Science.gov

Sample records for 3d mri based

  1. 3D MRI-based tumor delineation of ocular melanoma and its comparison with conventional techniques.

    PubMed

    Daftari, Inder k; Aghaian, Elsa; O'Brien, Joan M; Dillon, William; Phillips, Theodore L

    2005-11-01

    The aim of this study is to (1) compare the delineation of the tumor volume for ocular melanoma on high-resolution three-dimensional (3D) T2-weighted fast spin echo magnetic resonance imaging (MRI) images with conventional techniques of A- and B-scan ultrasound, transcleral illumination, and placement of tantalum markers around tumor base and (2) to evaluate whether the surgically placed marker ring tumor delineation can be replaced by 3D MRI based tumor delineation. High-resolution 3D T2-weighted fast spin echo (3D FSE) MRI scans were obtained for 60 consecutive ocular melanoma patients using a 1.5 T MRI (GE Medical Systems, Milwaukee, WI), in a standard head coil. These patients were subsequently treated with proton beam therapy at the UC Davis Cyclotron, Davis, CA. The tumor was delineated by placement of tantalum rings (radio-opaque markers) around the tumor periphery as defined by pupillary transillumination during surgery. A point light source, placed against the sclera, was also used to confirm ring agreement with indirect ophthalmoscopy. When necessary, intraoperative ultrasound was also performed. The patients were planned using EYEPLAN software and the tumor volumes were obtained. For analysis, the tumors were divided into four categories based on tumor height and basal diameter. In order to assess the impact of high-resolution 3D T2 FSE MRI, the tumor volumes were outlined on the MRI scans by two independent observers and the tumor volumes calculated for each patient. Six (10%) of 60 patients had tumors, which were not visible on 3D MRI images. These six patients had tumors with tumor heights < or = 3 mm. A small intraobserver variation with a mean of (-0.22 +/- 4)% was seen in tumor volumes delineated by 3D T2 FSE MR images. The ratio of tumor volumes measured on MRI to EYEPLAN for the largest to the smallest tumor volumes varied between 0.993 and 1.02 for 54 patients. The tumor volumes measured directly on 3D T2 FSE MRI ranged from 4.03 to 0.075 cm3

  2. 3D MRI-based tumor delineation of ocular melanoma and its comparison with conventional techniques

    SciTech Connect

    Daftari, Inder k; Aghaian, Elsa; O'Brien, Joan M.; Dillon, William; Phillips, Theodore L.

    2005-11-15

    The aim of this study is to (1) compare the delineation of the tumor volume for ocular melanoma on high-resolution three-dimensional (3D) T2-weighted fast spin echo magnetic resonance imaging (MRI) images with conventional techniques of A- and B-scan ultrasound, transcleral illumination, and placement of tantalum markers around tumor base and (2) to evaluate whether the surgically placed marker ring tumor delineation can be replaced by 3D MRI based tumor delineation. High-resolution 3D T2-weighted fast spin echo (3D FSE) MRI scans were obtained for 60 consecutive ocular melanoma patients using a 1.5 T MRI (GE Medical Systems, Milwaukee, WI), in a standard head coil. These patients were subsequently treated with proton beam therapy at the UC Davis Cyclotron, Davis, CA. The tumor was delineated by placement of tantalum rings (radio-opaque markers) around the tumor periphery as defined by pupillary transillumination during surgery. A point light source, placed against the sclera, was also used to confirm ring agreement with indirect ophthalmoscopy. When necessary, intraoperative ultrasound was also performed. The patients were planned using EYEPLAN software and the tumor volumes were obtained. For analysis, the tumors were divided into four categories based on tumor height and basal diameter. In order to assess the impact of high-resolution 3D T2 FSE MRI, the tumor volumes were outlined on the MRI scans by two independent observers and the tumor volumes calculated for each patient. Six (10%) of 60 patients had tumors, which were not visible on 3D MRI images. These six patients had tumors with tumor heights {<=}3 mm. A small intraobserver variation with a mean of (-0.22{+-}4)% was seen in tumor volumes delineated by 3D T2 FSE MR images. The ratio of tumor volumes measured on MRI to EYEPLAN for the largest to the smallest tumor volumes varied between 0.993 and 1.02 for 54 patients. The tumor volumes measured directly on 3D T2 FSE MRI ranged from 4.03 to 0.075 cm{sup 3

  3. Improved 3D wavelet-based de-noising of fMRI data

    NASA Astrophysics Data System (ADS)

    Khullar, Siddharth; Michael, Andrew M.; Correa, Nicolle; Adali, Tulay; Baum, Stefi A.; Calhoun, Vince D.

    2011-03-01

    Functional MRI (fMRI) data analysis deals with the problem of detecting very weak signals in very noisy data. Smoothing with a Gaussian kernel is often used to decrease noise at the cost of losing spatial specificity. We present a novel wavelet-based 3-D technique to remove noise in fMRI data while preserving the spatial features in the component maps obtained through group independent component analysis (ICA). Each volume is decomposed into eight volumetric sub-bands using a separable 3-D stationary wavelet transform. Each of the detail sub-bands are then treated through the main denoising module. This module facilitates computation of shrinkage factors through a hierarchical framework. It utilizes information iteratively from the sub-band at next higher level to estimate denoised coefficients at the current level. These de-noised sub-bands are then reconstructed back to the spatial domain using an inverse wavelet transform. Finally, the denoised group fMRI data is analyzed using ICA where the data is decomposed in to clusters of functionally correlated voxels (spatial maps) as indicators of task-related neural activity. The proposed method enables the preservation of shape of the actual activation regions associated with the BOLD activity. In addition it is able to achieve high specificity as compared to the conventionally used FWHM (full width half maximum) Gaussian kernels for smoothing fMRI data.

  4. Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    PubMed

    Odille, Freddy; Bustin, Aurélien; Liu, Shufang; Chen, Bailiang; Vuissoz, Pierre-André; Felblinger, Jacques; Bonnemains, Laurent

    2017-10-02

    Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow. Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free-breathing in SAX and long-axis (LAX) orientations) using nonrigid motion correction (cine-GRICS method) and super-resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B-spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours. All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3-6 sparse slices instead of 8-10 contiguous SAX slices). When compared to independent phase-contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of -1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end-diastolic volumes, end-systolic volumes, and ejection fractions). The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  5. Wavelet-based fMRI analysis: 3-D denoising, signal separation, and validation metrics.

    PubMed

    Khullar, Siddharth; Michael, Andrew; Correa, Nicolle; Adali, Tulay; Baum, Stefi A; Calhoun, Vince D

    2011-02-14

    We present a novel integrated wavelet-domain based framework (w-ICA) for 3-D denoising functional magnetic resonance imaging (fMRI) data followed by source separation analysis using independent component analysis (ICA) in the wavelet domain. We propose the idea of a 3-D wavelet-based multi-directional denoising scheme where each volume in a 4-D fMRI data set is sub-sampled using the axial, sagittal and coronal geometries to obtain three different slice-by-slice representations of the same data. The filtered intensity value of an arbitrary voxel is computed as an expected value of the denoised wavelet coefficients corresponding to the three viewing geometries for each sub-band. This results in a robust set of denoised wavelet coefficients for each voxel. Given the de-correlated nature of these denoised wavelet coefficients, it is possible to obtain more accurate source estimates using ICA in the wavelet domain. The contributions of this work can be realized as two modules: First, in the analysis module we combine a new 3-D wavelet denoising approach with signal separation properties of ICA in the wavelet domain. This step helps obtain an activation component that corresponds closely to the true underlying signal, which is maximally independent with respect to other components. Second, we propose and describe two novel shape metrics for post-ICA comparisons between activation regions obtained through different frameworks. We verified our method using simulated as well as real fMRI data and compared our results against the conventional scheme (Gaussian smoothing+spatial ICA: s-ICA). The results show significant improvements based on two important features: (1) preservation of shape of the activation region (shape metrics) and (2) receiver operating characteristic curves. It was observed that the proposed framework was able to preserve the actual activation shape in a consistent manner even for very high noise levels in addition to significant reduction in false

  6. A novel Hessian based algorithm for rat kidney glomerulus detection in 3D MRI

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Wu, Teresa; Bennett, Kevin M.

    2015-03-01

    The glomeruli of the kidney perform the key role of blood filtration and the number of glomeruli in a kidney is correlated with susceptibility to chronic kidney disease and chronic cardiovascular disease. This motivates the development of new technology using magnetic resonance imaging (MRI) to measure the number of glomeruli and nephrons in vivo. However, there is currently a lack of computationally efficient techniques to perform fast, reliable and accurate counts of glomeruli in MR images due to the issues inherent in MRI, such as acquisition noise, partial volume effects (the mixture of several tissue signals in a voxel) and bias field (spatial intensity inhomogeneity). Such challenges are particularly severe because the glomeruli are very small, (in our case, a MRI image is ~16 million voxels, each glomerulus is in the size of 8~20 voxels), and the number of glomeruli is very large. To address this, we have developed an efficient Hessian based Difference of Gaussians (HDoG) detector to identify the glomeruli on 3D rat MR images. The image is first smoothed via DoG followed by the Hessian process to pre-segment and delineate the boundary of the glomerulus candidates. This then provides a basis to extract regional features used in an unsupervised clustering algorithm, completing segmentation by removing the false identifications occurred in the pre-segmentation. The experimental results show that Hessian based DoG has the potential to automatically detect glomeruli,from MRI in 3D, enabling new measurements of renal microstructure and pathology in preclinical and clinical studies.

  7. Shape-based multi-region segmentation framework: application to 3D infants MRI data

    NASA Astrophysics Data System (ADS)

    Dahdouh, Sonia; Bloch, Isabelle

    2015-03-01

    This paper presents a novel shape-guided multi-region variational region growing framework for extract- ing simultaneously thoracic and abdominal organs on 3D infants whole body MRI. Due to the inherent low quality of these data, classical segmentation methods tend to fail at the multi-segmentation task. To compensate for the low resolution and the lack of contrast and to enable the simultaneous segmentation of multiple organs, we introduce a segmentation framework on a graph of supervoxels that combines supervoxels intensity distribution weighted by gradient vector ow value and a shape prior per tissue. The intensity-based homogeneity criteria and the shape prior, encoded using Legendre moments, are added as energy terms in the functional to be optimized. The intensity-based energy is computed using both local (voxel value) and global (neighboring regions mean values, adjacent voxels values and distance to the neighboring regions) criteria. Inter-region con ict resolution is handled using a weighted Voronoi decomposition method, the weights being determined using tissues densities. The energy terms of the global energy equation are weighted using an information on growth direction and on gradient vector flow value. This allows us to either guide the segmentation toward the image natural edges if it is consistent with image and shape prior terms, or enforce the shape prior term otherwise. Results on 3D infants MRI data are presented and compared to a set of manual segmentations. Both visual comparison and quantitative measurements show good results.

  8. 3D knee segmentation based on three MRI sequences from different planes.

    PubMed

    Zhou, L; Chav, R; Cresson, T; Chartrand, G; de Guise, J

    2016-08-01

    In clinical practice, knee MRI sequences with 3.5~5 mm slice distance in sagittal, coronal, and axial planes are often requested for the knee examination since its acquisition is faster than high-resolution MRI sequence in a single plane, thereby reducing the probability of motion artifact. In order to take advantage of the three sequences from different planes, a 3D segmentation method based on the combination of three knee models obtained from the three sequences is proposed in this paper. In the method, the sub-segmentation is respectively performed with sagittal, coronal, and axial MRI sequence in the image coordinate system. With each sequence, an initial knee model is hierarchically deformed, and then the three deformed models are mapped to reference coordinate system defined by the DICOM standard and combined to obtain a patient-specific model. The experimental results verified that the three sub-segmentation results can complement each other, and their integration can compensate for the insufficiency of boundary information caused by 3.5~5 mm gap between consecutive slices. Therefore, the obtained patient-specific model is substantially more accurate than each sub-segmentation results.

  9. Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer.

    PubMed

    Haack, Søren; Nielsen, Søren Kynde; Lindegaard, Jacob Christian; Gelineck, John; Tanderup, Kari

    2009-05-01

    To elaborate a method for applicator reconstruction for MRI-based brachytherapy for cervical cancer. Custom-made plastic catheters with a copper sulphate solution were made for insertion in the source channels of MR-CT compatible applicators: plastic and titanium tandem ring applicators, and titanium needles. The applicators were CT and MR scanned in a phantom for accurate 3D assessment of applicator visibility and geometry. A reconstruction method was developed and evaluated in 19 patient MR examinations with ring applicator (plastic: 14, titanium: 5). MR applicator reconstruction uncertainties related to inter-observer variation were evaluated. The catheters were visible in the plastic applicator on T1-weighted images in phantom and in 14/14 clinical applications. On T2-weighted images, the catheters appeared weaker but still visible in phantom and in 13/14 MR clinical applications. In the titanium applicator, the catheters could not be separated from the artifacts from the applicator itself. However, these artifacts could be used to localize both titanium ring applicator (5/5 clinical applications) and needles (6/6 clinical applications). Standard deviations of inter-observer differences were below 2 mm in all directions. 3D applicator reconstruction based on MR imaging could be performed for plastic and titanium applicators. Plastic applicators proved well to be suited for MRI-based reconstruction. For improved practicability of titanium applicator reconstruction, development of MR applicator markers is essential. Reconstruction of titanium applicator and needles at 1.5 T MR requires geometric evaluations in phantoms before using the applicator in patients.

  10. MRI-based aortic blood flow model in 3D ballistocardiography.

    PubMed

    Lejeune, L; Prisk, G K; Nonclercq, A; Migeotte, P-F

    2015-01-01

    Ballistocardiography (BCG) is a non-invasive technique which measures the acceleration of a body induced by cardiovascular activity, namely the force exerted by the beating heart. A one dimensional aortic flow model based on the transmission lines theory is developped and applied to the simulation of three dimensional BCG. A four-element Windkessel model is used to generate the pressure-wave. Using transverse MRI slices of a human subject, a reconstruction of the aorta allows the extraction of parameters used to relate the local change in mass of the 1D flow model to 3D acceleration BCG. Simulated BCG curves are then compared qualitatively with the ensemble average curves of the same subject recorded in sustained microgravity. Confirming previous studies, the main features of the y-axis are well simulated. The simulated z-axis, never attempted before, shows important similarities. The simulated x-axis is less faithful and suggests the presence of reflections.

  11. A high performance 3D cluster-based test of unsmoothed fMRI data.

    PubMed

    Li, Huanjie; Nickerson, Lisa D; Xiong, Jinhu; Zou, Qihong; Fan, Yang; Ma, Yajun; Shi, Tingqi; Ge, Jianqiao; Gao, Jia-Hong

    2014-09-01

    Cluster-size tests (CST) based on random field theory have been widely adopted in fMRI data analysis to detect brain activation. However, most existing approaches can be used appropriately only when the image is highly smoothed in the spatial domain. Unfortunately, spatial smoothing degrades spatial specificity. Recently, a threshold-free cluster enhancement technique was proposed which does not require spatial smoothing, but this method can be used only for group level analysis. Advances in imaging technology now yield high quality high spatial resolution imaging data in single subjects and an inference approach that retains the benefits of greater spatial resolution is called for. In this work, we present a new CST with a correction for voxelation to address this problem. The theoretical formulation of the new approach based on Gaussian random fields is developed to estimate statistical significance using 3D statistical parametric maps without assuming spatial smoothness. Simulated phantom and resting-state fMRI experimental data are then used to compare the voxelation-corrected procedure to the widely used standard random field theory. Unlike standard random field theory approaches, which require heavy spatial smoothing, the new approach has a higher sensitivity for localizing activation regions without the requirement of spatial smoothness. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology

    NASA Astrophysics Data System (ADS)

    van Engelen, Arna; Niessen, Wiro J.; Klein, Stefan; Groen, Harald C.; Verhagen, Hence JM; Wentzel, Jolanda J.; van der Lugt, Aad; de Bruijne, Marleen

    2012-01-01

    We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for fibrous, necrotic and calcified tissue was provided by histology and μCT in 12 carotid plaque specimens. Semi-automatic registration of a 3D stack of histological slices and μCT images to MRI allowed for 3D rotations and in-plane deformations of histology. By basing voxelwise classification on different combinations of features, we evaluated their relative importance. To establish whether training by 3D registration yields different results than training by 2D registration, we determined plaque composition using (1) a 2D slice-based registration approach for three manually selected MRI and histology slices per specimen, and (2) an approach that uses only the three corresponding MRI slices from the 3D-registered volumes. Voxelwise classification accuracy was best when all features were used (73.3 ± 6.3%) and was significantly better than when only original intensities and distance features were used (Friedman, p < 0.05). Although 2D registration or selection of three slices from the 3D set slightly decreased accuracy, these differences were non-significant.

  13. Fractality in the neuron axonal topography of the human brain based on 3-D diffusion MRI

    NASA Astrophysics Data System (ADS)

    Katsaloulis, P.; Ghosh, A.; Philippe, A. C.; Provata, A.; Deriche, R.

    2012-05-01

    In this work the fractal architecture of the neuron axonal topography of the human brain is evaluated, as derived from 3-D diffusion MRI (dMRI) acquisitions. This is a 3D extension of work performed previously in 2D regions of interest (ROIs), where the fractal dimension of the neuron axonal topography was computed from dMRI data. A group study with 18 subjects is here conducted and the fractal dimensions D f of the entire 3-D volume of the brains is estimated via the box counting, the correlation dimension and the fractal mass dimension methods. The neuron axon data is obtained using tractography algorithms on diffusion tensor imaging of the brain. We find that all three calculations of D f give consistent results across subjects, namely, they demonstrate fractal characteristics in the short and medium length scales: different fractal exponents prevail at different length scales, an indication of multifractality. We surmise that this complexity stems as a collective property emerging when many local brain units, performing different functional tasks and having different local topologies, are recorded together.

  14. Motion corrected LV quantification based on 3D modelling for improved functional assessment in cardiac MRI

    NASA Astrophysics Data System (ADS)

    Liew, Y. M.; McLaughlin, R. A.; Chan, B. T.; Aziz, Y. F. Abdul; Chee, K. H.; Ung, N. M.; Tan, L. K.; Lai, K. W.; Ng, S.; Lim, E.

    2015-04-01

    Cine MRI is a clinical reference standard for the quantitative assessment of cardiac function, but reproducibility is confounded by motion artefacts. We explore the feasibility of a motion corrected 3D left ventricle (LV) quantification method, incorporating multislice image registration into the 3D model reconstruction, to improve reproducibility of 3D LV functional quantification. Multi-breath-hold short-axis and radial long-axis images were acquired from 10 patients and 10 healthy subjects. The proposed framework reduced misalignment between slices to subpixel accuracy (2.88 to 1.21 mm), and improved interstudy reproducibility for 5 important clinical functional measures, i.e. end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and 3D-sphericity index, as reflected in a reduction in the sample size required to detect statistically significant cardiac changes: a reduction of 21-66%. Our investigation on the optimum registration parameters, including both cardiac time frames and number of long-axis (LA) slices, suggested that a single time frame is adequate for motion correction whereas integrating more LA slices can improve registration and model reconstruction accuracy for improved functional quantification especially on datasets with severe motion artefacts.

  15. Lossy to lossless object-based coding of 3-D MRI data.

    PubMed

    Menegaz, Gloria; Thiran, Jean-Philippe

    2002-01-01

    We propose a fully three-dimensional (3-D) object-based coding system exploiting the diagnostic relevance of the different regions of the volumetric data for rate allocation. The data are first decorrelated via a 3-D discrete wavelet transform. The implementation via the lifting steps scheme allows to map integer-to-integer values, enabling lossless coding, and facilitates the definition of the object-based inverse transform. The coding process assigns disjoint segments of the bitstream to the different objects, which can be independently accessed and reconstructed at any up-to-lossless quality. Two fully 3-D coding strategies are considered: embedded zerotree coding (EZW-3D) and multidimensional layered zero coding (MLZC), both generalized for region of interest (ROI)-based processing. In order to avoid artifacts along region boundaries, some extra coefficients must be encoded for each object. This gives rise to an overheading of the bitstream with respect to the case where the volume is encoded as a whole. The amount of such extra information depends on both the filter length and the decomposition depth. The system is characterized on a set of head magnetic resonance images. Results show that MLZC and EZW-3D have competitive performances. In particular, the best MLZC mode outperforms the others state-of-the-art techniques on one of the datasets for which results are available in the literature.

  16. Research on 3D modeling for head MRI image based on immune sphere-shaped support vector machine.

    PubMed

    Guo, Lei; Wang, Lei; Wu, Youxi; Yan, Weili; Shen, Xueqin

    2007-01-01

    In head MRI image sequences, the boundary of each encephalic tissue is highly complicated and irregular. It is a real challenge to traditional 3D modeling algorithms. Support Vector Machine (SVM) based on statistical learning theory has solid theoretical foundation. Sphere-Shaped SVM (SSSVM) was originally developed for solving some special classification problems. In this paper, it is extended to image 3D modeling which tries to find the smallest hypersphere enclosing target data in high dimensional space by kernel function. However, selecting parameter is a complicated problem which directly affects modeling accuracy. Immune Algorithm (IA), mainly applied to optimization, is used to search optimal parameter for SSSVM. So, Immune SSSVM (ISSSVM) is proposed to construct the 3D models for encephalic tissues. As our experiment demonstrates, the models are constructed and reach satisfactory modeling accuracies. Theory and experiment indicate ISSSVM exhibits its great potential in image 3D modeling.

  17. Rule-based fuzzy vector median filters for 3D phase contrast MRI segmentation

    NASA Astrophysics Data System (ADS)

    Sundareswaran, Kartik S.; Frakes, David H.; Yoganathan, Ajit P.

    2008-02-01

    Recent technological advances have contributed to the advent of phase contrast magnetic resonance imaging (PCMRI) as standard practice in clinical environments. In particular, decreased scan times have made using the modality more feasible. PCMRI is now a common tool for flow quantification, and for more complex vector field analyses that target the early detection of problematic flow conditions. Segmentation is one component of this type of application that can impact the accuracy of the final product dramatically. Vascular segmentation, in general, is a long-standing problem that has received significant attention. Segmentation in the context of PCMRI data, however, has been explored less and can benefit from object-based image processing techniques that incorporate fluids specific information. Here we present a fuzzy rule-based adaptive vector median filtering (FAVMF) algorithm that in combination with active contour modeling facilitates high-quality PCMRI segmentation while mitigating the effects of noise. The FAVMF technique was tested on 111 synthetically generated PC MRI slices and on 15 patients with congenital heart disease. The results were compared to other multi-dimensional filters namely the adaptive vector median filter, the adaptive vector directional filter, and the scalar low pass filter commonly used in PC MRI applications. FAVMF significantly outperformed the standard filtering methods (p < 0.0001). Two conclusions can be drawn from these results: a) Filtering should be performed after vessel segmentation of PC MRI; b) Vector based filtering methods should be used instead of scalar techniques.

  18. 3D-Dixon MRI based volumetry of peri- and epicardial fat.

    PubMed

    Homsi, Rami; Meier-Schroers, Michael; Gieseke, Jürgen; Dabir, Darius; Luetkens, Julian A; Kuetting, Daniel L; Naehle, Claas P; Marx, Christian; Schild, Hans H; Thomas, Daniel K; Sprinkart, Alois M

    2016-02-01

    There is growing evidence that pericardial and epicardial fat volume (PFV, EFV) are associated with cardiovascular risk. We evaluated a novel method for accurate measurement of PFV and EFV using a 3D-Dixon based cardiac magnetic resonance (CMR) approach. An electrocardiography triggered and respiratory navigator gated 3D-gradient echo pulse sequence was used for cardiac Dixon imaging. Based on this sequence, voxels predominantly containing fat were identified and added up for volumetry. After accuracy assessment in phantoms, consisting of muscle tissue and seven different fat samples (50-200 ml), the sequence was acquired in 34 healthy volunteers (22 male, BMI range 14-42 kg/m(2), age range 21-79 years) at 1.5 T. Analysis was performed independently by two readers who draw two 3D-regions of interest, one for EFV and one for PFV. Additionally, EFV and PFV were compared between overweighted and non-overweighted subjects. The phantom study showed an excellent agreement of measured and true fat volumes (maximum difference = 6 %, linear correlation coefficient R = 1.00). PFV over all volunteers was 158.0 ± 126.4 ml and EFV was 77.0 ± 55.3 ml. PFV and EFV were highly correlated (R = 0.96). Inter-reader agreement was good with a mean difference of 0.2 ± 5.6 and 4.5 ± 4.2 ml for PFV/EFV, (R > 0.99, each). EFV and PFV differed significantly between subjects with BMI > 25 kg/m(2) and BMI < 25 kg/m(2), n = 17 each (PFV 219.0 ± 151.8 vs. 96.9 ± 44.7 ml and EFV 102.3 ± 66.3 vs. 51.7 ± 23.6 ml, p < 0.001, each). The proposed 3D-Dixon based method allows accurate measurement of cardiac fat volumes. It provides a valuable tool for cardiovascular risk stratification by CMR.

  19. Segmentation of Brain MRI Using SOM-FCM-Based Method and 3D Statistical Descriptors

    PubMed Central

    Ortiz, Andrés; Palacio, Antonio A.; Górriz, Juan M.; Ramírez, Javier; Salas-González, Diego

    2013-01-01

    Current medical imaging systems provide excellent spatial resolution, high tissue contrast, and up to 65535 intensity levels. Thus, image processing techniques which aim to exploit the information contained in the images are necessary for using these images in computer-aided diagnosis (CAD) systems. Image segmentation may be defined as the process of parcelling the image to delimit different neuroanatomical tissues present on the brain. In this paper we propose a segmentation technique using 3D statistical features extracted from the volume image. In addition, the presented method is based on unsupervised vector quantization and fuzzy clustering techniques and does not use any a priori information. The resulting fuzzy segmentation method addresses the problem of partial volume effect (PVE) and has been assessed using real brain images from the Internet Brain Image Repository (IBSR). PMID:23762192

  20. Global brain atrophy and corticospinal tract alterations in ALS, as investigated by voxel-based morphometry of 3-D MRI.

    PubMed

    Kassubek, Jan; Unrath, Alexander; Huppertz, Hans-Jürgen; Lulé, Dorothée; Ethofer, Thomas; Sperfeld, Anne-Dorte; Ludolph, Albert C

    2005-12-01

    In ALS, advanced magnetic resonance imaging (MRI) techniques are increasingly used to investigate the underlying pathology. In this study, the technique of voxel-based morphometry (VBM) was applied to 3-D MRI data in ALS patients to localize regional grey and white matter changes. Twenty-two ALS patients (mean age 58+/-9 years) with clinically definite ALS by revised El Escorial criteria were studied. None of the patients had any signs of associated frontotemporal dementia. High-resolution 3-D MRI data sets of the whole brain, collected on a 1.5 T scanner, were analysed by statistical parametric mapping (SPM) and VBM in comparison to an age-matched normal data base consisting of 22 healthy volunteers (mean age 59+/-11 years), for grey matter and white matter segments separately. Global brain atrophy was assessed by calculation of brain parenchymal fractions (BPF). In ALS patients, BPF were significantly reduced compared to controls (p = 0.0003), indicating global brain atrophy. Regional decreases of grey matter density were found in the ALS patients at corrected p<0.01 in the right-hemispheric primary motor cortex (area of the highest Z-score) and in the left medial frontal gyrus. Furthermore, regional white matter alterations were observed along the corticospinal tracts bilaterally and in multiple smaller areas including corpus callosum, cerebellum, frontal and occipital subcortical regions. Besides considerable global atrophy in ALS, the topography of ALS-associated cerebral morphological changes could be mapped using VBM, in particular white matter signal changes along the bilateral corticospinal tracts, but also in extra-motor areas. VBM might be a potential tool to visualize disease progression in future longitudinal studies.

  1. Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction.

    PubMed

    Moghari, Mehdi H; Roujol, Sébastien; Chan, Raymond H; Hong, Susie N; Bello, Natalie; Henningsson, Markus; Ngo, Long H; Goddu, Beth; Goepfert, Lois; Kissinger, Kraig V; Manning, Warren J; Nezafat, Reza

    2013-10-01

    Respiratory motion compensation using diaphragmatic navigator gating with a 5 mm gating window is conventionally used for free-breathing cardiac MRI. Because of the narrow gating window, scan efficiency is low resulting in long scan times, especially for patients with irregular breathing patterns. In this work, a new retrospective motion compensation algorithm is presented to reduce the scan time for free-breathing cardiac MRI that increasing the gating window to 15 mm without compromising image quality. The proposed algorithm iteratively corrects for respiratory-induced cardiac motion by optimizing the sharpness of the heart. To evaluate this technique, two coronary MRI datasets with 1.3 mm(3) resolution were acquired from 11 healthy subjects (seven females, 25 ± 9 years); one using a navigator with a 5 mm gating window acquired in 12.0 ± 2.0 min and one with a 15 mm gating window acquired in 7.1 ± 1.0 min. The images acquired with a 15 mm gating window were corrected using the proposed algorithm and compared to the uncorrected images acquired with the 5 and 15 mm gating windows. The image quality score, sharpness, and length of the three major coronary arteries were equivalent between the corrected images and the images acquired with a 5 mm gating window (P-value > 0.05), while the scan time was reduced by a factor of 1.7. Copyright © 2012 Wiley Periodicals, Inc.

  2. Free-breathing 3D Cardiac MRI Using Iterative Image-Based Respiratory Motion Correction

    PubMed Central

    Moghari, Mehdi H.; Roujol, Sébastien; Chan, Raymond H.; Hong, Susie N.; Bello, Natalie; Henningsson, Markus; Ngo, Long H.; Goddu, Beth; Goepfert, Lois; Kissinger, Kraig V.; Manning, Warren J.; Nezafat, Reza

    2012-01-01

    Respiratory motion compensation using diaphragmatic navigator (NAV) gating with a 5 mm gating window is conventionally used for free-breathing cardiac MRI. Due to the narrow gating window, scan efficiency is low resulting in long scan times, especially for patients with irregular breathing patterns. In this work, a new retrospective motion compensation algorithm is presented to reduce the scan time for free-breathing cardiac MRI that increasing the gating window to 15 mm without compromising image quality. The proposed algorithm iteratively corrects for respiratory-induced cardiac motion by optimizing the sharpness of the heart. To evaluate this technique, two coronary MRI datasets with 1.3 mm3 resolution were acquired from 11 healthy subjects (7 females, 25±9 years); one using a NAV with a 5 mm gating window acquired in 12.0±2.0 minutes and one with a 15 mm gating window acquired in 7.1±1.0 minutes. The images acquired with a 15 mm gating window were corrected using the proposed algorithm and compared to the uncorrected images acquired with the 5 mm and 15 mm gating windows. The image quality score, sharpness, and length of the three major coronary arteries were equivalent between the corrected images and the images acquired with a 5 mm gating window (p-value>0.05), while the scan time was reduced by a factor of 1.7. PMID:23132549

  3. Medical image segmentation using 3D MRI data

    NASA Astrophysics Data System (ADS)

    Voronin, V.; Marchuk, V.; Semenishchev, E.; Cen, Yigang; Agaian, S.

    2017-05-01

    Precise segmentation of three-dimensional (3D) magnetic resonance imaging (MRI) image can be a very useful computer aided diagnosis (CAD) tool in clinical routines. Accurate automatic extraction a 3D component from images obtained by magnetic resonance imaging (MRI) is a challenging segmentation problem due to the small size objects of interest (e.g., blood vessels, bones) in each 2D MRA slice and complex surrounding anatomical structures. Our objective is to develop a specific segmentation scheme for accurately extracting parts of bones from MRI images. In this paper, we use a segmentation algorithm to extract the parts of bones from Magnetic Resonance Imaging (MRI) data sets based on modified active contour method. As a result, the proposed method demonstrates good accuracy in a comparison between the existing segmentation approaches on real MRI data.

  4. 3D MRI-based anisotropic FSI models with cyclic bending for human coronary atherosclerotic plaque mechanical analysis.

    PubMed

    Tang, Dalin; Yang, Chun; Kobayashi, Shunichi; Zheng, Jie; Woodard, Pamela K; Teng, Zhongzhao; Billiar, Kristen; Bach, Richard; Ku, David N

    2009-06-01

    Heart attack and stroke are often caused by atherosclerotic plaque rupture, which happens without warning most of the time. Magnetic resonance imaging (MRI)-based atherosclerotic plaque models with fluid-structure interactions (FSIs) have been introduced to perform flow and stress/strain analysis and identify possible mechanical and morphological indices for accurate plaque vulnerability assessment. For coronary arteries, cyclic bending associated with heart motion and anisotropy of the vessel walls may have significant influence on flow and stress/strain distributions in the plaque. FSI models with cyclic bending and anisotropic vessel properties for coronary plaques are lacking in the current literature. In this paper, cyclic bending and anisotropic vessel properties were added to 3D FSI coronary plaque models so that the models would be more realistic for more accurate computational flow and stress/strain predictions. Six computational models using one ex vivo MRI human coronary plaque specimen data were constructed to assess the effects of cyclic bending, anisotropic vessel properties, pulsating pressure, plaque structure, and axial stretch on plaque stress/strain distributions. Our results indicate that cyclic bending and anisotropic properties may cause 50-800% increase in maximum principal stress (Stress-P1) values at selected locations. The stress increase varies with location and is higher when bending is coupled with axial stretch, nonsmooth plaque structure, and resonant pressure conditions (zero phase angle shift). Effects of cyclic bending on flow behaviors are more modest (9.8% decrease in maximum velocity, 2.5% decrease in flow rate, 15% increase in maximum flow shear stress). Inclusion of cyclic bending, anisotropic vessel material properties, accurate plaque structure, and axial stretch in computational FSI models should lead to a considerable improvement of accuracy of computational stress/strain predictions for coronary plaque vulnerability

  5. MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study

    SciTech Connect

    Dolezel, Martin; Odrazka, Karel; Zizka, Jan; Vanasek, Jaroslav; Kohlova, Tereza; Kroulik, Tomas; Spitzer, Dusan; Ryska, Pavel; Tichy, Michal; Kostal, Milan; Jalcova, Lubica

    2012-09-01

    Purpose: Magnetic resonance imaging (MRI)-assisted radiation treatment planning enables enhanced target contouring. The purpose of this study is to analyze the feasibility and accuracy of computed tomography (CT) and MRI data fusion for MRI-based treatment planning in an institution where an MRI scanner is not available in the radiotherapy department. Methods and Materials: The registration inaccuracy of applicators and soft tissue was assessed in 42 applications with CT/MRI data fusion. The absolute positional difference of the center of the applicators was measured in four different planes from the top of the tandem to the cervix. Any inaccuracy of registration of soft tissue in relation to the position of applicators was determined and dose-volume parameters for MRI preplans and for CT/MRI fusion plans with or without target and organs at risk (OAR) adaptation were evaluated. Results: We performed 6,132 measurements in 42 CT/MRI image fusions. Median absolute difference of the center of tandem on CT and MRI was 1.1 mm. Median distance between the center of the right ovoid on CT and MRI was 1.7 and 1.9 mm in the laterolateral and anteroposterior direction, respectively. Corresponding values for the left ovoid were 1.6 and 1.8 mm. Rotation of applicators was 3.1 Degree-Sign . Median absolute difference in position of applicators in relation to soft tissue was 1.93, 1.50, 1.05, and 0.84 mm in the respective transverse planes, and 1.17, 1.28, 1.27, and 1.17 mm in selected angular directions. The dosimetric parameters for organs at risk on CT/MRI fusion plans without OAR adaptation were significantly impaired whereas the target coverage was not influenced. Planning without target adaptation led to overdosing of the target volume, especially high-risk clinical target volume - D{sub 90} 88.2 vs. 83.1 (p < 0.05). Conclusions: MRI-based preplanning with consecutive CT/MRI data fusion can be safe and feasible, with an acceptable inaccuracy of soft tissue registration.

  6. Posterior Vaginal Prolapse Shape and Position Changes at Maximal Valsalva Seen in 3-D MRI-Based Models

    PubMed Central

    Luo, Jiajia; Larson, Kindra A.; Fenner, Dee E.; Ashton-Miller, James A.; DeLancey, John O.L.

    2013-01-01

    Introduction and Hypothesis Two-dimensional magnetic resonance imaging (MRI) of posterior vaginal prolapse has been studied. However, the three-dimensional (3-D) mechanisms causing such prolapse remain poorly understood. This discovery project was undertaken to identify the different 3-D characteristics of models of rectocele-type posterior vaginal prolapse (PVPR) in women. Methods Ten women with (cases) and 10 without (controls) PVPR were selected from an ongoing case-control study. Supine, multi-planar MR imaging was performed at rest and maximal Valsalva. 3-D reconstructions of the posterior vaginal wall and pelvic bones were created using 3D Slicer v. 3.4.1. In each slice the posterior vaginal wall and perineal skin were outlined to the anterior margin of the external anal sphincter to include the area of the perineal body. Women with predominant enteroceles or anterior vaginal prolapse were excluded. Results The case and control groups had similar demographics. In women with PVPR two characteristics were consistently visible (10 of 10): 1) the posterior vaginal wall displayed a folding phenomenon similar to a person beginning to kneel (“Kneeling” shape); and 2) a downward displacement in the upper 2/3 of the vagina. Also seen in some, but not all of the scans were: 3) forward protrusion of the distal vagina (6 of 10); 4) perineal descent (5 of 10); and 5) distal widening in lower third of the vagina (3 of 10). Conclusions Increased folding (“Kneeling”) of the vagina and an overall downward displacement are consistently present in rectocele. Forward protrusion, perineal descent and distal widening are sometimes seen as well. PMID:22527556

  7. Intersection Based Motion Correction of Multi-Slice MRI for 3D in utero Fetal Brain Image Formation

    PubMed Central

    Kim, Kio; Habas, Piotr A.; Rousseau, Francois; Glenn, Orit A.; Barkovich, Anthony J.; Studholme, Colin

    2012-01-01

    In recent years post-processing of fast multi-slice MR imaging to correct fetal motion has provided the first true 3D MR images of the developing human brain in utero. Early approaches have used reconstruction based algorithms, employing a two step iterative process, where slices from the acquired data are re-aligned to an approximate 3D reconstruction of the fetal brain, which is then refined further using the improved slice alignment. This two step slice-to-volume process, although powerful, is computationally expensive in needing a 3D reconstruction, and is limited in its ability to recover sub-voxel alignment. Here, we describe an alternative approach which we term slice intersection motion correction (SIMC), that seeks to directly co-align multiple slice stacks by considering the matching structure along all intersecting slice pairs in all orthogonally planned slices that are acquired in clinical imaging studies. A collective update scheme for all slices is then derived, to simultaneously drive slices into a consistent match along their lines of intersection. We then describe a 3D reconstruction algorithm that, using the final motion corrected slice locations, suppresses through-plane partial volume effects to provide a single high isotropic resolution 3D image. The method is tested on simulated data with known motions and is applied to retrospectively reconstruct 3D images from a range of clinically acquired imaging studies. The quantitative evaluation of the registration accuracy for the simulated data sets demonstrated a significant improvement over previous approaches. An initial application of the technique to studying clinical pathology is included, where the proposed method recovered up to 15 mm of translation and 30 degrees of rotation for individual slices, and produced full 3D reconstructions containing clinically useful additional information not visible in the original 2D slices. PMID:19744911

  8. Volumetric and surface-based 3D MRI analyses of fetal isolated mild ventriculomegaly: brain morphometry in ventriculomegaly.

    PubMed

    Scott, Julia A; Habas, Piotr A; Rajagopalan, Vidya; Kim, Kio; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2013-05-01

    Diagnosis of fetal isolated mild ventriculomegaly (IMVM) is the most common brain abnormality on prenatal ultrasound. We have set to identify potential alterations in brain development specific to IMVM in tissue volume and cortical and ventricular local surface curvature derived from in utero magnetic resonance imaging (MRI). Multislice 2D T2-weighted MRI were acquired from 32 fetuses (16 IMVM, 16 controls) between 22 and 25.5 gestational weeks. The images were motion-corrected and reconstructed into 3D volumes for volumetric and curvature analyses. The brain images were automatically segmented into cortical plate, cerebral mantle, deep gray nuclei, and ventricles. Volumes were compared between IMVM and control subjects. Surfaces were extracted from the segmentations for local mean surface curvature measurement on the inner cortical plate and the ventricles. Linear models were estimated for age-related and ventricular volume-associated changes in local curvature in both the inner cortical plate and ventricles. While ventricular volume was enlarged in IMVM, all other tissue volumes were not different from the control group. Ventricles increased in curvature with age along the atrium and anterior body. Increasing ventricular volume was associated with reduced curvature over most of the ventricular surface. The cortical plate changed in curvature with age at multiple sites of primary sulcal formation. Reduced cortical folding was detected near the parieto-occipital sulcus in IMVM subjects. While tissue volume appears to be preserved in brains with IMVM, cortical folding may be affected in regions where ventricles are dilated.

  9. Application of contrast-enhanced T1-weighted MRI-based 3D reconstruction of the dural tail sign in meningioma resection.

    PubMed

    You, Binsheng; Cheng, Yanhao; Zhang, Jian; Song, Qimin; Dai, Chao; Heng, Xueyuan; Fei, Chang

    2016-07-01

    OBJECT The goal of this study was to investigate the significance of contrast-enhanced T1-weighted (T1W) MRI-based 3D reconstruction of dural tail sign (DTS) in meningioma resection. METHODS Between May 2013 and August 2014, 18 cases of convexity and parasagittal meningiomas showing DTS on contrast-enhanced T1W MRI were selected. Contrast-enhanced T1W MRI-based 3D reconstruction of DTS was conducted before surgical treatment. The vertical and anteroposterior diameters of DTS on the contrast-enhanced T1W MR images and 3D reconstruction images were measured and compared. Surgical incisions were designed by referring to the 3D reconstruction and MR images, and then the efficiency of the 2 methods was evaluated with assistance of neuronavigation. RESULTS Three-dimensional reconstruction of DTS can reveal its overall picture. In most cases, the DTS around the tumor is uneven, whereas the DTS around the dural vessels presents longer extensions. There was no significant difference (p > 0.05) between the vertical and anteroposterior diameters of DTS measured on the contrast-enhanced T1W MR and 3D reconstruction images. The 3D images of DTS were more intuitive, and the overall picture of DTS could be revealed in 1 image, which made it easier to design the incision than by using the MR images. Meanwhile, assessment showed that the incisions designed using 3D images were more accurate than those designed using MR images (ridit analysis by SAS, F = 7.95; p = 0.008). Pathological examination showed that 34 dural specimens (except 2 specimens from 1 tumor) displayed tumor invasion. The distance of tumor cell invasion was 1.0-21.6 mm (5.4 ± 4.41 mm [mean ± SD]). Tumor cell invasion was not observed at the dural resection margin in all 36 specimens. CONCLUSIONS Contrast-enhanced T1W MRI-based 3D reconstruction can intuitively and accurately reveal the size and shape of DTS, and thus provides guidance for designing meningioma incisions.

  10. Efficient global optimization based 3D carotid AB-LIB MRI segmentation by simultaneously evolving coupled surfaces.

    PubMed

    Ukwatta, Eranga; Yuan, Jing; Rajchl, Martin; Fenster, Aaron

    2012-01-01

    Magnetic resonance (MR) imaging of carotid atherosclerosis biomarkers are increasingly being investigated for the risk assessment of vulnerable plaques. A fast and robust 3D segmentation of the carotid adventitia (AB) and lumen-intima (LIB) boundaries can greatly alleviate the measurement burden of generating quantitative imaging biomarkers in clinical research. In this paper, we propose a novel global optimization-based approach to segment the carotid AB and LIB from 3D T1-weighted black blood MR images, by simultaneously evolving two coupled surfaces with enforcement of anatomical consistency of the AB and LIB. We show that the evolution of two surfaces at each discrete time-frame can be optimized exactly and globally by means of convex relaxation. Our continuous max-flow based algorithm is implemented in GPUs to achieve high computational performance. The experiment results from 16 carotid MR images show that the algorithm obtained high agreement with manual segmentations and achieved high repeatability in segmentation.

  11. A comparison study of atlas-based 3D cardiac MRI segmentation: global versus global and local transformations

    NASA Astrophysics Data System (ADS)

    Daryanani, Aditya; Dangi, Shusil; Ben-Zikri, Yehuda Kfir; Linte, Cristian A.

    2016-03-01

    Magnetic Resonance Imaging (MRI) is a standard-of-care imaging modality for cardiac function assessment and guidance of cardiac interventions thanks to its high image quality and lack of exposure to ionizing radiation. Cardiac health parameters such as left ventricular volume, ejection fraction, myocardial mass, thickness, and strain can be assessed by segmenting the heart from cardiac MRI images. Furthermore, the segmented pre-operative anatomical heart models can be used to precisely identify regions of interest to be treated during minimally invasive therapy. Hence, the use of accurate and computationally efficient segmentation techniques is critical, especially for intra-procedural guidance applications that rely on the peri-operative segmentation of subject-specific datasets without delaying the procedure workflow. Atlas-based segmentation incorporates prior knowledge of the anatomy of interest from expertly annotated image datasets. Typically, the ground truth atlas label is propagated to a test image using a combination of global and local registration. The high computational cost of non-rigid registration motivated us to obtain an initial segmentation using global transformations based on an atlas of the left ventricle from a population of patient MRI images and refine it using well developed technique based on graph cuts. Here we quantitatively compare the segmentations obtained from the global and global plus local atlases and refined using graph cut-based techniques with the expert segmentations according to several similarity metrics, including Dice correlation coefficient, Jaccard coefficient, Hausdorff distance, and Mean absolute distance error.

  12. A negative correlation between human carotid atherosclerotic plaque progression and plaque wall stress: in vivo MRI-based 2D/3D FSI models.

    PubMed

    Tang, Dalin; Yang, Chun; Mondal, Sayan; Liu, Fei; Canton, Gador; Hatsukami, Thomas S; Yuan, Chun

    2008-01-01

    It is well accepted that atherosclerosis initiation and progression correlate positively with low and oscillating flow wall shear stresses (FSS). However, this mechanism cannot explain why advanced plaques continue to grow under elevated FSS conditions. In vivo magnetic resonance imaging (MRI)-based 2D/3D multi-component models with fluid-structure interactions (FSI, 3D only) for human carotid atherosclerotic plaques were introduced to quantify correlations between plaque progression measured by wall thickness increase (WTI) and plaque wall (structure) stress (PWS) conditions. A histologically validated multi-contrast MRI protocol was used to acquire multi-year in vivo MRI images. Our results using 2D models (200-700 data points/patient) indicated that 18 out of 21 patients studied showed significant negative correlation between WTI and PWS at time 2 (T2). The 95% confidence interval for the Pearson correlation coefficient is (-0.443,-0.246), p<0.0001. Our 3D FSI model supported the 2D correlation results and further indicated that combining both plaque structure stress and flow shear stress gave better approximation results (PWS, T2: R(2)=0.279; FSS, T1: R(2)=0.276; combining both: R(2)=0.637). These pilot studies suggest that both lower PWS and lower FSS may contribute to continued plaque progression and should be taken into consideration in future investigations of diseases related to atherosclerosis.

  13. A Negative Correlation between Human Carotid Atherosclerotic Plaque Progression and Plaque Wall Stress: In Vivo MRI-Based 2D/3D FSI Models

    PubMed Central

    Tang, Dalin; Yang, Chun; Mondal, Sayan; Liu, Fei; Canton, Gador; Hatsukami, Thomas S.; Yuan, Chun

    2008-01-01

    It is well accepted that atherosclerosis initiation and progression correlate positively with low and oscillating flow wall shear stresses (FSS). However, this mechanism cannot explain why advanced plaques continue to grow under elevated FSS conditions. In vivo magnetic resonance imaging (MRI)-based 2D/3D multi-component models with fluid-structure interactions (FSI, 3D only) for human carotid atherosclerotic plaques were introduced to quantify correlations between plaque progression measured by wall thickness increase (WTI) and plaque wall (structure) stress (PWS) conditions. A histologically validated multi-contrast MRI protocol was used to acquire multi-year in vivo MRI images. Our results using 2D models (200–700 data points/patient) indicated that 18 out of 21 patients studied showed significant negative correlation between WTI and PWS at time 2 (T2). The 95% confidence interval for the Pearson correlation coefficient is (−0.443, −0.246), p < 0.0001. Our 3D FSI model supported the 2D correlation results and further indicated that combining both plaque structure stress and flow shear stress gave better approximation results (PWS, T2: R2 = 0.279; FSS, T1: R2 = 0.276; Combining both: R2 = 0.637). These pilot studies suggest that both lower PWS and lower FSS may contribute to continued plaque progression and should be taken into consideration in future investigations of diseases related to atherosclerosis. PMID:18191138

  14. Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    PubMed

    Fatnassi, Chemseddine; Boucenna, Rachid; Zaidi, Habib

    2017-07-01

    In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* estimates. If the strong field gradients are measured, their influence can be removed by postprocessing. Conventional corrections usually assume a linear phase evolution with time. For high macroscopic gradient inhomogeneities near the edge of the brain and at the paranasal sinuses, however, this assumption is often broken. Herein, we explored a novel model that considers both linear and stochastic dependences of the phase evolution with echo time in the presence of weak and strong macroscopic field inhomogeneities. We tested the performance of the model at large field gradients using simulation, phantom, and human in vivo studies. The performance of the proposed approach was markedly better than the standard correction method, providing a correction equivalent to that of the conventional approach in regions with high signal to noise ratio (SNR > 10), but appearing more robust in regions with low SNR (SNR < 4). The proposed technique shows promise to improve R2* measurements in regions of large susceptibilities. The clinical and research applications still require further investigation. © 2017 American Association of Physicists in Medicine.

  15. More IMPATIENT: A Gridding-Accelerated Toeplitz-based Strategy for Non-Cartesian High-Resolution 3D MRI on GPUs

    PubMed Central

    Gai, Jiading; Obeid, Nady; Holtrop, Joseph L.; Wu, Xiao-Long; Lam, Fan; Fu, Maojing; Haldar, Justin P.; Hwu, Wen-mei W.; Liang, Zhi-Pei; Sutton, Bradley P.

    2013-01-01

    Several recent methods have been proposed to obtain significant speed-ups in MRI image reconstruction by leveraging the computational power of GPUs. Previously, we implemented a GPU-based image reconstruction technique called the Illinois Massively Parallel Acquisition Toolkit for Image reconstruction with ENhanced Throughput in MRI (IMPATIENT MRI) for reconstructing data collected along arbitrary 3D trajectories. In this paper, we improve IMPATIENT by removing computational bottlenecks by using a gridding approach to accelerate the computation of various data structures needed by the previous routine. Further, we enhance the routine with capabilities for off-resonance correction and multi-sensor parallel imaging reconstruction. Through implementation of optimized gridding into our iterative reconstruction scheme, speed-ups of more than a factor of 200 are provided in the improved GPU implementation compared to the previous accelerated GPU code. PMID:23682203

  16. More IMPATIENT: A Gridding-Accelerated Toeplitz-based Strategy for Non-Cartesian High-Resolution 3D MRI on GPUs.

    PubMed

    Gai, Jiading; Obeid, Nady; Holtrop, Joseph L; Wu, Xiao-Long; Lam, Fan; Fu, Maojing; Haldar, Justin P; Hwu, Wen-Mei W; Liang, Zhi-Pei; Sutton, Bradley P

    2013-05-01

    Several recent methods have been proposed to obtain significant speed-ups in MRI image reconstruction by leveraging the computational power of GPUs. Previously, we implemented a GPU-based image reconstruction technique called the Illinois Massively Parallel Acquisition Toolkit for Image reconstruction with ENhanced Throughput in MRI (IMPATIENT MRI) for reconstructing data collected along arbitrary 3D trajectories. In this paper, we improve IMPATIENT by removing computational bottlenecks by using a gridding approach to accelerate the computation of various data structures needed by the previous routine. Further, we enhance the routine with capabilities for off-resonance correction and multi-sensor parallel imaging reconstruction. Through implementation of optimized gridding into our iterative reconstruction scheme, speed-ups of more than a factor of 200 are provided in the improved GPU implementation compared to the previous accelerated GPU code.

  17. In Vivo/Ex Vivo MRI-Based 3D Non-Newtonian FSI Models for Human Atherosclerotic Plaques Compared with Fluid/Wall-Only Models.

    PubMed

    Yang, Chun; Tang, Dalin; Yuan, Chun; Hatsukami, Thomas S; Zheng, Jie; Woodard, Pamela K

    2007-01-01

    It has been recognized that fluid-structure interactions (FSI) play an important role in cardiovascular disease initiation and development. However, in vivo MRI multi-component FSI models for human carotid atherosclerotic plaques with bifurcation and quantitative comparisons of FSI models with fluid-only or structure-only models are currently lacking in the literature. A 3D non-Newtonian multi-component FSI model based on in vivo/ex vivo MRI images for human atherosclerotic plaques was introduced to investigate flow and plaque stress/strain behaviors which may be related to plaque progression and rupture. Both artery wall and plaque components were assumed to be hyperelastic, isotropic, incompressible and homogeneous. Blood flow was assumed to be laminar, non-Newtonian, viscous and incompressible. In vivo/ex vivo MRI images were acquired using histologically-validated multi-spectral MRI protocols. The 3D FSI models were solved and results were compared with those from a Newtonian FSI model and wall-only/fluid-only models. A 145% difference in maximum principal stresses (Stress-P(1)) between the FSI and wall-only models and 40% difference in flow maximum shear stress (MSS) between the FSI and fluid-only models were found at the throat of the plaque using a severe plaque sample (70% severity by diameter). Flow maximum shear stress (MSS) from the rigid wall model is much higher (20-40% in maximum MSS values, 100-150% in stagnation region) than those from FSI models.

  18. Diagnostic value of MRI-based 3D texture analysis for tissue characterisation and discrimination of low-grade chondrosarcoma from enchondroma: a pilot study.

    PubMed

    Lisson, Catharina S; Lisson, Christoph G; Flosdorf, Kerstin; Mayer-Steinacker, Regine; Schultheiss, Markus; von Baer, Alexandra; Barth, Thomas F E; Beer, Ambros J; Baumhauer, Matthias; Meier, Reinhard; Beer, Meinrad; Schmidt, Stefan A

    2017-09-07

    To explore the diagnostic value of MRI-based 3D texture analysis to identify texture features that can be used for discrimination of low-grade chondrosarcoma from enchondroma. Eleven patients with low-grade chondrosarcoma and 11 patients with enchondroma were retrospectively evaluated. Texture analysis was performed using mint Lesion: Kurtosis, entropy, skewness, mean of positive pixels (MPP) and uniformity of positive pixel distribution (UPP) were obtained in four MRI sequences and correlated with histopathology. The Mann-Whitney U-test and receiver operating characteristic (ROC) analysis were performed to identify most discriminative texture features. Sensitivity, specificity, accuracy and optimal cut-off values were calculated. Significant differences were found in four of 20 texture parameters with regard to the different MRI sequences (p<0.01). The area under the ROC curve values to discriminate chondrosarcoma from enchondroma were 0.876 and 0.826 for kurtosis and skewness in contrast-enhanced T1 (ceT1w), respectively; in non-contrast T1, values were 0.851 and 0.822 for entropy and UPP, respectively. The highest discriminatory power had kurtosis in ceT1w with a cut-off ≥3.15 to identify low-grade chondrosarcoma (82 % sensitivity, 91 % specificity, accuracy 86 %). MRI-based 3D texture analysis might be able to discriminate low-grade chondrosarcoma from enchondroma by a variety of texture parameters. • MRI texture analysis may assist in differentiating low-grade chondrosarcoma from enchondroma. • Kurtosis in the contrast-enhanced T1w has the highest power of discrimination. • Tools provide insight into tumour characterisation as a non-invasive imaging biomarker.

  19. In Vivo/Ex Vivo MRI-Based 3D Non-Newtonian FSI Models for Human Atherosclerotic Plaques Compared with Fluid/Wall-Only Models

    PubMed Central

    Yang, Chun; Tang, Dalin; Yuan, Chun; Hatsukami, Thomas S.; Zheng, Jie; Woodard, Pamela K.

    2009-01-01

    It has been recognized that fluid-structure interactions (FSI) play an important role in cardiovascular disease initiation and development. However, in vivo MRI multi-component FSI models for human carotid atherosclerotic plaques with bifurcation and quantitative comparisons of FSI models with fluid-only or structure-only models are currently lacking in the literature. A 3D non-Newtonian multi-component FSI model based on in vivo/ex vivo MRI images for human atherosclerotic plaques was introduced to investigate flow and plaque stress/strain behaviors which may be related to plaque progression and rupture. Both artery wall and plaque components were assumed to be hyperelastic, isotropic, incompressible and homogeneous. Blood flow was assumed to be laminar, non-Newtonian, viscous and incompressible. In vivo/ex vivo MRI images were acquired using histologically-validated multi-spectral MRI protocols. The 3D FSI models were solved and results were compared with those from a Newtonian FSI model and wall-only/fluid-only models. A 145% difference in maximum principal stresses (Stress-P1) between the FSI and wall-only models and 40% difference in flow maximum shear stress (MSS) between the FSI and fluid-only models were found at the throat of the plaque using a severe plaque sample (70% severity by diameter). Flow maximum shear stress (MSS) from the rigid wall model is much higher (20–40% in maximum MSS values, 100–150% in stagnation region) than those from FSI models. PMID:19784387

  20. A new approach for radiosynoviorthesis: A dose-optimized planning method based on Monte Carlo simulation and synovial measurement using 3D slicer and MRI.

    PubMed

    Torres Berdeguez, Mirta Bárbara; Thomas, Sylvia; Rafful, Patricia; Arruda Sanchez, Tiago; Medeiros Oliveira Ramos, Susie; Souza Albernaz, Marta; Vasconcellos de Sá, Lidia; Lopes de Souza, Sergio Augusto; Mas Milian, Felix; Silva, Ademir Xavier da

    2017-07-01

    Recently, there has been a growing interest in a methodology for dose planning in radiosynoviorthesis to substitute fixed activity. Clinical practice based on fixed activity frequently does not embrace radiopharmaceutical dose optimization in patients. The aim of this paper is to propose and discuss a dose planning methodology considering the radiological findings of interest obtained by three-dimensional magnetic resonance imaging combined with Monte Carlo simulation in radiosynoviorthesis treatment applied to hemophilic arthropathy. The parameters analyzed were: surface area of the synovial membrane (synovial size), synovial thickness and joint effusion obtained by 3D MRI of nine knees from nine patients on a SIEMENS AVANTO 1.5 T scanner using a knee coil. The 3D Slicer software performed both the semiautomatic segmentation and quantitation of these radiological findings. A Lucite phantom 3D MRI validated the quantitation methodology. The study used Monte Carlo N-Particle eXtended code version 2.6 for calculating the S-values required to set up the injected activity to deliver a 100 Gy absorbed dose at a determined synovial thickness. The radionuclides assessed were: 90Y, 32P, 188Re, 186Re, 153Sm, and 177Lu, and the present study shows their effective treatment ranges. The quantitation methodology was successfully tested, with an error below 5% for different materials. S-values calculated could provide data on the activity to be injected into the joint, considering no extra-articular leakage from joint cavity. Calculation of effective treatment range could assist with the therapeutic decision, with an optimized protocol for dose prescription in RSO. Using 3D Slicer software, this study focused on segmentation and quantitation of radiological features such as joint effusion, synovial size, and thickness, all obtained by 3D MRI in patients' knees with hemophilic arthropathy. The combination of synovial size and thickness with the parameters obtained by Monte Carlo

  1. Inverse Planning Approach for 3-D MRI-Based Pulse-Dose Rate Intracavitary Brachytherapy in Cervix Cancer

    SciTech Connect

    Chajon, Enrique; Dumas, Isabelle; Touleimat, Mahmoud B.Sc.; Magne, Nicolas; Coulot, Jeremy; Verstraet, Rodolfe; Lefkopoulos, Dimitri; Haie-Meder, Christine

    2007-11-01

    Purpose: The purpose of this study was to evaluate the inverse planning simulated annealing (IPSA) software for the optimization of dose distribution in patients with cervix carcinoma treated with MRI-based pulsed-dose rate intracavitary brachytherapy. Methods and Materials: Thirty patients treated with a technique using a customized vaginal mold were selected. Dose-volume parameters obtained using the IPSA method were compared with the classic manual optimization method (MOM). Target volumes and organs at risk were delineated according to the Gynecological Brachytherapy Group/European Society for Therapeutic Radiology and Oncology recommendations. Because the pulsed dose rate program was based on clinical experience with low dose rate, dwell time values were required to be as homogeneous as possible. To achieve this goal, different modifications of the IPSA program were applied. Results: The first dose distribution calculated by the IPSA algorithm proposed a heterogeneous distribution of dwell time positions. The mean D90, D100, and V100 calculated with both methods did not differ significantly when the constraints were applied. For the bladder, doses calculated at the ICRU reference point derived from the MOM differed significantly from the doses calculated by the IPSA method (mean, 58.4 vs. 55 Gy respectively; p = 0.0001). For the rectum, the doses calculated at the ICRU reference point were also significantly lower with the IPSA method. Conclusions: The inverse planning method provided fast and automatic solutions for the optimization of dose distribution. However, the straightforward use of IPSA generated significant heterogeneity in dwell time values. Caution is therefore recommended in the use of inverse optimization tools with clinical relevance study of new dosimetric rules.

  2. [Pathophysiological diagnosis of facial paralysis using 3-D MRI].

    PubMed

    Ishihara, T; Hirata, K; Yuki, N; Sato, T

    2001-04-01

    Bilateral facial paralysis(facial diplesia) is often observed in Guillain-Barré syndrome(GBS) and Fisher's syndrome (FS). We tried to observe injured facial nerves using three-dimensional(3-D) MRI in facial diplesia due to GBS and its variants and examined function of blood nerve barrier and clinical use of 3-D MRI for detecting injured facial nerves. In the four patients with GBS and its variants(GBS three cases, FS one case), while routine brain MRI did not show any abnormal findings, contrast-enhanced 3-D MRI revealed Gd-enhancement of the facial nerves. On the other hand, only one case showed visualization using contrast-enhanced 3-D MRI in twelve cases of Bell's palsy. Therefore, it may be presumed that the reason why the significantly higher rate of visualization in facial paralysis in GBS and its variants than in Bell's palsy is attributable to a difference in the mechanism of injury or the extreme seriousness of the disease. In conclusion, the observation of facial nerve using 3-D MRI was very useful to know the condition of the facial diplesia in GBS and its variants.

  3. A New Method to Explore the Spectral Impact of the Piriform Fossae on the Singing Voice: Benchmarking Using MRI-Based 3D-Printed Vocal Tracts

    PubMed Central

    Delvaux, Bertrand; Howard, David

    2014-01-01

    The piriform fossae are the 2 pear-shaped cavities lateral to the laryngeal vestibule at the lower end of the vocal tract. They act acoustically as side-branches to the main tract, resulting in a spectral zero in the output of the human voice. This study investigates their spectral role by comparing numerical and experimental results of MRI-based 3D printed Vocal Tracts, for which a new experimental method (based on room acoustics) is introduced. The findings support results in the literature: the piriform fossae create a spectral trough in the region 4–5 kHz and act as formants repellents. Moreover, this study extends those results by demonstrating numerically and perceptually the impact of having large piriform fossae on the sung output. PMID:25048199

  4. Computer-based vertebral tumor cryoablation planning and procedure simulation involving two cases using MRI-visible 3D printing and advanced visualization

    PubMed Central

    Guenette, Jeffrey P.; Himes, Nathan; Giannopoulos, Andreas A.; Kelil, Tatiana; Mitsouras, Dimitris; Lee, Thomas C.

    2016-01-01

    We report the development and use of MRI-compatible and MRI-visible 3D printed models in conjunction with advanced visualization software models to plan and simulate safe access routes to achieve a theoretical zone of cryoablation for percutaneous image-guided treatment of a C7 pedicle osteoid osteoma and an L1 lamina osteoblastoma. Both models altered procedural planning and patient care. Patient-specific MRI-visible models can be helpful in planning complex percutaneous image-guided cryoablation procedures. PMID:27505064

  5. Computer-Based Vertebral Tumor Cryoablation Planning and Procedure Simulation Involving Two Cases Using MRI-Visible 3D Printing and Advanced Visualization.

    PubMed

    Guenette, Jeffrey P; Himes, Nathan; Giannopoulos, Andreas A; Kelil, Tatiana; Mitsouras, Dimitris; Lee, Thomas C

    2016-11-01

    We report the development and use of MRI-compatible and MRI-visible 3D printed models in conjunction with advanced visualization software models to plan and simulate safe access routes to achieve a theoretic zone of cryoablation for percutaneous image-guided treatment of a C7 pedicle osteoid osteoma and an L1 lamina osteoblastoma. Both models altered procedural planning and patient care. Patient-specific MRI-visible models can be helpful in planning complex percutaneous image-guided cryoablation procedures.

  6. Multimodal-3D imaging based on μMRI and μCT techniques bridges the gap with histology in visualization of the bone regeneration process.

    PubMed

    Sinibaldi, R; Conti, A; Sinjari, B; Spadone, S; Pecci, R; Palombo, M; Komlev, V S; Ortore, M G; Tromba, G; Capuani, S; De Luca, F; Caputi, S; Traini, T; Della Penna, S

    2017-06-07

    Bone repair/regeneration is usually investigated through x-ray computed microtomography (μCT) supported by histology of extracted samples, to analyze biomaterial structure and new bone formation processes. Magnetic Resonance Imaging (μMRI) shows a richer tissue contrast than μCT, despite at lower resolution, and could be combined with μCT in the perspective of conducting non-destructive 3D investigations of bone. A pipeline designed to combine μMRI and μCT images of bone samples is here described and applied on samples of extracted human jawbone core following bone graft. We optimized the co-registration procedure between μCT and μMRI images to avoid bias due to the different resolutions and contrasts. Furthermore, we used an Adaptive Multivariate Clustering, grouping homologous voxels in the co-registered images, to visualize different tissue types within a fused 3D metastructure. The tissue grouping matched the 2D histology applied only on one slice, thus extending the histology labelling in 3D. Specifically, in all samples we could separate and map two types of regenerated bone, calcified tissue, soft tissues and/or fat and marrow space. Remarkably, μMRI and μCT alone were not able to separate the two types of regenerated bone. Finally, we computed volumes of each tissue in the 3D metastructures, which might be exploited by quantitative simulation. The 3D metastructure obtained through our pipeline represents a first step to bridge the gap between the quality of information obtained from 2D optical microscopy and the 3D mapping of the bone tissue heterogeneity, and could allow researchers and clinicians to non-destructively characterize and follow-up bone regeneration. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Velocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics

    PubMed Central

    Sarrami-Foroushani, Ali; Nasr Esfahany, Mohsen; Nasiraei Moghaddam, Abbas; Saligheh Rad, Hamidreza; Firouznia, Kavous; Shakiba, Madjid; Ghanaati, Hossein; Wilkinson, Iain David; Frangi, Alejandro Federico

    2015-01-01

    Background: Understanding hemodynamic environment in vessels is important for realizing the mechanisms leading to vascular pathologies. Objectives: Three-dimensional velocity vector field in carotid bifurcation is visualized using TR 3D phase-contrast magnetic resonance imaging (TR 3D PC MRI) and computational fluid dynamics (CFD). This study aimed to present a qualitative and quantitative comparison of the velocity vector field obtained by each technique. Subjects and Methods: MR imaging was performed on a 30-year old male normal subject. TR 3D PC MRI was performed on a 3 T scanner to measure velocity in carotid bifurcation. 3D anatomical model for CFD was created using images obtained from time-of-flight MR angiography. Velocity vector field in carotid bifurcation was predicted using CFD and PC MRI techniques. A statistical analysis was performed to assess the agreement between the two methods. Results: Although the main flow patterns were the same for the both techniques, CFD showed a greater resolution in mapping the secondary and circulating flows. Overall root mean square (RMS) errors for all the corresponding data points in PC MRI and CFD were 14.27% in peak systole and 12.91% in end diastole relative to maximum velocity measured at each cardiac phase. Bland-Altman plots showed a very good agreement between the two techniques. However, this study was not aimed to validate any of methods, instead, the consistency was assessed to accentuate the similarities and differences between Time-resolved PC MRI and CFD. Conclusion: Both techniques provided quantitatively consistent results of in vivo velocity vector fields in right internal carotid artery (RCA). PC MRI represented a good estimation of main flow patterns inside the vasculature, which seems to be acceptable for clinical use. However, limitations of each technique should be considered while interpreting results. PMID:26793288

  8. SU-E-T-678: Response Calibration Using Electron Depth-Dose Data for MRI-Based 3D Polymer Gel Dosimetry

    SciTech Connect

    Watanabe, Y; Warmington, L; Gopishankar, N

    2015-06-15

    Purpose: To evaluate a calibration method using the depth-dose data of an electron beam for MRI-based polymer gel dosimetry. Methods: MAGAT was manufactured in-house to fill two 400mL-cylindrical phantoms and nine 22mL-glass vials. Phantom-A was irradiated along the cylinder axis with a 9MeV electron beam of 6 cm x 6 cm field size (FS). Phantom-B was irradiated with a 6MV photon beam of 3 cm x 3 cm FS by a 360-degree arc technique. Eight vials were irradiated in a water-bath to various doses with a 20 cm x 20 cm FS 6MV photon beam. All irradiated phantoms and one un-irradiated vial were scanned with a 3T MRI scanner to obtain the spin-spin relaxation rate (R2) distributions. By comparing the measured R2-to-depth data with the known depth-dose data for Phantom-A, R2-to-dose calibration data were obtained (e-beam method). Another calibration data were obtained from the 9 vials data (9-vial method). We tested two regression equations, i.e., third-order polynomial and tangent functions, and two dose normalization methods, i.e., one-point and two-point methods. Then, these two calibration methods were used to obtain the 3D dose distribution of Phantom-B and evaluated by comparing the measured data with the dose distribution from a treatment planning system. The comparison was made with gamma passing rate (2%/2mm criteria). Results: We did not observe a clear advantage of the e-beam method over the 9-vial method for the 3D dose comparison with the test case. Nevertheless, we found that the e-beam method required a smaller dose scaling for the dose comparison. Furthermore, the tangent function showed better data fitting than the polynomial function with smaller uncertainty of the estimated coefficients. Conclusions: Considering the overall superior performance, we recommend the e-beam method with the tangent function as the regression equation and one-point dose normalization for the MRI-based polymer gel dosimetry.

  9. Sodium 3D COncentration MApping (COMA 3D) Using 23Na and Proton MRI

    PubMed Central

    Truong, Milton L.; Harrington, Michael G.; Schepkin, Victor D.; Chekmenev, Eduard Y.

    2014-01-01

    Functional changes of sodium 3D MRI signals were converted into millimolar concentration changes using an open-source fully automated MATLAB toolbox. These concentration changes are visualized via 3D sodium concentration maps, and they are overlaid over conventional 3D proton images to provide high-resolution co-registration for easy correlation of functional changes to anatomical regions. Nearly 5000/hour concentration maps were generated on a personal computer (ca. 2012) using 21.1 T 3D sodium MRI brain images of live rats with spatial resolution of 0.8×0.8×0.8 mm3 and imaging matrices of 60×60×60. The produced concentration maps allowed for non-invasive quantitative measurement of in vivo sodium concentration in the normal rat brain as a functional response to migraine-like conditions. The presented work can also be applied to sodium-associated changes in migraine, cancer, and other metabolic abnormalities that can be sensed by molecular imaging. The MATLAB toolbox allows for automated image analysis of the 3D images acquired on the Bruker platform and can be extended to other imaging platforms. The resulting images are presented in a form of series of 2D slices in all three dimensions in native MATLAB and PDF formats. The following is provided: (a) MATLAB source code for image processing, (b) the detailed processing procedures, (c) description of the code and all sub-routines, (d) example data sets of initial and processed data. The toolbox can be downloaded at: http://www.vuiis.vanderbilt.edu/~truongm/COMA3D/ PMID:25261742

  10. Sodium 3D COncentration MApping (COMA 3D) using 23Na and proton MRI

    NASA Astrophysics Data System (ADS)

    Truong, Milton L.; Harrington, Michael G.; Schepkin, Victor D.; Chekmenev, Eduard Y.

    2014-10-01

    Functional changes of sodium 3D MRI signals were converted into millimolar concentration changes using an open-source fully automated MATLAB toolbox. These concentration changes are visualized via 3D sodium concentration maps, and they are overlaid over conventional 3D proton images to provide high-resolution co-registration for easy correlation of functional changes to anatomical regions. Nearly 5000/h concentration maps were generated on a personal computer (ca. 2012) using 21.1 T 3D sodium MRI brain images of live rats with spatial resolution of 0.8 × 0.8 × 0.8 mm3 and imaging matrices of 60 × 60 × 60. The produced concentration maps allowed for non-invasive quantitative measurement of in vivo sodium concentration in the normal rat brain as a functional response to migraine-like conditions. The presented work can also be applied to sodium-associated changes in migraine, cancer, and other metabolic abnormalities that can be sensed by molecular imaging. The MATLAB toolbox allows for automated image analysis of the 3D images acquired on the Bruker platform and can be extended to other imaging platforms. The resulting images are presented in a form of series of 2D slices in all three dimensions in native MATLAB and PDF formats. The following is provided: (a) MATLAB source code for image processing, (b) the detailed processing procedures, (c) description of the code and all sub-routines, (d) example data sets of initial and processed data. The toolbox can be downloaded at: http://www.vuiis.vanderbilt.edu/~truongm/COMA3D/.

  11. Patient-Specific Carotid Plaque Progression Simulation Using 3D Meshless Generalized Finite Difference Models with Fluid-Structure Interactions Based on Serial In Vivo MRI Data

    PubMed Central

    Yang, Chun; Tang, Dalin; Atluri, Satya

    2011-01-01

    Previously, we introduced a computational procedure based on three-dimensional meshless generalized finite difference (MGFD) method and serial magnetic resonance imaging (MRI) data to quantify patient-specific carotid atherosclerotic plaque growth functions and simulate plaque progression. Structure-only models were used in our previous report. In this paper, fluid-stricture interaction (FSI) was added to improve on prediction accuracy. One participating patient was scanned three times (T1, T2, and T3, at intervals of about 18 months) to obtain plaque progression data. Blood flow was assumed to laminar, Newtonian, viscous and incompressible. The Navier-Stokes equations with arbitrary Lagrangian-Eulerian (ALE) formulation were used as the governing equations. Plaque material was assumed to be uniform, homogeneous, isotropic, linear, and nearly incompressible. The linear elastic model was used. The 3D FSI plaque model was discretized and solved using a meshless generalized finite difference (GFD) method. Growth functions with a) morphology alone; b) morphology and plaque wall stress (PWS); morphology and flow shear stress (FSS), and d) morphology, PWS and FSS were introduced to predict future plaque growth based on previous time point data. Starting from the T2 plaque geometry, plaque progression was simulated by solving the FSI model and adjusting plaque geometry using plaque growth functions iteratively until T3 is reached. Numerically simulated plaque progression agreed very well with the target T3 plaque geometry with errors ranging from 8.62%, 7.22%, 5.77% and 4.39%, with the growth function including morphology, plaque wall stress and flow shear stress terms giving the best predictions. Adding flow shear stress term to the growth function improved the prediction error from 7.22% to 4.39%, a 40% improvement. We believe this is the first time 3D plaque progression FSI simulation based on multi-year patient-tracking data was reported. Serial MRI-based progression

  12. Audio-visual perception of 3D cinematography: an fMRI study using condition-based and computation-based analyses.

    PubMed

    Ogawa, Akitoshi; Bordier, Cecile; Macaluso, Emiliano

    2013-01-01

    The use of naturalistic stimuli to probe sensory functions in the human brain is gaining increasing interest. Previous imaging studies examined brain activity associated with the processing of cinematographic material using both standard "condition-based" designs, as well as "computational" methods based on the extraction of time-varying features of the stimuli (e.g. motion). Here, we exploited both approaches to investigate the neural correlates of complex visual and auditory spatial signals in cinematography. In the first experiment, the participants watched a piece of a commercial movie presented in four blocked conditions: 3D vision with surround sounds (3D-Surround), 3D with monaural sound (3D-Mono), 2D-Surround, and 2D-Mono. In the second experiment, they watched two different segments of the movie both presented continuously in 3D-Surround. The blocked presentation served for standard condition-based analyses, while all datasets were submitted to computation-based analyses. The latter assessed where activity co-varied with visual disparity signals and the complexity of auditory multi-sources signals. The blocked analyses associated 3D viewing with the activation of the dorsal and lateral occipital cortex and superior parietal lobule, while the surround sounds activated the superior and middle temporal gyri (S/MTG). The computation-based analyses revealed the effects of absolute disparity in dorsal occipital and posterior parietal cortices and of disparity gradients in the posterior middle temporal gyrus plus the inferior frontal gyrus. The complexity of the surround sounds was associated with activity in specific sub-regions of S/MTG, even after accounting for changes of sound intensity. These results demonstrate that the processing of naturalistic audio-visual signals entails an extensive set of visual and auditory areas, and that computation-based analyses can track the contribution of complex spatial aspects characterizing such life-like stimuli.

  13. Audio-Visual Perception of 3D Cinematography: An fMRI Study Using Condition-Based and Computation-Based Analyses

    PubMed Central

    Ogawa, Akitoshi; Bordier, Cecile; Macaluso, Emiliano

    2013-01-01

    The use of naturalistic stimuli to probe sensory functions in the human brain is gaining increasing interest. Previous imaging studies examined brain activity associated with the processing of cinematographic material using both standard “condition-based” designs, as well as “computational” methods based on the extraction of time-varying features of the stimuli (e.g. motion). Here, we exploited both approaches to investigate the neural correlates of complex visual and auditory spatial signals in cinematography. In the first experiment, the participants watched a piece of a commercial movie presented in four blocked conditions: 3D vision with surround sounds (3D-Surround), 3D with monaural sound (3D-Mono), 2D-Surround, and 2D-Mono. In the second experiment, they watched two different segments of the movie both presented continuously in 3D-Surround. The blocked presentation served for standard condition-based analyses, while all datasets were submitted to computation-based analyses. The latter assessed where activity co-varied with visual disparity signals and the complexity of auditory multi-sources signals. The blocked analyses associated 3D viewing with the activation of the dorsal and lateral occipital cortex and superior parietal lobule, while the surround sounds activated the superior and middle temporal gyri (S/MTG). The computation-based analyses revealed the effects of absolute disparity in dorsal occipital and posterior parietal cortices and of disparity gradients in the posterior middle temporal gyrus plus the inferior frontal gyrus. The complexity of the surround sounds was associated with activity in specific sub-regions of S/MTG, even after accounting for changes of sound intensity. These results demonstrate that the processing of naturalistic audio-visual signals entails an extensive set of visual and auditory areas, and that computation-based analyses can track the contribution of complex spatial aspects characterizing such life-like stimuli

  14. 3D reconstruction, visualization, and measurement of MRI images

    NASA Astrophysics Data System (ADS)

    Pandya, Abhijit S.; Patel, Pritesh P.; Desai, Mehul B.; Desai, Paramtap

    1999-03-01

    This paper primarily focuses on manipulating 2D medical image data that often come in as Magnetic Resonance and reconstruct them into 3D volumetric images. Clinical diagnosis and therapy planning using 2D medical images can become a torturous problem for a physician. For example, our 2D breast images of a patient mimic a breast carcinoma. In reality, the patient has 'fat necrosis', a benign breast lump. Physicians need powerful, accurate and interactive 3D visualization systems to extract anatomical details and examine the root cause of the problem. Our proposal overcomes the above mentioned limitations through the development of volume rendering algorithms and extensive use of parallel, distributed and neural networks computing strategies. MRI coupled with 3D imaging provides a reliable method for quantifying 'fat necrosis' characteristics and progression. Our 3D interactive application enables a physician to compute spatial measurements and quantitative evaluations and, from a general point of view, use all 3D interactive tools that can help to plan a complex surgical operation. The capability of our medical imaging application can be extended to reconstruct and visualize 3D volumetric brain images. Our application promises to be an important tool in neurological surgery planning, time and cost reduction.

  15. Image segmentation and 3D visualization for MRI mammography

    NASA Astrophysics Data System (ADS)

    Li, Lihua; Chu, Yong; Salem, Angela F.; Clark, Robert A.

    2002-05-01

    MRI mammography has a number of advantages, including the tomographic, and therefore three-dimensional (3-D) nature, of the images. It allows the application of MRI mammography to breasts with dense tissue, post operative scarring, and silicon implants. However, due to the vast quantity of images and subtlety of difference in MR sequence, there is a need for reliable computer diagnosis to reduce the radiologist's workload. The purpose of this work was to develop automatic breast/tissue segmentation and visualization algorithms to aid physicians in detecting and observing abnormalities in breast. Two segmentation algorithms were developed: one for breast segmentation, the other for glandular tissue segmentation. In breast segmentation, the MRI image is first segmented using an adaptive growing clustering method. Two tracing algorithms were then developed to refine the breast air and chest wall boundaries of breast. The glandular tissue segmentation was performed using an adaptive thresholding method, in which the threshold value was spatially adaptive using a sliding window. The 3D visualization of the segmented 2D slices of MRI mammography was implemented under IDL environment. The breast and glandular tissue rendering, slicing and animation were displayed.

  16. Detection of subjects and brain regions related to Alzheimer's disease using 3D MRI scans based on eigenbrain and machine learning.

    PubMed

    Zhang, Yudong; Dong, Zhengchao; Phillips, Preetha; Wang, Shuihua; Ji, Genlin; Yang, Jiquan; Yuan, Ti-Fei

    2015-01-01

    Early diagnosis or detection of Alzheimer's disease (AD) from the normal elder control (NC) is very important. However, the computer-aided diagnosis (CAD) was not widely used, and the classification performance did not reach the standard of practical use. We proposed a novel CAD system for MR brain images based on eigenbrains and machine learning with two goals: accurate detection of both AD subjects and AD-related brain regions. First, we used maximum inter-class variance (ICV) to select key slices from 3D volumetric data. Second, we generated an eigenbrain set for each subject. Third, the most important eigenbrain (MIE) was obtained by Welch's t-test (WTT). Finally, kernel support-vector-machines with different kernels that were trained by particle swarm optimization, were used to make an accurate prediction of AD subjects. Coefficients of MIE with values higher than 0.98 quantile were highlighted to obtain the discriminant regions that distinguish AD from NC. The experiments showed that the proposed method can predict AD subjects with a competitive performance with existing methods, especially the accuracy of the polynomial kernel (92.36 ± 0.94) was better than the linear kernel of 91.47 ± 1.02 and the radial basis function (RBF) kernel of 86.71 ± 1.93. The proposed eigenbrain-based CAD system detected 30 AD-related brain regions (Anterior Cingulate, Caudate Nucleus, Cerebellum, Cingulate Gyrus, Claustrum, Inferior Frontal Gyrus, Inferior Parietal Lobule, Insula, Lateral Ventricle, Lentiform Nucleus, Lingual Gyrus, Medial Frontal Gyrus, Middle Frontal Gyrus, Middle Occipital Gyrus, Middle Temporal Gyrus, Paracentral Lobule, Parahippocampal Gyrus, Postcentral Gyrus, Posterial Cingulate, Precentral Gyrus, Precuneus, Subcallosal Gyrus, Sub-Gyral, Superior Frontal Gyrus, Superior Parietal Lobule, Superior Temporal Gyrus, Supramarginal Gyrus, Thalamus, Transverse Temporal Gyrus, and Uncus). The results were coherent with existing literatures. The eigenbrain method

  17. Crowdsourcing Based 3d Modeling

    NASA Astrophysics Data System (ADS)

    Somogyi, A.; Barsi, A.; Molnar, B.; Lovas, T.

    2016-06-01

    Web-based photo albums that support organizing and viewing the users' images are widely used. These services provide a convenient solution for storing, editing and sharing images. In many cases, the users attach geotags to the images in order to enable using them e.g. in location based applications on social networks. Our paper discusses a procedure that collects open access images from a site frequently visited by tourists. Geotagged pictures showing the image of a sight or tourist attraction are selected and processed in photogrammetric processing software that produces the 3D model of the captured object. For the particular investigation we selected three attractions in Budapest. To assess the geometrical accuracy, we used laser scanner and DSLR as well as smart phone photography to derive reference values to enable verifying the spatial model obtained from the web-album images. The investigation shows how detailed and accurate models could be derived applying photogrammetric processing software, simply by using images of the community, without visiting the site.

  18. Framework for 2D-3D image fusion of infrared thermography with preoperative MRI.

    PubMed

    Hoffmann, Nico; Weidner, Florian; Urban, Peter; Meyer, Tobias; Schnabel, Christian; Radev, Yordan; Schackert, Gabriele; Petersohn, Uwe; Koch, Edmund; Gumhold, Stefan; Steiner, Gerald; Kirsch, Matthias

    2017-01-23

    Multimodal medical image fusion combines information of one or more images in order to improve the diagnostic value. While previous applications mainly focus on merging images from computed tomography, magnetic resonance imaging (MRI), ultrasonic and single-photon emission computed tomography, we propose a novel approach for the registration and fusion of preoperative 3D MRI with intraoperative 2D infrared thermography. Image-guided neurosurgeries are based on neuronavigation systems, which further allow us track the position and orientation of arbitrary cameras. Hereby, we are able to relate the 2D coordinate system of the infrared camera with the 3D MRI coordinate system. The registered image data are now combined by calibration-based image fusion in order to map our intraoperative 2D thermographic images onto the respective brain surface recovered from preoperative MRI. In extensive accuracy measurements, we found that the proposed framework achieves a mean accuracy of 2.46 mm.

  19. Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer

    PubMed Central

    Pötter, Richard; Georg, Petra; Dimopoulos, Johannes C.A.; Grimm, Magdalena; Berger, Daniel; Nesvacil, Nicole; Georg, Dietmar; Schmid, Maximilian P.; Reinthaller, Alexander; Sturdza, Alina; Kirisits, Christian

    2011-01-01

    Background To analyse the overall clinical outcome and benefits by applying protocol based image guided adaptive brachytherapy combined with 3D conformal external beam radiotherapy (EBRT) ± chemotherapy (ChT). Methods Treatment schedule was EBRT with 45–50.4 Gy ± concomitant cisplatin chemotherapy plus 4 × 7 Gy High Dose Rate (HDR) brachytherapy. Patients were treated in the “protocol period” (2001–2008) with the prospective application of the High Risk CTV concept (D90) and dose volume constraints for organs at risk including biological modelling. Dose volume adaptation was performed with the aim of dose escalation in large tumours (prescribed D90 > 85 Gy), often with inserting additional interstitial needles. Dose volume constraints (D2cc) were 70–75 Gy for rectum and sigmoid and 90 Gy for bladder. Late morbidity was prospectively scored, using LENT/SOMA Score. Disease outcome and treatment related late morbidity were evaluated and compared using actuarial analysis. Findings One hundred and fifty-six consecutive patients (median age 58 years) with cervix cancer FIGO stages IB–IVA were treated with definitive radiotherapy in curative intent. Histology was squamous cell cancer in 134 patients (86%), tumour size was >5 cm in 103 patients (66%), lymph node involvement in 75 patients (48%). Median follow-up was 42 months for all patients. Interstitial techniques were used in addition to intracavitary brachytherapy in 69/156 (44%) patients. Total prescribed mean dose (D90) was 93 ± 13 Gy, D2cc 86 ± 17 Gy for bladder, 65 ± 9 Gy for rectum and 64 ± 9 Gy for sigmoid. Complete remission was achieved in 151/156 patients (97%). Overall local control at 3 years was 95%; 98% for tumours 2–5 cm, and 92% for tumours >5 cm (p = 0.04), 100% for IB, 96% for IIB, 86% for IIIB. Cancer specific survival at 3 years was overall 74%, 83% for tumours 2–5 cm, 70% for tumours >5 cm, 83% for IB, 84% for IIB, 52% for IIIB. Overall

  20. Dynamic deformable models for 3D MRI heart segmentation

    NASA Astrophysics Data System (ADS)

    Zhukov, Leonid; Bao, Zhaosheng; Gusikov, Igor; Wood, John; Breen, David E.

    2002-05-01

    Automated or semiautomated segmentation of medical images decreases interstudy variation, observer bias, and postprocessing time as well as providing clincally-relevant quantitative data. In this paper we present a new dynamic deformable modeling approach to 3D segmentation. It utilizes recently developed dynamic remeshing techniques and curvature estimation methods to produce high-quality meshes. The approach has been implemented in an interactive environment that allows a user to specify an initial model and identify key features in the data. These features act as hard constraints that the model must not pass through as it deforms. We have employed the method to perform semi-automatic segmentation of heart structures from cine MRI data.

  1. Laser Based 3D Volumetric Display System

    DTIC Science & Technology

    1993-03-01

    Literature, Costa Mesa, CA July 1983. 3. "A Real Time Autostereoscopic Multiplanar 3D Display System", Rodney Don Williams, Felix Garcia, Jr., Texas...8217 .- NUMBERS LASER BASED 3D VOLUMETRIC DISPLAY SYSTEM PR: CD13 0. AUTHOR(S) PE: N/AWIU: DN303151 P. Soltan, J. Trias, W. Robinson, W. Dahlke 7...laser generated 3D volumetric images on a rotating double helix, (where the 3D displays are computer controlled for group viewing with the naked eye

  2. Brachial plexus 3D reconstruction from MRI with dissection validation: a baseline study for clinical applications.

    PubMed

    Van de Velde, Joris; Bogaert, Stephanie; Vandemaele, Pieter; Huysse, Wouter; Achten, Eric; Leijnse, Joris; De Neve, Wilfried; Van Hoof, Tom

    2016-03-01

    The present study aimed to establish a baseline for detailed 3D brachial plexus reconstruction from magnetic resonance imaging (MRI). Concretely, the goal was to determine the individual brachial plexus anatomy with maximum detail and accuracy achievable, as yet irrespective of whether the methods used could be economically and practically applied in the clinical setting. Six embalmed cadavers were randomly taken for MRI imaging of the brachial plexus. Detailed two-dimensional (2D) segmentation for all brachial plexus parts was done. The 2D brachial plexus segmentations were 3D reconstructed using Mimics(®) software. Then, these 3D reconstructions were anatomically validated by dissection of the cadavers. After finalising the cadaver experiments, brachial plexus MRIs were obtained in three healthy male volunteers and the same reconstruction procedure as in vitro was followed. A procedure was developed for brachial plexus 3D reconstruction based on MRI without the use of any contrast agent. Anatomical validation of six cadaver brachial plexus reconstructions showed high correspondence with the dissected brachial plexuses. Anatomical variations of the main branches were equally present in the 3D reconstructions generated. However, there were also some differences that related to the difference between the surface anatomy of the nerve and the internal nerve structure. In vivo, it was possible to reconstruct the complete brachial plexus in such a manner that normal-appearing BPs were derived in a reproducible way. This study showed that the described procedure results in accurate and reproducible brachial plexus 3D reconstructions.

  3. Bone and joint modeling from 3D knee MRI: feasibility and comparison with radiographs and 2D MRI.

    PubMed

    Wadhwa, Vibhor; Malhotra, Vidur; Xi, Yin; Nordeck, Shaun; Coyner, Katherine; Chhabra, Avneesh

    2016-01-01

    The purpose was to evaluate feasibility of bone and joint segmentations from three-dimensional magnetic resonance imaging (3D MRI). Segmented joint models from 3D MRI data set were obtained for 42 patients. Blinded angular and joint space measurements were performed on 3D MRI model, two-dimensional (2D) MRI, and radiography (XR). Medial joint space was similar on both XR and 3D MRI (P=.3). The XR measurements were statistically different but closer to 3D MRI for lateral patellar tilt angle, patellar tendon length, and lateral knee joint space, whereas 2D MRI measurements were closer to XR in terms of trochlear depth, sulcal angle, and patellar length. 3D bone and joint segmentations are feasible from isotropic MRI data sets. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory.

    PubMed

    Usman, M; Ruijsink, B; Nazir, M S; Cruz, G; Prieto, C

    2017-05-01

    To present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI. 3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4-5min and 4D whole-heart volumes (3D+cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction. For data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P>0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition. The proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5min free breathing acquisition. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. MRI Slice Segmentation and 3D Modelling of Temporomandibular Joint Measured by Microscopic Coil

    NASA Astrophysics Data System (ADS)

    Smirg, O.; Liberda, O.; Smekal, Z.; Sprlakova-Pukova, A.

    2012-01-01

    The paper focuses on the segmentation of magnetic resonance imaging (MRI) slices and 3D modelling of the temporomandibular joint disc in order to help physicians diagnose patients with dysfunction of the temporomandibular joint (TMJ). The TMJ is one of the most complex joints in the human body. The most common joint dysfunction is due to the disc. The disc is a soft tissue, which in principle cannot be diagnosed by the CT method. Therefore, a 3D model is made from the MRI slices, which can image soft tissues. For the segmentation of the disc in individual slices a new method is developed based on spatial distribution and anatomical TMJ structure with automatic thresholding. The thresholding is controlled by a genetic algorithm. The 3D model is realized using the marching cube method.

  6. Registration of 3D ultrasound computer tomography and MRI for evaluation of tissue correspondences

    NASA Astrophysics Data System (ADS)

    Hopp, T.; Dapp, R.; Zapf, M.; Kretzek, E.; Gemmeke, H.; Ruiter, N. V.

    2015-03-01

    3D Ultrasound Computer Tomography (USCT) is a new imaging method for breast cancer diagnosis. In the current state of development it is essential to correlate USCT with a known imaging modality like MRI to evaluate how different tissue types are depicted. Due to different imaging conditions, e.g. with the breast subject to buoyancy in USCT, a direct correlation is demanding. We present a 3D image registration method to reduce positioning differences and allow direct side-by-side comparison of USCT and MRI volumes. It is based on a two-step approach including a buoyancy simulation with a biomechanical model and free form deformations using cubic B-Splines for a surface refinement. Simulation parameters are optimized patient-specifically in a simulated annealing scheme. The method was evaluated with in-vivo datasets resulting in an average registration error below 5mm. Correlating tissue structures can thereby be located in the same or nearby slices in both modalities and three-dimensional non-linear deformations due to the buoyancy are reduced. Image fusion of MRI volumes and USCT sound speed volumes was performed for intuitive display. By applying the registration to data of our first in-vivo study with the KIT 3D USCT, we could correlate several tissue structures in MRI and USCT images and learn how connective tissue, carcinomas and breast implants observed in the MRI are depicted in the USCT imaging modes.

  7. Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs.

    PubMed

    Rosskopf, Andrea B; Buck, Florian M; Pfirrmann, Christian W A; Ramseier, Leonhard E

    2017-04-01

    The aim of our study was to evaluate the reliability and interchangeability of femoral (FT) and tibial torsion (TT) measurements in children using magnetic resonance (MR) imaging compared to measurements on 3D models based on biplanar radiographs (BPR). FT and TT were measured in 60 children (mean age 10.1 years; range 6.2-16.2 years; 28 female) using axial MR images by two readers. MR measurements were compared to measurements based on BPR-3D models by two separate independent readers. Interreader and intermethod agreements were calculated using descriptive statistics, the intraclass correlation coefficient (ICC), and Bland-Altman analysis. FT/TT was -8.4°-54.1°/0°-45.9° on MR images and -13°-63°/4°-52° for measurements on BPR-3D models. The median of difference between the two methods was -0.18° (range -13.6°-19.1°) for FT and -0.20° (range -18.4°-9.5°) for TT, respectively. Interreader agreement (ICC) of FT/TT measurements was 0.98/0.96 on MR images and 0.98/0.94 on BPR 3D models. Intermethod agreement (ICC) for MR measurements was 0.95 [95% confidence interval (CI), 0.93-0.96] for FT and of 0.86 (CI, 0.24-0.95) for TT. Mean interreader differences at MR were 3.1° (0.0°-8.0°) for FT and 3.2° (0.1°-9.5°) for TT. On Bland-Altman plots all measurements were within the 95% limit of agreement (-10.8°; 11.5° for FT; -14.6°; 4.2°) for TT-except for five measurements of FT and six measurements of TT. FT measurements on MR images are comparable to measurements using BPR-3D models. TT measurements differ between the two modalities, but the discrepancy is comparable to measurement variations between CT and BPR.

  8. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions.

    PubMed

    Li, X; Yu, C; Wu, H; Daniel, K; Hu, D; Xia, L; Pan, C; Xu, A; Hu, J; Wang, L; Peng, W; Li, F

    2009-10-01

    To prospectively compare the accuracy of three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) sequences with that of fat-suppressed three-dimensional spoiled gradient-recalled (3D SPGR) in the diagnosis of knee articular cartilage lesions, using arthroscopy as the reference standard. Fifty-eight knees in 54 patients (age range 21-82 years; mean 36 years) were prospectively evaluated by using sagittal 3D FIESTA and sagittal fat-suppressed 3D SPGR sequences. Articular cartilage lesions were graded on MRI and during arthroscopy with a modified Noyes scoring system. Sensitivity, specificity, and accuracy were assessed. Interobserver agreement was determined with kappa statistics. The performance of 3D FIESTA sequences (sensitivity, specificity, and accuracy were 80, 94, and 92%, respectively, for reader 1 and 76, 94, and 90%, respectively, for reader 2) was similar to that of fat-suppressed 3D SPGR sequences (sensitivity, specificity, and accuracy were 82, 92, and 90%, respectively, for reader 1 and 82, 90, and 88%, respectively, for reader 2) in the detection of knee articular cartilage lesions. The interobserver agreement varied from fair to good to excellent (kappa values from 0.43-0.83). 3D FIESTA has good diagnostic performance, comparable with fat-suppressed 3D SPGR in evaluating knee cartilage lesions, and it can be incorporated into routine knee MRI protocols due to the short acquisition time.

  9. 3D printing from MRI Data: Harnessing strengths and minimizing weaknesses.

    PubMed

    Ripley, Beth; Levin, Dmitry; Kelil, Tatiana; Hermsen, Joshua L; Kim, Sooah; Maki, Jeffrey H; Wilson, Gregory J

    2017-03-01

    3D printing facilitates the creation of accurate physical models of patient-specific anatomy from medical imaging datasets. While the majority of models to date are created from computed tomography (CT) data, there is increasing interest in creating models from other datasets, such as ultrasound and magnetic resonance imaging (MRI). MRI, in particular, holds great potential for 3D printing, given its excellent tissue characterization and lack of ionizing radiation. There are, however, challenges to 3D printing from MRI data as well. Here we review the basics of 3D printing, explore the current strengths and weaknesses of printing from MRI data as they pertain to model accuracy, and discuss considerations in the design of MRI sequences for 3D printing. Finally, we explore the future of 3D printing and MRI, including creative applications and new materials.

  10. Measurable realistic image-based 3D mapping

    NASA Astrophysics Data System (ADS)

    Liu, W.; Wang, J.; Wang, J. J.; Ding, W.; Almagbile, A.

    2011-12-01

    realistic image-based (MRI) system can produce. The major contribution here is the implementation of measurable images on 3D maps to obtain various measurements from real scenes.

  11. 3-D brain MRI tissue classification on FPGAs.

    PubMed

    Koo, Jahyun J; Evans, Alan C; Gross, Warren J

    2009-12-01

    Many automatic algorithms have been proposed for analyzing magnetic resonance imaging (MRI) data sets. With the increasingly large data sets being used in brain mapping, there has been a significant rise in the need for accelerating these algorithms. Partial volume estimation (PVE), a brain tissue classification algorithm for MRI, was implemented on a field-programmable gate array (FPGA)-based high performance reconfigurable computer using the Mitrion-C high-level language (HLL). This work develops on prior work in which we conducted initial studies on accelerating the prior information estimation algorithm. In this paper, we extend the work to include probability density estimation and present new results and additional analysis. We used several simulated and real human brain MR images to evaluate the accuracy and performance improvement of the proposed algorithm. The FPGA-based probability density estimation and prior information estimation implementation achieved an average speedup over an Itanium 2 CPU of 2.5 x and 9.4 x , respectively. The overall performance improvement of the FPGA-based PVE algorithm was 5.1 x with four FPGAs.

  12. Computerized Liver Volumetry on MRI by Using 3D Geodesic Active Contour Segmentation

    PubMed Central

    Huynh, Hieu Trung; Karademir, Ibrahim; Oto, Aytekin; Suzuki, Kenji

    2014-01-01

    OBJECTIVE Our purpose was to develop an accurate automated 3D liver segmentation scheme for measuring liver volumes on MRI. SUBJECTS AND METHODS Our scheme for MRI liver volumetry consisted of three main stages. First, the preprocessing stage was applied to T1-weighted MRI of the liver in the portal venous phase to reduce noise and produce the boundary-enhanced image. This boundary-enhanced image was used as a speed function for a 3D fast-marching algorithm to generate an initial surface that roughly approximated the shape of the liver. A 3D geodesic-active-contour segmentation algorithm refined the initial surface to precisely determine the liver boundaries. The liver volumes determined by our scheme were compared with those manually traced by a radiologist, used as the reference standard. RESULTS The two volumetric methods reached excellent agreement (intraclass correlation coefficient, 0.98) without statistical significance (p = 0.42). The average (± SD) accuracy was 99.4% ± 0.14%, and the average Dice overlap coefficient was 93.6% ± 1.7%. The mean processing time for our automated scheme was 1.03 ± 0.13 minutes, whereas that for manual volumetry was 24.0 ± 4.4 minutes (p < 0.001). CONCLUSION The MRI liver volumetry based on our automated scheme agreed excellently with reference-standard volumetry, and it required substantially less completion time. PMID:24370139

  13. VIRTOPSY--scientific documentation, reconstruction and animation in forensic: individual and real 3D data based geo-metric approach including optical body/object surface and radiological CT/MRI scanning.

    PubMed

    Thali, Michael J; Braun, Marcel; Buck, Ursula; Aghayev, Emin; Jackowski, Christian; Vock, Peter; Sonnenschein, Martin; Dirnhofer, Richard

    2005-03-01

    Until today, most of the documentation of forensic relevant medical findings is limited to traditional 2D photography, 2D conventional radiographs, sketches and verbal description. There are still some limitations of the classic documentation in forensic science especially if a 3D documentation is necessary. The goal of this paper is to demonstrate new 3D real data based geo-metric technology approaches. This paper present approaches to a 3D geo-metric documentation of injuries on the body surface and internal injuries in the living and deceased cases. Using modern imaging methods such as photogrammetry, optical surface and radiological CT/MRI scanning in combination it could be demonstrated that a real, full 3D data based individual documentation of the body surface and internal structures is possible in a non-invasive and non-destructive manner. Using the data merging/fusing and animation possibilities, it is possible to answer reconstructive questions of the dynamic development of patterned injuries (morphologic imprints) and to evaluate the possibility, that they are matchable or linkable to suspected injury-causing instruments. For the first time, to our knowledge, the method of optical and radiological 3D scanning was used to document the forensic relevant injuries of human body in combination with vehicle damages. By this complementary documentation approach, individual forensic real data based analysis and animation were possible linking body injuries to vehicle deformations or damages. These data allow conclusions to be drawn for automobile accident research, optimization of vehicle safety (pedestrian and passenger) and for further development of crash dummies. Real 3D data based documentation opens a new horizon for scientific reconstruction and animation by bringing added value and a real quality improvement in forensic science.

  14. 3D-EAUS and MRI in the Activity of Anal Fistulas in Crohn's Disease.

    PubMed

    Alabiso, Maria Eleonora; Iasiello, Francesca; Pellino, Gianluca; Iacomino, Aniello; Roberto, Luca; Pinto, Antonio; Riegler, Gabriele; Selvaggi, Francesco; Reginelli, Alfonso

    2016-01-01

    Aim. This study aspires to assess the role of 3D-Endoanal Ultrasound (3D-EAUS) and Magnetic Resonance Imaging (MRI) in preoperative evaluation of the primary tract and internal opening of perianal fistulas, of secondary extensions and abscess. Methods. During 2014, 51 Crohn's disease patients suspected for perianal fistula were enrolled. All patients underwent physical examination with both the methods and subsequent surgery. Results. In the evaluation of CD perianal fistulas, there are no significant differences between 3D-EAUS and MRI in the identification of abscess and secondary extension. Considering the location, 3D-EAUS was more accurate than MRI in the detection of intersphincteric fistulas (p value = 10(-6)); conversely, MRI was more accurate than 3D-EAUS in the detection of suprasphincteric fistulas (p value = 0.0327) and extrasphincteric fistulas (p  value = 4 ⊕ 10(-6)); there was no significant difference between MRI and 3D-EAUS in the detection of transsphincteric fistulas. Conclusions. Both 3D-EAUS and MRI have a crucial role in the evaluation and detection of CD perianal fistulas. 3D-EAUS was preferable to MRI in the detection of intersphincteric fistulas; conversely, in the evaluation of suprasphincteric and extrasphincteric fistulas the MRI was preferable to 3D-EAUS.

  15. Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography.

    PubMed

    Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A

    2017-07-06

    principal strain analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.

  16. 3D cryo-section/imaging of blood vessel lesions for validation of MRI data

    NASA Astrophysics Data System (ADS)

    Salvado, Olivier; Roy, Debashish; Heinzel, Meredith; McKinley, Eliot; Wilson, David

    2006-03-01

    Vascular disease is a leading cause of death and disability in the western world. Diagnosis and staging of atherosclerosis is a challenge, especially with regards to the identification of plaque vulnerability. We are developing imaging methods based upon MRI and intravascular microcoils. In order to rigorously validate our MRI imaging methods and algorithms, we have developed a new cryo-imaging system that allows one to alternately section and image the block face of tissue. We obtain 3D pathology of vessel segments excised from cadaver and we characterize the tissues of atheroma using episcopic autofluorescence and bright field microscopy images. After embedding the vessel, the block is frozen, and block face microscopic images are taken every 200μm with an image resolution of 30μm×30μm. The series of images is then corrected for uneven illumination, serially registered to one another, and the 3D vessel segment is reconstructed. Some sections are recovered and processed with histological staining for validation. Seven tissue types can be readily identified from the cryo-images: necrotic core, calcification, lipid pool, media, adventitia, fibrosis, thrombus, and normal intima. Since the whole vessel segment is available, we could register 3D data to images from MR, or other modalities, for validation. In addition, visualization tools such as multi-planar reformatting 3D rendering can be used to study 3D plaque morphology, in microscopic detail.

  17. Nonlaser-based 3D surface imaging

    SciTech Connect

    Lu, Shin-yee; Johnson, R.K.; Sherwood, R.J.

    1994-11-15

    3D surface imaging refers to methods that generate a 3D surface representation of objects of a scene under viewing. Laser-based 3D surface imaging systems are commonly used in manufacturing, robotics and biomedical research. Although laser-based systems provide satisfactory solutions for most applications, there are situations where non laser-based approaches are preferred. The issues that make alternative methods sometimes more attractive are: (1) real-time data capturing, (2) eye-safety, (3) portability, and (4) work distance. The focus of this presentation is on generating a 3D surface from multiple 2D projected images using CCD cameras, without a laser light source. Two methods are presented: stereo vision and depth-from-focus. Their applications are described.

  18. Prostate cancer diagnosis using deep learning with 3D multiparametric MRI

    NASA Astrophysics Data System (ADS)

    Liu, Saifeng; Zheng, Huaixiu; Feng, Yesu; Li, Wei

    2017-03-01

    A novel deep learning architecture (XmasNet) based on convolutional neural networks was developed for the classification of prostate cancer lesions, using the 3D multiparametric MRI data provided by the PROSTATEx challenge. End-to-end training was performed for XmasNet, with data augmentation done through 3D rotation and slicing, in order to incorporate the 3D information of the lesion. XmasNet outperformed traditional machine learning models based on engineered features, for both train and test data. For the test data, XmasNet outperformed 69 methods from 33 participating groups and achieved the second highest AUC (0.84) in the PROSTATEx challenge. This study shows the great potential of deep learning for cancer imaging.

  19. Development and Assessment of a New 3D Neuroanatomy Teaching Tool for MRI Training

    ERIC Educational Resources Information Center

    Drapkin, Zachary A.; Lindgren, Kristen A.; Lopez, Michael J.; Stabio, Maureen E.

    2015-01-01

    A computerized three-dimensional (3D) neuroanatomy teaching tool was developed for training medical students to identify subcortical structures on a magnetic resonance imaging (MRI) series of the human brain. This program allows the user to transition rapidly between two-dimensional (2D) MRI slices, 3D object composites, and a combined model in…

  20. Development and Assessment of a New 3D Neuroanatomy Teaching Tool for MRI Training

    ERIC Educational Resources Information Center

    Drapkin, Zachary A.; Lindgren, Kristen A.; Lopez, Michael J.; Stabio, Maureen E.

    2015-01-01

    A computerized three-dimensional (3D) neuroanatomy teaching tool was developed for training medical students to identify subcortical structures on a magnetic resonance imaging (MRI) series of the human brain. This program allows the user to transition rapidly between two-dimensional (2D) MRI slices, 3D object composites, and a combined model in…

  1. Extraction and tracking of MRI tagging sheets using a 3D Gabor filter bank.

    PubMed

    Qian, Zhen; Metaxas, Dimitris N; Axel, Leon

    2006-01-01

    In this paper, we present a novel method for automatically extracting the tagging sheets in tagged cardiac MR images, and tracking their displacement during the heart cycle, using a tunable 3D Gabor filter bank. Tagged MRI is a non-invasive technique for the study of myocardial deformation. We design the 3D Gabor filter bank based on the geometric characteristics of the tagging sheets. The tunable parameters of the Gabor filter bank are used to adapt to the myocardium deformation. The whole 3D image dataset is convolved with each Gabor filter in the filter bank, in the Fourier domain. Then we impose a set of deformable meshes onto the extracted tagging sheets and track them over time. Dynamic estimation of the filter parameters and the mesh internal smoothness are used to help the tracking. Some very encouraging results are shown.

  2. High-Performance 3D Compressive Sensing MRI Reconstruction Using Many-Core Architectures

    PubMed Central

    Kim, Daehyun; Trzasko, Joshua; Smelyanskiy, Mikhail; Haider, Clifton; Dubey, Pradeep; Manduca, Armando

    2011-01-01

    Compressive sensing (CS) describes how sparse signals can be accurately reconstructed from many fewer samples than required by the Nyquist criterion. Since MRI scan duration is proportional to the number of acquired samples, CS has been gaining significant attention in MRI. However, the computationally intensive nature of CS reconstructions has precluded their use in routine clinical practice. In this work, we investigate how different throughput-oriented architectures can benefit one CS algorithm and what levels of acceleration are feasible on different modern platforms. We demonstrate that a CUDA-based code running on an NVIDIA Tesla C2050 GPU can reconstruct a 256 × 160 × 80 volume from an 8-channel acquisition in 19 seconds, which is in itself a significant improvement over the state of the art. We then show that Intel's Knights Ferry can perform the same 3D MRI reconstruction in only 12 seconds, bringing CS methods even closer to clinical viability. PMID:21922017

  3. High-performance 3D compressive sensing MRI reconstruction.

    PubMed

    Kim, Daehyun; Trzasko, Joshua D; Smelyanskiy, Mikhail; Haider, Clifton R; Manduca, Armando; Dubey, Pradeep

    2010-01-01

    Compressive Sensing (CS) is a nascent sampling and reconstruction paradigm that describes how sparse or compressible signals can be accurately approximated using many fewer samples than traditionally believed. In magnetic resonance imaging (MRI), where scan duration is directly proportional to the number of acquired samples, CS has the potential to dramatically decrease scan time. However, the computationally expensive nature of CS reconstructions has so far precluded their use in routine clinical practice - instead, more-easily generated but lower-quality images continue to be used. We investigate the development and optimization of a proven inexact quasi-Newton CS reconstruction algorithm on several modern parallel architectures, including CPUs, GPUs, and Intel's Many Integrated Core (MIC) architecture. Our (optimized) baseline implementation on a quad-core Core i7 is able to reconstruct a 256 × 160×80 volume of the neurovasculature from an 8-channel, 10 × undersampled data set within 56 seconds, which is already a significant improvement over existing implementations. The latest six-core Core i7 reduces the reconstruction time further to 32 seconds. Moreover, we show that the CS algorithm benefits from modern throughput-oriented architectures. Specifically, our CUDA-base implementation on NVIDIA GTX480 reconstructs the same dataset in 16 seconds, while Intel's Knights Ferry (KNF) of the MIC architecture even reduces the time to 12 seconds. Such level of performance allows the neurovascular dataset to be reconstructed within a clinically viable time.

  4. A study on the flip angle for an optimal T1-weighted image based on the 3D-THRIVE MRI technique: Focusing on the detection of a hepatocellular carcinoma (HCC)

    NASA Astrophysics Data System (ADS)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan; Kim, Young-Jae

    2014-04-01

    This study examined the optimal flip angle (FA) for a T1-weighted image in the detection of a hepatocellular carcinoma (HCC). A 3D-T1-weighted high-resolution isotropic volume examination (THRIVE) technique was used to determine the dependence of the signal to noise ratio (SNR) and the contrast-to-noise ratio (CNR) on the change in FA. This study targeted 40 liver cancer patients (25 men and 15 women aged 50 to 70 years with a mean age of 60.32 ± 6.2 years) who visited this hospital to undergo an abdominal MRI examination from January to June 2013. A 3.0 Tesla MRI machine (Philips, Medical System, Achieva) and a MRI receiver coil for data reception with a 16-channel multicoil were used in this study. The THRIVE (repetition time (TR): 8.1 ms, echo time (TE): 3.7 ms, matrix: 172 × 172, slice thickness: 4 mm, gap: 2 mm, field of view (FOV): 350 mm, and band width (BW): 380.1 Hz) technique was applied as a pulse sequence. The time required for the examination was 19 seconds, and the breath-hold technique was used. Axial images were obtained at five FAs: 5, 10, 15, 20 and 25°. The signal intensities of the liver, the lesion and the background noise were measured based on the acquired images before the SNR and the CNR were calculated. To evaluate the image at the FA, we used SPSS for Windows ver. 17.0 to conduct a one-way ANOVA test. A Bonferroni test was conducted as a post-hoc test. The SNRs of the hemorrhagic HCC in the 3D-THRIVE technique were 35.50 ± 4.12, 97.00 ± 10.24, 66.09 ± 7.29, 53.84 ± 5.43, and 42.92 ± 5.11 for FAs of 5, 10, 15, 20, and 25°, respectively (p = 0.0430), whereas the corresponding CNRs were 30.50 ± 3.84, 43.00 ± 5.42, 36.54 ± 4.09, 32.30 ± 2.79, and 31.69 ± 3.21 (p = 0.0003). At a small FA of 10, the SNR and the CNR showed the highest values. As the FA was increased, the SNR and the CNR values showed a decreasing tendency. In conclusion, the optimal T1-weighted image FA should be set to 10° to detect a HCC by using the 3D

  5. Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

    PubMed

    Rispoli, Vinicius C; Nielsen, Jon F; Nayak, Krishna S; Carvalho, Joao L A

    2015-11-26

    Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model assumptions, while velocity fields measured with PC-MRI generally do not satisfy the equations of fluid dynamics, provide limited resolution, and suffer from partial volume effects. The purpose of this study is to develop a proof-of-concept numerical procedure for constructing a simulated flow field that is influenced by both direct PC-MRI measurements and a fluid physics model, thereby taking advantage of both the accuracy of PC-MRI and the high spatial resolution of CFD. The use of the proposed approach in regularizing 3D flow fields is evaluated. The proposed algorithm incorporates both a Newtonian fluid physics model and a linear PC-MRI signal model. The model equations are solved numerically using a modified CFD algorithm. The numerical solution corresponds to the optimal solution of a generalized Tikhonov regularization, which provides a flow field that satisfies the flow physics equations, while being close enough to the measured PC-MRI velocity profile. The feasibility of the proposed approach is demonstrated on data from the carotid bifurcation of one healthy volunteer, and also from a pulsatile carotid flow phantom. The proposed solver produces flow fields that are in better agreement with direct PC-MRI measurements than CFD alone, and converges faster, while closely satisfying the fluid dynamics equations. For the implementation that provided the best results, the signal-to-error ratio (with respect to the PC-MRI measurements) in the phantom experiment was 6.56 dB higher than that of conventional CFD; in the in vivo experiment, it was 2.15 dB higher. The proposed approach

  6. 3D pulmonary perfusion MRI with radial ultra-short echo time and spatial-temporal constrained reconstruction

    PubMed Central

    Bauman, Grzegorz; Johnson, Kevin M.; Bell, Laura C.; Velikina, Julia V.; Samsonov, Alexey A.; Nagle, Scott K.; Fain, Sean B.

    2014-01-01

    Purpose To assess the feasibility of spatial-temporal constrained reconstruction for accelerated regional lung perfusion using highly undersampled dynamic contrast-enhanced (DCE) 3D radial MRI with ultra-short echo time (UTE). Methods A combined strategy was used to accelerate DCE MRI for 3D pulmonary perfusion with whole lung coverage. A highly undersampled 3D radial UTE MRI acquisition was combined with an iterative constrained reconstruction exploiting principal component analysis and wavelet soft-thresholding for dimensionality reduction in space and time. The performance of the method was evaluated using a 3D fractal-based DCE digital lung phantom. Simulated perfusion maps and contrast enhancement curves were compared to ground truth using the structural similarity index (SSIM) to determine robust threshold and regularization levels. Feasibility studies were then performed in a canine and a human subject with 3D radial UTE (TE = 0.08 ms) acquisition to assess feasibility of mapping regional 3D perfusion. Results The method was able to accurately recover perfusion maps in the phantom with a nominal isotropic spatial resolution of 1.5 mm (SSIM of 0.949). The canine and human subject studies demonstrated feasibility for providing artifact-free perfusion maps in a simple 3D breath-held acquisition. Conclusion The proposed method is promising for fast and flexible 3D pulmonary perfusion imaging. PMID:24604452

  7. "Black Bone" MRI: a novel imaging technique for 3D printing.

    PubMed

    Eley, Karen A; Watt-Smith, Stephen R; Golding, Stephen J

    2017-03-01

    Three-dimensionally printed anatomical models are rapidly becoming an integral part of pre-operative planning of complex surgical cases. We have previously reported the "Black Bone" MRI technique as a non-ionizing alternative to CT. Segmentation of bone becomes possible by minimizing soft tissue contrast to enhance the bone-soft tissue boundary. The objectives of this study were to ascertain the potential of utilizing this technique to produce three-dimensional (3D) printed models. "Black Bone" MRI acquired from adult volunteers and infants with craniosynostosis were 3D rendered and 3D printed. A custom phantom provided a surrogate marker of accuracy permitting comparison between direct measurements and 3D printed models created by segmenting both CT and "Black Bone" MRI data sets using two different software packages. "Black Bone" MRI was successfully utilized to produce 3D models of the craniofacial skeleton in both adults and an infant. Measurements of the cube phantom and 3D printed models demonstrated submillimetre discrepancy. In this novel preliminary study exploring the potential of 3D printing from "Black Bone" MRI data, the feasibility of producing anatomical 3D models has been demonstrated, thus offering a potential non-ionizing alterative to CT for the craniofacial skeleton.

  8. Variable flip angle 3D-GRASE for high resolution fMRI at 7 tesla.

    PubMed

    Kemper, Valentin G; De Martino, Federico; Yacoub, Essa; Goebel, Rainer

    2016-09-01

    To evaluate the use of variable flip angle refocusing pulse trains in single-shot three-dimensional gradient and spin-echo (3D-GRASE) to reduce blurring and increase the spatial coverage for high spatial resolution T2 -weighted functional MRI at 7 Tesla. Variable flip angle refocusing schemes in 3D-GRASE were calculated based on extended phase graph theory. The blurring along the slice (partition) direction was evaluated in simulations, as well as phantom and in vivo experiments. Furthermore, temporal stability and functional sensitivity at 0.8 mm isotropic resolution were assessed. Variable flip angle refocusing schemes yielded significantly reduced blurring compared with conventional refocusing schemes, with the full width at half maximum being approximately 30-40% narrower. Simultaneously, spatial coverage could be increased by 80%. The temporal signal-to-noise ratio was slightly reduced, but functional sensitivity was largely maintained due to increased functional contrast in the variable flip angle acquisitions. Signal-to-noise ratio and functional sensitivity were reduced more strongly in areas with insufficient radiofrequency transmission indicating higher sensitivity to experimental imperfections. Variable flip angle refocusing schemes increase usability of 3D-GRASE for high-resolution functional MRI by reducing blurring and allowing increased spatial coverage. Magn Reson Med 76:897-904, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  9. Carotid plaque assessment using fast 3D isotropic resolution black-blood MRI.

    PubMed

    Balu, Niranjan; Yarnykh, Vasily L; Chu, Baocheng; Wang, Jinnan; Hatsukami, Thomas; Yuan, Chun

    2011-03-01

    Black-blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7×0.7×0.7 mm3) three-dimensional black-blood sequence (3D-MERGE) covering the entire cervical carotid arteries within 2 min thus ensuring patient compliance and diagnostic image quality. The sequence is optimized for vessel wall imaging of the carotid bifurcation based on its signal properties. The optimized sequence is validated on patients with significant carotid plaque. Quantitative plaque morphology measurements and signal-to-noise ratio measures show that 3D-MERGE provides good blood suppression and comparable plaque burden measurements to existing MRI protocols. 3D-MERGE is a promising new tool for fast and accurate plaque burden assessment in patients with atherosclerotic plaque. Copyright © 2010 Wiley-Liss, Inc.

  10. (HEL MRI) 3D Meta Optics for High Energy Lasers

    DTIC Science & Technology

    2016-09-13

    DISTRIBUTION A: Distribution approved for public release 2 Archival Publications Generated under this MRI Grant: 1. Morgan , Kaitlyn, Keith Miller...Miller, Kaitlyn Morgan , Matthew Byrd, Sean Osler, Robert Ragusa, Wenzhe Li, Brandon M. Cochenour, and Eric G. Johnson. "Multi- gigabit/s underwater...State Lasers, pp. ATu2A-45. Optical Society of America, 2015. 17. A. Brown, A. Ogloza, L. Taylor, J. Thomas , and J. Talghader, “Continuous wave laser

  11. 3D geometric split-merge segmentation of brain MRI datasets.

    PubMed

    Marras, Ioannis; Nikolaidis, Nikolaos; Pitas, Ioannis

    2014-05-01

    In this paper, a novel method for MRI volume segmentation based on region adaptive splitting and merging is proposed. The method, called Adaptive Geometric Split Merge (AGSM) segmentation, aims at finding complex geometrical shapes that consist of homogeneous geometrical 3D regions. In each volume splitting step, several splitting strategies are examined and the most appropriate is activated. A way to find the maximal homogeneity axis of the volume is also introduced. Along this axis, the volume splitting technique divides the entire volume in a number of large homogeneous 3D regions, while at the same time, it defines more clearly small homogeneous regions within the volume in such a way that they have greater probabilities of survival at the subsequent merging step. Region merging criteria are proposed to this end. The presented segmentation method has been applied to brain MRI medical datasets to provide segmentation results when each voxel is composed of one tissue type (hard segmentation). The volume splitting procedure does not require training data, while it demonstrates improved segmentation performance in noisy brain MRI datasets, when compared to the state of the art methods.

  12. 3D printing of MRI compatible components: why every MRI research group should have a low-budget 3D printer.

    PubMed

    Herrmann, Karl-Heinz; Gärtner, Clemens; Güllmar, Daniel; Krämer, Martin; Reichenbach, Jürgen R

    2014-10-01

    To evaluate low budget 3D printing technology to create MRI compatible components. A 3D printer is used to create customized MRI compatible components, a loop-coil platform and a multipart mouse fixation. The mouse fixation is custom fit for a dedicated coil and facilitates head fixation with bite bar, anesthetic gas supply and biomonitoring sensors. The mouse fixation was tested in a clinical 3T scanner. All parts were successfully printed and proved MR compatible. Both design and printing were accomplished within a few days and the final print results were functional with well defined details and accurate dimensions (Δ<0.4mm). MR images of the mouse head clearly showed reduced motion artifacts, ghosting and signal loss when using the fixation. We have demonstrated that a low budget 3D printer can be used to quickly progress from a concept to a functional device at very low production cost. While 3D printing technology does impose some restrictions on model geometry, additive printing technology can create objects with complex internal structures that can otherwise not be created by using lathe technology. Thus, we consider a 3D printer a valuable asset for MRI research groups. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. MRI 3D CISS– A Novel Imaging Modality in Diagnosing Trigeminal Neuralgia – A Review

    PubMed Central

    Besta, Radhika; Shankar, Y. Uday; Kumar, Ashwini; Prakash, S. Bhanu

    2016-01-01

    Trigeminal Neuralgia (TN) is considered as one of the most painful neurologic disorders affecting oro-facial region. TN is often diagnosed clinically based on the patients complete history of pain (severity, duration, episodes etc), relief of pain on test dose of Carbamazepine, regional block of long acting anaesthetic. However, Magnetic Resonance Imaging (MRI) plays an important and confirmatory role in showing Neuro Vascular Conflict (NVC) which is the commonest causative factor for TN. This article reviews the effectiveness of three-dimensional constructive interference in steady-state (3D-CISS) MRI in diagnosing the exact location, degree of neurovascular conflict responsible for classical as well as atypical TN and possible pre-treatment evaluation and treatment outcome. PMID:27135019

  14. 3-D model-based vehicle tracking.

    PubMed

    Lou, Jianguang; Tan, Tieniu; Hu, Weiming; Yang, Hao; Maybank, Steven J

    2005-10-01

    This paper aims at tracking vehicles from monocular intensity image sequences and presents an efficient and robust approach to three-dimensional (3-D) model-based vehicle tracking. Under the weak perspective assumption and the ground-plane constraint, the movements of model projection in the two-dimensional image plane can be decomposed into two motions: translation and rotation. They are the results of the corresponding movements of 3-D translation on the ground plane (GP) and rotation around the normal of the GP, which can be determined separately. A new metric based on point-to-line segment distance is proposed to evaluate the similarity between an image region and an instantiation of a 3-D vehicle model under a given pose. Based on this, we provide an efficient pose refinement method to refine the vehicle's pose parameters. An improved EKF is also proposed to track and to predict vehicle motion with a precise kinematics model. Experimental results with both indoor and outdoor data show that the algorithm obtains desirable performance even under severe occlusion and clutter.

  15. 3D segmentation of masses in DCE-MRI images using FCM and adaptive MRF

    NASA Astrophysics Data System (ADS)

    Zhang, Chengjie; Li, Lihua

    2014-03-01

    Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is a sensitive imaging modality for the detection of breast cancer. Automated segmentation of breast lesions in DCE-MRI images is challenging due to inherent signal-to-noise ratios and high inter-patient variability. A novel 3D segmentation method based on FCM and MRF is proposed in this study. In this method, a MRI image is segmented by spatial FCM, firstly. And then MRF segmentation is conducted to refine the result. We combined with the 3D information of lesion in the MRF segmentation process by using segmentation result of contiguous slices to constraint the slice segmentation. At the same time, a membership matrix of FCM segmentation result is used for adaptive adjustment of Markov parameters in MRF segmentation process. The proposed method was applied for lesion segmentation on 145 breast DCE-MRI examinations (86 malignant and 59 benign cases). An evaluation of segmentation was taken using the traditional overlap rate method between the segmented region and hand-drawing ground truth. The average overlap rates for benign and malignant lesions are 0.764 and 0.755 respectively. Then we extracted five features based on the segmentation region, and used an artificial neural network (ANN) to classify between malignant and benign cases. The ANN had a classification performance measured by the area under the ROC curve of AUC=0.73. The positive and negative predictive values were 0.86 and 0.58, respectively. The results demonstrate the proposed method not only achieves a better segmentation performance in accuracy also has a reasonable classification performance.

  16. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    PubMed

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  17. Custom Fit 3D-Printed Brain Holders for Comparison of Histology with MRI in Marmosets

    PubMed Central

    Guy, Joseph R.; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C.; Reich, Daniel S.

    2015-01-01

    Background MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. New Method 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. Results The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Comparison with Existing Methods Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. Conclusions The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. PMID:26365332

  18. Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation.

    PubMed

    Romero, X C; Molina, F S; Pastor, E; Amaya, F

    2011-01-01

    Hemimegalencephaly (HMC) is a disorder associated with enlarged and dysplastic hamartomatous overgrowth of all or part of the one cerebral hemisphere that can be isolated or associated with other syndromes. In the normal development of the brain it is important to bear in mind that there are two main processes: firstly the development of the hemispheres and the corpus callosum, and secondly the cortical formation with proliferation, migration and organization of the cortex, which occurs mostly between 12 and 20 weeks of gestation. We present a 22-week-old fetus with macrocephaly depending on HMC and emphasize the possibility of an early ultrasound diagnosis, the correlation in the diagnosis between 2D and 3D ultrasound, and the use of magnetic resonance imaging as an imaging method for a more precise diagnosis of neuronal migration anomalies. The diagnosis of HMC is possible at the time of the anomaly scan. The use and correlation with other diagnostic tools provide essential information for parent counseling in these complex cases. Copyright © 2010 S. Karger AG, Basel.

  19. MRI visible Fe3O4 polypropylene mesh: 3D reconstruction of spatial relation to bony pelvis and neurovascular structures.

    PubMed

    Chen, Luyun; Lenz, Florian; Alt, Céline D; Sohn, Christof; De Lancey, John O; Brocker, Kerstin A

    2017-08-01

    To demonstrate mesh magnetic resonance imaging (MRI) visibility in living women, the feasibility of reconstructing the full mesh course in 3D, and to document its spatial relationship to pelvic anatomical structures. This is a proof of concept study of three patients from a prospective multi-center trial evaluating women with anterior vaginal mesh repair using a MRI-visible Fe3O4 polypropylene implant for pelvic floor reconstruction. High-resolution sagittal T2-weighted (T2w) sequences, transverse T1-weighted (T1w) FLASH 2D, and transverse T1w FLASH 3D sequences were performed to evaluate Fe3O4 polypropylene mesh MRI visibility and overall post-surgical pelvic anatomy 3 months after reconstructive surgery. Full mesh course in addition to important pelvic structures were reconstructed using the 3D Slicer® software program based on T1w and T2w MRI. Three women with POP-Q grade III cystoceles were successfully treated with a partially absorbable MRI-visible anterior vaginal mesh with six fixation arms and showed no recurrent cystocele at the 3-month follow-up examination. The course of mesh in the pelvis was visible on MRI in all three women. The mesh body and arms could be reconstructed allowing visualization of the full course of the mesh in relationship to important pelvic structures such as the obturator or pudendal vessel nerve bundles in 3D. The use of MRI-visible Fe3O4 polypropylene meshes in combination with post-surgical 3D reconstruction of the mesh and adjacent structures is feasible suggesting that it might be a useful tool for evaluating mesh complications more precisely and a valuable interactive feedback tool for surgeons and mesh design engineers.

  20. Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data

    NASA Astrophysics Data System (ADS)

    van der Bom, M. J.; Pluim, J. P. W.; Gounis, M. J.; van de Kraats, E. B.; Sprinkhuizen, S. M.; Timmer, J.; Homan, R.; Bartels, L. W.

    2011-02-01

    Spatial and soft tissue information provided by magnetic resonance imaging can be very valuable during image-guided procedures, where usually only real-time two-dimensional (2D) x-ray images are available. Registration of 2D x-ray images to three-dimensional (3D) magnetic resonance imaging (MRI) data, acquired prior to the procedure, can provide optimal information to guide the procedure. However, registering x-ray images to MRI data is not a trivial task because of their fundamental difference in tissue contrast. This paper presents a technique that generates pseudo-computed tomography (CT) data from multi-spectral MRI acquisitions which is sufficiently similar to real CT data to enable registration of x-ray to MRI with comparable accuracy as registration of x-ray to CT. The method is based on a k-nearest-neighbors (kNN)-regression strategy which labels voxels of MRI data with CT Hounsfield Units. The regression method uses multi-spectral MRI intensities and intensity gradients as features to discriminate between various tissue types. The efficacy of using pseudo-CT data for registration of x-ray to MRI was tested on ex vivo animal data. 2D-3D registration experiments using CT and pseudo-CT data of multiple subjects were performed with a commonly used 2D-3D registration algorithm. On average, the median target registration error for registration of two x-ray images to MRI data was approximately 1 mm larger than for x-ray to CT registration. The authors have shown that pseudo-CT data generated from multi-spectral MRI facilitate registration of MRI to x-ray images. From the experiments it could be concluded that the accuracy achieved was comparable to that of registering x-ray images to CT data.

  1. Semi-automatic segmentation for 3D motion analysis of the tongue with dynamic MRI.

    PubMed

    Lee, Junghoon; Woo, Jonghye; Xing, Fangxu; Murano, Emi Z; Stone, Maureen; Prince, Jerry L

    2014-12-01

    Dynamic MRI has been widely used to track the motion of the tongue and measure its internal deformation during speech and swallowing. Accurate segmentation of the tongue is a prerequisite step to define the target boundary and constrain the tracking to tissue points within the tongue. Segmentation of 2D slices or 3D volumes is challenging because of the large number of slices and time frames involved in the segmentation, as well as the incorporation of numerous local deformations that occur throughout the tongue during motion. In this paper, we propose a semi-automatic approach to segment 3D dynamic MRI of the tongue. The algorithm steps include seeding a few slices at one time frame, propagating seeds to the same slices at different time frames using deformable registration, and random walker segmentation based on these seed positions. This method was validated on the tongue of five normal subjects carrying out the same speech task with multi-slice 2D dynamic cine-MR images obtained at three orthogonal orientations and 26 time frames. The resulting semi-automatic segmentations of a total of 130 volumes showed an average dice similarity coefficient (DSC) score of 0.92 with less segmented volume variability between time frames than in manual segmentations.

  2. Semi-automatic segmentation for 3D motion analysis of the tongue with dynamic MRI

    PubMed Central

    Lee, Junghoon; Woo, Jonghye; Xing, Fangxu; Murano, Emi Z.; Stone, Maureen; Prince, Jerry L.

    2014-01-01

    Dynamic MRI has been widely used to track the motion of the tongue and measure its internal deformation during speech and swallowing. Accurate segmentation of the tongue is a prerequisite step to define the target boundary and constrain the tracking to tissue points within the tongue. Segmentation of 2D slices or 3D volumes is challenging because of the large number of slices and time frames involved in the segmentation, as well as the incorporation of numerous local deformations that occur throughout the tongue during motion. In this paper, we propose a semi-automatic approach to segment 3D dynamic MRI of the tongue. The algorithm steps include seeding a few slices at one time frame, propagating seeds to the same slices at different time frames using deformable registration, and random walker segmentation based on these seed positions. This method was validated on the tongue of five normal subjects carrying out the same speech task with multi-slice 2D dynamic cine-MR images obtained at three orthogonal orientations and 26 time frames. The resulting semi-automatic segmentations of a total of 130 volumes showed an average dice similarity coefficient (DSC) score of 0.92 with less segmented volume variability between time frames than in manual segmentations. PMID:25155697

  3. Correlation of preoperative MRI and intraoperative 3D ultrasound to measure brain tissue shift

    NASA Astrophysics Data System (ADS)

    Gobbi, David G.; Lee, Belinda K. H.; Peters, Terence M.

    2001-05-01

    B-Mode ultrasound is often used during neurosurgery to provide intra-operative images of the brain though a craniotomy, but the use of 3D ultrasound during surgery is still in its infancy. We have developed a system that provides real-time freehand 3D ultrasound reconstruction at a reduced resolution. The reconstruction proceeds incrementally and the 3D image is overlayed, via a computer, on a pre-operative 3D MRI scan. This provides the operator with the necessary feedback to maintain a constant freehand sweep-rate, and also ensures that the sweep covers the desired anatomical volume. All of the ultrasound video frames are buffered, and a full-resolution, compounded reconstruction proceeds once the manual sweep is complete. We have also developed tools for manual tagging of homologous landmarks in the 3D MRI and 3D ultrasound volumes that use a piecewise cubic approximation of thin-plate spline interpolation to achieve interactive nonlinear registration and warping of the MRI volume to the ultrasound volume: Each time a homologous point-pair is identified by the use, the image of the warped MRI is updated on the computer screen after less than 0.5 s.

  4. TU-F-BRF-06: 3D Pancreas MRI Segmentation Using Dictionary Learning and Manifold Clustering

    SciTech Connect

    Gou, S; Rapacchi, S; Hu, P; Sheng, K

    2014-06-15

    Purpose: The recent advent of MRI guided radiotherapy machines has lent an exciting platform for soft tissue target localization during treatment. However, tools to efficiently utilize MRI images for such purpose have not been developed. Specifically, to efficiently quantify the organ motion, we develop an automated segmentation method using dictionary learning and manifold clustering (DLMC). Methods: Fast 3D HASTE and VIBE MR images of 2 healthy volunteers and 3 patients were acquired. A bounding box was defined to include pancreas and surrounding normal organs including the liver, duodenum and stomach. The first slice of the MRI was used for dictionary learning based on mean-shift clustering and K-SVD sparse representation. Subsequent images were iteratively reconstructed until the error is less than a preset threshold. The preliminarily segmentation was subject to the constraints of manifold clustering. The segmentation results were compared with the mean shift merging (MSM), level set (LS) and manual segmentation methods. Results: DLMC resulted in consistently higher accuracy and robustness than comparing methods. Using manual contours as the ground truth, the mean Dices indices for all subjects are 0.54, 0.56 and 0.67 for MSM, LS and DLMC, respectively based on the HASTE image. The mean Dices indices are 0.70, 0.77 and 0.79 for the three methods based on VIBE images. DLMC is clearly more robust on the patients with the diseased pancreas while LS and MSM tend to over-segment the pancreas. DLMC also achieved higher sensitivity (0.80) and specificity (0.99) combining both imaging techniques. LS achieved equivalent sensitivity on VIBE images but was more computationally inefficient. Conclusion: We showed that pancreas and surrounding normal organs can be reliably segmented based on fast MRI using DLMC. This method will facilitate both planning volume definition and imaging guidance during treatment.

  5. Real-time 3D MRI of contrast agents in whole living mice.

    PubMed

    Bled, Emilie; Hassen, Wadie Ben; Pourtau, Line; Mellet, Philippe; Lanz, Titus; Schüler, Dorothee; Voisin, Pierre; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain

    2011-01-01

    A specific mouse whole body coil and a dedicated gradient system at 4.7 T were coupled with an ultra-fast 3D gradient echo MRI and keyhole reconstruction technique to obtain 3D whole-body dynamic T(1)-weighted or T(2)*-weighted imaging. The technique was used to visualize the real-time distribution of non-targeting T(1) and T(2)* contrast agent (CA) in a glioma-bearing mouse model. T(1) dynamic contrast-enhancement imaging was performed with a fast imaging with steady-state precession sequence [echo time/repetition time (TE/TR), 1.32/3.7 ms] before and after CA injection (Gd-DOTA and BSA-Gd-DOTA) for 21 min. The temporal resolution was 1 image/6.5 s. T(2)* imaging (TE/TR, 4/8 ms) was performed before and after iron-based (small and ultra-small particles of iron oxide) CA injection for 45 min. The temporal resolution was 1 image/14 s. Signal-to-noise ratio curves were determined in various mouse organs. The whole-body coil and gradient systems made it possible to acquire data with sufficient and homogeneous signal-to-noise ratio on the whole animal. The spatial resolution allowed adequate depiction of the major organs, blood vessels and brain glioma. The distribution and the time-course of T(1) and T(2)* contrasts upon contrast agent injection were also assessed. 3D whole-body mouse MRI is feasible at high spatial resolution in movie mode and can be applied successfully to visualize real-time contrast agent distribution. This method should be effective in future preclinical molecular imaging studies. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Development and assessment of a new 3D neuroanatomy teaching tool for MRI training.

    PubMed

    Drapkin, Zachary A; Lindgren, Kristen A; Lopez, Michael J; Stabio, Maureen E

    2015-01-01

    A computerized three-dimensional (3D) neuroanatomy teaching tool was developed for training medical students to identify subcortical structures on a magnetic resonance imaging (MRI) series of the human brain. This program allows the user to transition rapidly between two-dimensional (2D) MRI slices, 3D object composites, and a combined model in which 3D objects are overlaid onto the 2D MRI slices, all while rotating the brain in any direction and advancing through coronal, sagittal, or axial planes. The efficacy of this tool was assessed by comparing scores from an MRI identification quiz and survey in two groups of first-year medical students. The first group was taught using this new 3D teaching tool, and the second group was taught the same content for the same amount of time but with traditional methods, including 2D images of brain MRI slices and 3D models from widely used textbooks and online sources. Students from the experimental group performed marginally better than the control group on overall test score (P = 0.07) and significantly better on test scores extracted from questions involving C-shaped internal brain structures (P < 0.01). Experimental participants also expressed higher confidence in their abilities to visualize the 3D structure of the brain (P = 0.02) after using this tool. Furthermore, when surveyed, 100% of the students in the experimental group recommended this tool for future students. These results suggest that this neuroanatomy teaching tool is an effective way to train medical students to read an MRI of the brain and is particularly effective for teaching C-shaped internal brain structures.

  7. Scalable 3D GIS environment managed by 3D-XML-based modeling

    NASA Astrophysics Data System (ADS)

    Shi, Beiqi; Rui, Jianxun; Chen, Neng

    2008-10-01

    Nowadays, the namely 3D GIS technologies become a key factor in establishing and maintaining large-scale 3D geoinformation services. However, with the rapidly increasing size and complexity of the 3D models being acquired, a pressing needed for suitable data management solutions has become apparent. This paper outlines that storage and exchange of geospatial data between databases and different front ends like 3D models, GIS or internet browsers require a standardized format which is capable to represent instances of 3D GIS models, to minimize loss of information during data transfer and to reduce interface development efforts. After a review of previous methods for spatial 3D data management, a universal lightweight XML-based format for quick and easy sharing of 3D GIS data is presented. 3D data management based on XML is a solution meeting the requirements as stated, which can provide an efficient means for opening a new standard way to create an arbitrary data structure and share it over the Internet. To manage reality-based 3D models, this paper uses 3DXML produced by Dassault Systemes. 3DXML uses opening XML schemas to communicate product geometry, structure and graphical display properties. It can be read, written and enriched by standard tools; and allows users to add extensions based on their own specific requirements. The paper concludes with the presentation of projects from application areas which will benefit from the functionality presented above.

  8. Spatio-temporal registration in multiplane MRI acquisitions for 3D colon motiliy analysis

    NASA Astrophysics Data System (ADS)

    Kutter, Oliver; Kirchhoff, Sonja; Berkovich, Marina; Reiser, Maximilian; Navab, Nassir

    2008-03-01

    In this paper we present a novel method for analyzing and visualizing dynamic peristaltic motion of the colon in 3D from two series of differently oriented 2D MRI images. To this end, we have defined an MRI examination protocol, and introduced methods for spatio-temporal alignment of the two MRI image series into a common reference. This represents the main contribution of this paper, which enables the 3D analysis of peristaltic motion. The objective is to provide a detailed insight into this complex motion, aiding in the diagnosis and characterization of colon motion disorders. We have applied the proposed spatio-temporal method on Cine MRI data sets of healthy volunteers. The results have been inspected and validated by an expert radiologist. Segmentation and cylindrical approximation of the colon results in a 4D visualization of the peristaltic motion.

  9. Compressed sensing MRI reconstruction from 3D multichannel data using GPUs.

    PubMed

    Chang, Ching-Hua; Yu, Xiangdong; Ji, Jim X

    2017-02-15

    To accelerate iterative reconstructions of compressed sensing (CS) MRI from 3D multichannel data using graphics processing units (GPUs). The sparsity of MRI signals and parallel array receivers can reduce the data acquisition requirements. However, iterative CS reconstructions from data acquired using an array system may take a significantly long time, especially for a large number of parallel channels. This paper presents an efficient method for CS-MRI reconstruction from 3D multichannel data using GPUs. In this method, CS reconstructions were simultaneously processed in a channel-by-channel fashion on the GPU, in which the computations of multiple-channel 3D-CS reconstructions are highly parallelized. The final image was then produced by a sum-of-squares method on the central processing unit. Implementation details including algorithm, data/memory management, and parallelization schemes are reported in the paper. Both simulated data and in vivo MRI array data were tested. The results showed that the proposed method can significantly improve the image reconstruction efficiency, typically shortening the runtime by a factor of 30. Using low-cost GPUs and an efficient algorithm allowed the 3D multislice compressive-sensing reconstruction to be performed in less than 1 s. The rapid reconstructions are expected to help bring high-dimensional, multichannel parallel CS MRI closer to clinical applications. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Comparison of 3D Orientation Distribution Functions Measured with Confocal Microscopy and Diffusion MRI

    PubMed Central

    Schilling, Kurt; Janve, Vaibhav; Gao, Yurui; Stepniewska, Iwona; Landman, Bennett A; Anderson, Adam W

    2016-01-01

    The ability of diffusion MRI (dMRI) fiber tractography to non-invasively map three-dimensional (3D) anatomical networks in the human brain has made it a valuable tool in both clinical and research settings. However, there are many assumptions inherent to any tractography algorithm that can limit the accuracy of the reconstructed fiber tracts. Among them is the assumption that the diffusion-weighted images accurately reflect the underlying fiber orientation distribution (FOD) in the MRI voxel. Consequently, validating dMRI’s ability to assess the underlying fiber orientation in each voxel is critical for its use as a biomedical tool. Here, using post-mortem histology and confocal microscopy, we present a method to perform histological validation of orientation functions in 3D, which has previously been limited to two-dimensional analysis of tissue sections. We demonstrate the ability to extract the 3D FOD from confocal z-stacks, and quantify the agreement between the MRI estimates of orientation information obtained using constrained spherical deconvolution (CSD) and the true geometry of the fibers. We find an orientation error of approximately 6° in voxels containing nearly parallel fibers, and 10-11° in crossing fiber regions, and note that CSD was unable to resolve fibers crossing at angles below 60° in our dataset. This is the first time the 3D white matter orientation distribution is calculated from histology and compared to dMRI. Thus, this technique serves as a gold standard for dMRI validation studies - providing the ability to determine the extent to which the dMRI signal is consistent with the histological FOD, and to establish how well different dMRI models can predict the ground truth FOD. PMID:26804781

  11. 3D scene reconstruction based on 3D laser point cloud combining UAV images

    NASA Astrophysics Data System (ADS)

    Liu, Huiyun; Yan, Yangyang; Zhang, Xitong; Wu, Zhenzhen

    2016-03-01

    It is a big challenge capturing and modeling 3D information of the built environment. A number of techniques and technologies are now in use. These include GPS, and photogrammetric application and also remote sensing applications. The experiment uses multi-source data fusion technology for 3D scene reconstruction based on the principle of 3D laser scanning technology, which uses the laser point cloud data as the basis and Digital Ortho-photo Map as an auxiliary, uses 3DsMAX software as a basic tool for building three-dimensional scene reconstruction. The article includes data acquisition, data preprocessing, 3D scene construction. The results show that the 3D scene has better truthfulness, and the accuracy of the scene meet the need of 3D scene construction.

  12. [Interest using 3D ultrasound and MRI fusion biopsy for prostate cancer detection].

    PubMed

    Marien, A; De Castro Abreu, A; Gill, I; Villers, A; Ukimura, O

    2017-09-01

    The strategic therapy for prostate cancer depends on histo-pronostics data, which could be upgraded by obtaining targeted biopsies (TB) with MRI (magnetic resonance imagery) fusion 3D ultrasound. To compare diagnostic yield of image fusion guided prostate biopsy using image fusion of multi-parametric MRI (mpMRI) with 3D-TRUS. Between January 2010 and April 2013, 179 consecutive patients underwent outpatient TRUS biopsy using the real-time 3D TRUS tracking system (Urostation™). These patients underwent MRI-TRUS fusion targeted biopsies (TB) with 3D volume data of the MRI elastically fused with 3D TRUS at the time of biopsy. A hundred and seventy-three patients had TBs with fusion. Mean biopsy core per patient were 11.1 (6-14) for SB and 2.4 (1-6) for TB. SBs were positive in 11% compared to 56% for TB (P<0.001). TB outperformed systematic biopsy(SB) in overall any cancer detection rate, detection of clinically significant cancer (58% vs. 36%), cancer core length (6.8mm vs. 2.8mm), and cancer rate per core (P<0.001). In multivariable logistic regression, with TB we have more chance to find a clinically significant cancer (OR:3.72 [2-6.95]). When both TRUS and MRI are positive, there is 2.73 more chance to find a clinically significant cancer. MR/TRUS elastic fusion-guided biopsies outperform systematic random biopsies in diagnosing clinically significant cancer. Ability of interpretation of real-time TRUS is essential to perform the higher level of MR/US fusion and should be use for active surveillance. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. Quantum dot based 3D photonic devices

    NASA Astrophysics Data System (ADS)

    Sakellari, Ioanna; Kabouraki, Elmina; Gray, David; Vamvakaki, Maria; Farsari, Maria

    2017-02-01

    In this work, we present our most recent results on the fabrication of 3D high-resolution woodpile photonic crystals containing an organic-inorganic silicon-zirconium (Si-Zr) composite and cadmium sulfide (CdS) quantum dots (QDs). The structures are fabricated by combining 3D Direct Laser Writing by two-photon absorption and in-situ synthesis of CdS nanoparticles inside the 3D photonic matrix. The CdS-Zr-Si composite material exhibits a high nonlinear refractive index value measured by means of Z-scan method. 3D woodpile photonic structures with varying inlayer periodicity from 600nm to 500nm show clear photonic stop bands in the wavelength region between 1000nm to 450nm.

  14. Individualised 3D printed vaginal template for MRI guided brachytherapy in locally advanced cervical cancer.

    PubMed

    Lindegaard, Jacob Christian; Madsen, Mikkel Lænsø; Traberg, Anders; Meisner, Bjarne; Nielsen, Søren Kynde; Tanderup, Kari; Spejlborg, Harald; Fokdal, Lars Ulrik; Nørrevang, Ole

    2016-01-01

    Intracavitary-interstitial applicators for MRI guided brachytherapy are becoming increasingly important in locally advanced cervical cancer. The 3D printing technology enables a versatile method for obtaining a high degree of individualisation of the implant. Our clinical workflow is presented and exemplified by a stage IVA cervical cancer with superior dose distribution.

  15. Realistic microwave breast models through T1-weighted 3-D MRI data.

    PubMed

    Tunçay, Ahmet Hakan; Akduman, Ibrahim

    2015-02-01

    In this paper we present an effective method for developing realistic numerical three-dimensional (3-D) microwave breast models of different shape, size, and tissue density. These models are especially convenient for microwave breast cancer imaging applications and numerical analysis of human breast-microwave interactions. As in the recent studies on this area, anatomical information of the breast tissue is collected from T1-weighted 3-D MRI data of different patients' in prone position. The method presented in this paper offers significant improvements including efficient noise reduction and tissue segmentation, nonlinear mapping of electromagnetic properties, realistically asymmetric phantom shape, and a realistic classification of breast phantoms. Our method contains a five-step approach where each MRI voxel is classified and mapped to the appropriate dielectric properties. In the first step, the MRI data are denoised by estimating and removing the bias field from each slice, after which the voxels are segmented into two main tissues as fibro-glandular and adipose. Using the distribution of the voxel intensities in MRI histogram, two nonlinear mapping functions are generated for dielectric permittivity and conductivity profiles, which allow each MRI voxel to map to its proper dielectric properties. Obtained dielectric profiles are then converted into 3-D numerical breast phantoms using several image processing techniques, including morphologic operations, filtering. Resultant phantoms are classified according to their adipose content, which is a critical parameter that affects penetration depth during microwave breast imaging.

  16. [Digital modeling for the individual mandibular 3D mesh scaffold based on 3D printing technology].

    PubMed

    Yan, Rongzeng; Luo, Danmei; Qin, Xiaoyu; Li, Runxin; Rong, Qiguo; Hu, Min

    2016-05-01

    To investigate an ideal modeling method of designing 3D mesh scaffold substitutes based on tissue engineering to restore mandibular bone defects. By analyzing the theoretical model from titanium scaffolds fabricated by 3D printing, the feasibility and effectiveness of the proposed methodology were verified. Based on the CT scanned data of a subject, the Mimics 15.0 and Geomagic studio 12.0 reverse engineering software were adopted to generate surface model of mandibular bone and the defect area was separated from the 3D model of bone. Then prosthesis was designed via mirror algorithm, in which outer shape was used as the external shape of scaffold. Unigraphics software NX 8.5 was applied on Boolean calculation of subtraction between prosthesis and regular microstructure structure and ANSYS 14.0 software was used to design the inner construction of 3D mesh scaffolds. The topological structure and the geometrical parameters of 3D mesh titanium scaffolds were adjusted according to the aim of optimized structure and maximal strength with minimal weight. The 3D mesh scaffolds solid model through two kinds of computer-aided methods was input into 3D printing equipment to fabricate titanium scaffolds. Individual scaffolds were designed successfully by two modeling methods. The finite element optimization made 10% decrease of the stress peak and volume decrease of 43%, and the porosity increased to 76.32%. This modeling method was validated by 3D printing titanium scaffold to be feasible and effective. 3D printing technology combined with finite element topology optimization to obtain the ideal mandibular 3D mesh scaffold is feasible and effective.

  17. 3D structure tensor analysis of light microscopy data for validating diffusion MRI.

    PubMed

    Khan, Ahmad Raza; Cornea, Anda; Leigland, Lindsey A; Kohama, Steven G; Jespersen, Sune Nørhøj; Kroenke, Christopher D

    2015-05-01

    Diffusion magnetic resonance imaging (d-MRI) is a powerful non-invasive and non-destructive technique for characterizing brain tissue on the microscopic scale. However, the lack of validation of d-MRI by independent experimental means poses an obstacle to accurate interpretation of data acquired using this method. Recently, structure tensor analysis has been applied to light microscopy images, and this technique holds promise to be a powerful validation strategy for d-MRI. Advantages of this approach include its similarity to d-MRI in terms of averaging the effects of a large number of cellular structures, and its simplicity, which enables it to be implemented in a high-throughput manner. However, a drawback of previous implementations of this technique arises from it being restricted to 2D. As a result, structure tensor analyses have been limited to tissue sectioned in a direction orthogonal to the direction of interest. Here we describe the analytical framework for extending structure tensor analysis to 3D, and utilize the results to analyze serial image "stacks" acquired with confocal microscopy of rhesus macaque hippocampal tissue. Implementation of 3D structure tensor procedures requires removal of sources of anisotropy introduced in tissue preparation and confocal imaging. This is accomplished with image processing steps to mitigate the effects of anisotropic tissue shrinkage, and the effects of anisotropy in the point spread function (PSF). In order to address the latter confound, we describe procedures for measuring the dependence of PSF anisotropy on distance from the microscope objective within tissue. Prior to microscopy, ex vivo d-MRI measurements performed on the hippocampal tissue revealed three regions of tissue with mutually orthogonal directions of least restricted diffusion that correspond to CA1, alveus and inferior longitudinal fasciculus. We demonstrate the ability of 3D structure tensor analysis to identify structure tensor orientations that

  18. 3D structure tensor analysis of light microscopy data for validating diffusion MRI

    PubMed Central

    Khan, Ahmad Raza; Cornea, Anda; Leigland, Lindsey A.; Kohama, Steven G.; Jespersen, Sune Nørhøj; Kroenke, Christopher D.

    2015-01-01

    Diffusion magnetic resonance imaging (d-MRI) is a powerful non-invasive and non-destructive technique for characterizing brain tissue on the microscopic scale. However, the lack of validation of d-MRI by independent experimental means poses an obstacle to accurate interpretation of data acquired using this method. Recently, structure tensor analysis has been applied to light microscopy images, and this technique holds promise to be a powerful validation strategy for d-MRI. Advantages of this approach include its similarity to d-MRI in terms of averaging the effects of a large number of cellular structures, and its simplicity, which enables it to be implemented in a high-throughput manner. However, a drawback of previous implementations of this technique arises from it being restricted to 2D. As a result, structure tensor analyses have been limited to tissue sectioned in a direction orthogonal to the direction of interest. Here we describe the analytical framework for extending structure tensor analysis to 3D, and utilize the results to analyze serial image “stacks” acquired with confocal microscopy of rhesus macaque hippocampal tissue. Implementation of 3D structure tensor procedures requires removal of sources of anisotropy introduced in tissue preparation and confocal imaging. This is accomplished with image processing steps to mitigate the effects of anisotropic tissue shrinkage, and the effects of anisotropy in the point spread function (PSF). In order to address the latter confound, we describe procedures for measuring the dependence of PSF anisotropy on distance from the microscope objective within tissue. Prior to microscopy, ex vivo d-MRI measurements performed on the hippocampal tissue revealed three regions of tissue with mutually orthogonal directions of least restricted diffusion that correspond to CA1, alveus and inferior longitudinal fasciculus. We demonstrate the ability of 3D structure tensor analysis to identify structure tensor orientations

  19. The 3D visualization technology research of submarine pipeline based Horde3D GameEngine

    NASA Astrophysics Data System (ADS)

    Yao, Guanghui; Ma, Xiushui; Chen, Genlang; Ye, Lingjian

    2013-10-01

    With the development of 3D display and virtual reality technology, its application gets more and more widespread. This paper applies 3D display technology to the monitoring of submarine pipeline. We reconstruct the submarine pipeline and its surrounding submarine terrain in computer using Horde3D graphics rendering engine on the foundation database "submarine pipeline and relative landforms landscape synthesis database" so as to display the virtual scene of submarine pipeline based virtual reality and show the relevant data collected from the monitoring of submarine pipeline.

  20. Spherical navigator echoes for full 3D rigid body motion measurement in MRI

    NASA Astrophysics Data System (ADS)

    Welch, Edward B.; Manduca, Armando; Grimm, Roger; Ward, Heidi; Jack, Clifford R.

    2001-07-01

    We are developing a 3-D spherical navigator (SNAV) echo technique for MRI that can measure rigid body motion in all six degrees of freedom simultaneously, in a single echo, by sampling a spherical shell in k-space. MRI pulse sequences were developed to acquire varying amounts of data on such a shell. 3-D rotations of an imaged object simply rotate the data on this shell, and can be detected by registration of magnitude values. 3-D translations add phase shifts to the data on the shell, and can be detected with a weighted least squares fit to the phase differences at corresponding points. Data collected with a computer controlled motion phantom with known rotational and translational motions was used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density, with roughly 1000 sample points necessary for accurate detection to within the error limits of the motion phantom. This number of samples can be captured in a single SNAV echo with a 3-D helical spiral trajectory. Motion detection in MRI with spherical navigator echoes is thus feasible and practical. Accurate motion measurements about all three axes, suitable for retrospective or prospective correction, can be obtained in a single pulse sequence.

  1. MRI depiction and 3D visualization of three anterior cruciate ligament bundles.

    PubMed

    Otsubo, H; Akatsuka, Y; Takashima, H; Suzuki, T; Suzuki, D; Kamiya, T; Ikeda, Y; Matsumura, T; Yamashita, T; Shino, K

    2017-03-01

    The anterior cruciate ligament (ACL) is divided into three fiber bundles (AM-M: anteromedial-medial, AM-L: anteromedial-lateral, PL: posterolateral). We attempted to depict the three bundles of the human ACL on MRI images and to obtain 3-dimensional visualization of them. Twenty-four knees of healthy volunteers (14 males, 10 females) were scanned by 3T-MRI using the fat suppression 3D coherent oscillatory state acquisition for the manipulation of imaging contrast (FS 3D-COSMIC). The scanned images were reconstructed after the isotropic voxel data, which allows the images to be reconstructed in any plane, was acquired. We conducted statistical examination on the identification rate of the three ACL bundles by 2D planes. Segmentation and 3D visualization of the fiber bundles using volume rendering were performed. The triple-bundle ACL was best depicted in the oblique axial plane. While the AM-M and AM-L bundles were clearly depicted in all cases, the PL bundle was not clearly visualized in two knees (8%). Therefore, the three ACL bundles were depicted in 22 knees (92%). The results of 3D visualization of the fiber arrangement agreed well with macroscopic findings of previous anatomical studies. 3T-MRI and the isotropic voxel data from FS 3D-COSMIC made it possible to demonstrate the identifiable depiction of three ACL bundles in nearly all cases. 3D visualization of the bundles could be a useful tool to understand the ACL fiber arrangement. Clin. Anat. 30:276-283, 2017. 2016 The Authors. Clinical Anatomy published by Wiley Periodicals, Inc. on behalf of American Association of Clinical Anatomists.

  2. Pattern based 3D image Steganography

    NASA Astrophysics Data System (ADS)

    Thiyagarajan, P.; Natarajan, V.; Aghila, G.; Prasanna Venkatesan, V.; Anitha, R.

    2013-03-01

    This paper proposes a new high capacity Steganographic scheme using 3D geometric models. The novel algorithm re-triangulates a part of a triangle mesh and embeds the secret information into newly added position of triangle meshes. Up to nine bits of secret data can be embedded into vertices of a triangle without causing any changes in the visual quality and the geometric properties of the cover image. Experimental results show that the proposed algorithm is secure, with high capacity and low distortion rate. Our algorithm also resists against uniform affine transformations such as cropping, rotation and scaling. Also, the performance of the method is compared with other existing 3D Steganography algorithms. [Figure not available: see fulltext.

  3. Temporal bone MRI with 3D-FIESTA in the evaluation of facial and audiovestibular dysfunction.

    PubMed

    Cavusoglu, M; Cılız, D S; Duran, S; Ozsoy, A; Elverici, E; Karaoglanoglu, R; Sakman, B

    2016-09-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) of the temporal bone using three-dimensional fast imaging employing steady-state acquisition (3D-FIESTA) sequences in patients with facial and audiovestibular dysfunction. We retrospectively reviewed the MR images of 1263 patients who presented with hearing loss (n=429), peripheral facial palsy (n=96), tinnitus (n=341) or vertigo (n=397). There were 605 men and 658 women, with a mean age of 46.97±16.95 (SD) years (range: 2-83 years). Positive MRI findings that were responsible for clinical manifestations in individual patients were categorized according to the anatomic sites and etiologies of the lesions. Positive MRI findings possibly responsible for clinical manifestations were found in 232/1263 (18.37%) patients, including 86/429 (20.05%) patients with hearing loss, 21/96 (21.88%) patients with facial palsy, 62/341 (18.18%) patients with tinnitus, and 63/397 (15.87%) patients with vertigo. Although the use of MRI of the temporal bone using 3D-FIESTA shows positive findings in only 18.37% of patients, it provides important information in those with facial and audiovestibular dysfunction. However, for patients with normal MRI of the temporal bone, other etiological factors should be investigated in order to clarify or elucidate the cause of clinical manifestations. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  4. Segmentation and length measurement of the abdominal blood vessels in 3-D MRI images.

    PubMed

    Babin, Danilo; Vansteenkiste, Ewout; Pizurica, Aleksandra; Philips, Wilfried

    2009-01-01

    In diagnosing diseases and planning surgeries the structure and length of blood vessels is of great importance. In this research we develop a novel method for the segmentation of 2-D and 3-D images with an application to blood vessel length measurements in 3-D abdominal MRI images. Our approach is robust to noise and does not require contrast-enhanced images for segmentation. We use an effective algorithm for skeletonization, graph construction and shortest path estimation to measure the length of blood vessels of interest.

  5. 3D fully convolutional networks for subcortical segmentation in MRI: A large-scale study.

    PubMed

    Dolz, Jose; Desrosiers, Christian; Ben Ayed, Ismail

    2017-04-24

    This study investigates a 3D and fully convolutional neural network (CNN) for subcortical brain structure segmentation in MRI. 3D CNN architectures have been generally avoided due to their computational and memory requirements during inference. We address the problem via small kernels, allowing deeper architectures. We further model both local and global context by embedding intermediate-layer outputs in the final prediction, which encourages consistency between features extracted at different scales and embeds fine-grained information directly in the segmentation process. Our model is efficiently trained end-to-end on a graphics processing unit (GPU), in a single stage, exploiting the dense inference capabilities of fully CNNs. We performed comprehensive experiments over two publicly available datasets. First, we demonstrate a state-of-the-art performance on the ISBR dataset. Then, we report a large-scale multi-site evaluation over 1112 unregistered subject datasets acquired from 17 different sites (ABIDE dataset), with ages ranging from 7 to 64 years, showing that our method is robust to various acquisition protocols, demographics and clinical factors. Our method yielded segmentations that are highly consistent with a standard atlas-based approach, while running in a fraction of the time needed by atlas-based methods and avoiding registration/normalization steps. This makes it convenient for massive multi-site neuroanatomical imaging studies. To the best of our knowledge, our work is the first to study subcortical structure segmentation on such large-scale and heterogeneous data. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Automatic 3D segmentation of spinal cord MRI using propagated deformable models

    NASA Astrophysics Data System (ADS)

    De Leener, B.; Cohen-Adad, J.; Kadoury, S.

    2014-03-01

    Spinal cord diseases or injuries can cause dysfunction of the sensory and locomotor systems. Segmentation of the spinal cord provides measures of atrophy and allows group analysis of multi-parametric MRI via inter-subject registration to a template. All these measures were shown to improve diagnostic and surgical intervention. We developed a framework to automatically segment the spinal cord on T2-weighted MR images, based on the propagation of a deformable model. The algorithm is divided into three parts: first, an initialization step detects the spinal cord position and orientation by using the elliptical Hough transform on multiple adjacent axial slices to produce an initial tubular mesh. Second, a low-resolution deformable model is iteratively propagated along the spinal cord. To deal with highly variable contrast levels between the spinal cord and the cerebrospinal fluid, the deformation is coupled with a contrast adaptation at each iteration. Third, a refinement process and a global deformation are applied on the low-resolution mesh to provide an accurate segmentation of the spinal cord. Our method was evaluated against a semi-automatic edge-based snake method implemented in ITK-SNAP (with heavy manual adjustment) by computing the 3D Dice coefficient, mean and maximum distance errors. Accuracy and robustness were assessed from 8 healthy subjects. Each subject had two volumes: one at the cervical and one at the thoracolumbar region. Results show a precision of 0.30 +/- 0.05 mm (mean absolute distance error) in the cervical region and 0.27 +/- 0.06 mm in the thoracolumbar region. The 3D Dice coefficient was of 0.93 for both regions.

  7. Toward the automatic quantification of in utero brain development in 3D structural MRI: A review.

    PubMed

    Benkarim, Oualid M; Sanroma, Gerard; Zimmer, Veronika A; Muñoz-Moreno, Emma; Hahner, Nadine; Eixarch, Elisenda; Camara, Oscar; González Ballester, Miguel Angel; Piella, Gemma

    2017-02-14

    Investigating the human brain in utero is important for researchers and clinicians seeking to understand early neurodevelopmental processes. With the advent of fast magnetic resonance imaging (MRI) techniques and the development of motion correction algorithms to obtain high-quality 3D images of the fetal brain, it is now possible to gain more insight into the ongoing maturational processes in the brain. In this article, we present a review of the major building blocks of the pipeline toward performing quantitative analysis of in vivo MRI of the developing brain and its potential applications in clinical settings. The review focuses on T1- and T2-weighted modalities, and covers state of the art methodologies involved in each step of the pipeline, in particular, 3D volume reconstruction, spatio-temporal modeling of the developing brain, segmentation, quantification techniques, and clinical applications. Hum Brain Mapp, 2017. © 2017 Wiley Periodicals, Inc.

  8. Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery.

    PubMed

    Ipsen, S; Blanck, O; Lowther, N J; Liney, G P; Rai, R; Bode, F; Dunst, J; Schweikard, A; Keall, P J

    2016-11-21

    Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D-2D orthogonal planes (sagittal-coronal, temporal resolution 200-252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was  ⩽  3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D-2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy

  9. Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery

    NASA Astrophysics Data System (ADS)

    Ipsen, S.; Blanck, O.; Lowther, N. J.; Liney, G. P.; Rai, R.; Bode, F.; Dunst, J.; Schweikard, A.; Keall, P. J.

    2016-11-01

    Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D-2D orthogonal planes (sagittal-coronal, temporal resolution 200-252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was  ⩽  3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D-2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy

  10. An efficient and robust 3D mesh compression based on 3D watermarking and wavelet transform

    NASA Astrophysics Data System (ADS)

    Zagrouba, Ezzeddine; Ben Jabra, Saoussen; Didi, Yosra

    2011-06-01

    The compression and watermarking of 3D meshes are very important in many areas of activity including digital cinematography, virtual reality as well as CAD design. However, most studies on 3D watermarking and 3D compression are done independently. To verify a good trade-off between protection and a fast transfer of 3D meshes, this paper proposes a new approach which combines 3D mesh compression with mesh watermarking. This combination is based on a wavelet transformation. In fact, the used compression method is decomposed to two stages: geometric encoding and topologic encoding. The proposed approach consists to insert a signature between these two stages. First, the wavelet transformation is applied to the original mesh to obtain two components: wavelets coefficients and a coarse mesh. Then, the geometric encoding is done on these two components. The obtained coarse mesh will be marked using a robust mesh watermarking scheme. This insertion into coarse mesh allows obtaining high robustness to several attacks. Finally, the topologic encoding is applied to the marked coarse mesh to obtain the compressed mesh. The combination of compression and watermarking permits to detect the presence of signature after a compression of the marked mesh. In plus, it allows transferring protected 3D meshes with the minimum size. The experiments and evaluations show that the proposed approach presents efficient results in terms of compression gain, invisibility and robustness of the signature against of many attacks.

  11. Computer-aided segmentation and 3D analysis of in vivo MRI examinations of the human vocal tract during phonation

    NASA Astrophysics Data System (ADS)

    Wismüller, Axel; Behrends, Johannes; Hoole, Phil; Leinsinger, Gerda L.; Meyer-Baese, Anke; Reiser, Maximilian F.

    2008-03-01

    We developed, tested, and evaluated a 3D segmentation and analysis system for in vivo MRI examinations of the human vocal tract during phonation. For this purpose, six professionally trained speakers, age 22-34y, were examined using a standardized MRI protocol (1.5 T, T1w FLASH, ST 4mm, 23 slices, acq. time 21s). The volunteers performed a prolonged (>=21s) emission of sounds of the German phonemic inventory. Simultaneous audio tape recording was obtained to control correct utterance. Scans were made in axial, coronal, and sagittal planes each. Computer-aided quantitative 3D evaluation included (i) automated registration of the phoneme-specific data acquired in different slice orientations, (ii) semi-automated segmentation of oropharyngeal structures, (iii) computation of a curvilinear vocal tract midline in 3D by nonlinear PCA, (iv) computation of cross-sectional areas of the vocal tract perpendicular to this midline. For the vowels /a/,/e/,/i/,/o/,/ø/,/u/,/y/, the extracted area functions were used to synthesize phoneme sounds based on an articulatory-acoustic model. For quantitative analysis, recorded and synthesized phonemes were compared, where area functions extracted from 2D midsagittal slices were used as a reference. All vowels could be identified correctly based on the synthesized phoneme sounds. The comparison between synthesized and recorded vowel phonemes revealed that the quality of phoneme sound synthesis was improved for phonemes /a/ and /y/, if 3D instead of 2D data were used, as measured by the average relative frequency shift between recorded and synthesized vowel formants (p<0.05, one-sided Wilcoxon rank sum test). In summary, the combination of fast MRI followed by subsequent 3D segmentation and analysis is a novel approach to examine human phonation in vivo. It unveils functional anatomical findings that may be essential for realistic modelling of the human vocal tract during speech production.

  12. 3D MRI Analysis of the Lower Legs of Treated Idiopathic Congenital Talipes Equinovarus (Clubfoot)

    PubMed Central

    Duce, Suzanne L.; D’Alessandro, Mariella; Du, Yimeng; Jagpal, Baljit; Gilbert, Fiona J.; Crichton, Lena; Barker, Simon; Collinson, J. Martin; Miedzybrodzka, Zosia

    2013-01-01

    Background Idiopathic congenital talipes equinovarus (CTEV) is the commonest form of clubfoot. Its exact cause is unknown, although it is related to limb development. The aim of this study was to quantify the anatomy of the muscle, subcutaneous fat, tibia, fibula and arteries in the lower legs of teenagers and young adults with CTEV using 3D magnetic resonance imaging (MRI), and thus to investigate the anatomical differences between CTEV participants and controls. Methodology/Principal Findings The lower legs of six CTEV (2 bilateral, 4 unilateral) and five control young adults (age 12–28) were imaged using a 3T MRI Philips scanner. 5 of the CTEV participants had undergone soft-tissue and capsular release surgery. 3D T1-weighted and 3D magnetic resonance angiography (MRA) images were acquired. Segmentation software was used for volumetric, anatomical and image analysis. Kolmogorov-Smirnov tests were performed. The volumes of the lower affected leg, muscle, tibia and fibula in unilateral CTEV participants were consistently smaller compared to their contralateral unaffected leg, this was most pronounced in muscle. The proportion of muscle in affected CTEV legs was significantly reduced compared with control and unaffected CTEV legs, whilst proportion of muscular fat increased. No spatial abnormalities in the location or branching of arteries were detected, but hypoplastic anomalies were observed. Conclusions/Significance Combining 3D MRI and MRA is effective for quantitatively characterizing CTEV anatomy. Reduction in leg muscle volume appears to be a sensitive marker. Since 5/6 CTEV cases had soft-tissue surgery, further work is required to confirm that the treatment did not affect the MRI features observed. We propose that the proportion of muscle and intra-muscular fat within the lower leg could provide a valuable addition to current clinical CTEV classification. These measures could be useful for clinical care and guiding treatment pathways, as well as

  13. 3D MRI analysis of the lower legs of treated idiopathic congenital talipes equinovarus (clubfoot).

    PubMed

    Duce, Suzanne L; D'Alessandro, Mariella; Du, Yimeng; Jagpal, Baljit; Gilbert, Fiona J; Crichton, Lena; Barker, Simon; Collinson, J Martin; Miedzybrodzka, Zosia

    2013-01-01

    Idiopathic congenital talipes equinovarus (CTEV) is the commonest form of clubfoot. Its exact cause is unknown, although it is related to limb development. The aim of this study was to quantify the anatomy of the muscle, subcutaneous fat, tibia, fibula and arteries in the lower legs of teenagers and young adults with CTEV using 3D magnetic resonance imaging (MRI), and thus to investigate the anatomical differences between CTEV participants and controls. The lower legs of six CTEV (2 bilateral, 4 unilateral) and five control young adults (age 12-28) were imaged using a 3T MRI Philips scanner. 5 of the CTEV participants had undergone soft-tissue and capsular release surgery. 3D T1-weighted and 3D magnetic resonance angiography (MRA) images were acquired. Segmentation software was used for volumetric, anatomical and image analysis. Kolmogorov-Smirnov tests were performed. The volumes of the lower affected leg, muscle, tibia and fibula in unilateral CTEV participants were consistently smaller compared to their contralateral unaffected leg, this was most pronounced in muscle. The proportion of muscle in affected CTEV legs was significantly reduced compared with control and unaffected CTEV legs, whilst proportion of muscular fat increased. No spatial abnormalities in the location or branching of arteries were detected, but hypoplastic anomalies were observed. Combining 3D MRI and MRA is effective for quantitatively characterizing CTEV anatomy. Reduction in leg muscle volume appears to be a sensitive marker. Since 5/6 CTEV cases had soft-tissue surgery, further work is required to confirm that the treatment did not affect the MRI features observed. We propose that the proportion of muscle and intra-muscular fat within the lower leg could provide a valuable addition to current clinical CTEV classification. These measures could be useful for clinical care and guiding treatment pathways, as well as treatment research and clinical audit.

  14. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI.

    PubMed

    Nordeck, Shaun M; Koerper, Conrad E; Adler, Aaron; Malhotra, Vidur; Xi, Yin; Liu, George T; Chhabra, Avneesh

    2017-05-01

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR.

  15. Computer-aided diagnosis of breast DCE-MRI using pharmacokinetic model and 3-D morphology analysis.

    PubMed

    Wang, Teh-Chen; Huang, Yan-Hao; Huang, Chiun-Sheng; Chen, Jeon-Hor; Huang, Guei-Yu; Chang, Yeun-Chung; Chang, Ruey-Feng

    2014-04-01

    Three-dimensional (3-D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) consists of a large number of images in different enhancement phases which are used to identify and characterize breast lesions. The purpose of this study was to develop a computer-assisted algorithm for tumor segmentation and characterization using both kinetic information and morphological features of 3-D breast DCE-MRI. An integrated color map created by intersecting kinetic and area under the curve (AUC) color maps was used to detect potential breast lesions, followed by the application of a region growing algorithm to segment the tumor. Modified fuzzy c-means clustering was used to identify the most representative kinetic curve of the whole segmented tumor, which was then characterized by using conventional curve analysis or pharmacokinetic model. The 3-D morphological features including shape features (compactness, margin, and ellipsoid fitting) and texture features (based on the grey level co-occurrence matrix) of the segmented tumor were obtained to characterize the lesion. One hundred and thirty-two biopsy-proven lesions (63 benign and 69 malignant) were used to evaluate the performance of the proposed computer-aided system for breast MRI. Five combined features including rate constant (kep), volume of plasma (vp), energy (G1), entropy (G2), and compactness (C1), had the best performance with an accuracy of 91.67% (121/132), sensitivity of 91.30% (63/69), specificity of 92.06% (58/63), and Az value of 0.9427. Combining the kinetic and morphological features of 3-D breast MRI is a potentially useful and robust algorithm when attempting to differentiate benign and malignant lesions.

  16. Assessment of cerebral blood perfusion reserve with acetazolamide using 3D spiral ASL MRI: Preliminary experience in pediatric patients.

    PubMed

    Hu, Houchun H; Li, Zhiqiang; Pokorney, Amber L; Chia, Jonathan M; Stefani, Niccolo; Pipe, James G; Miller, Jeffrey H

    2017-01-01

    To demonstrate the clinical feasibility of a new non-Cartesian cylindrically-distributed spiral 3D pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging (MRI) pulse sequence in pediatric patients in quantifying cerebral blood flow (CBF) response to an acetazolamide (ACZ) vasodilator challenge. MRI exams were performed on two 3 Tesla Philips Ingenia systems using 32 channel head coil arrays. After local institutional review board approval, the 3D spiral-based pCASL technique was added to a standard brain MRI exam and evaluated in 13 pediatric patients (average age: 11.7±6.4years, range: 1.4-22.2years). All patients were administered ACZ for clinically indicated reasons. Quantitative whole-brain CBF measurements were computed pre- and post-ACZ to assess cerebrovascular reserve. 3D spiral pCASL data were successfully reconstructed in all 13 cases. In 11 patients, CBF increased 2.8% to 93.2% after administration of ACZ. In the two remaining patients, CBF decreased by 2.4 to 6.0% after ACZ. The group average change in CBF due to ACZ was approximately 25.0% and individual changes were statistically significant (p<0.01) in all patients using a paired t-test analysis. CBF perfusion data were diagnostically useful in supporting conventional MR angiography and clinical findings. 3D cylindrically-distributed spiral pCASL MRI provides a robust approach to assess cerebral blood flow and reserve in pediatric patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. 3D Motion Modeling and Reconstruction of Left Ventricle Wall in Cardiac MRI.

    PubMed

    Yang, Dong; Wu, Pengxiang; Tan, Chaowei; Pohl, Kilian M; Axel, Leon; Metaxas, Dimitris

    2017-06-01

    The analysis of left ventricle (LV) wall motion is a critical step for understanding cardiac functioning mechanisms and clinical diagnosis of ventricular diseases. We present a novel approach for 3D motion modeling and analysis of LV wall in cardiac magnetic resonance imaging (MRI). First, a fully convolutional network (FCN) is deployed to initialize myocardium contours in 2D MR slices. Then, we propose an image registration algorithm to align MR slices in space and minimize the undesirable motion artifacts from inconsistent respiration. Finally, a 3D deformable model is applied to recover the shape and motion of myocardium wall. Utilizing the proposed approach, we can visually analyze 3D LV wall motion, evaluate cardiac global function, and diagnose ventricular diseases.

  18. MRI-Derived 3-D-Printed Breast Phantom for Microwave Breast Imaging Validation.

    PubMed

    Burfeindt, Matthew J; Colgan, Timothy J; Mays, R Owen; Shea, Jacob D; Behdad, Nader; Van Veen, Barry D; Hagness, Susan C

    2012-01-01

    We propose a 3-D-printed breast phantom for use in preclinical experimental microwave imaging studies. The phantom is derived from an MRI of a human subject; thus, it is anthropomorphic, and its interior is very similar to an actual distribution of fibroglandular tissues. Adipose tissue in the breast is represented by the solid plastic (printed) regions of the phantom, while fibroglandular tissue is represented by liquid-filled voids in the plastic. The liquid is chosen to provide a biologically relevant dielectric contrast with the printed plastic. Such a phantom enables validation of microwave imaging techniques. We describe the procedure for generating the 3-D-printed breast phantom and present the measured dielectric properties of the 3-D-printed plastic over the frequency range 0.5-3.5 GHz. We also provide an example of a suitable liquid for filling the fibroglandular voids in the plastic.

  19. MRI-Derived 3-D-Printed Breast Phantom for Microwave Breast Imaging Validation

    PubMed Central

    Burfeindt, Matthew J.; Colgan, Timothy J.; Mays, R. Owen; Shea, Jacob D.; Behdad, Nader; Van Veen, Barry D.; Hagness, Susan C.

    2014-01-01

    We propose a 3-D-printed breast phantom for use in preclinical experimental microwave imaging studies. The phantom is derived from an MRI of a human subject; thus, it is anthropomorphic, and its interior is very similar to an actual distribution of fibroglandular tissues. Adipose tissue in the breast is represented by the solid plastic (printed) regions of the phantom, while fibroglandular tissue is represented by liquid-filled voids in the plastic. The liquid is chosen to provide a biologically relevant dielectric contrast with the printed plastic. Such a phantom enables validation of microwave imaging techniques. We describe the procedure for generating the 3-D-printed breast phantom and present the measured dielectric properties of the 3-D-printed plastic over the frequency range 0.5–3.5 GHz. We also provide an example of a suitable liquid for filling the fibroglandular voids in the plastic. PMID:25132808

  20. 3D mapping of somatotopic reorganization with small animal functional MRI

    PubMed Central

    Yu, Xin; Wang, Shumin; Chen, Der-Yow; Dodd, Stephen; Goloshevsky, Artem; Koretsky, Alan P.

    2009-01-01

    There are few in vivo noninvasive methods to study neuroplasticity in animal brains. Functional MRI (fMRI) has been developed for animal brain mapping, but few fMRI studies have analyzed functional alteration due to plasticity in animal models. One major limitation is that fMRI maps are characterized by statistical parametric mapping making the apparent boundary dependent on the statistical threshold used. Here, we developed a method to characterize the location of center-of-mass in fMRI maps that is shown not to be sensitive to statistical threshold. Utilizing centers-of-mass as anchor points to fit the spatial distribution of the BOLD response enabled quantitative group analysis of altered boundaries of functional somatosensory maps. This approach was used to study cortical reorganization in the rat primary somatosensory cortex (S1) after sensory deprivation to the barrel cortex by follicle ablation (F.A.). FMRI demonstrated an enlarged nose S1 representation in the 3D somatotopic functional maps. This result clearly demonstrates that fMRI enables the spatial mapping of functional changes that can characterize multiple regions of S1 cortex and still be sensitive to changes due to plasticity. PMID:19770051

  1. Utilizing 3D Printing Technology to Merge MRI with Histology: A Protocol for Brain Sectioning

    PubMed Central

    Luciano, Nicholas J; Sati, Pascal; Nair, Govind; Guy, Joseph R; Ha, Seung-Kwon; Absinta, Martina; Chiang, Wen-Yang; Leibovitch, Emily C; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S.

    2016-01-01

    Magnetic resonance imaging (MRI) allows for the delineation between normal and abnormal tissue on a macroscopic scale, sampling an entire tissue volume three-dimensionally. While MRI is an extremely sensitive tool for detecting tissue abnormalities, association of signal changes with an underlying pathological process is usually not straightforward. In the central nervous system, for example, inflammation, demyelination, axonal damage, gliosis, and neuronal death may all induce similar findings on MRI. As such, interpretation of MRI scans depends on the context, and radiological-histopathological correlation is therefore of the utmost importance. Unfortunately, traditional pathological sectioning of brain tissue is often imprecise and inconsistent, thus complicating the comparison between histology sections and MRI. This article presents novel methodology for accurately sectioning primate brain tissues and thus allowing precise matching between histology and MRI. The detailed protocol described in this article will assist investigators in applying this method, which relies on the creation of 3D printed brain slicers. Slightly modified, it can be easily implemented for brains of other species, including humans. PMID:28060281

  2. Utilizing 3D Printing Technology to Merge MRI with Histology: A Protocol for Brain Sectioning.

    PubMed

    Luciano, Nicholas J; Sati, Pascal; Nair, Govind; Guy, Joseph R; Ha, Seung-Kwon; Absinta, Martina; Chiang, Wen-Yang; Leibovitch, Emily C; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-12-06

    Magnetic resonance imaging (MRI) allows for the delineation between normal and abnormal tissue on a macroscopic scale, sampling an entire tissue volume three-dimensionally. While MRI is an extremely sensitive tool for detecting tissue abnormalities, association of signal changes with an underlying pathological process is usually not straightforward. In the central nervous system, for example, inflammation, demyelination, axonal damage, gliosis, and neuronal death may all induce similar findings on MRI. As such, interpretation of MRI scans depends on the context, and radiological-histopathological correlation is therefore of the utmost importance. Unfortunately, traditional pathological sectioning of brain tissue is often imprecise and inconsistent, thus complicating the comparison between histology sections and MRI. This article presents novel methodology for accurately sectioning primate brain tissues and thus allowing precise matching between histology and MRI. The detailed protocol described in this article will assist investigators in applying this method, which relies on the creation of 3D printed brain slicers. Slightly modified, it can be easily implemented for brains of other species, including humans.

  3. Reconstruction and 3D visualisation based on objective real 3D based documentation.

    PubMed

    Bolliger, Michael J; Buck, Ursula; Thali, Michael J; Bolliger, Stephan A

    2012-09-01

    Reconstructions based directly upon forensic evidence alone are called primary information. Historically this consists of documentation of findings by verbal protocols, photographs and other visual means. Currently modern imaging techniques such as 3D surface scanning and radiological methods (computer tomography, magnetic resonance imaging) are also applied. Secondary interpretation is based on facts and the examiner's experience. Usually such reconstructive expertises are given in written form, and are often enhanced by sketches. However, narrative interpretations can, especially in complex courses of action, be difficult to present and can be misunderstood. In this report we demonstrate the use of graphic reconstruction of secondary interpretation with supporting pictorial evidence, applying digital visualisation (using 'Poser') or scientific animation (using '3D Studio Max', 'Maya') and present methods of clearly distinguishing between factual documentation and examiners' interpretation based on three cases. The first case involved a pedestrian who was initially struck by a car on a motorway and was then run over by a second car. The second case involved a suicidal gunshot to the head with a rifle, in which the trigger was pushed with a rod. The third case dealt with a collision between two motorcycles. Pictorial reconstruction of the secondary interpretation of these cases has several advantages. The images enable an immediate overview, give rise to enhanced clarity, and compel the examiner to look at all details if he or she is to create a complete image.

  4. 3D conformal MRI-guided transurethral ultrasound therapy: results of gel phantom experiments

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Burtnyk, M.; McCormick, S.; Bronskill, M.; Chopra, R.

    2011-09-01

    MRI-guided transurethral ultrasound therapy shows promise for minimally invasive treatment of localized prostate cancer. Previous in-vivo studies demonstrated the feasibility of performing conservative treatments using real-time temperature feedback to control accurately the establishment of coagulative lesions within circumscribed prostate regions. This in-vitro study tested device configuration and control options for achieving full prostate treatments. A multi-channel MRI compatible ultrasound therapy system was evaluated in gel phantoms using 3 canine prostate models. Prostate profiles were 5 mm-step-segmented from T2-weighted MR images performed during previous in-vivo experiments. During ultrasound exposures, each ultrasound element was controlled independently by the 3D controller. Decisions on acoustic power, frequency, and device rotation rate were made in real time based on MR thermometry feedback and prostate radii. Low and high power treatment approaches using maximum acoustic powers of 10 or 20 W.cm-2 were tested as well as single and dual-frequency strategies (4.05/13.10 MHz). The dual-frequency strategy used either the fundamental frequency or the 3rd harmonic component, depending on the prostate radius. The 20 W.cm-2 dual frequency approach was the most efficient configuration in achieving full prostate treatments. Treatment times were about half the duration of those performed with 10 W.cm-2 configurations. Full prostate coagulations were performed in 16.3±6.1 min at a rate of 1.8±0.2 cm3.min-1, and resulted in very little undertreated tissue (<3%). Surrounding organs positioned beyond a safety distance of 1.4±1.0 mm from prostate boundaries were not damaged, particularly rectal wall tissues. In this study, a 3D, MR-thermometry-guided transurethral ultrasound therapy was validated in vitro in a tissue-mimicking phantom for performing full prostate treatment. A dual-frequency configuration with 20 W.cm-2 ultrasound intensity exposure showed good

  5. 3D-FT thin sections MRI of prolactin-secreting pituitary microadenomas.

    PubMed

    Girard, N; Brue, T; Chabert-Orsini, V; Raybaud, C; Jaquet, P; Poncet, M; Grisoli, F; Cahen, S

    1994-07-01

    We studied 76 patients with endocrinological features of prolactin-secreting microadenoma by MRI, using three dimensional (3D) gradient echo acquisition (FLASH) sequences. MRI revealed a focal signal abnormality in the pituitary in all 37 patients who had not previously taken bromocriptine. However, focal abnormality was shown in only half the patients had been on dopamine agonist therapy; the MRI findings in these 39 patients were not affected by the duration and dosage bromocriptine, nor by the time elapsed since its discontinuation. The microadenoma gave spontaneous high signal on the unenhanced T1-weighted images in 8 cases; it was not seen on unenhanced images in 25 cases. It appeared as low signal within the enhancing gland in 51 cases but enhanced in 7 cases. The 3D technique gives thin (1 mm) slices and therefore facilitates detection of small focal abnormalities in the pituitary gland (2 x 2 mm). In the 19 previously treated patients in whom MRI did not demonstrate a focal abnormality, it showed localised atrophy of the gland in 3, a large, round gland with homogeneous signal in 1, and a heterogeneous appearance in 11; it was normal in 4 cases.

  6. Real-time 3D imaging of microstructure growth in battery cells using indirect MRI

    PubMed Central

    Ilott, Andrew J.; Mohammadi, Mohaddese; Chang, Hee Jung; Grey, Clare P.; Jerschow, Alexej

    2016-01-01

    Lithium metal is a promising anode material for Li-ion batteries due to its high theoretical specific capacity and low potential. The growth of dendrites is a major barrier to the development of high capacity, rechargeable Li batteries with lithium metal anodes, and hence, significant efforts have been undertaken to develop new electrolytes and separator materials that can prevent this process or promote smooth deposits at the anode. Central to these goals, and to the task of understanding the conditions that initiate and propagate dendrite growth, is the development of analytical and nondestructive techniques that can be applied in situ to functioning batteries. MRI has recently been demonstrated to provide noninvasive imaging methodology that can detect and localize microstructure buildup. However, until now, monitoring dendrite growth by MRI has been limited to observing the relatively insensitive metal nucleus directly, thus restricting the temporal and spatial resolution and requiring special hardware and acquisition modes. Here, we present an alternative approach to detect a broad class of metallic dendrite growth via the dendrites’ indirect effects on the surrounding electrolyte, allowing for the application of fast 3D 1H MRI experiments with high resolution. We use these experiments to reconstruct 3D images of growing Li dendrites from MRI, revealing details about the growth rate and fractal behavior. Radiofrequency and static magnetic field calculations are used alongside the images to quantify the amount of the growing structures. PMID:27621444

  7. Whole lung morphometry with 3D multiple b-value hyperpolarized gas MRI and compressed sensing.

    PubMed

    Chan, Ho-Fung; Stewart, Neil J; Parra-Robles, Juan; Collier, Guilhem J; Wild, Jim M

    2017-05-01

    To demonstrate three-dimensional (3D) multiple b-value diffusion-weighted (DW) MRI of hyperpolarized (3) He gas for whole lung morphometry with compressed sensing (CS). A fully-sampled, two b-value, 3D hyperpolarized (3) He DW-MRI dataset was acquired from the lungs of a healthy volunteer and retrospectively undersampled in the ky and kz phase-encoding directions for CS simulations. Optimal k-space undersampling patterns were determined by minimizing the mean absolute error between reconstructed and fully-sampled (3) He apparent diffusion coefficient (ADC) maps. Prospective three-fold, undersampled, 3D multiple b-value (3) He DW-MRI datasets were acquired from five healthy volunteers and one chronic obstructive pulmonary disease (COPD) patient, and the mean values of maps of ADC and mean alveolar dimension (LmD ) were validated against two-dimensional (2D) and 3D fully-sampled (3) He DW-MRI experiments. Reconstructed undersampled datasets showed no visual artifacts and good preservation of the main image features and quantitative information. A good agreement between fully-sampled and prospective undersampled datasets was found, with a mean difference of +3.4% and +5.1% observed in mean global ADC and LmD values, respectively. These differences were within the standard deviation range and consistent with values reported from healthy and COPD lungs. Accelerated CS acquisition has facilitated 3D multiple b-value (3) He DW-MRI scans in a single breath-hold, enabling whole lung morphometry mapping. Magn Reson Med 77:1916-1925, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals

  8. 3D Porphyrin-Based Covalent Organic Frameworks.

    PubMed

    Lin, Guiqing; Ding, Huimin; Chen, Rufan; Peng, Zhengkang; Wang, Baoshan; Wang, Cheng

    2017-06-28

    The design and synthesis of three-dimensional covalent organic frameworks (3D COFs) bearing photoelectric units have been considered as a big challenge. Herein, for the first time, we reported the targeted synthesis of two 3D porphyrin-based COFs (3D-Por-COF and 3D-CuPor-COF), starting from tetrahedral (3D-Td) and square (2D-C4) building blocks connected through [4 + 4] imine condensation reactions. On the basis of structural characterizations, 3D-Por-COF and 3D-CuPor-COF are microporous materials with high surface areas, and are proposed to adopt a 2-fold interpenetrated pts topology with Pmc21 space group. Interestingly, both 3D COFs are photosensitive and can be used as heterogeneous catalyst for generating singlet oxygen under photoirradiation. However, 3D-Por-COF shows enhanced photocatalytic activity compared with 3D-CuPor-COF, indicating the properties of 3D porphyrin-based COFs can be tuned by metalation of porphyrin rings. The results reported here will greatly inspire us to design and synthesize 3D COFs bearing other metalloporphyrins for interesting applications (e.g., catalysis) in the future.

  9. Knee cartilage extraction and bone-cartilage interface analysis from 3D MRI data sets

    NASA Astrophysics Data System (ADS)

    Tamez-Pena, Jose G.; Barbu-McInnis, Monica; Totterman, Saara

    2004-05-01

    This works presents a robust methodology for the analysis of the knee joint cartilage and the knee bone-cartilage interface from fused MRI sets. The proposed approach starts by fusing a set of two 3D MR images the knee. Although the proposed method is not pulse sequence dependent, the first sequence should be programmed to achieve good contrast between bone and cartilage. The recommended second pulse sequence is one that maximizes the contrast between cartilage and surrounding soft tissues. Once both pulse sequences are fused, the proposed bone-cartilage analysis is done in four major steps. First, an unsupervised segmentation algorithm is used to extract the femur, the tibia, and the patella. Second, a knowledge based feature extraction algorithm is used to extract the femoral, tibia and patellar cartilages. Third, a trained user corrects cartilage miss-classifications done by the automated extracted cartilage. Finally, the final segmentation is the revisited using an unsupervised MAP voxel relaxation algorithm. This final segmentation has the property that includes the extracted bone tissue as well as all the cartilage tissue. This is an improvement over previous approaches where only the cartilage was segmented. Furthermore, this approach yields very reproducible segmentation results in a set of scan-rescan experiments. When these segmentations were coupled with a partial volume compensated surface extraction algorithm the volume, area, thickness measurements shows precisions around 2.6%

  10. Identifying positioning-based attacks against 3D printed objects and the 3D printing process

    NASA Astrophysics Data System (ADS)

    Straub, Jeremy

    2017-05-01

    Zeltmann, et al. demonstrated that structural integrity and other quality damage to objects can be caused by changing its position on a 3D printer's build plate. On some printers, for example, object surfaces and support members may be stronger when oriented parallel to the X or Y axis. The challenge presented by the need to assure 3D printed object orientation is that this can be altered in numerous places throughout the system. This paper considers attack scenarios and discusses where attacks that change printing orientation can occur in the process. An imaging-based solution to combat this problem is presented.

  11. Classification of clinical significance of MRI prostate findings using 3D convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Mehrtash, Alireza; Sedghi, Alireza; Ghafoorian, Mohsen; Taghipour, Mehdi; Tempany, Clare M.; Wells, William M.; Kapur, Tina; Mousavi, Parvin; Abolmaesumi, Purang; Fedorov, Andriy

    2017-03-01

    Prostate cancer (PCa) remains a leading cause of cancer mortality among American men. Multi-parametric magnetic resonance imaging (mpMRI) is widely used to assist with detection of PCa and characterization of its aggressiveness. Computer-aided diagnosis (CADx) of PCa in MRI can be used as clinical decision support system to aid radiologists in interpretation and reporting of mpMRI. We report on the development of a convolution neural network (CNN) model to support CADx in PCa based on the appearance of prostate tissue in mpMRI, conducted as part of the SPIE-AAPM-NCI PROSTATEx challenge. The performance of different combinations of mpMRI inputs to CNN was assessed and the best result was achieved using DWI and DCE-MRI modalities together with the zonal information of the finding. On the test set, the model achieved an area under the receiver operating characteristic curve of 0.80.

  12. 3D multifocus astigmatism and compressed sensing (3D MACS) based superresolution reconstruction

    PubMed Central

    Huang, Jiaqing; Sun, Mingzhai; Gumpper, Kristyn; Chi, Yuejie; Ma, Jianjie

    2015-01-01

    Single molecule based superresolution techniques (STORM/PALM) achieve nanometer spatial resolution by integrating the temporal information of the switching dynamics of fluorophores (emitters). When emitter density is low for each frame, they are located to the nanometer resolution. However, when the emitter density rises, causing significant overlapping, it becomes increasingly difficult to accurately locate individual emitters. This is particularly apparent in three dimensional (3D) localization because of the large effective volume of the 3D point spread function (PSF). The inability to precisely locate the emitters at a high density causes poor temporal resolution of localization-based superresolution technique and significantly limits its application in 3D live cell imaging. To address this problem, we developed a 3D high-density superresolution imaging platform that allows us to precisely locate the positions of emitters, even when they are significantly overlapped in three dimensional space. Our platform involves a multi-focus system in combination with astigmatic optics and an ℓ1-Homotopy optimization procedure. To reduce the intrinsic bias introduced by the discrete formulation of compressed sensing, we introduced a debiasing step followed by a 3D weighted centroid procedure, which not only increases the localization accuracy, but also increases the computation speed of image reconstruction. We implemented our algorithms on a graphic processing unit (GPU), which speeds up processing 10 times compared with central processing unit (CPU) implementation. We tested our method with both simulated data and experimental data of fluorescently labeled microtubules and were able to reconstruct a 3D microtubule image with 1000 frames (512×512) acquired within 20 seconds. PMID:25798314

  13. Random-profiles-based 3D face recognition system.

    PubMed

    Kim, Joongrock; Yu, Sunjin; Lee, Sangyoun

    2014-03-31

    In this paper, a noble nonintrusive three-dimensional (3D) face modeling system for random-profile-based 3D face recognition is presented. Although recent two-dimensional (2D) face recognition systems can achieve a reliable recognition rate under certain conditions, their performance is limited by internal and external changes, such as illumination and pose variation. To address these issues, 3D face recognition, which uses 3D face data, has recently received much attention. However, the performance of 3D face recognition highly depends on the precision of acquired 3D face data, while also requiring more computational power and storage capacity than 2D face recognition systems. In this paper, we present a developed nonintrusive 3D face modeling system composed of a stereo vision system and an invisible near-infrared line laser, which can be directly applied to profile-based 3D face recognition. We further propose a novel random-profile-based 3D face recognition method that is memory-efficient and pose-invariant. The experimental results demonstrate that the reconstructed 3D face data consists of more than 50 k 3D point clouds and a reliable recognition rate against pose variation.

  14. Random-Profiles-Based 3D Face Recognition System

    PubMed Central

    Joongrock, Kim; Sunjin, Yu; Sangyoun, Lee

    2014-01-01

    In this paper, a noble nonintrusive three-dimensional (3D) face modeling system for random-profile-based 3D face recognition is presented. Although recent two-dimensional (2D) face recognition systems can achieve a reliable recognition rate under certain conditions, their performance is limited by internal and external changes, such as illumination and pose variation. To address these issues, 3D face recognition, which uses 3D face data, has recently received much attention. However, the performance of 3D face recognition highly depends on the precision of acquired 3D face data, while also requiring more computational power and storage capacity than 2D face recognition systems. In this paper, we present a developed nonintrusive 3D face modeling system composed of a stereo vision system and an invisible near-infrared line laser, which can be directly applied to profile-based 3D face recognition. We further propose a novel random-profile-based 3D face recognition method that is memory-efficient and pose-invariant. The experimental results demonstrate that the reconstructed 3D face data consists of more than 50 k 3D point clouds and a reliable recognition rate against pose variation. PMID:24691101

  15. Anatomy-based 3D skeleton extraction from femur model.

    PubMed

    Gharenazifam, Mina; Arbabi, Ehsan

    2014-11-01

    Using 3D models of bones can highly improve accuracy and reliability of orthopaedic evaluation. However, it may impose excessive computational load. This article proposes a fully automatic method for extracting a compact model of the femur from its 3D model. The proposed method works by extracting a 3D skeleton based on the clinical parameters of the femur. Therefore, in addition to summarizing a 3D model of the bone, the extracted skeleton would preserve important clinical and anatomical information. The proposed method has been applied on 3D models of 10 femurs and the results have been evaluated for different resolutions of data.

  16. Diagnostic Value of 3D Fast Low-Angle Shot Dynamic MRI of Breast Papillomas

    PubMed Central

    Kim, Eun-Kyung; Kim, Jeong-Ah; Kwak, Jin Young; Jeong, Joon

    2009-01-01

    Purpose To evaluate the value of breast MRI in analysis of papillomas of the breast. Materials and Methods From 1996 to 2004, 94 patients underwent surgery due to papillomas of the breast. Among them, 21 patients underwent 3D fast low angle shot (FLASH) dynamic breast MRI. Eight masses were palpable and 11 of 21 patients had nipple discharge. Two radiologists indifferently analyzed the location, size of the lesions and shape, margin of the masses, multiplicity and ductal relation. The MRI findings were categorized according to breast imaging reporting and data system (BI-RADS) lexicon. The amount and pattern of enhancement and associated findings were also evaluated according to BI-RADS. We then compared the MRI findings with galactography, mammography and breast ultrasonography (US) and examined histopathologic correlation. Results On breast MRI, the lesion size was 0.4-1.59 cm, and 18 patients showed subareolar location. On 4.25 cm (mean 1.54) dynamic enhanced images, imaging findings showed mass (n = 10), intracystic mass (n = 3), focus (n = 5), ductal enhancement (n = 2), and segmental enhancement (n = 1). In cases of the masses, the shapes of the masses were round (n = 4), lobulated (n = 3), and irregular (n = 6), and margins were circumscribed (n = 6), microlobulated (n = 5), and indistinct (n = 2). The enhancement patterns were homogeneous enhancement (n = 7), heterogeneous (n = 3) or rim enhancement (n = 3). Conclusion The contrast enhanced dynamic breast MRI was highly sensitive for diagnosis of breast papillomas. MRI could play a key role in the pre-operative work-up for multiple papillomas and papillomatosis. PMID:20046427

  17. 3D spiral cardiac/respiratory ordered fMRI data acquisition at 3 Tesla.

    PubMed

    Stenger, V A; Peltier, S; Boada, F E; Noll, D C

    1999-05-01

    Three-dimensional (3D), multi-shot functional magnetic resonance imaging (fMRI) data acquisitions are desirable because of higher resolution and reduced susceptibility artifacts, due to shorter readouts and thinner slices. However, 3D multi-shot techniques are more susceptible to physiological noise, which can increase inter-image variance and lead to inaccurate assessment of activation. This work presents a 3D spiral fMRI data acquisition method at 3 T in which the acquisition of views was ordered to match the phase of either the respiratory or the cardiac cycle. For the acquisition timing parameters used in this work, cardiac ordering was found to reduce inter-image variance by 19%. Cardiac ordered data acquisitions showed the same reduction in variance as sequentially ordered data with cardiac contributions estimated and removed using an externally acquired reference prior to reconstruction. Respiratory ordering showed no reduction in fluctuation noise due to poor alignment of views to the respiratory phase.

  18. MRI assessment of internal acoustic canal variations using 3D-FIESTA sequences.

    PubMed

    Erdogan, Nezahat; Altay, Canan; Akay, Emrah; Karakas, Levent; Uluc, Engin; Mete, Berna; Oygen, Aysegul; Oyar, Orhan; Gelal, Fazıl; Songu, Murat; Katilmis, Huseyin; Calli, Cağlar

    2013-02-01

    Magnetic resonance imaging (MRI) of the internal acoustic canal is the standard diagnostic tool for a wide range of indications in patients. This study aims to investigate the vascular variations and compression of the cranial nerves (CNs) VII and VIII at the cerebellopontine angle in patients with neuro-otologic symptoms using 3D-fast imaging employing steady-state acquisition (FIESTA) MR imaging. One hundred and eighty-seven patients (374 temporal bones) were examined on a 1.5-T MRI. In addition to conventional MR sequences, a 3D-FIESTA MR imaging was acquired. Magnetic resonance images thus obtained were evaluated with special regard to the presence of vascular contact to the CNs VII and VIII, as well as the presence of the vascular variations of the anterior inferior cerebellar artery (AICA) causing the compression of CNs. The Chi-squared test was used for statistical analysis. No statistically significant differences were found between the presence and absence of the AICA loop and/or vascular contact for the clinical symptoms of patients (P > 0.05). The cisternal and canalicular segments of CNs VII and VIII and adjacent vascular variations are well identified using 3D-FIESTA, especially by determining the relationship of the AICA variations between CNs.

  19. Augmented reality 3D display based on integral imaging

    NASA Astrophysics Data System (ADS)

    Deng, Huan; Zhang, Han-Le; He, Min-Yang; Wang, Qiong-Hua

    2017-02-01

    Integral imaging (II) is a good candidate for augmented reality (AR) display, since it provides various physiological depth cues so that viewers can freely change the accommodation and convergence between the virtual three-dimensional (3D) images and the real-world scene without feeling any visual discomfort. We propose two AR 3D display systems based on the theory of II. In the first AR system, a micro II display unit reconstructs a micro 3D image, and the mciro-3D image is magnified by a convex lens. The lateral and depth distortions of the magnified 3D image are analyzed and resolved by the pitch scaling and depth scaling. The magnified 3D image and real 3D scene are overlapped by using a half-mirror to realize AR 3D display. The second AR system uses a micro-lens array holographic optical element (HOE) as an image combiner. The HOE is a volume holographic grating which functions as a micro-lens array for the Bragg-matched light, and as a transparent glass for Bragg mismatched light. A reference beam can reproduce a virtual 3D image from one side and a reference beam with conjugated phase can reproduce the second 3D image from other side of the micro-lens array HOE, which presents double-sided 3D display feature.

  20. 3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition

    PubMed Central

    Holmes, James H.; O’Halloran, Rafael L.; Brodsky, Ethan K.; Jung, Youngkyoo; Block, Walter F.; Fain, Sean B.

    2010-01-01

    A method is presented for high resolution 3D imaging of the whole lung using inhaled hyperpolarized (HP) He-3 MR with multiple half-echo radial trajectories that can accelerate imaging through undersampling. A multiple half-echo radial trajectory can be used to reduce the level of artifact for undersampled 3D projection reconstruction (PR) imaging by increasing the amount of data acquired per unit time for HP He-3 lung imaging. The point spread functions (PSFs) for breath-held He-3 MRI using multiple half-echo trajectories were evaluated using simulations to predict the effects of T2* and gas diffusion on image quality. Results from PSF simulations were consistent with imaging results in volunteer studies showing improved image quality with increasing number of echoes using up to 8 half-echoes. The 8 half-echo acquisition is shown to accommodate lost breath-holds as short as 6 s using a retrospective reconstruction at reduced resolution as well as to allow reduced breath-hold time compared to an equivalent Cartesian trajectory. Furthermore, preliminary results from a 3D dynamic inhalation-exhalation maneuver are demonstrated using the 8 half-echo trajectory. Results demonstrate the first high resolution 3D PR imaging of ventilation and respiratory dynamics in humans using HP He-3 MR. PMID:18429034

  1. Audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI

    NASA Astrophysics Data System (ADS)

    Lee, D.; Greer, P. B.; Arm, J.; Keall, P.; Kim, T.

    2014-03-01

    The purpose of this study was to test the hypothesis that audiovisual (AV) biofeedback can improve image quality and reduce scan time for respiratory-gated 3D thoracic MRI. For five healthy human subjects respiratory motion guidance in MR scans was provided using an AV biofeedback system, utilizing real-time respiratory motion signals. To investigate the improvement of respiratory-gated 3D MR images between free breathing (FB) and AV biofeedback (AV), each subject underwent two imaging sessions. Respiratory-related motion artifacts and imaging time were qualitatively evaluated in addition to the reproducibility of external (abdominal) motion. In the results, 3D MR images in AV biofeedback showed more anatomic information such as a clear distinction of diaphragm, lung lobes and sharper organ boundaries. The scan time was reduced from 401±215 s in FB to 334±94 s in AV (p-value 0.36). The root mean square variation of the displacement and period of the abdominal motion was reduced from 0.4±0.22 cm and 2.8±2.5 s in FB to 0.1±0.15 cm and 0.9±1.3 s in AV (p-value of displacement <0.01 and p-value of period 0.12). This study demonstrated that audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI. These results suggest that AV biofeedback has the potential to be a useful motion management tool in medical imaging and radiation therapy procedures.

  2. Frames-Based Denoising in 3D Confocal Microscopy Imaging.

    PubMed

    Konstantinidis, Ioannis; Santamaria-Pang, Alberto; Kakadiaris, Ioannis

    2005-01-01

    In this paper, we propose a novel denoising method for 3D confocal microscopy data based on robust edge detection. Our approach relies on the construction of a non-separable frame system in 3D that incorporates the Sobel operator in dual spatial directions. This multidirectional set of digital filters is capable of robustly detecting edge information by ensemble thresholding of the filtered data. We demonstrate the application of our method to both synthetic and real confocal microscopy data by comparing it to denoising methods based on separable 3D wavelets and 3D median filtering, and report very encouraging results.

  3. Deformable templates guided discriminative models for robust 3D brain MRI segmentation.

    PubMed

    Liu, Cheng-Yi; Iglesias, Juan Eugenio; Tu, Zhuowen

    2013-10-01

    Automatically segmenting anatomical structures from 3D brain MRI images is an important task in neuroimaging. One major challenge is to design and learn effective image models accounting for the large variability in anatomy and data acquisition protocols. A deformable template is a type of generative model that attempts to explicitly match an input image with a template (atlas), and thus, they are robust against global intensity changes. On the other hand, discriminative models combine local image features to capture complex image patterns. In this paper, we propose a robust brain image segmentation algorithm that fuses together deformable templates and informative features. It takes advantage of the adaptation capability of the generative model and the classification power of the discriminative models. The proposed algorithm achieves both robustness and efficiency, and can be used to segment brain MRI images with large anatomical variations. We perform an extensive experimental study on four datasets of T1-weighted brain MRI data from different sources (1,082 MRI scans in total) and observe consistent improvement over the state-of-the-art systems.

  4. On-line 3D motion estimation using low resolution MRI

    NASA Astrophysics Data System (ADS)

    Glitzner, M.; de Senneville, B. Denis; Lagendijk, J. J. W.; Raaymakers, B. W.; Crijns, S. P. M.

    2015-08-01

    Image processing such as deformable image registration finds its way into radiotherapy as a means to track non-rigid anatomy. With the advent of magnetic resonance imaging (MRI) guided radiotherapy, intrafraction anatomy snapshots become technically feasible. MRI provides the needed tissue signal for high-fidelity image registration. However, acquisitions, especially in 3D, take a considerable amount of time. Pushing towards real-time adaptive radiotherapy, MRI needs to be accelerated without degrading the quality of information. In this paper, we investigate the impact of image resolution on the quality of motion estimations. Potentially, spatially undersampled images yield comparable motion estimations. At the same time, their acquisition times would reduce greatly due to the sparser sampling. In order to substantiate this hypothesis, exemplary 4D datasets of the abdomen were downsampled gradually. Subsequently, spatiotemporal deformations are extracted consistently using the same motion estimation for each downsampled dataset. Errors between the original and the respectively downsampled version of the dataset are then evaluated. Compared to ground-truth, results show high similarity of deformations estimated from downsampled image data. Using a dataset with {{≤ft(2.5 \\text{mm}\\right)}3} voxel size, deformation fields could be recovered well up to a downsampling factor of 2, i.e. {{≤ft(5 \\text{mm}\\right)}3} . In a therapy guidance scenario MRI, imaging speed could accordingly increase approximately fourfold, with acceptable loss of estimated motion quality.

  5. Plaque characterization in ex vivo MRI evaluated by dense 3D correspondence with histology

    NASA Astrophysics Data System (ADS)

    van Engelen, Arna; de Bruijne, Marleen; Klein, Stefan; Verhagen, Hence; Groen, Harald; Wentzel, Jolanda; van der Lugt, Aad; Niessen, Wiro

    2011-03-01

    Automatic quantification of carotid artery plaque composition is important in the development of methods that distinguish vulnerable from stable plaques. MRI has shown to be capable of imaging different components noninvasively. We present a new plaque classification method which uses 3D registration of histology data with ex vivo MRI data, using non-rigid registration, both for training and evaluation. This is more objective than previously presented methods, as it eliminates selection bias that is introduced when 2D MRI slices are manually matched to histological slices before evaluation. Histological slices of human atherosclerotic plaques were manually segmented into necrotic core, fibrous tissue and calcification. Classification of these three components was voxelwise evaluated. As features the intensity, gradient magnitude and Laplacian in four MRI sequences after different degrees of Gaussian smoothing, and the distances to the lumen and the outer vessel wall, were used. Performance of linear and quadratic discriminant classifiers for different combinations of features was evaluated. Best accuracy (72.5 +/- 7.7%) was reached with the linear classifier when all features were used. Although this was only a minor improvement to the accuracy of a classifier that only included the intensities and distance features (71.6 +/- 7.9%), the difference was statistically significant (paired t-test, p<0.05). Good sensitivity and specificity for calcification was reached (83% and 95% respectively), however, differentiation between fibrous (sensitivity 85%, specificity 60%) and necrotic tissue (sensitivity 49%, specificity 89%) was more difficult.

  6. [Detection of oculomotor nerve compression by 3D-FIESTA MRI in a patient with pituitary apoplexy and diabetes mellitus].

    PubMed

    Yamauchi, Takahiro; Kitai, Ryuhei; Neishi, Hiroyuki; Tsunetoshi, Kenzo; Matsuda, Ken; Arishima, Hidetaka; Kodera, Toshiaki; Arai, Yoshikazu; Takeuchi, Hiroaki; Kikuta, Ken-ichiro

    2014-02-01

    We report the usefulness of 3D-FIESTA magnetic resonance imaging(MRI)for the detection of oculomotor nerve palsy in a case of pituitary apoplexy. A 69-year-old man with diabetes mellitus presented with complete left-side blepharoptosis. Computed tomography of the brain showed an intrasellar mass with hemorrhage. MRI demonstrated a pituitary adenoma with a cyst toward the left cavernous sinus, which was diagnosed as pituitary apoplexy. 3D-FIESTA revealed that the left oculomotor nerve was compressed by the cyst. He underwent trans-sphenoid tumor resection at 5 days after his hospitalization. Post-operative 3D-FIESTA MRI revealed decrease in compression of the left oculomotor nerve by the cyst. His left oculomotor palsy recovered completely within a few months. Oculomotor nerve palsy can occur due to various diseases, and 3D-FIESTA MRI is useful for detection of oculomotor nerve compression, especially in the field of parasellar lesions.

  7. Hybrid atlas-based and image-based approach for segmenting 3D brain MRIs

    NASA Astrophysics Data System (ADS)

    Bueno, Gloria; Musse, Olivier; Heitz, Fabrice; Armspach, Jean-Paul

    2001-07-01

    This work is a contribution to the problem of localizing key cerebral structures in 3D MRIs and its quantitative evaluation. In pursuing it, the cooperation between an image-based segmentation method and a hierarchical deformable registration approach has been considered. The segmentation relies on two main processes: homotopy modification and contour decision. The first one is achieved by a marker extraction stage where homogeneous 3D regions of an image, I(s), from the data set are identified. These regions, M(I), are obtained combining information from deformable atlas, achieved by the warping of eight previous labeled maps on I(s). Then, the goal of the decision stage is to precisely locate the contours of the 3D regions set by the markers. This contour decision is performed by a 3D extension of the watershed transform. The anatomical structures taken into consideration and embedded into the atlas are brain, ventricles, corpus callosum, cerebellum, right and left hippocampus, medulla and midbrain. The hybrid method operates fully automatically and in 3D, successfully providing segmented brain structures. The quality of the segmentation has been studied in terms of the detected volume ratio by using kappa statistic and ROC analysis. Results of the method are shown and validated on a 3D MRI phantom. This study forms part of an on-going long term research aiming at the creation of a 3D probabilistic multi-purpose anatomical brain atlas.

  8. Review: Polymeric-Based 3D Printing for Tissue Engineering.

    PubMed

    Wu, Geng-Hsi; Hsu, Shan-Hui

    Three-dimensional (3D) printing, also referred to as additive manufacturing, is a technology that allows for customized fabrication through computer-aided design. 3D printing has many advantages in the fabrication of tissue engineering scaffolds, including fast fabrication, high precision, and customized production. Suitable scaffolds can be designed and custom-made based on medical images such as those obtained from computed tomography. Many 3D printing methods have been employed for tissue engineering. There are advantages and limitations for each method. Future areas of interest and progress are the development of new 3D printing platforms, scaffold design software, and materials for tissue engineering applications.

  9. Manifold learning for shape guided segmentation of cardiac boundaries: application to 3D+t cardiac MRI.

    PubMed

    Eslami, Abouzar; Yigitsoy, Mehmet; Navab, Nassir

    2011-01-01

    In this paper we propose a new method for shape guided segmentation of cardiac boundaries based on manifold learning of the shapes represented by the phase field approximation of the Mumford-Shah functional. A novel distance is defined to measure the similarity of shapes without requiring deformable registration. Cardiac motion is compensated and phases are mapped into one reference phase, that is the end of diastole, to avoid time warping and synchronization at all cardiac phases. Non-linear embedding of these 3D shapes extracts the manifold of the inter-subject variation of the heart shape to be used for guiding the segmentation for a new subject. For validation the method is applied to a comprehensive dataset of 3D+t cardiac Cine MRI from normal subjects and patients.

  10. Reconstruction of the human brain from MRI-T1 using 3-D morphology and snake

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Yang; Ching, Yu-Tai

    2002-04-01

    Accurate reconstruction of the human brain in MRI-T1 images is valuable and important to clinical needs. In this paper, the morphology and snake techniques are proposed to reconstruct a human brain model. First step in our method is to preprocess the volumetric image to remove skull, muscle, fat, and other non-brain tissue. We use a method of 3-d region growing. It has the advantage over thresholding that the resulting objects will be spatially connected, since brain has the connected property. Second, we use clustering method, and than use them to produce an initial estimate of the cortical surface. Third, we propose a novel active contour algorithm to move the snake toward the cortex. Thus we can use the snake to segment the brain. We use a wavelet method to model the external force that significantly increases the capture range of a traditional snake. Afterwards, we render the volumetric image to display the brain from multiple views. Both simulated data and patient data have been use to test the proposed techniques. The proposed method combines various techniques of 3-D morphology, clustering, active contour, wavelet, and volume rendering to accurately, robustly, and automatically reconstruct brain from MRI-T1 images.

  11. 3D Wavelet-Based Filter and Method

    DOEpatents

    Moss, William C.; Haase, Sebastian; Sedat, John W.

    2008-08-12

    A 3D wavelet-based filter for visualizing and locating structural features of a user-specified linear size in 2D or 3D image data. The only input parameter is a characteristic linear size of the feature of interest, and the filter output contains only those regions that are correlated with the characteristic size, thus denoising the image.

  12. Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements.

    PubMed

    van Pelt, Roy; Nguyen, Huy; ter Haar Romeny, Bart; Vilanova, Anna

    2012-03-01

    Quantitative analysis of vascular blood flow, acquired by phase-contrast MRI, requires accurate segmentation of the vessel lumen. In clinical practice, 2D-cine velocity-encoded slices are inspected, and the lumen is segmented manually. However, segmentation of time-resolved volumetric blood-flow measurements is a tedious and time-consuming task requiring automation. Automated segmentation of large thoracic arteries, based solely on the 3D-cine phase-contrast MRI (PC-MRI) blood-flow data, was done. An active surface model, which is fast and topologically stable, was used. The active surface model requires an initial surface, approximating the desired segmentation. A method to generate this surface was developed based on a voxel-wise temporal maximum of blood-flow velocities. The active surface model balances forces, based on the surface structure and image features derived from the blood-flow data. The segmentation results were validated using volunteer studies, including time-resolved 3D and 2D blood-flow data. The segmented surface was intersected with a velocity-encoded PC-MRI slice, resulting in a cross-sectional contour of the lumen. These cross-sections were compared to reference contours that were manually delineated on high-resolution 2D-cine slices. The automated approach closely approximates the manual blood-flow segmentations, with error distances on the order of the voxel size. The initial surface provides a close approximation of the desired luminal geometry. This improves the convergence time of the active surface and facilitates parametrization. An active surface approach for vessel lumen segmentation was developed, suitable for quantitative analysis of 3D-cine PC-MRI blood-flow data. As opposed to prior thresholding and level-set approaches, the active surface model is topologically stable. A method to generate an initial approximate surface was developed, and various features that influence the segmentation model were evaluated. The active surface

  13. Image based 3D city modeling : Comparative study

    NASA Astrophysics Data System (ADS)

    Singh, S. P.; Jain, K.; Mandla, V. R.

    2014-06-01

    3D city model is a digital representation of the Earth's surface and it's related objects such as building, tree, vegetation, and some manmade feature belonging to urban area. The demand of 3D city modeling is increasing rapidly for various engineering and non-engineering applications. Generally four main image based approaches were used for virtual 3D city models generation. In first approach, researchers were used Sketch based modeling, second method is Procedural grammar based modeling, third approach is Close range photogrammetry based modeling and fourth approach is mainly based on Computer Vision techniques. SketchUp, CityEngine, Photomodeler and Agisoft Photoscan are the main softwares to represent these approaches respectively. These softwares have different approaches & methods suitable for image based 3D city modeling. Literature study shows that till date, there is no complete such type of comparative study available to create complete 3D city model by using images. This paper gives a comparative assessment of these four image based 3D modeling approaches. This comparative study is mainly based on data acquisition methods, data processing techniques and output 3D model products. For this research work, study area is the campus of civil engineering department, Indian Institute of Technology, Roorkee (India). This 3D campus acts as a prototype for city. This study also explains various governing parameters, factors and work experiences. This research work also gives a brief introduction, strengths and weakness of these four image based techniques. Some personal comment is also given as what can do or what can't do from these softwares. At the last, this study shows; it concluded that, each and every software has some advantages and limitations. Choice of software depends on user requirements of 3D project. For normal visualization project, SketchUp software is a good option. For 3D documentation record, Photomodeler gives good result. For Large city

  14. Quantification of Diaphragm Mechanics in Pompe Disease Using Dynamic 3D MRI

    PubMed Central

    Mogalle, Katja; Perez-Rovira, Adria; Ciet, Pierluigi; Wens, Stephan C. A.; van Doorn, Pieter A.; Tiddens, Harm A. W. M.; van der Ploeg, Ans T.; de Bruijne, Marleen

    2016-01-01

    Background Diaphragm weakness is the main reason for respiratory dysfunction in patients with Pompe disease, a progressive metabolic myopathy affecting respiratory and limb-girdle muscles. Since respiratory failure is the major cause of death among adult patients, early identification of respiratory muscle involvement is necessary to initiate treatment in time and possibly prevent irreversible damage. In this paper we investigate the suitability of dynamic MR imaging in combination with state-of-the-art image analysis methods to assess respiratory muscle weakness. Methods The proposed methodology relies on image registration and lung surface extraction to quantify lung kinematics during breathing. This allows for the extraction of geometry and motion features of the lung that characterize the independent contribution of the diaphragm and the thoracic muscles to the respiratory cycle. Results Results in 16 3D+t MRI scans (10 Pompe patients and 6 controls) of a slow expiratory maneuver show that kinematic analysis from dynamic 3D images reveals important additional information about diaphragm mechanics and respiratory muscle involvement when compared to conventional pulmonary function tests. Pompe patients with severely reduced pulmonary function showed severe diaphragm weakness presented by minimal motion of the diaphragm. In patients with moderately reduced pulmonary function, cranial displacement of posterior diaphragm parts was reduced and the diaphragm dome was oriented more horizontally at full inspiration compared to healthy controls. Conclusion Dynamic 3D MRI provides data for analyzing the contribution of both diaphragm and thoracic muscles independently. The proposed image analysis method has the potential to detect less severe diaphragm weakness and could thus be used to determine the optimal start of treatment in adult patients with Pompe disease in prospect of increased treatment response. PMID:27391236

  15. Quantification of Diaphragm Mechanics in Pompe Disease Using Dynamic 3D MRI.

    PubMed

    Mogalle, Katja; Perez-Rovira, Adria; Ciet, Pierluigi; Wens, Stephan C A; van Doorn, Pieter A; Tiddens, Harm A W M; van der Ploeg, Ans T; de Bruijne, Marleen

    2016-01-01

    Diaphragm weakness is the main reason for respiratory dysfunction in patients with Pompe disease, a progressive metabolic myopathy affecting respiratory and limb-girdle muscles. Since respiratory failure is the major cause of death among adult patients, early identification of respiratory muscle involvement is necessary to initiate treatment in time and possibly prevent irreversible damage. In this paper we investigate the suitability of dynamic MR imaging in combination with state-of-the-art image analysis methods to assess respiratory muscle weakness. The proposed methodology relies on image registration and lung surface extraction to quantify lung kinematics during breathing. This allows for the extraction of geometry and motion features of the lung that characterize the independent contribution of the diaphragm and the thoracic muscles to the respiratory cycle. Results in 16 3D+t MRI scans (10 Pompe patients and 6 controls) of a slow expiratory maneuver show that kinematic analysis from dynamic 3D images reveals important additional information about diaphragm mechanics and respiratory muscle involvement when compared to conventional pulmonary function tests. Pompe patients with severely reduced pulmonary function showed severe diaphragm weakness presented by minimal motion of the diaphragm. In patients with moderately reduced pulmonary function, cranial displacement of posterior diaphragm parts was reduced and the diaphragm dome was oriented more horizontally at full inspiration compared to healthy controls. Dynamic 3D MRI provides data for analyzing the contribution of both diaphragm and thoracic muscles independently. The proposed image analysis method has the potential to detect less severe diaphragm weakness and could thus be used to determine the optimal start of treatment in adult patients with Pompe disease in prospect of increased treatment response.

  16. NoSQL Based 3D City Model Management System

    NASA Astrophysics Data System (ADS)

    Mao, B.; Harrie, L.; Cao, J.; Wu, Z.; Shen, J.

    2014-04-01

    To manage increasingly complicated 3D city models, a framework based on NoSQL database is proposed in this paper. The framework supports import and export of 3D city model according to international standards such as CityGML, KML/COLLADA and X3D. We also suggest and implement 3D model analysis and visualization in the framework. For city model analysis, 3D geometry data and semantic information (such as name, height, area, price and so on) are stored and processed separately. We use a Map-Reduce method to deal with the 3D geometry data since it is more complex, while the semantic analysis is mainly based on database query operation. For visualization, a multiple 3D city representation structure CityTree is implemented within the framework to support dynamic LODs based on user viewpoint. Also, the proposed framework is easily extensible and supports geoindexes to speed up the querying. Our experimental results show that the proposed 3D city management system can efficiently fulfil the analysis and visualization requirements.

  17. 3D cardiac motion reconstruction from CT data and tagged MRI.

    PubMed

    Wang, Xiaoxu; Mihalef, Viorel; Qian, Zhen; Voros, Szilard; Metaxas, Dimitris

    2012-01-01

    In this paper we present a novel method for left ventricle (LV) endocardium motion reconstruction using high resolution CT data and tagged MRI. High resolution CT data provide anatomic details on the LV endocardial surface, such as the papillary muscle and trabeculae carneae. Tagged MRI provides better time resolution. The combination of these two imaging techniques can give us better understanding on left ventricle motion. The high resolution CT images are segmented with mean shift method and generate the LV endocardium mesh. The meshless deformable model built with high resolution endocardium surface from CT data fit to the tagged MRI of the same phase. 3D deformation of the myocardium is computed with the Lagrangian dynamics and local Laplacian deformation. The segmented inner surface of left ventricle is compared with the heart inner surface picture and show high agreement. The papillary muscles are attached to the inner surface with roots. The free wall of the left ventricle inner surface is covered with trabeculae carneae. The deformation of the heart wall and the papillary muscle in the first half of the cardiac cycle is presented. The motion reconstruction results are very close to the live heart video.

  18. EEG-MRI co-registration and sensor labeling using a 3D laser scanner.

    PubMed

    Koessler, L; Cecchin, T; Caspary, O; Benhadid, A; Vespignani, H; Maillard, L

    2011-03-01

    This paper deals with the co-registration of an MRI scan with EEG sensors. We set out to evaluate the effectiveness of a 3D handheld laser scanner, a device that is not widely used for co-registration, applying a semi-automatic procedure that also labels EEG sensors. The scanner acquired the sensors' positions and the face shape, and the scalp mesh was obtained from the MRI scan. A pre-alignment step, using the position of three fiducial landmarks, provided an initial value for co-registration, and the sensors were automatically labeled. Co-registration was then performed using an iterative closest point algorithm applied to the face shape. The procedure was conducted on five subjects with two scans of EEG sensors and one MRI scan each. The mean time for the digitization of the 64 sensors and three landmarks was 53 s. The average scanning time for the face shape was 2 min 6 s for an average number of 5,263 points. The mean residual error of the sensors co-registration was 2.11 mm. These results suggest that the laser scanner associated with an efficient co-registration and sensor labeling algorithm is sufficiently accurate, fast and user-friendly for longitudinal and retrospective brain sources imaging studies.

  19. Surgeon-Based 3D Printing for Microvascular Bone Flaps.

    PubMed

    Taylor, Erin M; Iorio, Matthew L

    2017-03-04

    Background Three-dimensional (3D) printing has developed as a revolutionary technology with the capacity to design accurate physical models in preoperative planning. We present our experience in surgeon-based design of 3D models, using home 3D software and printing technology for use as an adjunct in vascularized bone transfer. Methods Home 3D printing techniques were used in the design and execution of vascularized bone flap transfers to the upper extremity. Open source imaging software was used to convert preoperative computed tomography scans and create 3D models. These were printed in the surgeon's office as 3D models for the planned reconstruction. Vascularized bone flaps were designed intraoperatively based on the 3D printed models. Results Three-dimensional models were created for intraoperative use in vascularized bone flaps, including (1) medial femoral trochlea (MFT) flap for scaphoid avascular necrosis and nonunion, (2) MFT flap for lunate avascular necrosis and nonunion, (3) medial femoral condyle (MFC) flap for wrist arthrodesis, and (4) free fibula osteocutaneous flap for distal radius septic nonunion. Templates based on the 3D models allowed for the precise and rapid contouring of well-vascularized bone flaps in situ, prior to ligating the donor pedicle. Conclusions Surgeon-based 3D printing is a feasible, innovative technology that allows for the precise and rapid contouring of models that can be created in various configurations for pre- and intraoperative planning. The technology is easy to use, convenient, and highly economical as compared with traditional send-out manufacturing. Surgeon-based 3D printing is a useful adjunct in vascularized bone transfer. Level of Evidence Level IV.

  20. Reconstruction-based 3D/2D image registration.

    PubMed

    Tomazevic, Dejan; Likar, Bostjan; Pernus, Franjo

    2005-01-01

    In this paper we present a novel 3D/2D registration method, where first, a 3D image is reconstructed from a few 2D X-ray images and next, the preoperative 3D image is brought into the best possible spatial correspondence with the reconstructed image by optimizing a similarity measure. Because the quality of the reconstructed image is generally low, we introduce a novel asymmetric mutual information similarity measure, which is able to cope with low image quality as well as with different imaging modalities. The novel 3D/2D registration method has been evaluated using standardized evaluation methodology and publicly available 3D CT, 3DRX, and MR and 2D X-ray images of two spine phantoms, for which gold standard registrations were known. In terms of robustness, reliability and capture range the proposed method outperformed the gradient-based method and the method based on digitally reconstructed radiographs (DRRs).

  1. 3D Printing of Carbon Nanotubes-Based Microsupercapacitors.

    PubMed

    Yu, Wei; Zhou, Han; Li, Ben Q; Ding, Shujiang

    2017-02-08

    A novel 3D printing procedure is presented for fabricating carbon-nanotubes (CNTs)-based microsupercapacitors. The 3D printer uses a CNTs ink slurry with a moderate solid content and prints a stream of continuous droplets. Appropriate control of a heated base is applied to facilitate the solvent removal and adhesion between printed layers and to improve the structure integrity without structure delamination or distortion upon drying. The 3D-printed electrodes for microsupercapacitors are characterized by SEM, laser scanning confocal microscope, and step profiler. Effect of process parameters on 3D printing is also studied. The final solid-state microsupercapacitors are assembled with the printed multilayer CNTs structures and poly(vinyl alcohol)-H3PO4 gel as the interdigitated microelectrodes and electrolyte. The electrochemical performance of 3D printed microsupercapacitors is also tested, showing a significant areal capacitance and excellent cycle stability.

  2. 3D face recognition by projection-based methods

    NASA Astrophysics Data System (ADS)

    Dutagaci, Helin; Sankur, Bülent; Yemez, Yücel

    2006-02-01

    In this paper, we investigate recognition performances of various projection-based features applied on registered 3D scans of faces. Some features are data driven, such as ICA-based features or NNMF-based features. Other features are obtained using DFT or DCT-based schemes. We apply the feature extraction techniques to three different representations of registered faces, namely, 3D point clouds, 2D depth images and 3D voxel. We consider both global and local features. Global features are extracted from the whole face data, whereas local features are computed over the blocks partitioned from 2D depth images. The block-based local features are fused both at feature level and at decision level. The resulting feature vectors are matched using Linear Discriminant Analysis. Experiments using different combinations of representation types and feature vectors are conducted on the 3D-RMA dataset.

  3. An artificial immune-activated neural network applied to brain 3D MRI segmentation.

    PubMed

    Younis, Akmal; Ibrahim, Mohamed; Kabuka, Mansur; John, Nigel

    2008-10-01

    In this paper, a new neural network model inspired by the biological immune system functions is presented. The model, termed Artificial Immune-Activated Neural Network (AIANN), extracts classification knowledge from a training data set, which is then used to classify input patterns or vectors. The AIANN is based on a neuron activation function whose behavior is conceptually modeled after the chemical bonds between the receptors and epitopes in the biological immune system. The bonding is controlled through an energy measure to ensure accurate recognition. The AIANN model was applied to the segmentation of 3-dimensional magnetic resonance imaging (MRI) data of the brain and a contextual basis was developed for the segmentation problem. Evaluation of the segmentation results was performed using both real MRI data obtained from the Center for Morphometric Analysis at Massachusetts General Hospital and simulated MRI data generated using the McGill University BrainWeb MRI simulator. Experimental results demonstrated that the AIANN model attained higher average results than those obtained using published methods for real MRI data and simulated MRI data, especially at low levels of noise.

  4. 3D Printed Graphene Based Energy Storage Devices

    PubMed Central

    Foster, Christopher W.; Down, Michael P.; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J.; Smith, Graham C.; Kelly, Peter J.; Banks, Craig E.

    2017-01-01

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices’ to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (−0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (−0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised. PMID:28256602

  5. 3D Printed Graphene Based Energy Storage Devices.

    PubMed

    Foster, Christopher W; Down, Michael P; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J; Smith, Graham C; Kelly, Peter J; Banks, Craig E

    2017-03-03

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices' to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (-0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (-0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

  6. 3D Printed Graphene Based Energy Storage Devices

    NASA Astrophysics Data System (ADS)

    Foster, Christopher W.; Down, Michael P.; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J.; Smith, Graham C.; Kelly, Peter J.; Banks, Craig E.

    2017-03-01

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices’ to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (‑0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (‑0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

  7. Correlating 2D histological slice with 3D MRI image volume using smart phone as an interactive tool for muscle study.

    PubMed

    Eresen, Aydin; Li, Peng; Ji, Jim Xiuquan

    2014-01-01

    In muscle dystrophy studies, registration of histological image with MRI image volume enables cross validation of MRI biomarkers using pathological result. However, correlation of 2D histology slice with 3D MRI volume is technically challenging due to the potentially non-orthogonal slice plane and incomplete or distorted histological slice. This paper presents an efficient method to directly perform the 2D-3D registration. The method is unique in that it uses smart phone as a navigation tool for initial alignment followed by an overlap invariant mutual information-based refinement. Experimental results using animal muscle samples images from a 3T MRI and HE stained histological images show that the proposed method is capable of aligning the histological slice with an oblique slice in MR volume.

  8. 3D object recognition based on local descriptors

    NASA Astrophysics Data System (ADS)

    Jakab, Marek; Benesova, Wanda; Racev, Marek

    2015-01-01

    In this paper, we propose an enhanced method of 3D object description and recognition based on local descriptors using RGB image and depth information (D) acquired by Kinect sensor. Our main contribution is focused on an extension of the SIFT feature vector by the 3D information derived from the depth map (SIFT-D). We also propose a novel local depth descriptor (DD) that includes a 3D description of the key point neighborhood. Thus defined the 3D descriptor can then enter the decision-making process. Two different approaches have been proposed, tested and evaluated in this paper. First approach deals with the object recognition system using the original SIFT descriptor in combination with our novel proposed 3D descriptor, where the proposed 3D descriptor is responsible for the pre-selection of the objects. Second approach demonstrates the object recognition using an extension of the SIFT feature vector by the local depth description. In this paper, we present the results of two experiments for the evaluation of the proposed depth descriptors. The results show an improvement in accuracy of the recognition system that includes the 3D local description compared with the same system without the 3D local description. Our experimental system of object recognition is working near real-time.

  9. 3D MRI-Controlled Transurethral Ultrasound Prostate Therapy: Experimental Validation of Numerical Simulations

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; N'Djin, William Apoutou; Kobelevskiy, Ilya; Bronskill, Michael; Chopra, Rajiv

    2011-09-01

    MRI-guided transurethral ultrasound therapy uses a linear array of transducer elements and active temperature feedback to create volumes of thermal coagulation shaped to predefined prostate geometries in 3-D. Numerical simulations have been used to determine robust feedback control algorithms, optimal transducer designs, effects of various tissue and imaging parameters, as well as to evaluate potential treatment accuracy and safety in patient-specific anatomical models. The goal of this work is to evaluate quantitatively the accuracy with which these numerical simulations predict the extent, shape and temperature pattern of 3-D heating produced in tissue-mimicking Zerdine* gel phantoms. Methods. Eleven experiments were performed in a 1.5T MRI scanner. Temperature feedback was used to control the rotation rate and ultrasound power of a transurethral device with five 3.5×5 mm transducer elements. Heating patterns shaped to 23 and 11 cc human prostate geometries were generated using devices operating at 4.7 and 8.0 MHz, respectively, and 10 W/cm2 surface acoustic intensity. Transducer surface velocity measurements were acquired using a vibrometer and used to calculate the resulting acoustic pressure distribution in gel. Temperature dynamics were determined according to a FDTD solution to Pennes' BHTE. Results. The numerical simulations predicted the extent and shape of the coagulation boundary produced in gel to within (mean±stdev [min, max]): 0.1±0.4 [-1.4, 1.7] and 0.0±0.3 [-1.0, 1.5] mm for the treatments at 4.7 and 8.0 MHz, respectively. The temperatures across all MRI thermometry images were predicted to within 10%, and the treatment time (˜20 min) to within 20%. The simulations showed excellent agreement in regions of sharp temperature gradients, near the transurethral and endorectal devices. Conclusion. Heating patterns predicted by the numerical simulations correspond closely to those produced experimentally in gel. This work quantifies the accuracy and

  10. 3D curve inference for diffusion MRI regularization and fibre tractography.

    PubMed

    Savadjiev, Peter; Campbell, Jennifer S W; Pike, G Bruce; Siddiqi, Kaleem

    2006-10-01

    We develop a differential geometric framework for regularizing diffusion MRI data. The key idea is to model white matter fibres as 3D space curves and to then extend Parent and Zucker's 2D curve inference approach [Parent, P., Zucker, S., 1989. Trace inference, curvature consistency, and curve detection. IEEE Transactions on Pattern Analysis and Machine Intelligence 11, 823-839] by using a notion of co-helicity to indicate compatibility between fibre orientations at each voxel with those in a local neighborhood. We argue that this provides several advantages over earlier regularization methods. We validate the approach quantitatively on a biological phantom and on synthetic data, and qualitatively on data acquired in vivo from a human brain. We also demonstrate the use of the technique to improve the performance of a fibre tracking algorithm.

  11. Three-dimensional quantification of vorticity and helicity from 3D cine PC-MRI using finite-element interpolations.

    PubMed

    Sotelo, Julio; Urbina, Jesús; Valverde, Israel; Mura, Joaquín; Tejos, Cristián; Irarrazaval, Pablo; Andia, Marcelo E; Hurtado, Daniel E; Uribe, Sergio

    2017-03-31

    We propose a 3D finite-element method for the quantification of vorticity and helicity density from 3D cine phase-contrast (PC) MRI. By using a 3D finite-element method, we seamlessly estimate velocity gradients in 3D. The robustness and convergence were analyzed using a combined Poiseuille and Lamb-Ossen equation. A computational fluid dynamics simulation was used to compared our method with others available in the literature. Additionally, we computed 3D maps for different 3D cine PC-MRI data sets: phantom without and with coarctation (18 healthy volunteers and 3 patients). We found a good agreement between our method and both the analytical solution of the combined Poiseuille and Lamb-Ossen. The computational fluid dynamics results showed that our method outperforms current approaches to estimate vorticity and helicity values. In the in silico model, we observed that for a tetrahedral element of 2 mm of characteristic length, we underestimated the vorticity in less than 5% with respect to the analytical solution. In patients, we found higher values of helicity density in comparison to healthy volunteers, associated with vortices in the lumen of the vessels. We proposed a novel method that provides entire 3D vorticity and helicity density maps, avoiding the used of reformatted 2D planes from 3D cine PC-MRI. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Thermal analysis of the surrounding anatomy during 3-D MRI-guided transurethral ultrasound prostate therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2010-03-01

    Previous numerical simulations have shown that MRI-guided transurethral ultrasound therapy can generate highly accurate volumes of thermal coagulation conforming to 3-D human prostate geometries. The goal of this work is to simulate, quantify and evaluate the thermal impact of these treatments on the rectum, pelvic bone, neurovascular bundles (NVB) and urinary sphincters. This study used twenty 3-D anatomical models of prostate cancer patients and detailed bio-acoustic simulations incorporating an active feedback algorithm which controlled a rotating, planar ultrasound transducer (17-4×3 mm elements, 4.7/9.7 MHz, 10 Wac/cm2). Heating of the adjacent surrounding anatomy was evaluated using thermal tolerances reported in the literature. Heating of the rectum poses the most important safety concern and is influenced largely by the water temperature flowing through an endorectal cooling device; temperatures of 7-37° C are required to limit potential damage to less than 10 mm3 on the outer 1 mm layer of rectum. Significant heating of the pelvic bone was predicted in 30% of the patient models with an ultrasound frequency of 4.7 MHz; setting the frequency to 9.7 MHz when the bone is less than 10 mm away from the prostate reduced heating in all cases below the threshold for irreversible damage. Heating of the NVB was significant in 75% of the patient models in the absence of treatment planning; this proportion was reduced to 5% by using treatment margins of up to 4 mm. To avoid damaging the urinary sphincters, margins from the transducer of 2-4 mm should be used, depending on the transurethral cooling temperature. Simulations show that MRI-guided transurethral therapy can treat the entire prostate accurately. Strategies have been developed which, along with careful treatment planning, can be used to avoid causing thermal injury to the rectum, pelvic bone, NVB and urinary sphincters.

  13. Powder-based 3D printing for bone tissue engineering.

    PubMed

    Brunello, G; Sivolella, S; Meneghello, R; Ferroni, L; Gardin, C; Piattelli, A; Zavan, B; Bressan, E

    2016-01-01

    Bone tissue engineered 3-D constructs customized to patient-specific needs are emerging as attractive biomimetic scaffolds to enhance bone cell and tissue growth and differentiation. The article outlines the features of the most common additive manufacturing technologies (3D printing, stereolithography, fused deposition modeling, and selective laser sintering) used to fabricate bone tissue engineering scaffolds. It concentrates, in particular, on the current state of knowledge concerning powder-based 3D printing, including a description of the properties of powders and binder solutions, the critical phases of scaffold manufacturing, and its applications in bone tissue engineering. Clinical aspects and future applications are also discussed.

  14. Monocular panoramic 3D reconstruction based on a particle filter

    NASA Astrophysics Data System (ADS)

    Pagel, Frank

    2010-04-01

    This paper adresses the issue of generating a panoramic view and a panoramic depth maps using only a single camera. The proposed approach first estimates the egomotion of the camera. Based on this information, a particle filter approximates the 3D structure of the scene. Hence, 3D scene points are modeled probabilistically. These points are accumulated in a cylindric coordinate system. The probabilistic representation of 3D points is used to handle the problem of visualizing occluding and occluded scene points in a noisy environment to get a stable data visualization. This approach can be easily extended to calibrated multi-camera applications (even with non-overlapping field of views).

  15. Fast imaging of laboratory core floods using 3D compressed sensing RARE MRI.

    PubMed

    Ramskill, N P; Bush, I; Sederman, A J; Mantle, M D; Benning, M; Anger, B C; Appel, M; Gladden, L F

    2016-09-01

    Three-dimensional (3D) imaging of the fluid distributions within the rock is essential to enable the unambiguous interpretation of core flooding data. Magnetic resonance imaging (MRI) has been widely used to image fluid saturation in rock cores; however, conventional acquisition strategies are typically too slow to capture the dynamic nature of the displacement processes that are of interest. Using Compressed Sensing (CS), it is possible to reconstruct a near-perfect image from significantly fewer measurements than was previously thought necessary, and this can result in a significant reduction in the image acquisition times. In the present study, a method using the Rapid Acquisition with Relaxation Enhancement (RARE) pulse sequence with CS to provide 3D images of the fluid saturation in rock core samples during laboratory core floods is demonstrated. An objective method using image quality metrics for the determination of the most suitable regularisation functional to be used in the CS reconstructions is reported. It is shown that for the present application, Total Variation outperforms the Haar and Daubechies3 wavelet families in terms of the agreement of their respective CS reconstructions with a fully-sampled reference image. Using the CS-RARE approach, 3D images of the fluid saturation in the rock core have been acquired in 16min. The CS-RARE technique has been applied to image the residual water saturation in the rock during a water-water displacement core flood. With a flow rate corresponding to an interstitial velocity of vi=1.89±0.03ftday(-1), 0.1 pore volumes were injected over the course of each image acquisition, a four-fold reduction when compared to a fully-sampled RARE acquisition. Finally, the 3D CS-RARE technique has been used to image the drainage of dodecane into the water-saturated rock in which the dynamics of the coalescence of discrete clusters of the non-wetting phase are clearly observed. The enhancement in the temporal resolution that has

  16. A new strategy for respiration compensation, applied toward 3D free-breathing cardiac MRI.

    PubMed

    Madore, Bruno; Farnebäck, Gunnar; Westin, Carl-Fredrik; Durán-Mendicuti, Alejandra

    2006-07-01

    In thorax and abdomen imaging, image quality may be affected by breathing motion. Cardiac MR images are typically obtained while the patient holds his or her breath, to avoid respiration-related artifacts. Although useful, breath-holding imposes constraints on scan duration, which in turn limits the achievable resolution and SNR. Longer scan times would be required to improve image quality, and effective strategies are needed to compensate for respiratory motion. A novel approach at respiratory compensation, targeted toward 3D free-breathing cardiac MRI, is presented here. The method aims at suppressing the negative effects of respiratory-induced cardiac motion while capturing the heart's beating motion. The method is designed so that the acquired data can be reconstructed in two different ways: First, a time series of images is reconstructed to quantify and correct for respiratory motion. Then, the corrected data are reconstructed a final time into a cardiac-phase series of images to capture the heart's beating motion. The method was implemented, and initial results are presented. A cardiac-phase series of 3D images, covering the entire heart, was obtained for two free-breathing volunteers. The present method may prove especially useful in situations where breath-holding is not an option, for example, for very sick, mentally impaired or infant patients.

  17. Iterative 3D projection reconstruction of (23) Na data with an (1) H MRI constraint.

    PubMed

    Gnahm, Christine; Bock, Michael; Bachert, Peter; Semmler, Wolfhard; Behl, Nicolas G R; Nagel, Armin M

    2014-05-01

    To increase the signal-to-noise ratio (SNR) and to reduce artifacts in non-proton magnetic resonance imaging (MRI) by incorporation of a priori information from (1) H MR data in an iterative reconstruction. An iterative reconstruction algorithm for 3D projection reconstruction (3DPR) is presented that combines prior anatomical knowledge and image sparsity under a total variation (TV) constraint. A binary mask (BM) is used as an anatomical constraint to penalize non-zero signal intensities outside the object. The BM&TV method is evaluated in simulations and in MR measurements in volunteers. In simulated BM&TV brain data, the artifact level was reduced by 20% while structures were well preserved compared to gridding. SNR maps showed a spatially dependent SNR gain over gridding reconstruction, which was up to 100% for simulated data. Undersampled 3DPR (23) Na MRI of the human brain revealed an SNR increase of 29 ± 7%. Small anatomical structures were reproduced with a mean contrast loss of 14%, whereas in TV-regularized iterative reconstructions a loss of 66% was found. The BM&TV algorithm allows reconstructing images with increased SNR and reduced artifact level compared to gridding and performs superior to an iterative reconstruction using an unspecific TV constraint only. Copyright © 2013 Wiley Periodicals, Inc.

  18. Visual Semantic Based 3D Video Retrieval System Using HDFS

    PubMed Central

    Kumar, C.Ranjith; Suguna, S.

    2016-01-01

    This paper brings out a neoteric frame of reference for visual semantic based 3d video search and retrieval applications. Newfangled 3D retrieval application spotlight on shape analysis like object matching, classification and retrieval not only sticking up entirely with video retrieval. In this ambit, we delve into 3D-CBVR (Content Based Video Retrieval) concept for the first time. For this purpose, we intent to hitch on BOVW and Mapreduce in 3D framework. Instead of conventional shape based local descriptors, we tried to coalesce shape, color and texture for feature extraction. For this purpose, we have used combination of geometric & topological features for shape and 3D co-occurrence matrix for color and texture. After thriving extraction of local descriptors, TB-PCT (Threshold Based- Predictive Clustering Tree) algorithm is used to generate visual codebook and histogram is produced. Further, matching is performed using soft weighting scheme with L2 distance function. As a final step, retrieved results are ranked according to the Index value and acknowledged to the user as a feedback .In order to handle prodigious amount of data and Efficacious retrieval, we have incorporated HDFS in our Intellection. Using 3D video dataset, we future the performance of our proposed system which can pan out that the proposed work gives meticulous result and also reduce the time intricacy. PMID:28003793

  19. Visual Semantic Based 3D Video Retrieval System Using HDFS.

    PubMed

    Kumar, C Ranjith; Suguna, S

    2016-08-01

    This paper brings out a neoteric frame of reference for visual semantic based 3d video search and retrieval applications. Newfangled 3D retrieval application spotlight on shape analysis like object matching, classification and retrieval not only sticking up entirely with video retrieval. In this ambit, we delve into 3D-CBVR (Content Based Video Retrieval) concept for the first time. For this purpose, we intent to hitch on BOVW and Mapreduce in 3D framework. Instead of conventional shape based local descriptors, we tried to coalesce shape, color and texture for feature extraction. For this purpose, we have used combination of geometric & topological features for shape and 3D co-occurrence matrix for color and texture. After thriving extraction of local descriptors, TB-PCT (Threshold Based- Predictive Clustering Tree) algorithm is used to generate visual codebook and histogram is produced. Further, matching is performed using soft weighting scheme with L2 distance function. As a final step, retrieved results are ranked according to the Index value and acknowledged to the user as a feedback .In order to handle prodigious amount of data and Efficacious retrieval, we have incorporated HDFS in our Intellection. Using 3D video dataset, we future the performance of our proposed system which can pan out that the proposed work gives meticulous result and also reduce the time intricacy.

  20. Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift

    NASA Astrophysics Data System (ADS)

    Gobbi, David G.; Comeau, Roch M.; Lee, Belinda K. H.; Peters, Terence M.

    2000-04-01

    The usefulness of stereotactic neurosurgery performed via a craniotomy is limited because the craniotomy leads to a brain tissue shift of 10 mm on average. We have recently completed an examination of 2D intra-operative ultrasound as a means of visualization and measurement of brain shift. A commercial 3D tracking system was used for real-time registration of the ultrasound video to pre-operative MR images, and annotation of the images was used to measure the shift. More than 15 surgical cases have been performed thus far with the 2D system. We are now undertaking phantom studies with tracked 3D ultrasound, and have developed sophisticated tools for real- time overlay of ultrasound and MRI volumes. These tools include a virtual-reality view of the ultrasound probe with live ultrasound video superimposed over a 3D -rendered MRI of the brain, as well as 3D ultrasound/MRI transparency overlay views. Algorithms to automatically extract landmarks from MRI and 3D ultrasound images are under development. We aim to use these landmarks to automatically generate nonlinear warp transformations to correct the pre-operative MRI as well as surgical target coordinates for brain shift. Portions of the C++ code developed for this project have been contributed to the open-source Visualization Toolkit (VTK).

  1. Growth trajectories of the human fetal brain tissues estimated from 3D reconstructed in utero MRI.

    PubMed

    Scott, Julia A; Habas, Piotr A; Kim, Kio; Rajagopalan, Vidya; Hamzelou, Kia S; Corbett-Detig, James M; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2011-08-01

    In the latter half of gestation (20-40 gestational weeks), human brain growth accelerates in conjunction with cortical folding and the deceleration of ventricular zone progenitor cell proliferation. These processes are reflected in changes in the volume of respective fetal tissue zones. Thus far, growth trajectories of the fetal tissue zones have been extracted primarily from 2D measurements on histological sections and magnetic resonance imaging (MRI). In this study, the volumes of major fetal zones-cortical plate (CP), subplate and intermediate zone (SP+IZ), germinal matrix (GMAT), deep gray nuclei (DG), and ventricles (VENT)--are calculated from automatic segmentation of motion-corrected, 3D reconstructed MRI. We analyzed 48 T2-weighted MRI scans from 39 normally developing fetuses in utero between 20.57 and 31.14 gestational weeks (GW). The supratentorial volume (STV) increased linearly at a rate of 15.22% per week. The SP+IZ (14.75% per week) and DG (15.56% per week) volumes increased at similar rates. The CP increased at a greater relative rate (18.00% per week), while the VENT (9.18% per week) changed more slowly. Therefore, CP increased as a fraction of STV and the VENT fraction declined. The total GMAT volume slightly increased then decreased after 25 GW. We did not detect volumetric sexual dimorphisms or total hemispheric volume asymmetries, which may emerge later in gestation. Further application of the automated fetal brain segmentation to later gestational ages will bridge the gap between volumetric studies of premature brain development and normal brain development in utero. Published by Elsevier Ltd.

  2. Growth trajectories of the human fetal brain tissues estimated from 3D reconstructed in utero MRI

    PubMed Central

    Scott, Julia A.; Habas, Piotr A.; Kim, Kio; Rajagopalan, Vidya; Hamzelou, Kia S.; Corbett-Detig, James M.; Barkovich, A. James; Glenn, Orit A.; Studholme, Colin

    2012-01-01

    In the latter half of gestation (20 to 40 gestational weeks), human brain growth accelerates in conjunction with cortical folding and the deceleration of ventricular zone progenitor cell proliferation. These processes are reflected in changes in the volume of respective fetal tissue zones. Thus far, growth trajectories of the fetal tissue zones have been extracted primarily from 2D measurements on histological sections and magnetic resonance imaging (MRI). In this study, the volumes of major fetal zones—cortical plate (CP), subplate and intermediate zone (SP+IZ), germinal matrix (GMAT), deep gray nuclei (DG), and ventricles (VENT)—are calculated from automatic segmentation of motion-corrected, 3D reconstructed MRI. We analyzed 48 T2-weighted MRI scans from 39 normally developing fetuses in utero between 20.57 and 31.14 gestational weeks (GW). The supratentorial volume (STV) increased linearly at a rate of 15.22% per week. The SP+IZ (14.75% per week) and DG (15.56% per week) volumes increased at similar rates. The CP increased at a greater relative rate (18.00% per week), while the VENT (9.18% per week) changed more slowly. Therefore, CP increased as a fraction of STV and the VENT fraction declined. The total GMAT volume slightly increased then decreased after 25 GW. We did not detect volumetric sexual dimorphisms or total hemispheric volume asymmetries, which may emerge later in gestation. Further application of the automated fetal brain segmentation to later gestational ages will bridge the gap between volumetric studies of premature brain development and normal brain development in utero. PMID:21530634

  3. Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI.

    PubMed

    Kjaergaard, Jesper; Petersen, Claus Leth; Kjaer, Andreas; Schaadt, Bente Krogsgaard; Oh, Jae K; Hassager, Christian

    2006-12-01

    Radionuclide techniques, and recently MRI, have been used for clinical evaluation of right ventricular (RV) volumes function (RVEF) and volumes; but with the introduction of 3D echocardiography, new echocardiographic possibilities for RV evaluation independent of geometrical assumptions have emerged. This study compared classic and new echocardiographic and radionuclide estimates, including gated blood pool single-photon emission computed tomography (SPECT) of RV size and function to RV volumes, and ejection fraction (RVEF) measured by magnetic resonance imaging (MRI). Thirty-four subjects with (a) prior inferior ST-elevation myocardial infarction (n=17), (b) a history of pulmonary embolism and persistent dyspnea (n=7) or (c) normal subjects (n=10) had 2D and 3D echocardiography, SPECT and MRI within 24h. End-diastolic volume and peak tricuspid regurgitation velocity were increased in patients with a history of pulmonary embolism compared to healthy subjects, 130+/-26 ml vs. 94+/-26 ml, P<0.05, and 3.3+/-1.1m/s vs. 2.3+/-0.3m/s, P<0.05, respectively, whereas no differences in RVEF were seen in the three groups. Echocardiographic as well as SPECT estimates of RV volume showed significant correlation to RV volumes by MRI. Tricuspid annular plane systolic excursion (TAPSE) had the better correlation to RVEF by MRI, r=0.48, P<0.01; whereas 3D echocardiography had a correlation of 0.42, P<0.05. Compared to MRI, 3D echocardiography underestimated RVEF by 5.9%, 95% limits of agreement 1.6-10.2%. 3D echocardiographic estimates of RV size and RVEF show only moderate correlation to MRI measures of these parameters, and simple 2D echocardiographic estimates of RV size and function show similar correlations. For routine clinical purposes the simple TAPSE may be preferred over 3D and SPECT techniques for RVEF estimation.

  4. Prospective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking.

    PubMed

    Todd, Nick; Josephs, Oliver; Callaghan, Martina F; Lutti, Antoine; Weiskopf, Nikolaus

    2015-06-01

    We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2 × 2 × 3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  5. 3D model retrieval method based on mesh segmentation

    NASA Astrophysics Data System (ADS)

    Gan, Yuanchao; Tang, Yan; Zhang, Qingchen

    2012-04-01

    In the process of feature description and extraction, current 3D model retrieval algorithms focus on the global features of 3D models but ignore the combination of global and local features of the model. For this reason, they show less effective performance to the models with similar global shape and different local shape. This paper proposes a novel algorithm for 3D model retrieval based on mesh segmentation. The key idea is to exact the structure feature and the local shape feature of 3D models, and then to compares the similarities of the two characteristics and the total similarity between the models. A system that realizes this approach was built and tested on a database of 200 objects and achieves expected results. The results show that the proposed algorithm improves the precision and the recall rate effectively.

  6. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media.

    PubMed

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B; Jansen, Sanaz A; Macleod, Kay; Conzen, Suzanne D; Karczmar, Gregory S

    2015-01-01

    The purpose of this study was to use high resolution three-dimensional (3D) magnetic resonance imaging (MRI) to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12-20 weeks (n=12), were used in this study. A 34G, 45° tip Hamilton needle with a 25μL Hamilton syringe was inserted into the tip of the nipple. Approximately 20-25μL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p<0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p<0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers.

  7. High resolution 3D MRI of mouse mammary glands with intra-ductal injection of contrast media

    PubMed Central

    Markiewicz, Erica; Fan, Xiaobing; Mustafi, Devkumar; Zamora, Marta; Roman, Brian B.; Jansen, Sanaz A.; Macleod, Kay; Conzen, Suzanne D.; Karczmar, Gregory S.

    2014-01-01

    The purpose of this study was to use high resolution 3D MRI to study mouse mammary gland ductal architecture based on intra-ductal injection of contrast agents. Female FVB/N mice age 12–20 weeks (n = 12), were used in this study. A 34G, 45° tip Hamilton needle with a 25uL Hamilton syringe was inserted into the tip of the nipple. Approximately 20–25uL of a Gadodiamide/Trypan blue/saline solution was injected slowly over one minute into the nipple and duct. To prevent washout of contrast media from ducts due to perfusion, and maximize the conspicuity of ducts on MRI, mice were sacrificed one minute after injection. High resolution 3D T1-weighted images were acquired on a 9.4T Bruker scanner after sacrifice to eliminate motion artifacts and reduce contrast media leakage from ducts. Trypan blue staining was well distributed throughout the ductal tree. MRI showed the mammary gland ductal structure clearly. In spoiled gradient echo T1-weighted images, the signal-to-noise ratio of regions identified as enhancing mammary ducts following contrast injection was significantly higher than that of muscle (p < 0.02) and significantly higher than that of contralateral mammary ducts that were not injected with contrast media (p < 0.0001). The methods described here could be adapted for injection of specialized contrast agents to measure metabolism or target receptors in normal ducts and ducts with in situ cancers. PMID:25179139

  8. BlochSolver: A GPU-optimized fast 3D MRI simulator for experimentally compatible pulse sequences.

    PubMed

    Kose, Ryoichi; Kose, Katsumi

    2017-08-01

    A magnetic resonance imaging (MRI) simulator, which reproduces MRI experiments using computers, has been developed using two graphic-processor-unit (GPU) boards (GTX 1080). The MRI simulator was developed to run according to pulse sequences used in experiments. Experiments and simulations were performed to demonstrate the usefulness of the MRI simulator for three types of pulse sequences, namely, three-dimensional (3D) gradient-echo, 3D radio-frequency spoiled gradient-echo, and gradient-echo multislice with practical matrix sizes. The results demonstrated that the calculation speed using two GPU boards was typically about 7 TFLOPS and about 14 times faster than the calculation speed using CPUs (two 18-core Xeons). We also found that MR images acquired by experiment could be reproduced using an appropriate number of subvoxels, and that 3D isotropic and two-dimensional multislice imaging experiments for practical matrix sizes could be simulated using the MRI simulator. Therefore, we concluded that such powerful MRI simulators are expected to become an indispensable tool for MRI research and development. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. BlochSolver: A GPU-optimized fast 3D MRI simulator for experimentally compatible pulse sequences

    NASA Astrophysics Data System (ADS)

    Kose, Ryoichi; Kose, Katsumi

    2017-08-01

    A magnetic resonance imaging (MRI) simulator, which reproduces MRI experiments using computers, has been developed using two graphic-processor-unit (GPU) boards (GTX 1080). The MRI simulator was developed to run according to pulse sequences used in experiments. Experiments and simulations were performed to demonstrate the usefulness of the MRI simulator for three types of pulse sequences, namely, three-dimensional (3D) gradient-echo, 3D radio-frequency spoiled gradient-echo, and gradient-echo multislice with practical matrix sizes. The results demonstrated that the calculation speed using two GPU boards was typically about 7 TFLOPS and about 14 times faster than the calculation speed using CPUs (two 18-core Xeons). We also found that MR images acquired by experiment could be reproduced using an appropriate number of subvoxels, and that 3D isotropic and two-dimensional multislice imaging experiments for practical matrix sizes could be simulated using the MRI simulator. Therefore, we concluded that such powerful MRI simulators are expected to become an indispensable tool for MRI research and development.

  10. Automated 3D MRI volumetry reveals regional atrophy differences in Rasmussen encephalitis.

    PubMed

    Wagner, Jan; Schoene-Bake, Jan-Christoph; Bien, Christian G; Urbach, Horst; Elger, Christian E; Weber, Bernd

    2012-04-01

    Rasmussen encephalitis is a chronic immune-mediated disease leading to unilateral atrophy on magnetic resonance imaging (MRI) and progressive neurologic deficits. Until now, quantitative parameters describing the course of the disease on MRI require manual intervention and are, therefore, time-consuming and observer-dependent. Furthermore, regional atrophy differences cannot be evaluated with the previously published methods. In this study we present a fully automated volumetric approach applied to serial MRI scans of 12 patients with Rasmussen encephalitis. We retrospectively analyzed 12 patients with Rasmussen encephalitis with a disease onset between 2001 and 2008. All patients underwent a total of 66 serial MRI scans including a three-dimensional T(1) data set. The volumetric analysis was based on standard procedures of the freely available software FMRIB Software Library (FSL) and required about 45 min per scan. Furthermore, planimetric analyses were performed on 51 scans as described previously. The relative and absolute volume loss of the affected hemisphere was significantly higher compared to the unaffected hemisphere. Referring to regional atrophy differences our results show that the frontal lobe and the insula were preferentially involved in the atrophic process. The degree of hemispheric, parietal, and occipital atrophy was negatively correlated with the age at disease onset, indicating a more aggressive and outspread disease in young children compared to adolescents. Volumetric hemispheric ratio and planimetric hemispheric ratio correlated significantly, but planimetric hemispheric ratio underestimated the real degree of hemiatrophy, especially in patients with predominant affections outside the frontoinsular region. The volumetric analysis presented here offers a precise assessment of the disease progression in Rasmussen encephalitis in an observer-independent and time-efficient manner and gives an interesting insight into the course of the disease

  11. 3D documentation and visualization of external injury findings by integration of simple photography in CT/MRI data sets (IprojeCT).

    PubMed

    Campana, Lorenzo; Breitbeck, Robert; Bauer-Kreuz, Regula; Buck, Ursula

    2016-05-01

    This study evaluated the feasibility of documenting patterned injury using three dimensions and true colour photography without complex 3D surface documentation methods. This method is based on a generated 3D surface model using radiologic slice images (CT) while the colour information is derived from photographs taken with commercially available cameras. The external patterned injuries were documented in 16 cases using digital photography as well as highly precise photogrammetry-supported 3D structured light scanning. The internal findings of these deceased were recorded using CT and MRI. For registration of the internal with the external data, two different types of radiographic markers were used and compared. The 3D surface model generated from CT slice images was linked with the photographs, and thereby digital true-colour 3D models of the patterned injuries could be created (Image projection onto CT/IprojeCT). In addition, these external models were merged with the models of the somatic interior. We demonstrated that 3D documentation and visualization of external injury findings by integration of digital photography in CT/MRI data sets is suitable for the 3D documentation of individual patterned injuries to a body. Nevertheless, this documentation method is not a substitution for photogrammetry and surface scanning, especially when the entire bodily surface is to be recorded in three dimensions including all external findings, and when precise data is required for comparing highly detailed injury features with the injury-inflicting tool.

  12. 3D microstructure modeling of compressed fiber-based materials

    NASA Astrophysics Data System (ADS)

    Gaiselmann, Gerd; Tötzke, Christian; Manke, Ingo; Lehnert, Werner; Schmidt, Volker

    2014-07-01

    A novel parametrized model that describes the 3D microstructure of compressed fiber-based materials is introduced. It allows to virtually generate the microstructure of realistically compressed gas-diffusion layers (GDL). Given the input of a 3D microstructure of some fiber-based material, the model compresses the system of fibers in a uniaxial direction for arbitrary compression rates. The basic idea is to translate the fibers in the direction of compression according to a vector field which depends on the rate of compression and on the locations of fibers within the material. In order to apply the model to experimental 3D image data of fiber-based materials given for several compression states, an optimal vector field is estimated by simulated annealing. The model is applied to 3D image data of non-woven GDL in PEMFC gained by synchrotron tomography for different compression rates. The compression model is validated by comparing structural characteristics computed for experimentally compressed and virtually compressed microstructures, where two kinds of compression - using a flat stamp and a stamp with a flow-field profile - are applied. For both stamps types, a good agreement is found. Furthermore, the compression model is combined with a stochastic 3D microstructure model for uncompressed fiber-based materials. This allows to efficiently generate compressed fiber-based microstructures in arbitrary volumes.

  13. 3D ear identification based on sparse representation.

    PubMed

    Zhang, Lin; Ding, Zhixuan; Li, Hongyu; Shen, Ying

    2014-01-01

    Biometrics based personal authentication is an effective way for automatically recognizing, with a high confidence, a person's identity. Recently, 3D ear shape has attracted tremendous interests in research field due to its richness of feature and ease of acquisition. However, the existing ICP (Iterative Closet Point)-based 3D ear matching methods prevalent in the literature are not quite efficient to cope with the one-to-many identification case. In this paper, we aim to fill this gap by proposing a novel effective fully automatic 3D ear identification system. We at first propose an accurate and efficient template-based ear detection method. By utilizing such a method, the extracted ear regions are represented in a common canonical coordinate system determined by the ear contour template, which facilitates much the following stages of feature extraction and classification. For each extracted 3D ear, a feature vector is generated as its representation by making use of a PCA-based local feature descriptor. At the stage of classification, we resort to the sparse representation based classification approach, which actually solves an l1-minimization problem. To the best of our knowledge, this is the first work introducing the sparse representation framework into the field of 3D ear identification. Extensive experiments conducted on a benchmark dataset corroborate the effectiveness and efficiency of the proposed approach. The associated Matlab source code and the evaluation results have been made publicly online available at http://sse.tongji.edu.cn/linzhang/ear/srcear/srcear.htm.

  14. MRI of the foetal brain using a rapid 3D steady-state sequence

    PubMed Central

    Jarvis, D; McQuillan, H; Williams, F; Paley, M; Armitage, P

    2013-01-01

    Objective: To evaluate the capacity of a rapid T2 weighted three-dimensional (3D) sequence to diagnose foetal brain abnormalities by comparing the results with current two-dimensional (2D) methods. We have also made assessments of the estimates of energy deposition using those methods. Methods: 50 pregnant females were included in this study under the guidance of the institutional review board. All their foetuses had suspected brain abnormalities on antenatal ultrasonography or were at increased risk of a brain malformation based on the results of an earlier pregnancy. All the foetuses had a routine MR protocol that includes three orthogonal plane single-shot fast-spin echoes and 2D steady-state sequences. In addition, a 3D rapid steady-state sequence of the foetal brain was performed (acquisition time approximately 40 s), and the standard and 3D sequences were reported independently and the results were compared. The specific absorption rate (SAR) predicted by the scanner was recorded in 12 cases in order to estimate the energy deposited by the three sequences. Results: The 3D rapid steady-state sequences produced diagnostic-quality images in 41/50 (82%) cases. All the failures were in second trimester foetuses (9/26—35% failure rate). There was a discrepancy between the standard report and findings using the 3D sequence in 2/41 of the foetuses with good-quality 3D imaging. The predicted SAR deposition of the 3D steady-state sequences was comparable with the single-shot fast-spin echo sequence. Conclusion: Our initial assessments of a 3D rapid steady-state sequence to image the foetus are encouraging in terms of diagnostic information and acceptable energy deposition values. The high failure rate in second trimester foetuses probably relates to the greater mobility of the smaller foetuses, and improvements in the 3D sequence are required in terms of reduced acquisition time and higher resolution. Advances in knowledge: We have shown that 3D T2 weighted images

  15. In vivo MRI-based 3D mechanical stress-strain profiles of carotid plaques with juxtaluminal plaque haemorrhage: an exploratory study for the mechanism of subsequent cerebrovascular events.

    PubMed

    Teng, Z; Sadat, U; Huang, Y; Young, V E; Graves, M J; Lu, J; Gillard, J H

    2011-10-01

    Atherosclerotic plaque features, such as fibrous cap erosion, ulceration and rupture and presence of haemorrhage in carotid plaque are two important characteristics associated with subsequent cerebrovascular events and juxtaluminal haemorrhage/thrombus (JLH/T) indicates these two high-risk characteristics. This study aims to investigate the association between JLH/T and subsequent events in patients suffering from transient ischaemic attack (TIA). Three-dimensional mechanical analysis was employed to represent the critical mechanical stress (P-CStress) and stretch (P-CStretch) within the plaque. Fifty TIA patients with mild-to-moderate carotid stenosis (30-69%) underwent high-resolution magnetic resonance imaging (MRI) within 72 h of the acute event and eight were excluded from the analysis due to various reasons. A total of 21 patients were found to have JLH/T in the carotid plaque and 21 did not (N-JLH/T). During a 2-year follow-up period, 11 (52.4%) patients in the JLH/T group experienced recurrent events and none in the N-JLH/T group. Three-dimensional plaque structure was reconstructed based on the in vivo MRI for the mechanical analysis. P-CStress of both groups was comparable (N-JLH/T: 174.45 ± 63.96 kPa vs. JLH/T: 212.60 ± 89.54 kPa; p = 0.120), but P-CStretch of JLH/T was significantly bigger than that of N-JLH/T (N-JLH/T: 1.21 ± 0.08 vs. JLH/T: 2.10 ± 0.53; p < 0.0001). Moreover, there were much bigger variations in stress and stretch of the JLH/T group during one cardiac cycle than in those of N-JLH/T group. In vivo MRI-depicted JLH/T might be a high risk factor initiating recurrent events, as big deformation appearing around the rupture site might prevent healing and tear the haemorrhage/thrombus away from the host structure and prompt further thrombo-embolic events. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  16. 3D display based on parallax barrier with multiview zones.

    PubMed

    Lv, Guo-Jiao; Wang, Qiong-Hua; Zhao, Wu-Xiang; Wang, Jun

    2014-03-01

    A 3D display based on a parallax barrier with multiview zones is proposed. This display consists of a 2D display panel and a parallax barrier. The basic element of the parallax barrier has three narrow slits. They can show three columns of subpixels on the 2D display panel and form 3D pixels. The parallax barrier can provide multiview zones. In these multiview zones, the proposed 3D display can use a small number of views to achieve a high density of views. Therefore, the distance between views is the same as the conventional ones with more views. Considering the proposed display has fewer views, which bring more 3D pixels in the 3D images, the resolution and brightness will be higher than the conventional ones. A 12-view prototype of the proposed 3D display is developed, and it provides the same density of views as a conventional one with 28 views. Experimental results show the proposed display has higher resolution and brightness than the conventional one. The cross talk is also limited at a low level.

  17. DCT and DST Based Image Compression for 3D Reconstruction

    NASA Astrophysics Data System (ADS)

    Siddeq, Mohammed M.; Rodrigues, Marcos A.

    2017-03-01

    This paper introduces a new method for 2D image compression whose quality is demonstrated through accurate 3D reconstruction using structured light techniques and 3D reconstruction from multiple viewpoints. The method is based on two discrete transforms: (1) A one-dimensional Discrete Cosine Transform (DCT) is applied to each row of the image. (2) The output from the previous step is transformed again by a one-dimensional Discrete Sine Transform (DST), which is applied to each column of data generating new sets of high-frequency components followed by quantization of the higher frequencies. The output is then divided into two parts where the low-frequency components are compressed by arithmetic coding and the high frequency ones by an efficient minimization encoding algorithm. At decompression stage, a binary search algorithm is used to recover the original high frequency components. The technique is demonstrated by compressing 2D images up to 99% compression ratio. The decompressed images, which include images with structured light patterns for 3D reconstruction and from multiple viewpoints, are of high perceptual quality yielding accurate 3D reconstruction. Perceptual assessment and objective quality of compression are compared with JPEG and JPEG2000 through 2D and 3D RMSE. Results show that the proposed compression method is superior to both JPEG and JPEG2000 concerning 3D reconstruction, and with equivalent perceptual quality to JPEG2000.

  18. Photograph-based 3D modeling in an educational system

    NASA Astrophysics Data System (ADS)

    Ohgashi, Hitoshi; Itoh, Yuki; Shibayama, Jun-Ichi

    1996-03-01

    In this paper, we describe a method of 3D modeling based on photographs for real-time graphics system of educational use. The method uses few basic models like squares, spheres and so on, and a 3D model is constructed by modifying basic models, guided by parameters. For example, we made an educational real-time graphics system of the deep space, having galaxies' 3D models. A typical galaxy called spiral galaxy consists of two parts; a spherical center part named bulge, and a whirlpool convex-lens shaped surrounding part named galactic disc. Galaxies' photographs are taken from a limited angle, because they are too far away, and viewed only from the earth. So a galaxies' photograph is whether in a whirlpool form, a convex-lens form, or in a slant form between the two forms. Therefore our method puts a sphere model at the bulge position, and a convex-lens model formed by a sphere metamorphism at the galactic disc position. Parameters are used to change galaxies' position, size, XYZ-axes metamorphism and rotation. Thus we get a 3D galaxy model corresponding to the photograph, and learners can look at a 3D galaxy from any viewpoint and view direction. In this way, we construct realistic 3D models. The amount of rendering computation is still low. Thus real-time rendering images are produced freely from a moving viewpoint and view direction.

  19. Fast globally optimal segmentation of 3D prostate MRI with axial symmetry prior.

    PubMed

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    We propose a novel global optimization approach to segmenting a given 3D prostate T2w magnetic resonance (MR) image, which enforces the inherent axial symmetry of the prostate shape and simultaneously performs a sequence of 2D axial slice-wise segmentations with a global 3D coherence prior. We show that the proposed challenging combinatorial optimization problem can be solved globally and exactly by means of convex relaxation. With this regard, we introduce a novel coupled continuous max-flow model, which is dual to the studied convex relaxed optimization formulation and leads to an efficient multiplier augmented algorithm based on the modern convex optimization theory. Moreover, the new continuous max-flow based algorithm was implemented on GPUs to achieve a substantial improvement in computation. Experimental results using public and in-house datasets demonstrate great advantages of the proposed method in terms of both accuracy and efficiency.

  20. 3D measurement system based on computer-generated gratings

    NASA Astrophysics Data System (ADS)

    Zhu, Yongjian; Pan, Weiqing; Luo, Yanliang

    2010-08-01

    A new kind of 3D measurement system has been developed to achieve the 3D profile of complex object. The principle of measurement system is based on the triangular measurement of digital fringe projection, and the fringes are fully generated from computer. Thus the computer-generated four fringes form the data source of phase-shifting 3D profilometry. The hardware of system includes the computer, video camera, projector, image grabber, and VGA board with two ports (one port links to the screen, another to the projector). The software of system consists of grating projection module, image grabbing module, phase reconstructing module and 3D display module. A software-based synchronizing method between grating projection and image capture is proposed. As for the nonlinear error of captured fringes, a compensating method is introduced based on the pixel-to-pixel gray correction. At the same time, a least square phase unwrapping is used to solve the problem of phase reconstruction by using the combination of Log Modulation Amplitude and Phase Derivative Variance (LMAPDV) as weight. The system adopts an algorithm from Matlab Tool Box for camera calibration. The 3D measurement system has an accuracy of 0.05mm. The execution time of system is 3~5s for one-time measurement.

  1. Low-Amplitude Craniofacial EMG Power Spectral Density and 3D Muscle Reconstruction from MRI

    PubMed Central

    Wiedemann, Lukas; Chaberova, Jana; Edmunds, Kyle; Einarsdóttir, Guðrún; Ramon, Ceon

    2015-01-01

    Improving EEG signal interpretation, specificity, and sensitivity is a primary focus of many current investigations, and the successful application of EEG signal processing methods requires a detailed knowledge of both the topography and frequency spectra of low-amplitude, high-frequency craniofacial EMG. This information remains limited in clinical research, and as such, there is no known reliable technique for the removal of these artifacts from EEG data. The results presented herein outline a preliminary investigation of craniofacial EMG high-frequency spectra and 3D MRI segmentation that offers insight into the development of an anatomically-realistic model for characterizing these effects. The data presented highlights the potential for confounding signal contribution from around 60 to 200 Hz, when observed in frequency space, from both low and high-amplitude EMG signals. This range directly overlaps that of both low γ (30-50 Hz) and high γ (50-80 Hz) waves, as defined traditionally in standatrd EEG measurements, and mainly with waves presented in dense-array EEG recordings. Likewise, average EMG amplitude comparisons from each condition highlights the similarities in signal contribution of low-activity muscular movements and resting, control conditions. In addition to the FFT analysis performed, 3D segmentation and reconstruction of the craniofacial muscles whose EMG signals were measured was successful. This recapitulation of the relevant EMG morphology is a crucial first step in developing an anatomical model for the isolation and removal of confounding low-amplitude craniofacial EMG signals from EEG data. Such a model may be eventually applied in a clinical setting to ultimately help to extend the use of EEG in various clinical roles. PMID:26913150

  2. Voice and gesture-based 3D multimedia presentation tool

    NASA Astrophysics Data System (ADS)

    Fukutake, Hiromichi; Akazawa, Yoshiaki; Okada, Yoshihiro

    2007-09-01

    This paper proposes a 3D multimedia presentation tool that allows the user to manipulate intuitively only through the voice input and the gesture input without using a standard keyboard or a mouse device. The authors developed this system as a presentation tool to be used in a presentation room equipped a large screen like an exhibition room in a museum because, in such a presentation environment, it is better to use voice commands and the gesture pointing input rather than using a keyboard or a mouse device. This system was developed using IntelligentBox, which is a component-based 3D graphics software development system. IntelligentBox has already provided various types of 3D visible, reactive functional components called boxes, e.g., a voice input component and various multimedia handling components. IntelligentBox also provides a dynamic data linkage mechanism called slot-connection that allows the user to develop 3D graphics applications by combining already existing boxes through direct manipulations on a computer screen. Using IntelligentBox, the 3D multimedia presentation tool proposed in this paper was also developed as combined components only through direct manipulations on a computer screen. The authors have already proposed a 3D multimedia presentation tool using a stage metaphor and its voice input interface. This time, we extended the system to make it accept the user gesture input besides voice commands. This paper explains details of the proposed 3D multimedia presentation tool and especially describes its component-based voice and gesture input interfaces.

  3. Deep MRI brain extraction: A 3D convolutional neural network for skull stripping.

    PubMed

    Kleesiek, Jens; Urban, Gregor; Hubert, Alexander; Schwarz, Daniel; Maier-Hein, Klaus; Bendszus, Martin; Biller, Armin

    2016-04-01

    Brain extraction from magnetic resonance imaging (MRI) is crucial for many neuroimaging workflows. Current methods demonstrate good results on non-enhanced T1-weighted images, but struggle when confronted with other modalities and pathologically altered tissue. In this paper we present a 3D convolutional deep learning architecture to address these shortcomings. In contrast to existing methods, we are not limited to non-enhanced T1w images. When trained appropriately, our approach handles an arbitrary number of modalities including contrast-enhanced scans. Its applicability to MRI data, comprising four channels: non-enhanced and contrast-enhanced T1w, T2w and FLAIR contrasts, is demonstrated on a challenging clinical data set containing brain tumors (N=53), where our approach significantly outperforms six commonly used tools with a mean Dice score of 95.19. Further, the proposed method at least matches state-of-the-art performance as demonstrated on three publicly available data sets: IBSR, LPBA40 and OASIS, totaling N=135 volumes. For the IBSR (96.32) and LPBA40 (96.96) data set the convolutional neuronal network (CNN) obtains the highest average Dice scores, albeit not being significantly different from the second best performing method. For the OASIS data the second best Dice (95.02) results are achieved, with no statistical difference in comparison to the best performing tool. For all data sets the highest average specificity measures are evaluated, whereas the sensitivity displays about average results. Adjusting the cut-off threshold for generating the binary masks from the CNN's probability output can be used to increase the sensitivity of the method. Of course, this comes at the cost of a decreased specificity and has to be decided application specific. Using an optimized GPU implementation predictions can be achieved in less than one minute. The proposed method may prove useful for large-scale studies and clinical trials. Copyright © 2016 Elsevier Inc. All

  4. Robust 3D ATR techniques based on geometric invariants

    NASA Astrophysics Data System (ADS)

    Jeffris, M. A.

    2005-05-01

    Automatic target classification in general is complicated owing to the influence of pose, articulation, and overall viewing geometry on two dimensional SAR data. Three dimensional (3D) data, however, affords the opportunity to develop robust classification techniques independent of those issues. Based on geometric invariants, discriminants can be obtained assuming the target or its phase center lattice can be well modelled by 3D geometries subject to independent rigid body motions, (i.e. reflection, rotation, and translation). Toward this end, we present recent results in the development of a unique 3D classification algorithm. The concepts herein are developed for the full 3D observation space. In particular, we discuss several discrimination metrics based on a target's geometry. As such, they are necessarily invariant to pose and articulation and consequently provide robust classification performance. These geometric-invariant discriminants are concisely expressed as equations unique to a single target structure, or to the spatial interrelationships of multiple structures (this addresses the articulation problem). Once established, these equations can subsequently be used to properly classify the structure or structures at a later time without the need for explicit knowledge of the 3D orientation of the structures within the field of view. We present the mathematical basis behind these classification schemes, discuss implementation concepts, and finish by demonstrating these techniques on synthetic data.

  5. Isotropic 3D Black Blood MRI of Abdominal Aortic Aneurysm Wall and Intraluminal Thrombus

    PubMed Central

    Zhu, Chengcheng; Haraldsson, Henrik; Faraji, Farshid; Owens, Christopher; Gasper, Warren; Ahn, Sinyeob; Liu, Jing; Laub, Gerhard; Hope, Michael D.; Saloner, David

    2015-01-01

    Introduction The aortic wall and intraluminal thrombus (ILT) have been increasingly studied as potential markers of progressive disease with abdominal aortic aneurysms (AAAs). Our goal was to develop a high resolution, 3D black blood MR technique for AAA wall and ILT imaging within a clinically acceptable scan time. Methods Twenty two patients with AAAs (maximal diameter 4.3±1.0cm), along with five healthy volunteers, were imaged at 3T with a 3D T1-weighted fast-spin-echo sequence using variable flip angle trains (SPACE) with a preparation pulse (DANTE) for suppressing blood signal. Volunteers and ten patients were also scanned with SPACE alone for comparison purposes. The signal to noise ratio (SNR) and the aortic wall/ILT to lumen contrast to noise ratio (CNR) were measured. Qualitative image scores (1–4 scale) assessing the inner lumen and outer wall boundaries of AAA were performed by two blinded reviewers. In patients with ILT, the ratio of ILT signal intensity (ILTSI) over psoas muscle SI (MuscleSI) was calculated, and the signal heterogeneity of ILT was quantified as standard deviation (SD) over the mean. Results All subjects were imaged successfully with an average scan time of 7.8±0.7 minutes. The DANTE preparation pulse for blood suppression substantially reduced flow artifacts in SPACE with lower lumen SNR (8.8 vs. 21.4, p<0.001) and improved the wall/ILT to lumen CNR (9.9 vs. 6.3, p<0.001) in patients. Qualitative assessment showed improved visualization of lumen boundaries (73% higher scores on average, p=0.01) and comparable visualization of outer wall boundary (p>0.05). ILT was present in ten patients, with relatively high signal and a wide SD (average ILTSI/MuscleSI 1.42±0.48 (range 0.75–2.11) ) and with SD/mean of 27.7%±6.6% (range 19.6% – 39.4%). Conclusion High resolution, 3D black blood MRI of AAAs can be achieved in a clinical accepted scan time with reduction of flow artifacts using the DANTE preparation pulse. Signal characteristics

  6. Interactive algorithms for the segmentation and quantitation of 3-D MRI brain scans.

    PubMed

    Freeborough, P A; Fox, N C; Kitney, R I

    1997-05-01

    Interactive algorithms are an attractive approach to the accurate segmentation of 3D brain scans as they potentially improve the reliability of fully automated segmentation while avoiding the labour intensiveness and inaccuracies of manual segmentation. We present a 3D image analysis package (MIDAS) with a novel architecture enabling highly interactive segmentation algorithms to be implemented as add on modules. Interactive methods based on intensity thresholding, region growing and the constrained application of morphological operators are also presented. The methods involve the application of constraints and freedoms on the algorithms coupled with real time visualisation of the effect. This methodology has been applied to the segmentation, visualisation and measurement of the whole brain and a small irregular neuroanatomical structure, the hippocampus. We demonstrate reproducible and anatomically accurate segmentations of these structures. The efficacy of one method in measuring volume loss (atrophy) of the hippocampus in Alzheimer's disease is shown and is compared to conventional methods.

  7. 3-D carotid multi-region MRI segmentation by globally optimal evolution of coupled surfaces.

    PubMed

    Ukwatta, Eranga; Yuan, Jing; Rajchl, Martin; Qiu, Wu; Tessier, David; Fenster, Aaron

    2013-04-01

    In this paper, we propose a novel global optimization based 3-D multi-region segmentation algorithm for T1-weighted black-blood carotid magnetic resonance (MR) images. The proposed algorithm partitions a 3-D carotid MR image into three regions: wall, lumen, and background. The algorithm performs such partitioning by simultaneously evolving two coupled 3-D surfaces of carotid artery adventitia boundary (AB) and lumen-intima boundary (LIB) while preserving their anatomical inter-surface consistency such that the LIB is always located within the AB. In particular, we show that the proposed algorithm results in a fully time implicit scheme that propagates the two linearly ordered surfaces of the AB and LIB to their globally optimal positions during each discrete time frame by convex relaxation. In this regard, we introduce the continuous max-flow model and prove its duality/equivalence to the convex relaxed optimization problem with respect to each evolution step. We then propose a fully parallelized continuous max-flow-based algorithm, which can be readily implemented on a GPU to achieve high computational efficiency. Extensive experiments, with four users using 12 3T MR and 26 1.5T MR images, demonstrate that the proposed algorithm yields high accuracy and low operator variability in computing vessel wall volume. In addition, we show the algorithm outperforms previous methods in terms of high computational efficiency and robustness with fewer user interactions.

  8. Characteristics of neurovascular compression in facial neuralgia patients by 3D high-resolution MRI and fusion technology.

    PubMed

    Guo, Zi-Yi; Chen, Jing; Yang, Guang; Tang, Qian-Yu; Chen, Cai-Xiang; Fu, Shui-Xi; Yu, Dan

    2012-12-01

    To evaluate the anatomical characteristics and patterns of neurovascular compression in patients suffering trigeminal neuralgia, using 3D high-resolution magnetic resonance imaging methods and fusion technologies. The analysis of the anatomy of the facial nerve, brain stem and the vascular structures related to this nerve was made in 100 consecutive patients for TN. 3D high resolution MRI studies (3D SPGR, T1 enhanced 3D MP-RAGE and T2/T1 3D FIESTA) simultaneous visualization were used to assessed using the software 3D DOCTOR. In 93 patients (93%), there were one or several locals of neurovascular compression (NVC). The superior cerebellar artery was involved in 71 cases (76%), the other vessels including the antero-inferior cerebellar artery, the basilar artery, the vertebral artery, and some venous structures. The mean distance between NVC and nerve origin site in the brainstem was (3.76 ± 2.90) mm). In 39 patients (42%), the vascular compression was located proximally and in 42 (45%) the compression was located distally. Nerve dislocation or distortion by the vessel was observed in 30 cases (32%). This 3D high resolution MRI and image fusion technology could be useful for diagnostic and therapeutic decisions in TN. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  9. Fast Bayesian whole-brain fMRI analysis with spatial 3D priors.

    PubMed

    Sidén, Per; Eklund, Anders; Bolin, David; Villani, Mattias

    2017-02-01

    Spatial whole-brain Bayesian modeling of task-related functional magnetic resonance imaging (fMRI) is a great computational challenge. Most of the currently proposed methods therefore do inference in subregions of the brain separately or do approximate inference without comparison to the true posterior distribution. A popular such method, which is now the standard method for Bayesian single subject analysis in the SPM software, is introduced in Penny et al. (2005b). The method processes the data slice-by-slice and uses an approximate variational Bayes (VB) estimation algorithm that enforces posterior independence between activity coefficients in different voxels. We introduce a fast and practical Markov chain Monte Carlo (MCMC) scheme for exact inference in the same model, both slice-wise and for the whole brain using a 3D prior on activity coefficients. The algorithm exploits sparsity and uses modern techniques for efficient sampling from high-dimensional Gaussian distributions, leading to speed-ups without which MCMC would not be a practical option. Using MCMC, we are for the first time able to evaluate the approximate VB posterior against the exact MCMC posterior, and show that VB can lead to spurious activation. In addition, we develop an improved VB method that drops the assumption of independent voxels a posteriori. This algorithm is shown to be much faster than both MCMC and the original VB for large datasets, with negligible error compared to the MCMC posterior.

  10. Hough transform-based 3D mesh retrieval

    NASA Astrophysics Data System (ADS)

    Zaharia, Titus; Preteux, Francoise J.

    2001-11-01

    This papre addresses the issue of 3D mesh indexation by using shape descriptors (SDs) under constraints of geometric and topological invariance. A new shape descriptor, the Optimized 3D Hough Transform Descriptor (O3HTD) is here proposed. Intrinsically topologically stable, the O3DHTD is not invariant to geometric transformations. Nevertheless, we show mathematically how the O3DHTD can be optimally associated (in terms of compactness of representation and computational complexity) with a spatial alignment procedure which leads to a geometric invariant behavior. Experimental results have been carried out upon the MPEG-7 3D model database consisting of about 1300 meshes in VRML 2.0 format. Objective retrieval results, based upon the definition of a categorized ground truth subset, are reported in terms of Bull Eye Percentage (BEP) score and compared to those obtained by applying the MPEg-7 3D SD. It is shown that the O3DHTD outperforms the MPEg-7 3D SD of up to 28%.

  11. Optical 3D watermark based digital image watermarking for telemedicine

    NASA Astrophysics Data System (ADS)

    Li, Xiao Wei; Kim, Seok Tae

    2013-12-01

    Region of interest (ROI) of a medical image is an area including important diagnostic information and must be stored without any distortion. This algorithm for application of watermarking technique for non-ROI of the medical image preserving ROI. The paper presents a 3D watermark based medical image watermarking scheme. In this paper, a 3D watermark object is first decomposed into 2D elemental image array (EIA) by a lenslet array, and then the 2D elemental image array data is embedded into the host image. The watermark extraction process is an inverse process of embedding. The extracted EIA through the computational integral imaging reconstruction (CIIR) technique, the 3D watermark can be reconstructed. Because the EIA is composed of a number of elemental images possesses their own perspectives of a 3D watermark object. Even though the embedded watermark data badly damaged, the 3D virtual watermark can be successfully reconstructed. Furthermore, using CAT with various rule number parameters, it is possible to get many channels for embedding. So our method can recover the weak point having only one transform plane in traditional watermarking methods. The effectiveness of the proposed watermarking scheme is demonstrated with the aid of experimental results.

  12. Multicore-based 3D-DWT video encoder

    NASA Astrophysics Data System (ADS)

    Galiano, Vicente; López-Granado, Otoniel; Malumbres, Manuel P.; Migallón, Hector

    2013-12-01

    Three-dimensional wavelet transform (3D-DWT) encoders are good candidates for applications like professional video editing, video surveillance, multi-spectral satellite imaging, etc. where a frame must be reconstructed as quickly as possible. In this paper, we present a new 3D-DWT video encoder based on a fast run-length coding engine. Furthermore, we present several multicore optimizations to speed-up the 3D-DWT computation. An exhaustive evaluation of the proposed encoder (3D-GOP-RL) has been performed, and we have compared the evaluation results with other video encoders in terms of rate/distortion (R/D), coding/decoding delay, and memory consumption. Results show that the proposed encoder obtains good R/D results for high-resolution video sequences with nearly in-place computation using only the memory needed to store a group of pictures. After applying the multicore optimization strategies over the 3D DWT, the proposed encoder is able to compress a full high-definition video sequence in real-time.

  13. Applications of Alginate-Based Bioinks in 3D Bioprinting

    PubMed Central

    Axpe, Eneko; Oyen, Michelle L.

    2016-01-01

    Three-dimensional (3D) bioprinting is on the cusp of permitting the direct fabrication of artificial living tissue. Multicellular building blocks (bioinks) are dispensed layer by layer and scaled for the target construct. However, only a few materials are able to fulfill the considerable requirements for suitable bioink formulation, a critical component of efficient 3D bioprinting. Alginate, a naturally occurring polysaccharide, is clearly the most commonly employed material in current bioinks. Here, we discuss the benefits and disadvantages of the use of alginate in 3D bioprinting by summarizing the most recent studies that used alginate for printing vascular tissue, bone and cartilage. In addition, other breakthroughs in the use of alginate in bioprinting are discussed, including strategies to improve its structural and degradation characteristics. In this review, we organize the available literature in order to inspire and accelerate novel alginate-based bioink formulations with enhanced properties for future applications in basic research, drug screening and regenerative medicine. PMID:27898010

  14. GPU-based 3D lower tree wavelet video encoder

    NASA Astrophysics Data System (ADS)

    Galiano, Vicente; López-Granado, Otoniel; Malumbres, Manuel P.; Drummond, Leroy Anthony; Migallón, Hector

    2013-12-01

    The 3D-DWT is a mathematical tool of increasing importance in those applications that require an efficient processing of huge amounts of volumetric info. Other applications like professional video editing, video surveillance applications, multi-spectral satellite imaging, HQ video delivery, etc, would rather use 3D-DWT encoders to reconstruct a frame as fast as possible. In this article, we introduce a fast GPU-based encoder which uses 3D-DWT transform and lower trees. Also, we present an exhaustive analysis of the use of GPU memory. Our proposal shows good trade off between R/D, coding delay (as fast as MPEG-2 for High definition) and memory requirements (up to 6 times less memory than x264).

  15. Applications of Alginate-Based Bioinks in 3D Bioprinting.

    PubMed

    Axpe, Eneko; Oyen, Michelle L

    2016-11-25

    Three-dimensional (3D) bioprinting is on the cusp of permitting the direct fabrication of artificial living tissue. Multicellular building blocks (bioinks) are dispensed layer by layer and scaled for the target construct. However, only a few materials are able to fulfill the considerable requirements for suitable bioink formulation, a critical component of efficient 3D bioprinting. Alginate, a naturally occurring polysaccharide, is clearly the most commonly employed material in current bioinks. Here, we discuss the benefits and disadvantages of the use of alginate in 3D bioprinting by summarizing the most recent studies that used alginate for printing vascular tissue, bone and cartilage. In addition, other breakthroughs in the use of alginate in bioprinting are discussed, including strategies to improve its structural and degradation characteristics. In this review, we organize the available literature in order to inspire and accelerate novel alginate-based bioink formulations with enhanced properties for future applications in basic research, drug screening and regenerative medicine.

  16. Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues.

    PubMed

    Ries, Mario; de Senneville, Baudouin Denis; Roujol, Sébastien; Berber, Yasmina; Quesson, Bruno; Moonen, Chrit

    2010-12-01

    Magnetic resonance imaging-guided high intensity focused ultrasound is a promising method for the noninvasive ablation of pathological tissue in abdominal organs such as liver and kidney. Due to the high perfusion rates of these organs, sustained sonications are required to achieve a sufficiently high temperature elevation to induce necrosis. However, the constant displacement of the target due to the respiratory cycle render continuous ablations challenging, since dynamic repositioning of the focal point is required. This study demonstrates subsecond 3D high intensity focused ultrasound-beam steering under magnetic resonance-guidance for the real-time compensation of respiratory motion. The target is observed in 3D space by coupling rapid 2D magnetic resonance-imaging with prospective slice tracking based on pencil-beam navigator echoes. The magnetic resonance-data is processed in real-time by a computationally efficient reconstruction pipeline, which provides the position, the temperature and the thermal dose on-the-fly, and which feeds corrections into the high intensity focused ultrasound-ablator. The effect of the residual update latency is reduced by using a 3D Kalman-predictor for trajectory anticipation. The suggested method is characterized with phantom experiments and verified in vivo on porcine kidney. The results show that for update frequencies of more than 10 Hz and latencies of less then 114 msec, temperature elevations can be achieved, which are comparable to static experiments. Copyright © 2010 Wiley-Liss, Inc.

  17. Perception-based shape retrieval for 3D building models

    NASA Astrophysics Data System (ADS)

    Zhang, Man; Zhang, Liqiang; Takis Mathiopoulos, P.; Ding, Yusi; Wang, Hao

    2013-01-01

    With the help of 3D search engines, a large number of 3D building models can be retrieved freely online. A serious disadvantage of most rotation-insensitive shape descriptors is their inability to distinguish between two 3D building models which are different at their main axes, but appear similar when one of them is rotated. To resolve this problem, we present a novel upright-based normalization method which not only correctly rotates such building models, but also greatly simplifies and accelerates the abstraction and the matching of building models' shape descriptors. Moreover, the abundance of architectural styles significantly hinders the effective shape retrieval of building models. Our research has shown that buildings with different designs are not well distinguished by the widely recognized shape descriptors for general 3D models. Motivated by this observation and to further improve the shape retrieval quality, a new building matching method is introduced and analyzed based on concepts found in the field of perception theory and the well-known Light Field descriptor. The resulting normalized building models are first classified using the qualitative shape descriptors of Shell and Unevenness which outline integral geometrical and topological information. These models are then put in on orderly fashion with the help of an improved quantitative shape descriptor which we will term as Horizontal Light Field Descriptor, since it assembles detailed shape characteristics. To accurately evaluate the proposed methodology, an enlarged building shape database which extends previous well-known shape benchmarks was implemented as well as a model retrieval system supporting inputs from 2D sketches and 3D models. Various experimental performance evaluation results have shown that, as compared to previous methods, retrievals employing the proposed matching methodology are faster and more consistent with human recognition of spatial objects. In addition these performance

  18. Image-driven, model-based 3D abdominal motion estimation for MR-guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Stemkens, Bjorn; Tijssen, Rob H. N.; de Senneville, Baudouin Denis; Lagendijk, Jan J. W.; van den Berg, Cornelis A. T.

    2016-07-01

    Respiratory motion introduces substantial uncertainties in abdominal radiotherapy for which traditionally large margins are used. The MR-Linac will open up the opportunity to acquire high resolution MR images just prior to radiation and during treatment. However, volumetric MRI time series are not able to characterize 3D tumor and organ-at-risk motion with sufficient temporal resolution. In this study we propose a method to estimate 3D deformation vector fields (DVFs) with high spatial and temporal resolution based on fast 2D imaging and a subject-specific motion model based on respiratory correlated MRI. In a pre-beam phase, a retrospectively sorted 4D-MRI is acquired, from which the motion is parameterized using a principal component analysis. This motion model is used in combination with fast 2D cine-MR images, which are acquired during radiation, to generate full field-of-view 3D DVFs with a temporal resolution of 476 ms. The geometrical accuracies of the input data (4D-MRI and 2D multi-slice acquisitions) and the fitting procedure were determined using an MR-compatible motion phantom and found to be 1.0-1.5 mm on average. The framework was tested on seven healthy volunteers for both the pancreas and the kidney. The calculated motion was independently validated using one of the 2D slices, with an average error of 1.45 mm. The calculated 3D DVFs can be used retrospectively for treatment simulations, plan evaluations, or to determine the accumulated dose for both the tumor and organs-at-risk on a subject-specific basis in MR-guided radiotherapy.

  19. 3D phase unwrapping using global expected phase as a reference: application to MRI global shimming.

    PubMed

    Liu, Wentao; Tang, Xin; Ma, Yajun; Gao, Jia-Hong

    2013-07-01

    MRI phase data often suffers from phase wrapping (i.e., phase may be discontinuous by 2π jumps). Numerous MRI phase unwrapping strategies were developed in the past using a criterion based on phase information of local or neighboring voxels. In this study, an alternative and novel three dimensional phase unwrapping strategy is introduced. This method considers the global character of the phase distribution and utilizes continuous trigonometric functions to construct an expected phase map as an unwrapping reference, which is then used to guide the phase correction of every individual voxel. The original phase is estimated by analyzing the derivative of the wrapped phase image. Simulations of various phase wrapped situations were performed and this new method was also used for an in vivo application (i.e., MRI automatic global shimming). Both simulated and experimental results demonstrate that our proposed method is more reliable and robust than traditional algorithms at obtaining correct phase maps, especially in regions of low-signal and air cavities, such as the abdomen and pelvis.

  20. 3D Ear Identification Based on Sparse Representation

    PubMed Central

    Zhang, Lin; Ding, Zhixuan; Li, Hongyu; Shen, Ying

    2014-01-01

    Biometrics based personal authentication is an effective way for automatically recognizing, with a high confidence, a person’s identity. Recently, 3D ear shape has attracted tremendous interests in research field due to its richness of feature and ease of acquisition. However, the existing ICP (Iterative Closet Point)-based 3D ear matching methods prevalent in the literature are not quite efficient to cope with the one-to-many identification case. In this paper, we aim to fill this gap by proposing a novel effective fully automatic 3D ear identification system. We at first propose an accurate and efficient template-based ear detection method. By utilizing such a method, the extracted ear regions are represented in a common canonical coordinate system determined by the ear contour template, which facilitates much the following stages of feature extraction and classification. For each extracted 3D ear, a feature vector is generated as its representation by making use of a PCA-based local feature descriptor. At the stage of classification, we resort to the sparse representation based classification approach, which actually solves an l1-minimization problem. To the best of our knowledge, this is the first work introducing the sparse representation framework into the field of 3D ear identification. Extensive experiments conducted on a benchmark dataset corroborate the effectiveness and efficiency of the proposed approach. The associated Matlab source code and the evaluation results have been made publicly online available at http://sse.tongji.edu.cn/linzhang/ear/srcear/srcear.htm. PMID:24740247

  1. Qualitative Evaluation of a High-Resolution 3D Multi-Sequence Intracranial Vessel Wall Protocol at 3 Tesla MRI.

    PubMed

    Dieleman, Nikki; Yang, Wenjie; van der Kolk, Anja G; Abrigo, Jill; Lee, Ka Lok; Chu, Winnie Chiu Wing; Zwanenburg, Jaco J M; Siero, Jeroen C W; Wong, Ka Sing; Hendrikse, Jeroen; Chen, Fiona Xiang Yan

    2016-01-01

    Intracranial vessel wall imaging using MRI has great potential as a clinical method for assessing intracranial atherosclerosis. The purpose of the current study was to compare three 3T MRI vessel wall sequences with different contrast weightings (T1w, PD, T2w) and dedicated sagittal orientation perpendicular to the middle cerebral artery, to the reconstructed sagittal image from a transverse 3D T1w volumetric isotropically reconstructed turbo spin-echo acquisition (VIRTA), and provide a clinical recommendation. The above-mentioned sequences were acquired in 10 consecutive Chinese ischemic stroke or TIA patients (age: 68 years, sex: 4 females) with angiographic-confirmed MCA stenosis at 3T. Institutional review board approval was obtained. Two raters qualitatively scored all images on overall image quality, presence of artifacts, and visibility of plaques. Data were compared using Repeated measures ANOVA and Sidak's adjusted post hoc tests. All sequences except the T2w sequence were able to depict the walls of the large vessels of the Circle of Willis (p<0.05). T1w sagittal oblique VIRTA showed significantly more artifacts (p<0.01). Peripherally located plaques were sometimes missed on the sagittal sequences, but could be appreciated on the transverse T1w VIRTA. With the 3T multi-sequence vessel wall protocol we were able to assess the intracranial plaque with two different image contrast weightings. The sequence of preference to include in a clinical protocol would be the transverse 3D T1w VIRTA based on absence of artifacts, larger coverage including the whole Circle of Willis, and excellent lesion depiction.

  2. USPIO-enhanced 3D-cine self-gated cardiac MRI based on a stack-of-stars golden angle short echo time sequence: Application on mice with acute myocardial infarction.

    PubMed

    Trotier, Aurélien J; Castets, Charles R; Lefrançois, William; Ribot, Emeline J; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain

    2016-08-01

    To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 μm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P < 0.05), enabling reducing the acquisition time to 15 minutes. EF was significantly different between healthy and MI mice (P < 0.05). The method proposed here showed that 3D-cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365. © 2016 Wiley Periodicals, Inc.

  3. A variable flip angle-based method for reducing blurring in 3D GRASE ASL

    NASA Astrophysics Data System (ADS)

    Liang, Xiaoyun; Connelly, Alan; Tournier, Jacques-Donald; Calamante, Fernando

    2014-09-01

    Arterial Spin Labeling (ASL) is an MRI technique to measure cerebral blood flow directly and noninvasively, and thus provides a more direct quantitative correlate of neural activity than blood-oxygen-level-dependent fMRI. A 3D gradient and spin-echo (GRASE) sequence is capable of enhancing signal-to-noise ratio, and has been shown to be a very useful readout module for ASL sequences. Nonetheless, the introduction of significant blurring in its single-shot version, due to T2 decay along the partition dimension, compromises the achievable spatial resolution, limiting the potential of this technique for whole-brain coverage. To address this issue, a method for reducing blurring based on a variable flip angle (VFA) scheme is proposed in this study for 3D GRASE ASL perfusion. Numerical simulations show that the proposed method is capable of reducing the blurring significantly compared to the standard constant flip angle approach; this result was further confirmed using in vivo data. The proposed VFA method should therefore be of significance to 3D GRASE ASL fMRI studies, since it is able to reduce blurring without sacrificing temporal resolution.

  4. Reconstruction of freehand 3D ultrasound based on kernel regression.

    PubMed

    Chen, Xiankang; Wen, Tiexiang; Li, Xingmin; Qin, Wenjian; Lan, Donglai; Pan, Weizhou; Gu, Jia

    2014-08-28

    Freehand three-dimensional (3D) ultrasound has the advantages of flexibility for allowing clinicians to manipulate the ultrasound probe over the examined body surface with less constraint in comparison with other scanning protocols. Thus it is widely used in clinical diagnose and image-guided surgery. However, as the data scanning of freehand-style is subjective, the collected B-scan images are usually irregular and highly sparse. One of the key procedures in freehand ultrasound imaging system is the volume reconstruction, which plays an important role in improving the reconstructed image quality. A novel freehand 3D ultrasound volume reconstruction method based on kernel regression model is proposed in this paper. Our method consists of two steps: bin-filling and regression. Firstly, the bin-filling step is used to map each pixel in the sampled B-scan images to its corresponding voxel in the reconstructed volume data. Secondly, the regression step is used to make the nonparametric estimation for the whole volume data from the previous sampled sparse data. The kernel penalizes distance away from the current approximation center within a local neighborhood. To evaluate the quality and performance of our proposed kernel regression algorithm for freehand 3D ultrasound reconstruction, a phantom and an in-vivo liver organ of human subject are scanned with our freehand 3D ultrasound imaging system. Root mean square error (RMSE) is used for the quantitative evaluation. Both of the qualitative and quantitative experimental results demonstrate that our method can reconstruct image with less artifacts and higher quality. The proposed kernel regression based reconstruction method is capable of constructing volume data with improved accuracy from irregularly sampled sparse data for freehand 3D ultrasound imaging system.

  5. Structured Light-Based 3D Reconstruction System for Plants.

    PubMed

    Nguyen, Thuy Tuong; Slaughter, David C; Max, Nelson; Maloof, Julin N; Sinha, Neelima

    2015-07-29

    Camera-based 3D reconstruction of physical objects is one of the most popular computer vision trends in recent years. Many systems have been built to model different real-world subjects, but there is lack of a completely robust system for plants. This paper presents a full 3D reconstruction system that incorporates both hardware structures (including the proposed structured light system to enhance textures on object surfaces) and software algorithms (including the proposed 3D point cloud registration and plant feature measurement). This paper demonstrates the ability to produce 3D models of whole plants created from multiple pairs of stereo images taken at different viewing angles, without the need to destructively cut away any parts of a plant. The ability to accurately predict phenotyping features, such as the number of leaves, plant height, leaf size and internode distances, is also demonstrated. Experimental results show that, for plants having a range of leaf sizes and a distance between leaves appropriate for the hardware design, the algorithms successfully predict phenotyping features in the target crops, with a recall of 0.97 and a precision of 0.89 for leaf detection and less than a 13-mm error for plant size, leaf size and internode distance.

  6. Structured Light-Based 3D Reconstruction System for Plants

    PubMed Central

    Nguyen, Thuy Tuong; Slaughter, David C.; Max, Nelson; Maloof, Julin N.; Sinha, Neelima

    2015-01-01

    Camera-based 3D reconstruction of physical objects is one of the most popular computer vision trends in recent years. Many systems have been built to model different real-world subjects, but there is lack of a completely robust system for plants.This paper presents a full 3D reconstruction system that incorporates both hardware structures (including the proposed structured light system to enhance textures on object surfaces) and software algorithms (including the proposed 3D point cloud registration and plant feature measurement). This paper demonstrates the ability to produce 3D models of whole plants created from multiple pairs of stereo images taken at different viewing angles, without the need to destructively cut away any parts of a plant. The ability to accurately predict phenotyping features, such as the number of leaves, plant height, leaf size and internode distances, is also demonstrated. Experimental results show that, for plants having a range of leaf sizes and a distance between leaves appropriate for the hardware design, the algorithms successfully predict phenotyping features in the target crops, with a recall of 0.97 and a precision of 0.89 for leaf detection and less than a 13-mm error for plant size, leaf size and internode distance. PMID:26230701

  7. 3D geometry-based quantification of colocalizations in multichannel 3D microscopy images of human soft tissue tumors.

    PubMed

    Wörz, Stefan; Sander, Petra; Pfannmöller, Martin; Rieker, Ralf J; Joos, Stefan; Mechtersheimer, Gunhild; Boukamp, Petra; Lichter, Peter; Rohr, Karl

    2010-08-01

    We introduce a new model-based approach for automatic quantification of colocalizations in multichannel 3D microscopy images. The approach uses different 3D parametric intensity models in conjunction with a model fitting scheme to localize and quantify subcellular structures with high accuracy. The central idea is to determine colocalizations between different channels based on the estimated geometry of the subcellular structures as well as to differentiate between different types of colocalizations. A statistical analysis was performed to assess the significance of the determined colocalizations. This approach was used to successfully analyze about 500 three-channel 3D microscopy images of human soft tissue tumors and controls.

  8. High-resolution MRI of the intraparotid facial nerve based on a microsurface coil and a 3D reversed fast imaging with steady-state precession DWI sequence at 3T.

    PubMed

    Chu, J; Zhou, Z; Hong, G; Guan, J; Li, S; Rao, L; Meng, Q; Yang, Z

    2013-08-01

    3D high-resolution MR imaging can provide reliable information for defining the exact relationships between the intraparotid facial nerve and adjacent structures. The purpose of this study was to explore the clinical value of using a surface coil combined with a 3D-PSIF-DWI sequence in intraparotid facial nerve imaging. Twenty-one healthy volunteers underwent intraparotid facial nerve scanning at 3T by using the 3D-PSIF-DWI sequence with both the surface coil and the head coil. Source images were processed with MIP and MPR to better delineate the intraparotid facial nerve and its branches. In addition, the SIR of the facial nerve and parotid gland was calculated. The number of facial nerve branches displayed by these 2 methods was calculated and compared. The display rates of the main trunk, divisions (cervicofacial, temporofacial), and secondary branches of the intraparotid facial nerve were 100%, 97.6%, and 51.4% by head coil and 100%, 100%, and 83.8% by surface coil, respectively. The display rate of secondary branches of the intraparotid facial nerve by these 2 methods was significantly different (P < .05). The SIRs of the intraparotid facial nerve/parotid gland in these 2 methods were significantly different (P < .05) at 1.37 ± 1.06 and 1.89 ± 0.87, respectively. The 3D-PSIF-DWI sequence combined with a surface coil can better delineate the intraparotid facial nerve and its divisions than when it is combined with a head coil, providing better image contrast and resolution. The proposed protocol offers a potentially useful noninvasive imaging sequence for intraparotid facial nerve imaging at 3T.

  9. Visual fatigue evaluation based on depth in 3D videos

    NASA Astrophysics Data System (ADS)

    Wang, Feng-jiao; Sang, Xin-zhu; Liu, Yangdong; Shi, Guo-zhong; Xu, Da-xiong

    2013-08-01

    In recent years, 3D technology has become an emerging industry. However, visual fatigue always impedes the development of 3D technology. In this paper we propose some factors affecting human perception of depth as new quality metrics. These factors are from three aspects of 3D video--spatial characteristics, temporal characteristics and scene movement characteristics. They play important roles for the viewer's visual perception. If there are many objects with a certain velocity and the scene changes fast, viewers will feel uncomfortable. In this paper, we propose a new algorithm to calculate the weight values of these factors and analyses their effect on visual fatigue.MSE (Mean Square Error) of different blocks is taken into consideration from the frame and inter-frame for 3D stereoscopic videos. The depth frame is divided into a number of blocks. There are overlapped and sharing pixels (at half of the block) in the horizontal and vertical direction. Ignoring edge information of objects in the image can be avoided. Then the distribution of all these data is indicated by kurtosis with regard of regions which human eye may mainly gaze at. Weight values can be gotten by the normalized kurtosis. When the method is used for individual depth, spatial variation can be achieved. When we use it in different frames between current and previous one, we can get temporal variation and scene movement variation. Three factors above are linearly combined, so we can get objective assessment value of 3D videos directly. The coefficients of three factors can be estimated based on the liner regression. At last, the experimental results show that the proposed method exhibits high correlation with subjective quality assessment results.

  10. 3-D model-based tracking for UAV indoor localization.

    PubMed

    Teulière, Céline; Marchand, Eric; Eck, Laurent

    2015-05-01

    This paper proposes a novel model-based tracking approach for 3-D localization. One main difficulty of standard model-based approach lies in the presence of low-level ambiguities between different edges. In this paper, given a 3-D model of the edges of the environment, we derive a multiple hypotheses tracker which retrieves the potential poses of the camera from the observations in the image. We also show how these candidate poses can be integrated into a particle filtering framework to guide the particle set toward the peaks of the distribution. Motivated by the UAV indoor localization problem where GPS signal is not available, we validate the algorithm on real image sequences from UAV flights.

  11. 3D MRI of non-Gaussian (3)He gas diffusion in the rat lung.

    PubMed

    Jacob, Richard E; Laicher, Gernot; Minard, Kevin R

    2007-10-01

    In (3)He magnetic resonance images of pulmonary air spaces, the confining architecture of the parenchymal tissue results in a non-Gaussian distribution of signal phase that non-exponentially attenuates image intensity as diffusion weighting is increased. Here, two approaches previously used for the analysis of non-Gaussian effects in the lung are compared and related using diffusion-weighted (3)He MR images of mechanically ventilated rats. One approach is model-based and was presented by Yablonskiy et al., while the other approach utilizes the second order decay contribution that is predicted from the cumulant expansion theorem. Total lung coverage is achieved using a hybrid 3D pulse sequence that combines conventional phase encoding with sparse radial sampling for efficient gas usage. This enables the acquisition of nine 3D images using a total of only approximately 1 L of hyperpolarized (3)He gas. Diffusion weighting ranges from 0 s/cm(2) to 40 s/cm(2). Results show that the non-Gaussian effects of (3)He gas diffusion in healthy rat lungs are directly attributed to the anisotropic geometry of lung microstructure as predicted by the Yablonskiy model, and that quantitative analysis over the entire lung can be reliably repeated in time-course studies of the same animal.

  12. 3D MRI of non-Gaussian 3He gas diffusion in the rat lung

    NASA Astrophysics Data System (ADS)

    Jacob, Richard E.; Laicher, Gernot; Minard, Kevin R.

    2007-10-01

    In 3He magnetic resonance images of pulmonary air spaces, the confining architecture of the parenchymal tissue results in a non-Gaussian distribution of signal phase that non-exponentially attenuates image intensity as diffusion weighting is increased. Here, two approaches previously used for the analysis of non-Gaussian effects in the lung are compared and related using diffusion-weighted 3He MR images of mechanically ventilated rats. One approach is model-based and was presented by Yablonskiy et al., while the other approach utilizes the second order decay contribution that is predicted from the cumulant expansion theorem. Total lung coverage is achieved using a hybrid 3D pulse sequence that combines conventional phase encoding with sparse radial sampling for efficient gas usage. This enables the acquisition of nine 3D images using a total of only ˜1 L of hyperpolarized 3He gas. Diffusion weighting ranges from 0 s/cm 2 to 40 s/cm 2. Results show that the non-Gaussian effects of 3He gas diffusion in healthy rat lungs are directly attributed to the anisotropic geometry of lung microstructure as predicted by the Yablonskiy model, and that quantitative analysis over the entire lung can be reliably repeated in time-course studies of the same animal.

  13. Efficient 3D multi-region prostate MRI segmentation using dual optimization.

    PubMed

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    Efficient and accurate extraction of the prostate, in particular its clinically meaningful sub-regions from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, we propose a novel multi-region segmentation approach to simultaneously locating the boundaries of the prostate and its two major sub-regions: the central gland and the peripheral zone. The proposed method utilizes the prior knowledge of the spatial region consistency and employs a customized prostate appearance model to simultaneously segment multiple clinically meaningful regions. We solve the resulted challenging combinatorial optimization problem by means of convex relaxation, for which we introduce a novel spatially continuous flow-maximization model and demonstrate its duality to the investigated convex relaxed optimization problem with the region consistency constraint. Moreover, the proposed continuous max-flow model naturally leads to a new and efficient continuous max-flow based algorithm, which enjoys great advantages in numerics and can be readily implemented on GPUs. Experiments using 15 T2-weighted 3D prostate MR images, by inter- and intra-operator variability, demonstrate the promising performance of the proposed approach.

  14. 3-D measuring of engine camshaft based on machine vision

    NASA Astrophysics Data System (ADS)

    Qiu, Jianxin; Tan, Liang; Xu, Xiaodong

    2008-12-01

    The non-touch 3D measuring based on machine vision is introduced into camshaft precise measuring. Currently, because CCD 3-dimensional measuring can't meet requirements for camshaft's measuring precision, it's necessary to improve its measuring precision. In this paper, we put forward a method to improve the measuring method. A Multi-Character Match method based on the Polygonal Non-regular model is advanced with the theory of Corner Extraction and Corner Matching .This method has solved the problem of the matching difficulty and a low precision. In the measuring process, the use of the Coded marked Point method and Self-Character Match method can bring on this problem. The 3D measuring experiment on camshaft, which based on the Multi-Character Match method of the Polygonal Non-regular model, proves that the normal average measuring precision is increased to a new level less than 0.04mm in the point-clouds photo merge. This measuring method can effectively increase the 3D measuring precision of the binocular CCD.

  15. A discriminative model-constrained EM approach to 3D MRI brain tissue classification and intensity non-uniformity correction

    NASA Astrophysics Data System (ADS)

    Wels, Michael; Zheng, Yefeng; Huber, Martin; Hornegger, Joachim; Comaniciu, Dorin

    2011-06-01

    We describe a fully automated method for tissue classification, which is the segmentation into cerebral gray matter (GM), cerebral white matter (WM), and cerebral spinal fluid (CSF), and intensity non-uniformity (INU) correction in brain magnetic resonance imaging (MRI) volumes. It combines supervised MRI modality-specific discriminative modeling and unsupervised statistical expectation maximization (EM) segmentation into an integrated Bayesian framework. While both the parametric observation models and the non-parametrically modeled INUs are estimated via EM during segmentation itself, a Markov random field (MRF) prior model regularizes segmentation and parameter estimation. Firstly, the regularization takes into account knowledge about spatial and appearance-related homogeneity of segments in terms of pairwise clique potentials of adjacent voxels. Secondly and more importantly, patient-specific knowledge about the global spatial distribution of brain tissue is incorporated into the segmentation process via unary clique potentials. They are based on a strong discriminative model provided by a probabilistic boosting tree (PBT) for classifying image voxels. It relies on the surrounding context and alignment-based features derived from a probabilistic anatomical atlas. The context considered is encoded by 3D Haar-like features of reduced INU sensitivity. Alignment is carried out fully automatically by means of an affine registration algorithm minimizing cross-correlation. Both types of features do not immediately use the observed intensities provided by the MRI modality but instead rely on specifically transformed features, which are less sensitive to MRI artifacts. Detailed quantitative evaluations on standard phantom scans and standard real-world data show the accuracy and robustness of the proposed method. They also demonstrate relative superiority in comparison to other state-of-the-art approaches to this kind of computational task: our method achieves average

  16. Automated scoring of regional lung perfusion in children from contrast enhanced 3D MRI

    NASA Astrophysics Data System (ADS)

    Heimann, Tobias; Eichinger, Monika; Bauman, Grzegorz; Bischoff, Arved; Puderbach, Michael; Meinzer, Hans-Peter

    2012-03-01

    MRI perfusion images give information about regional lung function and can be used to detect pulmonary pathologies in cystic fibrosis (CF) children. However, manual assessment of the percentage of pathologic tissue in defined lung subvolumes features large inter- and intra-observer variation, making it difficult to determine disease progression consistently. We present an automated method to calculate a regional score for this purpose. First, lungs are located based on thresholding and morphological operations. Second, statistical shape models of left and right children's lungs are initialized at the determined locations and used to precisely segment morphological images. Segmentation results are transferred to perfusion maps and employed as masks to calculate perfusion statistics. An automated threshold to determine pathologic tissue is calculated and used to determine accurate regional scores. We evaluated the method on 10 MRI images and achieved an average surface distance of less than 1.5 mm compared to manual reference segmentations. Pathologic tissue was detected correctly in 9 cases. The approach seems suitable for detecting early signs of CF and monitoring response to therapy.

  17. Projection-slice theorem based 2D-3D registration

    NASA Astrophysics Data System (ADS)

    van der Bom, M. J.; Pluim, J. P. W.; Homan, R.; Timmer, J.; Bartels, L. W.

    2007-03-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's anatomy in the dimension along the projection axis. It would be very profitable to provide the surgeon or interventionalist with a 3D insight of the patient's anatomy that is directly linked to the X-ray images acquired during the procedure. In this paper we present a new robust 2D-3D registration method based on the Projection-Slice Theorem. This theorem gives us a relation between the pre-operative 3D data set and the interventional projection images. Registration is performed by minimizing a translation invariant similarity measure that is applied to the Fourier transforms of the images. The method was tested by performing multiple exhaustive searches on phantom data of the Circle of Willis and on a post-mortem human skull. Validation was performed visually by comparing the test projections to the ones that corresponded to the minimal value of the similarity measure. The Projection-Slice Theorem Based method was shown to be very effective and robust, and provides capture ranges up to 62 degrees. Experiments have shown that the method is capable of retrieving similar results when translations are applied to the projection images.

  18. Event-based 3D reconstruction from neuromorphic retinas.

    PubMed

    Carneiro, João; Ieng, Sio-Hoi; Posch, Christoph; Benosman, Ryad

    2013-09-01

    This paper presents a novel N-ocular 3D reconstruction algorithm for event-based vision data from bio-inspired artificial retina sensors. Artificial retinas capture visual information asynchronously and encode it into streams of asynchronous spike-like pulse signals carrying information on, e.g., temporal contrast events in the scene. The precise time of the occurrence of these visual features are implicitly encoded in the spike timings. Due to the high temporal resolution of the asynchronous visual information acquisition, the output of these sensors is ideally suited for dynamic 3D reconstruction. The presented technique takes full benefit of the event-driven operation, i.e. events are processed individually at the moment they arrive. This strategy allows us to preserve the original dynamics of the scene, hence allowing for more robust 3D reconstructions. As opposed to existing techniques, this algorithm is based on geometric and time constraints alone, making it particularly simple to implement and largely linear. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    SciTech Connect

    Yang, Y. X.; Van Reeth, E.; Poh, C. L.; Teo, S.-K.; Tan, C. H.; Tham, I. W. K.

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  20. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion.

    PubMed

    Yang, Y X; Teo, S-K; Van Reeth, E; Tan, C H; Tham, I W K; Poh, C L

    2015-08-01

    Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors' proposed approach. A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors' proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  1. 3D shape measurement with phase correlation based fringe projection

    NASA Astrophysics Data System (ADS)

    Kühmstedt, Peter; Munckelt, Christoph; Heinze, Matthias; Bräuer-Burchardt, Christian; Notni, Gunther

    2007-06-01

    Here we propose a method for 3D shape measurement by means of phase correlation based fringe projection in a stereo arrangement. The novelty in the approach is characterized by following features. Correlation between phase values of the images of two cameras is used for the co-ordinate calculation. This work stands in contrast to the sole usage of phase values (phasogrammetry) or classical triangulation (phase values and image co-ordinates - camera raster values) for the determination of the co-ordinates. The method's main advantage is the insensitivity of the 3D-coordinates from the absolute phase values. Thus it prevents errors in the determination of the co-ordinates and improves robustness in areas with interreflections artefacts and inhomogeneous regions of intensity. A technical advantage is the fact that the accuracy of the 3D co-ordinates does not depend on the projection resolution. Thus the achievable quality of the 3D co-ordinates can be selectively improved by the use of high quality camera lenses and can participate in improvements in modern camera technologies. The presented new solution of the stereo based fringe projection with phase correlation makes a flexible, errortolerant realization of measuring systems within different applications like quality control, rapid prototyping, design and CAD/CAM possible. In the paper the phase correlation method will be described in detail. Furthermore, different realizations will be shown, i.e. a mobile system for the measurement of large objects and an endoscopic like system for CAD/CAM in dental industry.

  2. Abdominal aortic aneurysm imaging with 3-D ultrasound: 3-D-based maximum diameter measurement and volume quantification.

    PubMed

    Long, A; Rouet, L; Debreuve, A; Ardon, R; Barbe, C; Becquemin, J P; Allaire, E

    2013-08-01

    The clinical reliability of 3-D ultrasound imaging (3-DUS) in quantification of abdominal aortic aneurysm (AAA) was evaluated. B-mode and 3-DUS images of AAAs were acquired for 42 patients. AAAs were segmented. A 3-D-based maximum diameter (Max3-D) and partial volume (Vol30) were defined and quantified. Comparisons between 2-D (Max2-D) and 3-D diameters and between orthogonal acquisitions were performed. Intra- and inter-observer reproducibility was evaluated. Intra- and inter-observer coefficients of repeatability (CRs) were less than 5.18 mm for Max3-D. Intra-observer and inter-observer CRs were respectively less than 6.16 and 8.71 mL for Vol30. The mean of normalized errors of Vol30 was around 7%. Correlation between Max2-D and Max3-D was 0.988 (p < 0.0001). Max3-D and Vol30 were not influenced by a probe rotation of 90°. Use of 3-DUS to quantify AAA is a new approach in clinical practice. The present study proposed and evaluated dedicated parameters. Their reproducibility makes the technique clinically reliable.

  3. Highly-accelerated self-gated free-breathing 3D cardiac cine MRI: validation in assessment of left ventricular function.

    PubMed

    Liu, Jing; Feng, Li; Shen, Hsin-Wei; Zhu, Chengcheng; Wang, Yan; Mukai, Kanae; Brooks, Gabriel C; Ordovas, Karen; Saloner, David

    2017-08-01

    This work presents a highly-accelerated, self-gated, free-breathing 3D cardiac cine MRI method for cardiac function assessment. A golden-ratio profile based variable-density, pseudo-random, Cartesian undersampling scheme was implemented for continuous 3D data acquisition. Respiratory self-gating was achieved by deriving motion signal from the acquired MRI data. A multi-coil compressed sensing technique was employed to reconstruct 4D images (3D+time). 3D cardiac cine imaging with self-gating was compared to bellows gating and the clinical standard breath-held 2D cine imaging for evaluation of self-gating accuracy, image quality, and cardiac function in eight volunteers. Reproducibility of 3D imaging was assessed. Self-gated 3D imaging provided an image quality score of 3.4 ± 0.7 vs 4.0 ± 0 with the 2D method (p = 0.06). It determined left ventricular end-systolic volume as 42.4 ± 11.5 mL, end-diastolic volume as 111.1 ± 24.7 mL, and ejection fraction as 62.0 ± 3.1%, which were comparable to the 2D method, with bias ± 1.96 × SD of -0.8 ± 7.5 mL (p = 0.90), 2.6 ± 3.3 mL (p = 0.84) and 1.4 ± 6.4% (p = 0.45), respectively. The proposed 3D cardiac cine imaging method enables reliable respiratory self-gating performance with good reproducibility, and provides comparable image quality and functional measurements to 2D imaging, suggesting that self-gated, free-breathing 3D cardiac cine MRI framework is promising for improved patient comfort and cardiac MRI scan efficiency.

  4. Improved l1-SPIRiT using 3D walsh transform-based sparsity basis.

    PubMed

    Feng, Zhen; Liu, Feng; Jiang, Mingfeng; Crozier, Stuart; Guo, He; Wang, Yuxin

    2014-09-01

    l1-SPIRiT is a fast magnetic resonance imaging (MRI) method which combines parallel imaging (PI) with compressed sensing (CS) by performing a joint l1-norm and l2-norm optimization procedure. The original l1-SPIRiT method uses two-dimensional (2D) Wavelet transform to exploit the intra-coil data redundancies and a joint sparsity model to exploit the inter-coil data redundancies. In this work, we propose to stack all the coil images into a three-dimensional (3D) matrix, and then a novel 3D Walsh transform-based sparsity basis is applied to simultaneously reduce the intra-coil and inter-coil data redundancies. Both the 2D Wavelet transform-based and the proposed 3D Walsh transform-based sparsity bases were investigated in the l1-SPIRiT method. The experimental results show that the proposed 3D Walsh transform-based l1-SPIRiT method outperformed the original l1-SPIRiT in terms of image quality and computational efficiency.

  5. A flexible fast 3D profilometry based on modulation measurement

    NASA Astrophysics Data System (ADS)

    Dou, Yunfu; Su, Xianyu; Chen, Yanfei; Wang, Ying

    2011-03-01

    This paper proposes a flexible fast profilometry based on modulation measurement. Two orthogonal gratings through a beam splitter are vertically projected on an object surface, and the measured object is placed between the imaging planes of the two gratings. Then the image of the object surface modulated by the orthogonal gratings can be obtained by a CCD camera in the same direction as the grating projection. This image is processed by the operations consisting of performing the Fourier transform, spatial frequency filtering and inverse Fourier transform. Using the modulation distributions of two grating patterns, we can reconstruct the 3D shape of the object. In the measurement process, we only need to capture one fringe pattern, so it is faster than the MMP and remains the advantages of it. In the article, the principle of this method, the setup of the measurement system, some simulations and primary experiment results are given. The simulative and experimental result proves it can restore the 3D shape of the complex object fast and comparatively accurate. Because only one fringe pattern is needed in the testing, our method has a promising extensive application prospect in real-time acquiring and dynamic measurement of 3D data of complex objects.

  6. Neuromorphic Event-Based 3D Pose Estimation

    PubMed Central

    Reverter Valeiras, David; Orchard, Garrick; Ieng, Sio-Hoi; Benosman, Ryad B.

    2016-01-01

    Pose estimation is a fundamental step in many artificial vision tasks. It consists of estimating the 3D pose of an object with respect to a camera from the object's 2D projection. Current state of the art implementations operate on images. These implementations are computationally expensive, especially for real-time applications. Scenes with fast dynamics exceeding 30–60 Hz can rarely be processed in real-time using conventional hardware. This paper presents a new method for event-based 3D object pose estimation, making full use of the high temporal resolution (1 μs) of asynchronous visual events output from a single neuromorphic camera. Given an initial estimate of the pose, each incoming event is used to update the pose by combining both 3D and 2D criteria. We show that the asynchronous high temporal resolution of the neuromorphic camera allows us to solve the problem in an incremental manner, achieving real-time performance at an update rate of several hundreds kHz on a conventional laptop. We show that the high temporal resolution of neuromorphic cameras is a key feature for performing accurate pose estimation. Experiments are provided showing the performance of the algorithm on real data, including fast moving objects, occlusions, and cases where the neuromorphic camera and the object are both in motion. PMID:26834547

  7. An endoscopic 3D scanner based on structured light.

    PubMed

    Schmalz, Christoph; Forster, Frank; Schick, Anton; Angelopoulou, Elli

    2012-07-01

    We present a new endoscopic 3D scanning system based on Single Shot Structured Light. The proposed design makes it possible to build an extremely small scanner. The sensor head contains a catadioptric camera and a pattern projection unit. The paper describes the working principle and calibration procedure of the sensor. The prototype sensor head has a diameter of only 3.6mm and a length of 14mm. It is mounted on a flexible shaft. The scanner is designed for tubular cavities and has a cylindrical working volume of about 30mm length and 30mm diameter. It acquires 3D video at 30 frames per second and typically generates approximately 5000 3D points per frame. By design, the resolution varies over the working volume, but is generally better than 200μm. A prototype scanner has been built and is evaluated in experiments with phantoms and biological samples. The recorded average error on a known test object was 92μm.

  8. Interpolation of 3-D binary images based on morphological skeletonization.

    PubMed

    Chatzis, V; Pitas, I

    2000-07-01

    In this paper, the morphological skeleton interpolation (MSI) algorithm is presented. It is an efficient, shape-based interpolation method used for interpolating slices in a three-dimensional (3-D) binary object. It is based on morphological skeletonization, which is used for two-dimensional (2-D) slice representation. The proposed morphological skeleton matching process provides translation, rotation, and scaling information at the same time. The interpolated slices preserve the shape of the original object slices, when the slices have similar shapes. It can also modify the shape of an object when the successive slices do not have similar shapes. Applications on artificial and real data are also presented.

  9. Facial-paralysis diagnostic system based on 3D reconstruction

    NASA Astrophysics Data System (ADS)

    Khairunnisaa, Aida; Basah, Shafriza Nisha; Yazid, Haniza; Basri, Hassrizal Hassan; Yaacob, Sazali; Chin, Lim Chee

    2015-05-01

    The diagnostic process of facial paralysis requires qualitative assessment for the classification and treatment planning. This result is inconsistent assessment that potential affect treatment planning. We developed a facial-paralysis diagnostic system based on 3D reconstruction of RGB and depth data using a standard structured-light camera - Kinect 360 - and implementation of Active Appearance Models (AAM). We also proposed a quantitative assessment for facial paralysis based on triangular model. In this paper, we report on the design and development process, including preliminary experimental results. Our preliminary experimental results demonstrate the feasibility of our quantitative assessment system to diagnose facial paralysis.

  10. Prospective trial of breast MRI versus 2D and 3D ultrasound for evaluation of response to neoadjuvant chemotherapy.

    PubMed

    Lee, Marie Catherine; Gonzalez, Segundo Jaime; Lin, Huiyi; Zhao, Xiuhua; Kiluk, John V; Laronga, Christine; Mooney, Blaise

    2015-09-01

    Preoperative imaging to assess response to neoadjuvant chemotherapy in breast cancer is routine but no single imaging modality is standard of practice. Our hypothesis is that ultrasound (US) is comparable to magnetic resonance imaging (MRI) in the prediction of residual disease. A single-institution, Institutional Review Board-approved prospective trial of primary invasive ductal breast cancer patients receiving neoadjuvant chemotherapy enrolled women from 2008 to 2012. Two-dimensional (2D) and three-dimensional (3D) US, as well as MRI images of pre- and post-neoadjuvant tumors were obtained. Skin involvement or inadequate images were excluded. Residual tumor on imaging was compared with surgical pathology. Differences of tumor volume on imaging and pathology were compared using the non-parametric Wilcoxon signed-rank test. US to MRI agreement was determined by the kappa coefficient. Tumor volumes in estrogen receptor (ER), progesterone receptor (PR), and Her2neu subgroups were compared using the Kruskal-Wallis test. ER/PR staining <5 % was considered negative; Her2neu status was determined by in situ hybridization. Forty-two patients were enrolled in the study; 39 had evaluable post-treatment data. Four patients were Her2neu positive, and 17 (46 %) patients had triple-negative tumors. Among 11 (28 %) patients with pathologic complete response (pCR), US correctly predicted pCR in six (54.5 %) patients compared with eight (72.7 %) patients when MRI was used. This is a substantial agreement between US and MRI in predicting pCR (kappa = 0.62). There was no difference between 2D and 3D US modalities. For the 39 patients, US and MRI had no significant difference in volume estimation of pathology, even stratified by receptor status. The estimation of residual breast tumor volume by US and MRI achieves similar results, including prediction of pCR.

  11. Surface topography study of prepared 3D printed moulds via 3D printer for silicone elastomer based nasal prosthesis

    NASA Astrophysics Data System (ADS)

    Abdullah, Abdul Manaf; Din, Tengku Noor Daimah Tengku; Mohamad, Dasmawati; Rahim, Tuan Noraihan Azila Tuan; Akil, Hazizan Md; Rajion, Zainul Ahmad

    2016-12-01

    Conventional prosthesis fabrication is highly depends on the hand creativity of laboratory technologist. The development in 3D printing technology offers a great help in fabricating affordable and fast yet esthetically acceptable prostheses. This study was conducted to discover the potential of 3D printed moulds for indirect silicone elastomer based nasal prosthesis fabrication. Moulds were designed using computer aided design (CAD) software (Solidworks, USA) and converted into the standard tessellation language (STL) file. Three moulds with layer thickness of 0.1, 0.2 and 0.3mm were printed utilizing polymer filament based 3D printer (Makerbot Replicator 2X, Makerbot, USA). Another one mould was printed utilizing liquid resin based 3D printer (Objet 30 Scholar, Stratasys, USA) as control. The printed moulds were then used to fabricate maxillofacial silicone specimens (n=10)/mould. Surface profilometer (Surfcom Flex, Accretech, Japan), digital microscope (KH77000, Hirox, USA) and scanning electron microscope (Quanta FEG 450, Fei, USA) were used to measure the surface roughness as well as the topological properties of fabricated silicone. Statistical analysis of One-Way ANOVA was employed to compare the surface roughness of the fabricated silicone elastomer. Result obtained demonstrated significant differences in surface roughness of the fabricated silicone (p<0.01). Further post hoc analysis also revealed significant differences in silicone fabricated using different 3D printed moulds (p<0.01). A 3D printed mould was successfully prepared and characterized. With surface topography that could be enhanced, inexpensive and rapid mould fabrication techniques, polymer filament based 3D printer is potential for indirect silicone elastomer based nasal prosthesis fabrication.

  12. Modeling approaches for ligand-based 3D similarity.

    PubMed

    Tresadern, Gary; Bemporad, Daniele

    2010-10-01

    3D ligand-based similarity approaches are widely used in the early phases of drug discovery for tasks such as hit finding by virtual screening or compound design with quantitative structure-activity relationships. Here in we review widely used software for performing such tasks. Some techniques are based on relatively mature technology, shape-based similarity for instance. Typically, these methods remained in the realm of the expert user, the experienced modeler. However, advances in implementation and speed have improved usability and allow these methods to be applied to databases comprising millions of compounds. There are now many reports of such methods impacting drug-discovery projects. As such, the medicinal chemistry community has become the intended market for some of these new tools, yet they may consider the wide array and choice of approaches somewhat disconcerting. Each method has subtle differences and is better suited to certain tasks than others. In this article we review some of the widely used computational methods via application, provide straightforward background on the underlying theory and provide examples for the interested reader to pursue in more detail. In the new era of preclinical drug discovery there will be ever more pressure to move faster and more efficiently, and computational approaches based on 3D ligand similarity will play an increasing role in in this process.

  13. Virtual reality 3D headset based on DMD light modulators

    SciTech Connect

    Bernacki, Bruce E.; Evans, Allan; Tang, Edward

    2014-06-13

    We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micro-mirror devices (DMD). Our approach leverages silicon micro mirrors offering 720p resolution displays in a small form-factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high resolution and low power consumption. Applications include night driving, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design is described in which light from the DMD is imaged to infinity and the user’s own eye lens forms a real image on the user’s retina.

  14. Fast vision-based catheter 3D reconstruction.

    PubMed

    Moradi Dalvand, Mohsen; Nahavandi, Saeid; Howe, Robert D

    2016-07-21

    Continuum robots offer better maneuverability and inherent compliance and are well-suited for surgical applications as catheters, where gentle interaction with the environment is desired. However, sensing their shape and tip position is a challenge as traditional sensors can not be employed in the way they are in rigid robotic manipulators. In this paper, a high speed vision-based shape sensing algorithm for real-time 3D reconstruction of continuum robots based on the views of two arbitrary positioned cameras is presented. The algorithm is based on the closed-form analytical solution of the reconstruction of quadratic curves in 3D space from two arbitrary perspective projections. High-speed image processing algorithms are developed for the segmentation and feature extraction from the images. The proposed algorithms are experimentally validated for accuracy by measuring the tip position, length and bending and orientation angles for known circular and elliptical catheter shaped tubes. Sensitivity analysis is also carried out to evaluate the robustness of the algorithm. Experimental results demonstrate good accuracy (maximum errors of  ±0.6 mm and  ±0.5 deg), performance (200 Hz), and robustness (maximum absolute error of 1.74 mm, 3.64 deg for the added noises) of the proposed high speed algorithms.

  15. Fast vision-based catheter 3D reconstruction

    NASA Astrophysics Data System (ADS)

    Moradi Dalvand, Mohsen; Nahavandi, Saeid; Howe, Robert D.

    2016-07-01

    Continuum robots offer better maneuverability and inherent compliance and are well-suited for surgical applications as catheters, where gentle interaction with the environment is desired. However, sensing their shape and tip position is a challenge as traditional sensors can not be employed in the way they are in rigid robotic manipulators. In this paper, a high speed vision-based shape sensing algorithm for real-time 3D reconstruction of continuum robots based on the views of two arbitrary positioned cameras is presented. The algorithm is based on the closed-form analytical solution of the reconstruction of quadratic curves in 3D space from two arbitrary perspective projections. High-speed image processing algorithms are developed for the segmentation and feature extraction from the images. The proposed algorithms are experimentally validated for accuracy by measuring the tip position, length and bending and orientation angles for known circular and elliptical catheter shaped tubes. Sensitivity analysis is also carried out to evaluate the robustness of the algorithm. Experimental results demonstrate good accuracy (maximum errors of  ±0.6 mm and  ±0.5 deg), performance (200 Hz), and robustness (maximum absolute error of 1.74 mm, 3.64 deg for the added noises) of the proposed high speed algorithms.

  16. Computer-aided diagnosis of mass-like lesion in breast MRI: differential analysis of the 3-D morphology between benign and malignant tumors.

    PubMed

    Huang, Yan-Hao; Chang, Yeun-Chung; Huang, Chiun-Sheng; Wu, Tsung-Ju; Chen, Jeon-Hor; Chang, Ruey-Feng

    2013-12-01

    This study aimed to evaluate the value of using 3-D breast MRI morphologic features to differentiate benign and malignant breast lesions. The 3-D morphological features extracted from breast MRI were used to analyze the malignant likelihood of tumor from ninety-five solid breast masses (44 benign and 51 malignant) of 82 patients. Each mass-like lesion was examined with regards to three categories of morphologic features, including texture-based gray-level co-occurrence matrix (GLCM) feature, shape, and ellipsoid fitting features. For obtaining a robust combination of features from different categories, the biserial correlation coefficient (|r(pb)|)≧0.4 was used as the feature selection criterion. Receiver operating characteristic (ROC) curve was used to evaluate performance and Student's t-test to verify the classification accuracy. The combination of the selected 3-D morphological features, including conventional compactness, radius, spiculation, surface ratio, volume covering ratio, number of inside angular regions, sum of number of inside and outside angular regions, showed an accuracy of 88.42% (84/95), sensitivity of 88.24% (45/51), and specificity of 88.64% (39/44), respectively. The AZ value was 0.8926 for these seven combined morphological features. In conclusion, 3-D MR morphological features specified by GLCM, tumor shape and ellipsoid fitting were useful for differentiating benign and malignant breast masses.

  17. Estimation of Pulmonary Motion in Healthy Subjects and Patients with Intrathoracic Tumors Using 3D-Dynamic MRI: Initial Results

    PubMed Central

    Schoebinger, Max; Herth, Felix; Tuengerthal, Siegfried; Meinzer, Heinz-Peter; Kauczor, Hans-Ulrich

    2009-01-01

    Objective To estimate a new technique for quantifying regional lung motion using 3D-MRI in healthy volunteers and to apply the technique in patients with intra- or extrapulmonary tumors. Materials and Methods Intraparenchymal lung motion during a whole breathing cycle was quantified in 30 healthy volunteers using 3D-dynamic MRI (FLASH [fast low angle shot] 3D, TRICKS [time-resolved interpolated contrast kinetics]). Qualitative and quantitative vector color maps and cumulative histograms were performed using an introduced semiautomatic algorithm. An analysis of lung motion was performed and correlated with an established 2D-MRI technique for verification. As a proof of concept, the technique was applied in five patients with non-small cell lung cancer (NSCLC) and 5 patients with malignant pleural mesothelioma (MPM). Results The correlation between intraparenchymal lung motion of the basal lung parts and the 2D-MRI technique was significant (r = 0.89, p < 0.05). Also, the vector color maps quantitatively illustrated regional lung motion in all healthy volunteers. No differences were observed between both hemithoraces, which was verified by cumulative histograms. The patients with NSCLC showed a local lack of lung motion in the area of the tumor. In the patients with MPM, there was global diminished motion of the tumor bearing hemithorax, which improved siginificantly after chemotherapy (CHT) (assessed by the 2D- and 3D-techniques) (p < 0.01). Using global spirometry, an improvement could also be shown (vital capacity 2.9 ± 0.5 versus 3.4 L ± 0.6, FEV1 0.9 ± 0.2 versus 1.4 ± 0.2 L) after CHT, but this improvement was not significant. Conclusion A 3D-dynamic MRI is able to quantify intraparenchymal lung motion. Local and global parenchymal pathologies can be precisely located and might be a new tool used to quantify even slight changes in lung motion (e.g. in therapy monitoring, follow-up studies or even benign lung diseases). PMID:19885311

  18. New opportunities for quantitative and time efficient 3D MRI of liquid and solid electrochemical cell components: Sectoral Fast Spin Echo and SPRITE.

    PubMed

    Romanenko, Konstantin; Forsyth, Maria; O'Dell, Luke A

    2014-11-01

    The ability to image electrochemical processes in situ using nuclear magnetic resonance imaging (MRI) offers exciting possibilities for understanding and optimizing materials in batteries, fuel cells and supercapacitors. In these applications, however, the quality of the MRI measurement is inherently limited by the presence of conductive elements in the cell or device. To overcome related difficulties, optimal methodologies have to be employed. We show that time-efficient three dimensional (3D) imaging of liquid and solid lithium battery components can be performed by Sectoral Fast Spin Echo and Single Point Imaging with T1 Enhancement (SPRITE), respectively. The former method is based on the generalized phase encoding concept employed in clinical MRI, which we have adapted and optimized for materials science and electrochemistry applications. Hard radio frequency pulses, short echo spacing and centrically ordered sectoral phase encoding ensure accurate and time-efficient full volume imaging. Mapping of density, diffusivity and relaxation time constants in metal-containing liquid electrolytes is demonstrated. 1, 2 and 3D SPRITE approaches show strong potential for rapid high resolution (7)Li MRI of lithium electrode components. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Integral imaging based 3D display of holographic data.

    PubMed

    Yöntem, Ali Özgür; Onural, Levent

    2012-10-22

    We propose a method and present applications of this method that converts a diffraction pattern into an elemental image set in order to display them on an integral imaging based display setup. We generate elemental images based on diffraction calculations as an alternative to commonly used ray tracing methods. Ray tracing methods do not accommodate the interference and diffraction phenomena. Our proposed method enables us to obtain elemental images from a holographic recording of a 3D object/scene. The diffraction pattern can be either numerically generated data or digitally acquired optical data. The method shows the connection between a hologram (diffraction pattern) and an elemental image set of the same 3D object. We showed three examples, one of which is the digitally captured optical diffraction tomography data of an epithelium cell. We obtained optical reconstructions with our integral imaging display setup where we used a digital lenslet array. We also obtained numerical reconstructions, again by using the diffraction calculations, for comparison. The digital and optical reconstruction results are in good agreement.

  20. EEG-based usability assessment of 3D shutter glasses.

    PubMed

    Wenzel, Markus A; Schultze-Kraft, Rafael; Meinecke, Frank C; Fabien Cardinaux; Kemp, Thomas; Klaus-Robert Müller; Gabriel Curio; Benjamin Blankertz

    2016-02-01

    Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the 'neural flicker' vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Effects of the shutter glasses were traced in the EEG up to around 67 Hz-about 20 Hz over the flicker perception threshold-and vanished at the subsequent frequency level of 77 Hz. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  1. EEG-based usability assessment of 3D shutter glasses

    NASA Astrophysics Data System (ADS)

    Wenzel, Markus A.; Schultze-Kraft, Rafael; Meinecke, Frank C.; Cardinaux, Fabien; Kemp, Thomas; Müller, Klaus-Robert; Curio, Gabriel; Blankertz, Benjamin

    2016-02-01

    Objective. Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the ‘neural flicker’ vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Approach. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Main Result. Effects of the shutter glasses were traced in the EEG up to around 67 Hz—about 20 Hz over the flicker perception threshold—and vanished at the subsequent frequency level of 77 Hz. Significance. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.

  2. SU-E-J-231: Comparison of 3D Angiogram and MRI in Delineating the AVM Target for Frameless Stereotactic Radiosurgery

    SciTech Connect

    Avkshtol, V; Tanny, S; Reddy, K; Chen, C; Parsai, E

    2014-06-01

    Purpose: Stereotactic radiation therapy (SRT) provides an excellent alternative to embolization and surgical excision for the management of appropriately selected cerebral arteriovenous malformations (AVMs). The currently accepted standard for delineating AVMs is planar digital subtraction angiography (DSA). DSA can be used to acquire a 3D data set that preserves osseous structures (3D-DA) at the time of the angiography for SRT planning. Magnetic resonance imaging (MRI) provides an alternative noninvasive method of visualizing the AVM nidus with comparable spatial resolution. We utilized 3D-DA and T1 post-contrast MRI data to evaluate the differences in SRT target volumes. Methods: Four patients underwent 3D-DA and high-resolution MRI. 3D T1 post-contrast images were obtained in all three reconstruction planes. A planning CT was fused with MRI and 3D-DA data sets. The AVMs were contoured utilizing one of the image sets at a time. Target volume, centroid, and maximum and minimum dimensions were analyzed for each patient. Results: Targets delineated using post-contrast MRI demonstrated a larger mean volume. AVMs >2 cc were found to have a larger difference between MRI and 3D-DA volumes. Larger AVMs also demonstrated a smaller relative uncertainty in contour centroid position (1 mm). AVM targets <2 cc had smaller absolute differences in volume, but larger differences in contour centroid position (2.5 mm). MRI targets demonstrated a more irregular shape compared to 3D-DA targets. Conclusions: Our preliminary data supports the use of MRI alone to delineate AVM targets >2 cc. The greater centroid stability for AVMs >2 cc ensures accurate target localization during image fusion. The larger MRI target volumes did not result in prohibitively greater volumes of normal brain tissue receiving the prescription dose. The larger centroid instability for AVMs <2 cc precludes the use of MRI alone for target delineation. We recommend incorporating a 3D-DA for these patients.

  3. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons.

    PubMed

    Kalia, Vivek; Fritz, Benjamin; Johnson, Rory; Gilson, Wesley D; Raithel, Esther; Fritz, Jan

    2017-09-01

    To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. • High-resolution 3D TSE MRI improves visualization of ankle structures. • Limitations of current 3D TSE MRI include long scan times. • 3D CAIPIRINHA SPACE allows now a fourfold-accelerated data acquisition. • 3D CAIPIRINHA SPACE enables high-spatial-resolution ankle MRI within 10 min. • 10-min 3D CAIPIRINHA SPACE produces equal-or-better quality than 20-min 2D TSE.

  4. 3D morphology of the rear foot from MRI data: technical validation and clinical description

    NASA Astrophysics Data System (ADS)

    Stindel, Eric; Udupa, Jayaram K.; Hirsch, Bruce E.; Odhner, Dewey; Couture, Christine

    1998-06-01

    The purpose of this work is to characterize the 3D morphology of the bones of the rear foot using MR data. This work has two subaims: (1) to study the variability of the various computed architectural measures as a result of the subjectivity and variations in the various processing operations; (2) to study the morphology of the bones included in the peritalar complex. Each image data set utilized in this study consists of 60 longitudinal slices of the foot acquired on a 1.5 T commercial GE MR system. Our description of the rear foot morphology is based mainly on the principal axes, which represent the inertia axes of the bones, as well as on the bone surfaces. We use the live-wire method for segmenting and forming the surfaces of the bones. In the first part of this work, we focus on the dependence of the principal axes system on segmentation and on scan orientation. In the second part, we describe the normal morphology of the rear foot considering the four bones (calcaneus, cuboid, navicular, talus) and compare them to a population from the Upper Pleistocene. We conclude that this non-invasive method can be used in live patients to characterize the bone morphology or as a comparative method to classify population of bones. in spite of the variations involved in the various processing operations.

  5. Spatial consistency in 3D tract-based clustering statistics.

    PubMed

    Caan, Matthan W A; van Vliet, Lucas J; Majoie, Charles B L M; Aukema, Eline J; Grimbergen, C A; Vos, Frans M

    2008-01-01

    We propose a novel technique for tract-based comparison of DTI-indices between groups, based on a representation that is estimated while matching fiber tracts. The method involves a non-rigid registration based on a joint clustering and matching approach, after which a 3D-atlas of cluster center points is used as a frame of reference for statistics. Patient and control FA-distributions are compared per cluster. Spatial consistency is taken to reflect a significant difference between groups. Accordingly, a non-parametric classification is performed to assess the continuity of pathology over larger tract regions. In a study to infant survivors treated for medulloblastoma with intravenous methotrexate and cranial radiotherapy, significant decreases in FA in major parts of the corpus callosum were found.

  6. Triangulation Based 3D Laser Imaging for Fracture Orientation Analysis

    NASA Astrophysics Data System (ADS)

    Mah, J.; Claire, S.; Steve, M.

    2009-05-01

    Laser imaging has recently been identified as a potential tool for rock mass characterization. This contribution focuses on the application of triangulation based, short-range laser imaging to determine fracture orientation and surface texture. This technology measures the distance to the target by triangulating the projected and reflected laser beams, and also records the reflection intensity. In this study, we acquired 3D laser images of rock faces using the Laser Camera System (LCS), a portable instrument developed by Neptec Design Group (Ottawa, Canada). The LCS uses an infrared laser beam and is immune to the lighting conditions. The maximum image resolution is 1024 x 1024 volumetric image elements. Depth resolution is 0.5 mm at 5 m. An above ground field trial was conducted at a blocky road cut with well defined joint sets (Kingston, Ontario). An underground field trial was conducted at the Inco 175 Ore body (Sudbury, Ontario) where images were acquired in the dark and the joint set features were more subtle. At each site, from a distance of 3 m away from the rock face, a grid of six images (approximately 1.6 m by 1.6 m) was acquired at maximum resolution with 20% overlap between adjacent images. This corresponds to a density of 40 image elements per square centimeter. Polyworks, a high density 3D visualization software tool, was used to align and merge the images into a single digital triangular mesh. The conventional method of determining fracture orientations is by manual measurement using a compass. In order to be accepted as a substitute for this method, the LCS should be capable of performing at least to the capabilities of manual measurements. To compare fracture orientation estimates derived from the 3D laser images to manual measurements, 160 inclinometer readings were taken at the above ground site. Three prominent joint sets (strike/dip: 236/09, 321/89, 325/01) were identified by plotting the joint poles on a stereonet. Underground, two main joint

  7. A graph theoretic approach for computing 3D+time biventricular cardiac strain from tagged MRI data.

    PubMed

    Li, Ming; Gupta, Himanshu; Lloyd, Steven G; Dell'Italia, Louis J; Denney, Thomas S

    2017-01-01

    Tagged magnetic resonance imaging (tMRI) is a well-established method for evaluating regional mechanical function of the heart. Many techniques have been developed to compute 2D or 3D cardiac deformation and strain from tMRI images. In this paper, we present a new method for measuring 3D plus time biventricular myocardial strain from tMRI data. The method is composed of two parts. First, we use a Gabor filter bank to extract tag points along tag lines. Second, each tag point is classified to one of a set of indexed reference tag lines using a point classification with graph cuts (PCGC) algorithm and a motion compensation technique. 3D biventricular deformation and strain is computed at each image time frame from the classified tag points using a previously published finite difference method. The strain computation is fully automatic after myocardial contours are defined near end-diastole and end-systole. An in-vivo dataset composed of 30 human imaging studies with a range of pathologies was used for validation. Strains computed with the PCGC method with no manual corrections were compared to strains computed from both manually placed tag points and a manually-corrected unwrapped phase method. A typical cardiac imaging study with 10 short-axis slices and 6 long-axis slices required 30 min for contouring followed by 44 min of automated processing. The results demonstrate that the proposed method can reconstruct accurate 3D plus time cardiac strain maps with minimal user intervention.

  8. Segmentation and quantitative evaluation of brain MRI data with a multiphase 3D implicit deformable model

    NASA Astrophysics Data System (ADS)

    Angelini, Elsa D.; Song, Ting; Mensh, Brett D.; Laine, Andrew

    2004-05-01

    Segmentation of three-dimensional anatomical brain images into tissue classes has applications in both clinical and research settings. This paper presents the implementation and quantitative evaluation of a four-phase three-dimensional active contour implemented with a level set framework for automated segmentation of brain MRIs. The segmentation algorithm performs an optimal partitioning of three-dimensional data based on homogeneity measures that naturally evolves to the extraction of different tissue types in the brain. Random seed initialization was used to speed up numerical computation and avoid the need for a priori information. This random initialization ensures robustness of the method to variation of user expertise, biased a priori information and errors in input information that could be influenced by variations in image quality. Experimentation on three MRI brain data sets showed that an optimal partitioning successfully labeled regions that accurately identified white matter, gray matter and cerebrospinal fluid in the ventricles. Quantitative evaluation of the segmentation was performed with comparison to manually labeled data and computed false positive and false negative assignments of voxels for the three organs. We report high accuracy for the two comparison cases. These results demonstrate the efficiency and flexibility of this segmentation framework to perform the challenging task of automatically extracting brain tissue volume contours.

  9. CAD-based 3D object representation for robot vision

    SciTech Connect

    Bhanu, B.; Ho, C.C.

    1987-08-01

    This article explains that most existing vision systems rely on models generated in an ad hoc manner and have no explicit relation to the CAD/CAM system originally used to design and manufacture these objects. The authors desire a more unified system that allows vision models to be automatically generated from an existing CAD database. A CAD system contains an interactive design interface, graphic display utilities, model analysis tools, automatic manufacturing interfaces, etc. Although it is a suitable environment for design purposes, its representations and the models it generates do not contain all the features that are important in robot vision applications. In this article, the authors propose a CAD-based approach for building representations and models that can be used in diverse applications involving 3D object recognition and manipulation. There are two main steps in using this approach. First, they design the object's geometry using a CAD system, or extract its CAD model from the existing database if it has already been modeled. Second, they develop representations from the CAD model and construct features possibly by combining multiple representations that are crucial in 3D object recognition and manipulation.

  10. Ultra-realistic 3-D imaging based on colour holography

    NASA Astrophysics Data System (ADS)

    Bjelkhagen, H. I.

    2013-02-01

    A review of recent progress in colour holography is provided with new applications. Colour holography recording techniques in silver-halide emulsions are discussed. Both analogue, mainly Denisyuk colour holograms, and digitally-printed colour holograms are described and their recent improvements. An alternative to silver-halide materials are the panchromatic photopolymer materials such as the DuPont and Bayer photopolymers which are covered. The light sources used to illuminate the recorded holograms are very important to obtain ultra-realistic 3-D images. In particular the new light sources based on RGB LEDs are described. They show improved image quality over today's commonly used halogen lights. Recent work in colour holography by holographers and companies in different countries around the world are included. To record and display ultra-realistic 3-D images with perfect colour rendering are highly dependent on the correct recording technique using the optimal recording laser wavelengths, the availability of improved panchromatic recording materials and combined with new display light sources.

  11. Appearance-based color face recognition with 3D model

    NASA Astrophysics Data System (ADS)

    Wang, Chengzhang; Bai, Xiaoming

    2013-03-01

    Appearance-based face recognition approaches explore color cues of face images, i.e. grey or color information for recognition task. They first encode color face images, and then extract facial features for classification. Similar to conventional singular value decomposition, hypercomplex matrix also exists singular value decomposition on hypercomplex field. In this paper, a novel color face recognition approach based on hypercomplex singular value decomposition is proposed. The approach employs hypercomplex to encode color face information of different channels simultaneously. Hypercomplex singular value decomposition is utilized then to compute the basis vectors of the color face subspace. To improve learning efficiency of the algorithm, 3D active deformable model is exploited to generate virtual face images. Color face samples are projected onto the subspace and projection coefficients are utilized as facial features. Experimental results on CMU PIE face database verify the effectiveness of the proposed approach.

  12. Improving 3D Wavelet-Based Compression of Hyperspectral Images

    NASA Technical Reports Server (NTRS)

    Klimesh, Matthew; Kiely, Aaron; Xie, Hua; Aranki, Nazeeh

    2009-01-01

    Two methods of increasing the effectiveness of three-dimensional (3D) wavelet-based compression of hyperspectral images have been developed. (As used here, images signifies both images and digital data representing images.) The methods are oriented toward reducing or eliminating detrimental effects of a phenomenon, referred to as spectral ringing, that is described below. In 3D wavelet-based compression, an image is represented by a multiresolution wavelet decomposition consisting of several subbands obtained by applying wavelet transforms in the two spatial dimensions corresponding to the two spatial coordinate axes of the image plane, and by applying wavelet transforms in the spectral dimension. Spectral ringing is named after the more familiar spatial ringing (spurious spatial oscillations) that can be seen parallel to and near edges in ordinary images reconstructed from compressed data. These ringing phenomena are attributable to effects of quantization. In hyperspectral data, the individual spectral bands play the role of edges, causing spurious oscillations to occur in the spectral dimension. In the absence of such corrective measures as the present two methods, spectral ringing can manifest itself as systematic biases in some reconstructed spectral bands and can reduce the effectiveness of compression of spatially-low-pass subbands. One of the two methods is denoted mean subtraction. The basic idea of this method is to subtract mean values from spatial planes of spatially low-pass subbands prior to encoding, because (a) such spatial planes often have mean values that are far from zero and (b) zero-mean data are better suited for compression by methods that are effective for subbands of two-dimensional (2D) images. In this method, after the 3D wavelet decomposition is performed, mean values are computed for and subtracted from each spatial plane of each spatially-low-pass subband. The resulting data are converted to sign-magnitude form and compressed in a

  13. 3D modeling based on CityEngine

    NASA Astrophysics Data System (ADS)

    Jia, Guangyin; Liao, Kaiju

    2017-03-01

    Currently, there are many 3D modeling softwares, like 3DMAX, AUTOCAD, and more populous BIM softwares represented by REVIT. CityEngine modeling software introduced in this paper can fully utilize the existing GIS data and combine other built models to make 3D modeling on internal and external part of buildings in a rapid and batch manner, so as to improve the 3D modeling efficiency.

  14. 3D Gabor wavelet based vessel filtering of photoacoustic images.

    PubMed

    Haq, Israr Ul; Nagoaka, Ryo; Makino, Takahiro; Tabata, Takuya; Saijo, Yoshifumi

    2016-08-01

    Filtering and segmentation of vasculature is an important issue in medical imaging. The visualization of vasculature is crucial for the early diagnosis and therapy in numerous medical applications. This paper investigates the use of Gabor wavelet to enhance the effect of vasculature while eliminating the noise due to size, sensitivity and aperture of the detector in 3D Optical Resolution Photoacoustic Microscopy (OR-PAM). A detailed multi-scale analysis of wavelet filtering and Hessian based method is analyzed for extracting vessels of different sizes since the blood vessels usually vary with in a range of radii. The proposed algorithm first enhances the vasculature in the image and then tubular structures are classified by eigenvalue decomposition of the local Hessian matrix at each voxel in the image. The algorithm is tested on non-invasive experiments, which shows appreciable results to enhance vasculature in photo-acoustic images.

  15. Imaging of prostate cancer: a platform for 3D co-registration of in-vivo MRI ex-vivo MRI and pathology

    NASA Astrophysics Data System (ADS)

    Orczyk, Clément; Mikheev, Artem; Rosenkrantz, Andrew; Melamed, Jonathan; Taneja, Samir S.; Rusinek, Henry

    2012-02-01

    Objectives: Multi-parametric MRI is emerging as a promising method for prostate cancer diagnosis. prognosis and treatment planning. However, the localization of in-vivo detected lesions and pathologic sites of cancer remains a significant challenge. To overcome this limitation we have developed and tested a system for co-registration of in-vivo MRI, ex-vivo MRI and histology. Materials and Methods: Three men diagnosed with localized prostate cancer (ages 54-72, PSA levels 5.1-7.7 ng/ml) were prospectively enrolled in this study. All patients underwent 3T multi-parametric MRI that included T2W, DCEMRI, and DWI prior to robotic-assisted prostatectomy. Ex-vivo multi-parametric MRI was performed on fresh prostate specimen. Excised prostates were then sliced at regular intervals and photographed both before and after fixation. Slices were perpendicular to the main axis of the posterior capsule, i.e., along the direction of the rectal wall. Guided by the location of the urethra, 2D digital images were assembled into 3D models. Cancer foci, extra-capsular extensions and zonal margins were delineated by the pathologist and included in 3D histology data. A locally-developed software was applied to register in-vivo, ex-vivo and histology using an over-determined set of anatomical landmarks placed in anterior fibro-muscular stroma, central. transition and peripheral zones. The mean root square distance across corresponding control points was used to assess co-registration error. Results: Two specimens were pT3a and one pT2b (negative margin) at pathology. The software successfully fused invivo MRI. ex-vivo MRI fresh specimen and histology using appropriate (rigid and affine) transformation models with mean square error of 1.59 mm. Coregistration accuracy was confirmed by multi-modality viewing using operator-guided variable transparency. Conclusion: The method enables successful co-registration of pre-operative MRI, ex-vivo MRI and pathology and it provides initial evidence

  16. High speed 3D overhauser-enhanced MRI using combined b-SSFP and compressed sensing.

    PubMed

    Sarracanie, Mathieu; Armstrong, Brandon D; Stockmann, Jason; Rosen, Matthew S

    2014-02-01

    Overhauser-enhanced MRI is a promising technique for imaging the distribution and dynamics of free radicals. A key challenge for Overhauser-enhanced MRI is attaining high spatial and temporal resolution while simultaneously limiting resonator and sample heating due to the long, high power radio-frequency pulses needed to saturate the electron resonance. The approach presented here embeds EPR pulses within a balanced steady state free precession sequence. Unlike other Overhauser-enhanced MRI methods, no separate Overhauser prepolarization step is required. This steady-state approach also eliminates the problem of time-varying Overhauser-enhanced signal and provides constant polarization in the sample during the acquisition. A further increase in temporal resolution was achieved by incorporating undersampled k-space strategies and compressed sensing reconstruction. We demonstrate 1 × 2 × 3.5 mm(3) resolution at 6.5 mT across a 54 × 54 × 110 mm(3) sample in 33 s while sampling 30% of k-space. The work presented here overcomes the main limitations of Overhauser enhanced MRI as previously described in the literature, drastically improving speed and resolution, and enabling new opportunities for the measurement of free radicals in living organisms, and for the study of dynamic processes such as metabolism and flow. Copyright © 2013 Wiley Periodicals, Inc.

  17. Lung Motion and Volume Measurement by Dynamic 3D MRI Using a 128-Channel Receiver Coil1

    PubMed Central

    Tokuda, Junichi; Schmitt, Melanie; Sun, Yanping; Patz, Samuel; Tang, Yi; Mountford, Carolyn E.; Hata, Nobuhiko; Wald, Lawrence L.; Hatabu, Hiroto

    2009-01-01

    Rationale and Objectives The authors present their initial experience using a 3-T whole-body scanner equipped with a 128-channel coil applied to lung motion assessment. Recent improvements in fast magnetic resonance imaging (MRI) technology have enabled several trials of free-breathing three-dimensional (3D) imaging of the lung. A large number of image frames necessarily increases the difficulty of image analysis and therefore warrants automatic image processing. However, the intensity homogeneities of images of prior dynamic 3D lung MRI studies have been insufficient to use such methods. In this study, initial data were obtained at 3 T with a 128-channel coil that demonstrate the feasibility of acquiring multiple sets of 3D pulmonary scans during free breathing and that have sufficient quality to be amenable to automatic segmentation. Materials and Methods Dynamic 3D images of the lungs of two volunteers were acquired with acquisition times of 0.62 to 0.76 frames/s and an image matrix of 128 × 128, with 24 to 30 slice encodings. The volunteers were instructed to take shallow and deep breaths during the scans. The variation of lung volume was measured from the segmented images. Results Dynamic 3D images were successfully acquired for both respiratory conditions for each subject. The images showed whole-lung motion, including lifting of the chest wall and the displacement of the diaphragm, with sufficient contrast to distinguish these structures from adjacent tissues. The average time to complete segmentation for one 3D image was 4.8 seconds. The tidal volume measured was consistent with known tidal volumes for healthy subjects performing deep-breathing maneuvers. The temporal resolution was insufficient to measure tidal volumes for shallow breathing. Conclusion This initial experience with a 3-T whole-body scanner and a 128-channel coil showed that the scanner and imaging protocol provided dynamic 3D images with spatial and temporal resolution sufficient to

  18. Theoretical Analysis of the Accuracy and Safety of MRI-Guided Transurethral 3-D Conformal Ultrasound Prostate Therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound therapy is a promising new approach for the treatment of localized prostate cancer. Several studies have demonstrated the feasibility of producing large regions of thermal coagulation adequate for prostate therapy; however, the quantitative assessment of shaping these regions to complex 3-D human prostate geometries has not been fully explored. This study used numerical simulations and twenty manually-segmented pelvic anatomical models derived from high-quality MR images of prostate cancer patients to evaluate the treatment accuracy and safety of 3-D conformal MRI-guided transurethral ultrasound therapy. The simulations incorporated a rotating multi-element planar dual-frequency ultrasound transducer (seventeen 4×3 mm elements) operating at 4.7/9.7 MHz and 10 W/cm2 maximum acoustic power. Results using a novel feedback control algorithm which modulated the ultrasound frequency, power and device rate of rotation showed that regions of thermal coagulation could be shaped to predefined prostate volumes within 1.0 mm across the vast majority of these glands. Treatment times were typically 30 min and remained below 60 min for large 60 cc prostates. With a rectal cooling temperature of 15° C, the rectal wall did not exceed 30EM43 in half of the twenty patient models with only a few 1 mm3 voxels above this threshold in the other cases. At 4.7 MHz, heating of the pelvic bone can become significant when it is located less than 10 mm from the prostate. Numerical simulations show that MRI-guided transurethral ultrasound therapy can thermally coagulate whole prostate glands accurately and safely in 3-D.

  19. A Web platform for the interactive visualization and analysis of the 3D fractal dimension of MRI data.

    PubMed

    Jiménez, J; López, A M; Cruz, J; Esteban, F J; Navas, J; Villoslada, P; Ruiz de Miras, J

    2014-10-01

    This study presents a Web platform (http://3dfd.ujaen.es) for computing and analyzing the 3D fractal dimension (3DFD) from volumetric data in an efficient, visual and interactive way. The Web platform is specially designed for working with magnetic resonance images (MRIs) of the brain. The program estimates the 3DFD by calculating the 3D box-counting of the entire volume of the brain, and also of its 3D skeleton. All of this is done in a graphical, fast and optimized way by using novel technologies like CUDA and WebGL. The usefulness of the Web platform presented is demonstrated by its application in a case study where an analysis and characterization of groups of 3D MR images is performed for three neurodegenerative diseases: Multiple Sclerosis, Intrauterine Growth Restriction and Alzheimer's disease. To the best of our knowledge, this is the first Web platform that allows the users to calculate, visualize, analyze and compare the 3DFD from MRI images in the cloud.

  20. Hydrogel-based reinforcement of 3D bioprinted constructs

    PubMed Central

    Levato, R; Peiffer, Q C; de Ruijter, M; Hennink, W E; Vermonden, T; Malda, J

    2016-01-01

    Progress within the field of biofabrication is hindered by a lack of suitable hydrogel formulations. Here, we present a novel approach based on a hybrid printing technique to create cellularized 3D printed constructs. The hybrid bioprinting strategy combines a reinforcing gel for mechanical support with a bioink to provide a cytocompatible environment. In comparison with thermoplastics such as є-polycaprolactone, the hydrogel-based reinforcing gel platform enables printing at cell-friendly temperatures, targets the bioprinting of softer tissues and allows for improved control over degradation kinetics. We prepared amphiphilic macromonomers based on poloxamer that form hydrolysable, covalently cross-linked polymer networks. Dissolved at a concentration of 28.6%w/w in water, it functions as reinforcing gel, while a 5%w/w gelatin-methacryloyl based gel is utilized as bioink. This strategy allows for the creation of complex structures, where the bioink provides a cytocompatible environment for encapsulated cells. Cell viability of equine chondrocytes encapsulated within printed constructs remained largely unaffected by the printing process. The versatility of the system is further demonstrated by the ability to tune the stiffness of printed constructs between 138 and 263 kPa, as well as to tailor the degradation kinetics of the reinforcing gel from several weeks up to more than a year. PMID:27431861

  1. Creating pathology models from MRI data: a comparison of virtual 3D modelling and rapid prototyping techniques.

    PubMed

    Challoner, Alexandra; Erolin, Caroline

    2013-06-01

    This paper discusses a pilot study in collaboration between the Centre for Anatomy and Human Identification and the Pathology Department at Ninewells Hospital, Dundee. Anonymised patient MRI data depicting renal cancer was used to create a virtual 3D model and two rapid prototype models of the kidneys and surrounding anatomy. A questionnaire was conducted to collect feedback from tutors and students in order to evaluate the models and determine user preference. It was found that the majority preferred the physical models to the virtual model.

  2. Bias Field Inconsistency Correction of Motion-Scattered Multislice MRI for Improved 3D Image Reconstruction

    PubMed Central

    Kim, Kio; Habas, Piotr A.; Rajagopalan, Vidya; Scott, Julia A.; Corbett-Detig, James M.; Rousseau, Francois; Barkovich, A. James; Glenn, Orit A.; Studholme, Colin

    2012-01-01

    A common solution to clinical MR imaging in the presence of large anatomical motion is to use fast multi-slice 2D studies to reduce slice acquisition time and provide clinically usable slice data. Recently, techniques have been developed which retrospectively correct large scale 3D motion between individual slices allowing the formation of a geometrically correct 3D volume from the multiple slice stacks. One challenge, however, in the final reconstruction process is the possibility of varying intensity bias in the slice data, typically due to the motion of the anatomy relative to imaging coils. As a result, slices which cover the same region of anatomy at different times may exhibit different sensitivity. This bias field inconsistency can induce artifacts in the final 3D reconstruction that can impact both clinical interpretation of key tissue boundaries and the automated analysis of the data. Here we describe a framework to estimate and correct the bias field inconsistency in each slice collectively across all motion corrupted image slices. Experiments using synthetic and clinical data show that the proposed method reduces intensity variability in tissues and improves the distinction between key tissue types. PMID:21511561

  3. Bias field inconsistency correction of motion-scattered multislice MRI for improved 3D image reconstruction.

    PubMed

    Kim, Kio; Habas, Piotr A; Rajagopalan, Vidya; Scott, Julia A; Corbett-Detig, James M; Rousseau, Francois; Barkovich, A James; Glenn, Orit A; Studholme, Colin

    2011-09-01

    A common solution to clinical MR imaging in the presence of large anatomical motion is to use fast multislice 2D studies to reduce slice acquisition time and provide clinically usable slice data. Recently, techniques have been developed which retrospectively correct large scale 3D motion between individual slices allowing the formation of a geometrically correct 3D volume from the multiple slice stacks. One challenge, however, in the final reconstruction process is the possibility of varying intensity bias in the slice data, typically due to the motion of the anatomy relative to imaging coils. As a result, slices which cover the same region of anatomy at different times may exhibit different sensitivity. This bias field inconsistency can induce artifacts in the final 3D reconstruction that can impact both clinical interpretation of key tissue boundaries and the automated analysis of the data. Here we describe a framework to estimate and correct the bias field inconsistency in each slice collectively across all motion corrupted image slices. Experiments using synthetic and clinical data show that the proposed method reduces intensity variability in tissues and improves the distinction between key tissue types.

  4. Energy harvesting “3-D knitted spacer” based piezoelectric textiles

    NASA Astrophysics Data System (ADS)

    Anand, S.; Soin, N.; Shah, T. H.; Siores, E.

    2016-07-01

    The piezoelectric effect in Poly(vinylidene fluoride), PVDF, was discovered over four decades ago and since then, significant work has been carried out aiming at the production of high p-phase fibres and their integration into fabric structures for energy harvesting. However, little work has been done in the area of production of “true piezoelectric fabric structures” based on flexible polymeric materials such as PVDF. In this work, we demonstrate “3-D knitted spacer” technology based all-fibre piezoelectric fabrics as power generators and energy harvesters. The knitted single-structure piezoelectric generator consists of high p-phase (~80%) piezoelectric PVDF monofilaments as the spacer yarn interconnected between silver (Ag) coated polyamide multifilament yarn layers acting as the top and bottom electrodes. The novel and unique textile structure provides an output power density in the range of 1.105.10 gWcm-2 at applied impact pressures in the range of 0.02-0.10 MPa, thus providing significantly higher power outputs and efficiencies over the existing 2-D woven and nonwoven piezoelectric structures. The high energy efficiency, mechanical durability and comfort of the soft, flexible and all-fibre based power generator is highly attractive for a variety of potential applications such as wearable electronic systems and energy harvesters charged from ambient environment or by human movement.

  5. 3D pattern of brain atrophy in HIV/AIDS visualized using tensor-based morphometry

    PubMed Central

    Chiang, Ming-Chang; Dutton, Rebecca A.; Hayashi, Kiralee M.; Lopez, Oscar L.; Aizenstein, Howard J.; Toga, Arthur W.; Becker, James T.; Thompson, Paul M.

    2011-01-01

    35% of HIV-infected patients have cognitive impairment, but the profile of HIV-induced brain damage is still not well understood. Here we used tensor-based morphometry (TBM) to visualize brain deficits and clinical/anatomical correlations in HIV/AIDS. To perform TBM, we developed a new MRI-based analysis technique that uses fluid image warping, and a new α-entropy-based information-theoretic measure of image correspondence, called the Jensen–Rényi divergence (JRD). Methods 3D T1-weighted brain MRIs of 26 AIDS patients (CDC stage C and/or 3 without HIV-associated dementia; 47.2 ± 9.8 years; 25M/1F; CD4+ T-cell count: 299.5 ± 175.7/µl; log10 plasma viral load: 2.57 ± 1.28 RNA copies/ml) and 14 HIV-seronegative controls (37.6 ± 12.2 years; 8M/6F) were fluidly registered by applying forces throughout each deforming image to maximize the JRD between it and a target image (from a control subject). The 3D fluid registration was regularized using the linearized Cauchy–Navier operator. Fine-scale volumetric differences between diagnostic groups were mapped. Regions were identified where brain atrophy correlated with clinical measures. Results Severe atrophy (~15–20% deficit) was detected bilaterally in the primary and association sensorimotor areas. Atrophy of these regions, particularly in the white matter, correlated with cognitive impairment (P=0.033) and CD4+ T-lymphocyte depletion (P=0.005). Conclusion TBM facilitates 3D visualization of AIDS neuropathology in living patients scanned with MRI. Severe atrophy in frontoparietal and striatal areas may underlie early cognitive dysfunction in AIDS patients, and may signal the imminent onset of AIDS dementia complex. PMID:17035049

  6. Crop 3D-a LiDAR based platform for 3D high-throughput crop phenotyping.

    PubMed

    Guo, Qinghua; Wu, Fangfang; Pang, Shuxin; Zhao, Xiaoqian; Chen, Linhai; Liu, Jin; Xue, Baolin; Xu, Guangcai; Li, Le; Jing, Haichun; Chu, Chengcai

    2017-12-06

    With the growing population and the reducing arable land, breeding has been considered as an effective way to solve the food crisis. As an important part in breeding, high-throughput phenotyping can accelerate the breeding process effectively. Light detection and ranging (LiDAR) is an active remote sensing technology that is capable of acquiring three-dimensional (3D) data accurately, and has a great potential in crop phenotyping. Given that crop phenotyping based on LiDAR technology is not common in China, we developed a high-throughput crop phenotyping platform, named Crop 3D, which integrated LiDAR sensor, high-resolution camera, thermal camera and hyperspectral imager. Compared with traditional crop phenotyping techniques, Crop 3D can acquire multi-source phenotypic data in the whole crop growing period and extract plant height, plant width, leaf length, leaf width, leaf area, leaf inclination angle and other parameters for plant biology and genomics analysis. In this paper, we described the designs, functions and testing results of the Crop 3D platform, and briefly discussed the potential applications and future development of the platform in phenotyping. We concluded that platforms integrating LiDAR and traditional remote sensing techniques might be the future trend of crop high-throughput phenotyping.

  7. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    fabrication. An FDA approved radially- phased 64-element array intravascular ultrasound ( IVUS ) device (Visions, Volcano Therapeutics) 8.2 French...catheter and Volcano s5 imaging system were used for the TUUS imaging. The IVUS was electronically controlled to yield 2D images that were stitched to...the stability of the phantoms over time, acquiring IVUS catheters, access to the imaging tools (TUUS imaging machine, TRUS imaging machine and MRI

  8. 3D model-based still image object categorization

    NASA Astrophysics Data System (ADS)

    Petre, Raluca-Diana; Zaharia, Titus

    2011-09-01

    This paper proposes a novel recognition scheme algorithm for semantic labeling of 2D object present in still images. The principle consists of matching unknown 2D objects with categorized 3D models in order to infer the semantics of the 3D object to the image. We tested our new recognition framework by using the MPEG-7 and Princeton 3D model databases in order to label unknown images randomly selected from the web. Results obtained show promising performances, with recognition rate up to 84%, which opens interesting perspectives in terms of semantic metadata extraction from still images/videos.

  9. Cloud Based Web 3d GIS Taiwan Platform

    NASA Astrophysics Data System (ADS)

    Tsai, W.-F.; Chang, J.-Y.; Yan, S. Y.; Chen, B.

    2011-09-01

    This article presents the status of the web 3D GIS platform, which has been developed in the National Applied Research Laboratories. The purpose is to develop a global earth observation 3D GIS platform for applications to disaster monitoring and assessment in Taiwan. For quick response to preliminary and detailed assessment after a natural disaster occurs, the web 3D GIS platform is useful to access, transfer, integrate, display and analyze the multi-scale huge data following the international OGC standard. The framework of cloud service for data warehousing management and efficiency enhancement using VMWare is illustrated in this article.

  10. Computation of 3D queries for ROCS based virtual screens.

    PubMed

    Tawa, Gregory J; Baber, J Christian; Humblet, Christine

    2009-12-01

    Rapid overlay of chemical structures (ROCS) is a method that aligns molecules based on shape and/or chemical similarity. It is often used in 3D ligand-based virtual screening. Given a query consisting of a single conformation of an active molecule ROCS can generate highly enriched hit lists. Typically the chosen query conformation is a minimum energy structure. Can better enrichment be obtained using conformations other than the minimum energy structure? To answer this question a methodology has been developed called CORAL (COnformational analysis, Rocs ALignment). For a given set of molecule conformations it computes optimized conformations for ROCS screening. It does so by clustering all conformations of a chosen molecule set using pairwise ROCS combo scores. The best representative conformation is that which has the highest average overlap with the rest of the conformations in the cluster. It is these best representative conformations that are then used for virtual screening. CORAL was tested by performing virtual screening experiments with the 40 DUD (Directory of Useful Decoys) data sets. Both CORAL and minimum energy queries were used. The recognition capability of each query was quantified as the area under the ROC curve (AUC). Results show that the CORAL AUC values are on average larger than the minimum energy AUC values. This demonstrates that one can indeed obtain better ROCS enrichments with conformations other than the minimum energy structure. As a result, CORAL analysis can be a valuable first step in virtual screening workflows using ROCS.

  11. Computation of 3D queries for ROCS based virtual screens

    NASA Astrophysics Data System (ADS)

    Tawa, Gregory J.; Baber, J. Christian; Humblet, Christine

    2009-12-01

    Rapid overlay of chemical structures (ROCS) is a method that aligns molecules based on shape and/or chemical similarity. It is often used in 3D ligand-based virtual screening. Given a query consisting of a single conformation of an active molecule ROCS can generate highly enriched hit lists. Typically the chosen query conformation is a minimum energy structure. Can better enrichment be obtained using conformations other than the minimum energy structure? To answer this question a methodology has been developed called CORAL (COnformational analysis, Rocs ALignment). For a given set of molecule conformations it computes optimized conformations for ROCS screening. It does so by clustering all conformations of a chosen molecule set using pairwise ROCS combo scores. The best representative conformation is that which has the highest average overlap with the rest of the conformations in the cluster. It is these best representative conformations that are then used for virtual screening. CORAL was tested by performing virtual screening experiments with the 40 DUD (Directory of Useful Decoys) data sets. Both CORAL and minimum energy queries were used. The recognition capability of each query was quantified as the area under the ROC curve (AUC). Results show that the CORAL AUC values are on average larger than the minimum energy AUC values. This demonstrates that one can indeed obtain better ROCS enrichments with conformations other than the minimum energy structure. As a result, CORAL analysis can be a valuable first step in virtual screening workflows using ROCS.

  12. Virtual reality 3D headset based on DMD light modulators

    NASA Astrophysics Data System (ADS)

    Bernacki, Bruce E.; Evans, Allan; Tang, Edward

    2014-06-01

    We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micromirror devices (DMD). Current methods for presenting information for virtual reality are focused on either polarizationbased modulators such as liquid crystal on silicon (LCoS) devices, or miniature LCD or LED displays often using lenses to place the image at infinity. LCoS modulators are an area of active research and development, and reduce the amount of viewing light by 50% due to the use of polarization. Viewable LCD or LED screens may suffer low resolution, cause eye fatigue, and exhibit a "screen door" or pixelation effect due to the low pixel fill factor. Our approach leverages a mature technology based on silicon micro mirrors delivering 720p resolution displays in a small form-factor with high fill factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high-definition resolution and low power consumption, and many of the design methods developed for DMD projector applications can be adapted to display use. Potential applications include night driving with natural depth perception, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design concept is described in which light from the DMD is imaged to infinity and the user's own eye lens forms a real image on the user's retina resulting in a virtual retinal display.

  13. 3D Texture Analysis Reveals Imperceptible MRI Textural Alterations in the Thalamus and Putamen in Progressive Myoclonic Epilepsy Type 1, EPM1

    PubMed Central

    Suoranta, Sanna; Holli-Helenius, Kirsi; Koskenkorva, Päivi; Niskanen, Eini; Könönen, Mervi; Äikiä, Marja; Eskola, Hannu; Kälviäinen, Reetta; Vanninen, Ritva

    2013-01-01

    Progressive myoclonic epilepsy type 1 (EPM1) is an autosomal recessively inherited neurodegenerative disorder characterized by young onset age, myoclonus and tonic-clonic epileptic seizures. At the time of diagnosis, the visual assessment of the brain MRI is usually normal, with no major changes found later. Therefore, we utilized texture analysis (TA) to characterize and classify the underlying properties of the affected brain tissue by means of 3D texture features. Sixteen genetically verified patients with EPM1 and 16 healthy controls were included in the study. TA was performed upon 3D volumes of interest that were placed bilaterally in the thalamus, amygdala, hippocampus, caudate nucleus and putamen. Compared to the healthy controls, EPM1 patients had significant textural differences especially in the thalamus and right putamen. The most significantly differing texture features included parameters that measure the complexity and heterogeneity of the tissue, such as the co-occurrence matrix-based entropy and angular second moment, and also the run-length matrix-based parameters of gray-level non-uniformity, short run emphasis and long run emphasis. This study demonstrates the usability of 3D TA for extracting additional information from MR images. Textural alterations which suggest complex, coarse and heterogeneous appearance were found bilaterally in the thalamus, supporting the previous literature on thalamic pathology in EPM1. The observed putamenal involvement is a novel finding. Our results encourage further studies on the clinical applications, feasibility, reproducibility and reliability of 3D TA. PMID:23922849

  14. 3D texture analysis reveals imperceptible MRI textural alterations in the thalamus and putamen in progressive myoclonic epilepsy type 1, EPM1.

    PubMed

    Suoranta, Sanna; Holli-Helenius, Kirsi; Koskenkorva, Päivi; Niskanen, Eini; Könönen, Mervi; Äikiä, Marja; Eskola, Hannu; Kälviäinen, Reetta; Vanninen, Ritva

    2013-01-01

    Progressive myoclonic epilepsy type 1 (EPM1) is an autosomal recessively inherited neurodegenerative disorder characterized by young onset age, myoclonus and tonic-clonic epileptic seizures. At the time of diagnosis, the visual assessment of the brain MRI is usually normal, with no major changes found later. Therefore, we utilized texture analysis (TA) to characterize and classify the underlying properties of the affected brain tissue by means of 3D texture features. Sixteen genetically verified patients with EPM1 and 16 healthy controls were included in the study. TA was performed upon 3D volumes of interest that were placed bilaterally in the thalamus, amygdala, hippocampus, caudate nucleus and putamen. Compared to the healthy controls, EPM1 patients had significant textural differences especially in the thalamus and right putamen. The most significantly differing texture features included parameters that measure the complexity and heterogeneity of the tissue, such as the co-occurrence matrix-based entropy and angular second moment, and also the run-length matrix-based parameters of gray-level non-uniformity, short run emphasis and long run emphasis. This study demonstrates the usability of 3D TA for extracting additional information from MR images. Textural alterations which suggest complex, coarse and heterogeneous appearance were found bilaterally in the thalamus, supporting the previous literature on thalamic pathology in EPM1. The observed putamenal involvement is a novel finding. Our results encourage further studies on the clinical applications, feasibility, reproducibility and reliability of 3D TA.

  15. Gis-Based Smart Cartography Using 3d Modeling

    NASA Astrophysics Data System (ADS)

    Malinverni, E. S.; Tassetti, A. N.

    2013-08-01

    3D City Models have evolved to be important tools for urban decision processes and information systems, especially in planning, simulation, analysis, documentation and heritage management. On the other hand existing and in use numerical cartography is often not suitable to be used in GIS because not geometrically and topologically correctly structured. The research aim is to 3D structure and organize a numeric cartography for GIS and turn it into CityGML standardized features. The work is framed around a first phase of methodological analysis aimed to underline which existing standard (like ISO and OGC rules) can be used to improve the quality requirement of a cartographic structure. Subsequently, from this technical specifics, it has been investigated the translation in formal contents, using an owner interchange software (SketchUp), to support some guide lines implementations to generate a GIS3D structured in GML3. It has been therefore predisposed a test three-dimensional numerical cartography (scale 1:500, generated from range data captured by 3D laser scanner), tested on its quality according to the previous standard and edited when and where necessary. Cad files and shapefiles are converted into a final 3D model (Google SketchUp model) and then exported into a 3D city model (CityGML LoD1/LoD2). The GIS3D structure has been managed in a GIS environment to run further spatial analysis and energy performance estimate, not achievable in a 2D environment. In particular geometrical building parameters (footprint, volume etc.) are computed and building envelop thermal characteristics are derived from. Lastly, a simulation is carried out to deal with asbestos and home renovating charges and show how the built 3D city model can support municipal managers with risk diagnosis of the present situation and development of strategies for a sustainable redevelop.

  16. Detection of infarct lesions from single MRI modality using inconsistency between voxel intensity and spatial location--a 3-D automatic approach.

    PubMed

    Shen, Shan; Szameitat, André J; Sterr, Annette

    2008-07-01

    Detection of infarct lesions using traditional segmentation methods is always problematic due to intensity similarity between lesions and normal tissues, so that multispectral MRI modalities were often employed for this purpose. However, the high costs of MRI scan and the severity of patient conditions restrict the collection of multiple images. Therefore, in this paper, a new 3-D automatic lesion detection approach was proposed, which required only a single type of anatomical MRI scan. It was developed on a theory that, when lesions were present, the voxel-intensity-based segmentation and the spatial-location-based tissue distribution should be inconsistent in the regions of lesions. The degree of this inconsistency was calculated, which indicated the likelihood of tissue abnormality. Lesions were identified when the inconsistency exceeded a defined threshold. In this approach, the intensity-based segmentation was implemented by the conventional fuzzy c-mean (FCM) algorithm, while the spatial location of tissues was provided by prior tissue probability maps. The use of simulated MRI lesions allowed us to quantitatively evaluate the performance of the proposed method, as the size and location of lesions were prespecified. The results showed that our method effectively detected lesions with 40-80% signal reduction compared to normal tissues (similarity index > 0.7). The capability of the proposed method in practice was also demonstrated on real infarct lesions from 15 stroke patients, where the lesions detected were in broad agreement with true lesions. Furthermore, a comparison to a statistical segmentation approach presented in the literature suggested that our 3-D lesion detection approach was more reliable. Future work will focus on adapting the current method to multiple sclerosis lesion detection.

  17. Thermal 3D modeling system based on 3-view geometry

    NASA Astrophysics Data System (ADS)

    Yu, Sunjin; Kim, Joongrock; Lee, Sangyoun

    2012-11-01

    In this paper, we propose a novel thermal three-dimensional (3D) modeling system that includes 3D shape, visual, and thermal infrared information and solves a registration problem among these three types of information. The proposed system consists of a projector, a visual camera and, a thermal camera (PVT). To generate 3D shape information, we use a structured light technique, which consists of a visual camera and a projector. A thermal camera is added to the structured light system in order to provide thermal information. To solve the correspondence problem between the three sensors, we use three-view geometry. Finally, we obtain registered PVT data, which includes visual, thermal, and 3D shape information. Among various potential applications such as industrial measurements, biological experiments, military usage, and so on, we have adapted the proposed method to biometrics, particularly for face recognition. With the proposed method, we obtain multi-modal 3D face data that includes not only textural information but also data regarding head pose, 3D shape, and thermal information. Experimental results show that the performance of the proposed face recognition system is not limited by head pose variation which is a serious problem in face recognition.

  18. In vivo high-resolution 3D overhauser-enhanced MRI in mice at 0.2 T.

    PubMed

    Massot, Philippe; Parzy, Elodie; Pourtau, Line; Mellet, Philippe; Madelin, Guillaume; Marque, Sylvain; Franconi, Jean-Michel; Thiaudiere, Eric

    2012-01-01

    Overhauser-enhanced MRI (OMRI) offers the potentiality of detecting low-concentrated species generated by specific biological processes. However molecular imaging applications of OMRI need significant improvement in spatial localization. Here it is shown that 3D-OMRI of a free radical injected in tumor-bearing mice can be performed at high anatomical resolution at a constant field. A 30 mm cavity operating at 5.43 GHz was inserted in a C-shaped magnet for proton MRI at 0.194 T. Nude mice with or without brain-implanted C6 rat glioma were positioned in the cavity and injected with TOPCA (1-oxyl-2,2,5,5-tetramethyl-2,5-dihydro-1H-pyrrole-3-carboxylic acid). OMRI was performed in 3D within several minutes in the brain region without high overheating of the animals. Voxel size was 0.5 × 0.5 × 1 mm³ , providing good delineation of brain regions. Signal amplifications ranged from 2 in tumors to 10 in vessels several minutes after TOPCA injection. Time-course of signal enhancement could be measured by 2D OMRI at 15 s time intervals in a localized thin slice. The method opens the way for molecular imaging of biological activities able to generate OMRI-visible free radicals. Copyright © 2012 John Wiley & Sons, Ltd.

  19. 3-D volumetric MRI evaluation of the placenta in fetuses with complex congenital heart disease

    PubMed Central

    Andescavage, Nickie; Yarish, Alexa; Donofrio, Mary; Bulas, Dorothy; Evangelou, Iordanis; Vezina, Gilbert; McCarter, Robert; DuPlessis, Adre; Limperopoulos, Catherine

    2015-01-01

    Introduction Placental insufficiency remains a common cause of perinatal mortality and neurodevelopmental morbidity. Congenital heart disease (CHD) in the fetus and its relationship to placental function is unknown. This study explores placental health and its relationship to neonatal outcomes by comparing placental volumes in healthy pregnancies and pregnancies complicated by CHD using in vivo three-dimensional MRI studies. Methods In a prospective observational study, pregnant women greater than 18 weeks gestation with normal pregnancies or pregnancies complicated by CHD were recruited and underwent fetal MR imaging. The placenta was manually outlined and the volume was calculated in cm3. Brain volume was also calculated and clinical data were also collected. Relationships, including interactive effects, between placental and fetal growth, including brain growth, were evaluated using longitudinal multiple linear regression analysis. Results 135 women underwent fetal MRI between 18 and 39 weeks gestation (mean 31.6 ± 4.4). Placental volume increased exponentially with gestational age (p=0.041). Placental volume was positively associated with birth weight (p <0.001) and increased more steeply with birth weight in CHD-affected fetuses (p=0.046). Total brain and cerebral volumes were smaller in the CHD group (p<0.001), but brainstem volume (p<0.001) was larger. Placental volumes were not associated with brain volumes. Discussion Impaired placental growth in CHD is associated with gestational age and birth weight at delivery. Abnormalities in placental development may contribute to the significant morbidity in this high-risk population. Assessment of placental volume by MRI allows for in vivo assessments of placental development. PMID:26190037

  20. 3-D volumetric MRI evaluation of the placenta in fetuses with complex congenital heart disease.

    PubMed

    Andescavage, Nickie; Yarish, Alexa; Donofrio, Mary; Bulas, Dorothy; Evangelou, Iordanis; Vezina, Gilbert; McCarter, Robert; duPlessis, Adre; Limperopoulos, Catherine

    2015-09-01

    Placental insufficiency remains a common cause of perinatal mortality and neurodevelopmental morbidity. Congenital heart disease (CHD) in the fetus and its relationship to placental function is unknown. This study explores placental health and its relationship to neonatal outcomes by comparing placental volumes in healthy pregnancies and pregnancies complicated by CHD using in vivo three-dimensional MRI studies. In a prospective observational study, pregnant women greater than 18 weeks gestation with normal pregnancies or pregnancies complicated by CHD were recruited and underwent fetal MR imaging. The placenta was manually outlined and the volume was calculated in cm(3). Brain volume was also calculated and clinical data were also collected. Relationships, including interactive effects, between placental and fetal growth, including brain growth, were evaluated using longitudinal multiple linear regression analysis. 135 women underwent fetal MRI between 18 and 39 weeks gestation (mean 31.6 ± 4.4). Placental volume increased exponentially with gestational age (p = 0.041). Placental volume was positively associated with birth weight (p < 0.001) and increased more steeply with birth weight in CHD-affected fetuses (p = 0.046). Total brain and cerebral volumes were smaller in the CHD group (p < 0.001), but brainstem volume (p < 0.001) was larger. Placental volumes were not associated with brain volumes. Impaired placental growth in CHD is associated with gestational age and birth weight at delivery. Abnormalities in placental development may contribute to the significant morbidity in this high-risk population. Assessment of placental volume by MRI allows for in vivo assessments of placental development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. 3D Source Localization of Interictal Spikes in Epilepsy Patients with MRI Lesions

    PubMed Central

    Ding, Lei; Worrell, Gregory A.; Lagerlund, Terrence D.; He, Bin

    2007-01-01

    Objective The present study aims to accurately localize epileptogenic regions which are responsible for epileptic activities in epilepsy patients by means of a new subspace source localization approach, i.e. First-principle-vectors (FINE), using scalp EEG recordings. Methods Computer simulations were first performed to assess source localization accuracy of FINE under the clinical electrode set-up. The source localization results from FINE were compared with the results from a classic subspace source localization approach, i.e. MUSIC, and their differences were tested statistically using the paired t-test. Other influence factors to source localization accuracy were assessed statistically by ANOVA. The interictal epileptiform spike data from three adult epilepsy patients with medically intractable partial epilepsy and well-defined symptomatic MRI lesions were then studied using both FINE and MUSIC. The comparison between the electrical sources estimated by the subspace source localization approaches and MRI lesions were made through the co-registration between the EEG recordings and MRI scans. The accuracy of estimations made by FINE and MUSIC was also evaluated and compared by R2 statistic, which was used to indicate the goodness-of-fit of the estimated sources to the scalp EEG recordings. The 3-concentric-spheres head volume conductor model was build for each patient with different radii of three spheres which takes the individual head size and thickness of individual skull into the consideration. Results The results from computer simulations indicate that the improvement of source spatial resolvability and localization accuracy of FINE as compared with MUSIC is significant when simulated sources are closely spaced, deep, or signal-to-noise-ratio is low in a clinical electrode set-up. The interictal electrical generators estimated by FINE and MUSIC are in concordance with the patients’ structural abnormality, i.e. MRI lesions, in all three patients. The higher

  2. 3D source localization of interictal spikes in epilepsy patients with MRI lesions

    NASA Astrophysics Data System (ADS)

    Ding, Lei; Worrell, Gregory A.; Lagerlund, Terrence D.; He, Bin

    2006-08-01

    The present study aims to accurately localize epileptogenic regions which are responsible for epileptic activities in epilepsy patients by means of a new subspace source localization approach, i.e. first principle vectors (FINE), using scalp EEG recordings. Computer simulations were first performed to assess source localization accuracy of FINE in the clinical electrode set-up. The source localization results from FINE were compared with the results from a classic subspace source localization approach, i.e. MUSIC, and their differences were tested statistically using the paired t-test. Other factors influencing the source localization accuracy were assessed statistically by ANOVA. The interictal epileptiform spike data from three adult epilepsy patients with medically intractable partial epilepsy and well-defined symptomatic MRI lesions were then studied using both FINE and MUSIC. The comparison between the electrical sources estimated by the subspace source localization approaches and MRI lesions was made through the coregistration between the EEG recordings and MRI scans. The accuracy of estimations made by FINE and MUSIC was also evaluated and compared by R2 statistic, which was used to indicate the goodness-of-fit of the estimated sources to the scalp EEG recordings. The three-concentric-spheres head volume conductor model was built for each patient with three spheres of different radii which takes the individual head size and skull thickness into consideration. The results from computer simulations indicate that the improvement of source spatial resolvability and localization accuracy of FINE as compared with MUSIC is significant when simulated sources are closely spaced, deep, or signal-to-noise ratio is low in a clinical electrode set-up. The interictal electrical generators estimated by FINE and MUSIC are in concordance with the patients' structural abnormality, i.e. MRI lesions, in all three patients. The higher R2 values achieved by FINE than MUSIC

  3. Open-GL-based stereo system for 3D measurements

    NASA Astrophysics Data System (ADS)

    Boochs, Frank; Gehrhoff, Anja; Neifer, Markus

    2000-05-01

    A stereo system designed and used for the measurement of 3D- coordinates within metric stereo image pairs will be presented. First, the motivation for the development is shown, allowing to evaluate stereo images. As the use and availability of metric images of digital type rapidly increases corresponding equipment for the measuring process is needed. Systems which have been developed up to now are either very special ones, founded on high end graphics workstations with an according pricing or simple ones with restricted measuring functionality. A new conception will be shown, avoiding special high end graphics hardware but providing the measuring functionality required. The presented stereo system is based on PC-hardware equipped with a graphic board and uses an object oriented programming technique. The specific needs of a measuring system are shown and the corresponding requirements which have to be met by the system. The key role of OpenGL is described, which supplies some elementary graphic functions, being directly supported by graphic boards and thus provides the performance needed. Further important aspects as modularity and hardware independence and their value for the solution are shown. Finally some sample functions concerned with image display and handling are presented in more detail.

  4. 3D Clumped Cell Segmentation Using Curvature Based Seeded Watershed.

    PubMed

    Atta-Fosu, Thomas; Guo, Weihong; Jeter, Dana; Mizutani, Claudia M; Stopczynski, Nathan; Sousa-Neves, Rui

    2016-12-01

    Image segmentation is an important process that separates objects from the background and also from each other. Applied to cells, the results can be used for cell counting which is very important in medical diagnosis and treatment, and biological research that is often used by scientists and medical practitioners. Segmenting 3D confocal microscopy images containing cells of different shapes and sizes is still challenging as the nuclei are closely packed. The watershed transform provides an efficient tool in segmenting such nuclei provided a reasonable set of markers can be found in the image. In the presence of low-contrast variation or excessive noise in the given image, the watershed transform leads to over-segmentation (a single object is overly split into multiple objects). The traditional watershed uses the local minima of the input image and will characteristically find multiple minima in one object unless they are specified (marker-controlled watershed). An alternative to using the local minima is by a supervised technique called seeded watershed, which supplies single seeds to replace the minima for the objects. Consequently, the accuracy of a seeded watershed algorithm relies on the accuracy of the predefined seeds. In this paper, we present a segmentation approach based on the geometric morphological properties of the 'landscape' using curvatures. The curvatures are computed as the eigenvalues of the Shape matrix, producing accurate seeds that also inherit the original shape of their respective cells. We compare with some popular approaches and show the advantage of the proposed method.

  5. Efficient streaming of stereoscopic depth-based 3D videos

    NASA Astrophysics Data System (ADS)

    Temel, Dogancan; Aabed, Mohammed; Solh, Mashhour; AlRegib, Ghaassan

    2013-02-01

    In this paper, we propose a method to extract depth from motion, texture and intensity. We first analyze the depth map to extract a set of depth cues. Then, based on these depth cues, we process the colored reference video, using texture, motion, luminance and chrominance content, to extract the depth map. The processing of each channel in the YCRCB-color space is conducted separately. We tested this approach on different video sequences with different monocular properties. The results of our simulations show that the extracted depth maps generate a 3D video with quality close to the video rendered using the ground truth depth map. We report objective results using 3VQM and subjective analysis via comparison of rendered images. Furthermore, we analyze the savings in bitrate as a consequence of eliminating the need for two video codecs, one for the reference color video and one for the depth map. In this case, only the depth cues are sent as a side information to the color video.

  6. Posterior Compartment Anatomy as seen in MRI and 3-D Reconstruction from Asymptomatic Nulliparas

    PubMed Central

    HSU, Yvonne; LEWICKY-GAUPP, Christina; De LANCEY, John O.L.

    2010-01-01

    Objective To identify characteristic anatomical features of the posterior compartment using MR cross-sectional anatomy and 3-D modeling. Study Design Supine, static proton-density MR images of 20 nulliparas were analyzed. MR images were used to create models in a selected exemplar. Results The compartment’s upper, mid, and lower segments are best seen in the axial plane. It is bounded inferiorly by the perineal body, ventrally by the posterior vaginal wall and dorsally by the levator ani muscles and coccyx. In the upper portion, the compartment is bordered laterally by the uterosacral ligaments while in the mid portion, there is more direct contact with the lateral levator ani muscles. In the lower portion, the contact becomes obliterated as the vagina and levator ani muscles become fused to one another and to the perineal body. Conclusion The posterior compartment has characteristic anatomic features in MR cross-sectional anatomy that can be further elucidated and integrated with 3-D anatomy. PMID:18241813

  7. Rapid compressed sensing reconstruction of 3D non-Cartesian MRI.

    PubMed

    Baron, Corey A; Dwork, Nicholas; Pauly, John M; Nishimura, Dwight G

    2017-09-23

    Conventional non-Cartesian compressed sensing requires multiple nonuniform Fourier transforms every iteration, which is computationally expensive. Accordingly, time-consuming reconstructions have slowed the adoption of undersampled 3D non-Cartesian acquisitions into clinical protocols. In this work we investigate several approaches to minimize reconstruction times without sacrificing accuracy. The reconstruction problem can be reformatted to exploit the Toeplitz structure of matrices that are evaluated every iteration, but it requires larger oversampling than what is strictly required by nonuniform Fourier transforms. Accordingly, we investigate relative speeds of the two approaches for various nonuniform Fourier transform kernel sizes and oversampling for both GPU and CPU implementations. Second, we introduce a method to minimize matrix sizes by estimating the image support. Finally, density compensation weights have been used as a preconditioning matrix to improve convergence, but this increases noise. We propose a more general approach to preconditioning that allows a trade-off between accuracy and convergence speed. When using a GPU, the Toeplitz approach was faster for all practical parameters. Second, it was found that properly accounting for image support can prevent aliasing errors with minimal impact on reconstruction time. Third, the proposed preconditioning scheme improved convergence rates by an order of magnitude with negligible impact on noise. With the proposed methods, 3D non-Cartesian compressed sensing with clinically relevant reconstruction times (<2 min) is feasible using practical computer resources. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. PACS-based interface for 3D anatomical structure visualization and surgical planning

    NASA Astrophysics Data System (ADS)

    Koehl, Christophe; Soler, Luc; Marescaux, Jacques

    2002-05-01

    The interpretation of radiological image is routine but it remains a rather difficult task for physicians. It requires complex mental processes, that permit translation from 2D slices into 3D localization and volume determination of visible diseases. An easier and more extensive visualization and exploitation of medical images can be reached through the use of computer-based systems that provide real help from patient admission to post-operative followup. In this way, we have developed a 3D visualization interface linked to a PACS database that allows manipulation and interaction on virtual organs delineated from CT-scan or MRI. This software provides the 3D real-time surface rendering of anatomical structures, an accurate evaluation of volumes and distances and the improvement of radiological image analysis and exam annotation through a negatoscope tool. It also provides a tool for surgical planning allowing the positioning of an interactive laparoscopic instrument and the organ resection. The software system could revolutionize the field of computerized imaging technology. Indeed, it provides a handy and portable tool for pre-operative and intra-operative analysis of anatomy and pathology in various medical fields. This constitutes the first step of the future development of augmented reality and surgical simulation systems.

  9. Image segmentation and registration for the analysis of joint motion from 3D MRI

    NASA Astrophysics Data System (ADS)

    Hu, Yangqiu; Haynor, David R.; Fassbind, Michael; Rohr, Eric; Ledoux, William

    2006-03-01

    We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo MRI scans and its application to the analysis of ankle joint motion. Using an MR-compatible loading device, a foot was scanned in a single neutral and seven dynamic positions including maximal flexion, rotation and inversion/eversion. A segmentation method combining graph cuts and level sets was developed which allows a user to interactively delineate 14 bones in the neutral position volume in less than 30 minutes total, including less than 10 minutes of user interaction. In the subsequent registration step, a separate rigid body transformation for each bone is obtained by registering the neutral position dataset to each of the dynamic ones, which produces an accurate description of the motion between them. We have processed six datasets, including 3 normal and 3 pathological feet. For validation our results were compared with those obtained from 3DViewnix, a semi-automatic segmentation program, and achieved good agreement in volume overlap ratios (mean: 91.57%, standard deviation: 3.58%) for all bones. Our tool requires only 1/50 and 1/150 of the user interaction time required by 3DViewnix and NIH Image Plus, respectively, an improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications.

  10. Motion corrected 3D reconstruction of the fetal thorax from prenatal MRI.

    PubMed

    Kainz, Bernhard; Malamateniou, Christina; Murgasova, Maria; Keraudren, Kevin; Rutherford, Mary; Hajnal, Joseph V; Rueckert, Daniel

    2014-01-01

    In this paper we present a semi-automatic method for analysis of the fetal thorax in genuine three-dimensional volumes. After one initial click we localize the spine and accurately determine the volume of the fetal lung from high resolution volumetric images reconstructed from motion corrupted prenatal Magnetic Resonance Imaging (MRI). We compare the current state-of-the-art method of segmenting the lung in a slice-by-slice manner with the most recent multi-scan reconstruction methods. We use fast rotation invariant spherical harmonics image descriptors with Classification Forest ensemble learning methods to extract the spinal cord and show an efficient way to generate a segmentation prior for the fetal lung from this information for two different MRI field strengths. The spinal cord can be segmented with a DICE coefficient of 0.89 and the automatic lung segmentation has been evaluated with a DICE coefficient of 0.87. We evaluate our method on 29 fetuses with a gestational age (GA) between 20 and 38 weeks and show that our computed segmentations and the manual ground truth correlate well with the recorded values in literature.

  11. Rapid Isotropic 3D-Sodium MRI of the Knee Joint In-vivo at 7T

    PubMed Central

    Wang, Ligong; Wu, Yan; Chang, Gregory; Oesingmann, Niels; Schweitzer, Mark E.; Jerschow, Alexej; Regatte, Ravinder R.

    2009-01-01

    Purpose To demonstrate the feasibility of acquiring high resolution, isotropic 3D-sodium MR images of the whole knee joint in vivo at ultra high field strength (7.0T) via a 3D-radial acquisition with ultra short echo times and clinically acceptable acquisition times. Materials and Methods Five healthy controls (4 males, 1 female; mean ± standard deviation (SD) age 28.7 ± 4.8 years) and five patients with osteoarthritis (OA) (3 males, 2 females; mean ± SD age 52.4 ± 5.6 years) underwent 23Na–MRI on a 7T, multi-nuclei equipped whole body scanner. A quadrature 23Na knee coil and a 3D-gradient echo (GRE) imaging sequence with a radial acquisition were utilized. Cartilage sodium concentration was measured and compared between the healthy controls and OA patients. Results The average signal-to-noise ratio (SNR) for different spatial resolutions (1.2 mm – 4 mm) varied from ∼14 – 120, respectively. The mean sodium concentration of healthy subjects ranged from ∼240 ± 28 mM/L – 280 ± 22 mM/L. However, in OA patients the sodium concentrations were reduced, significantly by ∼30 – 60%, depending upon the degree of cartilage degeneration. Conclusion The preliminary results suggest that sodium imaging at 7T may be a feasible potential alternative for physiologic OA imaging and clinical diagnosis. PMID:19711406

  12. Automated 3D renal segmentation based on image partitioning

    NASA Astrophysics Data System (ADS)

    Yeghiazaryan, Varduhi; Voiculescu, Irina D.

    2016-03-01

    Despite several decades of research into segmentation techniques, automated medical image segmentation is barely usable in a clinical context, and still at vast user time expense. This paper illustrates unsupervised organ segmentation through the use of a novel automated labelling approximation algorithm followed by a hypersurface front propagation method. The approximation stage relies on a pre-computed image partition forest obtained directly from CT scan data. We have implemented all procedures to operate directly on 3D volumes, rather than slice-by-slice, because our algorithms are dimensionality-independent. The results picture segmentations which identify kidneys, but can easily be extrapolated to other body parts. Quantitative analysis of our automated segmentation compared against hand-segmented gold standards indicates an average Dice similarity coefficient of 90%. Results were obtained over volumes of CT data with 9 kidneys, computing both volume-based similarity measures (such as the Dice and Jaccard coefficients, true positive volume fraction) and size-based measures (such as the relative volume difference). The analysis considered both healthy and diseased kidneys, although extreme pathological cases were excluded from the overall count. Such cases are difficult to segment both manually and automatically due to the large amplitude of Hounsfield unit distribution in the scan, and the wide spread of the tumorous tissue inside the abdomen. In the case of kidneys that have maintained their shape, the similarity range lies around the values obtained for inter-operator variability. Whilst the procedure is fully automated, our tools also provide a light level of manual editing.

  13. Creation of 3D digital anthropomorphic phantoms which model actual patient non-rigid body motion as determined from MRI and position tracking studies of volunteers

    NASA Astrophysics Data System (ADS)

    Connolly, C. M.; Konik, A.; Dasari, P. K. R.; Segars, P.; Zheng, S.; Johnson, K. L.; Dey, J.; King, M. A.

    2011-03-01

    Patient motion can cause artifacts, which can lead to difficulty in interpretation. The purpose of this study is to create 3D digital anthropomorphic phantoms which model the location of the structures of the chest and upper abdomen of human volunteers undergoing a series of clinically relevant motions. The 3D anatomy is modeled using the XCAT phantom and based on MRI studies. The NURBS surfaces of the XCAT are interactively adapted to fit the MRI studies. A detailed XCAT phantom is first developed from an EKG triggered Navigator acquisition composed of sagittal slices with a 3 x 3 x 3 mm voxel dimension. Rigid body motion states are then acquired at breath-hold as sagittal slices partially covering the thorax, centered on the heart, with 9 mm gaps between them. For non-rigid body motion requiring greater sampling, modified Navigator sequences covering the entire thorax with 3 mm gaps between slices are obtained. The structures of the initial XCAT are then adapted to fit these different motion states. Simultaneous to MRI imaging the positions of multiple reflective markers on stretchy bands about the volunteer's chest and abdomen are optically tracked in 3D via stereo imaging. These phantoms with combined position tracking will be used to investigate both imaging-data-driven and motion-tracking strategies to estimate and correct for patient motion. Our initial application will be to cardiacperfusion SPECT imaging where the XCAT phantoms will be used to create patient activity and attenuation distributions for each volunteer with corresponding motion tracking data from the markers on the body-surface. Monte Carlo methods will then be used to simulate SPECT acquisitions, which will be used to evaluate various motion estimation and correction strategies.

  14. Evaluation of sub-voxel registration accuracy between MRI and 3D MR spectroscopy of the brain

    NASA Astrophysics Data System (ADS)

    Rousseau, Francois; Maudsley, Andrew; Ebel, Andreas; Darkazanli, Ammar; Weber, Patrice; Sivasankaran, Krishnakumar; Yu, Yingjian; Studholme, Colin

    2005-04-01

    The implementation of Magnetic Resonance Spectroscopic Imaging (MRSI) for diagnostic imaging benefits from close integration of the lower-spatial resolution MRSI information with information from high-resolution structural MRI. Since patients can commonly move between acquisitions, it is necessary to account for possible mis-registration between the datasets arising from differences in patient positioning. In this paper we evaluate the use of 4 common multi-modality registration criteria to recover alignment between high resolution structural MRI and 3D MRSI data of the brain with sub-voxel accuracy. We explore the use of alternative MRSI water reference images to provide different types of structural information for the alignment process. The alignment accuracy was evaluated using both synthetically created MRSI and MRI data and a set of carefully collected subject image data with known ground truth spatial transformation between image volumes. The final accuracy and precision of estimates were assessed using multiple random starts of the registration algorithm. Sub voxel accuracy was found by all four similarity criteria with normalized mutual information providing the lowest target registration error for the 7 subject images. This effort supports the ongoing development of a database of brain metabolite distributions in normal subjects, which will be used in the evaluation of metabolic changes in neurological diseases.

  15. Sparse Bayesian framework applied to 3D super-resolution reconstruction in fetal brain MRI

    NASA Astrophysics Data System (ADS)

    Becerra, Laura C.; Velasco Toledo, Nelson; Romero Castro, Eduardo

    2015-01-01

    Fetal Magnetic Resonance (FMR) is an imaging technique that is becoming increasingly important as allows assessing brain development and thus make an early diagnostic of congenital abnormalities, spatial resolution is limited by the short acquisition time and the unpredictable fetus movements, in consequence the resulting images are characterized by non-parallel projection planes composed by anisotropic voxels. The sparse Bayesian representation is a flexible strategy which is able to model complex relationships. The Super-resolution is approached as a regression problem, the main advantage is the capability to learn data relations from observations. Quantitative performance evaluation was carried out using synthetic images, the proposed method demonstrates a better reconstruction quality compared with standard interpolation approach. The presented method is a promising approach to improve the information quality related with the 3-D fetal brain structure. It is important because allows assessing brain development and thus make an early diagnostic of congenital abnormalities.

  16. A Novel Multiparametric Approach to 3D Quantitative MRI of the Brain.

    PubMed

    Palma, Giuseppe; Tedeschi, Enrico; Borrelli, Pasquale; Cocozza, Sirio; Russo, Carmela; Liu, Saifeng; Ye, Yongquan; Comerci, Marco; Alfano, Bruno; Salvatore, Marco; Haacke, E Mark; Mancini, Marcello

    2015-01-01

    Magnetic Resonance properties of tissues can be quantified in several respects: relaxation processes, density of imaged nuclei, magnetism of environmental molecules, etc. In this paper, we propose a new comprehensive approach to obtain 3D high resolution quantitative maps of arbitrary body districts, mainly focusing on the brain. The theory presented makes it possible to map longitudinal (R1), pure transverse (R2) and free induction decay ([Formula: see text]) rates, along with proton density (PD) and magnetic susceptibility (χ), from a set of fast acquisition sequences in steady-state that are highly insensitive to flow phenomena. A novel denoising scheme is described and applied to the acquired datasets to enhance the signal to noise ratio of the derived maps and an information theory approach compensates for biases from radio frequency (RF) inhomogeneities, if no direct measure of the RF field is available. Finally, the results obtained on sample brain scans of healthy controls and multiple sclerosis patients are presented and discussed.

  17. Computation of a high-resolution MRI 3D stereotaxic atlas of the sheep brain.

    PubMed

    Ella, Arsène; Delgadillo, José A; Chemineau, Philippe; Keller, Matthieu

    2017-02-15

    The sheep model was first used in the fields of animal reproduction and veterinary sciences and then was utilized in fundamental and preclinical studies. For more than a decade, magnetic resonance (MR) studies performed on this model have been increasingly reported, especially in the field of neuroscience. To contribute to MR translational neuroscience research, a brain template and an atlas are necessary. We have recently generated the first complete T1-weighted (T1W) and T2W MR population average images (or templates) of in vivo sheep brains. In this study, we 1) defined a 3D stereotaxic coordinate system for previously established in vivo population average templates; 2) used deformation fields obtained during optimized nonlinear registrations to compute nonlinear tissues or prior probability maps (nlTPMs) of cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM) tissues; 3) delineated 25 external and 28 internal sheep brain structures by segmenting both templates and nlTPMs; and 4) annotated and labeled these structures using an existing histological atlas. We built a quality high-resolution 3D atlas of average in vivo sheep brains linked to a reference stereotaxic space. The atlas and nlTPMs, associated with previously computed T1W and T2W in vivo sheep brain templates and nlTPMs, provide a complete set of imaging space that are able to be imported into other imaging software programs and could be used as standardized tools for neuroimaging studies or other neuroscience methods, such as image registration, image segmentation, identification of brain structures, implementation of recording devices, or neuronavigation. J. Comp. Neurol. 525:676-692, 2017. © 2016 Wiley Periodicals, Inc.

  18. A Simple Quality Assessment Index for Stereoscopic Images Based on 3D Gradient Magnitude

    PubMed Central

    Wang, Shanshan; Shao, Feng; Li, Fucui; Yu, Mei; Jiang, Gangyi

    2014-01-01

    We present a simple quality assessment index for stereoscopic images based on 3D gradient magnitude. To be more specific, we construct 3D volume from the stereoscopic images across different disparity spaces and calculate pointwise 3D gradient magnitude similarity (3D-GMS) along three horizontal, vertical, and viewpoint directions. Then, the quality score is obtained by averaging the 3D-GMS scores of all points in the 3D volume. Experimental results on four publicly available 3D image quality assessment databases demonstrate that, in comparison with the most related existing methods, the devised algorithm achieves high consistency alignment with subjective assessment. PMID:25133265

  19. 3-dimensional (3D) fabricated polymer based drug delivery systems.

    PubMed

    Moulton, Simon E; Wallace, Gordon G

    2014-11-10

    Drug delivery from 3-dimensional (3D) structures is a rapidly growing area of research. It is essential to achieve structures wherein drug stability is ensured, the drug loading capacity is appropriate and the desired controlled release profile can be attained. Attention must also be paid to the development of appropriate fabrication machinery that allows 3D drug delivery systems (DDS) to be produced in a simple, reliable and reproducible manner. The range of fabrication methods currently being used to form 3D DDSs include electrospinning (solution and melt), wet-spinning and printing (3-dimensional). The use of these techniques enables production of DDSs from the macro-scale down to the nano-scale. This article reviews progress in these fabrication techniques to form DDSs that possess desirable drug delivery kinetics for a wide range of applications.

  20. Collaboration on Scene Graph Based 3D Data

    NASA Astrophysics Data System (ADS)

    Ammon, Lorenz; Bieri, Hanspeter

    Professional 3D digital content creation tools, like Alias Maya or discreet 3ds max, offer only limited support for a team of artists to work on a 3D model collaboratively. We present a scene graph repository system that enables fine-grained collaboration on scenes built using standard 3D DCC tools by applying the concept of collaborative versions to a general attributed scene graph. Artists can work on the same scene in parallel without locking out each other. The artists' changes to a scene are regularly merged to ensure that all artists can see each others progress and collaborate on current data. We introduce the concept of indirect changes and indirect conflicts to systematically inspect the effects that collaborative changes have on a scene. Inspecting indirect conflicts helps maintaining scene consistency by systematically looking for inconsistencies at the right places.

  1. Validation of optical codes based on 3D nanostructures

    NASA Astrophysics Data System (ADS)

    Carnicer, Artur; Javidi, Bahram

    2017-05-01

    Image information encoding using random phase masks produce speckle-like noise distributions when the sample is propagated in the Fresnel domain. As a result, information cannot be accessed by simple visual inspection. Phase masks can be easily implemented in practice by attaching cello-tape to the plain-text message. Conventional 2D-phase masks can be generalized to 3D by combining glass and diffusers resulting in a more complex, physical unclonable function. In this communication, we model the behavior of a 3D phase mask using a simple approach: light is propagated trough glass using the angular spectrum of plane waves whereas the diffusor is described as a random phase mask and a blurring effect on the amplitude of the propagated wave. Using different designs for the 3D phase mask and multiple samples, we demonstrate that classification is possible using the k-nearest neighbors and random forests machine learning algorithms.

  2. Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions

    PubMed Central

    Park, Yong-Lae; Elayaperumal, Santhi; Daniel, Bruce; Ryu, Seok Chang; Shin, Mihye; Savall, Joan; Black, Richard J.; Moslehi, Behzad; Cutkosky, Mark R.

    2015-01-01

    We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-μm-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner. PMID:26405428

  3. Axisymmetric Implementation for 3D-Based DSMC Codes

    NASA Technical Reports Server (NTRS)

    Stewart, Benedicte; Lumpkin, F. E.; LeBeau, G. J.

    2011-01-01

    The primary objective in developing NASA s DSMC Analysis Code (DAC) was to provide a high fidelity modeling tool for 3D rarefied flows such as vacuum plume impingement and hypersonic re-entry flows [1]. The initial implementation has been expanded over time to offer other capabilities including a novel axisymmetric implementation. Because of the inherently 3D nature of DAC, this axisymmetric implementation uses a 3D Cartesian domain and 3D surfaces. Molecules are moved in all three dimensions but their movements are limited by physical walls to a small wedge centered on the plane of symmetry (Figure 1). Unfortunately, far from the axis of symmetry, the cell size in the direction perpendicular to the plane of symmetry (the Z-direction) may become large compared to the flow mean free path. This frequently results in inaccuracies in these regions of the domain. A new axisymmetric implementation is presented which aims to solve this issue by using Bird s approach for the molecular movement while preserving the 3D nature of the DAC software [2]. First, the computational domain is similar to that previously used such that a wedge must still be used to define the inflow surface and solid walls within the domain. As before molecules are created inside the inflow wedge triangles but they are now rotated back to the symmetry plane. During the move step, molecules are moved in 3D but instead of interacting with the wedge walls, the molecules are rotated back to the plane of symmetry at the end of the move step. This new implementation was tested for multiple flows over axisymmetric shapes, including a sphere, a cone, a double cone and a hollow cylinder. Comparisons to previous DSMC solutions and experiments, when available, are made.

  4. Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo.

    PubMed

    Jung, Jee Young; Yoon, Young Cheol; Jung, Jin Young; Choe, Bong-Keun

    2013-04-01

    Isotropic three-dimensional (3D) magnetic resonance imaging (MRI) has been applied to various joints. However, comparison for image quality between isotropic 3D MRI and two-dimensional (2D) turbo spin echo (TSE) sequence of the wrist at a 3T MR system has not been investigated. To compare the image quality of isotropic 3D MRI including TSE intermediate-weighted (VISTA) sequence and fast field echo (FFE) sequence with 2D TSE intermediate-weighted sequence of the wrist joint at 3.0 T. MRI was performed in 10 wrists of 10 healthy volunteers with isotropic 3D sequences (VISTA and FFE) and 2D TSE intermediate-weighted sequences at 3.0 T. The signal-to-noise ratio (SNR) was obtained by imaging phantom and noise-only image. Contrast ratios (CRs) were calculated between fluid and cartilage, triangular fibrocartilage complex (TFCC), and the scapholunate ligament. Two radiologists independently assessed the visibility of TFCC, carpal ligaments, cartilage, tendons and nerves with a four-point grading scale. Statistical analysis to compare CRs (one way ANOVA with a Tukey test) and grades of visibility (Kruskal-Wallis test) between three sequences and those for inter-observer agreement (kappa analysis) were performed. The SNR of 2D TSE (46.26) was higher than those of VISTA (23.34) and 3D FFE (19.41). CRs were superior in 2D TSE than VISTA (P = 0.02) for fluid-cartilage and in 2D TSE than 3D FFE (P < 0.01) for fluid-TFCC. The visibility was best in 2D TSE (P < 0.01) for TFCC and in VISTA (P = 0.01) for scapholunate ligament. The visibility was better in 2D TSE and 3D FFE (P = 0.04) for cartilage and in VISTA than 3D FFE (P < 0.01) for TFCC. The inter-observer agreement for the visibility of anatomic structures was moderate or substantial. Image quality of 2D TSE was superior to isotropic 3D MR imaging for cartilage, and TFCC. 3D FFE has better visibility for cartilage than VISTA and VISTA has superior visibility for TFCC to 3D FFE and the visibility for scapholunate ligament

  5. Microseismic network design assessment based on 3D ray tracing

    NASA Astrophysics Data System (ADS)

    Näsholm, Sven Peter; Wuestefeld, Andreas; Lubrano-Lavadera, Paul; Lang, Dominik; Kaschwich, Tina; Oye, Volker

    2016-04-01

    There is increasing demand on the versatility of microseismic monitoring networks. In early projects, being able to locate any triggers was considered a success. These early successes led to a better understanding of how to extract value from microseismic results. Today operators, regulators, and service providers work closely together in order to find the optimum network design to meet various requirements. In the current study we demonstrate an integrated and streamlined network capability assessment approach. It is intended for use during the microseismic network design process prior to installation. The assessments are derived from 3D ray tracing between a grid of event points and the sensors. Three aspects are discussed: 1) Magnitude of completeness or detection limit; 2) Event location accuracy; and 3) Ground-motion hazard. The network capability parameters 1) and 2) are estimated at all hypothetic event locations and are presented in the form of maps given a seismic sensor coordinate scenario. In addition, the ray tracing traveltimes permit to estimate the point-spread-functions (PSFs) at the event grid points. PSFs are useful in assessing the resolution and focusing capability of the network for stacking-based event location and imaging methods. We estimate the performance for a hypothetical network case with 11 sensors. We consider the well-documented region around the San Andreas Fault Observatory at Depth (SAFOD) located north of Parkfield, California. The ray tracing is done through a detailed velocity model which covers a 26.2 by 21.2 km wide area around the SAFOD drill site with a resolution of 200 m both for the P-and S-wave velocities. Systematic network capability assessment for different sensor site scenarios prior to installation facilitates finding a final design which meets the survey objectives.

  6. 3D Clumped Cell Segmentation Using Curvature Based Seeded Watershed

    PubMed Central

    Atta-Fosu, Thomas; Guo, Weihong; Jeter, Dana; Mizutani, Claudia M.; Stopczynski, Nathan; Sousa-Neves, Rui

    2017-01-01

    Image segmentation is an important process that separates objects from the background and also from each other. Applied to cells, the results can be used for cell counting which is very important in medical diagnosis and treatment, and biological research that is often used by scientists and medical practitioners. Segmenting 3D confocal microscopy images containing cells of different shapes and sizes is still challenging as the nuclei are closely packed. The watershed transform provides an efficient tool in segmenting such nuclei provided a reasonable set of markers can be found in the image. In the presence of low-contrast variation or excessive noise in the given image, the watershed transform leads to over-segmentation (a single object is overly split into multiple objects). The traditional watershed uses the local minima of the input image and will characteristically find multiple minima in one object unless they are specified (marker-controlled watershed). An alternative to using the local minima is by a supervised technique called seeded watershed, which supplies single seeds to replace the minima for the objects. Consequently, the accuracy of a seeded watershed algorithm relies on the accuracy of the predefined seeds. In this paper, we present a segmentation approach based on the geometric morphological properties of the ‘landscape’ using curvatures. The curvatures are computed as the eigenvalues of the Shape matrix, producing accurate seeds that also inherit the original shape of their respective cells. We compare with some popular approaches and show the advantage of the proposed method. PMID:28280723

  7. Knowledge-Based Analysis And Understanding Of 3D Medical Images

    NASA Astrophysics Data System (ADS)

    Dhawan, Atam P.; Juvvadi, Sridhar

    1988-06-01

    The anatomical three-dimensional (3D) medical imaging modalities, such as X-ray CT and MRI, have been well recognized in the diagnostic radiology for several years while the nuclear medicine modalities, such as PET, have just started making a strong impact through functional imaging. Though PET images provide the functional information about the human organs, they are hard to interpret because of the lack of anatomical information. Our objective is to develop a knowledge-based biomedical image analysis system which can interpret the anatomical images (such as CT). The anatomical information thus obtained can then be used in analyzing PET images of the same patient. This will not only help in interpreting PET images but it will also provide a means of studying the correlation between the anatomical and functional imaging. This paper presents the preliminary results of the knowledge based biomedical image analysis system for interpreting CT images of the chest.

  8. Mechanics of the ankle and subtalar joints revealed through a 3D quasi-static stress MRI technique.

    PubMed

    Siegler, S; Udupa, J K; Ringleb, S I; Imhauser, C W; Hirsch, B E; Odhner, D; Saha, P K; Okereke, E; Roach, N

    2005-03-01

    A technique to study the three-dimensional (3D) mechanical characteristics of the ankle and of the subtalar joints in vivo and in vitro is described. The technique uses an MR scanner compatible 3D positioning and loading linkage to load the hindfoot with precise loads while the foot is being scanned. 3D image processing algorithms are used to derive from the acquired MR images bone morphology, hindfoot architecture, and joint kinematics. The technique was employed to study these properties both in vitro and in vivo. The ankle and subtler joint motion and the changes in architecture produced in response to an inversion load and an anterior drawer load were evaluated. The technique was shown to provide reliable measures of bone morphology. The left-to-right variations in bone morphology were less than 5%. The left-to-right variations in unloaded hindfoot architecture parameters were less than 10%, and these properties were only slightly affected by inversion and anterior drawer loads. Inversion and anterior drawer loads produced motion both at the ankle and at the subtalar joint. In addition, high degree of coupling, primarily of internal rotation with inversion, was observed both at the ankle and at the subtalar joint. The in vitro motion produced in response to inversion and anterior drawer load was greater than the in vivo motion. Finally, external motion, measured directly across the ankle complex, produced in response to load was much greater than the bone movements measured through the 3D stress MRI technique indicating the significant effect of soft tissue and skin interference.

  9. Does breast MRI background parenchymal enhancement indicate metabolic activity? Qualitative and 3D quantitative computer imaging analysis.

    PubMed

    Mema, Eralda; Mango, Victoria L; Guo, Xiaotao; Karcich, Jenika; Yeh, Randy; Wynn, Ralph T; Zhao, Binsheng; Ha, Richard S

    2017-06-24

    To investigate whether the degree of breast magnetic resonance imaging (MRI) background parenchymal enhancement (BPE) is associated with the amount of breast metabolic activity measured by breast parenchymal uptake (BPU) of 18F-FDG on positron emission tomography / computed tomography (PET/CT). An Institutional Review Board (IRB)-approved retrospective study was performed. Of 327 patients who underwent preoperative breast MRI from 1/1/12 to 12/31/15, 73 patients had 18F-FDG PET/CT evaluation performed within 1 week of breast MRI and no suspicious findings in the contralateral breast. MRI was performed on a 1.5T or 3.0T system. The imaging sequence included a triplane localizing sequence followed by sagittal fat-suppressed T2 -weighted sequence, and a bilateral sagittal T1 -weighted fat-suppressed fast spoiled gradient-echo sequence, which was performed before and three times after a rapid bolus injection (gadobenate dimeglumine, Multihance; Bracco Imaging; 0.1 mmol/kg) delivered through an IV catheter. The unaffected contralateral breast in these 73 patients underwent BPE and BPU assessments. For PET/CT BPU calculation, a 3D region of interest (ROI) was drawn around the glandular breast tissue and the maximum standardized uptake value (SUVmax ) was determined. Qualitative MRI BPE assessments were performed on a 4-point scale, in accordance with BI-RADS categories. Additional 3D quantitative MRI BPE analysis was performed using a previously published in-house technique. Spearman's correlation test and linear regression analysis was performed (SPSS, v. 24). The median time interval between breast MRI and 18F-FDG PET/CT evaluation was 3 days (range, 0-6 days). BPU SUVmax mean value was 1.6 (SD, 0.53). Minimum and maximum BPU SUVmax values were 0.71 and 4.0. The BPU SUVmax values significantly correlated with both the qualitative and quantitative measurements of BPE, respectively (r(71) = 0.59, P < 0.001 and r(71) = 0.54, P < 0.001). Qualitatively assessed high

  10. Use of 3-D MRI to Diagnose Unilateral Cervical Atresia in Obstructive Hemivagina with Ipsilateral Renal Anomaly (OHVIRA): A Case Report and Review of the Literature.

    PubMed

    Tomlin, Kristl; Barnes, Craig; Van Leeuwen, Kathy; Williamson, Amy

    2017-07-28

    Congenital atresia of the cervix in the setting of an obstructed hemivagina with ipsilateral renal anomaly (OHVIRA) is an unusual occurrence which is frequently missed by preoperative imaging modalities. A 14 year-old adolescent female presented to a tertiary-care facility with abdominal pain associated with a mass. Initial imaging with ultrasound and MRI (magnetic resonance imaging) suggested OHVIRA but a 3-D MRI also correctly identified unilateral cervical atresia on the obstructed left side. 3-D MRI in the setting of OHVIRA was used successfully in this case to preoperatively identify cervical atresia and to guide preoperative surgical counseling and planning. The use of 3-D MRI for this purpose has never been described in the literature. Copyright © 2017. Published by Elsevier Inc.

  11. Seeing biological actions in 3D: An fMRI study

    PubMed Central

    Jastorff, Jan; Abdollahi, Rouhollah O.; Fasano, Fabrizio

    2015-01-01

    Abstract Precise kinematics or body configuration cannot be recovered from visual input without disparity information. Yet, no imaging study has investigated the role of disparity on action observation. Here, we investigated the interaction between disparity and the main cues of biological motion, kinematics and configuration, in two fMRI experiments. Stimuli were presented as point‐light figures, depicting complex action sequences lasting 21 s. We hypothesized that interactions could occur at any of the three levels of the action observation network, comprising occipitotemporal, parietal and premotor cortex, with premotor cortex being the most likely location. The main effects of kinematics and configuration confirmed that the biological motion sequences activated all three levels of the action observation network, validating our approach. The interaction between configuration and disparity activated only premotor cortex, whereas interactions between kinematics and disparity occurred at all levels of the action observation network but were strongest at the premotor level. Control experiments demonstrated that these interactions could not be accounted for by low level motion in depth, task effects, spatial attention, or eye movements, including vergence. These results underscore the role of premotor cortex in action observation, and in imitating others or responding to their actions. Hum Brain Mapp 37:203–219, 2016. © 2015 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc. PMID:26510637

  12. A practical and flexible implementation of 3D MRI in the Earth's magnetic field.

    PubMed

    Halse, Meghan E; Coy, Andrew; Dykstra, Robin; Eccles, Craig; Hunter, Mark; Ward, Rob; Callaghan, Paul T

    2006-09-01

    The Earth's magnetic field, though weak, is appealing for NMR applications because it is highly homogeneous, globally available and free. However, the practicality of Earth's field NMR (EFNMR) has long been limited by the need to perform experiments in outdoor locations where the local field homogeneity is not disrupted by ferrous or magnetic objects and where ultra-low frequency (ULF) noise sources are at a minimum. Herein we present a flexible and practical implementation of MRI in the Earth's magnetic field that demonstrates that EFNMR is not as difficult as it was previously thought to be. In this implementation, pre-polarization and ULF noise shielding, achieved using a crude electromagnet, are used to significantly improve signal-to-noise ratio (SNR) even in relatively noisy environments. A three axis gradient coil set, in addition to providing imaging gradients, is used to provide first-order shims such that sub-hertz linewidths can routinely be achieved, even in locations of significant local field inhomogeneity such as indoor scientific laboratories. Temporal fluctuations in the magnitude of the Earth's magnetic field are measured and a regime found within which these variations in Larmor frequency produce no observable artefacts in reconstructed images.

  13. Patient-specific respiratory models using dynamic 3D MRI: preliminary volunteer results.

    PubMed

    Miquel, M E; Blackall, J M; Uribe, S; Hawkes, D J; Schaeffter, T

    2013-03-01

    Organ and tumour motion has a significant impact on the planning and delivery of radiotherapy treatment. At present imaging modality such as four-dimensional computer tomography (4DCT) cannot be used to measure the variability of motion between different respiratory cycles. To create reliable motion models, one needs to acquire volumetric data sets of the lungs with sufficient sampling of the breathing cycle. In this paper we investigate the use of highly parallel MRI to acquire such data. A 32 channel coil in conjunction with a balanced SSFP sequence and a SENSE factor of 6 were used to acquire volumetric data sets in five healthy volunteers. The acquisition was repeated for seven series of different breathing patterns. The data acquired was of sufficient spatial resolution (5 × 5 × 5 mm(3)) and image quality to carry out automated non-rigid registration. The acquisition rate (c.a. 2 volumes per second) allowed for a meaningful sampling of the different respiratory curves that were automatically obtained from the skin surface motion. This acquisition technique should provide images of high enough quality to create statistical respiratory models.

  14. Machine learning-based 3-D geometry reconstruction and modeling of aortic valve deformation using 3-D computed tomography images.

    PubMed

    Liang, Liang; Kong, Fanwei; Martin, Caitlin; Pham, Thuy; Wang, Qian; Duncan, James; Sun, Wei

    2017-05-01

    To conduct a patient-specific computational modeling of the aortic valve, 3-D aortic valve anatomic geometries of an individual patient need to be reconstructed from clinical 3-D cardiac images. Currently, most of computational studies involve manual heart valve geometry reconstruction and manual finite element (FE) model generation, which is both time-consuming and prone to human errors. A seamless computational modeling framework, which can automate this process based on machine learning algorithms, is desirable, as it can not only eliminate human errors and ensure the consistency of the modeling results but also allow fast feedback to clinicians and permits a future population-based probabilistic analysis of large patient cohorts. In this study, we developed a novel computational modeling method to automatically reconstruct the 3-D geometries of the aortic valve from computed tomographic images. The reconstructed valve geometries have built-in mesh correspondence, which bridges harmonically for the consequent FE modeling. The proposed method was evaluated by comparing the reconstructed geometries from 10 patients with those manually created by human experts, and a mean discrepancy of 0.69 mm was obtained. Based on these reconstructed geometries, FE models of valve leaflets were developed, and aortic valve closure from end systole to middiastole was simulated for 7 patients and validated by comparing the deformed geometries with those manually created by human experts, and a mean discrepancy of 1.57 mm was obtained. The proposed method offers great potential to streamline the computational modeling process and enables the development of a preoperative planning system for aortic valve disease diagnosis and treatment. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Multiscan MRI-based virtual cystoscopy

    NASA Astrophysics Data System (ADS)

    Chen, Dongqing; Li, Bin; Huang, Wei; Liang, Zach

    2000-04-01

    Computed tomography (CT) based virtual cystoscopy (VC) has been studied as a potential tool for screening bladder cancer. It is accurate in localizing tumor of size larger than 1 cm and less expensive, as compared to fiberoptic cystoscopy. However, it is invasive and difficult to perform due to using Foley catheter for bladder insufflating with air. In a previous work, we investigated a magnetic resonance imaging (MRI) based VC scheme with urine as a natural contrast solution, in which a MRI acquisition protocol and an adaptive segmentation method were utilized. Both bladder lumen and wall were successfully delineated. To suppress motion artifact and insight pathological change on the bladder wall images, a multi-scan MRI scheme was presented in this study. One transverse and another coronal acquisitions of T1-weighted that cover the whole bladder were obtained twice, at one time the bladder is full of urine and at another time it is near the empty. Four bladder volumes extracted from those 4 datasets were registered first using a flexible three- dimensional (3D) registration algorithm. Then, associated 4 lumen surfaces were viewed simultaneously with the help of an interactive 3D visualization system. This MRI-based VC was tested on volunteers and demonstrated the feasibility to mass screening for bladder cancer.

  16. New normoxic N-(Hydroxymethyl)acrylamide based polymer gel for 3D dosimetry in radiation therapy.

    PubMed

    Rabaeh, Khalid A; Basfar, Ahmed A; Almousa, Akram A; Devic, Slobodan; Moftah, Belal

    2017-01-01

    A novel composition of normoxic polymer gel dosimeters based on radiation-induced polymerization of N-(Hydroxymethyl)acrylamide (NHMA) is introduced in this study for 3D dosimetry for Quality Assurance (QA) in radiation therapy. Dosimeters were irradiated by 6, 10 and 18MV photon beams of a medical linear accelerator at various dose rates to doses of up to 20Gy. The dose response of polymer gel dosimeters was studied using nuclear magnetic resonance (NMR) spin-spin relaxation rate (R2) of hydrogen protons within the water molecule. Also, we measured gel response using absorption spectroscopy and found that this novel gel can be successfully utilized for both MRI- and OCT- (Optical Computed Tomography) based 3D dosimetry. We investigated dosimetric properties of six different compositions of the new NHMA-based gel in terms of dose rate, radiation beam quality and stability of dose-dependent polymerization after irradiation. We found no significant effects of these parameters on the novel gel dosimeter performance in both relaxation rate and absorbance measurements.

  17. Mesh Generation and Microstructure Extraction based on 3D Porous Medium Images

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Xing, H.; Guan, Z.

    2009-12-01

    With the development of SEM and/or MRI based techniques, it is increasingly easy to get the high quality 3D images of porous medium with the microscopic structure information. Once the pixel information for a block of porous medium is obtained, a point array description for this porous medium is defined, and both coordination and material property information are included. To analyze such related data and apply them into the further numerical modeling, a mesh generator is developed. It has following steps: (1) Reading data from a 3D image with material property/microstructure information and extracting points with the specified material property; (2) Performing a well-known Delaunay triangulation on the related points and constraining the boundary of different materials; (3) Extracting boundary which describes the microscopic structure of porous medium; (4) Smoothing boundary based on Curvature and shape of the porous medium including mesh coarsening/refining. (5) Using the smoothed boundary as an input closed triangular surface and taking a constrained Delaunay triangulation based on this surface; (6) Adaptively refining the generated tetrahedron and transporting the property of porous medium to the related tetrahedrons; (7) Output the mesh for the further numerical (e.g. FEM, FDM, FVM) analysis.

  18. Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

    SciTech Connect

    Boye, Dirk; Lomax, Tony; Knopf, Antje

    2013-06-15

    Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a 'snap-shot' of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT(MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on

  19. Fast calculation of computer-generated holograms based on 3-D Fourier spectrum for omnidirectional diffraction from a 3-D voxel-based object.

    PubMed

    Sando, Yusuke; Barada, Daisuke; Yatagai, Toyohiko

    2012-09-10

    We have derived the basic spectral relation between a 3-D object and its 2-D diffracted wavefront by interpreting the diffraction calculation in the 3-D Fourier domain. Information on the 3-D object, which is inherent in the diffracted wavefront, becomes clear by using this relation. After the derivation, a method for obtaining the Fourier spectrum that is required to synthesize a hologram with a realistic sampling number for visible light is described. Finally, to verify the validity and the practicality of the above-mentioned spectral relation, fast calculation of a series of wavefronts radially diffracted from a 3-D voxel-based object is demonstrated.

  20. Human vocal tract analysis by in vivo 3D MRI during phonation: a complete system for imaging, quantitative modeling, and speech synthesis.

    PubMed

    Wismueller, Axel; Behrends, Johannes; Hoole, Phil; Leinsinger, Gerda L; Reiser, Maximilian F; Westesson, Per-Lennart

    2008-01-01

    We present a complete system for image-based 3D vocal tract analysis ranging from MR image acquisition during phonation, semi-automatic image processing, quantitative modeling including model-based speech synthesis, to quantitative model evaluation by comparison between recorded and synthesized phoneme sounds. For this purpose, six professionally trained speakers, age 22-34y, were examined using a standardized MRI protocol (1.5 T, T1w FLASH, ST 4mm, 23 slices, acq. time 21s). The volunteers performed a prolonged (> or = 21s) emission of sounds of the German phonemic inventory. Simultaneous audio tape recording was obtained to control correct utterance. Scans were made in axial, coronal, and sagittal planes each. Computer-aided quantitative 3D evaluation included (i) automated registration of the phoneme-specific data acquired in different slice orientations, (ii) semi-automated segmentation of oropharyngeal structures, (iii) computation of a curvilinear vocal tract midline in 3D by nonlinear PCA, (iv) computation of cross-sectional areas of the vocal tract perpendicular to this midline. For the vowels /a/,/e/,/i/,/o/,/ø/,/u/,/y/, the extracted area functions were used to synthesize phoneme sounds based on an articulatory-acoustic model. For quantitative analysis, recorded and synthesized phonemes were compared, where area functions extracted from 2D midsagittal slices were used as a reference. All vowels could be identified correctly based on the synthesized phoneme sounds. The comparison between synthesized and recorded vowel phonemes revealed that the quality of phoneme sound synthesis was improved for phonemes /a/, /o/, and /y/, if 3D instead of 2D data were used, as measured by the average relative frequency shift between recorded and synthesized vowel formants (p < 0.05, one-sided Wilcoxon rank sum test). In summary, the combination of fast MRI followed by subsequent 3D segmentation and analysis is a novel approach to examine human phonation in vivo. It

  1. Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy.

    PubMed

    Saxena, Vishal; Anari, Jason B; Ruutiainen, Alexander T; Voleti, Pramod B; Stephenson, Jason W; Lee, Gwo-Chin

    2016-08-01

    Restoration of normal anatomy and proper ligament balance are theoretical prerequisites for reproducing physiological kinematics with bicruciate-retaining total knee arthroplasty (TKA). The purpose of this study was to use a 3D MRI technique to evaluate the topography of the proximal tibia and outline considerations in tibial component design for bicruciate-retaining TKA. We identified 100 consecutive patients (50 males and 50 females) between ages 20 and 40 years with knee MRIs without arthritis, dysplasia, ACL tears, or prior knee surgery. A novel 3D MRI protocol coordinating axial, coronal, and sagittal images was used to measure: 1) medial and lateral posterior tibial slopes; 2) medial and lateral coronal slopes; and 3) distance from the anterior tibia to the ACL footprint. There was no overall difference in medial and lateral posterior tibial slopes (5.5° (95% CI 5.0 to 6.0°) vs. 5.4° (95% CI 4.8 to 6.0°), respectively (p=0.80)), but 41 patients had side-to-side differences greater than 3°. The medial coronal slope was greater than the lateral coronal slope (4.6° (95% CI 4.0 to 5.1°) vs. 3.3° (95% CI 2.9 to 3.7°), respectively (p<0.0001)). Females had less clearance between the anterior tibia and ACL footprint than males (10.8mm (95% CI 10.4 to 11.2mm) vs. 13.0mm (95% CI 12.5 to 13.5mm), respectively (p<0.0001)). Due to highly variable proximal tibial topography, a monoblock bicruciate-retaining tibial baseplate may not reproduce normal anatomy in all patients. Level IV - Anatomic research study. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Target penetration of laser-based 3D imaging systems

    NASA Astrophysics Data System (ADS)

    Cheok, Geraldine S.; Saidi, Kamel S.; Franaszek, Marek

    2009-01-01

    The ASTM E57.02 Test Methods Subcommittee is developing a test method to evaluate the ranging performance of a 3D imaging system. The test method will involve either measuring the distance between two targets or between an instrument and a target. The first option is necessary because some instruments cannot be centered over a point and will require registration of the instrument coordinate frame into the target coordinate frame. The disadvantage of this option is that registration will introduce an additional error into the measurements. The advantage of this option is that this type of measurement, relative measurement, is what is typically used in field applications. A potential target geometry suggested for the test method is a planar target. The ideal target material would be diffuse, have uniform reflectivity for wavelengths between 500 nm to 1600 nm (wavelengths of most commercially-available 3D imaging systems), and have minimal or no penetration of the laser into the material. A possible candidate material for the target is Spectralon1. However, several users have found that there is some penetration into the Spectralon by a laser and this is confirmed by the material manufacturer. The effect of this penetration on the range measurement is unknown. This paper will present an attempt to quantify the laser penetration depth into the Spectralon material for four 3D imaging systems.

  3. 3D and 4D magnetic susceptibility tomography based on complex MR images

    DOEpatents

    Chen, Zikuan; Calhoun, Vince D

    2014-11-11

    Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

  4. Cartilage segmentation of 3D MRI scans of the osteoarthritic knee combining user knowledge and active contours

    NASA Astrophysics Data System (ADS)

    Lynch, John A.; Zaim, Souhil; Zhao, Jenny; Stork, Alexander; Peterfy, Charles G.; Genant, Harry K.

    2000-06-01

    A technique for segmentation of articular cartilage from 3D MRI scans of the knee has been developed. It overcomes the limitations of the conventionally used region growing techniques, which are prone to inter- and intra-observer variability, and which can require much manual intervention. We describe a hybrid segmentation method combining expert knowledge with directionally oriented Canny filters, cost functions and cubic splines. After manual initialization, the technique utilized 3 cost functions which aided automated detection of cartilage and its boundaries. Using the sign of the edge strength, and the local direction of the boundary, this technique is more reliable than conventional 'snakes,' and the user had little control over smoothness of boundaries. This means that the automatically detected boundary can conform to the true shape of the real boundary, also allowing reliable detection of subtle local lesions on the normally smooth cartilage surface. Manual corrections, with possible re-optimization were sometimes needed. When compared to the conventionally used region growing techniques, this newly described technique measured local cartilage volume with 3 times better reproducibility, and involved two thirds less human interaction. Combined with the use of 3D image registration, the new technique should also permit unbiased segmentation of followup scans by automated initialization from a baseline segmentation of an earlier scan of the same patient.

  5. Face recognition based on matching of local features on 3D dynamic range sequences

    NASA Astrophysics Data System (ADS)

    Echeagaray-Patrón, B. A.; Kober, Vitaly

    2016-09-01

    3D face recognition has attracted attention in the last decade due to improvement of technology of 3D image acquisition and its wide range of applications such as access control, surveillance, human-computer interaction and biometric identification systems. Most research on 3D face recognition has focused on analysis of 3D still data. In this work, a new method for face recognition using dynamic 3D range sequences is proposed. Experimental results are presented and discussed using 3D sequences in the presence of pose variation. The performance of the proposed method is compared with that of conventional face recognition algorithms based on descriptors.

  6. Silk-based anisotropical 3D biotextiles for bone regeneration.

    PubMed

    Ribeiro, Viviana P; Silva-Correia, Joana; Nascimento, Ana I; da Silva Morais, Alain; Marques, Alexandra P; Ribeiro, Ana S; Silva, Carla J; Bonifácio, Graça; Sousa, Rui A; Oliveira, Joaquim M; Oliveira, Ana L; Reis, Rui L

    2017-04-01

    Bone loss in the craniofacial complex can been treated using several conventional therapeutic strategies that face many obstacles and limitations. In this work, novel three-dimensional (3D) biotextile architectures were developed as a possible strategy for flat bone regeneration applications. As a fully automated processing route, this strategy as potential to be easily industrialized. Silk fibroin (SF) yarns were processed into weft-knitted fabrics spaced by a monofilament of polyethylene terephthalate (PET). A comparative study with a similar 3D structure made entirely of PET was established. Highly porous scaffolds with homogeneous pore distribution were observed using micro-computed tomography analysis. The wet state dynamic mechanical analysis revealed a storage modulus In the frequency range tested, the storage modulus values obtained for SF-PET scaffolds were higher than for the PET scaffolds. Human adipose-derived stem cells (hASCs) cultured on the SF-PET spacer structures showed the typical pattern for ALP activity under osteogenic culture conditions. Osteogenic differentiation of hASCs on SF-PET and PET constructs was also observed by extracellular matrix mineralization and expression of osteogenic-related markers (osteocalcin, osteopontin and collagen type I) after 28 days of osteogenic culture, in comparison to the control basal medium. The quantification of convergent macroscopic blood vessels toward the scaffolds by a chick chorioallantoic membrane assay, showed higher angiogenic response induced by the SF-PET textile scaffolds than PET structures and gelatin sponge controls. Subcutaneous implantation in CD-1 mice revealed tissue ingrowth's accompanied by blood vessels infiltration in both spacer constructs. The structural adaptability of textile structures combined to the structural similarities of the 3D knitted spacer fabrics to craniofacial bone tissue and achieved biological performance, make these scaffolds a possible solution for tissue

  7. Coniferous canopy BRF simulation based on 3-D realistic scene.

    PubMed

    Wang, Xin-Yun; Guo, Zhi-Feng; Qin, Wen-Han; Sun, Guo-Qing

    2011-09-01

    It is difficulties for the computer simulation method to study radiation regime at large-scale. Simplified coniferous model was investigated in the present study. It makes the computer simulation methods such as L-systems and radiosity-graphics combined method (RGM) more powerful in remote sensing of heterogeneous coniferous forests over a large-scale region. L-systems is applied to render 3-D coniferous forest scenarios, and RGM model was used to calculate BRF (bidirectional reflectance factor) in visible and near-infrared regions. Results in this study show that in most cases both agreed well. Meanwhile at a tree and forest level, the results are also good.

  8. OB3D, a new set of 3D objects available for research: a web-based study

    PubMed Central

    Buffat, Stéphane; Chastres, Véronique; Bichot, Alain; Rider, Delphine; Benmussa, Frédéric; Lorenceau, Jean

    2014-01-01

    Studying object recognition is central to fundamental and clinical research on cognitive functions but suffers from the limitations of the available sets that cannot always be modified and adapted to meet the specific goals of each study. We here present a new set of 3D scans of real objects available on-line as ASCII files, OB3D. These files are lists of dots, each defined by a triplet of spatial coordinates and their normal that allow simple and highly versatile transformations and adaptations. We performed a web-based experiment to evaluate the minimal number of dots required for the denomination and categorization of these objects, thus providing a reference threshold. We further analyze several other variables derived from this data set, such as the correlations with object complexity. This new stimulus set, which was found to activate the Lower Occipital Complex (LOC) in another study, may be of interest for studies of cognitive functions in healthy participants and patients with cognitive impairments, including visual perception, language, memory, etc. PMID:25339920

  9. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    PubMed

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T2-FLAIR, 3D-T1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T1-SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T1-SPACE and 3D-T2-FLAIR images yielded significantly more information than MPRAGE images (p < 0.05 for both SPACE and FLAIR images) in detection of meningeal abnormalities. SPACE images best demonstrated abnormalities in dural and sulcal spaces, whereas FLAIR was useful for basal cisterns enhancement. Both SPACE and FLAIR performed equally well in detection of gyral enhancement. In all 10 patients, where both SPACE and T2-FLAIR images failed to demonstrate any abnormality, further analysis was also negative. The 3D-T1-SPACE sequence best demonstrated abnormalities in dural and sulcal spaces, whereas FLAIR was useful for abnormalities in basal cisterns. Both SPACE and FLAIR performed holds good for detection of gyral enhancement. Post-contrast SPACE and FLAIR sequences are superior to the MPRAGE sequence for evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T1-SPACE and 3D-T2-FLAIR images are more useful than 3D-T1-MPRAGE images in evaluation of meningeal abnormalities.

  10. 3D Segmentation with an application of level set-method using MRI volumes for image guided surgery.

    PubMed

    Bosnjak, A; Montilla, G; Villegas, R; Jara, I

    2007-01-01

    This paper proposes an innovation in the application for image guided surgery using a comparative study of three different method of segmentation. This segmentation method is faster than the manual segmentation of images, with the advantage that it allows to use the same patient as anatomical reference, which has more precision than a generic atlas. This new methodology for 3D information extraction is based on a processing chain structured of the following modules: 1) 3D Filtering: the purpose is to preserve the contours of the structures and to smooth the homogeneous areas; several filters were tested and finally an anisotropic diffusion filter was used. 2) 3D Segmentation. This module compares three different methods: Region growing Algorithm, Cubic spline hand assisted, and Level Set Method. It then proposes a Level Set-based on the front propagation method that allows the making of the reconstruction of the internal walls of the anatomical structures of the brain. 3) 3D visualization. The new contribution of this work consists on the visualization of the segmented model and its use in the pre-surgery planning.

  11. Handheld underwater 3D sensor based on fringe projection technique

    NASA Astrophysics Data System (ADS)

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Meng, Lichun; Ramm, Roland; Kühmstedt, Peter; Notni, Gunther

    2015-05-01

    A new, handheld 3D surface scanner was developed especially for underwater use until a diving depth of about 40 meters. Additionally, the sensor is suitable for the outdoor use under bad weather circumstance like splashing water, wind, and bad illumination conditions. The optical components of the sensor are two cameras and one projector. The measurement field is about 250 mm x 200 mm. The depth resolution is about 50 μm and the lateral resolution is approximately 150 μm. The weight of the scanner is about 10 kg. The housing was produced of synthetic powder using a 3D printing technique. The measurement time for one scan is between a third and a half second. The computer for measurement control and data analysis is already integrated into the housing of the scanner. A display on the backside presents the results of each measurement graphically for a real-time evaluation of the user during the recording of the measurement data.

  12. 3D Printing-Based Integrated Water Quality Sensing System.

    PubMed

    Banna, Muinul; Bera, Kaustav; Sochol, Ryan; Lin, Liwei; Najjaran, Homayoun; Sadiq, Rehan; Hoorfar, Mina

    2017-06-08

    The online and accurate monitoring of drinking water supply networks is critically in demand to rapidly detect the accidental or deliberate contamination of drinking water. At present, miniaturized water quality monitoring sensors developed in the laboratories are usually tested under ambient pressure and steady-state flow conditions; however, in Water Distribution Systems (WDS), both the pressure and the flowrate fluctuate. In this paper, an interface is designed and fabricated using additive manufacturing or 3D printing technology-material extrusion (Trade Name: fused deposition modeling, FDM) and material jetting-to provide a conduit for miniaturized sensors for continuous online water quality monitoring. The interface is designed to meet two main criteria: low pressure at the inlet of the sensors and a low flowrate to minimize the water bled (i.e., leakage), despite varying pressure from WDS. To meet the above criteria, a two-dimensional computational fluid dynamics model was used to optimize the geometry of the channel. The 3D printed interface, with the embedded miniaturized pH and conductivity sensors, was then tested at different temperatures and flowrates. The results show that the response of the pH sensor is independent of the flowrate and temperature. As for the conductivity sensor, the flowrate and temperature affect only the readings at a very low conductivity (4 µS/cm) and high flowrates (30 mL/min), and a very high conductivity (460 µS/cm), respectively.

  13. 3D Printing-Based Integrated Water Quality Sensing System

    PubMed Central

    Banna, Muinul; Bera, Kaustav; Sochol, Ryan; Lin, Liwei; Najjaran, Homayoun; Sadiq, Rehan; Hoorfar, Mina

    2017-01-01

    The online and accurate monitoring of drinking water supply networks is critically in demand to rapidly detect the accidental or deliberate contamination of drinking water. At present, miniaturized water quality monitoring sensors developed in the laboratories are usually tested under ambient pressure and steady-state flow conditions; however, in Water Distribution Systems (WDS), both the pressure and the flowrate fluctuate. In this paper, an interface is designed and fabricated using additive manufacturing or 3D printing technology—material extrusion (Trade Name: fused deposition modeling, FDM) and material jetting—to provide a conduit for miniaturized sensors for continuous online water quality monitoring. The interface is designed to meet two main criteria: low pressure at the inlet of the sensors and a low flowrate to minimize the water bled (i.e., leakage), despite varying pressure from WDS. To meet the above criteria, a two-dimensional computational fluid dynamics model was used to optimize the geometry of the channel. The 3D printed interface, with the embedded miniaturized pH and conductivity sensors, was then tested at different temperatures and flowrates. The results show that the response of the pH sensor is independent of the flowrate and temperature. As for the conductivity sensor, the flowrate and temperature affect only the readings at a very low conductivity (4 µS/cm) and high flowrates (30 mL/min), and a very high conductivity (460 µS/cm), respectively. PMID:28594387

  14. [MRI-based radiotherapy planning].

    PubMed

    Largent, A; Nunes, J-C; Lafond, C; Périchon, N; Castelli, J; Rolland, Y; Acosta, O; de Crevoisier, R

    2017-07-06

    MRI-based radiotherapy planning is a topical subject due to the introduction of a new generation of treatment machines combining a linear accelerator and a MRI. One of the issues for introducing MRI in this task is the lack of information to provide tissue density information required for dose calculation. To cope with this issue, two strategies may be distinguished from the literature. Either a synthetic CT scan is generated from the MRI to plan the dose, or a dose is generated from the MRI based on physical underpinnings. Within the first group, three approaches appear: bulk density mapping assign a homogeneous density to different volumes of interest manually defined on a patient MRI; machine learning-based approaches model local relationship between CT and MRI image intensities from multiple data, then applying the model to a new MRI; atlas-based approaches use a co-registered training data set (CT-MRI) which are registered to a new MRI to create a pseudo CT from spatial correspondences in a final fusion step. Within the second group, physics-based approaches aim at computing the dose directly from the hydrogen contained within the tissues, quantified by MRI. Excepting the physics approach, all these methods generate a synthetic CT called "pseudo CT", on which radiotherapy planning will be finally realized. This literature review shows that atlas- and machine learning-based approaches appear more accurate dosimetrically. Bulk density approaches are not appropriate for bone localization. The fastest methods are machine learning and the slowest are atlas-based approaches. The less automatized are bulk density assignation methods. The physical approaches appear very promising methods. Finally, the validation of these methods is crucial for a clinical practice, in particular in the perspective of adaptive radiotherapy delivered by a linear accelerator combined with an MRI scanner. Copyright © 2017. Published by Elsevier SAS.

  15. Fabric defects identification based on on-line 3D measurement

    NASA Astrophysics Data System (ADS)

    Song, Limei; An, Hongwei; Dong, Xiaoxiao; Zhang, Chunbo

    2011-08-01

    This paper using on-line identification of three dimensions to solve some difficult problems of two dimensional defects identification. Different defects have different 3D structural features, thus to identify and classify defects based on 3D testing data. Compared with fabric defects processed by two-dimensional image, 3D identification can more exclude cloth wrinkles and the flying thick silk floss. So the 3D identification is of high accuracy and reliability to identify fabric defects.

  16. Constrained reverse diffusion for thick slice interpolation of 3D volumetric MRI images.

    PubMed

    Neubert, Aleš; Salvado, Olivier; Acosta, Oscar; Bourgeat, Pierrick; Fripp, Jurgen

    2012-03-01

    Due to physical limitations inherent in magnetic resonance imaging scanners, three dimensional volumetric scans are often acquired with anisotropic voxel resolution. We investigate several interpolation approaches to reduce the anisotropy and present a novel approach - constrained reverse diffusion for thick slice interpolation. This technique was compared to common methods: linear and cubic B-Spline interpolation and a technique based on non-rigid registration of neighboring slices. The methods were evaluated on artificial MR phantoms and real MR scans of human brain. The constrained reverse diffusion approach delivered promising results and provides an alternative for thick slice interpolation, especially for higher anisotropy factors.

  17. Coniferous Canopy BRF Simulation Based on 3-D Realistic Scene

    NASA Technical Reports Server (NTRS)

    Wang, Xin-yun; Guo, Zhi-feng; Qin, Wen-han; Sun, Guo-qing

    2011-01-01

    It is difficulties for the computer simulation method to study radiation regime at large-scale. Simplified coniferous model was investigate d in the present study. It makes the computer simulation methods such as L-systems and radiosity-graphics combined method (RGM) more powerf ul in remote sensing of heterogeneous coniferous forests over a large -scale region. L-systems is applied to render 3-D coniferous forest scenarios: and RGM model was used to calculate BRF (bidirectional refle ctance factor) in visible and near-infrared regions. Results in this study show that in most cases both agreed well. Meanwhiie at a tree and forest level. the results are also good.

  18. Development of 3D Slicer based film dosimetry analysis

    NASA Astrophysics Data System (ADS)

    Alexander, K. M.; Robinson, A.; Pinter, C.; Fichtinger, G.; Schreiner, L. J.

    2017-05-01

    Radiochromic film dosimetry has been widely adopted in the clinic as it is a convenient option for dose measurement and verification. Film dosimetry analysis is typically performed using expensive commercial software, or custom made scripts in Matlab. However, common clinical film analysis software is not transparent regarding what corrections/optimizations are running behind the scenes. In this work, an extension to the open-source medical imaging platform 3D Slicer was developed and implemented in our centre for film dosimetry analysis. This extension streamlines importing treatment planning system dose and film imaging data, film calibration, registration, and comparison of 2D dose distributions, enabling greater accessibility to film analysis and higher reliability.

  19. 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    PubMed

    Kasten, Jeffrey A; Vetterli, Thomas; Lazeyras, François; Van De Ville, Dimitri

    2016-01-01

    As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency of rapid prototyping for generating a flexible class of MR-compatible phantom designs. An incarnation of the three-dimensional Shepp-Logan numerical phantom, amended for use in magnetic resonance spectroscopic imaging, was actualized using rapid prototyping. Each of the comprising compartments was filled with a solution containing prepared concentrations of common (1)H brain metabolites. Analytical Fourier expressions for the phantom class were established in order to generate a set of simulated measurements, which were then contrasted with acquired data. Experimental results for both structural and spectroscopic imaging substantiate the suitability of rapid prototyping for MR phantom applications. The analytically simulated measurements show excellent agreement with the measured data, but also highlight the various consequences effectuated when certain aspects of the acquisition model are disregarded or misrepresented. Rapid prototyping offers a novel and versatile framework for MR phantom-based validation studies. Furthermore, the growing accessibility and open-source compatibility may provide an important link between the often disparate numerical and haptic testing. © 2015 Wiley Periodicals, Inc.

  20. 3D fingerprint imaging system based on full-field fringe projection profilometry

    NASA Astrophysics Data System (ADS)

    Huang, Shujun; Zhang, Zonghua; Zhao, Yan; Dai, Jie; Chen, Chao; Xu, Yongjia; Zhang, E.; Xie, Lili

    2014-01-01

    As an unique, unchangeable and easily acquired biometrics, fingerprint has been widely studied in academics and applied in many fields over the years. The traditional fingerprint recognition methods are based on the obtained 2D feature of fingerprint. However, fingerprint is a 3D biological characteristic. The mapping from 3D to 2D loses 1D information and causes nonlinear distortion of the captured fingerprint. Therefore, it is becoming more and more important to obtain 3D fingerprint information for recognition. In this paper, a novel 3D fingerprint imaging system is presented based on fringe projection technique to obtain 3D features and the corresponding color texture information. A series of color sinusoidal fringe patterns with optimum three-fringe numbers are projected onto a finger surface. From another viewpoint, the fringe patterns are deformed by the finger surface and captured by a CCD camera. 3D shape data of the finger can be obtained from the captured fringe pattern images. This paper studies the prototype of the 3D fingerprint imaging system, including principle of 3D fingerprint acquisition, hardware design of the 3D imaging system, 3D calibration of the system, and software development. Some experiments are carried out by acquiring several 3D fingerprint data. The experimental results demonstrate the feasibility of the proposed 3D fingerprint imaging system.

  1. 3-D Cytoarchitectonic parcellation of human orbitofrontal cortex. Correlation with postmortem MRI

    PubMed Central

    Uylings, Harry B.M.; Sanz-Arigita, Ernesto J.; de Vos, Koos; Pool, Chris W.; Evers, Paul; Rajkowska, Grazyna

    2010-01-01

    The orbitofrontal cortex (OFC) is located on the basal surface of the frontal lobe and is distinguished by its unique anatomical and functional features. Clinical and postmortem studies suggest the involvement of the orbitofrontal cortex in psychiatric disorders. However, the exact parcellation of this cortical region is still a matter of debate. Therefore, the goal of this study is to provide a detailed description of the extent of borders of individual orbitofrontal cortical areas using cytoarchitectonic criteria in a large sample of human brains, which could be applied by independent neuroanatomists. To make this microscopic parcellation useful to neuroimaging studies, magnetic resonance images of postmortem brains in the coronal plane were collected prior to the preparation of coronal histological sections from the same brains. A complete series of coronal sections from 6 normal human brains and partial sections from the frontal cortex of 21 normal human brains were stained with general histological and immunohistochemical methods specific for different cell-types, These sections were examined microscopically by two independent neuroanatomists (HBMU and GR) to achieve reproducible delineations. After the borders were determined, the tissue sections were superimposed on corresponding MR images. Based on our cytoarchitectonical criteria, Brodmann's areas 47 and 11 were included in the human orbitofrontal cortex. Area 47 was further subdivided into three medial (located on the medial, anterior and posterior orbital gyri) and two lateral (located on the lateral orbital gyrus) subareas. In addition, we observed an anterior-posterior gradient in the cytoarchitecture of areas 11 and 47. The transverse orbital sulcus corresponds roughly to the transition between the subregions of the anterior and posterior OFC. Finally, the present delineation is contrasted with an overview of the different published nomenclatures for the OFC parcellation. PMID:20538437

  2. The value of 3D-FIESTA MRI in detecting non-iatrogenic cerebrospinal fluid rhinorrhoea: correlations with endoscopic endonasal surgery.

    PubMed

    Xie, Tao; Sun, Wei; Zhang, Xiaobiao; Liu, Tengfei; Ding, Hailing; Hu, Fan; Yu, Yong; Gu, Ye

    2016-12-01

    In this study, we investigated the value of three-dimensional (3D) fast-imaging employing steady-state acquisition (FIESTA) magnetic resonance imaging (MRI) in detecting non-iatrogenic cerebrospinal fluid (CSF) rhinorrhoea and compared it with regular MRI and 3D magnetisation prepared rapid acquisition gradient echo (MPRAGE) MRI sequences, as well as high-resolution computed tomography (HRCT) imaging. We also present the endoscopic experiences of such cases. From June 2011 to Feb 2016, 17 patients with non-iatrogenic cerebrospinal fluid rhinorrhoea were included. Seven patients had spontaneous rhinorrhoea, three patients had invasive tumours, and the remaining patients had traumatic aetiologies. All the patients underwent HRCT, regular MRI sequence imaging, 3D-MPRAGE MRI sequence imaging and 3D-FIESTA MRI sequence imaging for the preoperative evaluations of the leakages. For each patient, the CSF fistula site was confirmed by intraoperative neuronavigation and endoscopic findings. Statistical analyses were performed. All patients underwent endoscopic multilayer repair. The sensitivities of the HRCT, regular MRI (T1 and T2), 3D-MPRAGE and 3D-FIESTA modalities for identifying CSF leakage were 58.8 %, (11.8 % and 29.4 %), 74.7 %, and 88.2 %, respectively. The origins of the leakages included the cribriform plate (18 %), ethmoidal fovea (23 %), lateral recess of the sphenoid (17 %), sellar floor (12 %), ethmoidal roof (12 %), junction of the fovea and cribriform plate (6 %) and the junction of sellar and sphenoidal planum (6 %). Two patients required repair. The first was under local anaesthesia when the nasal packing was removed, and the second underwent repair at the same site a half-year later due to hydrocephalus. Lumbar drainage was performed in all cases. No major complications were encountered. The endoscopic endonasal approach is safe and effective for the treatment of CSF rhinorrhoea. The 3D-FIESTA MR modality is superior to 3D-MPRAGE MR and HRCT

  3. 3-D Adaptive Sparsity Based Image Compression with Applications to Optical Coherence Tomography

    PubMed Central

    Fang, Leyuan; Li, Shutao; Kang, Xudong; Izatt, Joseph A.; Farsiu, Sina

    2015-01-01

    We present a novel general-purpose compression method for tomographic images, termed 3D adaptive sparse representation based compression (3D-ASRC). In this paper, we focus on applications of 3D-ASRC for the compression of ophthalmic 3D optical coherence tomography (OCT) images. The 3D-ASRC algorithm exploits correlations among adjacent OCT images to improve compression performance, yet is sensitive to preserving their differences. Due to the inherent denoising mechanism of the sparsity based 3D-ASRC, the quality of the compressed images are often better than the raw images they are based on. Experiments on clinical-grade retinal OCT images demonstrate the superiority of the proposed 3D-ASRC over other well-known compression methods. PMID:25561591

  4. MIMO based 3D imaging system at 360 GHz

    NASA Astrophysics Data System (ADS)

    Herschel, R.; Nowok, S.; Zimmermann, R.; Lang, S. A.; Pohl, N.

    2016-05-01

    A MIMO radar imaging system at 360 GHz is presented as a part of the comprehensive approach of the European FP7 project TeraSCREEN, using multiple frequency bands for active and passive imaging. The MIMO system consists of 16 transmitter and 16 receiver antennas within one single array. Using a bandwidth of 30 GHz, a range resolution up to 5 mm is obtained. With the 16×16 MIMO system 256 different azimuth bins can be distinguished. Mechanical beam steering is used to measure 130 different elevation angles where the angular resolution is obtained by a focusing elliptical mirror. With this system a high resolution 3D image can be generated with 4 frames per second, each containing 16 million points. The principle of the system is presented starting from the functional structure, covering the hardware design and including the digital image generation. This is supported by simulated data and discussed using experimental results from a preliminary 90 GHz system underlining the feasibility of the approach.

  5. Research of Fast 3D Imaging Based on Multiple Mode

    NASA Astrophysics Data System (ADS)

    Chen, Shibing; Yan, Huimin; Ni, Xuxiang; Zhang, Xiuda; Wang, Yu

    2016-02-01

    Three-dimensional (3D) imaging has received increasingly extensive attention and has been widely used currently. Lots of efforts have been put on three-dimensional imaging method and system study, in order to meet fast and high accurate requirement. In this article, we realize a fast and high quality stereo matching algorithm on field programmable gate array (FPGA) using the combination of time-of-flight (TOF) camera and binocular camera. Images captured from the two cameras own a same spatial resolution, letting us use the depth maps taken by the TOF camera to figure initial disparity. Under the constraint of the depth map as the stereo pairs when comes to stereo matching, expected disparity of each pixel is limited within a narrow search range. In the meanwhile, using field programmable gate array (FPGA, altera cyclone IV series) concurrent computing we can configure multi core image matching system, thus doing stereo matching on embedded system. The simulation results demonstrate that it can speed up the process of stereo matching and increase matching reliability and stability, realize embedded calculation, expand application range.

  6. Contactless operating table control based on 3D image processing.

    PubMed

    Schröder, Stephan; Loftfield, Nina; Langmann, Benjamin; Frank, Klaus; Reithmeier, Eduard

    2014-01-01

    Interaction with mobile consumer devices leads to a higher acceptance and affinity of persons to natural user interfaces and perceptional interaction possibilities. New interaction modalities become accessible and are capable to improve human machine interaction even in complex and high risk environments, like the operation room. Here, manifold medical disciplines cause a great variety of procedures and thus staff and equipment. One universal challenge is to meet the sterility requirements, for which common contact-afflicted remote interfaces always pose a potential risk causing a hazard for the process. The proposed operating table control system overcomes this process risk and thus improves the system usability significantly. The 3D sensor system, the Microsoft Kinect, captures the motion of the user, allowing a touchless manipulation of an operating table. Three gestures enable the user to select, activate and manipulate all segments of the motorised system in a safe and intuitive way. The gesture dynamics are synchronised with the table movement. In a usability study, 15 participants evaluated the system with a system usability score by Broke of 79. This states a high potential for implementation and acceptance in interventional environments. In the near future, even processes with higher risks could be controlled with the proposed interface, while interfaces become safer and more direct.

  7. New 3-D microarray platform based on macroporous polymer monoliths.

    PubMed

    Rober, M; Walter, J; Vlakh, E; Stahl, F; Kasper, C; Tennikova, T

    2009-06-30

    Polymer macroporous monoliths are widely used as efficient sorbents in different, mostly dynamic, interphase processes. In this paper, monolithic materials strongly bound to the inert glass surface are suggested as operative matrices at the development of three-dimensional (3-D) microarrays. For this purpose, several rigid macroporous copolymers differed by reactivity and hydrophobic-hydrophilic properties were synthesized and tested: (1) glycidyl methacrylate-co-ethylene dimethacrylate (poly(GMA-co-EDMA)), (2) glycidyl methacrylate-co-glycerol dimethacrylate (poly(GMA-co-GDMA)), (3) N-hydroxyphthalimide ester of acrylic acid-co-glycidyl methacrylate-co-ethylene dimethacrylate (poly(HPIEAA-co-GMA-co-EDMA)), (4) 2-cyanoethyl methacrylate-co-ethylene dimethacrylate (poly(CEMA-co-EDMA)), and (5) 2-cyanoethyl methacrylate-co-2-hydroxyethyl methacrylate-co-ethylene dimethacrylate (poly(CEMA-co-HEMA-co-EDMA)). The constructed devices were used as platforms for protein microarrays construction and model mouse IgG-goat anti-mouse IgG affinity pair was used to demonstrate the potential of developed test-systems, as well as to optimize microanalytical conditions. The offered microarray platforms were applied to detect the bone tissue marker osteopontin directly in cell culture medium.

  8. 3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson-disc sampling.

    PubMed

    Levine, Evan; Daniel, Bruce; Vasanawala, Shreyas; Hargreaves, Brian; Saranathan, Manojkumar

    2017-05-01

    To enable robust, high spatio-temporal-resolution three-dimensional Cartesian MRI using a scheme incorporating a novel variable density random k-space sampling trajectory allowing flexible and retrospective selection of the temporal footprint with compressed sensing (CS). A complementary Poisson-disc k-space sampling trajectory was designed to allow view sharing and varying combinations of reduced view sharing with CS from the same prospective acquisition. These schemes were used for two-point Dixon-based dynamic contrast-enhanced MRI (DCE-MRI) of the breast and abdomen. Results were validated in vivo with a novel approach using variable-flip-angle data, which was retrospectively accelerated using the same methods but offered a ground truth. In breast DCE-MRI, the temporal footprint could be reduced 2.3-fold retrospectively without introducing noticeable artifacts, improving depiction of rapidly enhancing lesions. Further, experiments with variable-flip-angle data showed that reducing view sharing improved accuracy in reconstruction and T1 mapping. In abdominal MRI, 2.3-fold and 3.6-fold reductions in temporal footprint allowed reduced motion artifacts. The complementary-Poisson-disc k-space sampling trajectory allowed a retrospective spatiotemporal resolution tradeoff using CS and view sharing, imparting robustness to motion and contrast enhancement. The technique was also validated using a novel approach of fully acquired variable-flip-angle acquisition. Magn Reson Med 77:1774-1785, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model.

    PubMed

    Rusu, Mirabela; Golden, Thea; Wang, Haibo; Gow, Andrew; Madabhushi, Anant

    2015-08-01

    Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors' framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. The authors' image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology-MRI fusion, in the context of an initial use case involving characterization of chronic inflammation in a mouse model. The authors

  10. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    PubMed Central

    Rusu, Mirabela; Golden, Thea; Wang, Haibo; Gow, Andrew; Madabhushi, Anant

    2015-01-01

    Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic

  11. Framework for 3D histologic reconstruction and fusion with in vivo MRI: Preliminary results of characterizing pulmonary inflammation in a mouse model

    SciTech Connect

    Rusu, Mirabela Wang, Haibo; Madabhushi, Anant; Golden, Thea; Gow, Andrew

    2015-08-15

    Purpose: Pulmonary inflammation is associated with a variety of diseases. Assessing pulmonary inflammation on in vivo imaging may facilitate the early detection and treatment of lung diseases. Although routinely used in thoracic imaging, computed tomography has thus far not been compellingly shown to characterize inflammation in vivo. Alternatively, magnetic resonance imaging (MRI) is a nonionizing radiation technique to better visualize and characterize pulmonary tissue. Prior to routine adoption of MRI for early characterization of inflammation in humans, a rigorous and quantitative characterization of the utility of MRI to identify inflammation is required. Such characterization may be achieved by considering ex vivo histology as the ground truth, since it enables the definitive spatial assessment of inflammation. In this study, the authors introduce a novel framework to integrate 2D histology, ex vivo and in vivo imaging to enable the mapping of the extent of disease from ex vivo histology onto in vivo imaging, with the goal of facilitating computerized feature analysis and interrogation of disease appearance on in vivo imaging. The authors’ framework was evaluated in a preclinical preliminary study aimed to identify computer extracted features on in vivo MRI associated with chronic pulmonary inflammation. Methods: The authors’ image analytics framework first involves reconstructing the histologic volume in 3D from individual histology slices. Second, the authors map the disease ground truth onto in vivo MRI via coregistration with 3D histology using the ex vivo lung MRI as a conduit. Finally, computerized feature analysis of the disease extent is performed to identify candidate in vivo imaging signatures of disease presence and extent. Results: The authors evaluated the framework by assessing the quality of the 3D histology reconstruction and the histology—MRI fusion, in the context of an initial use case involving characterization of chronic

  12. Recent improvements in SPE3D: a VR-based surgery planning environment

    NASA Astrophysics Data System (ADS)

    Witkowski, Marcin; Sitnik, Robert; Verdonschot, Nico

    2014-02-01

    SPE3D is a surgery planning environment developed within TLEMsafe project [1] (funded by the European Commission FP7). It enables the operator to plan a surgical procedure on the customized musculoskeletal (MS) model of the patient's lower limbs, send the modified model to the biomechanical analysis module, and export the scenario's parameters to the surgical navigation system. The personalized patient-specific three-dimensional (3-D) MS model is registered with 3-D MRI dataset of lower limbs and the two modalities may be visualized simultaneously. Apart from main planes, any arbitrary MRI cross-section can be rendered on the 3-D MS model in real time. The interface provides tools for: bone cutting, manipulating and removal, repositioning muscle insertion points, modifying muscle force, removing muscles and placing implants stored in the implant library. SPE3D supports stereoscopic viewing as well as natural inspection/manipulation with use of haptic devices. Alternatively, it may be controlled with use of a standard computer keyboard, mouse and 2D display or a touch screen (e.g. in an operating room). The interface may be utilized in two main fields. Experienced surgeons may use it to simulate their operative plans and prepare input data for a surgical navigation system while student or novice surgeons can use it for training.

  13. Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom

    SciTech Connect

    Walker, Amy Metcalfe, Peter; Liney, Gary; Holloway, Lois; Dowling, Jason; Rivest-Henault, David

    2015-04-15

    Purpose: Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. Methods: A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. Results: MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%–70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through

  14. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom.

    PubMed

    Walker, Amy; Liney, Gary; Holloway, Lois; Dowling, Jason; Rivest-Henault, David; Metcalfe, Peter

    2015-04-01

    Accurate geometry is required for radiotherapy treatment planning (RTP). When considering the use of magnetic resonance imaging (MRI) for RTP, geometric distortions observed in the acquired images should be considered. While scanner technology and vendor supplied correction algorithms provide some correction, large distortions are still present in images, even when considering considerably smaller scan lengths than those typically acquired with CT in conventional RTP. This study investigates MRI acquisition with a moving table compared with static scans for potential geometric benefits for RTP. A full field of view (FOV) phantom (diameter 500 mm; length 513 mm) was developed for measuring geometric distortions in MR images over volumes pertinent to RTP. The phantom consisted of layers of refined plastic within which vitamin E capsules were inserted. The phantom was scanned on CT to provide the geometric gold standard and on MRI, with differences in capsule location determining the distortion. MRI images were acquired with two techniques. For the first method, standard static table acquisitions were considered. Both 2D and 3D acquisition techniques were investigated. With the second technique, images were acquired with a moving table. The same sequence was acquired with a static table and then with table speeds of 1.1 mm/s and 2 mm/s. All of the MR images acquired were registered to the CT dataset using a deformable B-spline registration with the resulting deformation fields providing the distortion information for each acquisition. MR images acquired with the moving table enabled imaging of the whole phantom length while images acquired with a static table were only able to image 50%-70% of the phantom length of 513 mm. Maximum distortion values were reduced across a larger volume when imaging with a moving table. Increased table speed resulted in a larger contribution of distortion from gradient nonlinearities in the through-plane direction and an increased

  15. 3D 3He diffusion MRI as a local in vivo morphometric tool to evaluate emphysematous rat lungs

    PubMed Central

    Jacob, R. E.; Minard, K. R.; Laicher, G.; Timchalk, C.

    2008-01-01

    In this work, we investigate 3He magnetic resonance imaging as a noninvasive morphometric tool to assess emphysematous disease state on a local level. Emphysema was induced intratracheally in rats with 25 U/100 g body wt of porcine pancreatic elastase dissolved in 200 μl saline. Rats were then paired with saline-dosed controls. Nine three-dimensional (3D) 3He diffusion-weighted images were acquired at 1, 2, or 3 wk postdose, after which the lungs were harvested and prepared for histological analysis. Recently introduced indexes sensitive to the heterogeneity of the air space size distribution were calculated. These indexes, D1 and D2, were derived from the moments of the mean equivalent airway diameters. Averaged over the entire lung, it is shown that the average 3He diffusivity (Dave) correlates well with histology (R = 0.85, P < 0.0001). By matching small (0.046 cm2) regions in 3He images with corresponding regions in histological slices, Dave correlates significantly with both D1 and D2 (R = 0.88 and R = 0.90, respectively, with P < 0.0001). It is concluded that 3He MRI is a viable noninvasive morphometric tool for localized in vivo emphysema assessment. PMID:18719237

  16. 3D-FIESTA MRI at 3 T demonstrating branches of the intraparotid facial nerve, parotid ducts and relation with benign parotid tumours.

    PubMed

    Li, Chuanting; Li, Yan; Zhang, Dongsheng; Yang, Zhenzhen; Wu, Lebin

    2012-11-01

    To investigate the usefulness of three-dimensional (3D) fast imaging employing steady state precession (FIESTA) magnetic resonance imaging (MRI) at 3 T in evaluating the intraparotid components of the facial nerve and parotid ducts, and to compare the MRI images with surgical findings. Thirty-one cases of benign parotid tumours were studied with conventional and 3D FIESTA MRI sequences at 3T using a head coil. The most clinically useful 3D FIESTA images were acquired at parameters of 4.9 ms repetition time (TR); 1.5 effective echo time (TEeff); a flip of 55°, a field of view of 18 to 20 cm, a matrix of 512 × 320, an axial plane, no gaps, and a section thickness of 1 mm. Post-processed multiplanar images were obtained with an Advantage Windows (AW sdc 4.3) workstation. Parotid ducts, facial nerves, and tumours were identified on these images. The relationship of the tumours to the facial nerves and parotid ducts was confirmed at surgery. The facial nerves appeared as linear structures of low intensity. The main trunk of the facial nerve was identified bilaterally in 93.5% of the 3D-FIESTA sequence images. Parotid ducts appeared as structures of high intensity on multiplanar 3D-FIESTA images (100%). The relationships of the tumours with the cervicofacial and temporofacial divisions of the facial nerve were correctly diagnosed in 26 of 31 cases (83.9%) using 3D-FIESTA sequence images. 3D-FIESTA MRI at 3 T depicted the main trunk, cervicofacial and temporofacial divisions of the facial nerve, and the main parotid duct. It is useful for preoperative evaluation of parotid gland tumours. Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

    SciTech Connect

    Deng, Z; Pang, J; Yang, W; Yue, Y; Tuli, R; Fraass, B; Li, D; Fan, Z

    2014-06-15

    Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins

  18. 3D-2D ultrasound feature-based registration for navigated prostate biopsy: a feasibility study.

    PubMed

    Selmi, Sonia Y; Promayon, Emmanuel; Troccaz, Jocelyne

    2016-08-01

    The aim of this paper is to describe a 3D-2D ultrasound feature-based registration method for navigated prostate biopsy and its first results obtained on patient data. A system combining a low-cost tracking system and a 3D-2D registration algorithm was designed. The proposed 3D-2D registration method combines geometric and image-based distances. After extracting features from ultrasound images, 3D and 2D features within a defined distance are matched using an intensity-based function. The results are encouraging and show acceptable errors with simulated transforms applied on ultrasound volumes from real patients.

  19. 3D reconstruction based on multiple views for close-range objects

    NASA Astrophysics Data System (ADS)

    Ji, Zheng; Zhang, Jianqing

    2007-06-01

    It is difficult for traditional photogrammetry techniques to reconstruct 3D model of close-range objects. To overcome the restriction and realize complex objects' 3D reconstruction, we present a realistic approach on the basis of multi-baseline stereo vision. This incorporates the image matching based on short-baseline-multi-views, and 3D measurement based on multi-ray intersection, and the 3D reconstruction of the object's based on TIN or parametric geometric model. Different complex object are reconstructed by this way. The results demonstrate the feasibility and effectivity of the method.

  20. A primitive-based 3D object recognition system

    NASA Technical Reports Server (NTRS)

    Dhawan, Atam P.

    1988-01-01

    An intermediate-level knowledge-based system for decomposing segmented data into three-dimensional primitives was developed to create an approximate three-dimensional description of the real world scene from a single two-dimensional perspective view. A knowledge-based approach was also developed for high-level primitive-based matching of three-dimensional objects. Both the intermediate-level decomposition and the high-level interpretation are based on the structural and relational matching; moreover, they are implemented in a frame-based environment.

  1. Disparity pattern-based autostereoscopic 3D metrology system for in situ measurement of microstructured surfaces.

    PubMed

    Li, Da; Cheung, Chi Fai; Ren, MingJun; Whitehouse, David; Zhao, Xing

    2015-11-15

    This paper presents a disparity pattern-based autostereoscopic (DPA) 3D metrology system that makes use of a microlens array to capture raw 3D information of the measured surface in a single snapshot through a CCD camera. Hence, a 3D digital model of the target surface with the measuring data is generated through a system-associated direct extraction of disparity information (DEDI) method. The DEDI method is highly efficient for performing the direct 3D mapping of the target surface based on tomography-like operation upon every depth plane with the defocused information excluded. Precise measurement results are provided through an error-elimination process based on statistical analysis. Experimental results show that the proposed DPA 3D metrology system is capable of measuring 3D microstructured surfaces with submicrometer measuring repeatability for high precision and in situ measurement of microstructured surfaces.

  2. Predicting Alzheimer's disease by classifying 3D-Brain MRI images using SVM and other well-defined classifiers

    NASA Astrophysics Data System (ADS)

    Matoug, S.; Abdel-Dayem, A.; Passi, K.; Gross, W.; Alqarni, M.

    2012-02-01

    Alzheimer's disease (AD) is the most common form of dementia affecting seniors age 65 and over. When AD is suspected, the diagnosis is usually confirmed with behavioural assessments and cognitive tests, often followed by a brain scan. Advanced medical imaging and pattern recognition techniques are good tools to create a learning database in the first step and to predict the class label of incoming data in order to assess the development of the disease, i.e., the conversion from prodromal stages (mild cognitive impairment) to Alzheimer's disease, which is the most critical brain disease for the senior population. Advanced medical imaging such as the volumetric MRI can detect changes in the size of brain regions due to the loss of the brain tissues. Measuring regions that atrophy during the progress of Alzheimer's disease can help neurologists in detecting and staging the disease. In the present investigation, we present a pseudo-automatic scheme that reads volumetric MRI, extracts the middle slices of the brain region, performs segmentation in order to detect the region of brain's ventricle, generates a feature vector that characterizes this region, creates an SQL database that contains the generated data, and finally classifies the images based on the extracted features. For our results, we have used the MRI data sets from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database.

  3. Rapid 3D dynamic arterial spin labeling with a sparse model-based image reconstruction.

    PubMed

    Zhao, Li; Fielden, Samuel W; Feng, Xue; Wintermark, Max; Mugler, John P; Meyer, Craig H

    2015-11-01

    Dynamic arterial spin labeling (ASL) MRI measures the perfusion bolus at multiple observation times and yields accurate estimates of cerebral blood flow in the presence of variations in arterial transit time. ASL has intrinsically low signal-to-noise ratio (SNR) and is sensitive to motion, so that extensive signal averaging is typically required, leading to long scan times for dynamic ASL. The goal of this study was to develop an accelerated dynamic ASL method with improved SNR and robustness to motion using a model-based image reconstruction that exploits the inherent sparsity of dynamic ASL data. The first component of this method is a single-shot 3D turbo spin echo spiral pulse sequence accelerated using a combination of parallel imaging and compressed sensing. This pulse sequence was then incorporated into a dynamic pseudo continuous ASL acquisition acquired at multiple observation times, and the resulting images were jointly reconstructed enforcing a model of potential perfusion time courses. Performance of the technique was verified using a numerical phantom and it was validated on normal volunteers on a 3-Tesla scanner. In simulation, a spatial sparsity constraint improved SNR and reduced estimation errors. Combined with a model-based sparsity constraint, the proposed method further improved SNR, reduced estimation error and suppressed motion artifacts. Experimentally, the proposed method resulted in significant improvements, with scan times as short as 20s per time point. These results suggest that the model-based image reconstruction enables rapid dynamic ASL with improved accuracy and robustness.

  4. Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

    PubMed

    Hao, Sun; Fessler, Jeffrey A; Noll, Douglas C; Nielsen, Jon-Fredrik

    2016-02-01

    We propose a new method for the joint design of k-space trajectory and RF pulse in 3D small-tip tailored excitation. Designing time-varying RF and gradient waveforms for a desired 3D target excitation pattern in MRI poses a non-linear, non-convex, constrained optimization problem with relatively large problem size that is difficult to solve directly. Existing joint pulse design approaches are therefore typically restricted to predefined trajectory types such as EPI or stack-of-spirals that intrinsically satisfy the gradient maximum and slew rate constraints and reduce the problem size (dimensionality) dramatically, but lead to suboptimal excitation accuracy for a given pulse duration. Here we use a 2nd-order B-spline basis that can be fitted to an arbitrary k-space trajectory, and allows the gradient constraints to be implemented efficiently. We show that this allows the joint optimization problem to be solved with quite general k-space trajectories. Starting from an arbitrary initial trajectory, we first approximate the trajectory using B-spline basis, and then optimize the corresponding coefficients. We evaluate our method in simulation using four different k-space initializations: stack-of-spirals, SPINS, KT-points, and a new method based on KT-points. In all cases, our approach leads to substantial improvement in excitation accuracy for a given pulse duration. We also validated our method for inner-volume excitation using phantom experiments. The computation is fast enough for online applications.

  5. Optimizing visual comfort for stereoscopic 3D display based on color-plus-depth signals.

    PubMed

    Shao, Feng; Jiang, Qiuping; Fu, Randi; Yu, Mei; Jiang, Gangyi

    2016-05-30

    Visual comfort is a long-facing problem in stereoscopic 3D (S3D) display. In this paper, targeting to produce S3D content based on color-plus-depth signals, a general framework for depth mapping to optimize visual comfort for S3D display is proposed. The main motivation of this work is to remap the depth range of color-plus-depth signals to a new depth range that is suitable to comfortable S3D display. Towards this end, we first remap the depth range globally based on the adjusted zero disparity plane, and then present a two-stage global and local depth optimization solution to solve the visual comfort problem. The remapped depth map is used to generate the S3D output. We demonstrate the power of our approach on perceptually uncomfortable and comfortable stereoscopic images.

  6. a Quadtree Organization Construction and Scheduling Method for Urban 3d Model Based on Weight

    NASA Astrophysics Data System (ADS)

    Yao, C.; Peng, G.; Song, Y.; Duan, M.

    2017-09-01

    The increasement of Urban 3D model precision and data quantity puts forward higher requirements for real-time rendering of digital city model. Improving the organization, management and scheduling of 3D model data in 3D digital city can improve the rendering effect and efficiency. This paper takes the complexity of urban models into account, proposes a Quadtree construction and scheduling rendering method for Urban 3D model based on weight. Divide Urban 3D model into different rendering weights according to certain rules, perform Quadtree construction and schedule rendering according to different rendering weights. Also proposed an algorithm for extracting bounding box extraction based on model drawing primitives to generate LOD model automatically. Using the algorithm proposed in this paper, developed a 3D urban planning&management software, the practice has showed the algorithm is efficient and feasible, the render frame rate of big scene and small scene are both stable at around 25 frames.

  7. Robust extrapolation scheme for fast estimation of 3D ising field partition functions: application to within-subject fMRI data analysis.

    PubMed

    Risser, Laurent; Vincent, Thomas; Ciuciu, Philippe; Idier, Jérôme

    2009-01-01

    In this paper, we present a fast numerical scheme to estimate Partition Functions (PF) of 3D Ising fields. Our strategy is applied to the context of the joint detection-estimation of brain activity from functional Magnetic Resonance Imaging (fMRI) data, where the goal is to automatically recover activated regions and estimate region-dependent hemodynamic filters. For any region, a specific binary Markov random field may embody spatial correlation over the hidden states of the voxels by modeling whether they are activated or not. To make this spatial regularization fully adaptive, our approach is first based upon a classical path-sampling method to approximate a small subset of reference PFs corresponding to prespecified regions. Then, the proposed extrapolation method allows us to approximate the PFs associated with the Ising fields defined over the remaining brain regions. In comparison with preexisting approaches, our method is robust to topological inhomogeneities in the definition of the reference regions. As a result, it strongly alleviates the computational burden and makes spatially adaptive regularization of whole brain fMRI datasets feasible.

  8. CT and MRI Assessment and Characterization Using Segmentation and 3D Modeling Techniques: Applications to Muscle, Bone and Brain.

    PubMed

    Gargiulo, Paolo; Helgason, Thordur; Ramon, Ceon; Jr, Halldór Jónsson; Carraro, Ugo

    2014-03-31

    This paper reviews the novel use of CT and MRI data and image processing tools to segment and reconstruct tissue images in 3D to determine characteristics of muscle, bone and brain. This to study and simulate the structural changes occurring in healthy and pathological conditions as well as in response to clinical treatments. Here we report the application of this methodology to evaluate and quantify: 1. progression of atrophy in human muscle subsequent to permanent lower motor neuron (LMN) denervation, 2. muscle recovery as induced by functional electrical stimulation (FES), 3. bone quality in patients undergoing total hip replacement and 4. to model the electrical activity of the brain. Study 1: CT data and segmentation techniques were used to quantify changes in muscle density and composition by associating the Hounsfield unit values of muscle, adipose and fibrous connective tissue with different colors. This method was employed to monitor patients who have permanent muscle LMN denervation in the lower extremities under two different conditions: permanent LMN denervated not electrically stimulated and stimulated. Study 2: CT data and segmentation techniques were employed, however, in this work we assessed bone and muscle conditions in the pre-operative CT scans of patients scheduled to undergo total hip replacement. In this work, the overall anatomical structure, the bone mineral density (BMD) and compactness of quadriceps muscles and proximal femoral was computed to provide a more complete view for surgeons when deciding which implant technology to use. Further, a Finite element analysis provided a map of the strains around the proximal femur socket when solicited by typical stresses caused by an implant press fitting. Study 3 describes a method to model the electrical behavior of human brain using segmented MR images. The aim of the work is to use these models to predict the electrical activity of the human brain under normal and pathological conditions by

  9. CT and MRI Assessment and Characterization Using Segmentation and 3D Modeling Techniques: Applications to Muscle, Bone and Brain

    PubMed Central

    Helgason, Thordur; Ramon, Ceon; jr, Halldór Jónsson; Carraro, Ugo

    2014-01-01

    This paper reviews the novel use of CT and MRI data and image processing tools to segment and reconstruct tissue images in 3D to determine characteristics of muscle, bone and brain. This to study and simulate the structural changes occurring in healthy and pathological conditions as well as in response to clinical treatments. Here we report the application of this methodology to evaluate and quantify: 1. progression of atrophy in human muscle subsequent to permanent lower motor neuron (LMN) denervation, 2. muscle recovery as induced by functional electrical stimulation (FES), 3. bone quality in patients undergoing total hip replacement and 4. to model the electrical activity of the brain. Study 1: CT data and segmentation techniques were used to quantify changes in muscle density and composition by associating the Hounsfield unit values of muscle, adipose and fibrous connective tissue with different colors. This method was employed to monitor patients who have permanent muscle LMN denervation in the lower extremities under two different conditions: permanent LMN denervated not electrically stimulated and stimulated. Study 2: CT data and segmentation techniques were employed, however, in this work we assessed bone and muscle conditions in the pre-operative CT scans of patients scheduled to undergo total hip replacement. In this work, the overall anatomical structure, the bone mineral density (BMD) and compactness of quadriceps muscles and proximal femoral was computed to provide a more complete view for surgeons when deciding which implant technology to use. Further, a Finite element analysis provided a map of the strains around the proximal femur socket when solicited by typical stresses caused by an implant press fitting. Study 3 describes a method to model the electrical behavior of human brain using segmented MR images. The aim of the work is to use these models to predict the electrical activity of the human brain under normal and pathological conditions by

  10. Learning in 3-D Multiuser Virtual Environments: Exploring the Use of Unique 3-D Attributes for Online Problem-Based Learning

    ERIC Educational Resources Information Center

    Omale, Nicholas; Hung, Wei-Chen; Luetkehans, Lara; Cooke-Plagwitz, Jessamine

    2009-01-01

    The purpose of this article is to present the results of a study conducted to investigate how the attributes of 3-D technology such as avatars, 3-D space, and comic style bubble dialogue boxes affect participants' social, cognitive, and teaching presences in a blended problem-based learning environment. The community of inquiry model was adopted…

  11. Conformal cubical 3D transformation-based metamaterial invisibility cloak.

    PubMed

    Savić, Slobodan V; Notaroš, Branislav M; Ilić, Milan M

    2013-01-01

    A conformal cubical transformation-based metamaterial invisibility cloak is presented and verified, in the near and the far field, by a rigorous full-wave numerical technique based on a higher-order, large-domain finite element method, employing large anisotropic, continuously inhomogeneous generalized hexahedral finite elements, with no need for discretization of the permittivity and permeability profiles of the cloak. The analysis requires about 30 times fewer unknowns than with commercial software. To our knowledge, this is the first conformal cubical cloak and the first full-wave computational characterization of such a structure with sharp edges. The presented methodology can also be used in development of conformal, transformation-based perfectly matched layers.

  12. Geofencing-Based Localization for 3d Data Acquisition Navigation

    NASA Astrophysics Data System (ADS)

    Nakagawa, M.; Kamio, T.; Yasojima, H.; Kobayashi, T.

    2016-06-01

    Users require navigation for many location-based applications using moving sensors, such as autonomous robot control, mapping route navigation and mobile infrastructure inspection. In indoor environments, indoor positioning systems using GNSSs can provide seamless indoor-outdoor positioning and navigation services. However, instabilities in sensor position data acquisition remain, because the indoor environment is more complex than the outdoor environment. On the other hand, simultaneous localization and mapping processing is better than indoor positioning for measurement accuracy and sensor cost. However, it is not easy to estimate position data from a single viewpoint directly. Based on these technical issues, we focus on geofencing techniques to improve position data acquisition. In this research, we propose a methodology to estimate more stable position or location data using unstable position data based on geofencing in indoor environments. We verify our methodology through experiments in indoor environments.

  13. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent.

    PubMed

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Bock, Michael; Kauczor, Hans-Ulrich

    2004-07-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 degrees; voxel size: 1.3 x 2.5 x 4.0 mm3; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 degrees; voxel size: 0.8 x 1.0 x 1.6 mm3) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n = 2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21 +/- 8 vs. 13 +/- 3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer.

  14. CT Image Sequence Analysis for Object Recognition - A Rule-Based 3-D Computer Vision System

    Treesearch

    Dongping Zhu; Richard W. Conners; Daniel L. Schmoldt; Philip A. Araman

    1991-01-01

    Research is now underway to create a vision system for hardwood log inspection using a knowledge-based approach. In this paper, we present a rule-based, 3-D vision system for locating and identifying wood defects using topological, geometric, and statistical attributes. A number of different features can be derived from the 3-D input scenes. These features and evidence...

  15. [3-D endocardial surface modelling based on the convex hull algorithm].

    PubMed

    Lu, Ying; Xi, Ri-hui; Shen, Hai-dong; Ye, You-li; Zhang, Yong

    2006-11-01

    In this paper, a method based on the convex hull algorithm is presented for extracting modelling data from the locations of catheter electrodes within a cardiac chamber, so as to create a 3-D model of the heart chamber during diastole and to obtain a good result in the 3-D reconstruction of the chamber based on VTK.

  16. A Tetraperylene Diimides Based 3D Nonfullerene Acceptor for Efficient Organic Photovoltaics.

    PubMed

    Liu, Shi-Yong; Wu, Chen-Hao; Li, Chang-Zhi; Liu, Sheng-Qiang; Wei, Kung-Hwa; Chen, Hong-Zheng; Jen, Alex K-Y

    2015-04-01

    A nonfullerene acceptor based on a 3D tetraperylene diimide is developed for bulk heterojunction organic photovoltaics. The disruption of perylene diimide planarity with a 3D framework suppresses the self-aggregation of perylene diimide and inhibits excimer formation. From planar monoperylene diimide to 3D tetraperylene diimide, a significant improvement of power conversion efficiency from 0.63% to 3.54% can be achieved.

  17. Quantitative 3D Ultrashort Time-to-Echo (UTE) MRI and Micro-CT (μCT) Evaluation of the Temporomandibular Joint (TMJ) Condylar Morphology

    PubMed Central

    Geiger, Daniel; Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B.

    2014-01-01

    Objective Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. Purpose of this study was to determine accuracy of novel 3D-UTE MRI versus micro-CT (μCT) for quantitative evaluation of mandibular condyle morphology. Material & Methods Nine TMJ condyle specimens were harvested from cadavers (2M, 3F; Age 85 ± 10 yrs., mean±SD). 3D-UTE MRI (TR=50ms, TE=0.05 ms, 104 μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18 μm isotropic-voxel) was performed. MR datasets were spatially-registered with μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature and segmented volume of the bone were determined using intraclass correlation correlation (ICC) analyses. Results Between MRI and μCT, the average deviation of surface coordinates was 0.19±0.15 mm, slightly higher than spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7±6.5% and 6.6±6.2%, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature and segmented volumes were respectively 0.892, 0.893 and 0.972. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999 and 0.997 respectively. Fibrocartilage thickness was 0.55±0.11 mm, as previously described in literature for grossly normal TMJ samples. Conclusion 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  18. Future of photorefractive based holographic 3D display

    NASA Astrophysics Data System (ADS)

    Blanche, P.-A.; Bablumian, A.; Voorakaranam, R.; Christenson, C.; Lemieux, D.; Thomas, J.; Norwood, R. A.; Yamamoto, M.; Peyghambarian, N.

    2010-02-01

    The very first demonstration of our refreshable holographic display based on photorefractive polymer was published in Nature early 20081. Based on the unique properties of a new organic photorefractive material and the holographic stereography technique, this display addressed a gap between large static holograms printed in permanent media (photopolymers) and small real time holographic systems like the MIT holovideo. Applications range from medical imaging to refreshable maps and advertisement. Here we are presenting several technical solutions for improving the performance parameters of the initial display from an optical point of view. Full color holograms can be generated thanks to angular multiplexing, the recording time can be reduced from minutes to seconds with a pulsed laser, and full parallax hologram can be recorded in a reasonable time thanks to parallel writing. We also discuss the future of such a display and the possibility of video rate.

  19. Building a 3D scanner system based on monocular vision.

    PubMed

    Zhang, Zhiyi; Yuan, Lin

    2012-04-10

    This paper proposes a three-dimensional scanner system, which is built by using an ingenious geometric construction method based on monocular vision. The system is simple, low cost, and easy to use, and the measurement results are very precise. To build it, one web camera, one handheld linear laser, and one background calibration board are required. The experimental results show that the system is robust and effective, and the scanning precision can be satisfied for normal users.

  20. Novel methodology for 3D reconstruction of carotid arteries and plaque characterization based upon magnetic resonance imaging carotid angiography data.

    PubMed

    Sakellarios, Antonis I; Stefanou, Kostas; Siogkas, Panagiotis; Tsakanikas, Vasilis D; Bourantas, Christos V; Athanasiou, Lambros; Exarchos, Themis P; Fotiou, Evangelos; Naka, Katerina K; Papafaklis, Michail I; Patterson, Andrew J; Young, Victoria E L; Gillard, Jonathan H; Michalis, Lampros K; Fotiadis, Dimitrios I

    2012-10-01

    In this study, we present a novel methodology that allows reliable segmentation of the magnetic resonance images (MRIs) for accurate fully automated three-dimensional (3D) reconstruction of the carotid arteries and semiautomated characterization of plaque type. Our approach uses active contours to detect the luminal borders in the time-of-flight images and the outer vessel wall borders in the T(1)-weighted images. The methodology incorporates the connecting components theory for the automated identification of the bifurcation region and a knowledge-based algorithm for the accurate characterization of the plaque components. The proposed segmentation method was validated in randomly selected MRI frames analyzed offline by two expert observers. The interobserver variability of the method for the lumen and outer vessel wall was -1.60%±6.70% and 0.56%±6.28%, respectively, while the Williams Index for all metrics was close to unity. The methodology implemented to identify the composition of the plaque was also validated in 591 images acquired from 24 patients. The obtained Cohen's k was 0.68 (0.60-0.76) for lipid plaques, while the time needed to process an MRI sequence for 3D reconstruction was only 30 s. The obtained results indicate that the proposed methodology allows reliable and automated detection of the luminal and vessel wall borders and fast and accurate characterization of plaque type in carotid MRI sequences. These features render the currently presented methodology a useful tool in the clinical and research arena.

  1. A cross-platform solution for light field based 3D telemedicine.

    PubMed

    Wang, Gengkun; Xiang, Wei; Pickering, Mark

    2016-03-01

    Current telehealth services are dominated by conventional 2D video conferencing systems, which are limited in their capabilities in providing a satisfactory communication experience due to the lack of realism. The "immersiveness" provided by 3D technologies has the potential to promote telehealth services to a wider range of applications. However, conventional stereoscopic 3D technologies are deficient in many aspects, including low resolution and the requirement for complicated multi-camera setup and calibration, and special glasses. The advent of light field (LF) photography enables us to record light rays in a single shot and provide glasses-free 3D display with continuous motion parallax in a wide viewing zone, which is ideally suited for 3D telehealth applications. As far as our literature review suggests, there have been no reports of 3D telemedicine systems using LF technology. In this paper, we propose a cross-platform solution for a LF-based 3D telemedicine system. Firstly, a novel system architecture based on LF technology is established, which is able to capture the LF of a patient, and provide an immersive 3D display at the doctor site. For 3D modeling, we further propose an algorithm which is able to convert the captured LF to a 3D model with a high level of detail. For the software implementation on different platforms (i.e., desktop, web-based and mobile phone platforms), a cross-platform solution is proposed. Demo applications have been developed for 2D/3D video conferencing, 3D model display and edit, blood pressure and heart rate monitoring, and patient data viewing functions. The demo software can be extended to multi-discipline telehealth applications, such as tele-dentistry, tele-wound and tele-psychiatry. The proposed 3D telemedicine solution has the potential to revolutionize next-generation telemedicine technologies by providing a high quality immersive tele-consultation experience.

  2. Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.

    PubMed

    Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F

    2013-09-01

    The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.

  3. A new approach towards image based virtual 3D city modeling by using close range photogrammetry

    NASA Astrophysics Data System (ADS)

    Singh, S. P.; Jain, K.; Mandla, V. R.

    2014-05-01

    3D city model is a digital representation of the Earth's surface and it's related objects such as building, tree, vegetation, and some manmade feature belonging to urban area. The demand of 3D city modeling is increasing day to day for various engineering and non-engineering applications. Generally three main image based approaches are using for virtual 3D city models generation. In first approach, researchers used Sketch based modeling, second method is Procedural grammar based modeling and third approach is Close range photogrammetry based modeling. Literature study shows that till date, there is no complete solution available to create complete 3D city model by using images. These image based methods also have limitations This paper gives a new approach towards image based virtual 3D city modeling by using close range photogrammetry. This approach is divided into three sections. First, data acquisition process, second is 3D data processing, and third is data combination process. In data acquisition process, a multi-camera setup developed and used for video recording of an area. Image frames created from video data. Minimum required and suitable video image frame selected for 3D processing. In second section, based on close range photogrammetric principles and computer vision techniques, 3D model of area created. In third section, this 3D model exported to adding and merging of other pieces of large area. Scaling and alignment of 3D model was done. After applying the texturing and rendering on this model, a final photo-realistic textured 3D model created. This 3D model transferred into walk-through model or in movie form. Most of the processing steps are automatic. So this method is cost effective and less laborious. Accuracy of this model is good. For this research work, study area is the campus of department of civil engineering, Indian Institute of Technology, Roorkee. This campus acts as a prototype for city. Aerial photography is restricted in many country

  4. The Martian Water Cycle Based on 3-D Modeling

    NASA Technical Reports Server (NTRS)

    Houben, H.; Haberle, R. M.; Joshi, M. M.

    1999-01-01

    Understanding the distribution of Martian water is a major goal of the Mars Surveyor program. However, until the bulk of the data from