease processes, yet adequate analytical tools to characterize 3D migration are lacking. The motility of eukaryotic cells on 2D substrates in the absence of gradients has long been described using persistent random walks (PRWs). Recent work shows that 3D migration is anisotropic and features an exponential mean cell velocity distribution, rendering the PRW model invalid. Here we present a protocol for the analysis of 3D cell motility using the anisotropic PRW model. The software, which is implemented in MATLAB, enables statistical profiling of experimentally observed 2D and 3D cell trajectories, and it extracts the persistence and speed of cells along primary and nonprimary directions and an anisotropic index of migration. Basic computer skills and experience with MATLAB software are recommended for successful use of the protocol. This protocol is highly automated and fast, taking <30 min to analyze trajectory data per biological condition.

  2. A 3D contact analysis approach for the visualization of the electrical contact asperities

    PubMed Central

    Swingler, Jonathan

    2017-01-01

    The electrical contact is an important phenomenon that should be given into consideration to achieve better performance and long term reliability for the design of devices. Based upon this importance, the electrical contact interface has been visualized as a ‘‘3D Contact Map’’ and used in order to investigate the contact asperities. The contact asperities describe the structures above and below the contact spots (the contact spots define the 3D contact map) to the two conductors which make the contact system. The contact asperities require the discretization of the 3D microstructures of the contact system into voxels. A contact analysis approach has been developed and introduced in this paper which shows the way to the 3D visualization of the contact asperities of a given contact system. For the discretization of 3D microstructure of contact system into voxels, X-ray Computed Tomography (CT) method is used in order to collect the data of a 250 V, 16 A rated AC single pole rocker switch which is used as a contact system for investigation. PMID:28105383

  3. 3D city models for CAAD-supported analysis and design of urban areas

    NASA Astrophysics Data System (ADS)

    Sinning-Meister, M.; Gruen, A.; Dan, H.

    A joint research project was conducted at ETH Zurich to develop a user-friendly software environment for the representation, visual manipulation, analysis and design of urban areas. Three groups were involved in the project: (1) the 'Architecture and Planning' group defined the requirements and expectations for the system; (2) the 'Photogrammetry' group acquired and processed raster and 3D vector data to form a 3D model of the urban area; and (3) the 'CAAD' (Computer Aided Architectural Design) group embedded the data into AutoCAD and implemented database functionality. Results of the photogrammetry group are presented, including the implementation of a 'topology builder' which automatically fits roof planes to manually or semi-automatically measured roof points in order to create AutoCAD-compatible 3D building models. Digital orthoimages and derived products such as perspective views, and the geometric correction of house roofs in digital orthoimages also were generated for test sites in Switzerland.

  4. A Review of Failure Analysis Methods for Advanced 3D Microelectronic Packages

    NASA Astrophysics Data System (ADS)

    Li, Yan; Srinath, Purushotham Kaushik Muthur; Goyal, Deepak

    2016-01-01

    Advanced three dimensional (3D) packaging is a key enabler in driving form factor reduction, performance benefits, and package cost reduction, especially in the fast paced mobility and ultraportable consumer electronics segments. The high level of functional integration and the complex package architecture pose a significant challenge for conventional fault isolation (FI) and failure analysis (FA) methods. Innovative FI/FA tools and techniques are required to tackle the technical and throughput challenges. In this paper, the applications of FI and FA techniques such as Electro Optic Terahertz Pulse Reflectometry, 3D x-ray computed tomography, lock-in thermography, and novel physical sample preparation methods to 3D packages with package on package and stacked die with through silicon via configurations are reviewed, along with the key FI and FA challenges.

  5. Application of 3D X-ray CT data sets to finite element analysis

    SciTech Connect

    Bossart, P.L.; Martz, H.E.; Brand, H.R.; Hollerbach, K.

    1995-08-31

    Finite Element Modeling (FEM) is becoming more important as industry drives toward concurrent engineering. A fundamental hindrance to fully exploiting the power of FEM is the human effort required to acquire complex part geometry, particularly as-built geometry, as a FEM mesh. Many Quantitative Non Destructive Evaluation (QNDE) techniques that produce three-dimensional (3D) data sets provide a substantial reduction in the effort required to apply FEM to as-built parts. This paper describes progress at LLNL on the application of 3D X-ray computed tomography (CT) data sets to more rapidly produce high-quality FEM meshes of complex, as-built geometries. Issues related to the volume segmentation of the 3D CT data as well as the use of this segmented data to tailor generic hexahedral FEM meshes to part specific geometries are discussed. The application of these techniques to FEM analysis in the medical field is reported here.

  6. Numerical Investigation of 3D multichannel analysis of surface wave method

    NASA Astrophysics Data System (ADS)

    Wang, Limin; Xu, Yixian; Luo, Yinhe

    2015-08-01

    Multichannel analysis of surface wave (MASW) method is an efficient tool to obtain near-surface S-wave velocity, and it has gained popularity in engineering practice. Up to now, most examples of using the MASW technique are focused on 2D models or data from a 1D linear receiver spread. We propose a 3D MASW scheme. A finite-difference (FD) method is used to investigate the method using linear and fan-shaped receiver spreads. Results show that the 3D topography strongly affects propagation of Rayleigh waves. The energy concentration of dispersion image is distorted and bifurcated because of the influence of free-surface topography. These effects are reduced with the 3D MASW method. Lastly we investigate the relation between the array size and the resolution of dispersion measurement.

  7. 3D Printed Microfluidic Device with Integrated Biosensors for Online Analysis of Subcutaneous Human Microdialysate

    PubMed Central

    2015-01-01

    This work presents the design, fabrication, and characterization of a robust 3D printed microfluidic analysis system that integrates with FDA-approved clinical microdialysis probes for continuous monitoring of human tissue metabolite levels. The microfluidic device incorporates removable needle type integrated biosensors for glucose and lactate, which are optimized for high tissue concentrations, housed in novel 3D printed electrode holders. A soft compressible 3D printed elastomer at the base of the holder ensures a good seal with the microfluidic chip. Optimization of the channel size significantly improves the response time of the sensor. As a proof-of-concept study, our microfluidic device was coupled to lab-built wireless potentiostats and used to monitor real-time subcutaneous glucose and lactate levels in cyclists undergoing a training regime. PMID:26070023

  8. Application of FUN3D and CFL3D to the Third Workshop on CFD Uncertainty Analysis

    NASA Technical Reports Server (NTRS)

    Rumsey, C. L.; Thomas, J. L.

    2008-01-01

    Two Reynolds-averaged Navier-Stokes computer codes - one unstructured and one structured - are applied to two workshop cases (for the 3rd Workshop on CFD Uncertainty Analysis, held at Instituto Superior Tecnico, Lisbon, in October 2008) for the purpose of uncertainty analysis. The Spalart-Allmaras turbulence model is employed. The first case uses the method of manufactured solution and is intended as a verification case. In other words, the CFD solution is expected to approach the exact solution as the grid is refined. The second case is a validation case (comparison against experiment), for which modeling errors inherent in the turbulence model and errors/uncertainty in the experiment may prevent close agreement. The results from the two computer codes are also compared. This exercise verifies that the codes are consistent both with the exact manufactured solution and with each other. In terms of order property, both codes behave as expected for the manufactured solution. For the backward facing step, CFD uncertainty on the finest grid is computed and is generally very low for both codes (whose results are nearly identical). Agreement with experiment is good at some locations for particular variables, but there are also many areas where the CFD and experimental uncertainties do not overlap.

  9. Efficient curve-skeleton computation for the analysis of biomedical 3d images - biomed 2010.

    PubMed

    Brun, Francesco; Dreossi, Diego

    2010-01-01

    Advances in three dimensional (3D) biomedical imaging techniques, such as magnetic resonance (MR) and computed tomography (CT), make it easy to reconstruct high quality 3D models of portions of human body and other biological specimens. A major challenge lies in the quantitative analysis of the resulting models thus allowing a more comprehensive characterization of the object under investigation. An interesting approach is based on curve-skeleton (or medial axis) extraction, which gives basic information concerning the topology and the geometry. Curve-skeletons have been applied in the analysis of vascular networks and the diagnosis of tracheal stenoses as well as a 3D flight path in virtual endoscopy. However curve-skeleton computation is a crucial task. An effective skeletonization algorithm was introduced by N. Cornea in [1] but it lacks in computational performances. Thanks to the advances in imaging techniques the resolution of 3D images is increasing more and more, therefore there is the need for efficient algorithms in order to analyze significant Volumes of Interest (VOIs). In the present paper an improved skeletonization algorithm based on the idea proposed in [1] is presented. A computational comparison between the original and the proposed method is also reported. The obtained results show that the proposed method allows a significant computational improvement making more appealing the adoption of the skeleton representation in biomedical image analysis applications.

  10. Exploratory Climate Data Visualization and Analysis Using DV3D and UVCDAT

    NASA Technical Reports Server (NTRS)

    Maxwell, Thomas

    2012-01-01

    Earth system scientists are being inundated by an explosion of data generated by ever-increasing resolution in both global models and remote sensors. Advanced tools for accessing, analyzing, and visualizing very large and complex climate data are required to maintain rapid progress in Earth system research. To meet this need, NASA, in collaboration with the Ultra-scale Visualization Climate Data Analysis Tools (UVCOAT) consortium, is developing exploratory climate data analysis and visualization tools which provide data analysis capabilities for the Earth System Grid (ESG). This paper describes DV3D, a UV-COAT package that enables exploratory analysis of climate simulation and observation datasets. OV3D provides user-friendly interfaces for visualization and analysis of climate data at a level appropriate for scientists. It features workflow inte rfaces, interactive 40 data exploration, hyperwall and stereo visualization, automated provenance generation, and parallel task execution. DV30's integration with CDAT's climate data management system (COMS) and other climate data analysis tools provides a wide range of high performance climate data analysis operations. DV3D expands the scientists' toolbox by incorporating a suite of rich new exploratory visualization and analysis methods for addressing the complexity of climate datasets.

  11. PROP3D: A Program for 3D Euler Unsteady Aerodynamic and Aeroelastic (Flutter and Forced Response) Analysis of Propellers. Version 1.0

    NASA Technical Reports Server (NTRS)

    Srivastava, R.; Reddy, T. S. R.

    1996-01-01

    This guide describes the input data required, for steady or unsteady aerodynamic and aeroelastic analysis of propellers and the output files generated, in using PROP3D. The aerodynamic forces are obtained by solving three dimensional unsteady, compressible Euler equations. A normal mode structural analysis is used to obtain the aeroelastic equations, which are solved using either time domain or frequency domain solution method. Sample input and output files are included in this guide for steady aerodynamic analysis of single and counter-rotation propellers, and aeroelastic analysis of single-rotation propeller.

  12. Kinematic analysis of human walking gait using digital image processing.

    PubMed

    O'Malley, M; de Paor, D L

    1993-07-01

    A system using digital image processing techniques for kinematic analysis of human gait has been developed. The system is cheap, easy to use, automated and provides useful detailed quantitative information to the medical profession. Passive markers comprising black annuli on white card are placed on the anatomical landmarks of the subject. Digital images at the standard television rate of 25 per second are acquired of the subject walking past a white background. The images are obtained, stored and processed using standard commercially available hardware, i.e. video camera, video recorder, digital framestore and an IBM PC. Using a single-threshold grey level, all the images are thresholded to produce binary images. An automatic routine then uses a set of pattern recognition algorithms to locate accurately and consistently the markers in each image. The positions of the markers are analysed to determine to which anatomical landmark they correspond, and thus a stick diagram for each image is obtained. There is also a facility where the positions of the markers may be entered manually and errors corrected. The results may be presented in a variety of ways: stick diagram animation, sagittal displacement graphs, flexion diagrams and gait parameters.

  13. A 3-D aerodynamic method for the analysis of isolated horizontal-axis wind turbines

    SciTech Connect

    Ammara, I.; Masson, C.; Paraschivoiu, I.

    1997-12-31

    In most existing performance-analysis methods, wind turbines are considered isolated so that interference effects caused by other rotors or by the site topography are neglected. The main objective of this paper is to propose a practical 3-D method suitable for the study of these effects, in order to optimize the arrangement and the positioning of Horizontal-Axis Wind Turbines (HAWTs) in a wind farm. In the proposed methodology, the flow field around isolated HAWTs is predicted by solving the 3-D, time-averaged, steady-state, incompressible, Navier-Stokes equations in which the turbines are represented by distributions of momentum sources. The resulting governing equations are solved using a Control-Volume Finite Element Method (CVFEM). The fundamental aspects related to the development of a practical 3-D method are discussed in this paper, with an emphasis on some of the challenges that arose during its implementation. The current implementation is limited to the analysis of isolated HAWTs. Preliminary results have indicated that, the proposed 3-D method reaches the same level of accuracy, in terms of performance predictions, that the previously developed 2-D axisymmetric model and the well-known momentum-strip theory, while still using reasonable computers resources. It can be considered as a useful tool for the design of HAWTs. Its main advantages, however, are its intrinsic capacity to predict the details of the flow in the wake, and its capabilities of modelling arbitrary wind-turbine arrangements and including ground effects.

  14. Analysis of a 3-D system function measured for magnetic particle imaging.

    PubMed

    Rahmer, Jürgen; Weizenecker, Jürgen; Gleich, Bernhard; Borgert, Jörn

    2012-06-01

    Magnetic particle imaging (MPI) is a new tomographic imaging approach that can quantitatively map magnetic nanoparticle distributions in vivo. It is capable of volumetric real-time imaging at particle concentrations low enough to enable clinical applications. For image reconstruction in 3-D MPI, a system function (SF) is used, which describes the relation between the acquired MPI signal and the spatial origin of the signal. The SF depends on the instrumental configuration, the applied field sequence, and the magnetic particle characteristics. Its properties reflect the quality of the spatial encoding process. This work presents a detailed analysis of a measured SF to give experimental evidence that 3-D MPI encodes information using a set of 3-D spatial patterns or basis functions that is stored in the SF. This resembles filling 3-D k-space in magnetic resonance imaging, but is faster since all information is gathered simultaneously over a broad acquisition bandwidth. A frequency domain analysis shows that the finest structures that can be encoded with the presented SF are as small as 0.6 mm. SF simulations are performed to demonstrate that larger particle cores extend the set of basis functions towards higher resolution and that the experimentally observed spatial patterns require the existence of particles with core sizes of about 30 nm in the calibration sample. A simple formula is presented that qualitatively describes the basis functions to be expected at a certain frequency.

  15. Gait patterns comparison of children with Duchenne muscular dystrophy to those of control subjects considering the effect of gait velocity.

    PubMed

    Gaudreault, Nathaly; Gravel, Denis; Nadeau, Sylvie; Houde, Sylvie; Gagnon, Denis

    2010-07-01

    3D analysis of the gait of children with Duchenne muscular dystrophy (DMD) was the topic of only a few studies and none of these considered the effect of gait velocity on the gait parameters of children with DMD. Gait parameters of 11 children with DMD were compared to those of 14 control children while considering the effect of gait velocity using 3D biomechanical analysis. Kinematic and kinetic gait parameters were measured using an Optotrak motion analysis system and AMTI force plates embedded in the floor. The data profiles of children with DMD walking at natural gait velocity were compared to those of the control children who walked at both natural and slow gait velocities. When both groups walked at similar velocity, children with DMD had higher cadence and shorter step length. They demonstrated a lower hip extension moment as well as a minimal or absent knee extension moment. At the ankle, a dorsiflexion moment was absent at heel strike due to the anterior location of the center of pressure. The magnitude of the medio-lateral ground reaction force was higher in children with DMD. Despite this increase, the hip abductor moment was lower. Hip power generation was also observed at the mid-stance in DMD children. These results suggest that most of the modifications observed are strategies used by children with DMD to cope with possible muscle weakness in order to provide support, propulsion and balance of the body during gait.

  16. Multivoxel pattern analysis reveals 3D place information in the human hippocampus.

    PubMed

    Kim, Misun; Jeffery, Kate J; Maguire, Eleanor A

    2017-03-20

    The spatial world is three-dimensional (3D), and humans and other animals move both horizontally and vertically within it. Extant neuroscientific studies have typically investigated spatial navigation on a horizontal two-dimensional plane, leaving much unknown about how 3D spatial information is represented in the brain. Specifically, horizontal and vertical information may be encoded in the same or different neural structures with equal or unequal sensitivity. Here, we investigated these possibilities using functional MRI (fMRI) while participants were passively moved within a 3D lattice structure as if riding a rollercoaster. Multivoxel pattern analysis was used to test for the existence of information relating to where and in which direction participants were heading in this virtual environment. Behaviorally, participants had similarly accurate memory for vertical and horizontal locations, and the right anterior hippocampus expressed place information that was sensitive to changes along both horizontal and vertical axes. This is suggestive of isotropic 3D place encoding. By contrast, participants indicated their heading direction faster and more accurately when they were heading in a tilted-up or tilted-down direction. This direction information was expressed in the right retrosplenial cortex and posterior hippocampus, and was only sensitive to vertical pitch, which could reflect the importance of the vertical (gravity) axis as a reference frame. Overall, our findings extend previous knowledge of how we represent the spatial world and navigate within it, by taking into account the important third dimension.SIGNIFICANCE STATEMENTThe spatial world is three-dimensional (3D) -- we can move horizontally across surfaces, but also vertically, going up slopes or stairs. Little is known about how the brain supports representations of 3D space. A key question is whether or not horizontal and vertical information is equally well represented. Here we measured functional MRI

  17. Gait motion analysis in the unrestrained condition of trans-femoral amputee with a prosthetic limb.

    PubMed

    Hayashi, Yuichiro; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Uno, Ryuji; Matsuda, Yasushi; Tsuchiya, Youtaro; Inoue, Yoshio

    2012-01-01

    Trans-femoral amputees must regain moving pattern by refined rehabilitation program using ground reaction forces, joint angles and joint moments applied on a prosthetic limb. On the other hand, understanding those loads and kinematic variables is indispensable for gait analysis based on the biomechanical consideration of trans-femoral amputees. However, conventional prosthetic gait training systems cannot measure long continuous walking motions. In this paper, ground reaction forces and kinematic parameters applied on trans-femoral prosthesis are measured by the prosthetic gait motion analysis system using mobile force plate and attitude sensor for the unrestrained gait measurement. As a result of the experiments, the patterns of antero-posterior axis ground reaction forces and joint moments about the medio-lateral axis are remarkably different among the five activities. Finally, the effectiveness of the developed prosthetic gait training system to consider biomechanics and kinematics in trans-femoral prosthesis is validated.

  18. Statically vs dynamically balanced gait: Analysis of a robotic exoskeleton compared with a human.

    PubMed

    Barbareschi, Giulia; Richards, Rosie; Thornton, Matt; Carlson, Tom; Holloway, Catherine

    2015-01-01

    In recent years exoskeletons able to replicate human gait have begun to attract growing popularity for both assistive and rehabilitative purposes. Although wearable robots often need the use of external support in order to maintain stability, the REX exoskeleton by REX Bionics is able to self-balance through the whole cycle. However this statically balanced gait presents important differences with the dynamically balanced gait of human subjects. This paper will examine kinematic and kinetic differences between the gait analysis performed on a subject wearing the REX exoskeleton and human gait analysis data as presented in literature. We will also provide an insight on the impact that these differences can have for both rehabilitative and assistive applications.

  19. Quantification of Dynamic Morphological Drug Responses in 3D Organotypic Cell Cultures by Automated Image Analysis

    PubMed Central

    Härmä, Ville; Schukov, Hannu-Pekka; Happonen, Antti; Ahonen, Ilmari; Virtanen, Johannes; Siitari, Harri; Åkerfelt, Malin; Lötjönen, Jyrki; Nees, Matthias

    2014-01-01

    Glandular epithelial cells differentiate into complex multicellular or acinar structures, when embedded in three-dimensional (3D) extracellular matrix. The spectrum of different multicellular morphologies formed in 3D is a sensitive indicator for the differentiation potential of normal, non-transformed cells compared to different stages of malignant progression. In addition, single cells or cell aggregates may actively invade the matrix, utilizing epithelial, mesenchymal or mixed modes of motility. Dynamic phenotypic changes involved in 3D tumor cell invasion are sensitive to specific small-molecule inhibitors that target the actin cytoskeleton. We have used a panel of inhibitors to demonstrate the power of automated image analysis as a phenotypic or morphometric readout in cell-based assays. We introduce a streamlined stand-alone software solution that supports large-scale high-content screens, based on complex and organotypic cultures. AMIDA (Automated Morphometric Image Data Analysis) allows quantitative measurements of large numbers of images and structures, with a multitude of different spheroid shapes, sizes, and textures. AMIDA supports an automated workflow, and can be combined with quality control and statistical tools for data interpretation and visualization. We have used a representative panel of 12 prostate and breast cancer lines that display a broad spectrum of different spheroid morphologies and modes of invasion, challenged by a library of 19 direct or indirect modulators of the actin cytoskeleton which induce systematic changes in spheroid morphology and differentiation versus invasion. These results were independently validated by 2D proliferation, apoptosis and cell motility assays. We identified three drugs that primarily attenuated the invasion and formation of invasive processes in 3D, without affecting proliferation or apoptosis. Two of these compounds block Rac signalling, one affects cellular cAMP/cGMP accumulation. Our approach supports

  20. Automatic pole-like object modeling via 3D part-based analysis of point cloud

    NASA Astrophysics Data System (ADS)

    He, Liu; Yang, Haoxiang; Huang, Yuchun

    2016-10-01

    Pole-like objects, including trees, lampposts and traffic signs, are indispensable part of urban infrastructure. With the advance of vehicle-based laser scanning (VLS), massive point cloud of roadside urban areas becomes applied in 3D digital city modeling. Based on the property that different pole-like objects have various canopy parts and similar trunk parts, this paper proposed the 3D part-based shape analysis to robustly extract, identify and model the pole-like objects. The proposed method includes: 3D clustering and recognition of trunks, voxel growing and part-based 3D modeling. After preprocessing, the trunk center is identified as the point that has local density peak and the largest minimum inter-cluster distance. Starting from the trunk centers, the remaining points are iteratively clustered to the same centers of their nearest point with higher density. To eliminate the noisy points, cluster border is refined by trimming boundary outliers. Then, candidate trunks are extracted based on the clustering results in three orthogonal planes by shape analysis. Voxel growing obtains the completed pole-like objects regardless of overlaying. Finally, entire trunk, branch and crown part are analyzed to obtain seven feature parameters. These parameters are utilized to model three parts respectively and get signal part-assembled 3D model. The proposed method is tested using the VLS-based point cloud of Wuhan University, China. The point cloud includes many kinds of trees, lampposts and other pole-like posters under different occlusions and overlaying. Experimental results show that the proposed method can extract the exact attributes and model the roadside pole-like objects efficiently.

  1. 3D analysis of vortical structures in an abdominal aortic aneurysm by stereoscopic PIV

    NASA Astrophysics Data System (ADS)

    Deplano, Valérie; Guivier-Curien, Carine; Bertrand, Eric

    2016-11-01

    The present work presents an experimental in vitro three-dimensional analysis of the flow dynamics in an abdominal aortic aneurysm (AAA) through stereoscopic particle image velocimetry (SPIV) measurements. The experimental set-up mimics the pathophysiological context involving a shear thinning blood analogue fluid, compliant AAA and aorto-iliac bifurcation walls and controlled inlet and outlet flow rate and pressure waveforms as well as working fluid temperature. SPIV was carefully calibrated and conducted to assess the three velocity components in the AAA volume. For the first time in the literature, the 3D vortex ring genesis, propagation, and vanishing in the AAA bulge are experimentally described and quantified. In comparison with classical 2-component PIV measurements (2C PIV), the third component of the velocity vector was shown to be of importance in such a geometry, especially, during the deceleration phase of the flow rate. The 3D velocity magnitude reached up more than 20 % of the 2D one showing that 2C PIV are definitively not accurate enough to provide a complete description of flow behaviour in an AAA. In addition to potential clinical implications of a full 3D vortex ring description in AAA evolution, the 3D in vitro experimental quantification of the flow dynamics carried out in the present study offers an interesting tool for the validation of fluid-structure interaction numerical studies dealing with AAA.

  2. Integrated 3D-printed reactionware for chemical synthesis and analysis

    NASA Astrophysics Data System (ADS)

    Symes, Mark D.; Kitson, Philip J.; Yan, Jun; Richmond, Craig J.; Cooper, Geoffrey J. T.; Bowman, Richard W.; Vilbrandt, Turlif; Cronin, Leroy

    2012-05-01

    Three-dimensional (3D) printing has the potential to transform science and technology by creating bespoke, low-cost appliances that previously required dedicated facilities to make. An attractive, but unexplored, application is to use a 3D printer to initiate chemical reactions by printing the reagents directly into a 3D reactionware matrix, and so put reactionware design, construction and operation under digital control. Here, using a low-cost 3D printer and open-source design software we produced reactionware for organic and inorganic synthesis, which included printed-in catalysts and other architectures with printed-in components for electrochemical and spectroscopic analysis. This enabled reactions to be monitored in situ so that different reactionware architectures could be screened for their efficacy for a given process, with a digital feedback mechanism for device optimization. Furthermore, solely by modifying reactionware architecture, reaction outcomes can be altered. Taken together, this approach constitutes a relatively cheap, automated and reconfigurable chemical discovery platform that makes techniques from chemical engineering accessible to typical synthetic laboratories.

  3. Discrimination of Rhizoma Gastrodiae (Tianma) using 3D synchronous fluorescence spectroscopy coupled with principal component analysis

    NASA Astrophysics Data System (ADS)

    Fan, Qimeng; Chen, Chaoyin; Huang, Zaiqiang; Zhang, Chunmei; Liang, Pengjuan; Zhao, Shenglan

    2015-02-01

    Rhizoma Gastrodiae (Tianma) of different variants and different geographical origins has vital difference in quality and physiological efficacy. This paper focused on the classification and identification of Tianma of six types (two variants from three different geographical origins) using three dimensional synchronous fluorescence spectroscopy (3D-SFS) coupled with principal component analysis (PCA). 3D-SF spectra of aqueous extracts, which were obtained from Tianma of the six types, were measured by a LS-50B luminescence spectrofluorometer. The experimental results showed that the characteristic fluorescent spectral regions of the 3D-SF spectra were similar, while the intensities of characteristic regions are different significantly. Coupled these differences in peak intensities with PCA, Tianma of six types could be discriminated successfully. In conclusion, 3D-SFS coupled with PCA, which has such advantages as effective, specific, rapid, non-polluting, has an edge for discrimination of the similar Chinese herbal medicine. And the proposed methodology is a useful tool to classify and identify Tianma of different variants and different geographical origins.

  4. Symmetry Analysis of Gait between Left and Right Limb Using Cross-Fuzzy Entropy

    PubMed Central

    Ye, Qiang; Gao, Qingwei; Lu, Yixiang; Zhang, Dexiang

    2016-01-01

    The purpose of this paper is the investigation of gait symmetry problem by using cross-fuzzy entropy (C-FuzzyEn), which is a recently proposed cross entropy that has many merits as compared to the frequently used cross sample entropy (C-SampleEn). First, we used several simulation signals to test its performance regarding the relative consistency and dependence on data length. Second, the gait time series of the left and right stride interval were used to calculate the C-FuzzyEn values for gait symmetry analysis. Besides the statistical analysis, we also realized a support vector machine (SVM) classifier to perform the classification of normal and abnormal gaits. The gait dataset consists of 15 patients with Parkinson's disease (PD) and 16 control (CO) subjects. The results show that the C-FuzzyEn values of the PD patients' gait are significantly higher than that of the CO subjects with a p value of less than 10−5, and the best classification performance evaluated by a leave-one-out (LOO) cross-validation method is an accuracy of 96.77%. Such encouraging results imply that the C-FuzzyEn-based gait symmetry measure appears as a suitable tool for analyzing abnormal gaits. PMID:27034706

  5. Characteristics Analysis on Various Kinds of Hybrid Stepping Motors Using 3D Finite Element Method

    NASA Astrophysics Data System (ADS)

    Enomoto, Yuji; Maki, Kohji; Miyata, Kenji; Oonishi, Kazuo; Sakamoto, Masafumi; Abukawa, Toshimi

    We have presented a powerful scheme of investigating hybrid stepping motor characteristics by using 3D finite element method. A linear magnetic field analysis is effectively applicable to predict relative performance of several motors in an extremely short computing time. The waveforms of cogging torque by linear and nonlinear analysis resemble each other, while the wave amplitude in the linear analysis is about 2 times larger than one in the nonlinear analysis in the presented example. The overestimation factor of cogging torque is approximately constant for the same material composition.

  6. Error Analysis of Terrestrial Laser Scanning Data by Means of Spherical Statistics and 3D Graphs

    PubMed Central

    Cuartero, Aurora; Armesto, Julia; Rodríguez, Pablo G.; Arias, Pedro

    2010-01-01

    This paper presents a complete analysis of the positional errors of terrestrial laser scanning (TLS) data based on spherical statistics and 3D graphs. Spherical statistics are preferred because of the 3D vectorial nature of the spatial error. Error vectors have three metric elements (one module and two angles) that were analyzed by spherical statistics. A study case has been presented and discussed in detail. Errors were calculating using 53 check points (CP) and CP coordinates were measured by a digitizer with submillimetre accuracy. The positional accuracy was analyzed by both the conventional method (modular errors analysis) and the proposed method (angular errors analysis) by 3D graphics and numerical spherical statistics. Two packages in R programming language were performed to obtain graphics automatically. The results indicated that the proposed method is advantageous as it offers a more complete analysis of the positional accuracy, such as angular error component, uniformity of the vector distribution, error isotropy, and error, in addition the modular error component by linear statistics. PMID:22163461

  7. 3D cephalometric analysis obtained from computed tomography. Review of the literature

    PubMed Central

    Rossini, Giulia; Cavallini, Costanza; Cassetta, Michele; Barbato, Ersilia

    2012-01-01

    Summary Introduction The aim of this systematic review is to estimate accuracy and reproducibility of craniometric measurements and reliability of landmarks identified with computed tomography (CT) techniques in 3D cephalometric analysis. Methods Computerized and manual searches were conducted up to 2011 for studies that addressed these objectives. The selection criteria were: (1) the use of human specimen; (2) the comparison between 2D and 3D cephalometric analysis; (3) the assessment of accuracy, reproducibility of measurements and reliability of landmark identification with CT images compared with two-dimensional conventional radiographs. The Cochrane Handbook for Systematic Reviews of Interventions was used as the guideline for this article. Results Twenty-seven articles met the inclusion criteria. Most of them demonstrated high measurements accuracy and reproducibility, and landmarks reliability, but their cephalometric analysis methodology varied widely. Conclusion These differencies among the studies in making measurements don’t permit a direct comparison between them. The future developments in the knowledge of these techniques should provide a standardized method to conduct the 3D CT cephalometric analysis. PMID:22545187

  8. Performance analysis of 3-D shape measurement algorithm with a short baseline projector-camera system.

    PubMed

    Liu, Jianyang; Li, Youfu

    A number of works for 3-D shape measurement based on structured light have been well-studied in the last decades. A common way to model the system is to use the binocular stereovision-like model. In this model, the projector is treated as a camera, thus making a projector-camera-based system unified with a well-established traditional binocular stereovision system. After calibrating the projector and camera, a 3-D shape information is obtained by conventional triangulation. However, in such a stereovision-like system, the short baseline problem exists and limits the measurement accuracy. Hence, in this work, we present a new projecting-imaging model based on fringe projection profilometry (FPP). In this model, we first derive a rigorous mathematical relationship that exists between the height of an object's surface, the phase difference distribution map, and the parameters of the setup. Based on this model, we then study the problem of how the uncertainty of relevant parameters, particularly the baseline's length, affects the 3-D shape measurement accuracy using our proposed model. We provide an extensive uncertainty analysis on the proposed model through partial derivative analysis, relative error analysis, and sensitivity analysis. Moreover, the Monte Carlo simulation experiment is also conducted which shows that the measurement performance of the projector-camera system has a short baseline.

  9. On 3-D inelastic analysis methods for hot section components. Volume 1: Special finite element models

    NASA Technical Reports Server (NTRS)

    Nakazawa, S.

    1988-01-01

    This annual status report presents the results of work performed during the fourth year of the 3-D Inelastic Analysis Methods for Hot Section Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of new computer codes permitting more accurate and efficient 3-D analysis of selected hot section components, i.e., combustor liners, turbine blades and turbine vanes. The computer codes embody a progression of math models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components. Volume 1 of this report discusses the special finite element models developed during the fourth year of the contract.

  10. Shape analysis of corpus callosum in phenylketonuria using a new 3D correspondence algorithm

    NASA Astrophysics Data System (ADS)

    He, Qing; Christ, Shawn E.; Karsch, Kevin; Peck, Dawn; Duan, Ye

    2010-03-01

    Statistical shape analysis of brain structures has gained increasing interest from neuroimaging community because it can precisely locate shape differences between healthy and pathological structures. The most difficult and crucial problem is establishing shape correspondence among individual 3D shapes. This paper proposes a new algorithm for 3D shape correspondence. A set of landmarks are sampled on a template shape, and initial correspondence is established between the template and the target shape based on the similarity of locations and normal directions. The landmarks on the target are then refined by iterative thin plate spline. The algorithm is simple and fast, and no spherical mapping is needed. We apply our method to the statistical shape analysis of the corpus callosum (CC) in phenylketonuria (PKU), and significant local shape differences between the patients and the controls are found in the most anterior and posterior aspects of the corpus callosum.

  11. A Method for Sectioning and Immunohistochemical Analysis of Stem Cell-Derived 3-D Organoids.

    PubMed

    Wiley, Luke A; Beebe, David C; Mullins, Robert F; Stone, Edwin M; Tucker, Budd A

    2016-05-12

    This unit describes a protocol for embedding, sectioning, and immunocytochemical analysis of pluripotent stem cell-derived 3-D organoids. Specifically, we describe a method to embed iPSC-derived retinal cups in low-melt agarose, acquire thick sections using a vibratome tissue slicer, and perform immunohistochemical analysis. This method includes an approach for antibody labeling that minimizes the amount of antibody needed for individual experiments and that utilizes large-volume washing to increase the signal-to-noise ratio, allowing for clean, high-resolution imaging of developing cell types. The universal methods described can be employed regardless of the type of pluripotent stem cell used and 3-D organoid generated. © 2016 by John Wiley & Sons, Inc.

  12. Gait analysis using floor markers and inertial sensors.

    PubMed

    Do, Tri Nhut; Suh, Young Soo

    2012-01-01

    In this paper, a gait analysis system which estimates step length and foot angles is proposed. A measurement unit, which consists of a camera and inertial sensors, is installed on a shoe. When the foot touches the floor, markers are recognized by the camera to obtain the current position and attitude. A simple planar marker with 4,096 different codes is used. These markers printed on paper are placed on the floor. When the foot is moving off the floor, the position and attitude are estimated using an inertial navigation algorithm. For accurate estimation, a smoother is proposed, where vision information and inertial sensor data are combined. Through experiments, it is shown that the proposed system can both track foot motion and estimate step length.

  13. Analysis and 3D visualization of structures of animal brains obtained from histological sections

    NASA Astrophysics Data System (ADS)

    Forero-Vargas, Manuel G.; Fuentes, Veronica; Lopez, D.; Moscoso, A.; Merchan, Miguel A.

    2002-11-01

    This paper presents a new application for the analysis of histological sections and their 3D visualization. The process is performed in few steps. First, a manual process is necessary to determine the regions of interest, including image digitalization, drawing of borders and alignment between all images. Then, a reconstruction process is made. After sampling the contour, the structure of interest is displayed. The application is experimentally validated and some results on histological sections of a rodent's brain (hamster and rat) are shown.

  14. Analysis of 3D Subharmonic Ultrasound Signals from Patients with Known Breast Masses for Lesion Differentiation

    DTIC Science & Technology

    2012-10-01

    AD_____________ Award Number: W81XWH-11-1-0630 TITLE: Analysis of 3D Subharmonic Ultrasound Signals from Patients with Known Breast... Ultrasound Signals from Patients with Known Breast Masses for Lesion Differentiation 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-11-1-0630 5c...videos were obtained as part of a larger NIH funded clinical trial. The research 15. SUBJECT TERMS Breast Cancer, Ultrasound Imaging, Ultrasound

  15. Importance of a 3D forward modeling tool for surface wave analysis methods

    NASA Astrophysics Data System (ADS)

    Pageot, Damien; Le Feuvre, Mathieu; Donatienne, Leparoux; Philippe, Côte; Yann, Capdeville

    2016-04-01

    Since a few years, seismic surface waves analysis methods (SWM) have been widely developed and tested in the context of subsurface characterization and have demonstrated their effectiveness for sounding and monitoring purposes, e.g., high-resolution tomography of the principal geological units of California or real time monitoring of the Piton de la Fournaise volcano. Historically, these methods are mostly developed under the assumption of semi-infinite 1D layered medium without topography. The forward modeling is generally based on Thomson-Haskell matrix based modeling algorithm and the inversion is driven by Monte-Carlo sampling. Given their efficiency, SWM have been transfered to several scale of which civil engineering structures in order to, e.g., determine the so-called V s30 parameter or assess other critical constructional parameters in pavement engineering. However, at this scale, many structures may often exhibit 3D surface variations which drastically limit the efficiency of SWM application. Indeed, even in the case of an homogeneous structure, 3D geometry can bias the dispersion diagram of Rayleigh waves up to obtain discontinuous phase velocity curves which drastically impact the 1D mean velocity model obtained from dispersion inversion. Taking advantages of high-performance computing center accessibility and wave propagation modeling algorithm development, it is now possible to consider the use of a 3D elastic forward modeling algorithm instead of Thomson-Haskell method in the SWM inversion process. We use a parallelized 3D elastic modeling code based on the spectral element method which allows to obtain accurate synthetic data with very low numerical dispersion and a reasonable numerical cost. In this study, we choose dike embankments as an illustrative example. We first show that their longitudinal geometry may have a significant effect on dispersion diagrams of Rayleigh waves. Then, we demonstrate the necessity of 3D elastic modeling as a forward

  16. Application of 3D Spatio-Temporal Data Modeling, Management, and Analysis in DB4GEO

    NASA Astrophysics Data System (ADS)

    Kuper, P. V.; Breunig, M.; Al-Doori, M.; Thomsen, A.

    2016-10-01

    Many of todaýs world wide challenges such as climate change, water supply and transport systems in cities or movements of crowds need spatio-temporal data to be examined in detail. Thus the number of examinations in 3D space dealing with geospatial objects moving in space and time or even changing their shapes in time will rapidly increase in the future. Prominent spatio-temporal applications are subsurface reservoir modeling, water supply after seawater desalination and the development of transport systems in mega cities. All of these applications generate large spatio-temporal data sets. However, the modeling, management and analysis of 3D geo-objects with changing shape and attributes in time still is a challenge for geospatial database architectures. In this article we describe the application of concepts for the modeling, management and analysis of 2.5D and 3D spatial plus 1D temporal objects implemented in DB4GeO, our service-oriented geospatial database architecture. An example application with spatio-temporal data of a landfill, near the city of Osnabrück in Germany demonstrates the usage of the concepts. Finally, an outlook on our future research focusing on new applications with big data analysis in three spatial plus one temporal dimension in the United Arab Emirates, especially the Dubai area, is given.

  17. Integrating Data Clustering and Visualization for the Analysis of 3D Gene Expression Data

    SciTech Connect

    Data Analysis and Visualization and the Department of Computer Science, University of California, Davis, One Shields Avenue, Davis CA 95616, USA,; nternational Research Training Group ``Visualization of Large and Unstructured Data Sets,'' University of Kaiserslautern, Germany; Computational Research Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, CA 94720, USA; Genomics Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley CA 94720, USA; Life Sciences Division, Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley CA 94720, USA,; Computer Science Division,University of California, Berkeley, CA, USA,; Computer Science Department, University of California, Irvine, CA, USA,; All authors are with the Berkeley Drosophila Transcription Network Project, Lawrence Berkeley National Laboratory,; Rubel, Oliver; Weber, Gunther H.; Huang, Min-Yu; Bethel, E. Wes; Biggin, Mark D.; Fowlkes, Charless C.; Hendriks, Cris L. Luengo; Keranen, Soile V. E.; Eisen, Michael B.; Knowles, David W.; Malik, Jitendra; Hagen, Hans; Hamann, Bernd

    2008-05-12

    The recent development of methods for extracting precise measurements of spatial gene expression patterns from three-dimensional (3D) image data opens the way for new analyses of the complex gene regulatory networks controlling animal development. We present an integrated visualization and analysis framework that supports user-guided data clustering to aid exploration of these new complex datasets. The interplay of data visualization and clustering-based data classification leads to improved visualization and enables a more detailed analysis than previously possible. We discuss (i) integration of data clustering and visualization into one framework; (ii) application of data clustering to 3D gene expression data; (iii) evaluation of the number of clusters k in the context of 3D gene expression clustering; and (iv) improvement of overall analysis quality via dedicated post-processing of clustering results based on visualization. We discuss the use of this framework to objectively define spatial pattern boundaries and temporal profiles of genes and to analyze how mRNA patterns are controlled by their regulatory transcription factors.

  18. Inertial sensor-based two feet motion tracking for gait analysis.

    PubMed

    Hung, Tran Nhat; Suh, Young Soo

    2013-04-29

    Two feet motion is estimated for gait analysis. An inertial sensor is attached on each shoe and an inertial navigation algorithm is used to estimate the movement of both feet. To correct inter-shoe position error, a camera is installed on the right shoe and infrared LEDs are installed on the left shoe. The proposed system gives key gait analysis parameters such as step length, stride length, foot angle and walking speed. Also it gives three dimensional trajectories of two feet for gait analysis.

  19. The three-dimensional elemental distribution based on the surface topography by confocal 3D-XRF analysis

    NASA Astrophysics Data System (ADS)

    Yi, Longtao; Qin, Min; Wang, Kai; Lin, Xue; Peng, Shiqi; Sun, Tianxi; Liu, Zhiguo

    2016-09-01

    Confocal three-dimensional micro-X-ray fluorescence (3D-XRF) is a good surface analysis technology widely used to analyse elements and elemental distributions. However, it has rarely been applied to analyse surface topography and 3D elemental mapping in surface morphology. In this study, a surface adaptive algorithm using the progressive approximation method was designed to obtain surface topography. A series of 3D elemental mapping analyses in surface morphology were performed in laboratories to analyse painted pottery fragments from the Majiayao Culture (3300-2900 BC). To the best of our knowledge, for the first time, sample surface topography and 3D elemental mapping were simultaneously obtained. Besides, component and depth analyses were also performed using synchrotron radiation confocal 3D-XRF and tabletop confocal 3D-XRF, respectively. The depth profiles showed that the sample has a layered structure. The 3D elemental mapping showed that the red pigment, black pigment, and pottery coat contain a large amount of Fe, Mn, and Ca, respectively. From the 3D elemental mapping analyses at different depths, a 3D rendering was obtained, clearly showing the 3D distributions of the red pigment, black pigment, and pottery coat. Compared with conventional 3D scanning, this method is time-efficient for analysing 3D elemental distributions and hence especially suitable for samples with non-flat surfaces.

  20. When human walking becomes random walking: fractal analysis and modeling of gait rhythm fluctuations.

    PubMed

    Hausdorff, J M; Ashkenazy, Y; Peng, C K; Ivanov, P C; Stanley, H E; Goldberger, A L

    2001-12-15

    We present a random walk, fractal analysis of the stride-to-stride fluctuations in the human gait rhythm. The gait of healthy young adults is scale-free with long-range correlations extending over hundreds of strides. This fractal scaling changes characteristically with maturation in children and older adults and becomes almost completely uncorrelated with certain neurologic diseases. Stochastic modeling of the gait rhythm dynamics, based on transitions between different "neural centers", reproduces distinctive statistical properties of the gait pattern. By tuning one model parameter, the hopping (transition) range, the model can describe alterations in gait dynamics from childhood to adulthood including a decrease in the correlation and volatility exponents with maturation.

  1. When human walking becomes random walking: fractal analysis and modeling of gait rhythm fluctuations

    NASA Astrophysics Data System (ADS)

    Hausdorff, Jeffrey M.; Ashkenazy, Yosef; Peng, Chang-K.; Ivanov, Plamen Ch.; Stanley, H. Eugene; Goldberger, Ary L.

    2001-12-01

    We present a random walk, fractal analysis of the stride-to-stride fluctuations in the human gait rhythm. The gait of healthy young adults is scale-free with long-range correlations extending over hundreds of strides. This fractal scaling changes characteristically with maturation in children and older adults and becomes almost completely uncorrelated with certain neurologic diseases. Stochastic modeling of the gait rhythm dynamics, based on transitions between different “neural centers”, reproduces distinctive statistical properties of the gait pattern. By tuning one model parameter, the hopping (transition) range, the model can describe alterations in gait dynamics from childhood to adulthood - including a decrease in the correlation and volatility exponents with maturation.

  2. A Grassmann graph embedding framework for gait analysis

    NASA Astrophysics Data System (ADS)

    Connie, Tee; Goh, Michael Kah Ong; Teoh, Andrew Beng Jin

    2014-12-01

    Gait recognition is important in a wide range of monitoring and surveillance applications. Gait information has often been used as evidence when other biometrics is indiscernible in the surveillance footage. Building on recent advances of the subspace-based approaches, we consider the problem of gait recognition on the Grassmann manifold. We show that by embedding the manifold into reproducing kernel Hilbert space and applying the mechanics of graph embedding on such manifold, significant performance improvement can be obtained. In this work, the gait recognition problem is studied in a unified way applicable for both supervised and unsupervised configurations. Sparse representation is further incorporated in the learning mechanism to adaptively harness the local structure of the data. Experiments demonstrate that the proposed method can tolerate variations in appearance for gait identification effectively.

  3. Performance analysis of high quality parallel preconditioners applied to 3D finite element structural analysis

    SciTech Connect

    Kolotilina, L.; Nikishin, A.; Yeremin, A.

    1994-12-31

    The solution of large systems of linear equations is a crucial bottleneck when performing 3D finite element analysis of structures. Also, in many cases the reliability and robustness of iterative solution strategies, and their efficiency when exploiting hardware resources, fully determine the scope of industrial applications which can be solved on a particular computer platform. This is especially true for modern vector/parallel supercomputers with large vector length and for modern massively parallel supercomputers. Preconditioned iterative methods have been successfully applied to industrial class finite element analysis of structures. The construction and application of high quality preconditioners constitutes a high percentage of the total solution time. Parallel implementation of high quality preconditioners on such architectures is a formidable challenge. Two common types of existing preconditioners are the implicit preconditioners and the explicit preconditioners. The implicit preconditioners (e.g. incomplete factorizations of several types) are generally high quality but require solution of lower and upper triangular systems of equations per iteration which are difficult to parallelize without deteriorating the convergence rate. The explicit type of preconditionings (e.g. polynomial preconditioners or Jacobi-like preconditioners) require sparse matrix-vector multiplications and can be parallelized but their preconditioning qualities are less than desirable. The authors present results of numerical experiments with Factorized Sparse Approximate Inverses (FSAI) for symmetric positive definite linear systems. These are high quality preconditioners that possess a large resource of parallelism by construction without increasing the serial complexity.

  4. Microstructure analysis of the secondary pulmonary lobules by 3D synchrotron radiation CT

    NASA Astrophysics Data System (ADS)

    Fukuoka, Y.; Kawata, Y.; Niki, N.; Umetani, K.; Nakano, Y.; Ohmatsu, H.; Moriyama, N.; Itoh, H.

    2014-03-01

    Recognition of abnormalities related to the lobular anatomy has become increasingly important in the diagnosis and differential diagnosis of lung abnormalities at clinical routines of CT examinations. This paper aims a 3-D microstructural analysis of the pulmonary acinus with isotropic spatial resolution in the range of several micrometers by using micro CT. Previously, we demonstrated the ability of synchrotron radiation micro CT (SRμCT) using offset scan mode in microstructural analysis of the whole part of the secondary pulmonary lobule. In this paper, we present a semiautomatic method to segment the acinar and subacinar airspaces from the secondary pulmonary lobule and to track small vessels running inside alveolar walls in human acinus imaged by the SRμCT. The method beains with and segmentation of the tissues such as pleural surface, interlobular septa, alveola wall, or vessel using a threshold technique and 3-D connected component analysis. 3-D air space are then conustructed separated by tissues and represented branching patterns of airways and airspaces distal to the terminal bronchiole. A graph-partitioning approach isolated acini whose stems are interactively defined as the terminal bronchiole in the secondary pulmonary lobule. Finally, we performed vessel tracking using a non-linear sate space which captures both smoothness of the trajectories and intensity coherence along vessel orientations. Results demonstrate that the proposed method can extract several acinar airspaces from the 3-D SRμCT image of secondary pulmonary lobule and that the extracted acinar airspace enable an accurate quantitative description of the anatomy of the human acinus for interpretation of the basic unit of pulmonary structure and function.

  5. Simultaneous Aerodynamic Analysis and Design Optimization (SAADO) for a 3-D Flexible Wing

    NASA Technical Reports Server (NTRS)

    Gumbert, Clyde R.; Hou, Gene J.-W.

    2001-01-01

    The formulation and implementation of an optimization method called Simultaneous Aerodynamic Analysis and Design Optimization (SAADO) are extended from single discipline analysis (aerodynamics only) to multidisciplinary analysis - in this case, static aero-structural analysis - and applied to a simple 3-D wing problem. The method aims to reduce the computational expense incurred in performing shape optimization using state-of-the-art Computational Fluid Dynamics (CFD) flow analysis, Finite Element Method (FEM) structural analysis and sensitivity analysis tools. Results for this small problem show that the method reaches the same local optimum as conventional optimization. However, unlike its application to the win,, (single discipline analysis), the method. as I implemented here, may not show significant reduction in the computational cost. Similar reductions were seen in the two-design-variable (DV) problem results but not in the 8-DV results given here.

  6. [Gait disorders in Parkinson disease. Clinical description, analysis of posture, initiation of stabilized gait].

    PubMed

    Kemoun, G; Defebvre, L

    2001-03-10

    A WELL INFORMED DESCRIPTION: The parkinsonian posture is generally described as a stooped one. At the beginning of the disease, the gait troubles remain moderate; gradually the gait is composed of small steps without a wide base; the patient tends to run after his centre of gravity by accelerating the step (festination phenomenon). Difficulties occurs for starting up (delay of gait initiation), for about-turn or for clearing obstacles. Kinetic jammings and standing around (freezing) can last several seconds and be responsible for falls. POSTURAL INSTABILITY, A MAJOR SYMPTOM IN PARKINSON'S DISEASE: This symptom is little improved by therapies and is responsible for serious disability. Postural instability induces a disequilibrium and is partially due to a simultaneous antagonist muscles contraction and to the impossibility of modifying postural responses to changing support conditions. The passive viscoelastic properties of muscles and tendons constitute a first line of defence against the disequilibrium and contribute to postural stability in the case of medium disturbances. Automatic and voluntary postural responses which come into play in the case of major disturbances can also be impaired (delay or defect of the responses). GAIT INITIATION FAILURE ARE FREQUENT: They result from an increase of the postural phase and a decrease of the propulsion forces, depending on a deficit of the postural anticipation mechanisms and also the sequential organization and the integration of two different motor programs, postural and locomotor. They can be controlled partially with sensory stimuli, notably visual inputs. DATA CONCERNING STABILIZED WALKING AND ITS PATHOPHYSIOLOGY REMAINS TO BE CLARIFIED: Spatial and temporal parameters are impaired: speed, step length and swing phase are reduced, while cadence increases to compensate these troubles. These modifications are the consequence of an incapacity to produce internal marks to generate regular steps. When the parkinsonian

  7. A Generalized Approach to the Modeling and Analysis of 3D Surface Morphology in Organisms

    PubMed Central

    Pappas, Janice L.; Miller, Daniel J.

    2013-01-01

    The surface geometry of an organism represents the boundary of its three-dimensional (3D) form and can be used as a proxy for the phenotype. A mathematical approach is presented that describes surface morphology using parametric 3D equations with variables expressed as x, y, z in terms of parameters u, v. Partial differentiation of variables with respect to parameters yields elements of the Jacobian representing tangent lines and planes of every point on the surface. Jacobian elements provide a compact size-free summary of the entire surface, and can be used as variables in principal components analysis to produce a morphospace. Mollusk and echinoid models are generated to demonstrate that whole organisms can be represented in a common morphospace, regardless of differences in size, geometry, and taxonomic affinity. Models can be used to simulate theoretical forms, novel morphologies, and patterns of phenotypic variation, and can also be empirically-based by designing them with reference to actual forms using reverse engineering principles. Although this study uses the Jacobian to summarize models, they can also be analyzed with 3D methods such as eigensurface, spherical harmonics, wavelet analysis, and geometric morphometrics. This general approach should prove useful for exploring broad questions regarding morphological evolution and variation. PMID:24204866

  8. Analysis of uncertainty and repeatability of a low-cost 3D laser scanner.

    PubMed

    Polo, María-Eugenia; Felicísimo, Angel M

    2012-01-01

    Portable 3D laser scanners are a valuable tool for compiling elaborate digital collections of archaeological objects and analysing the shapes and dimensions of pieces. Although low-cost desktop 3D laser scanners have powerful capacities, it is important to know their limitations. This paper performs an analysis of the uncertainty and repeatability of the NextEngine™ portable low-cost 3D laser scanner by scanning an object 20 times in two different resolution modes-Macro and Wide. Some dimensions of the object were measured using a digital calliper, and these results were used as the "true" or control data. In comparing the true and the scanned data, we verified that the mean uncertainty in the Macro Mode is approximately half that of the Wide Mode, at ± 0.81 mm and ± 1.66 mm, respectively. These experimental results are significantly higher than the accuracy specifications provided by the manufacturer. An analysis of repeatability shows that the successive replicates do not match in the same position. The results are better in Macro Mode than in Wide Mode; it is observed that the repeatability factor is slightly larger than the corresponding mode accuracy, with ± 0.84 vs. ± 0.81 mm in Macro Mode and ± 1.82 vs. ± 1.66 mm in Wide Mode. We suggest several improvements, such as adding an external reference scale or providing a calibrated object to allow for a self-calibration operation of the scanner.

  9. Quantitative analysis of the central-chest lymph nodes based on 3D MDCT image data

    NASA Astrophysics Data System (ADS)

    Lu, Kongkuo; Bascom, Rebecca; Mahraj, Rickhesvar P. M.; Higgins, William E.

    2009-02-01

    Lung cancer is the leading cause of cancer death in the United States. In lung-cancer staging, central-chest lymph nodes and associated nodal stations, as observed in three-dimensional (3D) multidetector CT (MDCT) scans, play a vital role. However, little work has been done in relation to lymph nodes, based on MDCT data, due to the complicated phenomena that give rise to them. Using our custom computer-based system for 3D MDCT-based pulmonary lymph-node analysis, we conduct a detailed study of lymph nodes as depicted in 3D MDCT scans. In this work, the Mountain lymph-node stations are automatically defined by the system. These defined stations, in conjunction with our system's image processing and visualization tools, facilitate lymph-node detection, classification, and segmentation. An expert pulmonologist, chest radiologist, and trained technician verified the accuracy of the automatically defined stations and indicated observable lymph nodes. Next, using semi-automatic tools in our system, we defined all indicated nodes. Finally, we performed a global quantitative analysis of the characteristics of the observed nodes and stations. This study drew upon a database of 32 human MDCT chest scans. 320 Mountain-based stations (10 per scan) and 852 pulmonary lymph nodes were defined overall from this database. Based on the numerical results, over 90% of the automatically defined stations were deemed accurate. This paper also presents a detailed summary of central-chest lymph-node characteristics for the first time.

  10. Scientific rotoscoping: a morphology-based method of 3-D motion analysis and visualization.

    PubMed

    Gatesy, Stephen M; Baier, David B; Jenkins, Farish A; Dial, Kenneth P

    2010-06-01

    Three-dimensional skeletal movement is often impossible to accurately quantify from external markers. X-ray imaging more directly visualizes moving bones, but extracting 3-D kinematic data is notoriously difficult from a single perspective. Stereophotogrammetry is extremely powerful if bi-planar fluoroscopy is available, yet implantation of three radio-opaque markers in each segment of interest may be impractical. Herein we introduce scientific rotoscoping (SR), a new method of motion analysis that uses articulated bone models to simultaneously animate and quantify moving skeletons without markers. The three-step process is described using examples from our work on pigeon flight and alligator walking. First, the experimental scene is reconstructed in 3-D using commercial animation software so that frames of undistorted fluoroscopic and standard video can be viewed in their correct spatial context through calibrated virtual cameras. Second, polygonal models of relevant bones are created from CT or laser scans and rearticulated into a hierarchical marionette controlled by virtual joints. Third, the marionette is registered to video images by adjusting each of its degrees of freedom over a sequence of frames. SR outputs high-resolution 3-D kinematic data for multiple, unmarked bones and anatomically accurate animations that can be rendered from any perspective. Rather than generating moving stick figures abstracted from the coordinates of independent surface points, SR is a morphology-based method of motion analysis deeply rooted in osteological and arthrological data.

  11. A stabilized complementarity formulation for nonlinear analysis of 3D bimodular materials

    NASA Astrophysics Data System (ADS)

    Zhang, L.; Zhang, H. W.; Wu, J.; Yan, B.

    2016-06-01

    Bi-modulus materials with different mechanical responses in tension and compression are often found in civil, composite, and biological engineering. Numerical analysis of bimodular materials is strongly nonlinear and convergence is usually a problem for traditional iterative schemes. This paper aims to develop a stabilized computational method for nonlinear analysis of 3D bimodular materials. Based on the parametric variational principle, a unified constitutive equation of 3D bimodular materials is proposed, which allows the eight principal stress states to be indicated by three parametric variables introduced in the principal stress directions. The original problem is transformed into a standard linear complementarity problem (LCP) by the parametric virtual work principle and a quadratic programming algorithm is developed by solving the LCP with the classic Lemke's algorithm. Update of elasticity and stiffness matrices is avoided and, thus, the proposed algorithm shows an excellent convergence behavior compared with traditional iterative schemes. Numerical examples show that the proposed method is valid and can accurately analyze mechanical responses of 3D bimodular materials. Also, stability of the algorithm is greatly improved.

  12. Quantitative analysis and feature recognition in 3-D microstructural data sets

    NASA Astrophysics Data System (ADS)

    Lewis, A. C.; Suh, C.; Stukowski, M.; Geltmacher, A. B.; Spanos, G.; Rajan, K.

    2006-12-01

    A three-dimensional (3-D) reconstruction of an austenitic stainless-steel microstructure was used as input for an image-based finite-element model to simulate the anisotropic elastic mechanical response of the microstructure. The quantitative data-mining and data-warehousing techniques used to correlate regions of high stress with critical microstructural features are discussed. Initial analysis of elastic stresses near grain boundaries due to mechanical loading revealed low overall correlation with their location in the microstructure. However, the use of data-mining and feature-tracking techniques to identify high-stress outliers revealed that many of these high-stress points are generated near grain boundaries and grain edges (triple junctions). These techniques also allowed for the differentiation between high stresses due to boundary conditions of the finite volume reconstructed, and those due to 3-D microstructural features.

  13. Thermal analysis modeling and simulation of spent nuclear fuel canister using CFDS-FLOW3D

    SciTech Connect

    Lee, S.Y.

    1995-04-01

    The computational fluid dynamics (CFD) code CFDS-FLOW3D (version 3.3) has been utilized to model a three-dimensional thermal analysis of the spent nuclear fuel dry storage mockup test. The Experimental Thermal-Fluids (ETF) group obtained experimental data to benchmark computer codes for verifying the dry storage of aluminum-clad spent nu clear fuel. This report provides CFDS-FLOW3D detailed predictions and benchmark, against the test data. Close comparison of the computational results with the experimental data provide verification that the code can be used to predict reasonably accurate convective flow and thermal behavior of a typical foreign research reactor fuel, such as the Material and Testing Reactor (MTR) design tested, while stored in a dry storage facility.

  14. Experimental analysis of mechanical response of stabilized occipitocervical junction by 3D mark tracking technique

    NASA Astrophysics Data System (ADS)

    Germaneau, A.; Doumalin, P.; Dupré, J. C.; Brèque, C.; Brémand, F.; D'Houtaud, S.; Rigoard, P.

    2010-06-01

    This study is about a biomechanical comparison of some stabilization solutions for the occipitocervical junction. Four kinds of occipito-cervical fixations are analysed in this work: lateral plates fixed by two kinds of screws, lateral plates fixed by hooks and median plate. To study mechanical rigidity of each one, tests have been performed on human skulls by applying loadings and by studying mechanical response of fixations and bone. For this experimental analysis, a specific setup has been developed to impose a load corresponding to the flexion-extension physiological movements. 3D mark tracking technique is employed to measure 3D displacement fields on the bone and on the fixations. Observations of displacement evolution on the bone according to the fixation show different rigidities given by each solution.

  15. System for the Analysis and Visualization of Large 3D Anatomical Trees

    PubMed Central

    Yu, Kun-Chang; Ritman, Erik L.; Higgins, William E.

    2007-01-01

    Modern micro-CT and multi-detector helical CT scanners can produce high-resolution 3D digital images of various anatomical trees. The large size and complexity of these trees make it essentially impossible to define them interactively. Automatic approaches have been proposed for a few specific problems, but none of these approaches guarantee extracting geometrically accurate multi-generational tree structures. This paper proposes an interactive system for defining and visualizing large anatomical trees and for subsequent quantitative data mining. The system consists of a large number of tools for automatic image analysis, semi-automatic and interactive tree editing, and an assortment of visualization tools. Results are presented for a variety of 3D high-resolution images. PMID:17669390

  16. 3D analysis of the performances degradation caused by series resistance in concentrator solar cells

    SciTech Connect

    Daliento, Santolo; Lancellotti, Laura

    2010-01-15

    This paper deals with the modeling of series resistance components in silicon concentrator solar cells. The main components of the macroscopic series resistance are analyzed by means of one-dimensional (1D), two-dimensional (2D), and three-dimensional (3D) numerical simulations. It is shown that the contribution of the lateral current flux, flowing along the emitter region, and of the transverse current flux, flowing along the metal grid, cannot be neglected and, hence, the operation of solar cells subjected to high current densities cannot be described by simple one-dimensional models. The percentage weight of 2D and 3D components on the total value of the series resistance is evaluated and rules for the proper design of the cell geometries are given. An analysis of the effectiveness of the most popular methods for the extraction of the series resistance from the I-V curves of solar cells is also proposed. (author)

  17. Spatio-temporal registration in multiplane MRI acquisitions for 3D colon motiliy analysis

    NASA Astrophysics Data System (ADS)

    Kutter, Oliver; Kirchhoff, Sonja; Berkovich, Marina; Reiser, Maximilian; Navab, Nassir

    2008-03-01

    In this paper we present a novel method for analyzing and visualizing dynamic peristaltic motion of the colon in 3D from two series of differently oriented 2D MRI images. To this end, we have defined an MRI examination protocol, and introduced methods for spatio-temporal alignment of the two MRI image series into a common reference. This represents the main contribution of this paper, which enables the 3D analysis of peristaltic motion. The objective is to provide a detailed insight into this complex motion, aiding in the diagnosis and characterization of colon motion disorders. We have applied the proposed spatio-temporal method on Cine MRI data sets of healthy volunteers. The results have been inspected and validated by an expert radiologist. Segmentation and cylindrical approximation of the colon results in a 4D visualization of the peristaltic motion.

  18. Quasimodes instability analysis of uncertain asymmetric rotor system based on 3D solid element model

    NASA Astrophysics Data System (ADS)

    Zuo, Yanfei; Wang, Jianjun; Ma, Weimeng

    2017-03-01

    Uncertainties are considered in the equation of motion of an asymmetric rotor system. Based on Hill's determinant method, quasimodes stability analysis with uncertain parameters is used to get stochastic boundaries of unstable regions. Firstly, A 3D finite element rotor model was built in rotating frame with four parameterized coefficients, which is assumed as random parameters representing the uncertainties existing in the rotor system. Then the influences of uncertain coefficients on the distribution of the unstable region boundaries are analyzed. The results show that uncertain parameters have various influences on the size, boundary and number of unstable regions. At last, the statistic results of the minimum and maximum spin speeds of unstable regions were got by Monte Carlo simulation. The used method is suitable for real engineering rotor system, because arbitrary configuration of rotors can be modeled by 3D finite element.

  19. Analysis of the 3D Structure and Velocity of a CME on 2 January 2008

    NASA Astrophysics Data System (ADS)

    López, F. M.; Cremades, H.

    We perform an analysis of the 3D structure and velocity of a CME (coronal mass ejection) ejected on 2 January 2008. The event was imaged by both STEREO A and B spacecraft (mutual separation of ˜44°), providing polarized images of the event from two different points of view. To obtain information on the 3D structure of the CME from polarized images, a polarization technique (Moran & Davila, Science 305, 66, 2003) is applied. Aided by this method, we have constructed topographical maps which show the height of the various event features from the plane of the sky (i.e. toward or away from the observer) and have dinamically analyzed and compared the real and projected on the plane of the sky velocities.

  20. Mechanical performance and parameter sensitivity analysis of 3D braided composites joints.

    PubMed

    Wu, Yue; Nan, Bo; Chen, Liang

    2014-01-01

    3D braided composite joints are the important components in CFRP truss, which have significant influence on the reliability and lightweight of structures. To investigate the mechanical performance of 3D braided composite joints, a numerical method based on the microscopic mechanics is put forward, the modeling technologies, including the material constants selection, element type, grid size, and the boundary conditions, are discussed in detail. Secondly, a method for determination of ultimate bearing capacity is established, which can consider the strength failure. Finally, the effect of load parameters, geometric parameters, and process parameters on the ultimate bearing capacity of joints is analyzed by the global sensitivity analysis method. The results show that the main pipe diameter thickness ratio γ, the main pipe diameter D, and the braided angle α are sensitive to the ultimate bearing capacity N.

  1. Mechanical Performance and Parameter Sensitivity Analysis of 3D Braided Composites Joints

    PubMed Central

    Wu, Yue; Nan, Bo; Chen, Liang

    2014-01-01

    3D braided composite joints are the important components in CFRP truss, which have significant influence on the reliability and lightweight of structures. To investigate the mechanical performance of 3D braided composite joints, a numerical method based on the microscopic mechanics is put forward, the modeling technologies, including the material constants selection, element type, grid size, and the boundary conditions, are discussed in detail. Secondly, a method for determination of ultimate bearing capacity is established, which can consider the strength failure. Finally, the effect of load parameters, geometric parameters, and process parameters on the ultimate bearing capacity of joints is analyzed by the global sensitivity analysis method. The results show that the main pipe diameter thickness ratio γ, the main pipe diameter D, and the braided angle α are sensitive to the ultimate bearing capacity N. PMID:25121121

  2. 3D-modeling of deformed halite hopper crystals by Object Based Image Analysis

    NASA Astrophysics Data System (ADS)

    Leitner, Christoph; Hofmann, Peter; Marschallinger, Robert

    2014-12-01

    Object Based Image Analysis (OBIA) is an established method for analyzing multiscale and multidimensional imagery in a range of disciplines. In the present study this method was used for the 3D reconstruction of halite hopper crystals in a mudrock sample, based on Computed Tomography data. To quantitatively assess the reliability of OBIA results, they were benchmarked against a corresponding "gold standard", a reference 3D model of the halite crystals that was derived by manual expert digitization of the CT images. For accuracy assessment, classical per-scene statistics were extended to per-object statistics. The strength of OBIA was to recognize all objects similar to halite hopper crystals and in particular to eliminate cracks. Using a support vector machine (SVM) classifier on top of OBIA, unsuitable objects like halite crystal clusters, polyhalite-coated crystals and spherical halite crystals were effectively dismissed, but simultaneously the number of well-shaped halites was reduced.

  3. Gait in adolescent idiopathic scoliosis: energy cost analysis.

    PubMed

    Mahaudens, P; Detrembleur, C; Mousny, M; Banse, X

    2009-08-01

    Walking is a very common activity for the human body. It is so common that the musculoskeletal and cardiovascular systems are optimized to have the minimum energetic cost at 4 km/h (spontaneous speed). A previous study showed that lumbar and thoracolumbar adolescent idiopathic scoliosis (AIS) patients exhibit a reduction of shoulder, pelvic, and hip frontal mobility during gait. A longer contraction duration of the spinal and pelvic muscles was also noted. The energetic cost (C) of walking is normally linked to the actual mechanical work muscles have to perform. This total mechanical work (W(tot)) can be divided in two parts: the work needed to move the shoulders and lower limbs relative to the center of mass of the body (COM(b)) is known as the internal work (W(int)), whereas additional work, known as external work (W(ext)), is needed to accelerate and lift up the COM(b) relative to the ground. Normally, the COM(b) goes up and down by 3 cm with every step. Pathological walking usually leads to an increase in W (tot) (often because of increased vertical displacement of the COM(b)), and consequently, it increases the energetic cost. The goal of this study is to investigate the effects of scoliosis and scoliosis severity on the mechanical work and energetic cost of walking. Fifty-four female subjects aged 12 to 17 were used in this study. Thirteen healthy girls were in the control group, 12 were in scoliosis group 1 (Cobb angle [Cb] < or = 20 degrees), 13 were in scoliosis group 2 (20 degrees < Cb < 40 degrees), and 16 were in scoliosis group 3 (Cb > or = 40 degrees). They were assessed by physical examination and gait analysis. The 41 scoliotic patients had an untreated progressive left thoracolumbar or lumbar AIS. During gait analysis, the subject was asked to walk on a treadmill at 4 km h(-1). Movements of the limbs were followed by six infrared cameras, which tracked markers fixed on the body. W(int) was calculated from the kinematics. The movements of the COM

  4. 3D structure tensor analysis of light microscopy data for validating diffusion MRI

    PubMed Central

    Khan, Ahmad Raza; Cornea, Anda; Leigland, Lindsey A.; Kohama, Steven G.; Jespersen, Sune Nørhøj; Kroenke, Christopher D.

    2015-01-01

    Diffusion magnetic resonance imaging (d-MRI) is a powerful non-invasive and non-destructive technique for characterizing brain tissue on the microscopic scale. However, the lack of validation of d-MRI by independent experimental means poses an obstacle to accurate interpretation of data acquired using this method. Recently, structure tensor analysis has been applied to light microscopy images, and this technique holds promise to be a powerful validation strategy for d-MRI. Advantages of this approach include its similarity to d-MRI in terms of averaging the effects of a large number of cellular structures, and its simplicity, which enables it to be implemented in a high-throughput manner. However, a drawback of previous implementations of this technique arises from it being restricted to 2D. As a result, structure tensor analyses have been limited to tissue sectioned in a direction orthogonal to the direction of interest. Here we describe the analytical framework for extending structure tensor analysis to 3D, and utilize the results to analyze serial image “stacks” acquired with confocal microscopy of rhesus macaque hippocampal tissue. Implementation of 3D structure tensor procedures requires removal of sources of anisotropy introduced in tissue preparation and confocal imaging. This is accomplished with image processing steps to mitigate the effects of anisotropic tissue shrinkage, and the effects of anisotropy in the point spread function (PSF). In order to address the latter confound, we describe procedures for measuring the dependence of PSF anisotropy on distance from the microscope objective within tissue. Prior to microscopy, ex vivo d-MRI measurements performed on the hippocampal tissue revealed three regions of tissue with mutually orthogonal directions of least restricted diffusion that correspond to CA1, alveus and inferior longitudinal fasciculus. We demonstrate the ability of 3D structure tensor analysis to identify structure tensor orientations

  5. Gait Analysis From a Single Ear-Worn Sensor: Reliability and Clinical Evaluation for Orthopaedic Patients.

    PubMed

    Jarchi, Delaram; Lo, Benny; Wong, Charence; Ieong, Edmund; Nathwani, Dinesh; Yang, Guang-Zhong

    2016-08-01

    Objective assessment of detailed gait patterns after orthopaedic surgery is important for post-surgical follow-up and rehabilitation. The purpose of this paper is to assess the use of a single ear-worn sensor for clinical gait analysis. A reliability measure is devised for indicating the confidence level of the estimated gait events, allowing it to be used in free-walking environments and for facilitating clinical assessment of orthopaedic patients after surgery. Patient groups prior to or following anterior cruciate ligament (ACL) reconstruction and knee replacement were recruited to assess the proposed method. The ability of the sensor for detailed longitudinal analysis is demonstrated with a group of patients after lower limb reconstruction by considering parameters such as temporal and force-related gait asymmetry derived from gait events. The results suggest that the ear-worn sensor can be used for objective gait assessments of orthopaedic patients without the requirement and expense of an elaborate laboratory setup for gait analysis. It significantly simplifies the monitoring protocol and opens the possibilities for home-based remote patient assessment.

  6. On 3-D inelastic analysis methods for hot section components (base program)

    NASA Technical Reports Server (NTRS)

    Wilson, R. B.; Bak, M. J.; Nakazawa, S.; Banerjee, P. K.

    1986-01-01

    A 3-D Inelastic Analysis Method program is described. This program consists of a series of new computer codes embodying a progression of mathematical models (mechanics of materials, special finite element, boundary element) for streamlined analysis of: (1) combustor liners, (2) turbine blades, and (3) turbine vanes. These models address the effects of high temperatures and thermal/mechanical loadings on the local (stress/strain)and global (dynamics, buckling) structural behavior of the three selected components. Three computer codes, referred to as MOMM (Mechanics of Materials Model), MHOST (Marc-Hot Section Technology), and BEST (Boundary Element Stress Technology), have been developed and are briefly described in this report.

  7. Three-dimensional inelastic analysis for hot section components, BEST 3D code

    NASA Technical Reports Server (NTRS)

    Wilson, Raymond B.; Banerjee, Prasanta K.

    1987-01-01

    The goal is the development of an alternative stress analysis tool, distinct from the finite element method, applicable to the engineering analysis of gas turbine engine structures. The boundary element method was selected for this development effort on the basis of its already demonstrated applicability to a variety of geometries and problem types characteristic of gas turbine engine components. Major features of the BEST3D computer program are described, and some of the significant developments carried out as part of the Inelastic Methods Contract are outlined.

  8. Deep brain stimulation improves gait velocity in Parkinson's disease: a systematic review and meta-analysis.

    PubMed

    Roper, Jaimie A; Kang, Nyeonju; Ben, Juliana; Cauraugh, James H; Okun, Michael S; Hass, Chris J

    2016-06-01

    In Parkinson's disease (PD), slow gait speed is significantly related to clinical ratings of disease severity, impaired performance of daily activities, as well as increased overall disability. Conducting a meta-analysis on gait speed is an objective and quantitative technique to summarize the effectiveness of DBS and to determine the effect sizes for future studies. We conducted a systematic review and meta-analysis that analyzed the effects of deep brain stimulation (DBS) surgery on gait speed in patients with PD to gain fundamental insight into the nature of therapeutic effectiveness. A random effects model meta-analysis on 27 studies revealed a significant overall standardized mean difference medium effect size equal to 0.60 (SE = 0.06; p < 0.0001; Z = 10.58). Based on our synthesis of the 27 studies, we determined the following: (1) a significant and medium effect size indicating DBS improves gait speed; (2) DBS improved gait speed regardless of whether the patients were tested in the on or off medication state; (3) both bilateral and unilateral DBS led to gait speed improvement; (4) the effects of DBS on gait speed in the data collection sessions after surgery (DBS on vs. off) were comparable with data collection before surgery (before surgery vs. DBS after surgery); and (5) when evaluating the effects of DBS and medication on gait speed suprathreshold doses were comparable to normal dosages of medication and DBS. The current analysis provides objective evidence that both unilateral and bilateral DBS provide a therapeutic benefit on gait speed in persons with PD.

  9. Lacunarity analysis of raster datasets and 1D, 2D, and 3D point patterns

    NASA Astrophysics Data System (ADS)

    Dong, Pinliang

    2009-10-01

    Spatial scale plays an important role in many fields. As a scale-dependent measure for spatial heterogeneity, lacunarity describes the distribution of gaps within a set at multiple scales. In Earth science, environmental science, and ecology, lacunarity has been increasingly used for multiscale modeling of spatial patterns. This paper presents the development and implementation of a geographic information system (GIS) software extension for lacunarity analysis of raster datasets and 1D, 2D, and 3D point patterns. Depending on the application requirement, lacunarity analysis can be performed in two modes: global mode or local mode. The extension works for: (1) binary (1-bit) and grey-scale datasets in any raster format supported by ArcGIS and (2) 1D, 2D, and 3D point datasets as shapefiles or geodatabase feature classes. For more effective measurement of lacunarity for different patterns or processes in raster datasets, the extension allows users to define an area of interest (AOI) in four different ways, including using a polygon in an existing feature layer. Additionally, directionality can be taken into account when grey-scale datasets are used for local lacunarity analysis. The methodology and graphical user interface (GUI) are described. The application of the extension is demonstrated using both simulated and real datasets, including Brodatz texture images, a Spaceborne Imaging Radar (SIR-C) image, simulated 1D points on a drainage network, and 3D random and clustered point patterns. The options of lacunarity analysis and the effects of polyline arrangement on lacunarity of 1D points are also discussed. Results from sample data suggest that the lacunarity analysis extension can be used for efficient modeling of spatial patterns at multiple scales.

  10. Action Sport Cameras as an Instrument to Perform a 3D Underwater Motion Analysis

    PubMed Central

    Cerveri, Pietro; Barros, Ricardo M. L.; Marins, João C. B.; Silvatti, Amanda P.

    2016-01-01

    Action sport cameras (ASC) are currently adopted mainly for entertainment purposes but their uninterrupted technical improvements, in correspondence of cost decreases, are going to disclose them for three-dimensional (3D) motion analysis in sport gesture study and athletic performance evaluation quantitatively. Extending this technology to sport analysis however still requires a methodologic step-forward to making ASC a metric system, encompassing ad-hoc camera setup, image processing, feature tracking, calibration and 3D reconstruction. Despite traditional laboratory analysis, such requirements become an issue when coping with both indoor and outdoor motion acquisitions of athletes. In swimming analysis for example, the camera setup and the calibration protocol are particularly demanding since land and underwater cameras are mandatory. In particular, the underwater camera calibration can be an issue affecting the reconstruction accuracy. In this paper, the aim is to evaluate the feasibility of ASC for 3D underwater analysis by focusing on camera setup and data acquisition protocols. Two GoPro Hero3+ Black (frequency: 60Hz; image resolutions: 1280×720/1920×1080 pixels) were located underwater into a swimming pool, surveying a working volume of about 6m3. A two-step custom calibration procedure, consisting in the acquisition of one static triad and one moving wand, carrying nine and one spherical passive markers, respectively, was implemented. After assessing camera parameters, a rigid bar, carrying two markers at known distance, was acquired in several positions within the working volume. The average error upon the reconstructed inter-marker distances was less than 2.5mm (1280×720) and 1.5mm (1920×1080). The results of this study demonstrate that the calibration of underwater ASC is feasible enabling quantitative kinematic measurements with accuracy comparable to traditional motion capture systems. PMID:27513846

  11. Action Sport Cameras as an Instrument to Perform a 3D Underwater Motion Analysis.

    PubMed

    Bernardina, Gustavo R D; Cerveri, Pietro; Barros, Ricardo M L; Marins, João C B; Silvatti, Amanda P

    2016-01-01

    Action sport cameras (ASC) are currently adopted mainly for entertainment purposes but their uninterrupted technical improvements, in correspondence of cost decreases, are going to disclose them for three-dimensional (3D) motion analysis in sport gesture study and athletic performance evaluation quantitatively. Extending this technology to sport analysis however still requires a methodologic step-forward to making ASC a metric system, encompassing ad-hoc camera setup, image processing, feature tracking, calibration and 3D reconstruction. Despite traditional laboratory analysis, such requirements become an issue when coping with both indoor and outdoor motion acquisitions of athletes. In swimming analysis for example, the camera setup and the calibration protocol are particularly demanding since land and underwater cameras are mandatory. In particular, the underwater camera calibration can be an issue affecting the reconstruction accuracy. In this paper, the aim is to evaluate the feasibility of ASC for 3D underwater analysis by focusing on camera setup and data acquisition protocols. Two GoPro Hero3+ Black (frequency: 60Hz; image resolutions: 1280×720/1920×1080 pixels) were located underwater into a swimming pool, surveying a working volume of about 6m3. A two-step custom calibration procedure, consisting in the acquisition of one static triad and one moving wand, carrying nine and one spherical passive markers, respectively, was implemented. After assessing camera parameters, a rigid bar, carrying two markers at known distance, was acquired in several positions within the working volume. The average error upon the reconstructed inter-marker distances was less than 2.5mm (1280×720) and 1.5mm (1920×1080). The results of this study demonstrate that the calibration of underwater ASC is feasible enabling quantitative kinematic measurements with accuracy comparable to traditional motion capture systems.

  12. Spacecraft charging analysis with the implicit particle-in-cell code iPic3D

    SciTech Connect

    Deca, J.; Lapenta, G.; Marchand, R.; Markidis, S.

    2013-10-15

    We present the first results on the analysis of spacecraft charging with the implicit particle-in-cell code iPic3D, designed for running on massively parallel supercomputers. The numerical algorithm is presented, highlighting the implementation of the electrostatic solver and the immersed boundary algorithm; the latter which creates the possibility to handle complex spacecraft geometries. As a first step in the verification process, a comparison is made between the floating potential obtained with iPic3D and with Orbital Motion Limited theory for a spherical particle in a uniform stationary plasma. Second, the numerical model is verified for a CubeSat benchmark by comparing simulation results with those of PTetra for space environment conditions with increasing levels of complexity. In particular, we consider spacecraft charging from plasma particle collection, photoelectron and secondary electron emission. The influence of a background magnetic field on the floating potential profile near the spacecraft is also considered. Although the numerical approaches in iPic3D and PTetra are rather different, good agreement is found between the two models, raising the level of confidence in both codes to predict and evaluate the complex plasma environment around spacecraft.

  13. Detailed analysis of an optimized FPP-based 3D imaging system

    NASA Astrophysics Data System (ADS)

    Tran, Dat; Thai, Anh; Duong, Kiet; Nguyen, Thanh; Nehmetallah, Georges

    2016-05-01

    In this paper, we present detail analysis and a step-by-step implementation of an optimized fringe projection profilometry (FPP) based 3D shape measurement system. First, we propose a multi-frequency and multi-phase shifting sinusoidal fringe pattern reconstruction approach to increase accuracy and sensitivity of the system. Second, phase error compensation caused by the nonlinear transfer function of the projector and camera is performed through polynomial approximation. Third, phase unwrapping is performed using spatial and temporal techniques and the tradeoff between processing speed and high accuracy is discussed in details. Fourth, generalized camera and system calibration are developed for phase to real world coordinate transformation. The calibration coefficients are estimated accurately using a reference plane and several gauge blocks with precisely known heights and by employing a nonlinear least square fitting method. Fifth, a texture will be attached to the height profile by registering a 2D real photo to the 3D height map. The last step is to perform 3D image fusion and registration using an iterative closest point (ICP) algorithm for a full field of view reconstruction. The system is experimentally constructed using compact, portable, and low cost off-the-shelf components. A MATLAB® based GUI is developed to control and synchronize the whole system.

  14. Analysis of 3d Magnetotelluric Measurements Over the Coso Geothermal Field

    NASA Astrophysics Data System (ADS)

    Newman, G. A.; Gasperikova, E.; Hoversten, M.

    2007-12-01

    We have carried out an investigation of the Coso Geothermal field utilizing a dense grid of magnetotelluric (MT) stations plus a single line of contiguous bipole array profiling over the east flank of the field. Motivation for this study is that electrical resistivity/conductivity mapping can contribute to better understanding of enhanced geothermal systems (EGS) by imaging the geometry, bounds and controlling structures in existing production, and by monitoring changes in the underground resistivity properties in the vicinity of injection due to fracture porosity enhancement. Initial analysis of the Coso MT data was carried out using 2D MT imaging technology to construct a starting 3D resistivity model from a series of 2D resistivity images obtained using the inline electric field measurements (Zxy impedance elements) along different measurement transects. This model was then refined through a 3D inversion process. The 3D resisitivity model clearly showed the controlling geological structures influencing well production at Coso and shows correlations with mapped surface features such as faults and regional geoelectric strike. We have also correlated the model with an acoustic and shear velocity model of the field to show that the near-vertical high conductivity (low resistivity) structure on the eastern flank of the producing field is also a zone of increase acoustic velocity and increased Vp/Vs ratio.

  15. 3D imaging for ballistics analysis using chromatic white light sensor

    NASA Astrophysics Data System (ADS)

    Makrushin, Andrey; Hildebrandt, Mario; Dittmann, Jana; Clausing, Eric; Fischer, Robert; Vielhauer, Claus

    2012-03-01

    The novel application of sensing technology, based on chromatic white light (CWL), gives a new insight into ballistic analysis of cartridge cases. The CWL sensor uses a beam of white light to acquire highly detailed topography and luminance data simultaneously. The proposed 3D imaging system combines advantages of 3D and 2D image processing algorithms in order to automate the extraction of firearm specific toolmarks shaped on fired specimens. The most important characteristics of a fired cartridge case are the type of the breech face marking as well as size, shape and location of extractor, ejector and firing pin marks. The feature extraction algorithm normalizes the casing surface and consistently searches for the appropriate distortions on the rim and on the primer. The location of the firing pin mark in relation to the lateral scratches on the rim provides unique rotation invariant characteristics of the firearm mechanisms. Additional characteristics are the volume and shape of the firing pin mark. The experimental evaluation relies on the data set of 15 cartridge cases fired from three 9mm firearms of different manufacturers. The results show very high potential of 3D imaging systems for casing-based computer-aided firearm identification, which is prospectively going to support human expertise.

  16. Energy consumption and gait analysis in children with myelomeningocele.

    PubMed

    Galli, M; Crivellini, M; Fazzi, E; Motta, F

    2000-01-01

    The aim of this study was to determine, in children with different levels of myelomeningocele (MMC), the gait pattern and energy cost of walking with and without ankle-foot orthoses (AFOs). We found that each MMC level was characterised by recognisable gait patterns and that the abnormalities closely reflected the muscle deficits present. Furthermore, the study also introduces new indices for evaluating the energy cost of locomotion and demonstrates that the energy required for walking is increased in children with MMC compared with non disabled children. With respect to barefoot conditions, the use of AFOs leads to an improvement in gait and reduced energy consumption.

  17. A Method for 3D Histopathology Reconstruction Supporting Mouse Microvasculature Analysis

    PubMed Central

    Xu, Yiwen; Pickering, J. Geoffrey; Nong, Zengxuan; Gibson, Eli; Arpino, John-Michael; Yin, Hao; Ward, Aaron D.

    2015-01-01

    Structural abnormalities of the microvasculature can impair perfusion and function. Conventional histology provides good spatial resolution with which to evaluate the microvascular structure but affords no 3-dimensional information; this limitation could lead to misinterpretations of the complex microvessel network in health and disease. The objective of this study was to develop and evaluate an accurate, fully automated 3D histology reconstruction method to visualize the arterioles and venules within the mouse hind-limb. Sections of the tibialis anterior muscle from C57BL/J6 mice (both normal and subjected to femoral artery excision) were reconstructed using pairwise rigid and affine registrations of 5 µm-thick, paraffin-embedded serial sections digitized at 0.25 µm/pixel. Low-resolution intensity-based rigid registration was used to initialize the nucleus landmark-based registration, and conventional high-resolution intensity-based registration method. The affine nucleus landmark-based registration was developed in this work and was compared to the conventional affine high-resolution intensity-based registration method. Target registration errors were measured between adjacent tissue sections (pairwise error), as well as with respect to a 3D reference reconstruction (accumulated error, to capture propagation of error through the stack of sections). Accumulated error measures were lower (p<0.01) for the nucleus landmark technique and superior vasculature continuity was observed. These findings indicate that registration based on automatic extraction and correspondence of small, homologous landmarks may support accurate 3D histology reconstruction. This technique avoids the otherwise problematic “banana-into-cylinder” effect observed using conventional methods that optimize the pairwise alignment of salient structures, forcing them to be section-orthogonal. This approach will provide a valuable tool for high-accuracy 3D histology tissue reconstructions for

  18. Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis

    PubMed Central

    Rossman, Phillip J.; Arani, Arvin; Lake, David S.; Glaser, Kevin J.; Trzasko, Joshua D.; Manduca, Armando; McGee, Kiaran P.; Ehman, Richard L.; Araoz, Philip A.

    2016-01-01

    Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. PMID:27016276

  19. LEWICE3D/GlennHT Particle Analysis of the Honeywell Al502 Low Pressure Compressor

    NASA Technical Reports Server (NTRS)

    Bidwell, Colin S.; Rigby, David L.

    2015-01-01

    A flow and ice particle trajectory analysis was performed for the booster of the Honeywell AL502 engine. The analysis focused on two closely related conditions one of which produced a rollback and another which did not rollback during testing in the Propulsion Systems Lab at NASA Glenn Research Center. The flow analysis was generated using the NASA Glenn GlennHT flow solver and the particle analysis was generated using the NASA Glenn LEWICE3D v3.56 ice accretion software. The flow and particle analysis used a 3D steady flow, mixing plane approach to model the transport of flow and particles through the engine. The inflow conditions for the rollback case were: airspeed, 145 ms; static pressure, 33,373 Pa; static temperature, 253.3 K. The inflow conditions for the non-roll-back case were: airspeed, 153 ms; static pressure, 34,252 Pa; static temperature, 260.1 K. Both cases were subjected to an ice particle cloud with a median volume diameter of 24 microns, an ice water content of 2.0 gm3 and a relative humidity of 100 percent. The most significant difference between the rollback and non-rollback conditions was the inflow static temperature which was 6.8 K higher for the non-rollback case.

  20. Toward a low-cost gait analysis system for clinical and free-living assessment.

    PubMed

    Ladha, Cassim; Del Din, Silvia; Nazarpour, Kianoush; Hickey, Aodhan; Morris, Rosie; Catt, Michael; Rochester, Lynn; Godfrey, Alan

    2016-08-01

    Gait is an important clinical assessment tool since changes in gait may reflect changes in general health. Measurement of gait is a complex process which has been restricted to bespoke clinical facilities until recently. The use of inexpensive wearable technologies is an attractive alternative and offers the potential to assess gait in any environment. In this paper we present the development of a low cost analysis gait system built using entirely open source components. The system is used to capture spatio-temporal gait characteristics derived from an existing conceptual model, sensitive to ageing and neurodegenerative pathology (e.g. Parkinson's disease). We demonstrate the system is suitable for use in a clinical unit and will lead to pragmatic use in a free-living (home) environment. The system consists of a wearable (tri-axial accelerometer and gyroscope) with a Raspberry Pi module for data storage and analysis. This forms ongoing work to develop gait as a low cost diagnostic in modern healthcare.

  1. Poor Gait Performance and Prediction of Dementia: Results From a Meta-Analysis

    PubMed Central

    Beauchet, Olivier; Annweiler, Cédric; Callisaya, Michele L.; De Cock, Anne-Marie; Helbostad, Jorunn L.; Kressig, Reto W.; Srikanth, Velandai; Steinmetz, Jean-Paul; Blumen, Helena M.; Verghese, Joe; Allali, Gilles

    2017-01-01

    Background Poor gait performance predicts risk of developing dementia. No structured critical evaluation has been conducted to study this association yet. The aim of this meta-analysis was to systematically examine the association of poor gait performance with incidence of dementia. Methods An English and French Medline search was conducted in June 2015, with no limit of date, using the medical subject headings terms “Gait” OR “Gait Disorders, Neurologic” OR “Gait Apraxia” OR “Gait Ataxia” AND “Dementia” OR “Frontotemporal Dementia” OR “Dementia, Multi-Infarct” OR “Dementia, Vascular” OR “Alzheimer Disease” OR “Lewy Body Disease” OR “Frontotemporal Dementia With Motor Neuron Disease” (Supplementary Concept). Poor gait performance was defined by standardized tests of walking, and dementia was diagnosed according to international consensus criteria. Four etiologies of dementia were identified: any dementia, Alzheimer disease (AD), vascular dementia (VaD), and non-AD (ie, pooling VaD, mixed dementias, and other dementias). Fixed effects meta-analyses were performed on the estimates in order to generate summary values. Results Of the 796 identified abstracts, 12 (1.5%) were included in this systematic review and meta-analysis. Poor gait performance predicted dementia [pooled hazard ratio (HR) combined with relative risk and odds ratio = 1.53 with P < .001 for any dementia, pooled HR = 1.79 with P < .001 for VaD, HR = 1.89 with P value < .001 for non-AD]. Findings were weaker for predicting AD (HR = 1.03 with P value = .004). Conclusions This meta-analysis provides evidence that poor gait performance predicts dementia. This association depends on the type of dementia; poor gait performance is a stronger predictor of non-AD dementias than AD. PMID:26852960

  2. Novel TOPP descriptors in 3D-QSAR analysis of apoptosis inducing 4-aryl-4H-chromenes: comparison versus other 2D- and 3D-descriptors.

    PubMed

    Sciabola, Simone; Carosati, Emanuele; Cucurull-Sanchez, Lourdes; Baroni, Massimo; Mannhold, Raimund

    2007-10-01

    Novel 3D-descriptors using Triplets Of Pharmacophoric Points (TOPP) were evaluated in QSAR-studies on 80 apoptosis-inducing 4-aryl-4H-chromenes. A predictive QSAR model was obtained using PLS, confirmed by means of internal and external validations. Performance of the TOPP approach was compared with that of other 2D- and 3D-descriptors; statistical analysis indicates that TOPP descriptors perform best. A ranking of TOPP>GRIND>BCI 4096=ECFP>FCFP>GRID-GOLPE>DRAGON>MDL 166 was achieved. Finally, in a 'consensus' analysis predictions obtained using the single methods were compared with an average approach using six out of eight methods. The use of the average is statistically superior to the single methods. Beyond it, the use of several methods can help to easily investigate the presence/absence of outliers according to the 'consensus' of the predicted values: agreement among all the methods indicates a precise prediction, whereas large differences between predicted values (for the same compounds by different methods) would demand caution when using such predictions.

  3. Results of treatment when orthopaedic surgeons follow gait-analysis recommendations in children with CP.

    PubMed

    Lofterød, Bjørn; Terjesen, Terje

    2008-07-01

    The aim of the present study was to assess the outcome of orthopaedic surgery in ambulant children with cerebral palsy, when the orthopaedic surgeons followed the recommendations from preoperative three-dimensional gait analysis. 55 children, mean age 10 y 11 mo, were clinically evaluated by orthopaedic surgeons who proposed a surgical treatment plan. After gait analysis and subsequent surgery, three groups were defined. In group A, there was agreement between clinical proposals, gait-analysis recommendations, and subsequent surgery in 128 specific surgical procedures. In group B, 54 procedures were performed based on gait analysis, although these procedures had not been proposed at the clinical examination. In group C, 55 surgical procedures that had been proposed after clinical evaluation were not performed because of the gait-analysis recommendations. The children underwent follow-up gait analysis 1 to 2 years after the initial analysis. The kinematic results were satisfactory, with improvement in most of the gait parameters in children who had undergone surgery and no significant deterioration in those who were not operated. In group A, there were significant improvements in maximum hip extension in stance, minimum knee flexion in stance, timing of maximum knee flexion in swing and knee range of motion, maximum ankle dorsiflexion in stance, and mean femur rotation in stance. In group B, there were significant improvements in maximum hip extension in stance, minimum knee flexion in stance, and knee range of motion. We conclude that gait analysis was useful in confirming clinical indications for surgery, in defining indications for surgery that had not been clinically proposed, and for excluding or delaying surgery that was clinically proposed.

  4. What's its wave? A 3D analysis of flying snake locomotion

    NASA Astrophysics Data System (ADS)

    Yeaton, Isaac J.; Baumgardner, Grant A.; Weiss, Talia M.; Nave, Gary; Ross, Shane D.; Socha, John J.

    2015-11-01

    Arboreal snakes of the genus Chrysopelea are the only known snakes to glide. To execute aerial locomotion, a snake jumps from a tree into the air while simultaneously flattening its body into an aerodynamically favorable shape. Snake gliding is distinguished by complex, three-dimensional body undulations resulting in a stable glide. However, these undulations have not been sufficiently characterized for a proper dynamical analysis. Here we ask, what is the body waveform employed during a glide, and how does this waveform enhance rotational stability? We report on recent glide experiments in which we recorded the three-dimensional body position during 8.5 m glides using a multi-camera motion-capture system. We quantify the body posture using complex modal analysis, which then serves as input in a variable-geometry rigid-body simulation of the snake while gliding. By separating the inertial and aerodynamic contributions in the equations of motion, we can now quantify the stability of the snake's `gait'. Supported by NSF 1351322.

  5. Semi-automated 3D leaf reconstruction and analysis of trichome patterning from light microscopic images.

    PubMed

    Failmezger, Henrik; Jaegle, Benjamin; Schrader, Andrea; Hülskamp, Martin; Tresch, Achim

    2013-04-01

    Trichomes are leaf hairs that are formed by single cells on the leaf surface. They are known to be involved in pathogen resistance. Their patterning is considered to emerge from a field of initially equivalent cells through the action of a gene regulatory network involving trichome fate promoting and inhibiting factors. For a quantitative analysis of single and double mutants or the phenotypic variation of patterns in different ecotypes, it is imperative to statistically evaluate the pattern reliably on a large number of leaves. Here we present a method that enables the analysis of trichome patterns at early developmental leaf stages and the automatic analysis of various spatial parameters. We focus on the most challenging young leaf stages that require the analysis in three dimensions, as the leaves are typically not flat. Our software TrichEratops reconstructs 3D surface models from 2D stacks of conventional light-microscope pictures. It allows the GUI-based annotation of different stages of trichome development, which can be analyzed with respect to their spatial distribution to capture trichome patterning events. We show that 3D modeling removes biases of simpler 2D models and that novel trichome patterning features increase the sensitivity for inter-accession comparisons.

  6. Elastic shape analysis of cylindrical surfaces for 3D/2D registration in endometrial tissue characterization.

    PubMed

    Samir, Chafik; Kurtek, Sebastian; Srivastava, Anuj; Canis, Michel

    2014-05-01

    We study the problem of joint registration and deformation analysis of endometrial tissue using 3D magnetic resonance imaging (MRI) and 2D trans-vaginal ultrasound (TVUS) measurements. In addition to the different imaging techniques involved in the two modalities, this problem is complicated due to: 1) different patient pose during MRI and TVUS observations, 2) the 3D nature of MRI and 2D nature of TVUS measurements, 3) the unknown intersecting plane for TVUS in MRI volume, and 4) the potential deformation of endometrial tissue during TVUS measurement process. Focusing on the shape of the tissue, we use expert manual segmentation of its boundaries in the two modalities and apply, with modification, recent developments in shape analysis of parametric surfaces to this problem. First, we extend the 2D TVUS curves to generalized cylindrical surfaces through replication, and then we compare them with MRI surfaces using elastic shape analysis. This shape analysis provides a simultaneous registration (optimal reparameterization) and deformation (geodesic) between any two parametrized surfaces. Specifically, it provides optimal curves on MRI surfaces that match with the original TVUS curves. This framework results in an accurate quantification and localization of the deformable endometrial cells for radiologists, and growth characterization for gynecologists and obstetricians. We present experimental results using semi-synthetic data and real data from patients to illustrate these ideas.

  7. Semi-automated 3D Leaf Reconstruction and Analysis of Trichome Patterning from Light Microscopic Images

    PubMed Central

    Schrader, Andrea; Hülskamp, Martin; Tresch, Achim

    2013-01-01

    Trichomes are leaf hairs that are formed by single cells on the leaf surface. They are known to be involved in pathogen resistance. Their patterning is considered to emerge from a field of initially equivalent cells through the action of a gene regulatory network involving trichome fate promoting and inhibiting factors. For a quantitative analysis of single and double mutants or the phenotypic variation of patterns in different ecotypes, it is imperative to statistically evaluate the pattern reliably on a large number of leaves. Here we present a method that enables the analysis of trichome patterns at early developmental leaf stages and the automatic analysis of various spatial parameters. We focus on the most challenging young leaf stages that require the analysis in three dimensions, as the leaves are typically not flat. Our software TrichEratops reconstructs 3D surface models from 2D stacks of conventional light-microscope pictures. It allows the GUI-based annotation of different stages of trichome development, which can be analyzed with respect to their spatial distribution to capture trichome patterning events. We show that 3D modeling removes biases of simpler 2D models and that novel trichome patterning features increase the sensitivity for inter-accession comparisons. PMID:23637587

  8. 3D visualisation and analysis of single and coalescing tracks in Solid state Nuclear Track Detectors

    NASA Astrophysics Data System (ADS)

    Wertheim, David; Gillmore, Gavin; Brown, Louise; Petford, Nick

    2010-05-01

    Exposure to radon gas (222Rn) and associated ionising decay products can cause lung cancer in humans (1). Solid state Nuclear Track Detectors (SSNTDs) can be used to monitor radon concentrations (2). Radon particles form tracks in the detectors and these tracks can be etched in order to enable 2D surface image analysis. We have previously shown that confocal microscopy can be used for 3D visualisation of etched SSNTDs (3). The aim of the study was to further investigate track angles and patterns in SSNTDs. A 'LEXT' confocal laser scanning microscope (Olympus Corporation, Japan) was used to acquire 3D image datasets of five CR-39 plastic SSNTD's. The resultant 3D visualisations were analysed by eye and inclination angles assessed on selected tracks. From visual assessment, single isolated tracks as well as coalescing tracks were observed on the etched detectors. In addition varying track inclination angles were observed. Several different patterns of track formation were seen such as single isolated and double coalescing tracks. The observed track angles of inclination may help to assess the angle at which alpha particles hit the detector. Darby, S et al. Radon in homes and risk of lung cancer : collaborative analysis of individual data from 13 European case-control studies. British Medical Journal 2005; 330, 223-226. Phillips, P.S., Denman, A.R., Crockett, R.G.M., Gillmore, G., Groves-Kirkby, C.J., Woolridge, A., Comparative Analysis of Weekly vs. Three monthly radon measurements in dwellings. DEFRA Report No., DEFRA/RAS/03.006. (2004). Wertheim D, Gillmore G, Brown L, and Petford N. A new method of imaging particle tracks in Solid State Nuclear Track Detectors. Journal of Microscopy 2010; 237: 1-6.

  9. Wavelet-based fMRI analysis: 3-D denoising, signal separation, and validation metrics.

    PubMed

    Khullar, Siddharth; Michael, Andrew; Correa, Nicolle; Adali, Tulay; Baum, Stefi A; Calhoun, Vince D

    2011-02-14

    We present a novel integrated wavelet-domain based framework (w-ICA) for 3-D denoising functional magnetic resonance imaging (fMRI) data followed by source separation analysis using independent component analysis (ICA) in the wavelet domain. We propose the idea of a 3-D wavelet-based multi-directional denoising scheme where each volume in a 4-D fMRI data set is sub-sampled using the axial, sagittal and coronal geometries to obtain three different slice-by-slice representations of the same data. The filtered intensity value of an arbitrary voxel is computed as an expected value of the denoised wavelet coefficients corresponding to the three viewing geometries for each sub-band. This results in a robust set of denoised wavelet coefficients for each voxel. Given the de-correlated nature of these denoised wavelet coefficients, it is possible to obtain more accurate source estimates using ICA in the wavelet domain. The contributions of this work can be realized as two modules: First, in the analysis module we combine a new 3-D wavelet denoising approach with signal separation properties of ICA in the wavelet domain. This step helps obtain an activation component that corresponds closely to the true underlying signal, which is maximally independent with respect to other components. Second, we propose and describe two novel shape metrics for post-ICA comparisons between activation regions obtained through different frameworks. We verified our method using simulated as well as real fMRI data and compared our results against the conventional scheme (Gaussian smoothing+spatial ICA: s-ICA). The results show significant improvements based on two important features: (1) preservation of shape of the activation region (shape metrics) and (2) receiver operating characteristic curves. It was observed that the proposed framework was able to preserve the actual activation shape in a consistent manner even for very high noise levels in addition to significant reduction in false

  10. The complex genetics of gait speed: genome-wide meta-analysis approach

    PubMed Central

    Lunetta, Kathryn L.; Smith, Jennifer A.; Eicher, John D.; Vered, Rotem; Deelen, Joris; Arnold, Alice M.; Buchman, Aron S.; Tanaka, Toshiko; Faul, Jessica D.; Nethander, Maria; Fornage, Myriam; Adams, Hieab H.; Matteini, Amy M.; Callisaya, Michele L.; Smith, Albert V.; Yu, Lei; De Jager, Philip L.; Evans, Denis A.; Gudnason, Vilmundur; Hofman, Albert; Pattie, Alison; Corley, Janie; Launer, Lenore J.; Knopman, Davis S.; Parimi, Neeta; Turner, Stephen T.; Bandinelli, Stefania; Beekman, Marian; Gutman, Danielle; Sharvit, Lital; Mooijaart, Simon P.; Liewald, David C.; Houwing-Duistermaat, Jeanine J.; Ohlsson, Claes; Moed, Matthijs; Verlinden, Vincent J.; Mellström, Dan; van der Geest, Jos N.; Karlsson, Magnus; Hernandez, Dena; McWhirter, Rebekah; Liu, Yongmei; Thomson, Russell; Tranah, Gregory J.; Uitterlinden, Andre G.; Weir, David R.; Zhao, Wei; Starr, John M.; Johnson, Andrew D.; Ikram, M. Arfan; Bennett, David A.; Cummings, Steven R.; Deary, Ian J.; Harris, Tamara B.; Kardia, Sharon L. R.; Mosley, Thomas H.; Srikanth, Velandai K.; Windham, Beverly G.; Newman, Ann B.; Walston, Jeremy D.; Davies, Gail; Evans, Daniel S.; Slagboom, Eline P.; Ferrucci, Luigi; Kiel, Douglas P.; Murabito, Joanne M.; Atzmon, Gil

    2017-01-01

    Emerging evidence suggests that the basis for variation in late-life mobility is attributable, in part, to genetic factors, which may become increasingly important with age. Our objective was to systematically assess the contribution of genetic variation to gait speed in older individuals. We conducted a meta-analysis of gait speed GWASs in 31,478 older adults from 17 cohorts of the CHARGE consortium, and validated our results in 2,588 older adults from 4 independent studies. We followed our initial discoveries with network and eQTL analysis of candidate signals in tissues. The meta-analysis resulted in a list of 536 suggestive genome wide significant SNPs in or near 69 genes. Further interrogation with Pathway Analysis placed gait speed as a polygenic complex trait in five major networks. Subsequent eQTL analysis revealed several SNPs significantly associated with the expression of PRSS16, WDSUB1 and PTPRT, which in addition to the meta-analysis and pathway suggested that genetic effects on gait speed may occur through synaptic function and neuronal development pathways. No genome-wide significant signals for gait speed were identified from this moderately large sample of older adults, suggesting that more refined physical function phenotypes will be needed to identify the genetic basis of gait speed in aging. PMID:28077804

  11. Analysis of the Possibilities of Using Low-Cost Scanning System in 3d Modeling

    NASA Astrophysics Data System (ADS)

    Kedzierski, M.; Wierzbickia, D.; Fryskowska, A.; Chlebowska, B.

    2016-06-01

    The laser scanning technique is still a very popular and fast growing method of obtaining information on modeling 3D objects. The use of low-cost miniature scanners creates new opportunities for small objects of 3D modeling based on point clouds acquired from the scan. The same, the development of accuracy and methods of automatic processing of this data type is noticeable. The article presents methods of collecting raw datasets in the form of a point-cloud using a low-cost ground-based laser scanner FabScan. As part of the research work 3D scanner from an open source FabLab project was constructed. In addition, the results for the analysis of the geometry of the point clouds obtained by using a low-cost laser scanner were presented. Also, some analysis of collecting data of different structures (made of various materials such as: glass, wood, paper, gum, plastic, plaster, ceramics, stoneware clay etc. and of different shapes: oval and similar to oval and prism shaped) have been done. The article presents two methods used for analysis: the first one - visual (general comparison between the 3D model and the real object) and the second one - comparative method (comparison between measurements on models and scanned objects using the mean error of a single sample of observations). The analysis showed, that the low-budget ground-based laser scanner FabScan has difficulties with collecting data of non-oval objects. Items built of glass painted black also caused problems for the scanner. In addition, the more details scanned object contains, the lower the accuracy of the collected point-cloud is. Nevertheless, the accuracy of collected data (using oval-straight shaped objects) is satisfactory. The accuracy, in this case, fluctuates between ± 0,4 mm and ± 1,0 mm whereas when using more detailed objects or a rectangular shaped prism the accuracy is much more lower, between 2,9 mm and ± 9,0 mm. Finally, the publication presents the possibility (for the future expansion of

  12. From Heteroaromatic Acids and Imines to Azaspirocycles: Stereoselective Synthesis and 3D Shape Analysis

    PubMed Central

    Chambers, Sarah J.; Coulthard, Graeme; Unsworth, William P.; O'Brien, Peter

    2016-01-01

    Abstract Heteroaromatic carboxylic acids have been directly coupled with imines using propylphosphonic anhydride (T3P) and NEt(iPr)2 to form azaspirocycles via intermediate N‐acyliminium ions. Spirocyclic indolenines (3H‐indoles), azaindolenines, 2H‐pyrroles and 3H‐pyrroles were all accessed using this metal‐free approach. The reactions typically proceed with high diastereoselectivity and 3D shape analysis confirms that the products formed occupy areas of chemical space that are under‐represented in existing drugs and high throughput screening libraries. PMID:26918778

  13. CASMO5/TSUNAMI-3D spent nuclear fuel reactivity uncertainty analysis

    SciTech Connect

    Ferrer, R.; Rhodes, J.; Smith, K.

    2012-07-01

    The CASMO5 lattice physics code is used in conjunction with the TSUNAMI-3D sequence in ORNL's SCALE 6 code system to estimate the uncertainties in hot-to-cold reactivity changes due to cross-section uncertainty for PWR assemblies at various burnup points. The goal of the analysis is to establish the multiplication factor uncertainty similarity between various fuel assemblies at different conditions in a quantifiable manner and to obtain a bound on the hot-to-cold reactivity uncertainty over the various assembly types and burnup attributed to fundamental cross-section data uncertainty. (authors)

  14. 3-D inelastic analysis methods for hot section components. Volume 2: Advanced special functions models

    NASA Technical Reports Server (NTRS)

    Wilson, R. B.; Banerjee, P. K.

    1987-01-01

    This Annual Status Report presents the results of work performed during the third year of the 3-D Inelastic Analysis Methods for Hot Sections Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of computer codes that permit more accurate and efficient three-dimensional analyses of selected hot section components, i.e., combustor liners, turbine blades, and turbine vanes. The computer codes embody a progression of mathematical models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components.

  15. Gait and jump analysis in healthy cats using a pressure mat system.

    PubMed

    Stadig, Sarah M; Bergh, Anna K

    2015-06-01

    Physical orthopaedic examination in cats does not always reveal signs of lameness and no objective gait analysis method has yet been standardised for use in cats. The aims of the present study were to define appropriate parameters for pressure mat analyses during walk and jump, and to define reference values for gait parameters of healthy cats. Further, the distribution of the vertical force within the paws and the influence of a non-centred head position were investigated. The hypothesis was that cats have a symmetrical gait, a front/hindlimb asymmetry similar to dogs, and that peak vertical force (PVF) and vertical impulse (VI) have high intraclass correlation coefficients, confirming the reliability of these parameters. Data for walking (n = 46) showed gait symmetry indices of close to 1.0, besides PVF front/hind (1.3 ± 0.2). The PVF front/hind for jumping cats (n = 16) was 1.7 ± 0.6. Results from the distribution of the vertical force within the paw (n = 39) showed that the main weight during a strike is transferred from the caudal towards the craniomedial part of the paw. The findings support the hypothesis that healthy cats have similar gait symmetry to healthy dogs and that PVF and VI are reliable gait parameters. In conclusion, the present study provides a reference interval for healthy cats. Further studies are needed to investigate gait parameters in cats with orthopaedic disease.

  16. Error analysis in stereo vision for location measurement of 3D point

    NASA Astrophysics Data System (ADS)

    Li, Yunting; Zhang, Jun; Tian, Jinwen

    2015-12-01

    Location measurement of 3D point in stereo vision is subjected to different sources of uncertainty that propagate to the final result. For current methods of error analysis, most of them are based on ideal intersection model to calculate the uncertainty region of point location via intersecting two fields of view of pixel that may produce loose bounds. Besides, only a few of sources of error such as pixel error or camera position are taken into account in the process of analysis. In this paper we present a straightforward and available method to estimate the location error that is taken most of source of error into account. We summed up and simplified all the input errors to five parameters by rotation transformation. Then we use the fast algorithm of midpoint method to deduce the mathematical relationships between target point and the parameters. Thus, the expectations and covariance matrix of 3D point location would be obtained, which can constitute the uncertainty region of point location. Afterwards, we turned back to the error propagation of the primitive input errors in the stereo system and throughout the whole analysis process from primitive input errors to localization error. Our method has the same level of computational complexity as the state-of-the-art method. Finally, extensive experiments are performed to verify the performance of our methods.

  17. Three-dimensional (3D) hydrodynamic focusing for continuous sampling and analysis of adherent cells.

    PubMed

    Xu, Chunxiu; Wang, Min; Yin, Xuefeng

    2011-10-07

    A simple three-dimensional (3D) hydrodynamic focusing microfluidic device integrated with continuous sampling, rapid dynamic lysis, capillary electrophoretic (CE) separation and detection of intracellular content is presented. One of the major difficulties in microfluidic cell analysis for adherent cells is that the cells are prone to attaching to the channel surface. To solve this problem, a cross microfluidic chip with three sheath-flow channels located on both sides of and below the sampling channel was developed. With the three sheath flows around the sample solution-containing cells, the formed soft fluid wall prevents the cells from adhering to the channel surface. Labeled cells were 3D hydrodynamically focused by the sheath-flow streams and smoothly introduced into the cross-section one by one. The introduction of sheath-flow streams not only ensured single-cell sampling but avoided blockage of the sampling channel by adherent cells as well. The maximum rate for introduction of individual cells into the separation channel was about 151 cells min(-1). With electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 400 ms at the entry of the channel by sodium dodecylsulfate (SDS) added in the sheath-flow solution. The microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single HepG2 cells. The average analysis throughput of ROS and GSH in single cells was 16-18 cells min(-1).

  18. Analysis of Uncertainty and Repeatability of a Low-Cost 3D Laser Scanner

    PubMed Central

    Polo, María-Eugenia; Felicísimo, Ángel M.

    2012-01-01

    Portable 3D laser scanners are a valuable tool for compiling elaborate digital collections of archaeological objects and analysing the shapes and dimensions of pieces. Although low-cost desktop 3D laser scanners have powerful capacities, it is important to know their limitations. This paper performs an analysis of the uncertainty and repeatability of the NextEngine™ portable low-cost 3D laser scanner by scanning an object 20 times in two different resolution modes—Macro and Wide. Some dimensions of the object were measured using a digital calliper, and these results were used as the “true” or control data. In comparing the true and the scanned data, we verified that the mean uncertainty in the Macro Mode is approximately half that of the Wide Mode, at ±0.81 mm and ±1.66 mm, respectively. These experimental results are significantly higher than the accuracy specifications provided by the manufacturer. An analysis of repeatability shows that the successive replicates do not match in the same position. The results are better in Macro Mode than in Wide Mode; it is observed that the repeatability factor is slightly larger than the corresponding mode accuracy, with ±0.84 vs. ±0.81 mm in Macro Mode and ±1.82 vs. ±1.66 mm in Wide Mode. We suggest several improvements, such as adding an external reference scale or providing a calibrated object to allow for a self-calibration operation of the scanner. PMID:23012532

  19. Principal component analysis of gait kinematics data in acute and chronic stroke patients.

    PubMed

    Milovanović, Ivana; Popović, Dejan B

    2012-01-01

    We present the joint angles analysis by means of the principal component analysis (PCA). The data from twenty-seven acute and chronic hemiplegic patients were used and compared with data from five healthy subjects. The data were collected during walking along a 10-meter long path. The PCA was applied on a data set consisting of hip, knee, and ankle joint angles of the paretic and the nonparetic leg. The results point to significant differences in joint synergies between the acute and chronic hemiplegic patients that are not revealed when applying typical methods for gait assessment (clinical scores, gait speed, and gait symmetry). The results suggest that the PCA allows classification of the origin for the deficit in the gait when compared to healthy subjects; hence, the most appropriate treatment can be applied in the rehabilitation.

  20. Analysis of fracture networks in a reservoir dolomite by 3D micro-imaging

    NASA Astrophysics Data System (ADS)

    Voorn, Maarten; Hoyer, Stefan; Exner, Ulrike; Reuschlé, Thierry

    2013-04-01

    Narrow fractures in reservoir rocks can be of great importance when determining the hydrocarbon potential of such a reservoir. Such fractures can contribute significantly to - or even be dominant for - the porosity and permeability characteristics of such rocks. Investigating these narrow fractures is therefore important, but not always trivial. Standard laboratory measurements on sample plugs from a reservoir are not always suitable for fractured rocks. Thin section analysis can provide very important information, but mostly only in 2D. Also other sources of information have major drawbacks, such as FMI (Formation Micro-Imager) during coring (insufficient resolution) and hand specimen analysis (no internal information). 3D imaging of reservoir rock samples is a good alternative and extension to the methods mentioned above. The 3D information is in our case obtained by X-ray Micro-Computed Tomography (µCT) imaging. Our used samples are 2 and 3 cm diameter plugs of a narrowly fractured (apertures generally <200 µm) reservoir dolomite (Hauptdolomit formation) from below the Vienna Basin, Austria. µCT has the large advantage of being non-destructive to the samples, and with the chosen sample sizes and settings, the sample rocks and fractures can be imaged with sufficient quality at sufficient resolution. After imaging, the fracture networks need to be extracted (segmented) from the background. Unfortunately, available segmentation approaches in the literature do not provide satisfactory results on such narrow fractures. We therefore developed the multiscale Hessian fracture filter, with which we are able to extract the fracture networks from the datasets in a better way. The largest advantages of this technique are that it is inherently 3D, runs on desktop computers with limited resources, and is implemented in public domain software (ImageJ / FIJI). The results from the multiscale Hessian fracture filtering approach serve as input for porosity determination. Also

  1. Improved gait recognition by gait dynamics normalization.

    PubMed

    Liu, Zongyi; Sarkar, Sudeep

    2006-06-01

    Potential sources for gait biometrics can be seen to derive from two aspects: gait shape and gait dynamics. We show that improved gait recognition can be achieved after normalization of dynamics and focusing on the shape information. We normalize for gait dynamics using a generic walking model, as captured by a population Hidden Markov Model (pHMM) defined for a set of individuals. The states of this pHMM represent gait stances over one gait cycle and the observations are the silhouettes of the corresponding gait stances. For each sequence, we first use Viterbi decoding of the gait dynamics to arrive at one dynamics-normalized, averaged, gait cycle of fixed length. The distance between two sequences is the distance between the two corresponding dynamics-normalized gait cycles, which we quantify by the sum of the distances between the corresponding gait stances. Distances between two silhouettes from the same generic gait stance are computed in the linear discriminant analysis space so as to maximize the discrimination between persons, while minimizing the variations of the same subject under different conditions. The distance computation is constructed so that it is invariant to dilations and erosions of the silhouettes. This helps us handle variations in silhouette shape that can occur with changing imaging conditions. We present results on three different, publicly available, data sets. First, we consider the HumanlD Gait Challenge data set, which is the largest gait benchmarking data set that is available (122 subjects), exercising five different factors, i.e., viewpoint, shoe, surface, carrying condition, and time. We significantly improve the performance across the hard experiments involving surface change and briefcase carrying conditions. Second, we also show improved performance on the UMD gait data set that exercises time variations for 55 subjects. Third, on the CMU Mobo data set, we show results for matching across different walking speeds. It is worth

  2. An Analysis of Item Identification for Additive Manufacturing (3-D Printing) Within the Naval Supply Chain

    DTIC Science & Technology

    2014-12-01

    has demonstrated an ongoing effort to grow human kidneys using 3D printers . To describe the process succinctly, the 3D printer constructs a frame from...Vartanian, K. (2013). 3D printers : Judgment day. Industrial Laser Solutions, 28(2), 12–15. Retrieved from http://www.industrial-lasers.com/articles...print/volume- 28/issue-2/features/ 3d - printers -judgment-day.html 70 THIS PAGE INTENTIONALLY LEFT BLANK 71 INITIAL DISTRIBUTION LIST 1. Defense

  3. Analysis of Impact of 3D Printing Technology on Traditional Manufacturing Technology

    NASA Astrophysics Data System (ADS)

    Wu, Niyan; Chen, Qi; Liao, Linzhi; Wang, Xin

    With quiet rise of 3D printing technology in automobile, aerospace, industry, medical treatment and other fields, many insiders hold different opinions on its development. This paper objectively analyzes impact of 3D printing technology on mold making technology and puts forward the idea of fusion and complementation of 3D printing technology and mold making technology through comparing advantages and disadvantages of 3D printing mold and traditional mold making technology.

  4. A 3D endoscopy reconstruction as a saliency map for analysis of polyp shapes

    NASA Astrophysics Data System (ADS)

    Ruano, Josue; Martínez, Fabio; Gómez, Martín.; Romero, Eduardo

    2015-01-01

    A first diagnosis of colorectal cancer is performed by examination of polyp shape and appearance during an endoscopy routine procedure. However, the video-endoscopy is highly noisy because exacerbated physiological conditions like increased motility or secretion may limit the visual analysis of lesions. In this work a 3D reconstruction of the digestive tract is proposed, facilitating the polyp shape evaluation by highlighting its surface geometry and allowing an analysis from different perspectives. The method starts by a spatio-temporal map, constructed to group the different regions of the tract by their similar dynamic patterns during the sequence. Then, such map was convolved with a second derivative of a Gaussian kernel that emulates the camera distortion and allows to highlight the polyp surface. The position initialization in each frame of the kernel was computed from expert manual delineation and propagated along the sequence based on. Results show reliable reconstructions, with a salient 3D polyp structure that can then be better observed.

  5. Shape Analysis of 3D Head Scan Data for U.S. Respirator Users

    NASA Astrophysics Data System (ADS)

    Zhuang, Ziqing; Slice, DennisE; Benson, Stacey; Lynch, Stephanie; Viscusi, DennisJ

    2010-12-01

    In 2003, the National Institute for Occupational Safety and Health (NIOSH) conducted a head-and-face anthropometric survey of diverse, civilian respirator users. Of the 3,997 subjects measured using traditional anthropometric techniques, surface scans and 26 three-dimensional (3D) landmark locations were collected for 947 subjects. The objective of this study was to report the size and shape variation of the survey participants using the 3D data. Generalized Procrustes Analysis (GPA) was conducted to standardize configurations of landmarks associated with individuals into a common coordinate system. The superimposed coordinates for each individual were used as commensurate variables that describe individual shape and were analyzed using Principal Component Analysis (PCA) to identify population variation. The first four principal components (PC) account for 49% of the total sample variation. The first PC indicates that overall size is an important component of facial variability. The second PC accounts for long and narrow or short and wide faces. Longer narrow orbits versus shorter wider orbits can be described by PC3, and PC4 represents variation in the degree of ortho/prognathism. Geometric Morphometrics provides a detailed and interpretable assessment of morphological variation that may be useful in assessing respirators and devising new test and certification standards.

  6. A coordinate-free method for the analysis of 3D facial change

    NASA Astrophysics Data System (ADS)

    Mao, Zhili; Siebert, Jan Paul; Cockshott, W. Paul; Ayoub, Ashraf Farouk

    2004-05-01

    Euclidean Distance Matrix Analysis (EDMA) is widely held as the most important coordinate-free method by which to analyze landmarks. It has been used extensively in the field of medical anthropometry and has already produced many useful results. Unfortunately this method renders little information regarding the surface on which these points are located and accordingly is inadequate for the 3D analysis of surface anatomy. Here we shall present a new inverse surface flatness metric, the ratio between the Geodesic and the Euclidean inter-landmark distances. Because this metric also only reflects one aspect of three-dimensional shape, i.e. surface flatness, we have combined it with the Euclidean distance to investigate 3D facial change. The goal of this investigation is to be able to analyze three-dimensional facial change in terms of bilateral symmetry as encoded both by surface flatness and by geometric configuration. Our initial study, based on 25 models of surgically managed children (unilateral cleft lip repair) and 40 models of control children at the age of 2 years, indicates that the faces of the surgically managed group were found to be significantly less symmetric than those of the control group in terms of surface flatness, geometric configuration and overall symmetry.

  7. Detection of ancient morphology and potential hydrocarbon traps using 3-D seismic data and attribute analysis

    SciTech Connect

    Heggland, R.

    1995-12-31

    This paper presents the use of seismic attributes on 3D data to reveal Tertiary and Cretaceous geological features in Norwegian block 9/2. Some of the features would hardly be possible to map using only 2D seismic data. The method which involves a precise interpretation of horizons, attribute analysis and manipulation of colour displays, may be useful when studying morphology, faults and hydrocarbon traps. The interval of interest in this study was from 0 to 1.5 s TWT. Horizontal displays (timeslices and attribute maps), seemed to highlight very nicely geological features such as shallow channels, fractures, karst topography and faults. The attributes used for mapping these features were amplitude, total reflection energy (a volume or time interval attribute), dip and azimuth. The choice of colour scale and manipulation of colour displays were also critical for the results. The data examples clearly demonstrate how it is possible to achieve a very detailed mapping of geological features using 3D seismic data and attribute analysis. The results of this study were useful for the understanding of hydrocarbon migration paths and hydrocarbon traps.

  8. [Application of PARAFAC method and 3-D fluorescence spectra in petroleum pollutant measurement and analysis].

    PubMed

    Pan, Zhao; Wang, Yu-tian; Shao, Xiao-qing; Wu, Xi-jun; Yang, Li-li

    2012-03-01

    A method for identification and concentration measurement of petroleum pollutant by combining three-dimensional (3-D) fluorescence spectra with parallel factor analysis (PARAFAC) was proposed. The main emphasis of research was the measurement of coexisting different kinds of petroleum. The CCl4 solutions of a 0# diesel sample, a 97# gasoline sample, and a kerosene sample were used as measurement objects. The condition of multiple petroleum coexistence was simulated by petroleum solutions with different mixed ratios. The character of PARAFAC in complex mixture coexisting system analysis was studied. The spectra of three kinds of solutions and the spectra of gasoline-diesel mixed samples, diesel-kerosene mixed samples, and gas oline-diesel mixed with small counts of kerosene interference samples were analyzed respectively. The core consistency diagnostic method and residual sum of squares method were applied to calculate the number of factors in PARAFAC. In gasoline-diesel experiment, gasoline or diesel can be identified and measured as a whole respectively by 2-factors parallel factors analysis. In diesel-kerosene experiment, 2-factors parallel factors analysis can only obtain the characters of diesel, and the 3rd factor is needed to separate the kerosene spectral character from the mixture spectrum. When small counts of kerosene exist in gasoline-diesel solution, gasoline and diesel still can be identified and measured as principal components by a 2-factors parallel factor analysis, and the effect of interference on qualitative analysis is not significant. The experiment verified that the PARAFAC method can obtain characteristic spectrum of each kind of petroleum, and the concentration of petroleum in solutions can be predicted simultaneously, with recoveries shown in the paper. The results showed the possibility of petroleum pollutant identification and concentration measurement based on the 3-D fluorescence spectra and PARAFAC.

  9. Analysis of 3D Modeling Software Usage Patterns for K-12 Students

    ERIC Educational Resources Information Center

    Wu, Yi-Chieh; Liao, Wen-Hung; Chi, Ming-Te; Li, Tsai-Yen

    2016-01-01

    In response to the recent trend in maker movement, teachers are learning 3D techniques actively and bringing 3D printing into the classroom to enhance variety and creativity in designing lectures. This study investigates the usage pattern of a 3D modeling software, Qmodel Creator, which is targeted at K-12 students. User logs containing…

  10. Robust object tracking techniques for vision-based 3D motion analysis applications

    NASA Astrophysics Data System (ADS)

    Knyaz, Vladimir A.; Zheltov, Sergey Y.; Vishnyakov, Boris V.

    2016-04-01

    Automated and accurate spatial motion capturing of an object is necessary for a wide variety of applications including industry and science, virtual reality and movie, medicine and sports. For the most part of applications a reliability and an accuracy of the data obtained as well as convenience for a user are the main characteristics defining the quality of the motion capture system. Among the existing systems for 3D data acquisition, based on different physical principles (accelerometry, magnetometry, time-of-flight, vision-based), optical motion capture systems have a set of advantages such as high speed of acquisition, potential for high accuracy and automation based on advanced image processing algorithms. For vision-based motion capture accurate and robust object features detecting and tracking through the video sequence are the key elements along with a level of automation of capturing process. So for providing high accuracy of obtained spatial data the developed vision-based motion capture system "Mosca" is based on photogrammetric principles of 3D measurements and supports high speed image acquisition in synchronized mode. It includes from 2 to 4 technical vision cameras for capturing video sequences of object motion. The original camera calibration and external orientation procedures provide the basis for high accuracy of 3D measurements. A set of algorithms as for detecting, identifying and tracking of similar targets, so for marker-less object motion capture is developed and tested. The results of algorithms' evaluation show high robustness and high reliability for various motion analysis tasks in technical and biomechanics applications.

  11. 3D geometry analysis of the medial meniscus--a statistical shape modeling approach.

    PubMed

    Vrancken, A C T; Crijns, S P M; Ploegmakers, M J M; O'Kane, C; van Tienen, T G; Janssen, D; Buma, P; Verdonschot, N

    2014-10-01

    The geometry-dependent functioning of the meniscus indicates that detailed knowledge on 3D meniscus geometry and its inter-subject variation is essential to design well functioning anatomically shaped meniscus replacements. Therefore, the aim of this study was to quantify 3D meniscus geometry and to determine whether variation in medial meniscus geometry is size- or shape-driven. Also we performed a cluster analysis to identify distinct morphological groups of medial menisci and assessed whether meniscal geometry is gender-dependent. A statistical shape model was created, containing the meniscus geometries of 35 subjects (20 females, 15 males) that were obtained from MR images. A principal component analysis was performed to determine the most important modes of geometry variation and the characteristic changes per principal component were evaluated. Each meniscus from the original dataset was then reconstructed as a linear combination of principal components. This allowed the comparison of male and female menisci, and a cluster analysis to determine distinct morphological meniscus groups. Of the variation in medial meniscus geometry, 53.8% was found to be due to primarily size-related differences and 29.6% due to shape differences. Shape changes were most prominent in the cross-sectional plane, rather than in the transverse plane. Significant differences between male and female menisci were only found for principal component 1, which predominantly reflected size differences. The cluster analysis resulted in four clusters, yet these clusters represented two statistically different meniscal shapes, as differences between cluster 1, 2 and 4 were only present for principal component 1. This study illustrates that differences in meniscal geometry cannot be explained by scaling only, but that different meniscal shapes can be distinguished. Functional analysis, e.g. through finite element modeling, is required to assess whether these distinct shapes actually influence

  12. Utilization and efficacy of computational gait analysis for hamstring lengthening surgery.

    PubMed

    MacWilliams, Bruce A; Stotts, Alan K; Carroll, Kristen L; D'Astous, Jacques L

    2016-09-01

    A retrospective analysis of computational gait studies performed in a single lab over a 12 year period was undertaken to characterize how recommendations to perform or not to perform hamstring lengthenings were utilized by physicians and the effect on outcomes. 131 Subjects were identified as either having hamstring lengthening considered by the referring surgeon, recommended by gait analysis data, or performed. A subset of this data meeting inclusion criteria for pre- and post-surgical timeframes, and bilateral diagnosis was further analyzed to assess the efficacy of the recommendations. There was initial agreement between planned procedures and recommended procedures in just 41% of the cases. Including the cases where there was agreement, gait analysis altered the initial procedure in 54%. In the cases where the initial plan was not supported by gait data, surgeons followed gait recommendations in 77%. In subjects who underwent hamstring lengthening, when surgeons followed or agreed with gait recommendations, patients were 3.6 times more likely to experience a positive outcome.

  13. Ankle arthrodesis. Long-term follow-up with gait analysis.

    PubMed

    Mazur, J M; Schwartz, E; Simon, S R

    1979-10-01

    A functional assessment of twelve patients after ankle arthrodesis for post-traumatic arthritis was carried out by means of an extensive clinical evaluation and gait analysis after an average follow-up of eight years. A weighted point system was developed to grade ankle function clinically. The data on gait analysis were examined to determine the effect of arthrodesis of the ankle on the over-all pattern of walking. Under conditions of normal daily living while wearing shoes, all patients functioned well after arthrodesis. The gait-analysis data obtained with the patients wearing shoes showed excellent gait characteristics, and the ankle motion that had been lost was compensated for by: (1) motion of the small joints of the ipsilateral foot; (2) altered motion of the ankle in the contralateral limb; and (3) appropriate footwear. While the patients were walking barefooted, some adverse effects of fusion of the ankle were evident. Velocity of gait was slowed and the length of stride was shortened in all twelve patients. One patient whose ankle had been fused in an equinus position had a back-knee deformity during stance phase, and another walked only on his toes when he was without shoes. The gait patterns of all patients were markedly improved when they were wearing shoes with appropriate heel heights.

  14. Analysis of bite marks in foodstuffs by computer tomography (cone beam CT)--3D reconstruction.

    PubMed

    Marques, Jeidson; Musse, Jamilly; Caetano, Catarina; Corte-Real, Francisco; Corte-Real, Ana Teresa

    2013-12-01

    The use of three-dimensional (3D) analysis of forensic evidence is highlighted in comparison with traditional methods. This three-dimensional analysis is based on the registration of the surface from a bitten object. The authors propose to use Cone Beam Computed Tomography (CBCT), which is used in dental practice, in order to study the surface and interior of bitten objects and dental casts of suspects. In this study, CBCT is applied to the analysis of bite marks in foodstuffs, which may be found in a forensic case scenario. 6 different types of foodstuffs were used: chocolate, cheese, apple, chewing gum, pizza and tart (flaky pastry and custard). The food was bitten into and dental casts of the possible suspects were made. The dental casts and bitten objects were registered using an x-ray source and the CBCT equipment iCAT® (Pennsylvania, EUA). The software InVivo5® (Anatomage Inc, EUA) was used to visualize and analyze the tomographic slices and 3D reconstructions of the objects. For each material an estimate of its density was assessed by two methods: HU values and specific gravity. All the used materials were successfully reconstructed as good quality 3D images. The relative densities of the materials in study were compared. Amongst the foodstuffs, the chocolate had the highest density (median value 100.5 HU and 1,36 g/cm(3)), while the pizza showed to have the lowest (median value -775 HU and 0,39 g/cm(3)), on both scales. Through tomographic slices and three-dimensional reconstructions it was possible to perform the metric analysis of the bite marks in all the foodstuffs, except for the pizza. These measurements could also be obtained from the dental casts. The depth of the bite mark was also successfully determined in all the foodstuffs except for the pizza. Cone Beam Computed Tomography has the potential to become an important tool for forensic sciences, namely for the registration and analysis of bite marks in foodstuffs that may be found in a crime

  15. Gait profile score and movement analysis profile in patients with Parkinson's disease during concurrent cognitive load

    PubMed Central

    Speciali, Danielli S.; Oliveira, Elaine M.; Cardoso, Jefferson R.; Correa, João C. F.; Baker, Richard; Lucareli, Paulo R. G.

    2014-01-01

    Background: Gait disorders are common in individuals with Parkinson's Disease (PD) and the concurrent performance of motor and cognitive tasks can have marked effects on gait. The Gait Profile Score (GPS) and the Movement Analysis Profile (MAP) were developed in order to summarize the data of kinematics and facilitate understanding of the results of gait analysis. Objective: To investigate the effectiveness of the GPS and MAP in the quantification of changes in gait during a concurrent cognitive load while walking in adults with and without PD. Method: Fourteen patients with idiopathic PD and nine healthy subjects participated in the study. All subjects performed single and dual walking tasks. The GPS/MAP was computed from three-dimensional gait analysis data. Results: Differences were found between tasks for GPS (P<0.05) and Gait Variable Score (GVS) (pelvic rotation, knee flexion-extension and ankle dorsiflexion-plantarflexion) (P<0.05) in the PD group. An interaction between task and group was observed for GPS (P<0.01) for the right side (Cohen's ¯d=0.99), left side (Cohen's ¯d=0.91), and overall (Cohen's ¯d=0.88). No interaction was observed only for hip internal-external rotation and foot internal-external progression GVS variables in the PD group. Conclusions: The results showed gait impairment during the dual task and suggest that GPS/MAP may be used to evaluate the effects of concurrent cognitive load while walking in patients with PD. PMID:25054382

  16. A comparative collision-based analysis of human gait.

    PubMed

    Lee, David V; Comanescu, Tudor N; Butcher, Michael T; Bertram, John E A

    2013-11-22

    This study compares human walking and running, and places them within the context of other mammalian gaits. We use a collision-based approach to analyse the fundamental dynamics of the centre of mass (CoM) according to three angles derived from the instantaneous force and velocity vectors. These dimensionless angles permit comparisons across gait, species and size. The collision angle Φ, which is equivalent to the dimensionless mechanical cost of transport CoTmech, is found to be three times greater during running than walking of humans. This threefold difference is consistent with previous studies of walking versus trotting of quadrupeds, albeit tends to be greater in the gaits of humans and hopping bipeds than in quadrupeds. Plotting the collision angle Φ together with the angles of the CoM force vector Θ and velocity vector Λ results in the functional grouping of bipedal and quadrupedal gaits according to their CoM dynamics-walking, galloping and ambling are distinguished as separate gaits that employ collision reduction, whereas trotting, running and hopping employ little collision reduction and represent more of a continuum that is influenced by dimensionless speed. Comparable with quadrupedal mammals, collision fraction (the ratio of actual to potential collision) is 0.51 during walking and 0.89 during running, indicating substantial collision reduction during walking, but not running, of humans.

  17. Knowledge-Based Analysis And Understanding Of 3D Medical Images

    NASA Astrophysics Data System (ADS)

    Dhawan, Atam P.; Juvvadi, Sridhar

    1988-06-01

    The anatomical three-dimensional (3D) medical imaging modalities, such as X-ray CT and MRI, have been well recognized in the diagnostic radiology for several years while the nuclear medicine modalities, such as PET, have just started making a strong impact through functional imaging. Though PET images provide the functional information about the human organs, they are hard to interpret because of the lack of anatomical information. Our objective is to develop a knowledge-based biomedical image analysis system which can interpret the anatomical images (such as CT). The anatomical information thus obtained can then be used in analyzing PET images of the same patient. This will not only help in interpreting PET images but it will also provide a means of studying the correlation between the anatomical and functional imaging. This paper presents the preliminary results of the knowledge based biomedical image analysis system for interpreting CT images of the chest.

  18. On 3-D inelastic analysis methods for hot section components. Volume 1: Special finite element models

    NASA Technical Reports Server (NTRS)

    Nakazawa, S.

    1987-01-01

    This Annual Status Report presents the results of work performed during the third year of the 3-D Inelastic Analysis Methods for Hot Section Components program (NASA Contract NAS3-23697). The objective of the program is to produce a series of new computer codes that permit more accurate and efficient three-dimensional analysis of selected hot section components, i.e., combustor liners, turbine blades, and turbine vanes. The computer codes embody a progression of mathematical models and are streamlined to take advantage of geometrical features, loading conditions, and forms of material response that distinguish each group of selected components. This report is presented in two volumes. Volume 1 describes effort performed under Task 4B, Special Finite Element Special Function Models, while Volume 2 concentrates on Task 4C, Advanced Special Functions Models.

  19. The Use of Atomic Force Microscopy for 3D Analysis of Nucleic Acid Hybridization on Microarrays.

    PubMed

    Dubrovin, E V; Presnova, G V; Rubtsova, M Yu; Egorov, A M; Grigorenko, V G; Yaminsky, I V

    2015-01-01

    Oligonucleotide microarrays are considered today to be one of the most efficient methods of gene diagnostics. The capability of atomic force microscopy (AFM) to characterize the three-dimensional morphology of single molecules on a surface allows one to use it as an effective tool for the 3D analysis of a microarray for the detection of nucleic acids. The high resolution of AFM offers ways to decrease the detection threshold of target DNA and increase the signal-to-noise ratio. In this work, we suggest an approach to the evaluation of the results of hybridization of gold nanoparticle-labeled nucleic acids on silicon microarrays based on an AFM analysis of the surface both in air and in liquid which takes into account of their three-dimensional structure. We suggest a quantitative measure of the hybridization results which is based on the fraction of the surface area occupied by the nanoparticles.

  20. Multi-resolution entropy analysis of gait symmetry in neurological degenerative diseases and amyotrophic lateral sclerosis.

    PubMed

    Liao, Fuyuan; Wang, Jue; He, Ping

    2008-04-01

    Gait rhythm of patients with Parkinson's disease (PD), Huntington's disease (HD) and amyotrophic lateral sclerosis (ALS) has been studied focusing on the fractal and correlation properties of stride time fluctuations. In this study, we investigated gait asymmetry in these diseases using the multi-resolution entropy analysis of stance time fluctuations. Since stance time is likely to exhibit fluctuations across multiple spatial and temporal scales, the data series were decomposed into appropriate levels by applying stationary wavelet transform. The similarity between two corresponding wavelet coefficient series in terms of their regularities at each level was quantified based on a modified sample entropy method and a weighted sum was then used as gait symmetry index. We found that gait symmetry in subjects with PD and HD, especially with ALS is significantly disturbed. This method may be useful in characterizing certain pathologies of motor control and, possibly, in monitoring disease progression and evaluating the effect of an individual treatment.

  1. Automated extraction and analysis of rock discontinuity characteristics from 3D point clouds

    NASA Astrophysics Data System (ADS)

    Bianchetti, Matteo; Villa, Alberto; Agliardi, Federico; Crosta, Giovanni B.

    2016-04-01

    A reliable characterization of fractured rock masses requires an exhaustive geometrical description of discontinuities, including orientation, spacing, and size. These are required to describe discontinuum rock mass structure, perform Discrete Fracture Network and DEM modelling, or provide input for rock mass classification or equivalent continuum estimate of rock mass properties. Although several advanced methodologies have been developed in the last decades, a complete characterization of discontinuity geometry in practice is still challenging, due to scale-dependent variability of fracture patterns and difficult accessibility to large outcrops. Recent advances in remote survey techniques, such as terrestrial laser scanning and digital photogrammetry, allow a fast and accurate acquisition of dense 3D point clouds, which promoted the development of several semi-automatic approaches to extract discontinuity features. Nevertheless, these often need user supervision on algorithm parameters which can be difficult to assess. To overcome this problem, we developed an original Matlab tool, allowing fast, fully automatic extraction and analysis of discontinuity features with no requirements on point cloud accuracy, density and homogeneity. The tool consists of a set of algorithms which: (i) process raw 3D point clouds, (ii) automatically characterize discontinuity sets, (iii) identify individual discontinuity surfaces, and (iv) analyse their spacing and persistence. The tool operates in either a supervised or unsupervised mode, starting from an automatic preliminary exploration data analysis. The identification and geometrical characterization of discontinuity features is divided in steps. First, coplanar surfaces are identified in the whole point cloud using K-Nearest Neighbor and Principal Component Analysis algorithms optimized on point cloud accuracy and specified typical facet size. Then, discontinuity set orientation is calculated using Kernel Density Estimation and

  2. 3D tract-specific local and global analysis of white matter integrity in Alzheimer's disease.

    PubMed

    Jin, Yan; Huang, Chao; Daianu, Madelaine; Zhan, Liang; Dennis, Emily L; Reid, Robert I; Jack, Clifford R; Zhu, Hongtu; Thompson, Paul M

    2017-03-01

    Alzheimer's disease (AD) is a chronic neurodegenerative disease characterized by progressive decline in memory and other aspects of cognitive function. Diffusion-weighted imaging (DWI) offers a non-invasive approach to delineate the effects of AD on white matter (WM) integrity. Previous studies calculated either some summary statistics over regions of interest (ROI analysis) or some statistics along mean skeleton lines (Tract Based Spatial Statistic [TBSS]), so they cannot quantify subtle local WM alterations along major tracts. Here, a comprehensive WM analysis framework to map disease effects on 3D tracts both locally and globally, based on a study of 200 subjects: 49 healthy elderly normal controls, 110 with mild cognitive impairment, and 41 AD patients has been presented. 18 major WM tracts were extracted with our automated clustering algorithm-autoMATE (automated Multi-Atlas Tract Extraction); we then extracted multiple DWI-derived parameters of WM integrity along the WM tracts across all subjects. A novel statistical functional analysis method-FADTTS (Functional Analysis for Diffusion Tensor Tract Statistics) was applied to quantify degenerative patterns along WM tracts across different stages of AD. Gradually increasing WM alterations were found in all tracts in successive stages of AD. Among all 18 WM tracts, the fornix was most adversely affected. Among all the parameters, mean diffusivity (MD) was the most sensitive to WM alterations in AD. This study provides a systematic workflow to examine WM integrity across automatically computed 3D tracts in AD and may be useful in studying other neurological and psychiatric disorders. Hum Brain Mapp 38:1191-1207, 2017. © 2016 Wiley Periodicals, Inc.

  3. 3D tract‐specific local and global analysis of white matter integrity in Alzheimer's disease

    PubMed Central

    Jin, Yan; Huang, Chao; Daianu, Madelaine; Zhan, Liang; Dennis, Emily L.; Reid, Robert I.; Jack, Clifford R.; Zhu, Hongtu

    2016-01-01

    Abstract Alzheimer's disease (AD) is a chronic neurodegenerative disease characterized by progressive decline in memory and other aspects of cognitive function. Diffusion‐weighted imaging (DWI) offers a non‐invasive approach to delineate the effects of AD on white matter (WM) integrity. Previous studies calculated either some summary statistics over regions of interest (ROI analysis) or some statistics along mean skeleton lines (Tract Based Spatial Statistic [TBSS]), so they cannot quantify subtle local WM alterations along major tracts. Here, a comprehensive WM analysis framework to map disease effects on 3D tracts both locally and globally, based on a study of 200 subjects: 49 healthy elderly normal controls, 110 with mild cognitive impairment, and 41 AD patients has been presented. 18 major WM tracts were extracted with our automated clustering algorithm—autoMATE (automated Multi‐Atlas Tract Extraction); we then extracted multiple DWI‐derived parameters of WM integrity along the WM tracts across all subjects. A novel statistical functional analysis method—FADTTS (Functional Analysis for Diffusion Tensor Tract Statistics) was applied to quantify degenerative patterns along WM tracts across different stages of AD. Gradually increasing WM alterations were found in all tracts in successive stages of AD. Among all 18 WM tracts, the fornix was most adversely affected. Among all the parameters, mean diffusivity (MD) was the most sensitive to WM alterations in AD. This study provides a systematic workflow to examine WM integrity across automatically computed 3D tracts in AD and may be useful in studying other neurological and psychiatric disorders. Hum Brain Mapp 38:1191–1207, 2017. © 2016 Wiley Periodicals, Inc. PMID:27883250

  4. Automatic segmentation and analysis of fibrin networks in 3D confocal microscopy images

    NASA Astrophysics Data System (ADS)

    Liu, Xiaomin; Mu, Jian; Machlus, Kellie R.; Wolberg, Alisa S.; Rosen, Elliot D.; Xu, Zhiliang; Alber, Mark S.; Chen, Danny Z.

    2012-02-01

    Fibrin networks are a major component of blood clots that provides structural support to the formation of growing clots. Abnormal fibrin networks that are too rigid or too unstable can promote cardiovascular problems and/or bleeding. However, current biological studies of fibrin networks rarely perform quantitative analysis of their structural properties (e.g., the density of branch points) due to the massive branching structures of the networks. In this paper, we present a new approach for segmenting and analyzing fibrin networks in 3D confocal microscopy images. We first identify the target fibrin network by applying the 3D region growing method with global thresholding. We then produce a one-voxel wide centerline for each fiber segment along which the branch points and other structural information of the network can be obtained. Branch points are identified by a novel approach based on the outer medial axis. Cells within the fibrin network are segmented by a new algorithm that combines cluster detection and surface reconstruction based on the α-shape approach. Our algorithm has been evaluated on computer phantom images of fibrin networks for identifying branch points. Experiments on z-stack images of different types of fibrin networks yielded results that are consistent with biological observations.

  5. SAFE-3D analysis of a piezoelectric transducer to excite guided waves in a rail web

    NASA Astrophysics Data System (ADS)

    Ramatlo, Dineo A.; Long, Craig S.; Loveday, Philip W.; Wilke, Daniel N.

    2016-02-01

    Our existing Ultrasonic Broken Rail Detection system detects complete breaks and primarily uses a propagating mode with energy concentrated in the head of the rail. Previous experimental studies have demonstrated that a mode with energy concentrated in the head of the rail, is capable of detecting weld reflections at long distances. Exploiting a mode with energy concentrated in the web of the rail would allow us to effectively detect defects in the web of the rail and could also help to distinguish between reflections from welds and cracks. In this paper, we will demonstrate the analysis of a piezoelectric transducer attached to the rail web. The forced response at different frequencies is computed by the Semi-Analytical Finite Element (SAFE) method and compared to a full three-dimensional finite element method using ABAQUS. The SAFE method only requires the rail track cross-section to be meshed using two-dimensional elements. The ABAQUS model in turn requires a full three-dimensional discretisation of the rail track. The SAFE approach can yield poor predictions at cut-on frequencies associated with other modes in the rail. Problematic frequencies are identified and a suitable frequency range identified for transducer design. The forced response results of the two methods were found to be in good agreement with each other. We then use a previously developed SAFE-3D method to analyse a practical transducer over the selected frequency range. The results obtained from the SAFE-3D method are in good agreement with experimental measurements.

  6. Comparative 3D genome structure analysis of the fission and the budding yeast.

    PubMed

    Gong, Ke; Tjong, Harianto; Zhou, Xianghong Jasmine; Alber, Frank

    2015-01-01

    We studied the 3D structural organization of the fission yeast genome, which emerges from the tethering of heterochromatic regions in otherwise randomly configured chromosomes represented as flexible polymer chains in an nuclear environment. This model is sufficient to explain in a statistical manner many experimentally determined distinctive features of the fission yeast genome, including chromatin interaction patterns from Hi-C experiments and the co-locations of functionally related and co-expressed genes, such as genes expressed by Pol-III. Our findings demonstrate that some previously described structure-function correlations can be explained as a consequence of random chromatin collisions driven by a few geometric constraints (mainly due to centromere-SPB and telomere-NE tethering) combined with the specific gene locations in the chromosome sequence. We also performed a comparative analysis between the fission and budding yeast genome structures, for which we previously detected a similar organizing principle. However, due to the different chromosome sizes and numbers, substantial differences are observed in the 3D structural genome organization between the two species, most notably in the nuclear locations of orthologous genes, and the extent of nuclear territories for genes and chromosomes. However, despite those differences, remarkably, functional similarities are maintained, which is evident when comparing spatial clustering of functionally related genes in both yeasts. Functionally related genes show a similar spatial clustering behavior in both yeasts, even though their nuclear locations are largely different between the yeast species.

  7. Multispectral polarization viewing angle analysis of circular polarized stereoscopic 3D displays

    NASA Astrophysics Data System (ADS)

    Boher, Pierre; Leroux, Thierry; Bignon, Thibault; Collomb-Patton, Véronique

    2010-02-01

    In this paper we propose a method to characterize polarization based stereoscopic 3D displays using multispectral Fourier optics viewing angle measurements. Full polarization analysis of the light emitted by the display in the full viewing cone is made at 31 wavelengths in the visible range. Vertical modulation of the polarization state is observed and explained by the position of the phase shift filter into the display structure. In addition, strong spectral dependence of the ellipticity and polarization degree is observed. These features come from the strong spectral dependence of the phase shift film and introduce some imperfections (color shifts and reduced contrast). Using the measured transmission properties of the two glasses filters, the resulting luminance across each filter is computed for left and right eye views. Monocular contrast for each eye and binocular contrasts are performed in the observer space, and Qualified Monocular and Binocular Viewing Spaces (QMVS and QBVS) can be deduced in the same way as auto-stereoscopic 3D displays allowing direct comparison of the performances.

  8. Novel 3D/VR interactive environment for MD simulations, visualization and analysis.

    PubMed

    Doblack, Benjamin N; Allis, Tim; Dávila, Lilian P

    2014-12-18

    The increasing development of computing (hardware and software) in the last decades has impacted scientific research in many fields including materials science, biology, chemistry and physics among many others. A new computational system for the accurate and fast simulation and 3D/VR visualization of nanostructures is presented here, using the open-source molecular dynamics (MD) computer program LAMMPS. This alternative computational method uses modern graphics processors, NVIDIA CUDA technology and specialized scientific codes to overcome processing speed barriers common to traditional computing methods. In conjunction with a virtual reality system used to model materials, this enhancement allows the addition of accelerated MD simulation capability. The motivation is to provide a novel research environment which simultaneously allows visualization, simulation, modeling and analysis. The research goal is to investigate the structure and properties of inorganic nanostructures (e.g., silica glass nanosprings) under different conditions using this innovative computational system. The work presented outlines a description of the 3D/VR Visualization System and basic components, an overview of important considerations such as the physical environment, details on the setup and use of the novel system, a general procedure for the accelerated MD enhancement, technical information, and relevant remarks. The impact of this work is the creation of a unique computational system combining nanoscale materials simulation, visualization and interactivity in a virtual environment, which is both a research and teaching instrument at UC Merced.

  9. Novel 3D/VR Interactive Environment for MD Simulations, Visualization and Analysis

    PubMed Central

    Doblack, Benjamin N.; Allis, Tim; Dávila, Lilian P.

    2014-01-01

    The increasing development of computing (hardware and software) in the last decades has impacted scientific research in many fields including materials science, biology, chemistry and physics among many others. A new computational system for the accurate and fast simulation and 3D/VR visualization of nanostructures is presented here, using the open-source molecular dynamics (MD) computer program LAMMPS. This alternative computational method uses modern graphics processors, NVIDIA CUDA technology and specialized scientific codes to overcome processing speed barriers common to traditional computing methods. In conjunction with a virtual reality system used to model materials, this enhancement allows the addition of accelerated MD simulation capability. The motivation is to provide a novel research environment which simultaneously allows visualization, simulation, modeling and analysis. The research goal is to investigate the structure and properties of inorganic nanostructures (e.g., silica glass nanosprings) under different conditions using this innovative computational system. The work presented outlines a description of the 3D/VR Visualization System and basic components, an overview of important considerations such as the physical environment, details on the setup and use of the novel system, a general procedure for the accelerated MD enhancement, technical information, and relevant remarks. The impact of this work is the creation of a unique computational system combining nanoscale materials simulation, visualization and interactivity in a virtual environment, which is both a research and teaching instrument at UC Merced. PMID:25549300

  10. 3D Analysis of Porosity in a Ceramic Coating Using X-ray Microscopy

    NASA Astrophysics Data System (ADS)

    Klement, Uta; Ekberg, Johanna; Kelly, Stephen T.

    2017-02-01

    Suspension plasma spraying (SPS) is a new, innovative plasma spray technique using a feedstock consisting of fine powder particles suspended in a liquid. Using SPS, ceramic coatings with columnar microstructures have been produced which are used as topcoats in thermal barrier coatings. The microstructure contains a wide pore size range consisting of inter-columnar spacings, micro-pores and nano-pores. Hence, determination of total porosity and pore size distribution is a challenge. Here, x-ray microscopy (XRM) has been applied for describing the complex pore space of the coatings because of its capability to image the (local) porosity within the coating in 3D at a resolution down to 50 nm. The possibility to quantitatively segment the analyzed volume allows analysis of both open and closed porosity. For an yttria-stabilized zirconia coating with feathery microstructure, both open and closed porosity were determined and it could be revealed that 11% of the pore volumes (1.4% of the total volume) are closed pores. The analyzed volume was reconstructed to illustrate the distribution of open and closed pores in 3D. Moreover, pore widths and pore volumes were determined. The results on the complex pore space obtained by XRM are discussed in connection with other porosimetry techniques.

  11. Laser Scanning for 3D Object Characterization: Infrastructure for Exploration and Analysis of Vegetation Signatures

    NASA Astrophysics Data System (ADS)

    Koenig, K.; Höfle, B.

    2012-04-01

    Mapping and characterization of the three-dimensional nature of vegetation is increasingly gaining in importance. Deeper insight is required for e.g. forest management, biodiversity assessment, habitat analysis, precision agriculture, renewable energy production or the analysis of interaction between biosphere and atmosphere. However the potential of 3D vegetation characterization has not been exploited so far and new technologies are needed. Laser scanning has evolved into the state-of-the-art technology for highly accurate 3D data acquisition. By now several studies indicated a high value of 3D vegetation description by using laser data. The laser sensors provide a detailed geometric presentation (geometric information) of scanned objects as well as a full profile of laser energy that was scattered back to the sensor (radiometric information). In order to exploit the full potential of these datasets, profound knowledge on laser scanning technology for data acquisition, geoinformation technology for data analysis and object of interest (e.g. vegetation) for data interpretation have to be joined. A signature database is a collection of signatures of reference vegetation objects acquired under known conditions and sensor parameters and can be used to improve information extraction from unclassified vegetation datasets. Different vegetation elements (leaves, branches, etc.) at different heights above ground with different geometric composition contribute to the overall description (i.e. signature) of the scanned object. The developed tools allow analyzing tree objects according to single features (e.g. echo width and signal amplitude) and to any relation of features and derived statistical values (e.g. ratio of laser point attributes). For example, a single backscatter cross section value does not allow for tree species determination, whereas the average echo width per tree segment can give good estimates. Statistical values and/or distributions (e.g. Gaussian

  12. 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events

    NASA Technical Reports Server (NTRS)

    Brown, Richard; Navard, Andrew; Spruce, Joseph

    2010-01-01

    An analytical, advanced imaging method has been developed for the initial monitoring and identification of foam debris and similar anomalies that occur post-launch in reference to the space shuttle s external tank (ET). Remote sensing technologies have been used to perform image enhancement and analysis on high-resolution, true-color images collected with the DCS 760 Kodak digital camera located in the right umbilical well of the space shuttle. Improvements to the camera, using filters, have added sharpness/definition to the image sets; however, image review/analysis of the ET has been limited by the fact that the images acquired by umbilical cameras during launch are two-dimensional, and are usually nonreferenceable between frames due to rotation translation of the ET as it falls away from the space shuttle. Use of stereo pairs of these images can enable strong visual indicators that can immediately portray depth perception of damaged areas or movement of fragments between frames is not perceivable in two-dimensional images. A stereoscopic image visualization system has been developed to allow 3D depth perception of stereo-aligned image pairs taken from in-flight umbilical and handheld digital shuttle cameras. This new system has been developed to augment and optimize existing 2D monitoring capabilities. Using this system, candidate sequential image pairs are identified for transformation into stereo viewing pairs. Image orientation is corrected using control points (similar points) between frames to place the two images in proper X-Y viewing perspective. The images are then imported into the WallView stereo viewing software package. The collected control points are used to generate a transformation equation that is used to re-project one image and effectively co-register it to the other image. The co-registered, oriented image pairs are imported into a WallView image set and are used as a 3D stereo analysis slide show. Multiple sequential image pairs can be used

  13. The evolution of clinical gait analysis part III--kinetics and energy assessment.

    PubMed

    Sutherland, D H

    2005-06-01

    Historically, clinical applications of measurements of force and energy followed electromyography and kinematics in temporal sequence. This sequence is mirrored by the order of topics included in this trilogy on the Evolution of Clinical Gait Analysis, with part I [Sutherland DH. The evolution of clinical gait analysis part I: kinesiological EMG. Gait Posture 2001;14:61-70.] devoted to Kinesiological EMG and part II [Sutherland DH. The evolution of clinical gait analysis part II - kinematics. Gait Posture 2002;16(2):159-179.] to Kinematics. This final review in the series will focus on kinetics as it relates to gait applications. Kinematic measurements give the movements of the body segments, which can be compared with normal controls to identify pathological gait patterns, but they do not deal with the forces controlling the movements. As a major goal of scientifically minded clinicians is to understand the biomechanical forces producing movements, the objective measurement of ground reaction forces is essential. The force plate (platform) is now an indispensable tool in a state-of-the-art motion analysis laboratory. Nonetheless, it is not a stand-alone instrument as both kinematic and EMG measurements are needed for maximum clinical implementation and interpretation of force plate measurements. The subject of energy assessment is also given mention, as there is a compelling interest in whether walking has been made easier with intervention. The goals of this manuscript are to provide a historical background, recognize some of the important contributors, and describe the current multiple uses of the force plate in gait analysis. The widespread use of force plates for postural analyses is an important and more recent application of this technology, but this review will be restricted to measurements of gait rather than balance activities. Finally, this manuscript presents my personal perspective and discusses the developments and contributors that have shaped my

  14. 3D texture analysis of solitary pulmonary nodules using co-occurrence matrix from volumetric lung CT images

    NASA Astrophysics Data System (ADS)

    Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Khandelwal, Niranjan

    2013-02-01

    In this paper we have investigated a new approach for texture features extraction using co-occurrence matrix from volumetric lung CT image. Traditionally texture analysis is performed in 2D and is suitable for images collected from 2D imaging modality. The use of 3D imaging modalities provide the scope of texture analysis from 3D object and 3D texture feature are more realistic to represent 3D object. In this work, Haralick's texture features are extended in 3D and computed from volumetric data considering 26 neighbors. The optimal texture features to characterize the internal structure of Solitary Pulmonary Nodules (SPN) are selected based on area under curve (AUC) values of ROC curve and p values from 2-tailed Student's t-test. The selected texture feature in 3D to represent SPN can be used in efficient Computer Aided Diagnostic (CAD) design plays an important role in fast and accurate lung cancer screening. The reduced number of input features to the CAD system will decrease the computational time and classification errors caused by irrelevant features. In the present work, SPN are classified from Ground Glass Nodule (GGN) using Artificial Neural Network (ANN) classifier considering top five 3D texture features and top five 2D texture features separately. The classification is performed on 92 SPN and 25 GGN from Imaging Database Resources Initiative (IDRI) public database and classification accuracy using 3D texture features and 2D texture features provide 97.17% and 89.1% respectively.

  15. A non linear analysis of human gait time series based on multifractal analysis and cross correlations

    NASA Astrophysics Data System (ADS)

    Muñoz-Diosdado, A.

    2005-01-01

    We analyzed databases with gait time series of adults and persons with Parkinson, Huntington and amyotrophic lateral sclerosis (ALS) diseases. We obtained the staircase graphs of accumulated events that can be bounded by a straight line whose slope can be used to distinguish between gait time series from healthy and ill persons. The global Hurst exponent of these series do not show tendencies, we intend that this is because some gait time series have monofractal behavior and others have multifractal behavior so they cannot be characterized with a single Hurst exponent. We calculated the multifractal spectra, obtained the spectra width and found that the spectra of the healthy young persons are almost monofractal. The spectra of ill persons are wider than the spectra of healthy persons. In opposition to the interbeat time series where the pathology implies loss of multifractality, in the gait time series the multifractal behavior emerges with the pathology. Data were collected from healthy and ill subjects as they walked in a roughly circular path and they have sensors in both feet, so we have one time series for the left foot and other for the right foot. First, we analyzed these time series separately, and then we compared both results, with direct comparison and with a cross correlation analysis. We tried to find differences in both time series that can be used as indicators of equilibrium problems.

  16. Inlining 3d Reconstruction, Multi-Source Texture Mapping and Semantic Analysis Using Oblique Aerial Imagery

    NASA Astrophysics Data System (ADS)

    Frommholz, D.; Linkiewicz, M.; Poznanska, A. M.

    2016-06-01

    This paper proposes an in-line method for the simplified reconstruction of city buildings from nadir and oblique aerial images that at the same time are being used for multi-source texture mapping with minimal resampling. Further, the resulting unrectified texture atlases are analyzed for façade elements like windows to be reintegrated into the original 3D models. Tests on real-world data of Heligoland/ Germany comprising more than 800 buildings exposed a median positional deviation of 0.31 m at the façades compared to the cadastral map, a correctness of 67% for the detected windows and good visual quality when being rendered with GPU-based perspective correction. As part of the process building reconstruction takes the oriented input images and transforms them into dense point clouds by semi-global matching (SGM). The point sets undergo local RANSAC-based regression and topology analysis to detect adjacent planar surfaces and determine their semantics. Based on this information the roof, wall and ground surfaces found get intersected and limited in their extension to form a closed 3D building hull. For texture mapping the hull polygons are projected into each possible input bitmap to find suitable color sources regarding the coverage and resolution. Occlusions are detected by ray-casting a full-scale digital surface model (DSM) of the scene and stored in pixel-precise visibility maps. These maps are used to derive overlap statistics and radiometric adjustment coefficients to be applied when the visible image parts for each building polygon are being copied into a compact texture atlas without resampling whenever possible. The atlas bitmap is passed to a commercial object-based image analysis (OBIA) tool running a custom rule set to identify windows on the contained façade patches. Following multi-resolution segmentation and classification based on brightness and contrast differences potential window objects are evaluated against geometric constraints and

  17. 3D Plasma Clusters: Analysis of dynamical evolution and individual particle interaction

    SciTech Connect

    Antonova, T.; Thomas, H. M.; Morfill, G. E.; Annaratone, B. M.

    2008-09-07

    3D plasma clusters (up to 100 particles) have been built inside small (32 mm{sup 3}) plasma volume in gravity. It has been estimated that the external confinement has a negligible influence on the processes inside the clusters. At such conditions the analysis of dynamical evolution and individual particle interactions have shown that the binary interaction among particles in addition to the repelling Coulomb force exhibits also an attractive part. The tendency of the systems to approach the state with minimum energy by rearranging particles inside has been detected. The measured 63 particles' cluster vibrations are in close agreement with vibrations of a drop with surface tension. This indicates that even a 63 particle cluster already exhibits properties normally associated with the cooperative regime.

  18. 3D thermal analysis of rectangular microscale inorganic light-emitting diodes in a pulsed operation

    NASA Astrophysics Data System (ADS)

    Cui, Y.; Bian, Z.; Li, Y.; Xing, Y.; Song, J.

    2016-10-01

    Microscale inorganic light-emitting diodes (µ-ILEDs) have attracted much attention due to their excellent performance in biointegrated applications such as optogenetics. The thermal behaviors of µ-ILEDs are critically important since a certain temperature increase may degrade the LED performance and cause tissue lesion. The µ-ILEDs in a pulsed operation offer an advantage in thermal management. In this paper, a 3D analytic model, as validated by finite element analysis, is developed to study the thermal response of rectangular µ-ILEDs in a pulsed operation. A scaling law for the maximum normalized temperature increase of rectangular µ-ILEDs in terms of non-dimensional parameters is established. The influences of geometric (i.e. shape factor) and loading parameters (e.g. duty cycle and period) on the temperature increase are systematically investigated. These results are very helpful in designing µ-ILEDs by providing guidelines to avoid adverse thermal effects.

  19. Lightning strike simulation using coaxial line technique and 3D linear injection current analysis

    NASA Astrophysics Data System (ADS)

    Flourens, F.; Gauthier, D.; Serafin, D.

    1989-09-01

    The GORFFD code for determining aircraft responses to either a lightning event or to simulated current injection is based on the finite-difference solution of Maxwell's equation, and allows the simulation of complex, 3D metallic and dielectric composite structures. A transfer method is used to analyze the EM environment associated with in-flight measurements. Attention is given to a linear-analysis numerical model in which the lightning channel is simulated as a thin wire that is driven by a current source. Surface E-fields and current mappings are produced for the Transall transport and Mirage fighter aircraft. An experimental method has been devised for verification of these lightning-strike simulations.

  20. The 3D EdgeRunner Pipeline: a novel shape-based analysis for neoplasms characterization

    NASA Astrophysics Data System (ADS)

    Yepes-C, Fernando; Johnson, Rebecca; Lao, Yi; Hwang, Darryl; Coloigner, Julie; Yap, Felix; Bushan, Desai; Cheng, Phillip; Gill, Inderbir; Duddalwar, Vinay; Lepore, Natasha

    2016-03-01

    The characterization of tumors after being imaged is currently a qualitative process performed by skilled professionals. If we can aid their diagnosis by identifying quantifiable features associated with tumor classification, we may avoid invasive procedures such as biopsies and enhance efficiency. The aim of this paper is to describe the 3D EdgeRunner Pipeline which characterizes the shape of a tumor. Shape analysis is relevant as malignant tumors tend to be more lobular and benign ones tare generally more symmetrical. The method described considers the distance from each point on the edge of the tumor to the centre of a synthetically created field of view. The method then determines coordinates where the measured distances are rapidly changing (peaks) using a second derivative found by five point differentiation. The list of coordinates considered to be peaks can then be used as statistical data to compare tumors quantitatively. We have found this process effectively captures the peaks on a selection of kidney tumors.

  1. A 3-D Magnetic Analysis of a Linear Alternator For a Stirling Power System

    NASA Technical Reports Server (NTRS)

    Geng, Steven M.; Schwarze, Gene E.; Niedra, Janis M.

    2000-01-01

    The NASA Glenn Research Center and the Department of Energy (DOE) are developing advanced radioisotope Stirling convertors, under contract with Stirling Technology Company (STC), for space applications. Of critical importance to the successful development of the Stirling convertor for space power applications is the development of a lightweight and highly efficient linear alternator. This paper presents a 3-D finite element method (FEM) approach for evaluating Stirling convertor linear alternators. Preliminary correlations with open-circuit voltage measurements provide an encouraging level of confidence in the model. Spatial plots of magnetic field strength (H) are presented in the region of the exciting permanent magnets. These plots identify regions of high H, where at elevated temperature and under electrical load, the potential to alter the magnetic moment of the magnets exists. This implies the need for further testing and analysis.

  2. [Upper airway's 3D analysis of patients with obstructive sleep apnea using tomographic cone beam].

    PubMed

    Bruwier, A; Poirrier, A L; Limme, M; Poirrier, R

    2014-12-01

    The progress of medical imaging over the last decades has led to a better understanding of the upper airway structure in sleep-disordered patients. The Obstructive Sleep Apnea Syndrome (OSA) is attributed to a functional narrowing of the upper airway, particularly of the oropharynx, during sleep. This narrowing is multifactorial. We have shown that in 60% cases, the maxilla (nasal pyramid) seems too narrow. A mandible retroposition may also play a dominant role in 30% of the cases. Both scenarios can be combined. Cone Beam Computed Tomography (CBCT) is a new medical imaging technique that permits to visualize the upper airway with less ionizing radiation than the conventional scanner. To date, only five authors have performed an upper airway's 3D analysis of sleep apnea patients with cone beam. A better understanding of the affected segment of the upper airway should help refine treatment options.

  3. In-chip fabrication of free-form 3D constructs for directed cell migration analysis.

    PubMed

    Olsen, Mark Holm; Hjortø, Gertrud Malene; Hansen, Morten; Met, Özcan; Svane, Inge Marie; Larsen, Niels B

    2013-12-21

    Free-form constructs with three-dimensional (3D) microporosity were fabricated by two-photon polymerization inside the closed microchannel of an injection-molded, commercially available polymer chip for analysis of directed cell migration. Acrylate constructs were produced as woodpile topologies with a range of pore sizes from 5 × 5 μm to 15 × 15 μm and prefilled with fibrillar collagen. Dendritic cells seeded into the polymer chip in a concentration gradient of the chemoattractant CCL21 efficiently negotiated the microporous maze structure for pore sizes of 8 × 8 μm or larger. The cells migrating through smaller pore sizes made significantly more turns than those through larger pores. The introduction of additional defined barriers in the microporous structure resulted in dendritic cells making more turns while still being able to follow the chemoattractant concentration gradient.

  4. Quantitative 3D analysis of complex single border cell behaviors in coordinated collective cell migration.

    PubMed

    Cliffe, Adam; Doupé, David P; Sung, HsinHo; Lim, Isaac Kok Hwee; Ong, Kok Haur; Cheng, Li; Yu, Weimiao

    2017-04-04

    Understanding the mechanisms of collective cell migration is crucial for cancer metastasis, wound healing and many developmental processes. Imaging a migrating cluster in vivo is feasible, but the quantification of individual cell behaviours remains challenging. We have developed an image analysis toolkit, CCMToolKit, to quantify the Drosophila border cell system. In addition to chaotic motion, previous studies reported that the migrating cells are able to migrate in a highly coordinated pattern. We quantify the rotating and running migration modes in 3D while also observing a range of intermediate behaviours. Running mode is driven by cluster external protrusions. Rotating mode is associated with cluster internal cell extensions that could not be easily characterized. Although the cluster moves slower while rotating, individual cells retain their mobility and are in fact slightly more active than in running mode. We also show that individual cells may exchange positions during migration.

  5. Noise analysis for near field 3-D FM-CW radar imaging systems

    SciTech Connect

    Sheen, David M.

    2015-06-19

    Near field radar imaging systems are used for several applications including concealed weapon detection in airports and other high-security venues. Despite the near-field operation, phase noise and thermal noise can limit the performance in several ways including reduction in system sensitivity and reduction of image dynamic range. In this paper, the effects of thermal noise, phase noise, and processing gain are analyzed in the context of a near field 3-D FM-CW imaging radar as might be used for concealed weapon detection. In addition to traditional frequency domain analysis, a time-domain simulation is employed to graphically demonstrate the effect of these noise sources on a fast-chirping FM-CW system.

  6. Analysis of Composite Panel-Stiffener Debonding Using a Shell/3D Modeling Technique

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; Minguet, Pierre J.

    2006-01-01

    Interlaminar fracture mechanics has proven useful for characterizing the onset of delaminations in composites and has been used with limited success primarily to investigate onset in fracture toughness specimens and laboratory size coupon type specimens. Future acceptance of the methodology by industry and certification authorities however, requires the successful demonstration of the methodology on structural level. For this purpose a panel was selected that was reinforced with stringers. Shear loading cases the panel to buckle and the resulting out-of-plane deformations initiate skin/stringer separation at the location of an embedded defect. For finite element analysis, the panel and surrounding load fixture were modeled with shell element. A small section of the stringer foot and the panel in the vicinity of the embedded defect were modeled with a local 3D solid model. A failure index was calculated by correlating computed mixed-mode failure criterion of the graphite/epoxy material.

  7. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    PubMed

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment.

  8. A multiscale 3D finite element analysis of fluid/solute transport in mechanically loaded bone.

    PubMed

    Fan, Lixia; Pei, Shaopeng; Lucas Lu, X; Wang, Liyun

    2016-01-01

    The transport of fluid, nutrients, and signaling molecules in the bone lacunar-canalicular system (LCS) is critical for osteocyte survival and function. We have applied the fluorescence recovery after photobleaching (FRAP) approach to quantify load-induced fluid and solute transport in the LCS in situ, but the measurements were limited to cortical regions 30-50 μm underneath the periosteum due to the constrains of laser penetration. With this work, we aimed to expand our understanding of load-induced fluid and solute transport in both trabecular and cortical bone using a multiscaled image-based finite element analysis (FEA) approach. An intact murine tibia was first re-constructed from microCT images into a three-dimensional (3D) linear elastic FEA model, and the matrix deformations at various locations were calculated under axial loading. A segment of the above 3D model was then imported to the biphasic poroelasticity analysis platform (FEBio) to predict load-induced fluid pressure fields, and interstitial solute/fluid flows through LCS in both cortical and trabecular regions. Further, secondary flow effects such as the shear stress and/or drag force acting on osteocytes, the presumed mechano-sensors in bone, were derived using the previously developed ultrastructural model of Brinkman flow in the canaliculi. The material properties assumed in the FEA models were validated against previously obtained strain and FRAP transport data measured on the cortical cortex. Our results demonstrated the feasibility of this computational approach in estimating the fluid flux in the LCS and the cellular stimulation forces (shear and drag forces) for osteocytes in any cortical and trabecular bone locations, allowing further studies of how the activation of osteocytes correlates with in vivo functional bone formation. The study provides a promising platform to reveal potential cellular mechanisms underlying the anabolic power of exercises and physical activities in treating

  9. Thoracic Cavity Definition for 3D PET/CT Analysis and Visualization

    PubMed Central

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2015-01-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical detail on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage = 99.2% and leakage = 0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. PMID:25957746

  10. A multiscale 3D finite element analysis of fluid/solute transport in mechanically loaded bone

    PubMed Central

    Fan, Lixia; Pei, Shaopeng; Lucas Lu, X; Wang, Liyun

    2016-01-01

    The transport of fluid, nutrients, and signaling molecules in the bone lacunar–canalicular system (LCS) is critical for osteocyte survival and function. We have applied the fluorescence recovery after photobleaching (FRAP) approach to quantify load-induced fluid and solute transport in the LCS in situ, but the measurements were limited to cortical regions 30–50 μm underneath the periosteum due to the constrains of laser penetration. With this work, we aimed to expand our understanding of load-induced fluid and solute transport in both trabecular and cortical bone using a multiscaled image-based finite element analysis (FEA) approach. An intact murine tibia was first re-constructed from microCT images into a three-dimensional (3D) linear elastic FEA model, and the matrix deformations at various locations were calculated under axial loading. A segment of the above 3D model was then imported to the biphasic poroelasticity analysis platform (FEBio) to predict load-induced fluid pressure fields, and interstitial solute/fluid flows through LCS in both cortical and trabecular regions. Further, secondary flow effects such as the shear stress and/or drag force acting on osteocytes, the presumed mechano-sensors in bone, were derived using the previously developed ultrastructural model of Brinkman flow in the canaliculi. The material properties assumed in the FEA models were validated against previously obtained strain and FRAP transport data measured on the cortical cortex. Our results demonstrated the feasibility of this computational approach in estimating the fluid flux in the LCS and the cellular stimulation forces (shear and drag forces) for osteocytes in any cortical and trabecular bone locations, allowing further studies of how the activation of osteocytes correlates with in vivo functional bone formation. The study provides a promising platform to reveal potential cellular mechanisms underlying the anabolic power of exercises and physical activities in

  11. Analysis of trotter gait on the track by accelerometry and image analysis.

    PubMed

    Leleu, C; Gloria, E; Renault, G; Barrey, E

    2002-09-01

    The aim of this study was to describe the correlation between the phases of the limb cycle of trotters on the track and specific points on the acceleration curves obtained from a new gait analysis system. We compared kinematic data obtained by video image analysis and 3-dimensional acceleration recordings made on 3 French trotters in training. They trotted on a race track at speeds of 8.33, 10 and 11.66 m/s, with a final stretch at maximum speed. Their locomotion was recorded with a synchronised video camera at a frame frequency of 200 Hz and with the Equimétrix gait analysis system. The gait variables were calculated using 3-dimension acceleration data recorded at the sternum (dorso-ventral, longitudinal and lateral axes) at a sampling rate of 100 Hz. Three phases of the stride were clearly identified on the dorsoventral acceleration signal: hoof-landing, midstance phase and toe-off. Braking and propulsion phases were identified on the corresponding longitudinal acceleration signal. The weight-bearing diagonal was identified by observing the lateral signal. The stride temporal variables (stride, stance, braking and propulsion durations for both diagonals), measured by video analysis and by acceleration signal analysis, were not significantly different (P>0.05). The identification of specific points on the acceleration pattern allowed an accurate temporal analysis of the stride. Potential applications could be the determination of locomotor factors related to racing performance or assessment of locomotor disorders at high speed.

  12. 3D analysis of the reactivity insertion accident in VVER-1000

    SciTech Connect

    Abdullayev, A. M.; Zhukov, A. I.; Slyeptsov, S. M.

    2012-07-01

    Fuel parameters such as peak enthalpy and temperature during rod ejection accident are calculated. The calculations are performed by 3D neutron kinetics code NESTLE and 3D thermal-hydraulic code VIPRE-W. Both hot zero power and hot full power cases were studied for an equilibrium cycle with Westinghouse hex fuel in VVER-1000. It is shown that the use of 3D methodology can significantly increase safety margins for current criteria and met future criteria. (authors)

  13. The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units.

    PubMed

    Allseits, E; Lučarević, J; Gailey, R; Agrawal, V; Gaunaurd, I; Bennett, C

    2017-04-11

    The use of inertial measurement units (IMUs) for gait analysis has emerged as a tool for clinical applications. Shank gyroscope signals have been utilized to identify heel-strike and toe-off, which serve as the foundation for calculating temporal parameters of gait such as single and double limb support time. Recent publications have shown that toe-off occurs later than predicted by the dual minima method (DMM), which has been adopted as an IMU-based gait event detection algorithm.In this study, a real-time algorithm, Noise-Zero Crossing (NZC), was developed to accurately compute temporal gait parameters. Our objective was to determine the concurrent validity of temporal gait parameters derived from the NZC algorithm against parameters measured by an instrumented walkway. The accuracy and precision of temporal gait parameters derived using NZC were compared to those derived using the DMM. The results from Bland-Altman Analysis showed that the NZC algorithm had excellent agreement with the instrumented walkway for identifying the temporal gait parameters of Gait Cycle Time (GCT), Single Limb Support (SLS) time, and Double Limb Support (DLS) time. By utilizing the moment of zero shank angular velocity to identify toe-off, the NZC algorithm performed better than the DMM algorithm in measuring SLS and DLS times. Utilizing the NZC algorithm's gait event detection preserves DLS time, which has significant clinical implications for pathologic gait assessment.

  14. An integrated procedure for spine and full skeleton multi-sensor biomechanical analysis & averaging in posture gait and cyclic movement tasks.

    PubMed

    D'Amico, Moreno; D'Amico, Gabriele; Paniccia, Michele; Roncoletta, Piero; Vallasciani, Massimo

    2010-01-01

    Spine and posture disorders cover large interest in rehabilitation. Quantitative functional evaluation represents the main goal in Movement/Gait analysis. However very few studies outline the behaviour of spine during Posture and Movement/Gait analysis. To overcome such limits, several years ago our group started, a project to transfer into a complete fully 3D reliable and detailed representation, different segmental biomechanical models presented in literature. As result a complete 3D parametric biomechanical skeleton model has been developed to be used in quantitative analysis. Posture and Movement/Gait analysis are performed by 3D Opto-electronic stereophotogrammetric measurements of body landmarks labelled by passive markers. Depending on different analysis purposes, the model can work at different stages of complexity. Examples on the application of such model into biomechanical and clinical fields have been presented in literature. Our group is continuously working to add new features to such model, which is now able to fully integrate data deriving from force platforms, SEMG, foot pressure maps. By means of data fusion and optimisation procedures all these inputs are used in the model to assess lower limbs internal joint forces, torques and muscular efforts. The possibility to compute the average of cyclic or repetitive tasks has been included as well. Recently we added the possibility to assess internal joint forces and torques at each spine vertebral level and to correlate these latter with all the other model's features. The aim of this study is to present the methodological aspects of such new features and their potential applicability in clinical and biomechanical fields.

  15. surf3d: A 3-D finite-element program for the analysis of surface and corner cracks in solids subjected to mode-1 loadings

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Newman, J. C., Jr.

    1993-01-01

    A computer program, surf3d, that uses the 3D finite-element method to calculate the stress-intensity factors for surface, corner, and embedded cracks in finite-thickness plates with and without circular holes, was developed. The cracks are assumed to be either elliptic or part eliptic in shape. The computer program uses eight-noded hexahedral elements to model the solid. The program uses a skyline storage and solver. The stress-intensity factors are evaluated using the force method, the crack-opening displacement method, and the 3-D virtual crack closure methods. In the manual the input to and the output of the surf3d program are described. This manual also demonstrates the use of the program and describes the calculation of the stress-intensity factors. Several examples with sample data files are included with the manual. To facilitate modeling of the user's crack configuration and loading, a companion program (a preprocessor program) that generates the data for the surf3d called gensurf was also developed. The gensurf program is a three dimensional mesh generator program that requires minimal input and that builds a complete data file for surf3d. The program surf3d is operational on Unix machines such as CRAY Y-MP, CRAY-2, and Convex C-220.

  16. A Kinematic and Dynamic Analysis on Orthotic Gait of Paraplegics

    NASA Astrophysics Data System (ADS)

    Kagawa, Takahiro; Fukuda, Hiroshi; Uno, Yoji

    In this study, we address to quantify the relationship between the significant arm-clutch loading, leg restriction and motor paralysis, and analyze lumbar joint trajectories in the orthotic gait of paraplegic subjects and the ordinary and orthotic gaits of a normal subject using an inverted pendulum model. For the leg restriction, the trajectories are located in front of an equilibrium point of the inverted pendulum, and the loading is higher due to the influence of gravity moment. Comparing the trajectory of paraplegic and normal gait with orthosis in horizontal plane, the trajectory in the paraplegic subjects was rectilinear shape, while that in normal subject was curved in the direction to the equilibrium point. The loading is lower in the curved trajectory than in the straight trajectory because of the trade-off between gravity and inertia. These results suggest that the increase of the distance between the trunk movement and the equilibrium point of the inverted pendulum result in the significant loading due to the leg restriction and motor paralysis in orthotic gait of paraplegics.

  17. The Three-Dimensional (3D) Numerical Stability Analysis of Hyttemalmen Open-Pit

    NASA Astrophysics Data System (ADS)

    Cała, Marek; Kowalski, Michał; Stopkowicz, Agnieszka

    2014-10-01

    The purpose of this paper was to perform the 3D numerical calculations allowing slope stability analysis of Hyttemalmen open pit (location Kirkenes, Finnmark Province, Norway). After a ramp rock slide, which took place in December 2010, as well as some other small-scale rock slope stability problems, it proved necessary to perform a serious stability analyses. The Hyttemalmen open pit was designed with a depth up to 100 m, a bench height of 24 m and a ramp width of 10 m. The rock formation in the iron mining district of Kirkenes is called the Bjornevaten Group. This is the most structurally complicated area connected with tectonic process such as folding, faults and metamorphosis. The Bjornevaten Group is a volcano-sedimentary sequence. Rock slope stability depends on the mechanical properties of the rock, hydro-geological conditions, slope topography, joint set systems and seismic activity. However, rock slope stability is mainly connected with joint sets. Joints, or general discontinuities, are regarded as weak planes within rock which have strength reducing consequences with regard to rock strength. Discontinuities within the rock mass lead to very low tensile strength. Several simulations were performed utilising the RocLab (2007) software to estimate the gneiss cohesion for slopes of different height. The RocLab code is dedicated to estimate rock mass strength using the Hoek-Brown failure criterion. Utilising both the GSI index and the Hoek-Brown strength criterion the equivalent Mohr-Coulomb parameters (cohesion and angle of internal friction) can be calculated. The results of 3D numerical calculations (with FLA3D code) show that it is necessary to redesign the slope-bench system in the Hyttemalmen open pit. Changing slope inclination for lower stages is recommended. The minimum factor of safety should be equal 1.3. At the final planned stage of excavation, the factor of safety drops to 1.06 with failure surface ranging through all of the slopes. In the case

  18. Exploratory Analysis Of The 3D Cloud Resolving Model Simulations of TOGA COARE: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Mendes, S.; Bretherton, C.

    2007-12-01

    Global climate model studies suggest that cumulus momentum transport (CMT) in tropical oceanic convective cloud systems plays a significant role in the tropical mean circulation and transient variability. CMT is difficult to measure directly and can depend on the detailed structure and organization of the convection. Yet there have been comparatively few evaluations of CMT parameterizations and the assumptions underlying them using 3D cloud resolving model (CRM) simulations. We have analyzed CMT in a four month 3D 64x64x64 gridpoint CRM simulation of TOGA COARE with 1 km horizontal resolution. An additional 256x256x64 large-domain simulation was performed for a 10 day subperiod with strong convection combined with substantial mean vertical zonal wind shear, conditions favorably for strong CMT. Both simulations were identically forced with prescribed vertical motion, horizontal temperature and moisture advection, and relaxation of the domain-mean wind profile to observations on a one-hour timescale. Both were initialized with small amplitude white noise, but spun up realistic convection in less than a day. The domain-mean CMT in the small and large domain simulations for the 10-day common simulation period was compared. The two simulations showed remarkably similar CMT profiles on daily-mean timescales, suggesting that mesoscale contributions to CMT of scales greater than 64 km were small. The skill of a downgradient mixing-length parameterization CMT = Mc*L*DU/Dz was also tested. Here , Mc is convective mass flux, dU/dz is mean vertical shear, and L is a mixing length for updraft zonal velocity perturbations associated with entrainment and horizontal pressure gradient accelerations. This was done by regressing CMT at each height was regressed against Mc*DU/Dz at the same height across all 3D model snapshots over the 10 days. The correlation coefficient describes the accuracy of this downgradient parameterization, and L was calculated as the regression slope. In the

  19. Within-guild dietary discrimination from 3-D textural analysis of tooth microwear in insectivorous mammals

    PubMed Central

    Purnell, M A; Crumpton, N; Gill, P G; Jones, G; Rayfield, E J

    2013-01-01

    Resource exploitation and competition for food are important selective pressures in animal evolution. A number of recent investigations have focused on linkages between diversification, trophic morphology and diet in bats, partly because their roosting habits mean that for many bat species diet can be quantified relatively easily through faecal analysis. Dietary analysis in mammals is otherwise invasive, complicated, time consuming and expensive. Here we present evidence from insectivorous bats that analysis of three-dimensional (3-D) textures of tooth microwear using International Organization for Standardization (ISO) roughness parameters derived from sub-micron surface data provides an additional, powerful tool for investigation of trophic resource exploitation in mammals. Our approach, like scale-sensitive fractal analysis, offers considerable advantages over two-dimensional (2-D) methods of microwear analysis, including improvements in robustness, repeatability and comparability of studies. Our results constitute the first analysis of microwear textures in carnivorous mammals based on ISO roughness parameters. They demonstrate that the method is capable of dietary discrimination, even between cryptic species with subtly different diets within trophic guilds, and even when sample sizes are small. We find significant differences in microwear textures between insectivore species whose diet contains different proportions of ‘hard’ prey (such as beetles) and ‘soft’ prey (such as moths), and multivariate analyses are able to distinguish between species with different diets based solely on their tooth microwear textures. Our results show that, compared with previous 2-D analyses of microwear in bats, ISO roughness parameters provide a much more sophisticated characterization of the nature of microwear surfaces and can yield more robust and subtle dietary discrimination. ISO-based textural analysis of tooth microwear thus has a useful role to play

  20. Molecular Determinants of Juvenile Hormone Action as Revealed by 3D QSAR Analysis in Drosophila

    PubMed Central

    Beňo, Milan; Farkaš, Robert

    2009-01-01

    Background Postembryonic development, including metamorphosis, of many animals is under control of hormones. In Drosophila and other insects these developmental transitions are regulated by the coordinate action of two principal hormones, the steroid ecdysone and the sesquiterpenoid juvenile hormone (JH). While the mode of ecdysone action is relatively well understood, the molecular mode of JH action remains elusive. Methodology/Principal Findings To gain more insights into the molecular mechanism of JH action, we have tested the biological activity of 86 structurally diverse JH agonists in Drosophila melanogaster. The results were evaluated using 3D QSAR analyses involving CoMFA and CoMSIA procedures. Using this approach we have generated both computer-aided and species-specific pharmacophore fingerprints of JH and its agonists, which revealed that the most active compounds must possess an electronegative atom (oxygen or nitrogen) at both ends of the molecule. When either of these electronegative atoms are replaced by carbon or the distance between them is shorter than 11.5 Å or longer than 13.5 Å, their biological activity is dramatically decreased. The presence of an electron-deficient moiety in the middle of the JH agonist is also essential for high activity. Conclusions/Significance The information from 3D QSAR provides guidelines and mechanistic scope for identification of steric and electrostatic properties as well as donor and acceptor hydrogen-bonding that are important features of the ligand-binding cavity of a JH target protein. In order to refine the pharmacophore analysis and evaluate the outcomes of the CoMFA and CoMSIA study we used pseudoreceptor modeling software PrGen to generate a putative binding site surrogate that is composed of eight amino acid residues corresponding to the defined molecular interactions. PMID:19547707

  1. 3D linearized stability analysis of various forms of Burnett equations

    NASA Astrophysics Data System (ADS)

    Zhao, Wenwen; Chen, Weifang; Liu, Hualin; Agarwal, Ramesh K.

    2014-12-01

    Burnett equations were originally derived in 1935 by Burnett by employing the Chapman-Enskog expansion to Classical Boltzmann equation to second order in Knudsen number Kn. Since then several variants of these equations have been proposed in the literature; these variants have differing physical and numerical properties. In this paper, we consider three such variants which are known in the literature as `the Original Burnett (OB) equations', the Conventional Burnett (CB) equations' and the recently formulated by the authors `the Simplified Conventional (SCB) equations.' One of the most important issues in obtaining numerical solutions of the Burnett equations is their stability under small perturbations. In this paper, we perform the linearized stability (known as the Bobylev Stability) analysis of three-dimensional Burnett equations for all the three variants (OB, CB, and SCB) for the first time in the literature on this subject. By introducing small perturbations in the steady state flow field, the trajectory curve and the variation in attenuation coefficient with wave frequency of the characteristic equation are obtained for all the three variants of Burnett equations to determine their stability. The results show that the Simplified Conventional Burnett (SCB) equations are unconditionally stable under small wavelength perturbations. However, the Original Burnett (OB) and the Conventional Burnett (CB) equations are unstable when the Knudsen number becomes greater than a critical value and the stability condition worsens in 3D when compared to the stability condition for 1-D and 2-D equations. The critical Knudsen number for 3-D OB and CB equations is 0.061 and 0.287 respectively.

  2. Prospective in (Primate) Dental Analysis through Tooth 3D Topographical Quantification

    PubMed Central

    Guy, Franck; Gouvard, Florent; Boistel, Renaud; Euriat, Adelaïde; Lazzari, Vincent

    2013-01-01

    The occlusal morphology of the teeth is mostly determined by the enamel-dentine junction morphology; the enamel-dentine junction plays the role of a primer and conditions the formation of the occlusal enamel reliefs. However, the accretion of the enamel cap yields thickness variations that alter the morphology and the topography of the enamel–dentine junction (i.e., the differential deposition of enamel by the ameloblasts create an external surface that does not necessarily perfectly parallel the enamel–dentine junction). This self-reliant influence of the enamel on tooth morphology is poorly understood and still under-investigated. Studies considering the relationship between enamel and dentine morphologies are rare, and none of them tackled this relationship in a quantitative way. Major limitations arose from: (1) the difficulties to characterize the tooth morphology in its comprehensive tridimensional aspect and (2) practical issues in relating enamel and enamel–dentine junction quantitative traits. We present new aspects of form representation based exclusively on 3D analytical tools and procedures. Our method is applied to a set of 21 unworn upper second molars belonging to eight extant anthropoid genera. Using geometrical analysis of polygonal meshes representatives of the tooth form, we propose a 3D dataset that constitutes a detailed characterization of the enamel and of the enamel–dentine junction morphologies. Also, for the first time, to our knowledge, we intend to establish a quantitative method for comparing enamel and enamel–dentine junction surfaces descriptors (elevation, inclination, orientation, etc.). New indices that allow characterizing the occlusal morphology are proposed and discussed. In this note, we present technical aspects of our method with the example of anthropoid molars. First results show notable individual variations and taxonomic heterogeneities for the selected topographic parameters and for the pattern and strength of

  3. Femoral curvature in Neanderthals and modern humans: a 3D geometric morphometric analysis.

    PubMed

    De Groote, Isabelle

    2011-05-01

    Since their discovery, Neanderthals have been described as having a marked degree of anteroposterior curvature of the femoral shaft. Although initially believed to be pathological, subsequent discoveries of Neanderthal remains lead femoral curvature to be considered as a derived Neanderthal feature. A recent study on Neanderthals and middle and early Upper Palaeolithic modern humans found no differences in femoral curvature, but did not consider size-corrected curvature. Therefore, the objectives of this study were to use 3D morphometric landmark and semi-landmark analysis to quantify relative femoral curvature in Neanderthals, Upper Palaeolithic and recent modern humans, and to compare adult bone curvature as part of the overall femoral morphology among these populations. Comparisons among populations were made using geometric morphometrics (3D landmarks) and standard multivariate methods. Comparative material involved all available complete femora from Neanderthal and Upper Palaeolithic modern human, archaeological (Mesolithic, Neolithic, Medieval) and recent human populations representing a wide geographical and lifestyle range. There are significant differences in the anatomy of the femur between Neanderthals and modern humans. Neanderthals have more curved femora than modern humans. Early modern humans are most similar to recent modern humans in their anatomy. Femoral curvature is a good indicator of activity level and habitual loading of the lower limb, indicating higher activity levels in Neanderthals than modern humans. These differences contradict robusticity studies and the archaeological record, and would suggest that femoral morphology, and curvature in particular, in Neanderthals may not be explained by adult behavior alone and could be the result of genetic drift, natural selection or differences in behavior during ontogeny.

  4. 3D CT spine data segmentation and analysis of vertebrae bone lesions.

    PubMed

    Peter, R; Malinsky, M; Ourednicek, P; Jan, J

    2013-01-01

    A method is presented aiming at detecting and classifying bone lesions in 3D CT data of human spine, via Bayesian approach utilizing Markov random fields. A developed algorithm for necessary segmentation of individual possibly heavily distorted vertebrae based on 3D intensity modeling of vertebra types is presented as well.

  5. Localization of spots in FISH images of breast cancer using 3-D shape analysis.

    PubMed

    Les, T; Markiewicz, T; Osowski, S; Jesiotr, M; Kozlowski, W

    2016-06-01

    The fluorescence in situ (FISH) belongs to the most often used molecular cytogenetic techniques, applied in many areas of diagnosis and research. The analysis of FISH images relies on localization and counting the red and green spots in order to determine HER2 status of the breast cancer samples. The algorithm of spot localization presented in the paper is based on 3-D shape analysis of the image objects. The subsequent regions of the image are matched to the reference pattern and the results of this matching influence localization of spots. The paper compares different shapes of the reference pattern and their efficiency in spot localization. The numerical experiments have been performed on the basis of 12 cases (patients), each represented by three images. Few thousands of cells have been analysed. The quantitative analyses comparing different versions of algorithm are presented and compared to the expert results. The best version of the procedure provides the absolute relative difference to the expert results smaller than 3%. These results confirm high efficiency of the proposed approach to the spot identification. The proposed method of FISH image analysis improves the efficiency of detecting fluorescent signals in FISH images. The evaluation results are encouraging for further testing of the developed automatic system directed to application in medical practice.

  6. Analysis of simple 2-D and 3-D metal structures subjected to fragment impact

    NASA Technical Reports Server (NTRS)

    Witmer, E. A.; Stagliano, T. R.; Spilker, R. L.; Rodal, J. J. A.

    1977-01-01

    Theoretical methods were developed for predicting the large-deflection elastic-plastic transient structural responses of metal containment or deflector (C/D) structures to cope with rotor burst fragment impact attack. For two-dimensional C/D structures both, finite element and finite difference analysis methods were employed to analyze structural response produced by either prescribed transient loads or fragment impact. For the latter category, two time-wise step-by-step analysis procedures were devised to predict the structural responses resulting from a succession of fragment impacts: the collision force method (CFM) which utilizes an approximate prediction of the force applied to the attacked structure during fragment impact, and the collision imparted velocity method (CIVM) in which the impact-induced velocity increment acquired by a region of the impacted structure near the impact point is computed. The merits and limitations of these approaches are discussed. For the analysis of 3-d responses of C/D structures, only the CIVM approach was investigated.

  7. Reservoir lithofacies analysis using 3D seismic data in dissimilarity space

    NASA Astrophysics Data System (ADS)

    Bagheri, M.; Riahi, M. A.; Hashemi, H.

    2013-06-01

    Seismic data interpretation is one of the most important steps in exploration seismology. Seismic facies analysis (SFA) with emphasis on lithofacies can be used to extract more information about structures and geology, which results in seismic interpretation enhancement. Facies analysis is based on unsupervised and supervised classification using seismic attributes. In this paper, supervised classification by a support vector machine using well logs and seismic attributes is applied. Dissimilarity as a new measuring space is employed, after which classification is carried out. Often, SFA is carried out in a feature space in which each dimension stands as a seismic attribute. Different facies show lots of class overlap in the feature space; hence, high classification error values are reported. Therefore, decreasing class overlap before classification is a necessary step to be targeted. To achieve this goal, a dissimilarity space is initially created. As a result of the definition of the new space, the class overlap between objects (seismic samples) is reduced and hence the classification can be done reliably. This strategy causes an increase in the accuracy of classification, and a more trustworthy lithofacies analysis is attained. For applying this method, 3D seismic data from an oil field in Iran were selected and the results obtained by a support vector classifier (SVC) in dissimilarity space are presented, discussed and compared with the SVC applied in conventional feature space.

  8. Comparison of a quasi-3D analysis and experimental performance for three compact radial turbines

    NASA Technical Reports Server (NTRS)

    Simonyi, P. S.; Boyle, R. J.

    1991-01-01

    An experimental aerodynamic evaluation of three compact radial turbine builds was performed. Two rotors which were 40 to 50 percent shorter in axial length than conventional state of the art radial rotors were tested. A single nozzle design was used. One rotor was tested with the nozzle at two stagger angle settings. A second rotor was tested with the nozzle in only the closed down setting. Experimental results were compared to predict results from a quasi-3D inviscid and boundary layer analysis, called Meridl/Tsonic/Blayer (MTSB). This analysis was used to predict turbine performance. It has previously been calibrated only for axial, not radial, turbomachinery. The predicted and measured efficiencies were compared at the design point for the three turbines. At the design points the analysis overpredicted the efficiency by less than 1.7 points. Comparisons were also made at off-design operating points. The results of these comparisons showed the importance of an accurate clearance model for efficiency predictions and also that there are deficiencies in the incidence loss model used.

  9. Earthscape, a Multi-Purpose Interactive 3d Globe Viewer for Hybrid Data Visualization and Analysis

    NASA Astrophysics Data System (ADS)

    Sarthou, A.; Mas, S.; Jacquin, M.; Moreno, N.; Salamon, A.

    2015-08-01

    The hybrid visualization and interaction tool EarthScape is presented here. The software is able to display simultaneously LiDAR point clouds, draped videos with moving footprint, volume scientific data (using volume rendering, isosurface and slice plane), raster data such as still satellite images, vector data and 3D models such as buildings or vehicles. The application runs on touch screen devices such as tablets. The software is based on open source libraries, such as OpenSceneGraph, osgEarth and OpenCV, and shader programming is used to implement volume rendering of scientific data. The next goal of EarthScape is to perform data analysis using ENVI Services Engine, a cloud data analysis solution. EarthScape is also designed to be a client of Jagwire which provides multisource geo-referenced video fluxes. When all these components will be included, EarthScape will be a multi-purpose platform that will provide at the same time data analysis, hybrid visualization and complex interactions. The software is available on demand for free at france@exelisvis.com.

  10. Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

    PubMed

    Tward, Daniel J; Siewerdsen, Jeffrey H

    2008-12-01

    The physical factors that govern 2D and 3D imaging performance may be understood from quantitative analysis of the spatial-frequency-dependent signal and noise transfer characteristics [e.g., modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta (NEQ)] along with a task-based assessment of performance (e.g., detectability index). This paper advances a theoretical framework based on cascaded systems analysis for calculation of such metrics in cone-beam CT (CBCT). The model considers the 2D projection NPS propagated through a series of reconstruction stages to yield the 3D NPS and allows quantitative investigation of tradeoffs in image quality associated with acquisition and reconstruction techniques. While the mathematical process of 3D image reconstruction is deterministic, it is shown that the process is irreversible, the associated reconstruction parameters significantly affect the 3D DQE and NEQ, and system optimization should consider the full 3D imaging chain. Factors considered in the cascade include: system geometry; number of projection views; logarithmic scaling; ramp, apodization, and interpolation filters; 3D back-projection; and 3D sampling (noise aliasing). The model is validated in comparison to experiment across a broad range of dose, reconstruction filters, and voxel sizes, and the effects of 3D noise correlation on detectability are explored. The work presents a model for the 3D NPS, DQE, and NEQ of CBCT that reduces to conventional descriptions of axial CT as a special case and provides a fairly general framework that can be applied to the design and optimization of CBCT systems for various applications.

  11. The MHOST finite element program: 3-D inelastic analysis methods for hot section components. Volume 2: User's manual

    NASA Technical Reports Server (NTRS)

    Nakazawa, Shohei

    1989-01-01

    The user options available for running the MHOST finite element analysis package is described. MHOST is a solid and structural analysis program based on the mixed finite element technology, and is specifically designed for 3-D inelastic analysis. A family of 2- and 3-D continuum elements along with beam and shell structural elements can be utilized, many options are available in the constitutive equation library, the solution algorithms and the analysis capabilities. The outline of solution algorithms is discussed along with the data input and output, analysis options including the user subroutines and the definition of the finite elements implemented in the program package.

  12. BWR station blackout: A RISMC analysis using RAVEN and RELAP5-3D

    SciTech Connect

    Mandelli, D.; Smith, C.; Riley, T.; Nielsen, J.; Alfonsi, A.; Cogliati, J.; Rabiti, C.; Schroeder, J.

    2016-01-01

    The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates and improved operations. In order to evaluate the impact of these factors on the safety of the plant, the Risk-Informed Safety Margin Characterization (RISMC) project aims to provide insights to decision makers through a series of simulations of the plant dynamics for different initial conditions and accident scenarios. This paper presents a case study in order to show the capabilities of the RISMC methodology to assess impact of power uprate of a Boiling Water Reactor system during a Station Black-Out accident scenario. We employ a system simulator code, RELAP5-3D, coupled with RAVEN which perform the stochastic analysis. Lastly, our analysis is performed by: 1) sampling values from a set of parameters from the uncertainty space of interest, 2) simulating the system behavior for that specific set of parameter values and 3) analyzing the outcomes from the set of simulation runs.

  13. 3D Elasto-Plastic Stress Analysis by the Method of Arbitrary Lines

    NASA Astrophysics Data System (ADS)

    Kaminishi, Ken; Ando, Ryuma

    The method of arbitrary lines (MAL) constitutes a general dimensional reduction methodology for elliptic boundary value problems (BVP) in arbitrary two- and three-dimensional domains by solving systems of one-dimensional boundary value ordinary differential equations (ODEs). It has been already applied to two-dimensional problem, and the good results have been reported. In this work, we consider the extension of the MAL to three-dimensional elasto-plastic stress analysis. We first give the MAL formulation of three-dimensional elasto-plastic problems. Although the MAL formulation is derived from the principle of three-dimensional increment virtual work as well as the finite element method (FEM), the MAL is different from FEM in that displacement increment and virtual displacement increment are expressed continuous functions along one direction and shape-functions along other two directions. Substituting displacement increment and virtual displacement increment into the principle of three-dimensional increment virtual work, we have a system of ODEs. The three-dimensional elasto-plastic analysis of BGA model, which was a method of the solder joints of electronic component, was carried out. As results, it was confirmed that to solve 3D elasto-plastic problem at the good accuracy was possible by the MAL.

  14. Evaluation of axial and lateral modal superposition for general 3D drilling riser analysis

    SciTech Connect

    Burgdorf, O. Jr.

    1996-12-31

    A 3D partially non-linear transient fully-coupled riser analysis method is evaluated which uses modal superposition of independently extracted lateral and axial modes. Many lateral modes are combined with a lesser number axial modes to minimize adverse time step requirements typically induced by axial flexibility in direct time integration of beam-column elements. The reduced computer time option enables much faster parametric analysis of hang-off, as well as other connected drilling environments normally examined. Axial-lateral coupling is explicitly enforced and, resonance fidelity is preserved when excitation is near or coincident with axial natural periods. Reasonable correlation is shown with envelopes of test case dynamic responses published by API. Applicability of the method is limited by linearity assumptions indigenous to modal representation of dynamic deflections relative to a mean deflected shape. Sensitivities of incipient buckling during hang-off to axial damping and stiffness are described for an example 6,000 ft. deep composite drilling riser system.

  15. Segmentation of vascular structures and hematopoietic cells in 3D microscopy images and quantitative analysis

    NASA Astrophysics Data System (ADS)

    Mu, Jian; Yang, Lin; Kamocka, Malgorzata M.; Zollman, Amy L.; Carlesso, Nadia; Chen, Danny Z.

    2015-03-01

    In this paper, we present image processing methods for quantitative study of how the bone marrow microenvironment changes (characterized by altered vascular structure and hematopoietic cell distribution) caused by diseases or various factors. We develop algorithms that automatically segment vascular structures and hematopoietic cells in 3-D microscopy images, perform quantitative analysis of the properties of the segmented vascular structures and cells, and examine how such properties change. In processing images, we apply local thresholding to segment vessels, and add post-processing steps to deal with imaging artifacts. We propose an improved watershed algorithm that relies on both intensity and shape information and can separate multiple overlapping cells better than common watershed methods. We then quantitatively compute various features of the vascular structures and hematopoietic cells, such as the branches and sizes of vessels and the distribution of cells. In analyzing vascular properties, we provide algorithms for pruning fake vessel segments and branches based on vessel skeletons. Our algorithms can segment vascular structures and hematopoietic cells with good quality. We use our methods to quantitatively examine the changes in the bone marrow microenvironment caused by the deletion of Notch pathway. Our quantitative analysis reveals property changes in samples with deleted Notch pathway. Our tool is useful for biologists to quantitatively measure changes in the bone marrow microenvironment, for developing possible therapeutic strategies to help the bone marrow microenvironment recovery.

  16. BWR station blackout: A RISMC analysis using RAVEN and RELAP5-3D

    DOE PAGES

    Mandelli, D.; Smith, C.; Riley, T.; ...

    2016-01-01

    The existing fleet of nuclear power plants is in the process of extending its lifetime and increasing the power generated from these plants via power uprates and improved operations. In order to evaluate the impact of these factors on the safety of the plant, the Risk-Informed Safety Margin Characterization (RISMC) project aims to provide insights to decision makers through a series of simulations of the plant dynamics for different initial conditions and accident scenarios. This paper presents a case study in order to show the capabilities of the RISMC methodology to assess impact of power uprate of a Boiling Watermore » Reactor system during a Station Black-Out accident scenario. We employ a system simulator code, RELAP5-3D, coupled with RAVEN which perform the stochastic analysis. Lastly, our analysis is performed by: 1) sampling values from a set of parameters from the uncertainty space of interest, 2) simulating the system behavior for that specific set of parameter values and 3) analyzing the outcomes from the set of simulation runs.« less

  17. 3D geometric morphometric analysis of the proximal epiphysis of the hominoid humerus

    PubMed Central

    Arias-Martorell, Julia; Potau, Josep Maria; Bello-Hellegouarch, Gaëlle; Pastor, Juan Francisco; Pérez-Pérez, Alejandro

    2012-01-01

    In this study we perform a three-dimensional geometric morphometric (3D GM) analysis of the proximal epiphysis of the humerus in extant great apes, including humans, in order to accurately describe the functional anatomical differences between these taxa. In addition, a fossil hominin specimen of Australopithecus afarensis was included in a multivariate GM analysis in order to test the potential of this methodological approach for making locomotor inferences from fossil remains. The results obtained show significant differences in proximal humeral morphology among the taxa studied, which had thus far largely remained unnoticed. Based on morphofunctional considerations, these anatomical differences can be correlated to differences in the locomotor repertoires of the taxa, thus confirming that the proximal humerus is suitable for constructing paleobiological inferences about locomotion. Modern humans display markedly divergent features, which set them apart from both the extant great apes and the fossil hominin A. afarensis. The morphology of the proximal epiphysis of the humerus of the latter more closely resembles that of the orangutans, thus suggesting that despite hindlimb adaptations to bipedalism, the forelimb of this taxon was still functionally involved in arboreal behaviors, such as climbing or suspension. PMID:22946496

  18. A detailed 3D finite element analysis of the peeling behaviour of a gecko spatula.

    PubMed

    Sauer, Roger A; Holl, Matthias

    2013-01-01

    This paper presents a detailed finite element analysis of the adhesion of a gecko spatula. The gecko spatulae form the tips of the gecko foot hairs that transfer the adhesional and frictional forces between substrate and foot. The analysis is based on a parameterised description of the 3D geometry of the spatula that only requires 12 parameters. The adhesion is described by a nonlinear computational contact formulation that accounts for the van der Waals interaction between spatula and substrate. The spatula adhesion model is implemented using an enriched contact finite element formulation recently developed by the first author. The finite element model is then used to simulate the peeling behaviour of the gecko spatula under applied vertical and rotational loading for various model parameters. Variations of the material stiffness, adhesional strength and range, stiction, spatula size and spatula inclination are considered to account for the natural variation of spatula properties. The study demonstrates that the spatula can function over a wide range of conditions. The computed pull-off forces are in agreement with experimental results reported in the literature. The study also examines the energy required for the spatula pull-off. The proposed model is ideal to study the influence of substrate roughness on the spatula adhesion, as is finally demonstrated.

  19. 3D integration of microcomponents in a single glass chip by femtosecond laser direct writing for biochemical analysis

    NASA Astrophysics Data System (ADS)

    Sugioka, Koji; Hanada, Yasutaka; Midorikawa, Katsumi

    2007-05-01

    3D integration of microcomponents in a single glass chip by femtosecond laser direct writing followed by post annealing and successive wet etching is described for application to biochemical analysis. Integration of microfluidics and microoptics realized some functional microdevices like a μ-fluidic dye laser and a biosensor. As one of practical applications, we demonstrate inspection of living microorganisms using the microchip with 3D microfluidic structures fabricated by the present technique.

  20. Parameterization and Analysis of 3-D Solar Radiative Transfer in Clouds: Final Report

    SciTech Connect

    Jerry Y. Harrington

    2012-09-21

    This document reports on the research that we have done over the course of our two-year project. The report also covers the research done on this project during a 1 year no-cost extension of the grant. Our work has had two main, inter-related thrusts: The first thrust was to characterize the response of stratocumulus cloud structure and dynamics to systematic changes in cloud infrared radiative cooling and solar heating using one-dimensional radiative transfer models. The second was to couple a three-dimensional (3-D) solar radiative transfer model to the Large Eddy Simulation (LES) model that we use to simulate stratocumulus. The purpose of the studies with 3-D radiative transfer was to examine the possible influences of 3-D photon transport on the structure, evolution, and radiative properties of stratocumulus. While 3-D radiative transport has been examined in static cloud environments, few studies have attempted to examine whether the 3-D nature of radiative absorption and emission influence the structure and evolution of stratocumulus. We undertook this dual approach because only a small number of LES simulations with the 3-D radiative transfer model are possible due to the high computational costs. Consequently, LES simulations with a 1-D radiative transfer solver were used in order to examine the portions of stratocumulus parameter space that may be most sensitive to perturbations in the radiative fields. The goal was then to explore these sensitive regions with LES using full 3-D radiative transfer. Our overall goal was to discover whether 3-D radiative processes alter cloud structure and evolution, and whether this may have any indirect implications for cloud radiative properties. In addition, we collaborated with Dr. Tamas Varni, providing model output fields for his attempt at parameterizing 3-D radiative effects for cloud models.

  1. Nondestructive 3D confocal laser imaging with deconvolution of seven whole stardust tracks with complementary XRF and quantitative analysis

    SciTech Connect

    Greenberg, M.; Ebel, D.S.

    2009-03-19

    We present a nondestructive 3D system for analysis of whole Stardust tracks, using a combination of Laser Confocal Scanning Microscopy and synchrotron XRF. 3D deconvolution is used for optical corrections, and results of quantitative analyses of several tracks are presented. The Stardust mission to comet Wild 2 trapped many cometary and ISM particles in aerogel, leaving behind 'tracks' of melted silica aerogel on both sides of the collector. Collected particles and their tracks range in size from submicron to millimeter scale. Interstellar dust collected on the obverse of the aerogel collector is thought to have an average track length of {approx}15 {micro}m. It has been our goal to perform a total non-destructive 3D textural and XRF chemical analysis on both types of tracks. To that end, we use a combination of Laser Confocal Scanning Microscopy (LCSM) and X Ray Florescence (XRF) spectrometry. Utilized properly, the combination of 3D optical data and chemical data provides total nondestructive characterization of full tracks, prior to flattening or other destructive analysis methods. Our LCSM techniques allow imaging at 0.075 {micro}m/pixel, without the use of oil-based lenses. A full textural analysis on track No.82 is presented here as well as analysis of 6 additional tracks contained within 3 keystones (No.128, No.129 and No.140). We present a method of removing the axial distortion inherent in LCSM images, by means of a computational 3D Deconvolution algorithm, and present some preliminary experiments with computed point spread functions. The combination of 3D LCSM data and XRF data provides invaluable information, while preserving the integrity of the samples for further analysis. It is imperative that these samples, the first extraterrestrial solids returned since the Apollo era, be fully mapped nondestructively in 3D, to preserve the maximum amount of information prior to other, destructive analysis.

  2. In vitro analysis of chemotactic leukocyte migration in 3D environments.

    PubMed

    Sixt, Michael; Lämmermann, Tim

    2011-01-01

    Cell migration on two-dimensional (2D) substrates follows entirely different rules than cell migration in three-dimensional (3D) environments. This is especially relevant for leukocytes that are able to migrate in the absence of adhesion receptors within the confined geometry of artificial 3D extracellular matrix scaffolds and within the interstitial space in vivo. Here, we describe in detail a simple and economical protocol to visualize dendritic cell migration in 3D collagen scaffolds along chemotactic gradients. This method can be adapted to other cell types and may serve as a physiologically relevant paradigm for the directed locomotion of most amoeboid cells.

  3. Analysis of 3D-printed metal for rapid-prototyped reflective terahertz optics

    NASA Astrophysics Data System (ADS)

    Headland, Daniel; Withayachumnankul, Withawat; Webb, Michael; Ebendorff-Heidepriem, Heike; Luiten, Andre; Abbott, Derek

    2016-07-01

    We explore the potential of 3D metal printing to realize complex conductive terahertz devices. Factors impacting performance such as printing resolution, surface roughness, oxidation, and material loss are investigated via analytical, numerical, and experimental approaches. The high degree of control offered by a 3D-printed topology is exploited to realize a zone plate operating at 530 GHz. Reflection efficiency at this frequency is found to be over 90%. The high-performance of this preliminary device suggest that 3D metal printing can play a strong role in guided-wave and general beam control devices in the terahertz range.

  4. Super Cooled Large Droplet Analysis of Several Geometries Using LEWICE3D Version 3

    NASA Technical Reports Server (NTRS)

    Bidwell, Colin S.

    2011-01-01

    Super Cooled Large Droplet (SLD) collection efficiency calculations were performed for several geometries using the LEWICE3D Version 3 software. The computations were performed using the NASA Glenn Research Center SLD splashing model which has been incorporated into the LEWICE3D Version 3 software. Comparisons to experiment were made where available. The geometries included two straight wings, a swept 64A008 wing tip, two high lift geometries, and the generic commercial transport DLR-F4 wing body configuration. In general the LEWICE3D Version 3 computations compared well with the 2D LEWICE 3.2.2 results and with experimental data where available.

  5. RESTRUCTURING RELAP5-3D FOR NEXT GENERATION NUCLEAR PLANT ANALYSIS

    SciTech Connect

    Donna Post Guillen; George L. Mesina; Joshua M. Hykes

    2006-06-01

    RELAP5-3D is used worldwide for analyzing nuclear reactors under both operational transients and postulated accident conditions. Development of the RELAP code series began in 1975 and since that time the code has been continuously improved, enhanced, verified and validated [1]. Since RELAP5-3D will continue to be the premier thermal hydraulics tool well into the future, it is necessary to modernize the code to accommodate the incorporation of additional capabilities to support the development of the next generation of nuclear reactors [2]. This paper discusses the reengineering of RELAP5-3D into structured code.

  6. Gait analysis in low lumbar myelomeningocele patients with unilateral hip dislocation or subluxation.

    PubMed

    Gabrieli, Ana Paula T; Vankoski, Stephen J; Dias, Luciano S; Milani, Carlo; Lourenco, Alexandre; Filho, Jose Laredo; Novak, Robert

    2003-01-01

    The surgical indications for the treatment of unilateral hip dislocations or subluxations in patients with low lumbar myelomeningocele remain highly debatable. This study examines the influence of unilateral hip dislocation or subluxation on the gait of these patients using three-dimensional gait analysis. Twenty patients with a diagnosis of low lumbar myelomeningocele underwent three-dimensional gait analysis. All patients were community ambulators with solid ankle-foot orthoses and crutches who presented with unilateral hip dislocation or subluxation and no scoliosis. The patients were divided in two groups. Group 1 comprised 10 patients who demonstrated either no evidence of hip flexion or adduction contractures or symmetric hip contractures. Group 2 comprised 10 patients with unilateral hip flexion and/or adduction contractures. Pelvic and hip kinematics were assessed to determine the symmetry of motion between the involved and the noninvolved side during walking. Seven patients from group 1 walked with a symmetric gait pattern; only two patients from group 2 walked with a symmetric pattern. Gait symmetry corresponded to the absence of hip contractures or bilateral symmetrical hip contractures and had no relation to the presence of hip dislocation. The authors concluded that reduction of the hip is unnecessary.

  7. Contribution of clinical gait analysis to single-event multi-level surgery in children with cerebral palsy.

    PubMed

    Khouri, N; Desailly, E

    2017-02-01

    Clinical gait analysis (CGA) has been proven useful in understanding the gait disturbances seen in children and adolescents with cerebral palsy. Another major benefit provided by CGA is a clinical and scientific evaluation of how orthopaedic surgical procedures modify gait. The information provided by instrumented CGA complements the clinical data, and the two must be interpreted jointly. Although there is some variability in the surgical details of therapeutic strategies, CGA undoubtedly influences the planning of surgery. Although CGA improves surgical outcomes, these remain challenging to predict. CGA seems cost-effective. Internal hip rotation gait is used as an example to illustrate those benefits.

  8. Free energy force field (FEFF) 3D-QSAR analysis of a set of Plasmodium falciparum dihydrofolate reductase inhibitors

    NASA Astrophysics Data System (ADS)

    Santos-Filho, Osvaldo A.; Mishra, Rama K.; Hopfinger, A. J.

    2001-09-01

    Free energy force field (FEFF) 3D-QSAR analysis was used to construct ligand-receptor binding models for a set of 18 structurally diverse antifolates including pyrimethamine, cycloguanil, methotrexate, aminopterin and trimethoprim, and 13 pyrrolo[2,3-d]pyrimidines. The molecular target (`receptor') used was a 3D-homology model of a specific mutant type of Plasmodium falciparum (Pf) dihydrofolate reductase (DHFR). The dependent variable of the 3D-QSAR models is the IC50 inhibition constant for the specific mutant type of PfDHFR. The independent variables of the 3D-QSAR models (the descriptors) are scaled energy terms of a modified first-generation AMBER force field combined with a hydration shell aqueous solvation model and a collection of 2D-QSAR descriptors often used in QSAR studies. Multiple temperature molecular dynamics simulation (MDS) and the genetic function approximation (GFA) were employed using partial least square (PLS) and multidimensional linear regressions as the fitting functions to develop FEFF 3D-QSAR models for the binding process. The significant FEFF energy terms in the best 3D-QSAR models include energy contributions of the direct ligand-receptor interaction. Some changes in conformational energy terms of the ligand due to binding to the enzyme are also found to be important descriptors. The FEFF 3D-QSAR models indicate some structural features perhaps relevant to the mechanism of resistance of the PfDHFR to current antimalarials. The FEFF 3D-QSAR models are also compared to receptor-independent (RI) 4D-QSAR models developed in an earlier study and subsequently refined using recently developed generalized alignment rules.

  9. Multi-complexity ensemble measures for gait time series analysis: application to diagnostics, monitoring and biometrics.

    PubMed

    Gavrishchaka, Valeriy; Senyukova, Olga; Davis, Kristina

    2015-01-01

    Previously, we have proposed to use complementary complexity measures discovered by boosting-like ensemble learning for the enhancement of quantitative indicators dealing with necessarily short physiological time series. We have confirmed robustness of such multi-complexity measures for heart rate variability analysis with the emphasis on detection of emerging and intermittent cardiac abnormalities. Recently, we presented preliminary results suggesting that such ensemble-based approach could be also effective in discovering universal meta-indicators for early detection and convenient monitoring of neurological abnormalities using gait time series. Here, we argue and demonstrate that these multi-complexity ensemble measures for gait time series analysis could have significantly wider application scope ranging from diagnostics and early detection of physiological regime change to gait-based biometrics applications.

  10. Recognizing Non-Stationary Walking based on Gait Analysis using Laser Scanners

    NASA Astrophysics Data System (ADS)

    Nakamura, Katsuyuki; Shao, Xiaowei; Zhao, Huijing; Shibasaki, Ryosuke

    In this paper the authors propose a method for recognizing non-stationary walking based on a gait analysis using multiple laser range scanners. The proposed method consists of the following procedures: (1) people tracking; (2) detection of gait features; (3) recognition of non-stationary walking. First, people tracking is performed by recognizing patterns in which the range data obtained near ankle rhythmically. Next, gait analysis is performed by the spatio-temporal clustering using Mean Shift algorithm. Finally, One Class Support Vector Machine (One Class SVM) is applied for learning and classifying a non-stationary walking. The experiment in a station concourse in Tokyo shows the overall accuracy of 98.4% by the proposed method.

  11. 3D tumor spheroids: an overview on the tools and techniques used for their analysis.

    PubMed

    Costa, Elisabete C; Moreira, André F; de Melo-Diogo, Duarte; Gaspar, Vítor M; Carvalho, Marco P; Correia, Ilídio J

    2016-12-01

    In comparison with 2D cell culture models, 3D spheroids are able to accurately mimic some features of solid tumors, such as their spatial architecture, physiological responses, secretion of soluble mediators, gene expression patterns and drug resistance mechanisms. These unique characteristics highlight the potential of 3D cellular aggregates to be used as in vitro models for screening new anticancer therapeutics, both at a small and large scale. Nevertheless, few reports have focused on describing the tools and techniques currently available to extract significant biological data from these models. Such information will be fundamental to drug and therapeutic discovery process using 3D cell culture models. The present review provides an overview of the techniques that can be employed to characterize and evaluate the efficacy of anticancer therapeutics in 3D tumor spheroids.

  12. Mitral valve analysis using a novel 3D holographic display: a feasibility study of 3D ultrasound data converted to a holographic screen.

    PubMed

    Beitnes, Jan Otto; Klæboe, Lars Gunnar; Karlsen, Jørn Skaarud; Urheim, Stig

    2015-02-01

    The aim of the present study was to test the feasibility of analyzing 3D ultrasound data on a novel holographic display. An increasing number of mini-invasive procedures for mitral valve repair require more effective visualization to improve patient safety and speed of procedures. A novel 3D holographic display has been developed and may have the potential to guide interventional cardiac procedures in the near future. Forty patients with degenerative mitral valve disease were analyzed. All had complete 2D transthoracic (TTE) and transoesophageal (TEE) echocardiographic examinations. In addition, 3D TTE of the mitral valve was obtained and recordings were converted from the echo machine to the holographic screen. Visual inspection of the mitral valve during surgery or TEE served as the gold standard. 240 segments were analyzed by 2 independent observers. A total of 53 segments were prolapsing. The majority included P2 (31), the remaining located at A2 (8), A3 (6), P3 (5), P1 (2) and A1 (1). The sensitivity and specificity of the 3D display was 87 and 99 %, respectively (observer I), and for observer II 85 and 97 %, respectively. The accuracies and precisions were 96.7 and 97.9 %, respectively, (observer I), 94.3 and 88.2 % (observer II), and inter-observer agreement was 0.954 with Cohen's Kappa 0.86. We were able to convert 3D ultrasound data to the holographic display. A very high accuracy and precision was shown, demonstrating the feasibility of analyzing 3D echo of the mitral valve on the holographic screen.

  13. Integrated Idl Tool For 3d Modeling And Imaging Data Analysis

    NASA Astrophysics Data System (ADS)

    Nita, Gelu M.; Fleishman, G. D.; Gary, D. E.; Kuznetsov, A. A.; Kontar, E. P.

    2012-05-01

    Addressing many key problems in solar physics requires detailed analysis of non-simultaneous imaging data obtained in various wavelength domains with different spatial resolution and their comparison with each other supplied by advanced 3D physical models. To facilitate achieving this goal, we have undertaken a major enhancement and improvements of IDL-based simulation tools developed earlier for modeling microwave and X-ray emission. The greatly enhanced object-based architecture provides interactive graphic user interface that allows the user i) to import photospheric magnetic field maps and perform magnetic field extrapolations to almost instantly generate 3D magnetic field models, ii) to investigate the magnetic topology of these models by interactively creating magnetic field lines and associated magnetic field tubes, iii) to populate them with user-defined nonuniform thermal plasma and anisotropic nonuniform nonthermal electron distributions; and iv) to calculate the spatial and spectral properties of radio and X-ray emission. The application integrates DLL and Shared Libraries containing fast gyrosynchrotron emission codes developed in FORTRAN and C++, soft and hard X-ray codes developed in IDL, and a potential field extrapolation DLL produced based on original FORTRAN code developed by V. Abramenko and V. Yurchishin. The interactive interface allows users to add any user-defined IDL or external callable radiation code, as well as user-defined magnetic field extrapolation routines. To illustrate the tool capabilities, we present a step-by-step live computation of microwave and X-ray images from realistic magnetic structures obtained from a magnetic field extrapolation preceding a real event, and compare them with the actual imaging data produced by NORH and RHESSI instruments. This work was supported in part by NSF grants AGS-0961867, AST-0908344, AGS-0969761, and NASA grants NNX10AF27G and NNX11AB49G to New Jersey Institute of Technology, by a UK STFC

  14. Breast Density Analysis with Automated Whole-Breast Ultrasound: Comparison with 3-D Magnetic Resonance Imaging.

    PubMed

    Chen, Jeon-Hor; Lee, Yan-Wei; Chan, Si-Wa; Yeh, Dah-Cherng; Chang, Ruey-Feng

    2016-05-01

    In this study, a semi-automatic breast segmentation method was proposed on the basis of the rib shadow to extract breast regions from 3-D automated whole-breast ultrasound (ABUS) images. The density results were correlated with breast density values acquired with 3-D magnetic resonance imaging (MRI). MRI images of 46 breasts were collected from 23 women without a history of breast disease. Each subject also underwent ABUS. We used Otsu's thresholding method on ABUS images to obtain local rib shadow information, which was combined with the global rib shadow information (extracted from all slice projections) and integrated with the anatomy's breast tissue structure to determine the chest wall line. The fuzzy C-means classifier was used to extract the fibroglandular tissues from the acquired images. Whole-breast volume (WBV) and breast percentage density (BPD) were calculated in both modalities. Linear regression was used to compute the correlation of density results between the two modalities. The consistency of density measurement was also analyzed on the basis of intra- and inter-operator variation. There was a high correlation of density results between MRI and ABUS (R(2) = 0.798 for WBV, R(2) = 0.825 for PBD). The mean WBV from ABUS images was slightly smaller than the mean WBV from MR images (MRI: 342.24 ± 128.08 cm(3), ABUS: 325.47 ± 136.16 cm(3), p < 0.05). In addition, the BPD calculated from MR images was smaller than the BPD from ABUS images (MRI: 24.71 ± 15.16%, ABUS: 28.90 ± 17.73%, p < 0.05). The intra-operator and inter-operator variant analysis results indicated that there was no statistically significant difference in breast density measurement variation between the two modalities. Our results revealed a high correlation in WBV and BPD between MRI and ABUS. Our study suggests that ABUS provides breast density information useful in the assessment of breast health.

  15. Electrical performance analysis of HTS synchronous motor based on 3D FEM

    NASA Astrophysics Data System (ADS)

    Baik, S. K.; Kwon, Y. K.; Kim, H. M.; Lee, J. D.; Kim, Y. C.; Park, G. S.

    2010-11-01

    A 1-MW class superconducting motor with High-Temperature Superconducting (HTS) field coil is analyzed and tested. This machine is a prototype to make sure applicability aimed at generator and industrial motor applications such as blowers, pumps and compressors installed in large plants. This machine has the HTS field coil made of Bi-2223 HTS wire and the conventional copper armature (stator) coils cooled by water. The 1-MW class HTS motor is analyzed by 3D electromagnetic Finite Element Method (FEM) to get magnetic field distribution, self and mutual inductance, and so forth. Especially excitation voltage (Back EMF) is estimated by using the mutual inductance between armature and field coils and compared with experimental result. Open and short circuit tests were conducted in generator mode while a 1.1-MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests and also compared with the analysis results from FEM.

  16. Design and mechanical analysis of a 3D-printed biodegradable biomimetic micro air vehicle wing

    NASA Astrophysics Data System (ADS)

    Salami, E.; Ganesan, P. B.; Ward, T. A.; Viyapuri, R.; Romli, F. I.

    2016-10-01

    The biomimetic micro air vehicles (BMAV) are unmanned, micro-scaled aircraft that are bio-inspired from flying organisms to achieve the lift and thrust by flapping their wings. There are still many technological challenges involved with designing the BMAV. One of these is designing the ultra-lightweight materials and structures for the wings that have enough mechanical strength to withstand continuous flapping at high frequencies. Insects achieve this by having chitin-based, wing frame structures that encompass a thin, film membrane. The main objectives of this study are to design a biodegradable BMAV wing (inspired from the dragonfly) and analyze its mechanical properties. The dragonfly-like wing frame structure was bio-mimicked and fabricated using a 3D printer. A chitosan nanocomposite film membrane was applied to the BMAV wing frames through casting method. Its mechanical performance was analyzed using universal testing machine (UTM). This analysis indicates that the tensile strength and Young's modulus of the wing with a membrane is nearly double that of the wing without a membrane, which allow higher wing beat frequencies and deflections that in turn enable a greater lifting performance.

  17. Analysis and modeling of 3D complex modulus tests on hot and warm bituminous mixtures

    NASA Astrophysics Data System (ADS)

    Pham, Nguyen Hoang; Sauzéat, Cédric; Di Benedetto, Hervé; González-León, Juan A.; Barreto, Gilles; Nicolaï, Aurélia; Jakubowski, Marc

    2015-05-01

    This paper presents the results of laboratory testing of hot and warm bituminous mixtures containing Reclaimed Asphalt Pavement (RAP). Complex modulus measurements, using the tension-compression test on cylindrical specimens, were conducted to determine linear viscoelastic (LVE) behavior. Sinusoidal cyclic loadings, with strain amplitude of approximately 50ṡ10-6, were applied at several temperatures (from -25 to +45 °C) and frequencies (from 0.03 Hz to 10 Hz). In addition to axial stresses and strains, radial strains were also measured. The complex modulus E ∗ and complex Poisson's ratios ν ∗ were then obtained in two perpendicular directions. Measured values in these two directions do not indicate anisotropy on Poisson's ratio. The time-temperature superposition principle (TTSP) was verified with good approximation in one-dimensional (1D) and three-dimensional (3D) conditions for the same values of shift factor. Experimental results were modeled using the 2S2P1D model previously developed at the University of Lyon/ENTPE. In addition, specific analysis showed that eventual damage created during complex modulus test is very small and is equivalent to the effect of an increase of temperature of about 0.25 °C.

  18. CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis

    PubMed Central

    Choi, Kyoungah; Lee, Impyeong

    2015-01-01

    We propose a novel approach to evaluating how effectively a closed circuit television (CCTV) system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system. PMID:26389909

  19. Cycle graph analysis for 3D roof structure modelling: Concepts and performance

    NASA Astrophysics Data System (ADS)

    Perera, Gamage Sanka Nirodha; Maas, Hans-Gerd

    2014-07-01

    The paper presents a cycle graph analysis approach to the automatic reconstruction of 3D roof models from airborne laser scanner data. The nature of convergences of topological relations of plane adjacencies, allowing for the reconstruction of roof corner geometries with preserved topology, can be derived from cycles in roof topology graphs. The topology between roof adjacencies is defined in terms of ridge-lines and step-edges. In the proposed method, the input point cloud is first segmented and roof topology is derived while extracting roof planes from identified non-terrain segments. Orientation and placement regularities are applied on weakly defined edges using a piecewise regularization approach prior to the reconstruction, which assists in preserving symmetries in building geometry. Roof corners are geometrically modelled using the shortest closed cycles and the outermost cycle derived from roof topology graph in which external target graphs are no longer required. Based on test results, we show that the proposed approach can handle complexities with nearly 90% of the detected roof faces reconstructed correctly. The approach allows complex height jumps and various types of building roofs to be firmly reconstructed without prior knowledge of primitive building types.

  20. Stress distribution on external hexagon implant system using 3d finite element analysis.

    PubMed

    Segundo, Regênio M H; Oshima, Hugo M S; Silva, Isaac N L; Júnior, Luis H B; Mota, Eduardo G; Coelho, Luiz F B

    2007-01-01

    The aim of this study was to compare and evaluate strain distribution on dental implant, abutment, screw and crown virtual models in the posterior region. The analysis was performed by means of a 3D virtual model developed by the PRO-ENGINEER System (PRO-ENGINEER, PTC, Needham, MA, USA ) with an external butt joint (3i Implant Innovations, Palm Beach, Florida), square headed Gold Tite abutment retainer screw (3i Implant Innovations, Palm Beach, Florida), STA abutment (3i Implant Innovations, Palm Beach, Florida), metal infrastructure of Ag-Pd alloy and feldspatic ceramic. The standard load was 382N at 15 degree angle to the implant axis, applied at 6 mm from the implant center at different observation points on the implant-screw set. The data showed that on the implant virtual model, the highest strain concentration was found at the interface between the implant platform and the abutment, and in the middle point of the 1st screw thread internal diameter on the load application side.

  1. Fibrillogenesis from nanosurfaces: multiphoton imaging and stereological analysis of collagen 3D self-assembly dynamics.

    PubMed

    Bancelin, Stéphane; Decencière, Etienne; Machairas, Vaïa; Albert, Claire; Coradin, Thibaud; Schanne-Klein, Marie-Claire; Aimé, Carole

    2014-09-21

    The assembly of proteins into fibrillar structures is an important process that concerns different biological contexts, including molecular medicine and functional biomaterials. Engineering of hybrid biomaterials can advantageously provide synergetic interactions of the biopolymers with an inorganic component to ensure specific supramolecular organization and dynamics. To this aim, we designed hybrid systems associating collagen and surface-functionalized silica particles and we built a new strategy to investigate fibrillogenesis processes in such multicomponents systems, working at the crossroads of chemistry, physics and mathematics. The self-assembly process was investigated by bimodal multiphoton imaging coupling second harmonic generation (SHG) and 2 photon excited fluorescence (2PEF). The in-depth spatial characterization of the system was further achieved using the three-dimensional analysis of the SHG/2PEF data via mathematical morphology processing. Quantitation of collagen distribution around particles offers strong evidence that the chemically induced confinement of the protein on the silica nanosurfaces has a key influence on the spatial extension of fibrillogenesis. This new approach is unique in the information it can provide on 3D dynamic hybrid systems and may be extended to other associations of fibrillar molecules with optically responsive nano-objects.

  2. CraMs: Craniometric Analysis Application Using 3D Skull Models.

    PubMed

    Dias, Paulo; Neves, Luis; Santos, Daniel; Coelho, Catarina; Ferreira, Maria Teresa; Santos, Helder; Silva, Samuel; Santos, Beatriz Sousa

    2015-01-01

    Craniometric analysis plays an important role in anthropology studies and forensics. This paper presents CraMs, an application using a new craniometric approach based on 3D models of the skull. The main objective is to obtain, through a process supervised by anthropologists, the main points of interest used to compute craniometric measurements. The application aids this process by analyzing the skull geometry and automatically providing points of interest. The application also allows for semiautomatic point detection, where the user provides an initial guess that might be refined based on the curvature of the skull, as well as the manual selection of any other points of interest. Moreover, results comparing measurements obtained with CraMs and traditional craniometry methods on eight skulls suggest that the application provides comparable craniometric measurements and lower inter-observer variability. This approach offers advantages such as an easier access to skulls with no risk of bone damage and the possibility of defining new measurements based on morphology or other skull characteristics, which are not possible using traditional methods.

  3. Fast Bayesian whole-brain fMRI analysis with spatial 3D priors.

    PubMed

    Sidén, Per; Eklund, Anders; Bolin, David; Villani, Mattias

    2017-02-01

    Spatial whole-brain Bayesian modeling of task-related functional magnetic resonance imaging (fMRI) is a great computational challenge. Most of the currently proposed methods therefore do inference in subregions of the brain separately or do approximate inference without comparison to the true posterior distribution. A popular such method, which is now the standard method for Bayesian single subject analysis in the SPM software, is introduced in Penny et al. (2005b). The method processes the data slice-by-slice and uses an approximate variational Bayes (VB) estimation algorithm that enforces posterior independence between activity coefficients in different voxels. We introduce a fast and practical Markov chain Monte Carlo (MCMC) scheme for exact inference in the same model, both slice-wise and for the whole brain using a 3D prior on activity coefficients. The algorithm exploits sparsity and uses modern techniques for efficient sampling from high-dimensional Gaussian distributions, leading to speed-ups without which MCMC would not be a practical option. Using MCMC, we are for the first time able to evaluate the approximate VB posterior against the exact MCMC posterior, and show that VB can lead to spurious activation. In addition, we develop an improved VB method that drops the assumption of independent voxels a posteriori. This algorithm is shown to be much faster than both MCMC and the original VB for large datasets, with negligible error compared to the MCMC posterior.

  4. CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis.

    PubMed

    Choi, Kyoungah; Lee, Impyeong

    2015-09-16

    We propose a novel approach to evaluating how effectively a closed circuit television (CCTV) system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system.

  5. Population-based 3D genome structure analysis reveals driving forces in spatial genome organization

    PubMed Central

    Li, Wenyuan; Kalhor, Reza; Dai, Chao; Hao, Shengli; Gong, Ke; Zhou, Yonggang; Li, Haochen; Zhou, Xianghong Jasmine; Le Gros, Mark A.; Larabell, Carolyn A.; Chen, Lin; Alber, Frank

    2016-01-01

    Conformation capture technologies (e.g., Hi-C) chart physical interactions between chromatin regions on a genome-wide scale. However, the structural variability of the genome between cells poses a great challenge to interpreting ensemble-averaged Hi-C data, particularly for long-range and interchromosomal interactions. Here, we present a probabilistic approach for deconvoluting Hi-C data into a model population of distinct diploid 3D genome structures, which facilitates the detection of chromatin interactions likely to co-occur in individual cells. Our approach incorporates the stochastic nature of chromosome conformations and allows a detailed analysis of alternative chromatin structure states. For example, we predict and experimentally confirm the presence of large centromere clusters with distinct chromosome compositions varying between individual cells. The stability of these clusters varies greatly with their chromosome identities. We show that these chromosome-specific clusters can play a key role in the overall chromosome positioning in the nucleus and stabilizing specific chromatin interactions. By explicitly considering genome structural variability, our population-based method provides an important tool for revealing novel insights into the key factors shaping the spatial genome organization. PMID:26951677

  6. Cluster Analysis and Web-Based 3-D Visualization of Large-scale Geophysical Data

    NASA Astrophysics Data System (ADS)

    Kadlec, B. J.; Yuen, D. A.; Bollig, E. F.; Dzwinel, W.; da Silva, C. R.

    2004-05-01

    We present a problem-solving environment WEB-IS (Web-based Data Interrogative System), which we have developed for remote analysis and visualization of geophysical data [Garbow et. al., 2003]. WEB-IS employs agglomerative clustering methods intended for feature extraction and studying the predictions of large magnitude earthquake events. Data-mining is accomplished using a mutual nearest meighbor (MNN) algorithm for extracting event clusters of different density and shapes based on a hierarchical proximity measure. Clustering schemes used in molecular dynamics [Da Silva et. al., 2002] are also considered for increasing computational efficiency using a linked cell algorithm for creating a Verlet neighbor list (VNL) and extracting different cluster structures by applying a canonical backtracking search on the VNL. Space and time correlations between the events are visualized dynamically in 3-D through a filter by showing clusters at different timescales according to defined units of time ranging from days to years. This WEB-IS functionality was tested both on synthetic [Eneva and Ben-Zion, 1997] and actual earthquake catalogs of Japanese earthquakes and can be applied to the soft-computing data mining methods used in hydrology and geoinformatics. Da Silva, C.R.S., Justo, J.F., Fazzio, A., Phys Rev B, vol., 65, 2002. Eneva, M., Ben-Zion, Y.,J. Geophys. Res., 102, 17785-17795, 1997. Garbow, Z.A., Yuen, D.A., Erlebacher, G., Bollig, E.F., Kadlec, B.J., Vis. Geosci., 2003.

  7. Filtered chorochronic interface as a capability for 3-D unsteady throughflow analysis of multistage turbomachinery

    NASA Astrophysics Data System (ADS)

    Gerolymos, G. A.

    2013-02-01

    This note reviews the widely used phased-lagged [Erdos, J. L., E. Alzner, and W. McNally. 1977. AIAA Journal 15: 1559-68.] approach and corresponding chorochronic interface relations [Gerolymos G. A., G. J. Michon, and J. Neubauer. 2002. Journal of Propulsion and Power 18: 1139-52.] and explores its potential extension to the approximate unsteady throughflow analysis of multistage turbomachinery. The basic relations pertaining to the binary blade-row interaction case, for which chorochronic periodicity is exact in a phase-averaged rans framework, are briefly formulated, and selected computational examples illustrate the application of the method. Then, the filtered chorochronic interface is defined as the unsteady counterpart of the well-known mixing-plane concept. This interface takes into account only those tθ-waves which are compatible with the interaction of the immediately upstream and downstream blade-rows. The concept, which is similar to the decomposition-and-superposition method [Li, H. D., and L. He. 2005. ASME J ournal of Turbomachinery 127: 589-98.], is illustrated by 3-D computations of a ½-stage transonic compressor.

  8. Understanding North Texas Seismicity: A Joint Analysis of Seismic Data and 3D Pore Pressure Modeling

    NASA Astrophysics Data System (ADS)

    DeShon, H. R.; Hornbach, M. J.; Ellsworth, W. L.; Oldham, H. R.; Hayward, C.; Stump, B. W.; Frohlich, C.; Olson, J. E.; Luetgert, J. H.

    2014-12-01

    In November 2013, a series of earthquakes began along a mapped ancient fault system near Azle, Texas. The Azle events are the third felt earthquake sequence in the Fort Worth (Barnett Shale) Basin since 2008, and several production and injection wells in the area are drilled to depths near the recent seismic activity. Understanding if and/or how injection and removal of fluids in the crystalline crust reactivates faults have important implications for seismology, the energy industry, and society. We assessed whether the Azle earthquakes were induced using a joint analysis of the earthquake data, subsurface geology and fault structure, and 3D pore pressure modeling. Using a 12-station temporary seismic deployment, we have recorded and located >300 events large enough to be recorded on multiple stations and 1000s of events during periods of swarm activity. High-resolution locations and focal mechanisms indicate that events occurred on NE-SW trending, steeply dipping normal faults associated with the southern end of the Newark East Fault Zone with hypocenters between 2-8 km depth. We considered multiple causes that might have changed stress along this system. Earthquakes resulting from natural processes, though perhaps unlikely in this historically inactive region, can be neither ruled out nor confirmed due to lack of information on the natural stress state of these faults. Analysis of lake and groundwater variations near Azle showed that no significant stress changes occurred prior to or during the earthquake sequence. In contrast, analysis of pore-pressure models shows that the combination of formation water production and wastewater injection near the fault could have caused pressure increases that induced earthquakes on near-critically stressed faults.

  9. A Shell/3D Modeling Technique for the Analysis of Delaminated Composite Laminates

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; OBrien, T. Kevin

    2000-01-01

    A shell/3D modeling technique was developed for which a local solid finite element model is used only in the immediate vicinity of the delamination front. The goal was to combine the accuracy of the full three-dimensional solution with the computational efficiency of a shell finite element model. Multi-point constraints provided a kinematically compatible interface between the local 3D model and the global structural model which has been meshed with shell finite elements. Double Cantilever Beam, End Notched Flexure, and Single Leg Bending specimens were analyzed first using full 3D finite element models to obtain reference solutions. Mixed mode strain energy release rate distributions were computed using the virtual crack closure technique. The analyses were repeated using the shell/3D technique to study the feasibility for pure mode I, mode II and mixed mode I/II cases. Specimens with a unidirectional layup and with a multidirectional layup were simulated. For a local 3D model, extending to a minimum of about three specimen thicknesses on either side of the delamination front, the results were in good agreement with mixed mode strain energy release rates obtained from computations where the entire specimen had been modeled with solid elements. For large built-up composite structures the shell/3D modeling technique offers a great potential for reducing the model size, since only a relatively small section in the vicinity of the delamination front needs to be modeled with solid elements.

  10. A Workstation for Interactive Display and Quantitative Analysis of 3-D and 4-D Biomedical Images

    PubMed Central

    Robb, R.A.; Heffeman, P.B.; Camp, J.J.; Hanson, D.P.

    1986-01-01

    The capability to extract objective and quantitatively accurate information from 3-D radiographic biomedical images has not kept pace with the capabilities to produce the images themselves. This is rather an ironic paradox, since on the one hand the new 3-D and 4-D imaging capabilities promise significant potential for providing greater specificity and sensitivity (i.e., precise objective discrimination and accurate quantitative measurement of body tissue characteristics and function) in clinical diagnostic and basic investigative imaging procedures than ever possible before, but on the other hand, the momentous advances in computer and associated electronic imaging technology which have made these 3-D imaging capabilities possible have not been concomitantly developed for full exploitation of these capabilities. Therefore, we have developed a powerful new microcomputer-based system which permits detailed investigations and evaluation of 3-D and 4-D (dynamic 3-D) biomedical images. The system comprises a special workstation to which all the information in a large 3-D image data base is accessible for rapid display, manipulation, and measurement. The system provides important capabilities for simultaneously representing and analyzing both structural and functional data and their relationships in various organs of the body. This paper provides a detailed description of this system, as well as some of the rationale, background, theoretical concepts, and practical considerations related to system implementation. ImagesFigure 5Figure 7Figure 8Figure 9Figure 10Figure 11Figure 12Figure 13Figure 14Figure 15Figure 16

  11. Analysis and Visualization of 3D Motion Data for UPDRS Rating of Patients with Parkinson's Disease.

    PubMed

    Piro, Neltje E; Piro, Lennart K; Kassubek, Jan; Blechschmidt-Trapp, Ronald A

    2016-06-21

    Remote monitoring of Parkinson's Disease (PD) patients with inertia sensors is a relevant method for a better assessment of symptoms. We present a new approach for symptom quantification based on motion data: the automatic Unified Parkinson Disease Rating Scale (UPDRS) classification in combination with an animated 3D avatar giving the neurologist the impression of having the patient live in front of him. In this study we compared the UPDRS ratings of the pronation-supination task derived from: (a) an examination based on video recordings as a clinical reference; (b) an automatically classified UPDRS; and (c) a UPDRS rating from the assessment of the animated 3D avatar. Data were recorded using Magnetic, Angular Rate, Gravity (MARG) sensors with 15 subjects performing a pronation-supination movement of the hand. After preprocessing, the data were classified with a J48 classifier and animated as a 3D avatar. Video recording of the movements, as well as the 3D avatar, were examined by movement disorder specialists and rated by UPDRS. The mean agreement between the ratings based on video and (b) the automatically classified UPDRS is 0.48 and with (c) the 3D avatar it is 0.47. The 3D avatar is similarly suitable for assessing the UPDRS as video recordings for the examined task and will be further developed by the research team.

  12. Performance Analysis of a Low-Cost Triangulation-Based 3d Camera: Microsoft Kinect System

    NASA Astrophysics Data System (ADS)

    . K. Chow, J. C.; Ang, K. D.; Lichti, D. D.; Teskey, W. F.

    2012-07-01

    Recent technological advancements have made active imaging sensors popular for 3D modelling and motion tracking. The 3D coordinates of signalised targets are traditionally estimated by matching conjugate points in overlapping images. Current 3D cameras can acquire point clouds at video frame rates from a single exposure station. In the area of 3D cameras, Microsoft and PrimeSense have collaborated and developed an active 3D camera based on the triangulation principle, known as the Kinect system. This off-the-shelf system costs less than 150 USD and has drawn a lot of attention from the robotics, computer vision, and photogrammetry disciplines. In this paper, the prospect of using the Kinect system for precise engineering applications was evaluated. The geometric quality of the Kinect system as a function of the scene (i.e. variation of depth, ambient light conditions, incidence angle, and object reflectivity) and the sensor (i.e. warm-up time and distance averaging) were analysed quantitatively. This system's potential in human body measurements was tested against a laser scanner and 3D range camera. A new calibration model for simultaneously determining the exterior orientation parameters, interior orientation parameters, boresight angles, leverarm, and object space features parameters was developed and the effectiveness of this calibration approach was explored.

  13. Gait analysis in a pre- and post-ischemic stroke biomedical pig model.

    PubMed

    Duberstein, Kylee Jo; Platt, Simon R; Holmes, Shannon P; Dove, C Robert; Howerth, Elizabeth W; Kent, Marc; Stice, Steven L; Hill, William D; Hess, David C; West, Franklin D

    2014-02-10

    Severity of neural injury including stroke in human patients, as well as recovery from injury, can be assessed through changes in gait patterns of affected individuals. Similar quantification of motor function deficits has been measured in rodent animal models of such injuries. However, due to differences in fundamental structure of human and rodent brains, there is a need to develop a large animal model to facilitate treatment development for neurological conditions. Porcine brain structure is similar to that of humans, and therefore the pig may make a more clinically relevant animal model. The current study was undertaken to determine key gait characteristics in normal biomedical miniature pigs and dynamic changes that occur post-neural injury in a porcine middle cerebral artery (MCA) occlusion ischemic stroke model. Yucatan miniature pigs were trained to walk through a semi-circular track and were recorded with high speed cameras to detect changes in key gait parameters. Analysis of normal pigs showed overall symmetry in hindlimb swing and stance times, forelimb stance time, along with step length, step velocity, and maximum hoof height on both fore and hindlimbs. A subset of pigs were again recorded at 7, 5 and 3 days prior to MCA occlusion and then at 1, 3, 5, 7, 14 and 30 days following surgery. MRI analysis showed that MCA occlusion resulted in significant infarction. Gait analysis indicated that stroke resulted in notable asymmetries in both temporal and spatial variables. Pigs exhibited lower maximum front hoof height on the paretic side, as well as shorter swing time and longer stance time on the paretic hindlimb. These results support that gait analysis of stroke injury is a highly sensitive detection method for changes in gait parameters in pig.

  14. DRAG: a database for recognition and analasys of gait

    NASA Astrophysics Data System (ADS)

    Kuchi, Prem; Hiremagalur, Raghu Ram V.; Huang, Helen; Carhart, Michael; He, Jiping; Panchanathan, Sethuraman

    2003-11-01

    A novel approach is proposed for creating a standardized and comprehensive database for gait analysis. The field of gait analysis is gaining increasing attention for applications such as visual surveillance, human-computer interfaces, and gait recognition and rehabilitation. Numerous algorithms have been developed for analyzing and processing gait data; however, a standard database for their systematic evaluation does not exist. Instead, existing gait databases consist of subsets of kinematic, kinetic, and electromyographic activity recordings by different investigators, at separate laboratories, and under varying conditions. Thus, the existing databases are neither homogenous nor sufficiently populated to statistically validate the algorithms. In this paper, a methodology for creating a database is presented, which can be used as a common ground to test the performance of algorithms that rely upon external marker data, ground reaction loading data, and/or video images. The database consists of: (1) synchronized motion-capture data (3D marker data) obtained using external markers, (2) computed joint angles, and (3) ground reaction loading acquired with plantar pressure insoles. This database could be easily expanded to include synchronized video, which will facilitate further development of video-based algorithms for motion tracking. This eventually could lead to the realization of markerless gait tracking. Such a system would have extensive applications in gait recognition, as well as gait rehabilitation. The entire database (marker, angle, and force data) will be placed in the public domain, and made available for downloads over the World Wide Web.

  15. The CatWalk gait analysis in assessment of both dynamic and static gait changes after adult rat sciatic nerve resection.

    PubMed

    Deumens, Ronald; Jaken, Robby J P; Marcus, Marco A E; Joosten, Elbert A J

    2007-08-15

    Functional repair of neurotmesis has been proven most challenging in regenerative medicine. Progress in this field has shown that functional repair not only requires axon regeneration, but also selectivity in target reinnervation. Although selectivity in target reinnervation still involves relatively unexplored avenues, evidence-based medicine, in the end, requires behavioral proof of repair. Therefore, there is a need for tests assessing behavioral deficits after neurotmesis. To date, behavioral tests for detecting both dynamic and static parameters are limited. The CatWalk gait analysis has been shown to detect a multitude of speed-controlled dynamic and static gait deficits after experimental spinal cord injury. Therefore, we here evaluated its use in detecting both dynamic and static gait deficits after neurotmesis. After rat sciatic nerve resection CatWalk testing was performed for 8 weeks. A large amount of dynamic and static gait parameters were detected to be immediately and severely affected in the ipsilateral paw, sometimes reaching levels of only 15% of those of the unaffected paw. We conclude that the CatWalk objectively detects dynamic and static gait impairments after sciatic nerve resection and future experiments are now required to prove which of these parameters are of particular interest to detect functional repair.

  16. [Applications of 2D and 3D landscape pattern indices in landscape pattern analysis of mountainous area at county level].

    PubMed

    Lu, Chao; Qi, Wei; Li, Le; Sun, Yao; Qin, Tian-Tian; Wang, Na-Na

    2012-05-01

    Landscape pattern indices are the commonly used tools for the quantitative analysis of landscape pattern. However, the traditional 2D landscape pattern indices neglect the effects of terrain on landscape, existing definite limitations in quantitatively describing the landscape patterns in mountains areas. Taking the Qixia City, a typical mountainous and hilly region in Shandong Province of East China, as a case, this paper compared the differences between 2D and 3D landscape pattern indices in quantitatively describing the landscape patterns and their dynamic changes in mountainous areas. On the basis of terrain structure analysis, a set of landscape pattern indices were selected, including area and density (class area and mean patch size), edge and shape (edge density, landscape shape index, and fractal dimension of mean patch), diversity (Shannon's diversity index and evenness index) , and gathering and spread (contagion index). There existed obvious differences between the 3D class area, mean patch area, and edge density and the corresponding 2D indices, but no significant differences between the 3D landscape shape index, fractal dimension of mean patch, and Shannon' s diversity index and evenness index and the corresponding 2D indices. The 3D contagion index and 2D contagion index had no difference. Because the 3D landscape pattern indices were calculated by using patch surface area and surface perimeter whereas the 2D landscape pattern indices were calculated by adopting patch projective area and projective perimeter, the 3D landscape pattern indices could be relative accurate and efficient in describing the landscape area, density and borderline, in mountainous areas. However, there were no distinct differences in describing landscape shape, diversity, and gathering and spread between the 3D and 2D landscape pattern indices. Generally, by introducing 3D landscape pattern indices to topographic pattern, the description of landscape pattern and its dynamic

  17. The development of a tool for assessing the quality of closed circuit camera footage for use in forensic gait analysis.

    PubMed

    Birch, Ivan; Vernon, Wesley; Walker, Jeremy; Saxelby, Jai

    2013-10-01

    Gait analysis from closed circuit camera footage is now commonly used as evidence in criminal trials. The biomechanical analysis of human gait is a well established science in both clinical and laboratory settings. However, closed circuit camera footage is rarely of the quality of that taken in the more controlled clinical and laboratory environments. The less than ideal quality of much of this footage for use in gait analysis is associated with a range of issues, the combination of which can often render the footage unsuitable for use in gait analysis. The aim of this piece of work was to develop a tool for assessing the suitability of closed circuit camera footage for the purpose of forensic gait analysis. A Delphi technique was employed with a small sample of expert forensic gait analysis practitioners, to identify key quality elements of CCTV footage used in legal proceedings. Five elements of the footage were identified and then subdivided into 15 contributing sub-elements, each of which was scored using a 5-point Likert scale. A Microsoft Excel worksheet was developed to calculate automatically an overall score from the fifteen sub-element scores. Five expert witnesses experienced in using CCTV footage for gait analysis then trialled the prototype tool on current case footage. A repeatability study was also undertaken using standardized CCTV footage. The results showed the tool to be a simple and repeatable means of assessing the suitability of closed circuit camera footage for use in forensic gait analysis. The inappropriate use of poor quality footage could lead to challenges to the practice of forensic gait analysis. All parties involved in criminal proceedings must therefore understand the fitness for purpose of any footage used. The development of this tool could offer a method of achieving this goal, and help to assure the continued role of forensic gait analysis as an aid to the identification process.

  18. Pep-3D-Search: a method for B-cell epitope prediction based on mimotope analysis

    PubMed Central

    Huang, Yan Xin; Bao, Yong Li; Guo, Shu Yan; Wang, Yan; Zhou, Chun Guang; Li, Yu Xin

    2008-01-01

    Background The prediction of conformational B-cell epitopes is one of the most important goals in immunoinformatics. The solution to this problem, even if approximate, would help in designing experiments to precisely map the residues of interaction between an antigen and an antibody. Consequently, this area of research has received considerable attention from immunologists, structural biologists and computational biologists. Phage-displayed random peptide libraries are powerful tools used to obtain mimotopes that are selected by binding to a given monoclonal antibody (mAb) in a similar way to the native epitope. These mimotopes can be considered as functional epitope mimics. Mimotope analysis based methods can predict not only linear but also conformational epitopes and this has been the focus of much research in recent years. Though some algorithms based on mimotope analysis have been proposed, the precise localization of the interaction site mimicked by the mimotopes is still a challenging task. Results In this study, we propose a method for B-cell epitope prediction based on mimotope analysis called Pep-3D-Search. Given the 3D structure of an antigen and a set of mimotopes (or a motif sequence derived from the set of mimotopes), Pep-3D-Search can be used in two modes: mimotope or motif. To evaluate the performance of Pep-3D-Search to predict epitopes from a set of mimotopes, 10 epitopes defined by crystallography were compared with the predicted results from a Pep-3D-Search: the average Matthews correlation oefficient (MCC), sensitivity and precision were 0.1758, 0.3642 and 0.6948. Compared with other available prediction algorithms, Pep-3D-Search showed comparable MCC, specificity and precision, and could provide novel, rational results. To verify the capability of Pep-3D-Search to align a motif sequence to a 3D structure for predicting epitopes, 6 test cases were used. The predictive performance of Pep-3D-Search was demonstrated to be superior to that of other

  19. Inertial sensor based and shoe size independent gait analysis including heel and toe clearance estimation.

    PubMed

    Kanzler, Christoph M; Barth, Jens; Rampp, Alexander; Schlarb, Heiko; Rott, Franz; Klucken, Jochen; Eskofier, Bjoern M

    2015-01-01

    Falls are a major cause for morbidity and mortality in the ageing society. Inertial sensor based gait assessment including the analysis of the heel and toe clearance can be an indicator for the risk of falling. This paper presents a method for calculating the continuous heel and toe clearance without the knowledge of the shoe dimensions as well as the foot angle in the sagittal plane. These gait parameters were validated using an optical motion capture system. 20 healthy subjects from 3 different age groups (young, mid age, old) performed gait trials with different stride lengths and stride velocities. We obtained low mean absolute errors, low standard deviations and high Pearson correlations (0.91-0.99) for all gait parameters. In summary, we implemented a viable algorithm for the calculation of the heel and toe clearance without knowing the shoe dimensions as well as the foot angle in sagittal plane. We conclude that the given method is applicable for a mobile and unobtrusive gait assessment for healthy subjects from all age classes.

  20. 3D micro profile measurement with the method of spatial frequency domain analysis

    NASA Astrophysics Data System (ADS)

    Xu, Yongxiang

    2015-10-01

    3D micro profiles are often needed for measurement in many fields, e.g., binary optics, electronic industry, mechanical manufacturing, aeronautic and space industry, etc. In the case where height difference between two neighboring points of a test profile is equal to or greater than λ / 4, microscopic interferometry based on laser source will no longer be applicable because of the uncertainty in phase unwrapping. As white light possesses the characteristic of interference length approximate to zero, applying it for micro profilometry can avoid the trouble and can yield accurate results. Using self-developed Mirau-type scanning interference microscope, a step-like sample was tested twice, with 128 scanning interferograms recorded for each test. To process each set of the interferograms, the method of spatial frequency domain analysis was adopted. That is, for each point, by use of Furrier transform, white-light interference intensities were decomposed in spatial frequency domain, thus obtaining phase values corresponding to different wavenumbers; by using least square fitting on phases and wave numbers, a group-velocity OPD was gained for the very point; and finally in terms of the relation between relative height and the group-velocity OPD, the profile of the test sample was obtained. Two tests yielded same profile result for the sample, and step heights obtained were 50.88 nm and 50.94 nm, respectively. Meantime, the sample was also measured with a Zygo Newview 7200 topography instrument, with same profile result obtained and step height differing by 0.9 nm. In addition, data processing results indicate that chromatic dispersion equal to and higher than 2nd order is negligible when applying spatial frequency domain analysis method.

  1. 3-D segmentation and quantitative analysis of inner and outer walls of thrombotic abdominal aortic aneurysms

    NASA Astrophysics Data System (ADS)

    Lee, Kyungmoo; Yin, Yin; Wahle, Andreas; Olszewski, Mark E.; Sonka, Milan

    2008-03-01

    An abdominal aortic aneurysm (AAA) is an area of a localized widening of the abdominal aorta, with a frequent presence of thrombus. A ruptured aneurysm can cause death due to severe internal bleeding. AAA thrombus segmentation and quantitative analysis are of paramount importance for diagnosis, risk assessment, and determination of treatment options. Until now, only a small number of methods for thrombus segmentation and analysis have been presented in the literature, either requiring substantial user interaction or exhibiting insufficient performance. We report a novel method offering minimal user interaction and high accuracy. Our thrombus segmentation method is composed of an initial automated luminal surface segmentation, followed by a cost function-based optimal segmentation of the inner and outer surfaces of the aortic wall. The approach utilizes the power and flexibility of the optimal triangle mesh-based 3-D graph search method, in which cost functions for thrombus inner and outer surfaces are based on gradient magnitudes. Sometimes local failures caused by image ambiguity occur, in which case several control points are used to guide the computer segmentation without the need to trace borders manually. Our method was tested in 9 MDCT image datasets (951 image slices). With the exception of a case in which the thrombus was highly eccentric, visually acceptable aortic lumen and thrombus segmentation results were achieved. No user interaction was used in 3 out of 8 datasets, and 7.80 +/- 2.71 mouse clicks per case / 0.083 +/- 0.035 mouse clicks per image slice were required in the remaining 5 datasets.

  2. Mutational analysis of the complement receptor type 2 (CR2/CD21)-C3d interaction reveals a putative charged SCR1 binding site for C3d.

    PubMed

    Hannan, Jonathan P; Young, Kendra A; Guthridge, Joel M; Asokan, Rengasamy; Szakonyi, Gerda; Chen, Xiaojiang S; Holers, V Michael

    2005-02-25

    We have characterized the interaction between the first two short consensus repeats (SCR1-2) of complement receptor type 2 (CR2, CD21) and C3d in solution, by utilising the available crystal structures of free and C3d-bound forms of CR2 to create a series of informative mutations targeting specific areas of the CR2-C3d complex. Wild-type and mutant forms of CR2 were expressed on the surface of K562 erythroleukemia cells and their binding ability assessed using C3dg-biotin tetramers complexed to fluorochrome conjugated streptavidin and measured by flow cytometry. Mutations directed at the SCR2-C3d interface (R83A, R83E, G84Y) were found to strongly disrupt C3dg binding, supporting the conclusion that the SCR2 interface reflected in the crystal structure is correct. Previous epitope and peptide mapping studies have also indicated that the PILN11GR13IS sequence of the first inter-cysteine region of SCR1 is essential for the binding of iC3b. Mutations targeting residues within or in close spatial proximity to this area (N11A, N11E, R13A, R13E, Y16A, S32A, S32E), and a number of other positively charged residues located primarily on a contiguous face of SCR1 (R28A, R28E, R36A, R36E, K41A, K41E, K50A, K50E, K57A, K57E, K67A, K67E), have allowed us to reassess those regions on SCR1 that are essential for CR2-C3d binding. The nature of this interaction and the possibility of a direct SCR1-C3d association are discussed extensively. Finally, a D52N mutant was constructed introducing an N-glycosylation sequence at an area central to the CR2 dimer interface. This mutation was designed to disrupt the CR2-C3d interaction, either directly through steric inhibition, or indirectly through disruption of a physiological dimer. However, no difference in C3dg binding relative to wild-type CR2 could be observed for this mutant, suggesting that the dimer may only be found in the crystal form of CR2.

  3. Validation of the kinect for gait analysis using the GAITRite walkway.

    PubMed

    Baldewijns, Greet; Verheyden, Geert; Vanrumste, Bart; Croonenborghs, Tom

    2014-01-01

    Accurate, non-intrusive and straightforward techniques for gait quality analysis can provide important information concerning the fall risk of a person. For this purpose an algorithm was developed which can measure step length and step time using the Kinect depth image. The validity of the measured step length and time is determined using the GAITRite walkway as a ground truth. The results of this validation confirm that the Kinect is well-suited for determining general parameters of a walking sequence (a Spearmans Correlation Coefficient (SCC) of 0.94 for average step length and 0.75 for average step time per walk), but we furthermore show that determining accurate results for single steps is more difficult (SCC of 0.74 for step length and 0.43 for step time for each step), making it harder to measure more complex gait parameters such as e.g. gait symmetry.

  4. Clinical gait analysis for amputees: innovation wishlist and the perspectives offered by the outwalk protocol.

    PubMed

    Cutti, Andrea Giovanni; Raggi, Michele; Andreoni, Giuseppe; Sacchetti, Rinaldo

    2015-01-01

    Clinical gait analysis (CGA) has shown potentials for the prosthetics field and has been found effective for scientific purposes and to design general rehabilitation models. However, intrinsic limitations of the "artificial" laboratory environment usually result in recording performances not representative patients' real-life gait. In order to promote the diffusion of CGA in the clinical decision-making process, a framework for developing novel, more ecological CGA applications is presented. Moreover, the Outwalk protocol, based on wearable sensors and developed within this framework guidelines, is described and validated for its inter-rater agreement on a population of transtibial amputees walking in a real-life scenario. Results show the possibility of drawing precise conclusions over different aspects of amputees' gait and prostheses' performance in every-day life conditions.

  5. Difference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis.

    PubMed

    Thengumpallil, Sheeba; Smith, Kathleen; Monnin, Pascal; Bourhis, Jean; Bochud, François; Moeckli, Raphaël

    2016-11-08

    The study was to describe and to compare the performance of 3D and 4D CBCT imaging modalities by measuring and analyzing the delivered dose and the image quality. The 3D (Chest) and 4D (Symmetry) CBCT Elekta XVI lung IGRT protocols were analyzed. Dose profiles were measured with TLDs inside a dedicated phantom. The dosimetric indicator cone-beam dose index (CBDI) was evaluated. The image quality analysis was performed by assessing the contrast transfer function (CTF), the noise power spectrum (NPS) and the noise-equivalent quanta (NEQ). Artifacts were also evaluated by simulating irregular breathing variations. The two imaging modalities showed different dose distributions within the phantom. At the center, the 3D CBCT delivered twice the dose of the 4D CBCT. The CTF was strongly reduced by motion compared to static conditions, resulting in a CTF reduction of 85% for the 3D CBCT and 65% for the 4D CBCT. The amplitude of the NPS was two times higher for the 4D CBCT than for the 3D CBCT. In the presence of motion, the NEQ of the 4D CBCT was 50% higher than the 3D CBCT. In the presence of breathing irregularities, the 4D CBCT protocol was mainly affected by view-aliasing artifacts, which were typically cone-beam artifacts, while the 3D CBCT protocol was mainly affected by duplication artifacts. The results showed that the 4D CBCT ensures a reasonable dose and better image quality when mov-ing targets are involved compared to 3D CBCT. Therefore, 4D CBCT is a reliable imaging modality for lung free-breathing radiation therapy.

  6. Micro-well arrays for 3D shape control and high resolution analysis of single cells.

    PubMed

    Ochsner, Mirjam; Dusseiller, Marc R; Grandin, H Michelle; Luna-Morris, Sheila; Textor, Marcus; Vogel, Viola; Smith, Michael L

    2007-08-01

    In addition to rigidity, matrix composition, and cell shape, dimensionality is now considered an important property of the cell microenvironment which directs cell behavior. However, available tools for cell culture in two-dimensional (2D) versus three-dimensional (3D) environments are difficult to compare, and no tools exist which provide 3D shape control of single cells. We developed polydimethylsiloxane (PDMS) substrates for the culture of single cells in 3D arrays which are compatible with high-resolution microscopy. Cell adhesion was limited to within microwells by passivation of the flat upper surface through 'wet-printing' of a non-fouling polymer and backfilling of the wells with specific adhesive proteins or lipid bilayers. Endothelial cells constrained within microwells were viable, and intracellular features could be imaged with high resolution objectives. Finally, phalloidin staining of actin stress fibers showed that the cytoskeleton of cells in microwells was 3D and not limited to the cell-substrate interface. Thus, microwells can be used to produce microenvironments for large numbers of single cells with 3D shape control and can be added to a repertoire of tools which are ever more sought after for both fundamental biological studies as well as high throughput cell screening assays.

  7. Automatic 3D Cell Analysis in High-Throughput Microarray Using Micropillar and Microwell Chips.

    PubMed

    Lee, Dong Woo; Lee, Moo-Yeal; Ku, Bosung; Nam, Do-Hyun

    2015-10-01

    Area-based and intensity-based 3D cell viability measurement methods are compared in high-throughput screening in order to analyze their effects on the assay results (doubling time and IC50) and their repeatability. Many other 3D cell-based high-throughput screening platforms had been previously introduced, but these had not clearly addressed the effects of the two methods on the assay results and assay repeatability. In this study, the optimal way to analyze 3D cultured cells is achieved by comparing day-to-day data of doubling times and IC50 values obtained from the two methods. In experiments, the U251 cell line is grown in chips. The doubling time, based on the area of the 3D cells, was 27.8 ± 1.8 h (standard deviation: 6.6%) and 27.8 ± 3.8 h (standard deviation: 13.7%) based on the intensity of the 3D cells. The doubling time calculated by area shows a smaller standard deviation than one calculated by intensity. IC50 values calculated by both methods are very similar. The standard deviations of IC50 values for the two methods were within ± 3-fold. The IC50 variations of the 12 compounds were similar regardless of the viability measurement methods and were highly related to the shape of the dose-response curves.

  8. Gene3D: Multi-domain annotations for protein sequence and comparative genome analysis.

    PubMed

    Lees, Jonathan G; Lee, David; Studer, Romain A; Dawson, Natalie L; Sillitoe, Ian; Das, Sayoni; Yeats, Corin; Dessailly, Benoit H; Rentzsch, Robert; Orengo, Christine A

    2014-01-01

    Gene3D (http://gene3d.biochem.ucl.ac.uk) is a database of protein domain structure annotations for protein sequences. Domains are predicted using a library of profile HMMs from 2738 CATH superfamilies. Gene3D assigns domain annotations to Ensembl and UniProt sequence sets including >6000 cellular genomes and >20 million unique protein sequences. This represents an increase of 45% in the number of protein sequences since our last publication. Thanks to improvements in the underlying data and pipeline, we see large increases in the domain coverage of sequences. We have expanded this coverage by integrating Pfam and SUPERFAMILY domain annotations, and we now resolve domain overlaps to provide highly comprehensive composite multi-domain architectures. To make these data more accessible for comparative genome analyses, we have developed novel search algorithms for searching genomes to identify related multi-domain architectures. In addition to providing domain family annotations, we have now developed a pipeline for 3D homology modelling of domains in Gene3D. This has been applied to the human genome and will be rolled out to other major organisms over the next year.

  9. Evaluation by quantitative image analysis of anticancer drug activity on multicellular spheroids grown in 3D matrices

    PubMed Central

    Gomes, Aurélie; Russo, Adrien; Vidal, Guillaume; Demange, Elise; Pannetier, Pauline; Souguir, Zied; Lagarde, Jean-Michel; Ducommun, Bernard; Lobjois, Valérie

    2016-01-01

    Pharmacological evaluation of anticancer drugs using 3D in vitro models provides invaluable information for predicting in vivo activity. Artificial matrices are currently available that scale up and increase the power of such 3D models. The aim of the present study was to propose an efficient and robust imaging and analysis pipeline to assess with quantitative parameters the efficacy of a particular cytotoxic drug. HCT116 colorectal adenocarcinoma tumor cell multispheres were grown in a 3D physiological hyaluronic acid matrix. 3D microscopy was performed with structured illumination, whereas image processing and feature extraction were performed with custom analysis tools. This procedure makes it possible to automatically detect spheres in a large volume of matrix in 96-well plates. It was used to evaluate drug efficacy in HCT116 spheres treated with different concentrations of topotecan, a DNA topoisomerase inhibitor. Following automatic detection and quantification, changes in cluster size distribution with a topotecan concentration-dependent increase of small clusters according to drug cytotoxicity were observed. Quantitative image analysis is thus an effective means to evaluate and quantify the cytotoxic and cytostatic activities of anticancer drugs on 3D multicellular models grown in a physiological matrix. PMID:28105152

  10. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture

    NASA Astrophysics Data System (ADS)

    Apostol, Lian; Peyrin, Francoise; Yot, Sophie; Basset, Olivier; Odet, Christophe; Tabary, Joachim; Dinten, Jean-Marc; Boller, Elodie; Boudousq, Vincent; Kotzki, Pierre-Olivier

    2004-05-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography (μCT). In vivo, techniques based on high-resolution s-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships betweeen 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray μCT at the ESRF. The 3D digital imagees were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identfying the most relevant 2D texture parameters.

  11. 3D analysis of condylar remodelling and skeletal relapse following bilateral sagittal split advancement osteotomies.

    PubMed

    Xi, Tong; Schreurs, Ruud; van Loon, Bram; de Koning, Martien; Bergé, Stefaan; Hoppenreijs, Theo; Maal, Thomas

    2015-05-01

    A major concern in mandibular advancement surgery using bilateral sagittal split osteotomies (BSSO) is potential postoperative relapse. Although the role of postoperative changes in condylar morphology on skeletal relapse was reported in previous studies, no study so far has objectified the precise changes of the condylar volume. The aim of the present study was to quantify the postoperative volume changes of condyles and its role on skeletal stability following BSSO mandibular advancement surgery. A total of 56 patients with mandibular hypoplasia who underwent BSSO advancement surgery were prospectively enrolled into the study. A cone beam computed tomography (CBCT) scan was acquired preoperatively, at 1 week postoperatively and at 1 year postoperatively. After the segmentation of the facial skeleton and condyles, three-dimensional cephalometry and condylar volume analysis were performed. The mean mandibular advancement was 4.6 mm, and the mean postoperative relapse was 0.71 mm. Of 112 condyles, 55% showed a postoperative decrease in condylar volume, with a mean reduction of 105 mm(3) (6.1% of the original condylar volume). The magnitude of condylar remodelling (CR) was significantly correlated with skeletal relapse (p = 0.003). Patients with a CR greater than 17% of the original condylar volume exhibited relapse as seen in progressive condylar resorption. Female patients with a high mandibular angle who exhibited postoperative CR were particularly at risk for postoperative relapse. Gender, preoperative condylar volume, and downward displacement of pogonion at surgery were prognostic factors for CR (r(2) = 21%). It could be concluded that the condylar volume can be applied as a useful 3D radiographic parameter for the diagnosis and follow-up of postoperative skeletal relapse and progressive condylar resorption.

  12. Analysis of Hyoid-Larynx Complex Using 3D Geometric Morphometrics.

    PubMed

    Loth, Anthony; Corny, Julien; Santini, Laure; Dahan, Laurie; Dessi, Patrick; Adalian, Pascal; Fakhry, Nicolas

    2015-06-01

    The aim of this study was to obtain a quantitative anatomical description of the hyoid bone-larynx complex using modern 3D reconstruction tools. The study was conducted on 104 bones from CT scan images of living adult subjects. Three-dimensional reconstructions were created from CT scan images using AVIZO 6.2 software package. A study of this complex was carried out using metric and morphological analyses. Characteristics of the hyoid bone and larynx were highly heterogeneous and were closely linked with the sex, height, and weight of the individuals. Height and width of larynx were significantly greater in men than in women (24.99 vs. 17.3 mm, p ≤ 0.05 and 46.75 vs. 41.07, p ≤ 0.05), whereas the thyroid angle was larger in females (81.12° vs. 74.48°, p ≤ 0.05). There was a significant correlation between the height and weight of subjects and different measurements of the hyoid-larynx complex. (Pearson's coefficient correlation r = 0.42, p ≤ 0.05 between the height of thyroid ala and the height of subjects and r = 0.1, p ≤ 0.05 between the height of thyroid ala and the weight of subjects). Shape and size analysis of the hyoid-larynx complex showed the existence of a significant sexual dimorphism and high interindividual heterogeneity depending to patient morphology. These results encourage us to go further with functional and imaging correlations.

  13. Quantitative analysis of 3D extracellular matrix remodelling by pancreatic stellate cells

    PubMed Central

    Robinson, Benjamin K.; Cortes, Ernesto; Rice, Alistair J.; Sarper, Muge

    2016-01-01

    ABSTRACT Extracellular matrix (ECM) remodelling is integral to numerous physiological and pathological processes in biology, such as embryogenesis, wound healing, fibrosis and cancer. Until recently, most cellular studies have been conducted on 2D environments where mechanical cues significantly differ from physiologically relevant 3D environments, impacting cellular behaviour and masking the interpretation of cellular function in health and disease. We present an integrated methodology where cell-ECM interactions can be investigated in 3D environments via ECM remodelling. Monitoring and quantification of collagen-I structure in remodelled matrices, through designated algorithms, show that 3D matrices can be used to correlate remodelling with increased ECM stiffness observed in fibrosis. Pancreatic stellate cells (PSCs) are the key effectors of the stromal fibrosis associated to pancreatic cancer. We use PSCs to implement our methodology and demonstrate that PSC matrix remodelling capabilities depend on their contractile machinery and β1 integrin-mediated cell-ECM attachment. PMID:27170254

  14. Nanoscale Analysis of a Hierarchical Hybrid Solar Cell in 3D

    PubMed Central

    Divitini, Giorgio; Stenzel, Ole; Ghadirzadeh, Ali; Guarnera, Simone; Russo, Valeria; Casari, Carlo S; Bassi, Andrea Li; Petrozza, Annamaria; Di Fonzo, Fabio; Schmidt, Volker; Ducati, Caterina

    2014-01-01

    A quantitative method for the characterization of nanoscale 3D morphology is applied to the investigation of a hybrid solar cell based on a novel hierarchical nanostructured photoanode. A cross section of the solar cell device is prepared by focused ion beam milling in a micropillar geometry, which allows a detailed 3D reconstruction of the titania photoanode by electron tomography. It is found that the hierarchical titania nanostructure facilitates polymer infiltration, thus favoring intermixing of the two semiconducting phases, essential for charge separation. The 3D nanoparticle network is analyzed with tools from stochastic geometry to extract information related to the charge transport in the hierarchical solar cell. In particular, the experimental dataset allows direct visualization of the percolation pathways that contribute to the photocurrent. PMID:25834481

  15. 3D numerical simulation analysis of passive drag near free surface in swimming

    NASA Astrophysics Data System (ADS)

    Zhan, Jie-min; Li, Tian-zeng; Chen, Xue-bin; Li, Yok-sheung; Wai, Wing-hong Onyx

    2015-04-01

    The aim of this work is to build a 3D numerical model to study the characteristics of passive drag on competitive swimmers taking into account the impact of the free surface. This model solves the 3D incompressible Navier-Stokes equations using RNG k- ɛ turbulence closure. The volume of fluid (VOF) method is used to locate the free surface. The 3D virtual model is created by Computer Aided Industrial Design (CAID) software, Rhinoceros. Firstly, a specific posture of swimming is studied. The simulation results are in good agreement with the data from mannequin towing experiments. The effects of a swimmer's arms and legs positions on swimming performance are then studied. Finally, it is demonstrated that the present method is capable of simulating gliding near the free surface.

  16. Stereoscopic motion analysis in densely packed clusters: 3D analysis of the shimmering behaviour in Giant honey bees

    PubMed Central

    2011-01-01

    Background The detailed interpretation of mass phenomena such as human escape panic or swarm behaviour in birds, fish and insects requires detailed analysis of the 3D movements of individual participants. Here, we describe the adaptation of a 3D stereoscopic imaging method to measure the positional coordinates of individual agents in densely packed clusters. The method was applied to study behavioural aspects of shimmering in Giant honeybees, a collective defence behaviour that deters predatory wasps by visual cues, whereby individual bees flip their abdomen upwards in a split second, producing Mexican wave-like patterns. Results Stereoscopic imaging provided non-invasive, automated, simultaneous, in-situ 3D measurements of hundreds of bees on the nest surface regarding their thoracic position and orientation of the body length axis. Segmentation was the basis for the stereo matching, which defined correspondences of individual bees in pairs of stereo images. Stereo-matched "agent bees" were re-identified in subsequent frames by the tracking procedure and triangulated into real-world coordinates. These algorithms were required to calculate the three spatial motion components (dx: horizontal, dy: vertical and dz: towards and from the comb) of individual bees over time. Conclusions The method enables the assessment of the 3D positions of individual Giant honeybees, which is not possible with single-view cameras. The method can be applied to distinguish at the individual bee level active movements of the thoraces produced by abdominal flipping from passive motions generated by the moving bee curtain. The data provide evidence that the z-deflections of thoraces are potential cues for colony-intrinsic communication. The method helps to understand the phenomenon of collective decision-making through mechanoceptive synchronization and to associate shimmering with the principles of wave propagation. With further, minor modifications, the method could be used to study

  17. F3D Image Processing and Analysis for Many - and Multi-core Platforms

    SciTech Connect

    2014-10-01

    F3D is written in OpenCL, so it achieve[sic] platform-portable parallelism on modern mutli-core CPUs and many-core GPUs. The interface and mechanims to access F3D core are written in Java as a plugin for Fiji/ImageJ to deliver several key image-processing algorithms necessary to remove artifacts from micro-tomography data. The algorithms consist of data parallel aware filters that can efficiently utilizes[sic] resources and can work on out of core datasets and scale efficiently across multiple accelerators. Optimizing for data parallel filters, streaming out of core datasets, and efficient resource and memory and data managements over complex execution sequence of filters greatly expedites any scientific workflow with image processing requirements. F3D performs several different types of 3D image processing operations, such as non-linear filtering using bilateral filtering and/or median filtering and/or morphological operators (MM). F3D gray-level MM operators are one-pass constant time methods that can perform morphological transformations with a line-structuring element oriented in discrete directions. Additionally, MM operators can be applied to gray-scale images, and consist of two parts: (a) a reference shape or structuring element, which is translated over the image, and (b) a mechanism, or operation, that defines the comparisons to be performed between the image and the structuring element. This tool provides a critical component within many complex pipelines such as those for performing automated segmentation of image stacks. F3D is also called a "descendent" of Quant-CT, another software we developed in the past. These two modules are to be integrated in a next version. Further details were reported in: D.M. Ushizima, T. Perciano, H. Krishnan, B. Loring, H. Bale, D. Parkinson, and J. Sethian. Structure recognition from high-resolution images of ceramic composites. IEEE International Conference on Big Data, October 2014.

  18. Quantitative